Fryer Replacement Field Monitoring Study Report

Size: px
Start display at page:

Download "Fryer Replacement Field Monitoring Study Report"

Transcription

1 Fryer Replacement Field Monitoring Study Report Fisher Nickel Inc. November, 214 Prepared By: Denis Livchak Contributors: Richard Young Prepared For: Anthony Hills Southwest Gas North Las Vegas, NV 893 and Todd Megrath MGM Resorts International Las Vegas, NV 8919 Test Site: Aria Resort & Casino 373 S Las Vegas Blvd Las Vegas, NV 8919 Test Date: June - 214

2 Study Test Date: June - September, 214 Facility name: Aria Resort & Casino Facility Address: 373 S Las Vegas Blvd Las Vegas, NV 8919 Introduction: The Aria Resort and Casino is a part of the CityCenter complex on the Las Vegas Strip. This 61 story resort has 16 restaurants and 1 bars and nightclubs. Aria Café is the largest 24 hour café on the Las Vegas Strip serving casual dishes in a sophisticated and contemporary setting (Figure 1). Aria Buffet is open for breakfast, lunch and dinner and serves a plethora of fresh dishes spanning several continents. Figure 1. Aria Café Dining Room In its quest to increase cooking production capacity and meet corporate sustainability goals, MGM Resorts is exploring several options to replace their outdated fryers. MGM contacted Southwest Gas which arranged funding for the project through its participation in the Utilization Technology Development, NFP (UTD) with the Gas Technology Institute (GTI). The UTD, a not-for-profit corporation, is directed by participating companies, to manage a gas-focused technology program for the benefit of the investors and their customers. GTI, Southwest Gas collaborated with the Food Service Technology Center for technical support and assistance in analyzing energy usage of existing fryers and quantifying energy savings associated with energy efficient alternatives. The Food Service Technology Center assisted Southwest Gas in selecting metering equipment which was used for monitoring the energy consumption of the three existing double vat fryers at two restaurant locations. After baseline energy monitoring was conducted on the existing fryers, they were replaced by energy efficient fryers of the same size and monitored for several weeks. Hours of operation, usage patterns and daily energy consumption was analyzed. Baseline and replacement data was compared in order to justify future replacement of inefficient fryers at other MGM sites.

3 Test site: The sites chosen for baseline energy monitoring had the most customers or had the longest hours of operations. Aria Café is a 24/7 restaurant with two double vat fryers that are operated at alternate shifts. Aria Buffet is open from 7AM to 1PM daily and has a steady stream of customers anytime between those hours. Both kitchens require a high volume production fryer to be able to keep up with the customer demand. Aria Café has a large kitchen with several lines high duty cooking appliances. The two double vat fryers were located on the opposite sides of the kitchen hood (Figure 2). The fryers were missing front casters and were leaning forward causing the oil level to be uneven. At the Aria Buffet, the double vat fryer was located in the back of the kitchen (Figure 3). All three gas double vat fryers were the same model and had a maximum input rate of 12 kbtu/h per vat. Each vat was 15" wide and had an oil capacity of 5 lb heated by two atmospheric burners. Each vat had a standing pilot that was operating 24/7 and manual millivolt thermostats. Figure 2. Aria Café Baseline Fryer Figure 3. Aria Buffet Baseline Fryer

4 Monitoring Equipment and Testing Procedures: Southwest Gas Engineers assembled the data logger enclosure and attached it to the gas meter. The gas meter was then attached to the back panel which contained all the utility connections (Figure 4). The gas meter was then connected inline between the fryer and the gas source. Each double vat fryer had one gas connection and both vats were utilized simultaneously. The gas meter generated a pulse for every cubic foot that was consumed (Figure 5) and pulses were recorded using an Onset HOBO data logger at 3 second intervals. Data was downloaded manually during different periods of monitoring. Figure 4. Gas Meter with Data Logger During baseline monitoring there were some problems with the gas meters due to the cleaning practices of the staff. The plastic gas meter gears fell out of position when the meter was hit during intensive cleaning. Southwest Gas replaced two of the gas meters and reprogrammed the data loggers. The baseline monitoring period at the Aria Café was extended due to these technical difficulties. Initially, it was assumed that the two fryers at Aria Café were used intermittently, however the baseline data suggests otherwise and there were several days when both fryers are operating simultaneously. The first fryer was used 77% of the time and the second fryer is used 73% of the time, not 5/5 as suggested earlier. The overlay when both fryers are operating simultaneously occurred during the weekend days of Friday and Saturday. Initially the energy during off days was attributed to the standing pilot light, however it was discovered that instead of being turned off, the fryer thermostat was set on the minimum setting at Aria Café. Figure 5. Gas Meter Readout

5 Data and Results Baseline: At Aria Café, the first baseline fryer consumed therms per day when it was in use, and 3.8 therms when it was not. During the monitoring period, the fryer was in use 77% of the time. This means the weighted average throughout the week was 1.19 therms per day. A typical on profile is shown in Figure 6 and a typical profile during non-operation days is shown in Figure 7 which shows the low temperature idle between 5AM and 9AM and the pilot energy rate between 1AM and 1PM Figure 6. Aria Café Baseline Fryer 1 Typical On Day Figure 7. Aria Café Baseline Fryer 1 Typical Non-Operating Day

6 At Aria Café, the second baseline fryer consumed 1.62 therms per day when it was in use and 1.9 therms when it was not. During the monitoring period, the fryer operated 73% of the time. This means the weighted average throughout the week was 8.24 therms per day. A typical on profile is shown in Figure 8 and a typical non-operational profile is shown in Figure 9 which shows the low temperature idle Figure 8. Aria Café Baseline Fryer 2 Typical On Day Figure 9. Aria Café Baseline Fryer 2 Typical Non-Operating Day

7 At Aria Buffet, the baseline fryer operated every day and consumed 7.96 therms per day on average. A typical energy usage profile is shown in Figure 1. The pilot rate is shown between 1PM and 4AM Figure 1. Aria Buffet Baseline Fryer Typical Daily Profile Replacement: After baseline monitoring has been completed, three high input rate low efficiency fryers were replaced by top of the line fryers from three major manufacturers. These were the most efficient fryers of equivalent size available on the market by the three selected manufacturers. The replacement fryers featured more efficient gas heat exchanger technologies and power burners compared to the baseline fryers; however the analog controls remained very similar. At Aria Café, the first baseline fryer was replaced with two Frymaster H55 series fryers (Figure 11). The replacement consumed 5.48 therms per day when it was in use and 1.99 therms when it was not. During the monitoring period, the fryer operated 77% of the time. This means the weighted average throughout the day was 5.51 therms per day. A typical on profile is shown in Figure 12 and a typical off profile is shown in Figure 13 low temperature idle. Figure 11. Aria Café Replacement Fryer 1

8 Figure 12. Aria Café Replacement Fryer 1 Typical On Day Figure 13. Aria Café Replacement Fryer 1 Typical Non-Operating Day The replacement of the existing baseline double vat fryer at Aria Café with two Frymaster H55 fryers resulted in 54% energy reduction amounting to 5.51 therms per day.

9 At Aria Café, the second baseline fryer was replaced with two Vulcan 1VK45 series fryers (Figure 14). The replacement consumed 4.2 therms per day when it was in use and.93 therms when it was not. During the monitoring period, the fryer operated 73% of the time. This means the weighted average throughout the day was 3.31 therms per day. A typical on profile is shown in Figure 15 and a typical off profile is shown in Figure 16 which shows that the fryer was completely off after 2AM. Figure 14. Aria Cafe Replacement Fryer Figure 15. Aria Café Replacement Fryer 2 Typical On Day Figure 16. Aria Café Replacement Fryer 2 Typical Off Day

10 The energy during off days was significantly lower for the replacement fryer because it had electronic ignition and did not require a standing pilot. The staff kept these fryers completely off compared to leaving them on at a low temperature idles shown with the other fryer at the Aria Café. The energy usage between hours and 2 is carryover energy from the previous on day. The replacement of the existing baseline double vat fryer with two Vulcan 1VK45 fryers resulted in 6% energy reduction amounting to 4.93 therms per day. At Aria Buffet, the baseline fryer was replaced with two Pitco SSH55 series fryers (Figure 17). The replacement fryers operated every day and consumed 3.41 therms per day on average. This fryer had electronic ignition which meant that it did not use any pilot energy. A typical energy usage profile is shown in Figure 18. Figure 17. Aria Buffet Replacement Fryer Figure 18. Aria Buffet Replacement Fryer Typical Daily Profile The replacement of the existing baseline double vat fryer with two Pitco SSH55 fryers resulted in 57% energy reduction amounting to 4.55 therms per day.

11 Conclusion: Baseline fryer replacement with energy efficient fryers resulted in significant energy savings across all three sites. The average savings were 57% or 5 therms per day per site. The table below summarizes the replacement results for all the sites. Table 1. Gas Therm Savings at Each Monitored Location Location Café 1 Café 2 Buffet Pre Post Savings Savings 54% 6% 57% Baseline Replacement 12 Energy Usage (therms/day) Café 1 Café 2 Buffet Figure 19. Aria Replacement Fryer Energy Savings The significant fryer energy savings were attributed to much more efficient heat exchangers, power burners and electronic ignition in replacement fryers. Figure 2 shows an overlay of the baseline and replacement energy profiles for the same location. Pilot energy is eliminated and the replacement fryer is idling at a much lower input rate while maintaining the same temperature and improving production capacity through faster recovery times.

12 Baseline Replacment Figure 2. Baseline vs Replacement Fryer Energy Profiles. It was initially though that the baseline fryer at Aria Café had a very high pilot rate accounting for almost 3 therms during off days. This suggests that the pilot rate was above 1 kbtu/h (Figure 21). Once the replacement fryer with electronic ignition was installed, the same pattern emerged, although this perceived pilot rate was lower at 2 therms per day. This meant that instead of turning the fryer off during off days, the operator would simply turn down the thermostat on the minimum setting instead of turning off the fryer completely. This observation is highlighted by the preheat spike preceding the low temperature idle. Figure 22 illustrates this on the replacement fryer, where it was truly off between and 6 am, then preheated at 7 am. Between 7 am and 11 pm the fryer was idling at a low rate indicating that the thermostat was set very low, however no cooking was taken place because it is a steady idle. At 11pm the fryer was preheated to cooking temperature.

13 12 1 Low Temp Preheat Fryer Off Fryer Thermostat Turned Down, No Cooking Figure 21. Fryer Thermostat Reduction Instead of Turning it Off Baseline Fryer Fryer Off Low Temp Preheat High Temp Preheat Fryer Thermostat Turned Down, No Cooking Figure 22. Fryer Thermostat Reduction Instead of Turning it Off Replacement Fryer Instructing the staff to turn off the fryer instead of turning down the thermostat during the off days can save 2 therms per day even with the replacement fryers.

14 Appendix: Baseline Fryer for all Three Sites:

15 Appendix: Baseline Fryer for all Three Sites:

16 Appendix: Aria Café Replacement Fryer 1 Spec Sheet:

17 Appendix: Aria Café Replacement Fryer 1 Spec Sheet:

18 Appendix: Aria Café Replacement Fryer 2 Spec Sheet:

19 Appendix: Aria Café Replacement Fryer 2 Spec Sheet:

20 Appendix: Aria Buffet Replacement Fryer Spec Sheet:

21 Appendix: Aria Buffet Replacement Fryer Spec Sheet:

Service Bulletin. (This bulletin and all other active bulletins are downloadable from our website at

Service Bulletin. (This bulletin and all other active bulletins are downloadable from our website at Bulletin 00--ABDE Service Bulletin (This bulletin and all other active bulletins are downloadable from our website at www.frymaster.com/parts_service.) Bulletin 00--ABDE Page of + Worksheets Date: 0//00

More information

Watlow Model Firebar 1000 and 1600 Prototype Element Performance Test

Watlow Model Firebar 1000 and 1600 Prototype Element Performance Test Watlow Model Firebar 1000 and 1600 Prototype Element Performance Test In a standard fryer In accordance with ASTM Standard Test Method F 1361-95 FSTC Report 5011.98.60 Food Service Technology Center Manager:

More information

Meter Insights for Downtown Store

Meter Insights for Downtown Store Meter Insights for Downtown Store Commodity: Analysis Period: Prepared for: Report Date: Electricity 1 December 2013-31 December 2014 Arlington Mills 12 February 2015 Electricity use over the analysis

More information

Annex 1. Field Report: Solar Electric Light Fund Energy Harvest Control Study

Annex 1. Field Report: Solar Electric Light Fund Energy Harvest Control Study Annex 1. Field Report: Solar Electric Light Fund Energy Harvest Control Study 3 Procedures: 3.1 Incoming Inspection and Labeling: The components were unpacked and labeled according to CFV Solar convention.

More information

Food Service Technology Center

Food Service Technology Center Food Service Technology Center Frymaster BIELA214-2RCSD Electric Fryer Test Report Application of ASTM Standard Test Method F1361-07 September 2016 Prepared by: Edward Ruan Fisher-Nickel, Inc. Contributors:

More information

LOV-T FRYER COMMISSION AND DEMONSTRATION FORM 8700 LINE AVENUE SHREVEPORT, LA (800) Date

LOV-T FRYER COMMISSION AND DEMONSTRATION FORM 8700 LINE AVENUE SHREVEPORT, LA (800) Date LOV-T FRYER COMMISSION AND DEMONSTRATION FORM 8700 LINE AVENUE SHREVEPORT, LA 71106 (800) 551-8633 Date Store Technician Store # (if applicable) Service Agency Address Address City/State City/State Store

More information

Food Service Technology Center

Food Service Technology Center Food Service Technology Center Giles GGF-400 Gas Fry Kettle FSTC Report # 501311131-R0 Application of ASTM Standard Test Methods F1964-11, 1361-07 December 2012 Prepared by: Adam Cornelius Denis Livchak

More information

Effect of DG Installation on Customer Load Shapes

Effect of DG Installation on Customer Load Shapes Effect of DG Installation on Customer Load Shapes P R E S E N T E D T O Westar Energy P R E S E N T E D B Y The Brattle Group J u n e 2 3, 2017 Copyright 2017 The Brattle Group, Inc. Characteristics of

More information

TECHNOLOGY AND MARKET TRIALS PROGRAM. Final Report Motorboss Motor Controller Field Test

TECHNOLOGY AND MARKET TRIALS PROGRAM. Final Report Motorboss Motor Controller Field Test Las Vegas, Nevada TECHNOLOGY AND MARKET TRIALS PROGRAM Final Report Motorboss Motor Controller Field Test Levi Strauss and McCarran Airport Test Sites Prepared By: Prepared For: Larry Holmes Program Manager,

More information

Food Service Technology Center

Food Service Technology Center Food Service Technology Center Sapidus H2Oil UE-1100 (240V) Electric Fryer Test Report Application of ASTM Standard Test Method F1367-07 November 2015 Prepared by: Edward Ruan Fisher-Nickel, Inc. Contributors:

More information

Utility and project update 2-3 Project description 4

Utility and project update 2-3 Project description 4 The concept of collaboration doesn t make for interesting headlines. But this kind of good news is definitely worth noting, even as other highlights of the project may seem much more exciting. Utility

More information

Vulcan-Hart Gas Steamer Performance Testing Model VHX24G-3

Vulcan-Hart Gas Steamer Performance Testing Model VHX24G-3 Vulcan-Hart Gas Steamer Performance Testing Model VHX24G-3 Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.01.97 Food Service Technology Center Final Report, February 2001 Prepared

More information

An Investigation of the Distribution of Driving Speeds Using In-vehicle GPS Data. Jianhe Du Lisa Aultman-Hall University of Connecticut

An Investigation of the Distribution of Driving Speeds Using In-vehicle GPS Data. Jianhe Du Lisa Aultman-Hall University of Connecticut An Investigation of the Distribution of Driving Speeds Using In-vehicle GPS Data Jianhe Du Lisa Aultman-Hall University of Connecticut Problem Statement Traditional speed collection methods can not record

More information

AGA Oil to Electric Conversion kit with AIMS (AGA INTELLIGENT MANAGEMENT SYSTEM)

AGA Oil to Electric Conversion kit with AIMS (AGA INTELLIGENT MANAGEMENT SYSTEM) AGA Oil to Electric Conversion kit with AIMS (AGA INTELLIGENT MANAGEMENT SYSTEM) FREQUENTLY ASKED QUESTIONS AIMS was discontinued as a factory option for 13amp electric and gas AGAs in 2015 however the

More information

Eagle Park Health Care Facility

Eagle Park Health Care Facility Eagle Park Health Care Facility Ergonomic Trolley OHSAH Date: July 29/02 Occupational Health and Safety Agency for Healthcare #301 1195 West Broadway Vancouver, B.C. V6H 3X5 604.775.4034 www.ohsah.bc.ca

More information

SMART METER TEXAS. Transcript of Smart Meter Texas Demonstration in English. Smart Meter Texas Version 1.0, January 30, 2010

SMART METER TEXAS. Transcript of Smart Meter Texas Demonstration in English. Smart Meter Texas Version 1.0, January 30, 2010 SMART METER TEXAS Transcript of Smart Meter Texas Demonstration in English SMT Flash Demo Transcript English Page 1 1 Electricity We all think about it to some extent but how much electric energy are you

More information

Vulcan, VPX5 Electric Steamer Performance Test

Vulcan, VPX5 Electric Steamer Performance Test Vulcan, VPX5 Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.01.02 Food Service Technology Center Final Report, May 2001 Prepared by: Todd Bell Fisher-Nickel

More information

Downtown Lee s Summit Parking Study

Downtown Lee s Summit Parking Study Downtown Lee s Summit Parking Study As part of the Downtown Lee s Summit Master Plan, a downtown parking and traffic study was completed by TranSystems Corporation in November 2003. The parking analysis

More information

Vulcan, VPX3 Electric Steamer Performance Test

Vulcan, VPX3 Electric Steamer Performance Test Vulcan, VPX3 Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.01.01 Food Service Technology Center Final Report, May 2001 Prepared by: Todd Bell Fisher-Nickel

More information

Exploring Electric Vehicle Battery Charging Efficiency

Exploring Electric Vehicle Battery Charging Efficiency September 2018 Exploring Electric Vehicle Battery Charging Efficiency The National Center for Sustainable Transportation Undergraduate Fellowship Report Nathaniel Kong, Plug-in Hybrid & Electric Vehicle

More information

CHAPTER III SYSTEM DESIGN

CHAPTER III SYSTEM DESIGN Chapter 3 System Design CHAPTER III SYSTEM DESIGN GENERAL This section will cover the proper design of the Protex Series II Restaurant Fire Suppression System. It is divided into four (4) sections: Cylinder

More information

PARKING OCCUPANCY IN WINDSOR CENTER

PARKING OCCUPANCY IN WINDSOR CENTER PARKING OCCUPANCY IN WINDSOR CENTER TOWN OF WINDSOR, CONNECTICUT REPORT JUNE 2017 CONTENTS Background... 3 Other Relevant Data... 3 Parking Survey Design... 6 Parking Supply Inventory... 6 Parking Demand

More information

Thermal Engineering Corporation (TEC ) Searmaster II, Model SM2103 Underfired Broiler Performance Test

Thermal Engineering Corporation (TEC ) Searmaster II, Model SM2103 Underfired Broiler Performance Test Thermal Engineering Corporation (TEC ) Searmaster II, Model SM2103 Underfired Broiler Performance Test Application of ASTM Standard Test Method F 1695-03 FSTC Report 501310104 March 2011 Prepared by: Greg

More information

2013 Spring Calendar. be energy wise. California Utilities Partnering for Energy Efficiency. California Energy Wise Foodservice Seminars

2013 Spring Calendar. be energy wise. California Utilities Partnering for Energy Efficiency. California Energy Wise Foodservice Seminars California Utilities Partnering for Energy Efficiency 2013 Spring Calendar California Energy Wise Foodservice Seminars Energy-Efficient Equipment Demonstrations be energy wise Informative Educational Seminars

More information

A comparison of the impacts of Euro 6 diesel passenger cars and zero-emission vehicles on urban air quality compliance

A comparison of the impacts of Euro 6 diesel passenger cars and zero-emission vehicles on urban air quality compliance A comparison of the impacts of Euro 6 diesel passenger cars and zero-emission vehicles on urban air quality compliance Introduction A Concawe study aims to determine how real-driving emissions from the

More information

Energy Management Through Peak Shaving and Demand Response: New Opportunities for Energy Savings at Manufacturing and Distribution Facilities

Energy Management Through Peak Shaving and Demand Response: New Opportunities for Energy Savings at Manufacturing and Distribution Facilities Energy Management Through Peak Shaving and Demand Response: New Opportunities for Energy Savings at Manufacturing and Distribution Facilities By: Nasser Kutkut, PhD, DBA Advanced Charging Technologies

More information

This report contains an analysis of the savings which have been achieved as a result of the installation.

This report contains an analysis of the savings which have been achieved as a result of the installation. CASE STUDY Voltage Optimisation The Balmoral Hotel, Edinburgh Introduction A study of the mains voltage profile at the hotel identified that the site was being supplied with excess voltage. Calculations

More information

INCREASING THE ELECTRIC MOTORS EFFICIENCY IN INDUSTRIAL APPLICATIONS

INCREASING THE ELECTRIC MOTORS EFFICIENCY IN INDUSTRIAL APPLICATIONS Institute for Sustainable Energy, UNIVERSITY OF MALTA SUSTAINABLE ENERGY 12: THE ISE ANNUAL CONFERENCE PROCEEDINGS Tuesday 21 February 12, Dolmen Hotel, Qawra, Malta INCREASING THE ELECTRIC MOTORS EFFICIENCY

More information

Final Report. LED Streetlights Market Assessment Study

Final Report. LED Streetlights Market Assessment Study Final Report LED Streetlights Market Assessment Study October 16, 2015 Final Report LED Streetlights Market Assessment Study October 16, 2015 Funded By: Prepared By: Research Into Action, Inc. www.researchintoaction.com

More information

Frymaster Protector Gas Fryer Performance Tests

Frymaster Protector Gas Fryer Performance Tests Frymaster Protector Gas Fryer Performance Tests Application of ASTM Standard Test Method F 1361-05 FSTC Report 5011.08.03 February 2008 Prepared by: Greg Sorensen David Cowen David Zabrowski Fisher-Nickel,

More information

Vulcan-Hart Gas Steamer Performance Testing Model VL2GSS (Pressure) and Model VS3616G (Atmospheric)

Vulcan-Hart Gas Steamer Performance Testing Model VL2GSS (Pressure) and Model VS3616G (Atmospheric) Vulcan-Hart Gas Steamer Performance Testing Model VL2GSS (Pressure) and Model VS3616G (Atmospheric) Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.00.85 Food Service Technology Center

More information

NPCC Natural Gas Disruption Risk Assessment Background. Summer 2017

NPCC Natural Gas Disruption Risk Assessment Background. Summer 2017 Background Reliance on natural gas to produce electricity in Northeast Power Coordinating Council (NPCC) Region has been increasing since 2000. The disruption of natural gas pipeline transportation capability

More information

Analysis of Waste & Recyclable Materials Collection Arrangements. Minnesota Pollution Control Agency Presented by Jeff Schneider

Analysis of Waste & Recyclable Materials Collection Arrangements. Minnesota Pollution Control Agency Presented by Jeff Schneider Analysis of Waste & Recyclable Materials Collection Arrangements Minnesota Pollution Control Agency Presented by Jeff Schneider 4-16-2009 Presentation Topics 1. Purpose of Study & Scope of Work 2. Types

More information

Exhaust Gas CO vs A/F Ratio

Exhaust Gas CO vs A/F Ratio Title: Tuning an LPG Engine using 2-gas and 4-gas analyzers CO for Air/Fuel Ratio, and HC for Combustion Efficiency- Comparison to Lambda & Combustion Efficiency Number: 18 File:S:\Bridge_Analyzers\Customer_Service_Documentation\White_Papers\18_CO

More information

How Much Can a Campus Save on Utility Bills By Turning a 5-Workday Week Into a 4-Workday Week?

How Much Can a Campus Save on Utility Bills By Turning a 5-Workday Week Into a 4-Workday Week? How Much Can a Campus Save on Utility Bills By Turning a 5-Workday Week Into a 4-Workday Week? Jijun Zhou Research Associate Energy System Laboratory Texas A&M University Guanghua Wei, P.E. Assistant Research

More information

Vulcan ER50D Electric Fryer Performance Tests

Vulcan ER50D Electric Fryer Performance Tests Vulcan ER50D Electric Fryer Performance Tests Application of ASTM Standard Test Method F 1361-07 FSTC Report 5011.08.04 December 2008 Prepared by: Greg Sorensen David Cowen David Zabrowski Fisher-Nickel,

More information

V-BELT SOLUTIONS HVAC INDUSTRY

V-BELT SOLUTIONS HVAC INDUSTRY V-BELT SOLUTIONS HVAC INDUSTRY 800-9-608 OPTIBELT-USA.COM HVAC INDUSTRY POWER SOLUTIONS FOR SMALL BUSINESS & RESIDENTIAL LARGE FACILITIES INDUSTRIAL APPLICATIONS AIR CONDITIONERS COOLING TOWERS WHOLE HOUSE

More information

Market Forge, ET-5E Electric Steamer Performance Test

Market Forge, ET-5E Electric Steamer Performance Test Market Forge, ET-5E Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.01.98 Food Service Technology Center Final Report, April 2001 Prepared by: Todd

More information

ITSMR Research Note. Motorcyclists and Impaired Driving ABSTRACT INTRODUCTION KEY FINDINGS. September 2013

ITSMR Research Note. Motorcyclists and Impaired Driving ABSTRACT INTRODUCTION KEY FINDINGS. September 2013 September 2013 KEY FINDINGS F&PI CRASHES INVOLVING IMPAIRED MOTORCYCLISTS 27% of the fatal MC crashes over the five year period, 2008-2012, were alcohol-related. 48% of the alcohol-related F&PI MC crashes

More information

Market Forge, ET-3E Electric Steamer Performance Test

Market Forge, ET-3E Electric Steamer Performance Test Market Forge, ET-3E Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.01.99 Food Service Technology Center Final Report, April 2001 Prepared by: Todd

More information

Portland General Electric Company Eleventh Revision of Sheet No. 7-1 P.U.C. Oregon No. E-18 Canceling Tenth Revision of Sheet No.

Portland General Electric Company Eleventh Revision of Sheet No. 7-1 P.U.C. Oregon No. E-18 Canceling Tenth Revision of Sheet No. Portland General Electric Company Eleventh Revision of Sheet No. 7-1 P.U.C. Oregon No. E-18 Canceling Tenth Revision of Sheet No. 7-1 AVAILABLE In all territory served by the Company. APPLICABLE To Residential

More information

YASKAWA AC Drives. Compressor Applications Application Overview

YASKAWA AC Drives. Compressor Applications Application Overview YASKAWA AC Drives Compressor Applications Application Overview This document provides a general application overview and is intended to familiarize the reader with the benefits of using AC drives in compressor

More information

Energy Efficiency Program Overview

Energy Efficiency Program Overview Energy Efficiency Program Overview Rick Tonielli Sr. Program Manager C O N F I D E N T I A L Who We Are and What We Do Help customers save money and energy Cash incentives Technical services Whole-building

More information

Appendix S. Shared Parking Analysis

Appendix S. Shared Parking Analysis Appendix S Shared Parking Analysis PARKING DEMAND ANALYSIS 2 ND + PCH PROJECT Long Beach, California April 10, 2017 April 10, 2017 Mr. Stephanie Eyestone-Jones Eyestone Environmental 6701 Center Drive

More information

STRYKER VEHICLE ADVANCED PROPULSION WITH ONBOARD POWER

STRYKER VEHICLE ADVANCED PROPULSION WITH ONBOARD POWER 2018 NDIA GROUND VEHICLE SYSTEMS ENGINEERING AND TECHNOLOGY SYMPOSIUM POWER & MOBILITY (P&M) TECHNICAL SESSION AUGUST 7-9, 2018 - NOVI, MICHIGAN STRYKER VEHICLE ADVANCED PROPULSION WITH ONBOARD POWER Kevin

More information

Residential Lighting: Shedding Light on the Remaining Savings Potential in California

Residential Lighting: Shedding Light on the Remaining Savings Potential in California Residential Lighting: Shedding Light on the Remaining Savings Potential in California Kathleen Gaffney, KEMA Inc., Oakland, CA Tyler Mahone, KEMA, Inc., Oakland, CA Alissa Johnson, KEMA, Inc., Oakland,

More information

SOUTHWEST WASTE MANAGEMENT AUTHORITY.

SOUTHWEST WASTE MANAGEMENT AUTHORITY. SOUTHWEST WASTE MANAGEMENT AUTHORITY www.company.com Members Town of Shaunavon Town of Eastend RM of White Valley No. 49 RM of Grassy Creek No. 78 RM of Arlington No. 79 RM of Bone Creek No. 108 History

More information

Data collection and evaluation Lessons learnt Cristina Corchero

Data collection and evaluation Lessons learnt Cristina Corchero Data collection and evaluation Lessons learnt Cristina Corchero Institut de Recerca en Energia de Catalunya Page 0 Green emotion Conference Stockholm, 17th February 2015 Some references Deliverable D1.10

More information

February 2011 Caltrain Annual Passenger Counts Key Findings

February 2011 Caltrain Annual Passenger Counts Key Findings February 2011 Caltrain Annual Passenger Counts Key Findings Key Findings February 2011 Caltrain Annual Passenger Counts The 2011 annual Caltrain passenger counts, which were conducted in February 2011,

More information

Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems

Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems The capture and containment exhaust air flow rates for

More information

GMLC Interoperability Technical Review Meeting Ecosystems Panel

GMLC Interoperability Technical Review Meeting Ecosystems Panel GMLC Interoperability Technical Review Meeting Ecosystems Panel Rich Scholer Fiat Chrysler Automobiles Manager Vehicle to Grid Chair the Hybrid Communication and Interoperability Task Force 1 Index Standards

More information

Food Service Technology Center

Food Service Technology Center Food Service Technology Center Convotherm C4eT 6.20EB Electric Combination Oven Test Report Application of ASTM Standard Test Method F2861-10 May 2015 Prepared by: Denis Livchak Fisher-Nickel, Inc. Contributors:

More information

Optimizing System Performance

Optimizing System Performance Commercial Kitchen Ventilation Optimizing System Performance using Green Tips, Tricks & Technologies from FSTC Research! What can make a hood work better? 9 times out of 10 it is NOT more exhaust! What

More information

Dynamic Pricing: Opportunities & Challenges Harvard Electricity Policy Group September 23, 2011

Dynamic Pricing: Opportunities & Challenges Harvard Electricity Policy Group September 23, 2011 Dynamic Pricing: Opportunities & Challenges Harvard Electricity Policy Group September 23, 2011 Rick Morgan Commissioner Public Service Commission of the District of Columbia 1 A revolution in electricity

More information

How it works How your HAN device helps you monitor electricity use

How it works How your HAN device helps you monitor electricity use How it works How your HAN device helps you monitor electricity use Menu Thursday, September 27 My Home Now 11kW Price Per kwh $ 0.0 7 6:39 pm Falcon Field So Far Today 68.9 kwh 3.6 kw My Cost Per Hour

More information

2015 Carbon footprint JTP. Date of issue: 14 th March 2016

2015 Carbon footprint JTP. Date of issue: 14 th March 2016 2015 Carbon footprint JTP Prepared by: Helen Troup Reviewed by: Sarah McCusker Date of issue: 14 th March 2016 Executive summary Carbon Smart 2 Executive summary JTP have seen significant reduction in

More information

Development of the Micro Combustor

Development of the Micro Combustor Development of the Micro Combustor TAKAHASHI Katsuyoshi : Advanced Technology Department, Research & Engineering Division, Aero-Engine & Space Operations KATO Soichiro : Doctor of Engineering, Heat & Fluid

More information

Energy Efficiency Benefits

Energy Efficiency Benefits Energy Efficiency Benefits Heating and Cooling Energy Conservation Case Study 40 W 20 th Street, NRDC New York Headquarters October 2016 Authors Ryan Meinke Anthony Guerrero Contributors Milly Suarez Eileen

More information

Impact of Distributed Energy-Efficiency with Solar on SMUD s Peak Load

Impact of Distributed Energy-Efficiency with Solar on SMUD s Peak Load Impact of Distributed Energy-Efficiency with Solar on SMUD s Peak Load Mike Keesee, Sacramento Municipal Utility District Rob Hammon, ConSol ABSTRACT One of the advertised benefits of distributed solar

More information

Accelerated Life Testing Final Report

Accelerated Life Testing Final Report Accelerated Life Testing Final Report November 6, 2006 Prepared by the, Project team: Lalith Jayasinghe, Conan O Rourke, Mariana Figueiro Background During the review process of the ENERGY STAR Light Fixture

More information

Ultrafryer Basic Low Oil Level Model E3EX-14 With 8 Vat Operation Instructions for Remote U-23 with Auxiliary Controls

Ultrafryer Basic Low Oil Level Model E3EX-14 With 8 Vat Operation Instructions for Remote U-23 with Auxiliary Controls Ultrafryer Basic Low Oil Level Model E3EX-14 With 8 Vat Operation Instructions for Remote U-23 with Auxiliary Controls PN 30A254 TABLE OF CONTENTS Page Preface 3 Fryer & Components 4 5 Overview Control

More information

Frymaster 22 kw Protector Electric Fryer Performance Tests

Frymaster 22 kw Protector Electric Fryer Performance Tests Frymaster 22 kw Protector Electric Fryer Performance Tests Application of ASTM Standard Test Method F 1361-05 FSTC Report 5011.08.11 May 2008 Prepared by: David Cowen David Zabrowski Fisher-Nickel, Inc.

More information

Seven Springs Mountain Resort: August 4-7, RIDE EM DON T HIDE EM

Seven Springs Mountain Resort: August 4-7, RIDE EM DON T HIDE EM Seven Springs Mountain Resort: August 4-7, 2017. RIDE EM DON T HIDE EM Is it because we re getting older? For some reason, only Nick Pechin from Hawaii signed up to ride back and forth across the state.

More information

DC Power Grid System Lighting for a Typical Conference Room Evaluation

DC Power Grid System Lighting for a Typical Conference Room Evaluation Design & Engineering Services DC Power Grid System Lighting for a Typical Conference Room Evaluation ETO 09.03 Report Prepared by: Design & Engineering Services Customer Service Business Unit Southern

More information

Ultrafryer Low Oil Level Model E3RL-14/8 Operation Instructions for Remote U-23 with Auxiliary Controls

Ultrafryer Low Oil Level Model E3RL-14/8 Operation Instructions for Remote U-23 with Auxiliary Controls Ultrafryer Low Oil Level Model E3RL-14/8 Operation Instructions for Remote U-23 with Auxiliary Controls PN 30A245 rev A TABLE OF CONTENTS Page Preface 3 Recommended Spare Parts 4 Fryer Specifications 5

More information

ARISEIA Energy Forum APS Residential Rate Design

ARISEIA Energy Forum APS Residential Rate Design ARISEIA Energy Forum APS Residential Rate Design A Brief History and What s Next for Arizona? November 7, 2015 Leland Snook Director, Rates and Rate Strategy Arizona Public Service Company Arizona s largest

More information

Alberta Speeding Convictions and Collisions Involving Unsafe Speed

Alberta Speeding Convictions and Collisions Involving Unsafe Speed Alberta Speeding Convictions and Collisions Involving Unsafe Speed 2004-2008 Overview This document was prepared under the Alberta Traffic Safety Plan, Strategic Research Plan for 2008-2010, with the objective

More information

Smart Grids from the perspective of consumers IEA DSM Workshop

Smart Grids from the perspective of consumers IEA DSM Workshop Smart Grids from the perspective of consumers IEA DSM Workshop 14 th November 2012 Linda Hull EA Technology Overview What is a smart grid? What do customers know about Smart Grids What do they know about

More information

Bloomberry sustains turnaround story P5.7 billion swing leads to P2.2 billion net profit

Bloomberry sustains turnaround story P5.7 billion swing leads to P2.2 billion net profit Bloomberry sustains turnaround story P5.7 billion swing leads to P2.2 billion net profit Highlights: Solaire achieved record gaming volumes and revenues Solaire s VIP volumes grew 29 percent, while mass

More information

IMPACT OF GASOLINE PRICES ON LAS VEGAS VISITATION FROM SOUTHERN CALIFORNIA AND LAS VEGAS LOCALS

IMPACT OF GASOLINE PRICES ON LAS VEGAS VISITATION FROM SOUTHERN CALIFORNIA AND LAS VEGAS LOCALS Monday, June 30, 2008 IMPACT OF GASOLINE PRICES ON LAS VEGAS VISITATION FROM SOUTHERN CALIFORNIA AND LAS VEGAS LOCALS Executive Summary There is a direct correlation between rising gas prices and reduced

More information

Solar and Smart Meter Update. 1 April 2014 to 30 June 2014 Released July 2014

Solar and Smart Meter Update. 1 April 2014 to 30 June 2014 Released July 2014 Solar and Smart Meter Update 1 April 2014 to 30 June 2014 Released July 2014 2 CONTENTS 1. Solar and Smart Meter Cases... 3 2. SMART METER UPDATE... 4 2.1. EWOV Smart Meter Cases Increase by 36%... 4 2.2.

More information

THE REAL-WORLD SMART CHARGING TRIAL WHAT WE VE LEARNT SO FAR

THE REAL-WORLD SMART CHARGING TRIAL WHAT WE VE LEARNT SO FAR THE REAL-WORLD SMART CHARGING TRIAL WHAT WE VE LEARNT SO FAR ELECTRIC NATION INTRODUCTION TO ELECTRIC NATION The growth of electric vehicles (EVs) presents a new challenge for the UK s electricity transmission

More information

BROWARD BOULEVARD CORRIDOR TRANSIT STUDY

BROWARD BOULEVARD CORRIDOR TRANSIT STUDY BROWARD BOULEVARD CORRIDOR TRANSIT STUDY FM # 42802411201 EXECUTIVE SUMMARY July 2012 GOBROWARD Broward Boulevard Corridor Transit Study FM # 42802411201 Executive Summary Prepared For: Ms. Khalilah Ffrench,

More information

9 Secrets to Cut Fleet Costs

9 Secrets to Cut Fleet Costs ebook 9 Secrets to Cut Fleet Costs GPS fleet tracking can help improve productivity and reduce fuel usage, which can lead to increased revenue and better customer service. The day-to-day costs of running

More information

Edison s s Bright Idea:

Edison s s Bright Idea: Edison s s Bright Idea: Mental Models, Heuristics, Strategies of Invention, and the Electric Light Gary Bradshaw Psychology Department Mississippi State University This work has been supported by Gary

More information

The fact that SkyToll is able to deliver quality results has been proven by its successful projects.

The fact that SkyToll is able to deliver quality results has been proven by its successful projects. www.skytoll.com At present, an efficient and well-functioning transport sector and the quality of transport infrastructure itself are a prerequisite for the further growth of the economy and ensure the

More information

Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems

Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems The capture and containment exhaust air flow rates for

More information

RULE EMISSIONS OF OXIDES OF NITROGEN FROM SMALL INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS HEATERS

RULE EMISSIONS OF OXIDES OF NITROGEN FROM SMALL INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS HEATERS RULE 1146.1. EMISSIONS OF OXIDES OF NITROGEN FROM SMALL INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (a) Definitions 1. ANNUAL HEAT INPUT means the actual amount

More information

National Household Travel Survey Add-On Use in the Des Moines, Iowa, Metropolitan Area

National Household Travel Survey Add-On Use in the Des Moines, Iowa, Metropolitan Area National Household Travel Survey Add-On Use in the Des Moines, Iowa, Metropolitan Area Presentation to the Transportation Research Board s National Household Travel Survey Conference: Data for Understanding

More information

Montana State University: Solar Cells Lecture 9: PV Systems. Montana State University: Solar Cells Lecture 9: PV Systems

Montana State University: Solar Cells Lecture 9: PV Systems. Montana State University: Solar Cells Lecture 9: PV Systems EE580 Solar Cells Todd J. Kaiser Lecture 09 Photovoltaic Systems Several types of operating modes Centralized power plant Large PV system located in an optimum location, feeding into the grid Distributed

More information

Synthesis of Optimal Batch Distillation Sequences

Synthesis of Optimal Batch Distillation Sequences Presented at the World Batch Forum North American Conference Woodcliff Lake, NJ April 7-10, 2002 107 S. Southgate Drive Chandler, Arizona 85226-3222 480-893-8803 Fax 480-893-7775 E-mail: info@wbf.org www.wbf.org

More information

M Resort Spa Casino. Tom Chirdon. Faculty Advisor: William P. Bahnfleth Spring 2009

M Resort Spa Casino. Tom Chirdon. Faculty Advisor: William P. Bahnfleth Spring 2009 M Resort Spa Casino Tom Chirdon Faculty Advisor: William P. Bahnfleth Spring 2009 Project Background Project Cost : $1 Billion Ground Breaking: Spring 2007 Opened: March 1, 2009 Owner: Marnell Corrao

More information

Shipboard Testing of B20

Shipboard Testing of B20 Shipboard Testing of B20 Final Report Daniel N. Pope Richard D. Ricketts Department of Mechanical and Industrial Engineering University of Minnesota Duluth Large Lakes Observatory University of Minnesota

More information

Key Findings. February 2009 Caltrain Annual Passenger Counts

Key Findings. February 2009 Caltrain Annual Passenger Counts Key Findings February 2009 Caltrain Annual Passenger Counts The 2009 annual Caltrain passenger counts, which were conducted starting in late-january and were complete by mid-february, followed the same

More information

COMPANY INTRO. PowerCore Engineering

COMPANY INTRO. PowerCore Engineering PowerCore Engineering COMPANY INTRO PowerCore is a Power Distribution System Engineering Company and a turnkey Automated Systems Integrator based in London Ontario. We specialize in Power Systems Engineering

More information

ACS-2 Long and Short Term Endurance Indicators

ACS-2 Long and Short Term Endurance Indicators ACS-2 Long and Short Term Endurance Indicators February 13, 2009 Revision 0 Technical Editor: Jim Hatfield 389 Disc Drive Longmont, CO 80503 720-684-2120 James.C.Hatfield@Seagate.com Long and Short Term

More information

Liquefied Natural Gas (LNG) Yard Hostler Demonstration and Commercialization Project

Liquefied Natural Gas (LNG) Yard Hostler Demonstration and Commercialization Project Liquefied Natural Gas (LNG) Yard Hostler Demonstration and Commercialization Project Project Team Port of Long Beach Sound Energy Solutions WestStart-CALSTART Long Beach Container Terminal, Inc. United

More information

February 2012 Caltrain Annual Passenger Counts Key Findings

February 2012 Caltrain Annual Passenger Counts Key Findings February 2012 Caltrain Annual Passenger Counts Key Findings Key Findings February 2012 Caltrain Annual Passenger Counts The 2012 annual Caltrain passenger counts, which were conducted in February 2012,

More information

Example 1MW Solar System for Fosters Yatala

Example 1MW Solar System for Fosters Yatala Example 1MW Solar System for Fosters Yatala Document Created by Luke M Hardy lmhardy@smartconsult.com.au Smartcom P/L 31 December 2012 Highlights Luke M Hardy MBA, Grad Cert Carbon Management Key Points

More information

Assessing fuel efficiency and CO 2 emissions of two local food distribution options in Iowa

Assessing fuel efficiency and CO 2 emissions of two local food distribution options in Iowa Assessing fuel efficiency and CO 2 emissions of two local food distribution options in Iowa Rich Pirog, Associate Director, Leopold Center for Sustainable Agriculture Rebecca Rasmussen, Graduate Student,

More information

Field Verification and Data Analysis of High PV Penetration Impacts on Distribution Systems

Field Verification and Data Analysis of High PV Penetration Impacts on Distribution Systems Field Verification and Data Analysis of High PV Penetration Impacts on Distribution Systems Farid Katiraei *, Barry Mather **, Ahmadreza Momeni *, Li Yu *, and Gerardo Sanchez * * Quanta Technology, Raleigh,

More information

Group 3: Pricing from 1 April 2018 and load management

Group 3: Pricing from 1 April 2018 and load management Group 3: Pricing from 1 April 2018 and load management This document is intended to provide background to Network Tasman s Group 3 pricing, in particular the Regional Coincident Peak Demand (RCPD) price,

More information

Ketchum Energy Advisory Committee Annual Update and Recommendation for Electric Vehicle Charging Station

Ketchum Energy Advisory Committee Annual Update and Recommendation for Electric Vehicle Charging Station March 21, 2016 Mayor Jonas and City Councilors City of Ketchum Ketchum, Idaho Mayor Jonas and City Councilors: Ketchum Energy Advisory Committee Annual Update and Recommendation for Electric Vehicle Charging

More information

Chapter 6. Supercharging

Chapter 6. Supercharging SHROFF S. R. ROTARY INSTITUTE OF CHEMICAL TECHNOLOGY (SRICT) DEPARTMENT OF MECHANICAL ENGINEERING. Chapter 6. Supercharging Subject: Internal Combustion Engine 1 Outline Chapter 6. Supercharging 6.1 Need

More information

APPENDIX TR-1 PARKING AND QUEUING ASSESSMENT

APPENDIX TR-1 PARKING AND QUEUING ASSESSMENT APPENDIX TR-1 PARKING AND QUEUING ASSESSMENT Overland Overland Traffic Consultants, Traffic Consultants, Inc. Inc. Overland Traffic Consultants 952 Manhattan Beach Boulevard, Suite #100 Manhattan Beach,

More information

Aerodynamic device vortex generators

Aerodynamic device vortex generators Aerodynamic device vortex generators TRIAL SUMMARY This trial sought to quantify the fuel efficiency benefit of an aftermarket device fitted to trailers to reduce aerodynamic drag. The trial was conducted

More information

Designation of a Community Safety Zone in Honey Harbour in the Township of Georgian Bay

Designation of a Community Safety Zone in Honey Harbour in the Township of Georgian Bay TO: FROM: Chair and Members Engineering and Public Works Committee Mark Misko, C.E.T. Manager, Roads Maintenance and Construction DATE: March 23, 2016 SUBJECT: REPORT NO: Designation of a Community Safety

More information

Introduction: Supplied to 360 Test Labs... Battery packs as follows:

Introduction: Supplied to 360 Test Labs... Battery packs as follows: 2007 Introduction: 360 Test Labs has been retained to measure the lifetime of four different types of battery packs when connected to a typical LCD Point-Of-Purchase display (e.g., 5.5 with cycling LED

More information

Cleveland Range Inc., SteamCraft Ultra 3 Electric Steamer Performance Test

Cleveland Range Inc., SteamCraft Ultra 3 Electric Steamer Performance Test Cleveland Range Inc., SteamCraft Ultra 3 Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.00.84 Food Service Technology Center Final Report, November

More information

Investigation of Relationship between Fuel Economy and Owner Satisfaction

Investigation of Relationship between Fuel Economy and Owner Satisfaction Investigation of Relationship between Fuel Economy and Owner Satisfaction June 2016 Malcolm Hazel, Consultant Michael S. Saccucci, Keith Newsom-Stewart, Martin Romm, Consumer Reports Introduction This

More information