Y-Flow TCHEY-THHEY

Size: px
Start display at page:

Download "Y-Flow TCHEY-THHEY"

Transcription

1 Y-Flow TCHEY-THHEY Cooling capacity: kw - Heating capacity: kw Applications with well water, water mains or geothermal probes Integrated MASTER/SLAVE control HT65 version for 65 C water production ( ) ( ) Refer to the specific documentation to check available models and accessories. Web code: : YF : YF031 Reversible packaged heat pumps and water chillers on the cooling circuit with water-cooling. Range with hermetic scroll compressors and R410A refrigerant gas. Construction features Compressor: hermetic rotary scroll complete with thermal protection and crankcase heater. Primary side (user) heat exchanger: adequately insulated stainless steel plates, complete with antifreeze heater and water flow differential pressure switch. Disposal unit side (well/mains/geothermal probes) heat exchanger: adequately insulated stainless steel plates, complete with antifreeze heater and water flow differential pressure switch (for THHEY). Control: microprocessor electronic control with Adaptive Function Plus logic. Structure: made of galvanised and painted steel plate with polyester powder coating. The unit is also complete with: - compressor circuit breaker switches; - display of cooling circuit high and low pressure; - Master/Slave control up to 4 units in parallel; - clock board; V analogue signal for condensing/evaporating control performed by external device. Versions LT - Hot water production up to 52 C. HT - Hot water production up to 55 C. Models TCHEY: unit designed for cooling only. THHEY: heat pump unit. Factory fitted accessories PUMP primary side (user): with single or double electric pump, including an automatic pump in standby, complete with expansion tank, safety valve, water fill/drain valve, air vent valve and pressure gauge. The electric pumps are available in the low or high pressure head versions. PUMP disposal side (geothermal probes/dry cooler): with single or double electric pump regulated via inverter including an automatic actuation pump in standby. Desuperheater. 100% heat recovery unit (mod ). Water circuit heat pump (for TCHEY only). Power factor correction capacitors (cosφ > 0.94). Soft-starter. Energy parameter measuring device. Cooling circuit outlet and inlet valves. Refrigerant leak detector. Forced limit of power consumption. Electronic expansion valve (standard for mod ). Cooling circuit high and low pressure gauges. Double safety valves. Silenced set up. Control of min/max power supply voltage. Low temperature water production. Digital input for double set-point. 4-20mA analogue signal for shifting set-point. Interfaces for serial communication with other devices. Rubber anti-vibration mounts. Separately supplied accessories 3-way modulating condensing control valve. 2-way modulating condensing control valve. Outdoor air temperature probe for set-point compensation. Free-cooling kit (mod ). Water filter. Remote keypad with display. Thermostat with display. Serial converter (RS485/USB). Rhoss supervisors for unit monitoring and remote management. Rhoss sequencer for integrated management of multiple chillers.

2

3 Technical Data TCHEY MODEL ❶ Cooling capacity kw ,3 68,9 75,5 89,6 102,6 116,8 ❶ Absorbed power kw 9,85 11,42 13,19 15,01 16,52 19,27 22,55 25,55 ❶ E.E.R. 4,57 4,64 4,57 4,59 4,57 4,65 4,55 4,56 THHEY MODEL ❷ Heating capacity kw 50,2 59,1 67,9 75,7 84,1 102, ,9 ❷ Absorbed power kw 12, ,98 17,73 19,93 24,04 27,86 31,58 ❷ C.O.P. 4,1 4,22 4,25 4,27 4,22 4,26 4,2 4,24 ❶ Cooling capacity kw 41,2 48,5 55, ,1 81,9 95,7 109,1 ❶ E.E.R. 4,32 4,38 4,36 4,31 4,31 4,31 4,35 4,35 TCHEY - THHEY MODEL ❸ Sound power db(a) Scroll/step compressor no. 2/2 2/2 2/2 2/2 2/3 2/2 2/3 2/3 Circuits no Electrical supply V-ph-Hz N N N N N N N N-50 DIMENSIONS AND WEIGHTS ❹ L - Width mm ❺ L - Width mm H - Height mm P - Depth mm ❻ Weight TCHEY LT kg ❻ Weight TCHEY HT kg ❻ Weight THHEY LT kg ❻ Weight THHEY HT kg SEASONAL ENERGY IN COOLING MODE Pdesignc (EN 14825) kw 45,1 53,1 60, ,6 89,8 102, SEER (EN 14825) 5,68 5,82 5,91 5,83 6 5,85 5,81 5,97 2 ηs,c % IN COOLING MODE 1 Pdesignc (EN 14825) kw SEER (EN 14825) ηs,c % IN HEATING MODE 3 Pdesignh (EN 14825) kw SCOP (EN 14825) 6,48 6,53 6,42 6,4 6,68 6,32 6,37 6,34 4 ηs % Energy class A TCHEY MODEL ❶ Cooling capacity kw 130,5 145,1 164, ,6 206,5 232,2 259,8 ❶ Absorbed power kw 29 31,82 37,06 42,01 37,78 43,2 48,58 54,58 ❶ E.E.R. 4,5 4,56 4,45 4,38 4,78 4,78 4,78 4,76 THHEY MODEL ❷ Heating capacity kw 147,9 163,4 186,9 209,7 202, ,2 292,3 ❷ Absorbed power kw 35,47 39,56 45,92 52,29 45,95 53,35 60,85 68,45 ❷ C.O.P. 4,17 4,13 4,07 4,01 4,4 4,33 4,26 4,27 ❶ Cooling capacity kw 120,7 134,3 152,2 169,9 160,4 183,5 206,5 231,4 ❶ E.E.R. 4,3 4,29 4,08 4,02 4,42 4,29 4,22 4,19 TCHEY - THHEY MODEL ❸ Sound power db(a) Scroll/step compressor no. 2/3 2/2 2/3 2/2 4/4 4/4 4/4 4/4 Circuits no Electrical supply V-ph-Hz N N N N DIMENSIONS AND WEIGHTS ❹ L - Width mm ❺ L - Width mm H - Height mm P - Depth mm ❻ Weight TCHEY LT kg ❻ Weight TCHEY HT kg ❻ Weight THHEY LT kg ❻ Weight THHEY HT kg SEASONAL ENERGY

4 IN COOLING MODE 1 Pdesignc (EN 14825) kw 130,7 145,3 165,1 184,1 180,8 206,8 232,5 260,1 1 SEER (EN 14825) 5,91 5,88 5,97 5,72 5,75 5,93 6,11 6,12 2 ηs,c % IN COOLING MODE 1 Pdesignc (EN 14825) kw SEER (EN 14825) ηs,c % IN HEATING MODE 3 Pdesignh (EN 14825) kw SCOP (EN 14825) 6,13 6,05 6,13 5,84 6,87 6,63 6,49 6,47 4 ηs % Energy class TCHEY MODEL ❶ Cooling capacity kw 287,2 325,6 362,8 407,1 448,8 ❶ Absorbed power kw 60,46 69,72 79,39 90,87 103,17 ❶ E.E.R. 4,75 4,67 4,57 4,48 4,35 THHEY MODEL ❷ Heating capacity kw 323,9 369, ,4 515,5 ❷ Absorbed power kw 75,85 87,93 99,52 116,98 127,92 ❷ C.O.P. 4,27 4,2 4,16 3,97 4,03 ❶ Cooling capacity kw 255,2 292,7 330,1 373,9 412,9 ❶ E.E.R. 4,16 4,14 4,16 4,1 4,03 TCHEY - THHEY MODEL ❸ Sound power db(a) Scroll/step compressor no. 4/4 4/4 4/4 4/4 4/4 Circuits no Electrical supply V-ph-Hz DIMENSIONS AND WEIGHTS ❹ L - Width mm ❺ L - Width mm H - Height mm P - Depth mm ❻ Weight TCHEY LT kg ❻ Weight TCHEY HT kg ❻ Weight THHEY LT kg ❻ Weight THHEY HT kg SEASONAL ENERGY IN COOLING MODE Pdesignc (EN 14825) kw 287,4 325, , SEER (EN 14825) 6,1 6,03 5,93 6,02 5,92 2 ηs,c % IN COOLING MODE 1 Pdesignc (EN 14825) kw 255, , ,1 1 SEER (EN 14825) 5,82 5,79 5,88 5,51 5,91 2 ηs,c % IN HEATING MODE 3 Pdesignh (EN 14825) kw SCOP (EN 14825) ηs % Energy class ❶ Data at the following conditions: Chilled water: 12/7. - Condenser water: 30/35 C. ❷ Hot water: 40/45 C. - Evaporator water: 10/7. ❸ Total sound power level in db(a) based on measurements carried out in accordance with regulation UNI EN-ISO ❹ ❺ ❻ 1 Width referring to the unit with standard set up or supplied with "recovery" or "desuperheater" accessories. Width referring to the PUMP set up, up to a maximum of 2 pumps in mod (2 user side or disposal unit side pumps or 1 user side pump + 1 disposal unit side pump) and up to a maximum of 4 pumps in mod (2 pumps on user side and 2 pumps on disposal unit side). Empty weight Performance according to EN 14511:2018. Low temperature application (7 C) 2 Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281) 3 In Average climatic conditions, low temperature application (35 C)

5 4 Seasonal energy efficiency: low temperature heating in Average climate (EU Regulations No.811/2013 and No.813/2013) Rhoss s.p.a. Via Oltre Ferrovia Codroipo (UD) Tel Fax

technical catalogue tetris KW Chiller and heat pumps air/water

technical catalogue tetris KW Chiller and heat pumps air/water technical catalogue tetris 110 930 KW Chiller and heat pumps air/water > TETRIS Water chiller > TETRIS /HP Reversible heat pump > TETRIS /ST Water chiller with storage tank and pumps > TETRIS /DC Unit

More information

OMEGA V ECHOS Water/water cooled chillers and heat pumps kw

OMEGA V ECHOS Water/water cooled chillers and heat pumps kw Water/water cooled chillers and heat pumps 172 1527 kw General information Water-cooled water chillers with hermetic screw compressors and tube bundle heat exchangers. Designed for installation indoors.

More information

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS Air/water chillers and heat pumps LSE Outdoor packaged unit LSE 60-00 kw Multi-scroll solutions for reliability and high efficiency at partial loads Scroll compressor PLUS R-0A R-0A refrigerant Cooling

More information

WQL/WQH/WQRC 524 to 1204

WQL/WQH/WQRC 524 to 1204 Chiller / Close control / Water terminals WQL/WQH/WQRC 524 to 1204 Water Cooled Water Chillers Cooling Only, Heat Pump and Condenserless Versions Engineering Data Manual 155 to 30 kw 170 to 370 kw Features

More information

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75. Chiller AQL/ to 75 Air Cooled Water Chillers Only and Heat Pump Engineering Data Manual.0 to 75.8 kw 39.9 to 77.2 kw Outstanding Strength Points R410A Refrigerant. New simpler refrigerant circuit layout.

More information

ENR Incorporating

ENR Incorporating ENR 002-480 Incorporating R410A Refrigerant Air cooled water chillers with scroll compressors and axial fans, 2.2-480kW ENR 002-100 models inc. self-cleaning coaxial evaporators ENR 130-480 models inc.

More information

Flex Series. Modular Air-cooled Chillers and Heat Pumps Cooling Capacity kw Heating Capacity kw

Flex Series. Modular Air-cooled Chillers and Heat Pumps Cooling Capacity kw Heating Capacity kw Flex Series Modular Air-cooled Chillers and Heat Pumps Cooling Capacity 38-329 kw Heating Capacity 47-354 kw 1 Trane Flex Series Modular air/water chillers and heat pumps units with axial fans and scroll

More information

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw TWA 212-1102 S/K/P Incorporating R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw The complete solution to all your cooling needs TWA 212-1102 S/K/P Index

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

AZURA. Air/water multifunctional chiller&heat pump, kw

AZURA. Air/water multifunctional chiller&heat pump, kw AZURA STM Air/water multifunctional chiller&heat pump, 31-211 kw General Air/water unit with indipendent production of chilled water and hot water equipped with axial fans and hermetic scroll compressors.

More information

Engineering Data Book

Engineering Data Book Engineering Data Book Contents Specifications 2 Dimensions of Indoor 3 and outdoor units Indoor unit Outdoor unit Wiring diagrams 6 RAS-05BKV-E RAS-07BKV-E RAS-05BAV-E RAS-07BAV-E Sensible capacity table

More information

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07. Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water

More information

CATÁLOGO TÉCNICO COMERCIAL

CATÁLOGO TÉCNICO COMERCIAL CATÁLOGO TÉCNICO COMERCIAL ENFRIADORAS DE AGUA CONDENSADAS POR AIRE Series LCAEX De 350 a 1600 Kw. Compresor de tornillo R-134A Index Identification code Identification code and index... pag. 2 General

More information

ZETA ECHOS. Chillers and heat pumps Air/water kw. General Air/Water chillers and heat pumps with axial fans and hermetic scroll compressors.

ZETA ECHOS. Chillers and heat pumps Air/water kw. General Air/Water chillers and heat pumps with axial fans and hermetic scroll compressors. Chillers and heat pumps Air/water 41 125 kw General Air/Water chillers and heat pumps with axial fans and hermetic scroll compressors. Versions A: Energy efficient class A HP. Reversible heating LE: Without

More information

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version)

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version) R u Air Cooled Water Chillers VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version) Models 524 to 1204 137 to 308 kw 150 to 336 kw Engineering Data Manual EDM VL410-W.2GB Date :

More information

DIMENSION AND SELECTION GUIDE

DIMENSION AND SELECTION GUIDE WW-SERIES WATER-TO-WATER UNITS DIMENSION AND SELECTION GUIDE RATED IN ACCORDANCE TO ISO STANDARD 13256-2:1998. MODEL DESIGNATION WW SERIES R 120 MODEL R= REVERSE CYCLE B 0 0 0 3 B EVAPORATOR SIZE CABINET

More information

CWP-CO / CWP-RC / CWP-HP 02 to 35

CWP-CO / CWP-RC / CWP-HP 02 to 35 Water Cooled Water Chillers Cooling Only, Condenserless and Heat Pump Versions - / - / - 02 to 35 8 to 136 9 to 164 Technical Brochure TM -N.4GB Date : March 2006 Supersedes : TM -N.3GB/05.04 Technical

More information

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment Screw compressors CIAT shell and tubes direct expansion evaporator (High Power System) equipment Cooling capacity: 370 to 1 170 kw Heating capacity: 500 to 1 400 kw Heating Cooling Heat recovery Use The

More information

AQWL/AQWH/AQWR 1404 to 2406

AQWL/AQWH/AQWR 1404 to 2406 Chiller AQWL/AQWH/AQWR 1404 to 2406 Air Cooled Water Chillers Only, Heat Pump and Total Heat Recovery Engineering Data Manual 380 to 634 kw 418 to 702 kw Features & Strength Points A more "slim and light"

More information

Chiller. AQSL 2612 to Air Cooled Chillers With or without total heat recovery Engineering Data Manual. 602 to 908 kw

Chiller. AQSL 2612 to Air Cooled Chillers With or without total heat recovery Engineering Data Manual. 602 to 908 kw Chiller AQSL 2612 to 4212 Air Cooled Chillers With or without total heat recovery Engineering Data Manual 602 to 908 kw Features & Strength Points Sturdy structure, vibration tests and FEM structural analysis.

More information

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual. Chiller SWS/SWR 1602 to 4802 Water Cooled Chillers Only and Condenserless Versions Engineering Data Manual 272 to 1118 kw Specifications General The SWS water cooled screw chillers are equipped with high

More information

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C) Simple, reliable efficient heat pump! Equipped with µconnect controller HFC R410A CERTITA CERTIFIED * Cooling capacity: 5 to 16.5 kw Heating capacity: 6 to 19 kw *except 75HT OPTION HEAT PUMP HEATING (30/35

More information

TEAL FCTM. Chiller with integrated Free Cooling system chillers and heat pumps, kw

TEAL FCTM. Chiller with integrated Free Cooling system chillers and heat pumps, kw TM Chiller with integrated Free Cooling system chillers and heat pumps, 100-530 kw General The TEAL FC range, with scroll compressors and free cooling system, uses the ecofriendly R410A refrigerant and

More information

AQVL (Cooling Only Version) AQVH (Heat Pump Version)

AQVL (Cooling Only Version) AQVH (Heat Pump Version) R u Air Cooled Water Chillers (Cooling Only Version) (Heat ump Version) Models 85 to 140 84 to 137 kw 92 to 146 kw Engineering Data Manual EDM AQV-W.1GB Date : November 2009 Supersedes : None High erformance

More information

Reversible air-to-water scroll heat pumps

Reversible air-to-water scroll heat pumps Reversible air-to-water scroll heat pumps Model CXAO 120 to 290 Cooling capacity: 420-1030 kw Heating capacity: 475-1175 kw CG-PRC027A-GB Table of Contents Model number description...4 Technical specifications...5

More information

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

HYDROCIAT LW R134a. Water cooled chillers USE RANGE Screw compressors CIAT direct expansion shell and tubes evaporator equipment (High Power System) Cooling or heating Heat recovery ENVIRONMENTALLY HFC R134a PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling

More information

Air cooled chillers With axial fans and power ratings from 238 to 1600 kw with two-screw compressor

Air cooled chillers With axial fans and power ratings from 238 to 1600 kw with two-screw compressor NS Air cooled chillers With axial fans and power ratings from 238 to 1600 kw with two-screw compressor R134a Aermec adhere to the EUROVENT Certification program up to 600 kw. The products concerned appear

More information

Multi-pipe units with scroll compressors

Multi-pipe units with scroll compressors Multi-pipe units with scroll compressors Model CMAB SE 050-525 Model CMAB HE 050-880 Cooling capacity: 45-779 kw Heating capacity: 49-881 kw CG-PRC044A-GB Table of Contents Product presentation...4 Operating

More information

AQVSL/AQVSH STAR 85 to 140

AQVSL/AQVSH STAR 85 to 140 Chiller QVSL/ STR 85 to 140 ir Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual 82 to 157 kw 83 to 168 kw Outstanding Strength Points Units with R410 refrigerant (it will be the

More information

RANGE. STD Version (Standard): HEE Version (High Energy Efficiency): OPERATION LIMITS. Series LP 46ºC 12ºC 18ºC 5ºC

RANGE. STD Version (Standard): HEE Version (High Energy Efficiency): OPERATION LIMITS. Series LP 46ºC 12ºC 18ºC 5ºC Cooling capacity: Heating capacity: 17,7 to 74,3 kw 21,8 to 84,8 kw Scroll compressors R-410A refrigerant Compact and silent design Cooling solution where an outdoor installation is impossible DESCRIPTION

More information

CGAM. Air-cooled scroll chiller. Accessories. Customer benefits. Tracer CH530 Control. Main features. Energy saving options.

CGAM. Air-cooled scroll chiller. Accessories. Customer benefits. Tracer CH530 Control. Main features. Energy saving options. CGAM Air-cooled scroll chiller Customer benefits Life cycle effectiveness Efficiency and sound level without compromise All year round operation Extreme reliability and durability Wide application flexibility

More information

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features

More information

OMICRON V EVO. Multifunctional unit

OMICRON V EVO. Multifunctional unit Multifunctional unit 231 773 General Air/water unit with indipendent production of chilled water and hot water equipped with axial fans and semihermetic screw compressors. Production of hot water up to

More information

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 330 to 500 kw Heating capacity: 340 to 500 kw Cooling

More information

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM 1 Lmf Clima 216 FERRARO GROUP HPR Heat recovery units HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM from 7 to 23. m³/h Supporting structure in extruded aluminium profiles and curtain

More information

CXAM. Options. Accessories

CXAM. Options. Accessories CXAM Reversible air-to-water scroll heat pump Customer benefits Life cycle effectiveness Efficiency and sound level without compromise All year round operation Extreme reliability and durability Wide application

More information

AHN 064 to 304 EHN/CHN 064 to 304

AHN 064 to 304 EHN/CHN 064 to 304 u Horizontal Packaged and Split Air Conditioners AHN 64 to 34 EHN/CHN 64 to 34 6. to 29.2 kw 6.4 to 29.4 kw Engineering Data Manual EDM AECHN-A.1GB Date : June 28 Supersedes : None Technical Description

More information

Epsilon Echos DK kw

Epsilon Echos DK kw silon Echos DK 5 38 kw EPSILON ECHOS DK is the range of chillers and ductable air-water heat pumps. In its standard equipment, the unit is equipped with high pressure axial fans (up to a useful 100Pa),

More information

Air/Water chillers for outdoor installation Screw compressors, shell and tube heat exchangers and axial fans Cooling capacity kW 1402/9603

Air/Water chillers for outdoor installation Screw compressors, shell and tube heat exchangers and axial fans Cooling capacity kW 1402/9603 NEW NSM ir/water chillers for outdoor instation Screw compressors, shell and tube heat exchangers and axial fans ooling capacity 302 2100kW 1402/9603 cooling only R134a ermec participate in the EUROVENT

More information

YCZ HIGH WALL RESIDENTIAL MULTISPLIT DUO/TRIO/QUATTRO/CINCO

YCZ HIGH WALL RESIDENTIAL MULTISPLIT DUO/TRIO/QUATTRO/CINCO YCZ RESIDENTIAL MULTISPLIT DUO/TRIO/QUATTRO/CINCO q Multi line available in four capacities from 5.2 up to 10.5 kw. q DC Inverter and sine wave compressor drive technology. q Match with high wall, ducted,

More information

Air-Cooled Liquid Chiller with integrated hydraulic module

Air-Cooled Liquid Chiller with integrated hydraulic module Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800

More information

NECS-WQ. Climaveneta Technical Bulletin NECS_WQ_0152_1604_201006_GB. INTEGRA unit for 4-pipe systems, water source ,6-522 kw

NECS-WQ. Climaveneta Technical Bulletin NECS_WQ_0152_1604_201006_GB. INTEGRA unit for 4-pipe systems, water source ,6-522 kw Climaveneta Technical Bulletin NECS_WQ_0152_1604_201006_GB r HFC R-410A 0152-1604 48,6-522 kw INTEGRA unit for 4-pipe systems, water source (The photo of the unit is indicative and may change depending

More information

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW Compresseur scroll Refrigerant R410A SYSAQUAC Air Cooled Condensing Units Models 25 to 125 32.0 to 136.0kW SYSAQUA Condensation 1 Key Points R410A refrigerant, Units are optimized for partial load operation,

More information

YAZE. Multisplit DCI - C BMS. q Capacity range available in 4 capacities from 5 up to 9.5 kw. q DC Inverter and sine wave compressor drive technology.

YAZE. Multisplit DCI - C BMS. q Capacity range available in 4 capacities from 5 up to 9.5 kw. q DC Inverter and sine wave compressor drive technology. YAZE q Capacity range available in 4 capacities from 5 up to 9.5 kw. q DC and sine wave compressor drive technology. PRODUCT ADVANTAGES Flexy match wide range of indoor unit including HJD, SXE, CNE, DLS,

More information

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105 TECHNICAL CATALOGUE WPHA Cooling only WPHBA Heat pump Models 091, 121, 141, 171, 201, 251, 351, 401, 501, 701, 751, 1001, 1201 Cooling capacities from 2,4 kw to 41 kw Heating capacities from 2,8 kw to

More information

CWP. Cooling Only Version (CO) Condenserless Version (RC) Heat Pump Version (HP) Models 02 to 35. Engineering Data Manual. Water Cooled Water Chillers

CWP. Cooling Only Version (CO) Condenserless Version (RC) Heat Pump Version (HP) Models 02 to 35. Engineering Data Manual. Water Cooled Water Chillers Engineering Data Manual Water Cooled Water Chillers Cooling Only Version () Condenserless Version () Heat Pump Version () Models 02 to 35 8 to 136 9 to 164 N IRWELL GROUP MPNY Specifications General The

More information

Conditioning your ambient, maximising your comfort.

Conditioning your ambient, maximising your comfort. High efficiency water cooled chillers, heat pumps and evaporating units with screw compressors and R134a refrigerant gas. Cooling capacity 380 1549 kw Heating capacity 427 1740 kw Cooling capacity condenserless

More information

TEAL FC. Chiller with integrated Free Cooling system kw

TEAL FC. Chiller with integrated Free Cooling system kw TEAL FC Chiller with integrated Free Cooling system 100 530 kw General The TEAL FC range, with scroll compressors and free cooling system, uses the ecofriendly R410A refrigerant. Substantial energy saving,

More information

UMXCA/UMXCBA ECVA/ECVBA

UMXCA/UMXCBA ECVA/ECVBA OUTDOOR UNITS Models: 801.1 1001.1 1201.1 1501.1 1602.2 2002.2 2402.2 3002.2 3502.2 4002.2 4502.2 Cooling Capacities: from 25,9 kw to 134,7 kw Heating Capacities: from 27,3 kw to 142,4 kw INDOOR UNITS

More information

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw Chiller VLC 524 to 1204 Air Cooled Condensing Units Engineering Data Manual 154 to 347 kw Outstanding Strength Points Units with R410A refrigerant (it will be the real replacement of R22). As near azeotropic

More information

NSM. R134a NEW HIGH EFFICIENCY ALSO AT PARTIAL LOADS ENERGY SAVING MICRO-CHANNEL COIL QUICK AND EASY INSTALLATION NIGHT MODE.

NSM. R134a NEW HIGH EFFICIENCY ALSO AT PARTIAL LOADS ENERGY SAVING MICRO-CHANNEL COIL QUICK AND EASY INSTALLATION NIGHT MODE. NEW NSM ir/water chillers for outdoor installation with free cooling Screw compressors, shell and tube heat exchangers and axial fans from 306 2028kW 1402/9603 free cooling R134a HIGH EFFIIENY LSO T PRTIL

More information

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL 1.1 SUMMARY A. Packaged Chillers offer a self-contained means of producing cooling liquid primarily

More information

Bosch BOVA Split System Heat Pump

Bosch BOVA Split System Heat Pump Bosch BOVA Split System Heat Pump Condensing Units Up to 18 SEER 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BOVA Product Specifications Data subject to change 03.2018 Bosch Thermotechnology

More information

NECS-N. Climaveneta Technical Bulletin NECS_N_1314_3218_201003_GB. Air-to-water reversible heat pump with axial fans kw

NECS-N. Climaveneta Technical Bulletin NECS_N_1314_3218_201003_GB. Air-to-water reversible heat pump with axial fans kw Climaveneta Technical Bulletin NECS_N_1314_3218_201003_GB r HFC R-410A 1314-3218 339-792 kw Air-to-water reversible heat pump with axial fans (The photo of the unit is indicative and may change depending

More information

Models: 12 and 18. Models: 24 to 60

Models: 12 and 18. Models: 24 to 60 SPLIT CASSETTE TYPE MUCSR-H8 Series SCOP 4.0 Models: 12 and 18 RG57B2/BGE Included (CL 94 982) Models: 24 to 60 Design 360 Thanks to the 360 panel design, the air is more evenly distributed. Drainage pump

More information

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING 199 RE ER RS SO AIR COOLED HEAT PUMP LIQUID CHILLERS 19,1 261,0 kw COOLING 23,7 333,0 kw HEATING R410A PLATE RCGROUP SpA 19632013 fiftycoolyears 200 VERSIONS: (R410A) Cooling capacity 19,2 261,0 kw Heating

More information

R134a Water Cooled Chillers. WCWWXT/Y Series ( Ton)

R134a Water Cooled Chillers. WCWWXT/Y Series ( Ton) R134a Water Cooled Chillers WCWWXT/Y Series (76-703 Ton) 1 INDEX Page General description 3 Versions 3 Technical features 3 Factory fitted accessories 3 Loose accessories 3 Reference conditions 3 Operating

More information

CGA CXA VGA VXA CG-PRC006-E4

CGA CXA VGA VXA CG-PRC006-E4 Cooling Only or Reversible Air Cooled Water Chiller CGA 075-100-120-150-200-240 CXA 075-100-120-150-200-240 VGA 075-100-120-150-200-240 VXA 075-100-120-150-200-240 Designed with your needs in mind TRANE

More information

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10 Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19

More information

HWT 1402/9603. free cooling

HWT 1402/9603. free cooling irwater chillers for outdoor installation with free cooling Screw compressors, shell and tube heat exchangers and axial fans NSM Cooling capacity 306-2001kW HWT 14029603 free cooling HIGH EFFICIENCY LSO

More information

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS.

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS. User manual Manual version: 2.4 dated 27/02/08 Program code: FLSTDmMCDE LEGGI

More information

NSM. R134a HIGH EFFICIENCY ALSO AT PARTIAL LOADS ENERGY SAVING MICRO-CHANNEL COIL QUICK AND EASY INSTALLATION NIGHT MODE.

NSM. R134a HIGH EFFICIENCY ALSO AT PARTIAL LOADS ENERGY SAVING MICRO-CHANNEL COIL QUICK AND EASY INSTALLATION NIGHT MODE. NSM ir/water chillers for outdoor installation with free cooling glycol free Screw compressors, shell and tube heat exchangers and axial fans from 306 2028kW 1402/9603 glycol free R134a HIGH EFFIIENY LSO

More information

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA 1 of 10 Mattei rotary vane compressors are the result of 90 years of investments in research and development to improve performance and lessen the impact on the environment. Designed for industrial continuous

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

LHA LHA A ++ High efficiency air to water heat pumps EVI EVI EVI DC. Versions

LHA LHA A ++ High efficiency air to water heat pumps EVI EVI EVI DC. Versions LH High efficiency air to water heat pumps ++ Inverter LH -20 C Inverter +43 C Inverter 20 EVI +60 C Inverter DC INVERTER +58 C EVI +65 C COP 4,1 EVI DC INVERTER EVI DC INVERTER DC COP 4,1 INVERTER COP

More information

VHA. Air cooled chiller with

VHA. Air cooled chiller with TECHNICAL Data Sheet Air cooled chiller with SCROLL OR RECIPROCATING compressors and axial fans for outdoor installation V Range 19-1196 kw Range Air cooled chiller with scroll or reciprocating compressors

More information

30XW- 30XWH. Water-Cooled Liquid Chillers. Nominal cooling capacity kw Nominal heating capacity kw

30XW- 30XWH. Water-Cooled Liquid Chillers. Nominal cooling capacity kw Nominal heating capacity kw Water-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com 30XW- 30XWH Nominal cooling capacity 278-1756 Nominal heating capacity 322-1989 The 30XW liquid chillers are the premium solution

More information

CHILLER START UP PROCEDURE FORM DOC. N (DOC.N BELOW TO BE RETURN TO AERMEC)

CHILLER START UP PROCEDURE FORM DOC. N (DOC.N BELOW TO BE RETURN TO AERMEC) CHILLER START UP PROCEDURE FORM DOC. N 061103 (DOC.N 071103 BELOW TO BE RETURN TO AERMEC) 1. Preliminary Operation WARNING: The following operation must be done without the power supply (unit with the

More information

Bosch BOVA Split System Heat Pump

Bosch BOVA Split System Heat Pump Bosch BOVA Split System Heat Pump Condensing Units Up to 18 SEER 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BOVA Product Specifications Data subject to change 06.2016 Bosch Thermotechnology

More information

FOCS. Climaveneta Technical Bulletin. Air-cooled water chiller with helical fans kw

FOCS. Climaveneta Technical Bulletin. Air-cooled water chiller with helical fans kw Climaveneta Technical Bulletin _1542_242_200909_GB 1542-242 277-51 kw Air-cooled water chiller with helical fans (The photo of the unit is indicative and may change depending on the model) Flexibility

More information

RECU-NOVO. heat recovery unit

RECU-NOVO. heat recovery unit heat recovery unit // CHARACTERISTICS heat recovery units are suitable for residential and commercial applications. Characteristics Fully removable panels (sandwich type). Acoustic and thermal panel insulation:

More information

Bosch Climate 5000 Ductless Minisplit System

Bosch Climate 5000 Ductless Minisplit System Engineering Submittal Sheet Overview and Certifications [single zone only] Standard Features and Field Installed Accessories Standard Features R-410A chlorine-free refrigerant with pre-charge for line

More information

LDA LDA. Air cooled water chillers with axial fans VERSIONS R410A

LDA LDA. Air cooled water chillers with axial fans VERSIONS R410A LD ir cooled water chillers with axial fans R410 222 LD LD water chillers are efficient, low-noise products designed for medium to large applications. They are suitable for generating chilled water at

More information

... RTU Technical Manual. Packaged Air Conditioning Unit...

... RTU Technical Manual. Packaged Air Conditioning Unit... ... RTU Technical Manual Packaged Air Conditioning Unit... Index. CODING AND MODELS. WORKING LIMITS. TECHNICAL SPECIFICATIONS. PERFORMANCE TABLES. TECHNICAL SPECIFICATIONS FOR OPTIONAL EQUIPMENT. ELECTRONIC

More information

Residential multisplit Duo/Trio/Quattro/Cinco DC Inverter

Residential multisplit Duo/Trio/Quattro/Cinco DC Inverter YCZ Residential multisplit Duo/Trio/Quattro/Cinco DC Depending on combination HKD COMPATIBLE WITH HND CBD DCD A ++ XAD 2016 YCZ Residential multisplit Duo/Trio/Quattro/Cinco DC COMPATIBLE WITH HIGH WALL

More information

Inverter scroll compressors VZH single and manifold

Inverter scroll compressors VZH single and manifold Application guidelines Inverter scroll compressors VZH088-117-170 single and manifold R410A http://cc.danfoss.com Content VZH088-117-170 - single compressors... 4 VZH088-117-170 - hybrid manifolding...

More information

30GX AIR-COOLED LIQUID CHILLER

30GX AIR-COOLED LIQUID CHILLER 30GX-4SB 30GX080-265 AIR-COOLED LIQUID CHILLER PERFORMANCE DATA FIELD WIRING DIAGRAM 1997 Carrier Corporation Syracuse, New York 13221 Form 30GX-4SB Supersedes 30GX-3SB Printed in U.S.A. 12-97 Catalog

More information

30GX AIR-COOLED LIQUID CHILLER

30GX AIR-COOLED LIQUID CHILLER 30GX-5SB 30GX080-265 AIR-COOLED LIQUID CHILLER PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GX-5SB Supersedes 30GX-4SB Printed in U.S.A. 5-98 Catalog No.

More information

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP VEP075N432K Job Name: Location: Schedule No.: System Designation: Engineer: Architect: Date: For: Reference Approval Review Construction FEATURES Two-pipe heat pump Hinged electrical box for ease of maintenance

More information

Unit Report For CH-1 30RB070 Project: UNF Soccer Stadium 04/21/2017

Unit Report For CH-1 30RB070 Project: UNF Soccer Stadium 04/21/2017 Unit Report For CH-1 30RB070 Unit Information Tag Name: CH-1 30RB070 Model Number: 30RB070 Condenser Type: Air Cooled Compressor Type: Scroll Nameplate Voltage: 460-3-60 V-Ph-Hz Quantity: 1 Manufacturing

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

ZETA REV series kw. General Customisable, high efficiency chiller and air/water heat pump, with hermetic scroll compressors.

ZETA REV series kw. General Customisable, high efficiency chiller and air/water heat pump, with hermetic scroll compressors. series 40 240 kw General Customisable, high efficiency chiller and air/water heat pump, with hermetic scroll compressors. Configurations HE: high efficiency HP: Reversible heat pump SLN: Super low noise

More information

Product Data. Features/Benefits. 30GUN,GUR Air-Cooled Reciprocating Liquid Chillers (HFC-134a) with ComfortLink Controls 50/60 Hz

Product Data. Features/Benefits. 30GUN,GUR Air-Cooled Reciprocating Liquid Chillers (HFC-134a) with ComfortLink Controls 50/60 Hz Product Data 30GUN,GUR Air-Cooled Reciprocating Liquid Chillers (HFC-134a) with ComfortLink Controls 50/60 Hz Nominal Capacities: 25 to 280 Tons 88 to 985 kw Features/Benefits ComfortLink control Your

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

30XW- 30XWH. Water-Cooled Liquid Chillers. Nominal cooling capacity kw Nominal heating capacity kw. Features and advantages

30XW- 30XWH. Water-Cooled Liquid Chillers. Nominal cooling capacity kw Nominal heating capacity kw. Features and advantages Water-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com 30XW- 30XWH Nominal cooling capacity 275-1765 kw Nominal heating capacity 320-1875 kw The 30XW liquid chillers are the premium

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

Air Master BCP. Pool air handling units. Optimized energy consumption Electronic control. Description. Principle schemes

Air Master BCP. Pool air handling units. Optimized energy consumption Electronic control. Description. Principle schemes Cooling capacity: Heating capacity: 92,1 to 179,9 kw 69, to 148,7 kw Heating and dehumidification of covered pools Optimized energy consumption Electronic control Description Principle schemes The range

More information

Product Data. S Two-stage scroll compressor S Used with variable speed fan coil or furnace coil Control

Product Data. S Two-stage scroll compressor S Used with variable speed fan coil or furnace coil Control GS Performance Series Geothermal Split Heat Pump Sizes 024, 036, 048, 0, 072 Product Data FEATURES & BENEFITS Energy Efficiency S 3.4-4.5 COP, 15.4-26.4 EER (Closed Loop) S 3.9-5.1 COP, 19.2-30.5 EER (Open

More information

McQuay International WMC New Water Cooled Chiller with oil free centrifugal compressors

McQuay International WMC New Water Cooled Chiller with oil free centrifugal compressors McQuay International WMC New Water Cooled Chiller with oil free centrifugal compressors Applied Systems - Strategic Marketing Contents 1. Introducing WMC 1.1 Product Overview 2010 1.2 Range 2. Technical

More information

TSE Series Central Chillers

TSE Series Central Chillers TSE Series Central s Dual Circuit Manifolds Included Dual circuit chillers include evaporator supply and return manifolds and water-cooled condenser units include condenser water supply and return manifolds

More information

VTZ variable speed Reciprocating compressors

VTZ variable speed Reciprocating compressors MAKING MODERN LIVING POSSIBLE Application guidelines VTZ variable speed Reciprocating compressors R404A, R507, R407C, R134a www.danfoss.com CONTENT VARIABLE SPEED COMPRESSORS... 4 Speed control...4 Advantages

More information

Product Catalog TSE Series Scroll Central Chillers

Product Catalog TSE Series Scroll Central Chillers Product Catalog TSE Series Scroll Central Chillers Contents Features...1 Available Options...3 Hot Gas Bypass Valve... 3 Rotary Non-Fused Disconnect Switch... 3 Integral Reservoir and Pumping System...

More information

Product Catalog TSE Series Scroll Central Chillers

Product Catalog TSE Series Scroll Central Chillers Product Catalog TSE Series Scroll Central Chillers Contents Features...1 Hot Gas Bypass Valve... 2 Rotary Non-Fused Disconnect Switch... 2 Integral Reservoir and Pumping System... 3 Remote Condenser Coil

More information

PACKAGED LIQUID CHILLER 6. HUMIDIFIER SECTIONS. C Member. Liquid Chiller. nowlc And noalc Series

PACKAGED LIQUID CHILLER 6. HUMIDIFIER SECTIONS. C Member. Liquid Chiller. nowlc And noalc Series 6. HUMIDIFIER SECTIONS Liquid Chiller nowlc And noalc Series C Member 1 Features and Benefits OMRAN cold generator reciprocating Liquid chiller are designed and built to provide reliable,efficient performance

More information

Water Source Heat Pump P 34 P 35. Features. Optional. Instruction of model. Water-Cooled Screw Chiller

Water Source Heat Pump P 34 P 35. Features. Optional. Instruction of model. Water-Cooled Screw Chiller Source Heat Pump -Cooled Screw Chiller R410a Product type LSSR10 LSSR14 LSSR16 LSSR20 LSSR28 Rated cooling capacity kw/btu/h 10.5 35836.5 14 47782 15.5 52902 21 71673 28 95564 Rated heating capacity kw/btu/h

More information

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons Product Catalog NQ Series Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons Page Intentionally Blank Contents Standard Features...1 Available Options...3 Oversized Pumps... 3 High Flow Unit

More information

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP) PRAMAC GBW 45 Item code: SB450TPAY00 Main features Standby : 36 kw power LTP Rated prime : 34 kw power (PRP) Rated : kw continuous power (COP) Phases : 3 Voltage : 400 V Frequency : 50 Hz Engine : Perkins

More information

PART 1 GENERAL. Pfannenberg Inc.

PART 1 GENERAL. Pfannenberg Inc. PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES DTS COOLING UNITS FOR SIDE MOUNTING/DOOR MOUNTING TO ELECTRICAL ENCLOSURES AND INDUSTRIAL CONTROL PANELS PART 1 GENERAL 1.1 SUMMARY A. Cooling

More information

High efficiency industrial type semi-hermetic twin helical screw compressor.

High efficiency industrial type semi-hermetic twin helical screw compressor. YCAS AIR COOLED SCREW CHILLER R407C REFRIGERANT COOLING CAPACITIES 260 kw to 1194 kw The YCAS range of chillers are designed for water or water-glycol cooling. Models are available with 2, 3 and 4 refrigerant

More information

Air-Cooled Screw Chillers RTAF kw. The best bundled in one. Our best.

Air-Cooled Screw Chillers RTAF kw. The best bundled in one. Our best. Air-Cooled Screw Chillers RTAF 300-2090 kw The best bundled in one. Our best. 1 The total package Quality, performance and reliability The Trane advantage Trane is recognized as a world leader with over

More information