TABLE OF CONTENTS REYHQ16-24P

Size: px
Start display at page:

Download "TABLE OF CONTENTS REYHQ16-24P"

Transcription

1 Outdoor Units VRV HEAT RECOVERY REYHQ6-2P TABLE OF CONTENTS REYHQ6-2P Specifications Independent Unit Technical Specifications Electrical Specifications (50Hz) Electrical data Options Capacity tables Combination table Cooling capacity tables Heating capacity tables Capacity correction factor Dimensional drawing & centre of gravity Dimensional drawing Centre of gravity Piping diagram Wiring diagram Wiring diagram Sound data Sound pressure spectrum Sound power spectrum Installation Service space Fixation and foundation of units Refrigerant pipe selection Operation range VRV Systems Outdoor Units

2 i t t - r t Specifications Outdoor Units VRV HEAT RECOVERY REYHQ6-2P e s R mn P e U 2 as 6eoy Ho S Q d H V Y Ru E O RV - INDEPENDENT UNIT REYHQ6PYB REYHQ20PYB REYHQ22PYB REYHQ2PYB Outdoor Unit REMQ8P9YB REMQ8P9YB REMQ0P8YB REMHQ2P8YB REMQ8P9YB REMHQ2P8YB REMHQ2P8YB REMHQ2P8YB -2 TECHNICAL SPECIFICATIONS REYHQ6PYB REYHQ20PYB REYHQ22PYB REYHQ2PYB Capacity Cooling kw Heating kw COP Cooling Heating Capacity range HP Power input Cooling kw (nominal)(50hz ) Heating kw PED category Category II Max n of indoor units to be connected Indoor index Minimum connection Maximum Casing Colour Daikin White Material Painted galvanised steel Heat Dimensions Length mm,778 +,778, ,088, ,088 2, ,088 Exchanger Nr of Rows Fin Pitch mm Nr of Passes Face Area m² Nr of Stages Tube type Hi-XSS (8) Fin Fin type Non-symmetric waffle louvre Treatment Hydrophylic and anti corrosion resistant Fan Type Propeller Quantity 2 Air Flow Rate Cooling m³/min (nominal at 20V) cfm Fan External static pressure Pa 78 Pa in high static pressure Discharge direction Vertical Motor Quantity 2 Model Brushless DC Output motor W x50 2x50 + 2x50 Compressor Quantity 2 Motor Quantity Model Inverter Type Hermetically sealed scroll compressor Speed rpm 7, ,980 7, ,00 6,00 + 6,00 6,00 + 6,00 Motor kw Output Crankcas W e Heater Quantity + + Model ON - OFF ON - OFF ON - OFF Type Hermetically sealed scroll compressor Hermetically sealed scroll compressor Hermetically sealed scroll compressor Speed rpm 2,900 2, ,900 2, ,900 Motor kw Output Crankcas W e Heater Cooling Standard Min CDB VRV Systems Outdoor Units

3 Specifications Outdoor Units VRV HEAT RECOVERY REYHQ6-2P -2 TECHNICAL SPECIFICATIONS REYHQ6PYB REYHQ20PYB REYHQ22PYB REYHQ2PYB Operation Cooling Max CDB Range Heating Min CWB Max CWB Sound level Cooling Sound dba Power (Nominal) Sound Pressure (Nominal) dba Refrigerant Name R-0A Charge kg Control Expansion valve (electronic type) Nr of Circuits Refrigerant Oil Name Synthetic (ether) oil Charged Volume l Piping Liquid (OD) Type Braze connection connections Diameter (OD) mm Gas Type Braze connection Diameter (OD) mm Heat Insulation Both liquid and gas pipes Max total length m,000 Defrost Method Reversed cycle Defrost Control Sensor for outdoor heat exchanger temperature Capacity Control Method Inverter controlled Capacity Control ~ 00 Safety devices HPS Fan motor driver overload protector Over current relay Inverter overload protector PC board fuse Standard Standard Accessories Installation manual Accessories Quantity Standard Accessories Operation manual Quantity Standard Accessories Connection pipes Quantity Notes Nominal cooling capacities are based on : indoor temperature : 27 CDB, 9 CWB, outdoor temperature : 5 CDB, equivalent refrigerant piping : 7.5m, level difference : 0m. Nominal heating capacities are based on : indoor temperature : 20 CDB, outdoor temperature : 7 CDB, 6 CWB, equivalent refrigerant piping : 7.5m, level difference : 0m Sound pressure Sound values Sound values are measured in a semi-anechoic room. - ELECTRICAL SPECIFICATIONS (50HZ) REYHQ6PYB REYHQ20PYB REYHQ22PYB REYHQ2PYB Power Supply Name Y Phase N~ Frequency Hz Voltage V 80-5 VRV Systems Outdoor Units 2

4 Specifications Outdoor Units VRV HEAT RECOVERY REYHQ6-2P - ELECTRICAL SPECIFICATIONS (50HZ) REYHQ6PYB REYHQ20PYB REYHQ22PYB REYHQ2PYB Current Nominal running current (RLA) Cooling A Starting current (MSC) A Z-max Text Minimum Ssc value kva 2,6 2,2 2,02 2,228 Minimum circuit amps A (MCA) Maximum fuse amps (MFA) A Full load amps (FLA) A Voltage range Minimum V Maximum V Wiring connections Power Supply Intake Notes For Power Supply For connection with indoor Quantity Remark Earth wire include Quantity Remark F - F2 Both indoor and outdoor unit MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker) MSC means the maximum current during start up of the compressor Maximum allowable voltage range variation between phases is 2% RLA is based on following conditions : indoor temperature : 27 CDB/9 CWB, outdoor temperature : 5 CDB Select wire size based on the value of MCA or TOCA TOCA means the total value of each OC set Voltage range : units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits In accordance with EN/IEC (), respectively EN/IEC (2), it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys() <= Zmax, respectively Ssc() >= minimum Ss VRV Systems Outdoor Units

5 2 Electrical data Outdoor Units VRV HEAT RECOVERY REYHQ6-2P REYHQ-P Coombination of Minimum S sc value [kva] Z max [ ] REYHQ6P REMQ8P9 + REMQ8P REYHQ20P REMQ8P9 + REMQ2P8 22 0,27 REYHQ22P REMQ0P8 + REMHQ2P ,25 REYHQ2P REMHQ2P8 + REMHQ2P ,2 2 NOTES In accordance with EN/IEC (), respectively EN/IEC (2), it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Z () sys Z max, respectively S () sc minimum S sc value () 2 European/International technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated 75A. (2) European/International technical standard setting the limits for harmonic currents produced by equipment connected to public lowvoltage system with input current 6A and 75A per phase. () Short-circuit power () System impedance. TW8-A VRV Systems Outdoor Units

6 Outdoor Units VRV HEAT RECOVERY REYHQ6-2P Options REYHQ-P Wind cover (See note 5) REYQ8~8P+REYHQ6,20,22,2P Multi combination of REMQ~6P+REMHQ2P Description REMQ8P9 REMQ0P8 REMQ2P9 REMHQ2P9 REMQ6P8 2-unit multi -unit multi REMQP8 Refnet header KHRQ2M29H o o o o o o o KHRQ2M6H - - o o o o o KHRQ2M75H o o Refnet joint KHRQ2M20T o o o o o o o KHRQ2M29T9 o o o o o o o KHRQ2M6T - - o o o o o KHRQ2M75T o o Ountdoor unit multipiping connection kit for H/R BHFQ2P o - BHFQ2P o Central drain pan kit KWC26C280 o o o - - See note See note KWC26C o o See note See note Digital pressure gauge kit (See note 2) BHGP26A o o o o o - - BS box for H/R BSVQ00P o o o o o o o BSVQ60P o o o o o o o BSVQ250P o o o o o o o Central BSVQ box (See note 6) BSVQ00P o o o o o o o Sound reduction kit for BSVQ box (See note ) EKBSVQLNP o o o o o o o Full set REMQ8-2 KPS26C280 o o o Full set REMQ-6 + REMHQ2 KPS26C o o - - Top/discharge for REMQ8-2 KPS26C280T o o o - - See note See note Top/discharge for REMQ-6 + REMHQ2 KPS26C50T o o See note See note Left/suction for REMQ8-6 + REMHQ KPS26C50L o o o o o See note See note Right/suction for REMQ8-6 + REMHQ KPS26C50R o o o o o See note See note Rear/suction REMQ8-2P KPS26C280B o o o - - See note See note Rear/suction REMQ-6 + REMHQ2 KPS26C50B o o See note See note TW29- NOTES All options are kits 2 Only option per installation is needed. Only available for standard BSVQ boxes (not possible for central BSVQ). Allows to reduce operating sound of BSVQ-box (requires sound kit per BSVQ-box) To be combined based on the outdoor multi connection table. 5 Only required for technical cooling (outdoor temp < -5 C). 6 Factory pre-assembly of xbsvq00p 5 VRV Systems Outdoor Units

7 Outdoor Units VRV HEAT RECOVERY REYHQ6-2P Capacity tables - Combination table REYHQ-P UNIT REMQ8P9 REMQ0P8 REMHQ2P8 REYHQ6P 2 REYHQ20P REYHQ22P REYHQ2P 2 TW8- VRV Systems Outdoor Units 6

8 Capacity tables - 2 Cooling capacity tables Outdoor Units VRV HEAT RECOVERY REYHQ6-2P REYHQ6P Combination (%) Capacity index Outdoor air temp. ( CDB) TC: Total Capacity: kw ; PI: Power Input: kw (compressor + outdoor fan motor) Indoor air temperature: CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw kw kw 0% % % % TW82- NOTES - ANMERKUNGEN - - NOTAS - REMARQUES - NOTE - OPMERKINGEN - - NOTLAR The above table shows the average value of conditions which may occur. Die obige Tabelle zeigt den Durchschnittswert der Bedingungen, die auftreten können.. La tabla de arriba muestra el valor medio de condiciones que pueden ocurrir. Le tableau ci-dessus donne la valeur moyenne pour des conditions qui peuvent survenir. La tabella in alto mostra il valore delle condizioni medie che si possono riscontrare. De tabel hierboven geeft de gemiddelde waarde aan van situaties die kunnen voorvallen.,. Yukarıdaki tablo meydana gelebilecek ko ulların ortalama de erini göstermektedir. 7 VRV Systems Outdoor Units

9 Outdoor Units VRV HEAT RECOVERY REYHQ6-2P Capacity tables - 2 Cooling capacity tables REYHQ6P Combination (%) Capacity index Outdoor air temp. ( CDB) TC: Total Capacity: kw ; PI: Power Input: kw (compressor + outdoor fan motor) Indoor air temperature: CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw kw kw 90% % % % % TW82- VRV Systems Outdoor Units 8

10 Capacity tables - 2 Cooling capacity tables Outdoor Units VRV HEAT RECOVERY REYHQ6-2P REYHQ20P Combination (%) Capacity index Outdoor air temp. ( CDB) TC: Total Capacity: kw ; PI: Power Input: kw (compressor + outdoor fan motor) Indoor air temperature: CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw kw kw 0% % % % TW82- NOTES - ANMERKUNGEN - - NOTAS - REMARQUES - NOTE - OPMERKINGEN - - NOTLAR The above table shows the average value of conditions which may occur. Die obige Tabelle zeigt den Durchschnittswert der Bedingungen, die auftreten können.. La tabla de arriba muestra el valor medio de condiciones que pueden ocurrir. Le tableau ci-dessus donne la valeur moyenne pour des conditions qui peuvent survenir. La tabella in alto mostra il valore delle condizioni medie che si possono riscontrare. De tabel hierboven geeft de gemiddelde waarde aan van situaties die kunnen voorvallen.,. Yukarıdaki tablo meydana gelebilecek ko ulların ortalama de erini göstermektedir. 9 VRV Systems Outdoor Units

11 Outdoor Units VRV HEAT RECOVERY REYHQ6-2P Capacity tables - 2 Cooling capacity tables REYHQ20P Combination (%) Capacity index Outdoor air temp. ( CDB) TC: Total Capacity: kw ; PI: Power Input: kw (compressor + outdoor fan motor) Indoor air temperature: CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw kw kw 90% % % % % TW82- VRV Systems Outdoor Units 0

12 Capacity tables - 2 Cooling capacity tables Outdoor Units VRV HEAT RECOVERY REYHQ6-2P REYHQ22P Combination (%) Capacity index Outdoor air temp. ( CDB) TC: Total Capacity: kw ; PI: Power Input: kw (compressor + outdoor fan motor) Indoor air temperature: CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw kw kw 0% % % % TW82- NOTES - ANMERKUNGEN - - NOTAS - REMARQUES - NOTE - OPMERKINGEN - - NOTLAR The above table shows the average value of conditions which may occur. Die obige Tabelle zeigt den Durchschnittswert der Bedingungen, die auftreten können.. La tabla de arriba muestra el valor medio de condiciones que pueden ocurrir. Le tableau ci-dessus donne la valeur moyenne pour des conditions qui peuvent survenir. La tabella in alto mostra il valore delle condizioni medie che si possono riscontrare. De tabel hierboven geeft de gemiddelde waarde aan van situaties die kunnen voorvallen.,. Yukarıdaki tablo meydana gelebilecek ko ulların ortalama de erini göstermektedir. VRV Systems Outdoor Units

13 Outdoor Units VRV HEAT RECOVERY REYHQ6-2P Capacity tables - 2 Cooling capacity tables REYHQ22P Combination (%) Capacity index Outdoor air temp. ( CDB) TC: Total Capacity: kw ; PI: Power Input: kw (compressor + outdoor fan motor) Indoor air temperature: CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw kw kw 90% % % % % TW82- VRV Systems Outdoor Units 2

14 Capacity tables - 2 Cooling capacity tables Outdoor Units VRV HEAT RECOVERY REYHQ6-2P REYHQ2P Combination (%) Capacity index Outdoor air temp. ( CDB) TC: Total Capacity: kw ; PI: Power Input: kw (compressor + outdoor fan motor) Indoor air temperature: CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw kw kw 0% % % % TW82- NOTES - ANMERKUNGEN - - NOTAS - REMARQUES - NOTE - OPMERKINGEN - - NOTLAR The above table shows the average value of conditions which may occur. Die obige Tabelle zeigt den Durchschnittswert der Bedingungen, die auftreten können.. La tabla de arriba muestra el valor medio de condiciones que pueden ocurrir. Le tableau ci-dessus donne la valeur moyenne pour des conditions qui peuvent survenir. La tabella in alto mostra il valore delle condizioni medie che si possono riscontrare. De tabel hierboven geeft de gemiddelde waarde aan van situaties die kunnen voorvallen.,. Yukarıdaki tablo meydana gelebilecek ko ulların ortalama de erini göstermektedir. VRV Systems Outdoor Units

15 Outdoor Units VRV HEAT RECOVERY REYHQ6-2P Capacity tables - 2 Cooling capacity tables REYHQ2P Combination (%) Capacity index Outdoor air temp. ( CDB) TC: Total Capacity: kw ; PI: Power Input: kw (compressor + outdoor fan motor) Indoor air temperature: CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw kw kw 90% % % % % TW82- VRV Systems Outdoor Units

16 Outdoor Units VRV HEAT RECOVERY REYHQ6-2P Capacity tables - Heating capacity tables REYHQ6P Combination (%) Capacity index Outdoor air temp. TC: Total Capacity: kw ; PI: Power Input: kw (compressor + outdoor fan motor) Indoor air temperature: CDB TC PI TC PI TC PI TC PI TC PI TC PI CDB CWB kw kw kw kw kw kw kw kw kw kw kw kw 0% % % % TW82- NOTES - ANMERKUNGEN - - NOTAS - REMARQUES - NOTE - OPMERKINGEN - - NOTLAR is shown as reference. When selecting the unit models, avoid the Outdoor air temperature range shown by. dient als Verweis. Vermeiden Sie bei der Auswahl der Gerätemodelle den als markierten Temperaturbereich der Außenluft H. k, se muestra como referencia. Cuando seleccione los modelos de unidad, evite el intervalo de temperaturas del aire exterior indicado mediante est montré comme référence.lors du choix des modèles d'unités, évitez la plage de températures de l'air extérieur illustré par valori riportati unicamente come riferimento. Nel selezionare i modelli delle unità, non considerare i valori di temperatura dell'aria esterna indicati con il colore is als referentie getoond. Wanneer modellen van eenheden worden gekozen, vermijd dan het bereik van buitenluchttemperaturen geïllustreerd door., referans olarak gösterilmektedir. Ünite modellerini seçerken, belirtilen Dı hava sıcaklı ı aralı ından kaçının 2 The above table shows the average value of conditions which may occur. Die obige Tabelle zeigt den Durchschnittswert der Bedingungen, die auftreten können.. La tabla de arriba muestra el valor medio de condiciones que pueden ocurrir. Le tableau ci-dessus donne la valeur moyenne pour des conditions qui peuvent survenir. La tabella in alto mostra il valore delle condizioni medie che si possono riscontrare. De tabel hierboven geeft de gemiddelde waarde aan van situaties die kunnen voorvallen.,. Yukarıdaki tablo meydana gelebilecek ko ulların ortalama de erini göstermektedir. 5 VRV Systems Outdoor Units

17 Outdoor Units VRV HEAT RECOVERY REYHQ6-2P Capacity tables - Heating capacity tables REYHQ6P Combination (%) Capacity index Outdoor air temp. TC: Total Capacity: kw ; PI: Power Input: kw (compressor + outdoor fan motor) Indoor air temperature: CDB TC PI TC PI TC PI TC PI TC PI TC PI CDB CWB kw kw kw kw kw kw kw kw kw kw kw kw 90% % % % % TW82- VRV Systems Outdoor Units 6

18 Outdoor Units VRV HEAT RECOVERY REYHQ6-2P Capacity tables - Heating capacity tables REYHQ20P Combination (%) Capacity index Outdoor air temp. TC: Total Capacity: kw ; PI: Power Input: kw (compressor + outdoor fan motor) Indoor air temperature: CDB TC PI TC PI TC PI TC PI TC PI TC PI CDB CWB kw kw kw kw kw kw kw kw kw kw kw kw 0% % % % TW82- NOTES - ANMERKUNGEN - - NOTAS - REMARQUES - NOTE - OPMERKINGEN - - NOTLAR is shown as reference. When selecting the unit models, avoid the Outdoor air temperature range shown by. dient als Verweis. Vermeiden Sie bei der Auswahl der Gerätemodelle den als markierten Temperaturbereich der Außenluft H. k, se muestra como referencia. Cuando seleccione los modelos de unidad, evite el intervalo de temperaturas del aire exterior indicado mediante est montré comme référence.lors du choix des modèles d'unités, évitez la plage de températures de l'air extérieur illustré par valori riportati unicamente come riferimento. Nel selezionare i modelli delle unità, non considerare i valori di temperatura dell'aria esterna indicati con il colore is als referentie getoond. Wanneer modellen van eenheden worden gekozen, vermijd dan het bereik van buitenluchttemperaturen geïllustreerd door., referans olarak gösterilmektedir. Ünite modellerini seçerken, belirtilen Dı hava sıcaklı ı aralı ından kaçının 2 The above table shows the average value of conditions which may occur. Die obige Tabelle zeigt den Durchschnittswert der Bedingungen, die auftreten können.. La tabla de arriba muestra el valor medio de condiciones que pueden ocurrir. Le tableau ci-dessus donne la valeur moyenne pour des conditions qui peuvent survenir. La tabella in alto mostra il valore delle condizioni medie che si possono riscontrare. De tabel hierboven geeft de gemiddelde waarde aan van situaties die kunnen voorvallen.,. Yukarıdaki tablo meydana gelebilecek ko ulların ortalama de erini göstermektedir. 7 VRV Systems Outdoor Units

19 Outdoor Units VRV HEAT RECOVERY REYHQ6-2P Capacity tables - Heating capacity tables REYHQ20P Combination (%) Capacity index Outdoor air temp. TC: Total Capacity: kw ; PI: Power Input: kw (compressor + outdoor fan motor) Indoor air temperature: CDB TC PI TC PI TC PI TC PI TC PI TC PI CDB CWB kw kw kw kw kw kw kw kw kw kw kw kw 90% % % % % TW82- VRV Systems Outdoor Units 8

20 Outdoor Units VRV HEAT RECOVERY REYHQ6-2P Capacity tables - Heating capacity tables REYHQ22P Combination (%) Capacity index Outdoor air temp. TC: Total Capacity: kw ; PI: Power Input: kw (compressor + outdoor fan motor) Indoor air temperature: CDB TC PI TC PI TC PI TC PI TC PI TC PI CDB CWB kw kw kw kw kw kw kw kw kw kw kw kw 0% % % % TW82- NOTES - ANMERKUNGEN - - NOTAS - REMARQUES - NOTE - OPMERKINGEN - - NOTLAR is shown as reference. When selecting the unit models, avoid the Outdoor air temperature range shown by. dient als Verweis. Vermeiden Sie bei der Auswahl der Gerätemodelle den als markierten Temperaturbereich der Außenluft H. k, se muestra como referencia. Cuando seleccione los modelos de unidad, evite el intervalo de temperaturas del aire exterior indicado mediante est montré comme référence.lors du choix des modèles d'unités, évitez la plage de températures de l'air extérieur illustré par valori riportati unicamente come riferimento. Nel selezionare i modelli delle unità, non considerare i valori di temperatura dell'aria esterna indicati con il colore is als referentie getoond. Wanneer modellen van eenheden worden gekozen, vermijd dan het bereik van buitenluchttemperaturen geïllustreerd door., referans olarak gösterilmektedir. Ünite modellerini seçerken, belirtilen Dı hava sıcaklı ı aralı ından kaçının 2 The above table shows the average value of conditions which may occur. Die obige Tabelle zeigt den Durchschnittswert der Bedingungen, die auftreten können.. La tabla de arriba muestra el valor medio de condiciones que pueden ocurrir. Le tableau ci-dessus donne la valeur moyenne pour des conditions qui peuvent survenir. La tabella in alto mostra il valore delle condizioni medie che si possono riscontrare. De tabel hierboven geeft de gemiddelde waarde aan van situaties die kunnen voorvallen.,. Yukarıdaki tablo meydana gelebilecek ko ulların ortalama de erini göstermektedir. 9 VRV Systems Outdoor Units

21 Outdoor Units VRV HEAT RECOVERY REYHQ6-2P Capacity tables - Heating capacity tables REYHQ22P Combination (%) Capacity index Outdoor air temp. TC: Total Capacity: kw ; PI: Power Input: kw (compressor + outdoor fan motor) Indoor air temperature: CDB TC PI TC PI TC PI TC PI TC PI TC PI CDB CWB kw kw kw kw kw kw kw kw kw kw kw kw 90% % % % % TW82- VRV Systems Outdoor Units 20

22 Outdoor Units VRV HEAT RECOVERY REYHQ6-2P Capacity tables - Heating capacity tables REYHQ2P Combination (%) Capacity index Outdoor air temp. TC: Total Capacity: kw ; PI: Power Input: kw (compressor + outdoor fan motor) Indoor air temperature: CDB TC PI TC PI TC PI TC PI TC PI TC PI CDB CWB kw kw kw kw kw kw kw kw kw kw kw kw 0% % % % TW82- NOTES - ANMERKUNGEN - - NOTAS - REMARQUES - NOTE - OPMERKINGEN - - NOTLAR is shown as reference. When selecting the unit models, avoid the Outdoor air temperature range shown by. dient als Verweis. Vermeiden Sie bei der Auswahl der Gerätemodelle den als markierten Temperaturbereich der Außenluft H. k, se muestra como referencia. Cuando seleccione los modelos de unidad, evite el intervalo de temperaturas del aire exterior indicado mediante est montré comme référence.lors du choix des modèles d'unités, évitez la plage de températures de l'air extérieur illustré par valori riportati unicamente come riferimento. Nel selezionare i modelli delle unità, non considerare i valori di temperatura dell'aria esterna indicati con il colore is als referentie getoond. Wanneer modellen van eenheden worden gekozen, vermijd dan het bereik van buitenluchttemperaturen geïllustreerd door., referans olarak gösterilmektedir. Ünite modellerini seçerken, belirtilen Dı hava sıcaklı ı aralı ından kaçının 2 The above table shows the average value of conditions which may occur. Die obige Tabelle zeigt den Durchschnittswert der Bedingungen, die auftreten können.. La tabla de arriba muestra el valor medio de condiciones que pueden ocurrir. Le tableau ci-dessus donne la valeur moyenne pour des conditions qui peuvent survenir. La tabella in alto mostra il valore delle condizioni medie che si possono riscontrare. De tabel hierboven geeft de gemiddelde waarde aan van situaties die kunnen voorvallen.,. Yukarıdaki tablo meydana gelebilecek ko ulların ortalama de erini göstermektedir. 2 VRV Systems Outdoor Units

23 Outdoor Units VRV HEAT RECOVERY REYHQ6-2P Capacity tables - Heating capacity tables REYHQ2P Combination (%) Capacity index Outdoor air temp. TC: Total Capacity: kw ; PI: Power Input: kw (compressor + outdoor fan motor) Indoor air temperature: CDB TC PI TC PI TC PI TC PI TC PI TC PI CDB CWB kw kw kw kw kw kw kw kw kw kw kw kw 90% % % % % TW82- VRV Systems Outdoor Units 22

24 Capacity tables - Capacity correction factor REYHQ6P Outdoor Units VRV HEAT RECOVERY REYHQ6-2P Rate of change in cooling capacity Rate of change in heating capacity NOTES D0588A These figures illustrate the rate of change in capacity of a standard indoor unit system at maximum load (with the thermostat set to maximum) under standard conditions. Moreover, under partial load conditions there is only a minor deviation from the rate of change in capacity shown in the above figures. 2 With this outdoor unit, evaporating pressure constant control when cooling, and condensing pressure constant control when heating is carried out. Method of calculating A/C (cooling / heating) capacity: The maximum A/C capacity of the system will be either the total A/C capacity of the indoor units obtained from capacity characteristic table or the maximum A/C capacity of outdoor units as mentioned below, whichever smaller. Calculating A/C capacity of outdoor units Condition: Indoor unit combination ratio does not exceed 00% Maximum A./C capacity of outdoor units = A/C capacity of outdoor units obtained from performance characteristics table at the 00% combination x capacity change rate due to piping length to the farthest indoor unit Condition: Indoor unit combination ratio exceeds 00% Maximum A./C capacity of outdoor units = A/C capacity of outdoor units obtained from capacity characteristics table at the combination x capacity change rate due to piping length to the farthest indoor unit When overall equivalent pipe length is 90m or more, the diameter of the main liquid pipes (outdoor unit-branch sections) must be increased. When level difference is 50m or more, the diameter of the main gas and liquid pipes (outdoor unit-brach sections) must be increased. [Diameter of above case] Model Liquid REYQ6P9YB Ø5.9 *If available on the site, use this size. Otherwise, not increased. 5 When the main sections of the interunit liquid pipe diameters are increased the overall equivalent length should be calculated as follows. (Heating only) Overall equivalent length = Equivalent length to main pipe x Correction factor + Equivalent length after branching Choose a correction factor from the following table. Example in case of REYQ8PY Equivalent lenght Equivalent lenght Outdoor unit Liquid pipe: Standard size Branch BS-unit Indoor unit In the above case (Heating) Overall equivalent length = 80m x m = 6m The correction factor in capacity when Hp=0m is thus approximately.0 6 In combination wich does not include cooling onlyindoor unit. Calculate the equivalent length pipe by the following when you calculate cooling capacity Overall equivalent length = Equivalent length to main pipe x Equivalent length after branching Example Equivalent lenght Equivalent lenght Outdoor unit Branch BS-unit Indoor unit In the above case (Cooling) Overall equivalent length = 80m x m = 80m The correction factor in capacity when Hp=0m is thus approximately 0.88 EXPLANATION OF SYMBOLS H p : Level difference (m) between indoor and outdoor units where indoor unit in inferior position H M : Level difference (m) between indoor and outdoor units where indoor unit in superior position L : Equivalent pipe length (m) α : Rate of change in cooling / heating capacity [Diameter of pipe (standard size)] Model Liquid REYQ6P9YB Ø2.7 2 VRV Systems Outdoor Units

25 Outdoor Units VRV HEAT RECOVERY REYHQ6-2P Capacity tables - Capacity correction factor J J VRV Systems Outdoor Units 2

26 Capacity tables - Capacity correction factor REYHQ22P Outdoor Units VRV HEAT RECOVERY REYHQ6-2P Rate of change in cooling capacity Rate of change in heating capacity NOTES D0579B These figures illustrate the rate of change in capacity of a standard indoor unit system at maximum load (with the thermostat set to maximum) under standard conditions. Moreover, under partial load conditions there is only a minor deviation from the rate of change in capacity shown in the above figures. 2 With this outdoor unit, evaporating pressure constant control when cooling, and condensing pressure constant control when heating is carried out. Method of calculating A/C (cooling / heating) capacity: The maximum A/C capacity of the system will be either the total A/C capacity of the indoor units obtained from capacity characteristic table or the maximum A/C capacity of outdoor units as mentioned below, whichever smaller. Calculating A/C capacity of outdoor units Condition: Indoor unit combination ratio does not exceed 00% Maximum A./C capacity of outdoor units = A/C capacity of outdoor units obtained from performance characteristics table at the 00% combination x capacity change rate due to piping length to the farthest indoor unit Condition: Indoor unit combination ratio exceeds 00% Maximum A./C capacity of outdoor units = A/C capacity of outdoor units obtained from capacity characteristics table at the combination x capacity change rate due to piping length to the farthest indoor unit When overall equivalent pipe length is 90m or more, the diameter of the main liquid pipes (outdoor unit-branch sections) must be increased. When level difference is 50m or more, the diameter of the main gas and liquid pipes (outdoor unit-brach sections) must be increased. [Diameter of above case] Model Liquid REYQ8P9YB Ø2.7 REYQ22P8YB Ø9. *If available on the site, use this size. Otherwise, not increased. 5 When the main sections of the interunit liquid pipe diameters are increased the overall equivalent length should be calculated as follows. (Heating only) Overall equivalent length = Equivalent length to main pipe x Correction factor + Equivalent length after branching Choose a correction factor from the following table. Model Correction factor REYQ8P9YB 0.2 REYQ22P8YB 0. Example in case of REYQ22P8YB Equivalent lenght Equivalent lenght Outdoor unit Liquid pipe: Standard size Branch BS-unit Indoor unit In the above case (Heating) Overall equivalent length = 80m x m = 6m The correction factor in capacity when Hp=0m is thus approximately.0 6 In combination wich does not include cooling onlyindoor unit. Calculate the equivalent length pipe by the following when you calculate cooling capacity Overall equivalent length = Equivalent length to main pipe x Equivalent length after branching Example Equivalent lenght Equivalent lenght Outdoor unit Branch BS-unit Indoor unit In the above case (Cooling) Overall equivalent length = 80m x m = 80m The correction factor in capacity when Hp=0m is thus approximately 0.88 EXPLANATION OF SYMBOLS H p : Level difference (m) between indoor and outdoor units where indoor unit in inferior position H M : Level difference (m) between indoor and outdoor units where indoor unit in superior position L : Equivalent pipe length (m) α : Rate of change in cooling / heating capacity [Diameter of pipe (standard size)] Model Liquid REYQ8P9YB Ø9.5 REYQ22P8YB Ø VRV Systems Outdoor Units

27 Outdoor Units VRV HEAT RECOVERY REYHQ6-2P Capacity tables - Capacity correction factor H H B J H B J VRV Systems Outdoor Units 26

28 Outdoor Units VRV HEAT RECOVERY REYHQ6-2P 5 Dimensional drawing & centre of gravity 5 - Dimensional drawing REMHQ2P8 5 (Pitch of foundation bolt holes) (Pitch of foundation bolt holes) -5 x 22.5-mm-Oblong holes (foundation bolt hole) (DETAIL FOR FRONT SIDE) (knock-out hole) (knock-out hole) (knock-out hole) (DETAIL FOR BOTTOM SIDE) (knock-out hole): pressure equalizer pipe only. NOTES No. Parts name Remarks For piping connection method (front and bottom sides) see Pressure equalizer pipe 9. Brazing connection. the installation manual. connection port. See note 2 2 Piping connection diameter for field connection. (knock-out hole) shows the dimensions after fixing the accesory pipes. (knock-out hole) 5 Grounding terminal inside of switch box (M8) 6 Power cord routing hole (side) 62 No. Parts name Remarks 7 Power cord routing hole (front) 5 Liquid pipe connection port. 2.7 Brazing connection. 8 Power cord routing hole (front) 27 See note 2 9 Power cord routing hole (bottom) Suction gas pipe connection port Brazing connection. 0 Wire routing hole (front) 27 See note 2 Pipe routing hole (front) See note. High and low pressure gas pipe 22.2 Brazing connection. 2 Pipe routing hole (bottom) See note. connection port See note Pipe routing hole (bottom) 50 See note. D057585A H 2P8 G 27 VRV Systems Outdoor Units

29 Outdoor Units VRV HEAT RECOVERY REYHQ6-2P 5 Dimensional drawing & centre of gravity 5-2 Centre of gravity REMHQ2P8 5 Center of foundation bolt hole Center of foundation bolt hole Center of foundation bolt hole Center of foundation bolt hole (SLOT) Center of foundation bolt hole (SLOT) D057578B VRV Systems Outdoor Units 28

30 6 Piping diagram Outdoor Units VRV HEAT RECOVERY REYHQ6-2P H 2P8 J 6 29 VRV Systems Outdoor Units

31 Outdoor Units VRV HEAT RECOVERY REYHQ6-2P 7 Wiring diagram 7 - Wiring diagram REMHQ2P9 POWER SUPPLY 2 HP 7 TO IN/D UNIT TO OUT/D UNIT TO MULTI UNIT Note 5 indoor (F)(F2) outdoor (F)(F2) outdoor (0)(02) Male connector: BLU Female connector: WHT MALE CONNECTOR: BLK FEMALE CONNECTOR: WHT Position in switch box Position of M~C,M,2F El. compo. box Front layer Detail of MC~MC Detail of MC~MC Male conn: RED Female conn: WHT Indoor unit Magnetic relay VR Diode bridge (AP) Power module (AP,A8P) AP: Main AP,A8P: Fan KR: K2M (AP) KR: Y5S (A5P) V2R Power module (AP) AP~A8P A2P: Noise filter A5P: Sub K2R: KM (AP) K2R: Y6S (A5P) XA~XA Connector (MF, M2F) AP: Inverter A6P,A7P: Current sensor KR: YS (AP) KR: Y2S (AP) X5A Connector (YE) KR~KR Push button switch K5R: YS (AP) K5R: (for option) (A5P) XM Terminal strip (Power supply) BS~BS5 (Mode, Set, Return, Test, Reset) K6R: Y7S (A5P) K7R: EHC (AP) XM Terminal strip (Control) (AP) C, C6, C66 Capacitor K8R: E2HC (AP) K9R: EHC (AP) YE Electronic expansion valve (Main) EHC~EHC Crankcase heater KR: YS (AP) Y2E Electronic expansion valve (Charge) FU, F2U Fuse (T,.5A, 250V) (AP) QRP Reverse phase detection circuit YE Electronic expansion valve (Subcool) FU Fuse (T,.5A, 250V) (A5P) R0 Resistor (current sensor) (AP,A8P) Solenoid valve FU Fuse (8A, DC650V) (AP,A8P) R50, R59 Resistor YS: RMTG Y2S: way valve (pipe) F5U Field fusef R90 Resistor (current sensor) YS~YS YS: way valve (H/E Gas) F00U Fuse (T, 6A, 250V) (A2P) R95 Resistor (current limiting) YS: RMTL Y5S: Hots gas Pilotlamp (service monitor -orange) Thermistor Y6S: EV bypass Y7S: RMTO HP~H8P [H2P] Prepare, Test Flickering RT: Air (AP) RT: H/E Deicer ZC~Z0C Noise filter (ferrite core) Malfunction detection Light up RT~R9T RT: Fin (AP) R5T: Sub cool H/E gas ZF Noise filter (with surge absorber) HAP Pilotlamp (service monitor - orange) R2T: H/E Gas R6T: Sub cool H/E liq RT~RT K: Magnetic relay K2: Magnetic contactor (MC) RT: MC Discharge R7T: H/E Liquid Connector for optional parts K~K K: Magnetic relay K: Magnetic contactor (MC) R2T: M2C Discharge R8T: Suction X7A Operation output (A5P) K2M, KM Magnetic contactor (M2C, MC) RT: MC Discharge R9T: Liquid X9A Power supply (ADAPTER) (A5P) LR Reactor SNPH Pressure sensor (High) MC~MC Motor (Compressor) SNPL Pressure sensor (Low) MF, M2F Motor (Fan) SPH~SPH Pressure switch (High) PS Switching power supply (AP, AP) SD Safety devices input QDI Earth leakage breaker TA Current sensor (A6P, A7P) Rear layer : Terminal Colors: BLK: Black PNK: Pink ORG: Orange : Field wiring RED: Red BRN: Brown BLU: Blue : Connector YLW: Yellow GRY: Grey : Terminal WHT: White GRN: Green : Protective eart (screw) 2TW296-A NOTES When using the option adaptor, refer to the installation manual 2 Refer to the installation manual, for connection wiring to indoor-outdoor transmission F - F2, outdoor transmission F - F2, outdoor-multi transmission Q - Q2 and on how to use BS~BS5 and DS, DS2 switch. Do not operate the unit by short-circuiting protection device SPH~SPH VRV Systems Outdoor Units 0

32 8 Sound data 8 - Sound pressure spectrum Outdoor Units VRV HEAT RECOVERY REYHQ6-2P H 2P8 REYHQ-P 8 Sound power and pressure high cop (cooling) UNIT Sound Power Sound Pressure [dba] [dba] REYHQ6P REYHQ20P 85 6 REYHQ22P 85 6 REYHQ2P TW87-5 NOTE Sound power level is an absolute value that a sound source generates. 2 Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to sound level drawings. Mentioned values are theoretical values based on sound results of individually installed units. Possible deviations for sound values due to variety of installation patterns are not taken into account. VRV Systems Outdoor Units

33 Outdoor Units VRV HEAT RECOVERY REYHQ6-2P 8 Sound data 8-2 Sound power spectrum H 2P8 8 VRV Systems Outdoor Units 2

34 9 Installation 9 - Service space Outdoor Units VRV HEAT RECOVERY REYHQ6-2P REYHQ2P8 9 For single unit installation For installation in rows For centralized group layout <Pattern > <Pattern > <Pattern > 00 or more 00 or more 00 or more 0 or more <Front> 0 or more 0 or more 20 or more <Front> 20 or more 0 or more 500 or more 500 or more 0 or more <Front> 600 or more 20 or more 00 or more 0 or more 0 or more <Front> 20 or more 0 or more 500 or more <Front> <Pattern 2> 00 or more <Pattern 2> 00 or more 0 or more <Front> 500 or more 20 or more 0 or more 0 or more 00 or more 20 or more 0 or more 50 or more <Front> 50 or more 500 or more 50 or more 00 or more <Front> 500 or more 00 or more 50 or more <Pattern > 00 or more Wall height unrestricted <Pattern > Wall height unrestricted <Pattern 2> 00 or more 00 or more <Front> 00 or more 200 or more 200 or more <Front> 00 or more 50 or more <Front> 500 or more 00 or more 50 or more 50 or more <Front> 500 or more 00 or more <Front> 50 or more 50 or more <Front> 500 or more 00 or more 50 or more 50 or more 00 or more 00 or more 50 or more <Unit:mm> <Front> <Suction side> NOTES D055M Height of walls in case of Patterns and 2 Front: 500mm Suction side: 500mm Side: Height unrestricted. Installation space to be shown in this drawing is based on the cooling operation at 5 degrees outdoor air temperature. when the design outdoor air temperature exceeds 5 degrees or the load exceeds maximum ability because of much generation load of heat in all outdoor unit, take the suction side space more broadly than the space to be shown in this drawing. 2 If the above wall heights are exceeded then h2/2 and h/2 should be added to the front and suction side service spaces respectively as shown in the figure on the right. When installing the units most appropriate pattern should be selected from those shown above in order to obtain the best fit in the space available always bearing in mind the need to leave enough space for a person to pass between units and wall and for the air circulate freely. (If more units are to be installed than are catered for in the above patterns your layout should take account of the possibility of short circuits.) The units should be installed to leave insufficient space at the front for the on site refrigerant piping work to be carried out comfortably. VRV Systems Outdoor Units

Air Conditioners. Technical Data. VRV III heat recovery, with connection to heating only hydrobox REYAQ-P

Air Conditioners. Technical Data. VRV III heat recovery, with connection to heating only hydrobox REYAQ-P Air Conditioners Technical Data VRV III heat recovery, with connection to heating only hydrobox E E D E N 1 1-2 0 0 REYAQ-P Air Conditioners Technical Data VRV III heat recovery, with connection to heating

More information

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series Inverter cooling only / heat pump series RSX(Y)P5,8,10K7W1 RSX(Y)P-K7W1 1 Inverter cooling only / heat pump series 1 1 Specifications

More information

Air Conditioning. Technical Data. VRVIII-S heat pump EEDEN13-200_2 RXYSQ-P8Y1

Air Conditioning. Technical Data. VRVIII-S heat pump EEDEN13-200_2 RXYSQ-P8Y1 Air Conditioning Technical Data VRVIII-S heat pump EEDEN-200_2 RXYSQ-P8Y Outdoor Unit VRVIII-S heat pump RXYSQ-P8Y TABLE OF CONTENTS RXYSQ-P8Y Features.............................................................

More information

Air Conditioning. Technical Data. VRVIII-S heat pump EEDEN13-200_2 RXYSQ-P8V1

Air Conditioning. Technical Data. VRVIII-S heat pump EEDEN13-200_2 RXYSQ-P8V1 Air Conditioning Technical Data VRVIII-S heat pump EEDEN3-200_2 RXYSQ-P8V Outdoor Unit VRVIII-S heat pump RXYSQ-P8V TABLE OF CONTENTS RXYSQ-P8V Features.............................................................

More information

Heating Nom. dba Cooling Nom. dba Night quiet mode Level 1 dba Item Tie-wraps Tie-wraps Tie-wraps Tie-wraps

Heating Nom. dba Cooling Nom. dba Night quiet mode Level 1 dba Item Tie-wraps Tie-wraps Tie-wraps Tie-wraps RZQG71L8Y1B RZQG100L8Y1B RZQG125L8Y1B RZQG140L7Y1B Sound pressure level Heating Nom. dba 50 52 53 53 Cooling Nom. dba 48 50 51 52 Night quiet mode Level 1 dba 43 45 45 45 Standard Accessories Item Tie-wraps

More information

technical data air conditioning systems RQ-B7 Pair/Twin/Triple/Double Twin Application Split Sky Air

technical data air conditioning systems RQ-B7 Pair/Twin/Triple/Double Twin Application Split Sky Air technical data RQ-B7 Pair/Twin/Triple/Double Twin Application air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect

More information

Outdoor Units R-410A ARX-GV1B

Outdoor Units R-410A ARX-GV1B Outdoor Units R-40A ARX-GVB t A i n y U k BS r o AV t o0g i d- lt4x pur- SRAO 2 Specifications Outdoor Units R-40A ARX-GVB 2- NOMINAL CAPACITY AND NOMINAL INPUT ARX20GVB ARX25GVB ARX5GVB For combination

More information

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQA3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB TABLE OF CONTENTS FXDQ-A3 1 Features.............................................................

More information

Split-Sky Air RMX-JZ Super Multi Plus

Split-Sky Air RMX-JZ Super Multi Plus TECHNICAL DATA Split-Sky Air RMX-JZ Super Multi Plus Split Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment from the potential

More information

technical data air conditioning systems RYP-L7/B7 Pair Application Split Sky Air

technical data air conditioning systems RYP-L7/B7 Pair Application Split Sky Air technical data RYP-L7/B7 Pair Application air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the

More information

Air Conditioning. Technical Data. VRV IV water cooled series EEDEN RWEYQ-T8

Air Conditioning. Technical Data. VRV IV water cooled series EEDEN RWEYQ-T8 Air Conditioning Technical Data VRV IV water cooled series EEDEN15-201 Outdoor Unit TABLE OF CONTENTS 1 Features............................................................. 2 2 Specifications.......................................................

More information

1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units

1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units t i t l r - I Features s e Cs m B ne d E Ue V s 7 ya P os e oc Q dvn S nr ox VF C Reduction of power consumption of 20% (compared to FXSQ-M8 series) through use of new DC fan Improved comfort thanks to

More information

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air technical data RXG-C Wall Mounted, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human

More information

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems TABLE OF CONTENTS FXFQ-P9VEB 1 Specifications.......................................................

More information

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature

More information

Air Conditioning. Technical Data. Round flow cassette EEDEN FXFQ-A

Air Conditioning. Technical Data. Round flow cassette EEDEN FXFQ-A Air Conditioning Technical Data Round flow cassette EEDEN16-204 FXFQ-A TABLE OF CONTENTS FXFQ-A 1 Features............................................................. 2 2 Specifications.......................................................

More information

technical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air

technical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air technical data FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette Multi (950mm Split Heat x 950mm) Pump (edited) air conditioning systems Split Sky Air Outdoor Units R40A MXS-DAVMB_E2VB_E7VB Features V i

More information

Air Conditioners. Technical Data. Individual branch selector for VRV heat recovery (Individual BS box) EEDEN BSVQ P8

Air Conditioners. Technical Data. Individual branch selector for VRV heat recovery (Individual BS box) EEDEN BSVQ P8 Air Conditioners Technical Data Individual branch selector for VRV heat recovery (Individual BS box) EEDEN11-200 BSVQ100-250P8 Air Conditioners Technical Data Individual branch selector for VRV heat recovery

More information

technical data air conditioning systems MXS-B Multi Application Split Sky Air

technical data air conditioning systems MXS-B Multi Application Split Sky Air technical data MXS-B Multi Application air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment

More information

technical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air technical data RKS-C RKS-B Pair Application, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help

More information

Air Conditioning Technical Data RZQG-L(8)Y1

Air Conditioning Technical Data RZQG-L(8)Y1 Air Conditioning Technical Data RZQG-L(8)Y TABLE OF CONTENTS RZQG-L(8)Y Features............................................................. 2 2 Specifications.......................................................

More information

technical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air

technical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air technical data MA-GZ7 Multi Model Application air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect human health

More information

Split-Sky Air RP-B7 Twin/Triple/Double Twin Application

Split-Sky Air RP-B7 Twin/Triple/Double Twin Application TECHNICAL DATA Split-Sky Air RP-B7 Twin/Triple/Double Twin Application Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment

More information

Air Conditioning. Technical Data EEDEN RXZ-N

Air Conditioning. Technical Data EEDEN RXZ-N Air Conditioning Technical Data EEDEN14-100 RXZ-N TABLE OF CONTENTS RXZ-N 1 Features............................................................. 2 2 Specifications.......................................................

More information

PRK PREVIEW. System. OZONE FRIENDLY R-407C Series. Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump)

PRK PREVIEW. System. OZONE FRIENDLY R-407C Series. Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump) PRK 00-04 PREVIEW System OZONE FRIENDLY R-407C Series Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump) 3DUW#4 2XWGRRU#8QLWV 111111111111111111111111111111111111111111111111111111111111111111111

More information

technical data air conditioning systems 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B

technical data air conditioning systems 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B technical data 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B air conditioning systems technical data 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B air conditioning systems Indoor Units

More information

1 Features. Outdoor Units R-410A RZQ71-140C7V1B. Split Sky Air Outdoor Units

1 Features. Outdoor Units R-410A RZQ71-140C7V1B. Split Sky Air Outdoor Units i r -t i l t - Outdoor Units R-40A RZQ7-40C7VB Features V 7n y CU k 0 S 4 oa o 0 d 7 4Q puz RO S Outdoor units for pair, twin, triple, double twin application The Sky Air Inverter is developed for use

More information

Technical Service Manual

Technical Service Manual Technical Service Manual 60 Hz Low/Mid Pressure Duct Units 7 48 MBH Units 96 MBH Unit June 2009 VRF-SVM21A-EN Low and Mid Pressure Duct Units 1. Features......... 2 2. Specifications......... 3 3. Dimensions.........

More information

Ventilation. Technical Data. Heat reclaim ventilation, humidification and air processing EEDEN VKM-GBM

Ventilation. Technical Data. Heat reclaim ventilation, humidification and air processing EEDEN VKM-GBM Ventilation Technical Data Heat reclaim ventilation, humidification and air processing EEDEN14-205 VKM-GBM Indoor Unit VKM-GBM TABLE OF CONTENTS VKM-GBM 1 Features.............................................................

More information

Air Conditioning. Technical Data. Slim concealed ceiling unit EEDEN FXDQ-A

Air Conditioning. Technical Data. Slim concealed ceiling unit EEDEN FXDQ-A Air Conditioning Technical Data Slim concealed ceiling unit EEDEN14-204 FXDQ-A TABLE OF CONTENTS FXDQ-A 1 Features............................................................. 2 2 Specifications.......................................................

More information

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 2015 1. Features...2 2. Specifications...3 3. Dimensions...7 4.Service Spaces...8 5.Piping

More information

Air Conditioning Technical Data RZQSG-L3/9V1

Air Conditioning Technical Data RZQSG-L3/9V1 Air Conditioning Technical Data RZQSG-L/9V1 Outdoor Unit RZQSG-L/9V1 TABLE OF CONTENTS RZQSG-L/9V1 1 Features............................................................. 2 2 Specifications.......................................................

More information

Split-Sky Air FDYP-B7 Concealed Ceiling Unit

Split-Sky Air FDYP-B7 Concealed Ceiling Unit TECHNICAL DATA Split-Sky Air FDYP-B7 Concealed Ceiling Unit Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the

More information

Low Static Pressure Duct(V shape evaporator)

Low Static Pressure Duct(V shape evaporator) Low Static Pressure Duct (V shape evaporator) 1. Features... 116 2. Specifications... 118 3. Dimensions... 121 4. Service Spaces... 123 5. Piping Diagrams... 124 7.Fan Performance... 126 8.Capacity Tables...

More information

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CV3

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CV3 Heating Technical Data Daikin Altherma low temperature split EEDEN2-725 ERLQ-CV Daikin Altherma low temperature split ERLQ-CV TABLE OF CONTENTS ERLQ-CV Features.............................................................

More information

Air Conditioning. Technical Data EEDEN RXZ-N

Air Conditioning. Technical Data EEDEN RXZ-N Air Conditioning Technical Data EEDEN15-100 RXZ-N Outdoor Unit RXZ-N TABLE OF CONTENTS RXZ-N 1 Features............................................................. 2 2 Specifications.......................................................

More information

Compact Four-way Cassette Type

Compact Four-way Cassette Type 1. Features... 34 2. Specifications... 35 3. Dimensions... 37 4. Service Spaces... 38 5. Piping Diagrams (EXV beside)... 39 6. Wiring Diagrams... 40 7. Capacity Tables... 41 8. Electrical Characteristics...

More information

Fan Coil Units. Technical Data

Fan Coil Units. Technical Data Fan Coil Units Technical Data F a n c o i l u n i t s E E D E N 1 1-4 0 0 Fan Coil Units Technical Data F a n c o i l u n i t s E E D E N 1 1-4 0 0 Table of Contents Table of Contents 3 Round Flow Cassette...

More information

EEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air

EEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air EEDEN08-00 technical data FDQ-B8V3B9 air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led

More information

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4

More information

Job Name: Tag# 3 Port, 2-Ton Outdoor Heat Pump

Job Name: Tag# 3 Port, 2-Ton Outdoor Heat Pump Job Name: Tag# Submittal Data Sheet 3 Port, 2-Ton Outdoor Heat Pump 3MXS24RMVJU Efficiency SEER EER HSPF COP Non-Ducted 18 12.7 12.5 3.53 Ducted 14 9.7 8.2 3.44 Mixed 15.95 11.2 10.35 3.49 Performance

More information

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered

More information

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams... MCAC-VTSM-2013-08 1. Features... 264 2. Specifications... 265 3. Dimensions... 268 4. Service Spaces... 272 5. Piping Diagrams... 273 6. Wiring Diagrams... 274 7. Capacity Tables... 276 8. Electrical Characteristics...

More information

Low Static Pressure Duct (V shape evaporator)

Low Static Pressure Duct (V shape evaporator) MCAC-VTSM-2015-04 Low Static Pressure Duct Type Low Static Pressure Duct (V shape evaporator) 1. Features... 100 2. Specifications... 101 3. Dimensions... 105 4.Service Spaces... 106 5.Piping Diagrams...

More information

Four-way Cassette Type

Four-way Cassette Type Four-way Cassette Type Four-way Cassette Type 1. Features... 9 2. Specifications... 12 3. Dimensions... 17 4. Service Space... 18 5. Wiring Diagrams... 19 6. Capacity Tables... 21 7. Electric Characteristics...

More information

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1

More information

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series VRF Indoor Unit 50Hz Type: Wall Mounted M Series Wall Mounted S Series Contents 01 Wall Mounted M Series 20 Wall Mounted S Series MCAC-VTSM-2016-05 Wall Mounted M Series Wall Mounted M Series 1. Features...

More information

Split. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B

Split. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B Split Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B Indoor Unit FTXC-A TABLE OF CONTENTS FTXC-A 1 Features.............................................................

More information

Split-Sky Air FAYP-B Wall Mounted Unit

Split-Sky Air FAYP-B Wall Mounted Unit TECHNICAL DATA Split-Sky Air FAYP-B Wall Mounted Unit Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential

More information

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...

More information

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( ) 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation

More information

Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2

Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2 2-8 GENERAL DATA 2.3. INVERTER SERIES 2.3.1. INVERTER (RAS-25YHA2/35YHA3/50YHA2/60YHA2/70YHA2/80YHA2) Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2 Power Supply From Outdoor Unit

More information

Air Conditioning. Technical Data EEDEN RXJ-L

Air Conditioning. Technical Data EEDEN RXJ-L ir Conditioning Technical Data EEDEN5-0 RXJ-L Outdoor Unit RXJ-L TLE OF CONTENTS RXJ-L Features............................................................. Specifications.......................................................

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r u n i t E E D E N 2-0 0 RXG-K Outdoor Unit Pair application RXG-K TABLE OF CONTENTS RXG-K Features.............................................................

More information

Service manual MIV V4+ Indoor units

Service manual MIV V4+ Indoor units Service manual MIV V4+ Indoor units Floor Standing MVF22A-VA1 MVF28A-VA1 MVF36A-VA1 MV5A-VA1 MVF56A-VA1 MVF71A-VA1 MVF80A-VA1 MVB22A-VA1 MVB28A-VA1 MVB36A-VA1 MVB45A-VA1 MVB56A-VA1 MVB71A-VA1 MVB80A-VA1

More information

technical data Systems FXMQ-MVE Conceiled ceiling unit (large)

technical data Systems FXMQ-MVE Conceiled ceiling unit (large) technical data Systems FXMQ-MVE Conceiled ceiling unit (large) FXMQ-MVE 11 Concealed ceiling unit (large) 11 1 Features...2 2 Specifications Technical specifications...3 Electrical specifications...4 Safety

More information

PCXAU1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A

PCXAU1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A PCXAU161 VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ Heat Pump 5/6 Hz R-1A An industry first, the VRV air handling unit has been designed and engineered

More information

VRF Technical Data Book

VRF Technical Data Book VRF Technical Data Book DVM S Eco for America (R410A, 60Hz, HR) Model : AM***NXMDCR/AA History Version Modification Date Remark Ver.1.0 Released DVM S Eco HR for North America TDB 18.02.28 Ver.1. Re 18.0

More information

Air Conditioners. Technical Data UATYQ-CY1

Air Conditioners. Technical Data UATYQ-CY1 Air Conditioners Technical Data R o o f t o p s E E D E N 2-2 0 UATYQ-CY Air Conditioners Technical Data R o o f t o p s E E D E N 2-2 0 UATYQ-CY Single Unit Rooftop UATYQ-CY TABLE OF CONTENTS UATYQ-CY

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

HCH6. Product Specifications

HCH6. Product Specifications HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland

More information

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features

More information

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE TECHNICAL SELECTION DATA SPLIT DUCTED UNIT 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE AXIAL UNIT FEATURES Scroll Compressor Multiple Speed Outdoor Fans Louvred Outdoor Coil Guard Pre-charged with

More information

ROOF TOP PACKAGE UNITS

ROOF TOP PACKAGE UNITS ROOF TOP PACKAGE UNITS HIEER : 3-25 Tons PRODUCT DATA BOOK Introduction Roof Top Package units have been developed & produced to provide not only the ultimate indoor comfort, but also to guarantee long

More information

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit

More information

EDAU RWEYQ-PY1. Water Cooled Inverter Series Heat Pump 50Hz Heat Recovery 50Hz

EDAU RWEYQ-PY1. Water Cooled Inverter Series Heat Pump 50Hz Heat Recovery 50Hz RWEYQ-PY1 Water Cooled Inverter Series Heat Pump 50Hz Heat Recovery 50Hz Introduction...... ii Part 1 General Information...... 1 Part 2 Outside unit... RWEYQ-P... 11 Part 3 Interlock operation......

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2012.10 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics

More information

RAC. Technical Data Book. RAC for North America (Inv, R410A, 60Hz, HP)

RAC. Technical Data Book. RAC for North America (Inv, R410A, 60Hz, HP) RAC Technical Data Book RAC for North America (Inv, R410A, 60Hz, HP) Model : AR09/12JSALBWKNCV AR09/12JSALBWKXCV AR09/12/18/24JSFLBWKNCV AR09/12/18/24JSFLBWKXCV History Version Modification Date Remark

More information

RCD Air Cooled Condensing Unit (50/60 Hz)

RCD Air Cooled Condensing Unit (50/60 Hz) Environment friendly Easy to access components More efficient air cooled condenser coils Easy to install and maintain The Saudi Factory for Air Conditioning Units RCD Air Cooled Condensing Unit (50/60

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at

More information

SINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU

SINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU SINGLE Technical Data Book Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU History Version Modification Date Remark Ver.1.0 Release SINGLE Big

More information

Concealed Ducted Split Series R22

Concealed Ducted Split Series R22 Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING

More information

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07. Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water

More information

SINGLE. Technical Data Book. Big Ceiling for Europe (R410A, 50Hz, H/P)

SINGLE. Technical Data Book. Big Ceiling for Europe (R410A, 50Hz, H/P) SINGLE Technical Data Book Big Ceiling for Europe (R4A, Hz, H/P) Version Modification Date Remark Ver.1. Release SINGLE Big Ceiling for Europe (R4A, Hz, H/P) TDB 1.4.3 Ver.1.1 Modification for drain pipe

More information

PCXDMT1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A

PCXDMT1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A PCXDMT1601 VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ Heat Pump 50/60 Hz R-10A Airport Lobby Hospital Factory Shopping Mall Sports Hall Showroom Warehouse

More information

DVM. Technical Data Book

DVM. Technical Data Book DVM Technical Data Book Outdoor Units I. Products 1 2 3 Outdoor units Indoor units Accessories 6 7 9 2 II. Outdoor units 1 2 3 4 5 6 Specifications Operation limit Electrical wiring diagram Sound level

More information

MODEL: DCT 35 INV-Si DCT 50 INV-Si DCT 70 INV-Si DCT 100 INV-Si DCT 140 INV-Si DCT 170 INV-Si

MODEL: DCT 35 INV-Si DCT 50 INV-Si DCT 70 INV-Si DCT 100 INV-Si DCT 140 INV-Si DCT 170 INV-Si MODEL: DCT 35 INV-Si DCT 50 INV-Si DCT 70 INV-Si DCT 100 INV-Si DCT 140 INV-Si DCT 170 INV-Si Part 1 General Information.. 1 Part 2 Indoor Units. Part 3 Outdoor Units. Part 5 Control... Part 6 Control

More information

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-GV

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-GV Air Conditioning Technical Data Wall mounted unit EEDEN15-100 FTX-GV TABLE OF CONTENTS FTX-GV 1 Features............................................................. 2 2 Specifications.......................................................

More information

UMXCA/UMXCBA ECVA/ECVBA

UMXCA/UMXCBA ECVA/ECVBA OUTDOOR UNITS Models: 801.1 1001.1 1201.1 1501.1 1602.2 2002.2 2402.2 3002.2 3502.2 4002.2 4502.2 Cooling Capacities: from 25,9 kw to 134,7 kw Heating Capacities: from 27,3 kw to 142,4 kw INDOOR UNITS

More information

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker HVA9 Product Specifications HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal

More information

Manufacturer reserves the right to change these specifications at any time without incurring obligation. Btuh (kw) SEER SHR EER

Manufacturer reserves the right to change these specifications at any time without incurring obligation. Btuh (kw) SEER SHR EER UNHA-T2CA-T3CA-T4CA Universal Air Handler Multi-Zone Only Rev. 1.0 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: UNIT

More information

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit RD-90EB RO-90EPB C O N T E N T S SPECIFICATIONS... OUTLINE AND DIMENSIONS... CIRCUIT DIAGRAM...5 REFRIGERANT SYSTEM DIAGRAM...6

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

SINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU)

SINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU) SINGLE Technical Data Book 4Way Cassette S for Nordic (R4A, 5Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU) History Version Modification Date Remark Ver.1. Released SINGLE for Nordic TDB 15.3.. Ver.1.1

More information

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners CPC Commercial Cooling Capacity: 90,000 118,000 BTU/h 7½- to 12½-Ton Three-Phase Packaged Air Conditioners up to 11.5 EER Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor

More information

DC INVERTER DUCTED AIR CONDITIONERS

DC INVERTER DUCTED AIR CONDITIONERS DC INVERTER DUCTED AIR CONDITIONERS DC Inverter Ducted Air Conditioners Technology. With over 5% of revenue invested in research and development programs, Hitachi has developed world leading technologies

More information

Superior Performance in Extreme Temperature Submittal Data: SAP09HP230V1A

Superior Performance in Extreme Temperature Submittal Data: SAP09HP230V1A Superior Performance in Extreme Temperature Submittal Data: 9,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXS-K

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXS-K Air Conditioning Technical Data Wall mounted unit EEDEN3-00 FTXS-K Indoor Unit Wall mounted unit FTXS-K TABLE OF CONTENTS FTXS-K Features............................................................. 2

More information

WCA4**4. Product Specifications

WCA4**4. Product Specifications WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASYA24LCC ASYA24LCC ASYA24LCC Outdoor unit AOYR24LCC AOYR24LCD AOYR24LCL CONTENTS SPECIFICATIONS..................1 DIMENSIONS.....................

More information

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CU060-300 5-25 TONS VERTICAL SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CH060-5-10 TONS HORIZONTAL FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TABLE OF CONTENTS

More information

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz 3 PHASE HEAT PUMP COMPONENT 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain proper charge of mineral oil Suction line accumulator

More information

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h Energy-Efficient Split System Heat Pump 1½ to 5 Tons Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling

More information

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz] R22 TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E Cooling only & Heatpump [50Hz] Table of Contents Table of Contents Nomenclature...1 Indoor...1

More information

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75. Chiller AQL/ to 75 Air Cooled Water Chillers Only and Heat Pump Engineering Data Manual.0 to 75.8 kw 39.9 to 77.2 kw Outstanding Strength Points R410A Refrigerant. New simpler refrigerant circuit layout.

More information

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Indoor Console Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Black Display Functional art, the touch screen display is elegant

More information