NEW. REOWAVE passive The new generation of harmonic filters
|
|
- Gary Snow
- 5 years ago
- Views:
Transcription
1 REOWAVE passive The new generation of harmonic filters NEW -Overcurrent indication signal -Temperature monitoring -Potential-free signal contact -Reactive poweroptimization
2 REOWAVE passive The new generation of harmonic filters Fulfill with REOWAVEpassive the following standards: Electrical components are continually becoming smaller, more efficient and cheaper. To achieve this, most applications include components such as thyristors or frequency converters. The components are also known as non-linear loads because their characteristic curve is not a straight line, which leads to many u ndesirable problems. In particular, these include harmonics. Harmonics are an example of the type of problem that are often simply not recognised correctly, but can cause significant malfunctioning particularly with the increasing use of non-linear loads. Harmonics cause, for example, interference phenomena such as: Creating additional losses resulting in unnecessary consumption of energy Reduced lifetime of transformers due to destruction of the insulation Resonances in the supply networks Measurement errors Errors in tripping fuses Serious faults in IT systems. The solution for these problems is the REOWAVE passive! This device is used at the place where the problems arise where the biggest effect can be achieved. REOWAVE passive is based on proven components of the REO CNW family such as REO mains filters and REO harmonic filters which, thanks to their excellent characteristics and the special circuit design of REOWAVE passive, efficiently keep the harmonics away from the mains network. Netz Nichtlineare Last Netz Nichtlineare Last Mains Non-linear load Mains Non-linear load REO WAVE Diagram 1: Uncontrolled rectifier Diagram 2: Diode rectifier with REOWAVE passive Diagram 3: Current (blue) und voltage (red) for a B6 rectifier configuration with scaled values Diagram 4: Current (blue) und voltage (red) for a B6 rectifier with REOWAVE passive; scaled values
3 REOWAVE passive Save money with less reactive power In the course of rising energy costs and growing CO 2 emissions minimizing losses in the transmission grid gains more and more importance. An important factor are the reactive currents. These currents do not contribute to the effective power, but stress all components in the current path and cause additional losses to the ohmic resistance component of the lead. Reactive currents are, for example, harmonics caused by the usage of frequency. However, reducing the energy efficiency is not only a burden on the environment because more energy is consumed for a steady performance - at the same time the costs increase for the operator of the installations, as they have to pay the reactive power. Mains chokes, DC chokes or Harmonicfilter of REO filter unwanted harmonics and help to counteract the resulting reactive current. Thus, the reactive power is diminished, the energy requirement and the running costs are reduced. Measurements at a frequency converter of 22 kw to the motor shaft Non unfiltered filtro Induttanza 1% Ukmains 1%Uk di linea Induttanza 2% Ukmains 2%Uk di linea Induttanza 4% Ukmains 4%Uk di linea REOWAVE passive Plus choke choke choke l input [A] 42,4 41,6 37,7 3,8 32,0 Q [kvar] 19,6 18,0 1,2 10,2 2, Current and power factor at a REOWAVE passive CNW 8981 / A / 400V / 0Hz Our favorite: REOWAVE passive - save up to 30% energy
4 REOWAVE passive REOWAVE passive harmonic filter with a potential for savings REOWAVE passive doesn t only give protection against harmonics significant reduction of costs is also possible. The way that REOWAVE passive works results in reductions in current and current harmonics, enabling significantly smaller fuses, cabling and transformers to be used. REOWAVE passive therefore enables not only energy cost savings but also savings in equipment costs. Measurement on a converter without REOWAVE passive Measurement on a converter with REOWAVE passive Current 2,7 A I 67 % I7 43 % THDI 81% Current 19,7 A I 2,7 % I7 1,8 % THDI 4,4 REOWAVE passive approved REO quality l [A] 22,00 20,00 18,00 16,00 14,00 12,00 12,00 10,00 10,00 8,00 8,00 6,00 6,00 4,00 4,00 Converter without REOWAVE passive Converter with REOWAVE passive Limit value by EN REOWAVE passive is a filter unit which consists out of approved REO CNW components. This filter unit includes a REO mains filter and a REO harmonics filter. The mains filters function is the pre-supression of the mains as well as the shielding against external harmonics. It filters the harmonics caused by the B6 circuit (thyristor, diode bridge etc.), effects a preliminary suppression of network interference, screens the application from extraneous harmonics and enables a cost-saving in equipment selection and energy consumption. Mains Netz Non-linear Nichtlineare loadlast 2,00 2,00 0,00 0, Harmonics REO WAVE REO Mains Netzfilter REO Oberwellen- Harmonics filter Umrichter/ Prüfling Non-linear Nichtlineare loadlast Mains Netz Image 1: The design allows for the parallel connection of two REOWAVE passive to increase the power capacity. Mains Netz REO WAVE Non-linear Nichtlineare load Last Image 2: Naturally several nonlinear loads can be suppressed with a single REOWAVE passive. The filter must merely be suitably rated for the required power. REO WAVE REO WAVE
5 The REOWAVE passive Energy saving up to 30% The REOWAVE passive filters harmonics, and ensures: Reduction of the THDI value Monitoring and shutdown - temperature and filter circuit supervision Increasing network stability Onsite measurement of power failures Reduction of current consumption Reduction of equipment costs Customized Power Quality solutions Simple integration into existing systems Calculate your savings Increase of operational safety REOWAVE passive-energy saving calculator Calculation of your savings by the REOWAVE passive energy saving calculator. With your operating data the savings.
6 The REOWAVE passive Plus Automatically monitor filter performance - more security for your systems NEW -Overcurrent indication signal -Temperature monitoring -Potential-free signal contact -Reactive poweroptimization Green 80% Load Yellow 100% Load Red >10% Load -REOWAVE passive Plus - Reduce power consumption by approx. 20% The REOWAVE passive can also be supplied as a REOWAVE passive plus to the basic equipment, including the following additional options: Overcurrent indication signals Temperature monitoring Floating signalling contacts Automatic disconnection of the filter in the event of a system problem Switching the filter circuit off / on for reactive power optimization The options allow optimisation of the mains network quality and overall system security and allow better monitoring by a PLC or supervisory system. Overcurrent indication signal The REOWAVE passive includes compact measurement and monitoring electronics, which constantly measure the current and indicates status accordingly GREEN = power consumption approx 80% (based on the rated current of the filter) YELLOW = power consumption approx 100% (based on the rated current of the filter) RED = power consumption above 10% (based on the rated current of the filter) The status is signalled via a potential-free signal contact and may initiate further action.
7 The REOWAVE passive Plus Reactive power optimization - reduce additional costs PE L1 L2 L3 Mains Mains choke Load PE L1 L2 L3 Display Current 10% Red 100% Yellow 80% Green Logic module Absorption circuit Signals Fan Overtemperature Overcurrent 230 V Fan Principle of operation REOWAVE passive Temperature monitoring Bespoke electronics monitor the operating temperature of the inductive components, used within the filter. If these exceed the safe operating temperature, a potential-free contact will indicate this. Disconnection of the filter function in case of failure If an overtemperature condition is discovered the mains is automatically disconnected after a pre-determined delay in order to avoid permenant system damage. All error messages are reset when the power is again returned to the rated operating condition. Reactive power optimization In order to optimize the reactive power, the filter circuit is only switched on from a certain current, preventing a reactive current component through the filter choke Optionally with corresponding plugs and sockets for immediate use without large installations, - like that, immediate beginning of the savings! Specially developed control circuitry in the REOWAVE passive Plus ensures optimum performance, not only is the unit protected in the case of Overtemperature and Overload but it can also be safely used in the start-up mode of a Variable Speed Drive, by bypassing the internal shunt element of the circuit. This minimize the absorbed reactive power and protects the internal REOWAVE passive filter capacitors. The absorbed reactive power is reduced over the entire range by 30%.
8 REOWAVE passive: Application and markets Refineries and pumps Renewable energies Lifts and escalators Electrical drives Conveyor systems Whatever moves you. Whatever you move. Please contact us. We re here to help.
9 REOWAVE passive 400 V / 0 Hz Electrical and mechanical data Insulation class: F Climate class: 2/08/21 DIN IEC 68 Teil 1 Ambient temperature: 40 C Protection: IP 00 The components are delivered as separate components for customer mounting Typ CNW/ Image Nr. Choke1/ Choke2 Rated current [A] Losses [W] L B/ B2 Chokes 1 Chokes 2 Capacitors H N1 N2 L B H N1 N2 L B H N1 N2 N3 N4 Weight [kg] 8981/6 8981/ / / / /4 8981/ 8981/ / / / / / / / / /0 8981/ , , , , , , , , , , , *All variants also available as REOWAVEpassive Plus 8981/ Due to the special conception a special design is required - please contact us!
10 REOWAVE passive 480 V / 60 Hz Electrical and mechanical data Insulation class: F Climate class: 2/08/21 DIN IEC 68 Teil 1 Ambient temperature: 40 C Protection: IP 00 The components are delivered as separate components for customer mounting Typ CNW/ Image Nr. Choke1/ Choke2 Rated current [A] Losses [W] L B/ B2 Chokes 1 Chokes 2 Capacitors H N1 N2 L B H N1 N2 L B H N1 N2 N3 N4 Weight [kg] 8981/ / / / /4 8981/ 8981/ / / / / / / / / /0 8981/ , , , , , , , , , , *All variants also available as REOWAVEpassive Plus 8981/ Due to the special conception a special design is required - please contact us!
11 REOWAVE passive 690 V / 0 Hz Electrical and mechanical data Insulation class: F Climate class: 2/08/21 DIN IEC 68 Teil 1 Ambient temperature: 40 C Protection: IP 00 The components are delivered as separate components for customer mounting Typ CNW/ Image Nr. Choke1/ Choke2 Rated current [A] Losses [W] L B/ B2 Chokes 1 Chokes 2 Capacitors H N1 N2 L B H N1 N2 L B H N1 N2 N3 N4 Weight [kg] 8981/ / / / /4 8981/ 8981/ / / / / / / / / / / Protection IP 20 on request *All variants also available as REOWAVEpassive Plus
12 REOWAVE passive 400 V / 0 Hz Electrical and mechanical data Insulation class: F Climate class: 2/08/21 DIN IEC 68 Teil 1 Ambient temperature: 40 C Protection: IP 20 Different housings, depending on the power Type Image Nr. CNW 8981/6 1 CNW 8981/9 1 CNW CNW CNW 8981/22 2 CNW 8981/32 2 CNW 8981/36 2 CNW 8981/4 3 CNW 8981/ 3 CNW 8981/70 3 CNW 8981/90 4 CNW CNW CNW CNW 8981/200 CNW 8981/230 CNW 8981/270 CNW 8981/330 CNW 8981/370 CNW 8981/400 CNW 8981/40 CNW 8981/0 CNW 8981/60 CNW 8981/800 6 CNW CNW Rated current [A] Losses [W] Housing dimensions in mm L B H/H1 H2 N1 N2 N3 D Weight [kg] Terminals [mm²] Due to the special conception a special design is required - please contact us! *All variants also available as REOWAVEpassive Plus
13 REOWAVE passive 480 V / 60 Hz Electrical and mechanical data Insulation class: F Climate class: 2/08/21 DIN IEC 68 Teil 1 Ambient temperature: 40 C Protection: IP 20 Different housings, depending on the power Type Image Nr. Rated current [A] Losses [W] Housing dimensions in mm L B H/H1 H2 N1 N2 D Weight [kg] Terminals [mm²] CNW 8981/9 1 CNW CNW CNW 8981/22 2 CNW 8981/32 2 CNW 8981/36 2 CNW 8981/4 3 CNW 8981/ 3 CNW 8981/70 3 CNW 8981/90 4 CNW CNW CNW CNW 8981/200 CNW 8981/230 CNW 8981/270 CNW 8981/330 CNW 8981/370 CNW 8981/400 CNW 8981/40 CNW 8981/0 CNW 8981/60 CNW 8981/800 6 CNW CNW Due to the special conception a special design is required - please contact us! *All variants also available as REOWAVEpassive Plus
14 REOWAVE passive in IP 00 Image 1 - u D=7mm Image 2 - v D=7mm Image 3- w D=7mm CAPACITORS
15 REOWAVE passive in IP 20 Image 1 Image 2 Image 3 Image 4 Image Image 6
16 REO AG Brühler Straße 100 D-4267 Solingen Tel.: +49 (0) Fax: +49 (0) info@reo.de Internet: Divisions: REO Vibratory Feeding and Power Electronics Division Brühler Straße 100 D-4267 Solingen Tel.: +49 (0) Fax: +49 (0) info@reo.de REO Train Technologies Division Erasmusstraße 14 D-103 Berlin Tel.: +49 (0) Fax: +49 (0) zentrale.berlin@reo.de REO Drives Division Holzhausener Straße 2 D Kyritz Tel.: +49 (0) Fax: +49 (0) zentrale.kyritz@reo.de REO Medical and Current Transformer Division Schuldholzinger Weg 7 D Pfarrkirchen Tel.: +49 (0) Fax: +49 (0) zentrale.pfarrkirchen@reo.de REO Test and PowerQuality Division Brühler Straße 100 D-4267 Solingen Tel.: +49 (0) Fax: +49 (0) info@reo.de PRODUCTION + SALES: China REO Shanghai Inductive Components Co., Ltd info@reo.cn Internet: India REO GPD INDUCTIVE COMPONENTS PVT. LTD info@reogpd.com Internet: USA REO-USA, Inc. info@reo-usa.com Internet: SALES: France REO VARIAC S.A.R.L. reovariac@reo.fr Internet: Great Britain REO (UK) Ltd. main@reo.co.uk Internet: Italy REO ITALIA S.r.l. info@reoitalia.it Internet: Poland REO CROMA Sp.zo.o croma@croma.com.pl Internet: Spain REO ESPAÑA 2002 S.A. info@reospain.com Internet: Switzerland REO ELEKTRONIK AG info@reo.ch Internet: Turkey REOTURKEY ELEKTRONIK San. ve Tic. Ltd. Şti. info@reo-turkey.com Internet: Version_ _EN_1
REOWAVE passive The new generation of harmonic filters. NEW Overcurrent indication signal Temperature monitoring Potential-free signal contact
REOWAVE passive The new generation of harmonic filters NEW Overcurrent indication signal Temperature monitoring Potential-free signal contact REOWAVE passive The new generation of harmonic filters Fulfill
More informationREOWAVE passive The new generation of harmonic filters
WAVE passive The new generation of harmonic filters WAVE passive The new generation of harmonic filters Electrical components are continually becoming smaller, more efficient and cheaper. To achieve this,
More informationHigh ingress protection ratings make a difference REO EMC-Filter with IP66
High ingress protection ratings make a difference REO EMC-Filter with IP High protection classes up to IP for REO EMC filter The use of electrical and electronic equipment continues to increase, for example
More informationCNW Hz REOWAVEpassive - harmonic filter 60 Hz/480 V (IP20)
Descripción Reduce Harmonics - save up to 30% energy costs. The REOWAVE passive filters harmonics caused by the B6 circuit (thyristor, diode bridge, etc.) and motor drives. The supply network is relieved
More informationEnergy Regeneration V05/08
Energy Regeneration V05/08 Introduction Often motor-driven dynamic systems with either large, rotating masses or used for moving heavy weight loads, build up high levels of kinetic or potential energy
More informationPure Power Perfection
Pure Power Perfection REO - Pure Power Perfection since 1925 Founded: 1925 Turnover: 28 million Euros (2007) Number of employees: 350 Equity ratio: 37,8 % (2007) Ownership: REO is a 100% family business
More informationREOTRON Electronic Power Controller MDW Phase-Thyristor Power Controller
REOTRON Electronic ower Controller MDW 700 3-hase-Thyristor ower Controller MDW_700_EN_ANL_34-13.doc 21.08.2013 Contents Technical Information for the User... 2 1.0 General... 3 2.0 Construction... 3 3.0
More informationFINHRM FINHRM5 FINHRMA FINHRMAC
HARMONIC FILTERS Power quality is a significant concern for manufacturing and power generation facilities. This is due to harmonic disturbance and reactive power, which is produced by unbalanced loads,
More informationOperating manual UPS - System
Operating manual UPS - System POWERMASTER M MIL 1000VA 7Min. BAX 3330 E UPS-Division Issued 15. August 2006 JOVYATLAS JOVYATLAS Elektrische Umformtechnik GmbH Groninger Straße 29-37 D-26789 Leer/Ostfriesland
More informationLCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.
LCL FILTERS INSTRUCTIONS MANUAL (M98121701-03-09A) (c) CIRCUTOR S.A. ------ LCL filters: Instructions Manual ----- Page 2 TABLE OF CONTENTS TABLE OF CONTENTS 2 1 CHECKS ON RECEIPT OF THE EQUIPMENT. 3 2
More informationTechnical information No. 01. IT systems. The basis for reliable power supply
IT systems The basis for reliable power supply FA01en/01.2004 IT systems The basis for reliable power supply in critical areas The advantages of sophisticated industrial systems can only be of use, if
More informationTransforming Energy.. For Advanced Technology
Transforming Energy.. Manufacturers of CE approved Transformers & Reactors Five Decades of Manufacturing Experience Manufacturers of Quality Reliable Transformers. Auto C 201,4 th Cross Peenya Induatrial
More informationElectronic Ballast EVG 2000-T
Electronic Ballast EVG 2000-T Operating Manual Table of contents 1 Description 1.1 Advantages of this ballast... 3 1.2 Functional principle... 3 1.3 Energization... 4 1.4 Visualization... 5 1.5 Indications
More informationSafety Sensor CSS 180 Product Information
Safety Sensor CSS 180 Product Information Safety Sensor CSS 180 CSS180CSS 180 PDF-M / EN 60947-5-3 EN 954-1 Control Category 4 IEC 61508, suitable for use in SIL 3 applications BG Type-Certification in
More informationASHRAE - Variable Speed Drives. By Dan Watkins, LEED BD+C Bornquist, Inc.
ASHRAE - Variable Speed Drives By Dan Watkins, LEED BD+C Bornquist, Inc. Adjustable Frequency Drive Fundamentals How does a VFD actually work VS Pumping Analysis VS Pumping Features Harmonics VFDs and
More informationTechnical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids
Technical Data Low Voltage Regulation System LVRSys 1 Power range: 7.5 kva up to 3150 kva 1 Regulation: single- or three-phase 1 Regulation ranges: ± 6 % to ± 24 % 1 Overall efficiency: 99.4 % to 99.8
More informationAppendix: Safety and application notes for... 15
Contents Safety... 2 Warnings... 2 Symbols used in this manual... 2 Operator s safety... 2 Avoid filter module damage... 2 DC-link resonance... 2 Description... 3 Description... 3 Ordering numbers, 380-415
More informationSoftstarters Softstarters
, PSS & PST(B), PSS & PST(B) Low Voltage Products & Systems 6.1 General information PSR PSS From the moment the first electrical motors appeared, engineers have been searching for a way to avoid electrical
More informationABB n.v Power Quality in LV installations
ABB n.v. - 1 - Power Quality in LV installations PQ problems in LV installations 750 500 250 Volts 0-250 -500 Amps -750 3000 2000 1000 0-1000 -2000-3000 10:25:43.72 10:25:43.73 10:25:43.74 10:25:43.75
More informationProduct Flyer ELC ELECTRONIC LAMP CONTROL
Product Flyer ELC ELECTRONIC LAMP CONTROL ELC General Information The electronic lamp control units ELC are designed to power UV medium pressure discharge lamps. In different series we offer fully integrated
More informationChapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design
Dynamic power factor correction systems (real time PFC) Optimised, thermal design Long service life De-tuned version Minimised grid distortion Dynamic power factor correction systems (real time PFC) Hardly
More informationRELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES
RELIABLE SOLUTIONS in POWER ELECTRONICS RDAT SERIES Power Management Instruments BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES BATTERY CHARGER / DC RECTIFIER RDA / RDAT AUTOMATION
More informationEFFEKTA Power Supplies
EFFEKTA GENERAL INFORMATION UPS topology ON LINE - Double Conversion Classification VFI-SS-111 in accordance with IEC 62040-3 Nominal output power (Cos Ø 0,9) - kva 10 15 20 30 40 Nominal output power
More informationProduct information. ECOSS Electronic compact starter for wound rotor drives
Product information ECOSS Electronic compact starter for wound rotor drives Controlled and safe start-up of wound rotor drives Electronic compact starters are used when slip-ring motors have to be started
More informationAUTOMATIC CAPACITOR BANK WITH CONTACTOR OPERATIONS
AUTOMATIC CAPACITOR BANK WITH CONTACTOR OPERATIONS INSTRUCTION MANUAL (M98125401-03 / 03A) (c) CIRCUTOR S.A. ------Automatic capacitor bank with contactor operations ----- Page 2 TABLE OF CONTENTS 1. Introduction.
More informationGlossary/Technical appendix
Contents Power Supplies Overview.2 Standards and approvals.4 Glossary.6 1460790000 2014/2015.1 Power Supplies Overview Power Supplies Overview Power supplies are important links in the energy supply chain
More informationUltra Sine Inverter (US) Generation 4 (G4) User Guide
IBS Intelligent Battery System GmbH Seestrasse 24, CH-3600 Thun, Schweiz Tel: +41 33 221 06 16 Fax: +41 33 221 06 17 E-Mail: info@ibs-tech.ch Ultra Sine Inverter (US) Generation 4 (G4) User Guide IBS-USG4_en_v2.0.3.doc
More informationELECTRICAL TEST SOLUTIONS. Continuously variable control of voltage, current and power
ELECTRICAL TEST SOLUTIONS Continuously variable control of voltage, current and power As an internationally established brand in the area of test engineering systems we bear a special responsibility. Our
More informationPower Factor Correction
Power Factor Correction It's all about saving your money! Features that matter n Overcurrent up to 2.2 times rated current n Inrush current up to 300 times rated current n Self-healing type, segmented
More informationPower Electronics. MINISTOP Motor Brake Relay BA 9034N
Power Electronics IISTOP otor Brake Relay BA 9034 0256981 Your advantages Higher safety level and more economic by short stopping cycle Cost saving Compact design Easily appliance, no need for current
More informationTechnical data sheets
GE Consumer & Industrial Power Protection Technical data sheets Digital Energy Uninterruptible Power Supply LP 11 Series / 3 5 6 8 10 kva A product by: GE Consumer & Industrial SA General Electric Company
More informationAbstract. Benefits and challenges of a grid coupled wound rotor synchronous generator in a wind turbine application
Issue #WP102: Technical Information from Cummins Generator Technologies Benefits and challenges of a grid coupled wound rotor synchronous generator in a wind turbine application White Paper Ram Pillai
More informationADDITIONAL EMERGENCY POWER SUPPLY DEVICES
ADDITIONAL EMERGENCY POWER SUPPLY DEVICES ADDITIONAL EMERGENCY POWER SUPPLY DEVICES OP Emergency power supplies according to VDE 0107 ZSV installations according to VDE 0107 AREAS OF USE Hospitals Out-patient
More informationIndustrial PFC UPS System
Based on Statron s leading A.T.I.S. (Advanced Technology Industrial System) platform, the S3000 range is a true-industrial UPS system using the latest Power Factor Corrected (PFC) IGBT rectifier technology.
More informationDEVICE STATE/BYPASSED FAILURE OVERLOAD
Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated
More informationJ TS 7090 Thyristor power switch
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More informationPhase Modular Finally the benefits of Modular ups are for all
MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 The MUST 30/120 is an uninteruptible power supply, three phase input/ output, ranging from 15 kva to 120 kva
More informationELECTRIC TRACTION.
ELECTRIC TRACTION www.koncar.hr MODERNISATION ELECTRIC TRACTION VEHICLES Company KON AR - ELECTRIC VEHICLES Inc. upgrades electric locomotives, electric multiple unit and electric tramcars. Upgrading proceedings
More informationUser Guide 4Q kW D.C.Motor Regenerative Speed Controller. Part Number: Issue Number: 3
User Guide 4Q2 0.55-7.5kW D.C.Motor Regenerative Speed Controller Part Number: 0400-0042-03 Issue Number: 3 General Information The manufacturer accepts no liability for any consequences resulting from
More informationFilters for Converters and Power Electronics
Filters for Converters and Power Electronics Collection 2000 http://www.epcos.com EMC filters are indispensable in industrial installations when it comes to preventing RF disturbance in order to ensure
More informationValve monitoring system VDK 200 A S02
Valve monitoring system VDK 200 A S02 8.11 Printed in Germany Edition 11.17 Nr. 214 768 1 6 Technical description The VDK 200 A S02 is the compact valve monitoring system as per EN 1643 for automatic shut-off
More informationFor Operation in the Control Cabinet 3RW Soft Starters
General Data Overview The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of current peaks Avoidance of mains voltage fluctuations
More informationNEW. Heavy Duty Capacitors. Power Factor Correction Capacitors Type LKT. It s all about saving your money! Features that matter:
LKT Heavy Duty s NEW Overcurrent up to 2.7 times rated current Inrush current up to 450 times rated current Mean Life expectancy: 200,000 h. Up to 100,000 annual switching operations Features that matter:
More informationEDB6032_G/GB Antriebstechnik. Operating Instructions. Brake chopper 6032/6033/6034
EDB6032_G/GB 00376698 Antriebstechnik Operating Instructions Brake chopper 6032/6033/6034 These operating instructions are valid for the devices with the nameplate data: 6032_G.2E 6033_G.2E 6034_G.1A Type
More informationSINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options
/2 Overview /2 Benefits /2 Design /6 Function /8 Selection and ordering data /8 Options Technical data /1 General technical data /15 Control properties /15 Ambient conditions /16 Installation conditions
More informationHARMONIC FILTER REACTOR
380V 50Hz Series Resonance Frequency : 204Hz or p = 6% To be used with 415V capacitor only Design : According to VDE 0550/0532 & IEC 76 l 250 = 0.31 x l N Testing : Insulation strength tested at 2.5kV
More informationPower Electronics. POWERSWITCH Semiconductor Relay / - Contactor With Load Circuit Monitoring PH 9270
Power Electronics POWERSWITCH Semiconductor Relay / - Contactor With Load Circuit Monitoring PH 9270 0255163 Semiconductor relay PH 9270.91 Semiconductor contactor PH 9270.91/000/02 AC semiconductor relay
More informationPower Quality and Energy Management
Power Quality and Energy Management 1 2 Contents Power Quality...2 Power Factor Correction...4 Voltage Optimisation...8 Harmonic Filters and Reactors...12 1 Captech is Power Investigation and identification
More information1 Low-voltage Power-factor Correction capacitors KNK APPLICATION DESIGN
APPLICATION The KNK capacitors are used for power - factor correction of inductive consumers (transformers, electric motors, rectifiers) in industrial networks for voltages of up to 660 V. DESIGN Cylindrical
More informationMatrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL
Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference ❶ Performance Data Pages
More informationELG4125: Flexible AC Transmission Systems (FACTS)
ELG4125: Flexible AC Transmission Systems (FACTS) The philosophy of FACTS is to use power electronics for controlling power flow in a transmission network, thus allowing the transmission line to be loaded
More informationPresentation Soft starters 0 Altistart 48 soft start - soft stop units
Presentation Soft starters 5 6 7 65_Ver.-EN.fm/ Presentation (continued) Soft starters Applications The Altistart 8 soft start - soft stop unit is a controller with 6 thyristors which is used for the torque-controlled
More informationTECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)
TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power
More informationCHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM
106 CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM 5.1 INTRODUCTION Inherent characteristics of renewable energy resources cause technical issues not encountered with conventional thermal,
More informationsmartvar Dynamic VAR Compensator
smartvar Dynamic VAR Compensator DOES YOUR BUSINESS NEED TO SAVE MONEY? Discover a quick and easy way to identify cost saving opportunities. Improve the dynamic processes in your facility with smartvar.
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 150 200 250 300 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric
More informationThree Phase UPS Systems Range: 10 to 500kVA
Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Hitachi Hi-Rel Power Electronics Pvt. Ltd. is in the business of Industrial UPS Systems since 1987 and has rich experience in supplying
More informationVersion: 1.0 Mat.-Nr.: DBUS-WB50-80US
WINDY BOY 3000-US / 5000-US / 6000-US / 7000-US / 8000-US Addendum operating requirements Version: 1.0 Mat.-Nr.: DBUS-WB50-80US 1 Notes on this addendum 1.1 Validity This addendum does not replace the
More informationVFD Best Practices: Getting the Most from Your VFD Investment
TECH TOPICS VFD Best Practices: Getting the Most from Your VFD Investment The purpose of this document is to outline best practices for successful application and installation of VFDs. Following these
More informationStart-up instructions
E l e k t r o n i k s y s t e m e G m b H Development and production of electronical systems Eichelreuth 13 Phone: +49 8641 598360 83224 Grassau Fax: +49 8641 598364 E-Mail: info@rs-steiner.com Internet:
More informationUnit Protection System for Pumped-Storage Power Stations
Unit Protection System for Pumped-Storage Power Stations 1. Introduction In many power systems, pumped-storage power stations are used in addition to run-of-river power stations. These power stations serve
More informationPowerframes - Power Electronics
Powerframes - Power Electronics 70 series The study of power electronic devices, motor drives and circuits is an essential part of any course on power electrical systems. The Series 70 Power Electronics
More informationyears old German company involved in above mentioned two organizations for all Organization :- REO-GPD is supported by workforce of 15 workers.
Company Profile 2/202, LUNA ROAD, VILLAGE LUNA, TALUKA PADRA, DIST. VADODARA - 391440 GUJARAT, INDIA Phone No:- 02662-221723 0265-2396148 Fax:- 0265-2396971 E-Mail:- info@reogpd.com Web site:- www.reogpd.com
More informationTechnical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work
REC EPO STATUS BAT OUTPUT MUTE Critical Power Technical Data Sheet Uninterruptible Power Supply TLESM_UL_015-090_UPS front_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)
More informationLiebert Hipulse E The High-ECO-Availability UPS. AC Power Systems
Liebert Hipulse E The High-ECO-Availability UPS AC Power Systems We re Emerson Network Power, backed by Emerson, a global company that brings technology and engineering together to provide innovative solutions
More informationCooling Systems for Rolling Stock
Cooling Experts Around the Globe Cooling Systems for Rolling Stock Cooling tower for combined cooler for transformator oil and coolant DE DIESEL-ELECTRIC-LOCOMOTIVES AKG cooling towers installed in diesel
More informationKEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
KEOR HP THREE-PHASE from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Legrand SUPERIOR PERFORMANCE SERVICE CONTINUITY AND ENERGY EFFICIENCY Legrand, world leader
More informationGEPA. ARG-24 Series Battery Charger & Battery Group. User Guide
GEPA ARG-24 Series Battery Charger & Battery Group User Guide Contents 1. General... 1 2. Features... 2 3. Montage & Wiring... 3 3.1. Montage... 3 3.2. Wiring... 4 4. Usage... 5 4.1. Interface... 5 4.1.1.
More informationCOMBIVERT R6 MADE IN. Line Regen Systems Up to 1000 kva
R6 COMBIVERT R6 MADE IN GERMANY Line Regen Systems Up to 1000 kva KEB COMBIVERT R6 - Philosophy The kinetic energy of electric drives can be a valuable energy potential. Historically, that kinetic energy
More information315 kw 5000 kw, kv. ACS1000 Medium Voltage Drive The flexibility you require. The reliability you expect.
315 kw 5000 kw, 2.3 4.16 kv ACS1000 Medium Voltage Drive The flexibility you require. The reliability you expect. The ACS1000 industrial drive The ACS1000 medium voltage drive is part of ABB s industrial
More informationBurden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM
Contents Section Page 1.0 Introduction 1 2.0 Specification 1-4 3.0 Installation 5-8 4.0 Programming 9-10 5.0 Menus 10-12 6.0 Fault Finding/Diagnostics 12-13 7.0 Communication 13 8.0 Setting Up 13-16 1.0
More informationApplication Note. Dynamic PFC: Power Quality at the Docks (China State Shipbuilding Corporation)
Dynamic PFC: Power Quality at the Docks (China State Shipbuilding Corporation) P o w e r Q u a l i t y S o l u t i o n s www.epcos.com/pfc s The collection of PQS s is a library with in-depth information
More informationEMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)
LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTRES BM Plus Series BMLM 10-20 kva Single-phase BMLT 10-120 kva Three-phase CASH REGISTERS TELECOM- MUNICATIONS DEVICES E-BUSINESS (Servers Farms, ISP/ASP/POP)
More informationTECHNICAL DATA SHEET KVA UPS Systemss
Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800
More informationInstruction Manual. Harmonic Filter AHF 005/010. Drives Solutions
Harmonic Filter AHF 005/010 Instruction Manual Drives Solutions Contents Safety... 2 Warnings... 2 Symbols used in this manual... 2 Operator s safety... 2 Avoid filter module damage... 2 DC-link resonance...
More informationHIGH POWER SOLENOID DRIVER 1
Elactis SA Switzerland Phone : Fax : E-mail : Web : +41 22 364 65 85 +41 22 364 65 87 info@elactis.com http://www.elactis.com HIGH POWER SOLENOID DRIVER 1 ADRV1012K 1 This datasheet is a preliminary description.
More informationSoliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids
Technical Information Soliphant T FTM260 Level limit switch Cost-effective vibration limit switch for fine-grained solids Application Soliphant is a rugged level limit switch for use in silos containing
More informationMAHA Two Post Lifts. Model: ECON III 3.0 ECON III 3.5 ECON III 4.0 ECON III 5.0 HL III 4.0 HL III 5.0. Lifting Technology
Wir im Allgäu. MAHA Two Post Lifts Model: ECON III 3.0 ECON III 3.5 ECON III 4.0 ECON III 5.0 HL III 4.0 HL III 5.0 Lifting Technology DIN EN ISO 9001:2008 ISO 14001:2004 SINCE 1969 For passenger cars
More informationKEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
KEOR HP THREE-PHASE from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Legrand SUPERIOR PERFORMANCE SERVICE CONTINUITY AND ENERGY EFFICIENCY Legrand, world leader
More informationPower Factor Correction
Power Factor Correction Power Factor Correction and Voltage Optimisation have been around since the turn of the 20 th century and although in many cases their individual benefits and attributes make them
More informationProtective firing in LCC HVDC: Purposes and present principles. Settings and behaviour. V. F. LESCALE* P. KARLSSON
21, rue d Artois, F-75008 PARIS B4-70 CIGRE 2016 http : //www.cigre.org Protective firing in LCC HVDC: Purposes and present principles. Settings and behaviour. V. F. LESCALE* P. KARLSSON VILES Consulting
More informationStart-up instructions
E l e k t r o n i k s y s t e m e G m b H Development and production of electronical systems Eichelreuth 13 Phone: +49 8641 598360 83224 Grassau Fax: +49 8641 598364 E-Mail: info@rs-steiner.com Internet:
More informationElectronic Circuit Breaker ESS20
Electronic Circuit Breaker ESS20 Description Electronic circuit breaker type ESS20 is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 24 V switch-mode
More informationShunt Capacitor Bank Protection in UHV Pilot Project. Qing Tian
Shunt Capacitor Bank Protection in UHV Pilot Project Qing Tian 2012-5 INTRODUCTION State Grid Corp. of China, the largest electric power provider in the country, has first build a 1000 kv transmission
More informationTechnical Data Sheets
GE Consumer & Industrial Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 160 200 250 300 kva PurePulse TM 400 Vac CE Series 1 Date of issue: 15.02.2007 SGSE160-200S1UPS01
More informationPOWER kva
+44 (0)20 8868 3732 TECHNICAL DATA SHEET B9600 400-800kVA GENERAL INFORMATION UPS Type ON LINE - Doppia Conversione Nominal output power (Cos φ0,8) kva 400 500 600 800 Nominal output power (Cos φ1,0) kw
More informationEMPAC Metal enclosed capacitor bank for wind applications
EMPAC Metal enclosed capacitor bank for wind applications Introduction The EMPAC is a Metal Enclosed Capacitor Bank suitable for voltages between 1 kv and 36 kv for reactive compensation in MV networks
More informationCompact Energy Storage Module. Modular Systems, EPDS. Product overview
Compact Energy Storage Module Modular Systems, EPDS Product overview ABB Power Products in energy storage Portfolio coverage Stationary Application Focus ESM Load leveling Spinning reserve ESM Behind-the-meter
More informationRLW. Reactors. mtecorp.com. Smaller, lighter protection. Power quality. Solved.
mtecorp.com RLW Reactors State-of the-art solution for absorbing everyday power line disturbances Smaller, lighter protection. Proven performance in the field Reliable and economical Compact and lightweight
More informationPower Conversion Systems 2005/2006. Schaefer the Power to make it happen.
Power Conversion Systems 2005/2006 Schaefer the Power to make it happen. Company profile workforce experience customer orientation flexibility reliability Schaefer Elektronik, founded in 1969, has grown
More informationgimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy
GE Digital Energy Technical data sheet Uninterruptible Power Supply LP11 924 Series 6 & 10 kva gimagination at work GE T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www..com General data Topology VFI,
More informationDRAFT. Guidelines on Power quality & safety issues in usage of roof-top solar pv system CENTRAL ELECTRICITY AUTHORITY
DRAFT Guidelines on Power quality & safety issues in usage of roof-top solar pv system CENTRAL ELECTRICITY AUTHORITY 2018 1. INTRODUCTION Solar energy has become the most popular renewable energy source
More informationLINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)
LINEAR LED DRIVERS ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL) 186443, 186444, 186486, 186487, 186488, 186491, 186492, 186737 Typical Applications Built-in in linear luminaires for Office lighting
More informationTechnical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work
Technical Data Sheet Uninterruptible Power Supply TLESM_030-180_UPS front_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91
More informationDevelopment of Small-capacity OFF-LINE UPS
1 / 5 SANYO DENKI TECHNICAL REPORT No.9 May-2000 Features: Technical Developments in 1999 Development of Small-capacity OFF-LINE UPS Chiaki Seki Hideaki Yoda Hideaki Matsuo Shigeo Ichikawa 1. Introduction
More informationPower Factor Correction Capacitors Type LKT
Power Factor Correction s LKT E337088 Features that matter: Handles continuous current up to 2.25 / 2.7 times rated current Withstands inrush current up to 375 / 450 times rated current Environment-friendly,
More informationTELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)
Local Area Networks (LAN) ServerS DATA CENTRES CASH REGISTERS TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)
More informationcomponenti elettronici electronic components FILTERS - CHOKES
www.comsel.it componenti elettronici electronic components FILTERS - CHOKES join us! IEC INLET FILTERS / POWER ENTRY MODULES 0012727 FN 281-2-06 SINGLE-PHASE P.E.M FILTER WITH FUSE AND SWITCH 2A* 40 0011891
More informationVLT Soft Starter. Remote operation. Serial communication 24 V AC/DC V AC. Constant effort to improve MCD 100, MCD 201, MCD 202, MCD 3000
.5 00 (mm)hxwxd (Amps) 0x,5x, CSA, A: :0 (AC5b) 5A: 8:0000 0xx8 5A: 65:0080 0xx8 0 T C V Remote operation Series + protection Remote operation of 0, 0 and 00 is facilitated by the dedicated remote operator
More informationTELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)
LOCAL Area Networks (LAN) ServerS DATA CENTRES CASH REGISTERS TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)
More information