PRS 9. Installation Instructions Cycling Timer PRS 9. A Siebe Group Product 1

Size: px
Start display at page:

Download "PRS 9. Installation Instructions Cycling Timer PRS 9. A Siebe Group Product 1"

Transcription

1 PRS 9 Installation Instructions Cycling Timer PRS 9 A Siebe Group Product 1

2 Dimensions / Parts Drawings (6TE) Fig. 1 A B C D E I H G J F MAX 70 C Fig. 2 MAX 95 % 2

3 Key A B C D E F G H I J Switch S1 TIME DELAY Switch S2 PROGRAM SELECTION Relay 2 ENERGIZED Relay 1 DE-ENERGIZED 32 way Euro card connector LED OPERATION Pushbutton TEST LED VALVE CLOSED LED VALVE OPEN Fixing screws 3

4 Contents Important Notes Page Safety note... 6 Warning...6 Explanatory Notes Scope of supply...7 System description... 7 Function...7 Design...7 Technical data...8 Installation Design c / d...9 Attention...9 Tools... 9 Wiring Design c / d...10 Wiring diagram...10 Key to wiring diagram...10 Attention...11 Note...11 Basic Adjustments Select opening mode of the valve...12 Table 1 Opening mode of the valve...12 Adjust time delay...12 Table 2 Time delay...12 Commissioning Warning...13 Check valve function...13 Check wiring...13 Apply mains voltage...13 Check test function...13 Check switching function

5 Contents continued Annex Page Warning...14 Fault finding list...14 Declaration of conformity

6 Important Notes Safety note Use the cycling timer PRS 9 only in combination with GESTRA level switches NRS 2-4. Installation must only be performed by qualified staff. Qualified staff are those persons who through adequate training in electrical engineering, the use and application of safety equipment in accordance with regulations concerning electrical safety systems, and first aid & accident prevention have achieved a recognised level of competence appropriate to the installation and commissioning of this critical safety device. Warning The terminal strip of the PRS 9 is live during operation. This presents the danger of electric shock. Cut off power supply before opening the equipment and before inserting or removing the 19" slide-in unit. 6

7 Explanatory Notes Scope of supply PRS 9, design c 1 Cycling timer type PRS 9 2 Guide rails 1 32pole screw-type connector 1 Installation instructions PRS 9, design d 1 Cycling timer type PRS 9 1 Installation instructions System description The PRS 9 is an analogue/digital cycling timer. In combination with up to four level switches type NRS 2-4 / NRS 2-5 and a position-controlled limit switch the cycling timer can, as part of a controlled draining system in a power station, control drain valves as a function of time. Function Signals coming to the inputs of the level switches and the position-controlled limit switch will be processed electronically, with the time delay adjusted in the equipment being taken into account. Dependent on the adjustment the drain valve will be controlled in one or two steps with a time delay. Design Design c 19" slide-in unit with guide rails and 32pole screw-type connector for installation in 19" magazine acc. to DIN 41494, part 5. Design d 19" spare slide-in unit 7

8 Technical data Supply voltage 24 V DC Power consumption 4 VA Input Three control inputs (volt-free relay contacts) Control voltage 12 V DC Output 2 volt-free relay contacts Max. contact rating with a switching voltage of 24 V, 115 V and 230 V AC: 4 A resistive, 0.75 A inductive at cos ϕ 0.5. Max. contact rating with a switching voltage of 24 V DC: 4 A. Service life of the relays: 30 x 10 6 switching cycles. Indicators and adjustors 1 green LED OPERATION, 1 red LED VALVE OPEN, 1 red LED VALVE CLOSED 1 pushbutton TEST (simulating alarm signalled by P1) 1 switch (on the circuit board) for program selection 1 switch (on the circuit board) for time delay setting Protection IP 10 to DIN Admissible ambient temperature 0 C to +70 C Case 19" slide-in unit with front panel to DIN part 5 and rear 32 way Euro card connector to DIN for installation onto 19" magazine. Front panel: Aluminium Wiring via 32 pole screw-type connector at the back of the 19" magazine, max. conductor size 1.5 mm 2 Weight approx. 0.6 kg 8

9 Installation Design c / d 1. Install the guide rails and the screw-type connector in the 19" magazine. 2. Introduce the 19" slide-in unit onto the guide rails until it hits the stop. 3. Tighten the fixing screws J. Tools Attention To provide sufficient ventilation, ensure a minimum spacing of 20 mm between adjacent units. Screwdriver for slotted screws, size 5, completely insulated according to VDE

10 Wiring Design c / d Wiring is effected via the 32 pole screw-type connector. Wiring diagram PRS Fig Key to wiring diagram P2 Level switch NRS 2-4 or NRS 2-5 (24 V DC) from corresponding level electrode 2 Position-controlled limit switch of the drain valve P1 Level switch NRS 2-4 or NRS 2-5 (24 V DC) from level electrode 1 Rel 2 for opening the drain valve Rel 1 for closing the drain valve 10

11 Attention Fuse supply cable with T 2.5 ma. When switching off inductive loads, voltage spikes are produced that may impair the operation of control and measuring systems. Inductive loads should be provided with commercial arc suppressor RC combinations, e. g. 0.1 µf/100 Ω. Note Connect only volt-free relay contacts to the control inputs. The cycling timer PRS 9 supplies a 12 V DC control voltage. 11

12 Basic Adjustments Select opening mode of the valve Use switch S2 B for selecting the opening mode, see table 1. Table 1 Opening mode of the valve Switch position Opening mode of the valve 1 Two-step opening of the valve 2 One-step opening of the valve Adjust time delay Use switch S1 A for setting the time delay, see table 2. Table 2 Time delay Switch position Time delay 1 5 sec sec sec sec sec sec. 12

13 Commissioning Warning The terminal strip of the PRS 9 is live during operation. This presents the danger of electric shock. Cut off power supply before undertaking any work at the equipment and before inserting or removing the 19" slide-in unit. Check valve function 1. Drive drain valve manually into the mid-position. 2. Apply mains voltage for about 10 sec. P1 and P2 must not give a signal and check whether the valve moves into the closed position. Check wiring 1. Check whether the 19" slide-in unit has been properly introduced into the magazine. 2. Check whether the equipment has been wired in conformity with the mains voltage. Apply mains voltage 1. Switch on the mains voltage and check the equipment for power supply. The LED F functions as visual check. Check test function 1. Push button G and check whether the valve is opening. 2. Press and hold down button G until the valve has reached the position of the limit switch and the actuator has been switched off. 3. Release button G and check whether the valve returns to the closed position after the preset time delay has elapsed. Check switching function To check the switching functions raise or lower the water level until the switchpoints are reached or simulate the corresponding signals by disconnecting the control inputs of P1 3 and P2 1, Fig P1 and P2 are not giving signals: Check whether LED H is illuminated, REL1 D is energized and the valve is closing. 2. P1 or P2 is giving a signal: Check whether the LED I is illuminated, REL2 C is energized and the valve is opening. 3. P2 or if the valve is controlled only by P1 P1 is not giving a signal or the valve is in the intermediate position, no LED illuminated: Check whether the LED H lights up after the time delay, REL 1 D is energized and the valve is closing. 13

14 Annex Warning The terminal strip of the PRS 9 is live during operation. This presents the danger of electric shock. Cut off power supply before opening the equipment and before inserting or removing the 19" slide-in unit. Fault finding list The LED F is not illuminated after applying the mains voltage Fault: The mains voltage has not been switched on. Remedy: Switch on the mains voltage. Check the 19" slide-in unit for correct installation. No or incorrect functions Fault: The internal circuitry is defective. Remedy: Replace the cycling timer. Declaration of conformity We hereby declare that the equipment PRS 9 conforms to the following European guidelines: LV guideline 73/23/EWG version 93/68/EWG EMC guideline 89/336/EWG version 93/68/EWG which are based on the following harmonised standards: LV standard EN : 1991 EMC standard EN , EN This declaration is no longer valid if modifications are made to the equipment without consultation with us. Bremen, 28th April 1997 GESTRA GmbH Dr. Anno Krautwald Dr. Christian Politt 14

15 15

16 GESTRA Gesellschaften GESTRA Companies Sociétés GESTRA Sociedades Gestra Società GESTRA Vertretungen weltweit Agencies all over the world Représentations dans le monde entier Representaciones en todo el mundo Agenzie in tutto il mondo España GESTRA ESPAÑOLA S.A. Luis Cabrera, E Madrid Tel. 00 (+34) 915/ Fax / ; (+34) (+34) gestra@gestra.es France GESTRA France S.A.R.L. 10 Avenue du Centaure, BP 8263 CERGY F Flowserve CERGY Flow PONTOISE Control S. Cedex A. S. Tél. 10 Avenue (00 33) du Centaure, BP 8263 Fax F (00 33) CERGY PONTOISE CEDEX Tél / Fax 00331/ Great Britain gnation@flowserve.com GESTRA (U.K.) LTD Bancroft Court Hitchin, Italia Hertfordshire, SG5 1PH Tel. ( ) Fax Italgestra ( ) S.r.l Via Carducci 125 l Sesto San Giovanni (MI) Italia Tel / Fax / ITALGESTRA info@italgestra.it S.r.l. Via Carducci 125 l S.S. Giovanni (MI) Tel. (02) Fax (02) Polska GESTRA POLONIA Spolka zz.o.o. Ul. Schuberta 104, P. O.B. Box 7271 PL PL Gdansk 50 Tel. 00 (58) / oder Fax 00 (58) / oder gestra@gestra.pl Portugal GESTRA Portugal PORTUGUESA VALVULAS LDA. Av. Dr. Antunes Guimarães, 1159 P-4100 GESTRA Porto PORTUGUESA VALVULAS LDA. Tel. Av. Dr. (2) Antunes Guimarães, 1159 Fax Porto (2) Tel / Fax / USA gestra@gestra.pt GESTRA Division 10 York Avenue West Caldwell, NJ Tel. (9 73) Fax (9 73) GESTRA GmbH Postfach D GESTRA Bremen GmbH Münchener Hemmstraße Str D Bremen Tel. +49 (0) Fax +49 (0) Internet gestra.gmbh@gestra.de Internet gestra.gmbh@gestra.de A Siebe Unit of Group Flowserve Company Corporation /199c 1997 GESTRA GmbH Bremen Printed in Germany 16

NRG Installation Instructions Level Probe Type NRG A Siebe Group Product 1

NRG Installation Instructions Level Probe Type NRG A Siebe Group Product 1 NRG 211-1 Installation Instructions 810425-00 Level Probe Type NRG 211-1 A Siebe Group Product 1 Dimensions ~80 ~118 97 478 334.5 Fig. 1 43.5 2 Parts Drawings G H I J K F E L D C M N B O A Fig. 2 3 Parts

More information

UNA 26h Stainless Steel Design. Installation Instructions Stainless Steel Steam Trap UNA 26h

UNA 26h Stainless Steel Design. Installation Instructions Stainless Steel Steam Trap UNA 26h UNA 26h Stainless Steel Design Installation Instructions 810589-00 Stainless Steel Steam Trap UNA 26h 1 Capacity Chart QC [kg/h] QH [kg/h] x F (based at saturated steam) [lb/h] 20 000 15 000 10 000 8000

More information

BB 1... BB 2... Installation and Maintenance Instructions Dual-Plate Check Valves BB 1..., BB 2...

BB 1... BB 2... Installation and Maintenance Instructions Dual-Plate Check Valves BB 1..., BB 2... BB 1... BB 2... Installation and Maintenance Instructions 810677-01 Dual-Plate Check Valves BB 1..., BB 2... 1 Contents Important Notes Page 2 Usage for the intended purpose... 8 Safety note... 8 Warning...

More information

GESTRA. GESTRA Steam Systems MK 25/2 MK 25/2S. Installation Instructions Steam Traps MK 25..., DN 40-50

GESTRA. GESTRA Steam Systems MK 25/2 MK 25/2S. Installation Instructions Steam Traps MK 25..., DN 40-50 GESTRA GESTRA Steam Systems MK 25/2 MK 25/2S Installation Instructions 810706-01 Steam Traps MK 25..., DN 40-50 1 Contents Important Notes Usage for the intended purpose... 8 Safety note... 8 Danger...

More information

NRG 16-12, NRG 17-12, NRG 19-12

NRG 16-12, NRG 17-12, NRG 19-12 GESTRA GESTRA Steam Systems NRG 16-12 NRG 17-12 NRG 19-12 Installation Instructions 818626-00 Level Electrode NRG 16-12, NRG 17-12, NRG 19-12 Contents Important Notes Page Usage for the intended purpose...4

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

GESTRA. GESTRA Steam Systems ZK 313 ASME. Installation Instructions Control Valve ZK 313 ASME

GESTRA. GESTRA Steam Systems ZK 313 ASME. Installation Instructions Control Valve ZK 313 ASME GESTRA GESTRA Steam Systems ZK 313 ASME Installation Instructions 818542-00 Control Valve ZK 313 ASME 1 Contents Important Notes Usage for the intended purpose... 4 Safety note... 4 Danger... 4 Attention...

More information

UNA 23 UNA 25 UNA 26 UNA 27

UNA 23 UNA 25 UNA 26 UNA 27 GESTRA Steam Systems UNA 23 UNA 25 UNA 26 UNA 27 EN English Installation Instructions 810516-09 Steam Traps UNA 23, UNA 25, UNA 26, UNA 26h Stainless Steel, UNA 27h Contents Important Notes Page Usage

More information

UNA 23 UNA 25 UNA 26 UNA 27

UNA 23 UNA 25 UNA 26 UNA 27 GESTRA GESTRA Steam Systems UNA 23 UNA 25 UNA 26 UNA 27 Installation Instructions 810516-06 Steam Traps UNA 23, UNA 25, UNA 26, UNA 26h Stainless Steel, UNA 27h 1 Contents Important Notes Page Usage for

More information

OR 52-5 OR 52-6 Installation Instructions

OR 52-5 OR 52-6 Installation Instructions OR 52-5 OR 52-6 Installation Instructions 810731-01 Oil & Turbidity Detector OR 52-5, OR 52-6 Component Parts I A B Y Z C X W V U D P T R S Q O P N G L K M F E J I H 2 Key A B C D E F G H I J K L M N O

More information

Conductivity Switch LRGS Original Installation Instructions English

Conductivity Switch LRGS Original Installation Instructions English Conductivity Switch LRGS 15-1 EN English Original Installation Instructions 818758-02 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 LV (Low Voltage) Directive

More information

BA 46 BA 46-ASME BA 47 BA 47-ASME BAE BAE ASME BAE BAE ASME

BA 46 BA 46-ASME BA 47 BA 47-ASME BAE BAE ASME BAE BAE ASME GESTRA GESTRA Steam Systems BA 46 BA 46-ASME BA 47 BA 47-ASME BAE 46... BAE 46...-ASME BAE 47... BAE 47...-ASME Installation Instructions / Product Information 818609-02 Continuous Blowdown Valve BA 46

More information

Steam Trap MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

Steam Trap MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2 Steam Trap MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2 Original Installation Instructions 810348-10 Contents Preface...3 Availability...3 Text layout...3 Safety...3 Usage for the intended purpose...3 Basic safety

More information

Level Electrode NRG NRG NRG NRG

Level Electrode NRG NRG NRG NRG Level Electrode NRG 16-11 NRG 17-11 NRG 19-11 NRG 111-11 EN English Original Installation Instructions 818578-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4

More information

Installation Instructions Spector compact Conductivity Transmitter System LRGT 16-1

Installation Instructions Spector compact Conductivity Transmitter System LRGT 16-1 Installation Instructions 810701-00 Spector compact Conductivity Transmitter System LRGT 16-1 IMPORTANT NOTES...4 SAFETY NOTES...4 Danger...4 EXPLANATORY NOTES...4 Scope of supply...4 System description...4

More information

BA 46 BA 46-ASME BA 47 BA 47-ASME BAE BAE ASME BAE BAE ASME

BA 46 BA 46-ASME BA 47 BA 47-ASME BAE BAE ASME BAE BAE ASME Continuous Blowdown Valve BA 46 BA 46-ASME BA 47 BA 47-ASME BAE 46... BAE 46...-ASME BAE 47... BAE 47...-ASME BA 46 / BA 46-ASME, PN 40/CL 150/300, DN 15-DN 50 BA 47 / BA 47-ASME, PN 63/CL 600, DN 25,

More information

UNA 13 UNA 15 UNA 15 Stainless Steel Design. Installation Instructions Steam Traps UNA 13, UNA 15

UNA 13 UNA 15 UNA 15 Stainless Steel Design. Installation Instructions Steam Traps UNA 13, UNA 15 UNA 13 UNA 15 UNA 15 Stainless Steel Design Installation Instructions 810604-01 Steam Traps UNA 13, UNA 15 1 Contents Important Notes Page Use... 7 Safety note... 7 Danger... 7 Explanatory Notes Scope

More information

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN Operating instructions Rotary actuators M135 M140 M150 M180 June 2012 / 118614 / EN General information General information Proof of amendment Copyright Subject to alterations Manufacturer Version Date

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

Condensate Drain Valve AK 45. Original Installation Instructions English

Condensate Drain Valve AK 45. Original Installation Instructions English Condensate Drain Valve AK 45 EN English Original Installation Instructions 810467-03 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED (Pressure

More information

DKG-114 MANUAL AND REMOTE START UNIT

DKG-114 MANUAL AND REMOTE START UNIT DKG-114 MANUAL AND REMOTE START UNIT FEATURES Both manual and remote controlled engine starting and stopping, Automatic shutdown on fault condition, Optional cooldown cycle on remote start operation, Optional

More information

Operating Instructions for Plastic Flow Meter. Model: KSK

Operating Instructions for Plastic Flow Meter. Model: KSK Operating Instructions for Plastic Flow Meter Model: KSK 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...

More information

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal... Safety sensor BNS Disassembly and disposal. Disassembly..... Disposal... EU Declaration of conformity Operating instructions.............pages to Original x.000 / 0.0 / v.a. - 09009- / J / 0-0-0 / AE-Nr.

More information

Actuator size P2 P3 P4 P5 Diaphragm area cm Thrust max. dan Stroke mm

Actuator size P2 P3 P4 P5 Diaphragm area cm Thrust max. dan Stroke mm Pneumatic s Series 2, Types P2, P3,, Description Standard linear actuators for control valves: Standard actuator made from stainless steel Air supply up to 6 bar Multi-spring design Reversible Top handwheel

More information

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15 17 Elster GmbH Edition 1.17 Translation from the German 519 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve for gas VG VG 15/1 Contents Solenoid valve for gas

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

Flask shaker SF1. Instructions for use Manuel d'utilisation Istruzioni per l uso Instrucciones de funcionamiento Bedienungsanweisung. Version 2.

Flask shaker SF1. Instructions for use Manuel d'utilisation Istruzioni per l uso Instrucciones de funcionamiento Bedienungsanweisung. Version 2. flask shaker Flask shaker Instructions for use Manuel d'utilisation Istruzioni per l uso Instrucciones de funcionamiento Bedienungsanweisung Version 2.0 English flask shaker Mains On/Off Indicator light

More information

Mounting and Operating Instructions EB 5868/5869 EN

Mounting and Operating Instructions EB 5868/5869 EN Electric Control Valves Types 3213/5857, 3213/5824, Types 3214/5824, 3214/3374, 3214/3274 with safety function: Types 3213/5825, 3214/5825, 3214/3374, 3214/3274 Pneumatic Control Valves Types 3213/2780-1,

More information

Softstarter SAS SAS 11PUST, 22PUST Assembly- and Commissioning Instructions

Softstarter SAS SAS 11PUST, 22PUST Assembly- and Commissioning Instructions electronic Softstarter SAS 3...11 SAS 11PUST, 22PUST Assembly- and Commissioning Instructions Quality is our Drive. SAS 3...11, SAS 11PUST, 22PUST 1 Stand 03/17 10800.10002 Table of contents Page 1. Safety

More information

Electric Lowering & Raising System 20kg PRODUCT TYPE. Max. weight of light fitting Lowering distance. 4. Lamp circuits. No. of circuit No.

Electric Lowering & Raising System 20kg PRODUCT TYPE. Max. weight of light fitting Lowering distance. 4. Lamp circuits. No. of circuit No. Electric Lowering & Raising System The cost effective maintenance solution for luminaires FEATURES Designed for use of heavier weight light fittings. TYPICAL APPLICATIONS Workshops, Factories, Warehouses

More information

Clamping and drive module

Clamping and drive module Clamping and drive module RE 51147/10.05 Replaces: 04.02 1/14 Type UPE 3 Drive power 3.0 kw / 4.0 kw Series 1X Maximum operating pressure 700 bar H6842 Overview of contents Contents Page Features 1 Application

More information

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10. 27 Elster GmbH Edition.7 Translation from the German 344297 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve Contents Solenoid valve... Contents... Safety....

More information

GESTRA DISCO Non-Return Valves RK 41, PN 16. Non-Return Valves PN 6/10/16 DN (½ 8") RK 41, PN 16. Application for liquids, gases, vapours.

GESTRA DISCO Non-Return Valves RK 41, PN 16. Non-Return Valves PN 6/10/16 DN (½ 8) RK 41, PN 16. Application for liquids, gases, vapours. GESTRA DISCO Non-Return Valves RK 41, PN 16 Gestra Steam Systems GESTRA Non Return Valves RK 41 PN 6/10/16 15-200 (1/2" - 8") Issue Date: 8/01 Non-Return Valves PN 6/10/16 15 200 (½ 8") RK 41, PN 16 A2

More information

Instruction Manual. Ex-Time 40 / 50

Instruction Manual. Ex-Time 40 / 50 Instruction Manual Ex-Time 40 / 50 Contents 1. Introduction 13 2. Safety Advice 13 3. Faults and Damage 13-14 4. Safety Regulations 14 5. Ex-Data 14-15 6. Technical Data 15-16 7. Use and Application /

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Conveyor Belt Misalignment Switch Type MRS 001 Device Identification No.: 91.055 301.001 OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national

More information

Operating Instruction Manual for Energy Management System EBL 99 C, Art.-Nr Seite 1 / 7

Operating Instruction Manual for Energy Management System EBL 99 C, Art.-Nr Seite 1 / 7 EBL 99 C, Art.-Nr. 911.413 Seite 1 / 7 Contents 1. Description 2. Safety Information 3. Operating Instructions 4. Transport, Storage, Installation 5. Electrical Installation 6. Power-Up, Shut-Down, Maintenance

More information

High ingress protection ratings make a difference REO EMC-Filter with IP66

High ingress protection ratings make a difference REO EMC-Filter with IP66 High ingress protection ratings make a difference REO EMC-Filter with IP High protection classes up to IP for REO EMC filter The use of electrical and electronic equipment continues to increase, for example

More information

Operating Instructions for Paddle Bellows Flow Monitor. Model: FPS-P...

Operating Instructions for Paddle Bellows Flow Monitor. Model: FPS-P... Operating Instructions for Paddle Bellows Flow Monitor Model: FPS-P... 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 4 5. Operating Principle... 5 6. Mechanical

More information

Operating instruction and technical description

Operating instruction and technical description Operating instruction and technical description EV Simulator for charging devices with charging plug / charging coupler / charging cable type 1 and type 2 as service case Photo: EV simulator/tester with

More information

Door Control Panel TS 960. instructions. (Design and functions subject to change) /

Door Control Panel TS 960. instructions. (Design and functions subject to change) / Electrical operating Operating instructions Door Control Panel TS 960 GB (Design and functions subject to change) 51171098 / 10.2002 OPERATING INSTRUCTIONS PAGE SAFETY DIRECTIONS...4 FUNCTION OVERVIEW...6

More information

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content Solenoid interlock AZM 11../.. 1. About this document Operating instructions.............pages 1 to ranslation of the original operating instructions 1.1 Function his operating instructions manual provides

More information

Operating manual UPS - System

Operating manual UPS - System Operating manual UPS - System POWERMASTER M MIL 1000VA 7Min. BAX 3330 E UPS-Division Issued 15. August 2006 JOVYATLAS JOVYATLAS Elektrische Umformtechnik GmbH Groninger Straße 29-37 D-26789 Leer/Ostfriesland

More information

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national regulations. Conformity has been

More information

PKP Prozessmesstechnik GmbH Borsigstraße 24 D Wiesbaden-Nordenstadt Tel.: ++49-(0) Fax: ++49-(0)

PKP Prozessmesstechnik GmbH Borsigstraße 24 D Wiesbaden-Nordenstadt Tel.: ++49-(0) Fax: ++49-(0) P Prozessmesstechnik GmbH Borsigstraße D-6505 Wiesbaden-Nordenstadt Tel.: ++9-(0)6-7055-0 Fax: ++9-(0)6-7055-50 Email: info@pkp.de Instruction Manual FS0 - FS - FS0 Magnetic Float Switch The following

More information

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content 1. About this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning

More information

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-..

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-.. Operating Instructions for Polysulfone Paddle Monitor Model: -.. 1. Contents 1. Contents... 2 2. Note... 3 3. Regulation Use... 3 4. Operating Principle... 3 5. Instrument Inspection... 4 6. Mechanical

More information

MINI MCR-SL-UI-UI(-SP)(-NC)

MINI MCR-SL-UI-UI(-SP)(-NC) Configurable 3-Way Isolating Amplifier Data Sheet 04/2005 Functions Features The configurable 3-way isolating amplifier MINI MCR-SL-UI-UI(-SP)(-NC) is used to electrically isolate, condition, amplify,

More information

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Safety Relay Unit Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Two-pole slim models that are only 22.5 mm wide, three-pole models that are only 68 mm wide,

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Emergency Cord Switch Type PRS Device identification No.: 91.054 033.001, /.101 and /.201 OPERATING INSTRUCTIONS 2 CE Sign and Conformity The device meets the requirements of the valid European and national

More information

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies Data sheet Redundancy unit -A-RU Accessory for range power supplies ABB s redundancy units are used to establish true redundancy which increases the availability of electrical systems significantly. 2CDC

More information

1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it.

1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it. RC SCOPE This test procedure covers the testing and maintenance of Westinghouse RC relays. The Westinghouse Protective Relay Division was purchased by ABB, and new relays carry the ABB label. Refer to

More information

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7 EBL 208, Art.-No 911.430 Seite 1 / 7 Contents 1. Description 2. Safety Information 3. Operating Instructions 4. Transport, Storage, Installation 5. Electrical Installation 6. Power-Up, Shut-Down, Maintenance

More information

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content Solenoid interlock AZM 11../.. 1. About this document Operating instructions.............pages 1 to ranslation of the original operating instructions 1.1 Function his operating instructions manual provides

More information

M A N U A L. Field Current Controller F2.2

M A N U A L. Field Current Controller F2.2 M A N U A L Field Current Controller F2.2 Industrie Elektronik G m b H Hans-Paul-Kaysser-Straße 1 71397 Leutenbach Nellmersbach Tel.: 07195 / 92 83 0 Fax: 07195 / 92 83 129 info@unitek-online.de www.unitek-online.de

More information

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle Thyristor power controller TE10A Burst-firing Single-cycle Advanced Single-cycle Control of short-wave infrared elements and loads of constant resistance up to 20kW User Manual Copyright Eurotherm Automation

More information

REVISED ATM72 Auto Transfer Module

REVISED ATM72 Auto Transfer Module Capricorn Controls DA01ATM1-1 Data & Application Note Page 1 of 8 REVISED - - - ATM72 Auto Transfer Module Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom

More information

Product features & Overview. KA Linear actuators

Product features & Overview. KA Linear actuators Product features & Overview Linear actuators 66 Linear actuators Linear actuator Product features Wide range of force outputs Solid metal housing Large stroke range Maintenance-free gearbox Wide range

More information

System 2000 DRA automatic stairway lighting, Impulse insert. 1 Safety instructions. 2 Device components

System 2000 DRA automatic stairway lighting, Impulse insert. 1 Safety instructions. 2 Device components DRA automatic stairway lighting Order-No. : 0821 00 Impulse insert Order-No. : 0336 00 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically

More information

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS ACTUATOR LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS PRODUCT HANDBOOK APPLICATION The LKS 160 air damper actuator is designed to be fitted to multi-stage or modulating oil and gas burners

More information

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer A company of ThyssenKrupp Elevator ThyssenKrupp Aufzugswerke Operating Manual Oil buffer OPERATING MANUAL Printer s imprint All rights reserved. Copyright by: THYSSENKRUPP AUFZUGSWERKE GMBH P.O. box 23

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

D58 Series Brake Instructions

D58 Series Brake Instructions D58 Series Brake Instructions 4740 W. Electric Avenue Milwaukee, WI 53219 414/672-7830 FAX 414/672-5354 www. dingsbrakes.com Safety information 2 Safety information 2.1 Persons responsible for the safety

More information

Capanivo Series CN 4000

Capanivo Series CN 4000 Capanivo Series CN 4000 Instruction manual 010516 1 UWT GmbH Westendstraße 5 Tel.: +49 (0)831 57123-0 Internet:www.uwt.de D-87488 Betzigau Fax: +49 (0)831 76879 E-Mail: info@uwt.de Scope of this instruction

More information

Kämmer Series Corrosive Application Valves

Kämmer Series Corrosive Application Valves Kämmer Corrosive Application Valves 1 Introduction Optional test port NPT ¼" Anti-blowout stem design Guided stem PN 16 modified PTFE bellows seal,as standard configuration Metal to metal body/bonnet connection

More information

IQL Helios Area-/Streetlight. User Manual

IQL Helios Area-/Streetlight. User Manual Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description... 5 5. Specifications... 6 5.1 General... 6 5.2 Dimensions... 6 6. Installation...

More information

STAUFF STAUFF. Local solutions for individual customers worldwide. Medium Pressure Filters SMPF FILTRATION TECHNOLOGY

STAUFF STAUFF. Local solutions for individual customers worldwide. Medium Pressure Filters SMPF FILTRATION TECHNOLOGY STAUFF THIS IS STAUFF RESPONSE AND FLEXIBILITY COMPETENT SERVICE PROMPT DELIVERY ENSURED QUALITY FRIENDLY SERVICE PROVEN IN PRACTICE Australia Stauff Corporation (Pty.) Ltd. P.O.Box 227, 24-26 Doyle Avenue,

More information

Operating Instructions for Paddle Flowswitch Model: PPS-...

Operating Instructions for Paddle Flowswitch Model: PPS-... Operating Instructions for Paddle Flowswitch Model: PPS-... 1. Note Please read and take note of these operating instructions before unpacking and commissioning. The instruments may only be used, maintained

More information

Uninterruptible power supply Supply MEg101.4

Uninterruptible power supply Supply MEg101.4 Uninterruptible power supply Supply MEg101.4 MEgA Měřící Energetické Aparáty, a.s. 664 31 Česká 390 Czech Republic Uninterruptible power supply Supply MEg101.4 Uninterruptible power supply MEg101.4 1/

More information

Katalysator Nr /

Katalysator Nr / Katalysator Nr. 2300-0001 / 2300-3001 Bedienungsanleitung Instruction manual Mode d emploi Istruzioni d uso Instrucciones de servicio Инструкция по эксплуатации 取扱説明書 사용설명서 21-6499 15092017 Made in Germany

More information

MODEL 422 Submersible Pump Controller

MODEL 422 Submersible Pump Controller MODEL 422 Submersible Pump Controller Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or 240VAC, Single-phase or 3-phase Built-in Trip and

More information

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press Plug-In Safety Relay Safety Relay for Machine Control Conforms to EN Standard H Suitable for safety circuits in press machinery, machine tools, and other production machinery Do Not Remove H CE mark (conforms

More information

Technical Manual Electrical Power Supply System T4002

Technical Manual Electrical Power Supply System T4002 Technical Manual Electrical Power Supply System T400 MOZELT GmbH & Co. KG Please observe the following safety information and recommendations before start-up! Copyright: MOZELT GmbH & Co. KG, D-4769 Duisburg

More information

Operating Instructions

Operating Instructions Operating Instructions Ex UPS Combination of > 8265/5 GUBox control panel > 8316 battery box Contents 1 Contents 1 Contents 2 2 General Information 2 3 Safety Instructions 2 4 Conformity to standards 3

More information

Operating instructions. Rotary actuator M130

Operating instructions. Rotary actuator M130 Holter Regelarmaturen GmbH & Co. KG Heizungs-, Lüftungs-, Klimaarmaturen - Industrie- und Kraftwerksarmaturen Operating instructions 306252 / HORA / EN M130 Table of Content Table of Content b List of

More information

Electromotoric actuators

Electromotoric actuators 4 573 SQS35.50, SQS35.53, SQS65.5 with spring return function, without manual adjuster ACVATIX Electromotoric actuators for valves with 5.5 mm stroke SQS35.00, SQS35.03, SQS65, SQS65.2, SQS85.00, SQS85.03

More information

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option HT-10000 Dielectric Withstand Tester 0-10000 Volts AC Output 25mA Leakage Option Instruction Manual COMPLIANCE WESTUSA Dear Customer: Congratulations! Compliance West USA is proud to present you with your

More information

Instructions Manual. Target Disk Flow meter DP-65 / DP-500. Series DP-65 DP-500. instrumentation for fluids

Instructions Manual. Target Disk Flow meter DP-65 / DP-500. Series DP-65 DP-500. instrumentation for fluids instrumentation for fluids Target Disk Flow meter Series DP-65 / DP-500 Instructions Manual DP-65 DP-500 The following instruction manuals are enclosed: AMM Limit Switch Instruction manual AMD Limit Switch

More information

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX ATEX Type Certification marking for type L1X-EX, T1X-EX, T2X-EX Type of protection "d" explosion-proof enclosure Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

More information

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content 1. About this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning

More information

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants World Class Power Solutions Rectifiers For Stationary Battery Systems in Nuclear Power Plants General 2 1.1 Application Electronically controlled rectifier assemblies are used in conjunction with suitable

More information

1 Safety instructions. 2 Device components. Light Management Rotary dimmer. Operating instructions

1 Safety instructions. 2 Device components. Light Management Rotary dimmer. Operating instructions with 2-way push switch with 2-way push switch Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire

More information

Operating Instruction Manual for Instrument Panel IT 992 Art.-Nr Page 1 / 5

Operating Instruction Manual for Instrument Panel IT 992 Art.-Nr Page 1 / 5 Art.-Nr. 930.420 Page 1 / 5 Contents 1. Description 2. Safety Infmation 3. Operating Instructions and Display 4. Transpt, Stage, Installation 5. Electrical Installation 6. Power-Up, Maintenance 7. Enclosure

More information

Compact Units for Oil

Compact Units for Oil Compact Units for Oil 1-1203-US Group MKU 0.1, 0.2 or 0.5 l/min MKU1-KW2- MKU2-KW3-20 MKU2-BW3-22 MKU2-KW6-22 These MKU compact units were developed to supply intermittently operated single-line central

More information

Operating Instruction for Electronic Pressure Switch. Model: PDD

Operating Instruction for Electronic Pressure Switch. Model: PDD Operating Instruction for Electronic Pressure Switch Model: PDD 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical

More information

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Operating Instructions for Float Flow Meter / Monitor. Model: SWK Operating Instructions for Float Flow Meter / Monitor Model: SWK 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

High Pressure Valves Series Angle Valves Series Angle Valves

High Pressure Valves Series Angle Valves Series Angle Valves High Pressure Valves Series 011000 Angle Valves Series 015000 Angle Valves Description High pressure angle valves with split body. Connections manufactured to IG standards. Other high pressure screwed

More information

Electrical operating instructions

Electrical operating instructions en Electrical operating instructions Door control panel TS 958 Software 1.0 - (Design and functions subject to change) 51171324 - c 03.2007 OPERATING INSTRUCTIONS Page SAFETY DIRECTIONS...4 INSTALLATION

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

INSTRUCTION MANUAL. Code 270R SOFT STARTERS FOR ASYNCRONOUS THREE-PHASE MOTORS. Motori, azionamenti, accessori e servizi per l'automazione

INSTRUCTION MANUAL. Code 270R SOFT STARTERS FOR ASYNCRONOUS THREE-PHASE MOTORS. Motori, azionamenti, accessori e servizi per l'automazione INSTRUCTION MANUAL Code 270R SOFT STARTERS FOR ASYNCRONOUS THREE-PHASE MOTORS CONFORMITY EMC Motori, azionamenti, accessori e servizi per l'automazione Via Ugo Foscolo, 20 - CALDOGNO - VICENZA - ITALIA

More information

Electromotoric Actuators

Electromotoric Actuators 4 506 Electromotoric Actuators for valves with 90 angle of rotation operating voltage AC 230 V 3-position control signal Nominal angle of rotation 90 Auxiliary switch and potentiometer for extra functions

More information

DIAMOND POINT VIBRATING PROBES

DIAMOND POINT VIBRATING PROBES DIAMOND POINT VIBRATING PROBES DP130 DP120 DP140 DP150 Instruction Manual Third revision, April 2016 Hycontrol Ltd., Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, U.K. Tel: + 44 (0)1527

More information

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from Omron STI Application Support Thank you for your interest in Omron STI products. Please contact Omron STI with your application questions. Support Engineers are available at our USA headquarters from 4:00

More information

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30 Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable

More information

WK 120QMM-6M/Z EL 120QMM-6M/M12

WK 120QMM-6M/Z EL 120QMM-6M/M12 Operating instructions Welding system for air arc gouging GB RG12 WK 120QMM-6M/Z EL 120QMM-6M/M12 Observe additional system documents! Register now! For your benefit Jetzt Registrieren und Profitieren!

More information

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type Electropneumatic Converters i/p Converter Type 3913-0001 Fig. 1 Type 3913-0001 Electropneumatic Converter with pressure gauge and bracket Mounting and Operating Instructions EB 3913 EN Edition August 2011

More information

JUMO safetym TB/TW Temperature limiter, temperature monitor according DIN EN

JUMO safetym TB/TW Temperature limiter, temperature monitor according DIN EN JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

ILED Dorado. User Manual

ILED Dorado. User Manual 10NM U-code Medium Intensity Obstruction Light Helideck Status Light 15NM U-code Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description...

More information

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2 Solid-state Contactor (New Heat Sink Construction) G3PB Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications.

More information

Electro-hydraulic crimping tools SD300-6M / SD400-6M. Art /M / /M. convincing solutions. Video /M Video /M

Electro-hydraulic crimping tools SD300-6M / SD400-6M. Art /M / /M. convincing solutions. Video /M Video /M Electro-hydraulic SMART crimping tools INSTRUCTION MANUAL Electro-hydraulic crimping tools SD300-6M / SD400-6M Art. 216663/M / 216667/M Video 216663/M Video 216667/M convincing solutions 1. Technical data

More information