technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

Size: px
Start display at page:

Download "technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB"

Transcription

1 technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems

2 technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems

3 TABLE OF CONTENTS FXFQ-P9VEB 1 Specifications Technical Specifications Safety device settings Options Capacity tables Cooling capacity tables Heating capacity tables Dimensional drawing & centre of gravity Dimensional drawing for standard panel Dimensional drawing for auto leaning panel Dimensional drawing with accessories Centre of gravity Piping diagram Wiring diagram Wiring diagram Sound data Sound pressure spectrum Sound power spectrum Air flow pattern

4 o l F d n s s t m i e Bn ut EU s V y 8 r S P o - o Q dvf nr X FI V 1 Specifications w R 1-1 Technical Specifications FXFQ20P9VEB FXFQ25P9VEB FXFQ32P9VEB FXFQ40P9VEB FXFQ50P9VEB Capacity Cooling Nominal kw Heating Nominal kw Power Input (50Hz) Cooling Nominal kw Heating Nominal kw Power Input (60Hz) Cooling Nominal kw Heating Nominal kw Dimensions Unit Height mm 204 Width mm 840 Depth mm 840 Packed unit Height mm 220 Width mm 882 Depth mm 882 Weight Unit kg Packed Unit kg Casing Material Galvanised steel plate Heat Exchanger Type Cross fin coil Type Nr of Rows 2 Inside length mm 2,096 Outside length mm 2,152 Fin Pitch mm 1.2 Nr of Passes Face Area m² Nr of Stages 6 8 Empty Tubeplate Hole 4 0 Fan Type Turbo fan Quantity 1 Air Flow Rate (50Hz) Cooling High m³/min Low m³/min Heating High m³/min Low m³/min Air Flow Rate (60Hz) Cooling High m³/min Low m³/min Heating High m³/min Low m³/min Fan Motor Quantity 1 Model QTS48D11M Steps 2 Output (high) W 56 Refrigerant Type R-410A Sound power level Cooling Nominal dba Sound pressure level Cooling High dba Low dba 28 Heating High dba Low dba 28 Piping connections Liquid (OD) Type Flare connection Diameter mm 6.35 Gas Type Flare connection Diameter mm 12.7 Drain Diameter mm VP25 (O.D. 32 / I.D. 25) Heat Insulation Foamed polystyrene/polyethylene Sound absorbing insulation Foamed Polyurethane Decoration Panel Model BYCQ140CW1 Colour White (RAL9010) Dimensions Height mm 50 Width mm 950 Depth mm 950 Weight kg 5.5 2

5 1 Specifications 1-1 Technical Specifications FXFQ20P9VEB FXFQ25P9VEB FXFQ32P9VEB FXFQ40P9VEB FXFQ50P9VEB Decoration Panel 2 Model BYCQ140CW1W Colour White (RAL9010) Dimensions Height mm 50 Width mm 950 Depth mm 950 Weight kg 5.5 Decoration Panel 3 Model BYCQ140CGW1 Colour White (RAL9010) Dimensions Height mm 130 Width mm 950 Depth mm 950 Weight kg 5.5 Air Filter Resin net with mold resistance Standard Accessories Operation manual Installation manual Drain hose Clamp for drain hose Washer for hanger bracket Screws Installation guide Insulation for fitting Sealing pads Drain sealing pad Notes Cooling: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; equivalent piping length: 7.5m; level difference: Heating: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB; equivalent refrigerant piping: 7.5m; level difference: The sound pressure values are mentioned for a unit installed with rear suction The sound power level is an absolute value indicating the power which a sound source generates Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat The BYCQ140CW1W has white insulations. Be informed that formation of dirt on white insulations is more visible and that it is consequently not advised to install the BYCQ140W1W decoration panel in environments exposed to concentrations of dirt Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits Maximum allowable voltage range variation between phases is 2% MCA/MFA: MCA = 1.25 x FLA MFA 4 x FLA Next lower standard fuse rating minimum 16A Select wire size based on the value of MCA Instead of a fuse, use a circuit breaker Power supply Name VE Phase 1~ Frequency Hz 50/60 Voltage V /220 Voltage range Min. -10 Max. 10 Current - 50Hz Minimum circuit amps (MCA) A Maximum fuse amps (MFA) A 16 Full load amps (FLA) A Current - 60Hz Minimum circuit amps (MCA) A Maximum fuse amps (MFA) A 16 Full load amps (FLA) A

6 1 Specifications 1-1 Technical Specifications FXFQ63P9VEB FXFQ80P9VEB FXFQ100P9VEB FXFQ125P9VEB Capacity Cooling Nominal kw Heating Nominal kw Power Input (50Hz) Cooling Nominal kw Heating Nominal kw Power Input (60Hz) Cooling Nominal kw Heating Nominal kw Dimensions Unit Height mm Width mm 840 Depth mm 840 Packed Unit Height mm Width mm 882 Depth mm 882 Weight Unit kg Packed Unit kg Casing Material Galvanised steel plate Heat Exchanger Type Cross fin coil Type Nr of Rows 2 Inside length mm 2,096 Outside length mm 2,152 Fin Pitch mm 1.2 Nr of Passes Face Area m² Nr of Stages Empty Tubeplate Hole 0 Fan Type Turbo fan Quantity 1 Air Flow Rate (50Hz) Cooling High m³/min Low m³/min Heating High m³/min Low m³/min Air Flow Rate (60Hz) Cooling High m³/min Low m³/min Heating High m³/min Low m³/min Fan Motor Quantity 1 Model QTS48D11M QTS48C15M Steps 2 Output (high) W Refrigerant Type R-410A Sound power level Cooling Nominal dba Sound pressure level Cooling High dba Low dba Heating High dba Low dba Piping connections Liquid (OD) Type Flare connection Diameter mm 9.52 Gas Type Flare connection Diameter mm 15.9 Drain Diameter mm VP25 (O.D. 32 / I.D. 25) Heat Insulation Foamed polystyrene/polyethylene Sound absorbing insulation Foamed Polyurethane Decoration Panel Model BYCQ140CW1 Colour White (RAL9010) Dimensions Height mm 50 Width mm 950 Depth mm 950 Weight kg 5.5 4

7 1 Specifications 1-1 Technical Specifications FXFQ63P9VEB FXFQ80P9VEB FXFQ100P9VEB FXFQ125P9VEB Decoration Panel 2 Model BYCQ140CW1W Colour White (RAL9010) Dimensions Height mm 50 Width mm 950 Depth mm 950 Weight kg 5.5 Decoration Panel 3 Model BYCQ140CGW1 Colour White (RAL9010) Dimensions Height mm 130 Width mm 950 Depth mm 950 Weight kg 5.5 Air Filter Resin net with mold resistance Standard Accessories Operation manual Installation manual Drain hose Clamp for drain hose Washer for hanger bracket Screws Installation guide Insulation for fitting Sealing pads Drain sealing pad Notes Cooling: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; equivalent piping length: 7.5m; level difference: Heating: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB; equivalent refrigerant piping: 7.5m; level difference: The sound pressure values are mentioned for a unit installed with rear suction The sound power level is an absolute value indicating the power which a sound source generates Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat The BYCQ140CW1W has white insulations. Be informed that formation of dirt on white insulations is more visible and that it is consequently not advised to install the BYCQ140W1W decoration panel in environments exposed to concentrations of dirt Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits Maximum allowable voltage range variation between phases is 2% MCA/MFA: MCA = 1.25 x FLA MFA 4 x FLA Next lower standard fuse rating minimum 16A Select wire size based on the value of MCA Instead of a fuse, use a circuit breaker Power supply Name VE Phase 1~ Frequency Hz 50/60 Voltage V /220 Voltage range Min. -10 Max. 10 Current - 50Hz Minimum circuit amps (MCA) A Maximum fuse amps (MFA) A 16 Full load amps (FLA) A Current - 60Hz Minimum circuit amps (MCA) A Maximum fuse amps (MFA) A 16 Full load amps (FLA) A

8 2 Safety device settings Safety devices FXFQ20P9 FXFQ25P9 FXFQ32P9 FXFQ40P9 FXFQ50P9 FXFQ63P9 FXFQ80P9 FXFQ100P9 FXFQ125P9 PC board fuse 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A Fan motor thermal fuse C Fan motor thermal protector C OFF: 108 ±5 (ON: 96 ±15 ) OFF: 108 ±5 (ON: 96 ±15 ) OFF: 108 ±5 (ON: 96 ±15 ) OFF: 108 ±5 (ON: 96 ±15 ) OFF: 108 ±5 (ON: 96 ±15 ) OFF: 108 ±5 (ON: 96 ±15 ) OFF: 108 ±5 (ON: 96 ±15 ) OFF: 108 ±5 (ON: 96 ±15 ) OFF: 108 ±5 (ON: 96 ±15 ) Drain pump fuse C TW

9 3 Options FXFQ-P9 Max fresh air intake volume table The maximum intake air flow volume is following table. If the intake air flow volume is too large, the operating sound may rise or detection of the indoor unit suction temperature may be affected. FXFQ P Max fresh air intake volume (m/min.) The rise of operating sound at with fresh air intake kit Nominal sound pressure level The rise sound from nominal sound pressure level (dba) Fresh air intake volume (m`/min) 4D

10 4 Capacity tables 4-1 Cooling capacity tables FXFQ-P9 Unit size Nominal capacity TC: Total capacity;kw SHC: Sensible capacity;kw Indoor air temperature Outdoor 14.0WB 16.0WB 18.0WB 19.0WB 20.0WB 22.0WB 24.0WB air temp. 20.0DB 23.0DB 26.0DB 27.0DB 28.0DB 30.0DB 32.0DB CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TW

11 4 Capacity tables 4-1 Cooling capacity tables FXFQ-P9 TC: Total capacity;kw SHC: Sensible capacity;kw Unit size Nominal Outdoor Indoor air temperature 14.0WB 16.0WB 18.0WB 19.0WB 20.0WB 22.0WB 24.0WB air temp. capacity 20.0DB 23.0DB 26.0DB 27.0DB 28.0DB 30.0DB 32.0DB CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TW

12 4 Capacity tables 4-2 Heating capacity tables FXFQ-P9 Unit size Nominal Capacity Outdoor air temp Indoor air temp.: CDB CDB CWB KW KW KW KW KW KW TW A 10

13 4 Capacity tables 4-2 Heating capacity tables FXFQ-P9 Nominal Capacity Outdoor air temp Indoor air temp.: CDB Unit size ( CDB) ( CWB) KW KW KW KW KW KW TW A 11

14 5 Dimensional drawing & centre of gravity 5-1 Dimensional drawing for standard panel FXFQ20,25,32,40,50,63P9 Piping side Drain side (Ceiling opening) 300 or less 710 (Suspension position 950 see note (Suspension position (Ceiling opening) SEE NOTE 4 Nr Name Description 1 Liquid pipe connection ø A flare connection 2 Gas pipe connection ø B flare connection 3 Drain pipe connection VP25 (O.D. ø 32 /I.D. ø 25) 4 Power supply entry hole 5 Transmission wiring entry hole 6 Air discharge opening 7 Air suction grille 8 Corner decoration cover 9 Drain hose O.D. ø 32 /I.D. ø Knock out hole MODEL A B FXFQ20-50P FXFQ63P VIEW A VIEW B Adjustable (0-675) 175 Hanging bolt 4 x M8~M Location of the nameplates - Unit body: on the control box cover. - Decoration panel: on the panel frame at the motor side under the corner cover 2 When installing an optional accessory, refer to the installation drawings. - For the fresh air intake kit an inspection port is necessary SEE NOTE 4 SEE NOTE or more (installation space) 4 Make sure the spacing between the ceiling and the cassette is no more than 35mm. MAX ceiling opening: 9. 5 When the conditions exceed 30 C and RH 80% in the ceiling or fresh air is inducted into the ceiling, an additional insulation is required (polyethylene foam, thickness or more). SEE NOTE 6 20m or more 150m or more (*) EXTERNAL SURFACE LIGHT VENTILATOR 1500 or more 2000 or more 4000 or more 20m or more 150m or more (*) 150m or more (*) OTHER UNIT 150m or more (*) (*) In case a discharge opening is closed with the sealing member option, the distance of 150m can be reduced to 50m on the closed side. 3 In case of using an infrared remote control, this position will be a signal receiver. Refer to the drawing of the infrared remote control for more detail. 6 Please respect the distances as shown on the figure 3TW B FXFQ80,100P9 Piping side Drain side (Ceiling opening) 300 or less 710 (Suspension position 950 see note (Suspension position (Ceiling opening) SEE NOTE 4 Nr Name Description 1 Liquid pipe connection ø 9.52 flare connection 2 Gas pipe connection ø flare connection 3 Drain pipe connection VP25 (O.D. ø 32 /I.D. ø 25) 4 Power supply entry hole 5 Transmission wiring entry hole 6 Air discharge opening 7 Air suction grille 8 Corner decoration cover 9 Drain hose O.D. ø 32 /I.D. ø Knock out hole VIEW A 420 VIEW B Adjustable (0-675) 175 Hanging bolt 4 x M8~M Location of the nameplates - Unit body: on the control box cover. - Decoration panel: on the panel frame at the motor side under the corner cover 2 When installing an optional accessory, refer to the installation drawings. - For the fresh air intake kit an inspection port is necessary SEE NOTE 4 SEE NOTE or more (installation space) 4 Make sure the spacing between the ceiling and the cassette is no more than 35mm. MAX ceiling opening: 9. 5 When the conditions exceed 30 C and RH 80% in the ceiling or fresh air is inducted into the ceiling, an additional insulation is required (polyethylene foam, thickness or more). SEE NOTE 6 20m or more 150m or more (*) EXTERNAL SURFACE LIGHT VENTILATOR 1500 or more 2000 or more 4000 or more 20m or more 150m or more (*) 150m or more (*) OTHER UNIT 150m or more (*) (*) In case a discharge opening is closed with the sealing member option, the distance of 150m can be reduced to 50m on the closed side. 3 In case of using an infrared remote control, this position will be a signal receiver. Refer to the drawing of the infrared remote control for more detail. 6 Please respect the distances as shown on the figure 3TW B 12

15 5 Dimensional drawing & centre of gravity 5-1 Dimensional drawing for standard panel FXFQ125P9 950 See note or less 860 ~ 910 (Ceiling opening) 710 (Suspension position) 420 See note 4 Piping side Drain side View A (Suspension position) (Ceiling opening) Nr Name Description 1 Liquid pipe connection ø9.52 flare connection 2 Gas pipe connection ø15.90 flare connection 3 Drain pipe connection VP25 (O.D. ø32, I.D. ø25) 4 Power supply connection 5 Transmission wiring connection 6 Air discharge opening 7 Air suction grill 8 Corner decoration cover 9 Drain house O.D. ø32 I.D. ø Adjustable (0~675) Ventilator External surface light 1500 or more 2000 or more 4000 or more Other unit Hanging bolt 4 x M8-M Location of the nameplates: - Unit body: on the control box cover. - Decoration panel: on the panel frame at the motor side under the corner cover 2 When installing an optional accessory, refer to the installation drawings - For the fresh air intake kit... an inspection port is necessary See note 4 See note or more (Installation space) 200 mm or more 1500 mm or more (*) 1500 mm or more (*) 1500 mm or more (*) 200 mm or more 1500 mm or more (*) (*) In case a discharge opening is closed with the sealing member option, the distance of 1500 mm can be reduced to 500 mm on the closed side. 3 In case of using an Infrared remote control, this position will be a signal receiver. Refer to the drawing of the infrared remote control for more detail 4 Make sure the spacing between the ceiling and the cassette is no more than 35 mm. Max ceiling opening: 910 mm. 5 When the conditions exceed 30 C and RH 80% in the ceiling or fresh air is inducted into the ceiling, an additional insulation is required (polyethylene foam, thickness 10 mm or more.) 6 Please respect the distances as shown above 3TW C 13

16 5 Dimensional drawing & centre of gravity 5-2 Dimensional drawing for auto leaning panel FXFQ20-63P9VEB Piping side Drain side 300 or less 860~910 (Ceiling opening) 710 (Suspension position) 780 (Suspension position) 860~910 (Ceiling opening) See note 3 Model A B FCQ FCQ50-60, FXFQ20~ FCQ71, FXFQ Nr Name Description 1 Liquid pipe connection ØA fl are connection 2 Gas pipe connection ØB fl are connection 3 Drain pipe connection VP25 (O.D.Ø32, I.D. Ø25) 4 Power supply entry hole 5 Transmission wiring entry hole 6 Air discharge opening 7 Air suction grille 8 Corner decoration cover 9 Drain hose O.D.Ø32, I.D. Ø26 10 Knock out hole VIEW A 6. VIEW B Please respect the distances as shown on fi gure below Adjustable (0~675) or more External surface light (*1) 2000 or more Ventilator 4000 or more Other unit Hanging bolt Location of the nameplates: Unit body: on the control box. Decoration panel: on the panel frame at the motor side under the corner cover When installing an optional accessory, refer to the installation drawings. For the fresh air intake kit an inspection part is necessary Make sure the spacing between the ceiling and the cassette is no more than 35mm. Max. ceiling opening: 9 When the conditions exceed 30 C and RH 80% in de ceiling or fresh air is included into the ceiling, an additional insulation is required (polyethylene foam, thickness or more). 5. See note 3 See note 3 Installation direction Piping Dust opening Suction grill 1500 or more (Installation space) Piping (*1) Does not count for build in light (*2) Space needed to enter with vacuum-cleaner tube. (*3) Keep the exhaust of decoration panel free. 20m or more (*4) 150m or more (*4) 20m or more (*4) 150m or more (*4) 150m or more (*4) 150m or more (*4) (*4) In case a discharge opening is closed with the sealing member option, the distance of 150m can be reduced to 500 mm on the closed side. 3TW FXFQ80-100P9VEB Piping side Drain side 300 or less 860~910 (Ceiling opening) 710 (Suspension position) 780 (Suspension position) 860~910 (Ceiling opening) See note 3 Nr Name Description 1 Liquid pipe connection Ø9.52 fl are connection 2 Gas pipe connection Ø15.90 fl are connection 3 Drain pipe connection VP25 (O.D.Ø32, I.D. Ø25) 4 Power supply entry hole 5 Transmission wiring entry hole 6 Air discharge opening 7 Air suction grille 8 Corner decoration cover 9 Drain hose O.D.Ø32, I.D. Ø26 10 Knock out hole VIEW A 6. VIEW B Please respect the distances as shown on fi gure below Adjustable (0~675) or more External surface light (*1) 2000 or more Ventilator 4000 or more Other unit Hanging bolt Location of the nameplates: Unit body: on the control box. Decoration panel: on the panel frame at the motor side under the corner cover When installing an optional accessory, refer to the installation drawings. For the fresh air intake kit an inspection part is necessary Make sure the spacing between the ceiling and the cassette is no more than 35mm. Max. ceiling opening: 9 When the conditions exceed 30 C and RH 80% in de ceiling or fresh air is included into the ceiling, an additional insulation is required (polyethylene foam, thickness or more). 5. See note 3 See note 3 Installation direction Piping Dust opening Suction grill 1500 or more (Installation space) Piping (*1) Does not count for build in light (*2) Space needed to enter with vacuum-cleaner tube. (*3) Keep the exhaust of decoration panel free. 20m or more (*4) 150m or more (*4) 20m or more (*4) 150m or more (*4) 150m or more (*4) 150m or more (*4) (*4) In case a discharge opening is closed with the sealing member option, the distance of 150m can be reduced to 500 mm on the closed side. 3TW

17 5 Dimensional drawing & centre of gravity 5-2 Dimensional drawing for auto leaning panel FXFQ125P9VEB Piping side Drain side 300 or less 860~910 (Ceiling opening) 710 (Suspension position) 780 (Suspension position) 860~910 (Ceiling opening) See note 3 Nr Name Description 1 Liquid pipe connection Ø9.52 fl are connection 2 Gas pipe connection Ø15.90 fl are connection 3 Drain pipe connection VP25 (O.D.Ø32, I.D. Ø25) 4 Power supply entry hole 5 Transmission wiring entry hole 6 Air discharge opening 7 Air suction grille 8 Corner decoration cover 9 Drain hose O.D.Ø32, I.D. Ø26 10 Knock out hole VIEW A 6. VIEW B Please respect the distances as shown on fi gure below Adjustable (0~675) or more External surface light (*1) 2000 or more Ventilator 4000 or more Other unit Hanging bolt Location of the nameplates: Unit body: on the control box. Decoration panel: on the panel frame at the motor side under the corner cover When installing an optional accessory, refer to the installation drawings. For the fresh air intake kit an inspection part is necessary Make sure the spacing between the ceiling and the cassette is no more than 35mm. Max. ceiling opening: 9 When the conditions exceed 30 C and RH 80% in de ceiling or fresh air is included into the ceiling, an additional insulation is required (polyethylene foam, thickness or more). 5. See note 3 See note 3 Installation direction Piping Dust opening Suction grill 1500 or more (Installation space) Piping (*1) Does not count for build in light (*2) Space needed to enter with vacuum-cleaner tube. (*3) Keep the exhaust of decoration panel free. 20m or more (*4) 150m or more (*4) 20m or more (*4) 150m or more (*4) 150m or more (*4) 150m or more (*4) (*4) In case a discharge opening is closed with the sealing member option, the distance of 150m can be reduced to 500 mm on the closed side. 3TW

18 5 Dimensional drawing & centre of gravity 5-3 Dimensional drawing with accessories FXFQ20,25,32,40,50,63P9 Service acces panel: 450x450 mm or more (Refer to note: 1) Pipe connection side Note: 3 Service acces panel: 450 x 450 mm or more Drain connection side Installation service access panel (Refer to note: 1) view Note: 3 1 When installing this kit, inspection hatch is necessary. (It is necessary when servicing.) Either one of inspection hatches must be installed. 2 Field construction. 3 The corner air outlet of this part must be shut. 4 In case of mounting a duct fan, make sure to use a wiring adapter for electrical appendices and link with the indoor unit fan. 5 The intake air flow rate is recommended to be 20% or less of the H speed air flow rate. If the intake air flow rate is too large, the operating sound may rise or detection of the indoor unit suction 455 (Ceiling opening space) temperature may be affected. Connecting chamber mounting space 6 It indicates the distance between the T-tube inlet and the indoor unit inlet when the T-tube is connected. Static pressure of chamber (Pa) Air flow rate (m 3 /min) Ventilation resistance in chamber (Note: 6) Nr Name Description 1 Indoor unit 2 Decoration panel 3 Suction chamber 4 Connecting chamber (Right) 5 Connecting chamber (Left) (1000) Inlet T-tube Field supply 3D FXFQ80,100P9 Service acces panel: 450x450 mm or more (Refer to note: 1) Pipe connection side Note: 3 Service acces panel: 450 x 450 mm or more Drain connection side Installation service access panel (Refer to note: 1) Note: 3 1 When installing this kit, inspection hatch is necessary. (It is necessary when servicing.) Either one of inspection hatchs must be installed. 2 Field construction. 3 The corner air outlet of this part must be shut. 4 In case of mounting a duct fan, make sure to use a wiring adapter for electrical appendices and link with the indoor unit fan. 5 The intake air flow rate is recommended to be 20% or less of the H speed air flow rate. If the intake air flow rate is too large, the operating sound may rise or detection of the indoor unit suction 455 (Ceiling opening space) temperature may be affected. Connecting chamber mounting space 6 It indicates the distance between the T-tube inlet and the indoor unit inlet when the T-tube is connected. Static pressure of chamber (Pa) Air flow rate (m 3 /min) Ventilation resistance in chamber (Note: 6) Nr Name Description 1 Indoor unit 2 Decoration panel 3 Suction chamber 4 Connecting chamber (Right) 5 Connecting chamber (Left) Inlet T-tube Field supply 3D

19 5 Dimensional drawing & centre of gravity 5-3 Dimensional drawing with accessories FXFQ125P9 Service acces panel: 450x450 mm or more (Refer to note: 1) Pipe connection side Note: 3 Installation service access panel Service acces panel: 450 x 450 mm or more (Refer to note: 1) Drain connection side Note: 3 1 When installing this kit, inspection hatch is necessary. (It is necessary when servicing.) Either one of inspection hatchs must be installed. 2 Field construction. 3 The corner air outlet of this part must be shut. 4 In case of mounting a duct fan, make sure to use a wiring adapter for electrical appendices and link with the indoor unit fan. 5 The intake air flow rate is recommended to be 20% or less of the H speed air flow rate. If the intake air flow rate is too large, the operating sound may rise or detection of the indoor unit suction 455 (Ceiling opening space) temperature may be affected. Connecting chamber mounting space 6 It indicates the distance between the T-tube inlet and the indoor unit inlet when the T-tube is connected. 348 Static pressure of chamber (Pa) Air flow rate (m 3 /min) Ventilation resistance in chamber (Note: 6) Nr Name Description 1 Indoor unit 2 Decoration panel 3 Suction chamber 4 Connecting chamber (Right) 5 Connecting chamber (Left) Inlet T-tube Field supply 3D

20 5 Dimensional drawing & centre of gravity 5-4 Centre of gravity FXFQ-P9 Models A B C D FXFQ20~ FXFQ80~ FXFQ TW

21 6 Piping diagram FXFQ-P9 Heat exchanger Fan Liquid pipe connection port Refrigerant flow Filter Electronic expansion valve Filter Gas pipe connection port Cooling Heating Refrigerant pipe connection port diameters Model Gas Liquid FXFQ20,25,32,50P Ø12.70 Ø6.35 FXFQ63,80,100,125P Ø15.90 Ø9.52 3TW

22 7 Wiring diagram 7-1 Wiring diagram FXFQ20-125P 20~125-Class (22~140-Class) indoor 35~60 CLASS Control box 220~240/220V~50/60Hz Receiver display unit Input from outside (note3) Central remote control (note1) Wired remote control 20~63-Class (22~71-Class) 80~125-Class (90~140-Class) Exept for self cleaning panel (note 5) A1P Printed circuit board Receiver display unit (attached to wireless remote controller) A2P Printed circuit board (Humidity sensor unit) A3P Printed circuit board HAP Light emitting diode (Service monitor green) A4P Printed circuit board KPR Magnetic relay (M1P) BS1 Push button (On/off) M1F Motor (Indoor fan) H1P Light emitting diode (On-red) M1P Motor (Drain pump) H2P Light emitting diode (Timer-green) M1S Motor (Swing fl ap) H3P Light emitting diode (Filter sign-red) PS Power supply circuit H4P Light emitting diode (Defrost - orange) R1T Thermistor (Air) SS1 Selector switch (Main/sub) R2T Thermistor (Coil) SS2 Selector switch (Wireless address set) RC Signal receiver circuit Connector for optional parts S1L Float switch X24A Connector (Wireless remote control) SS1 Selector switch (Emergency) X33A Connector (Adapter for wiring) TC Signal transmission circuit X35A Connector (Group control adapter) X1M Terminal strip X70A Connector (Self cleaning panel) X2M Terminal strip Wired remote control Z1C Ferrite core R1T Thermistor (Air) SS1 Selector switch (Main/sub) : Terminal strip Colors: RED Red YLW Yellow BRN Brown : Connector BLK Black GRN Green GRY Grey : Field wiring WHT White ORG Orange BLU Blue 3TW In case of using a central remote control, connect it to the unit in accordance with th attached installation manual. X24A, X33A and X335A are connected when the optional accessories are being used. When connecting the input wires from outside, forced OFF or ON/OFF control operation can be selected by the remote control. See installation manual for details. Confi rm the method of setting the selector switch (SS1, SS2) by installation manual and engineering data, etc. In case of self cleaning panel follow the self cleaning panel installation instruction. 20

23 8 Sound data 8-1 Sound pressure spectrum FXFQ20P9 FXFQ25P9 Octave band sound pressure level db(0db= μ bar) Approximate threshold hearing for continuous noise Low Hi Octave band sound pressure level db(0db= μ bar) Approximate threshold hearing for continuous noise Low Hi Octave band center frequency (Hz) 4D Octave band center frequency (Hz) 4D Over All (db): (B, G, N is already rectified) Operating conditons: Power source: 220~240V 50Hz/220V 60Hz Cooling: return air temperature: 27 C DB, 19 C WB - outdoor temperature: 35 C DB, 24 C WB Heating: return air temperature: 20 C DB, 15 C WB - outdoor temperature: 7 C DB, 6 C WB 4 direction discharge Power level (db): Hi 49 Measuring place: Anechoic chamber Location of microphone 0.3m Drain up Scale Mode Hi Low A C Over All (db): (B, G, N is already rectified) Operating conditons: Power source: 220~240V 50Hz/220V 60Hz Cooling: return air temperature: 27 C DB, 19 C WB - outdoor temperature: 35 C DB, 24 C WB Heating: return air temperature: 20 C DB, 15 C WB - outdoor temperature: 7 C DB, 6 C WB 4 direction discharge Power level (db): Hi 49 Measuring place: Anechoic chamber Location of microphone 0.3m Drain up Scale Mode Hi Low A C m 1.5m Mic. position Note: Operation noise differs with operation and ambient conditions. FXFQ32P9 Mic. position Note: Operation noise differs with operation and ambient conditions. FXFQ40P9 Octave band sound pressure level db(0db= μ bar) Approximate threshold hearing for continuous noise Low Hi Octave band sound pressure level db(0db= μ bar) Approximate threshold hearing for continuous noise Low Hi Octave band center frequency (Hz) 4D Octave band center frequency (Hz) 4D Over All (db): (B, G, N is already rectified) Operating conditons: Power source: 220~240V 50Hz/220V 60Hz Cooling: return air temperature: 27 C DB, 19 C WB - outdoor temperature: 35 C DB, 24 C WB Heating: return air temperature: 20 C DB, 15 C WB - outdoor temperature: 7 C DB, 6 C WB 4 direction discharge Power level (db): Hi 49 Measuring place: Anechoic chamber Location of microphone 0.3m Drain up Scale Mode Hi Low A C Over All (db): (B, G, N is already rectified) Operating conditons: Power source: 220~240V 50Hz/220V 60Hz Cooling: return air temperature: 27 C DB, 19 C WB - outdoor temperature: 35 C DB, 24 C WB Heating: return air temperature: 20 C DB, 15 C WB - outdoor temperature: 7 C DB, 6 C WB 4 direction discharge Power level (db): Hi 50 Measuring place: Anechoic chamber Location of microphone 1.5m 0.3m Drain up Scale Mode Hi Low A C m Mic. position Note: Operation noise differs with operation and ambient conditions. Mic. position Note: Operation noise differs with operation and ambient conditions. 21

24 8 Sound data 8-1 Sound pressure spectrum FXFQ50P9 FXFQ63P9 Octave band sound pressure level db(0db= μ bar) Approximate threshold hearing for continuous noise Low Hi Octave band sound pressure level db(0db= μ bar) Approximate threshold hearing for continuous noise Hi (Heating) Low (Heating) Low (cooling) Hi (cooling) Over All (db): (B, G, N is already rectified) Operating conditons: Power source: 220~240V 50Hz/220V 60Hz 4D Cooling: return air temperature: 27 C DB, 19 C WB - outdoor temperature: 35 C DB, 24 C WB Heating: return air temperature: 20 C DB, 15 C WB - outdoor temperature: 7 C DB, 6 C WB 4 direction discharge Power level (db): Hi 51 Measuring place: Anechoic chamber Location of microphone 0.3m Drain up Octave band center frequency (Hz) Scale Mode Hi Low A C Over All (db): (B, G, N is already rectified) Octave band center frequency (Hz) 4D Operating conditons: Power source: V 50Hz/220V 60Hz Cooling: return air temperature: 27 C DB, 19 C WB - outdoor temperature: 35 C DB, 24 C WB Heating: return air temperature: 20 C DB, 15 C WB - outdoor temperature: 7 C DB, 6 C WB 4 direction discharge 0.3m Power level (db): Measuring place: Anechoic chamber Location of microphone Drain up Mode Scale Hi Low Cooling Heating Cooling Heating A C Hi Cooling Heating m Mic. position Note: Operation noise differs with operation and ambient conditions. FXFQ80P9 1.5m Mic. position Note: Operation noise differs with operation and ambient conditions. FXFQ100P9 Octave band sound pressure level db(0db= μ bar) Approximate threshold hearing for continuous noise Low Hi Octave band sound pressure level db(0db= μ bar) Approximate threshold hearing for continuous noise Low (cooling) Hi (cooling) Low (Heating) Hi (Heating) Over All (db): (B, G, N is already rectified) Operating conditons: Power source: 220~240V 50Hz/220V 60Hz 4D Cooling: return air temperature: 27 C DB, 19 C WB - outdoor temperature: 35 C DB, 24 C WB Heating: return air temperature: 20 C DB, 15 C WB - outdoor temperature: 7 C DB, 6 C WB 4 direction discharge Power level (db): Hi 55 Measuring place: Anechoic chamber Location of microphone 0.3m Drain up Octave band center frequency (Hz) Scale Mode Hi Low A C Over All (db): (B, G, N is already rectified) Octave band center frequency (Hz) 4D Operating conditons: Power source: 220~240V 50Hz/220V 60Hz Cooling: return air temperature: 27 C DB, 19 C WB - outdoor temperature: 35 C DB, 24 C WB Heating: return air temperature: 20 C DB, 15 C WB - outdoor temperature: 7 C DB, 6 C WB 4 direction discharge 0.3m Power level (db): Measuring place: Anechoic chamber Location of microphone Drain up Mode Scale Hi Low Cooling Heating Cooling Heating A C Hi Cooling Heating m Mic. position Note: Operation noise differs with operation and ambient conditions. 1.5m Mic. position Note: Operation noise differs with operation and ambient conditions. 22

25 8 Sound data 8-1 Sound pressure spectrum FXFQ125P9 Octave band sound pressure level db(0db= μ bar) Approximate threshold hearing for continuous noise Low High Octave band center frequency (Hz) 4D Over All (db): (B, G, N is already rectified) Operating conditons: Power source: 220~240V 50Hz/220V 60Hz Cooling: return air temperature: 27 C DB, 19 C WB - outdoor temperature: 35 C DB, 24 C WB Heating: return air temperature: 20 C DB, 15 C WB - outdoor temperature: 7 C DB, 6 C WB 4 direction discharge Power level (db): High 61 Measuring place: Anechoic chamber Location of microphone 0.3m Drain up Scale Mode Hi Low A C m Mic. position Note: Operation noise differs with operation and ambient conditions. 23

26 8 Sound data 8-2 Sound power spectrum FXFQ20,25P9 FXFQ32P9 Sound operation level (db) Sound operation level (db) Octave band center frequency (Hz) 1 Data is valid at free field condition. 2 Data is valid at nominal operation condition. 3 dba = A-weighted sound operation level (A-scale according to IEC). 4 Reference acoustic intensity 0dB = 10E-6μW/m 2 5 Curve for FXFQ20,25P9VEB in cooling mode. 4TW Octave band center frequency (Hz) 1 Data is valid at free field condition. 2 Data is valid at nominal operation condition. 3 dba = A-weighted sound operation level (A-scale according to IEC). 4 Reference acoustic intensity 0dB = 10E-6μW/m 2 5 Curve for FXF32P9VEB in cooling mode. 4TW FXFQ40P9 FXFQ50P9 Sound operation level (db) Sound operation level (db) Octave band center frequency (Hz) 4TW Octave band center frequency (Hz) 4TW Data is valid at free field condition. 2 Data is valid at nominal operation condition. 3 dba = A-weighted sound operation level (A-scale according to IEC). 4 Reference acoustic intensity 0dB = 10E-6μW/m 2 5 Curve for FXFQ40P9VEB in cooling mode. 1 Data is valid at free field condition. 2 Data is valid at nominal operation condition. 3 dba = A-weighted sound operation level (A-scale according to IEC). 4 Reference acoustic intensity 0dB = 10E-6μW/m 2 5 Curve for FXFQ50P9VEB in cooling mode. 24

27 8 Sound data 8-2 Sound power spectrum FXFQ63P9 FXFQ80P9 Sound operation level (db) Sound operation level (db) Octave band center frequency (Hz) 4TW Octave band center frequency (Hz) 4TW Data is valid at free field condition. 2 Data is valid at nominal operation condition. 3 dba = A-weighted sound operation level (A-scale according to IEC). 4 Reference acoustic intensity 0dB = 10E-6μW/m 2 5 Curve for FXFQ63P9VEB in cooling mode. 1 Data is valid at free field condition. 2 Data is valid at nominal operation condition. 3 dba = A-weighted sound operation level (A-scale according to IEC). 4 Reference acoustic intensity 0dB = 10E-6μW/m 2 5 Curve for FXFQ80P9VEB in cooling mode. FXFQ100P9 FXFQ125P9 Sound operation level (db) Sound operation level (db) Octave band center frequency (Hz) 1 Data is valid at free field condition. 2 Data is valid at nominal operation condition. 3 dba = A-weighted sound operation level (A-scale according to IEC). 4 Reference acoustic intensity 0dB = 10E-6μW/m 2 5 Curve for FXFQ100P9VEB in cooling mode. 4TW Octave band center frequency (Hz) 1 Data is valid at free field condition. 2 Data is valid at nominal operation condition. 3 dba = A-weighted sound operation level (A-scale according to IEC). 4 Reference acoustic intensity 0dB = 10E-6μW/m 2 5 Curve for FXFQ125P9VEB in cooling mode. 4TW

28 9 Air flow pattern FXFQ20P9 Cooling air velocity distribution 2./s 1.5m/s 1./s 0.5m/s 4m 3m 3m 4m Cooling air temperature distribution 20 C 22 C 24 C 26 C 4m 3m 3m 4m 4D FXFQ25P9 Cooling air velocity distribution 2./s 1.5m/s 1./s 0.5m/s 4m 3m 3m 4m Cooling air temperature distribution 20 C 22 C 24 C 26 C 4m 3m 3m 4m 4D

29 9 Air flow pattern FXFQ32P9 Cooling air velocity distribution 2./s 1.5m/s 1./s 0.5m/s 4m 3m 3m 4m Cooling air temperature distribution 20 C 22 C 24 C 26 C 4m 3m 3m 4m 4D FXFQ40P9 Cooling air velocity distribution 2./s 1.5m/s 1./s 0.5m/s 4m 3m 3m 4m Cooling air temperature distribution 20 C 22 C 24 C 26 C 4m 3m 3m 4m 4D

30 9 Air flow pattern FXFQ50P9 Cooling air velocity distribution 2./s 1.5m/s 1./s 0.5m/s 4m 3m 3m 4m Cooling air temperature distribution 20 C 22 C 24 C 26 C 4m 3m 3m 4m 4D FXFQ63P9 Cooling air velocity distribution 2./s 1.5m/s 1./s 0.5m/s 4m 3m 3m 4m Cooling air temperature distribution 20 C 22 C 24 C 26 C 4m 3m 3m 4m 4D

31 9 Air flow pattern FXFQ80P9 Cooling air velocity distribution 2./s 1.5m/s 1./s0.5m/s 3. 3m 4m 3m 3m 4m Cooling air temperature distribution 20 C 22 C 24 C 26 C 3. 3m 4m 3m 3m 4m 4D FXFQ100P9 Cooling air velocity distribution 2./s 1.5m/s 1./s 0.5m/s 3. 3m 4m 3m 3m 4m Cooling air temperature distribution 20 C 22 C 24 C 26 C 3. 3m 4m 3m 3m 4m 4D

32 9 Air flow pattern FXFQ125P9 Cooling air velocity distribution 2./s 1.5m/s 1./s 0.5m/s 3. 3m 4m 3m 3m 4m Cooling air temperature distribution 3. 3m 20 C 22 C24 C 26 C 4m 3m 3m 4m 4D FXFQ20P9 Heating air velocity distribution 2./s 1.5m/s 1./s 0.5m/s 0.25m/s 4m 3m 3m 4m Heating air temperature distribution 28 C 27 C 26 C 25 C 24 C 23 C 22 C 4m 3m 3m 4m 4D

33 9 Air flow pattern FXFQ25P9 Heating air velocity distribution 2./s 1.5m/s 1./s 0.5m/s 0.25m/s 4m 3m 3m 4m Heating air temperature distribution 28 C 27 C 26 C 25 C 24 C 23 C 22 C 4m 3m 3m 4m 4D FXFQ32P9 Heating air velocity distribution 2./s 1.5m/s 1./s 0.5m/s 0.25m/s 4m 3m 3m 4m Heating air temperature distribution 28 C 27 C 26 C 25 C 24 C 23 C 22 C 4m 3m 3m 4m 4D

34 9 Air flow pattern FXFQ40P9 Heating air velocity distribution 2./s 1.5m/s 1./s 0.5m/s 0.25m/s 4m 3m 3m 4m Heating air temperature distribution 28 C 27 C 26 C 25 C 24 C 23 C 22 C 4m 3m 3m 4m 4D FXFQ50P9 Heating air velocity distribution 2./s 1.5m/s 1./s 0.5m/s 0.25m/s 4m 3m 3m 4m Heating air temperature distribution 28 C 27 C 26 C 25 C 24 C 23 C 22 C 4m 3m 3m 4m 4D

35 9 Air flow pattern FXFQ63P9 Heating air velocity distribution 2./s 1.5m/s 1./s 0.5m/s 0.25m/s 4m 3m 3m 4m Heating air temperature distribution 28 C 27 C 26 C 25 C 24 C 23 C 22 C 4m 3m 3m 4m 4D FXFQ80P9 Heating air velocity distribution 3. 3m 2./s 1.5m/s 1./s 0.5m/s 0.25m/s 4m 3m 3m 4m Heating air temperature distribution 3. 3m 28 C 27 C 26 C 25 C 24 C 23 C 22 C 4m 3m 3m 4m 4D

36 9 Air flow pattern FXFQ100P9 Heating air velocity distribution 3. 3m 2./s 1.5m/s 1./s 0.5m/s 0.25m/s 4m 3m 3m 4m Heating air velocity distribution 3. 3m 28 C 27 C 26 C 25 C 24 C 23 C 22 C 4m 3m 3m 4m 4D FXFQ125P9 Heating air velocity distribution All round air discharge, air flow direction: horizontal 3,2 m 3M 2 m 2,0 m/s 1,5 m/s 1,0 m/s 0,5 m/s 0,25 m/s 1 m 0 m 4 m 3 m 2 m 1 m 0 m 1 m 2 m 3 m 4 m Heating air temperature distribution 3,2 m 3M 28 C 27 C 26 C 25 C 24 C 23 C 22 C 0 m 4 m 3 m 2 m 1 m 0 m 1 m 2 m 3 m 4 m 2 m 1 m 4D

1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units

1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units t i t l r - I Features s e Cs m B ne d E Ue V s 7 ya P os e oc Q dvn S nr ox VF C Reduction of power consumption of 20% (compared to FXSQ-M8 series) through use of new DC fan Improved comfort thanks to

More information

technical data air conditioning systems 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B

technical data air conditioning systems 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B technical data 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B air conditioning systems technical data 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B air conditioning systems Indoor Units

More information

Outdoor Units R-410A ARX-GV1B

Outdoor Units R-410A ARX-GV1B Outdoor Units R-40A ARX-GVB t A i n y U k BS r o AV t o0g i d- lt4x pur- SRAO 2 Specifications Outdoor Units R-40A ARX-GVB 2- NOMINAL CAPACITY AND NOMINAL INPUT ARX20GVB ARX25GVB ARX5GVB For combination

More information

Split-Sky Air FAYP-B Wall Mounted Unit

Split-Sky Air FAYP-B Wall Mounted Unit TECHNICAL DATA Split-Sky Air FAYP-B Wall Mounted Unit Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential

More information

technical data Systems FXMQ-MVE Conceiled ceiling unit (large)

technical data Systems FXMQ-MVE Conceiled ceiling unit (large) technical data Systems FXMQ-MVE Conceiled ceiling unit (large) FXMQ-MVE 11 Concealed ceiling unit (large) 11 1 Features...2 2 Specifications Technical specifications...3 Electrical specifications...4 Safety

More information

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQA3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB TABLE OF CONTENTS FXDQ-A3 1 Features.............................................................

More information

Split-Sky Air FDYP-B7 Concealed Ceiling Unit

Split-Sky Air FDYP-B7 Concealed Ceiling Unit TECHNICAL DATA Split-Sky Air FDYP-B7 Concealed Ceiling Unit Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the

More information

technical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air

technical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air technical data FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette Multi (950mm Split Heat x 950mm) Pump (edited) air conditioning systems Split Sky Air Outdoor Units R40A MXS-DAVMB_E2VB_E7VB Features V i

More information

Fan Coil Units. Technical Data

Fan Coil Units. Technical Data Fan Coil Units Technical Data F a n c o i l u n i t s E E D E N 1 1-4 0 0 Fan Coil Units Technical Data F a n c o i l u n i t s E E D E N 1 1-4 0 0 Table of Contents Table of Contents 3 Round Flow Cassette...

More information

technical data air conditioning systems FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette Split Sky Air

technical data air conditioning systems FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette Split Sky Air technical data FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help

More information

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air technical data RXG-C Wall Mounted, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human

More information

EEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air

EEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air EEDEN08-00 technical data FDQ-B8V3B9 air conditioning systems Split Sky Air Split - Sky Air Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led

More information

technical data air conditioning systems MXS-B Multi Application Split Sky Air

technical data air conditioning systems MXS-B Multi Application Split Sky Air technical data MXS-B Multi Application air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment

More information

technical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air technical data RKS-C RKS-B Pair Application, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help

More information

Air Conditioners. Technical Data. Individual branch selector for VRV heat recovery (Individual BS box) EEDEN BSVQ P8

Air Conditioners. Technical Data. Individual branch selector for VRV heat recovery (Individual BS box) EEDEN BSVQ P8 Air Conditioners Technical Data Individual branch selector for VRV heat recovery (Individual BS box) EEDEN11-200 BSVQ100-250P8 Air Conditioners Technical Data Individual branch selector for VRV heat recovery

More information

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series Inverter cooling only / heat pump series RSX(Y)P5,8,10K7W1 RSX(Y)P-K7W1 1 Inverter cooling only / heat pump series 1 1 Specifications

More information

technical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air

technical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air technical data MA-GZ7 Multi Model Application air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect human health

More information

Split-Sky Air RMX-JZ Super Multi Plus

Split-Sky Air RMX-JZ Super Multi Plus TECHNICAL DATA Split-Sky Air RMX-JZ Super Multi Plus Split Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment from the potential

More information

1 Features. Outdoor Units R-410A RZQ71-140C7V1B. Split Sky Air Outdoor Units

1 Features. Outdoor Units R-410A RZQ71-140C7V1B. Split Sky Air Outdoor Units i r -t i l t - Outdoor Units R-40A RZQ7-40C7VB Features V 7n y CU k 0 S 4 oa o 0 d 7 4Q puz RO S Outdoor units for pair, twin, triple, double twin application The Sky Air Inverter is developed for use

More information

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-GV

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-GV Air Conditioning Technical Data Wall mounted unit EEDEN15-100 FTX-GV TABLE OF CONTENTS FTX-GV 1 Features............................................................. 2 2 Specifications.......................................................

More information

technical data air conditioning systems RQ-B7 Pair/Twin/Triple/Double Twin Application Split Sky Air

technical data air conditioning systems RQ-B7 Pair/Twin/Triple/Double Twin Application Split Sky Air technical data RQ-B7 Pair/Twin/Triple/Double Twin Application air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help protect

More information

High Wall Type ( 2 Series )

High Wall Type ( 2 Series ) Jan.05' Engineering Data High Wall Type ( 2 Series ) Indoor Unit MMK-AP0072H MMK-AP0092H MMK-AP0122H 1. Equipments 2. Technical Specifications 3. Dimensional Drawing 4. Wiring Diagram 5. Refrigerant Cycle

More information

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

V33B High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven

More information

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4

More information

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams... MCAC-VTSM-2013-08 1. Features... 264 2. Specifications... 265 3. Dimensions... 268 4. Service Spaces... 272 5. Piping Diagrams... 273 6. Wiring Diagrams... 274 7. Capacity Tables... 276 8. Electrical Characteristics...

More information

Air Conditioning. Technical Data. Heat reclaim ventilation EEDEN VAM-FA/FB

Air Conditioning. Technical Data. Heat reclaim ventilation EEDEN VAM-FA/FB Air Conditioning Technical Data Heat reclaim ventilation EEDEN14-205 VAM-FA/FB Heat reclaim ventilation VAM-FA/FB VAM-FA/FB 1 Features............................................................. 2 2 Specifications.......................................................

More information

Service manual MIV V4+ Indoor units

Service manual MIV V4+ Indoor units Service manual MIV V4+ Indoor units Floor Standing MVF22A-VA1 MVF28A-VA1 MVF36A-VA1 MV5A-VA1 MVF56A-VA1 MVF71A-VA1 MVF80A-VA1 MVB22A-VA1 MVB28A-VA1 MVB36A-VA1 MVB45A-VA1 MVB56A-VA1 MVB71A-VA1 MVB80A-VA1

More information

Compact Four-way Cassette Type

Compact Four-way Cassette Type 1. Features... 34 2. Specifications... 35 3. Dimensions... 37 4. Service Spaces... 38 5. Piping Diagrams (EXV beside)... 39 6. Wiring Diagrams... 40 7. Capacity Tables... 41 8. Electrical Characteristics...

More information

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, standard or high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has

More information

Technical Service Manual

Technical Service Manual Technical Service Manual 60 Hz Low/Mid Pressure Duct Units 7 48 MBH Units 96 MBH Unit June 2009 VRF-SVM21A-EN Low and Mid Pressure Duct Units 1. Features......... 2 2. Specifications......... 3 3. Dimensions.........

More information

technical data air conditioning systems RYP-L7/B7 Pair Application Split Sky Air

technical data air conditioning systems RYP-L7/B7 Pair Application Split Sky Air technical data RYP-L7/B7 Pair Application air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the

More information

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Indoor Console Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Black Display Functional art, the touch screen display is elegant

More information

Split. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B

Split. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B Split Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B Indoor Unit FTXC-A TABLE OF CONTENTS FTXC-A 1 Features.............................................................

More information

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit E10-1 High Static Duct 8, 10HP Digital Inverter Engineering Data Book Indoor Unit RAV-SM2242DT-E RAV-SM2802DT-E RAV-SM2242DT-TR RAV-SM2802DT-TR Outdoor Unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents 1 Specifications..............................................................

More information

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 2015 1. Features...2 2. Specifications...3 3. Dimensions...7 4.Service Spaces...8 5.Piping

More information

Low Static Pressure Duct(V shape evaporator)

Low Static Pressure Duct(V shape evaporator) Low Static Pressure Duct (V shape evaporator) 1. Features... 116 2. Specifications... 118 3. Dimensions... 121 4. Service Spaces... 123 5. Piping Diagrams... 124 7.Fan Performance... 126 8.Capacity Tables...

More information

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1

More information

Digital Inverter 4 series

Digital Inverter 4 series TCTC-E14-LC005-2 Digital Inverter 4 series Outdoor Unit RAV-SM304ATP-E RAV-SM304ATJP-E RAV-SM4ATP-E RAV-SM4ATJP-E I ndoor Unit RAV-SM307KRTP-E RAV-SM7KRTP-E RAV-SM7CTP-E RAV-SM304MUT-E RAV-SM4MUT-E RAV-SM304SDT-E

More information

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit E0--2 High Static Duct 8, 0HP Digital Inverter Engineering Data Book Indoor Unit RAV-SM2242DT-E RAV-SM2802DT-E RAV-SM2242DT-TR RAV-SM2802DT-TR Outdoor Unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents Specifications..............................................................

More information

Heating Nom. dba Cooling Nom. dba Night quiet mode Level 1 dba Item Tie-wraps Tie-wraps Tie-wraps Tie-wraps

Heating Nom. dba Cooling Nom. dba Night quiet mode Level 1 dba Item Tie-wraps Tie-wraps Tie-wraps Tie-wraps RZQG71L8Y1B RZQG100L8Y1B RZQG125L8Y1B RZQG140L7Y1B Sound pressure level Heating Nom. dba 50 52 53 53 Cooling Nom. dba 48 50 51 52 Night quiet mode Level 1 dba 43 45 45 45 Standard Accessories Item Tie-wraps

More information

Vertical Air Handling Unit type

Vertical Air Handling Unit type Vertical Air Handling Unit type Engineering Databook MMD-AP0120VHG2UL MMD-AP0180VHG2UL MMD-AP0240VHG2UL MMD-AP0300VHG2UL MMD-AP0360VHG2UL MMD-AP0420VHG2UL MMD-AP0480VHG2UL MMD-AP0600VHG2UL Contents 1.

More information

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDA Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Slim, compact design for limited space requirements. Installs out of sight between the

More information

Low Static Pressure Duct (V shape evaporator)

Low Static Pressure Duct (V shape evaporator) MCAC-VTSM-2015-04 Low Static Pressure Duct Type Low Static Pressure Duct (V shape evaporator) 1. Features... 100 2. Specifications... 101 3. Dimensions... 105 4.Service Spaces... 106 5.Piping Diagrams...

More information

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ Bulletin No. 210712 March 2018 Low-sound, three-speed Wall Mount with LED display offers three

More information

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series VRF Indoor Unit 50Hz Type: Wall Mounted M Series Wall Mounted S Series Contents 01 Wall Mounted M Series 20 Wall Mounted S Series MCAC-VTSM-2016-05 Wall Mounted M Series Wall Mounted M Series 1. Features...

More information

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDB Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Bulletin No. 210711 March 2018 Slim, compact design for limited space requirements. Installs

More information

SINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU)

SINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU) SINGLE Technical Data Book 4Way Cassette S for Nordic (R4A, 5Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU) History Version Modification Date Remark Ver.1. Released SINGLE for Nordic TDB 15.3.. Ver.1.1

More information

19 Series. High-Efficiency Wall-Mounted Ductless systems. Performance: Up to 19 SEER 12.5 EER 9.0 HSPF. Product Features

19 Series. High-Efficiency Wall-Mounted Ductless systems. Performance: Up to 19 SEER 12.5 EER 9.0 HSPF. Product Features 19 Series High-Efficiency Wall-Mounted Ductless systems Performance: Up to 19 SEER 12.5 EER 9.0 HSPF Product Features Inverter Compressor 208/230/1 Power Supply Cooling Range: -4-115 F (with optional wind

More information

Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2

Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2 2-8 GENERAL DATA 2.3. INVERTER SERIES 2.3.1. INVERTER (RAS-25YHA2/35YHA3/50YHA2/60YHA2/70YHA2/80YHA2) Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2 Power Supply From Outdoor Unit

More information

VRF. Technical Data Book. Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH***

VRF. Technical Data Book. Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH*** VRF Technical Data Book Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH*** History Version Modification Date Remark Ver.1.0 Release Ceiling for America (R410A, 60Hz, HP) 15.11.04 - 1 Nomenclature

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E R407C TECHNICAL MANUAL Split Systems Air Conditioner Ducted Blower D & E Series FDMP-D, FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E series Cooling only & Heatpump [50Hz] Table of Contents Table of Contents

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2012.10 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics

More information

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz] R22 TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E Cooling only & Heatpump [50Hz] Table of Contents Table of Contents Nomenclature...1 Indoor...1

More information

VHIA High-Static Ducted Indoor Units - 60HZ

VHIA High-Static Ducted Indoor Units - 60HZ PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage

More information

VRF. Technical Data Book. DVM Indoor Unit PAC for Global (INV, R410A, HP) Model : AM140JNPDKH/TK (50/60Hz) AM280JNPDKH/TK (50Hz)

VRF. Technical Data Book. DVM Indoor Unit PAC for Global (INV, R410A, HP) Model : AM140JNPDKH/TK (50/60Hz) AM280JNPDKH/TK (50Hz) VRF Technical Data Book DVM Indoor Unit PAC for Global (INV, R410A, HP) Model : AM140JNPDKH/TK (50/60Hz) AM280JNPDKH/TK (50Hz) History Version Modification Date Remark Ver.1.0 Release DVM Indoor PAC for

More information

Fan coil units. Why choose Daikin fan coil units? 540 Products overview 542. Options & accessories 560. Round flow cassette 544 FWC-BT/BF 544

Fan coil units. Why choose Daikin fan coil units? 540 Products overview 542. Options & accessories 560. Round flow cassette 544 FWC-BT/BF 544 Fan coil units Why choose Daikin fan coil units? 540 Products overview 542 Round flow cassette 544 FWC-BT/BF 544 4-way blow ceiling mounted cassettes 545 FWG-AT/AF 545 FWF-BT/BF 546 FWF-CT 547 Floor standing

More information

Version Modification Date Remark

Version Modification Date Remark Version Modification Date Remark Products 1 Nomenclature... 2 Line-up... 3 Accessory... 1 Nomenclature 1-1. Nomenclature Model name AM RVX 45 1 HF TN T4 FD EE EH / EU 1 (Buyer) Classification AM DVM

More information

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE TECHNICAL SELECTION DATA SPLIT DUCTED UNIT 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE AXIAL UNIT FEATURES Scroll Compressor Multiple Speed Outdoor Fans Louvred Outdoor Coil Guard Pre-charged with

More information

Four-way Cassette Type

Four-way Cassette Type Four-way Cassette Type Four-way Cassette Type 1. Features... 9 2. Specifications... 12 3. Dimensions... 17 4. Service Space... 18 5. Wiring Diagrams... 19 6. Capacity Tables... 21 7. Electric Characteristics...

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2013.12 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics

More information

Fan Coil Units. Technical Data ECDEN FWL-DT/DF

Fan Coil Units. Technical Data ECDEN FWL-DT/DF Fan Coil Units Technical Data ECDEN10-400 FWL-DT/DF Fan Coil Units Technical Data ECDEN10-400 FWL-DT/DF TABLE OF CONTENTS FWL-DT/DF 1 Features.............................................................

More information

SERVICE MANUAL MU-A09YV - E1 MU-A09YV - MU-A12YV - E1 HFC. Wireless type Models SPLIT-TYPE, AIR CONDITIONERS. No. OB330 R410A CONTENTS.

SERVICE MANUAL MU-A09YV - E1 MU-A09YV - MU-A12YV - E1 HFC. Wireless type Models SPLIT-TYPE, AIR CONDITIONERS. No. OB330 R410A CONTENTS. SPLIT-TYPE, AIR CONDITIONERS Revision A: MU-A2YV - E can be connected to MCF-A2WV - E. Please void OB330. SERVICE MANUAL Wireless type Models E MU-A07YV - E MU-A09YV - MU-A2YV - E HFC utilized R40A No.

More information

PRK PREVIEW. System. OZONE FRIENDLY R-407C Series. Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump)

PRK PREVIEW. System. OZONE FRIENDLY R-407C Series. Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump) PRK 00-04 PREVIEW System OZONE FRIENDLY R-407C Series Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump) 3DUW#4 2XWGRRU#8QLWV 111111111111111111111111111111111111111111111111111111111111111111111

More information

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered

More information

Air Conditioning Technical Data RZQG-L(8)Y1

Air Conditioning Technical Data RZQG-L(8)Y1 Air Conditioning Technical Data RZQG-L(8)Y TABLE OF CONTENTS RZQG-L(8)Y Features............................................................. 2 2 Specifications.......................................................

More information

SINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU

SINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU SINGLE Technical Data Book Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU History Version Modification Date Remark Ver.1.0 Release SINGLE Big

More information

SERVICE MANUAL OUTDOOR UNIT. No. OB387

SERVICE MANUAL OUTDOOR UNIT. No. OB387 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS Revision C: MUH-A25VB - E has been added. Please void OB87 REVISED EDITION-B. OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A. OB87 REVISED EDITION-C Wireless type

More information

Air Conditioning Technical Data RZQSG-L3/9V1

Air Conditioning Technical Data RZQSG-L3/9V1 Air Conditioning Technical Data RZQSG-L/9V1 Outdoor Unit RZQSG-L/9V1 TABLE OF CONTENTS RZQSG-L/9V1 1 Features............................................................. 2 2 Specifications.......................................................

More information

MSP Duct S Specifications

MSP Duct S Specifications MSP Duct S Specifications Model Name AM022FNMDEH AM028FNMDEH AM036HNMPKH AM045HNMPKH AM056HNMPKH Capacity *2) 2.2 2.8 3.6 4.5 5.6 *3) 2.5 3.2 4.0 5.0 6.3 Perfomance (Total) *5) kw 1.8 2.3 2.9 3.7 4.6 VRF

More information

Split-Sky Air RP-B7 Twin/Triple/Double Twin Application

Split-Sky Air RP-B7 Twin/Triple/Double Twin Application TECHNICAL DATA Split-Sky Air RP-B7 Twin/Triple/Double Twin Application Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment

More information

Air Conditioners. Technical Data. VRV III heat recovery, with connection to heating only hydrobox REYAQ-P

Air Conditioners. Technical Data. VRV III heat recovery, with connection to heating only hydrobox REYAQ-P Air Conditioners Technical Data VRV III heat recovery, with connection to heating only hydrobox E E D E N 1 1-2 0 0 REYAQ-P Air Conditioners Technical Data VRV III heat recovery, with connection to heating

More information

VRF. Technical Data Book. DVM IDU_Vertical AHU for NA (R410A, 60Hz, HP) Model : AM***JNZDCH/AA

VRF. Technical Data Book. DVM IDU_Vertical AHU for NA (R410A, 60Hz, HP) Model : AM***JNZDCH/AA VRF Technical Data Book DVM IDU_ for NA (R4A, 6Hz, HP) Model : AM***JNZDCH/AA Version Modification Date Remark Ver.. Release DVM Indoor Unit_ TDB for America 5. 6.. Ver.. Modification for Heater kit (option)

More information

/ LOSSNAY / LGH-RS2-E2

/ LOSSNAY / LGH-RS2-E2 2 Indoor units / / LGH-RS2-E2 unit CONTENTS LGH-RS2-E2. LGH-5RS2-E2 48 2. LGH-25RS2-E2 49. LGH-5RS2-E2 44 4. LGH-5RS2-E2 44 5. LGH-8RS2-E2 442 6. LGH-RS2-E2 7. LGH-5RS2-E2 8. LGH-2RS2-E2 44 444 445 9.

More information

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature

More information

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES

More information

CENTRIFUGAL FAN COIL UNIT VCE

CENTRIFUGAL FAN COIL UNIT VCE CENTRIFUGAL FAN COIL UNIT VCE 0,51 kw 11,00 kw 0,85 kw 23,75 kw 129 m 3 /h 2003 m 3 /h VCE DESIGN QUALITY COMFORTRELIABILITY 3VERSION12 SIZE DESIGN VCEx0 vertical with cabinet Air intake: bottom vertical

More information

SINGLE Technical Data Book. SINGLE for Europe (R410A, HP)

SINGLE Technical Data Book. SINGLE for Europe (R410A, HP) SINGLE Technical Data Book SINGLE for Europe (R410A, HP) History Ver.1.0 Release Single TDB for Europe 16. 11. 02 Ver.1.1 Add tco2e data (Specifications) 16. 12. 09 Ver.1. 1.. 09 2 CAC - World-class energy

More information

FFQN-C, FCRN-E, FFRN-C

FFQN-C, FCRN-E, FFRN-C R410A TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FCQN-E, FFQN-C, FCRN-E, FFRN-C Cooling only & Heatpump [50Hz] DAIKIN_FFRN.indb i 12/27/2012 9:28:06 AM DAIKIN_FFRN.indb ii

More information

SERVICE MANUAL OUTDOOR UNIT. No. OB386

SERVICE MANUAL OUTDOOR UNIT. No. OB386 SPLIT-TYPE AIR CONDITIONERS Revision D: MU-A20VB- E and MU-A5VB- E have been added. Please void OB86 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A No. OB86 REVISED EDITION-D Models MU-A20VB-

More information

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system

More information

SERVICE MANUAL MU-GA20VB- MU-GA20VB- MU-GA25VB- MU-GA25VB- MU-GA35VB- E1 OUTDOOR UNIT. No. OB386. Wireless type Models HFC

SERVICE MANUAL MU-GA20VB- MU-GA20VB- MU-GA25VB- MU-GA25VB- MU-GA35VB- E1 OUTDOOR UNIT. No. OB386. Wireless type Models HFC SPLIT-TYPE, AIR CONDITIONERS Revision B: MU-A20VB- E2 and MU-A25VB - have been added. Please void OB86 REVISED EDITION-A. E2 OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A No. OB86 REVISED EDITION-B Wireless

More information

DVM. Technical Data Book

DVM. Technical Data Book DVM Technical Data Book Outdoor Units I. Products 1 2 3 Outdoor units Indoor units Accessories 6 7 9 2 II. Outdoor units 1 2 3 4 5 6 Specifications Operation limit Electrical wiring diagram Sound level

More information

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CV3

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CV3 Heating Technical Data Daikin Altherma low temperature split EEDEN2-725 ERLQ-CV Daikin Altherma low temperature split ERLQ-CV TABLE OF CONTENTS ERLQ-CV Features.............................................................

More information

Version Modification Date Remark

Version Modification Date Remark Version Modification Date Remark Index 1 Nomenclature 2 Specifications 3 Capacity table 4 Dimensional drawing 5 Electrical wiring diagram 6 Sound pressure level 7 Temperature and air flow distribution

More information

A2P H2P H4P H6P H1P H3P H5P H7P. Outdoor X205A OFF Y1E E1H R6T X5A F8U F7U K14R K2R X28A X6A SEE NOTE 7 HAP X77A X31A X13A X21A P< S1PL P> S1PH

A2P H2P H4P H6P H1P H3P H5P H7P. Outdoor X205A OFF Y1E E1H R6T X5A F8U F7U K14R K2R X28A X6A SEE NOTE 7 HAP X77A X31A X13A X21A P< S1PL P> S1PH RZQSG00L9V N L N 50Hz 0-40V Z5 GRN D089497B WHT HR BRNHR3 PPLHR4 HR + E K0R V3D L N LA FU FU ZF ZF KM Z GRN/YLW Z 5 NA VT VT VD + R VR FU V Z3F Z4 X0A WHT X50A 4 MF MS M3 MS ~ Position of compressor terminal

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

Fan Coil Units. Technical Data. Conceiled ceiling unit ECDEN FWB-BT

Fan Coil Units. Technical Data. Conceiled ceiling unit ECDEN FWB-BT Fan Coil Units Technical Data Conceiled ceiling unit ECDEN10-400 FWB-BT Fan Coil Units Technical Data Conceiled ceiling unit ECDEN10-400 FWB-BT TABLE OF CONTENTS FWB-BT 1 Features.............................................................

More information

SERVICE MANUAL MUH-GA20VB- MUH-GA20VB- MUH-GA25VB- MUH-GA25VB- MUH-GA35VB- E1 OUTDOOR UNIT. No. OB387. Wireless type Models HFC

SERVICE MANUAL MUH-GA20VB- MUH-GA20VB- MUH-GA25VB- MUH-GA25VB- MUH-GA35VB- E1 OUTDOOR UNIT. No. OB387. Wireless type Models HFC SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS Revision A: MUH-A20VB- E2 and MUH-A25VB - have been added. Please void OB87. E2 OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A. OB87 REVISED EDITION-A Wireless type

More information

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL Centrifugal fan coil units SYSCOIL Fan coil units Compact, slim fan coil units. Available

More information

M1 TYPE SLIM VARIABLE STATIC PRESSURE HIDE AWAY CONCEALED DUCT

M1 TYPE SLIM VARIABLE STATIC PRESSURE HIDE AWAY CONCEALED DUCT VRF SYSTEMS M TYPE SIM VARIABE STATIC PRESSURE IDE AWAY CONCEAED DUCT The ultra slim M type is one of the leading products of its type in the industry. With a depth of only mm it provides greater flexibility

More information

CHILLED WATER FAN-COIL UNITS

CHILLED WATER FAN-COIL UNITS 40LM - PRODUCT DATA DIGEST CHILLED WATER FAN-COIL UNITS QUALITY SYSTEM MALAYSIA MS ISO 001 REG. NO: AR 023 1 Any room, every room flexibility in an air conditioning system FEATURES: Chilled Water Furred-in

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

HCH6. Product Specifications

HCH6. Product Specifications HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

CEILING CONCEALED LOSSNAY LGH-25RX3

CEILING CONCEALED LOSSNAY LGH-25RX3 VOLUME SIGN Control signal Heat recovery system Heat recovery module material Cladding Heat insulating material Motor Blower Filter material Operating environment (Supply air) Functions Weight Serial single

More information

SERVICE MANUAL MUH-GA25VB - E1 MUH-GA25VB - MUH-GA35VB - E1 HFC. Wireless type Models SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No. OB387 R410A CONTENTS

SERVICE MANUAL MUH-GA25VB - E1 MUH-GA25VB - MUH-GA35VB - E1 HFC. Wireless type Models SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No. OB387 R410A CONTENTS SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS SERVICE MANUAL Wireless type Models E MUH-GA20VB - E MUH-GA25VB - MUH-GA35VB - E HFC utilized R40A. OB387 CONTENTS Indication of model name MUH-GA20VB - E MUH-GA25VB

More information

SINGLE. Technical Data Book. Big Ceiling for Europe (R410A, 50Hz, H/P)

SINGLE. Technical Data Book. Big Ceiling for Europe (R410A, 50Hz, H/P) SINGLE Technical Data Book Big Ceiling for Europe (R4A, Hz, H/P) Version Modification Date Remark Ver.1. Release SINGLE Big Ceiling for Europe (R4A, Hz, H/P) TDB 1.4.3 Ver.1.1 Modification for drain pipe

More information