1 SINGLE Technical Data Book Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU
2 History Version Modification Date Remark Ver.1.0 Release SINGLE Big Duct for Europe (R410A, 50Hz, H/P) TDB Ver.1.1 Delete Energy Grade Ver.1.2 Ver.1.3 Ver.1.4 Ver.1.5 Modified the cycle diagram (20kW model) Add Note information in Specification regarding EU F-Gas regulation. Modification for Specification (MCA, MFA) Modification for Sound Power Level data and graphs (p.6, p.11). AC180JNHPKH/EU (ODU: AC180JXAPNH/EU) : db(a). AC200JNHPKH/EU (ODU: AC200JXAPNH/EU) : db(a)
3 Index 1 Nomenclature 2 Specifications (Indoor) 3 Capacity table 4 Dimensional drawing (Indoor) 5 Electrical wiring diagram (Indoor) 6 Sound pressure level (Indoor) 7 Sound power level (Indoor) 8 Recommended operation range (Indoor) 9 Electrical wiring diagram () 10 Sound pressure level () 11 Sound power level () 12 Cycle diagram () 13 Dimensional drawing () 14 Capacity correction ()
4 1 Nomenclature Indoor Units Model Names AC 10 J N H K H (1) (2) (3) (4) (5) (6) (7) (8) Buyer (1) Classification AC AM SINGLE VRF (5) Product Notation 1 1Way Cassette 2 2Way Cassette N 4Way Cassette S (600 x 600) 4 4Way Cassette S (2) Capacity x 1/10 kw (3 digits) L M H LSP Duct (Slim Duct) MSP Duct HSP Duct C Ceiling (3) Version F 2013 H 2014 J 2015 T E (6) Feature D Neo Forte OAP Duct DELUXE F FLAGSHIP (4) Product Type N Indoor Unit P G(EHS) Premium Cascade (EEV) X Unit (7) Rating Voltage C 1Ø, 208~230V, 60Hz E G K N 1Ø, 220~240V, 50Hz 3Ø, 380~415V, 50Hz 1Ø, 220~240V, 50/60Hz 3Ø, 380~415V, 50/60Hz (8) Mode C H D E Cooling Only(R410A) Heat Pump(R410A) Cooling Only(R22) Heat Pump(R22)
5 1 Nomenclature Units Model Names AC 1 0 J X A H (1) (2) (3) (4) (5) (6) (7) (8) Buyer (1) Classification (5) Feature1 AC SINGLE A Inv+Side+General Temp AM VRF B Non Inv+Side+General Temp (2) Capacity (6) Feature2 x 1/10 kw (3 digits) D Deluxe F Flagship P Premium (3) Version E 2012 S Standard F 2013 H 2014 J 2015 (7) Rating Voltage E 1Ø, 220~240V, 50Hz G 3Ø, 380~415V, 50Hz K 1Ø, 220~240V, 50/60Hz (4) Product Type N 3Ø, 380~415V, 50/60Hz N Indoor Unit X Unit (8) Mode C Cooling Only(R410A) H Heat Pump(R410A) D Cooling Only(R22) E Heat Pump(R22)
6 2 Specifications HSP Duct Type HSP Duct HSP Duct Model Name Indoor Unit AC180JNHPKH/EU AC200JNHPKH/EU Unit AC180JXAPNH/EU AC200JXAPNH/EU Mode - Heat Pump Heat Pump Capacity Cooling(Min/Std/Max) kw 6.00 / / / / Btu/h 20,500 / 61,400 / 68,200 21,200 / 68,200 / 76,800 Heating(Min/Std/Max) kw 4.80 / / / / Btu/h 16,400 / 68,200 / 76,800 17,100 / 75,100 / 85,300 Power Cooling(Min/Std/Max) 1.30 / 5.45 / / 6.23 / Input kw (Nominal) Heating(Min/Std/Max) 1.20 / 5.54 / / 6.09 / Power Current Cooling(Min/Std/Max) 2.30 / 8.40 / / / Input A (Nominal) Heating(Min/Std/Max) 2.20 / 8.60 / / / MCA A (MCA) (MCA) MFA A EER (Nominal Cooling) System Energy COP (Nominal Heating) Efficiency - Energy Grade - Liquid Pipe Ø, mm Ø, inch 3/8" 3/8" Piping Ø, mm Connections Gas Pipe Ø, inch 3/4" 3/4" Installation Max. Length m Limitation Max. Height m (0 )* Power Source Wire Ø, mm Field Wiring Transmission Cable Ø, mm Type - R410A R410A Refrigerant Control Method - Factory Charging kg Power Supply Ø, #, V, Hz 1,2, ,50 1,2, ,50 Type - Sirocco Fan Sirocco Fan Motor Output W Fan Air Flow Rate High/Mid/Low CMM / / / / l/s 1, / 1, / , / 1, / External Static mmaq 5.00 / 6.12 / / 7.34 / Pressure Min/Std/Max Pa / / / / Drain Drain Pipe Ø,mm VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) Sound Pressure High/Mid/Low 43 / 39 / / 40 / 36 db(a) Power Cooling Indoor Unit Net Weight kg External Shipping Weight kg Dimension (WxHxD) Net Dimensions mm 1,350 x 910 x 450 1,350 x 910 x 450 Shipping Dimensions (WxHxD) mm 1,612 x 519 x 984 1,612 x 519 x 984 Panel model - Panel Net Weight kg Panel Size Shipping Weight kg Net Dimensions (WxHxD) mm Shipping Dimensions (WxHxD) mm Drain External - MDP-G075SP MDP-G075SP Additional pump Accessories Internal - MDP-G075SQ MDP-G075SQ Air Filter - Power Supply Ø, #, V, Hz 3,4, ,50 3,4, ,50 Type - Twin BLDC Rotary BLDC Scroll Model - UG5T520FUBJX DS-GB052FAVA Compressor Output kw Oil Type - Fan Air Flow CMM Rate Cooling l/s 1, , Unit Pressure Cooling/Heating 55 / / 59 Sound db(a) Power Cooling Net Weight kg External Shipping Weight kg Dimension Net Dimensions (WxHxD) mm 940 x 1,420 x x 1,695 x 765 Shipping Dimensions (WxHxD) mm 995 x 1,598 x x 1,887 x 832 Operating Cooling ºC ~ ~ 50.0 Temp. Range Heating ºC ~ ~ All figures comply with EN Nominal cooling capacities are based on; Indoor temperature : 27 C DB, 19 C WB / temperature : 35 C DB, Refrigerant piping : 5m(18kW) / 7.5m(20kW), Level differences : 0m - Nominal heating capacities are based on; Indoor temperature : 20 C DB, 15 C WB / temperature : 7 C DB, 6 C WB, Refrigerant piping : 5m(18kW) / 7.5m(20kW), Level differences : 0m - Sound level was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions. - Specifications may be subject to change without prior notice. - These products contain R410A which is fluorinated greenhouse gas. - If indoor unit is located in a higher position than outdoor unit, please refer to the ( )* value of Installation Height Limitation.
7 3 Capacity table HSP Duct AC180JNHPKH/EU + AC180JXAPNH/EU Cooling temperature (ºC, DB) Indoor temperature (ºC, WB) TC(Total Capacity), SHC(Sensible Heat Capacity), PI(Power Input) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw Heating TC : Total Capacity, PI: Power Input temperature (ºC, DB) Indoor temperature (ºC, DB) TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw AC200JNHPKH/EU + AC200JXAPNH/EU Cooling TC(Total Capacity), SHC(Sensible Heat Capacity), PI(Power Input) Indoor temperature (ºC, WB) temperature (ºC, DB) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw Heating TC : Total Capacity PI: Power Input Indoor temperature (ºC, DB) temperature (ºC, DB) TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw Capacities are based on following conditions;. Cooling mode indoor air temperature ( C, DB/WB) : 22/16, 27/19, 30/22. Heating mode outdoor air : 85%RH. However, the condition rated capacity is 7 C DB / 6 C WB.. Refrigerant piping length : 5m(18kW) / 7.5m(20kW). Level difference : 0m.
8 4 Dimensional drawing HSP Duct AC180JNHPKH/EU, AC200JNHPKH/EU Units : mm / inches 1439 [4'-8 3/4"] 1392(Suspension position) [4'-6 3/4"] 1350 [4'-5 1/4"] 850 [2'-9 1/2"] 782(Suspension position) [2'-6 3/4"] 450 [1'-5 3/4"] 360 [1'-2 1/4"] 300(6x50) [11 3/4"] 1200(24x50) [3'-11 1/4"] 1284(Air outlet duct flange) [4'-2 1/2"] 220 [8 3/4"] 279 [11"] 910 [2'-11 3/4"] Inspection hole 450 [1'-5 3/4"] Service area 500 [1'-7 3/4"] 1350 [4'-5 1/4"] 1450 [4'-9"] 30 [1 1/4"] Table of descriptions 1 Liquid pipe connection 7 2 Gas pipe connection 8 3 Drain pipe connection 9 4 Power supply connection 10 5 Air discharge flange 11 6 Hook 12
9 5 Electrical wiring diagram HSP Duct AC180JNHPKH/EU, AC200JNHPKH/EU
10 6 Sound pressure level HSP Duct Unit: db(a) Model High Low AC180JNHPKH/EU (ODU : AC180JXAPNH/EU) AC200JNHPKH/EU (ODU : AC200JXAPNH/EU) Note - These operation values were obtained in an anechoic room. - Sound pressure level will vary depending on a range of the factors such as the construction of the particular room where the equipment is installed. NC curve 1) AC180JNHPKH/EU (ODU : AC180JXAPNH/EU) 2) AC200JNHPKH/EU (ODU : AC200JXAPNH/EU)
11 7 Sound Power Level HSP Duct Note dba = A-weighted sound power level. Reference power : 1pW. Measured according to ISO Unit: db(a) Model Power AC180JNHPKH/EU (ODU : AC180JXAPNH/EU) 69 AC200JNHPKH/EU (ODU : AC200JXAPNH/EU) 70 1) AC180JNHPKH/EU (ODU : AC180JXAPNH/EU) 2) AC200JNHPKH/EU (ODU : AC200JXAPNH/EU) Sound Power Level(dB) Sound Power Level(dB) A Octave Band Center Frequency(Hz) A Octave Band Center Frequency(Hz)
12 8 Recommended operation range HSP Duct 1) AC180JNHPKH/EU (ODU : AC180JXAPNH/EU) 2) AC200JNHPKH/EU (ODU : AC200JXAPNH/EU) External Static Pressure (mmaq) Option Code 01107C-1C50B0-27B C-1C50E3-27B C-1C50F5-27B C-1C B C-1C B C-1C548E-27B External Static Pressure (mmaq) Option Code C50C0-20C8DC C50E3-20C8DC C50F5-20C8DC C C8DC C C8DC C548E-20C8DC Note - Adjust option code according to the actual installation condition (external static pressure). - The graphs display the available external static pressure range of installed indoor units. Therefore, they do not reflect the actual change of external static pressure and airflow rate according to adjusted airflow (High-Mid-Low) of installed indoor units.
13 9 Electrical wiring diagram AC180JXAPNH/EU
14 9 Electrical wiring diagram AC200JXAPNH/EU
15 10 Sound pressure level Unit: db(a) Model Cooling Heating AC180JXAPNH/EU (IDU : AC180JNHPKH/EU) Note - These operation values were obtained in an anechoic room.(conversion value) - Operation sound level may differ depending on operation and ambient conditions. NC curve 1) AC180JXAPNH/EU (IDU : AC180JNHPKH/EU)
16 10 Sound pressure level Unit: db(a) Model Cooling Heating AC200JXAPNH/EU (IDU : AC200JNHPKH/EU) Note - These operation values were obtained in an anechoic room.(conversion value) - Operation sound level may differ depending on operation and ambient conditions. NC curve 2) AC200JXAPNH/EU (IDU : AC200JNHPKH/EU)
17 11 Sound power level Note dba = A-weighted sound power level. Reference power : 1pW. Measured according to ISO Unit: db(a) Model Power AC180JXAPNH/EU (IDU : AC180JNHPKH/EU) 76.0 AC200JXAPNH/EU (IDU : AC200JNHPKH/EU) ) AC180JXAPNH/EU (IDU : AC180JNHPKH/EU) 2) AC200JXAPNH/EU (IDU : AC200JNHPKH/EU)
18 12 Cycle diagram AC180JXAPNH/EU Unit Heat Exchanger Indoor Unit 4Way Valve EEV Filter Muffler Compressor Ac Category Description Compressor Rotary Inverter Compressor Heat Exchanger Condensing/Evaporating unit(fmc) AC Accumulator Filter Filter Valve Sensor Expansion Reversing Service Temperature Electronic Expansion Valve(EEV) 4 Way valve (Reversing valve) Service valve Pipe/Air Temperature sensor
19 12 Cycle diagram AC200JXAPNH/EU Unit Indoor Unit E_ID Category Description Category Description E_ID Indoor EEV
20 13 Dimensional drawing AC180JXAPNH/EU
21 13 Dimensional drawing AC200JXAPNH/EU
22 14 Capacity correction AC180JNHPKH/EU + AC180JXAPNH/EU Cooling Level Difference (m) Pipe Length (m) Heating Level Difference (m) Pipe Length (m) AC200JNHPKH/EU + AC200JXAPNH/EU Cooling Level Difference (m) Pipe Length (m) Heating Level Difference (m) Pipe Length (m)
23 Ver. 1.5 Samsung Electronics Co., LTD. B2B PM / SE Head Office (Suwon Korea) 129, Samsung-Ro, Yeongtong-Gu, Suwon City, Gyeonggi-Do, Korea Website : airconditioner@samsung.com Images and data in this book may subject to change without prior notice.
SINGLE. Technical Data Book. Big Ceiling for Europe (R410A, 50Hz, H/P)
SINGLE Technical Data Book Big Ceiling for Europe (R4A, Hz, H/P) Version Modification Date Remark Ver.1. Release SINGLE Big Ceiling for Europe (R4A, Hz, H/P) TDB 1.4.3 Ver.1.1 Modification for drain pipe
More informationSINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU)
SINGLE Technical Data Book 4Way Cassette S for Nordic (R4A, 5Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU) History Version Modification Date Remark Ver.1. Released SINGLE for Nordic TDB 15.3.. Ver.1.1
More informationVRF. Technical Data Book. Duct S for Europe (R410, 50Hz)
VRF Technical Data Book Duct S for Europe (R410, 50Hz) Version Modification Date Remark Ver.1.0 Release VRF DVM S IDU Duct S for Europe (R410A, 50Hz) TDB 14.09.22 Ver.1.1 External Pressure Minimum data
More informationSINGLE. Technical Data Book. HSP Duct for America (R410A, 60Hz, H/P)
SINGLE Technical Data Book HSP Duct for America (R41A, 6Hz, H/P) Version Modification Date Remark Ver.1.4 Modified MCA 16.3.8 Ver.1.5 Modified Specifcation for MCA, Compressor oil type, Capacity Table,
More informationVRF. Technical Data Book. DVM Indoor Unit PAC for Global (INV, R410A, HP) Model : AM140JNPDKH/TK (50/60Hz) AM280JNPDKH/TK (50Hz)
VRF Technical Data Book DVM Indoor Unit PAC for Global (INV, R410A, HP) Model : AM140JNPDKH/TK (50/60Hz) AM280JNPDKH/TK (50Hz) History Version Modification Date Remark Ver.1.0 Release DVM Indoor PAC for
More informationRAC. Technical Data Book. RAC for North America (Inv, R410A, 60Hz, HP)
RAC Technical Data Book RAC for North America (Inv, R410A, 60Hz, HP) Model : AR09/12JSALBWKNCV AR09/12JSALBWKXCV AR09/12/18/24JSFLBWKNCV AR09/12/18/24JSFLBWKXCV History Version Modification Date Remark
More informationVRF. Technical Data Book. Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH***
VRF Technical Data Book Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH*** History Version Modification Date Remark Ver.1.0 Release Ceiling for America (R410A, 60Hz, HP) 15.11.04 - 1 Nomenclature
More informationSINGLE. Technical Data Book. PAC for Europe (R410A, 50Hz, HP) Model : AC***KNPDEH/EU AC***KXAD*H/EU
SINGLE Technical Data Book PAC for Europe (R410A, 50Hz, HP) Model : AC***KNPDEH/EU AC***KXAD*H/EU History Version Modification Date Remark Ver 1.0 Release SINGLE PAC for Europe (R410A, 50Hz) 16.07.15 -
More informationVersion Modification Date Remark
Version Modification Date Remark Index 1 Nomenclature 2 Specifications 3 Capacity table 4 Dimensional drawing 5 Electrical wiring diagram 6 Sound pressure level 7 Temperature and air flow distribution
More informationERV. Technical Data Book. ERV for Europe (NASA, 50Hz, 60Hz)
Technical Data Book for Europe (NASA, Hz, Hz) History Version Modification Date Remark Ver.1. Released TDB 15.5.11 Ver.1.1 Add Note information in Specification regarding EU F-Gas regulation 15.6.16 Index
More informationDVM. Technical Data Book
DVM Technical Data Book Outdoor Units I. Products 1 2 3 Outdoor units Indoor units Accessories 6 7 9 2 II. Outdoor units 1 2 3 4 5 6 Specifications Operation limit Electrical wiring diagram Sound level
More informationIndoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.
Indoor Console Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Black Display Functional art, the touch screen display is elegant
More informationVRF. Technical Data Book. DVM IDU_Vertical AHU for NA (R410A, 60Hz, HP) Model : AM***JNZDCH/AA
VRF Technical Data Book DVM IDU_ for NA (R4A, 6Hz, HP) Model : AM***JNZDCH/AA Version Modification Date Remark Ver.. Release DVM Indoor Unit_ TDB for America 5. 6.. Ver.. Modification for Heater kit (option)
More informationMSP Duct S Specifications
MSP Duct S Specifications Model Name AM022FNMDEH AM028FNMDEH AM036HNMPKH AM045HNMPKH AM056HNMPKH Capacity *2) 2.2 2.8 3.6 4.5 5.6 *3) 2.5 3.2 4.0 5.0 6.3 Perfomance (Total) *5) kw 1.8 2.3 2.9 3.7 4.6 VRF
More informationVersion Modification Date Remark
Version Modification Date Remark Products 1 Nomenclature... 2 Line-up... 3 Accessory... 1 Nomenclature 1-1. Nomenclature Model name AM RVX 45 1 HF TN T4 FD EE EH / EU 1 (Buyer) Classification AM DVM
More informationVRF Technical Data Book
VRF Technical Data Book DVM S Eco for America (R410A, 60Hz, HR) Model : AM***NXMDCR/AA History Version Modification Date Remark Ver.1.0 Released DVM S Eco HR for North America TDB 18.02.28 Ver.1. Re 18.0
More informationPERFECTLY EVEN COOLING CIRCULAR DESIGN 360 CASSETTE. The World s First Circular Cassette. Circular LED Display Window. 360 Air Flow Blade-less
Air Conditioning Solutions 2016 360 CASSETTE CIRCULAR DESIGN Its full-circle design allows it to be placed beautifully in any setting. PERFECTLY EVEN COOLING Innovative 360 degree airflow ensures optimal
More informationSINGLE Technical Data Book. SINGLE for Europe (R410A, HP)
SINGLE Technical Data Book SINGLE for Europe (R410A, HP) History Ver.1.0 Release Single TDB for Europe 16. 11. 02 Ver.1.1 Add tco2e data (Specifications) 16. 12. 09 Ver.1. 1.. 09 2 CAC - World-class energy
More informationCeiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary
Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature
More informationVRF Technical Data Book
VRF Technical Data Book Duct S for North America (R1A, Hz) Model : AM7~18MNMDCH/AA AM2~8MNHDCH/AA History Version Modification Date Remark Ver.1. Release Duct S TDB for North America 17.. 21. 2 Nomenclature
More informationSUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP
VEP075N432K Job Name: Location: Schedule No.: System Designation: Engineer: Architect: Date: For: Reference Approval Review Construction FEATURES Two-pipe heat pump Hinged electrical box for ease of maintenance
More informationR410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2
R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1
More informationSUBMITTAL DATA: MXZ-3C30NA2 MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM
M-SERIES SUBMITTAL DATA: MXZ-3C30NA2 MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM Job Name: System Reference: Date: Outdoor Unit: MXZ-3C30NA2 ACCESSORIES 3/8" x 1/2" Port Adapter (MAC-A454JP-E) 1/2" x 3/8" Port
More informationM1 TYPE SLIM VARIABLE STATIC PRESSURE HIDE AWAY CONCEALED DUCT
VRF SYSTEMS M TYPE SIM VARIABE STATIC PRESSURE IDE AWAY CONCEAED DUCT The ultra slim M type is one of the leading products of its type in the industry. With a depth of only mm it provides greater flexibility
More informationSUBMITTAL DATA: MXZ-2C20NAHZ MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM. Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz
M-SERIES SUBMITTAL DATA: MXZ-2C20NAHZ MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM Job Name: System Reference: Date: Outdoor Unit: MXZ-2C20NAHZ ACCESSORIES 3/8" x 1/2" Port Adapter (MAC-A454JP; for use with
More informationProduct Catalog. Variable Refrigerant Flow (VRF) VRF-PRC026A-EN. Mid-Static Concealed (Ducted) Indoor Units. November 2015
Product Catalog Variable Refrigerant Flow (VRF) Mid-Static Concealed (Ducted) Indoor Units Indoor Unit Model number: 4TVD****C***** November 2015 VRF-PRC026A-EN Introduction Trane variable refrigerant
More informationSUBMITTAL DATA: MXZ-3C30NAHZ2 MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM. Yes Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz
M-SERIES SUBMITTAL DATA: MXZ-3C30NAHZ2 MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM Job Name: System Reference: Date: ACCESSORIES 3/8" x 1/2" Port Adapter (MAC-A454JP-E) 1/2" x 3/8" Port Adapter (MAC-A455JP-E)
More informationOutdoor Units R-410A ARX-GV1B
Outdoor Units R-40A ARX-GVB t A i n y U k BS r o AV t o0g i d- lt4x pur- SRAO 2 Specifications Outdoor Units R-40A ARX-GVB 2- NOMINAL CAPACITY AND NOMINAL INPUT ARX20GVB ARX25GVB ARX5GVB For combination
More informationYCZ HIGH WALL RESIDENTIAL MULTISPLIT DUO/TRIO/QUATTRO/CINCO
YCZ RESIDENTIAL MULTISPLIT DUO/TRIO/QUATTRO/CINCO q Multi line available in four capacities from 5.2 up to 10.5 kw. q DC Inverter and sine wave compressor drive technology. q Match with high wall, ducted,
More information1. Indoor Units 5 2. Outdoor Units 8 3. Accessories 10
Technical Data Book Contents I. Products 1. Indoor Units 5 2. Outdoor Units 8 3. Accessories 10 II. Indoor Units 1. Specifications 12 2. Electrical Wiring Diagram 15 3. Dimensional Drawing 18 4. Sound
More informationtechnical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air
technical data RXG-C Wall Mounted, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human
More informationAir Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB
Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQA3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB TABLE OF CONTENTS FXDQ-A3 1 Features.............................................................
More informationtechnical data air conditioning systems Round Flow Cassette FXFQ-P9VEB
technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems TABLE OF CONTENTS FXFQ-P9VEB 1 Specifications.......................................................
More information40KQV. Direct expansion split system Inverter Cassette. Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw
LLOYD'S REGISTER QUALITY ASSURANCE Direct expansion split system Inverter Cassette I S O 9 00 1 40KQV Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw 40KQV cassette belongs
More informationMulti-Room Ductless heat-pump systems Submittal Data: MULTI56HP230V1AO 56,000 BTUH Super +Multi-port Heat Pump System Job Name Location Date
Multi-Room Ductless heat-pump systems Submittal Data: 56,000 BTUH Super +Multi-port Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Reference Approval Construction Unit Designation
More informationJob Name: Tag# 3 Port, 2-Ton Outdoor Heat Pump
Job Name: Tag# Submittal Data Sheet 3 Port, 2-Ton Outdoor Heat Pump 3MXS24RMVJU Efficiency SEER EER HSPF COP Non-Ducted 18 12.7 12.5 3.53 Ducted 14 9.7 8.2 3.44 Mixed 15.95 11.2 10.35 3.49 Performance
More informationCooling Compressor Type DC Inverter Driven Rotary Rated Capacity 48,000 BTU/H RLA 23.0 A
Submittal Data: Multi-Room Ductless heat-pump systems 48,000 BTUH Super +Multi-port Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationCooling Compressor Type DC Inverter Driven Rotary Rated Capacity 53,000 BTU/H RLA 23.0 A
Submittal Data: Multi-Room Ductless heat-pump systems 56,000 BTUH Super +Multi-port Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationEngineering Data Book
Engineering Data Book Contents Specifications 2 Dimensions of Indoor 3 and outdoor units Indoor unit Outdoor unit Wiring diagrams 6 RAS-05BKV-E RAS-07BKV-E RAS-05BAV-E RAS-07BAV-E Sensible capacity table
More informationSUBMITTAL DATA: MXZ-5C42NAHZ MULTI-INDOOR INVERTER HEAT PUMP SYSTEM. Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz
M-SERIES SUBMITTAL DATA: MXZ-5C42NAHZ MULTI-INDOOR INVERTER HEAT PUMP SYSTEM Job Name: System Reference: Date: Outdoor Unit: MXZ-5C42NAHZ ACCESSORIES Three-port Branch Box (PAC-MKA30BC) Five-port Branch
More informationTechnical Service Manual
Technical Service Manual 60 Hz Low/Mid Pressure Duct Units 7 48 MBH Units 96 MBH Unit June 2009 VRF-SVM21A-EN Low and Mid Pressure Duct Units 1. Features......... 2 2. Specifications......... 3 3. Dimensions.........
More informationR22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]
R22 TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E Cooling only & Heatpump [50Hz] Table of Contents Table of Contents Nomenclature...1 Indoor...1
More informationVersion Modification Date Remark
History Version Modification Date Remark Ver.1.0 Release FJM IDU,ODU for North America (R410A, 60Hz, HP) TDB 15.02.11 - Ver.1.1 Modify for EEV not Incuded, Shipping dimension 16.10.17 - Ver.1.2 Modify
More informationEngineering Data Book
40VMM Medium Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationPACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.
TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor
More informationDC Inverter 10.0 / 12.5 / 14.0 kw
DC Inverter 10.0 / 12.5 / 14.0 kw Outdoor Units GC 36 DCI GC 43 DCI GC 60 DCI Indoor Units DLS 36 DCI DHC 36 DCI DLS 43 DCI DHC 43 DCI CD 60 DCI REFRIGERANT R410A HEAT PUMP NOVEMBER 2008 LIST OF EFFECTIVE
More informationSamsung Modelling Guide for equest
Samsung Modelling Guide for equest Disclaimer The information contained in this equest Modeling Guide and in the DVM S library file (the Information ) is for informational purposes only and should not
More informationMulti-Room Ductless heat-pump systems Submittal Data: MULTI18HP230V1AO 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date
Multi-Room Ductless heat-pump systems Submittal Data: 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. Reference Approval
More informationMulti Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Multi Air Conditioner SVC MANUAL(Exploded View) MDEL : A4UW246FA3 CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual. nly for
More information1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...
MCAC-VTSM-2013-08 1. Features... 264 2. Specifications... 265 3. Dimensions... 268 4. Service Spaces... 272 5. Piping Diagrams... 273 6. Wiring Diagrams... 274 7. Capacity Tables... 276 8. Electrical Characteristics...
More informationFour-way Cassette Type
Four-way Cassette Type Four-way Cassette Type 1. Features... 9 2. Specifications... 12 3. Dimensions... 17 4. Service Space... 18 5. Wiring Diagrams... 19 6. Capacity Tables... 21 7. Electric Characteristics...
More informationEngineering Data Book
40VMH High Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationFDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E
R407C TECHNICAL MANUAL Split Systems Air Conditioner Ducted Blower D & E Series FDMP-D, FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E series Cooling only & Heatpump [50Hz] Table of Contents Table of Contents
More informationDUCTED INDOOR UNIT ENGINEERING MANUAL
EM_MultiV_Ducted_IndoorUnits_4_16 DUCTED INDOOR UNIT ENGINEERING MANUAL High Static Ducted 7,500 to 95,900 Btu/h Low Static Ducted 7,500 to 24,000 Btu/h Low Static Built In Ducted 7,500 to 24,200 Btu/h
More informationFFQN-C, FCRN-E, FFRN-C
R410A TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FCQN-E, FFQN-C, FCRN-E, FFRN-C Cooling only & Heatpump [50Hz] DAIKIN_FFRN.indb i 12/27/2012 9:28:06 AM DAIKIN_FFRN.indb ii
More informationDigital Inverter 4 series
TCTC-E14-LC005-2 Digital Inverter 4 series Outdoor Unit RAV-SM304ATP-E RAV-SM304ATJP-E RAV-SM4ATP-E RAV-SM4ATJP-E I ndoor Unit RAV-SM307KRTP-E RAV-SM7KRTP-E RAV-SM7CTP-E RAV-SM304MUT-E RAV-SM4MUT-E RAV-SM304SDT-E
More informationUATYQ-ABAY1. Air Conditioning Technical Data > UATYQ20ABAY1 > UATYQ25ABAY1 > UATYQ30ABAY1 > UATYQ45ABAY1 > UATYQ50ABAY1 > UATYQ55ABAY1
Conditioning Technical Data UATYQ-ABAY > UATYQ20ABAY > UATYQ25ABAY > UATYQ0ABAY > UATYQ45ABAY > UATYQ50ABAY > UATYQ55ABAY > UATYQ65ABAY > UATYQ75ABAY > UATYQ90ABAY > UATYQ00ABAY > UATYQ5ABAY Single Unit
More information1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units
t i t l r - I Features s e Cs m B ne d E Ue V s 7 ya P os e oc Q dvn S nr ox VF C Reduction of power consumption of 20% (compared to FXSQ-M8 series) through use of new DC fan Improved comfort thanks to
More informationDC INVERTER DUCTED AIR CONDITIONERS
DC INVERTER DUCTED AIR CONDITIONERS DC Inverter Ducted Air Conditioners Technology. With over 5% of revenue invested in research and development programs, Hitachi has developed world leading technologies
More informationVMDA Concealed Medium Static Ducted Indoor Models - 60HZ
VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDA Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Slim, compact design for limited space requirements. Installs out of sight between the
More informationTechnical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph
Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4
More informationEngineering Data Book
40VMA Outside Air Processing Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationVMDB Concealed Medium Static Ducted Indoor Models - 60HZ
VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDB Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Bulletin No. 210711 March 2018 Slim, compact design for limited space requirements. Installs
More informationModel RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2
2-8 GENERAL DATA 2.3. INVERTER SERIES 2.3.1. INVERTER (RAS-25YHA2/35YHA3/50YHA2/60YHA2/70YHA2/80YHA2) Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2 Power Supply From Outdoor Unit
More informationVertical Air Handling Unit type
Vertical Air Handling Unit type Engineering Databook MMD-AP0120VHG2UL MMD-AP0180VHG2UL MMD-AP0240VHG2UL MMD-AP0300VHG2UL MMD-AP0360VHG2UL MMD-AP0420VHG2UL MMD-AP0480VHG2UL MMD-AP0600VHG2UL Contents 1.
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationTechnical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph
Technical Service Manual TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 2015 1. Features...2 2. Specifications...3 3. Dimensions...7 4.Service Spaces...8 5.Piping
More information1. Unit selection (based on cooling load)
. Outdoor unit 1. Unit selection (based on cooling load) 11. Indoor unit selection Select the indoor unit based upon cooling load and unit capacity. (The indoor unit capacity should larger than the load.)
More informationtechnical data air conditioning systems MXS-B Multi Application Split Sky Air
technical data MXS-B Multi Application air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment
More informationtechnical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air
technical data RKS-C RKS-B Pair Application, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help
More informationVWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ
PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ Bulletin No. 210712 March 2018 Low-sound, three-speed Wall Mount with LED display offers three
More informationSuperior Performance in Extreme Temperature Submittal Data: SAP09HP230V1A
Superior Performance in Extreme Temperature Submittal Data: 9,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationINVERTER DUCTED SYSTEMS
INVERTER DUCTED SYSTEMS What you ll find inside: DC Twin-Rotary Compressor Inverter Ducted advantages Controllers Product specifications Energy Efficient Powerful Operation Flexible Application 1 About
More informationLandmark Rooftop Packaged Units
Landmark Rooftop Packaged Units Engineered for superior performance and reliability Exclusively distributed by AUS - 13 23 50 www.lennoxaus.com.au NZ - 0800 653 330 www.lennoxnz.co.nz 1 Landmark Rooftop
More informationOutdoor Units, 50Hz, R410A
LG AIR CONDITIONERS Outdoor Units, 50Hz, R410A 20 Yoido-dong, Youngdungpo-gu, Yoido P.O.Box 355 Seoul 150-721, Korea Phone: 3777-7969 Fax: 3777-5137/8 http://www.lge.com Approvals: EN ISO 9001 BS EN ISO
More informationV33B High Efficiency 360 Cassette Indoor Models - 60HZ
PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven
More informationMODEL: DCT 35 INV-Si DCT 50 INV-Si DCT 70 INV-Si DCT 100 INV-Si DCT 140 INV-Si DCT 170 INV-Si
MODEL: DCT 35 INV-Si DCT 50 INV-Si DCT 70 INV-Si DCT 100 INV-Si DCT 140 INV-Si DCT 170 INV-Si Part 1 General Information.. 1 Part 2 Indoor Units. Part 3 Outdoor Units. Part 5 Control... Part 6 Control
More informationRoom Air Conditioner SVC MANUAL(Exploded View)
Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : AS-W363DGU1(Set) ASNW363DGU1 ASUW363DGU1 AS-W303DGU1(Set) ASNW303DGU1 ASUW303DGU1 CAUTION Before Servicing
More informationVRF. For Commercial and Light Commercial
118 VRF For Commercial and Light Commercial 119 SOLUTIONS SMALL OFFICES Fujitsu General provides perfect total air conditioning systems that take into account energy saving, low noise, comfortable airflow,
More informationUMXCA/UMXCBA ECVA/ECVBA
OUTDOOR UNITS Models: 801.1 1001.1 1201.1 1501.1 1602.2 2002.2 2402.2 3002.2 3502.2 4002.2 4502.2 Cooling Capacities: from 25,9 kw to 134,7 kw Heating Capacities: from 27,3 kw to 142,4 kw INDOOR UNITS
More informationBosch BOVA Split System Heat Pump
Bosch BOVA Split System Heat Pump Condensing Units Up to 18 SEER 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BOVA Product Specifications Data subject to change 03.2018 Bosch Thermotechnology
More informationSPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE
TECHNICAL SELECTION DATA SPLIT DUCTED UNIT 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE AXIAL UNIT FEATURES Scroll Compressor Multiple Speed Outdoor Fans Louvred Outdoor Coil Guard Pre-charged with
More informationLow Static Pressure Duct(V shape evaporator)
Low Static Pressure Duct (V shape evaporator) 1. Features... 116 2. Specifications... 118 3. Dimensions... 121 4. Service Spaces... 123 5. Piping Diagrams... 124 7.Fan Performance... 126 8.Capacity Tables...
More informationLG HVAC SOLUTION. LG Electronics. Distributed by. Copyright 2017 LG Electronics. All rights reserved.
2 0 1 7 2017 LG HVAC SOLUTION LG Electronics http://www.lg.com http://partner.lge.com Distributed by Copyright 2017 LG Electronics. All rights reserved. ULTIMATE INVERTER COMPRESSOR As the core technology
More informationHigh Wall Type ( 2 Series )
Jan.05' Engineering Data High Wall Type ( 2 Series ) Indoor Unit MMK-AP0072H MMK-AP0092H MMK-AP0122H 1. Equipments 2. Technical Specifications 3. Dimensional Drawing 4. Wiring Diagram 5. Refrigerant Cycle
More informationUniversal Air Conditioner SVC MANUAL(Exploded View)
http://biz.lgservice.com Universal Air Conditioner SVC MANUAL(Exploded View) MDEL : AUUW306C (UU30W UEC) CAUTIN Before Servicing the unit, read the safety precautions in Standard SVC manual. nly for authorized
More informationCompact Four-way Cassette Type
1. Features... 34 2. Specifications... 35 3. Dimensions... 37 4. Service Spaces... 38 5. Piping Diagrams (EXV beside)... 39 6. Wiring Diagrams... 40 7. Capacity Tables... 41 8. Electrical Characteristics...
More informationVHIA High-Static Ducted Indoor Units - 60HZ
PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage
More informationPREMIUM INVERTER DUCTED AIR CONDITIONING
PREMIUM INVERTER DUCTED AIR CONDITIONING PANASONIC LEADS THE WAY Ducted Air Conditioning Specialists With more than 30 years of experience, exporting to more than 120 countries around the world, Panasonic
More informationMULTI SPLIT SYSTEM AIR CONDITIONERS
MULTI SPLIT SYSTEM AIR CONDITIONERS Come home to comfort with LG The Total HVAC and Energy Solution Provider Ever since manufacturing orea s first homegrown air conditioner in 1968, L has remained at the
More informationtechnical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air
technical data MA-GZ7 Multi Model Application air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect human health
More informationTechnical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.
Technical Support Division 2012.10 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics
More informationAir Conditioning Technical Data RZQG-L(8)Y1
Air Conditioning Technical Data RZQG-L(8)Y TABLE OF CONTENTS RZQG-L(8)Y Features............................................................. 2 2 Specifications.......................................................
More informationSplit-Sky Air RMX-JZ Super Multi Plus
TECHNICAL DATA Split-Sky Air RMX-JZ Super Multi Plus Split Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment from the potential
More informationHPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM
1 Lmf Clima 216 FERRARO GROUP HPR Heat recovery units HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM from 7 to 23. m³/h Supporting structure in extruded aluminium profiles and curtain
More informationtechnical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air
technical data FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette Multi (950mm Split Heat x 950mm) Pump (edited) air conditioning systems Split Sky Air Outdoor Units R40A MXS-DAVMB_E2VB_E7VB Features V i
More informationRESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS
RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS A Better Life, A Better World As we move towards our Centenary in 2018, our new brand slogan encapsulates Panasonic s
More informationPRPDF14 PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT REFRIGERANT SYSTEM HEAT EXCHANGER CABINET CONSTRUCTION ACCESSORIES WARRANTY BLOWER
PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT FORM NO. -100 (01/2017) REFRIGERANT SYSTEM Environmentally friendly R410A refrigerant Copper tubing with enhanced fin coils Internal service gauge
More informationDC INVERTER VRF SYSTEMS C-VRF
DC INVERTER VRF SYSTEMS C-VRF Index VRF System Overview 4 C-VRF 9 Advantages 10 Benefits For Users 14 Benefits For Installers 18 C-VRF MINI 27 Advantages 28 Indoor Units 33 Indoor Units Line Up 34 Indoor
More informationLG Multi Split Air Conditioners
AUS-MUF111 New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 266 PH : 02-8805-4000 FAX : 02-8805- Queensland 23 Terrace Place MURARRIE QLD 4 PH : 0-8-000 FAX : 0--41 Victoria 3 John Deere
More information