1 February 17, 2015 File: Village of Valemount Box 168, 735 Cranberry Lake Road Valemount, BC V0E 2Z0 Attention: Anne Yanciw, CAO RE: Lift Station Upgrade Cost Estimates The Village of Valemount operates nine sanitary lift stations as components of the Village s sanitary sewer collection system. Four of the lift stations have been in operation since the early 1980 s, and require upgrades or replacement. The lift stations are not equipped with standby power, consequently sewage pumping service is lost during power outages, and a high degree of operator intervention is required to prevent sewage backup in the collection system. The proposed upgrades will help to provide uninterrupted service to the Village, increased capacity, and improved operations, and reduced risk of failure with the installation of: Replacement of Fifth Avenue lift station; Mechanical upgrades; Standby power supply; Upgraded electrical service and kiosk; Upgrades to programming and SCADA. The attached cost estimate is based on: Electrical upgrades proposed in the Village of Valemount 2008 SCADA System report; Extension of sanitary sewer to the west side of Highway 5; Recommendations from Village operations staff; Increased demand based on future demands to the system. The following upgrades are proposed at each site: Fifth Avenue Lift Station New lift station with increased capacity to meet future demands; Cost $799, St. Paul Street, Kamloops, BC V2C 6G4 T:

2 Date: February 17, 2015 File: Attention: Anne Yanciw, CAO Page: 2 of 3 Elm Street Lift Station Costs $202,000 Seventeenth Avenue Lift Station Internal Piping Upgrades; Infiltration Remediation; Cost $345,000 Dogwood Lift Station Internal Piping Upgrades; Cost $264,000 Cranberry Place Lift Station Costs $164,000 Canoe View Lift Station Costs $149,000 Village Office Lift Station Costs $149,000

3 Date: February 17, 2015 File: Attention: Anne Yanciw, CAO Page: 3 of 3 The total budget estimate for the identified work is $2,072,000, which includes a 30% Contingency and a 15% Engineering allowance. Moving forward, we would be happy to provide assistance with detailed design and implementation of the proposed upgrades when the Village plans to move forward with the much needed upgrades. Please let us know if you have any questions or concerns with the aforementioned items. Sincerely, URBAN SYSTEMS LTD. Mark Hall, AScT Civil Engineering Technologist Matt Smith, P.Eng. Project Engineer /mrh Enclosure cc: Linda Bie, P.Eng. IIES U:\Projects_KAM\0433\0008\01\2015-LS Grant Cost Estimate\ LET-regarding sanitary sewer updates.docx

4 Fifth Ave Lift Station Cost Cost Estimate Lift station LS 1 $ 250,000 $ 250,000 Valve Chamber LS 1 $ 25,000 $ 25,000 Site piping adjustments LS 1 $ 10,000 $ 10,000 Temporary over pumping LS 1 $ 42,000 $ 42,000 Groundwater remediation allowance LS 1 $ 50,000 $ 50,000 Roadway Restoration LS 1 $ 15,000 $ 15,000 Site Restoration Landscaping LS 1 $ 10,000 $ 10,000 Subtotal $ 402,000 Electrical service connection LS 1 $ 7,500 $ 7,500 Standby generator and installation LS 1 $ 45,000 $ 45,000 Kiosk with control panel and service LS 1 $ 70,000 $ 70,000 PLC and HMI Programming, update SCADA LS 1 $ 10,000 $ 10,000 Subtotal Electrical $ 132,500 Sub-Total $ 534,500 30% Contingency $ 160,350 15% Engineering $ 104,200 Total (Rounded) $ 799,000

5 Elm Street Lift Station Cost Cost Estimate Site restoration landscaping LS 1 $ 10,000 $ 10,000 Subtotal $ 10,000 Electrical service connection LS 1 $ 7,500 $ 7,500 Standby generator and installation LS 1 $ 37,500 $ 37,500 Kiosk with control panel and service LS 1 $ 70,000 $ 70,000 PLC and HMI Programming, update SCADA LS 1 $ 10,000 $ 10,000 Subtotal Electrical $ 125,000 Sub-Total $ 135,000 30% Contingency $ 40,500 15% Engineering $ 26,300 Total (Rounded) $ 202,000

6 17th Ave-Cedar Street Lift Station Cost Cost Estimate Internal piping adjustments LS 1 $ 20,000 $ 20,000 Temporary over pumping LS 1 $ 28,000 $ 28,000 Infiltration remediation (reline) LS 1 $ 40,000 $ 40,000 Site restoration landscaping LS 1 $ 10,000 $ 10,000 Subtotal $ 98,000 Electrical service connection LS 1 $ 7,500 $ 7,500 Standby generator and installation LS 1 $ 45,000 $ 45,000 Kiosk with control panel and service LS 1 $ 70,000 $ 70,000 PLC and HMI Programming, update SCA LS 1 $ 10,000 $ 10,000 Subtotal Electrical $ 132,500 Sub-Total $ 230,500 30% Contingency $ 69,150 15% Engineering $ 44,900 Total (Rounded) $ 345,000

7 Dogwood Lift Station Cost Cost Estimate Internal piping upgrades LS 1 $ 20,000 $ 20,000 Temporary over pumping LS 1 $ 14,000 $ 14,000 Site Restoration Landscaping LS 1 $ 10,000 $ 10,000 Subtotal $ 44,000 Electrical service connection LS 1 $ 7,500 $ 7,500 Standby generator and installation LS 1 $ 45,000 $ 45,000 Kiosk with control panel and service LS 1 $ 70,000 $ 70,000 PLC and HMI Programming, update SCA LS 1 $ 10,000 $ 10,000 Subtotal Electrical $ 132,500 Sub-Total $ 176,500 30% Contingency $ 52,950 15% Engineering $ 34,400 Total (Rounded) $ 264,000

8 Cranberry Place Lift Station Cost Cost Estimate Site restoration landscaping LS 1 $ 10,000 $ 10,000 Subtotal $ 10,000 Electrical service connection LS 1 $ 7,500 $ 7,500 Standby generator and installation LS 1 $ 45,000 $ 45,000 Service Kiosk with Transfer Switch LS 1 $ 45,000 $ 45,000 UPS Addition to Control System LS 1 $ 2,000 $ 2,000 Subtotal Electrical $ 99,500 Sub-Total $ 109,500 30% Contingency $ 32,850 15% Engineering $ 21,400 Total (Rounded) $ 164,000

9 Canoe View Lift Station Cost Cost Estimate Site restoration landscaping LS 1 $ 10,000 $ 10,000 Subtotal $ 10,000 Electrical service connection LS 1 $ 5,000 $ 5,000 Standby generator and installation LS 1 $ 37,500 $ 37,500 Service Kiosk with Transfer Switch LS 1 $ 45,000 $ 45,000 UPS Addition to Control System LS 1 $ 2,000 $ 2,000 Subtotal Electrical $ 89,500 Sub-Total $ 99,500 30% Contingency $ 29,850 15% Engineering $ 19,400 Total (Rounded) $ 149,000

10 Village Office Lift Station Cost Cost Estimate Site restoration landscaping LS 1 $ 10,000 $ 10,000 Subtotal $ 10,000 Electrical service connection LS 1 $ 5,000 $ 5,000 Standby generator and installation LS 1 $ 37,500 $ 37,500 Service Kiosk with Transfer Switch LS 1 $ 45,000 $ 45,000 UPS Addition to Control System LS 1 $ 2,000 $ 2,000 Subtotal Electrical $ 89,500 Sub-Total $ 99,500 30% Contingency $ 29,850 15% Engineering $ 19,400 Total (Rounded) $ 149,000

11 Summary of Sanitary Lift Station Upgrades Location of Upgrades Fifth Ave Lift Station Elm Street Lift Station 17th Ave Lift Station Dogwood Lift Station Cranberry Place Lift Station Canoeview Lift Station Village Office Lift Station Fifth Ave Lift Station Elm Street Lift Station 17th Ave Lift Station Dogwood Lift Station Cranberry Place Lift Station Canoeview Lift Station Village Office Lift Station Subtotal Subtotal Electrical Sub-Total 30% Contingency 15% Engineering Total (Rounded) Cost Estimate $ 402,000 $ 10,000 $ 98,000 $ 44,000 $ 10,000 $ 10,000 $ 10,000 $ 584,000 $ 132,500 $ 125,000 $ 132,500 $ 132,500 $ 99,500 $ 89,500 $ 89,500 $ 801,000 $ 1,385,000 $ 415,500 $ 270,100 $ 2,072,000

12 IIES Interior Instrument Engineering Services Ltd 1115 St. Paul Street Kelowna, BC V1Y 2C8 Phone: (250) Fax: (250) February 17, 2015 Valemount Lift Station Upgrades Preliminary Electrical and Control Information The Valemount lift stations can be broken into two groups, for the purposes of the electrical and controls upgrades: those that require a complete upgrade, and those that require a standby power upgrade. The stations that require a complete electrical and control upgrade are: 17 th Avenue 5 th Avenue Elm Street Dogwood The stations that require an upgrade to include standby power are: Cranberry Place Canoe View Office All sites are reported to have SCADA communications, so it has been assumed that the existing SCADA communication system can be used in the upgraded control panels. Information about existing electrical services and pump sizes was taken from the SCADA System Report, prepared by ICI in Complete Electrical Upgrade The proposed work included for the sites that require a complete electrical upgrade is as follows: Provide new kiosk with electrical service equipment and control panel Provide standby generator set The new kiosk will be two sided, plus an end compartment to isolate the wiring from the kiosk to the wet well. One side of the kiosk will house the electrical service equipment, including a main disconnect, automatic transfer switch to control the generator and transfer the loads, a surge protective device, and a transformer and distribution for heating and lighting loads. The other side of the kiosk will contain control items, including motor starters, the new PLC control panel, a UPS to operate the control system, and an intrinsic safety barrier junction box. Lift stations are corrosive environments, so it is recommended that the kiosk be of aluminum construction. The kiosk should also be insulated to help guard against freezing in the winter, and heating from the sun in summer. Baseboard heat and cooling fans are to be included in the kiosk. The PLC control panel is expected to match the control panel at the updated Ash Street lift station. The primary control system will use a level transmitter to provide start and stop controls to the pumps. The back up control system will use a high level float and timers, connected outside of the PLC and UPS, to operate the system in the event of a PLC or UPS failure. The float will be connected to the control panel through and intrinsic safety barrier, to ensure unsafe Voltages do not reach the wet well, Engineering-Installation-Maintenance

13 IIES Interior Instrument Engineering Services Ltd 1115 St. Paul Street Kelowna, BC V1Y 2C8 Phone: (250) Fax: (250) and meet the Canadian Electrical Code requirements. The new control panel will interface to the existing SCADA system, using the existing SCADA radio. The standby generator will be sized to operate all of the loads at the site, and will be installed in a separate weather-proof, sound-attenuated enclosure. In the event of a utility power failure, the automatic transfer switch will start the generator, and automatically transfer power to the generator once it is running. When utility power returns, the automatic transfer switch will transfer power back to the utility supply, and shut down the generator after a cool down period. It is expected that the generator will be diesel fuelled. The generator system will include a battery charger, and coolant heater to ensure it starts and requires a minimal warm up time. Standby Power Upgrade The proposed work for the sites identified as requiring a standby power upgrade includes: Provide a new electrical service kiosk Provide a standby generator set The existing electrical services have small distribution enclosures, which do not include enough space to install an automatic transfer switch (or in the case of the single phase services, service disconnect switch and automatic transfer switch ahead of the existing distribution loadcentre). The existing electrical service will be relocated to the new electrical service kiosk, which will have a main disconnect switch, transfer switch, and surge protective device. The existing distribution will be re-fed from the new service kiosk. The kiosk will be sized with enough space for the control equipment, to allow for the future relocation of the control panel and motor starters, but no allowance has been included to do that work in this estimate. The standby generator will function as described in the previous section. Engineering-Installation-Maintenance

Rolling Road (Route 638) Widening Project

Rolling Road (Route 638) Widening Project Rolling Road (Route 638) Widening Project From: 0.369 Mile North of Fairfax County Parkway (Route 286) To: Old Keene Mill Road (Route 644) State Project No. 0638-029-156, P104, R204, C504; UPC 5559 Public

More information

Pump Station 7 Improvements

Pump Station 7 Improvements Project Business Case ID: C04 2/18/2017 Pump Station 7 Project Purpose: The purpose of this project is to ensure that Pump Station 7 continues to operate in an efficient and effective manner following

More information

Rosedale Sanitary Sewer Feasibility Review Report

Rosedale Sanitary Sewer Feasibility Review Report Rosedale Sanitary Sewer Feasibility Review Report Submitted by: WEDLER ENGINEERING LLP 201 9300 Nowell Street Chilliwack BC V2P 4V7 Phone: 604 792 0651 Wedler File No: C13 5032/A December 6, 2013 STATEMENT

More information

City of Grand Forks Staff Report

City of Grand Forks Staff Report City of Grand Forks Staff Report Committee of the Whole December 1, 016 City Council December 19, 016 Agenda Item: Bids for City Project No. 7551 Lift Station No. 17 & 17A Rehabilitation Submitted by:

More information

Public Information Centre

Public Information Centre Junction Street Wastewater Pumping Station & Forcemain Schedule B Municipal Class Environmental Assessment Study Public Information Centre June 28, 2017. 6:00 to 8:00 pm. The Burlington Performing Arts

More information

XXXX. Knob Hill Wind Farm Project. Interconnection System Impact Study

XXXX. Knob Hill Wind Farm Project. Interconnection System Impact Study XXXX Knob Hill Wind Farm Project Report No. August 2010 British Columbia Hydro and Power Authority British Columbia Hydro and Power Authority 2010. All rights reserved.. DISCLAIMER OF WARRANTY, LIMITATION

More information

ANDERSON, ECKSTEIN AND WESTRICK, INC.

ANDERSON, ECKSTEIN AND WESTRICK, INC. ANDERSON, ECKSTEIN AND WESTRICK, INC. 51301 Schoenherr Civil Engineers Road, Shelby Township, Michigan 48315 Surveyors Architects 586-726-1234 Mr. Matthew Tepper City of Grosse Pointe Farms 90 Kerby Road

More information

The purpose of this report is to respond to the Notice of Motion CS-16-51, Generators for Fire Halls and Recreation Facilities, including:

The purpose of this report is to respond to the Notice of Motion CS-16-51, Generators for Fire Halls and Recreation Facilities, including: Public Report To: From: Report Number: Community Services Committee Ron Diskey, Commissioner, Community Services Department CS-17-18 Date of Report: March 24, 2017 Date of Meeting: March 30, 2017 Subject:

More information

Connect Series Accessories

Connect Series Accessories Connect Series Accessories 2015 Cummins Power Generation Inc. All rights reserved. Specifications are subject to change without notice. Cummins Power Generation and Cummins are registered trademarks of

More information

Possible Locations for EV Chargers

Possible Locations for EV Chargers Possible Locations for EV Chargers RECOMMENDATION: THAT Council approve the installation and locations for two electric vehicle (EV) Level 2 chargers at each of the following locations: Eustace Road near

More information

ACTION TRANSMITTAL No

ACTION TRANSMITTAL No Transportation Advisory Board of the Metropolitan Council of the Twin Cities DATE: January 4, 2016 TO: ACTION TRANSMITTAL No. 2016-19 TAC Funding and Programming Committee PREPARED BY: Joe Barbeau, Senior

More information

Connect Series Accessories

Connect Series Accessories Connect Series Accessories CONNECT SERIES ACCESSORIES Table of Contents ALTERNATOR HEATERS... 1 ANNUNCIATORS... 2 AUXILIARY... 3 AUXILIARY CONFIGURABLE SIGNAL INPUTS / RELAY OUTPUTS... 3 AUXILIARY OUTPUTS

More information

CHAIR AND MEMBERS CIVIC WORKS COMMITTEE MEETING ON FEBRUARY 6, 2018

CHAIR AND MEMBERS CIVIC WORKS COMMITTEE MEETING ON FEBRUARY 6, 2018 TO: FROM: SUBJECT: CHAIR AND MEMBERS CIVIC WORKS COMMITTEE MEETING ON FEBRUARY 6, 2018 KELLY SCHERR, P.ENG., MBA, FEC MANAGING DIRECTOR, ENVIRONMENTAL & ENGINEERING SERVICES AND CITY ENGINEER HAMILTON

More information

CITY of NOVI CITY COUNCIL

CITY of NOVI CITY COUNCIL CTY of NOV CTY COUNCL Agenda tem E March 23, 2015 cityofnovi.org SUBJECT: Approval of Change Order No. 1 to Great Lakes Power and Lighting for the 2014 Sanitary Lift Station project in the amount of $68,800

More information

ATTACHMENT - DFO STATEMENT OF NEED

ATTACHMENT - DFO STATEMENT OF NEED ATTACHMENT - DFO STATEMENT OF NEED Table of Contents Executive Summary... 3 1. Description of the Area... 5 1.1 Geographic Study Area... 5 1.2 Current System Configuration... 7 1.3 Distributed Generation...

More information

DES MOINES AIRPORT AUTHORITY BOARD SUMMARY OF REGULAR MEETING Des Moines International Airport Board Room May 13, 2014

DES MOINES AIRPORT AUTHORITY BOARD SUMMARY OF REGULAR MEETING Des Moines International Airport Board Room May 13, 2014 DES MOINES AIRPORT AUTHORITY BOARD SUMMARY OF REGULAR MEETING Des Moines International Airport Board Room May 13, 2014 Call to Order and Roll Call: Present: Erickson, Feldmann, Hansell, and Ward. Absent:

More information

Appendix C. Cost Estimates

Appendix C. Cost Estimates O Fallon Parks and Recreation Master Plan The cost estimates prepared for the ten year cost projections were estimated in 2010 US Dollars. The previous Implementation Strategies section of this Master

More information

Update on Community or Heritage Rail Project (Project Manager Services) The Engineering Department recommends that Council:

Update on Community or Heritage Rail Project (Project Manager Services) The Engineering Department recommends that Council: Corporate NO: R279 Report COUNCIL DATE: DECEMBER 18, 2006 REGULAR COUNCIL TO: Mayor & Council DATE: December 15, 2006 FROM: General Manager, Engineering FILE: 8710-20 (Heritage) SUBJECT: Update on Community

More information

CITY OF TORRANCE PUBLIC WORKS DEPARTMENT ENGINEERING DIVISION INFRASTRUCTURE UPDATE

CITY OF TORRANCE PUBLIC WORKS DEPARTMENT ENGINEERING DIVISION INFRASTRUCTURE UPDATE CITY OF TORRANCE PUBLIC WORKS DEPARTMENT ENGINEERING DIVISION INFRASTRUCTURE UPDATE TUESDAY, DECEMBER 5, 2017 1 DISCUSSION TOPICS Update of Infrastructure Action Plan (IAP) o Sidewalk and Roadway projects

More information

Alberta Electric System Operator Saleski Transmission Project Needs Identification Document

Alberta Electric System Operator Saleski Transmission Project Needs Identification Document Decision 2013-127 Alberta Electric System Operator Saleski Transmission Project Needs Identification Document ATCO Electric Ltd. Saleski 901S Substation and 144-kV Transmission Line 7L142 Facility Application

More information

WAYNE COUNTY CAPITAL PLAN SUMMARY

WAYNE COUNTY CAPITAL PLAN SUMMARY WAYNE COUNTY CAPITAL PLAN SUMMARY 2019-2023 7/10/2018 TOTAL PROJECT TOTAL NON-LOCAL TOTAL COUNTY COUNTY DEPARTMENT COSTS FUNDING COSTS Buildings and Grounds 7,065,000 0 7,065,000 Highway (Equipment) 395,000

More information

TOWN OF COBOURG 2017 OPERATING BUDGET ESTIMATES

TOWN OF COBOURG 2017 OPERATING BUDGET ESTIMATES ENVIRONMENTAL SUMMARY 2017 2017 2018 2019 FUNCTION 2016 2016 DEPT % FINAL % FORECAST FORECAST BUDGET YTD REQUEST APPROVED WPCP #1 1,546,378 1,319,457 1,581,945 2.3 1,581,945 2.3 1,615,151 1,671,755 WPCP

More information

Tahoe-Reno Industrial Center Total Bonding Amounts Engineer's Opinion of Probable Construction Costs (30% Submittal) Project No. 783.

Tahoe-Reno Industrial Center Total Bonding Amounts Engineer's Opinion of Probable Construction Costs (30% Submittal) Project No. 783. Total Bonding Amounts Brent Farr Date: 05/05/17 Item Project Estimated Cost 1 Induction Well 1 and Britain Ave Non potable Water Line $1,084,353 2 Storage Reservoir Upgrades $11,560,463 3 Booster Station

More information

Trailer Mounted Light Towers

Trailer Mounted Light Towers Trailer Mounted Light Towers Working late? Light up your job site with PowerTower Light Towers. Not just another light tower, our light towers are known for their versatility, durability, and simplicity.

More information

MPD Manifold 4-1/ psi with Integrated Control System

MPD Manifold 4-1/ psi with Integrated Control System MPD Manifold 4-1/16 5000 psi with Integrated Control System The MTC Managed Pressure Drilling (MPD) manifold has been designed to automatically maintain the annulus surface back pressure during drilling

More information

Appendix 11 RETURN TO APPENDICES LIST. High Voltage Power Supply Upgrade (Welcon Technologies Pty Ltd)

Appendix 11 RETURN TO APPENDICES LIST. High Voltage Power Supply Upgrade (Welcon Technologies Pty Ltd) Appendix 11 RETURN TO APPENDICES LIST High Voltage Power Supply Upgrade (Welcon Technologies Pty Ltd) GLADSTONE AREA WATERBOARD AWOONGA DAM HIGH VOLTAGE POWER SUPPLY UPGRADE Document: GJ543-RP-02B Submission

More information

MPD Manifold 4 x psi with Integrated Control System and Coriolis Flowmeter

MPD Manifold 4 x psi with Integrated Control System and Coriolis Flowmeter MPD Manifold 4 x 6 2000psi with Integrated Control System and Coriolis Flowmeter The MTC Managed Pressure Drilling (MPD) manifold has been designed to automatically maintain the annulus surface back pressure

More information

The cost estimation methodology used to update the charges and credits is the same methodology the Company utilized in the prior year s filing.

The cost estimation methodology used to update the charges and credits is the same methodology the Company utilized in the prior year s filing. LISA D. NORDSTROM Lead Counsel lnordstrom@idahopower.com December 28, 2018 Public Utility Commission of Oregon Filing Center 201 High Street SE, Suite 100 P.O. Box 1088 Salem, Oregon 97301 Re: Tariff Advice

More information

100 MW Wind Generation Project

100 MW Wind Generation Project A subsidiary of Pinnacle West Capital Corporation 100 MW Wind Generation Project CUSTOMER FINAL Feasibility Study Results By Transmission Planning, APS December 21, 2007 Executive Summary This Feasibility

More information

INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL

INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL INSTRUCTION MANUAL FILE: 091-106-150-XX-120 DATE: 10-2-2009 REV: A INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 MODEL # 091-106-150-XX-120 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC. 170

More information

UNIFIED GOVERNMENT Proposed Capital Maintenance Improvement Program (CMIP) Capital Cash Project Summary 5/14/18 Fund/Departm ent New Annual

UNIFIED GOVERNMENT Proposed Capital Maintenance Improvement Program (CMIP) Capital Cash Project Summary 5/14/18 Fund/Departm ent New Annual - 2023 Proposed Capital Maintenance Improvement Program (CMIP) Fund/Departm ent New Original Amended 2019 2020 2021 2022 2023 FY18-23 110 - City - General Fund Chief Knowledge Office 1 9 AUTO - 1997 -

More information

CTA Capital Construction Update May 17, 2007

CTA Capital Construction Update May 17, 2007 Block 37 Signals Project Brown Line Howard CTA Capital Construction Update May 17, 2007 1 Capital Construction Update Agenda Howard Station Reconstruction Brown Line Capacity Expansion Project Block 37

More information

April 17, 2018 CITY OF BONNEY LAKE WATER PROJECTS. Geoff Dillard, P.E.

April 17, 2018 CITY OF BONNEY LAKE WATER PROJECTS. Geoff Dillard, P.E. April 17, 2018 CITY OF BONNEY LAKE WATER PROJECTS Geoff Dillard, P.E. HOW TO DECIDE? Council vested in making informed decisions which protect the City s assets and citizens Factors that influence decisions

More information

PROCUREMENT SPECIFICATION DELTA MODEL DSC900 TRANSPORTABLE CRASH CERTIFIED RISING PLATE BARRIER SYSTEM

PROCUREMENT SPECIFICATION DELTA MODEL DSC900 TRANSPORTABLE CRASH CERTIFIED RISING PLATE BARRIER SYSTEM PROCUREMENT SPECIFICATION DELTA MODEL DSC900 TRANSPORTABLE CRASH CERTIFIED RISING PLATE BARRIER SYSTEM SYNOPSIS This Procurement Specification defines a CRASH CERTIFIED - TRANSPORTABLE BARRIER SYSTEM -

More information

GCG ASSOCIATES, INC. PROFESSIONAL CIVIL ENGINEERS AND LAND SURVEYORS 84 Main Street Wilmington, Massachusetts 01887

GCG ASSOCIATES, INC. PROFESSIONAL CIVIL ENGINEERS AND LAND SURVEYORS 84 Main Street Wilmington, Massachusetts 01887 GCG ASSOCIATES, INC. PROFESSIONAL CIVIL ENGINEERS AND LAND SURVEYORS 84 Main Street Wilmington, Massachusetts 01887 Phone: (978) 657-9714 Fax: (978) 657-7915 December 31,2.012 Mr. Charles Aspinwall Town

More information

Interconnection Feasibility Study Report GIP-222-FEAS-R3

Interconnection Feasibility Study Report GIP-222-FEAS-R3 Interconnection Feasibility Study Report GIP-222-FEAS-R3 System Interconnection Request #222 48 MW Steam Generating Facility Pictou County (53N) 2010 07 30 Control Centre Operations Nova Scotia Power Inc.

More information

Contract Awards for Tender Calls and for the Construction of Works Associated with the City's Basement Flooding Protection Program

Contract Awards for Tender Calls and for the Construction of Works Associated with the City's Basement Flooding Protection Program STAFF REPORT ACTION REQUIRED Contract Awards for Tender Calls 319-2013 and 70-2014 for the Construction of Works Associated with the City's Basement Flooding Protection Program Date: April 30, 2014 To:

More information

Capital Improvement Plan

Capital Improvement Plan PROGRAM DESCRIPTION: The represents City Council approved projects and includes each of the project's total costs and the estimated funding requirements for the next five years. Projects are funded by

More information

FIFE LAKE AREA UTILITY AUTHORITY BOARD OF COMMISSIONERS

FIFE LAKE AREA UTILITY AUTHORITY BOARD OF COMMISSIONERS FIFE LAKE AREA UTILITY AUTHORITY BOARD OF COMMISSIONERS DIRECTION OF SEWER SYSTEM #1 OPERATIONS & MAINTENANCE 2014 Fleis & VandenBrink Engineering Report - 11/25/14 U.S. Department of Agriculture Letter

More information

Technical Memorandum. To: From: Date: October 14 th, 2018 Project #: 1302 Project Name: Subject: Distribution:

Technical Memorandum. To: From: Date: October 14 th, 2018 Project #: 1302 Project Name: Subject: Distribution: Technical Memorandum To: Tom Hanrahan Jeff Sharp From: Date: October 14 th, 2018 Project #: 1302 Project Name: Subject: Distribution: Barrie Lockhart Road LP Conformity Review Scott Young Sorbara Group

More information

PHMSA Office of Pipeline Safety Dave Mulligan Western Region

PHMSA Office of Pipeline Safety Dave Mulligan Western Region PHMSA Office of Pipeline Safety Dave Mulligan Western Region Chevron Pipeline Releases Salt Lake City, Utah June 11, 2010 & December 1, 2011 Dave Mulligan U.S. Department of Transportation (US DOT) Pipeline

More information

AUTOMATIC STANDBY GENERATORS

AUTOMATIC STANDBY GENERATORS AUTOMATIC STANDBY GENERATORS Generac s standby generators provide the automatic backup power you need to protect your home and family during a power outage. Connected to your existing LP or natural gas

More information

Re: ENSC 305W/440W Project Proposal RAHS(Remote Automotive Heating System)

Re: ENSC 305W/440W Project Proposal RAHS(Remote Automotive Heating System) February 16, 2015 School of Engineering Science Simon Fraser University Burnaby, British Columbia V5A 1S6 Attn: Dr. Andrew Rawicz Re: ENSC 305W/440W Project Proposal RAHS(Remote Automotive Heating System)

More information

No Thoroughfare. Gated Private Road Ahead

No Thoroughfare. Gated Private Road Ahead No Thoroughfare Gated Private Road Ahead 1 Think: Safety and Security In our Community 2 Mainlands Secondary Entrance Barrier Gate Proposal Technology and Cost Study (as Prepared by Gate Committee on April

More information

XXXX. Kokish River Hydroelectric Project. Interconnection System Impact Study

XXXX. Kokish River Hydroelectric Project. Interconnection System Impact Study XXXX Kokish River Hydroelectric Project Report No. August 2010 British Columbia Hydro and Power Authority British Columbia Hydro and Power Authority 2010. All rights reserved.. DISCLAIMER OF WARRANTY,

More information

BC Hydro Case Study: Battery Energy Storage in Field, British Columbia, Canada. IEEE PES Meeting July 2014

BC Hydro Case Study: Battery Energy Storage in Field, British Columbia, Canada. IEEE PES Meeting July 2014 1 BC Hydro Case Study: Battery Energy Storage in Field, British Columbia, Canada IEEE PES Meeting July 2014 General BC Hydro Overview Crown Corporation Serving about 95% of province and 1.9 million customers

More information

Tulsa Transportation Management Area. Urbanized Area Surface Transportation Program

Tulsa Transportation Management Area. Urbanized Area Surface Transportation Program Tulsa Transportation Management Area Urbanized Area Surface Transportation Program FFY 2022 Application Information Sponsor Location Description STP Request Other Funds Broken Arrow Elm Place: Kenosha

More information

POWERING THE WAY Rental Power Planner. 877.YOUR.PWR ( ) holtcat.com. Your Business Powered Anywhere.

POWERING THE WAY Rental Power Planner. 877.YOUR.PWR ( ) holtcat.com. Your Business Powered Anywhere. POWERING THE WAY Rental Power Planner holtcat.com Your Business Powered Anywhere. PLANNING FOR TEMPORARY POWER: A Critical Management Duty As a facility manager, you know better than anyone that electrical

More information

MILLERSVILLE PARK TRAFFIC IMPACT ANALYSIS ANNE ARUNDEL COUNTY, MARYLAND

MILLERSVILLE PARK TRAFFIC IMPACT ANALYSIS ANNE ARUNDEL COUNTY, MARYLAND MILLERSVILLE PARK TRAFFIC IMPACT ANALYSIS ANNE ARUNDEL COUNTY, MARYLAND Prepared for: Department of Public Works Anne Arundel County Prepared by: URS Corporation 4 North Park Drive, Suite 3 Hunt Valley,

More information

Comprehensive Lift Station Evaluation Buffalo, Minnesota

Comprehensive Lift Station Evaluation Buffalo, Minnesota City of Buffalo Comprehensive Lift Station Evaluation Buffalo, Minnesota W3.088 Submitted by: Bolton & Menk, Inc. 040 Hwy East Willmar, MN 560 P: 30-3-3956 F: 30-3-970 Certification Comprehensive Lift

More information

Future Project Cost Adjustments

Future Project Cost Adjustments C H A P T E R 9 SCHEDULE OF IMPROVEMENTS The results of prioritizing the improvements assisted with establishing an implementation schedule that can be used by the City for preparing its 6-year CIP and

More information

MPD Manifold 4-1/ psi with Integrated Control System

MPD Manifold 4-1/ psi with Integrated Control System MPD Manifold 4-1/16 5000 psi with Integrated Control System The MTC Managed Pressure Drilling (MPD) manifold has been designed to automatically maintain the annulus surface back pressure during drilling

More information

21 Keep Residential Stairwells & Hallways Lit During Blackouts

21 Keep Residential Stairwells & Hallways Lit During Blackouts NEW CODE FURTHER ACTION 21 Keep Residential Stairwells & Hallways Lit During Blackouts I. Summary Issue: All buildings are required to have 90 minutes of emergency lighting so they can be safely evacuated.

More information

North Oregon Coast Area Study. Adam Lint

North Oregon Coast Area Study. Adam Lint North Oregon Coast Area Study Adam Lint PAGE 2 North Oregon Coast System Overview - Clatsop Study Covers: Transmission Switching Stations (Clatsop District): Astoria Lewis and Clark 115 kv Distribution

More information

Airpax Dimensions, Inc.

Airpax Dimensions, Inc. Airpax Dimensions, Inc. 4467 White Bear Parkway (651) 653-7000 St. Paul, MN 55110-7626 Fax (651) 653-7600 121177B OWNERS MANUAL JANUARY 2007 Airpax Dimensions, Inc. Uninterruptible Power System OWNERS

More information

Sub Regional RTEP Committee Mid-Atlantic

Sub Regional RTEP Committee Mid-Atlantic Sub Regional RTEP Committee Mid-Atlantic August 24, 2018 Proposal Window Exclusion Definitions The following definitions explain the basis for excluding flowgates and/or projects from the competitive planning

More information

Decision (Errata) Access Pipeline Inc. Errata to Decision Temporary Generation at Smoky Lake Pump Station.

Decision (Errata) Access Pipeline Inc. Errata to Decision Temporary Generation at Smoky Lake Pump Station. Decision 2011-424 (Errata) Access Pipeline Inc. Errata to Decision 2011-424 Temporary Generation at Smoky Lake Pump Station January 4, 2012 The Alberta Utilities Commission Decision 2011-424 (Errata):

More information

BC Hydro Undergrounding for 100 Avenue Widening Between King George Boulevard and 140 Street

BC Hydro Undergrounding for 100 Avenue Widening Between King George Boulevard and 140 Street CORPORATE REPORT NO: R191 COUNCIL DATE: September 17, 2018 REGULAR COUNCIL TO: Mayor & Council DATE: September 13, 2018 FROM: General Manager, Engineering FILE: 1717-054/H SUBJECT: BC Hydro Undergrounding

More information

Metcalf Avenue and Shawnee Mission Parkway Corridor

Metcalf Avenue and Shawnee Mission Parkway Corridor Metcalf Avenue and Shawnee Mission Parkway Corridor Improved transit service within the Metcalf and Shawnee Mission Parkway corridors is identified in the regional long range transportation plan and in

More information

Impacts of Hurricane Sandy to NYCDEP WWTPs and Pump Stations. December 12, 2012

Impacts of Hurricane Sandy to NYCDEP WWTPs and Pump Stations. December 12, 2012 Impacts of Hurricane Sandy to NYCDEP WWTPs and Pump Stations December 12, 2012 Presentation Agenda Overview of NYC Sewer System and Treatment Plants Preparations Made in Anticipation of Sandy Status of

More information

City of Grand Island Tuesday, October 10, 2017 Council Session

City of Grand Island Tuesday, October 10, 2017 Council Session City of Grand Island Tuesday, October 10, 2017 Council Session Item G-12 #2017-276 - Approving Change Order No. 1 for Lift Station No. 20 Upgrade and Force Main Rehabilitation & Lift Station No. 14 Abandonment;

More information

City of St. Pete Beach Model Capacity Report Addendum

City of St. Pete Beach Model Capacity Report Addendum Model Capacity Report - Addendum City of St. Pete Beach Model Capacity Report Addendum Prepared for: City of St. Pete Beach 155 Corey Avenue St. Pete Beach, FL 33706 Prepared By: Kimley-Horn and Associates,

More information

C Tenant Improvements 2,901, C Fire Standpipe Repairs and Fire Sprinkler System Upgrade for

C Tenant Improvements 2,901, C Fire Standpipe Repairs and Fire Sprinkler System Upgrade for GENERAL FUND (01) C017060.589000 EXPO Maintenance Yard Buffer Park 440,000 - - - C019098.589000 Downtown Santa Monica Temporary Use TOD Site 836,400 - - - M014078.589000 Swim Facilities Planned Maintenance

More information

CANADA LINE a Canadian P3 Success Story

CANADA LINE a Canadian P3 Success Story CANADA LINE a Canadian P3 Success Story Project Context The Canada Line An automated light rail rapid transit system linking downtown Vancouver with both Richmond and Vancouver International Airport Construction

More information

TEN YEAR PLANNING GUIDE SHASTA LAKE ELECTRIC UTILITY

TEN YEAR PLANNING GUIDE SHASTA LAKE ELECTRIC UTILITY TEN YEAR PLANNING GUIDE SHASTA LAKE ELECTRIC UTILITY 2011-2020 P+ PowerPlus Engineering A Department of STAR Energy Services, LLC TEN YEAR PLANNING GUIDE 2011-2020 SHASTA LAKE ELECTRIC UTILITY CITY OF

More information

Xebra Electrical Component Locations

Xebra Electrical Component Locations Xebra Electrical Component Locations Last updated on April 12, 2007 Copyright 2007. This document my not be reprinted, published, emailed or posted on the Internet without the approval of ZAP. Component

More information

Date: 04/20/2018 City Project No.: Addendum No.: 4. The following changes shall be made to the project plans and specifications:

Date: 04/20/2018 City Project No.: Addendum No.: 4. The following changes shall be made to the project plans and specifications: DEVELOPMENT SERVICES PHONE: (209) 668-5520 ENGINEERING DIVISION FAX: (209) 668-5563 156 S. BROADWAY, SUITE 150 TDD: (800) 735-2929 TURLOCK, CA 95380 engineering@turlock.ca.us Date: 04/20/2018 City Project

More information

Procedure 730: Collection System Operations and Maintenance

Procedure 730: Collection System Operations and Maintenance CITY OF GALT PUBLIC WORKS DEPARTMENT STANDARD OPERATING PROCEDURES Procedure 730: Collection System Operations and Maintenance Approval: Interim Director of Public Works Date CONTENTS A. Scope B. Objective

More information

BID FORM PART A. Total Quantity 1 LS $ - 2a Surveying, Layout, and Field Staking 1 LS $ - 2b Maintenance of Traffic 1 LS $ -

BID FORM PART A. Total Quantity 1 LS $ - 2a Surveying, Layout, and Field Staking 1 LS $ - 2b Maintenance of Traffic 1 LS $ - BID FORM PART A Name & Category Unit Unit Cost (B) Cost (AxB) GENERAL REQUIREMENTS 1 Mobilization (Maximum 3.0% of the total Contract Price) 1 LS $ - 2a Surveying, Layout, and Field Staking 1 LS $ - 2b

More information

Contract Awards December 22, Composite Report

Contract Awards December 22, Composite Report STAFF REPORT ACTION REQUIRED Contract Awards December 22, 2010 - Composite Report Date: December 16, 2010 To: From: Bid Committee Director, Purchasing and Materials Management Reference Various Calls SUMMARY

More information

How to fit the remote parking heater module

How to fit the remote parking heater module How to fit the remote parking heater module The function of this project is to convert a standard fuel burning heater on the diesel models of the Rover 75 and MG ZT to a remote controlled parking heater.

More information

APS150A SOUND ATTENUATED DUAL VOLTAGE/60HZ

APS150A SOUND ATTENUATED DUAL VOLTAGE/60HZ BARTONVILLE * CEDAR RAPIDS * DAVENPORT * EAST PEORIA * HANNIBAL * MOBERLY * ROCK FALLS * SPRINGFIELD * URBANA APS150A SOUND ATTENUATED DUAL VOLTAGE/60HZ FEATURES: EMISSIONS: EPA Tier 3 Certified at 60Hz

More information

Municipality of Strathroy- Caradoc

Municipality of Strathroy- Caradoc Directed to: Prepared by: Department: Subject: Municipality of Strathroy- Caradoc Mayor Vanderheyden and Members of Council Mark Harris Environmental Services Strathroy WPCP Blower Replacement Update Page

More information

VILLAGE OF ORLAND PARK

VILLAGE OF ORLAND PARK 14700 Ravinia Avenue Orland Park, IL 60462 www.orland-park.il.us Monday, 6:00 PM Village Hall Public Works Committee Chairman Michael F. Carroll Trustees James V. Dodge and Carole Griffin Ruzich Village

More information

Peninsula Corridor Electrification Project (PCEP)

Peninsula Corridor Electrification Project (PCEP) Peninsula Corridor Electrification Project (PCEP) Q2 Quarterly Update #13 October 1 December 31, 2017 JPB Board Meeting February 1, 2018 Agenda Item # 8b Electrification - Infrastructure Progression of

More information

FREQUENTLY ASKED QUESTIONS

FREQUENTLY ASKED QUESTIONS THE PROJECT Last updated on 2/19/16 FREQUENTLY ASKED QUESTIONS What s happening on Highway 169? The Minnesota Department of Transportation (MnDOT) is planning to rebuild and repair the infrastructure on

More information

REPORT TO THE CHIEF ADMINISTRATIVE OFFICER FROM THE DEVELOPMENT AND ENGINEERING SERVICES DEPARTMENT COMPRESSED NATURAL GAS TRANSIT FLEET UPDATE

REPORT TO THE CHIEF ADMINISTRATIVE OFFICER FROM THE DEVELOPMENT AND ENGINEERING SERVICES DEPARTMENT COMPRESSED NATURAL GAS TRANSIT FLEET UPDATE September 7, 2016 REPORT TO THE CHIEF ADMINISTRATIVE OFFICER FROM THE DEVELOPMENT AND ENGINEERING SERVICES DEPARTMENT ON COMPRESSED NATURAL GAS TRANSIT FLEET UPDATE PURPOSE To update Council on Kamloops

More information

Clay Township Regional Waste District CAPITAL & CONSTRUCTION COMMITTEE MEETING

Clay Township Regional Waste District CAPITAL & CONSTRUCTION COMMITTEE MEETING www.ctrwd.org Phone (317) 844-9200 Fax (317) 844-9203 CAPITAL & CONSTRUCTION COMMITTEE MEETING Monday, December 7, 2015 at 4:30 P.M. 10701 N. College Ave, Suite A, Indianapolis, IN 46280 AGENDA 1. Public

More information

CITY OF ELK GROVE CITY COUNCIL STAFF REPORT

CITY OF ELK GROVE CITY COUNCIL STAFF REPORT CITY OF ELK GROVE CITY COUNCIL STAFF REPORT AGENDA ITEM NO. 10.2 AGENDA TITLE: Receive Update on Citywide Light Emitting Diode (LED) Streetlight Conversion and Provide Guidance on Next Steps MEETING DATE:

More information

GES-202TLP Traffic Light System Installation Manual

GES-202TLP Traffic Light System Installation Manual GES-202TLP Traffic Light System Installation Manual M1603_TLP_Installation_Manual V1.0 2012-06-12 IMPORTANT EMERGENCY SHUTDOWN PROCEDURE ON THE INSIDE OF REAR COVER NOTE: The instructions contained in

More information

Columbus Collection and Treatment System Real Time Wet Weather Operational Implementation

Columbus Collection and Treatment System Real Time Wet Weather Operational Implementation Columbus Collection and Treatment System Real Time Wet Weather Operational Implementation Presenters Ed Heyob, CDM Smith Automation Engineer Kim Brown, JPWWTP Supervisor II Existing Collection System Rhodes

More information

UBC Watermain as shown on Sheet 202 : Sub total 97,050

UBC Watermain as shown on Sheet 202 : Sub total 97,050 Preliminary Cost Estimate Brock Commons Phase 1 Watermain replacement UBC Portion of Works only Replace existing 150mm dia CI and 200mm dia AC watermain with 200mm & 250mm dia DI (ductile iron) watermain

More information

FOUR-ON-THE SNOW Newsletter

FOUR-ON-THE SNOW Newsletter FOUR-ON-THE SNOW Newsletter A publication of Tucker Sno-Cat Corporation Made in the USA since 1942 NO SNOW TOO DEEP NO ROAD TOO STEEP December 2013 Volume 5 Issue 12 COLD FLUIDS Cold fluid can cause failures

More information

Public Works Department, Capital Improvement Program Project Tracking

Public Works Department, Capital Improvement Program Project Tracking Community Facilities Name CF-01 Eastshore State Park/Powell Street Bioswale Seeking grant funding. TT CF-02 South Bayfront Bridge and Horton Landing Park CF-03 / - 04 Transit Center Updated plans are being

More information

Electric Vehicle Charging Station Installation and Eco-Pass Updates. Report Prepared by: A. Rolston, Parking Operations Coordinator

Electric Vehicle Charging Station Installation and Eco-Pass Updates. Report Prepared by: A. Rolston, Parking Operations Coordinator Report to Council Date: File: 1862-01 To: From: Subject: City Manager D. Duncan, Manager, Parking Services Electric Vehicle Charging Station Installation and Eco-Pass Updates Report Prepared by: A. Rolston,

More information

White Paper Load Banks for Power System Testing

White Paper Load Banks for Power System Testing White Paper s for Power System Testing A load bank provides a consistent and repeatable electrical load that can be accurately controlled, measured and recorded. Load banks convert or dissipate the resultant

More information

Energy storage - two Canadian Case Studies ESA Annual Conference, Washington, June 4th. Alex Bettencourt Managing Director

Energy storage - two Canadian Case Studies ESA Annual Conference, Washington, June 4th. Alex Bettencourt Managing Director Energy storage - two Canadian Case Studies ESA Annual Conference, Washington, June 4th Alex Bettencourt Managing Director National Association Made Up of Entire Industry Utilities Industry Academia / R&D

More information

CITY OF BELLEVILLE 2017 Capital Budget

CITY OF BELLEVILLE 2017 Capital Budget CITY OF BELLEVILLE 2017 Capital Budget Proposed Financing COMBINED SERVICES 1.001 Bridge St W Coleman to Highland Design EDS 73 300.0 150.0 150.0 1.002 University Ave McFarland Dr to Tice Cres EDS 65 1,900.0

More information

Dunvegan Hydroelectric Project. For Glacier Power Limited. Preliminary Interconnection Study

Dunvegan Hydroelectric Project. For Glacier Power Limited. Preliminary Interconnection Study ` Dunvegan Hydroelectric Project For Glacier Power Limited Preliminary Interconnection Study Prepared by Pung Toy, P. Eng. and Ata Rehman, P. Eng. September 24, 2004 Table of Contents Table of Contents...

More information

APD-ULJ250. Standby Power

APD-ULJ250. Standby Power AKSA Generation has been producing industrial generator sets with an innovative compact design and excellence in quality for over 30 years. AKSA has been providing reliable power through three main production

More information

PID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation

PID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation PID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation Prepared by: Entergy Services, Inc. T & D Planning L-ENT-17A 639 Loyola Avenue New Orleans, LA 70113 Rev Issue Date

More information

Questions Section: Do you have questions that aren't covered? Please contact us!

Questions Section: Do you have questions that aren't covered? Please contact us! Questions Section: 1. What are the screw terminals on the back of my XP600 for? 2. How do I hook up a remote turn-on switch for my XP250 / XP600 / XP1100/ MX series inverter? 3. Can I sell power back to

More information

TECHNICAL MEMORANDUM

TECHNICAL MEMORANDUM TECHNICAL MEMORANDUM Summary Description of Requirements and Guidelines for: Heavy Maintenance Facility (HMF), Terminal Layup/Storage & Maintenance Facilities & Right-of-Way Maintenance Facilities TM 5.3

More information

Transporter. Current Flow Diagram No. 7 / 1. Edition Glow plug relay (104) 14 - Diesel control unit (137) 15 - Diesel control unit (137)

Transporter. Current Flow Diagram No. 7 / 1. Edition Glow plug relay (104) 14 - Diesel control unit (137) 15 - Diesel control unit (137) Page 1 of 7 Current Flow Diagram No. 7 / 1 Edition 07.2002 1.9 ltr./50 kw Cat diesel, engine codes ABL From August 1998 For alternatives to relay and fuse positions as well as multi-pin connector wiring

More information

FREQUENTLY ASKED QUESTIONS

FREQUENTLY ASKED QUESTIONS THE PROJECT Last updated on 9/8/16 FREQUENTLY ASKED QUESTIONS What s happening on Highway 169? The Minnesota Department of Transportation (MnDOT) is planning to rebuild and repair the infrastructure on

More information

Requirements for Secondary Voltage Revenue Metering (750 V and less)

Requirements for Secondary Voltage Revenue Metering (750 V and less) Requirements for Secondary Voltage Revenue Metering (750 V and less) To view the latest revision of this document go to: http://www.bchydro.com/ext/metering/ January 28, 2010 Copyright 2008 by BC Hydro.

More information

Welcome. Liberty Utilities Reliability Reporting Workshop. October 3 & 6, 2017

Welcome. Liberty Utilities Reliability Reporting Workshop. October 3 & 6, 2017 Welcome Liberty Utilities Reliability Reporting Workshop October 3 & 6, 2017 1 Agenda Purpose of Workshops System Overview Key Utility Initiatives Reliability Performance Plans for Reliability Improvements

More information

Interconnection Feasibility Study Report GIP-023-FEAS-R1. Generator Interconnection Request # MW Wind Generating Facility Inverness (L6549), NS

Interconnection Feasibility Study Report GIP-023-FEAS-R1. Generator Interconnection Request # MW Wind Generating Facility Inverness (L6549), NS Interconnection Feasibility Study Report GIP-023-FEAS-R1 Generator Interconnection Request # 23 100 MW Wind Generating Facility Inverness (L6549), NS February 16, 2006 Control Centre Operations Nova Scotia

More information

City Hall 539 Phoenix Street South Haven, Michigan Telephone (269) Fax (269)

City Hall 539 Phoenix Street South Haven, Michigan Telephone (269) Fax (269) City of South Haven City Hall 539 Phoenix Street South Haven, Michigan 49090-1499 Telephone (269) 637-0700 Fax (269) 637-5319 Dunkley and Black River Infrastructure Improvements Dunkley - Dyckman Avenue

More information

DIESEL FIRED COOLANT HEATERS

DIESEL FIRED COOLANT HEATERS DIESEL FIRED COOLANT HEATERS Coolant heaters work independently of the engine and thus offer a double plus: pre-heating the vehicle s passenger compartment and the engine. The heaters are integrated in

More information