LED Emergency Lighting

Size: px
Start display at page:

Download "LED Emergency Lighting"

Transcription

1 TrustSight Emergency SEV & High Voltage Datasheet TrustSight ED Emergency ighting TrustSight inear SEV & High Voltage The application of ED technology within the lighting sector also requires integration of reliable emergency lighting equipment inside luminaires. The range of TrustSight Emergency ighting solutions offers easy designin and is compatible with all dimmable and nondimmable linear high voltage and SEV ED drivers. The TrustSight emergency driver is designed for Maintained solutions but can also be used in a nonmaintained Emergency ighting configuration. It offers Selftesting (IEC 62034) and is available with 3 hours Emergency duration. Two battery technologies are supported by the TrustSight: imh batteries and ithiumion batteries. The TrustSight ED emergency drivers come with battery harness and ED indicator. The TrustSight driver can also be used as an independent emergency driver with the separately available strain relief accessories. Benefits Features Application Compliant with international standards. Easy system integration with ED driver and ED modules Builtin and Independent use Constant output power Compatible with imh and iion batteries Automatic cell count detection Doubleinsulated/SEV output Insulation Class I and II luminaires Offices, supermarkets, department stores, schools, etc. December 2018

2 ogistical data Product name 12C Pieces per box TrustSight Basic 1555ViMH TrustSight Basic 45300ViMH TrustSight PRO 1555ViMH TrustSight PRO 45300ViMH TrustSight DAI 1555ViMH TrustSight DAI 45300ViMH TrustSight Basic 1555V FP TrustSight Basic 45300V FP TrustSight PRO 1555V FP TrustSight PRO 45300V FP TrustSight DAI 1555V FP TrustSight DAI 45300V FP The TrustSight PRO and DAI types are equipped with selftest functionality according IEC The TrustSight Basic can only be tested manually (via mains interruption or with a test switch). EDindicator and battery connection cable are included in the driver box. Product name 12C Pieces per box TrustSight 3.6V 3cell 4000mAh battery imh TrustSight 4.8V 4cell 4000mAh battery imh TrustSight 6.0V 5cell 4000mAh battery imh TrustSight 3.2V 3cell 4500mAh battery FP TrustSight 6.4V 4cell 3000mAh battery FP TrustSight 9.6V 6cell 3000mAh battery FP The selected TrustSight battery pack will determine the output power in Emergency mode. Product name 12C Pieces per box TrustSight Strain relief TrustSight battery independent box TrustSight Indicator ED TrustSight battery harness imh TrustSight battery harness FP EM system contains of: TrustSight driver for builtin application

3 Wiring & Connections Electrical input data Rated input voltage range Vac Rated input frequency range Hz Rated input current 35 Vac, 2S3P FP pack Rated input voltage 230 Vac Rated input power 6 Vac, 2S3P FP pack Rated input power with battery charger idle < 1 W Power Factor 0.7 Battery charge state Input voltage AC Vac Performance range Input voltage AC Vac Safety operational range Input frequency AC Hz Performance range Input frequency AC Hz Safety operational range Switched mains contact current 2.4 A Maximum permissible current, Basic only Electrical output data Regulation method Constant Power Full output voltage range Output voltage SEV Vdc Output voltage max. SEV 60 Vpk UOUT Output voltage HV Vdc Output voltage max. 330 Vpk UOUT Output power W Depending on selected battery pack IED max 1 A Maximum ED current from AC driver Switch over time ac. Emergency Mode < 500 ms Battery pack v.s. output power Specification item 12C description Max Output power in EM mode TrustSight 3.6V 3cell 4000mAh battery imh imh 3cell, 4000mAh 3W (2.7W) TrustSight 4.8V 4cell 4000mAh battery imh imh 4cell, 4000mAh 4W (3.7W) TrustSight 6.0V 5cell 4000mAh battery imh imh 5cell, 4000mAh 5W (4.7W) TrustSight 3.2V 3cell 4500mAh battery FP FP 1S3P, 4500mAh 2W (2.1W) TrustSight 6.4V 4cell 3000mAh battery FP FP 2S2P, 3000mAh 3W (2.9W) TrustSight 9.6V 6cell 3000mAh battery FP FP 3S2P, 3000mAh 5W (4.7W) * Batteries are sufficient charged within 24 hours after being discharged. DAI The TrustSight drivers with DAI functionality comply with DAI standard IEC IEC62386 and IEC (particular requirement for control gear Selfcontained emergency lighting). Commands supported are given below: Inhibit Query lamp failure Rest Re_light_reset_inhibit Start function test Start duration test Stop test Reset function test done flag Reset duration test done flag Reset lamp time Store test execution timeout Store prolong time Start identification Query battery charge Query test timing Query duration test result Query lamp emergency time Query lamp total operation time Query emergency level Query rated duration Query emergency mode Query features Query Failure status Query Emergency status

4 Wiring & Connections The TrustSight drivers with DAI functionality support SimpleSet configuration. Several setting can be selected to configure the TrustSight driver. Parameter Default setting Range description Output power % Output power can be tuned as % of selected power Region Selection Europe Europe Australia Duration test acceptance time minutes Australia: 90 minutes SelfTest Mode fixed Fixed/DAI Fixed mode gives standard FT/DT interval times Function Test (FT) interval 28 days Fixed mode Duration Test (DT) interval 24 weeks Fixed mode Function Test (FT) interval 7 days DAI mode, Configurable via DAI Duration Test (DT) interval 52 weeks DAI mode, Configurable via DAI Battery Type imh, FP Product dependent Depends on the selected TrustSight type Battery capacity Auto Detect, Auto Detect The TrustSight detects the cell count automatically imh 3cell for 3W imh 4cell for 4W imh 5cell for 5W FP (1S3P) for 2W FP (2S2P) for 3W FP (3S2P) for 5W In the diagnostics tab of MultiOne the next parameters can be read out: Parameter Unit amp emergency time Hours amp total operation time Hours ast duration test time Minutes Time since last duration test Days Total number of discharge cycles umber of complete battery discharges Reset battery detection: It is possible to set back the battery capacity (cell count) to auto detect, e.g. when the system is wrongly configurated. To reset the battery cell count there are two options: Direct changing the battery cellcount in the memory bank via DAI, e.g. in the final tester. Power cycle scheme to Reset to factory defaults: 1. Apply Mains power, Apply 12Vdc on battery input (at same time or within 2s) 2. After 1s the Indicator ED starts fast flashing RED for 2s (4 times) 3. Remove 12V while flashing. 4. After 1s the Indicator ED becomes steady GREE for 2s. 5. remove Mains power. To change to Australia mode: 1. Apply Mains power, Apply 12Vdc on battery input (at same time or within 2s) 2. After 1s the Indicator ED starts fast flashing RED for 2s (4 times) 3. Remove 12V while flashing, Press testbutton, Indicator ED becomes dark. 4. After 4s remove Mains power In ergo, pressing the testbutton during the procedure will reset the device with Australia mode enabled, and not pressing the button will reset the device with Australia mode disabled. ot removing the 12V within the 3s or applying for at least 1.5s will not perform the factory reset. ote that applying an invalid battery voltage will trigger battery failure state (RED indicator ED), which when mains is lost, will not produce emergency light. To verify the successful execution, do connect a valid battery and mains. If it takes 30 seconds before the indicator ED starts flashing, the reset was successful. Remove power well before the 30 seconds to be sure the product stays in autodetect mode. To verify that Australia mode is active, press testbutton for at least 10s while battery is charging. The 30s functional test is started. When test succeeds, the ED indicator is flashing fast green (for 5 days). This is specific for Australia mode.

5 Wiring & Connections Builtin use: mains input wire crosssection Independent use: mains input wire crosssection Input wire strip length mm Independent use: input/output thick/thin cable diameter / mm Output wire crosssection Input wire strip length mm mm2 AWG mm2 AWG mm2 AWG WAGO250, solid and stranded wire WAGO250, solid and stranded wire WAGO250, solid and stranded wire WAGO250, solid and stranded wire WAGO250, solid and stranded wire WAGO250, solid and stranded wire Maximum cable length 0.6 m Total length of wiring including ED module, one way DA DA G TrustSight DAI (ED Emergency Driver Gen3) ED ED G TrustSight PRO (ED Emergency Driver Gen3) ED ED SW SW G TrustSight BASIC (ED Emergency Driver Gen3) ED ED Insulation TrustSight Pro & DAI driver Mains Battery ED in/output Status ED DAI Mains A Battery Double A ED in/output HV: Double, V: SEV Functional A Status ED Double o Functional A DAI Basic Supplementary Supplementary Supplementary A Insulation TrustSight Basic driver Mains Battery ED in/output Status ED SW line Mains A Battery Double A ED in/output HV: Double, V: SEV functional A Status ED Double o functional A SW line Basic Supplementary Supplementary Supplementary A

6 Connection examples Connection example with TrustSight HV with HV ED modules Switched line eutral ine inear ED_driver Out Out Battery Unswitched ine Unswitched eutral DAI DAI DA DA G TrustSight DAI (ED Emergency Driver Gen3) ED ED Indicator ED Switched line eutral ine inear ED_driver Out Out Battery Unswitched ine Unswitched eutral Indicator ED G TrustSight PRO (ED Emergency Driver Gen3) ED ED eutral eutral ine inear ED_driver Out Out Battery Switched line Unswitched ine Unswitched eutral SW SW G TrustSight BASIC (ED Emergency Driver Gen3) ED ED Indicator ED

7 Connection examples Connection example with TrustSight SEV with V ED modules Switched line eutral ine SEV ED_driver Out Out Battery Unswitched ine Unswitched eutral DAI DAI DA DA G TrustSight DAI (ED Emergency Driver Gen3) ED ED 33V Indicator ED Switched line eutral ine SEV ED_driver Out Out Battery Unswitched ine Unswitched eutral Indicator ED G TrustSight PRO (ED Emergency Driver Gen3) ED ED 33V eutral eutral ine SEV ED_driver Out Out Battery Switched line Unswitched ine Unswitched eutral Indicator ED SW SW G TrustSight BASIC (ED Emergency Driver Gen3) ED ED 33V Warning: The TrustSight V SEV driver does not support operation combined with nonsev AC drivers.

8 Dimensions and weight Specification item builtin version value Unit Condition ength 205 mm Width 30 mm Height 21 mm Fixing hole diameter 4.1 mm Fixing hole distance mm Weight 85 gram Specification item independent version value Unit Condition ength 238 mm Width 30 mm Height 21 mm Fixing hole diameter 4.1 mm Fixing hole distance mm Weight 100 gram

9 Battery dimensions imh battery 3.6V 3cell 4000mAh battery imh Max height = 21mm 4.8V 4cell 4000mAh battery imh Max height = 21mm 65mm between packparts 6.0V 5cell 4000mAh battery imh Max height = 21mm 65mm between packparts Parts ist Item Quantity Description Mounting PCB 1, 2, 2 Cell 3, 4, 5 HRH T Battery/PCB insulation wrap PVC Connector 1 Molex 55572P wire 2 U1007, 20AWG Warning: The battery wires currently do not support independent operation with respect to compliance per IEC clause unless a fire and heat resistant sleeve is put around the wires (not included). For independent use with a nonsev AC driver the battery wires and ED indicator wires must have a supplementary insulation sleeve.

10 Battery dimensions FP battery 3.2V 3cell 4500mAh battery FP Max height = 21mm 6.4V 4cell 3000mAh battery FP Max height = 21mm 65mm between packparts 9.6V 6cell 3000mAh battery FP Max height = 21mm 65mm between packparts Parts ist Item Quantity Description Mounting PCB 1, 2, 2 223X16 Cell 3, 4, 6 FR18650E1500 Battery/PCB insulation wrap PVC, white Connector 1 Molex R2 wire 2 U1007, 20AWG Warning: The battery wires currently do not support independent operation with respect to compliance per IEC clause unless a fire and heat resistant sleeve is put around the wires (not included). For independent use with a nonsev AC driver the battery wires and ED indicator wires must have a supplementary insulation sleeve.

11 Battery dimensions Battery box Ambient temperature driver C Ambient temperature imh battery pack 0 50 C Ambient temperature FP battery pack 0 55 C Tcasemax driver 75 C lifetime 70 khrs Tcasemax imh battery pack 55 C during charging Tcasemax imh battery pack 50 C ifetime 4 years in operation Tcasemax FP battery pack 55 C during charging Tcasemax FP battery pack 55 C ifetime 6 year in operation Maximum housing temperature driver 110 C In case of failure Relative humidity driver % oncondensing Storage temperature and humidity Storage Ambient temperature driver C Storage Ambient temperature imh battery pack C For 6 months Storage Ambient temperature FP battery pack C For 12 months Relative humidity driver 5 95 % oncondensing ifetime Driver lifetime 70,000 hours Measured temperature at Tcpoint is Tcase max. imh battery 4 year Maximum failures = 10% imh battery warranty 1 year As long as the cell is treated in accordance with the specification and / or Handling precautions and Prohibitions. FP battery 6 year FP battery warranty 3 Year As long as the cell is treated in accordance with the specification and / or Handling precautions and Prohibitions. TrustSight features / protections Specification item value Remark Condition Open load protection ED Yes Short circuit protection ED Yes Hot wiring ED o Suitable for luminaire Insulation Class I and II Acc. IEC Open load protection battery connection Yes Automatic recovering Short circuit protection battery connection Yes Automatic recovering Reverse polarity protection battery connection Yes Automatic recovering

12 Battery dimensions Certificates and standards Specification item value Remark Approval marks CE /EEC/ET Kitemark pending Ingress Protection classification (IP) 20 Compliances and approvals IEC IEC E (Fmark) acc. IEC ed 8.0 IEC61347 E 55015/CISPR15 IEC / E IEC / E IEC E E (650 C/850 C) AS (A1) AS (A2) AS IEC IEC Excluding high risk task areas Inrush current Ipeak 5 A Input voltage 230 V Mains current pulse time half peak 110 µs Input voltage 230 V, measured at 50% Ipeak Max. number of drivers A B type B MCB Touch current Typical touch current (parasitical) < 0.7 mapk To all accessible parts, ED module contribution not included Surge immunity Mains surge immunity (diff. mode) 1 kv, acc. IEC , 2 Ohm 1.2/50µs Mains surge immunity (comm. mode) 2 kv / other, acc. IEC , 12 Ohm 1.2/50µs

13 Disclaimer 2017 Philips ighting Holding B.V. All rights reserved. This document contains information relating to the Philips ighting portfolio, intended for companies who may be interested in developing their product offering. ote that the information provided is subject to change. Philips ighting does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract Revision date: December 3, 2018

TrustSight LED Emergency Lighting

TrustSight LED Emergency Lighting TrustSight Emergency ar 20-95V 3W/6W Datasheet TrustSight LED Emergency Lighting TrustSight ar 20-95V 3W/6W The application of LED technology within the lighting sector also requires integration of reliable

More information

TrustSight LED Emergency Lighting

TrustSight LED Emergency Lighting TrustSight Emergency Point 15-55 V 3 W Datasheet TrustSight LED Emergency Lighting TrustSight Point 15-55 V 3 W The application of LED technology within the lighting sector also requires integration of

More information

Long lifetime and robust protection against moisture, vibration and temperature. Configurable operating windows (AOC)

Long lifetime and robust protection against moisture, vibration and temperature. Configurable operating windows (AOC) Xitanium LED driver Datasheet Xitanium FULL Prog LED Xtreme drivers Xitanium FULL Prog LED Xtreme drivers Philips Xitanium Full Prograable LED drivers are specifically designed to deliver the highest performance,

More information

Long lifetime and robust protection against moisture, vibration and temperature. Configurable operating windows (AOC)

Long lifetime and robust protection against moisture, vibration and temperature. Configurable operating windows (AOC) Xitanium LED driver Datasheet Xitanium FULL Prog LED Xtreme drivers Xitanium FULL Prog LED Xtreme drivers Philips Xitanium Full Prograable LED drivers are specifically designed to deliver the highest performance,

More information

TrustSight. Emergency driver. Design-in Guide. TrustSight. LED Emergency driver

TrustSight. Emergency driver. Design-in Guide. TrustSight. LED Emergency driver TrustSight Emergency driver Designin Guide TrustSight ED Emergency driver May 2018 Contents Introduction to this guide 3 Applications 3 Information and support 3 Designin support 3 Determine which documents

More information

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series EM converter EM converter PRO 200 V PRO series Product description lighting Driver with DAI interface and automatic test function For self-contained emergency lighting For modules with a forward voltage

More information

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series PRO 50 V PRO series Product description lighting Driver with DAI interface and automatic test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output

More information

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series ST 50 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power SEFTEST 1 2 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with self-test function For self-contained emergency lighting SEV for output voltage

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power PRO EZ-3, 1 2 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with I interface and automatic test function For self-contained emergency lighting

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power PRO EZ-3, 1 2 W Emergency lighting units Product description emergency lighting supply unit with I interface and automatic test function Properties Mains and emergency operation I interface

More information

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series ST 90 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC

More information

Safety, compliance and peace of mind

Safety, compliance and peace of mind TrustSight LED emergency systems Safety, compliance and peace of mind TrustSight LED emergency drivers They ll never see it until they need it TrustSight LED emergency systems what s new? Without reliable

More information

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series EM converter EM converter BASIC 200 V BASIC series Product description lighting Driver for manual testing For modules with a forward voltage of 50 200 V ow profile casing (21 x 30 mm cross-section) For

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power SEFTEST 1 2 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with self-test function For self-contained emergency lighting SEV for output voltage

More information

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series BASIC 50 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow profile

More information

Emergency lighting units EM Inverter

Emergency lighting units EM Inverter T, 0 0 V 0/0 Hz BASIC version Product description Emergency lighting supply unit for manual testing For T fluorescent lamps ow-profile casing ( x 0 mm cross-section) -year guarantee Properties or h rated

More information

CertaDrive 60W 24VDC 220/240V

CertaDrive 60W 24VDC 220/240V ertarive LE drivers atasheet ertarive 60W 24V 220/240V The constant voltage driver for LE applications High frequency, compact size and long lifetime. The constant voltage LE drivers, operation with 24V

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power BASIC 1 2 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing For self-contained emergency lighting SEV for output voltage < 60

More information

Emergency lighting units EM series. EM PRO EZ-3, V PRO version

Emergency lighting units EM series. EM PRO EZ-3, V PRO version T T TC-DE TC-SE TC-TE TC-F TC- TC-DD Tc EM, 0 40 V PRO version Product description Emergency lighting supply unit with DAI interface and automatic test function For linear and compact fluorescent lamps

More information

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series BASIC 90 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC ow profile

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled EM converter EM converter BASIC icd 50 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 10 54 V SEV for

More information

Emergency lighting units EM powerled. EM powerled BASIC 4W Emergency lighting LED Driver

Emergency lighting units EM powerled. EM powerled BASIC 4W Emergency lighting LED Driver BASIC 4W Emergency lighting Driver Product description Emergency lighting Driver for manual testing For self-contained emergency lighting SEV for output voltage < 60 V DC ow profile casing (21 x 30 mm

More information

Emergency lighting units EM INVERTER

Emergency lighting units EM INVERTER T T8 TC- TC-F DE TC- TC-SE TC-TE TC-DD Tc EM, 0 40 V 0/0 Hz PRO version Product description Emergency lighting supply unit with DAI interface and automatic test function For linear and compact fluorescent

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled EM converter EM converter BASIC icd/imh 250 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 50 250 V ow

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled M BASIC 1 W Emergency lighting Driver 1 W Product description Emergency lighting Driver for manual testing For self-contained emergency lighting on maintained operation SEV for output voltage < 60 V DC

More information

Emergency lighting units EM powerled. EM powerled BASIC CLE Emergency lighting LED Driver

Emergency lighting units EM powerled. EM powerled BASIC CLE Emergency lighting LED Driver BASIC CE Emergency lighting ED Driver Product description ED Driver for mains operation with integrated Simple CORRIDOR FUCTIO (CF) and emergency lighting function for manual testing For selfcontained

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled M BASIC 1 W Emergency lighting Driver 1 W Product description Emergency lighting Driver for manual testing For self-contained emergency lighting on maintained operation SEV for output voltage < 60 V DC

More information

Experience bright and vivid colors

Experience bright and vivid colors Fortimo LED Fortimo SLM C 930 PC 1205 L13 2024 G7 Datasheet Experience bright and vivid colors Fortimo LED SLM PC 1205 L13 2024 G7 Fortimo LED SLM Gen7 continues to focus on the combination of Quality

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled EM converter EM converter BASIC MH/iFePO4 250 V BASIC series Product description Self contained emergency lighting Driver for manual testing For modules with a forward voltage of 50 250 V ow profile casing

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled BASIC MH/iFePO4 90 V BASIC series Product description Self contained emergency lighting Driver for manual testing For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC ow profile

More information

Experience bright and vivid colors

Experience bright and vivid colors Fortimo LED Fortimo SLM 120 L09 1619 G7 Datasheet Experience bright and vivid colors Fortimo LED SLM 120 L09 1619 G7 Fortimo LED SLM Gen7 continues to focus on the combination of Quality of Light and performance.

More information

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version T5 T8 TC- TC-F DE TC- TC-SE TC-TE TC-DD T5c EM SEFTE, 220 240 V SEFTEST version Product description Emergency lighting supply unit with self-test function For linear and compact fluorescent lamps ow-profile

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled PRO EZ-3, 4 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with LI interface and automatic test function For self-contained emergency lighting SELV for output

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled BASIC MH/iFePO4 250 V BASIC series Product description Self contained emergency lighting Driver for manual testing For modules with a forward voltage of 50 250 V ow profile casing (21 x 30 mm cross-section)

More information

Experience bright and vivid colors

Experience bright and vivid colors Fortimo LED Fortimo SLM PW 120 L09 1619 G7 Datasheet Experience bright and vivid colors Fortimo LED SLM PW 120 L9 1619 G7 Fortimo LED SLM Gen7 continues to focus on the combination of Quality of Light

More information

Emergency lighting units EM series

Emergency lighting units EM series EM power PRO EZ-3 Emergency lighting supply units Product description emergency lighting supply unit with DALI interface and automatic test function Properties Mains and emergency operation DALI interface

More information

Emergency lighting units EM powerled. EM powerled BASIC CLE Emergency lighting LED Driver

Emergency lighting units EM powerled. EM powerled BASIC CLE Emergency lighting LED Driver BASIC CE lighting ED Driver roduct description ED Driver for mains operation with integrated Simple CRRIDR FUCTI () and emergency lighting function for manual testing For luminaire installation For the

More information

Emergency lighting units EM series. EM BASIC lp-2, V BASIC version. Technical data. Ordering data. Article number

Emergency lighting units EM series. EM BASIC lp-2, V BASIC version. Technical data. Ordering data. Article number Product description Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps ow-profile casing ( x 0 mm cross-section) Properties or h rated duration Compatible with all

More information

Emergency Lighting Control Gear

Emergency Lighting Control Gear Emergency 3W 6W Dual Wattage Emergency Driver Emergency ighting Control Gear SelfTest Version HEM06T / HEM07T Applications Emergency conversion units to provide constant power output in emergency mode.

More information

Emergency lighting units EM LED Light Engines

Emergency lighting units EM LED Light Engines EM readyapply SELFTEST W EM readyapply Product description LED emergency module suitable for direct installation in ceilings Complete set with integrated electronics, LED module, heat sink, optics and

More information

Input Current at 240V (A) Max. Input Power (W) Enclosure

Input Current at 240V (A) Max. Input Power (W) Enclosure Output Power (W) Output Voltage (V) Output Current (A) Efficiency@ Max Load Tcase Max Input Current at 240V (A) Max. Input Power (W) Inrush Current (Apk/50%- µs) Max. THD (%) Power Factor @ Max Load Surge

More information

Emergency lighting units EM series. EM BASIC, V BASIC version

Emergency lighting units EM series. EM BASIC, V BASIC version T T TCDE TCSE TCTE TC TCDD EM, 0 0 V version roduct description Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps Small dimensions ( x mm crosssection) roperties

More information

Emergency lighting units PC COMBO

Emergency lighting units PC COMBO TC-DD PC CFL E COMBO, 230 240 V 50/60 Hz Compact fluorescent lamps Product description Combination of electronic ballast and emergency lighting unit For TC-DD compact fluorescent lamps For manual testing

More information

High-density LED modules that sell

High-density LED modules that sell Fortimo LED Fortimo SLM C 930 PC 1204 L09 1619 G7 Datasheet High-density LED modules that sell Fortimo LED SLM PC 1204 L09 1619 G7 For retailers it is essential to create an atmosphere that keeps customers

More information

Experience good performance with affordable cost

Experience good performance with affordable cost CertaFlux LED CertaFlux LED SLM 1201 L06 G1 Datasheet Experience good performance with affordable cost CertaFlux LED SLM G1 Certaflux LED SLM is a new CoB family from Philips. This range provides a more

More information

Experience bright and vivid colors

Experience bright and vivid colors Fortimo LED Fortimo SLM C 930 PC 1203 L09 1619 G7 Datasheet Experience bright and vivid colors Fortimo LED SLM PC 1203 L09 1619 G7 Fortimo LED SLM Gen7 continues to focus on the combination of Quality

More information

Emergency lighting units EM powerled. EM powerled BASIC 15 W CLE Emergency lighting LED Driver

Emergency lighting units EM powerled. EM powerled BASIC 15 W CLE Emergency lighting LED Driver E BASIC 15 W CE lighting ED Driver roduct description ED Driver for mains operation with integrated Simple CRRIDR FUCTI () and emergency lighting function for manual testing For luminaire installation

More information

Emergency lighting units PC COMBO

Emergency lighting units PC COMBO T5 PC, 220 240 V 50/60 Hz Linear fluorescent lamps Product description Combination of electronic ballast and emergency lighting unit For T5 fluorescent lamps Low-profile casing (21 x 30 mm cross-section)

More information

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter Features TRIAC Dimmable LED Driver Triac dimmable with leading or trailing edge dimmers Class II with SELV output (no earth required) Extra-large screw terminals and integrated cable clamps for easy installation

More information

Table of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4

Table of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4 Data sheet Integrated emergency converter for fluorescent lamps zone 2 Ex 100,000 h suitable for zone 2 hazardous areas For mains and battery supply Integrated battery management inear V inear V Emergency

More information

Emergency lighting units EM powerled. EM powerled BASIC 15 W CLE Emergency lighting units LED

Emergency lighting units EM powerled. EM powerled BASIC 15 W CLE Emergency lighting units LED powered powered BASIC 15 W CE lighting units ED roduct description Controlgear for ED for mains operation with integrated simple CRRIDR FUCTI () and emergency lighting funtion for manual testing For luminaire

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled PRO DIM C 45 W Combined emergency lighting LED Driver Product description Dimmable built-in LED Driver Emergency lighting LED Driver with DALI interface and automatic test function For self-contained emergency

More information

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal) 86 Timer modules 86 Timer modules for use in conjunction with relay & socket. 86.00T - Multi-function & multi-voltage timer module 86.30T - Bi-function & multi-voltage timer module Complies with EN 45545-2:2013

More information

Safety and peace of mind

Safety and peace of mind TrustSight LED Emergency drivers Safety and peace of mind TrustSight LED Emergency drivers They ll never see it until they need it TrustSight LED Emergency systems what s new? Without emergency lighting

More information

Key features and benefits

Key features and benefits CertaFlux LED CertaFlux LCM400 Gen3 Datasheet CertaFlux LED system Key features and benefits Excellent Total Cost of Ownership with attractive payback times irtually maintenance-free due to long life-time:

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled BASIC FX SR 50 W Combined emergency lighting LED Driver Product description Independent fixed output LED Driver for mains operation with integrated Simple CORRIDOR FUNCTION (CF) Emergency lighting function

More information

Input Current at 240V (A) Max. Input Power (W) Dimming Method 1-10V Isolated. Enclosure

Input Current at 240V (A) Max. Input Power (W) Dimming Method 1-10V Isolated. Enclosure Power (W) Voltage (V) (A) Efficiency @ Max Load Tcase max Input at 240V (A) Max. Input Power (W) Inrush (Apk/50%- µs) Max. THD (%) Power Factor @ Max Load Surge Protection Common/Di ff (KV) Weight (Lbs)

More information

EM BASIC V 50/60 Hz

EM BASIC V 50/60 Hz T, T, TCDD, TC, TCE, TCDE, TCTE linear and compact lamps 00 V 0/0 Hz RoH 0 00 Description: Emergency lighting modules with hour or hour duration. Five pole technology = pole changeover and a delayed action

More information

Experience bright and vivid colors

Experience bright and vivid colors Fortimo LED Fortimo LED SLM 1216 L2 28 G6 Datasheet Experience bright and vivid colors Fortimo LED SLM 1216 L2 28 G6 Fortimo LED SLM Gen6 continues to focus on the combination of Quality of Light and performance.

More information

Experience bright and vivid colors

Experience bright and vivid colors Fortimo LED Fortimo LED SLM 1 L09 1619 G6 Datasheet Experience bright and vivid colors Fortimo LED SLM 1 L09 1619 G6 Fortimo LED SLM Gen6 continues to focus on the combination of Quality of Light and performance.

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled ST FX SR 45 W Combined emergency lighting LED Driver Product description Independent dimmable LED Driver Emergency lighting LED Driver with automatic selftest functionality For self-contained emergency

More information

DALI 650mA LED Driver

DALI 650mA LED Driver Installation Guide DGLC650C18DD PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU Diginet Control Systems Pty Ltd ABN 89 095

More information

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL) LINEAR LED DRIVERS ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL) 186443, 186444, 186486, 186487, 186488, 186491, 186492, 186737 Typical Applications Built-in in linear luminaires for Office lighting

More information

ELEMENT. Product family datasheet. Constant Voltage Non dimmable

ELEMENT. Product family datasheet. Constant Voltage Non dimmable ELEMENT Constant Voltage Non dimmable Areas of application _ Suitable for luminaires of protection class II _ Decorative lighting in hospitality, restaurants and Shops _ Shelf lighting for shops _ Cove

More information

Experience bright and vivid colors

Experience bright and vivid colors Fortimo LED Fortimo LED SLM 1211 L19 28 G6 Datasheet Experience bright and vivid colors Fortimo LED SLM 1211 L19 28 G6 Fortimo LED SLM Gen6 continues to focus on the combination of Quality of Light and

More information

Experience bright and vivid colors

Experience bright and vivid colors Fortimo LED Fortimo LED SLM 15 L1 24 G6 Datasheet Experience bright and vivid colors Fortimo LED SLM 15 L1 24 G6 Fortimo LED SLM Gen6 continues to focus on the combination of Quality of Light and performance.

More information

Max. Input Power (W) Input Current. Inrush 347V Vin 60/ C. 480V Vac Vin 85 / 115. Dimming Method.

Max. Input Power (W) Input Current. Inrush 347V Vin 60/ C. 480V Vac Vin 85 / 115. Dimming Method. Power (W) Voltage (V) Current (A) Efficiency@ Max Load Max Case Temp. ( C) Input Current Max. Input Power (W) Inrush Current (Apk/50%-µs) THD @ Max Load (%) Power Factor @ Max Load Surge Protection Common/Diff

More information

Fortimo LED Line Gen3

Fortimo LED Line Gen3 LED Line 1 ft 650 lm 3R HV3 Datasheet Fortimo LED Line Gen3 Fortimo LED Line systems are designed to produce pure white light for general lighting applications with high efficiency levels. The Fortimo

More information

Experience bright and vivid colors

Experience bright and vivid colors Fortimo LED Fortimo LED SLM CW 1205 L13 2024 G6 Datasheet Experience bright and vivid colors Fortimo LED SLM CW 1205 L13 1619 G6 Fortimo LED SLM Gen6 continues to focus on the combination of Quality of

More information

Max. Input Power (W) Input Current. Inrush. 277 Vin 7.4 / 600. Dimming Method. 1-10V Isolated. Enclosure

Max. Input Power (W) Input Current. Inrush. 277 Vin 7.4 / 600. Dimming Method. 1-10V Isolated. Enclosure Output Power (W) Output Voltage (V) Output Current (A) Efficiency@ Max Load Max Case Temp. ( C) Input Current Max. Input Power (W) Inrush Current (Apk/50%-µs) THD @ Max Load (%) Power Factor @ Max Load

More information

LED Driver EM converterled ST Product Manual. ø4,5 175,5

LED Driver EM converterled ST Product Manual. ø4,5 175,5 LED Driver EM converterled ST Product Manual 34 209 183 209 183 34 33 82 34 ø4,5 175,5 34 175 175,5 34 175 ø4,5 34 41 82 ø4,5 209 183 41 82 34 209 183 34 175 ø4,5 82 33 17 Table of Contents Scope of documentation

More information

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT Product description One-LED Solo TM is a non-maintained, self-contained LED emergency luminaire comprising an Omni-LED emergency LED driver, hinged rechargable battery and a flush-mount SELV lamp head.

More information

Experience bright and vivid colors

Experience bright and vivid colors Fortimo LED Fortimo LED SLM Food 1211 L19 2828 G6 Datasheet Experience bright and vivid colors Fortimo LED SLM Food 1211 L19 2828 G 6 Fortimo LED SLM Gen6 continues to focus on the combination of Quality

More information

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets 86 Series - Timer modules Features 86.00 86.30 Timer modules for use in conjunction with relay & socket. 86.00 - Multi-function & multi-voltage timer module 86.30 - Bi-function & multi-voltage timer module

More information

650mA Phase Dimmable LED Driver

650mA Phase Dimmable LED Driver Installation Guide DGLC650C18PD PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU Diginet Control Systems Pty Ltd ABN 89 095

More information

Experience bright and vivid colors

Experience bright and vivid colors Fortimo LED Fortimo LED SLM PW 18 L15 24 G6 Datasheet Experience bright and vivid colors Fortimo LED SLM PW 18 L15 24 G6 Fortimo LED SLM Gen6 continues to focus on the combination of Quality of Light and

More information

DALI Emergency LED Driver - 350/700/1000mA Constant Current

DALI Emergency LED Driver - 350/700/1000mA Constant Current User and Installation Guide DGLCEM035CD-AU DGLCEM070CD-AU DGLCEM100CD-AU - 350/700/1000mA Constant Current PATENT PENDING/REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation

More information

Experience bright and vivid colors

Experience bright and vivid colors Fortimo LED Fortimo LED SLM PW 1205 L13 2024 G6 Datasheet Experience bright and vivid colors Fortimo LED SLM PW 1205 L13 2024 G6 Fortimo LED SLM Gen6 continues to focus on the combination of Quality of

More information

Max. Input Power (W) Input Current V Isolated DALI

Max. Input Power (W) Input Current V Isolated DALI Output Power (W) Output Voltage (V) Output Current (A) Efficiency@ Max Load Max Case Temp. ( C) Input Current Max. Input Power (W) Inrush Current (A pk /5%- µs) THD @ Max Load (%) Power Factor @ Max Load

More information

1000mA - 650mA Phase Dimmable LED Driver

1000mA - 650mA Phase Dimmable LED Driver Installation Guide DGLC1000C25PD 1000mA - 650mA Phase Dimmable LED Driver PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU

More information

Flexible system approach

Flexible system approach FastFlex LED board 2x8/757 DS Gen3 Datasheet Flexible system approach Outstanding performance while enabling OEM optical differentiation in road, urban and industrial lighting applications. Benefits Enables

More information

Max. Input Power (W) Input Current v 2 2 0v 2 40v. Enclosure

Max. Input Power (W) Input Current v 2 2 0v 2 40v. Enclosure Output Power (W) Output Voltage (V) Output Current (A) Efficiency@ Max Load Max Case Temp. ( C) Input Current Max. Input Power (W) Inrush Current (Apk/50%-µs) THD @ Max Load (%) Power Factor @ Max Load

More information

EMERGENCY ONE-LED TM OMNI-LED DST TM LED DALI EMERGENCY CONVERSION MODULE WITH SELF-TEST

EMERGENCY ONE-LED TM OMNI-LED DST TM LED DALI EMERGENCY CONVERSION MODULE WITH SELF-TEST Product description Omni-LED DST TM is a range of DALI Self-Test emergency lighting conversion modules housed in a compact low-profile enclosure, and suitable for use with maintained, self-contained LED

More information

Max Load. Max. Load. 100W 3-50VDC mA > 90% < 20% > 0.95 RFID P/N: XXXXXXXXXX CERTIFIED TO CSA STD. C22.2 NO.

Max Load. Max. Load. 100W 3-50VDC mA > 90% < 20% > 0.95 RFID P/N: XXXXXXXXXX CERTIFIED TO CSA STD. C22.2 NO. WIDTH DRIVEN HEIGHT MAGNITUDE LIGHTING AFLEX LINEAR DIMMABLE E465183 DIM DOWN TO 0.1% CLASS P CLASS 2 QUICK SPECS The AFlex Series of Constant Current Programmable LED Drivers offers high efficiency, smooth

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled BASIC FX 80 W Combined emergency lighting LED Driver Product description Fixed-output LED Driver for mains operation with integrated Simple CORRIDOR FUNCTION (CF) Emergency lighting LED Driver with manual

More information

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply EM readyapply BASIC W EM readyapply Product description LED emergency module suitable for direct installation in ceilings Complete set with integrated electronics, LED module, heat sink, optics and battery

More information

DC/DC converters - MINI-PS DC/ 5-15DC/

DC/DC converters - MINI-PS DC/ 5-15DC/ Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid

More information

Emergency lighting units EM INVERTER

Emergency lighting units EM INVERTER T5 T8 TC-DEL TC-SEL TC-TEL TC-L TC-DD EM, 230 240 V 50/60 Hz version Product description Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps Small dimensions (28

More information

OPTOTRONIC LED Power Supply OTi 30W Emergency Driver Technical Specifications

OPTOTRONIC LED Power Supply OTi 30W Emergency Driver Technical Specifications www.osram.us/optotronic OPTOTRONIC LED Power Supply OTi 30W Emergency Driver Technical Specifications Electrical Specifications Input General Information Item Number 57403 & 57404 Type Constant Current,

More information

Three-Phase Soft Starters

Three-Phase Soft Starters Submittal Data English Language/IP Units 04/14 Contact Information: Hyper Engineering, Pty. Ltd. 4 / 14 Ralph Black Dr Wollongong Nth, NSW 2500 AUSTRALIA www.hypereng.com sales@hypereng.com (+61) 2 4229

More information

Experience bright and vivid colors

Experience bright and vivid colors Fortimo LED SLM holders Gen1 Datasheet Experience bright and vivid colors Fortimo SLM H G1 Fortimo LED SLM Gen5 continues to focus on the combination of Quality of Light and performance. By offering the

More information

HID-PV m PGJ5 20/P CDM LPF

HID-PV m PGJ5 20/P CDM LPF - 1 - Philips Lighting Electronics GDC Eindhoven Author: Johan Kokx April 2011 DESIGN IN SHEET Contents 1. Introduction 3 2. Version management 3 3. Ordering 3 4. Dimensions and mechanical design-in 4

More information

OPTOTRONIC LED Power Supply OTi 50W Emergency Driver - Technical Specifications

OPTOTRONIC LED Power Supply OTi 50W Emergency Driver - Technical Specifications www.osram.us/optotronic OPTOTRONIC LED Power Supply OTi 50W Emergency Driver - Technical Specifications GENERAL INFORMATION Item Number 57405 & 57406 ELECTRICAL SPECIFICATIONS Input Input Voltage (VAC)

More information

Xitanium. LED drivers. Reliable, high performance technology for extreme LED applications. For today, for tomorrow

Xitanium. LED drivers. Reliable, high performance technology for extreme LED applications. For today, for tomorrow Xitanium LED drivers Reliable, high performance technology for extreme LED applications For today, for tomorrow Xitanium LED Xtreme drivers are ideal for demanding environments Outdoor Philips LED Xtreme

More information

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control

More information

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC Characteristics time delay relay 2 functions - 0.02 s..300 h - 24..240 V AC - 2 OC Complementary Product front plate size Control type Housing material Main Range of product Product or component type Electrical

More information

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A) A Complete solution for small battery-backed dc instrument power systems. DATASHEET Supply 12Vdc 8A or 24Vdc 6A loads Ideal for RTU s, dataloggers, remote field instrumentation, alarm systems, etc. where

More information

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD Soft starting of 3-phase scroll compressors up to 95Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user

More information

Model Number Structure

Model Number Structure Solid State Relays (Single-phase) G3PB New Single-phase Solid State Relays with Compact Size for Heater Control Slim models with a thickness of only 22.5 mm are also available. Compact design achieved

More information