1 Low Voltage Electricity & Water Installations Regulations ADVANCED METERING INFRASTRUCTURE CODE 2016

2 His Highness Sheikh Tameem Bin Hamad Al-Thani Emir of the State of Qatar

3 ADVANCED METERING INFRASTRUCTURE CODE (AMI)

4 Advanced Metering Infrastructure Code CONTENT A. Multi meter case for MSB connection / Multi meter case for LV panel 4 B. Service Cabinet / Electric room connection / Single meter case for MSB / Single meter case 5 for LV panel connection Page Issue : Unclassified 03 of 08

5 Advanced Metering Infrastructure Code (AMI) Amendment to the Regulations for the Installation of Electrical wiring to accommodate the Advanced Metering Infrastructure (AMI) components Additional Field Requirements for AMI In addition to Kahramaa Installations regulations, the below shall be considered for Advanced Metering Infrastructure system (AMI); additional Drawing named Advanced Metering Infrastructure Layout shall become a part of the Building Permit document submission for Kahramaa approval. A. Multi meter case for MSB connection / Multi meter case for LV panel 1) In each / typical floors, provide Two embedded 32 mm PVC conduit (2 nos. x 32 mm) between each group Electricity meters of (max 12 meters) and the corresponding group of Water meters (Between both groups) with pulling and the following embedded es (provide access panels on false ceiling, if required). a. In electricity metering room near to the Main Distribution Board, install 2 Nos. 150mm x 150mm x 100mm size end to connect with the 2 No.s 32 mm PVC conduits. b. In water metering room near corresponding Water meter cabinet, install 2 Nos. 150mm x150mm x 100mm size end to connect with the 2 No.s 32 mm PVC conduits. c. Install 32 mm conduit to connect the above 2 Nos. end Boxes at water metering room (in item b above) to corresponding water meters cabinets Up to 3 cabinets maximum, each of the 2 nos. end es should be connected to each water meter cabinet (when cabinet does not exist stop at group of meters with 150x150x end ) and all conduits should have a pulling (every cabinet suppose to have 4 meters only). d. For every conduit; Install pulling es in every 10-15mtr distance / corner portions. 2) Provide 1 x 32 mm embedded heavy-duty PVC conduit with 5c. 2.5mm 2 cables (R, Y, B, N & E) for interconnecting power supply between the main water meter chamber and nearest ground floor electrical room / LV room and Provide another 1 x 32 mm embedded heavy-duty PVC conduit between the main water meter chamber and The MDF with pulling with the following embedded es: (Pr waterproofing is required for the conduits in main water meter chamber and building retaining wall) a. Install IP65, 150mm x 150mm x 100mm size end near to the Main Distribution Board / LV panel in ground floor electrical room with a 32 mm PVC conduit connecting with pulling at Main LV panel and Install IP65, 150mm x 150mm x 100mm size end near to the MDF. b. In main water meter chamber, install 2 nos. IP65, 100mm x 100mm x 50mm size end on high level and ensure the connection to the 2 nos. 32 mm heavy duty conduits mentioned in point 2 above. c. Install pulling chamber / in every 20-25mtr distance / corner portions. 3) In main LV room a 500mm (Height) x 500mm (Width) provision required on the wall with 100mm x 100mm x 50mm size surface mount type for each data concentrator (AMI Device);. Following additional requirements are to be incorporated. a. Install embedded conduit with 5c. 2.5mm 2 cables (R, Y, B, N & E) from the LV panel-metering compartment to the data concentrator on the wall. Each data concentrator requires a 3ph+N supply from the respective main LV panels, each LV panel will have a Data Concentrator. b. Distance between the data concentrator es shall be minimum 300mm, if two or more main LV panels are in the main LV room. Page 04 of 08

6 4) Provide embedded 38mm PVC conduit for between the MDF panel and main LV rooms with pulling and the following embedded es (provide access panels on false ceiling, if required). a. Install 150mm x 150mm x 100mm size end 30 cm from MDF. b. Install 150mm x 150mm x 100mm size end in main LV room, near to data concentrator. c. In case of more than one concentrator in main LV room (More than one Main LV panel), install 100mm x 100mm x 50mm size near to each data concentrator and install and connect 25 mm conduit between these 100mm x 100mm x 50mm size es and the 100mm x 100mm x 50mm size end in main LV room. d. Install embedded pulling es in every 10-15mtr distance / corner portions. B. Service Cabinet / Electric room connection / Single meter case for MSB / Single meter case for LV panel connection 1) Provide 2 Nos. embedded 25mm PVC conduit between the electrical and water metering cabinets and fix at allocated opening in both cabinets of respective premises (use pipe/cable entrance only in case of no allocated opening) with pulling and install IP65, 100mm x 100mm x 50mm size embedded pulling es in every 20mtr distance / corner portions. 2) Provide 1 Nos. embedded 25mm PVC conduit between Landlord water meter and Landlord Electric meter locations with pulling and install IP65, 100mm x 100mm x 50mm size embedded pulling es in every 20mtr distance / corner portions. Note: In all cases; Distant from relevant eclectic meter should not exceeds 90 meters. Page 05 of 08

7 Field Requirements for AMI (Item A-1) AMI requirement at building for following Method of connection: Multi meter case for MSB connection / Multi meter case for LV panel Same for each floor Same for each floor Same for each floor PVC 32 mm embedded conduit PVC 32 mm Juncti on Water meter cabinet Water meter cabinet PVC 32 mm conduit Water meter cabinet 100 mm m m m Juncti on m m m PVC 32 mm embedded conduit Group of Water Meters Electricity Meter Page 06 of 08

8 Field Requirements for AMI (Item A-2, 3& 4) Main water chamber PVC 32 mm heavy duty conduit with 5c. 2.5 mm2 cables for interconnecting power supply IP65 IP65 Nearest ground floor electrical room/main LV room MDF 50 mm 32 mm conduit 38 mm conduit AMI requirement at building for following Method of connection: Multi meter case for MSB connection / Multi meter case for LV panel m Main DB 32 mm conduit 5c. 2.5mm2 cables (R,Y,B,N&E) from the respective main LV panels pulled in a 32 mm conduit Surface mount type 100mm x 100mm x 50mm 3ph + n supply provision Data concentrator 500 mm 150x150 x 500 mm Same for each Data Concentrator With minimum 300 mm distance IP m 25 mm conduit m IP65 32 mm conduit 150x150 x Page 07 of 08

9 Field Requirements for AMI( Item B) AMI requirement at building for following Method of connection: Service Cabinet/ Electric room connection / Single meter case for MSB connection / Single meter case for LV panel connection Water meter service cabinet Electrical meter service cabinet 20 m 20 m 20 m PVC 25 mm conduit embedded 20 m 20 m 20 m Landlord Water meter when exist Landlord Electric meter when exist 20 m 20 m 20 m PVC 25 mm conduit embedded Page 08 of 08

BOQ FOR ELECTRICAL WORK OF CANARA BANK RENGALI BRANCH

BOQ FOR ELECTRICAL WORK OF CANARA BANK RENGALI BRANCH BOQ FOR ELECTRICAL WORK OF CANARA BANK RENGALI BRANCH 1. WIRING TO POINTS 1 Recess conduit wiring to light, ceiling fan, exhaust fan points with (2x1.5 sq mm + 1(1x1sqmm ) PVC single core copper FRLS wire

More information

B.O.Q FOR ELECTRICAL WORK (Including Fitting & Fixtures) OF STAFF QUARTERS AT BUUBANESWAR FOR UNITED INDIA INSURANCE CO. LTD

B.O.Q FOR ELECTRICAL WORK (Including Fitting & Fixtures) OF STAFF QUARTERS AT BUUBANESWAR FOR UNITED INDIA INSURANCE CO. LTD B.O.Q FOR ELECTRICAL WORK (Including Fitting & Fixtures) OF STAFF QUARTERS AT BUUBANESWAR FOR UNITED INDIA INSURANCE CO. LTD Soubhagya Nayak Associates Plot No-736,Sector-3,Niladrivihar,Chandrasekharpur,Bhubaneswar.21

More information

FINANCIAL BID NAME OF WORK : ELECTRIFICATION WORK AT THE NEW OFFICE PREMISES OF SBI EXCLUSIF KOZHIKODE BRANCH

FINANCIAL BID NAME OF WORK : ELECTRIFICATION WORK AT THE NEW OFFICE PREMISES OF SBI EXCLUSIF KOZHIKODE BRANCH FINANCIAL BID S. No. 1 2 3 4 5 6 7 8 9 10 11 12 NAME OF WORK : ELECTRIFICATION WORK AT THE NEW OFFICE PREMISES OF SBI EXCLUSIF KOZHIKODE BRANCH DESCRIPTION QTY UNITS RATE AMOUNT SETC of a KSEB Metering

More information

B.O.Q ELECTRICAL WORK OF CANARA BANK, BUDHARAJA BRANCH

B.O.Q ELECTRICAL WORK OF CANARA BANK, BUDHARAJA BRANCH B.Q ELECTRICAL WORK OF CANARA BANK, BUDHARAJA BRANCH SL.N 1. WIRING TO POINTS 1.0 Concealed conduit wiring to light, ceiling fan, exhaust fan points with (2x1.5 sq mm + 1(1x1sqmm ) PVC single core copper

More information

Tender Schedule. Sl. No. Particulars Quantity Unit Rate `

Tender Schedule. Sl. No. Particulars Quantity Unit Rate ` Tender Schedule Estimate for Electrical Works at Savalyapuram Branch(18901) Guntur(District). Sl. No. Particulars Quantity Unit Rate ` 1 Wiring for light point/ fan point/ exhaust fan point/ call bell

More information

SCHEDULE OF QUANTITY

SCHEDULE OF QUANTITY SCHEDULE OF QUANTITY ELECTRICAL WORKS PM PALEM BRANCH, VISAKHAPATNAM SL NO. DESCRIPTION OF ITEM / WORK UNIT Qty RATE AMOUNT PART - A : ELECTRICAL WORKS 1 Energy Meter Cubicle : 2 Emergency Off Box (Red

More information

BILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH

BILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH BILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH SL NO. DESCRIPTION OF ITEM / WORK UNIT QTY PART - A : ELECTRICAL WORKS 1 1 Energy Meter Cubicle : a Fabrication, Supply, Installation, testing

More information

SCHEDULE OF QUANTITIES FOR THE ELECTRIFICATION STRUCTURED / DATA CABLING WORKS FOR THE FEDERAL BANK'S

SCHEDULE OF QUANTITIES FOR THE ELECTRIFICATION STRUCTURED / DATA CABLING WORKS FOR THE FEDERAL BANK'S SCHEDULE OF QUANTITIES FOR THE ELECTRIFICATION STRUCTURED / DATA CABLING WORKS FOR THE FEDERAL BANK'S BANK OF INDIA ZONAL OFFICE ANNEX (1 st FLOOR) AT KALOOR TOWERS, K K ROAD, KALOOR A) MAIN PANEL / MSB,

More information

Estimate For The Electrical Works At Pittakayagulla Branch Sl.N Particulars Quantity Unit Rate Amount

Estimate For The Electrical Works At Pittakayagulla Branch Sl.N Particulars Quantity Unit Rate Amount Estimate For The Electrical Works At Pittakayagulla Branch Sl.N Particulars Quantity Unit Rate Amount 1 2 Writing for light point/ fan point/ exhaust fan point /call bell point with 1.5 sq.mm FR PVC insulated

More information

NEC 2011 Code Changes

NEC 2011 Code Changes NEC 2011 Code Changes Articles 280.21-300.50 CHANGES FROM 2008 TO 2011 CODE ARE IN RED Chapter 2 - Wiring and Protection ARTICLE 280 Surge Arresters, Over 1kV III. Connecting Surge Arresters 280.21 Connection

More information

PART B: FINANCIAL BID

PART B: FINANCIAL BID Relationship beyond Bankjng TENDER DOCUMENT FOR ELECTRICAL (ELECTRICAL & DATA CABELING WORK ONLY) IN BANK OF INDIA BRANCH AT SECTOR 25 PANCHKULA BANK OF INDIA, ZONAL OFFICE, S.C.O. NO. 76-82, SECTOR 31-A,

More information

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

INDIAN INSTITUTE OF TECHNOLOGY KANPUR INDIAN INSTITUTE OF TECHNOLOGY KANPUR Tender Notice No. 40/Elect./2018 SCHEDULE OF QUANTITY Name of Work: Electrical work for the Clean Room at NCFlexE IIT Kanpur. Name of the Contractor S. No Description

More information

PART A: FINANCIAL BID

PART A: FINANCIAL BID TENDER DOCUMENT FOR INTERIOR FURNISHING WORKS (excluding ELECTRICAL & DATA CABELING WORK) IN BANK OF INDIA BRANCH AT FARIDABAD,(SME BRANCH), HARYANA BANK OF INDIA, ZONAL OFFICE, STAR HOUSE, S.C.O. NO.

More information

sl. No Description Unit Qty Rate (Rs) Amount (Rs)

sl. No Description Unit Qty Rate (Rs) Amount (Rs) Page 1 of 6 1 MAIN PANEL : Fabrication, Supply, Installation, Testing and commissioning of 415V,50 no 1 Hz, 3 phase,4 wire, Self standing, dust and vermin proof front operated, cubicle type distribution

More information

FREMANTLE PORTS 2015 ELECTRICAL PLANNING FACT SHEET PLANNING BRANCH

FREMANTLE PORTS 2015 ELECTRICAL PLANNING FACT SHEET PLANNING BRANCH FREMANTLE PORTS 2015 ELECTRICAL PLANNING FACT SHEET PLANNING BRANCH Application This fact sheet applies to all Fremantle Ports tenants, particularly those requiring new or increased electrical supply or

More information

Bills of Quantities and Schedule for the Electrical Works at M/s.Bank of India, Madurai CPC Branch, East Aavani Moola Street, Tamil Nadu.

Bills of Quantities and Schedule for the Electrical Works at M/s.Bank of India, Madurai CPC Branch, East Aavani Moola Street, Tamil Nadu. Bills of Quantities and Schedule for the Electrical Works at M/s.Bank of India, Madurai CPC Branch, East Aavani Moola Street, Tamil Nadu. S.No Particulars Qty Unit Rate Rs Amount Rs Service Connection

More information

Estimate For Electrical Works PROPOSED RUDSET INSTITUTE AT BERHAMPUR

Estimate For Electrical Works PROPOSED RUDSET INSTITUTE AT BERHAMPUR Estimate For Electrical Works PROPOSED RUDSET INSTITUTE AT BERHAMPUR Sl No Brief description of work item Unit Qty Rate Amount Total Rs A INTERNAL WIRING Supply, laying of 2mm thick approved make PVC conduit

More information

Annexure-1. Annexure- 1 TECHNICAL SPECIFICATIONS FOR THE MODULAR LABORATORY FURNITURE (CNSNT/RL-4)

Annexure-1. Annexure- 1 TECHNICAL SPECIFICATIONS FOR THE MODULAR LABORATORY FURNITURE (CNSNT/RL-4) Annexure- 1 TECHNICAL SPECIFICATIONS FOR THE MODULAR LABORATORY FURNITURE (CNSNT/RL-4) Item Number-1 ----------------------------------------------------------------------------------------------------------

More information

19 floor rack with steel door

19 floor rack with steel door 2015 Telecommunication rack systems HETEL 1 19 floor rack with steel door Rack width 600 mm Rack width 800mm General features include a metal frame, 19 rails, roof, side and rear panels, door and plinth

More information

FAQ s. Designing metering switchboards as per Victorian service installation rules

FAQ s. Designing metering switchboards as per Victorian service installation rules FAQ s Designing metering switchboards as per Victorian service installation rules Designing metering switchboards as per Victorian service installation rules Q: Who develops the Victorian service installation

More information

Maximum submersible power cable length (max. cable length in feet - starter to motor)

Maximum submersible power cable length (max. cable length in feet - starter to motor) Cable sizing charts V and 0 V, ph V ph 0 V ph 0. 0. 0 (40) 00 (0) 0 (68) 00 0 (9) 90. (8) 0 (46) 0 (7) - 0 (64) 60 (49) 880 (68) (98) 480 (46) 0 90 (8) 0* (4*) 7. 40 (04) 90 (44) 00 () () 60 (9) 480 (46)

More information

ESTIMATE PROPOSED ELECTRICAL & ALLIED WORKS FO INDIA ONE AVIGHNA PARK, CURREY ROAD BRANCH AT C MUMBAI

ESTIMATE PROPOSED ELECTRICAL & ALLIED WORKS FO INDIA ONE AVIGHNA PARK, CURREY ROAD BRANCH AT C MUMBAI ESTIMATE PROPOSED ELECTRICAL & ALLIED WORKS FO INDIA ONE AVIGHNA PARK, CURREY ROAD BRANCH AT C MUMBAI S.N. PARTICULARS QTY UNIT A MAIN LT PANEL / DB'S 1 Supply, installation, testing & commissioning of

More information

to UPS outgoing DB. c With 2 nos. 6 Sq.mm + 1 no. 2.5 Sq.mm. PVC insulated copper wire from UPS outgoing DB to CDB / Main panel to LDB /

to UPS outgoing DB. c With 2 nos. 6 Sq.mm + 1 no. 2.5 Sq.mm. PVC insulated copper wire from UPS outgoing DB to CDB / Main panel to LDB / Bill of Quantity for Electrical & Computer wiring works for Shifting of RACPC Jamshedpur to new location of Jamshedpur Branch Premises S.No. Item Description Qty. Rate Amount 1 UPS DB / COMPUTER DB Supply

More information

Bill of Quantity for Electrical & Computer wiring works for Shifting of SMECC Jamshedpur to Jamshedpur Branch Premises

Bill of Quantity for Electrical & Computer wiring works for Shifting of SMECC Jamshedpur to Jamshedpur Branch Premises Bill of Quantity for Electrical & Computer wiring works for Shifting of SMECC Jamshedpur to Jamshedpur Branch Premises S.No. Item Description Qty. Rate Amount 1 Removing and Reinstallation of Main Incoming

More information

SECTION VII METERING INSTALLATIONS

SECTION VII METERING INSTALLATIONS SECTION VII METERING INSTALLATIONS 1. GENERAL Outdoor metering is required for all new service installations to one, two, and three family detached, semi-detached and row houses. 2. COMPANY FURNISHES AND

More information

Garden Lamps. Product Features. Applications

Garden Lamps. Product Features. Applications V-TAC LED presents the perfect outdoor lighting to make your garden glow after the sun goes down. Step outside with our wide range of contemporary outdoor lighting and decorate your pathways, walls, floors

More information

A. This section includes unit capacitors for power factor correction.

A. This section includes unit capacitors for power factor correction. PART 1: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. 1.02

More information

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount Tender Schedule for Electrical Works at Varagani Branch Sl. No. 1 Particulars Quantity Unit Rate Amount SITC of following rated Indoor operated wall/floor mounted, cubicle type MV cum APFC Panel suitable

More information

JUNCTION BOX FOR CATHODIC PROTECTION

JUNCTION BOX FOR CATHODIC PROTECTION JUNCTION BOX FOR CATHODIC PROTECTION Yuxi manufacture a serious type of junction box required for a cathodic protection system. Our junction box is designed to use reliably for onshore and marine environments

More information

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS REVISION

More information

A. This section includes enclosed dry type transformers for lighting and power loads, with primaries and secondaries rated 600 volts and less.

A. This section includes enclosed dry type transformers for lighting and power loads, with primaries and secondaries rated 600 volts and less. PART 1: GENERAL PART I: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other

More information

Addressing ambiguity in how electricity industry legislation applies to secondary networks

Addressing ambiguity in how electricity industry legislation applies to secondary networks In Confidence Office of the Minister of Energy and Resources Chair, Cabinet Business Committee Addressing ambiguity in how electricity industry legislation applies to secondary networks Proposal 1 This

More information

2 PARK SPECIFICATIONS

2 PARK SPECIFICATIONS 2 PARK 1. DESCRIPTION: SPECIFICATIONS The machine allows parking of two cars or two boats one above the other The machine is semi automatic that enables parking of both cars independently The machine can

More information

LED Outdoor Lights. Product Features. Applications

LED Outdoor Lights. Product Features. Applications LED Outdoor Lights Transform the exteriors of a Building or a Garden into a Beautiful piece of Architecture. Simultaneously help navigate obstacles at night, prevent accidents and provide security. Product

More information

M. C. B. / D. B./MCCB : MDS/Schneider/Siemens/havells

M. C. B. / D. B./MCCB : MDS/Schneider/Siemens/havells Material Specification for Electrical Work Tube Light : Phillips, GE Switches : / Legrand (Artiar )/Anchor roma Wire/Cable : Anchor/Finolex/National /Havells/ CCI Fan : Crompton Greaves ( high Breeze )/USHA

More information

RKB BLITZ Range Rigid conduit

RKB BLITZ Range Rigid conduit RKB BLITZ Range Rigid conduit TECHNICAL CHARACTERISTICS - RKB ISOLATING RIGID SELF-EXTINGUISHING CONDUIT WITH IMQ MARKING STANDARDS: CEI EN 50086-1 and CEI EN 50086-2-1 (CEI 23-54) CLASSIFICATION: 4321

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information

EPIC. Connector Accessories CONNECTOR ACCESSORIES. Glands, Seal Rings & Adapters Glands 412 EPIC SM & SP Glands, EPIC CM-M Glands

EPIC. Connector Accessories CONNECTOR ACCESSORIES. Glands, Seal Rings & Adapters Glands 412 EPIC SM & SP Glands, EPIC CM-M Glands CONNECTOR ACCESSORIES Glands, Seal Rings & Adapters Glands 412 EPIC SM & SP Glands, EPIC CM-M Glands D Series Pressure Screws 413 U Series Washers 413 Sealing Rings 413 Neoprene & Viton Concentric Sealing

More information

Wisconsin Public Utility Institute. June 28, Minimum Distribution Charges. Larry Vogt. Director, Rates Mississippi Power

Wisconsin Public Utility Institute. June 28, Minimum Distribution Charges. Larry Vogt. Director, Rates Mississippi Power Wisconsin Public Utility Institute June 28, 2017 Minimum Distribution Charges Larry Vogt Director, Rates Mississippi Power 1 Costs of Service vs. Cost Recovery Residential Service Example Assuming that

More information

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5 PAGE 1 OF 5 USE: Requirements for entrance equipment. PREVIOUS REVISION 07-01-98 ORIGINATED 03-94 PREVIOUS NUMBER ER 100 (12-01-81) LATEST REVISION: Updated meter socket labeling specification and instrument

More information

Luminous Patterns Panels

Luminous Patterns Panels Luminous Patterns Panels Installation Instructions (English) Preliminary version - Subject to change - Panels must be installed by a qualified electrician in accordance with all national and local electrical

More information

TENDER. Enq. No. IIITMK/ 0648/18 Date: 07/09/18 Due on:17/09/20183pm

TENDER. Enq. No. IIITMK/ 0648/18 Date: 07/09/18 Due on:17/09/20183pm TENDER Enq. No. IIITMK/ 0648/18 Date: 07/09/18 Due on:17/09/20183pm On behalf of INDIAN INSTITUTE OF INFORMATION TECHNOLOGY & MANAGEMENT KERALA (IIITMK), the Registrar invites offers for supply and laying

More information

Proposal to improve and correct the SLR official documents to introduce references to the three new simplified UN Regulations "LSD", "RID" and "RRD".

Proposal to improve and correct the SLR official documents to introduce references to the three new simplified UN Regulations LSD, RID and RRD. Submitted by the expert from GRE-IWG SLR Informal document No. GRE-79-13 (79th GRE, 24-27 April 2018, agenda item 4) Proposal to improve and correct the SLR official documents to introduce references to

More information

Creating An Accessible World ELVORON CPL.

Creating An Accessible World ELVORON CPL. Creating An Accessible World ELVORON CPL Design And Planning Guide www.garaventalift.com Please note: Dimensions provided in this Guide are for REFERENCE ONLY and should not be used for site preparation

More information

In-line Plug-in Design 3NJ6

In-line Plug-in Design 3NJ6 Contents Page - Outgoing Feeders General 6/2 Structure and Functions inclusive Forms of Internal Separation, Installation of Instruments 6/2 Plug-on Bus System 6/2 Cable Connection Compartment 6/2 Switch-disconnector-fuse

More information

I N D I A N S T A T I S T I C A L I N S T I T U T E

I N D I A N S T A T I S T I C A L I N S T I T U T E I N D I A N S T A T I S T I C A L I N S T I T U T E 8 th MILE POST, MYSORE ROAD, BANGALORE Tel : 080 28483002-28483006, Fax 080 22293517, E-mail : isib@isibang.ac.in TENDER DOCUMENT FINANCIAL BID (SUPPLY,

More information

LB - LIGHTING BUSWAY 25-40A

LB - LIGHTING BUSWAY 25-40A 16 LB - LIGHTING BUSWAY 25-40A LIGHTING BUSWAY SECTION CONTENTS 18 General features 24 Trunking components: 2 and 4 conductors elements 28 Trunking components: 6 conductors elements 30 Plugs 33 Fixing

More information

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

INDIAN INSTITUTE OF TECHNOLOGY KANPUR INDIAN INSTITUTE OF TECHNOLOGY KANPUR Tender tice. 21/Elect./2018 SCHEDULE OF QUANTITY Name of Work: Construction of second floor above central block at ACES building (SH: Electrical works). Name of the

More information

AIR CONDITIONING Managing condensate

AIR CONDITIONING Managing condensate www.sauermann.co.uk AIR CONDITIONING Managing condensate Pump selection chart Equipement Location Wall mounted Cassette Multi cassette Conditioning cabinet ALTEZZA DI MANDATA (m) Floor standing Ducted

More information

PROPOSED AMENDMENTS TO HOUSE BILL 3159

PROPOSED AMENDMENTS TO HOUSE BILL 3159 HB - (LC ) // (HE/ps) PROPOSED AMENDMENTS TO HOUSE BILL 0 0 On page of the printed bill, line, delete and amending ORS.. and insert amending ORS.; and declaring an emergency.. Delete lines through and

More information

Document Requirements for Engineering Review- PV Systems v1.1 12/6/2018

Document Requirements for Engineering Review- PV Systems v1.1 12/6/2018 Document Requirements for Engineering Review- PV Systems v1.1 12/6/2018 Outlined below are the engineering documents and their associated minimum detail requirements for a Distributed Energy Resource (DER)

More information

Typical 2 Bay Automatic Standard 2 Bay Using Trench Drain

Typical 2 Bay Automatic Standard 2 Bay Using Trench Drain Typical Bay Automatic Standard Bay Using Trench Drain Trench Drain Slope to Removable P/T Wood Dam for Solids Containment Solid Cover Building Size Determine by location 3 Water Flow and Piping Legend.

More information

E/ECE/324/Rev.2/Add.106/Rev.6/Amend.5 E/ECE/TRANS/505/Rev.2/Add.106/Rev.6/Amend.5

E/ECE/324/Rev.2/Add.106/Rev.6/Amend.5 E/ECE/TRANS/505/Rev.2/Add.106/Rev.6/Amend.5 28 October 2016 Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles, Equipment and Parts which can be Fitted and/or be Used on Wheeled Vehicles and the Conditions

More information

ELECTRICAL INSTALLATION PROCEDURES For Custom Grid Assemblies & Power Generators

ELECTRICAL INSTALLATION PROCEDURES For Custom Grid Assemblies & Power Generators ELECTRICAL INSTALLATION PROCEDURES For Custom Grid Assemblies & Power Generators BECAUSE CLEAN AIR MATTERS Note: Factory trained or suitably qualified personnel must perform this installation. General:

More information

ALUMINIUM PARTITION ALUMINIUM PARTITION AS/DETAIL A ALUMINIUM PARTITION AS/DETAIL C AS/DETAIL C

ALUMINIUM PARTITION ALUMINIUM PARTITION AS/DETAIL A ALUMINIUM PARTITION AS/DETAIL C AS/DETAIL C ALUMINIUM PARTITION ALUMINIUM PARTITION AS/DETAIL A ALUMINIUM PARTITION AS/DETAIL C AS/DETAIL C LEGEND OF FURNITURE CODE S.NO ITEM CODE DESCRIPTION TENDER ITEM NO. QTY.. MET MIDDLE EXE. TABLE(FINESSE)

More information

UniGear. Technical Guide

UniGear. Technical Guide UniGear Technical Guide CONTENTS 0 CONTENTS 1.1 Compartments 1/2 1.2 Components of the structure 1/3 1.2.1 Hot-galvanized steel sheet 1/3 1.2.2 Painted steel sheet 1/4 1.2.3 Copper 1/5 1.2.4 Insulating

More information

ELVORON HR DESIGN AND PLANNING GUIDE

ELVORON HR DESIGN AND PLANNING GUIDE ELVORON HR DESIGN AND PLANNING GUIDE Hydraulic Home Elevator Quality Elevators by Garaventa www.garaventaelevator.com Table of Contents Elvoron HR - Hydraulic Residential Elevator... 2 Technical Reference:...

More information

West Bengal State Electricity Distribution Co. Ltd.

West Bengal State Electricity Distribution Co. Ltd. West Bengal State Electricity Distribution Co. Ltd. TECHNICAL SPECIFICATIONS FOR D. C. DISTRIBUTION BOARD (FOR 33 KV SUB STATIONS) Page 1 of 14 1.0 SCOPE: This specification covers the design, manufacturing,

More information

STATE BANK OF INDIA ADMINISTRATIVE OFFICE -7 : HUBBALLI KUDRIGE BRANCH - REGION 5, KARNATAKA. ELECTRICAL WORKS : SCHEDULE OF ITEMS(BOQ)

STATE BANK OF INDIA ADMINISTRATIVE OFFICE -7 : HUBBALLI KUDRIGE BRANCH - REGION 5, KARNATAKA. ELECTRICAL WORKS : SCHEDULE OF ITEMS(BOQ) FINANCIAL BID STATE BANK OF INDIA ADMINISTRATIVE OFFICE -7 : HUBBALLI KUDRIGE BRANCH - REGION 5, KARNATAKA ELECTRICAL WORKS : SCHEDULE OF ITEMS(BOQ) PART A SL No DESCRIPTION OF WORK QTY UNIT SUPPLY ERECTION

More information

Section 02: Pre-Installation Procedures

Section 02: Pre-Installation Procedures Section 02: Pre-Installation Procedures Foundation! WARNING The MUST be placed on a surface that will support the combined weight of the, options, fixtures, and tooling, etc. (refer to the Specifications

More information

Clark Public Utilities Commercial Electric Service Handbook. This page left blank intentionally.

Clark Public Utilities Commercial Electric Service Handbook. This page left blank intentionally. This page left blank intentionally. 38 Chapter 4: Commercial Metering / January 2011 APPENDIX Glossary Approval Acceptable to the authority having jurisdiction. Associated equipment As related to metering

More information

LED STRIP BROCHURE IP68 A I S I 316L MAC ADAM2 CLEANING AGENTS RESISTANT FROST RESISTANT SEA WATER RESISTANT SWIMMING POOL SUBMERSIBLE UV RESISTANT

LED STRIP BROCHURE IP68 A I S I 316L MAC ADAM2 CLEANING AGENTS RESISTANT FROST RESISTANT SEA WATER RESISTANT SWIMMING POOL SUBMERSIBLE UV RESISTANT LED STRIP BROCHURE IP68 A I S I 316L SEA WATER RESISTANT UV RESISTANT CLEANING AGENTS RESISTANT FROST RESISTANT SWIMMING POOL SUBMERSIBLE MAC ADAM2 liniled LED strips European quality, design & manufacturing

More information

STOREPARKER SERIES STOREPARKER N2503 THE DEPENDENT PARKING SYSTEM ON 3 LEVELS WITHOUT PIT DEPENDENT PARKING SYSTEMS

STOREPARKER SERIES STOREPARKER N2503 THE DEPENDENT PARKING SYSTEM ON 3 LEVELS WITHOUT PIT DEPENDENT PARKING SYSTEMS STOREPARKER SERIES DEPENDENT PARKING SYSTEMS STOREPARKER N2503 THE DEPENDENT PARKING SYSTEM ON 3 LEVELS WITHOUT PIT SHORT DESCRIPTION - DEPENDENT PARKING ON 3 LEVELS, WITHOUT PIT - UPPER LEVELS PROVIDED

More information

Application: Wallmount. Depth: 15mm. Color: 23mm 6150mm. Depth: 19mm. Color: Depth: 25mm. Color: Depth: 27mm. Color: 39mm 6150mm

Application: Wallmount. Depth: 15mm. Color: 23mm 6150mm. Depth: 19mm. Color: Depth: 25mm. Color: Depth: 27mm. Color: 39mm 6150mm TEXTILE FRAMES ECO 15 NF-04150 SILVER NF-21150 BLACK NF-04150PH PUNCHHOLES Application: Wallmount Depth: 15mm 15mm 23mm SIMPLE 19 NF-04190 SILVER NF-21190 BLACK NF-56190 WHITE NF-04190PH PUNCHHOLES Application:

More information

Total Cost Abstract. Project Name : - RDPL, Jaipur. Grand Total

Total Cost Abstract. Project Name : - RDPL, Jaipur. Grand Total Project Name : - RDPL, Jaipur Total Cost Abstract S. No. Description Amount 1 Metering & Distribution Boxes 2 Earthing 3 Point Wiring & Fixtures 4 Data & Voice Grand Total Project Name : - RDPL, Jaipur

More information

TENDER DOCUMENT. TENDER No: SRO/CON/ETS/011 dated

TENDER DOCUMENT. TENDER No: SRO/CON/ETS/011 dated TENDER DOCUMENT TENDER No: SRO/CON/ETS/011 dated 05.09.2018 Tender for Supply, Installation, Testing, Commissioning and Handing Over of Networking system for Third- floor on existing Academic Building

More information

continuous use min hours (expected life time curve in addendum)

continuous use min hours (expected life time curve in addendum) SPECIFICATIONS Model SC 235 A SC 235 B SCI 535 A1 SCI 535 B1 SCI 535 A5 SCI 535 B5 SCR 535 A SCR 535 B SW 535 B SUC 516 A SUC 516 B SULC 516 B SULI 516 B1 SULI 516 B5 SUM 516 A1 SUM 516 A5 SULM 516 B1

More information

FORMAT B (Annexure-III)

FORMAT B (Annexure-III) FORMAT B (Annexure-III) Bill of Quantities AR&M works (Electrical) Residential buildings Part-I (Schedule items) Sl. No. Description of Items Unit Qnty. Rate in figure 01 Point Wiring in PVC Conduit with

More information

33kV Connection up to 90MVA

33kV Connection up to 90MVA Electricity Specification 217 Issue 2 December 2007 33kV Connection up to 90MVA Contents 1 Scope 2 General 3 Connection Arrangements 4 Equipment Records 5 Documentation 6 Documents Referenced 7 Keywords

More information

PARKLINE SERIES PARKLINE N5102 THE SEMI-AUTOMATIC PARKING SYSTEM WITHOUT PIT AND NO COLUMNS AT THE ENTRY SEMI AUTOMATICS SHORT DESCRIPTION

PARKLINE SERIES PARKLINE N5102 THE SEMI-AUTOMATIC PARKING SYSTEM WITHOUT PIT AND NO COLUMNS AT THE ENTRY SEMI AUTOMATICS SHORT DESCRIPTION PARKLINE SERIES SEMI AUTOMATICS PARKLINE N5102 THE SEMI-AUTOMATIC PARKING SYSTEM WITHOUT PIT AND NO COLUMNS AT THE ENTRY SHORT DESCRIPTION - INDEPENDENT PARKING ON 2 LEVELS, WITHOUT PIT - UPPER LEVEL PROVIDED

More information

SCHEDULE OF QUANTITIES OF ELECTRICAL WORKS FOR BOI, ZO, JODHPUR. PART - II

SCHEDULE OF QUANTITIES OF ELECTRICAL WORKS FOR BOI, ZO, JODHPUR. PART - II total connected load= 98.76 kw 1 ELECTRICAL WIRING Providing & fixing POINT WIRING for Ceiling and wall lights. The item includes Circuit wiring from DB to the switch board with 2x2.5 Sq. MM PVC insulated

More information

Screed Floor system LIMOGES Cedex. Phone : Fax :

Screed Floor system LIMOGES Cedex. Phone : Fax : 87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 CONTENTS PAGES 1.Range 1 to 4 2.Installation process 5 to 10 3.Products details 11 to 24 4.Technical characteristics 25 to 26 1 RANGE. Optional

More information

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH 207 CFFWA NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Universal Mount Fan Coil CFFWA- XX - 1 - U 2-Pipe Heat/Cool

More information

FORMAT-III B - ANNEXURE-III

FORMAT-III B - ANNEXURE-III FORMAT-III B - ANNEXURE-III Bill of Quantities AR&M works (Electrical)Residential buildings Part-I (Schedule items) Sl. Description of item Unit Qty No. In Figure Point Wiring in PVC Conduit with piano

More information

HEAVY-DUTY 16 ga, T-304 S/S Ø3 1/2"

HEAVY-DUTY 16 ga, T-304 S/S Ø3 1/2 RU HEVY-DUTY 16 ga, T-304 S/S RU- 20-100 MODEL RU-2720-100 27 24 RU-3020-100 30 27 RU-3320-100 33 30 RU-3620-100 36 33 16 gauge, type 304 stainless MEHNIL asket drains are 1½ IPS. Unibody construction

More information

Customer Requirements Downtown Secondary Network Service

Customer Requirements Downtown Secondary Network Service Application This standard describes the limitations and requirements for receiving service from the Tacoma Power secondary network system within the City of Tacoma downtown core area. In This Standard

More information

Stack Parking Surface Mounted Stackers

Stack Parking Surface Mounted Stackers / 5 Stack Parking Surface Mounted Stackers swiss-park V- Junior The V- is the ideal machine for low ceiling garages. Its angled platform allows space for parking one car over another in garages where stacked

More information

Industrial luminaires

Industrial luminaires Industrial luminaires acciaio When rapidity is money......you install 4 fittings in the time of 1 Industrial luminaires T5 and T8 Material: body: in zinc steel painted color: gray Degree of protection:

More information

HOTLINE ELECTRICAL TRADING

HOTLINE ELECTRICAL TRADING HOTLINE ELECTRICAL TRADING (L.L.C) P.O.Box: 235152 Dubai, UAE. Tel ; +971-4-3455173 Email:-manuel@hletllc.com I www.hletllc.com Company Profile Hotline Electrical Trading L.L.C is a trading company dealing

More information

SEALING PLUGS

SEALING PLUGS SEALING PLUGS 1.7.5.1 General information Product description The PSI plug is a sealing device consisting of two half shells. It is especially designed to seal cables and pipes passing through walls and

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-21023-6 Any reference to SABS 0241 is deemed to be a reference to this standard (Government Notice No. 1373 of 8 November 2002) SOUTH AFRICAN NATIONAL STANDARD Tachograph centres Installation

More information

PRODUCT NEWS Q3 + Q4 2016

PRODUCT NEWS Q3 + Q4 2016 PRODUCT NEWS Q3 + Q4 2016 Carpenters square 33257 STACO Tømrervinkel 800 x 320 mm 5707345332579 1 In stock Power chisel 55579 STACO power chisel, 28 mm, SoftGrip handle w/metal blow bud 5707345555794 12

More information

6 Omnitrack 02_Omnit _15.indd 6 27/04/15 13:18

6 Omnitrack 02_Omnit _15.indd 6 27/04/15 13:18 6 Omnitrack F Omnitrack - 3 circuits 16 7 POWERED TRACKS L2 L3 L1 N 1200/2000/3000/00 Housing: Three-phase track for 3 separate electrical circuits. Extruded aluminium rectangular section, containing an

More information

UNDERGROUND SERVICES - SECONDARY

UNDERGROUND SERVICES - SECONDARY UNDERGROUND SERVICES - SECONDARY Contents - Underground Services... U-1 General Requirements for Underground Service...U-2 Names of Parts for Underground Service... U-3 Service Termination in a Service

More information

Abu Dhabi Conformity Assessment Scheme for Electric Vehicle Supply Equipment

Abu Dhabi Conformity Assessment Scheme for Electric Vehicle Supply Equipment Abu Dhabi Conformity Assessment Scheme for Electric Vehicle Supply Equipment Page i Amendment Page To ensure that each controlled copy of this conformity assessment scheme contains a complete record of

More information

Chapter 6 Generator-Voltage System

Chapter 6 Generator-Voltage System Chapter 6 Generator-Voltage System 6-1. General The generator-voltage system described in this chapter includes the leads and associated equipment between the generator terminals and the low-voltage terminals

More information

Arena-Walsall power track system standard

Arena-Walsall power track system standard standard Standard track length SL12 Standard feeder unit SFU Standard tap-off SO3U Standard SFB 1 Dimensions and technical information (p. 198-199) wo bar and earth 63 power track system Pack Cat. Nos.

More information

PUBLIC UTILITY DISTRICT NO. 1 OF LEWIS COUNTY METERING SPECIFICATIONS

PUBLIC UTILITY DISTRICT NO. 1 OF LEWIS COUNTY METERING SPECIFICATIONS PUBLIC UTILITY DISTRICT NO. 1 OF LEWIS COUNTY METERING SPECIFICATIONS 1. General Metering Requirements a. Interpretation The District s metering requirements shall not be interpreted to conflict with the

More information

CORRIGENDUM/ ADDENDUM 09 ADDITIONAL REQUIREMENT OF ELEVATOR.

CORRIGENDUM/ ADDENDUM 09 ADDITIONAL REQUIREMENT OF ELEVATOR. AMENDMENT-02 TO TECHNICAL SPECIFICATION FOR ELEVATOR (SPEC NO. PE-TS-408-502-A001) 1x800 MW WANAKBORI STPP. CORRIGENDUM/ ADDENDUM 09 ADDITIONAL REQUIREMENT OF ELEVATOR. CL. NO. 2.0 Scope of equipment supply

More information

FORMAT-III B - ANNEXURE-IV

FORMAT-III B - ANNEXURE-IV FORMAT-III B - ANNEXURE-IV Bill of Quantities AR&M works (Electrical) Non-Residential buildings Part-I (Schedule items) Sl. No. 1 Description of item Unit Qty Point Wiring in PVC Conduit with piano type

More information

Approved Contractor Construction e-guide Residential Commercial

Approved Contractor Construction e-guide Residential Commercial Approved Contractor Construction e-guide Residential Commercial Clark Public Utilities PO Box 8900 Vancouver, WA 98668 (PAGE 2) TABLE OF CONTENTS PAGE Trenching 3 Wire 8 Single-Phase Transformer Set 13

More information

Have You Been Grounded Lately

Have You Been Grounded Lately Have You Been Grounded Lately Thurs, Oct. 26, 2017 9:15-10:15 Phil Simmons Author, Electrical Grounding and Bonding Author Cengage Learning Phil Simmons Have You Been Grounded Lately 2017 NEC Changes Relative

More information

Rated voltage (V) Current (A) Stranded wire. Solid wire A.D.O. (AWG)

Rated voltage (V) Current (A) Stranded wire. Solid wire A.D.O. (AWG) Characteristics (1) Dimensions are on DIN 3 rail : PR4 (Height 15 mm) Use of a PR3 rail : remove 7,5 mm on dimension B Use of a DIN 1 rail : remove 2,5 mm on dimension B remove 5 mm on dimension C Miniblocks

More information

energy waste Putting a stop to

energy waste Putting a stop to Putting a stop to energy waste XX energy saving With lighting accounting for up to 20% of a commercial building s electricity use, the efficient control of lighting across all areas is a vital tool in

More information

Garden Lamps. Product Features. Applications

Garden Lamps. Product Features. Applications Garden Lamps V-TAC presents an elegant series of garden lighting- allowing your garden to glow in style when the sun goes down.step outside with our wide range of contemporary outdoor lighting and decorate

More information

Market Domain Data Lookup tables SP Distribution Effective from 1 April 2008

Market Domain Data Lookup tables SP Distribution Effective from 1 April 2008 Market Domain Data Lookup tables SP Distribution Effective from 1 April 2008 DOMESTIC 100 1 T01 Domestic single rate credit 93.500.501.801.802 393 1 24 hours 101 1 T01 Domestic single rate prepayment 510.511.720

More information

Approved Meter Sockets and Cabinets

Approved Meter Sockets and Cabinets Single Unit Residential Guide 1 PHASE, 120/240 VOLT SERVICES SERVICE CAPACITY OWNED METERING (Metering sockets and cabinets are supplied by Customer). Outdoor meter mounting height is 1730 mm ( 5 8 ) to

More information

S P E C I F I C A T I O NS

S P E C I F I C A T I O NS FOR OFFICIAL USE ONLY T FOR PUBLICATION TENDERER S COPY ORIGINAL COPY T E N D E R S P E C I F I C A T I O NS TENDER. BHEL/NR/SCT/ GGSRP BATHINDA / ELE / 659 FOR Erection, testing, commissioning, post commissioning,

More information

Ceiling Star Installation Instructions

Ceiling Star Installation Instructions Revision:1 30/03/11 Ceiling Star Before commencing installation ensure the relevant mains supply Installation should be carried out in accordance with the latest Installation should be carried out by a

More information