amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT
|
|
- Ferdinand Hawkins
- 5 years ago
- Views:
Transcription
1 amp ramp Operators Manual Saftronics S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD 6QT Tel: Fax: Website: sales@saftronics.co.uk Issue April 00 Page
2 Page Page Amp Ramp Specification Mains Voltage 380/45V Mains Frequency Control Voltage Parameter Adjustment 50/60Hz Not required Pedestal Current % I Ramp Up Time seconds Current Limit % I LED Indication Red Ready Yellow Ramping Orange Current Limit Green Full Speed Red Flashing Drive rating exceeded Relay Outputs Overload Ratings Starts per Hour Top of Ramp - N/O Volt Free Contact A/00VA AC (0-40V) Run-N/O Volt Free Contact A/50VA AC (0-40V) 00% Continuous Current 300% Current for 30 seconds 600% Current for 6 seconds 0 per hour evenly spaced, more possible by derating. CE Marking CE marked to generic standards in accordance with BS EN using capacitive filter internally fitted. Heat Loss 4.5 Watts per Amp Cooling Naturally cooled heatsink up to kw, fan cooled 30kW and above. Fan voltage 40V. All heatsinks mounted vertically, allowing 50mm around unit for cooling. Available Sizes 0SA-5 5kW Amp Ramp 30A rated 0SA- kw Amp Ramp 45A rated 0SA-30 30kW Amp Ramp 60A rated 0SA-37 37kW Amp Ramp 75A rated 0SA-45 45kW Amp Ramp 85A rated 0SA-63 63kW Amp Ramp 0A rated 0SA-75 75kW Amp Ramp 45A rated 0SA-90 90kW Amp Ramp 70A rated 0SA-0 0kW Amp Ramp 05A rated High Speed Fuses Recommended for thyristor protection. See Page 6 for more details
3 Amp Ramp Dimension Details Amp Ramp Connections 5kW/kW AMP RAMP 5kW DEPTH - 35mm MTG HOLE - Ø6.6 WEIGHT - 5Kg SW 5kW AMP RAMP kw DEPTH - 70mm MTG HOLE - Ø6.6 WEIGHT - 8Kg SW L L L3 U V W L L L3 MAINS SUPPLY 30-63KW AMP RAMP U V W MOTOR SUPPLY DEPTH - 70mm MTG HOLE - Ø6.6 WEIGHT - 9Kg START CONTACT NOT USED CT INTERNALLY CONNECTED RUN CONTACT OUTPUT NOT USED TOP OF RAMP CONTACT OUTPUT SW - 0KW AMP RAMP 75-0KW AMP RAMP 38 DEPTH - 95mm MTG HOLE - Ø6.6 WEIGHT - 7Kg L L L3 U V W L L L3 MAINS SUPPLY U V W MOTOR SUPPLY Page START CONTACT NOT USED CT INTERNALLY CONNECTED RUN CONTACT OUTPUT NOT USED TOP OF RAMP CONTACT OUTPUT
4 Fitting & Operating Instructions - Ensure unit is mounted vertically in a suitable dry, dust and vibration free enclosure, with connection terminals at the bottom. - Electrical connections must be made as shown on drawings. Phase rotation must be correct ie: L, L, L3 = R, Y, B. PLEASE NOTE IF PHASE ROTATION IS NOT CORRECT READY LED WILL NOT LIGHT AND UNIT WILL TRIP. - The unit should be used in conjunction with a suitably rated thermal overload to protect the motor and semiconductor fuses, to protect the thyristors. Setting Up Switches Please note, on Amp Ramp there are two switches that are relevant, and must be set by the user. SW: Fitted to 5kW Amp Ramp to select the motor kw SW: Fitted to Amp Ramps to set stop delay and re-start delay SW: Firstly the current feedback must be scaled by setting the selection switches placed above the terminals. The following table gives the switch settings for standard motor ratings. Please note this is only necessary on 5kW model, all other models are factory scaled for correct feedback. SW- Stop Delay If the soft starter is to be used with a by-pass contactor, SW- should be set to the on position. This will reduce contact burning by allowing the soft starter to break the current instead of the by-pass contactor. SW- Re-start Delay This function prevents re-starting of the motor for a period of approximately 0 seconds. This is particularly desirable in the case of high interia loads where the motor may continue to rotate at speed after the power is removed. If a quick re-start is required, for example, in the case of a dual speed motor, the function may be disabled by setting SW- to the on position. Setting Up - Potentionmeters Initial adjustments: Pedestal - Minimum Current Limit - Maximum Ramp Time - Maximum Start the drive and increase the pedestal until the motor just starts to turn, i.e. sufficient torque is present to just overcome the stiction. It may be neccesary to start/stop the unit a few times to ensure the optimum setting. Then reduce the ramp time to give the desired start period. With high interia loads it may be neccesary to limit the current using current limit adjustment. The time taken to reach full speed will then be affected by the current limit setting. Switch Number kw Rating = Up = Down Page Page 3
5 Typical Circuit Amp Ramp - No By-Pass C C Typical Circuit Amp Ramp - with By-Pass C C C Page 4
6 Page Page 5 Emc and Amp Ramp In order to achieve compliance with generic EMC standards in accordance with BS EN , it is necessary to fit capacitive filter. On kw Amp Ramp and above, an internal filter is fitted in order to be compliant with the standards. An internal filter can be fitted to 0SA-5 upon request. Important Information:. When power factor correction capacitors are used, they must be connected on the supply side of the soft start and energised when the motor has reached full speed.. For applications where forward and reverse operation is required, the contactors MUST be wired in the output of the Amp Ramp as the units are phase sensitive 3. Amp Ramp 5kW and above are fitted with Top of Ramp for energising by-pass contactors. Circuit Diagram for this is shown on page Please note, if changing a control card on Amp Ramp, the units are fitted with burden resistors to ensure correct feedback from internal CT s. Please ensure correct burden resistors are fitted to new control card. Fuses for Amp/Ramp High speed fuses are recommanded for protection of thyristors and these are available in sets of three, supplied with fixings. The recommended fuse sizes are shown in the table below: Fuses are supplied with the following fixing types: DIN size 0000 body 80A-00A DIN size 000 body 60A-35A DIN size 00 body 400A Dimensions and fuse holder details are shown on page 6. Soft Start Type Fuse Product Code Current Rating 0SA-5 70M06 80A 0SA- 70M07 00A 0SA-30 70M39 60A 0SA-37 70M30 00A 0SA-45 70M30 00A 0SA-63 70M3 50A 0SA-75 70M3 35A 0SA-90 70M6 400A 0SA-0 70M6 400A
7 Fuse Dimensions 80 0 Page AMP FUSE AMP FUSE
8 Saftronics EMC Tests Product: Amp Ramp 0SA Range Filters: Internal capacitive filter at 5kW and above EMC Immunity Tests. Electrostatic discharge test - IEC 80- Test level 4kV. Radio frequency electromagnetic field - ENV 5040 Test Level 0V/M 80% amplitude modulated at khz 3. Fast transients tests - IEC 80-4 Test level kv EMC Emissions Tests. Compliance with radiated and conducted emissions to EN5008- (class A) Please refer to graph of results All tests are conducted in accordance with BS EN Please refer to EMC Guide for installation guidelines dbuv DP AV MHz Page Page 7
9 Issue Numbers Issue Description/Modification Date Modified Checked Initial issue March 00 - AD All pages - Reference to 4kW Amp Ramp Removed /4/0 AD SM Page 8
DEVICE STATE/BYPASSED FAILURE OVERLOAD
Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated
More informationBurden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM
Contents Section Page 1.0 Introduction 1 2.0 Specification 1-4 3.0 Installation 5-8 4.0 Programming 9-10 5.0 Menus 10-12 6.0 Fault Finding/Diagnostics 12-13 7.0 Communication 13 8.0 Setting Up 13-16 1.0
More informationMCD 200 Series Soft Starters
MCD 200 Series Soft Starters AC motors often cause one or more serious problems during startup acceleration. MCD 200 Series electronic soft starters control motor current to provide a smooth start. When
More informationRE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW
Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient
More informationDimensions WxHxD [mm] Weight [kg]
SPECIFICATIONS The SOLSTART electronic soft starter incorporates two sets of thyristors (Two phase control) to start a threephase squirrel cage induction motor and an internal bypass. By supplying a slowly
More informationTechnical specifications
Technical specifications Type 3RW30 03 3RW3-1B0 3RW3-1B1 Control electronics Rated control supply voltage V 24 230 CDC 24 CDC (+10 %-15 %) 110 230 CDC (+10 %-15 %) Rated control supply Without fanwith
More informationRE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW
Page 1 of 5 RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & Features: Benefits: 0-10Vdc or 0-5Vdc control input Over temperature protection with auto reset Din-rail mounting Efficient electronic switching No
More informationRVS-DN Digital Reduced Voltage Motor Starter
RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3
More information1.1 Caution Statements
USER MANUAL 1.1 Caution Statements Caution Statements cannot cover every potential cause of equipment damage but can highlight common causes of damage. It is the installer's responsibility to read and
More informationwww.ic-electronic.com Soft starter with integrated Motor Protection, Current and Voltage control Single phase controlled with internal by-pass ated operational Voltage 230VAC Frequency 45... 65Hz Self
More informationACCESS Always replace the cover panel on the unit after gaining access to the electrical connections.
F A I R F O R D E L E C T R O N I C S Soft Starters and Energy Optimising Soft Starters Guide to contents - applicable to Basic Guide to the Installation and Operation Of the Soft Starter 5MC software
More informationSOLSTART Instruction Manual
Solstart Analog Soft Starter 8-58A, 220-600V Instruction Manual Ver. 23/03/2009 2 Table of Content SOLSTART Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3
More informationHIB Enclosed Inverter User Guide
HIB Enclosed Inverter User Guide (0.75kW~22kW) V1.2.0 Contents 1 Safety information...1 2 Technical Data...2 3 Motor Connection...4 4 Operation...5 5 Single phase circuit diagram...7 6 Three phase circuit
More informationRVS-AX Instruction Manual
RVS-AX Analog Soft Starter 8-170A, 220-600V Instruction Manual Ver. 10/11/2009 2 Table of Content RVS-AX Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3
More informationSoft Starters and Energy Optimising Soft Starters Guide to contents - applicable to
Soft Starters and Energy Optimising Soft Starters Guide to contents - applicable to 5MC software V56 Basic Guide to the Installation and Operation Of the Soft Starter 1 Mechanical Outlines Referring to
More informationGuide to contents - applicable to
FAIRFORD ELECTRONICS Basic Guide to the Installation and Operation Of the QFE Soft Starter Guide to contents - applicable to 5MC software V55 Mechanical Outlines Referring to the appropriate size of QFE,
More informationSolid State Relays, 3-phase
PMA Prozeß- und Maschinen-Automation GmbH Solid State Relays, 3-phase Zero-Point switching, heatsink integrated Main Characteristics: Three-phase controlled Zero switching LED display Various connection
More informationFor Operation in the Control Cabinet
As an option the thyristors can also be protected by SITOR semiconductor fuses from short-circuiting so that the soft starter is still functional after a short-circuit (type of coordination ). Three LEDs
More informationSoft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP
Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD Soft starting of 3-phase scroll compressors up to 95Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE704 AUTOSTART CONTROL MODULE OPERATING MANUAL 057-042 704 Operating Instructions Issue 2.1 18/06/2007 11:27:00 JR - 1 - Deep Sea Electronics Plc
More informationRVS-DX Digital Reduced Voltage Motor Starter
RVS-DX Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3
More informationDIN EN UL 508 / CSA 3RF A A 0 2
PMA Prozeß- und Maschinen-Automation GmbH Solid State Relays Zero-Point Switching, heatsink integrated Main Characteristics: Zero switching LED display Various connection technologies Plug-in control terminal
More informationSOLID STATE POWER CONTROLLERS ACL-series AC1-series AC3-series ACF3-series DAC3- series
H & C SOLID STATE POWER CONTROLLERS ACL-series AC1-series AC3-series ACF3-series DAC3- series OPERATION This power controller is designed to regulate a resistive load by switching the load on and off in
More informationSiemens AG RW BB14 3RW BB14 3RW BB14. per PU three-phase induction opera- Rated Rated power of three-phase
Siemens AG 2008 3RW Soft Starters Selection and ordering data 28-1BB14 38-1BB14 47-1BB14 Ambient temperature 40 C Ambient temperature 50 C Size DT Order No. Price Rated Rated power of Rated Rated power
More informationTime scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)
86 Timer modules 86 Timer modules for use in conjunction with relay & socket. 86.00T - Multi-function & multi-voltage timer module 86.30T - Bi-function & multi-voltage timer module Complies with EN 45545-2:2013
More informationTime scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets
86 Series - Timer modules Features 86.00 86.30 Timer modules for use in conjunction with relay & socket. 86.00 - Multi-function & multi-voltage timer module 86.30 - Bi-function & multi-voltage timer module
More informationPresentation Soft starters 0 Altistart 48 soft start - soft stop units
Presentation Soft starters 5 6 7 65_Ver.-EN.fm/ Presentation (continued) Soft starters Applications The Altistart 8 soft start - soft stop unit is a controller with 6 thyristors which is used for the torque-controlled
More informationControl Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD
Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control
More information3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2008
General data Overview The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of current peaks Avoidance of mains voltage fluctuations
More informationRE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC
Characteristics time delay relay 2 functions - 0.02 s..300 h - 24..240 V AC - 2 OC Complementary Product front plate size Control type Housing material Main Range of product Product or component type Electrical
More information(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2
Solid-state Contactor (New Heat Sink Construction) G3PB Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications.
More informationMAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive
MAKING MODERN LIVING POSSIBLE Design Guide VLT MCD 100 Soft Starter the single speed drive Contents Contents 1.1.1 Introduction 2 1.2 Technical Data 3 1.3.1 Functional Diagram 4 1.3.4 Wiring 5 1.3.5 Adjustments
More informationData sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443
CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O December 2002 DKACT.PD.C50.G2.02 520B1443 2 DKACT.PD.C50.G2.02 Danfoss A/S 12-2002 Introduction The MCI soft starters
More information& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL
72-6850 & 72-6852 HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 2 Safety 4 EMC 5 Installation 6 Connections 6 Operation 7 Maintenance and Repair 8 www.tenma.com
More informationThe Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC
The Z Series Zero-Fired SCR Power Controllers 60-1200 AMPS 120-600 VAC SCR Power controllers for resistance heating applications. ROBICON 1996 Rev. 7/96 Applications Robicon s Z series power controls are
More informationDesign Guide. VLT Soft Start Controller MCD 100
Design Guide VLT Soft Start Controller MCD 100 Introduction The MCD 100 soft starters are designed for soft starting and stopping of 3 phase a.c. motors, thus reducing the inrush current and eliminating
More informationLV Capacitor CLMD03 Power Module Instruction manual
LV Capacitor CLMD03 Power Module Instruction manual Table of Contents 1 Safety... 3 2 Upon reception... 3 2.1 Inspection on reception... 3 2.2 Storage- transportation handling... 3 3 Hardware Description...
More informationFeatures. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter
Features TRIAC Dimmable LED Driver Triac dimmable with leading or trailing edge dimmers Class II with SELV output (no earth required) Extra-large screw terminals and integrated cable clamps for easy installation
More information3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2006
General data Overview The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of current peaks Avoidance of mains voltage fluctuations
More informationDUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL
72-7570 DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL Table of Contents Specification 1 Safety 3 EMC 4 Installation 5 Connections 5 Operation 6 Maintenance 8 Specification General specifications
More informationFor Operation in the Control Cabinet
For Operation in the Cabinet 3RW30 for standard applications Overview The SIRIUS 3RW30 soft starters reduce the motor voltage through variable phase control and increase it in ramp-like mode from a selectable
More informationStarting Torque Limiter Type TCI (Soft Start)
Data sheet Starting Torque Limiter Type TCI (Soft Start) Starting Torque Limiters are designed for the soft starting of single and tree phase AC motors. The controller allows smooth starting of all AC
More information150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz
Catalog Number Explanation Open Controllers a Bulletin Number Solid-State Controller B H H B B B B B B B B B B B B B Solid-State Controller and Isolation Contactor (enclosed only) b Controller Ratings
More informationModel Number Structure
Solid State Relays (Single-phase) G3PB New Single-phase Solid State Relays with Compact Size for Heater Control Slim models with a thickness of only 22.5 mm are also available. Compact design achieved
More informationATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)
Product datasheet Characteristics ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/400...440V(45kW) Complementary Assembly style Function available Supply voltage limits Main Range of product
More information1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF
Features Switching Regulator Description Efficiency up tpo 94%, no need for heatsinks Pin-out compatible with LM78XX linears Low profile (L/W/H=11.5 x 7.5 x 1.2mm) Wide input range Short circuit protection,
More informationEPS/ELA-Series User Manual EPS/ELA 250W
EPS/ELA-Series User Manual EPS/ELA 250W EPS Stromversorgung GmbH Tel: +49 (0)821 570451 0 Index 3 Page: 1 Table of contents: Page 1. Features of ELA-Series... 3 1.1 Basic Functions... 3 1.2 Options...
More informationBE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!
INSTALLATION INSTRUCTIONS FOR SYMCOM S MOTORSAVER MODEL 460 BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!
More informationAltistart 48 Y-Range Soft Start Controllers Installation Guide
Altistart 48 Y-Range Soft Start Controllers Installation Guide Instruction Bulletin 30072-450-61B Retain for future use. For Use in North America 30072-450-61B Altistart 48 Y-Range Soft Start Controllers
More informationPower Electronics. Motor brake relay GA 9031 ministop
Power Electronics Motor brake relay GA 90 ministop 0 Thyristor electronic brake relay for motors up to kw Adjustable braking current up to 0 A Adjustable braking time Automatic standstill monitoring (optional)
More informationINDUSTRIAL POWER SUPPLIES SFL-SERIES
INDUSTRIAL POWER SUPPLIES SFL-SERIES Operating Instructions 1. Application The SFL-series are compact, rugged switching power supplies designed for applications in process automation and other industrial
More informationTHE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter
THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS MCD 3000 Soft starter THE PERFECT SOFTENER OF ROUGH STARTS The MCD Soft starter ranging from 7.5 to 800 kw is the optimum solution to a range of
More informationCI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O
Data sheet CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O The MCI soft starters are designed for soft starting and stopping of 3 phase AC motors, thus
More informationSOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B
Solid State Relays SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B AC semiconductor contactor Zero switching (RJ1A) or instant-on switching (RJ1B) Direct copper bonding (DCB) technology LED-indication
More informationINSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY
CONNECTIONS INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION!! FOLLOW NATIONAL, STATE AND LOCAL CODES! READ THESE INSTRUCTIONS
More informationSoftstarters. Softstarters Type SSM Medium voltage ,800V 1
Medium voltage 2300 13,800V 1 Description Fused disconnect switch with blown fuse indicators and door safety interlocks rated for load break/fault make with automatic grounding arm Inline isolation vacuum
More informationSynergy EN product information
Synergy EN60947-4-2 product information Rated operational voltages U e 200Vac to 480Vac Rated operational currents I e See Rating Table Rating index See Sizing Guide Rated frequency/frequencies 50-60Hz
More informationBeaver Power Factor Correction Capacitors
Beaver Power Factor Correction Capacitors Beaver Low Voltage Power Factor Correction Capacitors are designed for long life and are made with the highest quality materials. All units are assembled in Canada
More informationApplication example of a motor controlled by MCD100 and protected by a circuit breaker
VLT T Soft Start Controller MCD 100 MCD 100 is a cost effective and extremely compact soft starter for AC motors up to 11 kw. Due to a unique semiconductor design MCD 100 is a true fit and forget product.
More information2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4
CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power
More informationLow voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog
Low voltage AC drives ABB micro drives ACS55 0.25 to 3 hp/0.18 to 2.2 kw Catalog ACS55 IP20 Overview ACS55 micro drives are designed for use in a wide variety of simple machinery applications where only
More informationSoftstarter Intelligent Controllers
Softstarter Intelligent Controllers Series Modes of Operation (Standard) Soft Start 100% Percent Voltage Initial Torque Start Run This method has the most general application. The motor is raised from
More informationSolid State Relays contactor with Integrated Fuse Type RGC1F
Solid State Relays contactor with Integrated Fuse Type RGC1F Solid State Contactor with integrated fuse Zero Cross Switching Operational voltage: 230 VAC and 600 VAC 35mm width Control voltage: 4-32 VDC
More informationObserve all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.
Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary
More informationASTAT XB USER MANUAL. 1 Caution Statements
ASTAT XB USER MANUAL 1 Caution Statements Caution Statements cannot cover every potential cause of equipment damage but can highlight common causes of damage. It is the installer's responsibility to read
More informationRE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC
Characteristics time delay relay 2 functions - 0.02 s..300 h - 24..240 V AC - 2 OC Main Range of product Product or component type Electrical connection Discrete output type Contacts type and composition
More informationLA Motor Protection. A South African Company to be Proud of
LA Motor Protection Relay Physical Address: 298 Soutter Street, Pretoria West Tel: 083 454 6949, +27 12 327 1729 Fax: +27 (0)12 327 1733 Toll Assist: 0860 10 30 41 www.newelec.co.za sales@newelec.co.za
More informationInnovation in soft start technology HFE-2 USER MANUAL. MAN-HFE-002. Version 01
Innovation in soft start technology HFE-2 USER MANUAL MAN-HFE-002. Version 01 HFE-2 user guide Fairford Electronics Ltd Bristow House Gillard Way, Ivybridge PL21 9GG UK www.fairford.com 2016 by Fairford
More informationModel 340i / 680i / 1220i DC drive product manual HG iss 8 1
Model 340i / 680i / 1220i DC drive product manual HG102938 iss 8 1 Sprint Electric Limited, Arundel, UK Tel. +44 (0)1903 730000 Fax. +44 (0)1903 730893 Email. info@sprint-electric.com www.sprint-electric.com
More informationDEEP SEA ELECTRONICS PLC
DEEP SEA ELECTRONICS PLC 703 AUTOMATIC START MODULE OPERATING INSTRUCTIONS Author:- John Ruddock 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 1 - >
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE710 AUTOSTART CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44
More informationMODVAR Low voltage reactive power compensation modules Installation manual
MODVAR Low voltage reactive power compensation modules Installation manual MODVAR Low voltage reactive power compensation modules Before installation, read this manual carefully and keep at the disposal
More informationOpen Frame Power Supplies
, 0 300 Watt Features Small and compact PCB Construction Optional with Chassis and Cover Universal Input 8 264 VAC, Output Voltage adjustable Compliance to E 6000-3-2 (PFC) EMI meets E022, Class B and
More informationHp V AC Current Rating [A] 230V AC 60 Hz
Product Selection/Options Open Type Controllers Up to V AC kw Hp V AC Current Rating [A] V AC Hz V AC Hz V AC Hz V AC Hz V AC Hz / Hz Control V AC/DC Control.. -BNBD -BNBR. -BNBD -BNBR -BNBD -BNBR -BNBD
More informationVariable speed application guidelines
Variable speed application guidelines Frequency converter VLT 00 SCROLL COMPRESSORS REFRIGERATION AND AIR CONDITIONING www.danfoss.com Introduction The introduction of speed control for refrigeration
More informationNote1: tested at nominal Vin, full load and at +25 C ambient. Package (3) CTRL Logic (2)
Features Regulated Converters : Wide input voltage range.6kvdc Isolation UL, IEC/EN69 and EN certified Efficiency up to 88% OVP, OCP & OTP + C max. case temperature Description The RPA-AW series are high
More information300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds
Digital Soft Start Controls 9 thru 900 Amps 208-460V 50/60 Hz. 9 thru 900 Amps 208-575V 50/60 Hz. Applications: Controlled ramp start and stop, minimize spillage in material handling, reduced water hammer
More informationOutput Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %
Doc. EC-0093 FEATURES Industrial Standard 2"x1" Package Ultra-wide Input Range 9-36VDC, 18-75VDC, 40-160VDC I/O Isolation 3000VAC with Reinforced Insulation Operating Ambient Temp. Range -40 C to +88 C
More informationVLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000
VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000 Soft starts Protect Gear, Goods, Equipment and Environment An AC motor switched directly on to the mains power supply will struggle to reach its nominal
More informationPower Supplies. SDN-C Compact DIN Rail Series
SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high effi ciency and compact size with new visual diagnostic LEDs
More informationCI-tronic Soft Start Motor Controller Type MCI 25B with Brake
Data sheet CI-tronic Soft Start Motor Controller Type MCI 25B with Brake MCI 25B motor controller with brake is designed for soft starting and braking of 3 phase AC motors. The digital controlled soft
More informationOperating Instructions. Drives Solutions.
Decentral Motor Starter DMS 300 Operating Instructions Drives Solutions www.danfoss.com/drives Contents Introduction... 3 Operating instructions... 3 Symbols used in this manual... 3 General warning...
More informationSolid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60
Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60 Zero switching (RM1A) or instant-on switching (RM1B) AC Solid State Relay Direct copper bonding
More information201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010
INSTALLATION INSTRUCTIONS Revision A1 Rapid City, SD, USA, 01/2010 MODELS 201A 201A-9 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848 (605) 348-5580 fax (605) 348-5685 BE SURE POWER
More informationPower Supplies. POWER SUPPLIES AC to 24VDC Regulated Primary Switching. TRANSIENT VOLTAGE SUPPRESSORS Industrial Design MINI UNIVERSAL MOUNT
Power Supplies AC to DC AC to 24VDC Regulated Primary Switching SINGLE PHASE 115 / 230 VAC 24VDC 5 VDC 12VDC 10 AMP TO 20 AMP THREE PHASE 480 VAC 24VDC 10 AMP TO 50 AMP! DIN RAIL MOUNT! COMPACT DESIGN
More informationOutput Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %
FEATURES Industrial Standard Quarter Brick Package Wide Input Range 43-101VDC & 66-1VDC Excellent Efficiency up to 92% I/O Isolation 3000VAC with Reinforced Insulation Operating Ambient Temp. Range - C
More informationPressure transmitter JUMO dtrans p02
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 e-mail: mail@jumo.net Internet: www.jumo.net JUMO
More informationDC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES
DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE FEATURES 4:1 Ultra Wide Input Range Output Current up to 2000 ma Miniature SIP (Single-In-Line) Package, 0.86 0.36
More informationDC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES
DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS FEATURES 2:1 Wide Input Voltage Range: 4.5-12 Input, 9-18 and 18-36 and 36-75 5000Vac Input to Output 2MOPP Isolation Remote On/Off
More informationUser Guide. Digistart CS. 7.5kW - 110kW (18A - 200A) 200V, 400V, 575V
User Guide Digistart CS 7.5kW - 110kW (18A - 200A) 200V, 400V, 575V 0477-0000-04 www.controltechniques.com General The manufacturer accepts no liability for any consequences resulting from inappropriate,
More informationBR Second Position Voltages. AA Fourth Position
1336S First Position Bulletin Number BR Second Position Voltage Letter AQ BR CW A B BP BX C Q R RX W Voltages 200-240V AC or 3V DC 380-480VAC or 513-620V DC 500-600V AC or 775V DC or 200-240V AC 380-480V
More informationLoad (2) Single or Dual
Features Regulated Converter Reinforced insulation for 25VAC working voltage Clearance and creepage distance >8.mm 5kVAC I/P to O/P 2MOPP isolation 2µA patient leakage current Industry standard pinout
More informationSingle & Three-Phase Soft Starters
Submittal Data English Language/IP Units 11/13 Contact Information: Hyper Engineering, Pty. Ltd. 9000 Conservation Way Fort Wayne, IN 46809 www.hypereng.com sales@hypereng.com (877) 304-0724 Model Nomenclature
More informationThe Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller
The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller A pre-engineered solution with an integrated circuit breaker disconnect and an Altistart 22 soft start in a stand-alone enclosure Make the
More informationIndustrial Power Supplies
, Features Switch Mode Power Supplies for DIN-rail Mounting 6 Power Ranges with 2, 3, 6, 12, 20 and 24 A Current (24 VDC Models) Selectable 115/ 230 VAC Input Very low Ripple and Noise EMI complies with
More informationLow voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog
Low voltage AC drives ABB component drives ACS55 0.18 to 2.2 kw / 0.25 to 3 hp Catalog ABB component drives ABB component drives ABB component drives are designed to be incorporated into a wide variety
More informationHigh reliability against cyclic and peak current loads / age resistant due to high motor start up currents
HHM High Voltage Fuses Motor Circuit Protection DIN and British Standard SIBA Motor Rated Fuses are available in - German DIN Standard and - British Standard Design The large variety in body sizes / mounting
More informationUSERS MANUAL MCD REMOTE OPERATOR
USERS MANUAL MCD REMOTE OPERATOR Order Code: 175G9004, 175G3061 Contents Contents Introduction...2 Important User Information...2 General Description...2 Symbols Used in this Manual...2 Installation...3
More informationALTIVAR 58 AC Drives
Class 8806 / 8839 / 8998 CONTENTS Schneider Electric Brands Page ALTIVAR 58 AC Drives............................................... 3 Drives Overview...................................................
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More information