Inverter Duty AC Motors

Size: px
Start display at page:

Download "Inverter Duty AC Motors"

Transcription

1 inverter_duty_ac_motors.fm Page 225 Tuesday, December 17, :12 PM RPM AC RPM III Medium DC Motors Index 225

2 Index RPM III Medium DC Motors RPM AC Inverter Duty Vector Inverter Duty Totally Enclosed - IP44, Washdown - IP55 Electrical Characteristics Key Information Phase: 3 Duty Cycle: Continuous Definitions: Frequency: 60 Hz Insulation: Class F These motors have a special inverter duty design not Ambient: 40 Degrees C Temp. Rise: Class B covered by EPAct efficiency levels Service Factor: 1.0 Application Information For variable speed 1000:1 constant torque applications T Frames IP44 Materials: Conduit Box: Bearing Type: Bearing Protection: Shaft Material: Nameplate Material: Drain Type & Location: Additional Features: 56T - 180T Frames IP55 Construction Features Steel frame and conduit box (56 frames). Aluminum frame and conduit box ( frames). End shields are aluminum. Oversized, top mounted with F1 & F2 lead outlets Double shielded ball High strength carbon steel Adhesive Mylar Weep holes in both end shields Includes 3 NC thermostats Materials: Steel frame (56 frames). Aluminum frame ( frames). Conduit box is cast aluminum. End shields are cast iron. Conduit Box: Oversized, top mounted with F1 & F2 lead outlets Bearing Type: Double sealed ball Bearing Protection: Lip seal Shaft Material: 300 Stainless steel Nameplate Material: Adhesive Mylar Drain Type & Location: T-drains Additional Features: Includes 3 NC thermostats Warranty (From Date Of Manufacture / From Date Of Installation): (24/12) Nameplate Agency Approvals: CE, CSA, UR 226

3 Vector Inverter Duty Totally Enclosed - IP44, Washdown - IP55 C-Face Foot Mounted 1/3-5 HP With Encoder HP 1/3 1/2 3/ Speed RPM Base CHP Voltage Frame Enclosure Number C-Face Foot Mounted 1/3-5 HP Without Encoder HP For encoder kits # K00T0002 (H-20) and K00T0005 (SL56) see RPM accessories page See stock modifications for installing encoder kits Norm. Stock Notes Dimension Sheet /460 FB56C TENV P56H5302 $1,450 REM03 Y /460 FB56C TENV P56H5305 1,480 REM03 Y /460 FB56C TENV P56H5301 1,460 REM03 Y /460 FB56C TENV P56H5304 1,510 REM03 Y /460 FB56C TENV P56H5300 1,490 REM03 Y /460 FB56C TENV P56H5303 1,540 REM03 Y /460 WC143TC TENV P14A5800 1,746 REM03 Y /460 WC143TC TENV P14A5803 1,600 REM03 Y /460 WC143TC TENV P14A5801 1,806 REM03 Y /460 WC145TC TENV P14A5804 1,655 REM03 Y /460 WD145TC TENV P14A5802 1,804 REM03 Y /460 WD145TC TENV P14A5805 1,675 REM03 Y /460 WE182TC TENV P18A6101 2,031 REM03 Y /460 WE182TC TENV P18A6103 1,880 REM03 Y /460 WE184TC TEBC P18A6102 2,503 REM03 Y /460 WE184TC TEBC P18A6104 2,345 REM03 Y Synch RPM Voltage Frame Enclosure Number Norm. Stock Notes Dimension Sheet /460 FB56C TENV P56H6302 $343 RPMST N / /460 FB56C TENV P56H RPMST Y /460 FB56C TENV P56H RPMST N /460 FB56C TENV P56H RPMST N / /460 FB56C TENV P56H RPMST Y /460 FB56C TENV P56H RPMST N /460 FB56C TENV P56H RPMST N / /460 FB56C TENV P56H RPMST Y /460 FC56C TENV P56H RPMST N /460 WC143TC TENV P14A RPMST N /460 WC143TC TENV P14A RPMST Y /460 WC143TC TENV P14A RPMST N /460 WC143TC TENV P14A RPMST N /460 WC143TC TENV P14A RPMST Y /460 WE145TC TENV P14A RPMST N /460 WD145TC TENV P14A RPMST N /460 WD145TC TENV P14A RPMST Y /460 WE182TC TENV P18A RPMST N /460 WE182TC TENV P18A RPMST Y /460 WE184TC TEBC P18A RPMST N /460 WE184TC TEBC P18A RPMST Y Inverter capable. See page 14 Approx. Wt. (lb.) Approx. Wt. (lb) RPM AC RPM III Medium DC Motors Index 227

4 Index RPM III Medium DC Motors RPM AC Inverter Duty Vector Inverter Duty Totally Enclosed - IP44, Washdown - IP55 C-Face Foot Mounted 1/3-3 HP Washdown With Encoder HP 1/3 1/2 3/ Synch RPM Voltage Frame Enclosure Number C-Face Foot Mounted 1/3-3 HP Washdown Without Encoder For encoder kits # K00T0002 (H-20) and K00T0005 (SL56) see RPM accessories page See stock modifications for installing encoder kits Norm. Stock Notes Dimension Sheet /460 FB56C TENV-EZ P56H5322 $1,590 REM03 N /460 FB56C TENV-EZ P56H5325 1,620 REM03 N /460 FB56C TENV-EZ P56H5321 1,600 REM03 N /460 FB56C TENV-EZ P56H5324 1,650 REM03 Y /460 FB56C TENV-EZ P56H5320 1,630 REM03 N /460 FB56C TENV-EZ P56H5323 1,680 REM03 N /460 WC143TC TENV-EZ P14A5820 1,886 REM03 N /460 WC143TC TENV-EZ P14A5823 1,740 REM03 Y /460 WD143TC TENV-EZ P14A5821 1,946 REM03 N /460 WC143TC TENV-EZ P14A5824 1,795 REM03 Y /460 WE143TC TENV-EZ P14A5822 1,944 REM03 N /460 WD143TC TENV-EZ P14A5825 1,815 REM03 Y /460 WE182TC TENV-EZ P18A6121 2,171 REM03 N /460 WE182TC TENV-EZ P18A6123 2,485 REM03 Y Approx. Wt. (lb) HP Synch Norm. Dimensions Approx. RPM Voltage Frame Enclosure Number Stock Notes Sheet Wt. (lb.) /460 FB56C TENV-EZ P56H6322 $483 RPMST N / /460 FB56C TENV-EZ P56H RPMST N /460 FB56C TENV-EZ P56H RPMST N /460 FB56C TENV-EZ P56H RPMST N / /460 FB56C TENV-EZ P56H RPMST N /460 FB56C TENV-EZ P56H RPMST N /460 FB56C TENV-EZ P56H RPMST N / /460 FB56C TENV-EZ P56H RPMST N /460 FB56C TENV-EZ P56H RPMST N /460 WC143TC TENV-EZ P14A RPMST N /460 WC143TC TENV-EZ P14A RPMST Y /460 WD143TC TENV-EZ P14A RPMST N /460 WD143TC TENV-EZ P14A RPMST N / /460 WC143TC TENV-EZ P14A RPMST Y /460 WE145TC TENV-EZ P14A RPMST N /460 WE145TC TENV-EZ P14A RPMST N /460 WD145TC TENV-EZ P14A RPMST Y /460 WE182TC TENV-EZ P18A RPMST N /460 WE182TC TENV-EZ P18A RPMST Y Inverter capable. See page

5 Vector Inverter Duty Totally Enclosed - IP44, Washdown - IP55 Encoder Kits The following kits include encoder and all mounting hardware with coupling. New blower is required for TEBC. Encoder Ratings: All encoder kits are rated as follows: single output, 1024 PPR, two channel quadrature output (A and B) with complementary outputs, 5-15 VDC input. SMALL RPMAC TENV / Coupled Bearingless TEBC Dynapar H20 Lakeshore SL56 (2) Frame Size Order Order Number Number 56, 140, K00T0002 $800 RPMAC W180T K00T0003 (1) 400 RPMAC K00T0005 $1,500 RPMAC (1) New blower required for H20 when used with TEBC enclosure (2) Cannot be used on TEFC enclosure RPM AC RPM III Medium DC Motors Index 229

6 Index RPM III Medium DC Motors RPM AC Inverter Duty Explosion Proof - Extra Tough - Inverter Duty Totally Enclosed - IP54 Electrical Characteristics Key Information Phase: 3 Duty Cycle: Continuous Definitions: Frequency: 60 Hz Insulation: Class F EMT = E-Master motors that meet EPAct efficiencies Ambient: 40 Degrees C Temp. Rise: Class B XET = Premium efficient motors that exceed EPAct Service Factor: 1.0 efficiency levels Warranty (From Date Of Manufacture / From Date Of Installation): EMT (24/12), XET (36/24) Application Information Nameplate Agency Approvals: General purpose industrial applications containing hazardous gas, vapor, dust fibers, constant torque, Hz. CSA, UL continuous constant HP (UL file E6881) T Frames C-Face Foot Mounted 1/3-2 HP Construction Features UL ing Division 1 Class 1 Groups C & D, Class 2 Groups F & G, T3C Materials: Plate steel frame and fan cover, cast iron conduit box and end shields Conduit Box: F1 mounted Bearing Type: Double sealed ball bearings Bearing Protection: External slinger Shaft Material: 400 series stainless steel Nameplate Material: Stainless steel Drain Type & Location: Additional Features: HP 1/3 1/2 3/ HP and lower 56 frame motors are thermally protected with an auto thermal. 1HP and higher 140 frame motors are thermally protected with thermostats. Synch RPM Voltage Frame Enclosure Number * Stock modifications are not available on explosion proof motors. See modification catalog. - Inverter capable. See page 14 Norm. Stock Notes Dimension Sheet /460 HM56C FCXP-EMT P56X4070 $693 REM03 Y /460 HM56C FCXP-EMT P56X REM03 Y /460 HB56C FCXP-EMT P56X REM03 Y /460 HB56C FCXP-EMT P56X REM03 Y /460 HM56C FCXP-EMT P56X REM03 Y /460 HK56C FCXP-EMT P56X REM03 Y /460 HB56C FCXP-EMT P56X REM03 Y /460 HK56C FCXP-EMT P56X REM03 Y /460 HK143TC FCXP-XET P14X RXM03 Y /460 HB143TC FCXP-XET P14X RXM03 Y /460 HB143TC FCXP-XET P14X RXM03 Y /460 HD145TC FCXP-XET P14X RXM03 Y /460 HK143TC FCXP-XET P14X RXM03 Y /460 HK145TC FCXP-XET P14X RXM03 Y /460 HC145TC FCXP-XET P14X9132 1,050 RXM03 Y /460 HJ145TC FCXPXET P14X RXM03 Y Approx. Wt. (lb) 230

7 LV (Low Voltage) Inverter Duty Totally Enclosed - IP44 Electrical Characteristics Key Information Phase: 3 Duty Cycle: Continuous Definitions: Frequency: 60 Hz Insulation: Class F+ TEFC = E-Master motors that meet EPAct efficiencies Ambient: 40 Degrees C Temp. Rise: Class B Warranty (From Date Of Manufacture / From Date Of Installation): Service Factor: 1.15 (24/12) Application Information Nameplate Agency Approvals: CE, CSA, UL Designed for optimized performance from a 115/230 volt single phase input - three phase output variable frequency controller. 56 Frames Materials: Conduit Box: Bearing Type: Bearing Protection: Shaft Material: Nameplate Material: Drain Type & Location: C-Face Foot Mounted 1/3-1 HP HP Construction Features Rolled steel frame, conduit box and fan cover, Aluminum end shields Oversized, top mounted with F1 & F2 lead outlets Double shielded ball bearings High strength carbon steel Mylar Weep hole in both end shields Synch RPM Voltage Frame Enclosure Number 1/ /230 FB56C TEFC P56X1426 $262 REM01 Y 24 1/ /230 FB56C TEFC P56X REM01 Y 28 3/ /230 FK56C TEFC P56X REM01 Y /230 FK56C TEFC P56X REM01 Y 32 - Inverter capable. See page 14 Norm. Stock Notes Approx. Wt. (lb) RPM AC RPM III Medium DC Motors Index 231

8 Index RPM III Medium DC Motors RPM AC Inverter Duty Inverter Duty GENERAL PRODUCT DESCRIPTION The V*S Master motor, like the RPM AC motor, was designed from the beginning to be a Variable Speed Inverter Duty motor. It is not a fixed speed motor design that has been re-rated to be an Inverter Duty motor. All V*S Master motors are designed to operate from zero speed to base speed with full load current and torque below the class F temperature rise. Each V*S Master has three thermostats, one per phase, to provide Inverter Duty thermal protection. The V*S Master 1800 rpm, 1200 rpm and 900 rpm motors truly provide the performance of a blower-cooled motor in a TEFC enclosure. This means that the customer does not need to purchase and mount a blower motor starter or install threephase power leads to the blower motor. V*S Master Features 1000:1 Constant Torque - This means that the V*S Master is designed to operate from zero to base speed continuously with full load current and torque. The V*S Master TEFC and TENV motors are designed to draw nameplate current continuously at zero speed without exceeding the class F temperature rise. The industry standard is to call this capability 1000:1 Constant Torque, some manufacturers identify this capability 1000:1 Constant Torque, some manufactures identify this capability as 2000:1, 3000:1, infinity:1, etc. All of these terms describe the same capability of the AC Motor, one is not better than another. Standard NEMA T Frames - V*S Master motors, 2 HP to 500 HP are all in standard NEMA frames (Larger motors are in above NEMA frames 447T through L449T). Cast Iron Frames - All V*S Master motors are in cast iron frames with cast iron end shields. Adding XT features also provides a cast iron fan cover and conduit box along with other XT features. 200% Overload Torque - Each V*S Master has an electrical design that will provide 200% overload torque for one minute from zero to base speed. Constant Horsepower - The standard V*S Master is designed to provide constant horsepower to 1.5 times base speed. Thermostats - Each V*S Master motor has three normally closed thermostats connected in series, one in each phase of the motor. One set of P1 and P2 leads is brought to the conduit box. If any of the thermostats opens, the P1 and P2 circuit opens. Encoder Provisions - Each V*S Master has encoder provisions as a standard feature, even if an encoder is not ordered with the motor. 232

9 Inverter Duty V*S Master Features (cont) Insulated Bearing - Every 440 frame (444T through L449T) has an opposite drive end insulated bearing as standard to reduce the chances of the bearings being damaged by shaft currents. In large motors (440 frames) it is quite common to have shaft currents caused by magnetic flux dissymmetry, one insulated bearing will usually protect against this source of shaft currents. Other modifications, such as Current Shield can be added to protect against other sources of shaft currents. Corona Free Insulation - Every V*S Master motor has Reliance Electric s Corona Free insulation system that exceeds the insulation requirements described in NEMA MG1-1998, part 31, for Definite Purpose, Inverter-Fed Polyphase motors. Class F Insulation - V*S Master motors have class F insulation and operate below class F temperature rise. Nearly all TEFC V*S Master motors operate with a class B rise over a 4:1 speed range. That means that most TEFC 1800-rpm motors will operate with a class B rise over a 450 rpm to 1800 rpm (covers most actual operating conditions) speed range. 40 C ambient - Standard on nameplate, many V*S Master motors are suitable for higher ambient temperatures with only a nameplate change. Continuous Duty - Contact Reliance Electric for different duty cycles 1.0 Service Factor - Because V*S Master motors are designed for Inverter Duty applications, not across-the-line designs, all designs have a 1.0 SF as standard on inverter power. Re-greaseable bearings - For longest life in severe duty applications, all V*S Master motors have re-greaseable bearings. Stainless Steel Nameplates - Every V*S Master motor has an Inverter Duty stainless steel nameplate with the electrical design number, magnetizing current, constant torque speed range, number of poles, rotor inertia, bearing numbers and other NEMA data. F1 Mounting - Conduit box location is F1 as standard on NEMA frame motors (IEC motors have conduit box on opposite side as standard). F2 or top mounted conduit boxes are available as a modification. Visit web site for additional Inverter Duty Motor information. Download the V*S Master Data Sheet, RAPS V*S Master motors are CSA, Canadian Standards Association, certified and carry the monogram on the nameplate. All accessories attached the motor must also carry their own CSA mark. Reliance Electric s file number for V*S Master motors is, LR7861. The European Committee for Electrotechnical Standardization defines compliance standards for the CE mark required on motors shipping to Europe. It is available upon request on all V*S Master motors. The V*S Master IEC motors carry the CE mark as standard. All accessories attached to the motor must also carry their own CE mark. V*S Master motors carry the Underwriters Laboratories, Inc., Recognized Component mark for electric motors used in ordinary locations (not explosion-proof). Reliance Electric s file number for V*S Master motors is, E RPM AC RPM III Medium DC Motors Index 233

10 Index RPM III Medium DC Motors RPM AC Inverter Duty Inverter Duty Optimum Pole Reliance Electric s Inverter Duty Motors are based on the use of optimum pole design. Unlike fixed speed motors, Inverter-Fed motors can have different base speeds based on different base frequencies. For example, a four-pole motor designed with a base frequency of 40 hertz and a base voltage of 460 vac will have a base synchronous speed of 1200 rpm. Reliance Electric selects the number of poles to be used on an Inverter Duty motor so that the torque density, speed range, efficiency, power factor, overload capability and acoustic noise can be optimized. Like the Inverter Duty RPM AC motor, most of the Inverter Duty V*S Master motors in frames 180T through 400T are four-pole designs, regardless of the base speed. The Inverter is set to match the motor nameplate, for example, 50 hp, 1200 rpm, 460 vac, 40 hertz, and 4 poles. On larger frames of Inverter Duty AC motors, many of the designs are six-pole, regardless of the base speed. This approach has also been used in Reliance Electric s DC Motor designs for years. Most of the DC motor ratings 500 hp and less are four-pole designs, regardless of the base speed. For more information on optimum pole design, go to Reliance Electric s web site, and print the white paper, Optimum Pole Configuration of A-C Induction Motors used on Adjustable Frequency Power Supplies, B

11 Inverter Duty AC Motor 1000:1 Constant Torque TEFC & TENV Features Cast Iron frame and end brackets Three normally closed thermostats, one per phase Shaft drilled and tapped for installation of stub shaft 200% overload torque for one minute below base speed Class F insulation Continuous Duty 40 C Ambient Inverter Duty - not for across the line operation See previous Product Pages for additional features HP HP Synch RPM Voltage Frame Enclosure Number Norm. Stock 460V AMPS Dimensions Sheet Approx. Wt. (lb.) / TC TENV P18G1187 $1,179 RVM22 Y / TC TENV P18G RVM22 Y / T TENV P21G3205 1,484 RVM22 N /460 L184TC TENV P18G1189 1,106 RVM22 Y /460 L215T TENV P21G3206 1,720 RVM22 N /460 L215TC TENV P21G1162 1,383 RVM22 Y / T TEFC P25G3205 2,170 RVM22 N / TC TENV P25G1152 1,664 RVM22 Y /460 L215TC TEFC P21G1164 1,605 RVM22 Y / T TEFC P25G3206 2,458 RVM22 N / TC TENV P25G1150 2,137 RVM22 Y T TEFC P28G3205 2,903 RVM22 N T TENV P28G3208 2,402 RVM22 N TC TEFC P25G1151 2,110 RVM22 Y T TEFC P28G3206 3,301 RVM22 N T TENV P32G3210 3,198 RVM22 N TC TEFC P28G1083 2,668 RVM22 Y T TEFC P32G3205 4,333 RVM22 N T TENV P32G3209 4,963 RVM22 N T TEFC P28G3207 2,813 RVM22 Y T TEFC P32G3206 5,303 RVM22 N T TENV P36G3209 6,063 RVM22 N T TEFC P32G3207 3,949 RVM22 Y T TEFC P36G3205 6,388 RVM22 N T TENV P40G3208 7,526 RVM22 N T TEFC P32G3208 4,826 RVM22 Y T TEFC P36G3206 7,913 RVM22 N T TEFC P36G3207 5,979 RVM22 Y T TEFC P40G3205 9,443 RVM22 N T TEFC P36G3208 7,489 RVM22 Y T TEFC P40G ,340 RVM22 N T TEFC P40G3207 9,680 RVM22 Y T TEFC P44G ,356 RVM22 N NOTE: For the current version of Inverter Duty Motor dimension sheets, connection diagrams, design curves, etc., visit RPM AC RPM III Medium DC Motors Index 235

12 Index RPM III Medium DC Motors RPM AC Inverter Duty Inverter Duty AC Motor 1000:1 Constant Torque TEFC & TENV HP cont HP Synch RPM Voltage Frame Enclosure Number Norm. Stock 460V AMPS Dimensions Sheet Approx. Wt. (lb.) T TEFC P44G3207 $12,015 RVM22 Y T TEFC P44G ,998 RVM22 N T TEFC P44G ,339 RVM22 Y T TEFC P44G ,502 RVM22 N T TEFC P44G ,990 RVM22 Y T TEFC P44G ,996 RVM22 N T TEFC P44G ,003 RVM22 Y T TEFC P44G ,800 RVM22 N T TEFC P44G ,014 RVM22 Y L449T TEFC P44G ,011 RVM22 N L449T TEFC P44G ,811 RVM22 N L449T TEFC P44G ,500 RVM22 N L449T TEFC P44G ,315 RVM22 N (1) L449T TEFC P44G ,680 RVM32 N NOTE: For the current version of Inverter Duty Motor dimension sheets, connection diagrams, design curves, etc., visit (1) - Rated only for 4:1 constant torque speed range VXS - Inverter Duty The VXS TEFC, TENV and TEBC motors have been replaced by the Inverter Duty TENV and TEFC V*S Master motor and/or the Inverter Duty RPM AC motor. Contact Rockwell Automation Sales Engineers representing DODGE and Reliance Electric brands of products for applications where the V*S Master nor the RPM AC motor provide a suitable functional replacement for the VXS motor. The TEFC Inverter Duty V*S Master gives you the performance of a TEBC motor, full load torque from 0 to base speed, without the motor mounted blower. 236

13 V*S Master Encoder Kits 60HP, TEFC, 364T with HS35 ENCODER Encoder With Mounting Kit - Requires Both Numbers Frame Enclosure Type Supply Voltage Output/PPR Encoder Mounting Kit 180T-250T TENV BEI HS35 5 to 15 vdc Single/1024 K99G32 $1,000 K18G22 $100 RVM22 180T-440T TEFC BEI HS35 5 to 15 vdc Single/1024 K99G32 1,000 K21G RVM22 180T-250T TENV BEI HS35 5 to 26 vdc Single/1024 K99G34 1,000 K18G RVM22 180T-440T TEFC BEI HS35 5 to 26 vdc Single/1024 K99G34 1,000 K21G RVM22 180T-250T TENV MagCoder HS35M 5 to 24 vdc Single/1024 K99G35 1,250 K21G RVM22 180T-440T TEFC MagCoder MS35M 5 to 24 vdc Single/1024 K99G35 1,250 K21G RVM22 180T-250T TENV Avtron M3 5 to 18 vdc Single/1024 K99G33 2,300 K18G RVM22 210T-440T TEFC Avtron M3 5 to 18 vdc Single/1024 K99G33 2,300 K21G RVM22 BEI HS35 - This is an optical hollow shaft encoder with a single output, 1024 ppr, that has two channel quadrature outputs (A and B) with complementary outputs and a marker pulse (Z). Two versions of the encoder are stocked, 5 to 15 vdc input and a 5 to 26 vdc input, both are rated for 70 degrees C ambient, 6000 rpm maximum and have a IP65 enclosure rating. This encoder comes with a protective cover as shown in the above picture. See BEI s web site for additional information, Avtron M3 - This is an optical hollow shaft encoder with a single output, 1024 ppr, that has two channel quadrature outputs (A and B) with complementary outputs and a marker pulse (Z). The encoder requires 5-18 vdc input and is rated for 85 degrees C ambient, 5000 rpm maximum and has a totally sealed, cast aluminum housing with polyurethane enamel paint. See Avtron s web site for additional information, MagCoder HS35M - The MagCoder HS35M is a hollow shaft encoder with a single output, 1024 ppr, that has two channel quadrature outputs (A and B) with complementary outputs and a marker pulse (Z). The encoder requires 5-26 vdc input and is rated for 80 degrees C ambient, 3600 rpm maximum and has a IP65 enclosure rating. The MagCoder uses magneto resistive technology which makes it immune to common contaminants. The MagCoder HS35M was previously identified as a LakeShore product, but is now manufactured by Danaher Controls which also makes DynaPar encoders. For more information on LakeShore or DynaPar encoders, see web site NOTES: For mounting of the above encoders and kits by Reliance Electric, see the Modification Center price pages of this section. See the Variable speed Catalog or the Configurator for a complete list of encoders available on production Inverter Duty AC motor orders. RPM AC RPM III Medium DC Motors Index 237

14 Index RPM III Medium DC Motors RPM AC Inverter Duty Inverter Duty Modification Center Ordering Instructions Before Entering an Order 1. Determine the proper stock model number to be modified and check availability. 2. Be sure the modifications required are available. 3. XP modifications are not available. See modification catalog. How to an Order 1. Record the list price of the required motor model number plus add all list modification adders and multiply it by the appropriate discount symbol. 2. Record total motor net. How and Where to Enter an Order Reliance Distributors: Can phone their orders to Rockwell Automation Reliance Electric Inside Sales Representative or send a fax to: Or for those not assigned an Inside Sales Representative, you may call the main switchboard at District Sales Engineers: May place orders to the Modification Centers via OMS. Cancellation or Changes to an Order To cancel an order for a motor after it is modified, but before it ships, a cancellation charge of double the modification charge will be invoiced to the customer. Any MOD order cancelled before modification is completed is subject to 25% cancellation charge. Once shipped, modified motors cannot be returned. Delivery Cycle The delivery cycle will be subject to the availability of stock motors and parts. The Modification Center is designed to process and ship units as quickly as possible; therefore, Hold for Approval and other similar conditions are not available on Modification Center orders. For best delivery results, check stock availability and reserve the motor prior to order entry. Typically, modifications will require 2 to 7 business days, once the order is entered. Orders for more than 5 units may require additional delivery time. Hours The Modification Centers are operated from 7 am to 3 pm Monday through Friday. 238

15 Inverter Duty Modification Center Modification Description Frame Enclosure 1. BEARINGS: (per set / per motor) Shielded bearings (specify double or single shielded bearing, Mfg. is Reliance Option) Adder Notes ALL $ ALL ALL ALL ALL Sealed bearings-convert to permanently lubricated sealed bearings 2. BRAKES: Mount double c-face DODGW DBSS brake kit to c-face motor Standard Enclosure 3 ft. lb. 56C. 140TC ALL NON XP 1,350 6 ft. lb. 56C. 140TC ALL NON XP 1, ft. lb. 56C. 140TC ALL NON XP 1, ft. lb. 56C. 140TC ALL NON XP 1, ft. lb. 56C. 140TC ALL NON XP 1, ft. lb. 56C. 140TC ALL NON XP 1,900 Easy Clean (Washdown) Enclosure 3 ft. lb. 56C. 140TC ALL NON XP 1,600 6 ft. lb. 56C. 140TC ALL NON XP 1, ft. lb. 56C. 140TC ALL NON XP 1, ft. lb. 56C. 140TC ALL NON XP 1, ft. lb. 56C. 140TC ALL NON XP 2, ft. lb. 56C. 140TC ALL NON XP 2, CONDUIT BOX: Mounting of stock box kits (price includes box): Convert to cast iron or oversize ALL ALL Auxiliary box attached to main conduit box ALL CONNECTIONS: Final connect dual to single voltage ALL ALL ALL COUPLING: Mount customer supplied finished bored 1/2 coupling - clearance ALL 280 fit only 6. DRAINS: One in each motor end bracket: Stainless steel T-drain ALL 690 Note: Mounting position must be specified e.g. F-1, W-1, etc. 7. DRIPCOVERS: Mounting of stock canopy kits (includes drip cover kits) This modification does not provide vertical lifting ENDSHIELDS: Note: Does not include seal, add seal modification, if required. Changing from std.end to C-face on drive end (C.I. N/A) 48,56,140 ALL 220 Changing from std. end to C-face with feet (Non-NEMA BA) ALL 550 Changing from std. end to C-face with feet (NEMA BA) ALL FAN COVER: (Cast Iron Fan Shroud and Conduit Box) TEFC TEFC TEFC 1, FRAME: Remove feet. (Note: add in conjunction with flange modification) Not returnable to stock 11. GREASE: Changing to special grease - based on availability / suitability: Mobil 28 or Aeroshell 7 low temperature or DC-44 (synthetic) high temperature grease * * Check Availability TENV TEFC TEFC TEFC TEFC ALL ALL ALL ALL ALL ALL ALL 1,110 RPM AC RPM III Medium DC Motors Index 239

16 Index RPM III Medium DC Motors RPM AC Inverter Duty 240 Inverter Duty Modification Center - cont Modification Description Frame Enclosure Adder 12. GREASE FITTINGS: Alemite 1610 or button head zerk fitting ALL $ GROUNDING: (All motors have provision for grounding) Clamp type in conduit box ALL INSULATION: (Addition of tropical, anti-fungus treatment to windings) ALL ALL ALL LEAD TERMINALS: Addition of eyelet - type lead terminals ALL 280 Compression type (Burndy, etc.) lead lugs ALL MOUNTING: (not available on L180T-L210T frames) F-1 to F-2/W6/W8/W5/W ALL ALL NAMEPLATES: Allows adding definite purpose nameplates or the addition of information. Characters of additional information will be available in 3/32 only. Over 25 characters will require an additional blank nameplate with the auxiliary nameplate charge added. Charges are per nameplate. Nameplates are stainless steel. Separate nameplate for customer data ALL 140 Additional data on motor nameplate ALL 140 Separately shipped re-rated nameplate for stock motor in the field ALL 420 (no CSA logo) Requires return of old nameplate. 18. SEALS: V-ring rubber slinger on drive end ALL SPACE HEATERS: (120, 240, 480 volt) Auxiliary box not included. See conduit boxes Mounting of standard strip heaters ALL ALL ALL ALL ENCODERS: Mounted on. All encoders are 1024 PPR, single quadrature output Series H-20 (K00T0002) 56, 140, WF180 TENV (RPMAC) 1,100 Series H-20 (K00T0002+K00T0003) WF180 TEBC (RPMAC) 1,600 Lake Shore SL56 (K00T0005) 56,140,WF180 TENV (only) 1,800 BEI hollow shaft HS TEFC & TENV 1,100 Avtron hollow shaft M TEFC & TENV 2,500 Lake Shore hollow shaft HS35M TEFC & TENV 1, TERMINAL BLOCK: IEC style terminal block or NEMA terminal strip in conduit box Limited to single voltage motors with three leads - specify voltage 22. THERMAL PROTECTION: Three normally closed (N.C.) thermostats, one per phase, included in all, except the 56 frame TEFC motors for single-phase inverters. * Check Availability NOTE: Under Enclosure, ALL does not include explosion proof (XP) enclosures TEFC TEFC TEFC TEFC 1,110 Notes

Inverter Duty and Inverter Duty - Vector Performance AC Motor Product Line

Inverter Duty and Inverter Duty - Vector Performance AC Motor Product Line Large AC Inverter Duty and Inverter Duty - Vector Performance AC Motor Product Line Inverter Duty 1/3-2 HP, 56-140 frame sizes, Explosion Proof, Class I, Groups C & D, Class 2, Groups F & G, XT - Extra

More information

RPMAC Inverter Duty Motors Stock Model Number Cross Reference List

RPMAC Inverter Duty Motors Stock Model Number Cross Reference List RPMAC Inverter Duty Motors Stock Model Cross Reference List L180 to RL210 Functional Replacement The following RL210 frames are intended to be only functional replacements of the L180 RPMAC frames, which

More information

RPM AC INTEGRAL HP INVERTER DUTY MOTORS

RPM AC INTEGRAL HP INVERTER DUTY MOTORS RPM AC INTEGRAL INVERTER DUTY MOTORS Table of Contents Page General Information......................... 242 General Features........................... 242 Standard Motor Features Agency Listing..........................

More information

Inverter Speed Ratio Information

Inverter Speed Ratio Information Inverter Speed Ratio Information Guidelines for Application of General Purpose,, Single Speed on Variable Frequency Drives Meets NEMA MG1-2006 Part 30 and Part 31 Section 4.4.2 Unless stated otherwise,

More information

Small and Medium DC Motors

Small and Medium DC Motors Large AC Small and Medium DC Motors RPM III Medium DC Motors General Information RPM AC Inverter Duty Inverter Duty AC Motors For pricing information or to place orders, go to www.ptplace.com M-222 RPM

More information

Blue Max 2000 Vector Duty 2000:1 Constant Torque Motors

Blue Max 2000 Vector Duty 2000:1 Constant Torque Motors Blue Max 2000 Vector Duty 2000:1 Constant Torque Motors Applications: Blue Max motors are used in variable frequency drive applications requiring full rated torque at zero speed, utilizing Closed- or Open-Loop

More information

Small and Medium DC Motors

Small and Medium DC Motors Small and Medium DC Motors Inverter Duty AC Motors RPM AC Inverter Duty RPM III Medium DC Motors General Information Introduction M-283 Introduction General Information RPM III Medium DC Motors Inverter

More information

Small & Medium AC General Purpose Motors. Description

Small & Medium AC General Purpose Motors. Description Totally Enclosed Fan Cooled Type CS 60 Hz 40 C Ambient Continuous Duty Class B.5 Service Factor Ball Bearing IP44 Designed for all general purpose industrial applications in a dusty, dirty and/or humid

More information

RPM AC MOTORS MODIFICATION INDEX

RPM AC MOTORS MODIFICATION INDEX RPM AC INVERTER DUTY MOTORS MODIFICATIONS INDEX RPM AC MOTORS MODIFICATION INDEX Page ADAPTER BASES OR RAILS Adapter Base................................................. B-64 Adapter Rails.................................................

More information

Horizontal Motors Conversions & Accessories Descriptions & Adders

Horizontal Motors Conversions & Accessories Descriptions & Adders Horizontal Motors Conversions & Accessories VERTICAL All Cast Iron Construction Cast Iron Conduit Box Adder: - 153 161 193 209 234 242 346 483 636 - - - Replacement of steel conduit box with cast iron

More information

5 Year Warranty Premium Efficiency, TEFC Enclosure Inverter Duty Motors Corona Resistant Magnet Wire CSA Certified, UL, CE NEMA MG1 (2003) Part 31,

5 Year Warranty Premium Efficiency, TEFC Enclosure Inverter Duty Motors Corona Resistant Magnet Wire CSA Certified, UL, CE NEMA MG1 (2003) Part 31, 5 Year Warranty Premium Efficiency, TEFC Enclosure Inverter Duty Motors Corona Resistant Magnet Wire CSA Certified, UL, CE NEMA M1 (003) Part 31, DefinitePurpose Inverter Fed Motors Inverter Shield TM

More information

Large AC Motors. Synchronous Reluctance Kiln Duty Submersible Accessories & Kits. Large AC Motors. Modifications Large AC M-211

Large AC Motors. Synchronous Reluctance Kiln Duty Submersible Accessories & Kits. Large AC Motors. Modifications Large AC M-211 Synchronous Reluctance Kiln Duty Submersible Accessories & Kits Modifications Large AC M-211 large_ac_motors.fm Page 212 Monday, December 15, 2003 3:47 PM, Quickship and Modifiable 250 HP - 1500 HP 3600

More information

General Purpose Three Phase Motors TEFC (IP55) High Efficiency. Standard Features

General Purpose Three Phase Motors TEFC (IP55) High Efficiency. Standard Features TM WEG W21 Severe Duty motors meet the most demanding severe duty application requirements. These TEFC motors are all cast iron construction, with enclosures rated IP55 to handle wet and dirty environments.

More information

SECTION MOTOR REQUIREMENTS for HVAC

SECTION MOTOR REQUIREMENTS for HVAC PART 1 GENERAL 1.1 SECTION INCLUDES A. Single-phase electric motors B. Three-phase electric motors 1.2 REFERENCES SECTION 23 05 13 MOTOR REQUIREMENTS for HVAC A. ABMA 9 - Load Ratings and Fatigue Life

More information

Inverter (Vector) Duty: micromax TM 1000:1 Constant Torque (TENV), 20:1 Constant Torque (TEFC) Totally Enclosed

Inverter (Vector) Duty: micromax TM 1000:1 Constant Torque (TENV), 20:1 Constant Torque (TEFC) Totally Enclosed Inverter (Vector) Duty: micromax TM 1000:1 Constant Torque (TENV), 20:1 Constant Torque (TEFC) Totally Enclosed Applications: Designed for direct replacement of PMDC or any other variable speed application

More information

THREE PHASE MOTORS RIGID BASE GENERAL PURPOSE Rigid Base

THREE PHASE MOTORS RIGID BASE GENERAL PURPOSE Rigid Base THREE PHASE MOTORS DRIP-PROOF RPM 60 HP Hz 1/4 1725 1725 S56 100027 $246 A 16 208-230/460 1.4 58.0 9.24 1/3 3450 48 101447 251 A 14 208-230/460 1.4 68.0 9.00 1725 48 100446 266 A 17 208-230/460 1.6 64.3

More information

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY TYPE AEHE, AEHH8N, AEHH8NCF, AEUH8NDC Effective 05-01-13 Supercedes 08-01-11 APPLICATIONS: Fans & Blowers Compressor Any Severe Duty/ Petro-Chem/ Pumps Mixers Pulp

More information

Premium Efficiency Exceeds Effciency Levels Mandated by CSA C390 and EPACT 92

Premium Efficiency Exceeds Effciency Levels Mandated by CSA C390 and EPACT 92 Premium Efficiency Exceeds Effciency Levels Mandated by CSA C390 and EPACT 9 Crown Triton TM Series Premium Efficiency Motors Experience Combined with Technology yundai Induction Motors use Finite Element

More information

Variable Speed Motor Products

Variable Speed Motor Products Variable Motor Products Why Baldor? Customer Preference 90% 2000 20% 1985 50% 1990 Percentage of research studies in which Baldor was chosen most preferred. For nearly 100 years, Baldor has strived to

More information

VARIABLE SPEED AC MOTORS 1/3-2,500 HP INVERTER DUTY MOTORS

VARIABLE SPEED AC MOTORS 1/3-2,500 HP INVERTER DUTY MOTORS VARIABLE SPEED AC MOTORS 1/3-2,500 HP INVERTER DUTY MOTORS IN 1904, RELIANCE ELECTRIC INTRODUCED THE WORLD'S FIRST VARIABLE SPEED MOTOR. FOR OVER 96 YEARS, RELIANCE ELECTRIC MOTORS HAVE LED THE INDUSTRY

More information

WATTSAVER PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE

WATTSAVER PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE The line of premium efficiency motors is now inverter capable. LEESON s unique IRIS voltage-spike-resistant insulation system is standard at no extra cost. motors

More information

Industrial and Commercial Duty IEC Motors

Industrial and Commercial Duty IEC Motors Industrial and Commercial Duty IEC Motors A Regal Brand Five product families delivering a world of opportunity LEESON Passport Series IEC Motors. There s a world of opportunity right here at home. The

More information

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT SECTION 230513 - COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Single phase electric motors. B. Three phase electric motors. 1.2 REFERENCE STANDARDS A. ABMA STD 9

More information

Three Phase Modifiable NEMA Horizontal Motors Accessories and Modifications

Three Phase Modifiable NEMA Horizontal Motors Accessories and Modifications 1. Altitude Standard motors are designed for 3,300 feet altitude and 40 C ambient temperature. Atmospheric conditions at higher altitudes inhibit the motor s ability to dissipate heat, resulting in an

More information

Family Frame Size Constant Torque Variable Torque Comments Super-E Motors 230, 460 and 575 Volts (1) (1) 20:1 10:1

Family Frame Size Constant Torque Variable Torque Comments Super-E Motors 230, 460 and 575 Volts (1) (1) 20:1 10:1 ac Motor adjustable speed range capabilities & Controls inverter drive and vector drive Inverter Drive and Vector Drive exceed all requirements of NEMA MG-1 Parts 30 and 31 for AC induction motors powered

More information

Product Information Packet EM3611T 3HP,1760RPM,3PH,60HZ,182T,3632M,TEFC,F1

Product Information Packet EM3611T 3HP,1760RPM,3PH,60HZ,182T,3632M,TEFC,F1 Product Information Packet EM3611T 3HP,1760RPM,3PH,60HZ,182T,3632M,TEFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

Product Information Packet VEM3665T 5HP,1755RPM,3PH,60HZ,184TC,0642M,TEFC,F1

Product Information Packet VEM3665T 5HP,1755RPM,3PH,60HZ,184TC,0642M,TEFC,F1 Product Information Packet VEM3665T 5HP,1755RPM,3PH,60HZ,184TC,0642M,TEFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

Product Information Packet VM HP,1725RPM,3PH,60HZ,56C,3413M,TEFC,F1

Product Information Packet VM HP,1725RPM,3PH,60HZ,56C,3413M,TEFC,F1 Product Information Packet VM3534.33HP,1725RPM,3PH,60HZ,56C,3413M,TEFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

Mod Express Modification Motor Mod Express Page

Mod Express Modification Motor Mod Express Page Page No. Grinders Generators Servo s Education Catalog Index District Offices M1 Balance........................................................................... 324 M1A Dynamic Balance of Rotors M2

More information

FACTORY MODIFICATION PRICING Effective Supercedes

FACTORY MODIFICATION PRICING Effective Supercedes FACTORY MODIFICATION PRICING MODIFICATION LEAD TIME 1. TWMC standard lead time for all modifications is 5-10 working days. If quicker lead time is required, please contact TWMC. Expediting fees may apply.

More information

steel standard SST DUCK components Epoxy Resin Rated Insulation System recognized stainless steel output shaft seal

steel standard SST DUCK components Epoxy Resin Rated Insulation System recognized stainless steel output shaft seal Premium Efficiency Washguard Motors - Now Available! WASHGUARD MOTORS WASHGUARD MOTORS AVAILABLE IN FIVE STYLES Maximum service in critically clean or corrosive environments PREMIUM WASHGUARD ALL-STAINLESS

More information

MAX-E1 HIGH EFFICIENCY. Severe Duty

MAX-E1 HIGH EFFICIENCY. Severe Duty MAX-E1 HIGH EFFICIENCY Severe Duty DESIGN FEATURES & CONSTRUCTION ALL MAX-E1 MOTORS DELIVER THESE IMPRESSIVE DESIGN FEATURES HPE - High Pulse Endurance Wire Non-hygroscopic, Class F insulation system High-grade,

More information

Product Information Packet M1509T 7.5/3.8HP,1740/860RPM,3PH,60HZ,215T,3754

Product Information Packet M1509T 7.5/3.8HP,1740/860RPM,3PH,60HZ,215T,3754 Product Information Packet M1509T 7.5/3.8HP,1740/860RPM,3PH,60HZ,215T,3754 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

Full Load Amps Model Number List 1.52/ / / / / /1.3 4/2 3.6/1.8 4/2 4.4/ / / /2.8 2.

Full Load Amps Model Number List 1.52/ / / / / /1.3 4/2 3.6/1.8 4/2 4.4/ / / /2.8 2. Variable Speed & : VAC, Hz Input Ratings (V/Hz Mode) & Enclosures (V/Hz Mode) Enclosures (Frames 2-445T) (V/Hz Mode) Enclosures (Frames 447-449T) Variable (V/Hz Mode) & Enclosures PowerMatch With All Reliance

More information

DC MOTORS NEMA FRAME SCR RATED

DC MOTORS NEMA FRAME SCR RATED NEMA FRAME SCR RATED NEMA FRAME MOTORS SCR RATED High voltage permanent magnet DC motors are typically used with an SCR (thyristor) controller in applications requiring adjustable speed and constant torque

More information

INDEX NEMA PREMIUM EFFICIENCY

INDEX NEMA PREMIUM EFFICIENCY INDEX S EED EXC DS R TS O DAR MEE E STAN CE THREE-PHASE MOTORS - FEATURES & LIST PRICES THREE-PHASE MOTORS TEFC - Foot-Mount................... A-51 A-54 TEFC C-Flange........................ A-55 ODP

More information

Product Information Packet ECP84400T-4 100HP,1785RPM,3PH,60HZ,405T,A40064M,TEFC

Product Information Packet ECP84400T-4 100HP,1785RPM,3PH,60HZ,405T,A40064M,TEFC Product Information Packet ECP84400T-4 100HP,1785RPM,3PH,60HZ,405T,A40064M,TEFC Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection,

More information

Definite Purpose Motors. Three Phase, Two Speed, TEFC, Foot Mounted. 3/4 thru 25 Hp NEMA 56 thru 324T

Definite Purpose Motors. Three Phase, Two Speed, TEFC, Foot Mounted. 3/4 thru 25 Hp NEMA 56 thru 324T Unit Handling Brake 200 & 575 Volt IEC & Controls DC 158 Two Speed, TEFC, Cast Iron 3/4 thru 25 56 thru 324T Applications: Fans, blowers, machine tools, hoists, conveyors, pumps. Features: Designed for

More information

180VC WITH B5 FLANGE / M ,6 0, / M l 5,0 0,7 192 / M ,0 0,9 223

180VC WITH B5 FLANGE / M ,6 0, / M l 5,0 0,7 192 / M ,0 0,9 223 METRIC (IEC) FRAME THYRISTOR RATED DC METRIC (IEC) FRAME MOTORS IP54 These metric dimensioned motors are built to IEC 34-1 electrical and mechanical standards. The IEC 63 and smaller frames are stocked

More information

Pump Motors. Information. General. Single Phase Motors. Industrial Motors. General Purpose. Severe Duty Motors

Pump Motors. Information. General. Single Phase Motors. Industrial Motors. General Purpose. Severe Duty Motors General Industrial Pump HVAC Farm Duty 8 Pump From industrial wastewater to fire suppression systems or commercial pools, Baldor Reliance pump motors provide value by increasing reliability and reducing

More information

Why Baldor? Baldor Vector Drives in a brick plant in Australia

Why Baldor? Baldor Vector Drives in a brick plant in Australia Why Baldor? For over 80 years, Baldor has been dedicated to providing customers with the best value in energyefficient industrial electric motors and drives. To be considered as the best value supplier

More information

Product Information Packet EM7090T-I 100//75HP,1780//1485RPM,3PH,60//50HZ,405

Product Information Packet EM7090T-I 100//75HP,1780//1485RPM,3PH,60//50HZ,405 Product Information Packet EM7090T-I 100//75HP,1780//1485RPM,3PH,60//50HZ,405 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

SUBMERSIBLES INDEX. General Description and Notes UL Motors Single-Phase UL Approved Three-Phase UL Approved... 4

SUBMERSIBLES INDEX. General Description and Notes UL Motors Single-Phase UL Approved Three-Phase UL Approved... 4 SUBMERSIBLE MOTORS SUBMERSIBLES INDEX SUBMERSIBLE MOTORS General Description and Notes UL Motors...................... 2 Single-Phase UL Approved................................. 2 Three-Phase UL Approved..................................

More information

NEMA & IEC Product Features and Benefits

NEMA & IEC Product Features and Benefits NEMA & IEC Product Features and Benefits BEAUTY BENEATH THE SURFACE. Looking at a Techtop electric motor, it would be understandable if you thought it was just another NEMA or IEC squirrel-cage induction

More information

Explosion Proof Motors

Explosion Proof Motors SINGLE-PHASE Foot Mount...A-110 C-Face Foot Mount...A-110 THREE-PHASE Foot Mount...A-112 C-Face Foot Mount...A-116 C-Face Footless...A-117 JP Foot Mount...A-117 ATEX Foot Mount...A-120 A-108 Fractional

More information

Baldor Mod Express Modification Motor Mod Express Page

Baldor Mod Express Modification Motor Mod Express Page Page No. ATEX M1 Balance... 396 M1A Dynamic Balance of Rotors M2 Bearings... 396 M2A Sealed or Double Shielded M2B Ball to Roller M2C Bearing Thermocouples M2D Bearing RTD S M2E Add Double Sealed Bearings

More information

Product Information Packet ECP4410T-4 125HP,1785RPM,3PH,60HZ,444T,A44076M,TEFC

Product Information Packet ECP4410T-4 125HP,1785RPM,3PH,60HZ,444T,A44076M,TEFC Product Information Packet ECP440T-4 5HP,785RPM,3PH,60HZ,444T,A44076M,TEFC Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

Product Information Packet ECP4406T-4 150HP,1785RPM,3PH,60HZ,445T,A4488M,TEFC

Product Information Packet ECP4406T-4 150HP,1785RPM,3PH,60HZ,445T,A4488M,TEFC Product Information Packet ECP4406T-4 150HP,1785RPM,3PH,60HZ,445T,A4488M,TEFC Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

Product Information Packet EM4313T 75HP,3550RPM,3PH,60HZ,365TS,1464M,TEFC,F

Product Information Packet EM4313T 75HP,3550RPM,3PH,60HZ,365TS,1464M,TEFC,F Product Information Packet EM1T 75HP,550RPM,PH,60HZ,65TS,16M,TEFC,F Copyright All product information within this document is subject to A Motors and Mechanical Inc. copyright protection, unless otherwise

More information

AutomationDirect AC Motors Selection Overview

AutomationDirect AC Motors Selection Overview AutomationDirect AC s Selection (1992), High, What does it all mean? In 1992, the U.S. Congress passed legislation requiring that general purpose Design A & B motors meet minimum efficiency requirements,

More information

Medium Voltage Motors and Soft Starters

Medium Voltage Motors and Soft Starters TEFC Severe Duty Motors TEFC Motors 2300 4160V................................................. A-252 TEFC Motors Add-On Modifications............................................. A-253 TEFC 2300V - Electrical

More information

Product Information Packet ECP84404T-4 75HP,1185RPM,3PH,60HZ,405T,A4072M,TEFC,F

Product Information Packet ECP84404T-4 75HP,1185RPM,3PH,60HZ,405T,A4072M,TEFC,F Product Information Packet ECP84404T-4 75HP,1185RPM,3PH,60HZ,405T,A4072M,TEFC,F Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection,

More information

Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200 volt power.

Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200 volt power. 200 Volt, TEFC, Foot Mounted 1/2 thru 0 200 & 7 Volt 6C thru 26T Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200 volt power. Features:

More information

Product Information Packet ZDVSM4406T-4 150HP, RPM,3PH,60-90HZ,444T,A440

Product Information Packet ZDVSM4406T-4 150HP, RPM,3PH,60-90HZ,444T,A440 Product Information Packet ZDVSM4406T-4 150HP,1790-2685RPM,3PH,60-90HZ,444T,A440 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection,

More information

Product Information Packet EM7064T-I 50//40HP,1775//1475RPM,3PH,60//50HZ,326T

Product Information Packet EM7064T-I 50//40HP,1775//1475RPM,3PH,60//50HZ,326T Product Information Packet EM7064T-I 50//40HP,1775//1475RPM,3PH,60//50HZ,326T Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

SHADED RATINGS ARE CAST IRON FRAMES

SHADED RATINGS ARE CAST IRON FRAMES Gearmotors and NEMA AC C-Face Kits for Field Conversion Features: Complete kits with all hardware necessary for converting 56 through 445T frame rigid base motors to C-Face mounting with base. For a conversion,

More information

Product Information Packet ECP84314T-4 60HP,1780RPM,3PH,60HZ,364T,TEFC,FOOT

Product Information Packet ECP84314T-4 60HP,1780RPM,3PH,60HZ,364T,TEFC,FOOT Product Information Packet ECP84314T-4 60HP,1780RPM,3PH,60HZ,364T,TEFC,FOOT Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

Quick and Easy Voltage Flexibility for NEMA and Metric IEC Motors Motors are re-rated from stock models to 575V in as little as (1) business day

Quick and Easy Voltage Flexibility for NEMA and Metric IEC Motors Motors are re-rated from stock models to 575V in as little as (1) business day Elektrim 7V s Quick and Easy Voltage Flexibility for NEMA and Metric IEC s s are re-rated from stock models to 7V in as little as () business day Available 7V s: -0 HP NEMA Premium Performance Series s

More information

A Full Line of Low Voltage IEC Motors In-Stock

A Full Line of Low Voltage IEC Motors In-Stock BUILT TO PERFORM WHERE OTHERS FAIL A Full Line of Low Voltage IEC Motors In-Stock Distributed by Elektrim Motors Authorized Distributor: www.elektrimmotors.com or call 855-Go-Elektrim 0.08-220HP Low Voltage

More information

Product Information Packet EM4110T 40HP,1775RPM,3PH,60HZ,324T,1254M,TEFC,F1

Product Information Packet EM4110T 40HP,1775RPM,3PH,60HZ,324T,1254M,TEFC,F1 Product Information Packet EM4110T 40HP,1775RPM,3PH,60HZ,324T,1254M,TEFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

Product Information Packet IDNM2238T 10HP,1770RPM,3PH,60HZ,256TC,0948M,TENV

Product Information Packet IDNM2238T 10HP,1770RPM,3PH,60HZ,256TC,0948M,TENV Product Information Packet IDNM2238T 10HP,1770RPM,3PH,60HZ,256TC,0948M,TENV Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

SEWPCC UPGRADING/EXPANSION PROJECT BID OPPORTUNITY SECTION LOW-VOLTAGE AC INDUCTION MOTORS

SEWPCC UPGRADING/EXPANSION PROJECT BID OPPORTUNITY SECTION LOW-VOLTAGE AC INDUCTION MOTORS SECTION 26 20 00 LOW-VOLTAGE AC INDUCTION MOTORS SEWPCC UPGRADING/EXPANSION PROJECT PART 1 GENERAL 1.1 RELATED SECTIONS A. This section applies only when referenced by a motor-driven equipment specification.

More information

Product Information Packet EM7082T-I 25//20HP,1180//985RPM,3PH,60//50HZ,324T

Product Information Packet EM7082T-I 25//20HP,1180//985RPM,3PH,60//50HZ,324T Product Information Packet EM7082T-I 25//20HP,1180//985RPM,3PH,60//50HZ,324T Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

The Best Value in Washdown Duty Motors and Drives

The Best Value in Washdown Duty Motors and Drives The Best Value in Washdown Duty Motors and Drives Long before we invested in the people, equipment and material required to produce Baldor Reliance Washdown Duty motors and drives, we invested our time

More information

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents. PART 1: GENERAL 1.01 This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is to apply the

More information

Product Information Packet EM4104T 30HP,1760RPM,3PH,60HZ,286T,1056M,TEFC,F1

Product Information Packet EM4104T 30HP,1760RPM,3PH,60HZ,286T,1056M,TEFC,F1 Product Information Packet EM4104T 30HP,1760RPM,3PH,60HZ,286T,1056M,TEFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

Understanding NEMA Motor Nameplates

Understanding NEMA Motor Nameplates Understanding NEMA Motor Nameplates Mission Statement is to be the best (as determined by our customers) marketers, designers and manufacturers of industrial electric motors, mechanical power transmission

More information

Design Standard. Electric Motors. Detailed specifications follow. PART 1 - GENERAL

Design Standard. Electric Motors. Detailed specifications follow. PART 1 - GENERAL Design Standard Detailed specifications follow. PART 1 - GENERAL 1.01 SCOPE This design guidelines contained herein include the requirements of electric motors utilized for electric motor driven systems

More information

NEMA D Flange Kits -LEESON Motors Only. Motor Accessories -Field Installed Steel and Cast Iron Frame Motors

NEMA D Flange Kits -LEESON Motors Only. Motor Accessories -Field Installed Steel and Cast Iron Frame Motors IEC Motors NEMA D Flange Kits -LEESON Motors Only Motor Accessories -Field Installed Steel and Cast Iron Frame Motors DC Motors Includes parts to convert arigid base mounted motor to NEMA Dface with base.

More information

NEMA AC Motor C-Face Kits for Field Conversion

NEMA AC Motor C-Face Kits for Field Conversion Gear s NEMA AC C-Face Kits for Field Conversion Features: Complete kits with all hardware necessary for converting Baldor 56 through 445T frame rigid base motors to C-Face mounting with base. For a Baldor

More information

7.0 High HP Low and Medium Voltage

7.0 High HP Low and Medium Voltage TABLE OF CONTENTS 7.0 High HP Low and 7.1 Quantum LMV - TEFC Low Voltage 7.7 Quantum LMV - TEFC 7.12 449 Frame TEFC 7.16 WPII, TEFC, TEAAC Standard Features 7.17 WPII Pricing and Kits 7.20 Pegasus MHV

More information

Product Information Packet M HP,1425RPM,3PH,50HZ,56,3420M,TEFC,F1

Product Information Packet M HP,1425RPM,3PH,50HZ,56,3420M,TEFC,F1 Product Information Packet M3538-50.5HP,1425RPM,3PH,50HZ,56,3420M,TEFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

Product Information Packet EM3558T-57 2HP,1445RPM,3PH,50HZ,145T,3528M,TEFC,F1

Product Information Packet EM3558T-57 2HP,1445RPM,3PH,50HZ,145T,3528M,TEFC,F1 Product Information Packet EM3558T-57 2HP,1445RPM,3PH,50HZ,145T,3528M,TEFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

SUPER-MAX INDUCTION MOTOR

SUPER-MAX INDUCTION MOTOR Compliance Certificate No.CC014A CSA Listed No. 1077944 SUPER-MAX INDUCTION MOTOR PREMIUM EFFICIENCY SERIES CSA Certified for Class I Division 2 Groups A, B, C, D T3C TOTALLY ENCLOSED FAN COOLED FRAME:

More information

Product Information Packet ZDVSM2334T 20HP,1770RPM,3PH,60HZ,256TC,0960M,TEFC,F

Product Information Packet ZDVSM2334T 20HP,1770RPM,3PH,60HZ,256TC,0960M,TEFC,F Product Information Packet ZDVSM2334T 20HP,1770RPM,3PH,60HZ,256TC,0960M,TEFC,F Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection,

More information

Product Information Packet CEM7064T-I 50//40HP,1775//1475RPM,3PH,60//50HZ,326T

Product Information Packet CEM7064T-I 50//40HP,1775//1475RPM,3PH,60//50HZ,326T Product Information Packet CEM7064T-I 50//40HP,1775//1475RPM,3PH,60//50HZ,326T Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection,

More information

A. Fan motors and associated equipment shall be sized to operate at 110% of calculated loads and capacities.

A. Fan motors and associated equipment shall be sized to operate at 110% of calculated loads and capacities. PART 1: GENERAL 1.01 This design guidelines contained herein includes the requirements electric motors utilized for electric motor driven systems at Texas State University. It is the intention of this

More information

CM7059T 20/15HP,3515/2920RPM,3PH,60/50HZ,256TC

CM7059T 20/15HP,3515/2920RPM,3PH,60/50HZ,256TC Product Information Packet CM7059T 20/15HP,3515/2920RPM,3PH,60/50HZ,256TC Copyright All product information within this document is subject to Baldor Electric Company copyright protection, unless otherwise

More information

Product Information Packet ECP44206TR-4 200HP,1190RPM,3PH,60HZ,449T,A44160M,TEFC

Product Information Packet ECP44206TR-4 200HP,1190RPM,3PH,60HZ,449T,A44160M,TEFC Product Information Packet ECP44206TR-4 200HP,1190RPM,3PH,60HZ,449T,A44160M,TEFC Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection,

More information

Product Information Packet EM3613T 5HP,3450RPM,3PH,60HZ,184T,3630M,TEFC,F1

Product Information Packet EM3613T 5HP,3450RPM,3PH,60HZ,184T,3630M,TEFC,F1 Product Information Packet EM3613T 5HP,3450RPM,3PH,60HZ,184T,3630M,TEFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

200 & 575 Volt Motors. 200 Volt, Three Phase, TEFC, Foot Mounted. 1/2 thru 50 Hp NEMA 56C thru 326T

200 & 575 Volt Motors. 200 Volt, Three Phase, TEFC, Foot Mounted. 1/2 thru 50 Hp NEMA 56C thru 326T Farm Duty 200 Volt, TEFC, Foot Mounted 200 & 7 Volt 1/2 thru 0 6C thru 26T Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200 volt power.

More information

IDNM3581T 1HP,1745RPM,3PH,60HZ,143TC,0524M,TENV,F1

IDNM3581T 1HP,1745RPM,3PH,60HZ,143TC,0524M,TENV,F1 Product Information Packet IDNM3581T 1HP,1745RPM,3PH,60HZ,143TC,0524M,TENV,F1 Copyright All product information within this document is subject to Baldor Electric Company copyright protection, unless otherwise

More information

Product Information Packet IDM4316T 75HP,1780RPM,3PH,60HZ,365T,1482M,TEBC,F1

Product Information Packet IDM4316T 75HP,1780RPM,3PH,60HZ,365T,1482M,TEBC,F1 Product Information Packet IDM4316T 75HP,1780RPM,3PH,60HZ,365T,1482M,TEBC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

Product Information Packet EM4107T 25HP,3520RPM,3PH,60HZ,284TS,0944M,TEFC,F

Product Information Packet EM4107T 25HP,3520RPM,3PH,60HZ,284TS,0944M,TEFC,F Product Information Packet EM4107T 25HP,3520RPM,3PH,60HZ,284TS,0944M,TEFC,F Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

W22 Medium Voltage Motors TEFC - Severe Duty

W22 Medium Voltage Motors TEFC - Severe Duty 101 www.pamensky.com W22 Medium Voltage Motors TEFC - Severe Duty Standard Features Three-phase, 2, 4, 6 and 8 pole, 60Hz Voltage: 1200V, 2300V, 2400V, 3300V, 4000V, 4160V & 6600V Totally Enclosed Fan

More information

SB380. Sept Rev. A

SB380. Sept Rev. A SB380 Sept. 2010 Rev. A Features pertaining to stock line ODP TEFC C-Face CCP Power range (stock) 1 1/2-200HP 1 1/2-200HP 1 1/2-100HP 1-50HP Frame construction (Rolled Steel) 180-210 N/A 180-210 140-210

More information

EPACT ENERGY POLICY ACT OF 1992: THE SCOPE OF ELECTRIC MOTORS SUBJECT TO EFFICIENCY STANDARDS ON OCTOBER

EPACT ENERGY POLICY ACT OF 1992: THE SCOPE OF ELECTRIC MOTORS SUBJECT TO EFFICIENCY STANDARDS ON OCTOBER EPACT ENERGY POLICY OF 1992: THE SCOPE OF ELECTRIC MOTORS SUBJECT TO EFFICIENCY STANDARDS ON OCTOBER 24, 1997 The Energy Policy Act of 1992 (EPAct) covering efficiency levels of general purpose industrial

More information

Product Information Packet CEM3587T 2HP,1750RPM,3PH,60HZ,145TC,0527M,TEFC,F1

Product Information Packet CEM3587T 2HP,1750RPM,3PH,60HZ,145TC,0527M,TEFC,F1 Product Information Packet CEM3587T 2HP,1750RPM,3PH,60HZ,145TC,0527M,TEFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

Definite Purpose Motors. Three Phase, Two Speed, TEFC, Foot Mounted. Applications: Fans, blowers, machine tools, hoists, conveyors, pumps.

Definite Purpose Motors. Three Phase, Two Speed, TEFC, Foot Mounted. Applications: Fans, blowers, machine tools, hoists, conveyors, pumps. Three Phase, Two Speed, TEFC, 1 thru 25 56 thru 324T Applications: Fans, blowers, machine tools, hoists, conveyors, pumps. Features: Lifting eye bolt mounted at top center 215T frame and larger for easy

More information

: B3; B5; B14; B34; B35; V1

: B3; B5; B14; B34; B35; V1 ATT WE series (Eff1) are 3-phase TEFC Cast-Iron high efficiency general purpose induction motors, which are designed to meet or exceed the requirements for energy efficiency such as: European Eff1, Australia

More information

Powerful + Efficient + Reliable

Powerful + Efficient + Reliable 1 THRU 50HP NEMA 140T THRU 449T HIGH EFFICIENCY ISO9001 CERTIFIED Powerful + Efficient + Reliable TEFC CAST IRON FRAMES CLASS F INSULATED 1.15 SERVICE FACTOR OVER SIZED BEARINGS LOW-LOSS ELECTRICAL GRADE

More information

EM7066T 50/60HP,1475/1780RPM,3PH,50/60HZ,364T

EM7066T 50/60HP,1475/1780RPM,3PH,50/60HZ,364T Product Information Packet EM7066T 50/60HP,1475/1780RPM,3PH,50/60HZ,364T Copyright All product information within this document is subject to Baldor Electric Company copyright protection, unless otherwise

More information

Product Information Packet IDNM3587T 2HP,1755RPM,3PH,60HZ,145TC,0535M,TENV,F1

Product Information Packet IDNM3587T 2HP,1755RPM,3PH,60HZ,145TC,0535M,TENV,F1 Product Information Packet IDNM3587T 2HP,1755RPM,3PH,60HZ,145TC,0535M,TENV,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

Product Information Packet HM9218T 2HP,1755RPM,3PH,60HZ,145T,3523M,OPSB,F1

Product Information Packet HM9218T 2HP,1755RPM,3PH,60HZ,145T,3523M,OPSB,F1 Product Information Packet HM9218T 2HP,1755RPM,3PH,60HZ,145T,3523M,OPSB,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

Product Information Packet EMVM3546D .75KW,1760RPM,3PH,60HZ,D80D,3520M,TEFC,B

Product Information Packet EMVM3546D .75KW,1760RPM,3PH,60HZ,D80D,3520M,TEFC,B Product Information Packet EMVM3546D.75KW,1760RPM,3PH,60HZ,D80D,3520M,TEFC,B Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

Product Information Packet EM4109T 40HP,3530RPM,3PH,60HZ,324TS,1058M,TEFC,F

Product Information Packet EM4109T 40HP,3530RPM,3PH,60HZ,324TS,1058M,TEFC,F Product Information Packet EM4109T 40HP,3530RPM,3PH,60HZ,324TS,1058M,TEFC,F Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

Product Information Packet CP500808LR-4 800HP,897RPM,3PH,60HZ,G50,A95260M,TEFC,F

Product Information Packet CP500808LR-4 800HP,897RPM,3PH,60HZ,G50,A95260M,TEFC,F Product Information Packet CP500808LR-4 800HP,897RPM,3PH,60HZ,G50,A95260M,TEFC,F Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection,

More information

M3613T 5HP,3460RPM,3PH,60HZ,184T,3626M,TEFC,F1

M3613T 5HP,3460RPM,3PH,60HZ,184T,3626M,TEFC,F1 Product Information Packet M3613T 5HP,3460RPM,3PH,60HZ,184T,3626M,TEFC,F1 Copyright All product information within this document is subject to Baldor Electric Company copyright protection, unless otherwise

More information

Features and Benefits

Features and Benefits Features and Benefits ELECTRICAL DESIN z 1 500 HP; 2, 4, 6 pole z 3600, 1800, 1200 RPM z 3 Phase, 60 Hz, 460V z Motors can be rerated for 380, 400 and 415 VAC at 50 Hz. z Designed to meet NEMA M1, M13,

More information

SUBMERSIBLE PUMPS DRAINER SUMP/EFFLUENT

SUBMERSIBLE PUMPS DRAINER SUMP/EFFLUENT SUBMERSIBLE PUMPS DRAINER SUMP/EFFLUENT LEESON Canada features products by well known manufacturer Berkeley which includes the Toran and Simer brand names. SUBMERSIBLE UTILITY PUMPS GEYSER II 1/6 HP 1/6

More information