REOWAVE passive The new generation of harmonic filters. NEW Overcurrent indication signal Temperature monitoring Potential-free signal contact

Size: px
Start display at page:

Download "REOWAVE passive The new generation of harmonic filters. NEW Overcurrent indication signal Temperature monitoring Potential-free signal contact"

Transcription

1 REOWAVE passive The new generation of harmonic filters NEW Overcurrent indication signal Temperature monitoring Potential-free signal contact

2 REOWAVE passive The new generation of harmonic filters Fulfill with REOWAVEpassive the following standards: Electrical components are continually becoming smaller, more efficient and cheaper. To achieve this, most applications include components such as thyristors or frequency converters. The components are also known as non-linear loads because their characteristic curve is not a straight line, which leads to many u ndesirable problems. In particular, these include harmonics. Harmonics are an example of the type of problem that are often simply not recognised correctly, but can cause significant malfunctioning particularly with the increasing use of non-linear loads. Harmonics cause, for example, interference phenomena such as: Creating additional losses resulting in unnecessary consumption of energy Reduced lifetime of transformers due to destruction of the insulation Resonances in the supply networks Measurement errors Errors in tripping fuses Serious faults in IT systems. The solution for these problems is the REOWAVE passive! This device is used at the place where the problems arise where the biggest effect can be achieved. REOWAVE passive is based on proven components of the REO CNW family such as REO mains filters and REO harmonic filters which, thanks to their excellent characteristics and the special circuit design of REOWAVE passive, efficiently keep the harmonics away from the mains network. Mains Netz Nichtlineare Non-linear load Mains Last Netz Nichtlineare Non-linear load Last REO WAVE Diagram 1: Uncontrolled rectifier Diagram 2: Diode rectifier with REOWAVE passive Diagram 3: Current (blue) und voltage (red) for a B6 rectifier configuration with scaled values Diagram 4: Current (blue) und voltage (red) for a B6 rectifier with REOWAVE passive; scaled values

3 REOWAVE passive Save money with less reactive power In the course of rising energy costs and growing CO 2 emissions minimizing losses in the transmission grid gains more and more importance. An important factor are the reactive currents. These currents do not contribute to the effective power, but stress all components in the current path and cause additional losses to the ohmic resistance component of the lead. Reactive currents are, for example, harmonics caused by the usage of frequency. However, reducing the energy efficiency is not only a burden on the environment because more energy is consumed for a steady performance - at the same time the costs increase for the operator of the installations, as they have to pay the reactive power. Mains chokes, DC chokes or Harmonicfilter of REO filter unwanted harmonics and help to counteract the resulting reactive current. Thus, the reactive power is diminished, the energy requirement and the running costs are reduced. Measurements at a frequency converter of 22 kw to the motor shaft Non unfiltered filtro Induttanza 1% Ukmains 1%Uk di linea Induttanza 2% Ukmains 2%Uk di linea Induttanza 4% Ukmains 4%Uk di linea REOWAVE passive choke choke choke l input [A] 42,4 41,6 37,7 3,8 32,0 Q [kvar] 19,6 18,0 1,2 10,2 2, Current and power factor at a REOWAVEpassive CNW 8981 / A / 400V / 0Hz Our favorite: REOWAVEpassive - save up to 30% energy

4 REOWAVE passive Automatically monitor filter performance more security for your systems d Loa % Load 0 8 % d n Loa 00 e 1 e % Gr low 10 > Yel d e R NEW Overcurrent indication signal Temperature monitoring Potential-free signal contact In additon to providing excellent harmonic filtering performance, the REOWAVEpassive can also besupplied with these additional options: Overcurrent indication signals Temperature monitoring Floating signalling contacts Automatic disconnection of the filter in the event of a system problem Monitoring and shutdown - temperature and filter circuit supervision The options allow optimisation of the mains network quality and overall system security and allow better monitoring by a PLC or supervisory system. Further details of the additional features: Onsite measurement of power failures FLUKE, ELSPEK Overcurrent indication signal The REOWAVEpassive includes compact measurement and monitoring electronics, which constantly measure the current and indicates status accordingly GREEN = power consumption approx 80% (based on the rated current of the filter) YELLOW = power consumption approx 100% (based on the rated current of the filter) Customized Power Quality solutions RED = power consumption above 10% (based on the rated current of the filter) The status is signalled via a potential-free signal contact and may initiate further action.

5 REOWAVE passive PE L1 L2 L3 Mains Mains choke Load PE L1 L2 L3 Display Current Absorption circuit 10% Red 100% Yellow 80% Green Logic module Signals Fan Overtemperature Overcurrent 230 V Fan Principle of operation REOWAVE passive The REOWAVE passive filters harmonics, and ensures: Temperature monitoring Bespoke electronics monitor the operating temperature of the inductive components, used within the filter. If these exceed the safe operating temperature, a potential-free contact will indicate this. Disconnection of the filter function in case of failure If an overtemperature condition is discovered the mains is automatically disconnected after a pre-determined delay in order to avoid permenant system damage. All error messages are reset when the power is again returned to the rated operating condition. Optionally with corresponding plugs and sockets for immediate use without large installations, - like that, immediate beginning of the savings! Reduction of the THDI value Increasing network stability Reduction of current consumption Calculate your savings Reduction of equipment costs Simple integration into existing systems Increase of operational safety

6 The REOWAVE passive Plus Reactive power optimization - reduce additional costs -REOWAVEpassive Plus - Reduce power consumption by approx. 20% Specially developed control circuitry in the REOWAVEpassive Plus ensures optimum performance, not only is the unit protected in the case of Overtemperature and Overload but it can also be safely used in the start-up mode of a Variable Speed Drive, by bypassing the internal shunt element of the circuit. This minimize the absorbed reactive power and protects the internal REOWAVE filter capacitors. The absorbed reactive power is reduced over the entire range by 30%. In order to optimize the reactive power, the filter circuit is only switched on from a certain current, preventing a reactive current component through the filter choke Traffic function - Monitoring and indication of the rated current Potential-free outputs for temperature / overcurrent Protection and deactivation of filter function for overheating and reactive power optimization

7 REOWAVE passive REOWAVE passive harmonic filter with a potential for savings REOWAVE passive doesn t only give protection against harmonics significant reduction of costs is also possible. The way that REOWAVE passive works results in reductions in current and current harmonics, enabling significantly smaller fuses, cabling and transformers to be used. REOWAVE passive therefore enables not only energy cost savings but also savings in equipment costs. Measurement on a converter without REOWAVE passive Measurement on a converter with REOWAVE passive Current 2,7 A I 67 % I7 43 % THDI 81% Current 19,7 A I 2,7 % I7 1,8 % THDI 4,4 l [A] 22,00 20,00 18,00 Converter without REOWAVE passive Converter with REOWAVE passive Limit value by EN ,00 14,00 12,00 12,00 10,00 10,00 8,00 8,00 6,00 6,00 4,00 2,00 4,00 2,00 0,00 0, Harmonics

8 REOWAVE passive Image 1: The design allows for the parallel connection of two REOWAVEpassive to increase the power capacity. Mains Netz REO WAVE Non-linear Nichtlineare load Last REO WAVE Mains Netz REO WAVE Non-linear Nichtlineare loadlast Image 2: Naturally several nonlinear loads can be suppressed with a single REOWAVEpassive. The filter must merely be suitably rated for the required power. REOWAVE passive approved REO quality REOWAVEpassive is a filter unit which consists out of approved REO CNW components. This filter unit includes a REO mains filter and a REO harmonics filter. The mains filters function is the pre-supression of the mains as well as the shielding against external harmonics. It filters the harmonics caused by the B6 circuit (thyristor, diode bridge etc.), effects a preliminary suppression of network interference, screens the application from extraneous harmonics and enables a cost-saving in equipment selection and energy consumption. Mains Netz Non-linear Nichtlineare loadlast REO WAVE REO Mains Netzfilter REO Oberwellen- Harmonics filter Umrichter/ Prüfling Manufactured by UL-guidelines!

9 REOWAVE passive in IP 00 Image 1 - u D=7mm Image 2 - v D=7mm Image 3- w D=7mm CAPACITORS

10 REOWAVE passive 400 V / 0 Hz Electrical and mechanical data Insulation class: F Climate class: 2/08/21 DIN IEC 68 Teil 1 Ambient temperature: 40 C Protection: IP 00 The components are delivered as separate components for customer mounting Typ CNW/ Image Nr. Choke1/ Choke2 Rated current [A] Losses [W] L B/ B2 Chokes 1 Chokes 2 Capacitors H N1 N2 L B H N1 N2 L B H N1 N2 N3 N4 Weight [kg] 8981/6 8981/ / / / /4 8981/ 8981/ / / / / / / / / /0 8981/ , , , , , , , , , , , / Due to the special conception a special design is required - please contact us!

11 REOWAVE passive 480 V / 0 Hz Electrical and mechanical data Insulation class: F Climate class: 2/08/21 DIN IEC 68 Teil 1 Ambient temperature: 40 C Protection: IP 00 The components are delivered as separate components for customer mounting Typ CNW/ Image Nr. Choke1/ Choke2 Rated current [A] Losses [W] L B/ B2 Chokes 1 Chokes 2 Capacitors H N1 N2 L B H N1 N2 L B H N1 N2 N3 N4 Weight [kg] 8981/ / / / /4 8981/ 8981/ / / / / / / / / /0 8981/ / , , , , , , , , , , , / Due to the special conception a special design is required - please contact us!

12 REOWAVE passive 690 V / 0 Hz Electrical and mechanical data Insulation class: F Climate class: 2/08/21 DIN IEC 68 Teil 1 Ambient temperature: 40 C Protection: IP 00 The components are delivered as separate components for customer mounting Typ CNW/ Image Nr. Choke1/ Choke2 Rated current [A] Losses [W] L B/ B2 Chokes 1 Chokes 2 Capacitors H N1 N2 L B H N1 N2 L B H N1 N2 N3 N4 Weight [kg] 8981/6 8981/ / / / /4 8981/ 8981/ / / / / / / / / /0 8981/ / Due to the special conception a special design is required - please contact us!

13 REOWAVE passive in IP 20 Image 1 Image 2 Image 3 Image 4 Image Image 6

14 Electrical and mechanical data Insulation class: F Climate class: 2/08/21 DIN IEC 68 Teil 1 Ambient temperature: 40 C Protection: IP 20 Different housings, depending on the power REOWAVE passive 400 V / 0 Hz Type Image Nr. Rated current [A] Losses [W] Housing dimensions in mm L B H/H1 H2 N1 N2 N3 D Weight [kg] Terminals [mm²] CNW 8981/6 1 CNW 8981/9 1 CNW CNW CNW 8981/22 2 CNW 8981/32 2 CNW 8981/36 2 CNW 8981/4 3 CNW 8981/ 3 CNW 8981/70 3 CNW 8981/90 4 CNW CNW CNW CNW 8981/200 CNW 8981/230 CNW 8981/270 CNW 8981/330 CNW 8981/370 CNW 8981/400 CNW 8981/40 CNW 8981/0 CNW 8981/60 CNW 8981/800 6 CNW CNW The REOWAVE passive is used in the following markets: Drives technology Renewable energies Railway technologies

15 REOWAVE passive 480 V / 60 Hz Electrical and mechanical data Insulation class: F Climate class: 2/08/21 DIN IEC 68 Teil 1 Ambient temperature: 40 C Protection: IP 20 Different housings, depending on the power Type Image Nr. Rated current [A] Losses [W] Housing dimensions in mm L B H/H1 H2 N1 N2 D Weight [kg] Terminals [mm²] CNW 8981/9 1 CNW CNW CNW 8981/22 2 CNW 8981/32 2 CNW 8981/36 2 CNW 8981/4 3 CNW 8981/ 3 CNW 8981/70 3 CNW 8981/90 4 CNW CNW CNW CNW 8981/200 CNW 8981/230 CNW 8981/270 CNW 8981/330 CNW 8981/370 CNW 8981/400 CNW 8981/40 CNW 8981/0 CNW 8981/60 CNW 8981/800 6 CNW CNW

16 REO AG Brühler Straße 100 D-4267 Solingen Tel.: +49 (0) Fax: +49 (0) info@reo.de Internet: Version_ _EN_1 Divisions: REO Vibratory Feeding and Power Electronics Division Brühler Straße 100 D-4267 Solingen Tel.: +49 (0) Fax: +49 (0) info@reo.de REO Train Technologies Division Erasmusstraße 14 D-103 Berlin Tel.: +49 (0) Fax: +49 (0) zentrale.berlin@reo.de REO Drives Division Holzhausener Straße 2 D Kyritz Tel.: +49 (0) Fax: +49 (0) info@reo.de REO Medical and Current Transformer Division Schuldholzinger Weg 7 D Pfarrkirchen Tel.: +49 (0) Fax: +49 (0) info@reo.de REO Test and PowerQuality Division Brühler Straße 100 D-4267 Solingen Tel.: +49 (0) Fax: +49 (0) info@reo.de PRODUCTION + SALES: China REO Shanghai Inductive Components Co., Ltd No. 36 ShangFeng Road Pudong, Shanghai China Tel.: +86 (0) Fax: +86 (0) info@reo.cn Internet: India REO GPD INDUCTIVE COMPONENTS PVT. LTD 2/202 Luna Road Village Luna Taluka Padra Vadodara India Tel.: +91 (2662) , +91 (26) Fax: +91 (26) info@reogpd.com Internet: USA REO-USA, Inc. 840 E. 47th St USA-Indianapolis, IN Tel.: +1 (317) Fax: +1 (317) info@reo-usa.com Internet: SALES: France REO VARIAC S.A.R.L. ZAC Du Clos aux Pois 1 6/8 rue de la Closerie-LISSES F Evry Cédex Tel.: +33 (0) Fax: +33 (0) reovariac@reo.fr Internet: Great Britain REO (UK) Ltd. Units 2-4 Callow Hill Road Craven Arms Shropshire SY7 8NT UK Tel.: +44 (0) Fax: +44 (0) main@reo.co.uk Internet: Italy REO ITALIA S.r.l. Via Treponti, 29 I-2086 Rezzato (BS) Tel.: Fax: info@reoitalia.it Internet: Poland REO CROMA Sp.zo.o ul. Pozaryskiego 28, bud 20 PL Warszawa Tel.: +48 (0) Fax: +48 (0) croma@croma.com.pl Internet: Spain REO ESPAÑA 2002 S.A. C/Curt, 2-2 bis Vilassar de Mar Barcelona Tel.: info@reospain.com Internet: Switzerland REO ELEKTRONIK AG Im Halbiacker a CH-832 Elsau Tel.: +41 (0) Fax: +41 (0) info@reo.ch Internet: Turkey REOTURKEY ELEKTRONIK San. ve Tic. Ltd. Şti. Halil Rıfatpasa Mah. Darülceze CD Perpa Tic Merkezi B Blok Kat 8 No:109 TR Sisli Istanbul Tel.: +90 (0) Fax: +90 (0) info@reo-turkey.com Internet:

NEW. REOWAVE passive The new generation of harmonic filters

NEW. REOWAVE passive The new generation of harmonic filters REOWAVE passive The new generation of harmonic filters NEW -Overcurrent indication signal -Temperature monitoring -Potential-free signal contact -Reactive poweroptimization REOWAVE passive The new generation

More information

REOWAVE passive The new generation of harmonic filters

REOWAVE passive The new generation of harmonic filters WAVE passive The new generation of harmonic filters WAVE passive The new generation of harmonic filters Electrical components are continually becoming smaller, more efficient and cheaper. To achieve this,

More information

High ingress protection ratings make a difference REO EMC-Filter with IP66

High ingress protection ratings make a difference REO EMC-Filter with IP66 High ingress protection ratings make a difference REO EMC-Filter with IP High protection classes up to IP for REO EMC filter The use of electrical and electronic equipment continues to increase, for example

More information

CNW Hz REOWAVEpassive - harmonic filter 60 Hz/480 V (IP20)

CNW Hz REOWAVEpassive - harmonic filter 60 Hz/480 V (IP20) Descripción Reduce Harmonics - save up to 30% energy costs. The REOWAVE passive filters harmonics caused by the B6 circuit (thyristor, diode bridge, etc.) and motor drives. The supply network is relieved

More information

Energy Regeneration V05/08

Energy Regeneration V05/08 Energy Regeneration V05/08 Introduction Often motor-driven dynamic systems with either large, rotating masses or used for moving heavy weight loads, build up high levels of kinetic or potential energy

More information

Pure Power Perfection

Pure Power Perfection Pure Power Perfection REO - Pure Power Perfection since 1925 Founded: 1925 Turnover: 28 million Euros (2007) Number of employees: 350 Equity ratio: 37,8 % (2007) Ownership: REO is a 100% family business

More information

REOTRON Electronic Power Controller MDW Phase-Thyristor Power Controller

REOTRON Electronic Power Controller MDW Phase-Thyristor Power Controller REOTRON Electronic ower Controller MDW 700 3-hase-Thyristor ower Controller MDW_700_EN_ANL_34-13.doc 21.08.2013 Contents Technical Information for the User... 2 1.0 General... 3 2.0 Construction... 3 3.0

More information

years old German company involved in above mentioned two organizations for all Organization :- REO-GPD is supported by workforce of 15 workers.

years old German company involved in above mentioned two organizations for all Organization :- REO-GPD is supported by workforce of 15 workers. Company Profile 2/202, LUNA ROAD, VILLAGE LUNA, TALUKA PADRA, DIST. VADODARA - 391440 GUJARAT, INDIA Phone No:- 02662-221723 0265-2396148 Fax:- 0265-2396971 E-Mail:- info@reogpd.com Web site:- www.reogpd.com

More information

FINHRM FINHRM5 FINHRMA FINHRMAC

FINHRM FINHRM5 FINHRMA FINHRMAC HARMONIC FILTERS Power quality is a significant concern for manufacturing and power generation facilities. This is due to harmonic disturbance and reactive power, which is produced by unbalanced loads,

More information

RELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES

RELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES RELIABLE SOLUTIONS in POWER ELECTRONICS RDAT SERIES Power Management Instruments BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES BATTERY CHARGER / DC RECTIFIER RDA / RDAT AUTOMATION

More information

Ultra Sine Inverter (US) Generation 4 (G4) User Guide

Ultra Sine Inverter (US) Generation 4 (G4) User Guide IBS Intelligent Battery System GmbH Seestrasse 24, CH-3600 Thun, Schweiz Tel: +41 33 221 06 16 Fax: +41 33 221 06 17 E-Mail: info@ibs-tech.ch Ultra Sine Inverter (US) Generation 4 (G4) User Guide IBS-USG4_en_v2.0.3.doc

More information

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A. LCL FILTERS INSTRUCTIONS MANUAL (M98121701-03-09A) (c) CIRCUTOR S.A. ------ LCL filters: Instructions Manual ----- Page 2 TABLE OF CONTENTS TABLE OF CONTENTS 2 1 CHECKS ON RECEIPT OF THE EQUIPMENT. 3 2

More information

Operating manual UPS - System

Operating manual UPS - System Operating manual UPS - System POWERMASTER M MIL 1000VA 7Min. BAX 3330 E UPS-Division Issued 15. August 2006 JOVYATLAS JOVYATLAS Elektrische Umformtechnik GmbH Groninger Straße 29-37 D-26789 Leer/Ostfriesland

More information

Technical information No. 01. IT systems. The basis for reliable power supply

Technical information No. 01. IT systems. The basis for reliable power supply IT systems The basis for reliable power supply FA01en/01.2004 IT systems The basis for reliable power supply in critical areas The advantages of sophisticated industrial systems can only be of use, if

More information

Safety Sensor CSS 180 Product Information

Safety Sensor CSS 180 Product Information Safety Sensor CSS 180 Product Information Safety Sensor CSS 180 CSS180CSS 180 PDF-M / EN 60947-5-3 EN 954-1 Control Category 4 IEC 61508, suitable for use in SIL 3 applications BG Type-Certification in

More information

ASHRAE - Variable Speed Drives. By Dan Watkins, LEED BD+C Bornquist, Inc.

ASHRAE - Variable Speed Drives. By Dan Watkins, LEED BD+C Bornquist, Inc. ASHRAE - Variable Speed Drives By Dan Watkins, LEED BD+C Bornquist, Inc. Adjustable Frequency Drive Fundamentals How does a VFD actually work VS Pumping Analysis VS Pumping Features Harmonics VFDs and

More information

Electronic Ballast EVG 2000-T

Electronic Ballast EVG 2000-T Electronic Ballast EVG 2000-T Operating Manual Table of contents 1 Description 1.1 Advantages of this ballast... 3 1.2 Functional principle... 3 1.3 Energization... 4 1.4 Visualization... 5 1.5 Indications

More information

Product Flyer ELC ELECTRONIC LAMP CONTROL

Product Flyer ELC ELECTRONIC LAMP CONTROL Product Flyer ELC ELECTRONIC LAMP CONTROL ELC General Information The electronic lamp control units ELC are designed to power UV medium pressure discharge lamps. In different series we offer fully integrated

More information

Appendix: Safety and application notes for... 15

Appendix: Safety and application notes for... 15 Contents Safety... 2 Warnings... 2 Symbols used in this manual... 2 Operator s safety... 2 Avoid filter module damage... 2 DC-link resonance... 2 Description... 3 Description... 3 Ordering numbers, 380-415

More information

ABB n.v Power Quality in LV installations

ABB n.v Power Quality in LV installations ABB n.v. - 1 - Power Quality in LV installations PQ problems in LV installations 750 500 250 Volts 0-250 -500 Amps -750 3000 2000 1000 0-1000 -2000-3000 10:25:43.72 10:25:43.73 10:25:43.74 10:25:43.75

More information

Transforming Energy.. For Advanced Technology

Transforming Energy.. For Advanced Technology Transforming Energy.. Manufacturers of CE approved Transformers & Reactors Five Decades of Manufacturing Experience Manufacturers of Quality Reliable Transformers. Auto C 201,4 th Cross Peenya Induatrial

More information

ADDITIONAL EMERGENCY POWER SUPPLY DEVICES

ADDITIONAL EMERGENCY POWER SUPPLY DEVICES ADDITIONAL EMERGENCY POWER SUPPLY DEVICES ADDITIONAL EMERGENCY POWER SUPPLY DEVICES OP Emergency power supplies according to VDE 0107 ZSV installations according to VDE 0107 AREAS OF USE Hospitals Out-patient

More information

AUTOMATIC CAPACITOR BANK WITH CONTACTOR OPERATIONS

AUTOMATIC CAPACITOR BANK WITH CONTACTOR OPERATIONS AUTOMATIC CAPACITOR BANK WITH CONTACTOR OPERATIONS INSTRUCTION MANUAL (M98125401-03 / 03A) (c) CIRCUTOR S.A. ------Automatic capacitor bank with contactor operations ----- Page 2 TABLE OF CONTENTS 1. Introduction.

More information

ELECTRIC TRACTION.

ELECTRIC TRACTION. ELECTRIC TRACTION www.koncar.hr MODERNISATION ELECTRIC TRACTION VEHICLES Company KON AR - ELECTRIC VEHICLES Inc. upgrades electric locomotives, electric multiple unit and electric tramcars. Upgrading proceedings

More information

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER INSTALLATION AND MAINTENANCE INSTRUCTIONS Risk of electric shock: Motor terminals may still be live if the impeller is rotating, even when

More information

VFD Best Practices: Getting the Most from Your VFD Investment

VFD Best Practices: Getting the Most from Your VFD Investment TECH TOPICS VFD Best Practices: Getting the Most from Your VFD Investment The purpose of this document is to outline best practices for successful application and installation of VFDs. Following these

More information

Softstarters Softstarters

Softstarters Softstarters , PSS & PST(B), PSS & PST(B) Low Voltage Products & Systems 6.1 General information PSR PSS From the moment the first electrical motors appeared, engineers have been searching for a way to avoid electrical

More information

Glossary/Technical appendix

Glossary/Technical appendix Contents Power Supplies Overview.2 Standards and approvals.4 Glossary.6 1460790000 2014/2015.1 Power Supplies Overview Power Supplies Overview Power supplies are important links in the energy supply chain

More information

Technical data sheets

Technical data sheets GE Consumer & Industrial Power Protection Technical data sheets Digital Energy Uninterruptible Power Supply LP 11 Series / 3 5 6 8 10 kva A product by: GE Consumer & Industrial SA General Electric Company

More information

Power Electronics. MINISTOP Motor Brake Relay BA 9034N

Power Electronics. MINISTOP Motor Brake Relay BA 9034N Power Electronics IISTOP otor Brake Relay BA 9034 0256981 Your advantages Higher safety level and more economic by short stopping cycle Cost saving Compact design Easily appliance, no need for current

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work REC EPO STATUS BAT OUTPUT MUTE Critical Power Technical Data Sheet Uninterruptible Power Supply TLESM_UL_015-090_UPS front_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)

More information

Industrial PFC UPS System

Industrial PFC UPS System Based on Statron s leading A.T.I.S. (Advanced Technology Industrial System) platform, the S3000 range is a true-industrial UPS system using the latest Power Factor Corrected (PFC) IGBT rectifier technology.

More information

EFFEKTA Power Supplies

EFFEKTA Power Supplies EFFEKTA GENERAL INFORMATION UPS topology ON LINE - Double Conversion Classification VFI-SS-111 in accordance with IEC 62040-3 Nominal output power (Cos Ø 0,9) - kva 10 15 20 30 40 Nominal output power

More information

STEPPER-BLOCKplus. Manual. Version: 2.0 As of: 06/2002 Author: Edmund Burger &RPSDFW6WHSSHU'ULYHU IRU3KDVH6WHSSLQJ0RWRUV. Main. Status-LED.

STEPPER-BLOCKplus. Manual. Version: 2.0 As of: 06/2002 Author: Edmund Burger &RPSDFW6WHSSHU'ULYHU IRU3KDVH6WHSSLQJ0RWRUV. Main. Status-LED. Manual STEPPER-BLOCKplus &RPSDFW6WHSSHU'ULYHU IRU3KDVH6WHSSLQJ0RWRUV Main Status-LED Current Adjustment Controller Motor Version: 2.0 As of: 06/2002 Author: Edmund Burger All rights reserved: MOTRON Steuersysteme

More information

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Presentation Soft starters 0 Altistart 48 soft start - soft stop units Presentation Soft starters 5 6 7 65_Ver.-EN.fm/ Presentation (continued) Soft starters Applications The Altistart 8 soft start - soft stop unit is a controller with 6 thyristors which is used for the torque-controlled

More information

PRS 9. Installation Instructions Cycling Timer PRS 9. A Siebe Group Product 1

PRS 9. Installation Instructions Cycling Timer PRS 9. A Siebe Group Product 1 PRS 9 Installation Instructions 810407-00 Cycling Timer PRS 9 A Siebe Group Product 1 Dimensions / Parts Drawings 128.5 169 30.01 (6TE) Fig. 1 A B C D E I H G J F MAX 70 C Fig. 2 MAX 95 % 2 Key A B C D

More information

Easy Choice for Energy Efficiency

Easy Choice for Energy Efficiency Easy Choice for Energy Efficiency EasyCan The new generation LV power factor correction capacitors EasyCan The new generation LV power factor correction capacitors What is power factor correction? In electrical

More information

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference ❶ Performance Data Pages

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Coordinate starter needs for mechanical equipment prior to 50% CD and confirm again for 100% CD submittal. B. Coordinate temperature controls requirements

More information

Technical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids

Technical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids Technical Data Low Voltage Regulation System LVRSys 1 Power range: 7.5 kva up to 3150 kva 1 Regulation: single- or three-phase 1 Regulation ranges: ± 6 % to ± 24 % 1 Overall efficiency: 99.4 % to 99.8

More information

User Guide 4Q kW D.C.Motor Regenerative Speed Controller. Part Number: Issue Number: 3

User Guide 4Q kW D.C.Motor Regenerative Speed Controller. Part Number: Issue Number: 3 User Guide 4Q2 0.55-7.5kW D.C.Motor Regenerative Speed Controller Part Number: 0400-0042-03 Issue Number: 3 General Information The manufacturer accepts no liability for any consequences resulting from

More information

Filters for Converters and Power Electronics

Filters for Converters and Power Electronics Filters for Converters and Power Electronics Collection 2000 http://www.epcos.com EMC filters are indispensable in industrial installations when it comes to preventing RF disturbance in order to ensure

More information

SUN INGECON. Box 220 / 275 / 300 / 320 / 345 / 360 Vac. M220 / M275 / M300 / M320 / M345 / M360 Outdoor.

SUN INGECON. Box 220 / 275 / 300 / 320 / 345 / 360 Vac. M220 / M275 / M300 / M320 / M345 / M360 Outdoor. Box 220 / 275 / 300 / 320 / 345 / 360 Vac M220 / M275 / M300 / M320 / M345 / M360 Outdoor INVERTERS FOR OUTDOOR INSTALLATION, IDEAL FOR MULTI-MEGAWATT PV PLANTS Designed for outdoor installation Suitable

More information

Electronic Circuit Breaker ESS20

Electronic Circuit Breaker ESS20 Electronic Circuit Breaker ESS20 Description Electronic circuit breaker type ESS20 is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 24 V switch-mode

More information

EDB6032_G/GB Antriebstechnik. Operating Instructions. Brake chopper 6032/6033/6034

EDB6032_G/GB Antriebstechnik. Operating Instructions. Brake chopper 6032/6033/6034 EDB6032_G/GB 00376698 Antriebstechnik Operating Instructions Brake chopper 6032/6033/6034 These operating instructions are valid for the devices with the nameplate data: 6032_G.2E 6033_G.2E 6034_G.1A Type

More information

ELECTRICAL TEST SOLUTIONS. Continuously variable control of voltage, current and power

ELECTRICAL TEST SOLUTIONS. Continuously variable control of voltage, current and power ELECTRICAL TEST SOLUTIONS Continuously variable control of voltage, current and power As an internationally established brand in the area of test engineering systems we bear a special responsibility. Our

More information

Variable speed application guidelines

Variable speed application guidelines Variable speed application guidelines Frequency converter VLT 00 SCROLL COMPRESSORS REFRIGERATION AND AIR CONDITIONING www.danfoss.com Introduction The introduction of speed control for refrigeration

More information

Power Factor Correction

Power Factor Correction Power Factor Correction It's all about saving your money! Features that matter n Overcurrent up to 2.2 times rated current n Inrush current up to 300 times rated current n Self-healing type, segmented

More information

Protective firing in LCC HVDC: Purposes and present principles. Settings and behaviour. V. F. LESCALE* P. KARLSSON

Protective firing in LCC HVDC: Purposes and present principles. Settings and behaviour. V. F. LESCALE* P. KARLSSON 21, rue d Artois, F-75008 PARIS B4-70 CIGRE 2016 http : //www.cigre.org Protective firing in LCC HVDC: Purposes and present principles. Settings and behaviour. V. F. LESCALE* P. KARLSSON VILES Consulting

More information

Power Quality and Energy Management

Power Quality and Energy Management Power Quality and Energy Management 1 2 Contents Power Quality...2 Power Factor Correction...4 Voltage Optimisation...8 Harmonic Filters and Reactors...12 1 Captech is Power Investigation and identification

More information

Switching Power Supply

Switching Power Supply Switching Power Supply Easy-to-use Industrial Power Supply with Versatile Functions (); Power Supply Suitable for Peak Loads such as Motors and Solenoids (-P) Remote control function incorporated. Remote

More information

Instruction Manual. Harmonic Filter AHF 005/010. Drives Solutions

Instruction Manual. Harmonic Filter AHF 005/010. Drives Solutions Harmonic Filter AHF 005/010 Instruction Manual Drives Solutions Contents Safety... 2 Warnings... 2 Symbols used in this manual... 2 Operator s safety... 2 Avoid filter module damage... 2 DC-link resonance...

More information

Abstract. Benefits and challenges of a grid coupled wound rotor synchronous generator in a wind turbine application

Abstract. Benefits and challenges of a grid coupled wound rotor synchronous generator in a wind turbine application Issue #WP102: Technical Information from Cummins Generator Technologies Benefits and challenges of a grid coupled wound rotor synchronous generator in a wind turbine application White Paper Ram Pillai

More information

Start-up instructions

Start-up instructions E l e k t r o n i k s y s t e m e G m b H Development and production of electronical systems Eichelreuth 13 Phone: +49 8641 598360 83224 Grassau Fax: +49 8641 598364 E-Mail: info@rs-steiner.com Internet:

More information

DEVICE STATE/BYPASSED FAILURE OVERLOAD

DEVICE STATE/BYPASSED FAILURE OVERLOAD Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated

More information

Phase Modular Finally the benefits of Modular ups are for all

Phase Modular Finally the benefits of Modular ups are for all MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 The MUST 30/120 is an uninteruptible power supply, three phase input/ output, ranging from 15 kva to 120 kva

More information

Cooling Systems for Rolling Stock

Cooling Systems for Rolling Stock Cooling Experts Around the Globe Cooling Systems for Rolling Stock Cooling tower for combined cooler for transformator oil and coolant DE DIESEL-ELECTRIC-LOCOMOTIVES AKG cooling towers installed in diesel

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail

More information

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen. Power Conversion Systems 2005/2006 Schaefer the Power to make it happen. Company profile workforce experience customer orientation flexibility reliability Schaefer Elektronik, founded in 1969, has grown

More information

Isolation Transformer for Medical Applications

Isolation Transformer for Medical Applications User Instructions Isolation Transformer for Medical Applications Type: Isolation Transformers REOMED 300VA; REOMED 600VA; REOMED 1000VA REO (UK) Limited Units 2 4 Callow Hill Road, Craven Arms Business

More information

Enclosed switches. from 20 to 1600 A

Enclosed switches. from 20 to 1600 A Enclosed switches from 20 to 1600 A Why do you need an enclosed switch? Switchgear systems are an essential part of your electrical system. Present at all levels of your electrical distribution, they allow

More information

Chapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design

Chapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design Dynamic power factor correction systems (real time PFC) Optimised, thermal design Long service life De-tuned version Minimised grid distortion Dynamic power factor correction systems (real time PFC) Hardly

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 150 200 250 300 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric

More information

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM 106 CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM 5.1 INTRODUCTION Inherent characteristics of renewable energy resources cause technical issues not encountered with conventional thermal,

More information

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES KEOR HP THREE-PHASE from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Legrand SUPERIOR PERFORMANCE SERVICE CONTINUITY AND ENERGY EFFICIENCY Legrand, world leader

More information

Unit Protection System for Pumped-Storage Power Stations

Unit Protection System for Pumped-Storage Power Stations Unit Protection System for Pumped-Storage Power Stations 1. Introduction In many power systems, pumped-storage power stations are used in addition to run-of-river power stations. These power stations serve

More information

smartvar Dynamic VAR Compensator

smartvar Dynamic VAR Compensator smartvar Dynamic VAR Compensator DOES YOUR BUSINESS NEED TO SAVE MONEY? Discover a quick and easy way to identify cost saving opportunities. Improve the dynamic processes in your facility with smartvar.

More information

Valve monitoring system VDK 200 A S02

Valve monitoring system VDK 200 A S02 Valve monitoring system VDK 200 A S02 8.11 Printed in Germany Edition 11.17 Nr. 214 768 1 6 Technical description The VDK 200 A S02 is the compact valve monitoring system as per EN 1643 for automatic shut-off

More information

Asynchronous generators

Asynchronous generators Asynchronous generators Contents Product description 13/2 Overview of technical data 13/3 Motor selection data Series G4.R on the basis of Premium Efficiency IE3 13/4 Series GE.R on the basis of High Efficiency

More information

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130 Operating Manual (Edition 04/2004) sinamics Braking Module / Braking Resistor SINAMICS G130 04/04 Contents Contents 1 Safety Information 1-1 2 General 2-1 3 Mechanical Installation 3-1 4 Connection 4-1

More information

GEPA. ARG-24 Series Battery Charger & Battery Group. User Guide

GEPA. ARG-24 Series Battery Charger & Battery Group. User Guide GEPA ARG-24 Series Battery Charger & Battery Group User Guide Contents 1. General... 1 2. Features... 2 3. Montage & Wiring... 3 3.1. Montage... 3 3.2. Wiring... 4 4. Usage... 5 4.1. Interface... 5 4.1.1.

More information

Operating instructions Flow monitors SI5000 SI / / 2007

Operating instructions Flow monitors SI5000 SI / / 2007 Operating instructions Flow monitors SI5000 SI5001 704056 / 01 06 / 2007 Contents 1 Safety instructions... 3 2 Functions and features... 4 2.1 Application area... 4 2.2 Operating principle flow monitoring...

More information

SDC,Inc. SCR-Regenerative Ac Drive

SDC,Inc. SCR-Regenerative Ac Drive SDC,Inc WWW.STEVENSDRIVES.COM APPLICATION NOTE #: AN_REG_GEN000 EFFECTIVE DATE: 12 MAR 02 SUPERSEDES DATE: Original NO. OF PAGES: 10 SCR-Regenerative Ac Drive Using a regeneration controller with adjustable-frequency

More information

Control Box CB12. Data sheet LINAK.COM/MEDLINE-CARELINE

Control Box CB12. Data sheet LINAK.COM/MEDLINE-CARELINE Control Box CB12 Data sheet LINAK.COM/MEDLINE-CARELINE CB12 The CB12 product range features two standard versions, which are ideal for a vast number of medical and industrial applications. In general the

More information

amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT

amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT amp ramp Operators Manual Saftronics S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD 6QT Tel: 0484 530893 Fax: 0484 550500 Website:www.saftronics.co.uk E-Mail: sales@saftronics.co.uk

More information

Operating instructions Flow monitors SI / / 2010

Operating instructions Flow monitors SI / / 2010 Operating instructions Flow monitors SI5004 UK 704339 / 02 08 / 2010 Contents 1 Safety instructions 3 2 Functions and features 4 2.1 Application area 4 2.2 Operating principle flow monitoring 4 3 Installation

More information

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES KEOR HP THREE-PHASE from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Legrand SUPERIOR PERFORMANCE SERVICE CONTINUITY AND ENERGY EFFICIENCY Legrand, world leader

More information

MAHA Two Post Lifts. Model: ECON III 3.0 ECON III 3.5 ECON III 4.0 ECON III 5.0 HL III 4.0 HL III 5.0. Lifting Technology

MAHA Two Post Lifts. Model: ECON III 3.0 ECON III 3.5 ECON III 4.0 ECON III 5.0 HL III 4.0 HL III 5.0. Lifting Technology Wir im Allgäu. MAHA Two Post Lifts Model: ECON III 3.0 ECON III 3.5 ECON III 4.0 ECON III 5.0 HL III 4.0 HL III 5.0 Lifting Technology DIN EN ISO 9001:2008 ISO 14001:2004 SINCE 1969 For passenger cars

More information

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms) LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTRES BM Plus Series BMLM 10-20 kva Single-phase BMLT 10-120 kva Three-phase CASH REGISTERS TELECOM- MUNICATIONS DEVICES E-BUSINESS (Servers Farms, ISP/ASP/POP)

More information

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM Contents Section Page 1.0 Introduction 1 2.0 Specification 1-4 3.0 Installation 5-8 4.0 Programming 9-10 5.0 Menus 10-12 6.0 Fault Finding/Diagnostics 12-13 7.0 Communication 13 8.0 Setting Up 13-16 1.0

More information

COMBIVERT R6 MADE IN. Line Regen Systems Up to 1000 kva

COMBIVERT R6 MADE IN. Line Regen Systems Up to 1000 kva R6 COMBIVERT R6 MADE IN GERMANY Line Regen Systems Up to 1000 kva KEB COMBIVERT R6 - Philosophy The kinetic energy of electric drives can be a valuable energy potential. Historically, that kinetic energy

More information

Product information. ECOSS Electronic compact starter for wound rotor drives

Product information. ECOSS Electronic compact starter for wound rotor drives Product information ECOSS Electronic compact starter for wound rotor drives Controlled and safe start-up of wound rotor drives Electronic compact starters are used when slip-ring motors have to be started

More information

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids Technical Information Soliphant T FTM260 Level limit switch Cost-effective vibration limit switch for fine-grained solids Application Soliphant is a rugged level limit switch for use in silos containing

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL) LINEAR LED DRIVERS ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL) 186443, 186444, 186486, 186487, 186488, 186491, 186492, 186737 Typical Applications Built-in in linear luminaires for Office lighting

More information

NEW. Heavy Duty Capacitors. Power Factor Correction Capacitors Type LKT. It s all about saving your money! Features that matter:

NEW. Heavy Duty Capacitors. Power Factor Correction Capacitors Type LKT. It s all about saving your money! Features that matter: LKT Heavy Duty s NEW Overcurrent up to 2.7 times rated current Inrush current up to 450 times rated current Mean Life expectancy: 200,000 h. Up to 100,000 annual switching operations Features that matter:

More information

Power ratings Input voltage Output Voltage Output current Boost Current Model number 120 W 2-phase and 3-phase

Power ratings Input voltage Output Voltage Output current Boost Current Model number 120 W 2-phase and 3-phase New Product Switch Mode Power Supply S8VK-T (120/240/480/960 W Models) Worldwide 3-phase Power Supply Resistant in tough environments Easy and fast installation The most compact class on the market Wide

More information

Power Factor Correction Capacitors Type LKT

Power Factor Correction Capacitors Type LKT Power Factor Correction s LKT E337088 Features that matter: Handles continuous current up to 2.25 / 2.7 times rated current Withstands inrush current up to 375 / 450 times rated current Environment-friendly,

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

Energy Storage Solution for microgrids. from 33 kva to multiple MVA

Energy Storage Solution for microgrids. from 33 kva to multiple MVA Energy Storage Solution for microgrids from 33 kva to multiple MVA For a secure and flexible network Microgrids are groups of Distributed Energy Resources (DERS) and interconnected loads controllable as

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply TLESM_030-180_UPS front_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91

More information

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options /2 Overview /2 Benefits /2 Design /6 Function /8 Selection and ordering data /8 Options Technical data /1 General technical data /15 Control properties /15 Ambient conditions /16 Installation conditions

More information

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. System Universal LED dimming insert Standard

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. System Universal LED dimming insert Standard Order no.: 5400 00 Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible.

More information

Compact Energy Storage Module. Modular Systems, EPDS. Product overview

Compact Energy Storage Module. Modular Systems, EPDS. Product overview Compact Energy Storage Module Modular Systems, EPDS Product overview ABB Power Products in energy storage Portfolio coverage Stationary Application Focus ESM Load leveling Spinning reserve ESM Behind-the-meter

More information

Appendix: Safety and application notes for 19

Appendix: Safety and application notes for 19 Contents Safety 2 Warnings 2 Symbols used in this manual 2 Operator's safety 2 Avoid filter module damage 2 DC-link resonance 2 Description 3 Description 3 Ordering numbers, 380-415 V, 50 Hz 4 Ordering

More information

HARMONIC FILTER REACTOR

HARMONIC FILTER REACTOR 380V 50Hz Series Resonance Frequency : 204Hz or p = 6% To be used with 415V capacitor only Design : According to VDE 0550/0532 & IEC 76 l 250 = 0.31 x l N Testing : Insulation strength tested at 2.5kV

More information

Development of Small-capacity OFF-LINE UPS

Development of Small-capacity OFF-LINE UPS 1 / 5 SANYO DENKI TECHNICAL REPORT No.9 May-2000 Features: Technical Developments in 1999 Development of Small-capacity OFF-LINE UPS Chiaki Seki Hideaki Yoda Hideaki Matsuo Shigeo Ichikawa 1. Introduction

More information

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy GE Digital Energy Technical data sheet Uninterruptible Power Supply LP11 924 Series 6 & 10 kva gimagination at work GE T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www..com General data Topology VFI,

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 160 200 250 300 kva PurePulse TM 400 Vac CE Series 1 Date of issue: 15.02.2007 SGSE160-200S1UPS01

More information