DIN CERTCO Alboinstraße Berlin Tel: Fax:
|
|
- Myles Abner Pierce
- 5 years ago
- Views:
Transcription
1 Area (AG) length width Total nominal volume height width depth Auxiliary heated volume Electrical aux. heating power Page 1 of 7 Summary of EN SOLAR SYSTEM test results Annex to Solar KEYMARK Certificate Brand (optional) Ariston Thermo S.p.A. ARISTON KAIROS Street Via A. Merloni 45 Postal Code Fabriano System classification Application(s) Hot water Solar loop, circulation principle Thermosyphon Direct solar loop / heat exchanger Direct Open, vented or closed solar loop Closed Drain back/down Always filled (no drain) Store location Outdoor Store orientation (of main axis) Horizontal Type of auxiliary heating (internal backup heat) Electric If other auxiliary/internal backup heating, please specifiy: Solar+supplementary OR Solaronly / Solar preheat Solar only / Solar preheat Collector(s) Ariston Thermo S.p.A Keymark lic.no. if available 0117S2613 F Per module Licence Number Issued Country Tel. / Fax +39 Heat store(s) Ariston Thermo S.p.A Keymark lic.no. if available 0117S2612 A Italy public.relations@aristonthermo.com / 40 Store name m² mm mm CNA 200 THERMO DR CNA 200 THERMO DRE CNA 300 THERMO DR CNA 300 THERMO DRE litres mm mm mm litres kw Solar loop controller Keymark lic.no. if available Name Solar loop pump power range W to W Solar loop fluid Recommended/required Required Name water Freezing point C Number of collectors in each configuration for each store Store name CNA 200 THERMO DR NA 200 THERMO DRE 2KWCNA 300 THERMO DR NA 300 THERMO DRE 2KW 2 2 Test report id. number Date of test report ; ; Because of reaching the limited faux value according to ISO 94595, a long term Version 3.6, Tel: Fax: info@dincertco.de
2 Page 2 of 7 Summary of EN test results Certification No. 0117S2612 A Annex to Solar KEYMARK Certificate Issued Ariston Thermo S.p.A. Country Italy Brand (optional) ARISTON KAIROS Street Via A. Merloni 45 public.relations@aristonthermo.com Postal Code Fabriano Tel. / Fax / 40 CNA 200 THERMO DR NA 200 THERMO DRE 2KWCNA 300 THERMO DR NA 300 THERMO DRE 2KW 2 2 ARISTON KAIROS THERMO DR 2001 No. Collectors 1 Storage name CNA 200 THERMO DR Calculated annual results for "solaronly / preheat system" Stockholm SE WürzburgDE Davos CH Athens GR MJ/y Not relevant for solar domestic hot water system f sol =Q L /Q d Solar fraction G Ref. conditions Ta,ave Max. operating press. collector side 700 kpa Max. operating press. tank side 700 Test report id. number Date of test report No comments ; ; ISO (DST) kpa All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 15 % Version 3.6, Tel: Fax: info@dincertco.de
3 Page 3 of 7 Summary of EN test results Certification No. 0117S2612 A Annex to Solar KEYMARK Certificate Issued Ariston Thermo S.p.A. Country Italy Brand (optional) ARISTON KAIROS Street Via A. Merloni 45 public.relations@aristonthermo.com Postal Code Fabriano Tel. / Fax / 40 CNA 200 THERMO DR NA 200 THERMO DRE 2KWCNA 300 THERMO DR NA 300 THERMO DRE 2KW 2 2 ARISTON KAIROS THERMO DRE 2KW 2001 No. Collectors 1 Storage name CNA 200 THERMO DRE 2KW Calculated annual results for "solaronly / preheat system" Stockholm SE WürzburgDE Davos CH Athens GR MJ/y Not relevant for solar domestic hot water system f sol =Q L /Q d Solar fraction G Max. operating press. collector side 700 kpa Max. operating press. tank side 700 kpa Date of test report ; ISO (DST) Because of reaching the limited faux value according to ISO 94595, a long term All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 15 % Version 3.6, Tel: Fax: info@dincertco.de
4 Page 4 of 7 Summary of EN test results Certification No. 0117S2612 A Annex to Solar KEYMARK Certificate Issued Ariston Thermo S.p.A. Country Italy Brand (optional) ARISTON KAIROS Street Via A. Merloni 45 public.relations@aristonthermo.com Postal Code Fabriano Tel. / Fax / 40 CNA 200 THERMO DR NA 200 THERMO DRE 2KWCNA 300 THERMO DR NA 300 THERMO DRE 2KW 2 2 ARISTON KAIROS THERMO DR 3001 No. Collectors 2 Storage name CNA 300 THERMO DR Calculated annual results for "solaronly / preheat system" Daily drawoff 250 l Daily drawoff 300 l Daily drawoff 400 l Stockholm SE WürzburgDE Davos CH Athens GR MJ/y Not relevant for solar domestic hot water system f sol =Q L /Q d Solar fraction G Max. operating press. collector side 700 kpa Max. operating press. tank side 700 kpa Date of test report ; ISO (DST) No comments All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 15 % Version 3.6, Tel: Fax: info@dincertco.de
5 Page 5 of 7 Summary of EN test results Certification No. 0117S2612 A Annex to Solar KEYMARK Certificate Issued Ariston Thermo S.p.A. Country Italy Brand (optional) ARISTON KAIROS Street Via A. Merloni 45 public.relations@aristonthermo.com Postal Code Fabriano Tel. / Fax / 40 CNA 200 THERMO DR NA 200 THERMO DRE 2KWCNA 300 THERMO DR NA 300 THERMO DRE 2KW 2 2 ARISTON KAIROS THERMO DRE 2KW 3001 No. Collectors 2 Storage name CNA 300 THERMO DRE 2KW Calculated annual results for "solaronly / preheat system" Daily drawoff 250 l Daily drawoff 300 l Daily drawoff 400 l Stockholm SE WürzburgDE Davos CH Athens GR MJ/y Not relevant for solar domestic hot water system f sol =Q L /Q d Solar fraction G Max. operating press. collector side 700 kpa Max. operating press. tank side 700 kpa Date of test report ; ISO (DST) Because of reaching the limited faux value according to ISO 94595, a long term All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 15 % Version 3.6, Tel: Fax: info@dincertco.de
6 Page 6 of 7 Summary of EN test results Certification No. 0117S2612 A Annex to Solar KEYMARK Certificate Issued Ariston Thermo S.p.A. Country Italy Brand (optional) ARISTON KAIROS Street Via A. Merloni 45 public.relations@aristonthermo.com Postal Code Fabriano Tel. / Fax / 40 CNA 200 THERMO DR NA 200 THERMO DRE 2KWCNA 300 THERMO DR NA 300 THERMO DRE 2KW 2 2 ARISTON KAIROS THERMO DR 2001 HR No. Collectors 1 Storage name CNA 200 THERMO DR Calculated annual results for "solaronly / preheat system" Stockholm SE WürzburgDE Davos CH Athens GR MJ/y Not relevant for solar domestic hot water system f sol =Q L /Q d Solar fraction G Max. operating press. collector side 700 kpa Max. operating press. tank side 700 kpa Date of test report ; ISO (DST) No comments All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 15 % Version 3.6, Tel: Fax: info@dincertco.de
7 Page 7 of 7 Summary of EN test results Certification No. 0117S2612 A Annex to Solar KEYMARK Certificate Issued Ariston Thermo S.p.A. Country Italy Brand (optional) ARISTON KAIROS Street Via A. Merloni 45 public.relations@aristonthermo.com Postal Code Fabriano Tel. / Fax / 40 CNA 200 THERMO DR NA 200 THERMO DRE 2KWCNA 300 THERMO DR NA 300 THERMO DRE 2KW 2 2 ARISTON KAIROS THERMO DRE 2KW 2001 HR No. Collectors 1 Storage name CNA 200 THERMO DRE 2KW Calculated annual results for "solaronly / preheat system" Stockholm SE WürzburgDE Davos CH Athens GR MJ/y Not relevant for solar domestic hot water system f sol =Q L /Q d Solar fraction G Max. operating press. collector side 700 kpa Max. operating press. tank side 700 kpa Date of test report ; ISO (DST) Because of reaching the limited faux value according to ISO 94595, a long term All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 15 % Version 3.6, Tel: Fax: info@dincertco.de
DIN CERTCO Alboinstraße Berlin Tel: Fax:
Area (AG) length width Total nominal volume height width depth Auxiliary heated volume Electrical aux. heating power Page 1 of 8 Summary of EN129762 SOLAR SYSTEM test results Annex to Solar KEYMARK Certificate
More informationAriston Thermo S.p.A Keymark lic.no. if available - Company. Store name. length. width. Gross CNA150HF CNA200HF CNA300HF. Company. Name.
Page 1 of 8 Summary of EN12976-2 SOLAR SYSTEM test results Annex to Solar KEYMARK Certificate Brand (optional) Ariston Thermo S.p.A. ARISTON KAIROS Street Via A. Merloni 45 Postal Code 60044 Fabriano Licence
More informationDIN CERTCO Alboinstraße Berlin Tel: Fax:
1 of Page Suary of EN12976-2 SOLAR SYSTEM test results Annex to Solar KEYMARK Certificate Licence Number Issued Brand (optional) Street Postal Code Country E-mail Tel. / Fax 17, Rue de la petite Baratte
More informationAnnex to Solar KEYMARK Certificate
Page 1 of 7 Summary of EN12976-2 SOLAR SYSTEM test results Annex to Solar KEYMARK Certificate Brand (optional) SAMMLER B. Michalopoulos sa Street 18 Chiou str. Aspropyrgos Ind. Zone Postal Code GR-19300
More informationCERTIFICATE. Solar Keymark Certificate No. SP SC
CERTIFICATE Solar Keymark Certificate No. SP SC0895-2 Holder/Issued to/manufacturer : Jiangsu Micoe Solar Energy Co. Ltd Address: NingHai Industrial Zone, Lianyungang City, Jiangsu Province, China Product
More informationAnnex to Solar KEYMARK Certificate
Page 1 of 7 Summary of EN12976-2 SOLAR SYSTEM test results Annex to Solar KEYMARK Certificate Brand (optional) Cirelius, Lda. Street Rua Inocencio Osorio L. Gondim, 103; ZI Avintes Postal Code PT-4430-662
More informationSummary of EN Test Results, Licence Number 011-7S471 R annex to Solar KEYMARK Certificate Issued
Summary of EN 12975 Test Results, Licence Number 011-7S471 R annex to Solar KEYMARK Certificate Issued 2014-08-28 Company holding the Brand (optional) Ako Tec Produktionsgesellschaft mbh Ako Tec Country
More informationSummary of EN Test Results, Licence Number 011-7S660 R annex to Solar KEYMARK Certificate Issued
Summary of EN 12975 Test Results, Licence Number 011-7S660 R annex to Solar KEYMARK Certificate Issued 2014-08-28 Company holding the Brand (optional) Ako Tec Produktionsgesellschaft mbh Ako Tec Country
More informationResults of annual simulation
2 x Vitosol 100-FM SVKF Total gross surface area:4,46 m² Azimuth: 0 Incl.: 30 160 Liters/Day 50 C Gas-fired boiler 26 kw Vitocell 100-B Vol : 250 l Results of annual simulation Installed collector power:
More informationNombre de modules. Number of modules. Kollektoranzahl. Bezeichnung. Modèle. Model. m² m m min - max litres mm mm litres
Summary EN 297 Test Results, Kurzfassung EN 297 Test Ergebnisse, Anlage zum Solar KEYMARK-Zertifikat Synthèse s résultas d'essais selon EN 297, Annexe au certificat Solar Register-Nr. s Zertifikat Numéro
More informationExample printout. Building project. SDC Example. Dyfi Eco Park SY20 8AX Machynlleth UK. Mr C. Laughton Phone:
Building project SDC Example Dyfi Eco Park SY20 8AX Machynlleth UK Contact person: Mr C. Laughton Phone: 01654 700324 E-Mail: software@solardesign.co.uk Results of annual simulation Installed collector
More informationINSTALLATION MANUAL OF EZINC OPEN LOOP THERMO SIPHON SOLAR WATER HEATING SYSTEMS
INSTALLATION MANUAL OF EZINC OPEN LOOP THERMO SIPHON SOLAR WATER HEATING SYSTEMS 1) INTRODUCTION 2) GENERAL FEATURES 3) OPERATION INSTRUCTIONS 4) SUPPORT BASE AND MOUNTING STEPS 5) FITTINGS & CONNECTIONS
More informationCOMPONENTS FOR SOLAR THERMAL SYSTEMS
COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending
More informationCALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB
Distribution manifold for radiant panel systems 664 series ACCREDITED CALEFFI 01260/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The distribution manifold for radiant panel systems is used to optimally
More informationSpecification Manual Ground Source Heat Pumps Northern Geo LLC 75 West Veum Appleton, MN
Specification Manual Ground Source Heat s www.northernheatpump.com Northern Geo LLC 75 West Veum Appleton, MN 56208 320-297-9100 info@northerngeo.com 07/30/2015 NL003 NorthStar Series Features & Benefits
More informationCALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/18 GB. replaces 01260/14 GB
Distribution manifold for radiant panel systems 664 series FM 21654 003 CALEFFI 01260/18 GB replaces 01260/14 GB Function The distribution manifold for radiant panel systems is used to optimally distribute
More informationDS Series Solar System
DS Series Solar System Permit information Consol 30-58-1800 Collector Flat mount on Colorsteel Plumdeck roofing Valve vent, Open loop http:// www.consolsolar.co.nz 21 Page 1 of This system is an evacuated
More informationDVGW Prüflaboratorium Gas DBI Gastechnologisches Institut ggmbh FREIBERG
Page: 2 of 10 Report No. R e p o r t Contents: Page Test model 3 Applicable examinations 3 Explanations / characteristics 3 Countries / categories / inlet pressures 4 Technical data 5 Execution variants
More informationTechnical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance
Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance MARINE DIESEL ENGINES D7.3L DI LD / D7.3L D-Tronic (Mercury MerCruiser D7.3L LD D-Tronic and D7.3L
More informationPilot Operated Pressure Relief Valve Series R5V (Denison)
Characteristics Pilot operated pressure relief valves series R5V have a similar design to the subplate mounted R4V series. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps
More informationTechnical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance
Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance MARINE DIESEL ENGINES D4.2L IDI (Mercury MerCruiser D4.2L Model) IMPORTANT: To comply with regulations
More informationTechnical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance
Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance MARINE DIESEL ENGINES D4.2L 230 (4.2 MS 230 and 4.2 MI 230 Model) IMPORTANT: To comply with regulations
More informationSDHW System Inspection Form
SDHW System Inspection Form Project/Homeowner Name: Project #: Date: Contractor: Inspector: In Attendance: Approx Install Date: Type of System Closed Loop Drain Back Drain Down Thermosyphon Other Type
More informationIntegrated temperature test and calibration bench Model CBS-SC4000
Calibration technology Integrated temperature test and calibration bench Model CBS-SC4000 WIKA data sheet CT 92.33 Applications Testing and calibration of temperature measuring instruments such as: - Mercury
More informationCALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB.
Composite manifolds specifically designed for radiant panel systems 670 series FM 165 00 CALEFFI 0116/18 GB replaces dp 0116/11 GB Function Composite manifolds are used to control and distribute the medium
More informationManufacturer: Address: ZIP Code: City: Country: VAT #: Signatory, Name: Signatory, Title: Phone: Fax: WWW: Head of Engineering:
CERTIFICATION APPLICATION Reciprocating internal combustion engines Certificate No.: EX Exhaust emission measurement - Part 1: Test-bed measurement of gaseous and particulate exhaust emissions Ref.: ISO
More informationTechnical File Engine Model: MD706MX (4.2L 230) - MD706MS (4.2L 200)
Engine Model: MD706MX (4.2L 230) - MD706MS (4.2L 200) Contents: 1 Components, settings and operating values of the engine which influence its NO x emissions Page 2 2 Full range of allowable adjustments
More informationsomething new in the air Technical Bulletin
something new in the air Technical Bulletin 2 Air Leaf 2 Air Leaf 3 Innova is a company operating in the renewable energy sector and develops advanced climatic comfort systems for every season. The technological
More informationDVGW Prüflaboratorium Gas DBI Gastechnologisches Institut ggmbh FREIBERG
Page: 2 of 10 Report No.: R e p o r t Contents: Page Test model 3 Applicable examinations 3 Explanations / characteristics 3 Countries / categories / inlet pressures 4 Technical data 5 Execution variants
More informationConverters. IndraDrive C HCS02
IndraDrive C HCS02 2 Bosch Rexroth AG Electric Drives and Controls Continuous output from 1.5 kw to 11 kw Overload capacity 2.5x Maximum current from 12 A to 70 A Can be connected to inverters for cost-effective
More informationSKN_N0106AnnexJ_R2. Annex J - Specific requirements for PVT collector Certification. 1. Introduction and definition
Annex J - Specific requirements for PVT collector Certification 1. Introduction and definition PVT collectors (named hybrid collectors in ISO 9806) generate heat and electric power at the same time. They
More informationConverters IndraDrive C (800) HCS02 Mechanical Electrical Pneumatic Hydraulic Control Motion CMA/Flodyne/Hydradyne of Courtesy
IndraDrive C HCS02 2 Bosch Rexroth AG Electric Drives and Controls Continuous output from 1.5 kw to 11 kw Overload capacity 2.5x Maximum current from 12 A to 70 A Can be connected to inverters for cost-effective
More informationSpecification Manual
Specification Manual Ground Source Heat s www.northernheatpump.com Northern Geo LLC 75 West Veum Appleton, MN 56208 320-297-9100 info@northerngeo.com 09/03/2014 NL003 NorthStar Series Features & Benefits
More informationCompact hydraulic power unit Type BKA
Compact hydraulic power unit Type BKA Single- and two-stage up to 700 bar Features Compact design Self-venting Various combinations possible Single- or two-stage models Design Integrated low-pressure unloading
More informationenviko solar product brochure
enviko solar product brochure commercial & residential applications www.enviko.com Solar Thermal Evacuated Tube Collectors Top of the range, maximum efficiency solar evacuated tubes. Features These new
More informationVIESMANN. Product parameters Product range Datasheet
VIESMANN Product parameters Product range 2013 Datasheet Productspecific parameters for calculating the energy efficiency requirement in building regulations Part L1 and L2 11/2013 Product parameters Introduction:
More informationCRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF FORCE METROLOGY:- CALIBRATION OF UNIAXIAL TESTING MACHINES
CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF FORCE METROLOGY:- CALIBRATION OF UNIAXIAL TESTING MACHINES Approved By: Chief Executive Officer: Ron Josias Executive - Accreditation: Mpho Phaloane
More informationCENTRIFUGAL FAN COIL UNIT VCE
CENTRIFUGAL FAN COIL UNIT VCE 0,51 kw 11,00 kw 0,85 kw 23,75 kw 129 m 3 /h 2003 m 3 /h VCE DESIGN QUALITY COMFORTRELIABILITY 3VERSION12 SIZE DESIGN VCEx0 vertical with cabinet Air intake: bottom vertical
More informationW O R K B O AT R A N G E
WORKBOAT RANGE Engine Range Workboat Engine Range February 2014 Engine Model 20WB 30WB 40WB 50WB 70WB 85WB 130WB Cylinders 3 3 4 4 4 4 6 Horsepower 20 30 40 50 70 85 130 RPM 2800 3000 2600 3000 2500 2500
More informationGENERAL SPECIFICATIONS AND PRODUCT DESCRIPTION
AIR CONDITIONING GENERAL SPECIFICATIONS AND PRODUCT DESCRIPTION Effective 1 February 2013 PRODUCT DESCRIPTION - ALL MODELS FAN Direct drive, high efficiency, low noise. All polymer with taper lock quick
More informationCALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.
Pre-assembled distribution manifolds for heating and air-conditioning systems 663 series FM 21654 003 065/18 GB replaces dp 065/06 GB Function The pre-assembled distribution manifolds are designed to optimise
More informationGUIDE FOR CHOOSING AN ACCUMULATOR TANK
GUIDE FOR CHOOSING AN ACCUMULATOR TANK Preliminary version 0.1 13.3.2006 TABLE OF CONTENTS 1 OVERVIEW.. 5 2 OPERATING PRINCIPLE.. 6 3 DIMENSIONS. 8 4 PRODUCT RANGE. 10 5 SPATIAL REQUIREMENTS.. 12 6 TECHNICAL
More informationThe PV Markets and Industrial Activity In Greece and Bulgaria. Dr. Alexander Zachariou Energy Solutions & Solar Cells Hellas
The PV Markets and Industrial Activity In Greece and Bulgaria Dr. Alexander Zachariou Energy Solutions & Solar Cells Hellas Thessaloniki, 21-22 May 2008 Introduction Climate conditions in SE Europe are
More informationMild Steel Dosing Pots
Mild Steel Dosing Pots Data Sheet Features Introduction Materials of Construction Most heating and chilled water systems require chemical dosing and the BOSS range of Dosing Pots provides a controlled
More informationRAFFAELLO SPARE PARTS CATALOGUE
RAFFAELLO SPARE PARTS CATALOGUE SUMMARY PAGE 1 PAGE 2 PAGE 3 PAGE 4 PAGE 5 PAGE 6 PAGE 7 PAGE 8 PAGE 9 PAGE 10 PAGE 11 PAGE 12 PAGE 13 GROUP GROUP BODY WORK BODY WORK BODY WORK Valve block PUMP Hot water
More informationSingle-axis inverter IndraDrive M - HMS
Single-axis inverter IndraDrive M - HMS 2 Bosch Rexroth AG Electric Drives and Controls Technical data Documentation Operating instructions Project planning manual W0020 W0036 W0054 W0070 W0110 Performance
More informationExcel 10 (240 VAC, 1-phase, 60 Hz)
SWCC Summary Report Manufacturer: Wind Turbine Model: Certification Number: SWCC-10-12 Bergey Windpower Company Excel 10 (240 VAC, 1-phase, 60 Hz) The above-identified Small Wind Turbine is certified by
More informationCOMPONENTS FOR SOLAR THERMAL SYSTEMS
COMPONENTS FOR SOLAR THERMAL SYSTEMS The Caleffi Solar product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending
More informationInstallation Instructions. Vitosol 100. Vitosol 100 Type w 2.5 Flat collector for flat roofs and freestanding installation Part No.
Installation Instructions Vitosol 100 Type w 2.5 Flat collector for flat roofs and freestanding installation Part No. 3001 970 Vitosol 100 8/99 Safety instructions This hazard symbol precedes all important
More informationP U M P S OUR WORLD IS FULL OF ENERGY TS SERIES
P U M P S OUR WORLD IS FULL OF ENERGY SOLAR SUBMERSIBLE PUMPS - TS SERIES I N D E X SOLAR SUBMERSIBLE PUMPS - TS SERIES Introduction, Applications & Features 3 Model Classification & Model Designation
More informationTECHNICAL CATALOGUE AIR VENT VALVES AND SAFETY VALVES
TECHNICAL CATALOGUE AIR VENT VALVES AND SAFETY VALVES TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and distribution
More informationCRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration)
CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration) Approved By: Chief Executive Officer: Ron Josias Executive - Accreditation: Mpho Phaloane Author:
More information5 x Solar Turbomach Taurus T60 (5.67MW ISO) Dual Fuel (Gas & HSD) Water Injection
Bargh afshan alborz Amol Mazandaran Iran Tel: +98 (0)1212229599 Fax: +98 (0)1213239001 Email: ba_alborz@yahoo.com www.alborzgenerator.com 5 x Solar Turbomach Taurus T60 (5.67MW ISO) Dual Fuel (Gas & HSD)
More informationISO INTERNATIONAL STANDARD. Wheelchairs Part 7: Measurement of seating and wheel dimensions
INTERNATIONAL STANDARD ISO 7176-7 First edition 1998-05-15 Wheelchairs Part 7: Measurement of seating and wheel dimensions Fauteuils roulants Partie 7: Mesurage des dimensions d'assise et des roues A Reference
More informationHYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment
Screw compressors CIAT shell and tubes direct expansion evaporator (High Power System) equipment Cooling capacity: 370 to 1 170 kw Heating capacity: 500 to 1 400 kw Heating Cooling Heat recovery Use The
More informationInstallation instruction
1 Safety Before installing the device, please read this manual carefully. Please note that the installation must be executed according to relevant technical rules. The installation must also be adapted
More informationTECHNICAL CATALOGUE DISTRIBUTION MANIFOLDS
TECHNICAL CATALOGUE DISTRIBUTION TEC ITAP SpA, founded in Lumezzane (Brescia) in 972, is currently one of the leading production companies in Italy of valves, fittings and distribution manifolds for plumbing
More informationDate. Director c/o Petroleum Storage Program Manitoba Conservation and Water Stewardship 1007 Century Street Winnipeg, MB R3H 0W4
Date Director c/o Petroleum Storage Program Manitoba Conservation and Water Stewardship 1007 Century Street Winnipeg, MB R3H 0W4 To the Attention of the Director: Re: Insert Company Name Request for Variance
More informationKS Pump Stations. Engineering Submittal Sheet. Installation Sets for Collectors
Engineering Submittal Sheet Installation Sets for Collectors Layout legend S Supply from collector to storage R Return from storage to collector 1 Ball valve with thermometer and integrated gravity break
More informationDesign Criteria Data
MIDLAND TX Latitude = 31.95 N WMO No. 72265 Longitude =2. W Elevation = 2861 feet Period of Record = 1973 to 1996 Average Pressure = 27.3 inches Hg Design Criteria Data Mean Coincident (Average) Values
More informationMAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional
Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed
More informationDesign Criteria Data
ALBUQUERQUE NM Latitude = 35.5 N WMO No. 72365 Longitude =16.6 W Elevation = 5315 feet Period of Record = 1967 to 1996 Average Pressure = 24.72 inches Hg Design Criteria Data Mean Coincident (Average)
More information6/2 ways/positions flow diverters
6/2 ways/positions flow diverters RE 18302-07/07.12 Replaces: 12.09 1/8 L753... (VS311-VS312-VS315) Size 10 Series 00 Maximum operating pressure 310 bar [4500 psi] Maximum flow 140 l/min [36,98 gpm] Ports
More informationPOINT OBSTRUCTION LIGHTS SOL LED SOLAR POWERED OBSTRUCTION SYSTEM
SOLAR POWERED OBSTRUCTION SYSTEM Compliances: ETL Listed to UL 1598 Wet Locations ETL Listed to CSA C22.2 No.250.0-04 Canada FAA Approved L-810 & L-864 by Advisory Circular 150/5345-43H Verified to ICAO
More informationMP-100-APS. Flame Spray Technologies SprayTech. Multi-Process Thermal Spray Centre
bv Impact 4, 6921 RZ Duiven P.O. Box 1027, 6920 BA Duiven The Netherlands Tel: +31 263190140 Fax: +31 263190141 E-mail: info@fst.nl Homepage: www.fst.nl Inc. 3040 Charlevoix Dr. SE Suite 203 I Grand Rapids,
More informationOIL BURNERS. MINOR 1 Snorkel 240 Volt 50 Hz
OIL BURNERS MINOR 1 Snorkel 240 Volt 50 Hz 420010675700 04.06.2015 TECHNICAL DATA MODEL MINOR 1 SNORKEL Thermal power max kcal/h 25500 kw 29,6 Thermal power min kcal/h 17300 kw 20 Max capacity light oil
More informationMAZDON. Table of Contents. Cautions. MAZDON Collector Tube Figure 1 Figure 2
Table of Contents MAZDON Cautions MAZDON Collector Tube Figure 1 Figure 2 Installation Procedure for MAZDON Sloping Roof (M) system Figure 3-6 Figure 7 Installation Procedure for MAZDON Sloping Roof (K)
More informationTechnical Information
Subject Application of "Approved Method" to existing diesel engines under the provisions of Revised MARPOL ANNEX VI - Certification of an Approved Method for WÄRTSILÄ RTA engines - To whom it may concern
More informationUNITED STATES ENVIRONMENTAL PROTECTION AGENCY OFFICE OF TRANSPORTATION AND AIR QUALITY ENGINE INTERNATIONAL AIR POLLUTION PREVENTION CERTIFICATE
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY OFFICE OF TRANSPORTATION AND AIR QUALITY ENGINE INTERNATIONAL AIR POLLUTION PREVENTION CERTIFICATE Manufacturer: Engine Family: Certificate Number: AB VOLVO
More informationReversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)
Simple, reliable efficient heat pump! Equipped with µconnect controller HFC R410A CERTITA CERTIFIED * Cooling capacity: 5 to 16.5 kw Heating capacity: 6 to 19 kw *except 75HT OPTION HEAT PUMP HEATING (30/35
More informationFixed Displacement Bent Axis Axial Piston Pumps TPB 70 - TAP 70
HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES Certified Company ISO 9001:2015-14001:2015 ISO 9001:2015 Certificate N 12-Q-0200545-TIC ISO 14001:2015 Certificate N 12-E-0200545-TIC
More informationDate: Project #: Engineer: Prepared By: Bid Date:
NEOTHERM Hydronic Boiler NTH Hydronic Boiler Indoor Sizes 285-850 Date: Submittal Data Project #: Engineer: Project Name: Prepared By: Location: Bid Date: Contractor: Standard Equipment High condensing
More informationCALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function
Pre-assembled distribution manifolds for radiant panel systems series & / NA Function Distribution manifolds for radiant panel systems are used to optimally distribute the heating fluid in floor heating
More informationTechnical Product Submittal
1. General Specifications 1.01 Certifications 1) SRCC OG-100 Technical Product Submittal Oventrop evacuated tube solar thermal collector OVSOL 5-8, 8 tube collector and OVSOL 5-16, 16 tube collector SRCC
More informationCH 450. High Tech Line. Self-Erecting Hydraulic Piling Rig
CH 450 High Tech Line Self-Erecting Hydraulic Piling Rig CH 450 MULTIPURPOSE HYDRAULIC RIGS FOR DIFFERENT DRILLING TECHNOLOGIES. The winning solution for job sites that require fast operating times. Truly
More informationDesign Criteria Data
RENO/CANNON INTL NV Latitude = 39.5 N WMO No. 72488 Longitude =119.7 W Elevation = 44 feet Period of Record = 1973 to 1996 Average Pressure = 25.57 inches Hg Design Criteria Data Mean Coincident (Average)
More informationInnovo Condensing high efficiency water heater
Condensing high efficiency water heater IR 12-160/20-160/12-200/20-200/24-245/32-245/ 24-285/32-285/32-380 A Fully room-sealed condensing high efficiency water heater Automatic gas/air premix burning system
More informationVIESMANN VITOTRANS 100 Plate heat exchanger
VIESMANN VITOTRANS 100 Plate heat exchanger Datasheet Part numbers and prices: see pricelist VITOTRANS 100 Type PWT For transfer stations from heat supply networks, for system separation in heating systems
More informationPRODUCT RANGE A COMPLETE RANGE OF BURNERS FROM 17 TO kw
www.ecoflam-burners.com PRODUCT RANGE 2015 A COMPLETE RANGE OF BURNERS FROM 17 TO 34000 kw CUTTING-EDGE BURNERS FOR HEATING AND INDUSTRIAL APPLICATIONS Our proposal Ecoflam offers a full range of blown
More informationLonglife hybrid solar battery systems with fuel cell technology
Ihr Garant für sichere Energie Longlife hybrid solar battery systems with fuel cell technology 09.June 2011 Michael Tausch Accumulatorenwerke HOPPECKE Carl Zoellner & Sohn GmbH Bontkirchener Straße 1 D-59929
More informationNCC Leisure Battery Verification Scheme. Leisure Accommodation Vehicles
The UK trade body for the caravan, motorhome, caravan holiday and park home industry. NCC Leisure Battery Verification Scheme Leisure Accommodation Vehicles Page 1 of 11 1 Scope The NCC Battery Verification
More informationOPERATION AND INSTALLATION
OPERATION AND INSTALLATION RESIDENTIAL SOLAR PUMP STATION» SE FLOWSTAR PUMP STATION Table of Contents 1 For your safety 1.1 About this manual 1.2 Designated use 1.3 Qualification of the installer 1.4 Hand-over
More information3/2 ways/positions flow diverters
Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 3/2 ways/positions flow diverters RE 18302-02/12.09 1/8 L705... (VS81-VS82-VS84-VS85) Size 6 Series 00
More informationThermostatic Control Valve
Thermostatic Control Valve Model J Typical applications Lubricating oil temperature control Jacket water high temperature (HT) Secondary water low temperature (LT) Heat recovery Water saving applications
More informationFO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com
FO-BV Series Fixed-orifice balancing and control valves Technical Data Sheet WattsIndustries.com Description FO-BV Series fixed-orifice threaded valves are designed for flow control and monitoring in climate
More informationFOOD SERVICE VEHICLE SPECIAL EVENT BUSINESS LICENCE APPLICATION MUNICIPAL CODE CHAPTER 326 A-5
FOOD SERVICE VEHICLE SPECIAL EVENT COMPLETE DEFINITIONS AND LICENCE FEES ARE AVAILABLE ON THE CITY OF BRANTFORD WEBSITE AT WWW.BRANTFORD.CA NEW APPLICATION - $50.00 NEW APPLICATION - $100.00 Food Cart
More informationHeat Exchangers & Enhanced Surface
Tru-Twist Technology! Product Catalog Edition l A wor ld leader in enhanced heat transfer technology. Coaxial Heat Exchangers & Enhanced Surface Geothermal Renewable Energy Turbotec Products, Inc. Water
More informationCH 650. Self-Erecting Hydraulic Piling Rig. High Tech Line
CH 650 Self-Erecting Hydraulic Piling Rig High Tech Line CH 650 The Comacchio self-erecting rigs are available in CPD (Cilynder Pull Down) and WPD (Winch Pull Down) versions and both are designed for easy
More information6/2 ways/positions flow diverters
Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 6/2 ways/positions flow diverters RE 18302-07/12.09 1/8 L753... (VS311-VS312-VS315) Size 10 Series 00
More informationCALEFFI. FLOWCAL Automatic flow balancing valve with polymer cartridge. 121 series 01141/11 NA. Function
FLOWCAL Automatic flow balancing valve with polymer cartridge 121 series REGISTERED BSI EN ISO 9001:2000 Cert. n FM 21654 UNI EN ISO 9001:2000 Cert. n 0003 CALEFFI 01141/11 NA Function The FlowCal automatic
More information950x. Description. Part List
Via Circonvallazione, 308 Valduggia (VC), Italy Tel: +39 063 4789 Fax: +39 063 47895 950x Variable Orifice Bronze Double Regulating Valve valvoindustria ing.rizzio s.p.a. Description Variable orifice bronze
More informationSDR-26 (160 PSI) SDR-21 (200 PSI) SDR-17 (250 PSI) MINIMUM WALL (IN.) 20 LENGTH. 1.5" 1.900" N/A N/A N/A.090" ".419 lbs..415 lbs.
u ASTM D2241 PRESSURE PIPE Gasketed Pipe Specifications Northern Pipe Products ASTM D2241 IPS Pressure Rated Pipe is manufactured from compounds conforming to cell class 12454 in accordance with ASTM D1784.
More informationTEST REPORT No a
AGRICULTURAL MACHINES FUNCTIONAL AND SAFETY TESTING SERVICE TEST REPORT No. 47 002a TANK FOR AGRICULTURAL SPRAYERS: SERIE LINEA TC 600 (extension: 47.002b Serie Linea TC 1000; 47.002c - Serie Linea TC
More informationTANZANIA BUREAU OF STANDARDS
EDC 5 (5235) P3 Mini-Grid Systems DRAFT TANZANIA STANDARD (Draft for comments only) Part 2: Application of Inverters TANZANIA BUREAU OF STANDARDS TBS 2017 First Edition 2017 T able of content 1 2 3 4 5
More informationCLIMAGUARD Outdoor Heat Exchangers
Product Overview : CLIMAGUARD Outdoor Heat Exchangers TX23 Model TX38 Model TX52 Model 132 Product Overview : Lab- and field-tested to seal out extreme weather CLIMAGUARD Outdoor Heat Exchangers PRODUCT
More informationOpening hours Monday - Friday, 8.00am pm Weekends and Bank Holidays, 8.30am pm We are closed on Christmas Day and New Year s Day.
0844 871 1525 Opening hours Monday - Friday, 8.00am - 6.00pm Weekends and Bank Holidays, 8.30am - 2.00pm We are closed on Christmas Day and New Year s Day. baxi.co.uk info@baxi.co.uk Baxi Brooks House,
More informationTHERMOSETTER Recirculation thermal balancing valve
THERMOSETTER Recirculation thermal balancing valve 116 series 01325/17 NA ACCREDITED Function ISO 9001 FM 21654 The THERMOSETTER adjustable thermal balancing valve is used for automatic balancing of recirculation
More information1 / 33. TÜV Rheinland (Shanghai) Co., Ltd Solar/ Fuelcell Technologies. Test Report
1 / 33 TÜV Rheinland (Shanghai) Co., Ltd Solar/ Fuelcell Technologies Test Report Qualification of a Solar Collector in accordance with DIN EN 129751: 2011; DIN EN 129752: 2006 TÜV Report No.: 154035663_EN_ETC30_Report_Gao
More informationTPV 4000 (EX 28-41) Variable Displacement Closed Loop System Axial Piston Pump HY-TRANS THE TRANSMISSION LINE OF HANSA-TMP HT 16 / M / 280 / 1008 / E
HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES Via M.L. King, 6-41122 MODENA (ITALY) Tel: +39 059 415 711 Fax: +39 059 415 729 / 059 415 730 INTERNET: http://www.hansatmp.it E-MAIL:
More information2 - way valve (NO), pressure relieved (PN 25) VG - external thread VGF - flange
Data sheet 2 - way valve (NO), pressure relieved (PN 25) VG - external thread VGF - flange Description VG and VGF are pressure relieved 2-way normally open (NO) valves, designed to be combined with: -
More information