RPMAC Inverter Duty Motors Stock Model Number Cross Reference List

Size: px
Start display at page:

Download "RPMAC Inverter Duty Motors Stock Model Number Cross Reference List"

Transcription

1 RPMAC Inverter Duty Motors Stock Model Cross Reference List L180 to RL210 Functional Replacement The following RL210 frames are intended to be only functional replacements of the L180 RPMAC frames, which have been discontinued. We have upgraded this part of our product line so that we can offer a complete laminated steel frame from 2 HP through 1000 HP. The RL210 is not mechanically interchangeable with the L180 since it is a 210 frame. However, if the L180 was a flange mounted motor, then the RL210 will have the same NEMA C-face and shaft as the original L180 TC frame. The RL210 frame motors will typically provide the same continuous and overload torques as the L180 overload torque provided. However, the inertia of Rl210 frames is greater than L180 frames. For a lower inertia option that will more closely match the inertia of the L180 frames, please see data for frames designated ARL210 series. HP Base Speed C. HP Speed Voltage Enclosure Old Frame Old Model New Frame New Model Mounting Dimension Sheet TENV L1831 P18L275 RL2153 P21R335 Foot TENV L1831 P18L276 RL2153 P21R336 Foot TENV L1831 P18L277 RL2153 P21R337 Foot TENV L1831 P18L279 RL2153 P21R338 Foot TENV L1838 P18L280 RL2153 P21R339 Foot TENV L1844 P18L281 RL2153 P21R340 Foot TENV NEW NEW RL2153 P21R341 Foot TENV L1831 P18L283 RL2153 P21R386 Foot /460 TENV L1831C P18L261 RL2153C P21R307 FT/ (180TC) /460 TENV L1831C P18L332(#) RL2153C P21R373(#) FT/ (180TC) TENV L1838 P18L284 RL2158 P21R342 Foot TENV L1852 P18L285 RL2162 P21R343 Foot TEBC L1838 P18L286 RL2153 P21R344 Foot TEBC L1838 P18L287 RL2153 P21R345 Foot TENV L1838 P18L288 RL2153 P21R346 Foot TENV L1838 P18L269 RL2153 P21R387 Foot /460 TENV L1844C P18L262 RL2158C P21R308 FT/ (210TC) /460 TENV L1844C P18L263(@) RL2158C P21R374(@) FT/ (210TC) /460 TENV L1844C P18L333(#) RL2158C P21R375(#) FT/ (210TC) /460 TENV L1852 P18L290 RL2162 P21R347 Foot TEBC L1838 P18L291 RL2153 P21R348 Foot TEFC L1852 P18L339 RL2158 P21R382 Foot TEBC L1844 P18L293 RL2153 P21R333 Foot TEBC L1852 P18L295 RL2158 P21R349 Foot /460 TENV L1844 P18L296 RL2158 P21R320 Foot TENV L1844 P18L297 RL2158 P21R350 Foot /460 TENV L1852C P18L264 RL2162C P21R309 FT/ (210TC) /460 TENV L1852C P18L265(@) RL2162C P21R376(@) FT/ (210TC) /460 TENV L1852C P18L334(#) RL2162C P21R377(#) FT/ (210TC) TEFC L1852 P18L340 RL2162 P21R329 Foot TEBC L1844 P18L298 RL2153 P21R351 Foot DPG-FV L1844 P18L299 RL2153 P21R371 Foot TEBC L1852 P18L300 RL2158 P21R383 Foot DPG-FV L1852 P18L301 RL2158 P21R352 Foot (#) -Includes BEI HS35 encoder (@) - Includes Dynapar H20 encoder M-183

2 Large AC RPMAC Inverter Duty Motors Stock Model Cross Reference List L180 to RL210 Functional Replacement RPM III Medium DC Motors RPM XL Small DC Motors RPM AC Inverter Duty Inverter Duty AC Motors HP Base Speed C. HP Speed Voltage Enclosure Old Frame Old Model New Frame New Model Mounting Dimension Sheet DPG-FV L1838 P18L302 RL2153 P21R353 Foot TEBC L1838 P18L304 RL2153 P21R354 Foot /460 TENV L1852 P18L303 RL2162 P21R330 Foot DPG-FV L1838 P18L305 RL2153 P21R355 Foot TEBC L1838 P18L306 RL2153 P21R356 Foot DPG-FV L1838 P18L307 RL2153 P21R357 Foot TEFC L1852C P18L266 RL2158C P21R358 FT/ (250TC) TEFC L1852C RL2158C FT/ (250TC) TEFC L1852C P18L335(#) RL2158C P21R379(#) FT/ (250TC) TEBC L1844 P18L325 RL2153 P21R359 Foot DPG-FV L1844 P18L308 RL2153 P21R372 Foot TEBC L1852 P18L309 RL2162 P21R360 Foot DPG-FV L1852 P18L310 RL2158 P21R361 Foot DPG-FV L1838 P18L317 RL2153 P21R363 Foot TEBC L1838 P18L318 RL2153 P21R323 Foot DPG-FV L1838 P18L319 RL2153 P21R362 Foot TEFC L1852 P18L338 RL2158 P21R384 Foot TEBC L1844 P18L320 RL2158 P21R364 Foot DPG-FV L1838C P18L328 RL2153C P21R365 FT/ (250TC) TEBC L1852C P18L268 RL2158C P21R314 FT/ (250TC) TEBC L1852C RL2158C FT/ (250TC) TEBC L1852C P18L336(#) RL2158C P21R381(#) FT/ (250TC) DPG-FV L1852C P18L329 RL2158C P21R315 FT/ (250TC) DPG-FV L1838 P18L321 RL2153 P21R366 Foot TEBC L1844 P18L322 RL2158 P21R331 Foot DPG-FV L1838 P18L323 RL2153 P21R367 Foot TEBC L1852 P18L324 RL2162 P21R385 Foot DPG-FV L1844C P18L330 RL2158C P21R368 FT/(250TC) DPG-FV L1838 P18L311 RL2153 P21R317 Foot TEBC L1852 P18L312 RL2162 P21R328 Foot DPG-FV L1844 P18L313 RL2153 P21R369 Foot DPG-FV L1852C P18L331 RL2158C P21R327 FT/ (250TC) DPG-FV L1844 P18L314 RL2158 P21R324 Foot DPG-FV L1852 P18L315 RL2158 P21R370 Foot DPG-FV L1852 P18L316 RL2162 P21R325 Foot (#) -Includes BEI HS35 encoder - Includes Dynapar H20 encoder General Information For pricing information or to place orders, go to M-184

3 RPM AC INTEGRAL HP INVERTER DUTY MOTORS GENERAL INFORMATION GENERAL FEATURES UNIQUE SQUARE LAMINATED STEEL FRAME RPM AC motors are designed specifically for optimum inverter duty performance. From three generations of successful experience with laminated frame DC motors, RPM AC motors have been designed as square, laminated steel frame (RL210 - L440 NEMA & RDL132-DL280 IEC) to achieve maximum performance on inverter power. RPM AC customer benefits: Most cost effective solutions in the industry Square frame designs allow larger horsepower ratings in smaller frame sizes than NEMA cast iron motors without compromise in performance or life Stock availability from 1/ HP Replace larger frame NEMA AC and DC motors easily 1000:1 constant torque in vector mode is standard on DPFV, TENV, TEBC and TEFC as shown in catalog. Feet located on cast iron brackets provide more rigid, vibrationresistant structure. Rugged laminated steel frames Wide constant horsepower range - 4:1 to 12:1 available High peak torque- 200% standard on enclosed motors; 300% to 400% available upon request Low inertia for fast acceleration Mount multiple accessories easily - encoders, brakes Encoder provisions: machined opposite drive end bracket and tapped shaft for addition of stub shaft are standard on DPFV, TENV and TEBC; a tapped shaft only is standard for TEFC for ease of mounting HS35 hollow shaft encoders. TEFC 1000:1 Constant Torque RL2173 Frame Typical Applications RPM AC motors have been successfully applied on a wide variety of applications. Because of the versatility to meet both wide constant torque and constant HP needs, optimum power matched solutions are available for the following: Constant Torque: Extruders, injection molding, conveyors, paper machines, crane and hoist. Includes web processing on printing press, metal coating, film and paper coating. Cut-to -length applications on shears used in metals and paper corrugators utilize the low inertia and mechanical ruggedness of laminated frame RPM AC Constant Horsepower: Winders, unwinders, recoilers, tension reels, and machine tool spindle are examples where high peak torque to inertia for fast acceleration, and constant HP ranges of 4:1 up to 16:1 have been supplied. The ability to design very low base speeds and high response are standard with RPM AC. High shock and Vibration: Stamping presses for automotive and metal stamping take advantage of compact designs with feet on the brackets directly under the bearings. Includes high horsepower top drives for off shore oil rigs with the added demands of high humidity, salt spray and extreme ambient conditions. Test stands: Again, the fast response and compact mechanical features of RPM AC make it the choice solution for test stand applications. Depending on frame size, maximum speeds of RPM are available. Variable Torque Loads: Because of the economic advantages and compactness of RPM AC motors, many customers have selected DPFV RPM AC for many variable torque applications, particularly for high horsepower requirements. M-185

4 Inverter Duty AC Motors RPM AC Inverter Duty RPM XL Small DC Motors Large AC APPLICATION TOOLS The RPMAC MOTOR WIZARD is a patented, revolutionary inverter duty motor selection program. For custom motor requirements not found in the catalog, the WIZARD allows you to input exact values of altitude, ambient, base speed, wide constant HP speed ranges, enclosure, voltage, continuous torque and overload torque. The output includes: motor frame size, inverter kva, and typical motor amps. It allows evaluation of lower cost alternatives based on your needs. You can immediately print typical performance data curves, motor, conduit box and encoder typical dimensions. A DUTY CYCLE CALCULATOR is included in the RPM AC Motor Wizard to determine the motor frame size for load torques which vary cyclically over time. The RPMAC MOTOR WIZARD CD can be ordered from Rockwell Automation, ordering number RAPS-517, through your Rockwell Automation contact. It can also be downloaded from the web at www. reliance.com. We encourage customer use of this powerful tool to aid in rapid selection of the exact motor for your application needs BASIS OF RATINGS The RPM AC motors in this catalog are designed specifically for use on IGBT voltage source controllers (PWM and six step VVI). Motor characteristics are optimized to reduce peak currents from the controller as well as to minimize motor losses. When the AC controller is properly adjusted, RPM AC motor performance will be in accordance with published rating data. The ratings in this catalog are based on a minimum PWM frequency of 4 khz for HP through 500, 2 khz for 600 HP and higher, and a minimum ratio of PWM frequency: fundamental frequency of 20:1. Totally Enclosed Blower Cooled With Mounted Encoder VOLTAGE SPIKE CAPABILITY CORONA-FREE DESIGNS dv/dt and peak voltages) RPM AC insulation systems have been tested extensively to insure successful operation on inverter waveshapes, including fast switching IGBTs. All motors are designed to withstand high peak voltages caused by the combination of long lead lengths and steep voltage wavefronts, with no corona formation, for AC input voltages up to 575 volts RMS. Consult the control manufacturer for specific lead length recommendations. All RPM AC motors have been designed to surpass the requirements of NEMA MG , Part 31, Section 4 for definite purpose, inverter fed, polyphase motors for voltage spikes. All RPM AC motors for base voltage rating of 460 volts and below have been qualified by test to meet a minimum of 1600 volts peak, and a dv/dt in excess of 10,000 volts per microsecond. For voltages above 460 volts, including 575 volts, motors use an insulation system which is qualified by test to meet minimum peak voltages of 1850 volts and dv/dt in excess of 10,000 volts per microsecond rate of rise. RPM III Medium DC Motors General Information For pricing information or to place orders, go to M-186

5 STANDARD MOTOR FEATURES AGENCY LISTINGS AND CERTIFICATIONS RL210 through L440 Frame ORDINARY LOCATIONS All RPM AC motors are eligible for UL component listing and CSA Certification for Ordinary s for all enclosures. (Please note blower changes on certain TEBC Stock Ratings below for UL listing.) On stock motors, the CSA mark for ordinary locations on all RPM AC motors in frames RL210 - L440 (all enclosures), and UL logo in TEBC frames L360 - L440 is standard. Both the CSA CSA file number LR40567 mark and UL logo are standard on stock DPFV and TEFC models in frames RL210 - L440, and all TENV stock models. The CSA mark and UL logo can be supplied on all production motors. The UL logo can be obtained on stock TEBC RL210 - L320 by requesting the 56 frame blower package at no extra charge. Motor dimensions will change with 56 frame blower. All RPM AC IEC frame motors include the CE mark as standard. The CE mark can be supplied on any motor, NEMA or IEC frame, but must be requested at time of order entry for NEMA frames, both stock and production. IMPORTANT Motors with modifications or accessories not approved by UL or CSA may not have the agency logo stamped on the nameplate CLASSIFIED AREAS - HAZARDOUS LOCATIONS Class 1 Division 2 Certification Inverter Duty RPM AC * RPM AC motors have been tested and certified by CSA for operation on inverter power in areas classified as Class 1, Groups A, B, C and D, Division 2 for all TENV, TEBC, TEFC and DPFV CSA file number LR46877 enclosures. See Pricing and Modifications sections of catalog. Motor frame size will vary based on the NEC temperature code specified. Contact Rockwell Automation Sales Engineers representing DODGE and Reliance Electric brands of products for details. NOTE: Accessories supplied and mounted on the motor must be approved for Class 1, Division 1 or 2 and the same groups as main motor. This will limit the availability of some modifications. See available modifications in this catalog for further details. * Groups A and B not available on TEBC Enclosure Class 1 Division 1 RPM AC motors have been tested and approved by CSA for Class 1 Division 1 or 2 locations for Totally Enclosed Pipe In/ Pipe Out Ventilation - see Application section for details. For UL listed Division 1 explosion proof motors for inverter duty, see Variable Speed catalog. ALTITUDE - AMBIENT All motors in this catalog are based on 40 degrees C ambient, altitude of 3300 feet (1000 meters) above sea level at 1.0 service factor on inverter power. All motors are suitable for low ambient down to -25C as standard. Modifications can be selected for service factor, ambient and altitude as needed from the modification section. ADJUSTABLE SPEED CAPABILITY All RPM AC motors in this catalog are rated Vector Duty, in that they are capable of 1000:1 constant torque below base speed. They are suitable for full load torque continuously at zero speed. RPM AC motors may be applied to inverters that are configured for vector control with encoder (flux regulated vector), sensor less vector, or scalar (volts per hertz operation). The constant torque speed range obtained is dependent on the control s ability to properly regulate the motor flux. For example, continuous torque at zero speed may require a vector control with encoder feedback, depending on the specific performance requirements, including overloads and transient response Enclosure Below Base Speed Constant Torque (1) Speed Range Above Base Speed Constant Horsepower TEBC 1000:1 2:1 (2) TENV 1000:1 2:1 (2) TEFC 1000:1 2:1 (2) DPFV 1000:1 AS PUBLISHED (1) suitable for Full Torque down to zero speed continuously on Vector controllers on which motor flux is regulated (2) See price section and Application Data for speed limitations TEFC 1000:1 Constant Torque 25 HP 1750 RPM M-187

6 RPM III Medium DC Motors RPM XL Small DC Motors RPM AC Inverter Duty Inverter Duty AC Motors Large AC OPTIMIZED FOUR & SIX POLE DESIGNS The ratings in this catalog are based on the use of four pole laminations in frames RL210 thru L400, and six pole in L440 frame, for adjustable frequency service. By designing the motor for rated voltage at the desired base speed, motor current and therefore controller size can be minimized. The base speed is obtained by adjusting the controller frequency as required. For example, with four poles, a base speed of 1750 RPM at 460 volts would require a 60 Hz nominal controller output frequency at 460 volts. A base speed of 850 RPM would require a 30 Hz frequency setting at 460 volts output. Using this approach, motors of the same horsepower with different base speeds will have the same nominal full load current even though frame sizes will change. Motor designs are optimized for the exact base speed and not derated or overframed. NOTE: RPM AC motors are optimized for inverter power supplies. Contact Reliance Electric if by-pass mode (across-the-line) is required. BALANCE Standard - All RPM AC motors meet the dynamic balance limits of NEMA MG1 Part 7 for peak value of the unfiltered velocity in inches per second as shown below: Standard Balance Limits RPM RL210 - L440 Velocity (inches / sec) Peak Per NEMA Standard See Modification section for higher grade balance (Ultra Standard and Precision) and NEMA Standard in Table 1 in Modification Section. BEARING - INSULATED All RPM AC L440 frames include insulated opposite drive end bearing as standard. BEARINGS - LUBRICATION Standard - All RPM AC motors use deep-grooved anti-friction ball bearings. Oversized ball bearings are standard on frames RL210 through RL250 for both coupled and belted duty. Roller bearings are used for belted duty on frames UL280 through UL440. These bearings and their internal clearances have been especially selected based on load carrying ability, thermal stresses and speed range consistent with ample bearing life. Double shielded bearings with oversize grease reservoirs that provide lifetime lubrication with no maintenance are standard on RL210-RL250 frames; bearings in frames RL210 & RL250 are not regreasable. Exclusive PLS lubrication incorporating open bearings with inner caps is standard on L280-L440 frames. See the Application Section for bearing life data. CONDUIT BOX (TERMINAL HOUSING) Standard construction for frames RL210 through L360 provides a gasketed, stamped steel box and cover. Boxes can be rotated in 90 degree increments, and located in any quadrant as long as accessories are not in the same quadrant. Standard construction for frames L400 and L440 are heavy gauge mill type conduit boxes which can be mounted on either side or the top of the motor as long as not in the same quadrant as the blower. See the Modification Section for location and construction options. Standard Conduit Box For All Frames, Including Stock Models Frame Enclosure Terminal Blocks RL210 - L400 L440 TENV / TEBC Top (F-3) Option DPG-FV F-1 Option TEAO-P/B F-1 Option DPG-FV F-1 Option For XT, Outdoor, or Paper Mill Duty, cast iron boxes are standard in frames RL210-L360. A large mill box is standard on L400 designs and all L440 frames. Other conduit box locations available on stock RL210-L440 and production. See modification section. CONNECTIONS Motor power leads and thermostat leads are terminated in the conduit box and have sufficient length (approximately 6 inches) for connecting to the power leads. DIRECTION OF ROTATION All RPMAC motors are designed for bi-directional rotation. All motors are phase sequenced so that when voltages in an A-B-C phase sequence are applied to leads U/T1, V/T2, W/T3 clockwise shaft rotation facing the opposite drive end will occur. ENCLOSURES The basic price pages contain pricing for totally enclosed and drip-proof guarded force-ventilated motors. The IEC enclosure terminology is shown for reference only. Drip proof Guarded Force Ventilated (IEC IP23/IC06) - ratings through 1000 HP (725kw) at 1750 RPM continuous duty (S1) are available. Totally Enclosed Non-Ventilated (IEC IP44/IC410) - ratings available through 100 HP (75kw) continuous duty (S1), and 400 HP (300kw) 60 minute duty (S2-60 minutes) Totally Enclosed Fan Cooled (IEC IC411) - ratings available through 250 HP (186kw) at 1750 RPM Totally Enclosed Blower Cooled (IEC 416)- ratings available through 500 HP at 1750 RPM; IEC IC416 available up to 300kw at 1450 RPM. Motors designed for higher than standard speeds may use special bearing construction other than stated above. General Information For pricing information or to place orders, go to M-188

7 ENCLOSURES con t The selection of the proper enclosure is vital to the successful safe operation of AC motors. The wrong enclosure can pose hazards to operating personnel and endanger other equipment. In addition, machine performance and life can be materially reduced by using an enclosure inappropriate for the application. The customer must recognize the specific environmental conditions and specify the correct enclosure. Reliance Electric can provide application assistance but must depend on the customer to provide accurate information on the operating conditions. The information in this section and the Modification Section should be studied thoroughly before specifying an enclosure. As indicated in the Introduction Section, the basic RPM AC motor may be Drip-proof Guarded Force Ventilated, Drip-proof Guarded Separately Ventilated or totally enclosed. The minimum enclosure for RPM AC motors is Drip-proof Guarded (Force Ventilated) as defined by NEMA MG to prevent accidental exposure to live metal or rotating parts. The drip-proof construction permits successful operation when drops of liquid or solid particles strike or enter the enclosure at any angle from 0 to 15 degrees downward from the vertical. Certain applications may require the Splashproof Guarded (Force Ventilated) machine to permit successful operation when drops of liquid or solid particles strike or enter the enclosure at any angle not greater than 100 degrees downward from the vertical. Both Drip-proof Guarded Force Ventilated and Splashproof Guarded Force Ventilated machines have a blower driven by a constant speed AC motor mounted on the end bracket to provide cooling independent of AC motor speed. A filter may be added to the blower when filterable contaminants are present in amounts not sufficient to rapidly clog the filter. A filter is not recommended in extremely dusty, dirty locations. Drip-Proof Guarded Force Ventilated (DPFV) Motor cooling is provided by motor-mounted blower driven by an integrally mounted three-phase blower motor. CAUTION: The blower cooling system is designed for optimum cooling air flow. Blowers must not have any auxiliary duct work connected to the inlet shroud since reduction in air flow and motor overheating will occur. Drip-Proof Guarded Separately Ventilated (DPSV) For applications where cooling air is ducted to the motor from an external source provided by the customer. For dusty, dirty environments, a totally enclosed machine is required to prevent the free exchange of air between the inside and outside of the enclosure but not sufficiently enclosed to be termed air-tight. Totally Enclosed Air Over-Blower Cooled (TEBC) RPM AC in-line blower cooled motors incorporate unique integral air ducts in the stator frame, external to the windings, to provide maximum cooling effectiveness. The integrally mounted, independently powered threephase blowers result in low noise levels over wide speed ranges. TEAO- Piggyback blower is available as an option. Totally Enclosed Non-Ventilated (TENV) Does not require any external air flow for cooling. Totally Enclosed Fan Cooled (TEFC) Exterior surface cooled by external fan mounted on motor shaft, therefore making motor cooling dependent on motor speed. XT Features Provides protection against corrosive, moist and dirt laden environments as encountered in paper, chemical and similar industries. Applicable to totally enclosed motors built in frames RL210 - L440 only. Outdoor Duty/Washdown Duty Suitable for operation outdoors subject to direct weather conditions, or for frequent washdown by high pressure water or steam. Available in all frame sizes RL210 - L440 on production basis. Paper Mill Duty Features Designed for operation at the wet end of a paper mill and in other harsh industrial environments. Totally Enclosed Pipe-Ventilated (TEPV) or Totally Enclosed Separately-Ventilated (TESV) Motor is cooled by customer supplied air which is piped into the machine and ducted out of the machine by customer supplied ducts. FINISH-PAINT Standard finish is Reliance Electric blue-green (Munsell Color System 8.5BG3.57/2.0) high-grade modified epoxy, air dry enamel with nontoxic rust inhibitors. GROUNDING Motors powered from adjustable frequency controllers will have voltages induced on inactive components, such as the motor frame, as a result of capacitive coupling of the switched voltage wavefronts from the controllers. PROPER GROUNDING OF THE MOTOR FRAME IS ESSENTIAL. All RPM AC motors have a ground lead provided in the motor conduit box as standard for grounding. INSULATION SYSTEM The standard insulation system for RPM AC is thermally rated for NEMA Class H of 180 C. All components of the system have been carefully selected to be fully compatible with any IGBT voltage source type controller, whether it is PWM or VVI. Premium VPI insulation is standard on all RPM AC L440 frames. MOUNTING All RPM AC frames are suitable for floor, wall or ceiling mount and with shaft at any angle from horizontal to vertical. M-189

8 Large AC OVERLOADS Momentary Overloads - all RPM AC motors have been designed for an overload capability of 150% (for DPFV) and 200% (for TEBC, TENV, and TEFC) of the base speed full load torque for 1 minute at all speeds within the constant torque speed range Inverter Duty AC Motors TEFC With Hollow Shaft HS35 Encoder Typical RPM Motor Construction With Totally Enclosed In-line Blower and Pulse Tachometer RPM AC Inverter Duty RPM XL Small DC Motors RPM III Medium DC Motors TACHOMETER MOUNTING All RPM AC motors have as a standard feature a machined opposite drive end bracket and tapped shaft provision for stub shaft for mounting an integral encoder. Mounting kits are available for selected encoders. The most cost effective encoder selection is a hollow shaft design and since it mounts on the stub shaft, no coupling or adapter is required. A tether arm mounts to the motor bracket. For TEFC motors in RL210 - L400 frames, a fan cover with machined fit for accessory mounting is available as a modification, if brakes and/or coupled/bearingless encoders are required. See Variable Speed catalog RAPS for detail. TEST - STANDARD DPFV 1000HP 1750 RPM L4461 Frame Each motor is given a full load test on a PWM power supply, and a routine test in accordance with IEEE 112 as modified by Reliance Electric for inverter power. This provides customers with assurance that all motors meet design specifications. Routine test consists of: Stator winding resistance Hi potential test No load and full load amps No load and full load speed See Modification section for price to supply certified routine test report price and other test options. THERMAL PROTECTION All RPM AC motors include three normally closed thermostats (1 per phase) connected in series, as standard. Leads are brought into the main conduit box as standard. General Information For pricing information or to place orders, go to M-190

9 SMALL RPM AC MOTOR Totally enclosed, non-ventilated and blower cooled enclosures meet IP44. (1/3 to 5 HP) Washdown Duty, totally enclosed, non-ventilated enclosures meet IP55. (1/3 to 3 HP) Mounting configured for C-Face foot mounted as standard. Top mounted conduit box capable of F1 or F2 lead location. 1000:1 Constant Torque Speed Range. Constant Horsepower to 150% of base speed. NEMA Design B, Class F insulation, 1.0 Service Factor, 40 Degree C Ambient Blower on TEBC is 1 phase 50/60 Hz Volt input. Modifications available. Frame sizes T, W180T RPM AC: TEFC,TEBC and TENV Compact Vector Duty designs TEFC with 1000:1 constant torque range Totally enclosed, blower cooled (TEBC) complete with 3 phase 230/460 volt blower motor Totally enclosed non-ventilated (TENV) requires no fan or blower for cooling - Prevents entry of dust, grit or moisture - Available with XT (Extra Tough) features for severe environments in frames RL210 - L440 - Available in-line or piggy-back blower Wide speed range : 1 constant torque, 2:1 constant horsepower - 100% zero speed continuously High overload torque - 200% overload torque for 1 minute, base speed and below Designed to accept encoders, brakes and a full line of optional accessories - see modification and accessory pages Encoder provisions include machined opposite drive end flange and tapped hole for stub shaft First to meet and exceed NEMA MG-1 Part 31 specification for spike voltage withstand Encoder provisions include machined opposite drive end flange and tapped hole for stub shaft Three normally closed thermostats - one per phase Cast iron end brackets on RL210-L440 frames TEFC 1000:1 Constant Torque RL2162 Frame TENV TEBC M-191

10 Large AC RPM AC MOTORS Description Designed for optimum variable speed performance on AC controllers. The square laminated frame design achieves maximum adjustable speed performance. Ideal for use in demanding applications such as paper machines, machine tools, printing presses, extruders, cut-to-length, crane and hoist. All are suitable for full torque at zero speed continuously. Inverter Duty AC Motors RPM AC Inverter Duty TEFC Enclosure 1000:1 Constant Torque HP TEFC Enclosure 200% overload - 1 minute base speed and below Top mounted conduit box standard (F-1, F-2 Option) Class H insulation Compact Low inertia Fast Response Optimized 4 pole design RL210 - L400 frames PLS lubrication in L280 - L400 frames Cast iron brackets Meets IP44 Drip-Proof Guarded Force Ventilated (DPGFV) 1000:1 Constant Torque HP 150% overload - 1 minute base speed and below F1 conduit box standard in RL210-L440 Class H insulation Most compact Lowest inertia Fast response Optimized 4 pole design (6 pole L440) RL210-L440 Frame PLS Lubrication in L280-L440 frames Cast iron brackets Meets IP23 Totally Enclosed Blower Cooled and Totally Enclosed Non-Ventilated 1000:1 Constant Torque HP 200% overload - 1 minute base speed and below 2:1 constant HP (1) Top mounted conduit box standard RL210- L400 frames. F-1 on L440 frame Class H insulation Compact Low inertia Fast response Optimized 4 pole design (6 pole L440) RL210 - L440 Frame PLS Lubrication in L280-L440 frame Cast iron brackets Meets IP44 RPM III Medium DC Motors RPM XL Small DC Motors (1) See pricing and application sections for speed limitations General Information For pricing information or to place orders, go to M-192

11 RPM AC MOTORS Features 1000:1 constant torque Full continuous torque at zero speed Standard encoder provisions include machined bracket and tapped hole for stub shaft 40ì C Ambient Service Factor Stock encoder kits available for all ratings. See RPM AC Accessories Ball Bearing C-Face With Feet or Foot Mounted as shown - Without Encoder 1/3-1000HP HP 1/3 1/2 3/ Notes: Speed, RPM Base CHP (1) Voltage Frame Enclosure Model Three normally closed thermostats (one per phase) Surpasses the requirements of NEMA MG-1 Part 31 for spike voltage withstand List Price Norm. Stock Notes Dimensions Sheet Design /460 FB56C TENV P56H6602 $343 N M / /460 FB56C TENV-EZ P56H N M / /460 FB56C TENV P56H Yes M4626F 1/ /460 FB56C TENV-EZ P56H N M4626 1/ /460 FB56C TENV P56H N M6717C 1.4/ /460 FB56C TENV-EZ P56H N M6717C 1.4/ /460 FB56C TENV P56H N M / /460 FB56C TENV-EZ P56H N M / /460 FB56C TENV P56H Yes M2941V 1.6/ /460 FB56C TENV-EZ P56H N M2941V 1.6/ /460 FB56C TENV P56H N M6718F 2./ /460 FB56C TENV-EZ P56H N M6718F 2./ /460 FB56C TENV P56H N M / /460 FB56C TENV-EZ P56H N M / /460 FB56C TENV P56H Yes M2966T 2.2/ /460 FB56C TENV-EZ P56H N M2966T 2.2/ /460 FC56C TENV P56H N M0149V 3/ /460 FC56C TENV-EZ P56H N M0149V 3/ /460 WC143TC TENV P14A N M / /460 WC143TC TENV-EZ P14A N M / /460 WC143TC TENV P14A Yes M2968Z 3.2/ /460 WC143TC TENV-EZ P14A Yes M2968Z 3.2/ /460 WC143TC TENV P14A N M8035V 3.6/ /460 WD143TC TENV-EZ P14A N M8035V 3.6/ /460 WC143TC TENV P14A N M / /460 WD143TC TENV-EZ P14A N M / /460 WC143TC TENV P14A Yes M / /460 WC143TC TENV-EZ P14A Yes M / /460 WE145TC TENV P14A N M8081V 4.4/ /460 WE145TC TENV-EZ P14A N M8081V 4.4/2.2 For the current version of Inverter Duty Motors dimension sheets, connection diagrams, design curves, etc., go to See delivery cycle sheet where N is shown above 4 week delivery based on non-modified model number shown, from date received at the plant.modifications may increase lead time. For motors with mounted encoder, (1/3-200 HP) See Page M-258 (*): Includes VPI, Stator RTDs, Grounding Brush, Insulated Bearing (O.D.E.), 3 thermostats. (2) Requires a minimum inverter carrier frequency of 4 Khz (1) CHP = Constant HP speed All L440 frames include VPI insulation and an insulated opposite drive end bearing. Price Symbol - RPMST FLA (59) M-193

12 RPM III Medium DC Motors RPM XL Small DC Motors RPM AC Inverter Duty Inverter Duty AC Motors Large AC RPM AC MOTORS 1000:1 Constant Torque 1/3-1000HP con t HP Notes: Speed, RPM Base CHP (1) Voltage Frame Enclosure Model List Price Norm. Stock Notes Dimensions Sheet Design /460 WD145TC TENV P14A6902 $690 N M8082 5/ /460 WE145TC TENV-EZ P14A N M8082 5/ /460 WD145TC TENV P14A Yes M8058B 6./ /460 WD145TC TENV-EZ P14A Yes M8058B 6./ RL2153 TENV P21R335 2,332 4 weeks RL2153 TENV P21R336 2,390 4 weeks RL2153 TENV P21R337 2,465 4 weeks /460 WE182TC TENV P18A weeks M / /460 WE182TC TENV-EZ P18A weeks M / /460 WE182TC TENV P18A Yes M8070A 8.8/ /460 WE182TC TENV-EZ P18A Yes M8070A 8.8/ RL2153 TENV P21R338 2,440 4 weeks RL2153 TENV P21R339 2,465 4 weeks RL2153 TENV P21R340 2,590 4 weeks /460 WE184TC TEBC P18A weeks M / RL2153 TENV P21R341 2,355 4 weeks RL2153 TENV P21R386 3,370 4 weeks /460 WE184TC TEBC P18A Yes M4466AC 14.2/ /460 RL2153C TENV P21R Yes 93 (180TC) L0060A 13.6/ RL2158 TENV P21R342 2,595 4 weeks RL2162 TENV P21R343 2,870 4 weeks RL2153 TEBC P21R344 2,682 4 weeks RL2153 TEBC P21R345 2,933 4 weeks RL2173 TENV P21R256 2,980 4 weeks RL2153 TENV P21R346 2,490 4 weeks RL2153 TENV P21R387 3,538 4 weeks FLA (59) /460 RL2158C TENV P21R308 2,675 Yes 94 (210TC) L0056A 21.4/ /460 RL2162 TENV P21R347 2,854 4 weeks / RL2153 TEBC P21R348 2,980 4 weeks RL2158 TEFC P21R382 2,895 4 weeks RL2153 TEBC P21R333 3,040 4 weeks RL2173 TENV P21R257 3,205 4 weeks RL2158 TEBC P21R349 3,439 4 weeks RL2578 TENV P25R240 4,140 4 weeks For the current version of Inverter Duty Motors dimension sheets, connection diagrams, design curves, etc., go to See delivery cycle sheet where N is shown above 4 week delivery based on non-modified model number shown, from date received at the plant.modifications may increase lead time. For motors with mounted encoder, (1/3-200 HP) See Page M-258 (*): Includes VPI, Stator RTDs, Grounding Brush, Insulated Bearing (O.D.E.), 3 thermostats. (2) Requires a minimum inverter carrier frequency of 4 Khz (1) CHP = Constant HP speed All L440 frames include VPI insulation and an insulated opposite drive end bearing. Price Symbol - RPMST General Information For pricing information or to place orders, go to M-194

13 RPM AC MOTORS 1000:1 Constant Torque 1/3-1000HP con t HP Notes: Speed, RPM Base CHP (1) Voltage Frame Enclosure Model List Price Norm. Stock Notes Dimensions Sheet Design /460 RL2158 TENV P21R320 $2,680 4 weeks / RL2158 TENV P21R350 3,775 4 weeks /460 RL2162C TENV P21R309 2,788 Yes 94 (210TC) L0040A 28/ RL2162 TEFC P21R329 3,095 4 weeks RL2158 TEBC P21R351 3,175 4 weeks RL2173 TENV P21R258 3,120 4 weeks RL2153 DPG-FV P21R371 2,820 4 weeks RL2162 TEFC P21R302 2,940 4 weeks RL2158 TEBC P21R383 3,425 4 weeks RL2578 TENV P25R271 3,730 4 weeks RL2158 DPG-FV P21R352 3,490 4 weeks RL2168 TEBC P21R259 3,810 4 weeks RL2586 TENV P25R241 4,540 4 weeks RL2162 DPG-FV P21R260 3,810 4 weeks RL2153 DPG-FV P21R353 2,860 4 weeks RL2153 TEBC P21R354 3,010 4 weeks /460 RL2158 TENV P21R330 3,054 4 weeks / RL2153 DPG-FV P21R355 2,935 4 weeks RL2153 TEBC P21R356 4,188 4 weeks RL2162 TENV P21R295 4,242 4 weeks RL2153 DPG-FV P21R357 2,680 4 weeks RL2158C TEFC P21R358 2,870 Yes 95 (250TC) L1517A RL2153 TEBC P21R359 2,880 4 weeks RL2173 TENV P21R303 2,980 4 weeks L2401A RL2153 DPG-FV P21R372 2,810 4 weeks RL2168 TEFC P21R296 3,145 4 weeks L2386A RL2162 TEBC P21R360 3,267 4 weeks RL2586 TENV P25R243 3,692 4 weeks RL2158 DPG-FV P21R361 3,125 4 weeks RL2578 TEFC P25R284 3,290 4 weeks RL2162 TEBC P21R297 3,760 4 weeks L2882 TENV P28L240 7,980 N RL2162 DPG-FV P21R263 4,240 4 weeks RL2173 TEBC P21R264 4,955 4 weeks L2898 TENV P28L241 8,951 N RL2173 DPG-FV P21R265 4,820 4 weeks For the current version of Inverter Duty Motors dimension sheets, connection diagrams, design curves, etc., go to See delivery cycle sheet where N is shown above 4 week delivery based on non-modified model number shown, from date received at the plant.modifications may increase lead time. For motors with mounted encoder, (1/3-200 HP) See Page M-258 (*): Includes VPI, Stator RTDs, Grounding Brush, Insulated Bearing (O.D.E.), 3 thermostats. (2) Requires a minimum inverter carrier frequency of 4 Khz (1) CHP = Constant HP speed All L440 frames include VPI insulation and an insulated opposite drive end bearing. Price Symbol - RPMST FLA (59) M-195

14 General Information RPM III Medium DC Motors RPM XL Small DC Motors RPM AC Inverter Duty Inverter Duty AC Motors Large AC RPM AC MOTORS 1000:1 Constant Torque 1/3-1000HP con t HP Notes: Speed, RPM Base CHP (1) Voltage Frame Enclosure Model List Price Norm. Stock For pricing information or to place orders, go to Notes Dimensions Sheet Design RL2153 DPG-FV P21R363 $3,048 4 weeks RL2153 TEBC P21R323 3,286 4 weeks RL2570 TENV P25R244 3,410 4 weeks RL2153 DPG-FV P21R362 3,110 4 weeks RL2158 TEFC P21R384 2,980 4 weeks RL2153 TEBC P21R364 4,530 4 weeks RL2173 TENV P21R298 4,860 4 weeks RL2153C DPG-FV P21R365 2,948 4 weeks 95 (250TC) RL2162C TEFC P21R283 2,990 Yes 95 (250TC) L0514A RL2158C TEBC P21R314 3,005 Yes 95 (250TC) L0021A RL2578 TENV P25R245 3,340 4 weeks L1876A RL2162 DPG-FV P21R315 3,144 4 weeks 95 (250TC) RL2578 TEFC P25R285 3,380 4 weeks RL2168 TEBC P21R272 3,490 4 weeks L1756A L2890 TENV P28L242 8,087 N RL2162 DPG-FV P21R235 3,484 4 weeks RL2586 TEFC P25R286 4,190 4 weeks RL2173 TEBC P21R273 4,010 4 weeks L2898 TENV P28L243 9,180 N RL2168 DPG-FV P21R274 4,655 4 weeks RL2578 TEBC P25R246 5,787 4 weeks L3203 TENV P32L263 11,688 N RL2570 DPG-FV P25R247 5,684 4 weeks RL2153 DPG-FV P21R366 3,252 4 weeks RL2153 TEBC P21R331 3,481 4 weeks RL2578 TENV P25R248 5,490 4 weeks RL2153 DPG-FV P21R367 3,312 4 weeks RL2162 TEFC P21R299 3,230 4 weeks RL2162 TEBC P21R385 4,755 4 weeks RL2578 TENV P25R249 7,340 4 weeks RL2158C DPG-FV P21R368 3,166 4 weeks 95 (250TC) RL2173C TEFC P21R286 3,288 Yes 95 (250TC) L1819A RL2162C TEBC P21R287 3,240 Yes 95 (250TC) L0022A RL2586 TENV P25R287 3,984 4 weeks L2402A RL2162 DPG-FV P21R237 3,581 4 weeks L0349A RL2586 TEFC P25R288 4,120 4 weeks RL2173 TEBC P21R275 3,925 4 weeks L1766A L2898 TENV P28L245 9,144 N RL2168 DPG-FV P21R276 4,010 4 weeks L3203 TENV P32L264 11,155 N RL2578 TEBC P25R250 4,910 4 weeks RL2570 DPG-FV P25R251 5,370 4 weeks L2882 TEBC P28L246 9,105 N L3213 TENV P32L265 12,995 N RL2586 DPG-FV P25R252 7,320 4 weeks For the current version of Inverter Duty Motors dimension sheets, connection diagrams, design curves, etc., go to See delivery cycle sheet where N is shown above 4 week delivery based on non-modified model number shown, from date received at the plant.modifications may increase lead time. For motors with mounted encoder, (1/3-200 HP) See Page M-258 (*): Includes VPI, Stator RTDs, Grounding Brush, Insulated Bearing (O.D.E.), 3 thermostats. (2) Requires a minimum inverter carrier frequency of 4 Khz (1) CHP = Constant HP speed All L440 frames include VPI insulation and an insulated opposite drive end bearing. Price Symbol - RPMST FLA (59) M-196

15 RPM AC MOTORS 1000:1 Constant Torque 1/3-1000HP con t HP Notes: Speed, RPM Base CHP (1) Voltage Frame Enclosure Model List Price Norm. Stock Notes Dimensions Sheet Design RL2153 DPG-FV P21R317 $3,376 4 weeks RL2158 TEBC P21R328 3,745 4 weeks RL2586 TENV P25R289 5,940 4 weeks RL2153 DPG-FV P21R369 3,455 4 weeks RL2173 TEFC P21R300 3,440 4 weeks RL2586 TENV P25R290 6,165 4 weeks RL2162 TEBC P21R277 4,676 4 weeks L0181A RL2158C DPG-FV P21R327 3,310 Yes 95 (250TC) L1206A RL2578C TEFC P25R278 3,460 Yes 95 (250TC) L2380A RL2162C TEBC P21R294 3,430 Yes 95 (250TC) L2381A L2898 TENV P28L248 8,951 N RL2168 DPG-FV P21R250 4,290 Yes L1767A RL2578 TEBC P25R253 4,685 4 weeks L1870A L3203 TENV P32L236 11,240 N RL2173 DPG-FV P21R278 4,435 4 weeks RL2586 TEBC P25R291 5,511 4 weeks L2052A L3213 TENV P32L237 12,975 N RL2578 DPG-FV P25R255 6,620 4 weeks L2890 TEBC P28L249 9,544 N L4022 TENV P40L217 17,835 N RL2586 DPG-FV P25R256 7,660 4 weeks RL2158 DPG-FV P21R324 3,455 4 weeks RL2168 TEBC P21R279 4,130 4 weeks L2898 TENV P28L250 9,780 N RL2158 DPG-FV P21R370 3,573 4 weeks RL2578 TEFC P25R292 4,187 4 weeks RL2173 TEBC P21R280 6,775 4 weeks L3203 TENV P32L269 12,760 N RL2162 DPG-FV P21R211 3,550 Yes L0231A RL2586 TEFC P25R279 3,765 Yes L1881A RL2173 TEBC P21R285 3,580 Yes L2327A L3203 TENV P32L238 11,240 N RL2168 DPG-FV P21R251 4,843 4 weeks L1814A RL2586 TEBC P25R257 5,176 4 weeks L1871A L3213 TENV P32L239 12,975 N RL2578 DPG-FV P25R258 6,780 4 weeks L2890 TEBC P28L252 8,842 N L4022 TENV P40L218 17,100 N RL2586 DPG-FV P25R259 7,341 4 weeks L2898 TEBC P28L253 10,200 N L4022 TENV P40L219 17,235 N L2882 DPG-FV P28L254 9,780 N For the current version of Inverter Duty Motors dimension sheets, connection diagrams, design curves, etc., go to See delivery cycle sheet where N is shown above 4 week delivery based on non-modified model number shown, from date received at the plant.modifications may increase lead time. For motors with mounted encoder, (1/3-200 HP) See Page M-258 (*): Includes VPI, Stator RTDs, Grounding Brush, Insulated Bearing (O.D.E.), 3 thermostats. (2) Requires a minimum inverter carrier frequency of 4 Khz (1) CHP = Constant HP speed All L440 frames include VPI insulation and an insulated opposite drive end bearing. Price Symbol - RPMST FLA (59) M-197

16 RPM III Medium DC Motors RPM XL Small DC Motors RPM AC Inverter Duty Inverter Duty AC Motors Large AC RPM AC MOTORS 1000:1 Constant Torque 1/3-1000HP con t HP Notes: Speed, RPM Base CHP (1) Voltage Frame Enclosure Model List Price Norm. Stock Notes Dimensions Sheet Design RL2162 DPG-FV P21R325 $4,420 4 weeks RL2173 TEBC P21R266 5,308 4 weeks L2898 TENV P28L255 12,087 N RL2168 DPG-FV P21R267 4,515 4 weeks RL2586 TEFC P25R293 4,465 4 weeks L2400A RL2173 TEBC P21R301 7,282 4 weeks L3203 TENV P32L240 12,980 N RL2168 DPG-FV P21R254 3,960 Yes L1757A RL2578 TEBC P25R234 4,620 Yes L1823A L3203 TENV P32L241 11,365 N RL2570 DPG-FV P25R217 5,730 Yes L0191A L2882 TEBC P28L256 8,680 N L4022 TENV P40L220 17,370 N RL2578 DPG-FV P25R261 7,160 4 weeks L2898 TEBC P28L257 9,641 N L4034 TENV P40L221 18,973 N L2882 DPG-FV P28L258 10,440 N L3213 TEBC P32L242 12,810 N L4034 TENV P40L222 22,302 N L2898 DPG-FV P28L259 11,300 N RL2168 DPG-FV P21R268 4,945 4 weeks RL2578 TEBC P25R262 6,240 4 weeks L3203 TENV P32L243 12,200 N RL2168 DPG-FV P21R269 4,610 4 weeks L3213 TENV P32L244 13,444 N RL2578 TEBC P25R263 8,421 4 weeks RL2168 DPG-FV P21R247 4,780 Yes L1765A RL2586 TEBC P25R232 5,980 Yes L1820A L3607 TENV P36L224 16,912 N RL2578 DPG-FV P25R237 6,970 Yes L1866A L2898 TEBC P28L260 9,240 N L4034 TENV P40L223 19,494 N RL2586 DPG-FV P25R264 8,155 4 weeks L3203 TEBC P32L245 10,320 N L4046 TENV P40L224 21,400 N L2890 DPG-FV P28L261 11,360 N L4022 TEBC P40L206 19,800 N L2898 DPG-FV P28L262 12,520 N For the current version of Inverter Duty Motors dimension sheets, connection diagrams, design curves, etc., go to See delivery cycle sheet where N is shown above 4 week delivery based on non-modified model number shown, from date received at the plant.modifications may increase lead time. For motors with mounted encoder, (1/3-200 HP) See Page M-258 (*): Includes VPI, Stator RTDs, Grounding Brush, Insulated Bearing (O.D.E.), 3 thermostats. (2) Requires a minimum inverter carrier frequency of 4 Khz (1) CHP = Constant HP speed All L440 frames include VPI insulation and an insulated opposite drive end bearing. Price Symbol - RPMST FLA (59) General Information For pricing information or to place orders, go to M-198

RPM AC INTEGRAL HP INVERTER DUTY MOTORS

RPM AC INTEGRAL HP INVERTER DUTY MOTORS RPM AC INTEGRAL INVERTER DUTY MOTORS Table of Contents Page General Information......................... 242 General Features........................... 242 Standard Motor Features Agency Listing..........................

More information

Inverter Duty AC Motors

Inverter Duty AC Motors inverter_duty_ac_motors.fm Page 225 Tuesday, December 17, 2002 3:12 PM RPM AC RPM III Medium DC Motors Index 225 Index RPM III Medium DC Motors RPM AC Inverter Duty Vector Inverter Duty Totally Enclosed

More information

RPM AC MOTORS MODIFICATION INDEX

RPM AC MOTORS MODIFICATION INDEX RPM AC INVERTER DUTY MOTORS MODIFICATIONS INDEX RPM AC MOTORS MODIFICATION INDEX Page ADAPTER BASES OR RAILS Adapter Base................................................. B-64 Adapter Rails.................................................

More information

VARIABLE SPEED AC MOTORS 1/3-2,500 HP INVERTER DUTY MOTORS

VARIABLE SPEED AC MOTORS 1/3-2,500 HP INVERTER DUTY MOTORS VARIABLE SPEED AC MOTORS 1/3-2,500 HP INVERTER DUTY MOTORS IN 1904, RELIANCE ELECTRIC INTRODUCED THE WORLD'S FIRST VARIABLE SPEED MOTOR. FOR OVER 96 YEARS, RELIANCE ELECTRIC MOTORS HAVE LED THE INDUSTRY

More information

Inverter Duty and Inverter Duty - Vector Performance AC Motor Product Line

Inverter Duty and Inverter Duty - Vector Performance AC Motor Product Line Large AC Inverter Duty and Inverter Duty - Vector Performance AC Motor Product Line Inverter Duty 1/3-2 HP, 56-140 frame sizes, Explosion Proof, Class I, Groups C & D, Class 2, Groups F & G, XT - Extra

More information

Variable Speed Motor Products

Variable Speed Motor Products Variable Motor Products Why Baldor? Customer Preference 90% 2000 20% 1985 50% 1990 Percentage of research studies in which Baldor was chosen most preferred. For nearly 100 years, Baldor has strived to

More information

Inverter Speed Ratio Information

Inverter Speed Ratio Information Inverter Speed Ratio Information Guidelines for Application of General Purpose,, Single Speed on Variable Frequency Drives Meets NEMA MG1-2006 Part 30 and Part 31 Section 4.4.2 Unless stated otherwise,

More information

RPM AC MOTOR APPLICATION INDEX

RPM AC MOTOR APPLICATION INDEX INDEX RPM AC MOTOR INDEX Page AIR SUPPLY DPSV - CFM & Static Pressure Measurements....................... B-82 BALANCE Standard Machine Vibration Limits................................. B-83 Standard Dynamic

More information

Small and Medium DC Motors

Small and Medium DC Motors Large AC Small and Medium DC Motors RPM III Medium DC Motors General Information RPM AC Inverter Duty Inverter Duty AC Motors For pricing information or to place orders, go to www.ptplace.com M-222 RPM

More information

Blue Max 2000 Vector Duty 2000:1 Constant Torque Motors

Blue Max 2000 Vector Duty 2000:1 Constant Torque Motors Blue Max 2000 Vector Duty 2000:1 Constant Torque Motors Applications: Blue Max motors are used in variable frequency drive applications requiring full rated torque at zero speed, utilizing Closed- or Open-Loop

More information

INTEGRAL HP DC MOTORS INDEX

INTEGRAL HP DC MOTORS INDEX GENERAL INFORMATION INTEGRAL HP DC MOTORS INDEX STOCK RATINGS..............................................................M-250 GENERAL FEATURES..........................................................M-257

More information

Industrial and Commercial Duty IEC Motors

Industrial and Commercial Duty IEC Motors Industrial and Commercial Duty IEC Motors A Regal Brand Five product families delivering a world of opportunity LEESON Passport Series IEC Motors. There s a world of opportunity right here at home. The

More information

Small and Medium DC Motors

Small and Medium DC Motors Small and Medium DC Motors Inverter Duty AC Motors RPM AC Inverter Duty RPM III Medium DC Motors General Information Introduction M-283 Introduction General Information RPM III Medium DC Motors Inverter

More information

THREE PHASE MOTORS RIGID BASE GENERAL PURPOSE Rigid Base

THREE PHASE MOTORS RIGID BASE GENERAL PURPOSE Rigid Base THREE PHASE MOTORS DRIP-PROOF RPM 60 HP Hz 1/4 1725 1725 S56 100027 $246 A 16 208-230/460 1.4 58.0 9.24 1/3 3450 48 101447 251 A 14 208-230/460 1.4 68.0 9.00 1725 48 100446 266 A 17 208-230/460 1.6 64.3

More information

Inverter (Vector) Duty: micromax TM 1000:1 Constant Torque (TENV), 20:1 Constant Torque (TEFC) Totally Enclosed

Inverter (Vector) Duty: micromax TM 1000:1 Constant Torque (TENV), 20:1 Constant Torque (TEFC) Totally Enclosed Inverter (Vector) Duty: micromax TM 1000:1 Constant Torque (TENV), 20:1 Constant Torque (TEFC) Totally Enclosed Applications: Designed for direct replacement of PMDC or any other variable speed application

More information

AC Line / Load Reactors

AC Line / Load Reactors AC Line / Load Reactors Table of Contents Delivery / Lead Time.PB03-1100 -2 Selection & Pricing PB03-1100 -4 Replacement Parts..PB03-1100-8 Product Modifications / Options..PB03-1100 -9 Product Specifications..PB03-1100

More information

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency The Baldor uper-e In the mid-70s, a southeastern tire manufacturing plant asked Baldor to increase their plant s operating efficiencies. After analyzing the efficiencies of the plant s 75 Hp motors, Baldor

More information

SEWPCC UPGRADING/EXPANSION PROJECT BID OPPORTUNITY SECTION LOW-VOLTAGE AC INDUCTION MOTORS

SEWPCC UPGRADING/EXPANSION PROJECT BID OPPORTUNITY SECTION LOW-VOLTAGE AC INDUCTION MOTORS SECTION 26 20 00 LOW-VOLTAGE AC INDUCTION MOTORS SEWPCC UPGRADING/EXPANSION PROJECT PART 1 GENERAL 1.1 RELATED SECTIONS A. This section applies only when referenced by a motor-driven equipment specification.

More information

180VC WITH B5 FLANGE / M ,6 0, / M l 5,0 0,7 192 / M ,0 0,9 223

180VC WITH B5 FLANGE / M ,6 0, / M l 5,0 0,7 192 / M ,0 0,9 223 METRIC (IEC) FRAME THYRISTOR RATED DC METRIC (IEC) FRAME MOTORS IP54 These metric dimensioned motors are built to IEC 34-1 electrical and mechanical standards. The IEC 63 and smaller frames are stocked

More information

Large AC Motors. Synchronous Reluctance Kiln Duty Submersible Accessories & Kits. Large AC Motors. Modifications Large AC M-211

Large AC Motors. Synchronous Reluctance Kiln Duty Submersible Accessories & Kits. Large AC Motors. Modifications Large AC M-211 Synchronous Reluctance Kiln Duty Submersible Accessories & Kits Modifications Large AC M-211 large_ac_motors.fm Page 212 Monday, December 15, 2003 3:47 PM, Quickship and Modifiable 250 HP - 1500 HP 3600

More information

SECTION MOTOR REQUIREMENTS for HVAC

SECTION MOTOR REQUIREMENTS for HVAC PART 1 GENERAL 1.1 SECTION INCLUDES A. Single-phase electric motors B. Three-phase electric motors 1.2 REFERENCES SECTION 23 05 13 MOTOR REQUIREMENTS for HVAC A. ABMA 9 - Load Ratings and Fatigue Life

More information

General Purpose Three Phase Motors TEFC (IP55) High Efficiency. Standard Features

General Purpose Three Phase Motors TEFC (IP55) High Efficiency. Standard Features TM WEG W21 Severe Duty motors meet the most demanding severe duty application requirements. These TEFC motors are all cast iron construction, with enclosures rated IP55 to handle wet and dirty environments.

More information

Stock Product Quick Reference Guide

Stock Product Quick Reference Guide Stock Product Quick Reference Guide A Regal Brand Thousands of solutions. One matched perfectly to your needs. More than 6,000 stock motors, gearmotors, gear reducers and control designs available. Yes,

More information

DC MOTORS NEMA FRAME SCR RATED

DC MOTORS NEMA FRAME SCR RATED NEMA FRAME SCR RATED NEMA FRAME MOTORS SCR RATED High voltage permanent magnet DC motors are typically used with an SCR (thyristor) controller in applications requiring adjustable speed and constant torque

More information

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency The Baldor uper-e In the mid-70s, a southeastern tire manufacturing plant asked Baldor to increase their plant s operating efficiencies. After analyzing the efficiencies of the plant s 75 Hp motors, Baldor

More information

Design Standard. Electric Motors. Detailed specifications follow. PART 1 - GENERAL

Design Standard. Electric Motors. Detailed specifications follow. PART 1 - GENERAL Design Standard Detailed specifications follow. PART 1 - GENERAL 1.01 SCOPE This design guidelines contained herein include the requirements of electric motors utilized for electric motor driven systems

More information

steel standard SST DUCK components Epoxy Resin Rated Insulation System recognized stainless steel output shaft seal

steel standard SST DUCK components Epoxy Resin Rated Insulation System recognized stainless steel output shaft seal Premium Efficiency Washguard Motors - Now Available! WASHGUARD MOTORS WASHGUARD MOTORS AVAILABLE IN FIVE STYLES Maximum service in critically clean or corrosive environments PREMIUM WASHGUARD ALL-STAINLESS

More information

Family Frame Size Constant Torque Variable Torque Comments Super-E Motors 230, 460 and 575 Volts (1) (1) 20:1 10:1

Family Frame Size Constant Torque Variable Torque Comments Super-E Motors 230, 460 and 575 Volts (1) (1) 20:1 10:1 ac Motor adjustable speed range capabilities & Controls inverter drive and vector drive Inverter Drive and Vector Drive exceed all requirements of NEMA MG-1 Parts 30 and 31 for AC induction motors powered

More information

WATTSAVER PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE

WATTSAVER PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE The line of premium efficiency motors is now inverter capable. LEESON s unique IRIS voltage-spike-resistant insulation system is standard at no extra cost. motors

More information

The Best Value in Washdown Duty Motors and Drives

The Best Value in Washdown Duty Motors and Drives The Best Value in Washdown Duty Motors and Drives Long before we invested in the people, equipment and material required to produce Baldor Reliance Washdown Duty motors and drives, we invested our time

More information

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency The Baldor uper-e In the mid-70s, a southeastern tire manufacturing plant asked Baldor to increase their plant s operating efficiencies. After analyzing the efficiencies of the plant s 75 Hp motors, Baldor

More information

Severe duty cast iron frame motors

Severe duty cast iron frame motors Severe duty cast iron frame motors When the going gets tough, these motors keep going SIMOTICS NEMA Low Voltage Motors www.usa.siemens.com/motors Siemens SIMOTICS low voltage severe duty motors Built to

More information

RPM III Medium DC Motors

RPM III Medium DC Motors 5-500 HP C210ATZ-C440ATZ Frames, GK112-GS280 Frames (IEC) RPM III DC Motors combine the best features of the Reliance Electric RPM and SUPER RPM DC Motors with new advances in design and construction.

More information

Three Phase Modifiable NEMA Horizontal Motors Accessories and Modifications

Three Phase Modifiable NEMA Horizontal Motors Accessories and Modifications 1. Altitude Standard motors are designed for 3,300 feet altitude and 40 C ambient temperature. Atmospheric conditions at higher altitudes inhibit the motor s ability to dissipate heat, resulting in an

More information

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1)

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1) 630-543-7867 Products & Services EQ7 1-1000 hp Intelligent Keypad with Extensive Diagnostics Select Any of 4 Control Methods - V/ Hz - Dynamic Torque - Sensorless Vector - Closed-loop Vector Quick Setup

More information

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT SECTION 230513 - COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Single phase electric motors. B. Three phase electric motors. 1.2 REFERENCE STANDARDS A. ABMA STD 9

More information

841XL PREMIUM EFFICIENCY MOTORS

841XL PREMIUM EFFICIENCY MOTORS 841XL PREMIUM EFFICIENCY MOTORS 8 4 1 X L A C M O T O R S D E S I G N E D T O M E E T Y O U R S E V E RE D U T Y N E E D S As an original member of the NEMA Energy Task Force, Rockwell Automation has

More information

SHADED RATINGS ARE CAST IRON FRAMES

SHADED RATINGS ARE CAST IRON FRAMES Gearmotors and NEMA AC C-Face Kits for Field Conversion Features: Complete kits with all hardware necessary for converting 56 through 445T frame rigid base motors to C-Face mounting with base. For a conversion,

More information

5 Year Warranty Premium Efficiency, TEFC Enclosure Inverter Duty Motors Corona Resistant Magnet Wire CSA Certified, UL, CE NEMA MG1 (2003) Part 31,

5 Year Warranty Premium Efficiency, TEFC Enclosure Inverter Duty Motors Corona Resistant Magnet Wire CSA Certified, UL, CE NEMA MG1 (2003) Part 31, 5 Year Warranty Premium Efficiency, TEFC Enclosure Inverter Duty Motors Corona Resistant Magnet Wire CSA Certified, UL, CE NEMA M1 (003) Part 31, DefinitePurpose Inverter Fed Motors Inverter Shield TM

More information

NEMA & IEC Product Features and Benefits

NEMA & IEC Product Features and Benefits NEMA & IEC Product Features and Benefits BEAUTY BENEATH THE SURFACE. Looking at a Techtop electric motor, it would be understandable if you thought it was just another NEMA or IEC squirrel-cage induction

More information

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation M T E C o r p o r a t i o n MTE Series RL Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL. 050516 2002 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RL Line/Load Reactors are components

More information

Reliance Electric Super RPM Large Variable Speed DC Motors: HP B500-B1600 Frame RPM

Reliance Electric Super RPM Large Variable Speed DC Motors: HP B500-B1600 Frame RPM Reliance Electric Super RPM Large Variable Speed DC Motors: 75-4000 HP B500-B1600 Frame 400-2400 RPM Engineered To Meet The Toughest Industrial Requirements Reliance Electric DC motor technology is the

More information

MTE AC Line / Load Reactors Price book

MTE AC Line / Load Reactors Price book Table of Contents TABLE OF CONTENTS...1 STANDARD DELIVERY SCHEDULE...2 REACTOR SELECTION & PRICING...4 208-240 VOLT (3-PHASE)...4 400 VOLT (50 HZ) USE FOR 380-415 VOLTS...5 480 VOLT (3-PHASE) REACTOR...6

More information

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents. PART 1: GENERAL 1.01 This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is to apply the

More information

A. Fan motors and associated equipment shall be sized to operate at 110% of calculated loads and capacities.

A. Fan motors and associated equipment shall be sized to operate at 110% of calculated loads and capacities. PART 1: GENERAL 1.01 This design guidelines contained herein includes the requirements electric motors utilized for electric motor driven systems at Texas State University. It is the intention of this

More information

DC Motors & Controls for many different applications

DC Motors & Controls for many different applications DC Motors & Controls for many different applications Baldor offers the widest variety of DC Motors. From 1/50 to 3000 horsepower, our rugged industrial designs may be used to power everything from a medical

More information

A Full Line of Low Voltage IEC Motors In-Stock

A Full Line of Low Voltage IEC Motors In-Stock BUILT TO PERFORM WHERE OTHERS FAIL A Full Line of Low Voltage IEC Motors In-Stock Distributed by Elektrim Motors Authorized Distributor: www.elektrimmotors.com or call 855-Go-Elektrim 0.08-220HP Low Voltage

More information

Motors Automation Energy Coatings. CrusherDuty. g Roller Bearing. g Reinforced Cast Iron. g Durable. Motor TPH Starter.

Motors Automation Energy Coatings. CrusherDuty. g Roller Bearing. g Reinforced Cast Iron. g Durable. Motor TPH Starter. Motors Automation Energy Coatings CrusherDuty Motor TPH Starter g Roller Bearing g Reinforced Cast Iron g Durable g Quality CD0808 FOR THE MOST DEMANDING ROCK CRUSHER APPLICATIONS WEG Crusher Duty motors

More information

FACTORY MODIFICATION PRICING Effective Supercedes

FACTORY MODIFICATION PRICING Effective Supercedes FACTORY MODIFICATION PRICING MODIFICATION LEAD TIME 1. TWMC standard lead time for all modifications is 5-10 working days. If quicker lead time is required, please contact TWMC. Expediting fees may apply.

More information

Quick and Easy Voltage Flexibility for NEMA and Metric IEC Motors Motors are re-rated from stock models to 575V in as little as (1) business day

Quick and Easy Voltage Flexibility for NEMA and Metric IEC Motors Motors are re-rated from stock models to 575V in as little as (1) business day Elektrim 7V s Quick and Easy Voltage Flexibility for NEMA and Metric IEC s s are re-rated from stock models to 7V in as little as () business day Available 7V s: -0 HP NEMA Premium Performance Series s

More information

INDEX INTEGRAL HP DC MOTORS APPLICATION DATA D-87

INDEX INTEGRAL HP DC MOTORS APPLICATION DATA D-87 INTEGRAL HP DC MOTORS INDEX Page SAFETY Enclosures...................................................... D90 Enclosure Enhancements.......................................... D91 DustProof Taconite Features.....................................

More information

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY TYPE AEHE, AEHH8N, AEHH8NCF, AEUH8NDC Effective 05-01-13 Supercedes 08-01-11 APPLICATIONS: Fans & Blowers Compressor Any Severe Duty/ Petro-Chem/ Pumps Mixers Pulp

More information

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S Revised 04/14/2016 SPECIFICATIONS - DETAILED PROVISIONS Section 16151 - Vertical Hollowshaft Electric Motors C O N T E N T S PART 1 - GENERAL... 1 1.01 SCOPE... 1 1.02 SPECIFIC PROJECT REQUIREMENTS...

More information

ABMA , Radial Bearings of Ball, Cylindrical Roller and Spherical Roller Types Metric Design.

ABMA , Radial Bearings of Ball, Cylindrical Roller and Spherical Roller Types Metric Design. Specification CT841-2016 Standard for Petroleum and Chemical Industry Definite Purpose, Severe- Duty, Totally Enclosed Air Over (TEAO) Permanent Magnet Synchronous Cooling Tower and Air Cooled Heat Exchanger

More information

Definite Purpose Motors. Three Phase, Two Speed, TEFC, Foot Mounted. 3/4 thru 25 Hp NEMA 56 thru 324T

Definite Purpose Motors. Three Phase, Two Speed, TEFC, Foot Mounted. 3/4 thru 25 Hp NEMA 56 thru 324T Unit Handling Brake 200 & 575 Volt IEC & Controls DC 158 Two Speed, TEFC, Cast Iron 3/4 thru 25 56 thru 324T Applications: Fans, blowers, machine tools, hoists, conveyors, pumps. Features: Designed for

More information

Data Bulletin. ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION DESIGN CONCEPT. Bulletin No. 8806DB0102 August 2001 Raleigh, NC, USA

Data Bulletin. ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION DESIGN CONCEPT. Bulletin No. 8806DB0102 August 2001 Raleigh, NC, USA Data Bulletin Raleigh, NC, USA ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION The ALTIVAR FLEX58 chassis drive controller offers OEMs, panel builders, integrators, and users a unique

More information

AC Induction Motors. Installation and operating instructions

AC Induction Motors. Installation and operating instructions AC Induction Motors Installation and File No: 48.80 Date: january 28, 2014 Supersedes: 48.80 Date: july 30, 2013 contents Receiving inspection and handling 4 Installation / mounting 4 Location 5 Electrical

More information

Why Baldor? Baldor Vector Drives in a brick plant in Australia

Why Baldor? Baldor Vector Drives in a brick plant in Australia Why Baldor? For over 80 years, Baldor has been dedicated to providing customers with the best value in energyefficient industrial electric motors and drives. To be considered as the best value supplier

More information

Over 525 Stock Motor Ratings. The Right Pump Motor for your Application. Leadership in Premium Efficiency. 1

Over 525 Stock Motor Ratings. The Right Pump Motor for your Application. Leadership in Premium Efficiency.   1 Baldor Pump Motors Baldor Reliance is the leading supplier of Pump Motors to meet industrial and commercial applications. From industrial waste water to commercial pool pump motors Baldor Reliance pump

More information

Features and Benefits

Features and Benefits Features and Benefits ELECTRICAL DESIN z 1 500 HP; 2, 4, 6 pole z 3600, 1800, 1200 RPM z 3 Phase, 60 Hz, 460V z Motors can be rerated for 380, 400 and 415 VAC at 50 Hz. z Designed to meet NEMA M1, M13,

More information

NEMA AC Motor C-Face Kits for Field Conversion

NEMA AC Motor C-Face Kits for Field Conversion Gear s NEMA AC C-Face Kits for Field Conversion Features: Complete kits with all hardware necessary for converting Baldor 56 through 445T frame rigid base motors to C-Face mounting with base. For a Baldor

More information

INDEX NEMA PREMIUM EFFICIENCY

INDEX NEMA PREMIUM EFFICIENCY INDEX S EED EXC DS R TS O DAR MEE E STAN CE THREE-PHASE MOTORS - FEATURES & LIST PRICES THREE-PHASE MOTORS TEFC - Foot-Mount................... A-51 A-54 TEFC C-Flange........................ A-55 ODP

More information

Comfort. Description. Applications

Comfort. Description. Applications Blower Heater 3-35 kw 10,236-119,420 Btuh 208, 240, 480 and 575 Volt 1 or 3 Phase Built-in Controls Description Type is designed to heat areas classified as hazardous locations to provide primary or supplementary

More information

20: (1) 20:1. General Purpose Premium Efficiency EM (ODP) :1 20:1 General Purpose Premium Efficiency :1 20:1 10:

20: (1) 20:1. General Purpose Premium Efficiency EM (ODP) :1 20:1 General Purpose Premium Efficiency :1 20:1 10: AC Motor Adjustable Speed Range Capabilities & Controls Inverter Drive and Vector Drive Inverter Drive and Vector Drive exceed all requirements of NEMA MG-1 Parts 30 and 31 for AC induction motors powered

More information

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation M T E C o r p o r a t i o n MTE Series RL Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL. 060227 2006 MTE Corporation Important User Information NOTICE MTE Series RL Line/Load Reactors are components

More information

VEM3546 1HP 1800RPM 3PH 56C Tefc Motor. Features. Description. Manufacturer Information

VEM3546 1HP 1800RPM 3PH 56C Tefc Motor. Features. Description. Manufacturer Information 3804 outh treet 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 VEM3546 1HP 1800RPM 3PH 56C Tefc Motor Baldor Electric CO. Catalog Number Manufacturer Description Weight per unit Product

More information

AutomationDirect AC Motors Selection Overview

AutomationDirect AC Motors Selection Overview AutomationDirect AC s Selection (1992), High, What does it all mean? In 1992, the U.S. Congress passed legislation requiring that general purpose Design A & B motors meet minimum efficiency requirements,

More information

Your Source for a Complete Line of Electric Motors. Rolled Steel Motors. A Complete Line of Single Phase and Three Phase Rolled Steel Motors

Your Source for a Complete Line of Electric Motors. Rolled Steel Motors. A Complete Line of Single Phase and Three Phase Rolled Steel Motors Your Source for a Complete Line of Electric Motors Rolled Steel Motors A Complete Line of Single Phase and Three Phase Rolled Steel Motors Mission Statement To provide the United States market for industrial

More information

General purpose aluminum frame motors. The right choice for efficiency and performance. SIMOTICS NEMA Low Voltage Motors.

General purpose aluminum frame motors. The right choice for efficiency and performance. SIMOTICS NEMA Low Voltage Motors. General purpose aluminum frame motors The right choice for efficiency and performance SIMOTICS NEMA Low Voltage Motors www.usa.siemens.com/motors Siemens GP100A Aluminum Frame Motors Precision construction,

More information

Motor Accessories. NEMA AC Motor C-Face Kits for Field Conversion

Motor Accessories. NEMA AC Motor C-Face Kits for Field Conversion Gearmotors and PT Components Grinders Gearmotors Servo s Mod Express Baldor Education Workshop 396 NEMA AC C-Face Kits for Field Conversion Description Type/ NOTE: NEMA BA Dimension will be non-standard

More information

SUBMERSIBLE PUMPS DRAINER SUMP/EFFLUENT

SUBMERSIBLE PUMPS DRAINER SUMP/EFFLUENT SUBMERSIBLE PUMPS DRAINER SUMP/EFFLUENT LEESON Canada features products by well known manufacturer Berkeley which includes the Toran and Simer brand names. SUBMERSIBLE UTILITY PUMPS GEYSER II 1/6 HP 1/6

More information

W21 HIGH EFFICIENCY GENERAL PURPOSE MOTORS

W21 HIGH EFFICIENCY GENERAL PURPOSE MOTORS W21 HIGH EFFICIENCY MOTORS!"#$&'#(&)*"&+,-&"./&0,,12#3&4,.5&!"00&678997:;?@&ABCD7=EF=G Data subject to change without notice. PDF processed with CutePDF evaluation edition www.cutepdf.com :7BD ROLLED

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090529 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW Line/Load Reactors are components designed to improve the

More information

SUPER-MAX INDUCTION MOTOR

SUPER-MAX INDUCTION MOTOR Compliance Certificate No.CC014A CSA Listed No. 1077944 SUPER-MAX INDUCTION MOTOR PREMIUM EFFICIENCY SERIES CSA Certified for Class I Division 2 Groups A, B, C, D T3C TOTALLY ENCLOSED FAN COOLED FRAME:

More information

Small & Medium AC General Purpose Motors. Description

Small & Medium AC General Purpose Motors. Description Totally Enclosed Fan Cooled Type CS 60 Hz 40 C Ambient Continuous Duty Class B.5 Service Factor Ball Bearing IP44 Designed for all general purpose industrial applications in a dusty, dirty and/or humid

More information

Super-E Premium Efficient Motors

Super-E Premium Efficient Motors Super-E Premium Efficient Motors Why Baldor? Customer Preference 20% 1985 50% 1990 90% 2000 94% 2003 95.5% 2007 The percentages shown reflect results of studies conducted in which Baldor was chosen as

More information

200 & 575 Volt Motors. 200 Volt, Three Phase, TEFC, Foot Mounted. 1/2 thru 50 Hp NEMA 56C thru 326T

200 & 575 Volt Motors. 200 Volt, Three Phase, TEFC, Foot Mounted. 1/2 thru 50 Hp NEMA 56C thru 326T Farm Duty 200 Volt, TEFC, Foot Mounted 200 & 7 Volt 1/2 thru 0 6C thru 26T Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200 volt power.

More information

MAX-E1 HIGH EFFICIENCY. Severe Duty

MAX-E1 HIGH EFFICIENCY. Severe Duty MAX-E1 HIGH EFFICIENCY Severe Duty DESIGN FEATURES & CONSTRUCTION ALL MAX-E1 MOTORS DELIVER THESE IMPRESSIVE DESIGN FEATURES HPE - High Pulse Endurance Wire Non-hygroscopic, Class F insulation system High-grade,

More information

CYCLO HBB. ofc. Gearmotor. Premium Efficient Motor Edition. Catalog

CYCLO HBB. ofc. Gearmotor. Premium Efficient Motor Edition. Catalog ofc CYCLO HBB HELICAL BUDDYBOX Gearmotor Premium Efficient Motor Edition Catalog 07.401.90.001 Helical Buddybox EP.NA Motors Enhanced Performance (EP.NA) integral motors represent exceptional value to

More information

X$DUltra NEMA Premium 7 Extra Severe Duty Motors Frame 3/4-250 HP

X$DUltra NEMA Premium 7 Extra Severe Duty Motors Frame 3/4-250 HP gmotors X$DUltra 7 841 NEMA Premium 7 Extra Severe Duty Motors 143-449 Frame 3/4-250 HP GE sets the standard... We are dedicated to the future. Since Edison s time at the leading edge of discovery, GE

More information

GE Energy. X$D Ultra 841. NEMA Premium Extra Severe Duty Motors Frame HP

GE Energy. X$D Ultra 841. NEMA Premium Extra Severe Duty Motors Frame HP GE Energy X$D Ultra 841 Premium Extra Severe Duty Motors 143-449 Frame 0.75-300 HP GE sets the standard with powerful features. We are dedicated to the future. Since Edison s time at the leading edge of

More information

SUB-FHP AC GEARMOTORS PARALLEL SHAFT GEARMOTORS

SUB-FHP AC GEARMOTORS PARALLEL SHAFT GEARMOTORS SUB-FHP AC GEARMOTORS PARALLEL SHAFT GEARMOTORS 12-100 In-Lbs Single phase gearmotors, totally enclosed for continuous duty, general purpose applications. Permanent TEFC split capacitor designs are rated

More information

E280 DIAMETER FRAMES

E280 DIAMETER FRAMES E28 DIAMETER FRAMES MODEL NUMBER CODE...E28 FRAME To construct a motor listing, select the combination of features required, and put all the coded information in the proper sequence. Please account for

More information

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors 1. What are the two main parts of a three-phase motor? Stator and Rotor 2. Which part of a three-phase squirrel-cage induction motor is a

More information

Premium Efficiency Exceeds Effciency Levels Mandated by CSA C390 and EPACT 92

Premium Efficiency Exceeds Effciency Levels Mandated by CSA C390 and EPACT 92 Premium Efficiency Exceeds Effciency Levels Mandated by CSA C390 and EPACT 9 Crown Triton TM Series Premium Efficiency Motors Experience Combined with Technology yundai Induction Motors use Finite Element

More information

SIMOTICS Frei verwendbar / Siemens AG Alle Rechte vorbehalten.

SIMOTICS Frei verwendbar / Siemens AG Alle Rechte vorbehalten. The most comprehensive range of motors SIMOTICS SIMOTICS portfolio Motors SIMOTICS Low voltage motors for line and inverter operation Motors for motion control application DC motors High-voltage Motors

More information

Stearns Super-Mod Totally-Enclosed Non-Ventilated (TENV) Modules Featuring

Stearns Super-Mod Totally-Enclosed Non-Ventilated (TENV) Modules Featuring TENV/IP54 Super-Mod Clutch-Brake Modules Imagine a totally-enclosed, nonventilated clutch-brake ready to work right out of the box, requiring no modifications. And at a price competitive with open enclosure

More information

Powerful + Efficient + Reliable

Powerful + Efficient + Reliable 1 THRU 50HP NEMA 140T THRU 449T HIGH EFFICIENCY ISO9001 CERTIFIED Powerful + Efficient + Reliable TEFC CAST IRON FRAMES CLASS F INSULATED 1.15 SERVICE FACTOR OVER SIZED BEARINGS LOW-LOSS ELECTRICAL GRADE

More information

Signature Series & Ultimate E Motors, High Performance & Premium Efficiency. Alum. Aluminum And Steel TEFC & ODP Motors C O M P LIA N T

Signature Series & Ultimate E Motors, High Performance & Premium Efficiency. Alum. Aluminum And Steel TEFC & ODP Motors C O M P LIA N T & Motors, High Performance & Premium Efficiency Alum. EPAct Aluminum And Steel TEFC & ODP Motors C O M P LIA N T or : High Performance and Pr Beyond Energy Efficient Lincoln and motors provide both premium

More information

Rolled Steel Motors. A Complete Line of Single Phase and Three Phase Rolled Steel Motors

Rolled Steel Motors. A Complete Line of Single Phase and Three Phase Rolled Steel Motors Rolled Steel Motors A Complete Line of Single Phase and Three Phase Rolled Steel Motors SINGLE PHASE, TEFC, 56C FRAME 1/3-2 Horse Power 1800 and 3600 RPM C-Flange with Removable Feet High Starting Torque

More information

Comfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities

Comfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities 3-35 kw 10,200-119,420 Btuh 208 to 600 Volts 1 or 3 Phase Meets NEC, OSHA and UL Requirements ATEX and GOST Models Available Refer to WR-80EP in the Controls section. F-4 Description Type is designed to

More information

Reliance Electric. Motors: The Automotive Industry Solution. Complete. Tough. Smart.

Reliance Electric. Motors: The Automotive Industry Solution. Complete. Tough. Smart. Reliance Electric Motors: The Automotive Industry Solution Complete. Tough. Smart. Complete. From parts forming, metal cutting, and assembly to the most demanding test stand applications, there is a dependable

More information

RGZESDI Inverter Duty AC Induction Motors

RGZESDI Inverter Duty AC Induction Motors November 1999 RGZESDI Inverter Duty AC Induction Motors Installation Operation Maintenance Instructions Frames: 143T through S449SS/LS SIGNAL WORDS The signal words Danger, Warning and Caution used in

More information

AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1

AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1 AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1 STANDARD AND SPECIFICATION Performance: Meet the requirement of Singapore standard

More information

Baldor Mod Express Modification Motor Mod Express Page

Baldor Mod Express Modification Motor Mod Express Page Page No. ATEX M1 Balance... 396 M1A Dynamic Balance of Rotors M2 Bearings... 396 M2A Sealed or Double Shielded M2B Ball to Roller M2C Bearing Thermocouples M2D Bearing RTD S M2E Add Double Sealed Bearings

More information

PERFORMANCE DATA 3-PHASE INDUCTION MOTOR

PERFORMANCE DATA 3-PHASE INDUCTION MOTOR ISSUED October 28, 2013 TYPE AETACF PERFORMANCE DATA 3-PHASE INDUCTION MOTOR ENCLOSURE TEFC CATALOG# GV0/74C NAMEPLATE INFORMATION OUTPUT FRAME RATED INS. POLE VOLTAGE HZ HP KW SIZE AMBIENT CLASS 3/4 0.56

More information

Application Information

Application Information AGENCY LISTINGS UL and CSA Marathon Electric s Fire Pump and Explosion Proof motors are UL Listed. Other motor types are UL Recognized, including models with inherent overheating protection as noted (i.e.

More information

Cast Iron Frame Motors For Zone 21 Improved Efficiency EFF2

Cast Iron Frame Motors For Zone 21 Improved Efficiency EFF2 Motors Energy Automation Coatings Cast Iron Frame Motors For Zone 21 Improved Efficiency EFF2 Standard Features: Three-phase, multivoltage, IP66, TEFC : 0.12 up to 250kW Frames: 63 up to 355M/L Voltage:

More information

SERIES 12 SUB-FHP RIGHT ANGLE DC GEARMOTORS

SERIES 12 SUB-FHP RIGHT ANGLE DC GEARMOTORS SERIES 12 SUB-FHP RIGHT ANGLE DC GEARMOTORS SERIES 12 SUB-FHP Electrical Specifications: Both SCR (90 volt) and Low Voltage (12 volt) right angle gearmotors. the 90 volt motors are performance matched

More information

Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código

Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código Letra de código Código de rotor bloqueado Rotor bloqueado, Letra de código kva / hp kva / hp A 0.00 3.15 L 9.00 10.00 B 3.15 3.55 M 10.00 11.00 C 3.55 4.00 N 11.00 12.50 D 4.00 4.50 P 12.50 14.00 E 4.50

More information