wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS

Size: px
Start display at page:

Download "wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS"

Transcription

1 wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 580F to 12 1 / 2 Tons Cancels: New WD 580F /15/00 *Low NOx/California compliant units. DIAGRAM INDEX UNIT LABEL DIAGRAM Unit 580F Voltage-Phase-Hertz Type Label Diagram Figure No. 208/ Schematic/Component Arrangement 50DK / Schematic/Component Arrangement 50DK , Schematic/Component Arrangement 50DK Schematic/Component Arrangement 50DK / * Schematic/Component Arrangement 50DK * Schematic/Component Arrangement 50DK / Schematic/Component Arrangement 50DK / Schematic/Component Arrangement 50DK Schematic/Component Arrangement 50DK Schematic/Component Arrangement 50DK / * Schematic/Component Arrangement 50DK * Schematic/Component Arrangement 50DK / Schematic/Component Arrangement 50DK Schematic/Component Arrangement 50DK Schematic/Component Arrangement 50DK / Schematic/Component Arrangement 50DK Schematic/Component Arrangement 50DK Schematic/Component Arrangement 50DK ACCESSORY WIRING Description Unit Size Fig. No. Motormaster I Control Motormaster II Control Time Guard II Device Solid-State Enthalpy Control Differential Enthalpy Control EconoMi$er EconoMi$er Sensor Wiring Power Exhaust

2 LEGEND AHA Adjustable Heat Anticipator C Contactor, Compressor CAP. Capacitor CB Circuit Breaker CC Cooling Compensator COMP Compressor Motor D Diode EC Enthalpy Control ECON Economizer EPS Emergency Power Supply (Nine-Volt Battery) EQUIP Equipment ER Economizer Relay FPT Freeze-Up Protection Thermostat GND Ground HPS High-Pressure Switch HS Hall Effect Sensor I Ignitor IDM Induced-Draft Motor IFC Indoor-Fan Contactor IFM Indoor-Fan Motor IFMOVL Indoor-Fan Motor Overload IGC Integrated Gas Unit Controller LED Light-Emitting Diode LPS Low-Pressure Switch LS Limit Switch MGV Main Gas Valve MTR Motor OAT Outdoor-Air Thermostat OFC Outdoor-Fan Contactor OFM Outdoor-Fan Motor OLR Overload Relay P Plug PL Plug Assembly QT Quadruple Terminal R Relay RS Rollout Switch SAT Supply-Air Thermostat SEN Sensor ST Start Thermistor SW1 Switch Fully Open SW2 Switch Fully Closed SW3 Switch Minimum Vent Position SW4 Switch Maximum Vent Position TC Thermostat, Cooling TDR Time-Delay Relay TH Thermostat, Heating TRAN Transformer Field Splice Marked Wire Terminal (Marked) Terminal (Unmarked) Terminal Block Splice Splice (Marked) Factory Wiring Field Control Wiring Field Power Wiring Accessory or Optional Wiring To indicate common potential only. Not to represent wiring. Ground ( Capacitor 1. If any of the original wire furnished must be replaced, it must be replaced with Type 90 C wire or its equivalent. 2. Thermostat: HH07AT170, 172, 174, and P Subbase: HH93AZ176, 178, and P , 1883 NOTES FOR FIG. 1, 7 3. Set heat anticipator at.14 amp for units with 2 stages of heating. Set stage two anticipator at.14 amps. 4. Use copper conductors only. 5. TRAN is wired for 230-v unit. If unit is to be run with 208-v power supply, disconnect BLK wire from 230-v tap and connect to 208-v tap. 1. If any of the original wire furnished must be replaced, it must be replaced with Type 90 C wire or its equivalent. 2. Three-phase motors are protected under primary single-phasing conditions. 3. Thermostat: HH07AT170, 172, 174, and P Subbase: HH93AZ176, 178, and P , 1883 NOTES FOR FIG. 2, 5, 8, 11, 13, Set heat anticipator at.14 amp for units with 2 stages of heating. Set stage two anticipator at.14 amps. 5. Use copper conductors only. 6. TRAN is wired for 230-v unit. If unit is to be run with 208-v power supply, disconnect BLK wire from 230-v tap (ORN) and connect to 208-v (RED). Insulate end of 230-v tap. 1. If any of the original wire furnished must be replaced, it must be replaced with Type 90 C wire or its equivalent. 2. Three-phase motors are protected under primary single-phasing conditions. 3. Thermostat: HH07AT170, 172, 174, and P Subbase: HH93AZ176, 178, and P , 1883 NOTES FOR FIG. 3, 4, 6, 9, 10, 12, 14, 15, 17, Set heat anticipator at.14 amp for units with 2 stages of heating. Set stage two anticipator at.14 amps. 5. Use copper conductors only. 2

3 Fig. 1 Schematic/Component Arrangement; 580F036,048, 208/

4 Fig. 2 Schematic/Component Arrangement; 580F036,048, 208/

5 Fig. 3 Schematic/Component Arrangement; 580F036,048,

6 Fig. 4 Schematic/Component Arrangement; 580F036,048,

7 Fig. 5 Schematic/Component Arrangement; Low NOx 580F036060N, N; 580F048060N, N, N; California Compliant 580F036114, 580F048149; 208/

8 Fig. 6 Schematic/Component Arrangement; Low NOx 580F036060N, N; 580F048060N, N, N; California Compliant 580F036114, 580F048149;

9 Fig. 7 Schematic/Component Arrangement; 580F060, 208/

10 Fig. 8 Schematic/Component Arrangement; 580F060, 208/

11 Fig. 9 Schematic/Component Arrangement; 580F060,

12 Fig. 10 Schematic/Component Arrangement; 580F060,

13 Fig. 11 Schematic/Component Arrangement; Low NOx 580F060060N, N, N; California Compliant 580F060149; 208/

14 Fig. 12 Schematic/Component Arrangement; Low NOx 580F060060N, N, N; California Compliant 580F060149;

15 Fig. 13 Schematic/Component Arrangement; 580F072, 208/

16 Fig. 14 Schematic/Component Arrangement; 580F072,

17 Fig. 15 Schematic/Component Arrangement; 581B072,

18 18 Fig. 16 Schematic/Component Arrangement; 580F , 208/

19 19 Fig. 17 Schematic/Component Arrangement; 580F ,

20 20 Fig. 18 Schematic/Component Arrangement; 580F ,

21 580F LEGEND C Contactor 580F Fig. 19 Motormaster I Wiring Details LEGEND C Contactor OFC Outdoor-Fan Contactor TRAN Transformer *The Motormaster II head pressure controller is equipped with an alternate operating mode. When this mode is selected, the controller shifts the fan cycle sequence to effectively raise the average condensing temperature approximately 20 F higher than the standard operating mode. In this alternate mode, the outdoor fan begins cycling at higher outdoor ambient temperatures. This mode should only be used if the evaporator coil shows signs of frosting at low outdoor ambient temperatures. To select the alternate operating mode, move the jumper wire on the Motormaster II control board from reset T1 to reset T2. NOTE: Motormaster II transformer is wired for 460-v supply; it must be rewired for 208/230-v application. Be sure to insulate unused tap. Refer to color code. Fig. 20 Motormaster II Wiring Schematic, 580F

22 LEGEND C Contactor OFC Outdoor-Fan Contactor TRAN Transformer *The Motormaster II head pressure controller is equipped with an alternate operating mode. When this mode is selected, the controller shifts the fan cycle sequence to effectively raise the average condensing temperature approximately 20 F higher than the standard operating mode. In this alternate mode, the outdoor fan begins cycling at higher outdoor ambient temperatures. This mode should only be used if the evaporator coil shows signs of frosting at low outdoor ambient temperatures. To select the alternate operating mode, move the jumper wire on the Motormaster II control board from reset T1 to reset T2. NOTE: Motormaster II transformer is wired for 460-v supply; it must be rewired for 208/230-v application. Be sure to insulate unused tap. Refer to color code. Fig. 21 Motormaster II Wiring Schematic, 580F TIME GUARD I I DEVICE BRN BRN T1 T3 T ECONOMIZER OR Y1 OR Y2* CLO COMPRESSOR SAFETIES HIGH EFFICIENCY 3 TO 12 1 / 2 TON ROOFTOP UNITS C OR CR TIME GUARD I I DEVICE BRN BRN T1 T3 T C CLO CR LEGEND *Per compressor circuit. ECONOMIZER OR Y1 OR Y2* Contactor Compressor Lockout Control Relay CLO COMPRESSOR SAFETIES STANDARD EFFICIENCY 3 TO 12 1 / 2 TON ROOFTOP UNITS Fig. 22 Time Guard II Device, 580F C OR CR 22

23 A B C D LED TR TR1 SO + SR VAC SUPPLY FROM ECONOMIZER CONTROL } SECTION (RED TO TR, BRN TO TR1) } TO SENSOR MOUNTED ON BACK OF CONTROL 620 ohm JUMPER GRAY WIRE FROM ECONOMIZER HARNESS RED WIRE FROM ECONOMIZER SWITCH 3 (NORMALLY CLOSED) A B C D LED TR SO SR 2 TR VAC SUPPLY FROM ECONOMIZER CONTROL SECTION (RED TO TR, BRN TO TR1) TO SENSOR MOUNTED ON BACK OF CONTROL S (HH57AC078 + SENSOR) GRAY WIRE FROM ECONOMIZER HARNESS RED WIRE FROM ECONOMIZER SWITCH 3 (NORMALLY CLOSED) NOTE: Switches shown in high enthalpy state. Terminals 2 and 3 close on enthalpy decrease. Fig. 23 Wiring Connections for Solid-State Enthalpy Control (HH57AC077) NOTES: 1. Remove factory-installed jumper across SR and + before connecting wires from HH57AC078 sensor. 2. Switches shown in high outdoor-air enthalpy state. Terminals 2 and 3 close on low outdoor air enthalpy relative to indoor air enthalpy. Fig. 24 Wiring Connections for Differential Enthalpy Control (HH57AC077 and HH57AC078) LEGEND OAT Outdoor-Air Thermostat Fig. 25 EconoMi$er Wiring 23

24 ECONOMI$ER CONTROLLER OAT COM OAH -15 V RAT COM RAH +15 V CO 2 (+) CO 2 COM DAT COM REM POT COM LED COM BROWN VIOLET WHITE RED BROWN VIOLET WHITE RED TEMP TEMP COM OUT PWR TEMP TEMP COM OUT PWR CO 2 SENSOR V+ 24 COM VAC SUPPLY AIR TEMPERATURE SENSOR PINK TEMP VIOLET TEMP OUTDOOR AIR SENSOR RETURN AIR SENSOR Fig. 26 EconoMi$er Sensor Wiring, 580F TO FUSED DISCONNECT RED GRAY RED YEL BLU GRAY HT01AH859 (575 VAC) H1 X4 X2 X3 H2 X1 HT01AH850 (460 VAC) H1 X4 H3 X2 H2 X3 H4 X1 SECONDARY 230VAC SECONDARY 230VAC FIELD SUPPLIED WIRING BLACK OR COMPRESSOR 1 CONTACTOR VAC BLACK LT. BLUE B 2 x 4 IN. HANDY BOX BLACK L1 BLUE L2 GREEN GND VAC 1 PHASE 23 4-PIN CONNECTOR PLUG L1 L2 GND BLACK BLUE GREEN BROWN FAN 1 C1 GREEN/ YELLOW BLACK BLUE BLACK LT. BLUE A 6 9 B R1 24 VAC 3-PIN CONNECTOR PLUG ORANGE YELLOW BROWN BROWN FAN 2 C1 GREEN/ YELLOW BLACK A R2 24 VAC BLUE Fig. 27 Wiring Diagram for Power Exhaust System Copyright 2000 Bryant Heating & Cooling Systems CATALOG NO

Wiring Diagrams (Including Accessories) (50/60 Hz)

Wiring Diagrams (Including Accessories) (50/60 Hz) UNIT 38AKS 028-044 ELECTRICAL CHARACTERISTICS (V-Ph-Hz) 208/230-3-60 460-3-60 575-3-60 230-3-50 346-3-50 380-3-60 400-3-50 Typical Field Wiring Electronic Programmable Thermostat, Liquid Line Solenoid

More information

Wiring Diagrams DIAGRAM INDEX

Wiring Diagrams DIAGRAM INDEX 30HK040-060;30HL050,060;30HW018-040 Reciprocating Liquid Chillers with ComfortLink Controls 50/60 Hz Wiring Diagrams DIAGRAM INDEX UNIT 30 VOLTAGE DIAGRAM TYPE FIGURE LABEL DIAGRAM All Component Arrangement

More information

EconoMi$er, Power Exhaust, and Sensor Installation Instructions

EconoMi$er, Power Exhaust, and Sensor Installation Instructions Small Rooftop Units Gas Heating/Electric Cooling, Electric Cooling, and Heat Pump Units 3 to.5 Tons (50/60 Hz) EconoMi$er Package for Vertical and Horizontal Duct Systems Issue Date /0/0 EconoMi$er, Power

More information

Installation Instructions

Installation Instructions 00A0, 0A0-0A0 080A00 08A00 For Use With Vertical EconoMi$ert IV or EconoMi$ert Only SMALL ROOFTOP UNITS ACCESSORY VERTICAL EXHAUST GAS HEATING/ELECTRIC COOLING, ELECTRIC COOLING, AND HEAT PUMP UNITS TO5TON

More information

Installation Instructions

Installation Instructions 08A0, 09A0, 08A00, 08A00 For Use With Horizontal EconoMi$ert IV or EconoMi$ert Only SMALL ROOFTOP UNITS ACCESSORY HORIZONTAL EXHAUST GAS HEATING/ELECTRIC COOLING, ELECTRIC COOLING, AND HEAT PUMP UNITS

More information

WIRING DIAGRAMS FB4C FE4A/FE5A FH4C FV4C FX4D FY5B PF4MA PF4MB LABEL

WIRING DIAGRAMS FB4C FE4A/FE5A FH4C FV4C FX4D FY5B PF4MA PF4MB LABEL FAN COILS ACCESSORY ELECTRIC HEATERS WIRING DIAGRAMS FIG. FIELD-INSTALLED HEATER MODEL FB4C FE4A/FE5A FH4C FV4C FX4D FY5B PF4MA PF4MB LABEL 1 KFCEH0401N03A 18,24 x 001 x 19,25 18,24 18,19,24,25 x 340816-101

More information

Installation Instructions

Installation Instructions CRPWREXH08A0, CRPWREXH09A0, CRPWREXH08A00, CRPWREXH08A00 For Use With Horizontal EconoMi$er IV, EconoMi$er, or EconoMi$er X (W70) Installation Instructions TABLE OF CONTENTS PACKAGE CONTENTS... PACKAGE

More information

Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Figure Number. Label Diagram No. 30HX ALL ALL

Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Figure Number. Label Diagram No. 30HX ALL ALL Wiring Diagrams 30HXA, 30HXC Condenserless and Fluid-Cooled Chillers 50/60 Hz DIAGRAM INDEX POWER SCHEMATICS Unit 30HXA,C Voltage Figure Number Label Diagram No. 30HX 076-186 ALL 1 500141 206-271 ALL 2

More information

PGC COMMERCIAL PACKAGED GAS/ELECTRIC

PGC COMMERCIAL PACKAGED GAS/ELECTRIC PGC COMMERCIAL PACKAGED GAS/ELECTRIC PRODUCT SPECIFICATIONS 7½ TO 10 TON 10.3 EER COOLING CAPACITY 86,000-116,000 BTU/H HEATING CAPACITY 193,000-225,000 BTU/H The Goodman PGC Commercial Packaged Gas/Electric

More information

Installation Instructions

Installation Instructions 018A00 CALOWAMB023A00 CALOWAMB037A00 - CALOWAMB042A00 SPLIT SYSTEM AC UNITS ACCESSORY MOTORMASTER R I HEAD PRESSURE CONTROLLER 15 & 20 TONS Installation Instructions IMPORTANT: Read these instructions

More information

Installation Instructions

Installation Instructions CALOWAMB001A00 - CALOWAMB011A00 CALOWAMB030A00 - CALOWAMB036A00 SPLIT SYSTEMS ACCESSORY MOTORMASTER R I HEAD PRESSURE CONTROLLER 6to12.5TONS Installation Instructions IMPORTANT: Read these instructions

More information

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1 filter ILL. 3. Screw ICP INSTALLATION INSTRUCTIONS for (NPECOMZR006A00) ICP's economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions completely and carefully

More information

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

Blank-off. HVAC unit screws. Spacer for 1 filter ILL. 3. Screw ICP INSTALLATION INSTRUCTIONS for NPECOMZR00A00 ICP's economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions completely and carefully

More information

Installation Instructions

Installation Instructions 05A00 053A00 VERTICAL AND HORIZONTAL ECONOMIZER IV ACCESSORY MEDIUM ROOFTOP UNITS 5 to 5 TONS TABLE OF CONTENTS PACKAGE USAGE... SAFETY CONSIDERATIONS... PACKAGE CONTENTS... GENERAL... ACCESSORIES LIST...

More information

Installation Instructions

Installation Instructions PLOWAMB001A00 SMALL ROOFTOP UNITS GAS HEAT/ELETRI OOLING, ELETRI OOLING AND HEAT PUMP UNITS AESSORY MOTORMASTERR II HEAD PRESSURE ONTROLLER 60Hz 3to12---1/2tons Installation Instructions IMPORTANT: Read

More information

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1 filter ILL. 3. Screw MicroMetl INSTALLATION INSTRUCTIONS for 0637-0311 (CPECOMZR006A00) MicroMetl's 0637 economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions

More information

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT Service Literature Corp. 9711 L7 CB29M CB30M ELITE 10 CB29M and ELITE 12 CB30M SERIES UNITS INCLUDING ECB29 The Elite 10 CB29M and Elite 12 CB30M are high efficiency blower coils. Several models are available

More information

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls UNIT OBJECTIVES After studying this unit, the reader should be able to Describe and identify power- and non-power-consuming Describe

More information

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS CRECOMZR05B00 CRECOMZR055B00 VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS TABLE OF CONTENTS PACKAGE USAGE...1 SAFETY CONSIDERATIONS...1 PACKAGE CONTENTS...1 GENERAL...2

More information

Product Data. 38AUZ/D 50 Hz Commercial Split Systems Air Conditioning Condensing Units 18.3 kw to 59.2 kw FEATURES/BENEFITS

Product Data. 38AUZ/D 50 Hz Commercial Split Systems Air Conditioning Condensing Units 18.3 kw to 59.2 kw FEATURES/BENEFITS Z/D 50 Hz Commercial Split Systems Air Conditioning Condensing Units 18.3 kw to 59.2 kw Product Data FURES/BENEFITS These dependable outdoor air cooled condensing units match Carrier s indoor-air handlers

More information

CAS. Product Specifications

CAS. Product Specifications CAS Product Specifications COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 to 241 models Two stage

More information

CAS. Product Specifications

CAS. Product Specifications CAS Product Specifications COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 to 150 models Terminal

More information

Package Unit Modulating Economizer Installation Instructions

Package Unit Modulating Economizer Installation Instructions Package Unit Modulating Economizer Installation Instructions Downflow Unit Warning: Recognize this symbol as an indication of Important Safety Information! Read all instructions prior to installation.

More information

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

ZIP Economizer Fault Detection and Diagnostics (FDD) Table Fault Detection and Diagnostics (FDD) Table Fault Detection Problem Diagnostic ction (in addition to alarm stored / transmitted) Potential Cause C Fault Code OT sensor predetermined range O damper returns

More information

Installation Instructions

Installation Instructions 020A02 021A03 008C00 SMALL ROOFTOP UNITS VERTICAL ECONOMI$ER IV ACCESSORY 2to12-1 / 2 TONS LARGE ROOFTOP UNITS VERTICAL AND HORIZONTAL ECONOMI$ER IV ACCESSORY 13 to 25 TONS Installation Instructions TABLE

More information

Installation Instructions

Installation Instructions 024A02 025A02 SMALL ROOFTOP UNITS HORIZONTAL ECONOMI$ER IV ACCESSORY 2TO12-1/2TONS Installation Instructions TABLE OF CONTENTS PACKAGE CONTENTS... 1 PACKAGE USAGE... 1 SAFETY CONSIDERATIONS... 1 GENERAL...

More information

ZHA/ZHB SERIES WARNING

ZHA/ZHB SERIES WARNING Service Literature Corp. 09-L Revised 7-08 ZHA/ZHB SERIES, 4, 5 and 6 ton 0.6 to kw ZHA/ZHB06, 048, 060, 07 The ZHA/ZHB packaged electric heat pump units are available in standard cooling efficiency (06S,

More information

PTAC CONTROL BOARD KIT RSKP0006 INSTALLATION INSTRUCTIONS

PTAC CONTROL BOARD KIT RSKP0006 INSTALLATION INSTRUCTIONS PTAC CONTROL BOARD KIT RSKP0006 INSTALLATION INSTRUCTIONS Description Control board installation procedures are described in detail in these instructions. Read and follow these instructions carefully before

More information

Installation Instructions

Installation Instructions CRPWREXH068A00 CRPWREXH069A00 CRPWREXH070A00 POWER EXHAUST ACCESSORY SINGLE PACKAGE ROOFTOP UNITS 15 to 25 TONS Installation Instructions TABLE OF CONTENTS SAFETY CONSIDERATIONS... 1 GENERAL... 1 INSTALLATION...

More information

F SERIES. Floor Exposed Vertical Fan Coil Units. Nominal Sizes 200 thru 1200 CFM

F SERIES. Floor Exposed Vertical Fan Coil Units. Nominal Sizes 200 thru 1200 CFM Producing Quality Heating & Cooling Equipment For Over 5 Years F SERIES Floor Exposed Vertical Fan Coil Units Nominal Sizes thru 1 CFM MAGIC AIRE F SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN

More information

Installation Instructions

Installation Instructions CRLOWAMB039A00 CRLOWAMB040A00 CRTRXKIT002A00 ACCESSORY MOTORMASTER I HEAD PRESSURE CONTROL KIT 12.5 TON HEAT PUMP Installation Instructions TABLE OF CONTENTS PACKAGE CONTENTS... 1 PRODUCT USAGE... 2 SAFETY

More information

Predator Model Number Nomenclature

Predator Model Number Nomenclature DM, DH 6.5, 7.5, 8.5, 10.0, 12.5 Ton Single Package Air Conditioner HVAC SERVICE PARTS Supersedes: 035-17288-000 Rev A (800) 035-17288-001-A-0804 Predator Model Number Nomenclature 1 of 16 D H 120 N 20

More information

Installation Instructions

Installation Instructions ROOFTOP UNITS, 3 to 25 TONS ACCESSORY TEMPERATURE FOR SINGLE OR DIFFERENTIAL DRY BULB CONTROL FOR ECONOMI$ERt IV Installation Instructions TABLE OF CONTENTS PACKAGE CONTENTS... 1 SAFETY CONSIDERATIONS...

More information

WIRING DIAGRAMS FA4C FY4A FC4D FX4C FH4C

WIRING DIAGRAMS FA4C FY4A FC4D FX4C FH4C FAN COILS ACCESSORY ELECTRIC HEATERS WIRING DIAGRAMS FIG. FIELD --- INSTALLED HEATER MODEL FAC FYA FCD FXC FHC 1 KFCEH001N03 01--- 0 01--- 0 01--- 0 01--- 0 001 1 KFCEH0501N05 01--- 060 01--- 060 01---

More information

POWER TRIM 5 E DUAL POWER TRIM CONTROL

POWER TRIM 5 E DUAL POWER TRIM CONTROL POWER TRIM 5 E 22129 DUAL POWER TRIM CONTROL Table of Contents Page Important information..................... 5E-1 Testing Dual Power Trim System........... 5E-1 Relay Test............................

More information

Package Unit Modulating Economizer Installation Instructions

Package Unit Modulating Economizer Installation Instructions Package Unit Modulating Economizer Installation Instructions Downflow Unit Warning: Recognize this symbol as an indication of Important Safety Information! Read all instructions prior to installation.

More information

DZ14S Commercial 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A

DZ14S Commercial 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A DZ14S Commercial Cooling Capacity: 34,600 to 56,500 BTU/h Heating Capacity: 32,800 to 59,000 BTU/h 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A Contents Nomenclature...2 Product Specifications...3

More information

Parts Information. Commercial Microwave Oven

Parts Information. Commercial Microwave Oven Parts Information Commercial Microwave Oven Important notes: This is an uncontrolled document. There is no record of its distribution and no corrections will be provided. Models and Manufacturing numbers

More information

PHR5. Product Specifications

PHR5. Product Specifications PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R

More information

Installation, Start-Up and Configuration Instructions

Installation, Start-Up and Configuration Instructions Installation, Start-Up and Configuration Instructions CONTENTS Page SAFETY CONSIDERATIONS...................... 1 GENERAL.......................................1,2 INSTALLATION................................

More information

WIRING DIAGRAM SYMBOLS

WIRING DIAGRAM SYMBOLS WIRING DIAGRAM SYMBOLS Article Text 1989 Toyota MR2 For Ace Mechanics 123 Main Street San Diego Ca 92126 Copyright 1997 Mitchell International Friday, November 28, 2003 09:15AM ARTICLE BEGINNING WIRING

More information

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h // Heating Input : 40,000 140,000 BTU/h Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...

More information

TCA WARNING CAUTION. TCA 15 through 25 ton ROOFTOP UNITS. Service Literature

TCA WARNING CAUTION. TCA 15 through 25 ton ROOFTOP UNITS. Service Literature TCA ROOFTOP UNITS Service Literature TCA 180 210 240 300 (10 08) The TCA180S, 180H, 210S, 210H, 240S, 240H and 300S are available in one cabinet size with cooling capacities from 180,000 to 286,000 Btuh

More information

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components AFGP12B Gas/Electric Package Unit Features Shipped for horizontal applications; easily converted to downshot Side-by-side horizontal discharge Standard thermostatic expansion valve Crimp-Tite weld-free

More information

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16 SOUND REFRIGERANT ENVIRONMENTALLY Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE GAS / ELECTRIC, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS 50FP-1SB 50FP034, 038, 044, 048, 054, 064, 074 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE FACTORY-INSTALLED OPTIONAL ELECTRIC HEAT

More information

ARUF Series Multi-Position

ARUF Series Multi-Position Series Multi-Position Multi-speed Psc Motor Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed PSC blower motor All-aluminum evaporator coil Coil mounting

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION FORM# 609A-0808 (609A-0298) I - SHIP PING AND PACK ING LIST Package 1 of 1 contains: 1 - Economizer Assembly 1 - Fresh Air Hood w/ Filter 1 - Control Package 1 - Barometric Relief Hood 1 - Filter Access

More information

Parts List, Tech Labels, Wiring Diagrams

Parts List, Tech Labels, Wiring Diagrams Parts List, Tech Labels, Wiring Diagrams PHE072-120 SERIES PACKAGE HEAT PUMP UNITS TABLE OF CONTENTS PARTS LIST----------- 2-10 PARTS DRAWING - - - - - 11-14 CHARGING CHARTS - - 15-18 WIRING DIAGRAMS -

More information

DX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h

DX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h DX11S Commercial Standard Features Energy-efficient compressor Quiet operating top discharge High-efficiency copper tube / aluminum fin coil Brass liquid and suction service valves High- and low-pressure

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

Installation Instructions

Installation Instructions Installation Instructions Part No. 50DJ902791 48/50FP,JP,MP,NP 50FPX,FPY,JPX,JPY 50FB,JB,NB Accessory Outdoor-Air Cfm Kit CONTENTS GENERAL........................................ 1 INSTALLATION................................

More information

INSTALLATION INSTRUCTIONS ECOHLX Series Horizontal Economizer and PEHALX Series Economizer with Power Exhaust for York LX Series. Warning.

INSTALLATION INSTRUCTIONS ECOHLX Series Horizontal Economizer and PEHALX Series Economizer with Power Exhaust for York LX Series. Warning. Before Starting Installation Warning Shut power to unit prior to any work being done. Personal injury or death could result. Only qualified HVAC service personnel should install, troubleshoot, repair or

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS 50FN-1SB 50FNX,FNY078,088,104 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE AIR VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE WITH INTEGRAL ECONOMIZER AND HIGH-CAPACITY MODULATING

More information

Installation Instructions

Installation Instructions MotorMaster ontrol Kit for Residential Split System Applications ancels: IIK 561-18-1 IIK 561-18-2 9-97 Installation Instructions Part No. 32LT660004 and 005 NOTE: Read the entire instruction manual before

More information

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h / Heating Input : 40,000 100,000 BTU/h Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...

More information

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012 COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES 506953-01 3/2014 Supersedes 8/2012 Litho U.S.A. MSAV Supply Air Blower VFD Kit INSTALLATION INSTRUCTIONS FOR MSAV (MULTI-STAGE AIR VOLUME) SUPPLY AIR BLOWER

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

Installation Instructions

Installation Instructions HH57AC078 CRENTDIF004A00 ROOFTOP UNITS, 2 to 25 TONS ACCESSORYENTHALPYAND DIFFERENTIAL ENTHALPY FOR ECONOMI$ERt IV Installation Instructions TABLE OF CONTENTS PACKAGE CONTENTS - HH57AC078... 1 PACKAGE

More information

TRI-CAPACITY PACKAGE UNIT

TRI-CAPACITY PACKAGE UNIT TECHNICAL SELECTION TRI-CAPACITY PACKAGE UNIT +50 o C -10 o C 3 THREE PHASE TRI-CAPACITY EC PLUG FAN LOUVRE LOW NOISE FAN UNIT FEATURES Compliant Scroll Compressors Tri-Capacity 33% 67% 100% Capacity Stages

More information

Parts List Charging Charts & Wiring Diagrams

Parts List Charging Charts & Wiring Diagrams Parts List Charging Charts & Wiring Diagrams Models PGE300H275A PGE300L275A PGE300H360A PGE300L360A PGE300S360A Table of Contents Page Parts Drawings 2 to 7 Parts list 8 to 13 Charging data 14 & 15 Wiring

More information

Installation Instructions

Installation Instructions KALA0601AAA KALA0701AAA MotorMasterR Low Ambient Controller for Residential plit ystem Applications Installation Instructions Fig. 1 - MotorMasterr Low Ambient Controller A93157 NOTE: Read the entire instruction

More information

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h / ADSS8 Heating Input: 40,000 140,000 BTU/h Single-Stage Multi-Speed Gas Furnaces 80% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...7 Wiring Diagrams...10 Accessories...11

More information

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CHS Product Specifications COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on 0 to 121 models, two stage cooling

More information

AMS8/ADSS8. Single-Stage. Heating Input: 40, ,000 BTU/h

AMS8/ADSS8. Single-Stage. Heating Input: 40, ,000 BTU/h Heating Input: 40,000 140,000 BTU/h /ADSS8 Single-Stage Multi-Speed Gas Furnaces 80% AFUE Standard Features Single-stage gas valve Durable Silicon Carbide ignitor Quiet, single-speed draft inducer Self-diagnostic

More information

14 SEER, 12 EER PACKAGE AIR CONDITIONER, 2 to 5 TONS 208/ Single Phase

14 SEER, 12 EER PACKAGE AIR CONDITIONER, 2 to 5 TONS 208/ Single Phase COMMERCIAL SOUND REFRIGERANT ENVIRONMENTALLY PAD4 Product Specifications 14 SEER, 12 EER PACKAGE AIR CONDITIONER, 2 to 5 TONS 208/230 1 60 Single Phase REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

Installation Instructions

Installation Instructions Part Number: CPECOMZR011A00 & CPECOMZR012A00 Installation Instructions Read these instructions completely before attempting to install the Horizontal Accessory. CONTENTS SAFETY CONSIDERATIONS...1 GENERAL...1,2

More information

Installation Instructions Read these instructions completely before attempting to install the Vertical EconoMi$er X Accessory.

Installation Instructions Read these instructions completely before attempting to install the Vertical EconoMi$er X Accessory. CRECOMZR076A00 CRECOMZR078A00 CRECOMZR080A00 Installation Instructions Read these instructions completely before attempting to install the Vertical EconoMi$er X Accessory. CONTENTS SAFETY CONSIDERATIONS..............

More information

GMS8/GDS8/GHS8 Multi-Position, Multi-Speed Gas Furnaces

GMS8/GDS8/GHS8 Multi-Position, Multi-Speed Gas Furnaces Heating Input: 40,000 140,000 TU/h //GHS8 Multi-Position, Multi-Speed Gas Furnaces 80% AFUE Standard Features Dual-diameter tubular heat exchanger Single-stage combination redundant gas valve Norton hot

More information

Installation Instructions

Installation Instructions Part Number: CPECOMZR008A00 & CPECOMZR009A00 Installation Instructions Read these instructions completely before attempting to install the Vertical Accessory. CONTENTS SAFETY CONSIDERATIONS...1 GENERAL...1,2

More information

RP6.52Y (ERRATA 1) (202) 2 of 12

RP6.52Y (ERRATA 1) (202) 2 of 12 530.18-RP6.52Y (ERRATA 1) (202) 2 of 12 ELECTRICAL (Cont.) FIG ITEM UNIT D4CG150N16525 D4CG150N16546 D4CG150N16558 DESCRIPTION STYLE 5-BURNER 5-BURNER 5-BURNER * 18 CONNECTOR, CAP (6-CIRCUIT) 025-20963-000

More information

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018 Replacement Parts List No. 700052400 Revision D 01/2018 Daikin SmartSource Compact Vertical Water Source Heat Pump WGCV 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on

More information

Comfort Pack Archived Part Lists PARTS LISTS

Comfort Pack Archived Part Lists PARTS LISTS Comfort Pack Archived Part Lists PARTS LISTS CPGXX38-X Description 14208336 Natural Gas Orifice - 38 14208343 LP Gas Conversion Kit - 38 14208329 Heat Exchanger Assembly - 38 14208332 Full Burner Body

More information

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A Temperature Control Panel Wiring Diagram Model: ISPA-0-P-5A Shift Controls, Inc. Installed Options: TC Jack Panel Connector Interlock Relay, RLY- 5A Power Cord www.shift-controls.com support@shift-controls.com

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS (1100) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H3CE180 & 240 15 AND 20 NOMINAL TONS DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at the factory to provide one-piece

More information

Installation Instructions

Installation Instructions CRECOMZR077A00 CRECOMZR079A00 CRECOMZR08A00 Small Rooftop Products 3 to 2 ½ Tons Horizontal EconoMi$er X Accessory Read these instructions completely before attempting to install the Horizontal EconoMi$er

More information

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( ) 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION 0 F LOW AMBIENT ACCESSORY MODELS 2LA04703425, 3546 & 3658 (208, 230, 460 & 575 VOLT APPLICATIONS) Supersedes: 530.18-N5.6V (1091) 530.18-N5.6V (1193) FOR 15, 20 & 25 TON COOLING

More information

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGAA SERIES 10 SEER C CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Efficiency: PGAA - 10 SEER. Combination gas heating and electric cooling, self-contained for year-round comfort. Systems

More information

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h / Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40,000 140,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...8 Wiring Diagram...10 Accessories...11

More information

REPAIR PART INSTALLATION INSTRUCTIONS

REPAIR PART INSTALLATION INSTRUCTIONS REPAIR PART INSTALLATION INSTRUTIONS ONTROL REPAIR KIT FOR (S1-37323870001) ODELS E*FH / E*EB / E*S 361816-UAI-A-0208 FIGURE 1: Demand Defrost ontrol odule GENERAL The YorkGuard VI Demand Defrost control

More information

Installation Instructions

Installation Instructions Single Package Rooftop Cooling Only Sizes 0 --- 07 with Puronr (R---10A) Refrigerant Installation Instructions NOTE: Read the entire instruction manual before starting the installation TABLE OF CONTENTS

More information

B2HZ SERIES - 13 SEER SINGLE PACKAGED HEAT PUMPS (R-410A, STYLE A,B)

B2HZ SERIES - 13 SEER SINGLE PACKAGED HEAT PUMPS (R-410A, STYLE A,B) www.source1parts.com HVAC SERVICE PARTS B2HZ SERIES - 13 SEER SINGLE PACKAGED HEAT PUMPS (R-410A, STYLE A,B) Supersedes:Nothing 035-23152-001 Rev. A (0212) 1 of 10 74 73 70 72 71 80 76 66 77 68 69 67 78

More information

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA: Supersedes: 160.55-PW4 (1199) FORM 160.55-PW4 (600) PRODUCT DRAWING YORK INTERNATIONAL CORPORATION P.O. Box 1592, YORK, PA 17405 CONTRACTOR ORDER NO. YORK CONTRACT NO. YORK ORDER NO. WIRING DIAGRAM FIELD

More information

ELECTRICAL / GENERAL INFORMATION

ELECTRICAL / GENERAL INFORMATION ELECTRICAL / GENERAL INFORMATION General Information Reading Electrical Schematics The schematic is made up of individual circuits laid out in a sequence of related functions. It is formatted with all

More information

RHS. Product Specifications. PACKAGE HEAT PUMP UNIT R 410A SINGLE PACKAGE ROOFTOP TONS (1 & 3 Phase)

RHS. Product Specifications. PACKAGE HEAT PUMP UNIT R 410A SINGLE PACKAGE ROOFTOP TONS (1 & 3 Phase) RHS Product Specifications PACKAGE HEAT PUMP UNIT R 410A SINGLE PACKAGE ROOFTOP 3 12.5 TONS (1 & 3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, single packaged heat pump units that are

More information

Installation Instructions

Installation Instructions Part Number: CPECOMZR010A00 Read these instructions completely before attempting to install the Vertical Accessory. CONTENTS SAFETY CONSIDERATIONS...1 GENERAL...1,2 ACCESSORIES LIST...2 INSTALLATION...2-6

More information

INSTALLATION INSTRUCTIONS MODELS (-)XRD-PDCM3 & (-)XRD-SDCM3 VERTICAL AIRFLOW ECONOMIZERS

INSTALLATION INSTRUCTIONS MODELS (-)XRD-PDCM3 & (-)XRD-SDCM3 VERTICAL AIRFLOW ECONOMIZERS WARNING INSTALLATION INSTRUCTIONS MODELS (-)XRD-PDCM3 & (-)XRD-SDCM3 VERTICAL AIRFLOW ECOMIZERS THIS ACCESSORY IS TO BE INSTALLED BY A QUALIFIED, LICENSED SERVICE PERSON. TO AVOID UNSATISFACTORY OPERATION

More information

TECHNICAL SUPPORT MANUAL Split System Heat Pump R2HM, R2H3, WCH3**2

TECHNICAL SUPPORT MANUAL Split System Heat Pump R2HM, R2H3, WCH3**2 TECHNICAL SUPPORT MANUAL Split System Heat Pump R2HM, R2H3, WCH3**2 DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness.

More information

LB LOAD BANK MANUAL CONTAINS OPERATING INSTRUCTIONS PARTS LIST WIRING DIAGRAMS SERVICE INSTRUCTIONS

LB LOAD BANK MANUAL CONTAINS OPERATING INSTRUCTIONS PARTS LIST WIRING DIAGRAMS SERVICE INSTRUCTIONS LB-60-30 LOAD BANK MANUAL CONTAINS OPERATING INSTRUCTIONS PARTS LIST WIRING DIAGRAMS SERVICE INSTRUCTIONS 4031 W Kiehnau Ave Milwaukee, WI 53209 CAUTION THIS LOAD BANK IS DESIGNED FOR THE TESTING AND SERVICING

More information

XENON POWER SUPPLY 4000 Watt Gladiator IV

XENON POWER SUPPLY 4000 Watt Gladiator IV XENON POWER SUPPLY 4000 Watt Gladiator IV 220 Volt Equipment Type 62-00049 Rev. February 2003 STRONG INTERNATIONAL a division of Ballantyne of Omaha, Inc. 4350 McKinley Street Omaha, Nebraska 68112 USA

More information

HIGH EFFICIENCY PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP TONS

HIGH EFFICIENCY PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP TONS RGH Product Specifications HIGH EFFICIENCY PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP 3 12.5 TONS [1 & 3 Phase] BUILT TO LAST, EASY TO INSTALL AND SERVICE R-410A HFC refrigerant

More information

DD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h

DD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE Heating Input: 40,000 100,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...4 Airflow Data...5 Wiring Diagram...7 Accessories...8

More information

Corp L3 Revised CB17/CBH17 SERIES UNITS SPECIFICATIONS CB17-95V CBH17-95V

Corp L3 Revised CB17/CBH17 SERIES UNITS SPECIFICATIONS CB17-95V CBH17-95V Service Literature Corp. 0002 L3 Revised 08 2004 CB17/CBH17 SERIES UNITS CB17 Lennox CB17 and CBH17 model blower coil units, designed for indoor applications only, are available in two models; CB17 series

More information

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996 Replacement s List No. 055236800 Revision C 11/2016 McQuay Climate Control Commercial Unitary Rooftop CUR 075-150 Vintage F Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

MARINE / INDUSTRIAL SINGLE PACKAGE COOLING UNIT. Marine Systems 90MA/MU SERIES 3. CARRIER CORPORATION RevC

MARINE / INDUSTRIAL SINGLE PACKAGE COOLING UNIT. Marine Systems 90MA/MU SERIES 3. CARRIER CORPORATION RevC Marine Systems MARINE / INDUSTRIAL SINGLE PACKAGE COOLING UNIT SERIES 3 CARRIER CORPORATION 2009 62-114 85 RevC INTRODUCTION This Parts List identifies service replacement parts for the Carrier Marine

More information

Easy Start. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual

Easy Start. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual Easy Start 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter Installation Manual Micro Air Corporation Phone (609) 259-2636 124 Route 526. www.microair.net Allentown NJ 08501 Fax (609) 259-6601 Retrofit

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42801-.pdf for the current revision. Package Gas-Electric - Commercial Table of Contents Model

More information

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit RD-90EB RO-90EPB C O N T E N T S SPECIFICATIONS... OUTLINE AND DIMENSIONS... CIRCUIT DIAGRAM...5 REFRIGERANT SYSTEM DIAGRAM...6

More information