1 technical catalogue tetris KW Chiller and heat pumps air/water

2

3 > TETRIS Water chiller > TETRIS /HP Reversible heat pump > TETRIS /ST Water chiller with storage tank and pumps > TETRIS /DC Unit with heat recovery condenser > TETRIS /DS Unit with desuperheaters > TETRIS /LN Low noise version > TETRIS /SLN Super low noise version

4 4 Technical Catalogue Tetris

5 index Technical Characteristics 04 Technical data standard unit 11 Electrical data standard unit 15 Tetris - Cooling capacity 17 Tetris /HP - Cooling capacity 21 Tetris /HP - Heating capacity 25 Operating limits 29 Sound level 30 Overall dimensions, 33 weights, clearances and hydraulic connections Installations recommendations 63 Tetris 5

6 TECHNICAL CHARACTERISTICS TETRIS Water chiller Compact-size air-cooled water chiller with hermetic scroll compressors, axial fans and plate evaporators. Refrigerant R410A. UNIT FRAME Modular, galvanized sheet structure with self-supporting frame, with bakedon polyester-powder coating (colour RAL 5014) providing excellent weather resistance. Stainless-steel threaded fasteners. COMPRESSORS Hermetic orbiting scroll compressors, connected in parallel, equipped with oil sight glass, internal Klixon thermal circuit-breaker, contactors and oil-equalizing line. CONDENSERS Finned-coil heat exchanger with copper tubes and aluminium fins. The coils V-shaped arrangement allows smaller unit size while increasing the air suction area and leaving more room for the components of the refrigerant circuit and hydraulic circuit, if present. The refrigerant circuits condensing sections work independently. ELECTRIC FANS Axial fans with sickle-shaped blades and manifold, designed to improve performance and reduce noise, directly coupled to 6-pole three-phase electric motor, with internal Klixon thermal circuit-breaker. Motor protection rating IP 54. The fan comes supplied with a safety grid. EVAPORATOR AISI 316 stainless-steel braze-welded plate evaporator, housed inside a closedcell insulating casing. Models with 2 refrigerant circuits are equipped with a 2-circuit exchanger having a single hydraulic coupling, while models with 4 refrigerant circuits are equipped with a double 2-circuit exchanger and hydraulic couplings with manifolds. Using 2-circuit plate-type heat exchangers presents the following advantages: Higher COP/EER values; Smaller amount of refrigerant in the circuit; Smaller unit size and weight; Easier maintenance; Each evaporator is equipped with a temperature probe for antifreeze protection. The hydraulic manifold is provided with a flow switch and a probe for measuring the temperature of the return water flow. REFRIGERANT CIRCUIT Includes: liquid line cut-off valve, 5/16 charge couplings, liquid-level sight glass, replaceable solid-core filter-dryer, electronic expansion valve. Models with 2 compressors (from 10.2 to 16.2) are equipped with high and lowpressure gauges and safety valves. Models with 3 to 12 compressors (from 20.3 to 93.12) are equipped with pressure transducers for checking high and low pressure values and the relative evaporation and condensation temperatures, high-pressure gauges and safety valves. The electronic expansion valve acts as a solenoid valve on the liquid line: it closes when the circuit is stopped, cutting off the liquid s flow. On request, the electronic valve can be equipped with a buffer battery so that it closes even during power failures. 6 Technical Catalogue Tetris

7 POWER PANEL The power panel includes: Main switch; Protection fuses on the auxiliary circuits and power circuits; Fan contactors; Thermomagnetic circuit-breakers for pumps (if present); A microprocessor controlling the following functions: - Regulation of inlet water temperature; - Antifreeze protection; - Compressor timing; - Automatic rotation of compressor starting sequence; - Alarms; - Alarm reset; - Setting the unit s capacity steps; - Common alarm contact for remote warning; - Forced steps at pressure limits; - Alarm log recording ( black box function) (only on sizes from 20.3 to 93.12); Information shown on display: - Inlet water temperature; - Temperature and differential settings; - Explanation of alarms; - Compressor working hours counter - Number of unit start-ups and pump start-ups counter, (if present) (only on sizes from 20.3 to 93.12); - High and low pressures and relative condensation and evaporation temperatures (only on sizes from 20.3 to 93.12). Power supply [V/f/Hz]: 400/3~/50 ±5%. Sizes from 50.7 to are equipped with two power panels, each with its own power supply. CONTROLS AND SAFETY DEVICES Manually resettable high pressure gauge; High pressure safety gauge, automatically reset at control-operated limited intervals; Low pressure safety gauge, automatically reset at control-operated limited intervals; High pressure safety valve; Antifreeze probe on each evaporator outlet; Chilled water temperature probe (located at evaporator discharge); Mechanical vane-operated flow switch, supplied installed; Compressor and fan overtemperature protection. Tetris TESTING All units are factory tested and supplied complete with oil and refrigerant charge. 7

8 VERSIONS Refer to the configurations table to check for possible incompatibility between options. TETRIS /HP: Reversible heat pump In addition to the features of the Tetris version, this version includes: 4-way switch-over valve; liquid storage tank; microprocessor enabling for summer/winter switching and automatic defrosting, with patented Blue Box logic to optimize defrosting time independently on each circuit. HYDRAULIC MODULE OPTIONS TETRIS /ST: Unit with tank e pumps In addition to the features of the Tetris version, this unit can be supplied with an insulated inertial storage tank and circulation pumps. The following configurations are available: ST 1PS: with 1 pump and tank; ST 1P: with 1 pump without tank; ST 2PS: with 2 pumps and tank (from size 10.2 to 24.3); ST 2P: with 2 pumps without tank (from size 10.2 to 24.3); ST 3PS: with 3 pumps and tank (from size 27.4 to 93.12); ST 3P: with 3 pumps without tank (from size 27.4 to 93.12); On the version with 2 circulation pumps (one on standby for the other, both sized for 100% of total flow), switching from one pump to the other is automatic in case of breakdowns or can be set by time. On the version with 3 pumps (each sized for 33% of total flow) all 3 pumps work at the same time; if one pump breaks down, up to 78% of the cooling capacity can still be provided. The following accessories are also provided: expansion tank, check valves (except for versions 1P and 1PS) and gate valve at suction intake (only on versions with tank). TETRIS /DS: Unit with desuperheaters In addition to the features of the Tetris version, this unit includes a recovery condenser on each refrigerant circuit for recovering 20% of the heat of condensation, installed in series with the condensing coil. The condenser is a plate-type condenser. For best performance, this accessory should be used together with a fan speed control. This version is also available in the HP configuration. In this case, the installation must include a cut-off on the recovery water circuit during HP operation, as indicated in the manual. TETRIS /LN: Low-noise unit In addition to having the features of the Tetris version, on this unit the compressor compartment is completely soundproofed with sound-absorbing material and the insertion of sounddeadening material. TETRIS /SLN: Super low-noise unit In addition to having the components of the Tetris/LN version, on this unit the fan speed is reduced by an automatic fan speed control, when allowed by local conditions. ACCESSORY VERSIONS TETRIS /DC: Unit with recovery condenser In addition to the features of the Tetris version, this unit includes a recovery condenser on each refrigerant circuit for recovering 100% of the heat of condensation from the plates for hot water, and a liquid collector. The control automatically starts heat recovery depending on the water temperature, and stops recovery for safety reasons when the pressure is too high. For best performance, this accessory should be used together with a fan speed control. 8 Technical Catalogue Tetris

9 ACCESSORIES REFRIGERANT CIRCUIT ACCESSORY Condensation pressure controlled by fan speed control for working in low outdoor temperatures (standard on SLN version); Dual set point (high/low temperature) with single electronic thermostatic valve at no extra cost. Evaporator sized for working at high temperature. Set points can be changed from the keyboard or by digital input (in this case must be requested at time of order); High and low pressure gauges are available for all models (suction and discharge pressures are shown on the control s display even on standard configurations on models from 20.3 to 93.12); HYDRAULIC CIRCUIT ACCESSORIES Antifreeze heater for evaporator (the /ST version also has antifreeze heaters on the tank and on the pump pipes and volute), and on recovery heat exchangers, if present; Safety valve on water side (/ST version only); Victaulic Y-filter on water side. ELECTRICAL ACCESSORIES RS485 serial interface; Support for Carel, Modbus-Jbus communication protocols; Support for Echelon and Bacnet communication protocols, can be integrated with Johnson and Trend supervision (only available from size 20.3); Potential-free operation contacts; Power factor correction cosφ 0.9 at nominal operating conditions; standard on external panel of units having IP 55 (power supply to be provided by installer directly from the mains); this accessory is designed for use with potential-free operation contacts; Remote user terminal (in addition to standard terminal); Set point adjustable by remote signal (0-1V, 0-10V, 0-4mA, 0-20mA) This accessory is available only from size 20.3); Buffer battery for electronic expansion valve; Outlet water temperature control; Electronic soft-starter. Tetris OTHER ACCESSORIES EC fans. Tetris units can be used with the new direct current EC (Electronically Commutated) axial fans with electronically commutated brushless motors. Rubber or spring-type anti-vibration mounts; Prepainted aluminium condensing coil; Condensing coil treatment with passivated aluminium and polyurethanebased coating. The treatment consists of two layers, the first an aluminium passivating agent acting as a primer, and the second a polyurethane-based surface coating. The product is highly corrosion-resistant and can support almost any environmental conditions, including marine installations, rural environments, industrial areas and urban environments; Coil protection grid with anti-hail metal filter; Shipped in wooden crate; Special pallet/sled for container shipment; Delivered preassembled. The unit is delivered without refrigerant charge and untested; Non-standard RAL paint colours. 9

10 10

11 technical data standard unit Unit size TETRIS - Cooling Nominal cooling capacity (1) kw 110,1 120,8 130,8 143,2 160,0 196,6 229,9 Total power input for cooling (1),(2) kw 38,5 45,3 52,3 55,5 64,0 78,6 84,7 Compressor absorbed power (1) kw 35,2 42,0 49,0 52,2 60,7 73,6 78,1 EER (1) 2,86 2,67 2,50 2,58 2,50 2,50 2,72 ESEER 3,95 3,92 3,68 3,84 3,59 3,94 3,82 TETRIS/HP - Cooling Nominal cooling capacity (1) kw 106,9 117,3 127,0 139,0 155,3 190,9 229,9 Total power input for cooling (1),(2) kw 41,8 48,6 55,6 58,8 67,9 83,5 89,6 Compressor absorbed power (1) kw 38,5 45,3 52,3 55,5 64,6 78,5 83,0 EER (1) 2,56 2,41 2,28 2,36 2,29 2,29 2,57 ESEER 3,53 3,55 3,36 3,52 3,28 3,60 3,61 TETRIS/HP - Heating Nominal heating capacity (3) kw 107,1 118,1 128,0 145,0 161,9 191,9 229,9 Total power input for heating (2),(3) kw 37,3 42,2 46,8 50,4 56,9 69,6 84,8 Compressor absorbed power (1) kw 34,0 38,9 43,5 47,1 53,6 64,7 78,2 COP (3) 2,87 2,80 2,74 2,88 2,85 2,76 2,71 Compressors Type Scroll Quantity / Circuits n /n 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 3 / 1 3 / 1 Capacity steps n Total oil charge kg 13,4 13,4 13,4 13,9 14,4 20,1 21,6 Total refrigerant charge TETRIS kg 11,5 11,6 11,8 15,0 15,2 18,3 23,7 Total refrigerant charge TETRIS/HP kg 26,8 26,9 27,1 32,5 32,7 37,4 50,5 Fans Type Axial Quantity n Air flow m 3 /h Evaporator Type Plates Quantity Water flow TETRIS (7) l/h Water flow TETRIS/HP (7) l/h (8) l/h Pressure drop TETRIS (7) kpa 46,3 51,0 51,8 50,0 50,0 45,9 45,5 Pressure drop TETRIS/HP (7) kpa 43,6 48,1 48,9 47,1 47,1 43,3 45,5 (8) kpa 43,8 48,8 49,6 51,3 51,2 43,7 45,5 Hydraulic module External available pressure (7) kpa 136,0 118,9 99,3 132,7 122,4 138,5 189,9 Tank capacity (7) l Expansion vessel l Sound level Sound power value (standard unit) (4) db(a) Sound pressure value (standard unit) (5) db(a) Sound power value (LN version) (4) db(a) Sound pressure value (LN version) (5) db(a) Sound power value (SLN version) (4) db(a) Sound pressure value (SLN version) (5) db(a) Basic unit size and weights Length mm Width mm Height mm Operating weigh kg (1) Ambient air temperature 35 C; evaporator inlet/outlet water temperature 12-7 C (2) Total power input is sum of compressors and funs power input (3) Ambient air temperature 7 C DB, 6 C WB; conderser inlet/outlet water temperature C (4) Sound power values calculate in compliance with ISO 3744 This datasheet gives the characteristic data of the basic and standard versions of the series; for details refer to the specific documentation. (5) Sound pressure values measured at 10 meters from the unit in free field conditions and directional factor Q=2 (6) In ST 2PS or ST 3PS versions (7) Evaporator inlet/outlet water temperature 12-7 C (8) Evaporator inlet/outlet water temperature C 11

12 technical data standard unit Unit size TETRIS - Cooling Nominal cooling capacity (1) kw 266,5 288,9 307,9 327,5 355,2 399,1 429,1 Total power input for cooling (1),(2) kw 105,3 114,3 123,0 130,9 140,1 157,8 171,2 Compressor absorbed power (1) kw 98,7 107,7 116,4 122,6 131,8 147,9 161,3 EER (1) 2,53 2,53 2,50 2,50 2,54 2,53 2,51 ESEER 4,17 4,12 4,14 4,30 4,40 4,20 4,12 TETRIS/HP - Cooling Nominal cooling capacity (1) kw 258,7 280,4 298,9 317,9 344,9 387,3 416,6 Total power input for cooling (1),(2) kw 111,9 120,9 129,5 139,1 145,3 167,7 181,1 Compressor absorbed power (1) kw 105,3 114,3 122,9 130,8 137,0 157,8 171,2 EER (1) 2,31 2,32 2,31 2,29 2,37 2,31 2,30 ESEER 3,81 3,78 3,82 3,93 4,12 3,84 3,78 TETRIS/HP - Heating Nominal heating capacity (3) kw 255,8 281,2 306,5 319,8 349,4 383,7 421,8 Total power input for heating (2),(3) kw 92,0 98,6 105,8 116,4 121,3 137,9 148,1 Compressor absorbed power (1) kw 85,4 92,0 99,2 108,2 113,1 128,0 138,2 COP (3) 2,78 2,85 2,90 2,75 2,88 2,78 2,85 Compressors Type Scroll Quantity / Circuits n /n 4 / 2 4 / 2 4 / 2 5 / 2 5 / 2 6 / 2 6 / 2 Capacity steps n Total oil charge kg 26,8 27,8 28,8 33,5 34,5 40,2 41,7 Total refrigerant charge TETRIS kg 24,8 28,7 31,7 32,4 35,4 37,4 43,2 Total refrigerant charge TETRIS/HP kg 55,3 61,5 66,7 70,0 72,0 75,6 89,1 Fans Type Axial Quantity n Air flow m 3 /h Evaporator Type Plates Quantity Water flow TETRIS (7) l/h Water flow TETRIS/HP (7) l/h (8) l/h Pressure drop TETRIS (7) kpa 41,9 36,4 41,0 31,3 36,8 43,9 42,1 Pressure drop TETRIS/HP (7) kpa 39,5 34,3 38,6 29,5 34,7 41,4 39,7 (8) kpa 38,6 34,5 40,6 29,9 35,6 40,6 40,7 Hydraulic module External available pressure (7) kpa 153,7 150,3 134,7 243,0 234,0 212,9 206,1 Tank capacity (7) l Expansion vessel l Sound level Sound power value (standard unit) (4) db(a) Sound pressure value (standard unit) (5) db(a) Sound power value (LN version) (4) db(a) Sound pressure value (LN version) (5) db(a) Sound power value (SLN version) (4) db(a) Sound pressure value (SLN version) (5) db(a) Basic unit size and weights Length mm Width mm Height mm Operating weigh kg ((1) Ambient air temperature 35 C; evaporator inlet/outlet water temperature 12-7 C (2) Total power input is sum of compressors and funs power input (3) Ambient air temperature 7 C DB, 6 C WB; conderser inlet/outlet water temperature C (4) Sound power values calculate in compliance with ISO 3744 This datasheet gives the characteristic data of the basic and standard versions of the series; for details refer to the specific documentation. (5) Sound pressure values measured at 10 meters from the unit in free field conditions and directional factor Q=2 (6) In ST 2PS or ST 3PS versions (7) Evaporator inlet/outlet water temperature 12-7 C (8) Evaporator inlet/outlet water temperature C 12

13 technical data standard unit Unit size TETRIS - Cooling Nominal cooling capacity (1) kw 459,5 486,3 533,1 574,5 615,9 660,5 683,6 Total power input for cooling (1),(2) kw 184,1 198,4 210,5 228,2 246,0 262,6 277,3 Compressor absorbed power (1) kw 174,2 186,9 197,3 215,0 232,8 247,7 262,5 EER (1) 2,50 2,45 2,53 2,52 2,50 2,52 2,46 ESEER 4,30 4,20 4,30 4,27 4,28 4,33 4,24 TETRIS/HP - Cooling Nominal cooling capacity (1) kw 450,3 472,1 517,4 557,5 597,9 641,5 663,5 Total power input for cooling (1),(2) kw 194,0 210,0 223,7 241,5 259,1 277,4 292,2 Compressor absorbed power (1) kw 184,1 198,4 210,5 228,3 245,9 262,6 277,4 EER (1) 2,32 2,25 2,31 2,31 2,31 2,31 2,27 ESEER 4,00 3,85 3,93 3,92 3,95 3,98 3,91 TETRIS/HP - Heating Nominal heating capacity (3) kw 459,6 485,8 511,6 562,2 612,9 651,2 689,2 Total power input for heating (2),(3) kw 159,0 172,0 184,1 197,9 211,7 228,7 238,9 Compressor absorbed power (1) kw 149,1 160,4 170,9 184,7 198,5 213,8 224,1 COP (3) 2,89 2,82 2,78 2,84 2,90 2,85 2,88 Compressors Type Scroll Quantity / Circuits n /n 6 / 2 7 / 3 8 / 4 8 / 4 8 / 4 9 / 3 9 / 3 Capacity steps n Total oil charge kg 43,2 48,4 53,6 55,6 57,6 63,3 64,8 Total refrigerant charge TETRIS kg 47,6 0,0 0,0 0,0 0,0 0,0 0,0 Total refrigerant charge TETRIS/HP kg 101,3 0,0 0,0 0,0 0,0 0,0 0,0 Fans Type Axial Quantity n Air flow m 3 /h Evaporator Type Plates Quantity Water flow TETRIS (7) l/h Water flow TETRIS/HP (7) l/h (8) l/h Pressure drop TETRIS (7) kpa 47,1 45,5 41,9 41,9 40,7 45,9 45,5 Pressure drop TETRIS/HP (7) kpa 45,2 42,9 39,5 39,5 38,3 43,3 42,9 (8) kpa 47,1 45,4 38,6 40,1 40,3 44,6 46,3 Hydraulic module External available pressure (7) kpa 188,5 169,0 151,4 129,2 176,0 147,2 155,6 Tank capacity (7) l Expansion vessel l Sound level Sound power value (standard unit) (4) db(a) Sound pressure value (standard unit) (5) db(a) Sound power value (LN version) (4) db(a) Sound pressure value (LN version) (5) db(a) Sound power value (SLN version) (4) db(a) Sound pressure value (SLN version) (5) db(a) Basic unit size and weights Length mm Width mm Height mm Operating weigh kg ((1) Ambient air temperature 35 C; evaporator inlet/outlet water temperature 12-7 C (2) Total power input is sum of compressors and funs power input (3) Ambient air temperature 7 C DB, 6 C WB; conderser inlet/outlet water temperature C (4) Sound power values calculate in compliance with ISO 3744 This datasheet gives the characteristic data of the basic and standard versions of the series; for details refer to the specific documentation. (5) Sound pressure values measured at 10 meters from the unit in free field conditions and directional factor Q=2 (6) In ST 2PS or ST 3PS versions (7) Evaporator inlet/outlet water temperature 12-7 C (8) Evaporator inlet/outlet water temperature C 13

14 technical data standard unit Unit size TETRIS - Cooling Nominal cooling capacity (1) kw 730,4 771,7 798,1 862,8 927,7 Total power input for cooling (1),(2) kw 289,3 307,0 315,6 341,9 368,2 Compressor absorbed power (1) kw 272,8 290,5 295,8 322,1 348,4 EER (1) 2,53 2,51 2,53 2,52 2,52 ESEER 4,37 4,35 4,43 4,42 4,41 TETRIS/HP - Cooling Nominal cooling capacity (1) kw 708,9 749,6 774,7 837,6 900,5 Total power input for cooling (1),(2) kw 305,8 323,5 335,4 361,6 388,0 Compressor absorbed power (1) kw 289,3 307,0 315,6 341,8 368,2 EER (1) 2,32 2,32 2,31 2,32 2,32 ESEER 4,01 4,01 4,04 4,05 4,06 TETRIS/HP - Heating Nominal heating capacity (3) kw 715,4 766,1 767,5 843,3 919,3 Total power input for heating (2),(3) kw 251,1 264,8 275,8 297,0 318,0 Compressor absorbed power (1) kw 234,6 248,3 256,0 277,2 298,2 COP (3) 2,85 2,89 2,78 2,84 2,89 Compressors Type Scroll Quantity / Circuits n /n 10 / 4 10 / 4 12 / 4 12 / 4 12 / 4 Capacity steps n Total oil charge kg 70,0 72,0 80,4 83,4 86,4 Total refrigerant charge TETRIS kg 0,0 0,0 0,0 0,0 0,0 Total refrigerant charge TETRIS/HP kg 0,0 0,0 0,0 0,0 0,0 Fans Type Axial Quantity n Air flow m 3 /h Evaporator Type Plates Quantity Water flow TETRIS (7) l/h Water flow TETRIS/HP (7) l/h (8) l/h Pressure drop TETRIS (7) kpa 47,1 47,1 43,9 43,9 47,1 Pressure drop TETRIS/HP (7) kpa 44,4 44,4 41,4 41,4 44,4 (8) kpa 45,2 46,4 40,6 41,9 46,2 Hydraulic module External available pressure (7) kpa 154,8 182,7 180,4 161,8 138,2 Tank capacity (7) l Expansion vessel l Sound level Sound power value (standard unit) (4) db(a) Sound pressure value (standard unit) (5) db(a) Sound power value (LN version) (4) db(a) Sound pressure value (LN version) (5) db(a) Sound power value (SLN version) (4) db(a) Sound pressure value (SLN version) (5) db(a) Basic unit size and weights Length mm Width mm Height mm Operating weigh kg ((1) Ambient air temperature 35 C; evaporator inlet/outlet water temperature 12-7 C (2) Total power input is sum of compressors and funs power input (3) Ambient air temperature 7 C DB, 6 C WB; conderser inlet/outlet water temperature C (4) Sound power values calculate in compliance with ISO 3744 This datasheet gives the characteristic data of the basic and standard versions of the series; for details refer to the specific documentation. (5) Sound pressure values measured at 10 meters from the unit in free field conditions and directional factor Q=2 (6) In ST 2PS or ST 3PS versions (7) Evaporator inlet/outlet water temperature 12-7 C (8) Evaporator inlet/outlet water temperature C 14

15 electrical data of standard unit Unit size Max. absorbed power (1),(3) kw 55,1 61,5 67,9 73,7 79,5 (57,0) (63,7) (70,1) (75,9) (81,7) Max. absorbed current (2),(3) A 110,6 124,6 138,6 152,6 166,6 (115,6) (129,2) (143,2) (157,2) (171,2) Max. starting current (4) A (280) (324) (338) (398) (412) Fan rated power n x kw 2 x 2,0 2 x 2,0 2 x 2,0 2 x 2,0 2 x 2,0 Fan rated current n x A 2 x 4,3 2 x 4,3 2 x 4,3 2 x 4,3 2 x 4,3 Pump rated power (5) kw 1,9 2,2 2,2 2,2 2,2 Pump rated current (5) A 5,0 4,6 4,6 4,6 4,6 Pump rated power (6) kw Pump rated current (6) A Electric power supply V/ph/Hz 400/3~/50 ±5% Control circuits power supply V/ph/Hz /1~/50 ±5% Unit size Max. absorbed power (1),(3) kw 101,9 119,3 135,9 147,5 159,0 (104,9) (124,8) (141,5) (153,1) (164,6) Max. absorbed current (2),(3) A 207,9 249,9 277,2 305,2 333,2 (214,0) (260,6) (292,1) (320,1) (348,1) Max. starting current (4) A (409) (502) (487) (561) (589) Fan rated power n x kw 3 x 2,0 3 x 2,0 4 x 2,0 4 x 2,0 4 x 2,0 Fan rated current n x A 3 x 4,3 3 x 4,3 4 x 4,3 4 x 4,3 4 x 4,3 Pump rated power (5) kw 3,0 5,5 5,5 5,5 5,5 Pump rated current (5) A 6,1 10,7 10,7 10,7 10,7 Pump rated power (6) kw - - 5,6 5,6 5,6 Pump rated current (6) A ,9 14,9 14,9 Electric power supply V/ph/Hz 400/3~/50 ±5% Control circuits power supply V/ph/Hz /1~/50 ±5% Unit size Max. absorbed power (1),(3) kw 169,9 181,4 203,8 221,2 238,6 (178,9) (190,4) (212,8) (230,4) (247,8) Max. absorbed current (2),(3) A 346,5 374,5 415,8 457,8 499,8 (364,8) (392,8) (434,1) (476,8) (518,8) Max. starting current (4) A (560) (634) (629) (718) (760) Fan rated power n x kw 5 x 2,0 5 x 2,0 6 x 2,0 6 x 2,0 6 x 2,0 Fan rated current n x A 5 x 4,3 5 x 4,3 6 x 4,3 6 x 4,3 6 x 4,3 Pump rated power (5) kw 5,5 5,5 5,5 9,2 9,2 Pump rated current (5) A 10,7 10,7 10,7 19,0 19,0 Pump rated power (6) kw 9,0 9,0 9,0 9,0 9,0 Pump rated current (6) A 18,3 18,3 18,3 18,3 18,3 Electric power supply V/ph/Hz 400/3~/50 ±5% Control circuits power supply V/ph/Hz /1~/50 ±5% (1) Mains power supply to allow unit operation (2) Maximum current before safety cut-outs stop the unit. This value is never exceeded and must be used to size the electrical supply cables and relevant safety devices (refer to electrical wiring diagram supplied with the unit). (3) Values in brackets refer to ST version units (units with storage tank and pumps or units with exclusively pumps). (4) Maximum starting current calculated considering the bigger size compressor starting current plus the maximum absorbed power of the other electrical devices (pumps, fans). (5) Versions: ST 1P, ST 1PS, ST 2P, ST 2PS. Datas are refered to a single pump (6) Versions: ST 3P, ST 3PS. Datas are refered to a single pump 15

16 electrical data of standard unit Unit size Max. absorbed power (1),(3) kw 255,2 271,8 294,9 318,1 340,5 (264,4) (281,0) (304,1) (330,1) (352,5) Max. absorbed current (2),(3) A 527,1 554,4 610,4 666,4 707,7 (546,1) (573,4) (629,4) (690,8) (732,1) Max. starting current (4) A (787) (768) (870) (932) (973) Fan rated power n x kw 7 x 2,0 8 x 2,0 8 x 2,0 8 x 2,0 9 x 2,0 Fan rated current n x A 7 x 4,3 8 x 4,3 8 x 4,3 8 x 4,3 9 x 4,3 Pump rated power (5) kw 9,2 9,2 9,2 9,2 11,0 Pump rated current (5) A 19,0 19,0 19,0 19,0 21,6 Pump rated power (6) kw 9,0 9,0 9,0 12,0 12,0 Pump rated current (6) A 18,3 18,3 18,3 24,4 24,4 Electric power supply V/ph/Hz 400/3~/50 ±5% Alimentación auxiliares V/ph/Hz /1~/50 ±5% Unit size Max. absorbed power (1),(3) kw 357,8 374,4 397,6 407,6 442,4 (369,8) (386,4) (414,1) (424,1) (458,9) Max. absorbed current (2),(3) A 749,7 777,0 833,0 831,6 915,6 (774,1) (801,4) (865,1) (863,7) (947,7) Max. starting current (4) A (1.015) (1.042) (1.106) (1.059) (1.189) Fan rated power n x kw 9 x 2,0 10 x 2,0 10 x 2,0 12 x 2,0 12 x 2,0 Fan rated current n x A 9 x 4,3 10 x 4,3 10 x 4,3 12 x 4,3 12 x 4,3 Pump rated power (5) kw 11,0 11,0 11,0 11,0 15,0 Pump rated current (5) A 21,6 21,6 21,6 21,6 28,6 Pump rated power (6) kw 12,0 12,0 16,5 16,5 16,5 Pump rated current (6) A 24,4 24,4 32,1 32,1 32,1 Electric power supply V/ph/Hz 400/3~/50 ±5% Alimentación auxiliares V/ph/Hz /1~/50 ±5% Unit size Max. absorbed power (1),(3) kw 477,1 (493,6) Max. absorbed current (2),(3) A 999,6 (1.031,7) Max. starting current (4) A (1.273) Fan rated power n x kw 12 x 2,0 Fan rated current n x A 12 x 4,3 Pump rated power (5) kw 15,0 Pump rated current (5) A 28,6 Pump rated power (6) kw 16,5 Pump rated current (6) A 32,1 Electric power supply V/ph/Hz 400/3~/50 ±5% Alimentación auxiliares V/ph/Hz /1~/50 ±5% (1) Mains power supply to allow unit operation (2) Maximum current before safety cut-outs stop the unit. This value is never exceeded and must be used to size the electrical supply cables and relevant safety devices (refer to electrical wiring diagram supplied with the unit). (3) Values in brackets refer to ST version units (units with storage tank and pumps or units with exclusively pumps). (4) Maximum starting current calculated considering the bigger size compressor starting current plus the maximum absorbed power of the other electrical devices (pumps, fans). (5) Versions: ST 1P, ST 1PS, ST 2P, ST 2PS. Datas are refered to a single pump (6) Versions: ST 3P, ST 3PS. Datas are refered to a single pump 16

17 Tetris - Cooling capacity Model AMBIENT AIR TEMPERATURE [ C] To [ C] Pf Pe Pf Pe Pf Pe Pf Pe Pf Pe 5 117,35 27,99 110,76 31,14 103,79 34,67 96,4 38,61 91,75 41, ,85 28,23 114,11 31,39 106,98 34,93 99,43 38,9 94,69 41, ,37 28,47 117,44 31,64 110,1 35,2 102,31 39,18 97,41 41, ,98 28,73 120,86 31,9 113,32 35,47 105,33 39,47 100,3 42, ,61 28,98 124,3 32,17 116,56 35,75 108,36 39,76 103,2 42, ,28 29,25 127,78 32,44 119,84 36,04 111,43 40,06 106,14 42, ,55 33,81 122,05 37,36 114,04 41,32 105,48 45,73 100,07 48, ,33 34,11 125,65 37,68 117,45 41,66 108,7 46,09 103,19 48, ,14 34,41 129, , ,78 46,45 106,09 49, ,06 34,73 132,93 38,33 124,25 42,35 114,99 46,81 109,14 49, ,98 35,05 136,63 38,67 127,72 42,71 118,22 47,19 112,21 50, ,93 35,37 140,36 39,01 131,22 43,07 121,47 47,56 115,31 50, ,31 39,83 132,79 43,79 123,64 48,18 113,85 53,04 107,64 56, ,36 40,2 136,63 44,18 127,27 48,6 117,26 53,5 110,85 56, ,43 40,58 140,44 44,58 130,79 49,02 120,47 53,92 113,93 57, ,6 40,97 144,35 44,99 134,43 49,45 123,83 54,38 117,11 57, ,78 41,36 148,27 45,41 138,09 49,89 127,2 54,83 120,3 58, ,98 41,76 152,22 45,83 141,76 50,33 130,59 55,29 123,52 58, ,38 42,41 145,26 46,58 135,46 51,25 124,93 56,49 118,25 59, ,75 42,83 149,42 47,04 139,38 51,74 128, ,7 60, ,18 43,26 153,55 47,49 143,2 52,21 132,08 57,49 125,01 60, ,7 43,7 157,78 47,96 147,13 52,71 135,7 58,01 128,43 61, ,22 44,15 162,03 48,44 151,08 53,21 139,33 58,54 131,88 62, ,78 44,6 166,29 48,92 155,05 53,73 142,99 59,08 135,33 62, ,53 49,27 162,94 54,08 151,59 59,48 139,42 65,56 131,69 69, ,35 49,81 167,49 54,66 155,86 60,09 143,42 66,21 135,36 70, ,19 50,36 171,99 55, ,7 147,14 66,84 138,98 70, ,13 50,93 176,6 55,85 164,26 61,34 151,04 67,5 142,64 71, ,08 51,51 181,22 56,46 168,53 61,99 154,94 68,18 146,31 72, ,05 52,1 185,85 57,09 172,82 62,65 158,86 68,88 149,99 72, ,46 59,81 199,63 65,75 185,85 72,34 171,11 79,64 161,78 84, ,57 60,38 205,42 66,35 191,33 72,98 176,27 80,33 166,45 85, ,68 60,94 211,14 66,95 196,61 73,61 181,06 80,97 171,22 85, ,94 61, ,57 202,07 74,26 186,1 81,65 175,99 86, ,22 62,12 222,9 68,19 207,56 74,91 191,17 82,33 180,79 87, ,54 62,72 228,83 68,83 213,09 75,58 196,27 83,03 185,63 87, ,11 63,53 232,15 69,79 217,2 76,76 201,25 84,57 191,19 89, ,21 64,11 238,89 70,41 223,57 77,42 207,24 85,26 196,96 90, ,67 64,72 245,69 71,04 229,92 78,08 213,1 85,94 202,48 91, ,83 65,31 252,65 71,69 236,42 78,77 219,13 86,66 208,23 91, ,26 65,93 259,64 72,35 242,96 79,47 225,2 87, , ,75 66,57 266,69 73,03 249,55 80,18 231,32 88,14 219,83 93,35 All values is refered to basic version Pf: cooling capacity [kw] Pe: compressors power imput [kw] To: evaporator water outlet temperature [ C] 17

18 Tetris - Cooling capacity Model AMBIENT AIR TEMPERATURE [ C] To [ C] Pf Pe Pf Pe Pf Pe Pf Pe Pf Pe 5 288,29 80,25 270,76 88,18 251,96 96,99 231,86 106,74 219,15 113, ,91 81,04 278,49 88,99 259,17 97,83 238,5 107,62 225,42 113, ,95 81,79 286,39 89,82 266,52 98,71 245,28 108,53 231,84 114, ,4 82,58 294,32 90,66 273,9 99,59 252,09 109,45 238,29 115, ,9 83,39 302,29 91,51 281,32 100,48 258,94 110,38 244,78 116, ,47 84,21 310,33 92,37 288,81 101,38 265,85 111,32 251,32 117, ,36 87,52 294,12 96,09 273,53 105,64 251,51 116,3 237,57 123, ,37 88,46 302,33 97,05 281,13 106,65 258,45 117,35 244,08 124, ,12 89,38 310,73 98,05 288,92 107,69 265,6 118,44 250,82 125, ,12 90,34 319,14 99,06 296,72 108,76 272,76 119,55 257,57 126, ,17 91,31 327,6 100,09 304,56 109,84 279,95 120,69 264,36 127, ,29 92,3 336,12 101,15 312,47 110,95 287,21 121,84 271,2 128, ,38 94,53 313,78 103,72 291,73 114,01 268,14 125,6 253,17 133, ,08 95,64 322,41 104,84 299,73 115,18 275,44 126,81 260,02 134, ,07 96,68 331,24 105,99 307,88 116,4 282,88 128,08 267,01 135, ,53 97,79 340,05 107,17 316,03 117,64 290,33 129,38 274,01 137, ,02 98,92 348,9 108,37 324,21 118,91 297,8 130,7 281,03 138, ,57 100,08 357,8 109,61 332,44 120,2 305,32 132,06 288,08 139, ,15 99,69 332,11 109,59 309,51 120,57 285,13 132,71 269,83 140, ,52 100,61 341,77 110,56 318,34 121,57 293,47 133,78 277,73 141, ,7 101,52 351,39 111,52 327,48 122,61 301,92 134,87 285,76 142, ,18 102,46 361,24 112,52 336,67 123,66 310,42 135,96 293,82 143, ,72 103,42 371,16 113,53 345,92 124,72 318,98 137,08 301,95 145, ,4 104,39 381,18 114,57 355,28 125,81 327,64 138,21 310,18 146, ,19 107,15 361,56 117,65 336,26 129,34 309,22 142,38 291,98 150, ,25 108,27 371,85 118,83 345,62 130,56 317,76 143,64 300,12 152, ,06 109,39 382,02 120,01 355,22 131,82 326,59 144,96 308,44 153, ,16 110,54 392,39 121,24 364,85 133,11 335,43 146,3 316,79 154, ,31 111,71 402,82 122,48 374,53 134,41 344,32 147,67 325,18 156, ,56 112,91 413,34 123,75 384,3 135,75 353,29 149,06 333,64 157, ,6 120,23 405,37 132,13 377,24 145,32 347,18 159,94 328,16 169, ,42 121,42 417,31 133,37 388,04 146,59 357,13 161,27 337,56 170, ,53 122,54 428,78 134,58 399,06 147,9 367,29 162,63 347,18 172, ,19 123,73 440,65 135,83 410,11 149,22 377, ,84 173, ,92 124,93 452,59 137,1 421,23 150,55 387,74 165,39 366,56 175, ,75 126,15 464,63 138,39 432,44 151,9 398,09 166,81 376,36 176, ,2 131,08 436,7 143,92 406,18 158,25 373,55 174,25 352,85 184, ,47 132,47 449,22 145,4 417,52 159,76 383,93 175,82 362,64 186, ,59 133,85 461,41 146,85 429,11 161,32 394,56 177,45 372,67 188, ,97 135,27 473,91 148,36 440,71 162,91 405,21 179,11 382,71 189, ,41 136,72 486,48 149,9 452,36 164,53 415,91 180,8 392,8 191, ,95 138,2 499,14 151,47 464,11 166,18 426,68 182,53 402,97 193,24 All values is refered to basic version Pf: cooling capacity [kw] Pe: compressors power imput [kw] To: evaporator water outlet temperature [ C] 18

19 Tetris - Cooling capacity Model AMBIENT AIR TEMPERATURE [ C] To [ C] Pf Pe Pf Pe Pf Pe Pf Pe Pf Pe 5 498,82 141,43 468,16 155,19 435,34 170,62 400,21 187,99 377,87 199, ,05 143,05 481,66 156,94 447,3 172,37 411,15 189,81 388,2 201, ,69 144,63 494,23 158,58 459,48 174,18 422,29 191,7 398,67 203, ,83 146,28 507,4 160,34 471,67 176,03 433,42 193,63 409,14 205, ,97 520,62 162,13 483,89 177,92 444,58 195,6 419,63 207, ,26 149,69 533,91 163,96 496,18 179,85 455,8 197,63 430,16 209, ,94 151,72 494,41 166,78 460,61 183,61 424,34 202,42 401,32 214, ,83 153, ,31 473,27 185, ,1 412,34 216, ,26 154,66 522,01 169,9 486,33 186,89 448,06 205,85 423,76 218, ,34 156,2 536,19 171,53 499,56 188,61 460,32 207,67 435,45 220, ,72 157,78 550,71 173,23 513,09 190,4 472,61 209,5 447,03 222, ,12 159,39 565,08 174,92 526,45 192,18 485,05 211,39 458,79 223, ,64 160,43 541,56 176,3 503,96 193,89 463,77 213,39 438,35 226, ,88 162,02 557,04 177,91 518,38 195,59 477,04 215,15 450,87 227, ,95 163,52 572,84 179,57 533,09 197,33 490,61 216,97 463,72 229, ,86 165,1 588,69 181,24 547,85 199,09 504,22 218,81 476,62 231, ,86 166,71 604,64 182,94 562,7 200,87 517,92 220,67 489,6 233, ,34 620,72 184,66 577,68 202,68 531,75 222,56 502,7 235, ,78 174,69 584,63 191,8 543,78 210,88 500,08 232,21 472,4 246, ,1 176,59 601,01 193,73 558,99 212,9 514,02 234,31 485,51 248, ,13 178,38 617,73 195,71 574,49 214,99 528,25 236,49 498,93 250, ,04 180,28 634,47 197,72 590,02 217,11 542,5 238,7 512,38 252, ,03 182,21 651,29 199,77 605,62 219,27 556,82 240,95 525,88 255, ,15 184,19 668,24 201,87 621,34 221,47 571,25 243,25 539,49 257, ,95 189,06 627,73 207,42 583,63 228,01 536,43 251,19 506,49 266, ,36 191,27 645,01 209,67 599,64 230,36 551,03 253,62 520,18 268, ,35 193,35 662,67 211,97 615,93 232,79 565,93 256,16 534,18 271, ,27 195,58 680,3 214,34 632,24 235,27 580,82 258,75 548,19 274, ,26 197,84 697,99 216,74 648,6 237,81 595,76 261,4 562,23 276, ,36 200,16 715,81 219,2 665,07 240,4 610,81 264,12 576,33 279, ,61 201,09 672,29 220,86 625,81 242,98 575,99 267,79 544,18 284, ,75 203,21 691,32 223,13 642,93 245,29 591,72 270,2 559,2 286, ,44 205,3 709,64 225,33 660,53 247,7 607,89 272,72 574,48 289, ,82 207,49 728,73 227,66 678,29 250,16 624,27 275, , ,52 209,74 748,2 230,07 696,12 252,66 640,59 277,92 605,33 294, ,16 212,01 767,39 232,48 714,14 255,23 657,09 280,62 620,88 297, ,18 213,01 696,23 233,89 648,09 257,36 596,45 283,81 563,59 301, ,81 215,32 715,72 236,36 665,61 259,87 612,52 286,42 578, ,97 217,6 734,51 238,78 683,61 262,49 629,03 289,16 594,34 306, ,87 220,01 754,05 241,33 701,77 265,19 645,72 291,99 610,14 309, ,05 222,48 773,94 243,97 720,2 267,97 662,42 294,87 625,81 312, , ,68 246,64 738,47 270,79 679,27 297,85 641,64 315,72 All values is refered to basic version Pf: cooling capacity [kw] Pe: compressors power imput [kw] To: evaporator water outlet temperature [ C] 19

20 Tetris - Cooling capacity Model AMBIENT AIR TEMPERATURE [ C] To [ C] Pf Pe Pf Pe Pf Pe Pf Pe Pf Pe 5 801,75 221,01 749,18 242,73 692,94 267,02 632,75 294,21 594,48 312, ,26 223,65 769,77 245,49 711,52 269,84 649,56 297,15 610,12 315, ,63 226,19 789,92 248,22 730,4 272,76 666,67 300,19 626,09 318, ,77 228,88 810,47 251,05 749,27 275,73 683,75 303,28 642,04 321, ,98 231,6 831,05 253,94 768,17 278,76 700,86 306,44 657,98 324, ,29 234,38 851,73 256,88 787,15 281,85 718,04 309,67 673,96 328, ,86 235,91 786,31 258,85 731,14 284,57 672,09 313,52 634,58 332, ,93 238,64 808,58 261,72 751,21 287,49 690,43 316,56 651,85 335, ,69 241,26 830,09 264,51 771,66 290,52 709,12 319,71 669,41 338, ,42 244,02 852,2 267,45 792,11 293,61 727,8 322,94 686,98 342, ,22 246,84 874,38 270,45 812,62 296,76 746,53 326,24 704,58 345, ,16 249,72 896,7 273,51 833,25 299,99 765,38 329,62 722,27 349, ,19 240,49 810,73 264,29 754,49 290,68 694,35 319,91 656,31 338, ,84 242,86 834,62 266,78 776,08 293,22 714,25 322,57 675,11 341, ,06 245,11 857,56 269,18 798,12 295,83 734,58 325,29 694,36 344, ,37 247,48 881,31 271,69 820,23 298,46 754,97 328,04 713,67 347, ,83 249,88 905,18 274,23 842,46 301,13 775,48 330,82 733,11 350, ,49 252,33 929,26 276,81 864,89 303,84 796,19 333,65 752,72 353, ,02 261,69 877,85 287,35 816,6 315,97 751,08 347,96 709,51 369, ,21 264,49 903,42 290,34 839,47 318,99 772,07 351,11 729,34 372, ,09 267,19 927,57 293,18 862,79 322,11 793,47 354,36 749,53 375, ,01 270,03 952,74 296,2 886,14 325,27 814,91 357,66 769,75 378, ,04 272,92 978,01 299,26 909,58 328,49 836,43 361,03 790,05 382, ,27 275, ,47 302,38 933,2 331,78 858,1 364,47 810,49 385, ,11 282,89 945,21 310,42 878,95 341,28 808,01 376,02 762,91 399, ,84 286,13 972,47 313,9 903,09 344,78 830,11 379,66 783,77 402, ,39 289,29 997,84 317,19 927,69 348,4 852,59 383,44 804,91 406, ,92 292,6 1024,44 320,71 952,29 352,1 875,07 387,3 826,04 410, ,55 295, ,12 324,29 976,96 355,87 897,6 391,25 847,22 414, ,34 299, ,96 327, ,77 359,73 920,25 395,31 868,49 418,75 All values is refered to basic version Pf: cooling capacity [kw] Pe: compressors power imput [kw] To: evaporator water outlet temperature [ C] 20

21 Tetris /HP - Cooling capacity Model AMBIENT AIR TEMPERATURE [ C] To [ C] Pf Pe Pf Pe Pf Pe Pf Pe Pf Pe 5 113,94 28,02 107,54 31,17 100,77 34,7 93,6 38,65 89,08 41, ,33 28,26 110,79 31,42 103,87 34,97 96,54 38,94 91,93 41, ,75 28,5 114,02 31,67 106,9 35,23 99,34 39,22 94,58 41, ,26 28,76 117,35 31,94 110,02 35,51 102,26 39,51 97,38 42, ,79 29,01 120,69 32,2 113,17 35,79 105,21 39,8 100,2 42, ,35 29,28 124,06 32,48 116,35 36,08 108,19 40,1 103,05 42, ,81 33,79 118,52 37,34 110,74 41,3 102,43 45,7 97,18 48, ,47 34,09 122,02 37,66 114,05 41,64 105,56 46,07 100,21 48, ,18 34,39 125,51 37,98 117,31 41,98 108,55 46,42 103,02 49, ,98 34,71 129,08 38,31 120,66 42,33 111,67 46,79 105,99 49, ,79 35,03 132,68 38,65 124,03 42,68 114,8 47,16 108,97 50, ,63 35,35 136,3 38,99 127,42 43,04 117,96 47,53 111,98 50, ,26 39,83 128,98 43,79 120,1 48,18 110,58 53,04 104,56 56, ,19 40,2 132,71 44,18 123,62 48,6 113,9 53,5 107,67 56, ,15 40,58 136,42 44,58 127,04 49,02 117,01 53,92 110,66 57, ,19 40,97 140,21 44,99 130,58 49,45 120,27 54,38 113,75 57, ,25 41,36 144,02 45,41 134,13 49,89 123,55 54,83 116,85 58, ,34 41,76 147,85 45,83 137,7 50,33 126,85 55,29 119,98 58, ,88 42,41 141,03 46,58 131,52 51,25 121,29 56,49 114,8 59, ,12 42,83 145,07 47,04 135,32 51,74 124, ,15 60, ,43 43,26 149,08 47,49 139,03 52,21 128,24 57,49 121,37 60, ,81 43,7 153,19 47,96 142,85 52,71 131,75 58,01 124,69 61, ,2 44,15 157,3 48,44 146,68 53,21 135,28 58,54 128,03 62, ,63 44,6 161,45 48,92 150,53 53,73 138,82 59,08 131,39 62, ,43 49,79 158,15 54,65 147,13 60,11 135,32 66,25 127,81 70, ,1 50,33 162,56 55,23 151,28 60,73 139,2 66,91 131,37 70, ,8 50,89 166,93 55,82 155,29 61,34 142,81 67,54 134,89 71, ,6 51,47 171,41 56,44 159,43 61,98 146,6 68,21 138,44 72, ,4 52,06 175,88 57,06 163,57 62,64 150,38 68, , ,22 52,65 180,38 57,69 167,73 63,31 154,18 69,6 145,57 73, ,31 59,78 193,85 65,72 180,47 72,3 166,16 79,6 157,09 84, ,24 60,35 199,47 66,32 185,79 72,95 171,16 80,29 161,63 85, ,18 60,91 205,02 66,92 190,92 73,57 175,82 80,93 166,26 85, ,25 61,5 210,72 67,54 196,22 74,22 180,71 81,61 170,9 86, ,35 62,09 216,44 68,16 201,55 74,88 185,63 82,29 175,56 87, ,49 62,69 222,2 68,79 206,92 75,54 190,59 82,99 180,26 87, ,02 63,53 225,46 69,79 210,94 76,76 195,45 84,57 185,68 89, ,91 64, ,41 217,12 77,42 201,27 85,26 191,28 90, ,15 64,72 238,61 71,04 223,29 78,08 206,95 85,94 196,65 91, ,11 65,31 245,37 71,69 229,61 78,77 212,82 86,66 202,23 91, ,33 65,93 252,15 72,35 235,96 79,47 218,71 87,39 207,83 92, ,6 66, ,03 242,36 80,18 224,65 88,14 213,49 93,35 All values is refered to basic version Pf: cooling capacity [kw] Pe: compressors power imput [kw] To: evaporator water outlet temperature [ C] 21

22 Tetris /HP - Cooling capacity Model AMBIENT AIR TEMPERATURE [ C] To [ C] Pf Pe Pf Pe Pf Pe Pf Pe Pf Pe 5 279,82 80,22 262,8 88,15 244,56 96,95 225,05 106,69 212,71 113, ,19 81,01 270,31 88,96 251,55 97,8 231,49 107,58 218,79 113, ,99 81,76 277,98 89,78 258,69 98,67 238,07 108,49 225,03 114, ,19 82,55 285,67 90,62 265,85 99,55 244,68 109,4 231,28 115, ,44 83,35 293,41 91,47 273,06 100,44 251,33 110,33 237,58 116, ,76 84,17 301,21 92,33 280,33 101,34 258,04 111,28 243,94 117, ,12 87,55 285,45 96,12 265,46 105,67 244,09 116,34 230,56 123, ,87 88,49 293,41 97,08 272,84 106,68 250,83 117,39 236,88 124, ,36 89,41 301,57 98,08 280,39 107,73 257,76 118,48 243,42 125, ,09 90,36 309,73 99,09 287,97 108,79 264,71 119,59 249,97 126, ,87 91,34 317,94 100,12 295,58 109,88 271,69 120,72 256,56 127, ,72 92,33 326,21 101,18 303,25 110,98 278,74 121,88 263,2 129, ,66 94,48 304,65 103,66 283,25 113,95 260,34 125,53 245,81 133, ,08 95,59 313,04 104,78 291,02 115,12 267,43 126,75 252,46 134, ,81 96,63 321,61 105,93 298,92 116,34 274,66 128,01 259,25 135, ,99 97,74 330,16 107,11 306,84 117,58 281,88 129,31 266,05 137, ,2 98,87 338,75 108,32 314,78 118,84 289,14 130,63 272,86 138, ,47 100,03 347,4 109,55 322,77 120,14 296,44 131,99 279,71 139, ,8 99,68 322,37 109,58 300,43 120,55 276,77 132,7 261,92 140, ,86 100,6 331,75 110,55 309,01 121,55 284,87 133,77 269,59 141, ,74 101,51 341,09 111,51 317,88 122,59 293,07 134,85 277,38 142, ,92 102,45 350,65 112,51 326,8 123,64 301,32 135,95 285,21 143, ,15 103,41 360,28 113,52 335,78 124,71 309,63 137,06 293,1 145, ,52 104, ,55 344,86 125,79 318,04 138,2 301,08 146, ,66 351,06 114,92 326,5 126,34 300,24 139,08 283,5 147, ,74 105,76 361,05 116,07 335,58 127,53 308,53 140,31 291,4 148, ,24 106,85 370,92 117,23 344,91 128,76 317,1 141,59 299, ,01 107,97 380,99 118,42 354,26 130,01 325,69 142,9 307,59 151, ,84 109,12 391,12 119,63 363,66 131,29 334,32 144,24 315,74 152, ,76 110,29 401,33 120,87 373,13 132,59 343,03 145,6 323,95 154, ,91 120,25 393,46 132,14 366,16 145,34 336,97 159,96 318,51 169, ,36 121,43 405,05 133,39 376,64 146,61 346,63 161,28 327,64 170, ,11 122,55 416,18 134,59 387,33 147,91 356,5 162,64 336,98 172, ,4 123,74 427,71 135,84 398,06 149,23 366,39 164,02 346,35 173, ,76 124,94 439,29 137,11 408,85 150,56 376,35 165,41 355,78 175, ,21 126,17 450,98 138,41 419,74 151,92 386,4 166,82 365,3 176, ,67 131, ,92 394,37 158,25 362,68 174,25 342,59 184, ,55 132,47 436,16 145,4 405,38 159,76 372,77 175,82 352,09 186, ,29 133,85 447,99 146,85 416,63 161,32 383,09 177,45 361,83 188, ,28 135,27 460,13 148,36 427,89 162,91 393,43 179,11 371,58 189, ,33 136,72 472,33 149,9 439,21 164,53 403,81 180,8 381,38 191, ,48 138,2 484,62 151,47 450,61 166,18 414,28 182,53 391,25 193,24 All values is refered to basic version Pf: cooling capacity [kw] Pe: compressors power imput [kw] To: evaporator water outlet temperature [ C] 22

23 Tetris /HP - Cooling capacity Model AMBIENT AIR TEMPERATURE [ C] To [ C] Pf Pe Pf Pe Pf Pe Pf Pe Pf Pe 5 488,8 141,43 458,76 155,19 426,6 170,62 392,17 187,99 370,28 199, ,75 143,05 471,99 156,94 438,32 172,37 402,9 189,81 380,41 201, ,12 144,63 484,31 158,58 450,26 174,18 413,81 191,7 390,67 203, ,97 146,28 497,22 160,34 462,2 176,03 424,72 193,63 400,92 205, ,86 147,97 510,16 162,13 474,17 177,92 435,65 195,6 411,2 207, ,84 149,69 523,19 163,96 486,21 179,85 446,65 197,63 421,52 209, ,53 151,72 479,92 166,78 447,11 183,61 411,91 202,42 389,56 214, ,98 153,2 493,11 168,31 459,4 185,21 423,23 204,1 400,26 216, ,99 154,66 506,72 169,9 472,08 186,89 434,93 205,85 411,35 218, ,63 156,2 520,48 171,53 484,93 188,61 446,84 207,67 422,69 220, ,55 157,78 534,58 173,23 498,06 190,4 458,76 209,5 433,93 222, ,51 159,39 548,52 174,92 511,02 192,18 470,84 211,39 445,35 223, ,64 160,43 525,6 176,3 489,11 193,89 450,1 213,39 425,43 226, ,38 162,02 540,62 177,91 503,1 195,59 462,98 215,15 437,58 227, ,97 163,52 555,96 179,57 517,38 197,33 476,15 216,97 450,05 229, ,38 165,1 571,34 181,24 531,7 199,09 489,36 218,81 462,57 231, ,88 166,71 586,81 182,94 546,11 200,87 502,66 220,67 475,17 233, ,52 168,34 602,42 184,66 560,65 202,68 516,08 222,56 487,88 235, ,39 174,79 567,37 191,91 527,72 211,01 485,32 232,35 458,46 246, ,17 176,69 583,26 193,84 542,49 213,03 498,84 234,45 471,17 248, ,7 178,48 599,49 195,82 557,53 215,12 512,65 236,63 484,2 250, ,08 180,39 615,74 197,84 572,6 217,24 526,48 238,84 497, ,54 182,32 632,06 199,89 587,74 219,4 540,38 241,1 510,36 255, ,13 184,3 648,51 201, ,6 554,39 243,4 523,56 257, ,31 188,96 609,3 207,32 566,49 227,9 520,68 251,06 491,62 266, ,15 191,18 626,08 209,56 582,03 230,24 534,86 253,49 504,91 268, ,61 193,26 643,21 211,87 597,85 232,68 549,31 256,03 518,5 271, ,98 195,48 660,33 214,23 613,68 235,15 563,77 258,62 532,09 274, ,41 197,74 677,5 216,63 629,56 237,69 578,27 261,27 545,72 276, ,94 200,06 694,79 219,09 645,54 240,28 592,88 263,98 559,41 279, ,99 201,09 652,92 220,86 607,78 242,98 559,39 267,79 528,5 284, ,55 203,21 671,4 223,13 624,41 245,29 574,67 270,2 543,09 286, ,68 205,3 689,2 225,33 641,5 247,7 590,37 272,72 557,93 289, ,47 207,49 707,73 227,66 658,75 250,16 606,28 275, , ,57 209,74 726,64 230,07 676,07 252,66 622,13 277,92 587,89 294, ,62 212,01 745,28 232,48 693,57 255,23 638,16 280,62 602,99 297, ,38 213,05 675,76 233,94 629,03 257,41 578,91 283,86 547,01 301, ,4 215,36 694,67 236,41 646,04 259,92 594,51 286,48 561,75 304, ,98 217,65 712,91 238,82 663,51 262,54 610,53 289,22 576,86 306, ,26 220,05 731,88 241,38 681,13 265,24 626,73 292,05 592,19 309, ,82 222,53 751,18 244,02 699,02 268,03 642,93 294,93 607,4 312, ,42 225,04 770,34 246,69 716,75 270,84 659,29 297,91 622,77 315,78 All values is refered to basic version Pf: cooling capacity [kw] Pe: compressors power imput [kw] To: evaporator water outlet temperature [ C] 23

OMEGA V ECHOS Water/water cooled chillers and heat pumps kw

OMEGA V ECHOS Water/water cooled chillers and heat pumps kw Water/water cooled chillers and heat pumps 172 1527 kw General information Water-cooled water chillers with hermetic screw compressors and tube bundle heat exchangers. Designed for installation indoors.

More information

ZETA ECHOS. Chillers and heat pumps Air/water kw. General Air/Water chillers and heat pumps with axial fans and hermetic scroll compressors.

ZETA ECHOS. Chillers and heat pumps Air/water kw. General Air/Water chillers and heat pumps with axial fans and hermetic scroll compressors. Chillers and heat pumps Air/water 41 125 kw General Air/Water chillers and heat pumps with axial fans and hermetic scroll compressors. Versions A: Energy efficient class A HP. Reversible heating LE: Without

More information

AZURA. Air/water multifunctional chiller&heat pump, kw

AZURA. Air/water multifunctional chiller&heat pump, kw AZURA STM Air/water multifunctional chiller&heat pump, 31-211 kw General Air/water unit with indipendent production of chilled water and hot water equipped with axial fans and hermetic scroll compressors.

More information

TEAL FCTM. Chiller with integrated Free Cooling system chillers and heat pumps, kw

TEAL FCTM. Chiller with integrated Free Cooling system chillers and heat pumps, kw TM Chiller with integrated Free Cooling system chillers and heat pumps, 100-530 kw General The TEAL FC range, with scroll compressors and free cooling system, uses the ecofriendly R410A refrigerant and

More information

TEAL FC. Chiller with integrated Free Cooling system kw

TEAL FC. Chiller with integrated Free Cooling system kw TEAL FC Chiller with integrated Free Cooling system 100 530 kw General The TEAL FC range, with scroll compressors and free cooling system, uses the ecofriendly R410A refrigerant. Substantial energy saving,

More information

OMICRON V EVO. Multifunctional unit

OMICRON V EVO. Multifunctional unit Multifunctional unit 231 773 General Air/water unit with indipendent production of chilled water and hot water equipped with axial fans and semihermetic screw compressors. Production of hot water up to

More information

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS Air/water chillers and heat pumps LSE Outdoor packaged unit LSE 60-00 kw Multi-scroll solutions for reliability and high efficiency at partial loads Scroll compressor PLUS R-0A R-0A refrigerant Cooling

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75. Chiller AQL/ to 75 Air Cooled Water Chillers Only and Heat Pump Engineering Data Manual.0 to 75.8 kw 39.9 to 77.2 kw Outstanding Strength Points R410A Refrigerant. New simpler refrigerant circuit layout.

More information

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw TWA 212-1102 S/K/P Incorporating R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw The complete solution to all your cooling needs TWA 212-1102 S/K/P Index

More information

CATÁLOGO TÉCNICO COMERCIAL

CATÁLOGO TÉCNICO COMERCIAL CATÁLOGO TÉCNICO COMERCIAL ENFRIADORAS DE AGUA CONDENSADAS POR AIRE Series LCAEX De 350 a 1600 Kw. Compresor de tornillo R-134A Index Identification code Identification code and index... pag. 2 General

More information

ENR Incorporating

ENR Incorporating ENR 002-480 Incorporating R410A Refrigerant Air cooled water chillers with scroll compressors and axial fans, 2.2-480kW ENR 002-100 models inc. self-cleaning coaxial evaporators ENR 130-480 models inc.

More information

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features

More information

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version)

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version) R u Air Cooled Water Chillers VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version) Models 524 to 1204 137 to 308 kw 150 to 336 kw Engineering Data Manual EDM VL410-W.2GB Date :

More information

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual. Chiller SWS/SWR 1602 to 4802 Water Cooled Chillers Only and Condenserless Versions Engineering Data Manual 272 to 1118 kw Specifications General The SWS water cooled screw chillers are equipped with high

More information

Reversible air-to-water scroll heat pumps

Reversible air-to-water scroll heat pumps Reversible air-to-water scroll heat pumps Model CXAO 120 to 290 Cooling capacity: 420-1030 kw Heating capacity: 475-1175 kw CG-PRC027A-GB Table of Contents Model number description...4 Technical specifications...5

More information

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07. Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water

More information

Epsilon Echos DK kw

Epsilon Echos DK kw silon Echos DK 5 38 kw EPSILON ECHOS DK is the range of chillers and ductable air-water heat pumps. In its standard equipment, the unit is equipped with high pressure axial fans (up to a useful 100Pa),

More information

WQL/WQH/WQRC 524 to 1204

WQL/WQH/WQRC 524 to 1204 Chiller / Close control / Water terminals WQL/WQH/WQRC 524 to 1204 Water Cooled Water Chillers Cooling Only, Heat Pump and Condenserless Versions Engineering Data Manual 155 to 30 kw 170 to 370 kw Features

More information

AQWL/AQWH/AQWR 1404 to 2406

AQWL/AQWH/AQWR 1404 to 2406 Chiller AQWL/AQWH/AQWR 1404 to 2406 Air Cooled Water Chillers Only, Heat Pump and Total Heat Recovery Engineering Data Manual 380 to 634 kw 418 to 702 kw Features & Strength Points A more "slim and light"

More information

Chiller. AQSL 2612 to Air Cooled Chillers With or without total heat recovery Engineering Data Manual. 602 to 908 kw

Chiller. AQSL 2612 to Air Cooled Chillers With or without total heat recovery Engineering Data Manual. 602 to 908 kw Chiller AQSL 2612 to 4212 Air Cooled Chillers With or without total heat recovery Engineering Data Manual 602 to 908 kw Features & Strength Points Sturdy structure, vibration tests and FEM structural analysis.

More information

Flex Series. Modular Air-cooled Chillers and Heat Pumps Cooling Capacity kw Heating Capacity kw

Flex Series. Modular Air-cooled Chillers and Heat Pumps Cooling Capacity kw Heating Capacity kw Flex Series Modular Air-cooled Chillers and Heat Pumps Cooling Capacity 38-329 kw Heating Capacity 47-354 kw 1 Trane Flex Series Modular air/water chillers and heat pumps units with axial fans and scroll

More information

UMXCA/UMXCBA ECVA/ECVBA

UMXCA/UMXCBA ECVA/ECVBA OUTDOOR UNITS Models: 801.1 1001.1 1201.1 1501.1 1602.2 2002.2 2402.2 3002.2 3502.2 4002.2 4502.2 Cooling Capacities: from 25,9 kw to 134,7 kw Heating Capacities: from 27,3 kw to 142,4 kw INDOOR UNITS

More information

AQVSL/AQVSH STAR 85 to 140

AQVSL/AQVSH STAR 85 to 140 Chiller QVSL/ STR 85 to 140 ir Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual 82 to 157 kw 83 to 168 kw Outstanding Strength Points Units with R410 refrigerant (it will be the

More information

Air-Cooled Liquid Chiller with integrated hydraulic module

Air-Cooled Liquid Chiller with integrated hydraulic module Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800

More information

AQVL (Cooling Only Version) AQVH (Heat Pump Version)

AQVL (Cooling Only Version) AQVH (Heat Pump Version) R u Air Cooled Water Chillers (Cooling Only Version) (Heat ump Version) Models 85 to 140 84 to 137 kw 92 to 146 kw Engineering Data Manual EDM AQV-W.1GB Date : November 2009 Supersedes : None High erformance

More information

Y-Flow TCHEY-THHEY

Y-Flow TCHEY-THHEY Y-Flow TCHEY-THHEY 245-4450 Cooling capacity: 41.2 448.8 kw - Heating capacity: 50.23 515.49 kw Applications with well water, water mains or geothermal probes Integrated MASTER/SLAVE control HT65 version

More information

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW Compresseur scroll Refrigerant R410A SYSAQUAC Air Cooled Condensing Units Models 25 to 125 32.0 to 136.0kW SYSAQUA Condensation 1 Key Points R410A refrigerant, Units are optimized for partial load operation,

More information

ZETA REV series kw. General Customisable, high efficiency chiller and air/water heat pump, with hermetic scroll compressors.

ZETA REV series kw. General Customisable, high efficiency chiller and air/water heat pump, with hermetic scroll compressors. series 40 240 kw General Customisable, high efficiency chiller and air/water heat pump, with hermetic scroll compressors. Configurations HE: high efficiency HP: Reversible heat pump SLN: Super low noise

More information

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment Screw compressors CIAT shell and tubes direct expansion evaporator (High Power System) equipment Cooling capacity: 370 to 1 170 kw Heating capacity: 500 to 1 400 kw Heating Cooling Heat recovery Use The

More information

LHA LHA A ++ High efficiency air to water heat pumps EVI EVI EVI DC. Versions

LHA LHA A ++ High efficiency air to water heat pumps EVI EVI EVI DC. Versions LH High efficiency air to water heat pumps ++ Inverter LH -20 C Inverter +43 C Inverter 20 EVI +60 C Inverter DC INVERTER +58 C EVI +65 C COP 4,1 EVI DC INVERTER EVI DC INVERTER DC COP 4,1 INVERTER COP

More information

CXAM. Options. Accessories

CXAM. Options. Accessories CXAM Reversible air-to-water scroll heat pump Customer benefits Life cycle effectiveness Efficiency and sound level without compromise All year round operation Extreme reliability and durability Wide application

More information

VHA. Air cooled chiller with

VHA. Air cooled chiller with TECHNICAL Data Sheet Air cooled chiller with SCROLL OR RECIPROCATING compressors and axial fans for outdoor installation V Range 19-1196 kw Range Air cooled chiller with scroll or reciprocating compressors

More information

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM 1 Lmf Clima 216 FERRARO GROUP HPR Heat recovery units HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM from 7 to 23. m³/h Supporting structure in extruded aluminium profiles and curtain

More information

CGAM. Air-cooled scroll chiller. Accessories. Customer benefits. Tracer CH530 Control. Main features. Energy saving options.

CGAM. Air-cooled scroll chiller. Accessories. Customer benefits. Tracer CH530 Control. Main features. Energy saving options. CGAM Air-cooled scroll chiller Customer benefits Life cycle effectiveness Efficiency and sound level without compromise All year round operation Extreme reliability and durability Wide application flexibility

More information

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

HYDROCIAT LW R134a. Water cooled chillers USE RANGE Screw compressors CIAT direct expansion shell and tubes evaporator equipment (High Power System) Cooling or heating Heat recovery ENVIRONMENTALLY HFC R134a PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

Conditioning your ambient, maximising your comfort.

Conditioning your ambient, maximising your comfort. High efficiency water cooled chillers, heat pumps and evaporating units with screw compressors and R134a refrigerant gas. Cooling capacity 380 1549 kw Heating capacity 427 1740 kw Cooling capacity condenserless

More information

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 330 to 500 kw Heating capacity: 340 to 500 kw Cooling

More information

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw Chiller VLC 524 to 1204 Air Cooled Condensing Units Engineering Data Manual 154 to 347 kw Outstanding Strength Points Units with R410A refrigerant (it will be the real replacement of R22). As near azeotropic

More information

LDA LDA. Air cooled water chillers with axial fans VERSIONS R410A

LDA LDA. Air cooled water chillers with axial fans VERSIONS R410A LD ir cooled water chillers with axial fans R410 222 LD LD water chillers are efficient, low-noise products designed for medium to large applications. They are suitable for generating chilled water at

More information

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105 TECHNICAL CATALOGUE WPHA Cooling only WPHBA Heat pump Models 091, 121, 141, 171, 201, 251, 351, 401, 501, 701, 751, 1001, 1201 Cooling capacities from 2,4 kw to 41 kw Heating capacities from 2,8 kw to

More information

NECS-WQ. Climaveneta Technical Bulletin NECS_WQ_0152_1604_201006_GB. INTEGRA unit for 4-pipe systems, water source ,6-522 kw

NECS-WQ. Climaveneta Technical Bulletin NECS_WQ_0152_1604_201006_GB. INTEGRA unit for 4-pipe systems, water source ,6-522 kw Climaveneta Technical Bulletin NECS_WQ_0152_1604_201006_GB r HFC R-410A 0152-1604 48,6-522 kw INTEGRA unit for 4-pipe systems, water source (The photo of the unit is indicative and may change depending

More information

next dx next dx rcgroupairconditioning NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans.

next dx next dx rcgroupairconditioning NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans. NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans. Cooling Capacity: 6,4 97,4 next dx C rcgroupairconditioning R410 E C UP FLOW DOWN FLOW MIN FETURES

More information

... RTU Technical Manual. Packaged Air Conditioning Unit...

... RTU Technical Manual. Packaged Air Conditioning Unit... ... RTU Technical Manual Packaged Air Conditioning Unit... Index. CODING AND MODELS. WORKING LIMITS. TECHNICAL SPECIFICATIONS. PERFORMANCE TABLES. TECHNICAL SPECIFICATIONS FOR OPTIONAL EQUIPMENT. ELECTRONIC

More information

Air cooled chillers With axial fans and power ratings from 238 to 1600 kw with two-screw compressor

Air cooled chillers With axial fans and power ratings from 238 to 1600 kw with two-screw compressor NS Air cooled chillers With axial fans and power ratings from 238 to 1600 kw with two-screw compressor R134a Aermec adhere to the EUROVENT Certification program up to 600 kw. The products concerned appear

More information

RANGE. STD Version (Standard): HEE Version (High Energy Efficiency): OPERATION LIMITS. Series LP 46ºC 12ºC 18ºC 5ºC

RANGE. STD Version (Standard): HEE Version (High Energy Efficiency): OPERATION LIMITS. Series LP 46ºC 12ºC 18ºC 5ºC Cooling capacity: Heating capacity: 17,7 to 74,3 kw 21,8 to 84,8 kw Scroll compressors R-410A refrigerant Compact and silent design Cooling solution where an outdoor installation is impossible DESCRIPTION

More information

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING 199 RE ER RS SO AIR COOLED HEAT PUMP LIQUID CHILLERS 19,1 261,0 kw COOLING 23,7 333,0 kw HEATING R410A PLATE RCGROUP SpA 19632013 fiftycoolyears 200 VERSIONS: (R410A) Cooling capacity 19,2 261,0 kw Heating

More information

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C) Simple, reliable efficient heat pump! Equipped with µconnect controller HFC R410A CERTITA CERTIFIED * Cooling capacity: 5 to 16.5 kw Heating capacity: 6 to 19 kw *except 75HT OPTION HEAT PUMP HEATING (30/35

More information

CWP. Cooling Only Version (CO) Condenserless Version (RC) Heat Pump Version (HP) Models 02 to 35. Engineering Data Manual. Water Cooled Water Chillers

CWP. Cooling Only Version (CO) Condenserless Version (RC) Heat Pump Version (HP) Models 02 to 35. Engineering Data Manual. Water Cooled Water Chillers Engineering Data Manual Water Cooled Water Chillers Cooling Only Version () Condenserless Version () Heat Pump Version () Models 02 to 35 8 to 136 9 to 164 N IRWELL GROUP MPNY Specifications General The

More information

Multi-pipe units with scroll compressors

Multi-pipe units with scroll compressors Multi-pipe units with scroll compressors Model CMAB SE 050-525 Model CMAB HE 050-880 Cooling capacity: 45-779 kw Heating capacity: 49-881 kw CG-PRC044A-GB Table of Contents Product presentation...4 Operating

More information

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10 Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19

More information

CONTINUOUS CAPACITY CONTROL MODELS

CONTINUOUS CAPACITY CONTROL MODELS This series of air-cooled water chillers up to 400HP has been developed for various requirements of air conditioning systems and industrial chilled water systems, where these equipments are operated under

More information

AHN 064 to 304 EHN/CHN 064 to 304

AHN 064 to 304 EHN/CHN 064 to 304 u Horizontal Packaged and Split Air Conditioners AHN 64 to 34 EHN/CHN 64 to 34 6. to 29.2 kw 6.4 to 29.4 kw Engineering Data Manual EDM AECHN-A.1GB Date : June 28 Supersedes : None Technical Description

More information

CWP-CO / CWP-RC / CWP-HP 02 to 35

CWP-CO / CWP-RC / CWP-HP 02 to 35 Water Cooled Water Chillers Cooling Only, Condenserless and Heat Pump Versions - / - / - 02 to 35 8 to 136 9 to 164 Technical Brochure TM -N.4GB Date : March 2006 Supersedes : TM -N.3GB/05.04 Technical

More information

NECS-N. Climaveneta Technical Bulletin NECS_N_1314_3218_201003_GB. Air-to-water reversible heat pump with axial fans kw

NECS-N. Climaveneta Technical Bulletin NECS_N_1314_3218_201003_GB. Air-to-water reversible heat pump with axial fans kw Climaveneta Technical Bulletin NECS_N_1314_3218_201003_GB r HFC R-410A 1314-3218 339-792 kw Air-to-water reversible heat pump with axial fans (The photo of the unit is indicative and may change depending

More information

CGA CXA VGA VXA CG-PRC006-E4

CGA CXA VGA VXA CG-PRC006-E4 Cooling Only or Reversible Air Cooled Water Chiller CGA 075-100-120-150-200-240 CXA 075-100-120-150-200-240 VGA 075-100-120-150-200-240 VXA 075-100-120-150-200-240 Designed with your needs in mind TRANE

More information

kw. Kappa Rev. Air cooled modular screw chiller & heat pump. Bullet points. General. Configurations

kw. Kappa Rev. Air cooled modular screw chiller & heat pump. Bullet points. General. Configurations Kappa Rev Air cooled modular screw chiller & heat pump General High energy efficiency chillers with screw compressors also driven by inverter and shell&tube exchanger. Configurations HE: High efficiency

More information

kw. Kappa Rev. Air cooled modular screw chiller & heat pump. Bullet points. General. Configurations

kw. Kappa Rev. Air cooled modular screw chiller & heat pump. Bullet points. General. Configurations Kappa Rev Air cooled modular screw chiller & heat pump General High energy efficiency chillers with screw compressors also driven by inverter and shell&tube exchanger. Configurations HE: High efficiency

More information

FOCS. Climaveneta Technical Bulletin. Air-cooled water chiller with helical fans kw

FOCS. Climaveneta Technical Bulletin. Air-cooled water chiller with helical fans kw Climaveneta Technical Bulletin _1542_242_200909_GB 1542-242 277-51 kw Air-cooled water chiller with helical fans (The photo of the unit is indicative and may change depending on the model) Flexibility

More information

Air/Water chillers for outdoor installation Screw compressors, shell and tube heat exchangers and axial fans Cooling capacity kW 1402/9603

Air/Water chillers for outdoor installation Screw compressors, shell and tube heat exchangers and axial fans Cooling capacity kW 1402/9603 NEW NSM ir/water chillers for outdoor instation Screw compressors, shell and tube heat exchangers and axial fans ooling capacity 302 2100kW 1402/9603 cooling only R134a ermec participate in the EUROVENT

More information

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS 1 to 40 Nominal Tons Rev-01 TABLE OF CONTENTS Page: Description 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Product Nomenclature Air Cooled Chiller

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

NX 0152P P. Climaveneta Technical Bulletin NX 0152P P_201606_EN HCF R410A ELCA_Engine ver

NX 0152P P. Climaveneta Technical Bulletin NX 0152P P_201606_EN HCF R410A ELCA_Engine ver Climaveneta Technical Bulletin NX 0152P - 0812P 39,2-227 kw Chiller, air source for outdoor installation (The photo of the unit is indicative and may vary depending on the model) CLASS A EFFICIENCY ALUMINIUM

More information

Air Master BCP. Pool air handling units. Optimized energy consumption Electronic control. Description. Principle schemes

Air Master BCP. Pool air handling units. Optimized energy consumption Electronic control. Description. Principle schemes Cooling capacity: Heating capacity: 92,1 to 179,9 kw 69, to 148,7 kw Heating and dehumidification of covered pools Optimized energy consumption Electronic control Description Principle schemes The range

More information

Index Features and advantages... 3 General characteristics... 5 Nomenclature Technical specifications... 11

Index Features and advantages... 3 General characteristics... 5 Nomenclature Technical specifications... 11 Index Features and advantages... 3 Low operating cost... 3 Low operating sound levels... 3 Excellent serviceability... 3 Proven reliability... 3 Infinite capacity control... 3 Superior control logic...

More information

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL 1.1 SUMMARY A. Packaged Chillers offer a self-contained means of producing cooling liquid primarily

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9

More information

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA 1 of 10 Mattei rotary vane compressors are the result of 90 years of investments in research and development to improve performance and lessen the impact on the environment. Designed for industrial continuous

More information

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw)

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw) -P Series 50Hz Rooftop Units Cooling Capacity : to 388 MBH (8 to 407 kw) Heating Capacity : 8 to 98 MBH (8 to 380 kw) 40A Products that perform...by people who care NOMENCLATURE AC P S E 435 P HP G Q Air

More information

Electric expansion valve stepper motor. Controller for elec. expansion valve Connector for controller expansion valve

Electric expansion valve stepper motor. Controller for elec. expansion valve Connector for controller expansion valve Spare parts list Brand: Dimplex Type: LA Part number: 362330 Position 1 2 3 4 4.1 5 6 7 8 8 9 9 10 11 12 13 14 15 15/1 16 16/1 17 18 19 20 21 22 23 23 24 25 27 28 29 30 31 32 33 34 35 36 37 Description

More information

Inverter air to water heat pumps

Inverter air to water heat pumps Product Manual 504 B 07/07 A EN Date: July 2007 Supersedes: none Inverter air to water heat pumps McEnergy HPI 067.2 104.2 Cooling capacity from 249 to 385 kw Heating capacity from 274 to 412 kw Refrigerant:

More information

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons Product Catalog NQ Series Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons Page Intentionally Blank Contents Standard Features...1 Available Options...3 Oversized Pumps... 3 High Flow Unit

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS25 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 2 25 27 29 1 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 0 5 40 45 17 2.4 1.8 11. 22.2 1.4 11.9 21.1 12.9 12.2

More information

SyScroll Air EVO NEW

SyScroll Air EVO NEW Chiller Close Control Water terminals SyScroll 140-360 Air EVO NEW Air ed Water Chillers ing Only, Heat Pump and Total Heat Recovery Engineering Data Manual 136 to 340 kw 145 to 361 kw SyScroll Air Evo

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS35 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 25 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 35 40 45 17 34.1 21.1 11.4 32.5 20.4 11.7 30.8

More information

HWT 1402/9603. free cooling

HWT 1402/9603. free cooling irwater chillers for outdoor installation with free cooling Screw compressors, shell and tube heat exchangers and axial fans NSM Cooling capacity 306-2001kW HWT 14029603 free cooling HIGH EFFICIENCY LSO

More information

R134a Water Cooled Chillers. WCWWXT/Y Series ( Ton)

R134a Water Cooled Chillers. WCWWXT/Y Series ( Ton) R134a Water Cooled Chillers WCWWXT/Y Series (76-703 Ton) 1 INDEX Page General description 3 Versions 3 Technical features 3 Factory fitted accessories 3 Loose accessories 3 Reference conditions 3 Operating

More information

Product Catalog TSE Series Scroll Central Chillers

Product Catalog TSE Series Scroll Central Chillers Product Catalog TSE Series Scroll Central Chillers Contents Features...1 Available Options...3 Hot Gas Bypass Valve... 3 Rotary Non-Fused Disconnect Switch... 3 Integral Reservoir and Pumping System...

More information

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature

More information

TSE Series Central Chillers

TSE Series Central Chillers TSE Series Central s Dual Circuit Manifolds Included Dual circuit chillers include evaporator supply and return manifolds and water-cooled condenser units include condenser water supply and return manifolds

More information

Product Catalog TSE Series Scroll Central Chillers

Product Catalog TSE Series Scroll Central Chillers Product Catalog TSE Series Scroll Central Chillers Contents Features...1 Hot Gas Bypass Valve... 2 Rotary Non-Fused Disconnect Switch... 2 Integral Reservoir and Pumping System... 3 Remote Condenser Coil

More information

Chillers. EWAD-C- 620~1860 kw. Air-cooled R-134a. » Wide capacity range (620 kw kw) » Multiple efficiency and sound versions

Chillers. EWAD-C- 620~1860 kw. Air-cooled R-134a. » Wide capacity range (620 kw kw) » Multiple efficiency and sound versions Chillers Air-cooled R-134a» Wide capacity range (620 kw - 1860 kw)» Multiple efficiency and sound versions» Unique single screw compressor» Best-in-class energy efficiency (EER up to 3.70 and ESEER up

More information

Air Cooled CAPACITY: TR CHILLER PRODUCT DATA BOOK

Air Cooled CAPACITY: TR CHILLER PRODUCT DATA BOOK Air Cooled CHILLER CAPACITY: 25-206 TR 2 Company Business Awal Gulf Manufacturing, located at Bahrain is the one of the leading manufacturers of air conditioning and refrigeration products in Middle East

More information

ED.X Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS. COOLING CAPACITY FROM 6,7 TO 138 kw. ED.X 331 U Kc

ED.X Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS. COOLING CAPACITY FROM 6,7 TO 138 kw. ED.X 331 U Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS COOLING CAPACITY FROM 6,7 TO 138 kw ED.X 331 U Kc 6 The range of close control units with remote condenser, series ED.X, is particularly indicated

More information

TECS2. Climaveneta Technical Bulletin TECS2_0211_1154_201211_EN. High efficiency chiller, air source for outdoor installation kw

TECS2. Climaveneta Technical Bulletin TECS2_0211_1154_201211_EN. High efficiency chiller, air source for outdoor installation kw Climaveneta Technical Bulletin _0211_1154_201211_EN 0211-1154 233-1324 kw High efficiency chiller, air source for outdoor installation (The photo of the unit is indicative and may change depending on the

More information

RCD Air Cooled Condensing Unit (50/60 Hz)

RCD Air Cooled Condensing Unit (50/60 Hz) Environment friendly Easy to access components More efficient air cooled condenser coils Easy to install and maintain The Saudi Factory for Air Conditioning Units RCD Air Cooled Condensing Unit (50/60

More information

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

CLOSE CONTROL UNITS WITH CHILLED WATER COIL CLOSE CONTROL UNITS WITH CHILLED WATER COIL COOLING CAPACITY FROM 5 TO 154 kw 230 D 56 The range of chilled water close control units, series, is particularly indicated for use in technological centres,

More information

RCTM. Condensor, kw. RC Low up to 66 kw. RC Mid&High up to 1200 kw. Quick facts. General

RCTM. Condensor, kw. RC Low up to 66 kw. RC Mid&High up to 1200 kw. Quick facts. General TM Condensor, 8-1200 kw RC Low up to 66 kw RC Mid&High up to 1200 kw General RC is a series of robust and reliable aircooled remote condensors dedicated for air condition both for comfort and technical

More information

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR 4 Lmf Clima 6 FERRARO GROUP HRS Very high efficiency heat recovery units WITH HIGH EFFICIENCY HEAT RECOUPERATOR from 3 to 4. m³/h Air-handling unit designed and manufactured for nonresidential applications,

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

30-450kW. Now Available. Ultima Compact Chiller Range kW. > Ultima Compact Chiller Range. Free-Cooling models up to 450kW.

30-450kW. Now Available. Ultima Compact Chiller Range kW. > Ultima Compact Chiller Range. Free-Cooling models up to 450kW. 30-450kW 0-450kW Free-Cooling models up to 450kW Now Available > Ultima Compact Chiller Range Typical Applications > Precision Air Conditioning Cooling > Comfort Cooling > Process Cooling www.airedale.com

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

YCUJ Millennium TM AIR COOLED CONDENSING UNIT

YCUJ Millennium TM AIR COOLED CONDENSING UNIT YCUJ Millennium TM AIR COOLED CONDENSING UNIT REFRIGERANT R407C COOLING CAPACITIES 348 kw to 760 kw The YCUJ range of Condensing Units are designed for direct expansion cooling and are usually used in

More information

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized RATINGS 480 V - 60 Hz Standby kva 2187.50 KWe 1750 Prime kva 1989 KWe 1591 Benefits & features premium quality provides one source responsibility for the generating system and accessories The generator

More information

Conquest air-cooled chillers and heat pumps

Conquest air-cooled chillers and heat pumps Conquest air-cooled chillers and heat pumps Scroll compressor Model / 42-160 kw CG-PRC026A-E4 Introduction Trane is a leader in the air-cooled chillers marketplace, thanks to excellence in design and manufacturing.

More information

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized RATINGS 400 V - 50 Hz Standby kva 1100 KWe 880 Prime kva 1000 KWe 800 Benefits & features premium quality provides one source responsibility for the generating system and accessories The generator set,

More information

McQuay International WMC New Water Cooled Chiller with oil free centrifugal compressors

McQuay International WMC New Water Cooled Chiller with oil free centrifugal compressors McQuay International WMC New Water Cooled Chiller with oil free centrifugal compressors Applied Systems - Strategic Marketing Contents 1. Introducing WMC 1.1 Product Overview 2010 1.2 Range 2. Technical

More information

AIR COOLED CHILLERS WATER COOLED CHILLERS

AIR COOLED CHILLERS WATER COOLED CHILLERS AIR COOLED CHILLERS WATER COOLED CHILLERS STANDARD UNIT SPECIFICATIONS OF COMMERCIAL AIR COOLED CHILLERS General Description & Assembly Air Cooled Chillers are commercial packaged systems complete with

More information

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP VEP075N432K Job Name: Location: Schedule No.: System Designation: Engineer: Architect: Date: For: Reference Approval Review Construction FEATURES Two-pipe heat pump Hinged electrical box for ease of maintenance

More information