DIE AND COLOR CODE INFORMATION -1 B ~ Fig. 1. Installation Tooling Stud Figure Mechanical Hvdraulic Wire ~ W8CVT (1) W8CVT (1)
|
|
- Jared Hopkins
- 5 years ago
- Views:
Transcription
1 ' TYPES YA-L, YA-L-FX, YAV, YAV-L-FX '.COPPER COMPRESSON TERMNAL DE AND COLOR CODE NFORMATON NSPECTON WNDOW ----:;;{'l BEVELED ENTRY,,'"' CABLE ACCOMMODATON : UL Listed 90 0 C, 600 Volts to 35 KV 9 - B j' L-..L Fig. Fig. 2!d Fig.3 nstallation Tooling Stud Figure Mechanical Hvdraulic Wire Hole Tongue Dimensions Dieless MDS, OUR840, BCT500HS, Y35, Y39, Y750, Color Die Strip Catalog Number Fig# AWG MM 2 Size Width (Bl (T) (L) (# of crimps) MD7 34R Y500CTHS Y4S', BAT750 Code ndex Length YABCL-BOX YABCL ,4",44".08" YABCL " YABC L BOX YABC-L-45 2 /4",44".44".08".24" YABC L /24 YMR () YABC L2 BOX.. W8CVT () W8CVT () Y8MRB YABC-L #8 Weld 5/6".52",44".08" W8CRT () W8CRT () U8CRT () Red 49 7/6" Y2MR () VABC-L " X8CRT () X8CRT () MY29- () YABC L3 BOX #8AWG.l: J.:.. YABC-L /8".58".44".08" YABC L " YABC-L4-BOX YABC-L /2".7",44".08" YABC-L " YAV6CL TC0 FX YAV6CL TC0 FX ,48".50".08" YAV6CL-TC0 FX " YAV6CL TC2 FX YAV6CL TC2 FX 45 2 /2".75".50".2".92" VAV6CL TC2 FX /24 YMR () YAV6CL TC4 FX.. W5CVT () W5CVT () YAV6CL TC4 FX 45 2 #6 WELD /4',48".50".08" Y2MR () W5CRT () W5CRT () U5CRT () Blue 7 /2" MY29- () YAV6CL TC4 FX " X5CRT () X5CRT () YAV6CL-TC38 FX f #6AWG.6" YAV6CL TC3B-FX /8".60".50".06" r--=-'- YAV6CL-TC3B FX ' YAV6CL TC56-FX YAV6CL TC56 FX /6".60".50" 0.07".44" YAV6CL-TC56 FX ' Use PUADP- adapter with "U" dies in Y46 HYPRESS'M. H The MM2 conductor size listed is lor both Class 2 and Class 5 conductors. The MM2 conductor sizes listed are the recommendations tor Class 5conductor.. See tooling section of this catalog lor complete tool and die listings. Use ONLY color-coded die recommendations for '-FX" connectors. For nesvindentor system contact lactory. For applications greater than 2000 Volts consult cable manufacturer lor voltage stress relief instructions.
2 (Continued) g ::::JLF=L ( ' Fig. Fig. 2 Fig. 3.., nstallation Toolino Stud Figure Mechanical Hydraulic Wire..- Hole Tongue Dimensions Dieless MD6, OUR840, 8CT500HS, Y35,Y39, Y750, Color Die Strip Catalog Number Flo # AWG MM2 Size Width (8) m (Ll (# of crimosl MD7 34R Y500CTHS Y46', SAmO Code ndex Lenalh YAV6CL TC34 FX " Y2MR () YAV6CL TC34 FX 45 2 #6 WELD 34".05".50".3" 2 39" MY29 () W5CVT() X5CRT () U5CRT () Blue 7 2" 6 YAV6CL TC34 FX 90 3 #6 AWG,78" YAV4CL TC0 FX YAV4CL TC0 FX ".SO".09".30" YAV4CL TC0 FX 90 3 YAV4CL TC2 FX.92" f-- YAV4CL TC2 FX ".7".SO".0".84" YAV4CL TC2 FX 90 3 YAV4CL TC4 FX 0S24.44" W4CVT () W4CVT () YAV4CL TC4 FX ".SS".50".09" W W4CRT () W4CRT () U4CRT () Gray 8 2" YAV4CL TC4 FX 90 3 #4 WELD.92" X4CRT () X4CRT () YAV4CL TC38 FX.67" YAV4CL TC38 FX 45 2 #4AWG 38".S8".SO".08".63" f-- YAV4CL TC38 FX " YAV4CL TC56 FX YAV4CL TC56 FX 45 2 S6".SS".SO".09",49" YMR (2) YAV4CL TC56 FX 90 3 Y2MR (2) YAV2CL TC0 FX.S0" MY29 () YAV2CL TC O FX 45 # 0.68".63".0" YAV2CL TC0 FX YAV2CL TC2 FX 2,2" YAV2CL TC2 FX 45 2S24 2".77".63" 0.09 YAV2CL TC2 FX 90.40" YAV2CL TC4 FX S0/24.62" W2CVT () W2CVT () YAV2CL TC4 FX S 4".68".63".0" l.s8" W2CRT () W2CRT () U2CRT () Brown 0 6" YAV2CL TC4 FX 90 3 #2 WELD.97" X2CRT () X2CRT () YAV2CL TC38 FX.8" YAV2CL TC38 FX 45 2 #2 AWG 38".68".63.0" "t7r YAV2CL TC38 FX 90 3 YAV2CL TC56 FX.69" YAV2CL TC56 FX 45 2 S6".68".63".0" '.65" YAV2CL TC56 FX 90 3,03" YAVCL TC0 FX.S9" YAV CL TC0 FX 45 2 #0.7S".69".2" :,S6" YAVCL TC0 FX " YAVCL TC2 FX 3 2.S" YAVCL TC2 FX S24 2".7S".69".2" 2,2" YAVCL TC2 FX 90 3 YAVCL TC4 FX 2 22S/24.7" WCVT() WCVT() MY29 () YAV CL TC4 FX ".7S".69".2".69" WCRT- () WCRT j () UCRT () Green 6" YAVCL TC4 FX 90 3 # WELD.00" XCRT- () XCRT- (). YAVCL TC38 FX.90" YAV CL TC38 FX 45 2 # AWG 38".7S".69".2".87" YAVCL TC38 FX " YAVCL TC56 FX.78" YAV CL TC56 FX 45 2 S6".7S".69".2".75" YAV CL TC56 FX " Use PUADP adapter with "U" dies in Y46 HYPRESSTM.. The 6 MM2 is for both Class 2 and Class 5 conductors. h The MW conductor sizes listed are the recommendations for Class 5 conductor, See toofing secuon ollh scata lor complete tool and die listings. Use ONLY coor-coded die recommendauons for " FX" connectors. For nestjindentorsystem coniacllactory. For applications greater than 2000 ValS consult cable manufacturer for voltage stress rellellnslrucliclos.
3 Compression ----"_""":>-"':..J..-_-=:'-,"-,-=_..,Jo.--' (Continued) Fig. Fig, 2 Fig. 3 A nstallation Toolina Stud Figure Mechanical Hydraulic Wire Hole Tongue Dimensions Oieless M06, OUR840, BCT500HS, Y35, Y39, Y750, Color Die Strip Cataloa Number Fig # AWG MM 2 Size Width (Bl m (Ll (# 0 crimos) MD7-34R Y500CTHS Y46' SAT750 Code ndex Lenalh YAV25L TC2 FX YAV25L TC2 FX 45 2 /2",83".69",2" 2.5" YAV25L TC2 FX 90 3 W YAV25L TC4 FX.75" 275/24 YAV25L TC4 FX-45 2 /4".83".69".2" " W25VT (2) W25VT (2) YAV25L TC4 FX 90 3 W25RT (2) W25RT (2) U25RT () Pnk 2 /6" /0 WELD 50 YAV25L TC38 FX.94/' X25RT (2) X25RT (2) YAV25L TC38 FX /8",83".69",2" 90- ;.:.:.:.. /0AWG YAV25L TC38 FX 90 3,22" YAV25L TC56 FX YAV25L TC56 FX /6".83".69",2".77" YAV25L TC56 FX 90 3 "".69" YAV26L TC0 FX YAV26L TC0 FX ,93",8".3'".73" YAV26L TC0 FX 90 3 M YAV26L TC2 FX, 2,36" YAV26L TC2 FX 45 2 /2".93'.8".3" YAV26L TC2 FX " YAV26L TC4 FX.92" YAV26L TC4 FX 45 2 /4".93",8".3" :85" YAV26L TC4-FX /24 :07" YAV26L TC34 FX 2,89" W26VT (2) W26VT (2) YAV26L TC34 FX /0 WELD 70 3/4".0".8"./ "2.7s" W26RT (2) W26RT (2) YAV26L TC34 FX 90 3 :93" MY29 () X26RT (2) X26RT (2) U26RT () Black 3 3/6" YAV26L TC38 FX 2/0AWG 2." YAV26L TC38 FX /8".93".8",3" "2:Q;r YAV26L TC38 FX 90 3 ".26" YAV26L TC56 FX.98" YAV26L TC56 FX /6",93",8".3" ".92" YAV26L TC56 FX 90 3 YAV26L TC58 FX 2.6" YAV26L TC58 FX 45 5/8",93",8".3"..=.:..::..; 2""54" YAV26L TC58 FX 90.76" YAV27L TC0 FX YAV27L TC0 FX 45 2 / 0.03".00.4".9" YAV27L TC0 FX 90 3 YAV27L TC2 FX 2.59" YAV27L TC2 FX 45 2 /2".03".00",4" 2.47" YAV27L TC2 FX /24.54" YAV27L TC4 FX 2.5" W27VT (2) W27VT (2) YAV27L TC4 FX /0 WELD 95 /4".03".00",4" : 2.04" W27RT (2) W27RT (2) U27RT () Orange 4 H YAV27L TC4 FX " X27RT (3) X27RT (3) YAV27L TC38 FX 3/0AWG 2.34" YAV27L TC38 FX /8".03".00 H.4" 2.22" YAV27L TC38 FX " YAV27L TC56 FX 2.2" YAV27L TC56 FX /6".03".00'.4 H 2,0" YAV27L TC56 FX ', Use PUADp, adapter with "U" dies in Y46 HYPRESSTM See tooling section of this catal09 for complete 00 and die." The MM2 conduclor sizes listed are the recommendations listings, Use ONLY color-coded die recommendations for for Class 5conductor. " FX'" connectors. For nesvindentor system contact factory. Forappllcatlons grealer than 2000 Volls consult cable manufacturer for voltage stress relief instructions.
4 ..,,. & - B f-?, c=j TL J (Continued) Fig. Fig. 2 Fig. 3.. nstatation Tooling Stud Figure Mechanical Hvdraulic Wire Hole Tongue Dimensions Dieless MDS,OUR840, BCT500HS, Y35, Y39, Y750, Color Die Strip Cataloo Number Flo # AWG MM 2 Size Width (B) m (L 0 crillls) MD7 34R Y500CTHS Y4S' BAT750 Code ndex Lenoth YAV28L TCt2 FX YAV28l TC2 FX 45 2 /2".4".03" " YAV28L TC2 FX ,5S" YAV28l TC4 FX 2.23" -- YAV28L TC4 FX 45 2 /4".4".03".5" 2." YAV28L TC4 FX 90 3 YAV28L TC34 FX 3." 550/24 YAV28l TC34 FX /4".4".03".5" '2.98" W2SVT (2) W2SVT (2) YAV28l TC34 FX 90 3 " '2.02" MY29- () 4/0 WELD YAV28l TC38 FX 20 W2SRT (2) W2SRT (2) X2SRT (2) X2SRT (3) YAV28l TC38 FX /S".4".03".5" 2.29" 4/0 AWG '--- YAV28l TC38 FX " U2SRT () Purple 5 -/6" YAV28l TC56 FX " '--- YAV28L TC56 FX /6".4".03".5" 2.7" YAV28L TC56 FX 90 3 YAV28l TC58 FX 2.92" YAV28l TC58 FX /S".4".03".5" 2.79" YAV28l TC58 FX 90 3 YAV29l TC2 FX 2.67" YAV29L TC2 FX 45 2 /2".4".03".6" VAV29L TC2 FX 90 3 YAV29L TC4 FX YAV29L TC4 FX ".4".03".6" YAV29L TC4 FX " YAV29L TC34 FX VAV29l TC34 FX /24 34'.4".03".6" 2.9S" YAV29l TC34 FX 90 3 '2:02" VAV29l TC38 FX 2.42" YAV29l TC38 FX /0 WELD 3/S".4".03".6" 2.29" YAV29l TC38 FX " VAV29l TC56 FX " YAV29l TC5S FX /6".4".03".6" YAV29l TC56 FX 90 3 W29VT (2) VAV29l TC58 FX 2.92" X29RT (4) YAV29l TC58 FX /S".4".03".6" 2.79" YAV29l TC58 FX 90 3.S3" YA30l TC56 FX 2.3" YA30l TC5S FX /6".20".03".6" 2.22" YA30L TC56 FX FLEX YA30l TC38 FX 2.44" VA30l TC38 FX /S".20".03".6" CLASS G VA30l TC38 FX STR.. -- YA30l TC2 FX 2.69" YA30l TC2 FX 45 2 /2".20".03".6'" 2.60" YA30l TC2 FX 90 3 CLASS H.6" YA30l TC58 FX 427 STR. 2.94" YA30l TC58 FX /S'.20".03",6'" 2.S5" VA30l TC58 FX 90 3 W29VT (2) W29RT (2) U29RT () Yellow 6 /6" X29RT (4), Use PUADP- adapter with "U" dies in Y46 HYPRESSTM u The 20 MM2 referenced here is lor both Class 2 and Class 5. u. The MM2 conductor sizes listed are the recommendations lor Class 5 conductor... See looling section of this catalog (or complete tool and die listings. Use ONLY color coded die recommendations for " FX" connectors. For nesvindentor system contact factory. For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions.
5 308 '""'" " ;- rblifnjd, '-- Gompression t :' ", (Continued) A g ( L Fig. Fig. 2 Fig. 3 : nstallation Toollna Stud Figure Mechanical Hydraufic Wire.., Hole Tongue Dimensions Dieless M06, OUR840, BCT500HS, Y35, Y39, Y750, Color Die Strip Cataloo Number Flo # AWG MM 2 Size Width rb\ m (# 0 crimps) MD7 34R Y500CTHS Y46' BAmO Code ndex Lenoth VA30L TC34 FX 250 FLEX 3.2" X29RT (4) W29VT (2) VA30L TC34 FX 45 2 CLASS G259 sm. 3/4".20".03".6" 304" W29VT (2) U29RT () Yellow 6 6" X29RT (4) YA30L TC34 FX 90 3 CLASS sm 2.05" W29RT (2) YA3L TC4 FX 2.3" YA3L TC4 FX 45 2 /4".29".06".8" 2.23" VA3L TCl4-FX " t YA3L TC56 FX 2.37" VA3 L TC56 FX /6".29".06".8" : 2.30" YA3 L TC56 FX " VA3L TC38 FX 2.50" YA3L TC38 FX ".29".06'.8" 2.42" VA3 L TC38 FX FLEX.40" VA3 L NT2 FX!i 2.75" W30VT (2) VA3 L NT2 FX /24 50 /2".96".06".8" 2.67" W30VT (2) U30RT (2) While 7 /8" W30RT (2) YA3 L NT2 FX " ru YA3L TC2 FX CLASS, K, M 2.75" YA3 L TC2 FX 45 2 /2".29".06".8" 2.67" f :J VA3 L TC2 FX ". YA3 L TC58 FX 3.00" YA3L TC58 FX /8".29".06".8" YA3 L TC58 FX " VA3 L TC34 FX 3.9" r YA3 L TC34 FX /4".29".06".8" VA3 L TC34 FX " h YA32L TC38 FX 2.68" VA32L TC38 FX /8".40".9".9" 2.58" VA32L TC38 FX KCML, W YA32L TC2 FX 293" YA32L TC2 FX / ".40".9".9" 2.83" W3VT (2) W3VT (2) U3RT (2) Red 8 /4" W3RT (2) YA32L TC2 FX 90 3 YA32L TC58 FX 300 FLEX 3.8" ; YA32L TC58 FX ".40".9".9" " YA32L TC58 FX " YA34L TC56 FX 2.74" YA34L TC56 FX /6".55".27".23" 2.68" --- YA34L TC56 FX " r YA34L TC38 FX KCML 2.87" YA34L TC38 FX 45 2 f" 38".55".27".23" 2.80" YA34L TC38 FX / '.53" W32VT (2) W32VT (2) U32RT (2) Blue 9 56" r :: VA34L TC2 FX 3.2" W32RT (2) VA34L TC2 FX ".55".27".23" 3.05" ;'. 350 FLEX YA34L TC2 FX " YA34L TC58 FX 3.37" YA34L TC58 FX /8".55".27",23" : 3.30" YA34L TC58 FX " YA36L TC2 FX KCML 3.29" YA36L TC2 FX 45 2 /2".74",38".27" 3.26'- 450 FLEX YA36L TC2 FX ". U34RT (2) Brown 20 3/8" Use PUADP l adapter with 'U" dies in Y46 HYPRESS'" The MM2 conductor sizes listed are the recommendations lor Class 5 conductor. See looling section of this calalog lor complete tool and die listings. Use ONLY color coded die recommendations lor " FX connectors. For nesvindentor system contact faclory. For applications greater than 2000 Volls consult cable manufacturer lor voltage stress reliel instructions..,..,.:!l'li
6 BURNDY Compression..\ " (Continued) (, C L- Fig. Fig. 2 Fig. 3 nstallation Toolino Stud Figure MecbanicaJ Hvdraullc Wire.., Hole Tongue Dimensions Dieless MD6, OUR840, BCT500HS, Y35, Y39, Y750, Color Die Strip Catalog Number Flo # AWG MM 2 Size Width B m Ll (# of crimosl MD7 34R Y500CTHS Y46' BAT750 Code ndex Lenalb VA36L TC5B FX 3.54" VA36L TC5B FX ".74".38",27" 35" U34RT (2) Brown 20 38" VA36L TC58 FX 90 3 VA38L TC2 FX 3.4" --- VA38L TC2 FX 45 2 /2".84".45".27" 3.35" VA38L-TC2-FX " VA38L TC58 FX 3.66" 535,3 KCML VA38L TC58 FX ",84".45".27" 3.60" VA38L TC58 FX " 325/ VA38L-TC56 FX 3 03" U38XRT (2) Pink L99-7/6" VA38L TC56 FX ".84".45".27" 2.97" 500 FLEX ---- VA38L TC56 FX " VA38L TC38 FX 3.34" VA38L TC3B FX /8".84".45".27" 3.29" VA3BL TCSB FX 90 3 VA40L TC56 FX 3 05" VA40L TC56 FX /6".98".42".30" 3.06" VA40L TC56 FX " VA40L TC3B FX 3.38" YA40L TC3B FX ".98".42".30" 3,38" 646 KCML VA40L TC3B FX U39RT (2) Black 24-56" YA40L TC2 FX 3.43" 600/24 VA40L TC2-FX 45 2 /2".98".42".30" 344" VA40L TC2 FX " VA40L TC5B FX 3.68" VA40L TC5B FX /8".98".42".30" 3 69" VA40L TC5B FX 90 3 r-m YA44L TC2 FX 3.79" YA44L TC2 FX 45 2 /2" 2.9",65".33" 3.76" YA44L TC2 FX KCML W 500. U44XRT (2) Yellow L5-5/8" VA44L TC5B FX 925/ " YA44L TC5B FX " 2.9".65".33" "4.0" VA44L TC5B FX 90 3 Use PUADP- adapter with 'U' dies in Y46 HYPRESSTM The MM2 conductor sizes listed are the recommendations for Class 5conductor. See tooling section of this catalog lor complete tool and die lislings. Use ONLY color coded die recommendalions for "-FX" connectors. For nestlindentor system contact factory, For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions,
BURNDY Compression. TWO HOLE HYLUG CODE CONDUCTOR STANDARD BARREL (Continued) Fig. 1 Fig. 2 Fig. 3. Conductor
URNDY TWO HOLE HYLUG CODE CONDUCTOR STANDARD ARREL (Continued) T T T Fig. 1 Fig. 2 Fig. 3 C-46 Conductor Installation Tooling Stud Stud Figure Mechanical Hydraulic Wire Fig *** Hole Hole Tongue Dimensions
More informationB T T T 2.11 MY29-11 (1) 4/0 AWG - MY29-11 (1) W30VT (2) U30RT (2) 300 kcmil 150 W30VT (2) YA30L-2TC W30RT (2) U28ART (2)
URNDY TWO HOLE HYLUG CODE CONDUCTOR STANDARD ARREL (Continued) T T T Fig. 1 Fig. 2 Fig. 3 Conductor Installation Tooling Stud Stud Figure Mechanical Hydraulic Wire Fig *** Hole Hole Tongue Dimensions Dieless
More informationWind Energy Catalog Solutions for the Wind Industry
RenewableConnections Wind Energy Catalog Solutions for the Wind Industry TM Experience. Technology. Answers. Why Choose BURNDY Experience. Technology. Answers ṬM As the wind industry has grown so has our
More informationQuick Term II. Cold Shrink Silicone Rubber Termination. Quick Term II. Instruction Sheet
Quick Term II Cold Shrink Silicone Rubber Termination Instruction Sheet IEEE Std. No. 48 1990 Class 1 Termination 15 kv Class 110 kv BIL Kit Contents: 1 Hi K Silicone Rubber Termination 2 Scotch 70 Silicone
More informationCP 600V Cable Protectors
Protecrs Mersen CP Protecrs are special purpose limiters which are crimped or bolted cables or terminals clear and isolate faults quickly, increasing the reliability of service entrance and distribution
More informationInstructions. Quick Term II 2047MT 56. 3M Quick Term II. Silicone Rubber Termination (with High-K Stress Relief)
Instructions Quick Term II Silicone Rubber Termination (with High-K Stress Relief) IEEE Std. No. 48 990 Class Termination 5 kv Class 50 kv BIL Kit Contents Hi K Silicone Rubber Termination Scotch 70 Silicone
More information3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits
3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits With High Ampacity Ground Connection and High-K Stress Relief For Tape Shield, Wire-Over-Tape Shield and Longitudinally Corrugated (LC) Shield
More informationGC-08. Grounding Catalog. Experience. Technology. Answers. P R O D U C T S
GC-08 Grounding Catalog Experience. Technology. Answers. P R O D U C T S TABLE OF CONTENTS HYGROUND IRREVERSIBLE COMPRESSION GROUNDING AND INSTALLATION TOOLING HYGROUND Introduction and Installation...........
More information3M Cold Shrink QT-III Silicone Rubber Indoor Tubular Termination Kit
3M Cold Shrink QT-III Silicone Rubber Indoor Tubular Termination Kit With High-K Stress Relief For Tape Shield, Wire Shield and UniShield Cable 7622-T-110, 7624-T-110, 7625-T-110, 7626-T-110 Instructions
More information3M Cold Shrink QT-III Silicone Rubber Indoor Termination Kits With High-K Stress Relief
3M Cold Shrink QT-III Silicone Rubber Indoor Termination Kits With High-K Stress Relief For Tape Shield, Wire Shield and UniShield Cable 7621-T-95, 7622-T-95, 7624-T-95, 7625-T-95 Instructions IEEE Std.
More information3M Cold Shrink QT-lll Silicone Rubber Skirted Termination Kit 7692-S-4, 7693-S-4, 7694-S-4, 7695-S-4, 7696-S-4
3M Cold Shrink QT-lll Silicone Rubber Skirted Termination Kit 7692-S-4, 7693-S-4, 7694-S-4, 7695-S-4, 7696-S-4 With High-K Stress Relief For Tape Shielded, Wire Shielded and UniShield Cable Instructions
More information3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit
3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit With High-K Stress Relief For Tape Shielded, Wire Shielded and UniShield Cable 7685-S-8 Instructions IEEE Std. No. 48 Class 1 Termination 35
More information3M Cold Shrink QT-II Silicone Rubber Indoor Termination Kits
3M Cold Shrink QT-II Silicone Rubber Indoor Termination Kits With High-K Stress Relief For Tape Shield, Wire Shield and UniShield Instructions IEEE Std. No. 48 Class 1 Termination 8 kv Class, 95 kv BIL:
More information3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit With High-K Stress Relief
3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit With High-K Stress Relief 7642-S-2, 7642-S-2(L) For Jacketed Concentric Neutral (JCN) and Concentric Neutral (CN) Cable Instructions IEEE Std.
More informationCold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief)
Cold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief) Instruction Sheet IEEE Std. No. 48 1990 Class 1 Termination 5/8.7 kv Class 95 kv BIL Kit Contents: 3 Hi K, Tracking Resistant,
More information3M Cold Shrink QT-lll Silicone Rubber Indoor Tubular Termination Kits With High-K Stress Relief
3M Cold Shrink QTlll Silicone Rubber Indoor Tubular Termination Kits With HighK Stress Relief For Tape Shield, Wire Shield and UniShield Cable 7693T150, 7695T150, 7696T150 Instructions IEEE Std. No. 48
More informationMotor Lead Pigtail or V-Stub Splice 5380 Series For 5/8 kv Non-Shielded and Shielded Feeder Cables (Tape, Wire or UniShield Cables)
Motor Lead Pigtail or V-Stub Splice 5380 Series For 5/8 kv Non-Shielded and Shielded Feeder Cables (Tape, Wire or UniShield Cables) Instructions Kit Contents 3 Lug Covers 3 Cold Shrink Terminations 12
More information3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit
3M Cold Shrink QTIII Silicone Rubber Skirted Termination Kit With HighK Stress Relief 3M Cold Shrink QTIII Silicone Rubber Skirted Termination Kit With HighK Stress Relief For Jacketed Concentric Neutral
More informationType Termination Cable Size Copper Aluminum 2 CP2C1-1/0 CP1/0C1-2/0 CP2/0C1-4/0 CP4/0C1 CP4/0A1. Cable 250kcmil CP250C3 CP250A3
C 600V rotectors ECIL UROE Description # for Type Type Termination ize Copper luminum 2 C2C1-1/0 C1/0C1-2/0 C2/0C1-4/0 C4/0C1 C4/01 250kcmil C250C1 C2501 1 to 350kcmil C350C1 C3501 400kcmil C400C1-500kcmil
More informationCTN U-TYPE DIE COLOR INDEX QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473 CTN U-TYPE DIE COLOR INDEX QTY
PAGE 2 PEEP HOLE STANDARD BARREL COPPER LUGS Allows inspection of the termination to assure complete cable insertion GL SERIES One-Hole 32000 GL 80 32002 GL 84 3999 GL 0 32004 GL 4 3200 GL 5 32003 GL 38
More informationInstructions. Quick Term II 2047MT 74. Quick Term II. Silicone Rubber Termination
Instructions Quick Term II Silicone Rubber Termination IEEE Std. No. 48 1990 Class 1 Termination 46 kv Class 250 kv BIL ÁÁ ÁÁ Kit Contents 1 High-K, 8 Skirted Silicone Rubber Termination 1 4 Skirt Silicone
More informationHYDENT TABLE OF CONTENTS
SMALL HYDENT TABLE OF CONTENTS General Information...B-2, B-3 MIL. SPEC. Equivalent Tables...B-4 Types T & YAD...B-5 Types TP & BA...B-6 Types TN & YAES...B-7, B-8 Type YAE-G BOX...B-9 Types YAE-N BOX
More informationSMALL TERMINALS TABLE OF CONTENTS
BURNDY Products Small Terminals SMALL TERMINALS TABLE OF CONTENTS B-1 General Information............ B-2, B-3 MIL. SPEC. Equivalent Tables........ B-4 Types T & YAD.................... B-5 Types TP &
More informationPRODUCTS FOR UNDERGROUND RESIDENTIAL DISTRIBUTION SYSTEMS
PRODUCTS FOR UNDERGROUND RESIDENTIAL DISTRIBUTION SYSTEMS For over 70 years, BURNDY has pioneered and produced economical, dependable connectors and protective devices for urban underground distribution
More informationConnector Installation Guide Compression and Mechanical Connectors
Connector Installation Guide Compression and Mechanical Connectors Typical Cross Section of a Compression Connector Before Installation Before compression, a typical cross section of cable consists of
More informationInsulated Street and Highway Lighting Mechanical Connectors Insulated connectors for above-ground applications.
Lighting Mechanical Connectors Insulated Lighting Mechanical Connectors Insulated connectors for above-ground applications. Rubber Insulation Ensures an insulated connection. Models with Street Light Connectors
More informationweb:
web: CONTENTS INTRODUCTION 00 CU LUGS 00 TERMINALS 00 HEAT SHRINKABLES 00 CABLE TIES 00 CABLE MARKERS 00 GLANDS 00 CLEATS 00 PVC TAPES 00 INTRODUCTION Aftec Electrical Solutions Aftec international with
More informationSmall Terminals BURNDY
B-14 TYPES T AND YAD HYLUG Uninsulated Compression Terminal, Ring Tongue The Type T uninsulated terminals are constructed of pure electrolytic copper. Designed a long brazed seam barrel, standard neck,
More informationCTN QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473. Two-Hole NEMA CTN QTY
PAGE 2 PEEP HOLE STANDARD BARREL COPPER LUGS Allows inspection of the termination to assure complete cable insertion GL SERIES One-Hole 2000 2002 998 999 2004 200 200 2005 200 2008 207 2007 2009 200 20
More informationBURNDY Tooling TABLE OF CONTENTS
TABLE OF CONTENTS HAND-HELD TOOLS Insulated Hand Tools...N-3, N-4 Y10D...N-5 Y10-22...N-6 Y8MRB-1...N-7 MR8 & MR10...N-8 MR15, MR18 & MR20...N-9 MR4C...N-10 Y1MR & Y1MRTC...N-11 M8ND...N-12 MECHANICAL
More informationBonding & Grounding. Telecommunications Main Ground Bars. Telecommunications Main Ground Bar Kits
PhysicalSupport.D 1/21/08 2:10 PM Page 121 GB4X12TMGB GB4X20TMGB GB4X12TMGBKIT Telecommunications Main Ground Bars and Kits Manufactured of 1/4 thick electrolytic tough pitch 110 alloy copper bar. Includes
More informationHI-LINE UTILITY SUPPLY CO. Phone: Fax: WEJTAP TOOLS WEJTAP HOT STICK ACCESSORY KIT
53 WTK Wejtap Kit (includes all of the below items) WTB Power Unit WTF-Y Large Frame - Yellow WTF-RB Small Frame - Red/Blue WTR-Y Large Removal Clip - Yellow WTR-RB Small Removal Clip - Red Blue WTCK Cleaning
More informationIndustrial Electrical Solutions
A. Electrical Spiral Wrap Steel Harness multiple cables into a single manageable bundle Allows breakouts of single/multiple cables Provides abrasion protection for wire, cables, hoses, and tubing Reverse
More informationTABLE OF CONTENTS PATCUT245CUAL-18V... N-52 BCC1000CUAL... N-53
BURNDY Products MECHANICAL AND RATCHET Y10D..................................... N-3 Y10-22.................................... N-4 MCC20, MCC500 & MCC1000................ N-5 RCC556, RCC600, RCC750HD,
More informationSUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L
SUBMERSIBLE SECONDARY CONNECTORS -1- Index TYPE SSBC350-L (Wide-Port Spacing) Rubber Insulated Secondary Connectors SURE-SEAL RUS Approved User friendly wide-port spacing (50% more room for cable training).
More informationDISTRIBUTION CONNECTORS SECTION DF COMPRESSION TERMINALS. Aluminum Compression Lugs Aluminum Bi-Metal Pin Terminals Copper Compression Lugs
DISTRIBUTION CONNECTORS COMPRESSION TERMINALS Aluminum Compression Lugs Aluminum Bi-Metal Pin Terminals Copper Compression Lugs SECTION VERSAtile ALUMINUM COMPRESSION TERMINAL TYPE VCEL For use with either
More informationShelf 19 version) (Expansion Shelf 19 version) (Main Shelf 23 version) (Expansion Shelf 23 version)
SYSTEM OVERVIEW Description: +24VDC to -48VDC @ up to 375A converter system. The NetSure DCS48375 Converter System is comprised of a main shelf and up to two (2) expansion shelves. Each shelf provides
More informationHeavy Duty Copper Battery Terminals
Heavy Duty Copper Battery Terminals Constructed of 131 contact copper to provide high conductivity. Raised characters to ensure legibility of important information regarding cable size, post type, and
More informationELB ES. Product Installation Instructions
ELB-25-210-ES 200A 25kV Class Loadbreak Elbow with Integral Jacket Seal for Copper Tape (CT) and Jacketed Concentric Neutral (JCN) cables Product Installation Instructions Safety Instructions When installing
More informationGrounding Busbars. Harger provides quality UL Listed grounding busbars to the electrical and telecommunication markets.
LINE CARD Grounding Exothermic Lightning Protection Grounding Busbars Harger provides quality UL Listed grounding busbars to the electrical and telecommunication markets. 2 Grounding Busbars & Kits s GBI14210G
More informationAluminum and Steel Liquidtight Strain Relief Cord and Cable Connectors
Application Provide a liquidtight and strain relief termination for flexible type neoprene, hypalon, and PVC jacketed power or control cord and cable. For use in wet or dry locations sealing electrical
More information2.5mm pitch/disconnectable Crimp style connectors. 1Certified LR R PC board layout (viewed from component side) and Assembly layout
Emboss Tape 2.5mm pitch/disconnectable Crimp style connectors Radial Tape Locking device Solder crack preventive material Low insertion force Insertion guide mechanism Applicable to automatic board mounting
More informationInsulated Crimp Terminals
CONTENTS PVC Insulated ring terminals 3 PVC insulated spade terminals 3 PVC insulated pin terminals 4 PVC insulated blade terminals 4 PVC insulated butt connectors 4 PVC insulated female disconnectors
More informationOur overhead products go above and beyond all others. QUICK REFERENCE. Overhead Connectors. & Covers. Overview
Overview QUICK REFERENCE Overhead Connectors & Covers page(s) Our overhead products go above and beyond all others. We have plenty of overhead connectors. From transformer eyebolts and stirrup connectors
More informationUK 6-FSI/C. Extract from the online catalog. Order No.:
Extract from the online catalog UK 6-FSI/C Order No.: 3118203 Flat-type fuse terminal block, cross section: 0.2-6 mm², AWG: 26-8, width: 8.2 mm, color: black Commercial data EAN 4017918100605 Pack 50 pcs.
More informationSUBMERSIBLE SECONDARY CONNECTORS
SUBMERSIBE SECONDARY CONNECTORS TYPE SSBC350- (Wide-Port Spacing) Rubber Insulated Secondary Connectors SURE-SEA RUS Approved User friendly wide-port spacing (50% more room for cable training). Multiple
More information...at Altech, of course!
FANTASTIC approved FERRULES...at Altech, of course! Approved for the US & Canadian Market Other great Altech CSA approved products: Miniature Circuit Breakers / Manual Motor Controllers DIN Rail and Panel
More informationHVAC No. MFG Part No. Description Price
Thermostat Wire Ground Wire 392327 423011 118533 144760 118534 118535 14/4-50 18/2-RF/UL 18/2-UL 18/3-SPC 18/3-UL 18/4-UL 14/4 Tray Cable, 600V, THHN, Stranded, 50' Roll 18/2, Signaling Cable, Shielded,
More informationSafety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures
Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures 30-600 Amperes: TG and TH 800-1200 Amperes: TC Equipment Ground Kits Ampere Rating AWG/kcmil Copper AWG/kcmil Aluminum Standard Package
More informationBURNDY. Tooling TABLE OF CONTENTS. DIES 12 Ton U Dies... N-4 W Dies... N-4 UDIEKITCU, UDIEKITAL, UDIEKITHYGRD U Die Kits... N-5 CRIMPERS CUTTERS
BURNDY TABLE OF CONTENTS DIES 12 Ton U Dies........................ N-4 W Dies.............................. N-4 UDIEKITCU, UDIEKITAL, UDIEKITHYGRD U Die Kits........... N-5 CRIMPERS MECHANICAL AND RATCHET
More information3SE03 North American Limit Switches
General Information Features Modular plug-in Prewired receptacle with pin connector Prewired cable Features UL Listed, CSA Certified. UL File: E47512 All Metal Captive Screws. Keyed, Four-Directional Head.
More informationINSTALL INSTRUCTIONS DC C-EV. Installation Instructions: DC C-EV.
INSTALL INSTRUCTIONS DC6-48-60-0-8C-EV Installation Instructions: DC6-48-60-0-8C-EV INSTALL INSTRUCTIONS DC6-48-60-0-8C-EV Contents Section Description Page 1 Copyright 2 1.1 Disclaimer 2 1.2 Warnings
More informationHan K 3/0, K 3/2 / Han HC Modular. Contents Technical characteristics Han K 3/0, Han K 3/ Inserts Han K 3/0, Han K 3/
Han K 3/0, K 3/2 / Han HC Contents Page Technical characteristics Han K 3/0, Han K 3/2... 14.02 Inserts Han K 3/0, Han K 3/2... 14.03 Hoods/Housings Han 24 HPR for Han K 3/0, Han K 3/2... 14.04 Technical
More informationDual-Feed 600A Load Center Frame Power :: 600CB10 and 600CB12 User Manual
Power :: 600CB10 and 600CB12 User Manual 600CB10 - Front View 600CB10-C - Rear View Applies to : 600CB10 :: 600CB10-C :: 600CB10-VL :: 600CB10-CL :: 600CB12 :: 600CB12-C :: 600CB12-VL :: 600CB12-CL Table
More informationEasy assembly with standard tools. Fully insulated for direct mounting to steel panels
Cam-Lok J Series Connectors or NEMA 4 Cam-Lok J Series Connectors are specifically designed to meet the needs of demanding portable applications. J Series and Receptacles are the proven industry standard
More informationLithium-Ion Battery-Powered Tools
Lithium-Ion Battery-Powered Tools Thomas & Betts. Your best connection for innovative solutions. Wire & Cable Management Cable Protection Systems Power Connection & Control S a f e t y Te c h n o l o g
More informationEcoSystem Cable Low-Voltage Cables. Features Internal conductors match EcoSystem device terminal and lead color scheme.
EcoSystem Cable 369385c 1 01.22.2018 Custom designed cable, for use with EcoSystem components, improves system performance and decreases installation time. Cable is available for sensor connections and
More informationSta-Kon s Long Barrel Design
Terminals Why Sta-Kon Terminals Are Better Like any other value added manufacturing process, using the best material is only a start. Our Sta- Kon terminals are all manufactured with the customer in mind,
More informationCam-Lok. Single pole connectivity. The industry standard for reliable service under the most severe operating conditions.
Plugs & receptacles Cam-Lok single pole connectivity Cam-Lok Single pole connectivity The industry standard for reliable service under the most severe operating conditions. Cam-Lok single pole connectivity
More informationSafety switches for hinges
Safety switches for hinges Selection diagram ACTUATORS L L6 L9 L16 FR FM FX FZ FK CONTACT BLOCKS 6 7 9 14 18 snap action 1NO+1N, make before break, shifted, close 21 4 66 NC 2NO+ 1NO+ CONDUIT ENTRIES Threaded
More informationATT DC POWER AND GROUNDING MINOR MATERIAL LIST A/
GROUNDING CABLE/MATERIAL Contact: John Messina (203) 553-0232 CABLE/WIRE: Class B - Standard Strand (Type 3 Braid) CABLE/WIRE 14 AWG-Stranded RHH 90C Rated Dry/Damp & 60C Wet, Braid CABLE/WIRE 12 AWG-Stranded
More informationGrounding equipment COOPER POWER SERIES. Temporary Connections CA325004EN. Contents
Temporary Connections CA325004EN Supersedes November 2016 Grounding equipment COOPER POWER SERIES Contents Description Page Grounding elbow products... 2 Grounding elbow and kit product ratings... 5 200
More informationPIT 2,5-TG. Extract from the online catalog. Order No.:
Extract from the online catalog PIT 2,5-TG Order No.: 3210185 Disconnect terminal block, Connection type: Leg spring connection, Cross section: - 4 mm², AWG: 26-12, Nominal current: 20 A, Nominal voltage:
More informationEcoSystem Bus Cable. EcoSystemTM. Cable. Low Voltage Cables
EcoSystemTM EcoSystem -1 2.19.08 Custom designed cable for EcoSystem improves system performance and decreases installation time. is available for sensor connections and EcoSystem bus connections. Both
More informationHK-003,HC SERIES HK-003 HCSERIES. Modular Heavy-current connector WAIN 12-01
HK-00, SERIES HK-00 SERIES Modular Heavy-current connector 12-01 HK-00/0HK-00/2 Heavy-current inserts HE-006 HK-00 Technical characteristics Specifications Approvals Inserts Number of contacts Electrical
More informationThank you for your interest in the Copper Battery Terminals through the farm magazine.
Thank you for your interest in the Copper Battery Terminals through the farm magazine. We have enclosed our literature on the battery terminals and related products along with our product listing and catalog
More informationOLS U T I L I T Y S E G M E N T
BURNDY TOOLS UTILITY SEGMENT BURNDY Tools exemplify both reliability and engineering knowledge unsurpassed in the industry. BURNDY.COM 3 BURNDY TOOL SERVICE GETS IT DONE! GET IT FIXED Tools repaired at
More informationTermco Lugs and Terminals
Termco Lugs and Terminals Copper Crimp Lugs and Links Pre- and Uninsulated Terminals and Connectors www.hesales.com.au Termco Lugs and Terminals Copper Lugs & HD Terminals All Termco Heavy Duty Copper
More informationConnector System Guide Compression Connectors Grounding Connectors Tools for Industrial Electrical Applications
Connector System Guide Compression Connectors Grounding Connectors Tools for Industrial Electrical Applications Step One Preparing the Cable Strip the insulation carefully to avoid nicking or cutting conductors
More informationGROUNDING & BONDING PRODUCTS
GROUNDING & BONDING PRODUCTS Busbars Page 5-3 Insulators Page 5-8 Grounding Products Page 5-9 Compression Tools, Lugs & Taps Page 5-14 Learn About CPI s Extended Limited Warranties for coverage of (2)
More informationDART. Operation / Installation Manual. Digital Analog Remote Transducer. Computer Weld Technology, Inc. Manual Part Number: A8M5015 Revised: 9/28/2004
Computer Weld Technology, Inc. 10702 Old Bammel N Houston Rd. Houston, TX 77086 Phone: (713) 462-2118 Fax: (713) 462-2503 Email: cwt@cweldtech.com DART Digital Analog Remote Transducer Operation / Installation
More informationCam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions.
Cam-Lok Single Pole Connectivity The industry standard for reliable service under the most severe operating conditions. Cam-Lok Single Pole Connectivity Cam-Lok connectors are the industry standard Cam-Lok
More informationwiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS
wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 580F 036-150 3 to 12 1 / 2 Tons Cancels: New WD 580F.36.1 10/15/00 *Low NOx/California compliant units. DIAGRAM INDEX UNIT LABEL
More informationHYDRAULIC CRIMPING TOOL HT51
1 HYDRAULIC CRIMPING TOOL HT51 general features This two speed lightweight and compact, hydraulic tool is ideal for working in confined spaces. Having the benefit of spring loaded handles, the dies can
More informationWestinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana Indoor-Outdoor Altitude 0-10,000 feet KV
May 975 Supersedes 8-2 F WE A, Pages -2, dated January 975 E, D, C/98 /DB Dimensions, Weights and Creep These notes apply to all ratings.. These arresters are designed for 0,000 feet. ncrease clearances
More informationRMP SERIES INFORMATION GUIDE
RMP SERIES INFORMATION GUIDE DESCRIPTION & DESIGN FEATURES Applications RMP series connectors can be used wherever high amperage connection of AC or DC power is required. Typical applications are the connection
More informationTHHN10STBRCP1250 THHN 10 STR Brown 1250 CP
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN10STBRCP1250 THHN 10 STR Brown 1250 CP Southwire Company Catalog Number THHN10STBRCP1250 Manufacturer Southwire Company
More informationDuraSeal Heat-Shrinkable Environmentally Sealed, Nylon Insulated Crimp Terminals and Disconnects
Sealed, Nylon Insulated Crimp Terminals and Disconnects Product Facts Resistance to moisture and abrasion Strain relief Protection from wire pull-out Easy installation UL and CUL listed R Approvals and
More informationTerminal/Alternator Auxiliary Terminal to Light to Regulator Fuse or Switch to Pumps
Can I use regular wire for my boat? The answer to this common question is a qualified yes, if the wire is SAE (Society of Automotive Engineering) J378, J1127 or J1128. These wires are designed for surface
More informationEPIC CIRCON M23 Series
CIRCON M23 Series Application Advantage Rugged nickel-plated, die-cast zinc body Positive vibration protection for use with motor drives and moving assemblies Integral EMC cable gland provides strain relief,
More informationPT 2,5-QUATTRO/2P BU. Extract from the online catalog. Order No.:
Extract from the online catalog PT 2,5-QUATTRO/2P BU Order No.: 3209675 Feed-through modular terminal block, Connection method: Pushin / plug connection, Cross section: - 4 mm², AWG 26-12, Width: 5.2 mm,
More informationPT 2,5-TWIN/1P BU. Extract from the online catalog. Order No.:
Extract from the online catalog PT 2,5-TWIN/1P BU Order No.: 3209646 Feed-through modular terminal block, Connection method: Pushin / plug connection, Cross section: - 4 mm², AWG 26-12, Width: 5.2 mm,
More informationSRK6X and SRK6XFG Battery-powered Crimping Tool
OPERATION MANUAL Serial Number SRK6X and SRK6XFG Battery-powered Crimping Tool Read and understand all of the instructions and safety information in this manual before operating or servicing this tool.
More informationPSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.
Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables. Sizes are available for all shielded cables in voltage classes from 15kV through 46kV.
More informationDemarcation Fuse/Circuit Breaker Alarm Panel 125DM08. Installation Guide
Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08 Installation Guide Table of Contents 1.1 Overview... 2 1.2 Specifications... 3 1.3 Inspection... 3 1.4 Installation... 4 1.4.1 Important Installation
More information10. ACCEPTED EQUIPMENT
10. ACCEPTED EQUIPMENT 10.1 GENERAL In order to meet the minimum specifications of these Electric Service Requirements, certain equipment shall have the acceptance of the Company. Manufacturers of equipment
More informationCold Shrink Silicone Rubber Termination QT-III 7672-S-8-JCN
3 Cold Shrink Silicone Rubber Termination QT-III 7672-S-8-JCN Instructions IEEE Std. No. 48-1996 Class 1 Termination 69 kv Class 350 kv BIL IEC 60840 72,5 kv Kit Contents: 1 Silicone Rubber Lug Seal Insulator
More informationHCI General Purpose Disconnects
30 AMPERES 1oo AMPERES C General Purpose Disconnects AMPERES 0 AMPERES Quality Designed... Thoroughly Tested orsepower Rated 30-0 Amperes, 240, 480 and 0 Volts AC, 2 Volts DC with adjustable operating
More informationCompression Connectors
Compression s Compression H- s Type WR Wide Range luminum s O and D Die Seven Program Pass the requirements of NSI C9. Seven Program provides superior connector performance, lower connection Field-proven
More informationBoxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.
Circuit Breaker / Column Type Type C1 240 Volts AC Mains Branch UL Short Circuit Rating 200,000 IR Branch Breaker Symmetrical Interrupting Rating Based on Underwriters Test Procedure Type C2 480Y/277 Volts
More informationFeatures. Track Length System Length Storage Length. Active Travel. System Depth Loop Depth Tow Trolley. Intermediate Trolley
Magnetek s Electromotive Systems Mill Duty I-Beam Festoon Systems efficiently and economically deliver power and control to cranes used in a variety of severe industrial environments. Features Capacity
More informationSmart Switch Basic Kit - 24 volt ( ) Wiring Instructions
Smart Switch Basic Kit - 4 volt (54-08) Wiring Instructions NB 8/0/ 6 ga. wire 6 ga. wire 6 ga. wire OUT IN 6 ga. wire Yellow Black Blue 50 AMP BREAKER MOTOR 6 ga. wire 6 ga. wire 6 ga. wire ROCKER SWITCH
More informationCam-Lok Single Pole Connectors
Cam-Lok Single Pole Connectors Cooper Interconnect Cam-Lok Single Pole Connectors are specially designed to provide the ultimate in reliable service, even under the most severe operating conditions. These
More informationApplication Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D
Application Specification Circular Plastic Connector (CPC) 114-13137 Series 45 System 05 AUG 14 Rev D NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions
More informationOur Power Team High-Current, Rail-Mount Terminal Blocks for Conductors up to 185 mm 2 (350 kcmil)
Our Power Team High-Current, Rail-Mount Terminal Blocks for Conductors up to 185 mm 2 (50 kcmil) vibration-proof fast maintenance-free WAGO BENEFITS Using springs instead of screws is the key to WAGO s
More informationAirStar Tandem Installation Kit Part Number 85694
Tandem Installation Kit Part Number 8569 Kit Parts Supplied Part No. Description Quantity 60510 10 PSI Safety Relief Valve 866 85-115 psi 1 85686 Installation Schematic for two Tandem compressors 1 System
More information3SE03 North American Limit Switches
General Information Features Modular plug-in Prewired receptacle with pin connector Prewired cable Features UL Listed, CSA Certified. UL File: E47512 All Metal Captive Screws. Keyed, Four-Directional Head.
More informationCABLE GRIPS Strain-Relief Grips Pulling Grips Support Grips
Tough and dependable, Woodhead cable grips and cord grip bodies are reliable workhorses in any plant environment. They serve as flexible holding devices used to pull cable, rope, or tubing into place,
More informationFused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series
28 Fused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series 281... Blown fuse indication Exchange of fuse Blown fuse indication by LED or neon lamp Before exchanging the
More informationMain catalogue. ESSAILEC Test Blocks
Main catalogue ESSAILEC Test Blocks Test Blocks ESSAILEC has been especially designed to fit the electricity Utilities requirements for safe and reliable testing. ESSAILEC allows the testing, without any
More information