DIN CERTCO Alboinstraße Berlin Tel: Fax:

Size: px
Start display at page:

Download "DIN CERTCO Alboinstraße Berlin Tel: Fax:"

Transcription

1 Area (AG) length width Total nominal volume height width depth Auxiliary heated volume Electrical aux. heating power Page 1 of 8 Summary of EN SOLAR SYSTEM test results Annex to Solar KEYMARK Certificate Brand (optional) Ariston Thermo S.p.A. ARISTON Street Via A. Merloni 45 Postal Code Fabriano System classification Application(s) Hot water Solar loop, circulation principle Thermosyphon Direct solar loop / heat exchanger Heat exchanger Open, vented or closed solar loop Closed Drain back/down Store location Outdoor Store orientation (of main axis) Horizontal Type of auxiliary heating (internal backup heat) Electric If other auxiliary/internal backup heating, please specifiy: Solar+supplementary OR Solaronly / Solar preheat Solar only / Solar preheat Collector(s) Ariston Thermo S.p.A Keymark lic.no. if available 0117S2614 F Per module Licence Number Issued Country Tel. / Fax +39 Heat store(s) Ariston Thermo S.p.A Keymark lic.no. if available 0117S2256 A Italy public.relations@aristonthermo.com / 40 Store name Kairos CF2.01 m² mm mm CNA150HF CNA200HF CNA300HF litres mm mm mm litres kw Solar loop controller Keymark lic.no. if available Name Solar loop pump power range W Kairos CF2.01 to W Solar loop fluid Recommended/required Required Name water Freezing point C Number of collectors in each configuration for each store Store name CNA150HF CNA200HF CNA300HF Test report id. number Date of test report _EN_Sys; ; Because of reaching the limited faux value according to ISO 94595, a long term Version 3.6, Tel: Fax: info@dincertco.de

2 Page 2 of 8 Summary of EN test results Certification No. 0117S2256 A Annex to Solar KEYMARK Certificate Issued Ariston Thermo S.p.A. Country Italy Brand (optional) ARISTON Street Via A. Merloni 45 public.relations@aristonthermo.com Postal Code Fabriano Tel. / Fax / 40 Kairos CF2.01 CNA150HF CNA200HF CNA300HF Name of system configuration ARISTON KAIROS THERMO CF Kairos CF2.01 No. Collectors 1 Storage name CNA150HF Calculated annual results for "solaronly / preheat system" Daily drawoff 110 l Daily drawoff 140 l Daily drawoff 170 l Stockholm SE WürzburgDE Davos CH Athens GR f sol =Q L /Q d Solar fraction Ref. conditions Ta,ave Max. operating press. collector side 150 kpa Max. operating press. tank side 800 Test report id. number Date of test report _EN_Sys; ; ISO (DST) Because of reaching the limited faux value according to ISO 94595, a long term kpa All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 15 % Version 3.6, Tel: Fax: info@dincertco.de

3 Page 3 of 8 Summary of EN test results Certification No. 0117S2256 A Annex to Solar KEYMARK Certificate Issued Brand (optional) ARISTON Street Via A. Merloni 45 public.relations@aristonthermo.com Postal Code Fabriano Tel. / Fax / 40 CNA150HF CNA200HF CNA300HF Kairos CF Name of system configuration ARISTON KAIROS THERMO CF Kairos CF2.01 No. Collectors 1 Storage name CNA200HF Calculated annual results for "solaronly / preheat system" Daily drawoff 170 l Daily drawoff 200 l Daily drawoff 250 l Stockholm SE WürzburgDE Davos CH Athens GR f sol =Q L /Q d Solar fraction Max. operating press. collector side 150 kpa Max. operating press. tank side 800 kpa Date of test report ; ISO (DST) Because of reaching the limited faux value according to ISO 94595, a long term All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 15 % Version 3.6, Tel: Fax: info@dincertco.de

4 Page 4 of 8 Summary of EN test results Certification No. 0117S2256 A Annex to Solar KEYMARK Certificate Issued Brand (optional) ARISTON Street Via A. Merloni 45 public.relations@aristonthermo.com Postal Code Fabriano Tel. / Fax / 40 CNA150HF CNA200HF CNA300HF Kairos CF Name of system configuration ARISTON KAIROS THERMO CF Kairos CF2.01 No. Collectors 2 Storage name CNA300HF Calculated annual results for "solaronly / preheat system" Daily drawoff 250 l Daily drawoff 300 l Daily drawoff 400 l Stockholm SE WürzburgDE Davos CH Athens GR f sol =Q L /Q d Solar fraction Max. operating press. collector side 150 kpa Max. operating press. tank side 800 kpa Date of test report ; ISO (DST) Because of reaching the limited faux value according to ISO 94595, a long term All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 15 % Version 3.6, Tel: Fax: info@dincertco.de

5 Area (AG) length width Total nominal volume height width depth Auxiliary heated volume Electrical aux. heating power Page 5 of 8 Summary of EN SOLAR SYSTEM test results Licence Number 0117S2256 A Annex to Solar KEYMARK Certificate Issued Brand (optional) ARISTON Street Via A. Merloni 45 public.relations@aristonthermo.com Postal Code Fabriano Tel. / Fax / 40 System classification Application(s) Hot water Solar loop, circulation principle Thermosyphon Direct solar loop / heat exchanger Heat exchanger Open, vented or closed solar loop Closed Drain back/down Always filled (no drain) Store location Outdoor Store orientation (of main axis) Horizontal Type of auxiliary heating (internal backup heat) Electric If other auxiliary/internal backup heating, please specifiy: Solar+supplementary OR Solaronly / Solar preheat Solar only / Solar preheat Collector(s) Heat store(s) Ariston Thermo S.p.A Ariston Thermo S.p.A Keymark lic.no. if available 0117S2614 F Keymark lic.no. if available Per module Store name m² mm mm litres mm mm mm litres kw Kairos CF CNA150HFE CNA200HFE CNA300HFE Solar loop controller Solar loop fluid Keymark lic.no. if available Recommended/required Required Name Name water Solar loop pump power range W to W Freezing point C Kairos CF2.01 Number of collectors in each configuration for each store Store name CNA150HFE CNA200HFE CNA300HFE Date of test report ; Because of reaching the limited faux value according to ISO 94595, a long term Version 3.6, Tel: Fax: info@dincertco.de

6 Page 6 of 8 Summary of EN test results Certification No. 0117S2256 A Annex to Solar KEYMARK Certificate Issued Brand (optional) ARISTON Street Via A. Merloni 45 public.relations@aristonthermo.com Postal Code Fabriano Tel. / Fax / 40 CNA150HFE CNA200HFE CNA300HFE Kairos CF Name of system configuration ARISTON KAIROS THERMO CF1E 1501 Kairos CF2.01 No. Collectors 1 Storage name CNA150HFE Calculated annual results for "solaronly / preheat system" Daily drawoff 110 l Daily drawoff 140 l Daily drawoff 170 l Stockholm SE WürzburgDE Davos CH Athens GR f sol =Q L /Q d Solar fraction Max. operating press. collector side 150 kpa Max. operating press. tank side 800 kpa Date of test report ; ISO (DST) Because of reaching the limited faux value according to ISO 94595, a long term All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 15 % Version 3.6, Tel: Fax: info@dincertco.de

7 Page 7 of 8 Summary of EN test results Certification No. 0117S2256 A Annex to Solar KEYMARK Certificate Issued Brand (optional) ARISTON Street Via A. Merloni 45 public.relations@aristonthermo.com Postal Code Fabriano Tel. / Fax / 40 CNA150HFE CNA200HFE CNA300HFE Kairos CF Name of system configuration ARISTON KAIROS THERMO CF1E 2001 Kairos CF2.01 No. Collectors 1 Storage name CNA200HFE Calculated annual results for "solaronly / preheat system" Daily drawoff 170 l Daily drawoff 200 l Daily drawoff 250 l Stockholm SE WürzburgDE Davos CH Athens GR f sol =Q L /Q d Solar fraction Max. operating press. collector side 150 kpa Max. operating press. tank side 800 kpa Date of test report ; ISO (DST) Because of reaching the limited faux value according to ISO 94595, a long term All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 15 % Version 3.6, Tel: Fax: info@dincertco.de

8 Page 8 of 8 Summary of EN test results Certification No. 0117S2256 A Annex to Solar KEYMARK Certificate Issued Brand (optional) ARISTON Street Via A. Merloni 45 public.relations@aristonthermo.com Postal Code Fabriano Tel. / Fax / 40 CNA150HFE CNA200HFE CNA300HFE Kairos CF Name of system configuration ARISTON KAIROS THERMO CF1E 3001 Kairos CF2.01 No. Collectors 2 Storage name CNA300HFE Calculated annual results for "solaronly / preheat system" Daily drawoff 250 l Daily drawoff 300 l Daily drawoff 400 l Stockholm SE WürzburgDE Davos CH Athens GR f sol =Q L /Q d Solar fraction Max. operating press. collector side 150 kpa Max. operating press. tank side 800 kpa Date of test report ; ISO (DST) Because of reaching the limited faux value according to ISO 94595, a long term All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 15 % Version 3.6, Tel: Fax: info@dincertco.de

DIN CERTCO Alboinstraße Berlin Tel: Fax:

DIN CERTCO Alboinstraße Berlin Tel: Fax: Area (AG) length width Total nominal volume height width depth Auxiliary heated volume Electrical aux. heating power Page 1 of 7 Summary of EN129762 SOLAR SYSTEM test results Annex to Solar KEYMARK Certificate

More information

Ariston Thermo S.p.A Keymark lic.no. if available - Company. Store name. length. width. Gross CNA150HF CNA200HF CNA300HF. Company. Name.

Ariston Thermo S.p.A Keymark lic.no. if available - Company. Store name. length. width. Gross CNA150HF CNA200HF CNA300HF. Company. Name. Page 1 of 8 Summary of EN12976-2 SOLAR SYSTEM test results Annex to Solar KEYMARK Certificate Brand (optional) Ariston Thermo S.p.A. ARISTON KAIROS Street Via A. Merloni 45 Postal Code 60044 Fabriano Licence

More information

Annex to Solar KEYMARK Certificate

Annex to Solar KEYMARK Certificate Page 1 of 7 Summary of EN12976-2 SOLAR SYSTEM test results Annex to Solar KEYMARK Certificate Brand (optional) SAMMLER B. Michalopoulos sa Street 18 Chiou str. Aspropyrgos Ind. Zone Postal Code GR-19300

More information

Annex to Solar KEYMARK Certificate

Annex to Solar KEYMARK Certificate Page 1 of 7 Summary of EN12976-2 SOLAR SYSTEM test results Annex to Solar KEYMARK Certificate Brand (optional) Cirelius, Lda. Street Rua Inocencio Osorio L. Gondim, 103; ZI Avintes Postal Code PT-4430-662

More information

DIN CERTCO Alboinstraße Berlin Tel: Fax:

DIN CERTCO Alboinstraße Berlin Tel: Fax: 1 of Page Suary of EN12976-2 SOLAR SYSTEM test results Annex to Solar KEYMARK Certificate Licence Number Issued Brand (optional) Street Postal Code Country E-mail Tel. / Fax 17, Rue de la petite Baratte

More information

CERTIFICATE. Solar Keymark Certificate No. SP SC

CERTIFICATE. Solar Keymark Certificate No. SP SC CERTIFICATE Solar Keymark Certificate No. SP SC0895-2 Holder/Issued to/manufacturer : Jiangsu Micoe Solar Energy Co. Ltd Address: NingHai Industrial Zone, Lianyungang City, Jiangsu Province, China Product

More information

Summary of EN Test Results, Licence Number 011-7S471 R annex to Solar KEYMARK Certificate Issued

Summary of EN Test Results, Licence Number 011-7S471 R annex to Solar KEYMARK Certificate Issued Summary of EN 12975 Test Results, Licence Number 011-7S471 R annex to Solar KEYMARK Certificate Issued 2014-08-28 Company holding the Brand (optional) Ako Tec Produktionsgesellschaft mbh Ako Tec Country

More information

Summary of EN Test Results, Licence Number 011-7S660 R annex to Solar KEYMARK Certificate Issued

Summary of EN Test Results, Licence Number 011-7S660 R annex to Solar KEYMARK Certificate Issued Summary of EN 12975 Test Results, Licence Number 011-7S660 R annex to Solar KEYMARK Certificate Issued 2014-08-28 Company holding the Brand (optional) Ako Tec Produktionsgesellschaft mbh Ako Tec Country

More information

Results of annual simulation

Results of annual simulation 2 x Vitosol 100-FM SVKF Total gross surface area:4,46 m² Azimuth: 0 Incl.: 30 160 Liters/Day 50 C Gas-fired boiler 26 kw Vitocell 100-B Vol : 250 l Results of annual simulation Installed collector power:

More information

Nombre de modules. Number of modules. Kollektoranzahl. Bezeichnung. Modèle. Model. m² m m min - max litres mm mm litres

Nombre de modules. Number of modules. Kollektoranzahl. Bezeichnung. Modèle. Model. m² m m min - max litres mm mm litres Summary EN 297 Test Results, Kurzfassung EN 297 Test Ergebnisse, Anlage zum Solar KEYMARK-Zertifikat Synthèse s résultas d'essais selon EN 297, Annexe au certificat Solar Register-Nr. s Zertifikat Numéro

More information

INSTALLATION MANUAL OF EZINC OPEN LOOP THERMO SIPHON SOLAR WATER HEATING SYSTEMS

INSTALLATION MANUAL OF EZINC OPEN LOOP THERMO SIPHON SOLAR WATER HEATING SYSTEMS INSTALLATION MANUAL OF EZINC OPEN LOOP THERMO SIPHON SOLAR WATER HEATING SYSTEMS 1) INTRODUCTION 2) GENERAL FEATURES 3) OPERATION INSTRUCTIONS 4) SUPPORT BASE AND MOUNTING STEPS 5) FITTINGS & CONNECTIONS

More information

Example printout. Building project. SDC Example. Dyfi Eco Park SY20 8AX Machynlleth UK. Mr C. Laughton Phone:

Example printout. Building project. SDC Example. Dyfi Eco Park SY20 8AX Machynlleth UK. Mr C. Laughton Phone: Building project SDC Example Dyfi Eco Park SY20 8AX Machynlleth UK Contact person: Mr C. Laughton Phone: 01654 700324 E-Mail: software@solardesign.co.uk Results of annual simulation Installed collector

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB Distribution manifold for radiant panel systems 664 series ACCREDITED CALEFFI 01260/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The distribution manifold for radiant panel systems is used to optimally

More information

Specification Manual Ground Source Heat Pumps Northern Geo LLC 75 West Veum Appleton, MN

Specification Manual Ground Source Heat Pumps Northern Geo LLC 75 West Veum Appleton, MN Specification Manual Ground Source Heat s www.northernheatpump.com Northern Geo LLC 75 West Veum Appleton, MN 56208 320-297-9100 info@northerngeo.com 07/30/2015 NL003 NorthStar Series Features & Benefits

More information

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/18 GB. replaces 01260/14 GB

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/18 GB. replaces 01260/14 GB Distribution manifold for radiant panel systems 664 series FM 21654 003 CALEFFI 01260/18 GB replaces 01260/14 GB Function The distribution manifold for radiant panel systems is used to optimally distribute

More information

DS Series Solar System

DS Series Solar System DS Series Solar System Permit information Consol 30-58-1800 Collector Flat mount on Colorsteel Plumdeck roofing Valve vent, Open loop http:// www.consolsolar.co.nz 21 Page 1 of This system is an evacuated

More information

POINT OBSTRUCTION LIGHTS SOL LED SOLAR POWERED OBSTRUCTION SYSTEM

POINT OBSTRUCTION LIGHTS SOL LED SOLAR POWERED OBSTRUCTION SYSTEM SOLAR POWERED OBSTRUCTION SYSTEM Compliances: ETL Listed to UL 1598 Wet Locations ETL Listed to CSA C22.2 No.250.0-04 Canada FAA Approved L-810 & L-864 by Advisory Circular 150/5345-43H Verified to ICAO

More information

Specification Manual

Specification Manual Specification Manual Ground Source Heat s www.northernheatpump.com Northern Geo LLC 75 West Veum Appleton, MN 56208 320-297-9100 info@northerngeo.com 09/03/2014 NL003 NorthStar Series Features & Benefits

More information

SDHW System Inspection Form

SDHW System Inspection Form SDHW System Inspection Form Project/Homeowner Name: Project #: Date: Contractor: Inspector: In Attendance: Approx Install Date: Type of System Closed Loop Drain Back Drain Down Thermosyphon Other Type

More information

CALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB.

CALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB. Composite manifolds specifically designed for radiant panel systems 670 series FM 165 00 CALEFFI 0116/18 GB replaces dp 0116/11 GB Function Composite manifolds are used to control and distribute the medium

More information

RAFFAELLO SPARE PARTS CATALOGUE

RAFFAELLO SPARE PARTS CATALOGUE RAFFAELLO SPARE PARTS CATALOGUE SUMMARY PAGE 1 PAGE 2 PAGE 3 PAGE 4 PAGE 5 PAGE 6 PAGE 7 PAGE 8 PAGE 9 PAGE 10 PAGE 11 PAGE 12 PAGE 13 GROUP GROUP BODY WORK BODY WORK BODY WORK Valve block PUMP Hot water

More information

something new in the air Technical Bulletin

something new in the air Technical Bulletin something new in the air Technical Bulletin 2 Air Leaf 2 Air Leaf 3 Innova is a company operating in the renewable energy sector and develops advanced climatic comfort systems for every season. The technological

More information

OIL BURNERS. MINOR 1 Snorkel 240 Volt 50 Hz

OIL BURNERS. MINOR 1 Snorkel 240 Volt 50 Hz OIL BURNERS MINOR 1 Snorkel 240 Volt 50 Hz 420010675700 04.06.2015 TECHNICAL DATA MODEL MINOR 1 SNORKEL Thermal power max kcal/h 25500 kw 29,6 Thermal power min kcal/h 17300 kw 20 Max capacity light oil

More information

CENTRIFUGAL FAN COIL UNIT VCE

CENTRIFUGAL FAN COIL UNIT VCE CENTRIFUGAL FAN COIL UNIT VCE 0,51 kw 11,00 kw 0,85 kw 23,75 kw 129 m 3 /h 2003 m 3 /h VCE DESIGN QUALITY COMFORTRELIABILITY 3VERSION12 SIZE DESIGN VCEx0 vertical with cabinet Air intake: bottom vertical

More information

Integrated temperature test and calibration bench Model CBS-SC4000

Integrated temperature test and calibration bench Model CBS-SC4000 Calibration technology Integrated temperature test and calibration bench Model CBS-SC4000 WIKA data sheet CT 92.33 Applications Testing and calibration of temperature measuring instruments such as: - Mercury

More information

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Pilot Operated Pressure Relief Valve Series R5V (Denison) Characteristics Pilot operated pressure relief valves series R5V have a similar design to the subplate mounted R4V series. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps

More information

Mild Steel Dosing Pots

Mild Steel Dosing Pots Mild Steel Dosing Pots Data Sheet Features Introduction Materials of Construction Most heating and chilled water systems require chemical dosing and the BOSS range of Dosing Pots provides a controlled

More information

Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance

Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance MARINE DIESEL ENGINES D7.3L DI LD / D7.3L D-Tronic (Mercury MerCruiser D7.3L LD D-Tronic and D7.3L

More information

SKN_N0106AnnexJ_R2. Annex J - Specific requirements for PVT collector Certification. 1. Introduction and definition

SKN_N0106AnnexJ_R2. Annex J - Specific requirements for PVT collector Certification. 1. Introduction and definition Annex J - Specific requirements for PVT collector Certification 1. Introduction and definition PVT collectors (named hybrid collectors in ISO 9806) generate heat and electric power at the same time. They

More information

Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance

Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance MARINE DIESEL ENGINES D4.2L IDI (Mercury MerCruiser D4.2L Model) IMPORTANT: To comply with regulations

More information

Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance

Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance MARINE DIESEL ENGINES D4.2L 230 (4.2 MS 230 and 4.2 MI 230 Model) IMPORTANT: To comply with regulations

More information

5" SUBMERSIBLE PUMPS _ed.12/2014. Single member - Company subject to the control and coordination of Franklin Electric Co., Inc.

5 SUBMERSIBLE PUMPS _ed.12/2014. Single member - Company subject to the control and coordination of Franklin Electric Co., Inc. Vertical S.r.l. via Asolo, 7 36031 Dueville (Vicenza) - Italy Tel. +39 0444 361114 Fax +39 0444 365247 P.IVA e C.F. 00558130241 e-mail: sales@vertical.vi.it www.etechpumps.com Single member - Company subject

More information

5 x Solar Turbomach Taurus T60 (5.67MW ISO) Dual Fuel (Gas & HSD) Water Injection

5 x Solar Turbomach Taurus T60 (5.67MW ISO) Dual Fuel (Gas & HSD) Water Injection Bargh afshan alborz Amol Mazandaran Iran Tel: +98 (0)1212229599 Fax: +98 (0)1213239001 Email: ba_alborz@yahoo.com www.alborzgenerator.com 5 x Solar Turbomach Taurus T60 (5.67MW ISO) Dual Fuel (Gas & HSD)

More information

KS Pump Stations. Engineering Submittal Sheet. Installation Sets for Collectors

KS Pump Stations. Engineering Submittal Sheet. Installation Sets for Collectors Engineering Submittal Sheet Installation Sets for Collectors Layout legend S Supply from collector to storage R Return from storage to collector 1 Ball valve with thermometer and integrated gravity break

More information

Excel 10 (240 VAC, 1-phase, 60 Hz)

Excel 10 (240 VAC, 1-phase, 60 Hz) SWCC Summary Report Manufacturer: Wind Turbine Model: Certification Number: SWCC-10-12 Bergey Windpower Company Excel 10 (240 VAC, 1-phase, 60 Hz) The above-identified Small Wind Turbine is certified by

More information

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed

More information

TECHNICAL CATALOGUE AIR VENT VALVES AND SAFETY VALVES

TECHNICAL CATALOGUE AIR VENT VALVES AND SAFETY VALVES TECHNICAL CATALOGUE AIR VENT VALVES AND SAFETY VALVES TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and distribution

More information

Converters. IndraDrive C HCS02

Converters. IndraDrive C HCS02 IndraDrive C HCS02 2 Bosch Rexroth AG Electric Drives and Controls Continuous output from 1.5 kw to 11 kw Overload capacity 2.5x Maximum current from 12 A to 70 A Can be connected to inverters for cost-effective

More information

TECHNICAL CATALOGUE DISTRIBUTION MANIFOLDS

TECHNICAL CATALOGUE DISTRIBUTION MANIFOLDS TECHNICAL CATALOGUE DISTRIBUTION TEC ITAP SpA, founded in Lumezzane (Brescia) in 972, is currently one of the leading production companies in Italy of valves, fittings and distribution manifolds for plumbing

More information

Technical Product Submittal

Technical Product Submittal 1. General Specifications 1.01 Certifications 1) SRCC OG-100 Technical Product Submittal Oventrop evacuated tube solar thermal collector OVSOL 5-8, 8 tube collector and OVSOL 5-16, 16 tube collector SRCC

More information

Innovo Condensing high efficiency water heater

Innovo Condensing high efficiency water heater Condensing high efficiency water heater IR 12-160/20-160/12-200/20-200/24-245/32-245/ 24-285/32-285/32-380 A Fully room-sealed condensing high efficiency water heater Automatic gas/air premix burning system

More information

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF FORCE METROLOGY:- CALIBRATION OF UNIAXIAL TESTING MACHINES

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF FORCE METROLOGY:- CALIBRATION OF UNIAXIAL TESTING MACHINES CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF FORCE METROLOGY:- CALIBRATION OF UNIAXIAL TESTING MACHINES Approved By: Chief Executive Officer: Ron Josias Executive - Accreditation: Mpho Phaloane

More information

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB. Pre-assembled distribution manifolds for heating and air-conditioning systems 663 series FM 21654 003 065/18 GB replaces dp 065/06 GB Function The pre-assembled distribution manifolds are designed to optimise

More information

Fixed Displacement Bent Axis Axial Piston Pumps TPB 70 - TAP 70

Fixed Displacement Bent Axis Axial Piston Pumps TPB 70 - TAP 70 HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES Certified Company ISO 9001:2015-14001:2015 ISO 9001:2015 Certificate N 12-Q-0200545-TIC ISO 14001:2015 Certificate N 12-E-0200545-TIC

More information

NCC Leisure Battery Verification Scheme. Leisure Accommodation Vehicles

NCC Leisure Battery Verification Scheme. Leisure Accommodation Vehicles The UK trade body for the caravan, motorhome, caravan holiday and park home industry. NCC Leisure Battery Verification Scheme Leisure Accommodation Vehicles Page 1 of 11 1 Scope The NCC Battery Verification

More information

Converters IndraDrive C (800) HCS02 Mechanical Electrical Pneumatic Hydraulic Control Motion CMA/Flodyne/Hydradyne of Courtesy

Converters IndraDrive C (800) HCS02 Mechanical Electrical Pneumatic Hydraulic Control Motion CMA/Flodyne/Hydradyne of Courtesy IndraDrive C HCS02 2 Bosch Rexroth AG Electric Drives and Controls Continuous output from 1.5 kw to 11 kw Overload capacity 2.5x Maximum current from 12 A to 70 A Can be connected to inverters for cost-effective

More information

enviko solar product brochure

enviko solar product brochure enviko solar product brochure commercial & residential applications www.enviko.com Solar Thermal Evacuated Tube Collectors Top of the range, maximum efficiency solar evacuated tubes. Features These new

More information

Heat Exchangers & Enhanced Surface

Heat Exchangers & Enhanced Surface Tru-Twist Technology! Product Catalog Edition l A wor ld leader in enhanced heat transfer technology. Coaxial Heat Exchangers & Enhanced Surface Geothermal Renewable Energy Turbotec Products, Inc. Water

More information

Technical File Engine Model: MD706MX (4.2L 230) - MD706MS (4.2L 200)

Technical File Engine Model: MD706MX (4.2L 230) - MD706MS (4.2L 200) Engine Model: MD706MX (4.2L 230) - MD706MS (4.2L 200) Contents: 1 Components, settings and operating values of the engine which influence its NO x emissions Page 2 2 Full range of allowable adjustments

More information

Transformer bushings, type GOH. Technical guide

Transformer bushings, type GOH. Technical guide Transformer bushings, type GOH Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required

More information

PRODUCT RANGE A COMPLETE RANGE OF BURNERS FROM 17 TO kw

PRODUCT RANGE A COMPLETE RANGE OF BURNERS FROM 17 TO kw www.ecoflam-burners.com PRODUCT RANGE 2015 A COMPLETE RANGE OF BURNERS FROM 17 TO 34000 kw CUTTING-EDGE BURNERS FOR HEATING AND INDUSTRIAL APPLICATIONS Our proposal Ecoflam offers a full range of blown

More information

950x. Description. Part List

950x. Description. Part List Via Circonvallazione, 308 Valduggia (VC), Italy Tel: +39 063 4789 Fax: +39 063 47895 950x Variable Orifice Bronze Double Regulating Valve valvoindustria ing.rizzio s.p.a. Description Variable orifice bronze

More information

ISO INTERNATIONAL STANDARD. Earth-mover tyres and rims Part 3: Rims. Pneumatiques et jantes pour engins de terrassement Partie 3: Jantes

ISO INTERNATIONAL STANDARD. Earth-mover tyres and rims Part 3: Rims. Pneumatiques et jantes pour engins de terrassement Partie 3: Jantes INTERNATIONAL STANDARD ISO 4250-3 Fourth edition 2011-05-01 Earth-mover tyres and rims Part 3: Rims Pneumatiques et jantes pour engins de terrassement Partie 3: Jantes Reference number ISO 4250-3:2011(E)

More information

GH Hydro Kits. Technical Information. Ref: N

GH Hydro Kits. Technical Information. Ref: N GH Hydro Kits Ref: N-27167 0507 Technical Information Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT Certification Program. Products are as listed in the EUROVENT Directory

More information

Manufacturer: Address: ZIP Code: City: Country: VAT #: Signatory, Name: Signatory, Title: Phone: Fax: WWW: Head of Engineering:

Manufacturer: Address: ZIP Code: City: Country: VAT #: Signatory, Name: Signatory, Title: Phone: Fax:   WWW: Head of Engineering: CERTIFICATION APPLICATION Reciprocating internal combustion engines Certificate No.: EX Exhaust emission measurement - Part 1: Test-bed measurement of gaseous and particulate exhaust emissions Ref.: ISO

More information

GUIDE FOR CHOOSING AN ACCUMULATOR TANK

GUIDE FOR CHOOSING AN ACCUMULATOR TANK GUIDE FOR CHOOSING AN ACCUMULATOR TANK Preliminary version 0.1 13.3.2006 TABLE OF CONTENTS 1 OVERVIEW.. 5 2 OPERATING PRINCIPLE.. 6 3 DIMENSIONS. 8 4 PRODUCT RANGE. 10 5 SPATIAL REQUIREMENTS.. 12 6 TECHNICAL

More information

DVGW Prüflaboratorium Gas DBI Gastechnologisches Institut ggmbh FREIBERG

DVGW Prüflaboratorium Gas DBI Gastechnologisches Institut ggmbh FREIBERG Page: 2 of 10 Report No.: R e p o r t Contents: Page Test model 3 Applicable examinations 3 Explanations / characteristics 3 Countries / categories / inlet pressures 4 Technical data 5 Execution variants

More information

Flash Point Process Analyzer

Flash Point Process Analyzer Norms and standards ASTM D 56 ASTM D 93; DIN EN ISO 2719; IP 34 DIN EN ISO 13736; IP170 DIN 51755 Application The BARTEC BENKE Flash Point Process Analyzer (FPA-4) is a continuously measuring analyzer,

More information

Evacuated tube collectors

Evacuated tube collectors Evacuated tube collectors Evacuated tube collectors The overall performance of ecological heating systems based on solar thermal energy is significantly dependent on how efficiently the solar collector

More information

SOLAR AQUA. Operation and Installation Manual LDLINE AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP. Electronic Solar Control Center. for models CONTROLS INC.

SOLAR AQUA. Operation and Installation Manual LDLINE AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP. Electronic Solar Control Center. for models CONTROLS INC. AQUA SOLAR TM Electronic Solar Control Center Operation and Installation Manual for models AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP G LDLINE CONTROLS INC. www.goldlinecontrols.com 888-921-7665 IMPORTANT SAFETY

More information

Catch Eco Range : Technical Specification Sheet

Catch Eco Range : Technical Specification Sheet Catch Eco Range : Technical Specification Sheet Battery Hybrid Inverter AC Coupled Inverter Lithium phosphate technology High cycle life with warrantied throughput Indoor and outdoor options (IP21 and

More information

PRESSURIZED STEEL BOILER WITH REVERSED FLAME

PRESSURIZED STEEL BOILER WITH REVERSED FLAME smoke pipes PRESSURIZED STEEL BOILER WITH REVERSED FLAME OUTPUT RANGE from 340 to 7000 WORKING TEMPERATURE minimum return temperature 55 OPERATION WITH gas or oil fired jet burners MODELS 340 420 510 630

More information

AF 300 HYDRAULIC DRILL RIG

AF 300 HYDRAULIC DRILL RIG AF 300 HYDRAULIC DRILL RIG IMT International S.p.A. was founded in 1974 by Mr. Giulio Accorroni. Since then, the Company has concentrated on the acquisition of specific know-how for the planning and construction

More information

No. Date Items New Old Remarks. Regulations,EU certified Stage 3A Stage 2 from 2007~

No. Date Items New Old Remarks. Regulations,EU certified Stage 3A Stage 2 from 2007~ Revised record SPC-S3L-272(2/9) No. Date Items New Old Remarks Regulations,EU certified Stage 3A Stage 2 from 2007~ 1 Jun.30.2006 Specifications S3L2-Z263SP addition Spec.table 6/9pages addition 2 Oct.26.2006

More information

ISO INTERNATIONAL STANDARD. Wheelchairs Part 7: Measurement of seating and wheel dimensions

ISO INTERNATIONAL STANDARD. Wheelchairs Part 7: Measurement of seating and wheel dimensions INTERNATIONAL STANDARD ISO 7176-7 First edition 1998-05-15 Wheelchairs Part 7: Measurement of seating and wheel dimensions Fauteuils roulants Partie 7: Mesurage des dimensions d'assise et des roues A Reference

More information

MAZDON. Table of Contents. Cautions. MAZDON Collector Tube Figure 1 Figure 2

MAZDON. Table of Contents. Cautions. MAZDON Collector Tube Figure 1 Figure 2 Table of Contents MAZDON Cautions MAZDON Collector Tube Figure 1 Figure 2 Installation Procedure for MAZDON Sloping Roof (M) system Figure 3-6 Figure 7 Installation Procedure for MAZDON Sloping Roof (K)

More information

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management Ductable units NEW Eco-Design Filter Air handling unit with high available static pressure V3000 control Fresh air management The range of air handling units is designed for suspended ceiling heating and

More information

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration)

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration) CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration) Approved By: Chief Executive Officer: Ron Josias Executive - Accreditation: Mpho Phaloane Author:

More information

HELIUM SERIES COMPRESSOR SYSTEMS

HELIUM SERIES COMPRESSOR SYSTEMS HELIUM SERIES COMPRESSOR SYSTEMS Features a 1-year System and Block Warranty Jordair QC Program System Features: Block Features: ISO 9001:2008 Cert. 97-544 Balanced Design Low Oil Consumption CSA Cert.

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS The Caleffi Solar product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

SMALL PROTECTIVE VENT

SMALL PROTECTIVE VENT Accessories (Optional Parts) PMF-6B SMALL PROTECTIVE VENT Small and screw-in protective vent suitable for compact, and hand-held type devices. IP6 protection class (water depth meters / 60 mins) and -40

More information

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C) Simple, reliable efficient heat pump! Equipped with µconnect controller HFC R410A CERTITA CERTIFIED * Cooling capacity: 5 to 16.5 kw Heating capacity: 6 to 19 kw *except 75HT OPTION HEAT PUMP HEATING (30/35

More information

Date. Director c/o Petroleum Storage Program Manitoba Conservation and Water Stewardship 1007 Century Street Winnipeg, MB R3H 0W4

Date. Director c/o Petroleum Storage Program Manitoba Conservation and Water Stewardship 1007 Century Street Winnipeg, MB R3H 0W4 Date Director c/o Petroleum Storage Program Manitoba Conservation and Water Stewardship 1007 Century Street Winnipeg, MB R3H 0W4 To the Attention of the Director: Re: Insert Company Name Request for Variance

More information

CHANGE YOUR ENERGY CHARGE YOUR LIFE

CHANGE YOUR ENERGY CHARGE YOUR LIFE Innovation for a Better Life CHANGE YOUR ENERGY CHARGE YOUR LIFE Compact Size & Easy Installation Proven Safety The compact and lightweight nature of the RESU allows easier and faster installation both

More information

Collectors suitable for Industrial Applications

Collectors suitable for Industrial Applications Collectors suitable for Industrial Applications Werner Weiss AEE - Institute for Sustainable Technologies A-8200 Gleisdorf, Feldgasse 2 AUSTRIA Collector Overview Source: Elimar Frank - SPF What is a «Process

More information

Technical Manual. Positive displacement lobe pump. Serie C - CF. Translation of the original instructions

Technical Manual. Positive displacement lobe pump. Serie C - CF. Translation of the original instructions Technical Manual Positive displacement lobe pump Serie C - CF Translation of the original instructions all the power with a delicate touch T.M. C-CF Series rev.1 05/2012 All rights reserved O.M.A.C. S.R.L.

More information

VIESMANN. Product parameters Product range Datasheet

VIESMANN. Product parameters Product range Datasheet VIESMANN Product parameters Product range 2013 Datasheet Productspecific parameters for calculating the energy efficiency requirement in building regulations Part L1 and L2 11/2013 Product parameters Introduction:

More information

CALEFFI. Modulating temperature regulating unit with distribution kit for primary circuit. 171 series 01153/15 GB. replaces 01153/07 GB

CALEFFI. Modulating temperature regulating unit with distribution kit for primary circuit. 171 series 01153/15 GB. replaces 01153/07 GB ACCREDITED Modulating temperature regulating unit with distribution kit for primary circuit 7 series ISO 9 FM 6 / GB replaces /7 GB Function The temperature regulating unit with the distribution kit for

More information

AQUA SOLAR. Operation and Installation Manual AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP. Electronic Solar Control Center. for models CON TROLS

AQUA SOLAR. Operation and Installation Manual AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP. Electronic Solar Control Center. for models CON TROLS AQUA SOLAR TM Electronic Solar Control Center Operation and Installation Manual for models AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP G LDLINE CON TROLS www.goldlinecontrols.com IMPORTANT SAFETY INSTRUCTIONS

More information

PHP-C Pressureless Expansion System Overview Description: The PHP-C balanced pressure expansion equipment is sized according to the total system volume and the boiler or chiller load. The PHP-C vessel

More information

MINI EXCAVATORS. Concrete solutions. Always ES 10 ZT. Operating weight kg Engine power 7,6 kw - 10,0 HP

MINI EXCAVATORS. Concrete solutions. Always ES 10 ZT. Operating weight kg Engine power 7,6 kw - 10,0 HP MINI EXCAVATORS Concrete solutions. Always Operating weight 1.060 kg Engine power 7,6 kw - 10,0 HP 1 Its extremely compact size allow it to pass through narrow spots and to be used in tight spaces where

More information

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07. Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water

More information

GASOKOL vacutube. GASOKOL GmbH, vacutube_de 1 von 5

GASOKOL vacutube. GASOKOL GmbH, vacutube_de 1 von 5 Principle: Because of the warming up the fluid into the absorber pipe converts into steam, the vacuum into the circuit supports this process. The steam rises by its own incentive. The fluid liquefies into

More information

DVGW Prüflaboratorium Gas DBI Gastechnologisches Institut ggmbh FREIBERG

DVGW Prüflaboratorium Gas DBI Gastechnologisches Institut ggmbh FREIBERG Page: 2 of 10 Report No. R e p o r t Contents: Page Test model 3 Applicable examinations 3 Explanations / characteristics 3 Countries / categories / inlet pressures 4 Technical data 5 Execution variants

More information

Art.918C Pre-assembled manifold with flow meters, air

Art.918C Pre-assembled manifold with flow meters, air TECHNICAL CATALOGUE Art.98C Pre-assembled manifold with flow meters, air vent valves and drain cock TEC ITAP SpA, founded in Lumezzane (Brescia) in 97, is currently one of the leading production companies

More information

SWCC Summary Report. Eveready Diversified Products (Pty) Ltd T/A Kestrel Renewable Energy. Certification Number: SWCC (240 VAC, 1-phase, 60 Hz)

SWCC Summary Report. Eveready Diversified Products (Pty) Ltd T/A Kestrel Renewable Energy. Certification Number: SWCC (240 VAC, 1-phase, 60 Hz) SWCC Summary Report Manufacturer: Wind Turbine Model: Eveready Diversified Products (Pty) Ltd T/A Kestrel Renewable Energy Kestrel e400nb (240 VAC, 1-phase, 60 Hz) Certification Number: SWCC-10-16 The

More information

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces MODEL: TCF Cased/Uncased Coils For Gas And Oil Furnaces FORM NO. CSC-224 REV. 1 Sure Comfort TCF Cased/Uncased Coils For Gas And Oil Furnaces (TXV Metering Device Shown) Featuring Industry Standard R-410A

More information

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCF- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] (TXV Metering Device Shown) Ruud Indoor

More information

CH 450. High Tech Line. Self-Erecting Hydraulic Piling Rig

CH 450. High Tech Line. Self-Erecting Hydraulic Piling Rig CH 450 High Tech Line Self-Erecting Hydraulic Piling Rig CH 450 MULTIPURPOSE HYDRAULIC RIGS FOR DIFFERENT DRILLING TECHNOLOGIES. The winning solution for job sites that require fast operating times. Truly

More information

Fluid Monitoring Station

Fluid Monitoring Station Fluid Monitoring Station Executive Summary The Option Industries Fluid Monitoring Station (FMS) is a portable unit which monitors and records fluid rates and total volumes of water pulled from location.

More information

ISO 9129 INTERNATIONAL STANDARD. Motorcycles Measurement methods for moments of inertia. Motocycles Méthodes de mesure des moments d'inertie

ISO 9129 INTERNATIONAL STANDARD. Motorcycles Measurement methods for moments of inertia. Motocycles Méthodes de mesure des moments d'inertie INTERNATIONAL STANDARD ISO 9129 Second edition 2008-05-15 Motorcycles Measurement methods for moments of inertia Motocycles Méthodes de mesure des moments d'inertie Reference number ISO 2008 PDF disclaimer

More information

DUO-TEC COMPACT SPARE PARTS CATALOGUE

DUO-TEC COMPACT SPARE PARTS CATALOGUE DUO-TEC COMPACT SPARE PARTS CATALOGUE - Aprile 2016 - HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this

More information

RAMIRENT E19. Excavators Specifications. Dimensions

RAMIRENT E19. Excavators Specifications. Dimensions Dimensions (A) Blade height 235.0 mm (B) Clearance, upper structure to ground line 419.0 mm (C) Ground line to top of engine cover 1340.0 mm (D) Length of track on ground 1114.0 mm (E) Machine centre line

More information

VRF. Technical Data Book. Duct S for Europe (R410, 50Hz)

VRF. Technical Data Book. Duct S for Europe (R410, 50Hz) VRF Technical Data Book Duct S for Europe (R410, 50Hz) Version Modification Date Remark Ver.1.0 Release VRF DVM S IDU Duct S for Europe (R410A, 50Hz) TDB 14.09.22 Ver.1.1 External Pressure Minimum data

More information

Hawaii Energy PY2015 PV WH. Standards & Specifications

Hawaii Energy PY2015 PV WH. Standards & Specifications Hawaii Energy PY2015 PV WH 1.1. PV WH SYSTEMS Solar systems installed under the Hawaii Energy Solar Water Heating Program ( the Program ) shall conform to applicable local building, plumbing and electrical

More information

CALEFFI. Direct supply unit for heating systems. 165 series 01237/17 GB. replaces dp 01237/15 GB. Function

CALEFFI. Direct supply unit for heating systems. 165 series 01237/17 GB. replaces dp 01237/15 GB. Function Direct supply unit for heating systems 65 series ACCREDITED ISO 9 FM 65 CALEFFI 7/7 GB replaces dp 7/5 GB Function The direct supply unit performs the function of supplying the heating system circuits

More information

Fan coil units MAJOR 2 CV/CH

Fan coil units MAJOR 2 CV/CH CH 41 D CV 1 D MAJOR 2: Design and performance HEE impeller for increased performance Motor optional MAJOR 2 is a non-independant chilled and/or hot water supplied air conditioning Comfort unit for the

More information

HORIZONTAL MULTISTAGE PUMPS

HORIZONTAL MULTISTAGE PUMPS ORIZONTA MUTISTAGE PUMPS INDEX E Stainless Steel orizontal Multistage Pump.... 2 General Product Curves.... 3 Material Table... 3 Table of hydraulic performances at - E 3-5 - 9...........................................................

More information

6/2 ways/positions flow diverters

6/2 ways/positions flow diverters 6/2 ways/positions flow diverters RE 18302-07/07.12 Replaces: 12.09 1/8 L753... (VS311-VS312-VS315) Size 10 Series 00 Maximum operating pressure 310 bar [4500 psi] Maximum flow 140 l/min [36,98 gpm] Ports

More information