DIN CERTCO Alboinstraße Berlin Tel: Fax:
|
|
- Conrad Carr
- 5 years ago
- Views:
Transcription
1 Area (AG) length width Total nominal volume height width depth Auxiliary heated volume Electrical aux. heating power Page 1 of 8 Summary of EN SOLAR SYSTEM test results Annex to Solar KEYMARK Certificate Brand (optional) Ariston Thermo S.p.A. ARISTON Street Via A. Merloni 45 Postal Code Fabriano System classification Application(s) Hot water Solar loop, circulation principle Thermosyphon Direct solar loop / heat exchanger Heat exchanger Open, vented or closed solar loop Closed Drain back/down Store location Outdoor Store orientation (of main axis) Horizontal Type of auxiliary heating (internal backup heat) Electric If other auxiliary/internal backup heating, please specifiy: Solar+supplementary OR Solaronly / Solar preheat Solar only / Solar preheat Collector(s) Ariston Thermo S.p.A Keymark lic.no. if available 0117S2614 F Per module Licence Number Issued Country Tel. / Fax +39 Heat store(s) Ariston Thermo S.p.A Keymark lic.no. if available 0117S2256 A Italy public.relations@aristonthermo.com / 40 Store name Kairos CF2.01 m² mm mm CNA150HF CNA200HF CNA300HF litres mm mm mm litres kw Solar loop controller Keymark lic.no. if available Name Solar loop pump power range W Kairos CF2.01 to W Solar loop fluid Recommended/required Required Name water Freezing point C Number of collectors in each configuration for each store Store name CNA150HF CNA200HF CNA300HF Test report id. number Date of test report _EN_Sys; ; Because of reaching the limited faux value according to ISO 94595, a long term Version 3.6, Tel: Fax: info@dincertco.de
2 Page 2 of 8 Summary of EN test results Certification No. 0117S2256 A Annex to Solar KEYMARK Certificate Issued Ariston Thermo S.p.A. Country Italy Brand (optional) ARISTON Street Via A. Merloni 45 public.relations@aristonthermo.com Postal Code Fabriano Tel. / Fax / 40 Kairos CF2.01 CNA150HF CNA200HF CNA300HF Name of system configuration ARISTON KAIROS THERMO CF Kairos CF2.01 No. Collectors 1 Storage name CNA150HF Calculated annual results for "solaronly / preheat system" Daily drawoff 110 l Daily drawoff 140 l Daily drawoff 170 l Stockholm SE WürzburgDE Davos CH Athens GR f sol =Q L /Q d Solar fraction Ref. conditions Ta,ave Max. operating press. collector side 150 kpa Max. operating press. tank side 800 Test report id. number Date of test report _EN_Sys; ; ISO (DST) Because of reaching the limited faux value according to ISO 94595, a long term kpa All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 15 % Version 3.6, Tel: Fax: info@dincertco.de
3 Page 3 of 8 Summary of EN test results Certification No. 0117S2256 A Annex to Solar KEYMARK Certificate Issued Brand (optional) ARISTON Street Via A. Merloni 45 public.relations@aristonthermo.com Postal Code Fabriano Tel. / Fax / 40 CNA150HF CNA200HF CNA300HF Kairos CF Name of system configuration ARISTON KAIROS THERMO CF Kairos CF2.01 No. Collectors 1 Storage name CNA200HF Calculated annual results for "solaronly / preheat system" Daily drawoff 170 l Daily drawoff 200 l Daily drawoff 250 l Stockholm SE WürzburgDE Davos CH Athens GR f sol =Q L /Q d Solar fraction Max. operating press. collector side 150 kpa Max. operating press. tank side 800 kpa Date of test report ; ISO (DST) Because of reaching the limited faux value according to ISO 94595, a long term All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 15 % Version 3.6, Tel: Fax: info@dincertco.de
4 Page 4 of 8 Summary of EN test results Certification No. 0117S2256 A Annex to Solar KEYMARK Certificate Issued Brand (optional) ARISTON Street Via A. Merloni 45 public.relations@aristonthermo.com Postal Code Fabriano Tel. / Fax / 40 CNA150HF CNA200HF CNA300HF Kairos CF Name of system configuration ARISTON KAIROS THERMO CF Kairos CF2.01 No. Collectors 2 Storage name CNA300HF Calculated annual results for "solaronly / preheat system" Daily drawoff 250 l Daily drawoff 300 l Daily drawoff 400 l Stockholm SE WürzburgDE Davos CH Athens GR f sol =Q L /Q d Solar fraction Max. operating press. collector side 150 kpa Max. operating press. tank side 800 kpa Date of test report ; ISO (DST) Because of reaching the limited faux value according to ISO 94595, a long term All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 15 % Version 3.6, Tel: Fax: info@dincertco.de
5 Area (AG) length width Total nominal volume height width depth Auxiliary heated volume Electrical aux. heating power Page 5 of 8 Summary of EN SOLAR SYSTEM test results Licence Number 0117S2256 A Annex to Solar KEYMARK Certificate Issued Brand (optional) ARISTON Street Via A. Merloni 45 public.relations@aristonthermo.com Postal Code Fabriano Tel. / Fax / 40 System classification Application(s) Hot water Solar loop, circulation principle Thermosyphon Direct solar loop / heat exchanger Heat exchanger Open, vented or closed solar loop Closed Drain back/down Always filled (no drain) Store location Outdoor Store orientation (of main axis) Horizontal Type of auxiliary heating (internal backup heat) Electric If other auxiliary/internal backup heating, please specifiy: Solar+supplementary OR Solaronly / Solar preheat Solar only / Solar preheat Collector(s) Heat store(s) Ariston Thermo S.p.A Ariston Thermo S.p.A Keymark lic.no. if available 0117S2614 F Keymark lic.no. if available Per module Store name m² mm mm litres mm mm mm litres kw Kairos CF CNA150HFE CNA200HFE CNA300HFE Solar loop controller Solar loop fluid Keymark lic.no. if available Recommended/required Required Name Name water Solar loop pump power range W to W Freezing point C Kairos CF2.01 Number of collectors in each configuration for each store Store name CNA150HFE CNA200HFE CNA300HFE Date of test report ; Because of reaching the limited faux value according to ISO 94595, a long term Version 3.6, Tel: Fax: info@dincertco.de
6 Page 6 of 8 Summary of EN test results Certification No. 0117S2256 A Annex to Solar KEYMARK Certificate Issued Brand (optional) ARISTON Street Via A. Merloni 45 public.relations@aristonthermo.com Postal Code Fabriano Tel. / Fax / 40 CNA150HFE CNA200HFE CNA300HFE Kairos CF Name of system configuration ARISTON KAIROS THERMO CF1E 1501 Kairos CF2.01 No. Collectors 1 Storage name CNA150HFE Calculated annual results for "solaronly / preheat system" Daily drawoff 110 l Daily drawoff 140 l Daily drawoff 170 l Stockholm SE WürzburgDE Davos CH Athens GR f sol =Q L /Q d Solar fraction Max. operating press. collector side 150 kpa Max. operating press. tank side 800 kpa Date of test report ; ISO (DST) Because of reaching the limited faux value according to ISO 94595, a long term All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 15 % Version 3.6, Tel: Fax: info@dincertco.de
7 Page 7 of 8 Summary of EN test results Certification No. 0117S2256 A Annex to Solar KEYMARK Certificate Issued Brand (optional) ARISTON Street Via A. Merloni 45 public.relations@aristonthermo.com Postal Code Fabriano Tel. / Fax / 40 CNA150HFE CNA200HFE CNA300HFE Kairos CF Name of system configuration ARISTON KAIROS THERMO CF1E 2001 Kairos CF2.01 No. Collectors 1 Storage name CNA200HFE Calculated annual results for "solaronly / preheat system" Daily drawoff 170 l Daily drawoff 200 l Daily drawoff 250 l Stockholm SE WürzburgDE Davos CH Athens GR f sol =Q L /Q d Solar fraction Max. operating press. collector side 150 kpa Max. operating press. tank side 800 kpa Date of test report ; ISO (DST) Because of reaching the limited faux value according to ISO 94595, a long term All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 15 % Version 3.6, Tel: Fax: info@dincertco.de
8 Page 8 of 8 Summary of EN test results Certification No. 0117S2256 A Annex to Solar KEYMARK Certificate Issued Brand (optional) ARISTON Street Via A. Merloni 45 public.relations@aristonthermo.com Postal Code Fabriano Tel. / Fax / 40 CNA150HFE CNA200HFE CNA300HFE Kairos CF Name of system configuration ARISTON KAIROS THERMO CF1E 3001 Kairos CF2.01 No. Collectors 2 Storage name CNA300HFE Calculated annual results for "solaronly / preheat system" Daily drawoff 250 l Daily drawoff 300 l Daily drawoff 400 l Stockholm SE WürzburgDE Davos CH Athens GR f sol =Q L /Q d Solar fraction Max. operating press. collector side 150 kpa Max. operating press. tank side 800 kpa Date of test report ; ISO (DST) Because of reaching the limited faux value according to ISO 94595, a long term All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 15 % Version 3.6, Tel: Fax: info@dincertco.de
DIN CERTCO Alboinstraße Berlin Tel: Fax:
Area (AG) length width Total nominal volume height width depth Auxiliary heated volume Electrical aux. heating power Page 1 of 7 Summary of EN129762 SOLAR SYSTEM test results Annex to Solar KEYMARK Certificate
More informationAriston Thermo S.p.A Keymark lic.no. if available - Company. Store name. length. width. Gross CNA150HF CNA200HF CNA300HF. Company. Name.
Page 1 of 8 Summary of EN12976-2 SOLAR SYSTEM test results Annex to Solar KEYMARK Certificate Brand (optional) Ariston Thermo S.p.A. ARISTON KAIROS Street Via A. Merloni 45 Postal Code 60044 Fabriano Licence
More informationAnnex to Solar KEYMARK Certificate
Page 1 of 7 Summary of EN12976-2 SOLAR SYSTEM test results Annex to Solar KEYMARK Certificate Brand (optional) SAMMLER B. Michalopoulos sa Street 18 Chiou str. Aspropyrgos Ind. Zone Postal Code GR-19300
More informationAnnex to Solar KEYMARK Certificate
Page 1 of 7 Summary of EN12976-2 SOLAR SYSTEM test results Annex to Solar KEYMARK Certificate Brand (optional) Cirelius, Lda. Street Rua Inocencio Osorio L. Gondim, 103; ZI Avintes Postal Code PT-4430-662
More informationDIN CERTCO Alboinstraße Berlin Tel: Fax:
1 of Page Suary of EN12976-2 SOLAR SYSTEM test results Annex to Solar KEYMARK Certificate Licence Number Issued Brand (optional) Street Postal Code Country E-mail Tel. / Fax 17, Rue de la petite Baratte
More informationCERTIFICATE. Solar Keymark Certificate No. SP SC
CERTIFICATE Solar Keymark Certificate No. SP SC0895-2 Holder/Issued to/manufacturer : Jiangsu Micoe Solar Energy Co. Ltd Address: NingHai Industrial Zone, Lianyungang City, Jiangsu Province, China Product
More informationSummary of EN Test Results, Licence Number 011-7S471 R annex to Solar KEYMARK Certificate Issued
Summary of EN 12975 Test Results, Licence Number 011-7S471 R annex to Solar KEYMARK Certificate Issued 2014-08-28 Company holding the Brand (optional) Ako Tec Produktionsgesellschaft mbh Ako Tec Country
More informationSummary of EN Test Results, Licence Number 011-7S660 R annex to Solar KEYMARK Certificate Issued
Summary of EN 12975 Test Results, Licence Number 011-7S660 R annex to Solar KEYMARK Certificate Issued 2014-08-28 Company holding the Brand (optional) Ako Tec Produktionsgesellschaft mbh Ako Tec Country
More informationResults of annual simulation
2 x Vitosol 100-FM SVKF Total gross surface area:4,46 m² Azimuth: 0 Incl.: 30 160 Liters/Day 50 C Gas-fired boiler 26 kw Vitocell 100-B Vol : 250 l Results of annual simulation Installed collector power:
More informationNombre de modules. Number of modules. Kollektoranzahl. Bezeichnung. Modèle. Model. m² m m min - max litres mm mm litres
Summary EN 297 Test Results, Kurzfassung EN 297 Test Ergebnisse, Anlage zum Solar KEYMARK-Zertifikat Synthèse s résultas d'essais selon EN 297, Annexe au certificat Solar Register-Nr. s Zertifikat Numéro
More informationINSTALLATION MANUAL OF EZINC OPEN LOOP THERMO SIPHON SOLAR WATER HEATING SYSTEMS
INSTALLATION MANUAL OF EZINC OPEN LOOP THERMO SIPHON SOLAR WATER HEATING SYSTEMS 1) INTRODUCTION 2) GENERAL FEATURES 3) OPERATION INSTRUCTIONS 4) SUPPORT BASE AND MOUNTING STEPS 5) FITTINGS & CONNECTIONS
More informationExample printout. Building project. SDC Example. Dyfi Eco Park SY20 8AX Machynlleth UK. Mr C. Laughton Phone:
Building project SDC Example Dyfi Eco Park SY20 8AX Machynlleth UK Contact person: Mr C. Laughton Phone: 01654 700324 E-Mail: software@solardesign.co.uk Results of annual simulation Installed collector
More informationCOMPONENTS FOR SOLAR THERMAL SYSTEMS
COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending
More informationCALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB
Distribution manifold for radiant panel systems 664 series ACCREDITED CALEFFI 01260/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The distribution manifold for radiant panel systems is used to optimally
More informationSpecification Manual Ground Source Heat Pumps Northern Geo LLC 75 West Veum Appleton, MN
Specification Manual Ground Source Heat s www.northernheatpump.com Northern Geo LLC 75 West Veum Appleton, MN 56208 320-297-9100 info@northerngeo.com 07/30/2015 NL003 NorthStar Series Features & Benefits
More informationCALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/18 GB. replaces 01260/14 GB
Distribution manifold for radiant panel systems 664 series FM 21654 003 CALEFFI 01260/18 GB replaces 01260/14 GB Function The distribution manifold for radiant panel systems is used to optimally distribute
More informationDS Series Solar System
DS Series Solar System Permit information Consol 30-58-1800 Collector Flat mount on Colorsteel Plumdeck roofing Valve vent, Open loop http:// www.consolsolar.co.nz 21 Page 1 of This system is an evacuated
More informationPOINT OBSTRUCTION LIGHTS SOL LED SOLAR POWERED OBSTRUCTION SYSTEM
SOLAR POWERED OBSTRUCTION SYSTEM Compliances: ETL Listed to UL 1598 Wet Locations ETL Listed to CSA C22.2 No.250.0-04 Canada FAA Approved L-810 & L-864 by Advisory Circular 150/5345-43H Verified to ICAO
More informationSpecification Manual
Specification Manual Ground Source Heat s www.northernheatpump.com Northern Geo LLC 75 West Veum Appleton, MN 56208 320-297-9100 info@northerngeo.com 09/03/2014 NL003 NorthStar Series Features & Benefits
More informationSDHW System Inspection Form
SDHW System Inspection Form Project/Homeowner Name: Project #: Date: Contractor: Inspector: In Attendance: Approx Install Date: Type of System Closed Loop Drain Back Drain Down Thermosyphon Other Type
More informationCALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB.
Composite manifolds specifically designed for radiant panel systems 670 series FM 165 00 CALEFFI 0116/18 GB replaces dp 0116/11 GB Function Composite manifolds are used to control and distribute the medium
More informationRAFFAELLO SPARE PARTS CATALOGUE
RAFFAELLO SPARE PARTS CATALOGUE SUMMARY PAGE 1 PAGE 2 PAGE 3 PAGE 4 PAGE 5 PAGE 6 PAGE 7 PAGE 8 PAGE 9 PAGE 10 PAGE 11 PAGE 12 PAGE 13 GROUP GROUP BODY WORK BODY WORK BODY WORK Valve block PUMP Hot water
More informationsomething new in the air Technical Bulletin
something new in the air Technical Bulletin 2 Air Leaf 2 Air Leaf 3 Innova is a company operating in the renewable energy sector and develops advanced climatic comfort systems for every season. The technological
More informationOIL BURNERS. MINOR 1 Snorkel 240 Volt 50 Hz
OIL BURNERS MINOR 1 Snorkel 240 Volt 50 Hz 420010675700 04.06.2015 TECHNICAL DATA MODEL MINOR 1 SNORKEL Thermal power max kcal/h 25500 kw 29,6 Thermal power min kcal/h 17300 kw 20 Max capacity light oil
More informationCENTRIFUGAL FAN COIL UNIT VCE
CENTRIFUGAL FAN COIL UNIT VCE 0,51 kw 11,00 kw 0,85 kw 23,75 kw 129 m 3 /h 2003 m 3 /h VCE DESIGN QUALITY COMFORTRELIABILITY 3VERSION12 SIZE DESIGN VCEx0 vertical with cabinet Air intake: bottom vertical
More informationIntegrated temperature test and calibration bench Model CBS-SC4000
Calibration technology Integrated temperature test and calibration bench Model CBS-SC4000 WIKA data sheet CT 92.33 Applications Testing and calibration of temperature measuring instruments such as: - Mercury
More informationPilot Operated Pressure Relief Valve Series R5V (Denison)
Characteristics Pilot operated pressure relief valves series R5V have a similar design to the subplate mounted R4V series. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps
More informationMild Steel Dosing Pots
Mild Steel Dosing Pots Data Sheet Features Introduction Materials of Construction Most heating and chilled water systems require chemical dosing and the BOSS range of Dosing Pots provides a controlled
More informationTechnical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance
Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance MARINE DIESEL ENGINES D7.3L DI LD / D7.3L D-Tronic (Mercury MerCruiser D7.3L LD D-Tronic and D7.3L
More informationSKN_N0106AnnexJ_R2. Annex J - Specific requirements for PVT collector Certification. 1. Introduction and definition
Annex J - Specific requirements for PVT collector Certification 1. Introduction and definition PVT collectors (named hybrid collectors in ISO 9806) generate heat and electric power at the same time. They
More informationTechnical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance
Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance MARINE DIESEL ENGINES D4.2L IDI (Mercury MerCruiser D4.2L Model) IMPORTANT: To comply with regulations
More informationTechnical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance
Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance MARINE DIESEL ENGINES D4.2L 230 (4.2 MS 230 and 4.2 MI 230 Model) IMPORTANT: To comply with regulations
More information5" SUBMERSIBLE PUMPS _ed.12/2014. Single member - Company subject to the control and coordination of Franklin Electric Co., Inc.
Vertical S.r.l. via Asolo, 7 36031 Dueville (Vicenza) - Italy Tel. +39 0444 361114 Fax +39 0444 365247 P.IVA e C.F. 00558130241 e-mail: sales@vertical.vi.it www.etechpumps.com Single member - Company subject
More information5 x Solar Turbomach Taurus T60 (5.67MW ISO) Dual Fuel (Gas & HSD) Water Injection
Bargh afshan alborz Amol Mazandaran Iran Tel: +98 (0)1212229599 Fax: +98 (0)1213239001 Email: ba_alborz@yahoo.com www.alborzgenerator.com 5 x Solar Turbomach Taurus T60 (5.67MW ISO) Dual Fuel (Gas & HSD)
More informationKS Pump Stations. Engineering Submittal Sheet. Installation Sets for Collectors
Engineering Submittal Sheet Installation Sets for Collectors Layout legend S Supply from collector to storage R Return from storage to collector 1 Ball valve with thermometer and integrated gravity break
More informationExcel 10 (240 VAC, 1-phase, 60 Hz)
SWCC Summary Report Manufacturer: Wind Turbine Model: Certification Number: SWCC-10-12 Bergey Windpower Company Excel 10 (240 VAC, 1-phase, 60 Hz) The above-identified Small Wind Turbine is certified by
More informationMAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional
Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed
More informationTECHNICAL CATALOGUE AIR VENT VALVES AND SAFETY VALVES
TECHNICAL CATALOGUE AIR VENT VALVES AND SAFETY VALVES TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and distribution
More informationConverters. IndraDrive C HCS02
IndraDrive C HCS02 2 Bosch Rexroth AG Electric Drives and Controls Continuous output from 1.5 kw to 11 kw Overload capacity 2.5x Maximum current from 12 A to 70 A Can be connected to inverters for cost-effective
More informationTECHNICAL CATALOGUE DISTRIBUTION MANIFOLDS
TECHNICAL CATALOGUE DISTRIBUTION TEC ITAP SpA, founded in Lumezzane (Brescia) in 972, is currently one of the leading production companies in Italy of valves, fittings and distribution manifolds for plumbing
More informationTechnical Product Submittal
1. General Specifications 1.01 Certifications 1) SRCC OG-100 Technical Product Submittal Oventrop evacuated tube solar thermal collector OVSOL 5-8, 8 tube collector and OVSOL 5-16, 16 tube collector SRCC
More informationInnovo Condensing high efficiency water heater
Condensing high efficiency water heater IR 12-160/20-160/12-200/20-200/24-245/32-245/ 24-285/32-285/32-380 A Fully room-sealed condensing high efficiency water heater Automatic gas/air premix burning system
More informationCRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF FORCE METROLOGY:- CALIBRATION OF UNIAXIAL TESTING MACHINES
CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF FORCE METROLOGY:- CALIBRATION OF UNIAXIAL TESTING MACHINES Approved By: Chief Executive Officer: Ron Josias Executive - Accreditation: Mpho Phaloane
More informationCALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.
Pre-assembled distribution manifolds for heating and air-conditioning systems 663 series FM 21654 003 065/18 GB replaces dp 065/06 GB Function The pre-assembled distribution manifolds are designed to optimise
More informationFixed Displacement Bent Axis Axial Piston Pumps TPB 70 - TAP 70
HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES Certified Company ISO 9001:2015-14001:2015 ISO 9001:2015 Certificate N 12-Q-0200545-TIC ISO 14001:2015 Certificate N 12-E-0200545-TIC
More informationNCC Leisure Battery Verification Scheme. Leisure Accommodation Vehicles
The UK trade body for the caravan, motorhome, caravan holiday and park home industry. NCC Leisure Battery Verification Scheme Leisure Accommodation Vehicles Page 1 of 11 1 Scope The NCC Battery Verification
More informationConverters IndraDrive C (800) HCS02 Mechanical Electrical Pneumatic Hydraulic Control Motion CMA/Flodyne/Hydradyne of Courtesy
IndraDrive C HCS02 2 Bosch Rexroth AG Electric Drives and Controls Continuous output from 1.5 kw to 11 kw Overload capacity 2.5x Maximum current from 12 A to 70 A Can be connected to inverters for cost-effective
More informationenviko solar product brochure
enviko solar product brochure commercial & residential applications www.enviko.com Solar Thermal Evacuated Tube Collectors Top of the range, maximum efficiency solar evacuated tubes. Features These new
More informationHeat Exchangers & Enhanced Surface
Tru-Twist Technology! Product Catalog Edition l A wor ld leader in enhanced heat transfer technology. Coaxial Heat Exchangers & Enhanced Surface Geothermal Renewable Energy Turbotec Products, Inc. Water
More informationTechnical File Engine Model: MD706MX (4.2L 230) - MD706MS (4.2L 200)
Engine Model: MD706MX (4.2L 230) - MD706MS (4.2L 200) Contents: 1 Components, settings and operating values of the engine which influence its NO x emissions Page 2 2 Full range of allowable adjustments
More informationTransformer bushings, type GOH. Technical guide
Transformer bushings, type GOH Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required
More informationPRODUCT RANGE A COMPLETE RANGE OF BURNERS FROM 17 TO kw
www.ecoflam-burners.com PRODUCT RANGE 2015 A COMPLETE RANGE OF BURNERS FROM 17 TO 34000 kw CUTTING-EDGE BURNERS FOR HEATING AND INDUSTRIAL APPLICATIONS Our proposal Ecoflam offers a full range of blown
More information950x. Description. Part List
Via Circonvallazione, 308 Valduggia (VC), Italy Tel: +39 063 4789 Fax: +39 063 47895 950x Variable Orifice Bronze Double Regulating Valve valvoindustria ing.rizzio s.p.a. Description Variable orifice bronze
More informationISO INTERNATIONAL STANDARD. Earth-mover tyres and rims Part 3: Rims. Pneumatiques et jantes pour engins de terrassement Partie 3: Jantes
INTERNATIONAL STANDARD ISO 4250-3 Fourth edition 2011-05-01 Earth-mover tyres and rims Part 3: Rims Pneumatiques et jantes pour engins de terrassement Partie 3: Jantes Reference number ISO 4250-3:2011(E)
More informationGH Hydro Kits. Technical Information. Ref: N
GH Hydro Kits Ref: N-27167 0507 Technical Information Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT Certification Program. Products are as listed in the EUROVENT Directory
More informationManufacturer: Address: ZIP Code: City: Country: VAT #: Signatory, Name: Signatory, Title: Phone: Fax: WWW: Head of Engineering:
CERTIFICATION APPLICATION Reciprocating internal combustion engines Certificate No.: EX Exhaust emission measurement - Part 1: Test-bed measurement of gaseous and particulate exhaust emissions Ref.: ISO
More informationGUIDE FOR CHOOSING AN ACCUMULATOR TANK
GUIDE FOR CHOOSING AN ACCUMULATOR TANK Preliminary version 0.1 13.3.2006 TABLE OF CONTENTS 1 OVERVIEW.. 5 2 OPERATING PRINCIPLE.. 6 3 DIMENSIONS. 8 4 PRODUCT RANGE. 10 5 SPATIAL REQUIREMENTS.. 12 6 TECHNICAL
More informationDVGW Prüflaboratorium Gas DBI Gastechnologisches Institut ggmbh FREIBERG
Page: 2 of 10 Report No.: R e p o r t Contents: Page Test model 3 Applicable examinations 3 Explanations / characteristics 3 Countries / categories / inlet pressures 4 Technical data 5 Execution variants
More informationFlash Point Process Analyzer
Norms and standards ASTM D 56 ASTM D 93; DIN EN ISO 2719; IP 34 DIN EN ISO 13736; IP170 DIN 51755 Application The BARTEC BENKE Flash Point Process Analyzer (FPA-4) is a continuously measuring analyzer,
More informationEvacuated tube collectors
Evacuated tube collectors Evacuated tube collectors The overall performance of ecological heating systems based on solar thermal energy is significantly dependent on how efficiently the solar collector
More informationSOLAR AQUA. Operation and Installation Manual LDLINE AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP. Electronic Solar Control Center. for models CONTROLS INC.
AQUA SOLAR TM Electronic Solar Control Center Operation and Installation Manual for models AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP G LDLINE CONTROLS INC. www.goldlinecontrols.com 888-921-7665 IMPORTANT SAFETY
More informationCatch Eco Range : Technical Specification Sheet
Catch Eco Range : Technical Specification Sheet Battery Hybrid Inverter AC Coupled Inverter Lithium phosphate technology High cycle life with warrantied throughput Indoor and outdoor options (IP21 and
More informationPRESSURIZED STEEL BOILER WITH REVERSED FLAME
smoke pipes PRESSURIZED STEEL BOILER WITH REVERSED FLAME OUTPUT RANGE from 340 to 7000 WORKING TEMPERATURE minimum return temperature 55 OPERATION WITH gas or oil fired jet burners MODELS 340 420 510 630
More informationAF 300 HYDRAULIC DRILL RIG
AF 300 HYDRAULIC DRILL RIG IMT International S.p.A. was founded in 1974 by Mr. Giulio Accorroni. Since then, the Company has concentrated on the acquisition of specific know-how for the planning and construction
More informationNo. Date Items New Old Remarks. Regulations,EU certified Stage 3A Stage 2 from 2007~
Revised record SPC-S3L-272(2/9) No. Date Items New Old Remarks Regulations,EU certified Stage 3A Stage 2 from 2007~ 1 Jun.30.2006 Specifications S3L2-Z263SP addition Spec.table 6/9pages addition 2 Oct.26.2006
More informationISO INTERNATIONAL STANDARD. Wheelchairs Part 7: Measurement of seating and wheel dimensions
INTERNATIONAL STANDARD ISO 7176-7 First edition 1998-05-15 Wheelchairs Part 7: Measurement of seating and wheel dimensions Fauteuils roulants Partie 7: Mesurage des dimensions d'assise et des roues A Reference
More informationMAZDON. Table of Contents. Cautions. MAZDON Collector Tube Figure 1 Figure 2
Table of Contents MAZDON Cautions MAZDON Collector Tube Figure 1 Figure 2 Installation Procedure for MAZDON Sloping Roof (M) system Figure 3-6 Figure 7 Installation Procedure for MAZDON Sloping Roof (K)
More informationUTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management
Ductable units NEW Eco-Design Filter Air handling unit with high available static pressure V3000 control Fresh air management The range of air handling units is designed for suspended ceiling heating and
More informationCRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration)
CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration) Approved By: Chief Executive Officer: Ron Josias Executive - Accreditation: Mpho Phaloane Author:
More informationHELIUM SERIES COMPRESSOR SYSTEMS
HELIUM SERIES COMPRESSOR SYSTEMS Features a 1-year System and Block Warranty Jordair QC Program System Features: Block Features: ISO 9001:2008 Cert. 97-544 Balanced Design Low Oil Consumption CSA Cert.
More informationCOMPONENTS FOR SOLAR THERMAL SYSTEMS
COMPONENTS FOR SOLAR THERMAL SYSTEMS The Caleffi Solar product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending
More informationSMALL PROTECTIVE VENT
Accessories (Optional Parts) PMF-6B SMALL PROTECTIVE VENT Small and screw-in protective vent suitable for compact, and hand-held type devices. IP6 protection class (water depth meters / 60 mins) and -40
More informationReversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)
Simple, reliable efficient heat pump! Equipped with µconnect controller HFC R410A CERTITA CERTIFIED * Cooling capacity: 5 to 16.5 kw Heating capacity: 6 to 19 kw *except 75HT OPTION HEAT PUMP HEATING (30/35
More informationDate. Director c/o Petroleum Storage Program Manitoba Conservation and Water Stewardship 1007 Century Street Winnipeg, MB R3H 0W4
Date Director c/o Petroleum Storage Program Manitoba Conservation and Water Stewardship 1007 Century Street Winnipeg, MB R3H 0W4 To the Attention of the Director: Re: Insert Company Name Request for Variance
More informationCHANGE YOUR ENERGY CHARGE YOUR LIFE
Innovation for a Better Life CHANGE YOUR ENERGY CHARGE YOUR LIFE Compact Size & Easy Installation Proven Safety The compact and lightweight nature of the RESU allows easier and faster installation both
More informationCollectors suitable for Industrial Applications
Collectors suitable for Industrial Applications Werner Weiss AEE - Institute for Sustainable Technologies A-8200 Gleisdorf, Feldgasse 2 AUSTRIA Collector Overview Source: Elimar Frank - SPF What is a «Process
More informationTechnical Manual. Positive displacement lobe pump. Serie C - CF. Translation of the original instructions
Technical Manual Positive displacement lobe pump Serie C - CF Translation of the original instructions all the power with a delicate touch T.M. C-CF Series rev.1 05/2012 All rights reserved O.M.A.C. S.R.L.
More informationVIESMANN. Product parameters Product range Datasheet
VIESMANN Product parameters Product range 2013 Datasheet Productspecific parameters for calculating the energy efficiency requirement in building regulations Part L1 and L2 11/2013 Product parameters Introduction:
More informationCALEFFI. Modulating temperature regulating unit with distribution kit for primary circuit. 171 series 01153/15 GB. replaces 01153/07 GB
ACCREDITED Modulating temperature regulating unit with distribution kit for primary circuit 7 series ISO 9 FM 6 / GB replaces /7 GB Function The temperature regulating unit with the distribution kit for
More informationAQUA SOLAR. Operation and Installation Manual AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP. Electronic Solar Control Center. for models CON TROLS
AQUA SOLAR TM Electronic Solar Control Center Operation and Installation Manual for models AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP G LDLINE CON TROLS www.goldlinecontrols.com IMPORTANT SAFETY INSTRUCTIONS
More informationPHP-C Pressureless Expansion System Overview Description: The PHP-C balanced pressure expansion equipment is sized according to the total system volume and the boiler or chiller load. The PHP-C vessel
More informationMINI EXCAVATORS. Concrete solutions. Always ES 10 ZT. Operating weight kg Engine power 7,6 kw - 10,0 HP
MINI EXCAVATORS Concrete solutions. Always Operating weight 1.060 kg Engine power 7,6 kw - 10,0 HP 1 Its extremely compact size allow it to pass through narrow spots and to be used in tight spaces where
More informationAir Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.
Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water
More informationGASOKOL vacutube. GASOKOL GmbH, vacutube_de 1 von 5
Principle: Because of the warming up the fluid into the absorber pipe converts into steam, the vacuum into the circuit supports this process. The steam rises by its own incentive. The fluid liquefies into
More informationDVGW Prüflaboratorium Gas DBI Gastechnologisches Institut ggmbh FREIBERG
Page: 2 of 10 Report No. R e p o r t Contents: Page Test model 3 Applicable examinations 3 Explanations / characteristics 3 Countries / categories / inlet pressures 4 Technical data 5 Execution variants
More informationArt.918C Pre-assembled manifold with flow meters, air
TECHNICAL CATALOGUE Art.98C Pre-assembled manifold with flow meters, air vent valves and drain cock TEC ITAP SpA, founded in Lumezzane (Brescia) in 97, is currently one of the leading production companies
More informationSWCC Summary Report. Eveready Diversified Products (Pty) Ltd T/A Kestrel Renewable Energy. Certification Number: SWCC (240 VAC, 1-phase, 60 Hz)
SWCC Summary Report Manufacturer: Wind Turbine Model: Eveready Diversified Products (Pty) Ltd T/A Kestrel Renewable Energy Kestrel e400nb (240 VAC, 1-phase, 60 Hz) Certification Number: SWCC-10-16 The
More informationCased/Uncased Coils For Gas And Oil Furnaces
MODEL: TCF Cased/Uncased Coils For Gas And Oil Furnaces FORM NO. CSC-224 REV. 1 Sure Comfort TCF Cased/Uncased Coils For Gas And Oil Furnaces (TXV Metering Device Shown) Featuring Industry Standard R-410A
More informationCased/Uncased Coils For Gas And Oil Furnaces
Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCF- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] (TXV Metering Device Shown) Ruud Indoor
More informationCH 450. High Tech Line. Self-Erecting Hydraulic Piling Rig
CH 450 High Tech Line Self-Erecting Hydraulic Piling Rig CH 450 MULTIPURPOSE HYDRAULIC RIGS FOR DIFFERENT DRILLING TECHNOLOGIES. The winning solution for job sites that require fast operating times. Truly
More informationFluid Monitoring Station
Fluid Monitoring Station Executive Summary The Option Industries Fluid Monitoring Station (FMS) is a portable unit which monitors and records fluid rates and total volumes of water pulled from location.
More informationISO 9129 INTERNATIONAL STANDARD. Motorcycles Measurement methods for moments of inertia. Motocycles Méthodes de mesure des moments d'inertie
INTERNATIONAL STANDARD ISO 9129 Second edition 2008-05-15 Motorcycles Measurement methods for moments of inertia Motocycles Méthodes de mesure des moments d'inertie Reference number ISO 2008 PDF disclaimer
More informationDUO-TEC COMPACT SPARE PARTS CATALOGUE
DUO-TEC COMPACT SPARE PARTS CATALOGUE - Aprile 2016 - HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this
More informationRAMIRENT E19. Excavators Specifications. Dimensions
Dimensions (A) Blade height 235.0 mm (B) Clearance, upper structure to ground line 419.0 mm (C) Ground line to top of engine cover 1340.0 mm (D) Length of track on ground 1114.0 mm (E) Machine centre line
More informationVRF. Technical Data Book. Duct S for Europe (R410, 50Hz)
VRF Technical Data Book Duct S for Europe (R410, 50Hz) Version Modification Date Remark Ver.1.0 Release VRF DVM S IDU Duct S for Europe (R410A, 50Hz) TDB 14.09.22 Ver.1.1 External Pressure Minimum data
More informationHawaii Energy PY2015 PV WH. Standards & Specifications
Hawaii Energy PY2015 PV WH 1.1. PV WH SYSTEMS Solar systems installed under the Hawaii Energy Solar Water Heating Program ( the Program ) shall conform to applicable local building, plumbing and electrical
More informationCALEFFI. Direct supply unit for heating systems. 165 series 01237/17 GB. replaces dp 01237/15 GB. Function
Direct supply unit for heating systems 65 series ACCREDITED ISO 9 FM 65 CALEFFI 7/7 GB replaces dp 7/5 GB Function The direct supply unit performs the function of supplying the heating system circuits
More informationFan coil units MAJOR 2 CV/CH
CH 41 D CV 1 D MAJOR 2: Design and performance HEE impeller for increased performance Motor optional MAJOR 2 is a non-independant chilled and/or hot water supplied air conditioning Comfort unit for the
More informationHORIZONTAL MULTISTAGE PUMPS
ORIZONTA MUTISTAGE PUMPS INDEX E Stainless Steel orizontal Multistage Pump.... 2 General Product Curves.... 3 Material Table... 3 Table of hydraulic performances at - E 3-5 - 9...........................................................
More information6/2 ways/positions flow diverters
6/2 ways/positions flow diverters RE 18302-07/07.12 Replaces: 12.09 1/8 L753... (VS311-VS312-VS315) Size 10 Series 00 Maximum operating pressure 310 bar [4500 psi] Maximum flow 140 l/min [36,98 gpm] Ports
More information