SOLO 1000 DRUMM-SCALE
|
|
- Marjory Hodges
- 5 years ago
- Views:
Transcription
1 SOLO 000 DRUMM-SCALE SCALE: INDICATOR: DRUMM-SCALE 7 SOLO 000 TM INSTALLATION & OPERATION electronic 30-gallon to 55-gallon drums - or 2-channel solo indicators factory calibrated NET = 525 s/n -CHANNEL NET # = 525 NET #2 = CHANNEL Version: PRO96LCD F LO Q U I P Fax: / Info@forceflow.com REF: T4\O&M\DRUMSOLO\CVRDRMSO.tcw (T00.pdf)
2 INCLUDES MODELS: ELECTRONIC DRUMM-SCALE with SOLO OR 2-CHANNEL DIGITAL INDICATOR FOR CAPACITIES: 400 lbs. (8 kg) to,000 lbs. (454 kg) FOR PLATFORM SIZES: 27-/2" x 27-/2" (699mm x 699mm) COVERING MODELS: PLATFORM 400 lb. 27-DR4DS (Metric: 27-DR2KDS 200 kg.) (36 SS Model: 27-DR4DSS, Metric 27-DR2KDSS) 600 lb. 27-DR6DS (Metric: 27-DR3KDS 300 kg) (36 SS Model: 27-DR6DSS, Metric 27-DR3KDSS) 800 lb. 27-DR8DS (Metric: 27-DR4KDS 400 kg) (36 SS Model: 27-DR8DSS, Metric 27-DR4KDSS) 000 lb. 27-DR0DS (Metric: 27-DR5KDS 500 kg) (36 SS Model: 27-DR0DSS, Metric 27-DR5KDSS) INDICATOR 000- (-Channel) (2-Channel) US & Canada, Fax: / INFO@FORCEFLOW.COM REF: T4\O&M\DRUMSOLO\MODELNO.tcw (T0A.pdf)
3 HELP HOTLINE NOTES:
4 INDEX SOLO 000 Indicator with DRUMM-SCALE SECTION S..000 YOU ARE HERE! INSTALLATION OF PLATFORM: S..0 Platform Installation Instructions S..02 Dimensioned Installation Drawing INSTALLATION OF LOAD CELL S..4 Load Cell Assembly Drawing INDICATOR INSTALLATION S CHANNEL: Indicator Wiring & Plumbing Drawing S CHANNEL: Indicator Wiring etc. S CHANNEL: Instructions: Power; Load Cell & Tare Adjust; 4-20mA S CHANNEL: Instructions: Power etc. S CHANNEL: Instructions: Set Point; Surge & Static Protection S CHANNEL: Instructions: Set Point etc. INSTALLATION CHECK LISTS S..30 Installation Check List S..305 Start-Up Check List (Portable or Fixed Tanks) S SCALE OPERATION: S.2.0 Portable Tank Scale Operation S OPTIONAL ALARM SET POINT: S CHANNEL Alarm Set Point Configuration S CHANNEL Alarm Set Point Configuration CALIBRATION: S.3.0 S.3.20 Platform Installation & Calibration Checking Scale Calibration via Water Test PARTS LIST: S.3.40 Parts List for Drumm-Scale US & Canada, Fax: REF: T4\O&M\POWRCELL.\Y42.tcw etc (Y42.pdf etc)
5 INSTALLATION DRUMM-SCALE with ELECTRONIC INDICATOR (,000 lb. or 500 kg. Capacity) DRUMM-SCALE SCALES for PORTABLE Drums INSTALLATION: (See Installation Drawings and for Drumm-Scale) Position scale platform on level surface. The hinge and load cell must be adequately supported by concrete slab or other suitable substrate. 2 Anchor hinge to ground or substrate using suitable anchors. DO NOT OPERATE SCALE UNLESS IT IS ANCHORED TO GROUND! 3 Install shear-beam load cell using 2 flat head socket screws, shim plate and threaded nuts per Drawing and Drawing Load cell arrow should point upward, load button with jam nut should face toward ground with shim plate between load cell and platform. 4 Level the platform by threading the load button in or out and locking the jam nut in place when level. DO NOT extend the load button beyond the available threads in the load cell. This will cause the improper operation of your scale. The load button is all that contacts the ground. 5 Feed load cell cable through notch in side of platform and use tab to keep cable suspended and clear of platform edge and obstructions. 6 The Load Cell is equipped with 20' of shielded cable which connects to the inside of the bottom of the indicator (see page 6). If you are imbedding conduit in your concrete pad, between your scale and indicator, we recommend -/2" ID conduit so you can fit all your load cell cables in one conduit. DO NOT run any other inductive load with your load cell cable. Wire load cell cable to indicator per indicator wiring instructions Page 9. 7 Measure the diameter of your drum and set the backstop on the platform to the drum diameter using the calibration grid. REF: WP File: O&M\DRUMWIZ\ELECDRUM.wpd (T0.pdf) QUESTIONS? Call our HELP HOTLINE W..0 S..0
6 24" 23" 22" 2" 20" 9" 8" Load Cell Anchor holes in Platform Notch in Platform (Tab) SOLO 000 NET # = 000 NET #2 = 534 F L OQ I SOLO 000 Indicator ELECTRONIC DRUMM-SCALE PLATFORM WITH LOAD CELL AND 20' CABLE EPOXY MODEL (Platform with Load Cell) U P DR4DS (DR2KDS) DR6DS (DR3KDS) DR8DS (DR4KDS) DR0DS (DR5KDS) 400 lbs (200 kg) 600 lbs (300 kg) 800 lbs (400 kg) 000 lbs (500 kg) 27 /2" (699mm) 36 SS MODEL (Platform with Load Cell) DR4DSS (DR2KDSS) DR6DSS (DR3KDSS) DR8DSS (DR4KDSS) DR0DSS (DR5KDSS) 400 lbs (200 kg) 600 lbs (300 kg) 800 lbs (400 kg) 000 lbs (500 kg) Calibration Grid Backstop Load Cell Anchor Holes in Platform 27 /2" 27 3/4" (699mm) (705mm) Load Cell Cable to Indicator INDICATOR MODEL (# OF CHANNELS) SR000- -Channel SR Channel Platform Model C L Capacity of Drum (and Diameter ) Feet of Cable (20' Std) Indicator Model (Lbs. or Kgs. ) TOP VIEW SIDE VIEW Scale Platform Mounting Bolt Sleeves Spacer END VIEW S..02 2" (5mm) 3 /2" (800mm) Arrow Facing Up Load Button & Jam Nut Shear Beam Load Cell Mounting Bolt Sleeves F LOQ U I P US & Canada, Fax: ELECTRONIC DRUMM-SCALE with SOLO 000 Indicator Drawn by: SLP Date: 06/8/98 Revised: 06/05/00 Drawing Number File: T4\O&M\DRUMSOLO\DRUMSOLO.tcw (T02.pdf) (WEB: DRUMSOLO.pdf) 8/0 Scale: NONE
7 HELP HOTLINE NOTES:
8 INDEX SOLO 000 Indicator with DRUMM-SCALE SECTION S..000 INSTALLATION OF PLATFORM: S..0 Platform Installation Instructions S..02 Dimensioned Installation Drawing YOU ARE HERE! INSTALLATION OF LOAD CELL S..4 Load Cell Assembly Drawing INDICATOR INSTALLATION S CHANNEL: Indicator Wiring & Plumbing Drawing S CHANNEL: Indicator Wiring etc. S CHANNEL: Instructions: Power; Load Cell & Tare Adjust; 4-20mA S CHANNEL: Instructions: Power etc. S CHANNEL: Instructions: Set Point; Surge & Static Protection S CHANNEL: Instructions: Set Point etc. INSTALLATION CHECK LISTS S..30 Installation Check List S..305 Start-Up Check List (Portable or Fixed Tanks) S SCALE OPERATION: S.2.0 Portable Tank Scale Operation OPTIONAL ALARM SET POINT: S CHANNEL Alarm Set Point Configuration S CHANNEL Alarm Set Point Configuration S CALIBRATION: S.3.0 S.3.20 Platform Installation & Calibration Checking Scale Calibration via Water Test PARTS LIST: S.3.40 Parts List for Drumm-Scale US & Canada, Fax: REF: T4\O&M\POWRCELL.\Y42.tcw etc (Y42.pdf etc)
9 Mounting Bolts Drumm-Scale Platform Frame Spacer Strain Relief Arrow facing up Cable Jam Nut Load Button S..4 W..4 Mounting Bolt Sleeves US & Canada, Fax: DRUMM-SCALE Load Cell Mounting Drawing Drawn by: SLP Date: 09/0/95 Revised: 05/20/97 Drawing Number File: T4\O&M\DRUMWIZ\DRDRUMLC.tcw (T03.pdf) Scale: NONE
10 INDEX SOLO 000 Indicator with DRUMM-SCALE SECTION S..000 INSTALLATION OF PLATFORM: S..0 Platform Installation Instructions S..02 Dimensioned Installation Drawing INSTALLATION OF LOAD CELL S..4 Load Cell Assembly Drawing YOU ARE HERE! INDICATOR INSTALLATION S CHANNEL: Indicator Wiring & Plumbing Drawing S CHANNEL: Indicator Wiring etc. S CHANNEL: Instructions: Power; Load Cell & Tare Adjust; 4-20mA S CHANNEL: Instructions: Power etc. S CHANNEL: Instructions: Set Point; Surge & Static Protection S CHANNEL: Instructions: Set Point etc. INSTALLATION CHECK LISTS S..30 Installation Check List S..305 Start-Up Check List (Portable or Fixed Tanks) S SCALE OPERATION: S.2.0 Portable Tank Scale Operation OPTIONAL ALARM SET POINT: S CHANNEL Alarm Set Point Configuration S CHANNEL Alarm Set Point Configuration S CALIBRATION: S.3.0 S.3.20 Platform Installation & Calibration Checking Scale Calibration via Water Test PARTS LIST: S.3.40 Parts List for Drumm-Scale US & Canada, Fax: REF: T4\O&M\POWRCELL.\Y42.tcw etc (Y42.pdf etc)
11 -CHANNEL INDICATOR ONLY SOLO 000 Box (bottom view) 7 /2" (90mm) Box (attaches to wall) 4 Wall Mounting Screw Holes Tare Adjust Knob Box 7/2" (90mm) + G C NOTE: Mount Indicator at "eye level" with the mounting fixtures provided. Cable Conduit Fitting 0 VOLT AC Power Hook-Up + G VOLT AC Power Hook-Up Plastic Washer /4" Cord Connector Connector Sleeve Rubber Grommet 2 Load Cell Use for: Load Cell Cable J SW (ZERO) DN UP (Dip Switches) SW4 SW2 SW3 J7 C 2 4 Set Point J R G w B S S W #2 #4 Red Green White Black Shield STEP : Slip conduit fitting base over conduit STEP 3: Attach to conduit/cable connector fitting on box STEP 2: Slide conduit connector into conduit DN UP mA Box Cover (swings down) S..20 -Channel 4 Slotted Pan Head Screws. (Tighten screws evenly to get uniform seal on cover gasket) /2" Conduit Connector Use for: Power 4-20 MA Signal Alarm -CHANNEL INDICATOR ONLY US & Canada, Fax: File: T4\O&M\ASOMSTR\SOLOIND.tcw (D0-.pdf) SOLO INDICATOR WIRING AND PLUMBING INSTRUCTIONS --SINGLE CHANNEL-- Drawn by: SLP Date: 06/30/98 Revised: 0/6/0 Scale: NONE Drawing Number 30046
12 7/2" (90mm) VOLT AC Power Hook-Up Box (attaches to wall) 7 /2" (90mm) 0 VOLT AC Power Hook-Up SW Box Cover (swings down) R G w B S R G w B S Red Green White Black Shield Red Green White Black Shield 4 Wall Mounting Screw Holes US & Canada, Fax: File: T4\O&M\ASOLMSTR\SOLO2IND.tcw (D0-2.pdf) NOTE: Mount Indicator at "eye level" with the mounting fixtures provided. STEP : Slip conduit fitting base over conduit 4 Slotted Pan Head Screws. (Tighten screws evenly to get uniform seal on cover gasket) SOLO 000 Box (bottom view) /2" Conduit Connector Use for: Power 4-20 MA Signals Alarms STEP 2: Slide conduit connector into conduit Plastic Washer STEP 3: Attach to conduit/cable connector fitting on box SOLO INDICATOR WIRING AND PLUMBING INSTRUCTIONS --DUAL CHANNEL-- Cable Tare Adjust Knobs Box /4" Cord Connector Use for: Load Cell Cable Drawn by: SLP Date: 03/2/0 Revised: Scale: NONE Conduit Fitting Rubber Grommet Connector Sleeve SW4 (Dip Switches) S Channel ON OFF 3 FLOQUIP 2-CHANNEL INDICATOR ONLY CHANNEL INDICATOR ONLY Drawing Number SCALE 2 SCALE TARE 2 2 TARE LOAD CELL 2 RELAYS NC 2C NO NC C NO + G + + G C LOAD CELL SW2 SW3 POWER 4-20mA G
13 -CHANNEL INDICATOR ONLY SOLO INDICATOR INSTALLATION & WIRING ALWAYS SHUT OFF MAIN POWER, AS WELL AS POWER TO ANY AUXILIARY EQUIPMENT THAT WILL BE INSTALLED IN THIS UNIT, BEFORE OPENING FRONT OF CASE!! All connectors have screw-type terminals to assist in connecting wires. Remove the connector from the board before attaching wires. POWER HOOK-UP TURN OFF MAIN POWER BEFORE CONNECTING!! Use a clean 0 Volt AC power line, connected directly to the main power panel at the facility. DO NOT connect any other inductive loads, relays, etc. to this power line! Resulting power surges can damage the electronics!!! Use far left bottom port and connect per following: (NOTE: Use /2" conduit connector) 0 Volt AC 230 Volt AC POWER IN POWER IN Hot (+) Ground (G) Hot (+) Neutral (N) Ground (G) Hot (+) 2 LOAD CELL & TARE ADJUST KNOB CONNECTION DO NOT CUT LOAD CELL CABLE!! This may void your warranty!! Your SOLO 000 Indicator is shipped with the load cell connected and ready to power up. Should you need to run the load cell cable through conduit, first unplug the connector from the board, then disconnect wires, and remove by unscrewing cord connector. When routing load cell cable into box, use /2" cord connector. DO NOT run load cell cable with any other inductive load or power cables!! Connect load cell wires per following: (NOTE: Use /2" cord connector) BE CERTAIN TARE ADJUST KNOB WIRES ARE CONNECTED. Scale R G W B S Load Cell Cable Red Green White Black Braided Wire J Connector R G W B S Tare Adjust Knob Red Green Black Description + Excitation + Signal - Signal - Excitation Shield MA SIGNAL Your 4-20 MA signal is internally powered for up to 900 OHMS. DO NOT use external loop power. (NOTE: Use /2" conduit connector). DO NOT run 4-20 MA signals with any other power lines, which carry an inductive load.. J5 Connector Description Scale _ Signal - Signal S CHANNEL INDICATOR ONLY REF: T4\O&M\ASOMSTR\INSOLOA.tcw (D02-.pdf) QUESTIONS? Help Hotline:
14 2-CHANNEL INDICATOR ONLY SOLO INDICATOR INSTALLATION & WIRING ALWAYS SHUT OFF MAIN POWER, AS WELL AS POWER TO ANY AUXILIARY EQUIPMENT THAT WILL BE INSTALLED IN THIS UNIT, BEFORE OPENING FRONT OF CASE!! All connectors have screw-type terminals to assist in connecting wires. Remove the connector from the board before attaching wires. POWER HOOK-UP TURN OFF MAIN POWER BEFORE CONNECTING!! Use a clean 0 Volt AC power line, connected directly to the main power panel at the facility. DO NOT connect any other inductive loads, relays, etc. to this power line! Resulting power surges can damage the electronics!!! Use far left bottom port and connect per following: (NOTE: Use /2" conduit connector) 0 Volt AC 230 Volt AC POWER IN POWER IN Hot (+) Ground (G) Hot (+) Neutral (N) Ground (G) Hot (+) 2 LOAD CELL CONNECTIONS DO NOT CUT LOAD CELL CABLE!! This may void your warranty!! Your SOLO 000 Indicator is shipped with the load cell connected and ready to power up. Should you need to run the load cell cable through conduit, first unplug the connector from the board, then disconnect wires, and remove by unscrewing cord connector. When routing load cell cable into box, use /2" cord connector. DO NOT run load cell cable with any other inductive load or power cables!! Connect load cell wires per following: (NOTE: Use /2" cord connector) PLUG-IN CONNECTOR R G W B S Load Cell Cable Red Green White Black Braided Wire J3 & J4 Connector + X + S - S - X SH Description + Excitation + Signal - Signal - Excitation Shield MA SIGNAL 20.00mA = (LBS or KGS) Your 4-20 MA signal is internally powered. DO NOT use external loop power. NOTE: Use /2" conduit connector. DO NOT run 4-20 MA signals with any other power lines, which carry an inductive load. Scale 2 Scale _ + _ + Connector Description _ + _ + - Signal + Signal - Signal + Signal S REF: T4\O&M\ASOLMSTR\INSO2CHA.tcw (DO2-2.pdf) QUESTIONS? Help Hotline: CHANNEL INDICATOR ONLY
15 -CHANNEL INDICATOR ONLY SOLO INDICATOR INSTALLATION & WIRING cont... 4 SET POINTS The SOLO 000 features two (2) adjustable set points that can be used for alarm or control applications. The signals are TTL Digital Outputs and can be used to activate an external relay or be wired directly into a PLC that accepts this type of input. The set point outputs are "sinking" transistors that drop to ground when the set point level is reached. The signal is 5 VDC at 300mA. To configure the set points, see Set Point Configuration Instructions in Chapter IV. SET POINT : SET POINT 2: Above Set Point = 5 VDC Below Set Point = 0 VDC Above Set Point = 5 VDC Below Set Point = 0 VDC SET POINT TERMINALS C NOT USED 2 PC BOARD C 2 DESCRIPTION Common Set Point Ground Set Point 2 Ground NOT USED LIGHTNING ~ SURGE PROTECTION Be sure that all power coming into the facility is sufficiently protected for transient lightning strikes and power surges. Improper protection may void your warranty. STATIC ELECTRICITY PROTECTION CAUTION should be observed whenever box is open to avoid damage or memory loss by static electricity. DO NOT touch any of the circuit board, other than the intended contact noted in these instructions. Carpets, especially can build up static electricity. F LO Q U I P S CHANNEL INDICATOR ONLY QUESTIONS? Help Hotline: REF: T4\O&M\SOLO\INSOL0B.tcw (D03-.pdf)
16 2-CHANNEL INDICATOR ONLY SOLO INDICATOR INSTALLATION & WIRING cont... 4 LEVEL ALARMS (OPTIONAL) The SOLO 000 features two (2) optional level alarms that can be used for alarm or control applications. The relays are Form C, Dry Contacts rated at 2A at 30 VDC, 0.5A at 20 VAC. SET POINT TERMINALS PC BOARD DESCRIPTION NC 2C NO NC C NO NC 2C NO NC C NO #2 Normally Closed #2 Common #2 Normally Open # Normally Closed # Common # Normally Open LIGHTNING ~ SURGE PROTECTION Be sure that all power coming into the facility is sufficiently protected for transient lightning strikes and power surges. Improper protection may void your warranty. STATIC ELECTRICITY PROTECTION CAUTION should be observed whenever box is open to avoid damage or memory loss by static electricity. DO NOT touch any of the circuit board, other than the intended contact noted in these instructions. Carpets, especially can build up static electricity. F L OQ U I P S CHANNEL INDICATOR ONLY REF: T4: O&M\ASOLMSTR\INSO2CHB.tcw (D03-2.pdf) QUESTIONS? Help Hotline:
17 INDEX SOLO 000 Indicator with DRUMM-SCALE SECTION S..000 INSTALLATION OF PLATFORM: S..0 Platform Installation Instructions S..02 Dimensioned Installation Drawing INSTALLATION OF LOAD CELL S..4 Load Cell Assembly Drawing INDICATOR INSTALLATION S CHANNEL: Indicator Wiring & Plumbing Drawing S CHANNEL: Indicator Wiring etc. S CHANNEL: Instructions: Power; Load Cell & Tare Adjust; 4-20mA S CHANNEL: Instructions: Power etc. S CHANNEL: Instructions: Set Point; Surge & Static Protection S CHANNEL: Instructions: Set Point etc. YOU ARE HERE! INSTALLATION CHECK LISTS S..30 Installation Check List S..305 Start-Up Check List (Portable or Fixed Tanks) S SCALE OPERATION: S.2.0 Portable Tank Scale Operation OPTIONAL ALARM SET POINT: S CHANNEL Alarm Set Point Configuration S CHANNEL Alarm Set Point Configuration S CALIBRATION: S.3.0 S.3.20 Platform Installation & Calibration Checking Scale Calibration via Water Test PARTS LIST: S.3.40 Parts List for Drumm-Scale US & Canada, Fax: REF: T4\O&M\POWRCELL.\Y42.tcw etc (Y42.pdf etc)
18 INSTALLATION CHECK-OFF LIST INSTALL SCALE PLATFORM & LOAD CELL (Section.3) - Route load cell cable to indicator mounting location, per instructions. 2 MOUNT INDICATOR (Section.20) - Mount at proper location, at eye level 3 WIRE INDICATOR - TURN OFF ALL POWER BEFORE WIRING! (Section.20) - Connect dedicated clean 0 volt AC power line through /2" conduit connector. - Connect Load Cell cable through /4" cord connector. - Connect 4-20 MA signal through /2" conduit connector. - Connect relays through /2" conduit connector (same connector as 4-20 ma) 4 SEAL INDICATOR ENCLOSURE TO MAINTAIN 4X RATING!!! (Section.20) - Tighten all four (4) door screws to maintain NEMA 4X seal on box. - Double check all cord connectors for tight seal. - Double check all /2" conduit connectors for tight seal. REF: WP File: O&M\SOLOMSTR\ INSTSOLO.wpd (O02.pdf) S..30
19 START-UP CHECK-OFF LIST with SOLO INDICATOR PORTABLE TANK APPLICATIONS TANKS ARE CHANGED (TANK AND CHEMICAL REPLACED) POWER-UP: The value will be the tare weight of your scale platform. 2 Apply pressure to platform to see if indicator responds to changes in weight. 3 Verify the platform calibration on the following page. 4 Load tank(s) onto scale. Use tare adjustment knob to "tare out" container weight. FIXED TANK APPLICATIONS TANKS ARE NOT CHANGED (EMPTIED AND REFILLED IN PLACE) POWER-UP: The value will be the tare weight of your scale platform. 2 Apply pressure to platform to see if indicator responds to changes in weight. 3 With EMPTY tank mounted on the platform, turn tare adjust knob until scale indicator reads zero. 4 Fill tank. S..305 REF: T4\O&M\ASOMSTR\STARTUP.tcw (S08.pdf)
20 HELP HOTLINE NOTES:
21 INDEX SOLO 000 Indicator with DRUMM-SCALE SECTION S..000 INSTALLATION OF PLATFORM: S..0 Platform Installation Instructions S..02 Dimensioned Installation Drawing INSTALLATION OF LOAD CELL S..4 Load Cell Assembly Drawing INSTALLATION CHECK LISTS S..30 Installation Check List S..305 Start-Up Check List (Portable or Fixed Tanks) S SCALE OPERATION: S.2.0 Portable Tank Scale Operation YOU ARE HERE! INDICATOR INSTALLATION S CHANNEL: Indicator Wiring & Plumbing Drawing S CHANNEL: Indicator Wiring etc. S CHANNEL: Instructions: Power; Load Cell & Tare Adjust; 4-20mA S CHANNEL: Instructions: Power etc. S CHANNEL: Instructions: Set Point; Surge & Static Protection S CHANNEL: Instructions: Set Point etc. OPTIONAL ALARM SET POINT: S CHANNEL Alarm Set Point Configuration S CHANNEL Alarm Set Point Configuration S CALIBRATION: S.3.0 S.3.20 Platform Installation & Calibration Checking Scale Calibration via Water Test PARTS LIST: S.3.40 Parts List for Drumm-Scale US & Canada, Fax: REF: T4\O&M\POWRCELL.\Y42.tcw etc (Y42.pdf etc)
22 OPERATION If you have any questions regarding the installation, operation or maintenance of your scale, please DO NOT HESITATE TO CALL OUR HELP HOTLINE ; us at or Fax us "PORTABLE" TANK APPLICATIONS "FIXED" TANK APPLICATIONS "PORTABLE" means: Empty tank is REPLACED. "FIXED" means: Empty tank is REFILLED. LOAD CONTAINER Load a FULL container on scale platform. NOTE: To calibrate a DRUMM-SCALE, CYLINDER-SCALE, TOTE BIN SCALE or CARBOY-SCALE: Make sure the tank is resting against the backstop. If scale weighs HEAVY...move backstop forward. If scale weighs LIGHT...move backstop back. PROCESS CONNECTIONS Make all necessary process connections to container or tank. Assure that all connections are FLEXIBLE, so as not to restrain the vessel from freely resting on the scale and platform movement is not restrained. DETERMINE TARE To determine tare weight: ) Check container to see if the tare weight is marked on it (ie stamped on chine or top of cylinder). 2) On containers and tanks that are not marked, begin by zeroing the scale. Place an empty container and any applicable process connections. The value dsiplayed is the tare weight. Record this weight in a visible location for future reference....prior TO FILLING TANK: CENTER TANK Load a FULL container on scale platform. CHEM-SCALE or BULK TANK (permanent tank) applications only: CHEM-SCALE: Make certain that the tank is centered on platform. BULK TANKS: Make certain saddles are equal distance from tank centerline. PROCESS CONNECTIONS Make all necessary process connections to container or tank. Assure that all connections are FLEXIBLE, so as not to restrain the vessel from freely resting on the scale and platform movement is not restrained. TARE ADJUSTMENT WITH NO CHEMICAL IN TANK... Rotate the tare adjustment knob until it reads ZERO. FILL TANK Fill tank. Indicator should now read only weight of chemical. TARE ADJUSTMENT Rotate the tare adjustment knob until the display indicates the net contents of the container (the tare adjustment is located on face of the CENTURY dial, or the side of the SOLO 000). NOTE: When loading a PARTIALLY full container, start by zeroing the scale with the tare adjust knob. Then place the container on the scale and make process connections. Use the tare adjustment to subtract the tare weight amount from the displayed amount. QUESTIONS? Help Hotline: S.2.0 C.2.0 X US & Canada, Fax: File: T4\O&M\ASOMSTR\OPERATN.tcw (D04.pdf)
23 INDEX SOLO 000 Indicator with CHEM-SCALE SECTION S..000 INSTALLATION OF PLATFORM: S..0 Installation Steps thru 3 S..02 Installation Steps 4 thru 6 S..04 Dimensioned Drawing - Chem Scale S..05 Dimensioned Ddrawing - Tote Bin Scale S..06 Tote Bin Operating Instructions SUPPLY CONNECTIONS S..3 Supply Connections Instructions LOAD CELL INSTALLATION S..4 Load Cell Technical Data INDICATOR INSTALLATION S CHANNEL: Indicator Wiring & Plumbing Drawing S CHANNEL: Indicator Wiring etc. S CHANNEL: Instructions: Power; Load Cell & Tare Adjust; 4-20mA S CHANNEL: Instructions: Power etc. S CHANNEL: Instructions: Set Point; Surge & Static Protection S CHANNEL: Instructions: Set Point etc. INSTALLATION CHECK LISTS S..30 Installation Check List S..305 Start-Up Check List (Portable or Fixed Tanks) S SCALE OPERATION: S.2.0 Portable Tank Scale Operation YOU ARE HERE! OPTIONAL ALARM SET POINT: S CHANNEL Alarm Set Point Configuration S CHANNEL Alarm Set Point Configuration S PARTS LIST: S.3.40 Parts List for Drumm-Scale US & Canada, Fax: REF: T4\O&M\INDEX.\Y4.tcw etc (Y4.pdf etc)
24 -CHANNEL INDICATOR ONLY ALARM SET POINT CONFIGURATION CAUTION! ALWAYS USE EXTREME CARE WHEN WORKING NEAR ENERGIZED CIRCUITS The SOLO 000 features two (2) adjustable set points that can be used for alarm or control applications. The signals are TTL Digital Outputs and can be used to activate an external relay or be wired directly into a PLC that accepts this type of input. The set point outputs are "sinking" transistors that drop to ground when the set point level is reached. The signal is 5 V DC at 300mA. SET POINT : SET POINT 2: Weight BELOW Set Point Level = 0 V DC Weight ABOVE Set Point Level = 5 V DC Weight BELOW Set Point 2 Level = 0 V DC Weight ABOVE Set Point 2 Level = 5 V DC TO CONFIGURE SET POINTS SET POINT : ) Apply weight (the actual amount of desired set point level) on scale. 2) Close and open Switch #SW4-3 3) Remove weight. SET POINT 2: ) Apply weight (the actual amount of desired set point level) on scale. 2) Close and open Switch #SW4-2 3) Remove weight. To "INVERT" Relay Operations, connect jumper pins on "JP-3". Inverted Relay Operation will actuate the alarm relay contacts in a NON-ALARM condition. When an ALARM condition occurs, the alarm relay contacts are deactuated. This feature allows configuration of FAIR SAFE alarm relay contacts. SET POINT (Dip Switches) SW4-3 (OPEN) ON (CLOSE) SET POINT 2 (Dip Switches) SW4-2 (OPEN) J (ZERO) DN UP (Dip Switches) SW SW SW2 J7 (OPEN) ON (CLOSE) SW3 C 2 J R G w B S S #2 #4 Red Green White Black Shield ON (CLOSE) DN UP W S CHANNEL INDICATOR ONLY REF: T4\O&M\ASOMSTR\ALARMSOL.tcw (D05-.pdf) QUESTIONS? Help Hotline:
25 2-CHANNEL INDICATOR ONLY ALARM SET POINT CONFIGURATION CAUTION! ALWAYS USE EXTREME CARE WHEN WORKING NEAR ENERGIZED CIRCUITS If your SOLO includes the optional Level Alarm Relay(s), the following instructions establish setpoint values. Relays are Form C Dry Contact, rated 2A@30 VDC, 20VAC. SET ALARM LEVEL STEP : Turn SWITCH # on SW4 "OFF". STEP 2: For SCALE #, turn Switch #4 on SW4 "ON". For SCALE #2, turn Switch #5 on SW4 "ON". STEP 3: Use SW2 to count DOWN or SW3 to count UP to desired setpoint level. The value displayed on the screen is the weight at which the alarm will trigger. STEP 4: Turn Switch #4 or #5 on SW4 "OFF". STEP 5: Turn Switch # on SW4 "ON". To "INVERT" Relay Operations, turn switches # and #7 "ON". Display will read: INVERT RELAY? YES *NO Use switches SW2 or SW3 to toggle * (asterisk). Turn switch #7 "OFF" to resume operation. Inverted Relay Operation will actuate the alarm relay contacts in a NON-ALARM condition. When an ALARM condition occurs, the alarm relay contacts are de-actuated. This feature allows configuration of FAIR SAFE alarm relay contacts. COUNT DOWN OR UP SCALE STEP 3 TO DESIRED SET POINT (DOWN) (UP) SW2 SW3 STEP 2 STEP SCALE 2 STEP 2 STEP STEP 3 STEP 4 STEP 5 STEP 4 STEP COUNT DOWN OR UP TO DESIRED SET POINT (DOWN) (UP) SW2 SW (DOWN) POWER 4-20mA G + (UP) SW2 SW3 ON SW4 RS485 RS232 OFF RELAYS NC 2C NO NC C NO 2 TARE 2 SW TARE SCALE 2 LOAD CELL SCALE LOAD CELL R G w B S R G w B S RED GREEN WHITE BLACK SHIELD RED GREEN WHITE BLACK SHIELD S CHANNEL INDICATOR ONLY QUESTIONS? Help Hotline: REF: T4\O&M\ASOMSTR\ALARMSO2.tcw (D05-2.pdf) 3/05/02 CHECKED BY: BD 03/05/02
26 INDEX SOLO 000 Indicator with DRUMM-SCALE SECTION S..000 INSTALLATION OF PLATFORM: S..0 Platform Installation Instructions S..02 Dimensioned Installation Drawing INSTALLATION OF LOAD CELL S..4 Load Cell Assembly Drawing INDICATOR INSTALLATION S CHANNEL: Indicator Wiring & Plumbing Drawing S CHANNEL: Indicator Wiring etc. S CHANNEL: Instructions: Power; Load Cell & Tare Adjust; 4-20mA S CHANNEL: Instructions: Power etc. S CHANNEL: Instructions: Set Point; Surge & Static Protection S CHANNEL: Instructions: Set Point etc. INSTALLATION CHECK LISTS S..30 Installation Check List S..305 Start-Up Check List (Portable or Fixed Tanks) S SCALE OPERATION: S.2.0 Portable Tank Scale Operation OPTIONAL ALARM SET POINT: S CHANNEL Alarm Set Point Configuration S CHANNEL Alarm Set Point Configuration S YOU ARE HERE! CALIBRATION: S.3.0 S.3.20 Platform Installation & Calibration Checking Scale Calibration via Water Test PARTS LIST: S.3.40 Parts List for Drumm-Scale US & Canada, Fax: REF: T4\O&M\POWRCELL.\Y42.tcw etc (Y42.pdf etc)
27 NOTE: Allign REAR of backstop equal to Drum base diameter. (Example 22" base diameter) Corner Notch to hold Cable Calibration Grid (C) Load Cell Mounting Hole Cable Backstop Nuts (B) (A) Drum outer diameter at base (Example: 22" base diameter) S.3.0 F LOQ U I P US & Canada, Fax: DRUMM-SCALE Installation & Calibration Drawn by: SLP Date: 04/23/90 Revised: 0/09/98 Drawing Number File: T4\O&M\DRUMSOLO\DRUMGRID.tcw (T06.pdf) Scale: NONE
28 CHECKING SCALE CALIBRATION via the "WATER TEST" on VERTICAL ROUND TANKS TO DETERMINE TANK MEASUREMENTS: To calculate volume, you need to make 2 basic measurements with a tape measure: TANK "RADIUS" and WATER "HEIGHT". STEP : With NO WATER in the tank, measure the inside diameter (I.D.) of the tank to the nearest /6" of an inch. Take care when measuring so that your tape measure is "level" and you are measuring across the MIDDLE of the tank. STEP 2: ZERO scale indicator, then fill the tank with water approximately 80% full. Step 2: Zero scale indicator, then fill 80% full with water. Step : Measure tank inside diameter. STEP 3: Put tape measure down through the water and measure the water level to the nearest /6 of an inch. This value represents your "HEIGHT". Step 3: Measure water height. 3 TO DETERMINE VOLUME: The volume (in gallons) of your container can be determined by this simple formula: FORMULA: (3.46 x Drum Radius x Drum Radius x Water Height) divided by 23 = Gallons Example: (3.46 X.28" x.28" x 35.87") divided by 23 = Gallons 3.46 = PI (constant) 23 = Cubic inches in gallon (constant) Drum radius is half of drum inner diameter. Example: 22-9/6" (22.562") divided by 2 =.28" Drum Radius Water Height = 35-3/6 (35.870) TO DETERMINE WEIGHT: Once the volume is determined, multiply the total gallons times the weight per gallon of water (which is 8.34 lbs. per gallon). The weight of water is the same universally. FORMULA: Gallons x Lbs. per gallon = Total lbs. Example: x 8.34 lbs/gallon = lbs. Total = Gallons as determined above *8.34 = Weight of water (lbs. per gallon) IMPORTANT NOTE: Minimum test sample: 20 gallons All measurements should be made to + or - /6". All calculations should be made to 3 decimal places (i.e ) DO NOT GIVE CREDENCE TO "GALLON" MARKINGS ON TANK!! THEY PROBABLY ARE NOT ACCURATE!! S.3.20 W Fax: REF: T4\O&M\DRMHYD\DRMCAPCT.tcw (N05.pdf) 0/24/02
29 HELP HOTLINE NOTES:
30 INDEX SOLO 000 Indicator with DRUMM-SCALE SECTION S..000 INSTALLATION OF PLATFORM: S..0 Platform Installation Instructions S..02 Dimensioned Installation Drawing INSTALLATION OF LOAD CELL S..4 Load Cell Assembly Drawing INDICATOR INSTALLATION S CHANNEL: Indicator Wiring & Plumbing Drawing S CHANNEL: Indicator Wiring etc. S CHANNEL: Instructions: Power; Load Cell & Tare Adjust; 4-20mA S CHANNEL: Instructions: Power etc. S CHANNEL: Instructions: Set Point; Surge & Static Protection S CHANNEL: Instructions: Set Point etc. INSTALLATION CHECK LISTS S..30 Installation Check List S..305 Start-Up Check List (Portable or Fixed Tanks) S SCALE OPERATION: S.2.0 Portable Tank Scale Operation OPTIONAL ALARM SET POINT: S CHANNEL Alarm Set Point Configuration S CHANNEL Alarm Set Point Configuration S CALIBRATION: S.3.0 S.3.20 Platform Installation & Calibration Checking Scale Calibration via Water Test YOU ARE HERE! PARTS LIST: S.3.40 Parts List for Drumm-Scale US & Canada, Fax: REF: T4\O&M\POWRCELL.\Y42.tcw etc (Y42.pdf etc)
31 Electronic CHEM-SCALE or DRUMM-SCALE -- PARTS & ACCESSORIES 8 WIZARD 4000 SCALE 50 LBS SCALE LBS WMA420 8 W5ASP 2 a or b: Chem-Scale or Tote Bin Scale Platform: 30" x 30" Chem-Scale Platform 40" x 40" Chem-Scale Platform 50" x 50" Chem-Scale Platform 60" x 60" Chem-Scale Platform 72" x 72" Chem-Scale Platform c: Drumm-Scale Frame: 27-/2" x 27-/2" Drumm-Scale Platform a) Backstop ( for Chem Tote Bins) b) Hold Down Clips (4 for Chem Tanks) c) Backstop ( for Drums) Cable Electronic WIZARD Indicator: Wizard (-Channel) Wizard (2-Channel) Wizard (3-Channel) Wizard (4-Channel) Electronic SOLO Indicator: Solo 000 Single Channel Solo Dual Channel S5ASP 9 SERIAL PORT MOTHERBOARD (includes 4-20mA Output) 3 Load Cell with Cable: (Consult Factory on which load cell fits your application) 4 J0 JUNCTION BOX (to extend cable beyoond the standard length) J40 SUMMING BOX (to sum multiple scales or for high accuracy applications) 8 9 2a Accessories for WIZARD: W5ASP (level alarm) WMA420 (4-20mA Output) WRS232/WRS485 (Serial Port) WMB4000 (Motherboard Replacement) Accessories for SOLO: S5ASP (level alarm) SMB000 (Motherboard Replacement (includes 4-20mA) NET # 50 LBS 3 TOTE BIN SCALE 2b a 2 7 CHEM-SCALE 2c b c S.3.40 W DRUMM-SCALE US & Canada, Fax: Drawn by: SLP Drawing Number ELECTRONIC CHEM-SCALE or DRUMM-SCALE Date: 0/0/89 PARTS LIST for Tanks, Tote Bins or Drums Revised: 03/5/ File: T4\DRAWINGS\PARTCHDM.tcw (T07.pdf) 0/24/02 Scale: NONE
SOLO CARBOY-SCALE TM INSTALLATION & OPERATION 1-CHANNEL 2-CHANNEL NET = 175 SOLO 1000 SOLO NET #1 = 175 NET #2 = 225
SOLO 000 CARBOY-SCALE SCALE: INDICATOR: CARBOY-SCALE TM SOLO 7000 electronic 5-gallon to 30-gallon carboys with SOLO 000 indicator (-Channel or 2-Channel) INSTALLATION & OPERATION factory calibrated s/n
More informationkg kg FORCE FLOW Fax:
kg kg CENTURY All CYLINDERS INDICATOR: SCALE: CENTURY CHLOR-SCALE 150, AMMONIA-SCALE LIQUEFIED GAS & GAS CABINET SCALES Factory Calibrated S/N HYDRAULIC CYLINDER SCALE INSTALLATION & OPERATION SLOTTED
More informationINSTALLATION & OPERATION
CITY/ST: EQUIP: FACTORY CALIBRATED S/N INSTALLATION & OPERATION HYDRAULIC CARBOY-SCALE For Carboys & Drums 8" to 24" in Dia. 1-800-893-6723 Fax: 925-686-6713 www.forceflow.com / Info@forceflow.com REF:
More information1' to 10' deep and 1' to 25' deep
ULTRASONIC ECHO-SCALE TM SCALE: INDICATOR: ECHO-SCALE TM NONE PROVIDED electronic sensors for vessels 1' to 10' deep and 1' to 25' deep INSTALLATION & OPERATION s/n 1-800-893-6723 Fax: 925-686-6713 www.forceflow.com
More informationPROVEX Installation Guide. Version 1.0
Version 1.0 INTRODUCTION The scale must not be loaded beyond its capacity. Do not select a site where overweight load would have to maneuver to avoid crossing the platform. Avoid areas where the scale
More informationGTFM IV. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5010 Revised: June 26, 2008
Computer Weld Technology, Inc. 10702 Old Bammel N Houston Rd. Houston, TX 77086 Phone: (713) 462-2118 Fax: (713) 462-2503 Email: cwt@cweldtech.com GTFM IV Gas Turbine Flow Monitor Operation / Installation
More informationaccqpulse Velocity Profiler Sensor Installation Guide
accqpulse Velocity Profiler Sensor Installation Guide Instruction Sheet #69-7403-012 Released May 2016 Overview This instruction guide is for the installation of the accqpulse shallow water and deep water
More informationJBI Docupunch P33 Automatic Punch
JBI Docupunch P33 Automatic Punch Instruction Manual Provided By http://www.mybinding.com http://www.mybindingblog.com TABLE OF CONTENTS SECTION I: INSTALLATION & TESTING: 1) Uncrating, Inspection & removal
More informationUser s Guide. EZ-Bar Livestock Scale WEIGH BARS AND DIGITAL INDICATOR. WB-40 Weigh Bars TS-700 WB Digital Indicator. Guide version 1.
accurate around the world s i n c e 1 8 9 7 User s Guide EZ-Bar Livestock Scale WEIGH BARS AND DIGITAL INDICATOR WB-40 Weigh Bars TS-700 WB Digital Indicator Guide version 1.3 USER S GUIDE Table of Contents
More informationElectric Actuator Instructions
BAC IOM Electric Actuator Instructions E024, E025, E026, E029 & E030 TABLE OF CONTENTS Electric Actuator Specifications...2 Overview...3 Actuator Wiring Diagrams...4 VMS-35 Specifications and Wiring Diagram...5
More informationCrane Systems GREER COMPANY. LALT 1151L System for Lattice Cranes. Installation and Calibration Manual. 1 of 39
LALT 1151L System for Lattice Cranes Installation and Calibration Manual 1 of 39 This manual is designed to guide the fully trained and experienced crane operator in the correct installation and calibration
More informationELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS
HVAC/BAC ELECTRIC IOM ELECTRIC ACTUATOR E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS Electric Actuator Specifications... 2 Overview... 3 Actuator
More informationTitan Series Portable Vehicle Scale
FAIRBANKS s c a l e FAIRBANKS s c a l e Installation Manual Titan Series Portable Vehicle Scale 00 by Fairbanks Scales Inc. All rights reserved 0 Issue # 0/0 Amendment Record Titan Series Portable Vehicle
More informationELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS
ELECTRIC ACTUATOR E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS 94OE IOM Electric Actuator Specifications...2 Overview...3 Actuator Wiring Diagrams...4
More informationSignet Pressure Transmitter
Signet 80 Pressure 80.090 80.090 Rev. J 0/ English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Installation.
More informationDiamondback Truck Scale
Installation Manual Diamondback Truck Scale Portable Vehicle Scale 8560 PV Series 2007-2018 by Thurman Scale Inc. All rights reserved 51162 Revision 7 03/18 Disclaimer Every effort has been made to provide
More informationJEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market
1 888-323-8755 www.nwlifts.com JEEVES Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market This manual will cover the installation procedure step-by-step. The installation of this dumbwaiter
More informationCENTRIFLOW METER and ELECTRONICS WIRING and INSTALLATION MANUAL REV 01/16 ORIGINAL LANGUAGE Copyright 2016 Eastern Instrument Laboratories, Inc. All Rights Reserved. TABLE OF CONTENTS SAFETY Safe Operation...
More information348002K/348012K Manifold Block Style Service Manual 12/2000
348002K/348012K Manifold Block Style Service Manual 12/2000 Service Manual 348002K/348012K Manifold Block Style Recovery/Recycling/Recharging Unit For R-12 or R-134a Only TABLE OF CONTENTS: Theory of Operation
More informationF-2000 MODEL RT INSTRUCTION MANUAL. Blue-White. Industries, Ltd.
F-2000 MODEL RT INSTRUCTION MANUAL Blue-White Industries, Ltd. R PT Sarana Prima Enguna Jl.Gunung Sahari Raya 84 C - Jakarta 10610 Phone: 021-420-0045 Fax: 021-420-0483 E mail: info@spe.co.id Website:
More informationInstallation Instructions Table of Contents
Installation Instructions Table of Contents Pre- Installation of Garage Storage Lift 2 Layout the Garage Storage Lift 3 Installing the strut Channels 3 Install the Drive Assembly 5 Install the Drive Shaft
More informationSignet Pressure Transmitter
Signet 8450 Pressure English 8450.090 8450.090 Rev. G /06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents
More informationCarbon Monoxide Transmitter
Introduction The CO Transmitter uses an electrochemical sensor to monitor the CO level and outputs a 4-20 ma signal. The standard product features a 2- wire loop-powered output. Optionally, the device
More informationIllustrated Parts List
Illustrated Parts List. Ordering Parts For your convenience, replacement parts and accessories can be ordered from ARPAC by fax 24 hours a day. Please have the following information available to ensure
More informationReproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.
SERVICE MANUAL ELECTRIC BRAISING PANS (30 & 40 GALLON) VE30 VE40 ML-126849 ML-126850 VE40 SHOWN - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used
More informationTHUNDERBIRD. Agricultural Weighing Systems SS1000 Instructions
THUNDERBIRD Agricultural Weighing Systems SS1000 Instructions Installation Locate a weighing site that is well drained. For best weighing results, ensure the weigh bars and weighing platform are on a level
More informationModel Combustible Gas Sample Draw Detector Head Operator s Manual
Model 1017-06 Combustible Gas Sample Draw Detector Head Operator s Manual Part Number: 71-0356 Revision: P1 Released: 2/4/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before
More informationPRODUCT INFORMATION BULLETIN
724-283-4681 724-283-5939 (fax) PRODUCT INFORMATION BULLETIN DESCRIPTION The, Model 10-7100 is one in a series of critical speed switches that monitor speed and detect motion in all types of machinery
More informationInstallation and Service Manual
RESIDENTIAL PLATFORM LIFTS RPL400 / RPL600 Installation and Service Manual WARNING! STRICT ADHERENCE TO THESE INSTALLATION INSTRUCTIONS IS REQUIRED to promote the safety of those installing this product,
More informationCetra Assembly Instructions
99877 Revision F- Complete Series Master Packet If you have any questions concerning these instructions, please call Kimball Office Customer Service. 0 Kimball International, Inc. T 800.8.88 F 8.8.800
More informationModel Combustible Gas Sample Draw Detector Head Operator s Manual
Model 1017-07 Combustible Gas Sample Draw Detector Head Operator s Manual Part Number: 71-0480 Revision: P1 Released: 1/4/19 www.rkiinstruments.com WARNING Read and understand this instruction manual before
More informationAQT-275 SERIES SERVICE MANUAL CONTROL VALVES
AQT-275 SERIES CONTROL VALVES SERVICE MANUAL Table of Contents General Residential Installation 3 Valve Start-up Procedures 4 Regeneration Cycle Program Setting Procedures 5 Water Conditional Diagrams
More informationARCHWEIGH 1000 BELT SCALE WITH TOUCH PANEL DISPLAY
ENVIRONMENTAL EQUIPMENT, INC. ARCH ARCHWEIGH 1000 BELT SCALE WITH TOUCH PANEL DISPLAY INSTALLATION / WIRING / OPERATION (EZ/EATON ) 5/07 Post Office Box 1760 5929 Benton Road Paducah, KY 42002-1760 PHONE:
More informationSmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE
BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 925-0312 Rev B TABLE OF
More informationRated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
WPC-1 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH POOL AND
More informationACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE:
ACCUVALVE MODEL AVC6000 SUBMITTAL MODEL CODE WARNING: NOT FOR USE WITH PERCHLORIC ACID MATERIALS VALVE HOUSING MATERIAL 2 = 304SS, 20 GAUGE 3 = 316SS, 20 GAUGE 4 = ALUMINUM, 16 GAUGE 6 = HIGH TEMP 304SS,
More informationInstructions EM 101 Low Flow Electromagnetic Flow Meters
PDF Published June 3, 2004 Instructions EM 101 Low Flow Electromagnetic Flow Meters Installation Mounting The EM 101 model has a flow meter unit and a separate control unit containing a LCD display. The
More informationOpening Quality Doors Around The World. Installation Instructions Bi-Parting Freight Doors - Q Style (Power and Manual)
Opening Quality Doors Around The World www.couriondoors.com Installation Instructions Bi-Parting Freight Doors - Q Style (Power and Manual) Table of Contents For Immediate Help Call 1-800-533-5760 Q Style
More informationM9206-Bxx-2S Series On/Off Electric Spring Return Actuators
Installation Instructions M9206-Bxx-2S Issue Date May 14, 2003 M9206-Bxx-2S Series On/Off Electric Spring Return Actuators Installation IMPORTANT: Use this M9206-Bxx-2S Series actuator to control equipment
More informationJOHN DEERE Scale System
JOHN DEERE 4930-4940 Scale System Installation Instructions And Repair Parts 60090 REVE TABLE OF CONTENTS Anamosa, Iowa USA TABLE OF CONTENTS INTRODUCTION... 4 Charging Battery and Welding... 4 SCALE BRACKET
More informationRoughDeck TM FXB Flexure Base Floor Scale. Installation/Operation Manual
RoughDeck TM FXB Flexure Base Floor Scale Installation/Operation Manual SM 32958 13 Contents 1. Introduction... 1 1.1 Scale Components... 1 1.2 Operating Requirements... 2 1.3 How Flexure Levers Work...
More informationSummit 3000 Low-Profile Floor Scale. Installation Manual
Summit 3000 Low-Profile Floor Scale Installation Manual 76012 Contents 1.0 Introduction and System Overview... 1 1.1 Operating Requirements........................................................... 1
More informationMA-5200 Series MA-5300 Series
MA-5200 Series MA-5300 Series Two-Position Actuators General Instructions Application The MA-5200 series and MA-5300 series actuators are used for two-position control of valves and dampers which require
More informationSpeed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE
Speed Sensor ã Read and understand equipment operators manual before operating or performing maintenance. Failure to do so could result in serious injury or death. Safety Information Failure to follow
More informationRated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
WPC1-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH
More informationSTRESS-TEK, INC S. 194 th Street Kent, WA June 2011 Stress-Tek, Inc. Doc Rev A
Installation, Setup and Calibration of Vulcan Deflection Sensors on Hendrickson 462/463 and Haulmaxx Equalizing Suspension Beams (Includes Models HN 402, HN 462, HN FR, RT 463, RTE 463, HMX and HMX 400.)
More informationInstallation Instructions
Quick-Mount Visual Instructions for Quick-Mount Visual Instructions 1. Rotate the damper to its failsafe position. If the shaft rotates counterclockwise, mount the CCW side of the actuator out. If it rotates
More informationType 2000 Transducer Product Instructions
Type 2000 Transducer Product Instructions The Type 2000 is an electro-pneumatic device that regulates an unregulated supply pressure down to an electronically-controlled output pressure. There are two
More informationHomestyle Frontload Washers
Homestyle Frontload Washers Parts Refer to Page 3 for Model Numbers FLW2406N_805862 www.alliancelaundry.com Part No. 805862R1 June 2015 Table of Contents Title Page Parts Ordering Information... 2 Serial
More informationRoughDeck BDP. Barrel Scale. Installation/Operation Manual
RoughDeck BDP Barrel Scale Installation/Operation Manual 78065 Contents 1.0 Introduction and System Overview... 1 1.1 Model Designations.............................................................. 2
More informationACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS
II 1400-8 Features: ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS Filtered/Regulated 24 Volts DC Up to Full 2 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit
More informationINSTALLATION, OPERATING AND SERVICE MANUAL
INSTALLATION, OPERATING AND SERVICE MANUAL ECONO-mist WATER SOFTENER Demand Regeneration 7-LMC56-75B 7-LM56-75B 7-LM56-100B 7-LM56-150B 7-LM56-200B Congratulations on purchasing your new Lancaster Water
More informationJandy Pro Series WaterColors LED Lights Underwater Large and Small Light
installation Manual English Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified
More informationMAPNET II Transceiver Installation Instructions
MAPNET II Transceiver Installation Instructions Introduction This publication describes the installation procedure for the following versions of the MAPNET II Transceiver card. 4120/4100-0110 MAPNET II
More informationInteli-Lift GEN II DUMBWAITER
1 877-345-4387 530-295-4900 www.eilifts.com Inteli-Lift GEN II DUMBWAITER The Easiest Dumbwaiter system on the Market Fully UL Certified Dumbwaiter Systems UL File # SA32120 This manual will cover the
More informationEM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE
EM101 LOW FLOW MAGNETIC FLOW METER INSTRUCTIONS EM 101 LOW-FLOW MAGNETIC FLOW METER INSTRUCTIONS EM 101-025 EM 101-038 EM 101-050 GENERAL INFORMATION The EM101 is a small plastic-bodied electromagnetic
More informationInlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00
Inlet Controller TC5-ITA USER'S MANUAL M 890-00047 rev. 02 K 895-00458 rev. 00 TABLE OF CONTENTS PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE CONTROLS... 5 Status Leds...5 Internal Switches...6 INSTALLATION
More informationHow to Select the RE Industrial Actuator Part Number
How to Select the RE Industrial Actuator Part Number RE 10 T F 2 Torque (in-lb) 1.5 150 3 300 6 600 8.5 850 10 1000 15 1500 20 2000 25 2500 30 3000 Reversing Electronic Torque Maximizer (optional) Increases
More informationGE Sensing & Inspection Technologies
GE Sensing & Inspection Technologies Modus Model RPM-1 Room Pressure Monitor Installation and Setup Guide 1. GENERAL The RPM-1 monitors either positive or negative room pressures (see the Datasheet for
More informationPN: 6410T0022 Rev. 8/18/2014 Revision D Albany RR300 Stainless Mechanical Install & Owner s Manual
PN: 6410T0022 Rev. 8/18/2014 Revision D Albany RR300 Stainless Mechanical Install & Owner s Manual ASSA ABLOY ENTRANCE SYSTEM. All Rights Reserved 975-A Old Norcross Road, Lawrenceville, Georgia 30046
More informationD-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators
Installation D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators IMPORTANT: The D- Series actuators are intended to control equipment under normal operating conditions. Where failure
More informationIllustrated Parts List
Illustrated Parts List. Ordering Parts For your convenience, replacement parts and accessories can be ordered from ARPAC by fax 24 hours a day. Please have the following information available to ensure
More informationMK IV OVERHEAD DOOR REPLACEMENT PARTS BOOK
MK IV OVERHEAD DOOR REPLACEMENT PARTS BOOK JAMISON DOOR COMPANY P.O. BOX 70 HAGERSTOWN, MARYLAND 21740 1-800-532-3667 301-733-3100 INTERNET: http://www.jamisondoor.com E-MAIL: contact@jamisondoor.com ECN
More informationSignet Temperature Transmitter
Signet 80 Temperature English 80.090 80.090 Rev. G /0 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents.
More informationMF /MS Series
MF41-6153/MS41-6153 Series 24 Vac, Three-position/Modulating Non-spring Return Rotary Electronic Damper SmartX Actuators General Instructions Description The direct-coupled, 24 Vac, non-spring return electronic
More informationFincor Series 2230 MKII/2240
Fincor Series 2230 MKII/ Fincor Series 2200 regenerative drives are ideal for your more demanding applications. They feature flexibility with ratings up to 5 horsepower. The Series 2230 MKII offers new
More informationVertical Vinyl Curtain Door
Vertical Vinyl Curtain Door Face Mount Installation Instructions System Overview: Your Aleco Vinyl Vertical Curtain Door is a high quality, high performance flexible door system based on proven components
More informationC3600P AND C7200P OPERATION INSTALLATION AND SERVICE MANUAL PRECISION TON CONTAINER SCALES
C3600P AND C7200P OPERATION INSTALLATION AND SERVICE MANUAL PRECISION TON CONTAINER SCALES EAGLE MICROSYSTEMS, INC. 366 Circle of Progress, Pottstown, PA 19464 610-323-2250 Phone - 610-323-0114 Fax e-mail:
More informationOne Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series
Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Low-Profile, single-circuit trac sections for surface or pendant mounting. I-beam cross section provides added strength and
More informationPFadvantage JD 3300/4400/6600/7700; 4420
Ag Leader Technology Combine Installation JD 33//66/77; 2 Note: Indented items indicate parts included Quantity by Model in an assembly listed above Early Late Part Name/Description Part Number 3 3 6 6
More informationModel Combustible Gas Sample Draw Detector Head Operator s Manual
Model 1017-01 Combustible Gas Sample Draw Detector Head Operator s Manual Part Number: 71-0058RK Revision: B Released: 5/24/13 www.rkiinstruments.com WARNING Read and understand this instruction manual
More informationInsertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT
TECHNICAL PRODUCT INSTRUCTION SHEET Insertion turbine OVERVIEW These insertion flow transducers provide a cost effective and simple means of measuring the flow of a wide range of low viscosity liquids.
More informationIDS INDUSTRIAL DISPENSER INSTRUCTIONS ISO SAFETY INSTRUCTIONS
ISO9 SAFETY Before using any Fluid Metering, Inc. product read the following safety instructions as well as specific product specifications and operating instructions. Warning! Fire, electrical shock or
More informationDENISON HYDRAULICS Jupiter 500 Driver Card Series S
Back to Content DENISON HYDRAULICS Jupiter 500 Driver Card Series S20-11712-0 Publ. 9-AM681 E-Mail: denison@denisonhydraulics.com Internet: http://www.denisonhydraulics.com SYSTEM FEATURES SYSTEM FEATURES
More informationALL W INSTALLATION INSTRUCTIONS
ALL1000-3300W INSTALLATION INSTRUCTIONS Aladdin Light Lift, Inc. (256) 429-9700 61 Shields Road (877) 287-4601 Huntsville, AL 35811 www.aladdinlightlift.com Patent #5105349 WARNING: Disconnect power source
More informationUser Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736
User Manual T6 Tachometer Online: www.phareselectronics.com Telephone: 727-623-0894 P.O. Box 67251 St. Petersburg, Florida 33736 Table of Contents Overview... 1 Description... 1 Wiring... 1 T6 Tachometer
More informationAQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)
AQUASTAR C6 (Comfort 6000) Next Generation Auto Backwash Valve System (selectable time-pressure or remote cycle start) SIDE MOUNTED AND TOP MOUNTED VALVES WITH QUICK INSTALL ELECTRIC ACTUATORS FOR PIPE
More informationWaterproof 4X Telephone Model WP80
Industrial Communications Worldwide Waterproof 4X Telephone 1 2 3 4 5 6 7 8 * 0 9 # P004963 Rev. D 11/23/2004 11:43 7552-10th Street N.E. Calgary, Alberta, Canada T2E 8W1 Ph: 403.258.3100 \ email:info@guardiantelecom.com
More informationMaster Series Gas XPress Grill
Master Series Gas XPress Grill models XG24, XG36 (non-ce & CE versions) Phone (US & Canada): 800 427 6668 Fax (US & Canada): 800 36 7745 www.garland-group.com G_GHD_PL_XPRESS_XG24ANDXG36 (Rev ) Quality
More informationInstallation and Operation Instructions DLP Series
Installation and Operation Instructions DLP Series PRECAUTIONS Figure 1: DLP Dimensions and Hardware REMOVE POWER BEFORE WIRING. NEVER CONNECT OR DISCONNECT WIRING WITH THE POWER APPLIED. DO NOT ALLOW
More informationDistributed by: M&M Control Service, Inc MICRO-FLO MICRO-FLO
Digital Paddlewheel Flow meter Operating Manual Blue-White Industries, Ltd. Page 2 TABLE OF CONTENTS 1...Introduction...2 2...Features...3 3...Model number matrix...3 4...Specifications...4 4.1..Temperature
More informationPorta-Tronic. Portable Scales. INSTALLATION GUIDE Version 2.0
Porta-Tronic Portable Scales INSTALLATION GUIDE Version 2.0 GSE Porta-Tronic Installation Guide Copyright 2008 GSE. All rights reserved. Published by: GSE 1525 Fairlane Circle Allen Park, MI 48101 www.gse-inc.com
More informationEM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS
Spec Tech Industrial 203 Vest Ave. Valley Park, MO 63088 Phone: 888 SPECTECH Email: sales@spectechind.com www.spectechind.com EM101 EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS LOW FLOW MAGNETIC FLOWMETER
More informationInstallation Instructions Z-Gate Shifter
Installation Instructions Z-Gate Shifter Part Number 80681 1998, 2001 by B&M Racing and Performance Products The B&M Z-Gate shifter can be used in vehicles equipped with most popular three speed automatic
More informationBelt Scales Table of Contents
Belt Scales Table of Contents Master 311M...164 Medium to Heavy Capacity Weigh Frame Master 221DB...165 Medium to Heavy Capacity Belt Scale Master 211...166 Medium to Heavy Capacity Weigh Frame Master
More informationENCORE S20/L20. Parts and Service Manual. Section II (74836B) CLARKE TECHNOLOGY Operator's Manual - Encore S20/L20 Page -17-
ENCORE S0/L0 Section II Parts and Service Manual (8B) CLARKE TECHNOLOGY Operator's Manual - Encore S0/L0 Page -1- HOW TO CORRECT PROBLEMS IN THE MACHINE PROBLEM CAUSE ACTION There is no solution flow.
More informationVision 17B/BT. Section II Parts and Service Manual (78454B) CLARKE TECHNOLOGY Operator's Manual - Vision 17B/BT Page -23-
Vision 17B/BT Section II Parts and Service Manual (78454B) Operator's Manual - Vision 17B/BT Page -23- HOW TOO CORRECT PROBLEMS IN THE MACHINE PROBLEM CAUSE ACTION There isn't any solution flow. The solution
More informationtable of Contents Warranty:
table of Contents placement of the Mounting Bolts spudnik swingout... 2 spudnik solid... 2 logan swingout... 3 logan solid... 3 double l swingout... 4 double l solid... 4 Mounting Framework... 5-6 Mounting
More informationRESISTIVITY MONITOR/CONTROLLERS
RESISTIVITY MONITOR/CONTROLLERS Installation Operation Maintenance User Manual for Models: 750, 752, 753, 762 2450 Impala Drive Carlsbad, CA 92010-7226 USA Tel: 1-760-438-2021 Fax: 1-800-869-7668 / 1-760-931-9189
More informationConvertamatic 285LX Hydro-Retriever 285HD Lynx 285
Convertamatic 285LX Hydro-Retriever 285HD Lynx 285 PARTS LIST Advance MODELS 56391007(285LX) 56391008(285HD & Lynx) All models covered in this manual are Obsolete. This parts list is for machines after
More informationSLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS
SLC-811X Series TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com Single Loop Proportional Temperature Controller General Instructions APPLICATION Electronic temperature controller
More informationGENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:
π H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count counting scale 1-800-295-5510 uline.com 1-800-295-5510 GENERAL INFORMATION Avoid placing the scale in locations that may hurt accuracy: 1. Temperature
More informationInstallation, Operation & Maintenance Manual. Bulletin: IOMS-PUL CHEMAlarm LEAK DETECTIONI
Installation, Operation & Maintenance Manual Bulletin: IOMS-PUL-1011 CHEMAlarm LEAK DETECTIONI 1 TABLE OF CONTENTS 1. PRINCIPLES OF OPERATION... 3 1.1 General Description... 3 1.2 Process Specifications...
More informationINSTALLATION & MAINTENANCE MANUAL
A Subsidiary of Dynamic Instruments INSTALLATION & MAINTENANCE MANUAL A Subsidiary of Dynamic Instruments 3860 Calle Fortunada San Diego, CA 92123-1825 Phone: 1-(800) 821-5831 Web Site: hardyinst.com (858)
More informationSafe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual
Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual For Use with: SNS4, SNS6, SNS10 & SNS15 Models Additional supplements may be needed for
More informationHomestyle Frontload Washers
Homestyle Frontload Washers Parts Refer to Page 3 for Model Numbers FLW2406N_805862 www.alliancelaundry.com Part No. 805862R7 March 2017 Table of Contents Title Page Parts Ordering Information... 2 Serial
More informationGPS AutoSteer System Installation Manual
GPS AutoSteer System Installation Manual Supported Vehicles Case IH Vehicles Case 2577 Combines Case 2588 Combines Accuguide Ready PN: 602-0233-01-A LEGAL DISCLAIMER Note: Read and follow ALL instructions
More informationInstallation Instructions
Installation Instructions MX3635-01 Rev. E Models HydraSwing 40s HydraSwing 40F 4,000 lb (1,814 kg) 10-15 seconds HydraSwing 40 4,000 lb (1,814 kg) 15-20 seconds HydraSwing 40 Twin 4,000 lb (1,814 kg)/leaf
More informationTITAN Motor Truck Scale
S C A L E S Instruction Manual TITAN Motor Truck Scale Model: 00 Series FAIRBANKS 00 by Fairbanks Scales Inc. All rights reserved 0 Revision # 0/0 Amendment Record Titan 00 Series Motor Truck Scale 0 Manufactured
More informationMETROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide
METROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide Copyright 2007 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced,
More information