PROJECT DESCRIPTION. SCOPE OF WORK (28) PV MODULES (TOTAL: x,xxx SQ. FT.) (1) 7.7 kw INVERTER (2) 8.0 kw, 12.0 kwh BATTERIES

Size: px
Start display at page:

Download "PROJECT DESCRIPTION. SCOPE OF WORK (28) PV MODULES (TOTAL: x,xxx SQ. FT.) (1) 7.7 kw INVERTER (2) 8.0 kw, 12.0 kwh BATTERIES"

Transcription

1 SHEET IDEX T.0 COVER E.0 ELECTRICAL DIARAM E. ELECTRICAL CALCULATIOS E.0 SAFETY PLACARDS E3.0 ELECTRICAL DETAILS PROJECT DESCRIPTIO THIS 9.4 KWSTC, ROOF MOUTED PHOTOVOLTAIC (PV) SYSTEM IS TO BE ISTALLED AT THE SILE-FAMILY DWELLI I LA VETA, COLORADO. THE EERY PRODUCED BY THE PV SYSTEM SHALL BE ITERCOECTED WITH THE EXISTI O-SITE ELECTRICAL EQUIPMET VIA A BACK-FED BREAKER I THE MAI SERVICE PAEL. THIS PROJECT ICLUDES () EERY STORAE BATTERIES. SCOPE OF WORK (8) PV MODULES (TOTAL:, SQ. FT.) (). kw IVERTER () 8.0 kw,.0 kwh BATTERIES SITE SPECIFICATIOS OCCUPACY CATEORY: II DESI WID SPEED: 06 MPH EXPOSURE CATEORY: C OVERI CODES 0 ATIOAL ELECTRICAL CODE 05 ITERATIOAL BUILDI CODE 05 ITERATIOAL MECHAICAL CODE 0 ITERATIOAL FIRE CODE W/ COLORADO STATE BUILDIS PRORAM AMEDMETS UDERWRITERS LABORATORIES (UL) STADARDS OSHA 9 CFR COSTRUCTIO OTES.) COTRACTOR SHALL FIELD VERIFY ALL DIMESIOS PRIOR TO IITIATI COSTRUCTIO..) COTRACTOR SHALL REVIEW ALL MAUFACTURER ISTALLATIO DOCUMETS PRIOR TO IITIATI COSTRUCTIO. 3.) ALL EQUIPMET SHALL BE LISTED BY U.L. (OR EQUAL) AD LISTED FOR ITS SPECIFIC APPLICATIO. 4.) ALL EQUIPMET SHALL BE RATED FOR THE EVIROMET I WHICH IT IS ISTALLED. 5.) ALL EQUIPMET SHALL BE ISTALLED I ACCORDACE WITH THE MAUFACTURER'S ISTALLATIO ISTRUCTIOS. 6.) ACCESS TO ELECTRICAL COMPOETS OVER 50 VOLTS TO ROUD SHALL BE RESTRICTED TO QUALIFIED PERSOEL..) ALL CODUCTORS SHALL BE COPPER, RATED FOR 600 VOLTS AD 90 C WET EVIROMET, ULESS OTHERWISE OTED. 8.) WHERE S OF JUCTIO BOXES, RACEWAYS, AD CODUITS ARE OT SPECIFIED, COTRACTOR SHALL THEM ACCORDI TO APPLICABLE CODES. 9.) PV MODULE FRAMES SHALL BE BODED TO RACKI RAIL OR BARE COPPER.E.C. PER THE MODULE MAUFACTURER'S LISTED ISTRUCTIO SHEET. 0.) PV MODULE RACKI RAIL SHALL BE BODED TO BARE COPPER.E.C. VIA WEEB LU, ILSCO BL-4DBT LAY-I LU, OR EQUIVLET LISTED LU..) ROUDI ELECTRODE CODUCTOR (.E.C.) SHALL BE COTIUOUS AD/OR IRREVERSIBLY SPLICED/WELDED..) ALL JUCTIO BOXES, COMBIER BOXES, AD DISCOECTS SHALL BE ISTALLED I A ACCESSIBLE LOCATIO. 3.) ROOF ACCESS POITS SHALL BE AT A STRO POIT O THE BUILDI AD OT REQUIRE THE PLACEMET OF LADDERS OVER EXTERIOR WALL OPEIS. 4.) WORKI SPACE AROUD ELECTRIAL EQUPMET SHALL COMPLY WITH EC 0.6 LA VETA, CO kwstc,. kw AC REVISIOS DESCRIPTIO DATE REV OE LIE 6/6/0 WIRI DIARAM /0/0 A SOE ECO 4//08 B Sheet umber: T.0 ASI B - " " DESI & DRAFTI BY: RICHARD DOBBIS # PV

2 () (E) = EQUIP. ROUDI CODUCTOR = CODUCTOR =FUSE = BREAKER = EW EQUIP. = EXISTI EQUIP. = LIE (BLACK) = LIE (RED) = EUTRAL (WHITE) = ROUD (REE) = POSITIVE (RED) = EATIVE (BLACK) TA PHASE CODUCTOR QTY, AD TYPE PER CODUIT WIRE AD CODUIT SCHEDUL E ROUD CODUCTOR QTY, AD TYPE PER CODUIT CODUIT CODUIT TYPE DIST. (E) EERATOR 40 VAC, 4.0 kw EMA 3R, UL LISTED (E) CODUCTORS RATED MI. 00 A DC /STRI AW #0 PV-WIRE AW #6 BARE CU /A /A 5 DC 8 AW #0 THW- AW #0 THW- " SCH40 PVC 80 AC 3 AW #8 THW- AW #8 THW- 3/4" EMT 0 AC 3 AW #8 THW- AW #8 THW- 3/4" EMT 0 (E) MAI SERVICE PAEL 40 VAC, 00 A EMA 3R, UL LISTED WIRI OTES:.) COECTIOS LABELED "COMM." SHALL USE MI. AW #4 AD. AW #6 WIRE..) REFERECE THE SOE ISTALLATIO MAUAL FOR MORE IFORMATIO. EXISTI LOADS TYP. 00 A () MAI SERVICE DISCOECT 00 A, 40 V, -P (E) BUS BARS: 00 A LA VETA, CO 8055 () BATTERY/IVERTER ECLOSURE (QTY. ) SOE ECO OUTPUT: 8.0 kw, 40 VAC, 33.3 A (RID), 33.3 A (BACKUP) PEAK EFFICIECY: 95.0% EMA, UL LISTED, IP- RATED kwh 00 A () BATTERY 50V LI-IO, kwh () IVERTER OUTBACK POWER 8048A AC MICRORID IPUT AC () AC BATTERY BREAKER #, 40 V, -P 9.4 kwstc,. kw AC () IVERTER OUTBACK POWER 8048A () AC BATTERY BREAKER #, 40 V, -P kwh 00 A () BATTERY 50V LI-IO, kwh E AC MICRORID IPUT AC REVISIOS DESCRIPTIO DATE REV OE LIE 6/6/0 WIRI DIARAM /0/0 A SOE ECO 4//08 B STRI STRI STRI 3 STRI 4 BLD ITERIOR WALL DC () JUCTIO BOX EMA 4X, UL LISTED DC O ROOFTOP () PV IVERTER SMA SB00TL-US- OUTPUT:.68 kw, 40 VAC, 3 A 96.5% CEC-WEIHTED EFFICIECY EMA 3R, UL LISTED, ITERAL FDI & AFCI UROUDED, TRASFORMERLESS UL LISTED DC DISCOECT MPPT 'A' MPPT 'B' AC BLD EXTERIOR/ITERIOR WALL TO EERATOR AUTO-START BLD ITERIOR WALL 40 A (E) MAI BODI JUMPER PER EC 50.8 & 50.8 (E) BODI JUMPER PER EC 50.9(A)() (E) ROUDI ELECTRODE CODUCTOR PER EC 50.6, 50.64, & (E) ROUDI ELECTRODE SYSTEM PER EC () PV BREAKER 40 A, 40 V, -P ISTALLED PER EC 05.(D)()(3)(B) Sheet umber: E.0 ASI B - " " DESI & DRAFTI BY: RICHARD DOBBIS # PV

3 MPPT "A" MPPT "B" Array Configuration System: 9.4 kwstc,. kw AC Total PV Module Qty: 8 TA DC DC Inverter I.D. # Inverter AC Power (kw): PV Power (kwstc): Inverter DC:AC Ratio Module Total Qty: Inv # String Qty: String Length: Ma Open Circuit Voltage 555 Operating Voltage: 40 Ma Short Circuit Current 5. Operating Current:.4 String Qty: String Length: Ma Open Circuit Voltage 555 Operating Voltage: 40 Ma Short Circuit Current 5. Operating Current:.4 PV Module Specifications Model umber: PAASOIC VBH330SA6 Weight: 40.8 lbs Dimensions: STC: 330 Watts Voc: 69. Volts DC Vmp: 58.0 Volts DC Isc: 6.0 Amps Imp: 5.0 Amps Voc Temp Coeff: -0.5 %/ C Ma DC Voltage: 600 Volts DC Local Record Low Temp: C Data Source: 5 C - Voc Temp Coefficient Record Low Temp. PV System Maimum Voltage Calculation per EC 690.(A) -30 ALAMOSA SA LUIS VALLEY RL + = Voc Correction Factor 0.5%/ C 55 C + = = Volts DC TA ORII DESTIATIO MATERIAL TEMP. RATI (in) Voc Correction Voc Factor CODUCTOR SPECIFICATIOS 30 C PER 30.5(B)(6) Ma # of Modules in Series CURRET 690.8(A)() = Temperature Corrected Open Circuit Voltage REQUIRED CODUCTOR Isc (Amps) COMBIED STRIS = CURRET PER 5% PER 690.8(B)() Refrigerator Sq. ft. of dwelling Description W/sq. ft. of lighting Load Schedule Amps Volts Watts Hours of operation Watt-hours Lighting load calculations per EC 0.4 Hours of operation % 6400 Total watts of lighting 300 -,000 35% 0 00,00 W and 5% Total: = CURRET PER CURRET PER < 690.8(B)() 690.8(B)() DC PV STRI JUCTIO BOX COPPER 90 C AW #0 40 Amps =.6 Amps.5 = 9.5 Amps 9.5 Amps < 40.0 Amps DC JUCTIO BOX IVERTER COPPER 5 C AW #0 35 Amps =.6 Amps.5 = 9.5 Amps 9.5 Amps < 35.0 Amps TA TA AC AC EVIROMET LOCAL % AV. HIH PV Inverter Specifications Model umber: SMA SB00TL-US- Power Rating:.68 kw AC ominal Voltage: 40 Volts AC Ma Output Current: 3.0 Amps CEC Weighted Efficiency: 96.5% Maimum DC Voltage: 600 DC Start Voltage: 50 Ma. MPPT Voltage: 480 Ma Current MPPT A: 8.0 MPPT Quantity: Ma Current MPPT B:.0 Inverter Quantity: Ma Current MPPT C: /A CODUCTOR TEMPERATURE DERATI HEIHT ABOVE ROOF (in) TEMP. ADDER OPERATI PER 30.5(B)(3)(c) CORRECTIO 30.5(B)()(a) CODUIT FILL DERATI UROUDED CODUCTORS 690.8(A)() CORRECTIO 30.5(B)(3)(a) CORRECTED CALCULATIO TEMP CODUIT DERATE FILL DERATE CHECK # CODUCTOR = CODUCTOR CURRET PER < 690.8(B)() OUTDOORS, SHADED (+0 C) 9 - /A /A = 36.4 Amps.6 Amps < 36.4 Amps UDERROUD (+0 C) 9 - /A = 4.5 Amps.6 Amps < 4.5 Amps ORII DESTIATIO MATERIAL CODUCTOR SPECIFICATIOS TEMP. RATI TRADE IVERTER OUTPUT CURRET IVERTERS = 5% PER 690.8(B)() CHECK # = CURRET PER CURRET PER < 690.8(B)() 690.8(B)() AC IVERTER MAI PAEL COPPER 5 C AW #8 mps 3.0 = 3.0 Amps.5 = 40.0 Amps 40.0 Amps < mps AC SOE ECO MAI PAEL COPPER 5 C AW #8 mps 33.3 = 33.3 Amps.5 = 4.6 Amps 4.6 Amps < mps CODUCTOR TEMPERATURE DERATI EVIROMET LOCAL % AV. HIH EXPECTED OPERATI CORRECTIO 30 C PER 30.5(B)(6) CODUIT FILL DERATI UROUDED CORRECTIO CODUCTORS 30.5(B)(3)(a) Battery Inverter Specifications Model umber: SOE ECO Power Rating (W AC): 8000 Ma Utility Input Current (A): 33.3 ominal Voltage (VAC): 40 Backup Output Current (A): 33.3 DC Charge Current (A): 30 Ma Surge Current (A)*: 00 ominal Voltage (VDC): Voltage Range (VDC): CEC Efficiency: Inverter Quantity: 9.5% *Surge current is typically only seen in off-grid (backup) mode and is limited to 0ms. Consult manufacturer's specifications for more information. REQUIRED CODUCTOR CODUCTOR CURRET PER 690.8(A)(3) CORRECTED CALCULATIO CODUIT TEMP DERATE FILL DERATE = CORRECTED CURRET PER < VOLTAE DROP OE-WAY DISTACE CHECK # CODUCTOR EXT. BLD. WALL (+5 C) = 43.5 Amps 3.0 Amps < 43.5 Amps IDOORS (+0 C) = mps 33.3 Amps < 50.0 Amps CHECK # 690.8(B)() CODUCTOR VOLTAE DROP 5 ft 0.0% 80 ft.04% CORRECTED VOLTAE DROP OE-WAY DISTACE VOLTAE DROP 0 ft 0.% 0 ft 0.% DESCRIPTIO DATE REV OE LIE 6/6/0 Sheet umber: LA VETA, CO kwstc,. kw AC REVISIOS WIRI DIARAM /0/0 A SOE ECO 4//08 B E. ASI B - " " DESI & DRAFTI BY: RICHARD DOBBIS # PV

4 WARI ELECTRIC SHOCK HAZARD. DOOTTOUCH TERMIALS. TERMIALS O BOTHTHELIEADLOAD SIDES MAY BE EERIZED I THE OPE POSITIO. PHOTOVOLTAIC POWER SOURCE THIS SITE COTAIS A STAD-ALOE ELECTRICAL POWER SYSTEM. WARI IVERTER OUTPUT COECTIO. DO OT RELOCATE THIS OVERCURRET DEVICE REQ'D BY: EC 690. DISCOECTS PV LOAD CETERS COMBIER BOXES REQ'D BY: EC 690.3(E)(3) EXPOSED RACEWAYS, CABLE TRAYS COVERS OR ECLOSURES OF JUCTIO BOXES CODUIT BODY W/ AVAILABLE CODUIT OPEI REQ'D BY: EC (A) ELECTRICAL PAEL(S) 3 REQ'D BY: EC 05.(D)() PV SYSTEM BREAKER 4 LA VETA, CO 8055 SOLAR AC DISCOECT SOLAR DC DISCOECT WARI ELECTRIC SHOCK HAZARD. THE DC CODUCTORS OF THEPVSYSTEMARE UROUDED AD MAY BE EERIZED. 9.4 kwstc,. kw AC REQ'D BY: EC 690.4(C)() PV SYSTEM AC DISCOECTS 5 REQ'D BY: EC 690.3(B) PV SYSTEM DC DISCOECTS 6 REQ'D BY: EC (F) JUCTIO BOXES, COMBIER BOXES DC DISCOECTS, IVERTERS WARI IFAROUDFAULTIS IDICATED, THE ORMALLY ROUDED CODUCTORS MAY BE EERIZED AD UROUDED. REQ'D BY: EC 690.5(C) IVERTER 8 RID TIED PHOTOVOLTAIC POWER SOURCE MPPT 'A' SPECIFICATIOS: OPERATI CURRET:.4 A OPERATI VOLTAE: 40 V SYSTEM VOLTAE: 555 V SYSTEM CURRET: 5. A MPPT 'B' SPECIFICATIOS: OPERATI CURRET:.4 A OPERATI VOLTAE: 40 V SYSTEM VOLTAE: 555 V SYSTEM CURRET: 5. A IVERTER OUTPUT:. kw, 3 A, 40 VAC REQ'D BY: EC IVERTER 9 DESCRIPTIO DATE REV OE LIE 6/6/0 WIRI DIARAM /0/0 A SOE ECO 4//08 B Sheet umber: REVISIOS E.0 ASI B - " " SIAE REQUIREMETS.) RED BACKROUD.) WHITE LETTERI 3.) MI. 3/8" LETTER HEIHT 4.) ALL CAPITAL LETTERS 5.) ARIAL OR SIMILAR FOT 6.) WEATHER RESISTAT MATERIAL, PER UL 969 SCALE: " = 4" DESI & DRAFTI BY: RICHARD DOBBIS # PV

5 PV MODULE TYP. MAUFACTURER-ISTALLED PV JUCTIO BOX TYP. COIL EXCESS WIRE (WHERE REQUIRED) DO OT EXCEED WIRE BEDI RADIUS FEEDER CODUIT TYP. ECLOSURE TYP MC4 COECTOR TYP. ELECTRICAL ROUDI CODUCTOR (EC) TYP. LA VETA, CO 8055 RACKI RAIL 9.4 kwstc,. kw AC ROUD LU TYP. ROUD BUSHI TYP. MODULE SKIP STRII SCALE: TS TYPICAL EQUIPMET ROUDI SCALE: TS REVISIOS DESCRIPTIO DATE REV OE LIE 6/6/0 WIRI DIARAM /0/0 A SOE ECO 4//08 B Sheet umber: E3.0 ASI B - " " DESI & DRAFTI BY: RICHARD DOBBIS # PV

SITE SPECIFICATIONS OCCUPANCY CATEGORY: II DESIGN WIND SPEED: 110 MPH EXPOSURE CATEGORY: C GROUND SNOW LOAD: 0 PSF

SITE SPECIFICATIONS OCCUPANCY CATEGORY: II DESIGN WIND SPEED: 110 MPH EXPOSURE CATEGORY: C GROUND SNOW LOAD: 0 PSF PROJECT DESCRIPTIO THIS ROOF MOUTED PHOTOVOLTAIC (PV) SYSTEM IS TO BE ISTALLED AT THE OFFICE BUILDI I CITY, CALIFORIA. THE EERY PRODUCED BY THE PV SYSTEM SHALL BE ITERCOECTED WITH THE UTILITY RID THROUH

More information

SHEET INDEX T1.0 COVER A1.0 SITE PLAN A2.0 MOUNTING & RACKING METHOD E1.0 ELECTRICAL DIAGRAM E2.0 SAFETY PLACARDS

SHEET INDEX T1.0 COVER A1.0 SITE PLAN A2.0 MOUNTING & RACKING METHOD E1.0 ELECTRICAL DIAGRAM E2.0 SAFETY PLACARDS PV SYSTEM THIS 16.5 KWSTC, ROOF-MOUTED PHOTOVOLTAIC (PV) SYSTEM IS TO BE ISTALLED AT THE SILE-FAMILY DWELLI I FRESO CA. THE EERY PRODUCED BY THE PV SYSTEM SHALL BE ITERCOECTED WITH THE UTILITY RID THROUH

More information

COVER VICINITY MAP SCOPE OF WORK ELECTRICAL NOTES GOVERNING CODES SHEET INDEX

COVER VICINITY MAP SCOPE OF WORK ELECTRICAL NOTES GOVERNING CODES SHEET INDEX SCOPE OF WORK TO INSTALL A SOLAR PHOTOVOLTAIC (PV) SYSTEM THE POWER ENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY RID THROUH THE EXISTIN ELECTRICAL SERVICE EQUIPMENT. THE PV SYSTEM

More information

HAUL ROUTE COMMERCIAL GATE. Downs Road. Downs Road BUILDING Walkup Way EAST GATE. Walkup Way. Independence Road.

HAUL ROUTE COMMERCIAL GATE. Downs Road. Downs Road BUILDING Walkup Way EAST GATE. Walkup Way. Independence Road. unk. (BUILDIS 008, 00, 007, 08, 07, 0, 0, 07, 0880, 0 & 07) 7 8 BUILDI 0 LIFT STATIO 07 0 0 0 US8 08 McIntosh Court Hume Drive 8 08 8 08 08 08 08 0 7 7 0 00 07 08 Harrison Drive 087 Red Horse Road Walters

More information

BATTERY CHARGING GUIDE

BATTERY CHARGING GUIDE BATTERY CHARI UIDE For rid-connected and Off-rid Systems 2012 Southwest Windpower, Inc. All Rights Reserved Building a Battery Charging/Battery Backup System Using the Skystream 3.7 wind generator, you

More information

Solar Eligibility Checklist for Expedited Photovoltaic Permitting for One- and Two-Family Dwellings

Solar Eligibility Checklist for Expedited Photovoltaic Permitting for One- and Two-Family Dwellings Solar Eligibility Checklist for Expedited Photovoltaic Permitting for One and TwoFamily Dwellings GEERAL REQUIREMETS A. System size is 10 kw AC CEC rating or less B. System is located in an area with a

More information

CITY OF SOUTH HAVEN CITY OF SOUTH HAVEN 539 PHOENIX ST. SOUTH HAVEN, MI SHEET INDEX CITY OF SOUTH HAVEN OFFICIALS LOCAL UTILITIES

CITY OF SOUTH HAVEN CITY OF SOUTH HAVEN 539 PHOENIX ST. SOUTH HAVEN, MI SHEET INDEX CITY OF SOUTH HAVEN OFFICIALS LOCAL UTILITIES CITY OF SOUTH HAVE CITY OF SOUTH HAVE OFFICIALS CITY OF SOUTH HAVE 539 PHOEIX ST. SOUTH HAVE, MI 49090 LOCAL UTILITIES SHEET IDEX 1 TITLE SHEET 2 DETAILS AD EERAL OTES 3 REMOVALS PROJECT LOCATIO AS: ELECTRIC:

More information

33'-10"± ROOF #1 (2) SUNPOWER SPR E C-AC MICROINVERTER MODULES ROOF #2 (13) SUNPOWER SPR E C-AC MICROINVERTER MODULES 78'-9"± 25'-5"

33'-10± ROOF #1 (2) SUNPOWER SPR E C-AC MICROINVERTER MODULES ROOF #2 (13) SUNPOWER SPR E C-AC MICROINVERTER MODULES 78'-9± 25'-5 PROJECT : 15 x 327 SUNPOWER SPR E20-327-C-AC MICROINVERTER MODULES ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES SYSTEM SIZE: 4.90 kw DC STC ARRAY AREA #1: 35.08 SQ FT. ARRAY AREA #2: 228.02 SQ FT. SUMMARY 15

More information

Solar PV Standard Electrical Plan

Solar PV Standard Electrical Plan *** Provide this document to the inspector along with ALL system installation instructions *** Project Address: Permit Number: SCOPE: Standard plan for installation of solar PV systems utilizing 2 wire

More information

Solar PV Standard Electric Plan

Solar PV Standard Electric Plan *** Provide this document to the inspector along with ALL system installation instructions *** SCOPE: Standard plan for the installation of microinverter solar PV systems, not exceeding a total AC output

More information

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings TOOLKIT DOCUMENT #4 Solar Standard Plan Simplified Microinverter and M Systems for One- and Two-Family Dwellings SCOPE: Use this plan ONLY for systems using utility-interactive Microinverters or Modules

More information

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings TOOLKIT DOCUMENT #4 Your City logo here Solar Standard Plan Simplified Microinverter and M Systems for One- and Two-Family Dwellings SCOPE: Use this plan ONLY for systems using utility-interactive Microinverters

More information

Solar PV Standard Plan Simplified Microinverter and ACM Systems for Oneand Two-Family Dwellings

Solar PV Standard Plan Simplified Microinverter and ACM Systems for Oneand Two-Family Dwellings County of Santa Barbara Your City logo here Solar Standard Plan Simplified Microinverter and M Systems for Oneand Two-Family Dwellings SCOPE: Use this plan ONLY for systems using utility-interactive Microinverters

More information

2016 Photovoltaic Solar System Plan Review List

2016 Photovoltaic Solar System Plan Review List Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Photovoltaic Solar System Plan Review List GENERAL PROJECT INFORMATION PLAN CHECK NO DATE JOB ADDRESS CITY ZIP REVIEWED BY PHONE

More information

AED-N Electrical Design Requirements

AED-N Electrical Design Requirements US Army Corps of Engineers Afghanistan Engineer District - orth AED- Electrical Design Requirements Various Locations, Afghanistan 27 July 11 Electrical Design Requirements Table of Contents 1. eneral

More information

SOLAR PV STANDARD PLAN - COMPREHENSIVE Central/String Inverter Systems for One and Two Family Dwellings

SOLAR PV STANDARD PLAN - COMPREHENSIVE Central/String Inverter Systems for One and Two Family Dwellings SCOPE: Use this plan ONLY for utility-interactive central/string inverter systems not exceeding a total combined system ac inverter output rating of 10kW on the roof of a one- or two-family dwelling or

More information

STREAMLINED SOLAR CHECKLIST Owner Name:

STREAMLINED SOLAR CHECKLIST Owner Name: STREAMLINED SOLAR CHECKLIST Owner Name: Address: DEPARTMENT OF PUBLIC WORKS AND PLANNING ALAN WEAVER, DIRECTOR This checklist must be completed by the contractor or an authorized agent of the contractor

More information

Applicant and Site Information Job Address: Permit #:

Applicant and Site Information Job Address: Permit #: TOOLKIT DOCUENT #4 Planning and Building Services Solar Standard Plan Simplified icroinverter and Systems (One- and Two-Family Dwellings) SCOPE: Use this plan ONLY for systems using utility-interactive

More information

City of Manhattan Beach Community Development

City of Manhattan Beach Community Development City of Manhattan Beach Community Development Phone: (310) 802-5500 FAX: (310) 802-5501 TDD: (310) 546-3501 Photovoltaic Solar Panel Plan Check Guidelines Updated: 10-01-15 ORDINANCE NO. 15-0022 MBMC 9.06

More information

For Installers. Installation Manual Hybrid Solar Inverter (5.5 kw) (For Outdoor Installation) Table of Contents

For Installers. Installation Manual Hybrid Solar Inverter (5.5 kw) (For Outdoor Installation) Table of Contents For Installers Installation Manual Hybrid Solar Inverter (5.5 kw) (For Outdoor Installation) Product umber : THD-S55P3BB-US : THD-S55P3B-US The content in this Installation Manual is meant for installers.

More information

Inspector Training Workshops Module One Photovoltaic Labeling based on 2008 NEC

Inspector Training Workshops Module One Photovoltaic Labeling based on 2008 NEC Inspector Training Workshops Module One Photovoltaic Labeling based on 2008 NEC NJCE Market Manager HW Construction Department Wayne, NJ Robert A. Menist Contents Site inspections with attention on Labeling

More information

4040SE Series. Features E15. Special Templates. Certifications. Cover

4040SE Series. Features E15. Special Templates. Certifications. Cover Features The 4040SE SENTRONIC is a heavy duty, o-haded, osized closer/holder desiged to provide sigle poit hold-ope for fire ad smoke barrier doors. The door is held ope util curret iterruptio releases

More information

City of Manhattan Beach Community Development

City of Manhattan Beach Community Development City of Manhattan Beach Community Development Phone: (310) 802-5500 FAX: (310) 802-5501 TDD: (310) 546-3501 Photovoltaic Solar Panel Plan Check Guidelines Updated: 12-20-16 ORDINANCE NO. 15-0022 MBMC 9.06

More information

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings Your City logo here Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings SCOPE: Use this plan ONLY for utility-interactive central/string inverter systems

More information

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings PV TOOLKIT DOCUMENT #3 Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings SCOPE: Use this plan ONLY for utility-interactive central/string inverter systems

More information

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

More information

2030 Series. Mounting details. Concealed Mounting. Butt Hinges

2030 Series. Mounting details. Concealed Mounting. Butt Hinges Features The cocealed 2030 PACER is a heavy duty closer desiged to fit i a arrow, miimum 1-3/4 alumium trasom. The sigle lever arm ad roller assembly provide smooth, quiet door cotrol ad the choice of

More information

Air Quality Solutions

Air Quality Solutions Air Quality Solutios Istallatio & Maiteace Maual Model: IAQ350XL Air Measurig Louver with Itegral Damper II-IAQ350XL-814/New ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE OR OBLIGATION

More information

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings TOOLKIT DOCUMENT #4 Your City logo here Solar Standard Plan Simplified Microinverter and M Systems for One- and Two-Family Dwellings SCOPE: Use this plan ONLY for systems using utility-interactive Microinverters

More information

RGS PV-000. Sheet List

RGS PV-000. Sheet List 007 ANSI Full Bleed B (.00 X 7.00 Inches) 07-0-08 Scope of Work: Energy shall install a 6.600 kw Grid-tied Photovoltaic ("PV") System totaling () Silfab SLA 00 M Modules with () Enphase Energy M0-60-LL-S

More information

Roof Top Solar Permit Document 1 Submittal Requirements Bulletin. Solar Photovoltaic Installations 10 kw or Less in One- and Two-Family Dwellings

Roof Top Solar Permit Document 1 Submittal Requirements Bulletin. Solar Photovoltaic Installations 10 kw or Less in One- and Two-Family Dwellings Roof Top Solar Permit Document 1 Submittal Requirements Bulletin Small Town with a Big Backyard! Solar Photovoltaic Installations 10 kw or Less in One and TwoFamily Dwellings This information bulletin

More information

Solar Photovoltaic Power. Overarching Objectives. How many questions? 9/16/2012. From plan review to Final Inspection

Solar Photovoltaic Power. Overarching Objectives. How many questions? 9/16/2012. From plan review to Final Inspection Solar Photovoltaic Power From plan review to Final Inspection Overarching Objectives A understandable and predictable process for both the Installer and the Inspector. The installation of safe, efficient,

More information

F E A T U R E S & B E N E F I T S

F E A T U R E S & B E N E F I T S Architectural Alumium Raceway AL5200 Series Alumium Raceway is sleek, clea ad attractive. Itegrated ito casework or lab furiture, or istalled as baseboard, these raceways ca be used to distribute commuicatio

More information

XXX RESIDENCE : XXX kw DC GROUND MOUNTED PHOTOVOLTAIC SYSTEM

XXX RESIDENCE : XXX kw DC GROUND MOUNTED PHOTOVOLTAIC SYSTEM EQUIPMENT SUMMARY 36 NO'S - LG 335N1C-A5 335W MODULE 01 NO'S - OUTBACK RADIAN GS8048A INVERTER XXX RESIDENCE : XXX 12.06 kw DC GROUND MOUNTED PHOTOVOLTAIC SYSTEM SHEET INDEX T-01 COVER SHEET G-01 GENERAL

More information

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems COUNTY OF SANTA CRUZ PLANNING DEPARTMENT 701 OCEAN STREET, 4 th FLOOR, SANTA CRUZ, CA 95060 (831) 454-2580 FAX: (831) 454-2131 TDD: (831) 454-2123 KATHLEEN MOLLOY PREVISICH, PLANNING DIRECTOR Photovoltaic

More information

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST The following checklist is an outline of the general requirements found in the 2005 National Electrical Code (NEC) Article 690 for Photovoltaic

More information

Air Quality Solutions

Air Quality Solutions Air Quality Solutios Istallatio & Maiteace Maual Model: IAQ350XL Air Measurig Louver with Itegral Damper II-IAQ350XL-818/ ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE OR OBLIGATION

More information

Green Building Technology

Green Building Technology Green Building Technology Renewable Energy Sources and Design/Specification Guidelines Presented by: Kurt Uhlir & Brian Kustwin Why Renewables? Reduction of SO 2 and NOX along with greenhouse gases such

More information

SERIES 35-60J. 24 VAC Microprocessor Based Direct Spark Ignition Control Johnson Controls G76x Series Replacement FEATURES

SERIES 35-60J. 24 VAC Microprocessor Based Direct Spark Ignition Control Johnson Controls G76x Series Replacement FEATURES SERIES 35-60J 24 VAC Microprocessor Based Direct Spark Igitio Cotrol Johso Cotrols G76x Series Replacemet 35-60J FEATURES Drop-i replacemet for JCI G76x series Safe Start ad full-time flame sesig Custom

More information

AVF-5000 Motorized Valve

AVF-5000 Motorized Valve VF-5000 Motorized Valve PN16 Flaged pplicatio VF-5000 series motorized valves are composed of the electric actuators ad the cotrol valves. They are widely applied to regulate the flow of coolig /hot water

More information

CITY OF LANCASTER SPV TOOLKIT DOCUMENT #1

CITY OF LANCASTER SPV TOOLKIT DOCUMENT #1 CITY OF LANCASTER SPV TOOLKIT DOCUMENT #1 Submittal Requirements Bulletin Solar Photovoltaic Installations 10 kw or Less in One- and Two-Family Dwellings This information bulletin is published to guide

More information

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE 2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE PAGE 1 OF 5 This Reference provides a very comprehensive list of aspects of a solar PV installation that could be reviewed, clarifying

More information

SAMPLE PERMIT APPLICATION PACKAGE

SAMPLE PERMIT APPLICATION PACKAGE 2013 Lennox Industries Inc. Dallas, Texas, USA SOLAR - KIT / ACCESSORIES 507154-01 3/2013 Supersedes 506555-01 LITHO U.S.A. SAMPLE PERMIT APPLICATION PACKAGE SUNSOURCE HOME ENERGY SYSTEM SAMPLE PERMIT

More information

Factory Sealed Panelboards

Factory Sealed Panelboards FACTORY SEALED PAELBOARDS Factory Sealed Designed for use In Class I, Division 2 and Class I, Zone 2 areas such as petroleum refineries, chemical or petrochemical facilities, the factory sealed panelboards

More information

Code Calculations. for an Off-Grid PV System

Code Calculations. for an Off-Grid PV System Code Calculations for an Off-Grid PV System John Wiles Sponsored by the Photovoltaic Systems Assistance Center, Sandia National Laboratories Judy LaPointe s home is on its way to becoming a finished, off-grid

More information

DLRO100H, DLRO100HB Megger Digital Low Resistance Ohmmeters

DLRO100H, DLRO100HB Megger Digital Low Resistance Ohmmeters 99 Washigto Street Melrose, MA 02176 Phoe 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmetdepot.com DLRO100H, DLRO100HB Megger Digital Low Resistace Ohmmeters DLRO100H, DLRO100HB Megger

More information

STG Donaclone Air Cleaner

STG Donaclone Air Cleaner STG Doacloe: Field Prove ad Reliable Heavy-Duty Workhorse for Costructio & Off-Highway Applicatios That Doaldso's STG Doacloe is arguably the most commoly used air cleaer, o the widest variety of heavy-duty

More information

PHOTOVOLTAIC SYSTEMS

PHOTOVOLTAIC SYSTEMS PV WORKSHEET STANDARD STRING ARRAY Solar photovoltaic (PV) systems have widely gained acceptance as an alternative energy source. Installations range from small arrays supplying bus stop luminaires to

More information

Cable Cleats. Trefoil Cable Cleat with LSF Pad. 55mm N-2

Cable Cleats. Trefoil Cable Cleat with LSF Pad. 55mm N-2 Eato N-1 B-Lie series Cable Tray Systems Trefoil Cable Cleat with LSF Pad 1. Recommeded for istallatios where the highest levels of short circuit withstad are required. 2. Short circuit curret tested i

More information

Datasheets. Residential On-Grid Photovoltaic System Kits

Datasheets. Residential On-Grid Photovoltaic System Kits Datasheets Residential On-Grid Photovoltaic System Kits Symtech Solar Product Line 1 RESIDENTIAL 0.5kW / 1.5kW / 2kW / 3kW / 4kW / 5kW / 10kW Product Description Symtech Solar s Residential Solar PV Kits

More information

RFQ-YEM Solar Lighting System for UNDP

RFQ-YEM Solar Lighting System for UNDP AMENDMENT 1 for RFQ-YEM-0076-2016 Solar Lighting System for UNDP This Amendment is issued after the Pre-bid meeting and site visit arranged as mentioned on the RFQ docs and the results as following: To

More information

3.6 Kwp Solar system Supply, Installation, Commissioning & Maintenance of Solar Systems to YEMAC office in HADDA street, Sana a city

3.6 Kwp Solar system Supply, Installation, Commissioning & Maintenance of Solar Systems to YEMAC office in HADDA street, Sana a city LOT1 3.6 Kwp Solar system Supply, Installation, Commissioning & Maintenance of Solar Systems to YEMAC office in HADDA street, Sana a city 1 LOT 1 3.6 Kwp Solar PV Power Solution with Battery Backup Table

More information

COOPER LIGHTING - LUMARK INDUSTRIAL OPTIONS

COOPER LIGHTING - LUMARK INDUSTRIAL OPTIONS INDUSTRIAL OPTIONS + ACCESSORIES INDUSTRIAL OPTIONS RM Remote Mout max. 16.5" w/sa18 max. 20.5" w/sa23 SS Space Saver max. 21" w/sa18 max. 25" w/sa23 Q Quartz Restrike SCF 3' Safety Cable, Housig to Ceilig

More information

Solar Rooftop Photovoltaic Installations 10 kw or Less in One- and Two-Family Dwellings

Solar Rooftop Photovoltaic Installations 10 kw or Less in One- and Two-Family Dwellings Solar Rooftop Photovoltaic Installations 10 kw or Less in One- and Two-Family Dwellings This information bulletin is published to guide applicants through a streamlined permitting process for rooftop solar

More information

Onecharge Electric Vehicle Charging Unit

Onecharge Electric Vehicle Charging Unit Oecharge Electric Vehicle Chargig Uit Itelliget Sigle Outlet Desiged for destiatio chargig, this stylish ad uobtrusive chargig uit is our quickest ad most cost effective charger to istall. Perfect for

More information

SSG Donaclone Air Cleaner

SSG Donaclone Air Cleaner Desiged for the Worst Dust Coditios New Choice for Costructio ad Off-Highway Applicatios The SSG Air Cleaer offers desig improvemets ad therefore replaces our older SRG Air Cleaer models. SRG Model G0008

More information

Series HEV: control. Intro to parallel and series/parallel HEV architectures. CU Boulder ECEN5017, USU ECE

Series HEV: control. Intro to parallel and series/parallel HEV architectures. CU Boulder ECEN5017, USU ECE Series HEV: cotrol Itro to parallel ad series/parallel HEV architectures CU Boulder ECEN507, USU ECE 6930 ICE Efficiecy Map (example) CU Boulder ECEN507, USU ECE 6930 ON/OFF ICE Cotrol Strategy ( Thermometer

More information

Aluminum Center Break Switch Switch Types CB-A, CB-AV 69 kv kv n 1200A A

Aluminum Center Break Switch Switch Types CB-A, CB-AV 69 kv kv n 1200A A Bulleti DB-12B18 Alumium eter Break Switch Switch Types B-A, B-AV 9 kv - 20 kv A - A 14000 Rt., Trafford, PA 15085 p 24-84-41 f 24-84-9040 e sales@cleaveladprice.com w cleaveladprice.com Type B-A Switch

More information

First Responder System Identification Quiz. Presented by the NY-SUN PV Trainers Network

First Responder System Identification Quiz. Presented by the NY-SUN PV Trainers Network First Responder System Identification Quiz Presented by the NY-SUN PV Trainers Network SYSTEM 1 Questions: 1) Is there a solar electric system at the site? 2) What is your next step? SYSTEM 1 3) Given

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS PowerSwitch Enclosed Disconnect Switch with Receptacle (EDSR) Cat. o. EDSR Rated: 30A-600VAC Max. ISTALLATIO ISTRUCTIOS DI-000-0EDSR-00A EDSR Enclosed Disconnect Switch with Receptacle (Figure 4) OTE:

More information

Built with. Donaldson. Technology.

Built with. Donaldson. Technology. EPB ERB2 Air Cleaer Primary Dry RadialSeal Air Cleaers which offer improved reliability ad durability, reduced weight ad costs ad better serviceability. The EPB-ERB2 Primary Dry RadialSeal Air Cleaers

More information

DuraLite ECB, ECC, ECD Air Cleaner

DuraLite ECB, ECC, ECD Air Cleaner Air Cleaer Coveiet DuraLite Disposables Rugged Air Cleaers for Small ad/or High Pulsatio Gas & Diesel Egies The DuraLite Air Cleaers are disposable, oe-stage, dry air cleaers which are used o light-duty

More information

Photovoltaic Solar Plan Review

Photovoltaic Solar Plan Review PAIGE B. VAUGHAN, CBO Director of Building and Safety Phone (310) 605-5509 Fax Line (310) 605-5598 E-mail:lbutler@comptoncity.org Building & Safety Department Photovoltaic Solar Plan Review Plan Check

More information

LOT Kwp Solar PV Power Solution with Battery Backup

LOT Kwp Solar PV Power Solution with Battery Backup LOT 3 1.2 Kwp Solar PV Power Solution with Battery Backup Supply, Installation, Commissioning & Maintenance of Solar Systems to Veterinary Laboratory in Sherton street, Sana a city No. Item Description

More information

2012 DFW Solar Home Tour October 6, 2012 Reference Solar PV

2012 DFW Solar Home Tour October 6, 2012 Reference Solar PV October 6, 2012 Reference Bill Neukranz bneukranz@verizon.net 972-516-0909 10/6/12 Bill Neukranz - 2012 1 The Basics Grid Tied, No Batteries Power grid Solar panels Electric meter AC loads DC to AC Converter

More information

Smaller, Lightweight Alternative Two-Stage Air Cleaner Designed for horizontal installation

Smaller, Lightweight Alternative Two-Stage Air Cleaner Designed for horizontal installation FKB Air Cleaer Smaller, Lightweight Alterative Two-Stage Air Cleaer Desiged for horizotal istallatio The FKB series is a family of twostage air cleaers for medium dust coditios. Compared to other air cleaer

More information

powerswitch Industrial Switches & Motor Controls

powerswitch Industrial Switches & Motor Controls powerswitch Idustrial Switches & Motor Cotrols INDUSTRIAL SWITCHES & MOTOR CONTROLS levito.com/powerswitch powerswitch Idustrial Switches & Motor Cotrols Desiged for the most extreme eviromets, we kow

More information

CITY OF SONOMA - TOOLKIT DOCUMENT #1

CITY OF SONOMA - TOOLKIT DOCUMENT #1 CITY OF SONOMA - TOOLKIT DOCUMENT #1 Submittal Requirements for Solar Photovoltaic Installations 10 kw or Less in One- and Two-Family (Duplex) Dwellings This information bulletin is published to guide

More information

Pika Energy Island Made in America

Pika Energy Island Made in America Pika Energy Island Solar plus storage, clean and simple. designed in Maine Made in America control solar, batteries and local loads with one inverter The Pika Energy Island Optimized Solar Battery Inverter

More information

The following permits are required to install a solar PV system with a maximum power output of 10 kw or less:

The following permits are required to install a solar PV system with a maximum power output of 10 kw or less: Effective Date January 1, 2017 Form 1 Submittal Requirements Bulletin This information bulletin is published to guide applicants through a streamlined permitting process for solar photovoltaic (PV) projects

More information

HI-PRODUCTIVITY WELDING SYSTEMS. Increase Arc Time 15-30%

HI-PRODUCTIVITY WELDING SYSTEMS. Increase Arc Time 15-30% HI-PRODUCTIVITY WELDING SYSTEMS Icrease Arc Time 15-30% Advaced Mig Weldig System The WELDPRO 360 Mig Weldig System is a comprehesive weldig boom, desiged to miimize o-arc time activities. Arc-O time gais

More information

DUAL/TRIPLE MPPT INVERTER / CHARGER. User Manual

DUAL/TRIPLE MPPT INVERTER / CHARGER. User Manual DUAL/TRIPLE MPPT IVERTER / CHARGER User Manual Table Of Contents ABOUT THIS MAUAL... 1 Purpose... 1 Scope... 1 SAFETY ISTRUCTIOS... 1 ITRODUCTIO... 2 Features... 2 Basic System Architecture... 2 Product

More information

Cover. Fasteners Mounting. Arms Finishes/Colors/ Powder Coat

Cover. Fasteners Mounting. Arms Finishes/Colors/ Powder Coat Features The 4050T cast alumium heavy duty track closer is desiged for rugged high frequecy traffic areas. Ideal for commercial buildig applicatios ad competitive specificatio situatios that demad a combiatio

More information

SOLAR PV INSTALLATIONS

SOLAR PV INSTALLATIONS Winnipeg Information Bulletin 2016-003-B/E/S/Z SOLAR PV INSTALLATIONS An Information Bulletin is currently being created for City of Winnipeg guidelines for Solar PV Installations and will be published

More information

User Manual 3KVA/5KVA 24V INVERTER / CHARGER. Version: 1.1

User Manual 3KVA/5KVA 24V INVERTER / CHARGER. Version: 1.1 User Manual 3KVA/5KVA 24V IVERTER / CHARGER Version: 1.1 Table Of Contents ABOUT THIS MAUAL... 1 Purpose... 1 Scope... 1 SAFETY ISTRUCTIOS... 1 ITRODUCTIO... 2 Features... 2 Basic System Architecture...

More information

Residential Photovoltaic (PV) Packet

Residential Photovoltaic (PV) Packet Development Services Department Building Division 311 Vernon Street Roseville, California 95678-2649 (916) 774-5332 Fax (916) 774-5394 Residential Photovoltaic (PV) Packet The Roseville Municipal Code

More information

User Manual 3KVA/5KVA INVERTER / CHARGER. Version: 1.1

User Manual 3KVA/5KVA INVERTER / CHARGER. Version: 1.1 User Manual 3KVA/5KVA IVERTER / CHARGER Version: 1.1 Table Of Contents ABOUT THIS MAUAL... 1 Purpose... 1 Scope... 1 SAFETY ISTRUCTIOS... 1 ITRODUCTIO... 2 Features... 2 Basic System Architecture... 2

More information

RESIDENTIAL PHOTOVOLTAIC (PV) PACKET

RESIDENTIAL PHOTOVOLTAIC (PV) PACKET Public Works Building Inspection 311 Vernon Street Roseville, California 95678-2649 916.774.5332 fax 916.774.5394 RESIDENTIAL PHOTOVOLTAIC (PV) PACKET Contents of packet: Photovoltaic Checklist (2 pages

More information

SR 453 (WEKIVA PARKWAY) FROM SYSTEM INTERCHANGE TO SR 46

SR 453 (WEKIVA PARKWAY) FROM SYSTEM INTERCHANGE TO SR 46 BEE LIE IDEX OF LIGHTIG PLAS L-1 KEY L-2 & L-3 TABULATIO OF QUATITIES L-4 PROJECT OTES L-5 POLE DATA & LEGED L-6 SIG & UDERDECK LUMIAIRE DATA L-7 TO L-20 LIGHTIG PLA S L-21 TO L-23 UDERDECK LIGHTIG PLA

More information

2. Fire Department Inspections are required and available by appointment on Tuesdays and Wednesdays. See item number four for fees.

2. Fire Department Inspections are required and available by appointment on Tuesdays and Wednesdays. See item number four for fees. Instructions 1. Fire Department Over the counter Plan checks are optional for solar systems complying with 2015 California Solar permitting guidebook. Although they are optional, they are highly recommended

More information

Submittal Requirements Bulletin Solar Photovoltaic Installations 10 kw or Less in One- and Two-Family Dwellings

Submittal Requirements Bulletin Solar Photovoltaic Installations 10 kw or Less in One- and Two-Family Dwellings TOOKIT DOCUMENT #1 Submittal Requirements Bulletin Solar Photovoltaic Installations 10 kw or Less in One- and Two-Family Dwellings This information bulletin is published to guide applicants through a streamlined

More information

RELIANCE G5200 SERIES RETAIL MECHANICAL DISPENSERS

RELIANCE G5200 SERIES RETAIL MECHANICAL DISPENSERS RELIANCE G5200 SERIES RETAIL MECHANICAL DISPENSERS 2 Waye Waye Reliace G5200 Series Retail Mechaical Dispesers Desiged to deliver reliable, log-term retail fuelig performace i the harshest eviromets, the

More information

Installation and Operations Manual

Installation and Operations Manual Installation and Operations Manual 11343 REVA IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS 2071 Ringwood Ave, Unit C, San Jose, CA 95131 888-395-2248 This Manual contains important instructions

More information

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly. SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS (ELEC) This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

More information

AUTOMATIC BATTERY CHARGER

AUTOMATIC BATTERY CHARGER AUTOMATIC BATTERY CHARGER SAMLEX AMERICA. MODELS SEC - 1215A SEC - 1230A SEC - 2415A OWNER'S MANUAL Please read this maual before operatig your charger. Cotets SAFETY, INPUT VOLTAGE SELECTION... 1 INTENDED

More information

Rotary Screw Compressors R-Series 5-11 kw (5-15 hp) Fixed and Variable Speed Drives

Rotary Screw Compressors R-Series 5-11 kw (5-15 hp) Fixed and Variable Speed Drives Rotary Screw Compressors R-Series 5-11 kw (5-15 hp) Fixed ad Variable Speed Drives Compact Performace Where You Need It The affordable Igersoll Rad R-Series 5-11 kw compressor exteds the R-Series family

More information

SF6 insulated Ring Main Units and Compact Switchgear SafeRing and SafePlus For safe and reliable power distribution

SF6 insulated Ring Main Units and Compact Switchgear SafeRing and SafePlus For safe and reliable power distribution SF6 isulated Rig Mai Uits ad Compact Switchgear SafeRig ad SafePlus For safe ad reliable power distributio ABB a global leader ABB is a global leader i power ad automatio techologies that eable idustrial

More information

INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL

INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL Photovoltaic (PV) Residential Page 1 of 10 Revision Date: 07/18/2018 INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL INSPECTION CODE: 703 SCOPE: RESIDENTIAL APPLICABLE CODES: 2016 CBC, CRC, CPC,

More information

Wind Energy System.

Wind Energy System. Wind Energy System www.theoenv.com Wind Turbine System A wind turbine is using aerodynamic effect to rotate blades and transform wind into mechanical energy, the mechanical energy then transformed into

More information

SIMPLIFIED CHOICE AND A COMPLETE RANGE,

SIMPLIFIED CHOICE AND A COMPLETE RANGE, SIMPLIFIED CHOICE AND A COMPLETE RANGE, Catalogue umber = Nedbox cabiet supplied complete: Flush-moutig box for masory or dry partitios, chassis, termial block ad door Rigid flush-moutig box Chassis ad

More information

CHAPTER 10 ELECTRICAL. Notes:

CHAPTER 10 ELECTRICAL. Notes: CHAPTER 10 ELECTRICAL 1001.0 General Requirements. Electrical wiring and equipment shall comply with the requirements of NFPA 70, National Electrical Code (NEC), or local ordinances. 1002.0 Solar Photovoltaic

More information

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST The following checklist is an outline of the general requirements found in the 1999 National Electrical Code (NEC) Article 690 for Photovoltaic (PV) Power

More information

Solar Standard Plan Simplified Systems for - and Two-Family Dwellings

Solar Standard Plan Simplified Systems for - and Two-Family Dwellings Solar Standard Plan Simplified Systems for and TwoFamily wellings SCOPE: Use this plan ONLY for electrical review of utility central/string inverter systems not exceeding a system AC inverter output rating

More information

E-SERIES RESIDENTIAL SOLAR PANELS

E-SERIES RESIDENTIAL SOLAR PANELS APPLIES TO: SPR-E20-327, SPR-E19-320, SPR-E18-305, SPR-E20-245, SPR-E19-235 TESTS AND CERTIFICATIONS WARRANTY, IMPACT RESISTANCE, FUSE RATING, J-BOX Standard tests UL 1703 (Type 2 UL Fire Rating), IEC61215,

More information

My Home Solar PhotoVoltaic (PV) System 2010 through 2017 How s It Doing?

My Home Solar PhotoVoltaic (PV) System 2010 through 2017 How s It Doing? July 8th, 2017 My Home Solar PhotoVoltaic (PV) System 2010 through 2017 How s It Doing? Bill Neukranz bneukranz@verizon.net 214-876-6647 09/15/18 Bill Neukranz - 2018 1 My System: Grid Tied, No Batteries,

More information

Technical specifications

Technical specifications KINGDOM OF SAUDI ARABIA THE SAUDI FUND FOR DEVELOPMENT ( SFD) ITB -207-7 Technical specifications Project name: Reconstruction, Furniture and Equipping of Three Schools Photovoltaic Solar System for Holly

More information

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual Combiner Box Installation & Operations Manual SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual TABLE OF CONTENTS Notices and Safety Precautions Pages 1-2 Combiner

More information

Micro3 Grid Tied Residential Package

Micro3 Grid Tied Residential Package Micro3 Grid Tied Residential Package List Price: $6,616.99 Our Price: $5,906.60 Save: $710.39 Model: Micro3 Grid-Tied Package Brand: Greener Energy Our Code: KITONGRIM3 This item is a package made up of

More information

Technical Information

Technical Information Techical Iformatio Istallatio Istructios.... 420 Safety Precautios.... 42 Adapter Flage s.... 422-425 Selectio Flow Charts.... 426-427 lie Sizig ad Selectio Tool.... 428-429 48 49 Istallatio Istructios

More information

X-SERIES SOLAR PANELS

X-SERIES SOLAR PANELS [Type text] X-SERIES SOLAR PANELS UNMATCHED PERFORMANCE, RELIABILITY & AESTHETICS 21.5% efficiency Ideal for roofs where space is at a premium or where future expansion might be needed. Maximum performance

More information