NEXTRON MONOBLOCK BURNERS kw
|
|
- Nancy Mitchell
- 5 years ago
- Views:
Transcription
1 NEXTRON MONOBLOCK BURNERS kw
2 MAIN CHARACTERISTICS OF THE RANGE Combustion Unique and efficient Developed and improved by ELCO R&D department, the Free Flame technology is a unique combustion process. This ELCO technology is capable to reach the NOx levels required by the most severe standards for all types of combustion chambers, whether they are 3-pass or reverse pass boilers. Design Smooth and integral The original design of NEXTRON range is the result of a successful integration between burner and ELCO technologies. NEXTRON burners are able to perfectly integrate themselves in any installation and professionals will appreciate the innovative construction that ease maintenance. Switch cabinet Built-in and modular All the NEXTRON burners feature integrated switch cabinet, the ISC System, with modular concept for control devices and accessories, including: adjusting and safety control box EMC protected power circuit of fan motor display with command keyboard in front of the panel The ISC System houses options and accessories, such as the power regulator and the frequency inverter (Variatron), and customizes each burner according to the installation needs.
3 Communication User-friendly and universal The adjusting and reading of the available information about the NEXTRON operation are possible through the MDE2 System, a display with a 5-buttons keyboard, by using pictograms and numerical data. This user-friendly language assures quick reading and total understanding, as ever before. Acoustic Comfort and compact The NEXTRON burner range offers a high acoustic comfort thanks to the Low Noise System. The unique air intake channel is carefully designed to achieve an acoustic level significantly lower than 8 db(a) up to 1 MW. This integrated and patented system on all NEXTRON burners is definitely a good replacement of the traditional bulky sound proofing box. Maintenance Simple and time saving The maintenance of the NEXTRON burner can be easily carried out thanks to a large opening of the above left side of its housing that offers an easy access to the whole combustion components. Thanks to the RTC System, the combustion components find again exactly the original position after the maintenance operations. Year after year, the RTC System grants high quality and reliable combustion on the NEXTRON range.
4 COMBUSTION CONTROL MAIN FEATURES Visualization and Remote Monitoring O 2 /CO Control Bus Interface BT 3 Variatron LEM/LCM 1 PID VSM 1 Electronic control Integrated and versatile The option "load controller" is in the form of a regulator mounted on the door of the switch cabinet and connected directly to the control box. With the help of three integrated modules in their cabinet, the NEXTRON 6 to 9 are able to: adjust the fan speed to the required flame power; monitor the combustion quality by analyzing the concentration of O 2 and CO in the flue gas; communicate remotely via an Ethernet network, as Modbus, Profibus or Ethernet.
5 DESIGNATION OF NEXTRON COMPONENTS Body Range N: NEXTRON Type 6, 7, 8, 9 Operation type Z 2 stages Z3 3 stages (light oil) V 2 stage progressive pneumatic R 2 stage progressive mechanical E 2 stage progressive electronic Combustion type - Standard (Class 2) F3 Low NOx - Free Flame U3 Low NOx - Diamond Head UF Low NOx - Diamond Head BB - N6. 24 G-EF3 / BT3 Component type BB: Burner body* Size Approximate power (kw) Fuel G Natural gas GL Dual fuel L Light oil Electrical equipment (integrated control box) /LFL Siemens LFL /BT3 Lamtec BT3 Combustion head Fuel G Natural gas GL Dual fuel L Light oil Operation type Z3 3 stages (light oil) V 2 stage progressive pneumatic R 2 stage progressive mechanical E 2 stage progressive electronic Combustion type - Standard (Class 1 or 2) F3 Low NOx - Free Flame U3 Low NOx - Diamond Head UF Low NOx - Diamond Head CH - G11EF31 - KN Component type CH: Combustion head* Platform 11 NEXTRON 6 12 NEXTRON 7 13 NEXTRON 8 14 NEXTRON 9 Series 1 N 1 2 N 2 3 N 3... N... Type KN short KM medium KL long Gas train Valve manufacturer d Dungs s Siemens Operation type 2 2 stages 3 2 stage progressive pneumatic 4 2 stage progressive electronic 5 2 stage progressive mechanical Gas train connection diameter 1 1/ or DN5... DN125 GT - d /2 - Rp 1 1/2 Component type GT: Gas train* Series 51 N 1 52 N 2... N N... Valve nominal diameter 1 1/ or DN5... DN125 * for invoice purposes only
6 TECHNICAL DATA GAS RANGE NEXTRON 6 7 G-E/G-V/G-R Low NOx Class 2 (< 12 mg/kwh) N6.24 G-E / G-V / G-R N6.29 G-E / G-V / G-R N7.36 G-E / G-V / G-R N7.45 G-E / G-V / G-R Burner output [kw] Gas pressure [mbar] Fan motor 4 V - 5/6 Hz - 3 kw 4 V - 5/6 Hz - 4 kw 4 V - 5/6 Hz - 5,5 kw 4 V - 5/6 Hz - 7,5 kw Auxiliary voltage 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz Power supply 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz Acoustic level [db(a)] < 7 < 71 < 74 < 75,5 dapa mbar N6.24 N6.29 N7.36 N kw NEXTRON 8 9 G-E Low NOx Class 2 (< 12 mg/kwh) N8.58 G-E N8.71 G-E N9.87 G-E N9.14 G-E Burner output [kw] Gas pressure [mbar] Fan motor 4 V - 5/6 Hz - 11 kw 4 V - 5/6 Hz - kw 4 V - 5/6 Hz - 18,5 kw 4 V - 5/6 Hz - 22 kw Auxiliary voltage 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz Power supply 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz Acoustic level [db(a)] < 77,5 < 78 < 8 < 82 dapa 3 3 mbar N8.58 N8.71 N9.87 N kw
7 TECHNICAL DATA GAS RANGE NEXTRON 6 7 G-EF3/G-VF3 Low NOx Class 3 (< 8 mg/kwh) N6.24 G-EF3 / G-VF3 N6.29 G-EF3 / G-VF3 N7.36 G-EF3 / G-VF3 N7.45 G-EF3 / G-VF3 Burner output [kw] Gas pressure [mbar] Fan motor 4 V - 5/6 Hz - 3 kw 4 V - 5/6 Hz - 4 kw 4 V - 5/6 Hz - 7,5 kw 4 V - 5/6 Hz - 7,5 kw Auxiliary voltage 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz Power supply 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz Acoustic level [db(a)] < 69 < 71 < 76 < 74 dapa mbar 12 9 N6.24 N6.29 N7.36 N kw NEXTRON 8 9 G-EU3 Low NOx Class 3 (< 8 mg/kwh) N8.58 G-EU3 N8.71 G-EU3 N9.87 G-EU3 N9.14 G-EU3 Burner output [kw] Gas pressure [mbar] Fan motor 4 V - 5/6 Hz - 11 kw 4 V - 5/6 Hz - kw 4 V - 5/6 Hz - 18,5 kw 4 V - 5/6 Hz - 22 kw Auxiliary voltage 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz Power supply 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz Acoustic level [db(a)] < 77,5 < 79,5 < 8 < 82 dapa 3 3 mbar N8.58 N8.71 N9.87 N kw
8 OVERALL DIMENSIONS GAS RANGE H A Al Ar B C D E ØG KN KM KL L Q N6 G-E/-V/-R N6 G-EF3/-VF N7 G-E/-V/-R N7 G-EF3/-VF N8 G-E N8 G-EU3 N9 G-E N9 G-EU , Connecting flange c (4x) Øa Øa b c f N6 G N6 G-...F M16 2 b N7 G N7 G-...F M f N8 G-... N8 G-EU M2 293 N9 G-... N9 G-EU M2 293 b
9 GAS TRAINS AND FILTERS GAS RANGE Siemens ±5 mm J K N6 N7 N8 N9 R S V V 1 * X AA* AB s1 1/ s s s s s Dungs ±5 mm J K N6 N7 N8 N9 R S V X AA* d1 1/ d1 1/ d d d d *: equipment for continuous operation (PED option) Filters Rp1 1/2 7 Rp2 5 Z ØD1 Z DN DN DN DN DN DN DN
10 TECHNICAL DATA DUAL FUEL RANGE NEXTRON 6 7 GL-RZ3 Low NOx Class 2 N6.24 GL-RZ3 N6.29 GL-RZ3 N7.36 GL-RZ3 N7.45 GL-RZ3 Burner output in gas [kw] Burner output in fuel [kw] Gas pressure [mbar] Fan motor 4 V - 5 Hz - 3 kw 4 V - 5 Hz - 4 kw 4 V - 5 Hz - 5,5 kw 4 V - 5 Hz - 7,5 kw Oil pump motor 4 V - 5 Hz -,55 kw 4 V - 5 Hz -,55 kw 4 V - 5 Hz -,74 kw 4 V - 5 Hz -,74 kw Auxiliary voltage 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz Power supply 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz Acoustic level [db(a)] < 7 < 71 < 74 < 75,5 dapa mbar 12 N6.24 N6.29 N7.36 N kw NEXTRON GL-E Low NOx Class 2 N6.24 GL-E N6.29 GL-E N7.36 GL-E N7.45 GL-E Burner output in gas [kw] Burner output in fuel [kw] Gas pressure [mbar] Fan motor 4 V - 5 Hz - 3 kw 4 V - 5 Hz - 4 kw 4 V - 5 Hz - 5,5 kw 4 V - 5 Hz - 7,5 kw Oil pump motor 4 V - 5 Hz -,74 kw 4 V - 5 Hz -,74 kw 4 V - 5 Hz - 1,1 kw 4 V - 5 Hz - 1,5 kw Auxiliary voltage 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz Power supply 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz Acoustic level [db(a)] < 7 < 71 < 74 < 75 N8.58 GL-E N8.71 GL-E N9.87 GL-E N9.14 GL-E Burner output in gas [kw] Burner output in fuel [kw] Gas pressure [mbar] Fan motor 4 V - 5 Hz - 11 kw 4 V - 5 Hz - kw 4 V - 5 Hz - 18,5 kw 4 V - 5 Hz - 22 kw Oil pump motor 4 V - 5 Hz - 3 kw 4 V - 5 Hz - 3 kw 4 V - 5 Hz - 3 kw 4 V - 5 Hz - 4 kw Auxiliary voltage 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz Power supply 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz Acoustic level [db(a)] < 77,5 < 79,5 < 81 < 82 dapa 3 3 mbar N6.24 N6.29 N7.45 N7.36 N8.58 N8.71 N9.87 N kw
11 TECHNICAL DATA DUAL FUEL RANGE NEXTRON 6 7 GL-EF3 Low NOx Class 3 N6.24 GL-EF3 N6.29 GL-EF3 N7.36 GL-EF3 N7.45 GL-EF3 Burner output in gas [kw] Burner output in fuel [kw] Gas pressure [mbar] Fan motor 4 V - 5 Hz - 3 kw 4 V - 5 Hz - 4 kw 4 V - 5 Hz - 7,5 kw 4 V - 5 Hz - 7,5 kw Oil pump motor 4 V - 5 Hz -,74 kw 4 V - 5 Hz -,74 kw 4 V - 5 Hz - 1,1 kw 4 V - 5 Hz - 1,5 kw Auxiliary voltage 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz Power supply 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz Acoustic level [db(a)] < 69 < 71 < 76 < 74 dapa mbar 12 9 N6.24 N6.29 N7.36 N kw NEXTRON 8 9 GL-EF3/GL-EUF Low NOx Class 3 N8.57 GL-EF3 N9.65 GL-EF3 N9.87 GL-EUF N9.14 GL-EUF Burner output in gas [kw] Burner output in fuel [kw] Gas pressure [mbar] Fan motor 4 V - 5 Hz - kw 4 V - 5 Hz - 22 kw 4 V - 5 Hz - 18,5 kw 4 V - 5 Hz - 22 kw Oil pump motor 4 V - 5 Hz - 3 kw 4 V - 5 Hz - 3 kw 4 V - 5 Hz - 3 kw 4 V - 5 Hz - 4 kw Auxiliary voltage 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz Power supply 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz Acoustic level [db(a)] < 8 < 83 < 81 < 82 dapa 3 3 mbar 25 2 N8.57 N9.65 N9.87 N kw
12 OVERALL DIMENSIONS DUAL FUEL RANGE A Al Ar B C D E ØG H KN KM KL N6... GL-RZ N6.24 GL-E N6.29 GL-E 31 N6... GL-EF N7.36 GL-RZ N7.45 GL-RZ N7.36 GL-E N7.45 GL-E N7... GL-EF N8.58 GL-E N8.71 GL-E N9... GL-E , N8.57 GL-EF N9.65 GL-EF , N9... GL-EUF , L Q Connecting flange b b f Øa c (4x) Øa b c f N6... GL-RZ M16 2 N6.24 GL-E 3-34 N6.29 GL-E M16 2 N6... GL-EF M16 2 N7.36 GL-RZ N7.45 GL-RZ M N7.36 GL-E 35-4 N7.45 GL-E M N7... GL-EF M N8.58 GL-E M2 293 N8.71 GL-E N9... GL-E M2 293 N8.57 GL-EF M2 293 N9.65 GL-EF N9... GL-EUF M2 293
13 GAS TRAINS AND FILTERS DUAL FUEL RANGE Siemens ±5 mm J K N6 N7 N8 N9 R S V V 1 * X AA* AB s1 1/ s s s s s Dungs ±5 mm J K N6 N7 N8 N9 R S V X AA* d1 1/ d1 1/ d d d d *: equipment for continuous operation (PED option) Filters Rp1 1/2 7 Rp2 5 Z ØD1 Z DN DN DN DN DN DN DN
14 TECHNICAL DATA LIGHT OIL RANGE NEXTRON 6 7 L-E Low NOx Class 2 (< 185 mg/kwh) N6.24 L-E N6.29 L-E N7.36 L-E N7.45 L-E Burner output [kw] Fuel Light oil EL 11,86 kwh/kg, maximum viscosity 6, mm²/s at 2 C Fan motor 4 V - 5 Hz - 3 kw 4 V - 5 Hz - 4 kw 4 V - 5 Hz - 5,5 kw 4 V - 5 Hz - 7,5 kw Oil pump motor 4 V - 5 Hz -,74 kw 4 V - 5 Hz -,74 kw 4 V - 5 Hz - 1,1 kw 4 V - 5 Hz - 1,5 kw Auxiliary voltage 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz Power supply 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz Acoustic level [db(a)] < 7 < 71 < 74 < 75 dapa mbar N6.24 N6.29 N7.36 N kw NEXTRON 8 9 L-E Low NOx Class 2 (< 185 mg/kwh) N8.58 L-E N8.71 L-E N9.87 L-E N9.14 L-E Burner output [kw] Fuel Light oil EL 11,86 kwh/kg, maximum viscosity 6, mm²/s at 2 C Fan motor 4 V - 5 Hz - 11 kw 4 V - 5 Hz - kw 4 V - 5 Hz - 18,5 kw 4 V - 5 Hz - 22 kw Oil pump motor 4 V - 5 Hz - 3 kw 4 V - 5 Hz - 3 kw 4 V - 5 Hz - 4 kw 4 V - 5 Hz - 4 kw Auxiliary voltage 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz Power supply 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz Acoustic level [db(a)] < 77,5 < 79,5 < 81 < 82 dapa 3 3 mbar N8.58 N8.71 N9.87 N kw
15 TECHNICAL DATA LIGHT OIL RANGE NEXTRON 6 7 L-EF3 Low NOx Class 3 (< 12 mg/kwh) N6.24 L-EF3 N6.29 L-EF3 N7.36 L-EF3 N7.45 L-EF3 Burner output [kw] Fuel Light oil EL 11,86 kwh/kg, maximum viscosity 6, mm²/s at 2 C Fan motor 4 V - 5 Hz - 3 kw 4 V - 5 Hz - 4 kw 4 V - 5 Hz - 7,5 kw 4 V - 5 Hz - 7,5 kw Oil pump motor 4 V - 5 Hz -,74 kw 4 V - 5 Hz -,74 kw 4 V - 5 Hz - 1,1 kw 4 V - 5 Hz - 1,5 kw Auxiliary voltage 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz Power supply 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz Acoustic level [db(a)] < 69 < 71 < 76 < 74 dapa mbar 12 9 N6.24 N6.29 N7.36 N kw NEXTRON 8 9 L-EF3/L-EUF Low NOx Class 3 (< 12 mg/kwh) N8.57 L-EF3 N9.65 L-EF3 N9.87 L-EUF N9.14 L-EUF Burner output [kw] Fuel Light oil EL 11,86 kwh/kg, maximum viscosity 6, mm²/s at 2 C Fan motor 4 V - 5 Hz - kw 4 V - 5 Hz - 22 kw 4 V - 5 Hz - 18,5 kw 4 V - 5 Hz - 22 kw Oil pump motor 4 V - 5 Hz - 3 kw 4 V - 5 Hz - 3 kw 4 V - 5 Hz - 3 kw 4 V - 5 Hz - 4 kw Auxiliary voltage 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz 1NPE AC 23 V - 5 Hz Power supply 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz 3NPE AC 4 V - 5 Hz Acoustic level [db(a)] < 8 < 83 < 81 < 82 dapa 3 3 mbar N8.57 N9.65 N9.87 N kw
16 OVERALL DIMENSIONS LIGHT OIL RANGE H A Al Ar B C E ØG KN KM KL N6.24 L-E N6.29 L-E N7.36 L-E N7.45 L-E N6.24 L-EF3 N6.29 L-EF N7.36 L-EF3 N7.45 L-EF Q 6 6 Connecting flange c (4x) Øa Øa b c f N6.24 L-E 3-34 N6.29 L-E M16 2 b N7.36 L-E 34-4 N7.45 L-E M f N6.24 L-EF3 N6.29 L-EF M16 2 N7.36 L-EF3 N7.45 L-EF M b
17 OVERALL DIMENSIONS LIGHT OIL RANGE H A Al Ar B C E ØG KN KM KL Q N8.58 L-E N8.71 L-E N9.87 L-E N9.14 L-E , N8.57 L-EF N9.65 L-EF3 431, N9.87 L-EUF N9.14 L-EUF , Connecting flange c (4x) Øa Øa b c f N8.58 L-E N8.71 L-E M2 293 b N9.87 L-E N9.14 L-E M2 293 f N8.57 L-EF N9.65 L-EF M2 293 N9.87 L-EUF N9.14 L-EUF M2 293 b
18 SUBSIDIARIES: GERMANY Dreieichstrasse, Mörfelden Walldorf Tel Fax Version /5/2 All rights reserved Subject to modifications NETHERLANDS Meerpaalweg, BB Almere P.O. box AA Almere Tel Fax ENGLAND Suite 3, The Crown House Blackpole East, Blackpole Road, Worcester WR3 8SG Tel Fax FRANCE 14, rue du Saule Trapu Parc d activité du Moulin Massy Tel Fax ITALY Viale Roma, Novara Tel Fax RUSSIA Eniseyskaya str. 1, bld 1, Office Center LIRA # Moscow Tel #57 Fax CHINA 17A2, V-Capital Bldg No. 333 Xian Xia Road 2336 Shanghai Tel Fax Contact us to know more about our products and solutions contact@elco-burners.com
Dual fuel burner NEXTRON 6 NEXTRON 7 NEXTRON 8 NEXTRON 9
I N D U S T R Y Dual fuel burner NEXTRON 6 NEXTRON 7 NEXTRON 8 NEXTRON 9 www.elco-burners.com Combustion Unique and efficient Developed and improved by elco R&D department, the Free Flame technology is
More informationGas burners NEXTRON 6 NEXTRON 7 NEXTRON 8 NEXTRON 9
I N D U S T R Y Gas urners NEXTRON 6 NEXTRON 7 NEXTRON 8 NEXTRON 9 www.elco-urners.com Comustion Unique and efficient Developed and improved y elco R&D department, the Free Flame technology is a unique
More informationGas burners EK EVO 6 EK EVO 7
I N D U S T R Y Gas burners EK EVO 6 EK EVO 7 www.elco-burners.com Design Robust and professional The design of the EK EVO is the result of a successful synergy between ELCO key features and essential
More informationMonoblock burners for heating, commercial and light industry applications
Monoblock burners for heating, commercial and light industry applications Technical information VECTRON G to G6 (,5 kw to 97 kw) VECTRON GL to GL6 (35 kw to 5 kw) VECTRON L to L6 (8 kw to 8 kw) www.elco-burners.com
More informationMonoblock burners for heating, commercial and light industry applications
Monoblock burners for heating, commercial and light industry applications Technical information VECTRON G to G6 (,5 kw to 97 kw) VECTRON GL to GL (35 kw to 6 kw) VECTRON L to L6 (8 kw to 8 kw) www.elco-burners.com
More informationMonoblock burners for heating, commercial and light industry applications
Monoblock burners for heating, commercial and light industry applications Technical information VECTRON G1 to G6 (14,5 kw to 1 97 kw) VECTRON L1 to L6 (18 kw to 8 kw) www.elco-burners.com VECTRON ELCO
More informationINDUSTRY CATALOGUE.
INDUSTRY CATALOGUE www.elco-burners.com INDUSTRY CATALOGUE THE COMPANY RANGE OVERVIEW EK EVO RANGE NEXTRON RANGE N1 RANGE HO-TRON RANGE GHO-TRON RANGE DUOBLOCK RANGE GAS TRAINS CONTROL UNITS OPTIONS p.
More informationPRODUCT RANGE
PRODUCT RANGE 2018 www.ecoflam-burners.com CUSTOMIZED BURNERS SOLUTIONS FOR ANY TYPE OF APPLICATION OUR EXPERIENCE Thanks to 45 years of experience in the design and production of burners, Ecoflam offers
More informationPRODUCT RANGE A COMPLETE RANGE OF BURNERS FROM 17 TO kw
www.ecoflam-burners.com PRODUCT RANGE 2015 A COMPLETE RANGE OF BURNERS FROM 17 TO 34000 kw CUTTING-EDGE BURNERS FOR HEATING AND INDUSTRIAL APPLICATIONS Our proposal Ecoflam offers a full range of blown
More informationOil, gas and dual fuel burners. Burner series
Oil, gas and dual fuel burners Burner series 350...450 Group 4B Capacity 700-5500 kw 1 2 Table of contents General 5 Light fuel oil burners 6 Dimensions and PI diagram 6 Technical data 7 Capacity/back
More informationRS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES
The RS/E-EV MZ burners series covers a firing range from 44 to 2650 kw, and it is based on a new Digital Burner Management System, Riello REC27, which is able to manage the air-fuel ratio by independent
More informationRL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw
LOW NOx T The RL/M BLU burners series covers a firing range from 360 to 1023 kw, and it has been designed for use in hot or superheated water boilers, hot air or steam generators and diathermic oil boilers.
More informationPRESS G SERIES. Two Stage Light Oil Burners FIRING RATES
The PRESS G series of burners covers a firing range from 107 to 1660 kw and they have been designed for use in civil installations of average dimensions, like building areas and large apartment groups
More informationONE STAGE GAS BURNERS RDBS SERIES
ONE STAGE GAS BURNERS RDBS SERIES 16 47 kw RDBS.1 16 47 kw The Riello RDBS is a new series of one stage gas burners with integrated gas train, characterised by its small dimensions in spite of its high
More informationRDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL
The Riello RDB series of one stage light oil and kerosene burners is available in eleven basic models, with an output ranging from 16,8 to 120 kw, in three different structures. The models are available
More informationOil, Gas and Dual Fuel Monoblock Burners
Capacity Oil, Gas and Dual Fuel Monoblock Burners 1-133 kw 1 Low Emission Combustion Technology Table of contents 2 Oilon Burners 8 Choosing the burner 9 NOx emissions 1 FGR - Flue Gas Recirculation 11
More informationCATALOGUE A complete range of burners for all fuels MONOBLOCK kw DUOBLOCK kw
CATALOGUE 2012 LIGHT OIL BURNERS HEAVY OIL BURNERS GAS BURNERS GAS/LIGHT OIL BURNERS GAS/HEAVY OIL BURNERS DUOBLOCK BURNERS A complete range of burners for all fuels MONOBLOCK 20-10 kw DUOBLOCK 350-20
More informationA E R Z E N S C R E W C O M P R E S S O R S
A E R Z E N S C R E W C O M P R E S S O R S New Aerzen Screw Compressor Units Delta Screw Generation 5 Intake volume flows from 270 m³/h up to 2.600 m³/h A E R Z E N E R M A S C H I N E N F A B R I K G
More informationPRESS P/N - P/N ECO SERIES
The PRESS P/N series of burners covers a firing range from 800 to 5130 kw. They have been designed in three versions for use in commercial and industrial installation, to burn different oil viscosity from
More informationRIELLO 40 GS SERIES. One Stage Gas Burners FIRING RATES. S kw S kw S kw S kw
The Riello 40 GS series of one stage gas burners, is a complete range of products developed to respond to any request for home heating. The Riello 40 GS series is available in four different models, with
More informationTWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw
TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO GS/M SERIES GS /M / 5 3/8 19 The Riello GS/M series of two stage progressive or modulating gas burners, is a complete range of products developed
More informationproduct Digital combustion technology Weishaupt oil burners, WL10 to WL40 ( kw) Information on compact burners
product Information on compact burners Digital combustion technology Weishaupt oil burners, WL1 to WL4 (3 7 kw) Hot for quality Technological progress is our motivation. It has been driving us for more
More informationTWO STAGE LIGHT OIL BURNERS PRESS G SERIES
TWO STAGE LIGHT OIL BURNERS PRESS G SERIES 7/178 356 kw PRESS 1G 13/19 534 kw PRESS 2G 214/356 712 kw PRESS 3G 273/534 1168 kw PRESS 4G 415/83 166 kw The PRESS G series of burners covers a firing range
More informationRIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw
The Riello 40 F series of one stage light oil burners, is a complete range of products developed to respond to any request for light industrial applications. The Riello 40 F series is available in three
More informationproduct Digital dual fuel burners Weishaupt dual fuel burners WGL30-C and WGL40-A ( kw) Information on compact burners
product Information on compact burners Digital dual fuel burners Weishaupt dual fuel burners WGL30-C and WGL40-A (70 550 kw) Hot for quality Ultra-modern research and production methods, rigorous quality
More informationproduct Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable
product Information on oil, gas and dual fuel burners Minimale Industrial Emissionswerte burners mit Gas Industrial burners 1, 11,7 kw flexible and reliable Weishaupt Industrial Burners: Flexible and reliable
More informationPower Plant and Process Burners
Power Plant and Process Burners Group 6 Capacity 6,800-273,000 MMBtu/h Power plants District heating plants Pulp and paper Chemical industry Metallurgic processes Municipal waste incineration Odorous gas
More informationRS/M SERIES. Modulating Gas Burners FIRING RATES
The RS/M burners series covers a firing range from 45 to 2650 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation
More informationRIELLO 40 FS SERIES. One Stage Gas Burners FIRING RATES. FS kw FS kw FS kw FS kw FS kw FS kw GAS
The Riello 40 FS series of one stage gas burners, is a complete range of products developed to respond to any request for light industrial application. The Riello 40 FS series is available in five different
More informationTightness control TC. Product brochure GB Edition 12.10
Tightness control TC Product brochure GB 3.1.5. Edition 1.10 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted
More informationinfo The intelligent control concept W-FM 100 and W-FM 200 combustion managers Information on digital combustion management
info Information on digital combustion management The intelligent control concept W-FM 100 and W-FM 200 combustion managers 2 Digital combustion management Modern gas, oil and dual fuel burners use combustion
More informationRS SERIES. Two Stage Progressive Gas Burners FIRING RATES
The RS burners series covers a firing range from 44 to 2290 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation
More informationVersatile and Powerful. Liduro Wind Frequency Converter System
Versatile and Powerful Liduro Wind LCW300-series The liquid-cooled Liduro Wind frequency converter systems from Liebherr have been specially developed for reliable operation in onshore and offshore wind
More informationGULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw.
The Riello Gulliver BS series of one stage gas burners, is a complete range of Low NOx emission products, developed to respond to any request for home heating, conforming to the most severe standards regarding
More informationTechnical specification agenitor 404b NG
Technical specification agenitor 404b NG Design: 100 kw el. 60 Hz / 480 V natural gas Calorific Value = 990 BTU/ft³ NOx < 1.0 g/bhp-h Exhaust cooling to 248 F Altitude 0 ft 1 / 9 1. Genset 3 1.1 Engine
More informationTechnical specification agenitor 408 NG
Technical specification agenitor 408 NG Design: 360 kw el. 60 Hz / 480 V natural gas Calorific Value = 990 BTU/ft³ NOx < 1,0 g/bhp-h Exhaust cooling to 248 F Altitude 0 ft 1 / 9 1. Genset 3 1.1 Engine
More informationTECHNICAL DATA LEAFLET GAS. RS/1 Series. One Stage Gas Burners. RS 34/1 MZ kw RS 44/1 MZ kw.
TECHNICAL DATA LEAFLET GAS RS/1 Series One Stage Gas Burners RS 34/1 MZ 7 39 kw RS 44/1 MZ 1 kw www.riello.com One Stage Gas Burners RS/1 Series The RS/1 series of burners covers a firing range from 7
More informationDoing more for clean environment and energy saving
Doing more for clean environment and energy saving Rütli Burners Switzerland AG is a worldwide leading industrial burner solution supplier. Our head quarter is located in Schaffhausen, Switzerland one
More informationRS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS
The RS/1 series of burners covers a firing range from 70 to 550 kw, and they have been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers.
More informationGULLIVER BSD SERIES. Low NOx Two Stage Gas Burners FIRING RATES. BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw.
The Riello Gulliver BSD series of two stage gas burners, is a complete range of Low NOx emission products, developed to respond to any request for home heating, conforming to the most severe standards
More informationLOW VOLTAGE WIND CONVERTERS. ABB wind turbine converters ACS880, 800 kw to 8 MW
LOW VOLTAGE WIND CONVERTERS ABB wind turbine converters ACS880, 800 kw to 8 MW 2 ABB WIND CONVERTERS, ACS880 WIND TURBINE CONVERTERS ACS880 wind turbine converter Flexible solution The ACS880 converter
More informationONE STAGE GAS BURNERS RS/1 SERIES RS 28/ kw RS 34/1 MZ kw RS 38/ kw RS 44/1 MZ kw
ONE STAGE GAS BURNERS RS/1 SERIES RS 28/1 163 349 kw RS 34/1 MZ 7 39 kw RS 38/1 232 465 kw RS 44/1 MZ 55 kw The RS/1 series of burners covers a firing range from 7 to 55 kw, and they have been designed
More informationTechnical specification agenitor 306 NG
Technical specification agenitor 306 NG Design: 250 kw el. 480 V / 60 Hz natural gas Calorific Value = 990 BTU/ft³ NOx < 1.0 g/bhp-h Exhaust cooling to 248 F 1 / 9 1. Genset 3 1.1 Engine 3 1.2 Generator
More informationproduct WM 20 for gas, oil, and dual-fuel WM 20 monarch burners ( kw) compact and powerful Information on gas, oil, and dual-fuel burners
product Information on gas, oil, and dual-fuel burners WM 20 for gas, oil, and dual-fuel WM 20 monarch burners (150 2600 kw) compact and powerful Progress and tradition: The latest monarch burner The monarch
More informationGas burner Dual fuel burner. Gas burner. Series RG GG MG. Dual fuel burner. Series MK
Gas burner Dual fuel burner Gas burner Series RG GG MG Dual fuel burner Series MK Series RG Fully automatic gas burner, tested and approved in accordance with DIN EN 676 suitable for the combustion of
More informationPRESSURIZED STEEL BOILER WITH REVERSED FLAME
smoke pipes PRESSURIZED STEEL BOILER WITH REVERSED FLAME OUTPUT RANGE from 340 to 7000 WORKING TEMPERATURE minimum return temperature 55 OPERATION WITH gas or oil fired jet burners MODELS 340 420 510 630
More informationTEMINOX GLS. Mono-/Duoblock Pressure Jet. Advantages. Capacity range Fuels
Mono-/Duoblock Pressure Jet TEMINOX GLS Advantages Highest quality standard by latest state of production engineering, application of ISO 9001 quality management system European type approval (EN 267 /
More informationproduct WM 30 for gas, oil, and dual-fuel WM 30 monarch burners ( kw) powerful and versatile Information on gas, oil, and dual-fuel burners
product Information on gas, oil, and dual-fuel burners WM 30 for gas, oil, and dual-fuel WM 30 monarch burners (350 6200 kw) powerful and versatile Progress and tradition: The latest monarch burner The
More informationproduct WM 20 for oil, gas and dual-fuel WM 20 monarch burners ( kw) compact and powerful Information on oil, gas and dual-fuel burners
product Information on oil, gas and dual-fuel burners WM 20 for oil, gas and dual-fuel WM 20 monarch burners (150 2600 kw) compact and powerful Progress and tradition: The latest monarch burner The monarch
More informationDB Series. Technical Data Leaflet. Industrial Dual Block Oil, Gas and Dual Fuel Burners. Industrial TS0086UK00
Technical Data Leaflet Industrial TS0086UK00 DB Series Industrial Dual Block Oil, Gas and Dual Fuel Burners DB 4 1000/2500 5000 kw DB 6 1400/4000 7800 kw DB 9 1500/5000 9500 kw DB 12 1700/7000 12500 kw
More informationSteam output 0.3 to 3.0 t/h Operating Pressure 10 to 16 bar
DATASHEET PSB SERIES Steam output 0.3 to 3.0 t/h Operating Pressure 10 to 16 bar Oil / Gas / HFO Fired Steam Boiler Three pass reverse flame steam boiler Without Economiser Maximum Permissible operating
More information3 Edition Product brochure GB AGA
TC AGA Tightness controls Adjustable test period which can be adapted to different systems Adjustable test instant allows quick system start Maximum safety thanks to self-monitoring electronics Product
More informationTWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw
TWO STAGE GAS BURNER GULLIVER RSD SERIES 160/208 345 kw The Riello Gulliver is a new model of the series of two stage gas burners, characterized for its small dimensions in spite of its high combustion
More informationMOBILAIR M 350. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 24.0 to 34.0 m³/min (850 to 1200 cfm)
MOBILAIR M 350 Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 24.0 to 34.0 m³/min (850 to 1200 cfm) www.kaeser.com MOBILAIR M 350 The powerful combination of the highly efficient
More informationJ920 FleXtra PowerPack
GE Power J920 FleXtra PowerPack fast and scalable power modules GE s Jenbacher J920 FleXtra PowerPack SCR box (optional) Ventilation outlet Genset enclosure V shape coolers Pre-installed ventilation and
More informationJM Aerofoil Multi-Stage 50 Hz
JM Aerofoil Multi-Stage 5 Hz JM AEROFOIL - MULTI-STAGE CONTENTS Page: JM Aerofoil Multi-Stage - Introduction -5 Multi-Staging Motor Frame Size Schedules - Three Phase 7-8 Performance Curves SK1- SK135
More informationproduct Compact and powerful Weishaupt monarch oil burner, WM-L20 ( kw) Information on oil burners
product Information on oil burners Compact and powerful Weishaupt monarch oil burner, WM-L20 (400 2600 kw) Progress and tradition: The new monarch oil burner For more than 50 years the monarch trademark
More informationDynamic climate chambers. MK MKF MKT MKFT series
Dynamic climate chambers MK MKF MKT MKFT series EN 2 Dynamic climate chambers from BINDER The basis for reliable material testing Whether confirming standards like IEC 68, MIL-STD 331, MIL-STD 810 or an
More informationReciprocating Compressors AIRBOX / AIRBOX CENTER
www.kaeser.com Reciprocating Compressors AIRBOX / AIRBOX CENTER Flow rate 0.25 to 0.90 m³/min, Pressure 7 10 12.5 bar What do users expect from a reciprocating compressor? The answer: They expect maximum
More informationavailable in battery up to 4 units for a total of 560 kw
MODULATING CONDENSING BOILER with double premix low NOx burner and double heat exchanger EXPANDABLE IN BATTERY for indoor and outdoor installations (IPX5D) OUTPUT RANGE from 10 to 560 kw (in battery) WORKING
More informationP a c k a g e s. One step ahead. Energy-efficient Reliable Compact Quiet
One step ahead. elta HYBRID P a c k a g e s Delta Hybrid Volume flows from 110 m3/h to 5800 m3/h (65 to 3,400 cfm) Pressures to 22 psig (1500 mbar) Vacuum to 21" Hg (-700mbar) Energy-efficient Reliable
More informationAC microline Range. High Precision Surface Finishing REDEFINING PRECISION IN SURFACE FINISHING. Fine Grinding / Lapping / Polishing
REDEFINING PRECISION IN SURFACE FINISHING Fine Grinding / Lapping / Polishing AC microline Range High Precision Surface Finishing www.peter-wolters.com Fine Grinding / Lapping / Polishing AC 470 Fast highly
More informationSmart design has its rewards. NEW! Thermo Scientific MSC-Advantage Class II Biological Safety Cabinet. Part of Thermo Fisher Scientific
Smart design has its rewards NEW! Thermo Scientific MSC-Advantage Class II Biological Safety Cabinet Part of Thermo Fisher Scientific MSC MSC-Advantage: Laboratories today are facing new challenges. Safety
More informationMotor Reliable & Technology Drives since 1922 GERMANY. FRANCE. NETHERLANDS. ITALY. SPAIN. RUSSIA. SINGAPORE
Motor Reliable & Technology Drives since 1922 GERMANY. FRANCE. NETHERLANDS. ITALY. SPAIN. RUSSIA. SINGAPORE Experience and Innovation since 3 Generations Johann Helmke 1889 1985 Founder of 1922 Ing. Johann
More informationinfo Increased capacity for industrial applications Weishaupt monarch gas burner WM-G10 version ZMI ( kw) Information on industrial burners
info Information on industrial burners Increased capacity for industrial applications Weishaupt monarch gas burner WM-G10 version ZMI (20 1250 kw) Weishaupt monarch burner WM-G10 ZMI Larger capacity in
More informationRS Series Two Stage Progressive Gas Burners
Technical Data Leaflet Gas TS0046UK06 RS Series Two Stage Progressive Gas s RS 34 MZ 70/130 390 kw RS 44 MZ 101/203 550 kw RS 50 116/290 580 kw RS 64 MZ 150/400 850 kw RS 70 192/465 814 kw RS 100 232/698
More informationLOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw
LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES 1/19 5 kw 35/4 91 kw 5/75 19 kw 11/14 4 kw The Riello Gulliver BSD series of two stage gas burners, is a complete range of Low NOx emission products, developed
More informationBio II Advance. Class II Biological Safety Cabinet
Bio II Advance Class II Biological Safety Cabinet Bio II Advance Class II Biological Safety Cabinet The Telstar Bio II Advance series is a new generation of biological safety cabinets providing a compact
More informationCentrifugal fan with highly efficient EC drive motor
Centrifugal fan with highly efficient EC drive motor simple and safe application and installation 2 Why HLU? 90 years of experience in the plastics processing market More than 10.000 m² production in Germany
More informationVIESMANN. Datasheet Part no.: see pricelist, price upon request Not suitable for sizing the boiler. For this, see the separate technical guide.
VIESMANN VITOMAX 200 HW Hot water boilers for permissible flow temperatures in excess of 120 C Three-pass boiler Combustion output 4.0 to 18.2 MW Datasheet Part no.: see pricelist, price upon request Not
More informationDevelopment test stands for E-motors
Development test stands for E-motors Standardized design for DC and EC/BLDC motors imc DCcompact & imc ECcompact standard test stands are well-proven and quickly available. imc productive testing www.imc-berlin.com/electric-motor-testing/
More informationMaximum productivity even on the most challenging sites.
Igo T Range Maximum productivity even on the most challenging sites www.manitowoccranes.com The Igo T range Successfully combining Power & Productivity Improving site productivity is a daily challenge.
More informationCustomized drive solutions
Customized drive solutions Low-Voltage Drive Systems Ready-to-use from 0.75 1200 kw schneider-electric.com/drives 2 schneider-electric.com/drives schneider-electric.com/drives 3 What will you get with
More informationSungrow-Samsung SDI ESS Solutions. April 12, 2017
Sungrow-Samsung SDI ESS Solutions April 12, 2017 Part 1 Sungrow-Samsung SDI Company Introduction Sungrow Company Culture Mission We are always devoting ourselves to Green and Effective, giving clean power
More informationHot Gas Tests. In-house Hot Gas Test Center Turn-key Hot Gas Test Benches
Hot Gas Tests In-house Hot Gas Test Center Turn-key Hot Gas Test Benches Hot Gas Tests Turn Key Hot Gas Test Bench for Thermal Testing of Exhaust Components Excellent services in hot gas testing combined
More informationViscoSense 3D. Viscosity & Density Measurement Enabling Mass Flow Measurement. Product Bulletin TO BE REALLY 1 SURE
ViscoSense 3D Viscosity & Density Measurement Enabling Mass Flow Measurement 774 Product Bulletin WWW.VAF.NL TO BE REALLY 1 SURE 1 Introduction Principle of operation Most of the operating costs of a ship
More informationABB central inverters PVS to 1000 kw
ABB central inverters PVS800 100 to 1000 kw ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators and end users who require
More informationSOLAR2PS 500 / 630 / 750 kw Three Phase Solar PV Inverter
SOLAR2PS 500 / 630 / 750 kw Three Phase Solar PV Inverter a new era connecting solar energy General Information Dynamic reactive power control Voltage Dip ride-through capability meets stringent requirements
More informationPre-announcement. Transformerless Solar Inverters
Pre-announcement Transformerless Solar Inverters Content About us 2 SOLIVIA - Solar inverters without transformer 4 Solar inverters for residential installations 6 SOLIVIA 3.0 TL 8 SOLIVIA 5.0 TL 10 Solar
More informationhighes flexibility technology performance security service
industrial burners performance service security technology flexibility 5 highes flexibility technology performance security service Customer satisfaction Customer satisfaction, the company mission since
More informationONE STAGE GAS BURNER GULLIVER RSF SERIES RS5F kw
ONE STAGE GAS BURNER GULLIVER RSF SERIES 160 330 kw The Riello Gulliver, is a new model of the series of one stage gas burners, developed to respond to any request for light industrial processes like bakery
More informationmeets mobility Oil-free compressor solutions for rail traffic
meets mobility Oil-free compressor solutions for rail traffic COMPETENCE Pantograph raising Operating the signal horn Application fields Pantograph raising Sanding systems Wheel flange lubrication Control
More informationit warms us up! PRICE LIST
warms us up! 09.2018 PRICE LIST Production Company Heiztechnik is a modern factory that produces boilers for burning solid fuels from 3,9 kw do 7 MW and complete container boiler rooms and other heating
More informationTS RANGE GAS, LIGHT OIL, HEAVY OIL AND DUAL FUEL DUOBLOCK BURNERS FROM 230 TO kw
www.ecolam-burners.com TS RAGE GAS, LIGHT IL, HEAVY IL AD DUAL FUEL DUBLCK BURERS FRM 23 T 34 kw TS RAGE CMPAY ur proposal Ecolam oers a ull range o blown air pressure jet burners granting high eiciency
More informationPower kva 9,3 10 Power kw 9,3 10 Rated Speed r.p.m Standard Voltage V 240 Rated at power factor Cos Phi 1
A10 WATER-COOLED SINGLE PHASE 50 HZ NON REQUIRED 97/68 DIESEL Generating Rates SERVICE PRP STANDBY Power kva 9,3 10 Power kw 9,3 10 Rated Speed r.p.m. 1.500 Standard Voltage V 240 Rated at power factor
More informationOil, Gas and Dual Fuel Burners
Oil, Gas and Dual Fuel Burners Burner series 130...150 50, 0 Group 3 Capacity 390-3,500 Table of contents General 1 How to choose a burner Light oil burners Technical data and dimensions 3- PI-diagrams
More informationTest lane for cars and vans. safelane BRAKE TESTER 204-RP
Test lane for cars and vans safelane BRAKE TESTER 204-RP SAFELANE 204-RP Test lanes to meet your individual requirements For more than 50 years the name of Hofmann has been a synonym for engineering and
More informationpag. 5 pag. 8 Who we are: evolution sectors pag. 11 pag. 14 Designation pag. 27 Versions pag. 18 pag. 31 Accessories and Options pag.
1 2 1 pag. 4 2 pag. 5 3 pag. 7 4 pag. 8 Who we are: evolution Introduction Industry sectors Plus & Benefit 5 pag. 10 6 pag. 11 7 pag. 12 8 pag. 14 Designation Compliance Directives and Standards Operating
More informationMilling spindles / H line Up to speed fast: Dynamic and robust for high loads
Milling spindles / H line Up to speed fast: Dynamic and robust for high loads SPINDLE TECHNOLOGY I SYSTEM TECHNOLOGY I DRIVE TECHNOLOGY I SERVICE SOLUTIONS www.kessler-group.biz Specialist partner KESSLER
More informationPotain MDT CITY. Range Brochure. Model Max. load Max. jib Tip load Mast Hoist. MDT98 6 t 55 m 1,2 t to 55 m 3,8-4,5 m 25 & 33 ch
Potain MDT CITY Range Brochure Model Max. load Max. jib Tip load Mast Hoist MDT98 6 t 55 m 1,2 t to 55 m 3,8-4,5 m 25 & 33 ch MDT128 6 t 55 m 1,6 t to 55 m 3,8-4,5 m 25, 33 & 50 ch MDT178 8 t 60 m 1,5
More informationIndustrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized
RATINGS 400 V - 50 Hz Standby kva 2250 KWe 1800 Prime kva 2045 KWe 1636 Benefits & features premium quality provides one source responsibility for the generating system and accessories The generator set,
More informationQuantum LMV. Low and Medium Voltage AC Induction Totally Enclosed Fan Cooled Motors. GE Power Conversion
GE Power Conversion Quantum LMV Low and Medium Voltage AC Induction Totally Enclosed Fan Cooled Motors NEMA 500 Frames IEC 315 Frames 200-800 HP 150-600 kw 2-12 Pole Ratings to Fit Your Applications NEMA
More informationinfo WK-series industrial burners Industrial burners WK40 to WK kw to 32,000 kw Information on Duoblock burners
info Information on Duoblock burners WK-series industrial burners Industrial burners WK40 to WK80 00 kw to 2,000 kw The powerful industrial burner with a modular construction arallel operation Air preheater
More informationProduct Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP
Product Information Stepper Motor-driven Diaphragm Dosing Pump Reliable dosing of chemicals Stepper motor driven diaphragm pumps are particularly suitable for highly accurate, reproducible industrial dosing
More informationProduct brochure. Medium voltage AC drive ACS 2000, kva, kv
Product brochure Medium voltage AC drive ACS 2000, 400 1000 kva, 6.0 6.9 kv 2 ACS 2000 brochure ABB ACS 2000 simple and reliable motor control The ACS 2000 is the latest member of the ABB medium voltage
More informationStandard Product Program. AirLINE & AirLINE Quick Type 8640 & Type 8644
Standard Product Program AirLINE & AirLINE Quick Type 8640 & Type 8644 2 Bürkert AirLINE standard product program 3 The AirLINE product program The standard product program provides a supplement to the
More informationWeishaupt Monarch oil burners Sizes 1 and 3 1/2002 GB
Weishaupt Monarch oil burners Sizes 1 and 3 1/ GB Description Weishaupt Monarch oil burners are of the fully automatic pressure atomising type. Their design has been carefully considered down to the smallest
More informationBio II Advance. Class II Biological Safety Cabinet
Bio II Advance Class II Biological Safety Cabinet Bio II Advance Class II Biological Safety Cabinet The Telstar Bio II Advance series is a new generation of biological safety cabinets providing a compact
More informationSilentFlo Hydraulic Power Units. Quiet, reliable and efficient power generation. be certain.
l SilentFlo Hydraulic Power Units Quiet, reliable and efficient power generation be certain. Reliable power from a proven source. Trust one of the world s leading providers of servohydraulic test systems
More informationFRM. Medium Pressure Regulator. Medium pressure regulator Type FRM
FRM Medium Pressure Regulator Medium pressure regulator Type FRM Direct acting pressure regulator with adjustable setpoint springs and modular mounted safety shutoff valve (SAV) In compliance with EN 334
More information