1 Progressive Innovative Solutions HPS Imperator Encapsulated Machine Tool Industrial Control Transformers Lifetime Warranty Unique Terminal Block Innovative Fusing Method Patented Design
2 HPS Imperator Control Transformer Our Company Hammond Power Solutions (HPS) was established in 9 in Guelph, Ontario and has grown from a small family owned business in the short wave radio market, to the industry leader in magnetic transformer design and manufacturing. HPS has manufacturing facilities and currently has 0 regional distribution centers throughout North America. Innovative Design The HPS Imperator series is a unique innovative and compact design that provides the ideal solution for any industrial control application and will change the way the industrial machine tool industry looks at the control transformer. The HPS Imperator s unique terminal block design allows for the quick and easy installation of standard secondary or optional primary / x / midget/type CC fuse clips on every unit. This is the simplest and most inexpensive fusing installation provided on any industrial control transformer in the market today. The windings and internal terminations of the HPS Imperator are encapsulated which protects them from moisture, dirt and other airborne contaminants. The custom molded coil covers their unique fin shaped design combine superior transformer cooling properties a clean bold look. The HPS Imperator utilizes custom serrated terminals, in combination standard SEMS washer screws making assembly easier and quicker to install; and provides superior connection strength when connecting bare, solid or stranded wire. It also allows for ring or spade termination connectors. The Perfect Solution The HPS Imperator series of machine tool rated industrial control transformers are specifically designed to meet the high inrush industrial applications where electromagnetic components such as relays, solenoids and magnetic motor starters are used. With standard voltage groups, a VA range from 0VA to 00VA and available standard secondary and optional primary fuse kits, the HPS Imperator series provides the perfect solution for any application. Engineering Precision Visit our website:
3 Applications Automation Panel Shops Machines Panel Boards Solenoids Control Applications Timers Performance Value Quality Industries Superior Quality & Value Paper Mills Printing Automotive Packaging Systems The HPS Imperator series design, utilizing superior insulation systems and being constructed high quality silicon steel laminations for optimum performance, will meet or exceed UL and CE standards. Backed by an industry leading LIFETIME warranty, the HPS Imperator industrial control transformer line offers superior performance, quality and value. Process Automation
4 Features & Benefits 00V class, machine tool rated industrial control transformers standard multi primary and secondary voltage groups available 0/0 Hertz (0Hz on PH***AJ & PH***AR) VA range from 0 up to 00 Superior insulation system 0-0VA, temperature rise C, insulation class 0 C 0-00VA, temperature rise 0 C, insulation class 0 C Constructed high quality silicon steel laminations that provide optimum performance and reliability Encapsulated coils encased in a custom injection molded cover, protect coils and terminations from moisture, dirt and other industrial airborne contaminants. Feet: made of heavy steel and welded or bolted to the core, these mounting feet provide superior strength in a compact design. Termination: combination slot/philips # screw, complete SEMS washer (suitable for AWG to AWG solid or AWG stranded wire) Standard SEMS washers - supplied on all units Standard secondary fuse kits -utilizing / x / midget/type CC fuse clips (supplied all units) Optional primary fuse kits available utilizing / x / midget/type CC fuse clips Optional finger safe terminal covers available on all units UL Listed (approved for U.S. and Canada) CE Mark standard on all units (excluding PH***AJ & PH***AR) LIFETIME Warranty (Limited) RoHS Compliant special voltages and VA sizes available upon request excluding PH0PG, PH000PG, PH0MLI, PH000MLI Warranty Lifetime
5 Terminal connection numbers molded into terminal block and correspond to nameplate and wiring diagrams, make connecting the HPS Imperator quick and simple. Innovative terminal block design provides for easy hook-up and installation of fuse clips. SEMS washer allows for easy connection of supply or load wires or out terminal connectors Standard secondary and optional primary fuse kits utilizing / x / midget/type CC fuse clips provide an economical solution to your fusing requirements (fuses not available). Optional removable finger safe terminal covers available on all standard units. Custom injection molded coil cover its unique fin shaped design combine superior cooling properties a clean, bold look. Made of heavy steel and welded or bolted to the core, these mounting feet provide superior strength in a compact design.
6 Group A Primary Voltage: 00 0 Secondary Voltage: 0 x 0 x 0 0 x 0 0 Hertz VA Rating Catalog Mtg. Fig. Output Amps Overall Dimensions Centers Slot A B C D E G X H Height Depth Approx. Ship Weight Lbs. Optional Primary Fuse Kit P/N 0 PH0AJ A 0./ x PFK PHAJ A 0./ x PFK 00 PH00AJ A 0./ x PFK 0 PH0AJ B./ x PFK 0 PH0AJ B.0/ x PFK 0 PH0AJ B.9/ x PFK 00 PH00AJ B./ x PFK 0 PH0AJ B./ x PFK 000 PH000AJ B./ x PFK 00 PH00AJ B./ x PFK Secondary fuse clips, fuse clip mounting screws and primary and secondary voltage links/jumpers supplied standard transformers. Please refer to page for dimensional drawings. Special voltages and VA sizes available upon request. All dimensions in inches Group B Primary Voltage: 00 0 Secondary Voltage: x. x x 0 Hertz VA Rating Catalog Mtg. Fig. Output Amps Overall Dimensions Centers Slot A B C D E G X H Height Depth Approx. Ship Weight Lbs. Optional Primary Fuse Kit P/N 0 PH0AR A./ x PFK PHAR A./ x PFK 00 PH00AR A./ x PFK 0 PH0AR B./ x PFK 0 PH0AR B 0./ x PFK 0 PH0AR B 9./ x PFK 00 PH00AR B./ x PFK Secondary fuse clips, fuse clip mounting screws and primary and secondary voltage links/jumpers supplied transformers. Please refer to page for dimensional drawings. Special voltages and VA sizes available upon request. All dimensions in inches Visit our website:
7 Group C Primary Voltage: 0 x 0 0 x 0 0 x 0 Secondary Voltage: 0 x 0 x 0 0 x 0 0/0 Hertz VA Rating Catalog Mtg. Fig. Output Amps Overall Dimensions Centers Slot A B C D E G X H Height Depth Approx. Ship Weight Lbs. Optional Primary Fuse Kit P/N 0 PH0MQMJ A 0./ x PFK PHMQMJ A 0./ x PFK 00 PH00MQMJ A 0./ x PFK 0 PH0MQMJ B./ x PFK 0 PH0MQMJ B.0/ x PFK 0 PH0MQMJ B.9/ x PFK 00 PH00MQMJ B./ x PFK 0 PH0MQMJ B./ x PFK 000 PH000MQMJ B./ x PFK 00 PH00MQMJ B./ x PFK Secondary fuse clips, fuse clip mounting screws and primary and secondary voltage links/jumpers supplied standard transformers. Please refer to page for dimensional drawings. Special voltages and VA sizes available upon request. All dimensions in inches Group D Primary Voltage: 0 x 0 0 x 0 0 x 0 Secondary Voltage: x. x x 0/0 Hertz VA Rating Catalog Mtg. Fig. Output Amps Overall Dimensions Centers Slot A B C D E G X H Height Depth Approx. Ship Weight Lbs. Optional Primary Fuse Kit P/N 0 PH0QR A./ x PFK PHQR A./ x PFK 00 PH00QR A./ x PFK 0 PH0QR B./ x PFK 0 PH0QR B 0./ x PFK 0 PH0QR B 9./ x PFK 00 PH00QR B./ x PFK Secondary fuse clips, fuse clip mounting screws and primary and secondary voltage links/jumpers supplied standard transformers. Please refer to page for dimensional drawings. Special voltages and VA sizes available upon request. All dimensions in inches
8 Group E Primary Voltage: 0 x 00 x x 0 Secondary Voltage: 0 x 0 x 0 0 x 0 0/0 Hertz VA Rating VA Rating Catalog Catalog Mtg. Fig. Mtg. Fig. Output Amps Output Amps Overall Dimensions Overall Dimensions Centers Centers Slot A B C D E G X H Mtg. Slot A B C D E G X H Height Height Depth Depth Approx. Ship Weight Lbs. Primary Voltage: 0 x 0 x 0 0 x 0 Secondary Voltage: 0 x 0 x 0 0 x 0 0/0 Hertz Approx. Ship Weight Lbs. Optional Primary Fuse Kit P/N 0 PH0SP A 0./ x PFK PHSP A 0./ x PFK 00 PH00SP A 0./ x PFK 0 PH0SP B./ x PFK 0 PH0SP B.0/ x PFK 0 PH0SP B.9/ x PFK 00 PH00SP B./ x PFK 0 PH0SP B./ x PFK 000 PH000SP B./ x PFK Secondary fuse clips, fuse clip mounting screws and primary and secondary voltage links/jumpers supplied standard transformers. Please refer to page for dimensional drawings. Special voltages and VA sizes available upon request. Group F Optional Primary Fuse Kit P/N 0 PH0PP A 0./ x PFK PHPP A 0./ x PFK 00 PH00PP A 0./ x PFK 0 PH0PP B./ x PFK 0 PH0PP B.0/ x PFK 0 PH0PP B.9/ x PFK 00 PH00PP B./ x PFK 0 PH0PP B./ x PFK 000 PH000PP B./ x PFK 00 PH00PP B./ x PFK Secondary fuse clips, fuse clip mounting screws and primary and secondary voltage links/jumpers supplied standard transformers. Please refer to page for dimensional drawings. Special voltages and VA sizes available upon request. All dimensions in inches All dimensions in inches Visit our website:
9 Group G Primary Voltage: 0 x 0 x 0 0 x 0 Secondary Voltage: x. x x 0/0 Hertz VA Rating Catalog Mtg. Fig. Output Amps Overall Dimensions Centers Slot A B C D E G X H Height Depth Approx. Ship Weight Lbs. Optional Primary Fuse Kit P/N 0 PH0PG A./ x PFK PHPG A./ x PFK 00 PH00PG A./ x PFK 0 PH0PG B./ x PFK 0 PH0PG B 0./ x PFK 0 PH0PG B 9./ x PFK 00 PH00PG B./ x PFK 0 PH0PG C./ x PFK 000 PH000PG C./ x PFK Secondary fuse clips and fuse clip mounting screws supplied standard transformers up to and including 00VA. Primary and secondary voltage links/jumpers supplied standard transformers. Please refer to page for dimensional drawings. Special voltages and VA sizes available upon request. Group H Primary Voltage: 00/0/0 /0/0 0/0/0 Secondary Voltage: 0/00 /9 0/90 0/0 Hertz VA Rating Catalog Mtg. Fig. Output Amps Overall Dimensions Centers Slot A B C D E G X H Height Depth Approx. Ship Weight Lbs. Optional Primary Fuse Kit P/N 0 PH0MBMH A x PFK PHMBMH A x PFK 00 PH00MBMH B x PFK 0 PH0MBMH B x PFK 0 PH0MBMH B x PFK 0 PH0MBMH B x PFK 00 PH00MBMH B x PFK 0 PH0MBMH B x PFK 000 PH000MBMH B x PFK 00 PH00MBMH B x PFK Secondary fuse clips, fuse clip mounting screws and primary and secondary voltage links/jumpers supplied standard transformers. Please refer to page for dimensional drawings. Special voltages and VA sizes available upon request. All dimensions in inches All dimensions in inches
10 Group I Primary Voltage: 0/0 0/0/0 0/0/00 Secondary Voltage: 0/ / 0/ 0/0 Hertz VA Rating VA Rating Catalog Catalog Mtg. Fig. Mtg. Fig. Output Amps Output Amps Overall Dimensions Overall Dimensions Centers Centers Slot A B C D E G X H Slot A B C D E G X H Height Height Depth Depth Approx. Ship Weight Lbs.s Primary Voltage: /00/0 Secondary Voltage: 0 x 0 0/0 Hertz Approx. Ship Weight Lbs. Optional Primary Fuse Kit P/N 0 PH0MLI A 0./ x PFK PHMLI A 0./ x PFK 00 PH00MLI A 0./ x PFK 0 PH0MLI B.0/ x PFK 0 PH0MLI B./ x PFK 0 PH0MLI B.0/ x PFK 00 PH00MLI B./ x PFK 0 PH0MLI C./ x PFK 000 PH000MLI C.0/ x PFK Secondary fuse clips and fuse clip mounting screws supplied standard transformers up to and including 00VA. Primary and secondary voltage links/jumpers supplied standard transformers. Please refer to page for dimensional drawings. Special voltages and VA sizes available upon request. Group J Optional Primary Fuse Kit P/N 0 PH0MEMX A 0./ x PFK PHMEMX A 0./ x PFK 00 PH00MEMX A 0.9/ x PFK 0 PH0MEMX B./ x PFK 0 PH0MEMX B./ x PFK 0 PH0MEMX B./ x PFK 00 PH00MEMX B./ x PFK 0 PH0MEMX B./ x PFK 000 PH000MEMX B 9.09/ x PFK Secondary fuse clips, fuse clip mounting screws and primary and secondary voltage links/jumpers supplied transformers. Please refer to page for dimensional drawings. Special voltages and VA sizes available upon request. All dimensions in inches All dimensions in inches 9 Visit our website:
11 Group K Primary Voltage: 0//0 Secondary Voltage: 0 x 0 0/0 Hertz VA Rating Catalog Mtg. Fig. Output Amps Overall Dimensions Centers Slot A B C D E G X H Height Depth Approx. Ship Weight Lbs. Optional Primary Fuse Kit P/N 0 PH0MGJ A 0./ x PFK PHMGJ A 0./ x PFK 00 PH00MGJ A 0./ x PFK 0 PH0MGJ B./ x PFK 0 PH0MGJ B.0/ x PFK 0 PH0MGJ B.9/ x PFK 00 PH00MGJ B./ x PFK 0 PH0MGJ B./ x PFK 000 PH000MGJ B./ x PFK Secondary fuse clips, fuse clip mounting screws and primary and secondary voltage links/jumpers supplied transformers. Please refer to page for dimensional drawings. Special voltages and VA sizes available upon request. Accessory Kits Available Kit Part PFK PFK PFK PFK PFK PFK PFK Applicable Transformer Part Suffix s Applicable VA Sizes Parts Included in Kit All dimensions in inches The HPS Imperator series of machine tool rated industrial control transformers are supplied standard secondary fuse kits or optional accessories such as primary fuse kits and finger guards. Standard Secondary Fuse Kits All HPS Imperator control transformers are supplied standard secondary fuse kits which include: / x / midget/type CC fuse clips, fuse clip mounting screws, primary and secondary voltage links and the PHAK instruction sheet (note: secondary fuse clips and fuse clip mounting screws not supplied on the PH0PG, PH000PG, PH0MLI and PH000MLI). Please consult the HPS Transformer Products catalog for additional details. Optional Primary Fuse Kits Refer Refer fuse clips, mtg. screws, PHAK instruction sheet to to fuse clips, mtg. screws, PHAK instruction sheet Specification Specification fuse clips, mtg. screws, PHAK instruction sheet fuse clips, mtg. screws, jumper, finger guard, PHAK instruction sheet Tables Tables fuse clips, mtg. screws, jumper, finger guard, PHAK instruction sheet on Pages on Pages fuse clips, mtg. screws, jumper wire, PHAK instruction sheet to 0 to 0 fuse clips, mtg. screws, jumper wire, PHAK instruction sheet Note: Maximum allowable current rating on all primary and secondary fuse kits is 0 amps. 0
12 Factory Installed Primary and Secondary Fuse Kits HPS now stocks some HPS Imperator series voltage groups FACTORY INSTALLED primary and secondary fuse clips. To order, just add the suffix -FK to the end of the standard part number. Factory installed primary and secondary fuse clips are only available on the following voltage groups: Group C (p/n: PH***MQMJ-FK) Group G (p/n: PH***PG-FK) Group I (p/n: PH***MLI-FK) On PH0PG-FK, PH000PG-FK, PH0MLI-FK, and PH000MLI-FK, only primary fuse clips are included on factory installed units. Secondary fuse clips are not included or available on these units. Note: All factory installed fuse kits are pre-wired at the transformers highest primary voltage and the lowest secondary voltage. To hook up at a different primary or secondary voltage, please refer to the wiring instruction sheet included the transformer. Optional Unfused Kits Kit Part Applicable Transformer Part Suffix s Applicable VA Sizes Parts Included in Kit FG AJ, AR, MQMJ, MEMX, QR, SP, PG, PP 0 finger guard (unfused), PHAK instruction sheet FG MBMH, MGJ, MLI 0 finger guard (unfused), PHAK instruction sheet FG All finger guard (unfused), PHAK instruction sheet FG All (excluding PH00MBMH) 00 finger guard (unfused), PHAK instruction sheet refer to FG, FG or FG below 0 to 00 Optional Fused Kits FGF AJ, AR, MQMJ, MEMX, QR, SP, PG, PP 0 finger guard (fused), PHAK instruction sheet FGF MBMH, MGJ, MLI 0 finger guard (fused), PHAK instruction sheet FGF All finger guard (fused), PHAK instruction sheet FGF All (excluding PH00MBMH) 00 finger guard (fused), PHAK instruction sheet FG MBMH 00 finger guard, PHAK instruction sheet FG All 0 finger guard, PHAK instruction sheet FG AJ, AR, MQMJ, MEMX, QR, SP, PG, PP 0 finger guard, PHAK instruction sheet FG MBMH, MGJ, MLI 0 finger guard, PHAK instruction sheet FG All 0, 00 finger guard, PHAK instruction sheet FG AJ, AR, MQMJ, QR, SP, PP 0 finger guard, PHAK instruction sheet FG MBMH, MEMX, MGJ, MLI, PG 0 finger guard, PHAK instruction sheet FG All 000, 00 finger guard, PHAK instruction sheet Note: Each finger guard kit supplies either the primary or secondary side. Visit our website:
13 Sample Accessory Drawings Voltage Link Fuse Clips (for 0, and 00VA) Fuse Clips (for 0VA to 00VA) Fused & Unfused (for 0, and 00VA) (for 0VA to 00VA) Sample Accessory Assembly Drawings Sample Assembly Drawing for Voltage Link Installation Sample Assembly Drawing for Secondary Fuse Clip Installation (for 0VA to 00VA) Sample Assembly Drawing for Primary Fuse Clip Installation (for 0VA to 00VA) Sample Assembly Drawing for Installation (for 0, and 00VA) Sample Assembly Drawing for Installation (for 0VA to 00VA)
14 Overcurrent Protection Secondary The overcurrent protection listed below, in amperes, is % of the rated current of the transformer. Choose the next higher fuse rating if these numbers do not correspond standard fuse selections. Sec. Voltage VA Rating Primary To assist in the selection of fuses, the following chart recommends the maximum primary fuse rating in amperes. The number shown is the maximum overcurrent protection when the primary current is less than amps and the overcurrent protection device is rated for 00%. Choose the next higher fuse rating if these numbers do not correspond standard fuse selections. Pri. VA Rating Volt Visit our website:
15 Dimensional Drawings Some actual transformer units may differ from dimensional drawings shown below. FIGURE A (00 VA and less) FIGURE B (0 VA to 00 VA) C G x H A D E B FIGURE C (For PH0PG, PH000PG, PH0MLI & PH000MLI)
16 HPS Im p e r at o r Industrial Control Transformer Wiring Diagrams Literature Code: PHWD The HPS Im p e r at o r series of machine tool industrial molded control transformers are available in many standard offerings. This wiring hook-up instruction sheet refers to all standard HPS Im p e r ato r series part number suffixes. (Note: standard secondary fuse kits (not installed) supplied each transformer unless otherwise indicated; field insatlled primary fuse kits sold separately; fuses not available from HPS.) If you have any questions regarding these wiring diagrams or are having any difficulty correctly installing our transformers, please contact HPS customer service or technical support in the U.S. at --0- or in Canada at HPS Im p e r ato r Series - Wiring Schematic Drawings 0V V 0V 0V V 00V 0V 0V 0V PH***AJ Schematic for 0, and 00VA Units High Voltage () Install Supplied Jumpers/ Supply Lines Install Fuse (Primary Volts) Links Between Terminals Connect To Clips To 00 0 None, Unfused 00 0 None, -, - Low Voltage () Install Supplied Links Load Lines Install Fuse 0 0 -, -, Unfused , Unfused 0 0 -, -, , - 0V V 00V PH***AJ Schematic for 0VA to 00VA Units High Voltage () Install Supplied Jumpers/ Supply Lines Install Fuse (Primary Volts) Links Between Terminals Connect To Clips To 00 0 None, Unfused 00 0 None, -, - 0V V 0V 0V 0V 0V Low Voltage () Install Supplied Links Load Lines Install Fuse 0 0 -, -, Unfused , Unfused 0 0 -, -, , - Issue Date: April 009 rev Page of 9
17 HPS Im p e r ato r Series - Wiring Schematic Drawings continued 0V 0V 0V 0V 0V 0V PH***MQMJ Schematic for 0, and 00VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse , -, Unfused , Unfused , -, -, , -, - 0V V 0V 0V 0V 0V Low Voltage () Install Supplied Links Load Lines Install Fuse 0 0 -, -, Unfused , Unfused 0 0 -, -, , - 0V 0V 0V 0V 0V 0V PH***MQMJ Schematic for 0VA to 00VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse , -, Unfused , Unfused , -, -, , -, - 0V V 0V 0V 0V 0V Low Voltage () Install Supplied Links Load Lines Install Fuse 0 0 -, -, Unfused , Unfused 0 0 -, -, , - 0V V 0V 0V 0V 0V PH***PG Schematic for 0, and 00VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse 0 0 -, -, Unfused , Unfused 0 0 -, -, -, , -, - V V.V V V V Low Voltage () Install Supplied Links Load Lines Install Fuse. -, -, Unfused -, Unfused. -, -, - -, - Page of 9
18 HPS Im p e r ato r Series - Wiring Schematic Drawings continued 0V V 0V 0V 0V 0V PH***PG Schematic for 0VA to 00VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse 0 0 -, -, Unfused , Unfused 0 0 -, -, -, , -, - Low Voltage () Install Supplied Links Load Lines Install Fuse V.V V V V V. -, -, Unfused -, Unfused. -, -, - -, - 0V V 0V 0V 0V 0V PH***PG Schematic for 0VA and 000VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse 0 0 -, -, Unfused , Unfused 0 0 -, -, -, , -, - Low Voltage () Install Supplied Links Load Lines Install Fuse V.V V V V V. -, -, Unfused -, Unfused Note: secondary fuse clips not available on PH0PG or PH000PG. Dotted line represents supplied jumper lead* 0V/0V/0V 0V/0V/0V 0V/00V PH***MLI Schematic for 0, and 00VA Units High Voltage () Install Supplied Jumpers Supply Lines Install Fuse None, Unfused None, Unfused 0 00 None, Unfused , -, , -, , -, - 0V/V/0V V/V/V *This primary fuse jumper is supplied the primary fuse kit only. Low Voltage () Install Supplied Jumpers Load Lines Install Fuse 0 0 None, Unfused None, Unfused 0 0 None, - None, - Page of 9
19 HPS Im p e r ato r Series - Wiring Schematic Drawings continued Dotted line represents supplied jumper lead* 0V/0V/0V 0V/0V/0V 0V/00V PH***MLI Schematic for 0VA to 00VA Units High Voltage () Install Supplied Jumpers Supply Lines Install Fuse None, Unfused None, Unfused 0 00 None, Unfused , -, , -, , -, - 0V/V/0V V/V/V *This primary fuse jumper is supplied the primary fuse kit only. Low Voltage () Install Supplied Jumpers Load Lines Install Fuse 0 0 None, Unfused None, Unfused 0 0 None, - None, - Dotted line represents supplied jumper lead* 0V/0V/0V 0V/0V/0V 0V/00V PH***MLI Schematic for 0VA and 000VA Units High Voltage () Install Supplied Jumpers Supply Lines Install Fuse None, Unfused None, Unfused 0 00 None, Unfused , -, , -, , -, - 0V/V/0V V/V/V *This primary fuse jumper is supplied the primary fuse kit only. Low Voltage () Install Supplied Jumpers Load Lines Install Fuse 0 0 None, Unfused None, Unfused Note: secondary fuse clips for V tap not available on the PH0MLI or PH000MLI units. 0V V 00V PH***AR Schematic for 0, and 00VA Units High Voltage () Install Supplied Jumpers/ Supply Lines Install Fuse (Primary Volts) Links Between Terminals Connect To Clips To 00 0 None, Unfused 00 0 None, -, - V V.V V V V Low Voltage () Install Supplied Links Load Lines Install Fuse. -, -, Unfused -, Unfused. -, -, - -, - Page of 9
20 HPS Im p e r ato r Series - Wiring Schematic Drawings continued 0V V 00V PH***AR Schematic for 0VA to 00VA Units High Voltage () Install Supplied Jumpers/ Supply Lines Install Fuse (Primary Volts) Links Between Terminals Connect To Clips To 00 0 None, Unfused 00 0 None, -, - V V.V V V V Low Voltage () Install Supplied Links Load Lines Install Fuse. -, -, Unfused -, Unfused. -, -, - -, - 0V 0V 0V 0V 0V 0V PH***QR Schematic for 0, and 00VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse , -, Unfused , Unfused , -, -, , -, - V V.V V V V Low Voltage () Install Supplied Links Load Lines Install Fuse. -, -, Unfused -, Unfused. -, -, - -, - 0V 0V 0V 0V 0V 0V PH***QR Schematic for 0VA to 00VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse , -, Unfused , Unfused , -, -, , -, - V V.V V V V Low Voltage () Install Supplied Links Load Lines Install Fuse. -, -, Unfused -, Unfused. -, -, - -, - Page of 9
21 HPS Im p e r ato r Series - Wiring Schematic Drawings continued 90V 00V 0V 0V 00V V PH***SP Schematic for 0, and 00VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse , -, Unfused , Unfused , -, -, , -, - 0V V 0V 0V 0V 0V Low Voltage () Install Supplied Links Load Lines Install Fuse 0 0 -, -, Unfused , Unfused 0 0 -, -, , - 90V 00V 0V 0V 00V V PH***SP Schematic for 0VA to 000VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse , -, Unfused , Unfused , -, -, , -, - 0V V 0V 0V 0V 0V Low Voltage () Install Supplied Links Load Lines Install Fuse 0 0 -, -, Unfused , Unfused 0 0 -, -, , - 0V V 0V 0V 0V 0V PH***PP Schematic for 0, and 00VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse 0 0 -, -, Unfused , Unfused 0 0 -, -, -, , -, - 0V V 0V 0V 0V 0V Low Voltage () Install Supplied Links Load Lines Install Fuse 0 0 -, -, Unfused , Unfused 0 0 -, -, , - Page of 9
22 HPS Im p e r ato r Series - Wiring Schematic Drawings continued 0V V 0V 0V 0V 0V PH***PP Schematic for 0VA to 00VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse 0 0 -, -, Unfused , Unfused 0 0 -, -, -, , -, - 0V V 0V 0V 0V 0V Low Voltage () Install Supplied Links Load Lines Install Fuse 0 0 -, -, Unfused , Unfused 0 0 -, -, , - Dotted line represents supplied jumper lead* 00V/V/0V 0V/0V/0V 0V/0V/0V PH***MBMH Schematic for 0 and VA Units High Voltage () Install Supplied Jumpers Supply Lines Install Fuse 00 0 None, Unfused None, Unfused None, Unfused , -, , -, , -, - 0V/V/0V 00V/9V/90V *This primary fuse jumper is supplied the primary fuse kit only. Low Voltage () Install Supplied Jumpers/ Load Lines Install Fuse (Secondary Volts) Links Between Terminals Connect To Clips To 0 0 None, Unfused None, Unfused 0 0 None, None, - PH***MBMH Schematic for 00VA to 00VA Units Dotted line represents supplied jumper lead* 00V/V/0V 0V/0V/0V 0V/0V/0V High Voltage () Install Supplied Jumpers Supply Lines Install Fuse 00 0 None, Unfused None, Unfused None, Unfused , -, , -, , -, - 0V/V/0V 00V/9V/90V *This primary fuse jumper is supplied the primary fuse kit only. Low Voltage () Install Supplied Jumpers/ Load Lines Install Fuse (Secondary Volts) Links Between Terminals Connect To Clips To 0 0 None, Unfused None, Unfused 0 0 None, None, - Page of 9
23 HPS Im p e r ato r Series - Wiring Schematic Drawings continued 0V Dotted line represents supplied jumper lead* 00V V PH***MEMX Schematic for 0, and 00VA Units High Voltage () Install Supplied Jumpers Supply Lines Install Fuse None, Unfused 00 None, Unfused 0 None, Unfused -, -, , -, - 0 -, -, - 0V 0V *This primary fuse jumper is supplied the primary fuse kit only. Low Voltage () Install Supplied Links Load Lines Install Fuse 0 -, -, Unfused 0 -, Unfused 0 -, -, - 0 -, - 0V Dotted line represents supplied jumper lead* 00V V PH***MEMX Schematic for 0VA to 000VA Units High Voltage () Install Supplied Jumpers Supply Lines Install Fuse None, Unfused 00 None, Unfused 0 None, Unfused -, -, , -, - 0 -, -, - 0V 0V *This primary fuse jumper is supplied the primary fuse kit only. Low Voltage () Install Supplied Links Load Lines Install Fuse 0 -, -, Unfused 0 -, Unfused 0 -, -, - 0 -, - PH***MGJ Schematic for 0, and 00VA Units 0V Dotted line represents supplied jumper lead* V 0V High Voltage () Install Supplied Jumpers Supply Lines Install Fuse 0 None, Unfused None, Unfused 0 None, Unfused 0 -, -, - -, -, - 0 -, -, - 0V 0V *This primary fuse jumper is supplied the primary fuse kit only. Low Voltage () Install Supplied Links Load Lines Install Fuse 0 -, -, Unfused 0 -, Unfused 0 -, -, - 0 -, - Page of 9
24 HPS Im p e r ato r Series - Wiring Schematic Drawings continued PH***MGJ Schematic for 0VA to 000VA Units 0V Dotted line represents supplied jumper lead* V 0V High Voltage () Install Supplied Jumpers Supply Lines Install Fuse 0 None, Unfused None, Unfused 0 None, Unfused 0 -, -, - -, -, - 0 -, -, - 0V 0V *This primary fuse jumper is supplied the primary fuse kit only. Low Voltage () Install Supplied Links Load Lines Install Fuse 0 -, -, Unfused 0 -, Unfused 0 -, -, - 0 -, - Page 9 of 9
HPS Imperator. Innovative Solutions. Progressive. Encapsulated Machine Tool Industrial Control Transformers
Progressive Innovative Solutions HPS Imperator Encapsulated Machine Tool Industrial Control Transformers Lifetime Warranty Unique Terminal Block Innovative Fusing Method Patented Design HPS Imperator Control
More informationHPS Imperator Encapsulated Industrial Control Transformer
HPS Imperator Innovative Design The Perfect Solution Features and enefits The HPS Imperator series is a unique innovative and compact design that provides the ideal solution for any industrial control
More informationMachine Tool Industrial Control Transformers
Hammond Power Solutions Inc. Page of Machine Tool Industrial Control Transformers The HPS Imperator TM series of machine tool rated industrial control transformers are specifcally designed to meet high
More informationMachine Tool Industrial Control Transformers
Hammond Power Solutions Inc. Page of Machine Tool Industrial ontrol Transformers The HPS Imperator TM series of machine tool rated industrial control transformers are specifcally designed to meet high
More informationPH250MQMJ CNTL 250VA 240X X240
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 PH250MQMJ CNTL 250VA 240X480-120X240 Hammond Power Solutions Catalog Number Manufacturer Description Weight per unit Product
More informationControl Transformers
ontrol Transformers HPS Imperator TM, QE, MV Series Industrial ontrol Transformers ontrol Transformer Quick Selection harts... 0 What Is A ontrol Transformer?... ontrol Transformer Selection Guide... HPS
More informationINDUSTRIAL CONTROL AND GENERAL PURPOSE ENCLOSED TRANSFORMERS
INDUSTRIAL ONTROL AND GENERAL PURPOSE ENLOSED TRANSFORMERS HPS Imperator, HPS Spartan, HPS Fusion and Q Series Transformers ontrol Transformer Quick Selection harts... 8 What Is A ontrol Transformer?...
More informationHPS Imperator Series Control Transformers meet or exceed the standards established
HPS IMPRATOR HPS Imperator Machine Tool Industrial ontrol Transformer The Perfect Solution The HPS Imperator line of machine tool industrial control transformers are specifically designed to meet the high
More informationHPS Imperator Machine Tool Industrial Control Transformer
HPS Imperator Machine Tool Industrial ontrol Transformer The Perfect Solution The HPS Imperator line of machine tool industrial control transformers are specifically designed to meet the high inrush industrial
More informationHPS Spartan Industrial Open Core & Coil Control Transformer
HPS Spartan Industrial Open Core & Coil Control Transformer Our Company Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the
More informationHPS Spartan. Industrial Open Core & Coil Control Transformer
HPS Spartan Industrial Open Core & Coil Control Transformer OUR COMPANY Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the
More informationHPS Fusion General Purpose Enclosed Transformer
HPS Fusion General Purpose Enclosed Transformer Our Company Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the short wave radio
More informationHPS Fusion General Purpose Enclosed Transformer
HPS Fusion General Purpose Enclosed Transformer Our Company Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the short wave radio
More informationIndustrial Control Transformers
6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids
More informationICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices
ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers
More informationType FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers
Type FEC Epoxy Encapsulated, Copper-Wound Transformers ISO 900:2008 REGISTERED 0 Transformer Selector Guide Type FEC Transformers...Page 02 Primary Fusing Option...Page 07 Primary Overcurrent Selection...Page
More informationINDUSTRIAL CONTROL TRANSFORMERS
INDUSTRIAL ONTROL TRANSORMRS PT, PH, PTD, PHD, SL, Q, M, VM, MV Series ontrol Transformers ontrol Transformer Quick Selection harts... 30 What Is A ontrol Transformer?... 31 ontrol Transformer Selection
More informationIndustrial Control Power Transformers Class MT
Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments
More informationTA Ta VA CTRL-XFRMR
3804 South Street 7964-7263, TX Nacogdoches Phone: 936-69-7941 Fax: 936-60-468 TA2437 Ta-2-437 10VA CTRL-XFRMR Acme Electric Catalog Number TA2437 Manufacturer Acme Electric Description Control Transformer,
More informationMfg. Part No.* VA ACCESSORIES
Find Datasheets Online CONTROL HPS IMPERATOR MACHINE TOOL INDUSTRIAL CONTROL Up to 100VA 00V class 50/0 Hz Superior insulation system Constructed with high quality silicon steel laminations PRIMARY: 240/480,
More informationCPT Series Control Transformers
CPT Series Control s 50 VA to 500 VA 480 VAC Primary 120 VAC Secondary (Inrush VA data should be obtained from the device manufacturers.) The inrush load power factor is difficult to determine without
More informationHPS Fortress. Commercial Encapsulated Distribution Transformers
HPS Fortress Commercial Encapsulated Distribution Transformers OUR COMPANY Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the
More informationInexpensive as. Applications
Our Company Hammond Power Solutions (HPS) was established in in Guelph, Ontario and has grown from a small family owned business in the short wave radio market, to the industry leader in magnetic transformer
More informationIndustrial Control Power Transformers
09/10/15 Class MT Features b Enclosed coils (50-5000); Completely encloses the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial
More informationSelection Guide. Control Circuit and Load Protection
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationBulletin 1497A Machine Tool Transformers
Bulletin A Overview/Catalog Number Explanation Bulletin A Bulletin A are designed to reduce supply voltages to control circuits. The complete line of transformers is available with optional factory-installed
More informationBulletin 1497A Machine Tool Transformers
Bulletin A Overview/Catalog Number Explanation Bulletin A Bulletin A are designed to reduce supply voltages to control circuits. The complete line of transformers is available with optional factory-installed
More informationControl Circuit Transformers
Technical Data Control Circuit Transformers Bulletin Numbers 1497, 1497A, 1497B, 1497D Topic Page Summary of Changes 1 Control Circuit Transformers Product Overview 2 Bulletin 1497 Global Control Circuit
More informationIndustrial Control Transformers
The SBE - Encapsulated, Copper Wound Series The SolaHD SBE Encapsulated industrial control transformers are epoxy encapsulated to seal the transformer windings against moisture, dirt and industrial contaminants.
More informationClass I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.
Class I Division 2 10 1 to 25 kva Applications n Class I Division 2 units are used in hazardous locations to maintain a safe environment. Specifications n Class I Division 2, Groups A, B, C, D n T3C temperature
More informationIndustrial Control Transformers
Industrial Control Types MTE and MTK.1 Standards and Certifications................................. Catalog Selection.................................. Type MTE...............................................
More informationENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS
Hammond Power Solutions Inc. Page 1 of 1 ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS HPS Titan has been designed to operate in harsh environments/hazardous locations where dangerous gases, liquids,
More informationIndustrial Control Transformers
Industrial Control Transformers 5 The SBE - Encapsulated Series The SBE Encapsulated industrial control transformers are epoxy encapsulated to seal the transformer windings against moisture, dirt and industrial
More informationControl Transformers
J., APRJL, 1983 SUP RSEPES1/8111TION Control Transformers FILE: Control Products Catalog Machine Tool Transformer Disconnects CONTENTS Description Class Pages General............ 97... 23 Application Data.........
More informationPRODUCTS: POWER SUPPLY
PRODUCTS: POWER SUPPLY Impact Lighting Inc. All rights reserved. Impact Lighting Inc. Reserves the right to change specifications without notice. 138 POWER SUPPLY 15W AC-DC [12V/1.25A] UNIVERSAL POWER
More informationBulletin A 1497B 1497D Type Control Circuit Transformer Machine Tool Transformer Control Power Transformer General Purpose Transformer
Bulletin, A, B, D Transformers Product Overview Transformers Bulletin A B D Type Control Circuit Transformer Machine Tool Transformer Control Power Transformer General Purpose Transformer Features Single,
More informationABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet
ABB Instruction Leaflet 41-137.2E Effective: February 1994 Supersedes I.L. 41-137.2D, Dated February 1973 ( )Denotes Change Since Previous Issue. Type KRV Directional Before putting relays into service,
More informationEngineered solutions for power and the environment
C e n t u ry S e r i e s I n d u s t r i a l C o n t r o l T r a n s f o r m e r s Engineered solutions for power and the environment s we celebrate our 100th nniversary, the Dongan Team wishes to thank
More informationSingle-Phase Ventilated
Single-Phase Ventilated 1 15 to 1,650 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency
More informationGeneral Purpose Buck - Boost Wiring Diagrams... 86
SECTION LOW VOLTAGE/ LIGHTING TRANSFORMERS General Purpose... 84 Buck - Boost... 85 Wiring Diagrams... 8 LOW VOLTAGE LIGHTING TRANSFORMERS & POWER SUPPLIES Low Voltage Lighting A greater selection for
More informationContactors & Starters Index
ontactors & Starters Index NEMA ontrol Description Page Number General Information - HP... A Magnetic ontactors - HP...4 A Magnetic Reversing ontactors - HP... 4 A Magnetic Starters - HP... A Magnetic
More informationA - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION
ABB Effective: November 1990 This Addendum Supersedes all Previous Addenda Addendum to Instruction Leaflet 41-137.3H Type KRD-4 Directional Overcurrent Ground Relay A - Add New Information C - Change Existing
More information9070T150D1 Industrial Control Transformer, 150VA
Product Data Sheet 9070T150D1 Industrial ontrol Transformer, 150 Technical haracteristics Application Approvals atalog Reference Number Depth Height Width Winding Material Temperature Rise Type Primary
More informationHPS TITAN HPS TITAN. Three Phase. Single Phase
The HPS Titan line of transformers have been designed for installation in harsh environments where efficiency and performance are key. Typical applications include institutional, commercial, industrial,
More informationCoil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)
14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose
More informationEnclosed Full-Voltage Starters
GE Energy Connections Made in Canada Enclosed Full-Voltage Starters * ca.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal
More informationCoil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q
14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose
More informationTCM D Single Zone, 24 Volt DC Timer Control Module User s Manual D-M-E Company
TCM-03-024D Single Zone, 24 Volt DC Timer Control Module User s Manual D-M-E Company D-M-E Company TCM-03-024D Page 1 SAFETY D-M-E Company products have been designed to be safe and simple to operate.
More informationMERCURY CONTACTORS & RELAYS
MERCURY CONTACTORS & RELAYS PHONE: 704-399-4248 FAX: 704-399-4167 WWW.SETHERMAL.COM INDEX GLOSSARYOFTERMS&EXPRESSIONS...1 GENERALINFORMATIONFEATURES&SELECTIONFACTORS...13 MERCURY TO METAL CONTACTORS AND
More informationTransformer Disconnects
Disconnects For Control Panel Lighting and Auxillary Power UL and CUL Listed TÜV Rheinland Licensed CE Marked Series Electric Manufacturing Company Table of Contents TDLK Series NEMA 1-12... 3-4 TDEK Series
More informationDry Type Distribution Transformers
Selection Steps A. Use the following steps below to manually select a transformer. B. Find the electrical load requirements. These are: 1. Load operating voltage. 2. Load frequency (expressed in Hz). 3.
More informationSection 10: Terminal Blocks
Terminal Blocks Section : Terminal Blocks CR151K Resilient Modular Terminal Blocks DIN-rail Mounted Terminal Blocks (CR151K)...-2 Product Tables...-3, -4 Accessories...-3, -4 Technical Data...-5 Outlines
More informationYS Series Contactors YS1N- F11 ****
YS Series YS Series Contactors Key features of the YS Series include: Compact size AC and C coil, reversing and non-reversing Weld-resistant silver alloy contacts No cadium used in contacts Highly reliable
More informationKtec Contactors and thermal overloads
Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America
More informationB CW POWER RELAY
41-241.31B CW POWER RELAY nected in such a way that current, (I A ), leads voltage, (V BA ), by 150 degrees when the motor is operating at unity power factor. Loss of excitation to the motor causes a large
More information3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay
41-106E Type CO-4 Step-Time Overcurrent Relay A core screw accessible from the top of the switch provides the adjustable pickup range. The IIT contacts are connected in the trip circuit to trip instantaneously.
More informationTerminal Blocks. Section 12. Control Catalog 12-1
CR151K Resilient Modular Terminal Blocks CR151C (top) and CR151A Modular Terminal Blocks DIN-rail Mounted Terminal Blocks (CR151K)...12-2 Product Tables...12-3, 12-4 Accessories...12-3, 12-4 Technical
More informationHPS Fortress. Encapsulated Transformers for Commercial Applications
HPS Fortress Encapsulated Transformers for Commercial Applications HPS Fortress Encapsulated Transformers for Commercial Applications HPS Fortress is an innovative design that provides the ideal solution
More informationClass H & K Fuse Holders - 250/600 Volt
Class H & K - 250/0 Volt Specifications: Approved for 10,000 Amp Withstand Rating and Short Circuit Current Ratings (SCCR) UL Listed File No. IZLT.E35113 CSA Certified File No. LR21455 RoHS Compliant &
More informationRheem High Efficiency Air Handler
Air Handlers Rheem High Efficiency Air Handler Constant Torque Motor (ECM) Efficiencies up to 14 SEER The RH1T feature a Constant Torque motor (ECM) and a piston refrigerant control for efficient and reliable
More information50 Series. Features. Suffix Suffix Series Voltage Combinations
Features C 50 Combinations Suffix -052 x 24 ll Copper Windings Rugged coil mounted screw terminals UL Class 105 C insulation system, 55 C temperature rise through 750 UL Class 10 C insulation system, C
More informationEnclosed Full-Voltage Starters
GE Energy Connections Made in USA Enclosed Full-Voltage Starters * www.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal for
More informationSECTION 3 HPS CENTURION R REACTORS AND RC DV/DT FILTERS
HPS CENTURION R REACTORS AND RC DV/DT FILTERS Single and Three Phase Why Choose a Line Reactor?... 98 Construction Features... 100 HPS Centurion R Reactors Specifications... 101 Part Number Guide... 102
More informationThree-Phase Ventilated
Three-Phase Ventilated 2 15 to 2,500 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency
More information2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay
41-100K 2.0 CONSTRUCTION AND OPERATION The type CO relays consist of an overcurrent unit (CO), either an Indicating Switch (ICS) or an ac Auxiliary Switch (ACS) and an Indicating Instantaneous Trip unit
More informationSineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING
SineWave Guardian TM 380V 600V INSTALLATION GUIDE FORM: SWG-IG-E REL. October 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of
More informationNEMA 1 ( IP23 ) NEMA 12 ( IP54 ) Spec-Tech Industrial Electric
NEMA 1 ( IP23 ) NEMA 12 ( IP54 ) Celebrate Our 100th Anniversary With Us Table of Contents TDL Series NEMA 1-12... 3-4 TDE Series NEMA 1-12.... 5-6 TDA Series NEMA 1-12.... 7-8 Auxiliary Power TLA Series
More informationTransformers 6. Gross Automation (877)
Transformers 6 Hevi-Duty Family of Transformers Sola/Hevi-Duty offers a broad range of transformers to meet many applications. These dry-type transformers are offered encapsulated, ventilated or non-ventilated,
More informationType IMC Indoor current transformer
Instrument transformers Type IMC Indoor current transformer Product features 600 volt indoor 10 kv BIL 25 through 400 Hertz amperes: 50-1000 2.5" (64 mm) round window Designed for variable applications
More informationSelection Guide Motor Control Device Solutions
Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements
More informationTYPE KF UNDER-FREQUENCY RELAY A. Figure 1: Type KF Relay for 60 Hertz without Case. (Front & Rear View.) Front View Rear View
41-503.21A TYPE KF Front View Rear View Figure 1: Type KF Relay for 60 Hertz without Case. (Front & Rear View.) 2 TYPE KF 41-503.21A lower pin bearing, which is mounted on the frame, with respect to the
More informationCircuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You
Circuit Breakers Specifically For You Excerpt from Master Catalogue Circuit Breakers DIN rail mount, thermal/magnetic circuit breakers. Their compact dimensions, ease of mounting and excellent performance
More informationTanning Bed Transformers
Tanning Bed Transformers Complete line of transformers designed specifically for the tanning industry. SolarTran Tanning Bed Transformers are specifically designed to serve the voltage transformation needs
More informationType CRN-1 Reverse Power Relay 50 and 60 Hertz
ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065 Instruction Leaflet 41-251.2P Effective: June 1991 Supersedes I.L. 41-251.2N Dated April 1988 ( )Denotes Change
More informationEngineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)
4 Engineering Information Principles of Operation A solenoid valve is a combination of two basic functional units: A solenoid (electromagnet) with its core A valve body containing one or more orifices
More informationCOM Overcurrent Relay
41-102.1B COM Overcurrent Relay Figure 1: COM-5 Class 1E Relay (Front View) 9664A28 Photo Figure 2: COM-5 Class 1E Relay (Rear View) 9664A29 Photo Photo needed here 2 COM Overcurrent Relay 41-102.1B 3
More informationFULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION
505 z 509 FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION The movable contacts are carried in stainless steel cages which in turn are mounted in cavities in the molded portion of the cross bar. This
More informationBallasts For High Intensity Discharge Lamps
allasts For High Intensity Discharge Lamps Universal Means Higher Expectations In High Intensity Discharge Universal Lighting Technologies ( Universal ) offers a wide array of ballasts for High Intensity
More informationM T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation
M T E C o r p o r a t i o n dv/dt Filter Series A 440-600 VAC USER MANUAL PART NO. INSTR - 019 REL. 041119 2004 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation dv/dt Filter is designed
More informationAF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up
More informationABB. Type CRQ Directional Negative Sequence Relay for Ground Protection B 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION CAUTION
ABB Instruction Leaflet 41-163.2B Effective: January 1977 Supersedes I.L. 41-137.3A, Dated September 1974 ( ) Denotes Change Since Previous Issue Type CRQ Directional Negative Sequence Relay for Ground
More informationElectrical Components
Table of Contents ELECTRICAL COMPONENTS Electrical Components 3 ELECTRICAL COMPONENTS 1 Electrical Cables.... 3-1 - 3-2 Hitch Ball & Grounding Jumpers.... 3-3 Fuses... 3-4 - 3-6 Fuse Packages... 3-7 Cord
More information2 SLR Series Line Reactors... 50
Drive Isolation & Protection Line Reactors Drive Isolation Transformers 2 SLR Series Line Reactors... 50 Drive Isolation Transformers... 51 Selection Table and Design Styles... 52 Electrical Connections...
More informationAC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave
Rectifiers for use with Armature Actuated Brakes Product Overview NOTE: For brake response times with and without rectifiers see page 94. Full Wave A rectifier in which both positive and negative half-cycles
More informationLow Voltage Lighting Power Supplies
SECTION VI LO VOLTAGE LIGTING TRANSFORMERS & POER SUPPLIES Low Voltage Lighting Power Supplies A greater selection for your indoor and outdoor low voltage lighting projects hy Low Voltage? Acme s Low Voltage
More informationTotally Enclosed Non-Ventilated
5 15 to 500 kva 5 Applications n Designed for commercial and industrial loads in challenging environments Specifications n NEMA3R rated enclosure n Single Phase units 15 through 100 kva n Three Phase units
More informationHOW TO ORDER SPECIFY AS SHOWN BELOW EXAMPLE #1
MERCURY TO METAL CONTACTORS AND RELAYS GLASS SEAL GUIDE RETAINER TEFLON GUIDE MAGNETIC SLEEVE BOBBIN TERMINAL WELD RING CERAMIC INSULATOR ELECTRODE METAL CAP DESCRIPTION MERCURY TO METAL CONTACTOR: The
More informationSoft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP
Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD Soft starting of 3-phase scroll compressors up to 95Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user
More informationIndustrial and Commercial Duty IEC Motors
Industrial and Commercial Duty IEC Motors A Regal Brand Five product families delivering a world of opportunity LEESON Passport Series IEC Motors. There s a world of opportunity right here at home. The
More informationManual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X
Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and
More informationSwitches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC)
SWITCH SELECTION GUIDE Toggle Switches SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY (Resistive @ 115VAC, 28VDC) T1 2 or 3 Position, Momentary, 8A MIL-PRF-83731 15/32" or 1/4" dia.
More informationMiniature Liquid Level Sensors
C US File No. 1636 (L90200-27) Applications Typical applications include automatic vending machines, photocopiers, small collection tanks, miniature pumping stations, pilot plants and similar small system
More information4.1. Definite Purpose Contactors and Starters. Contents
. Definite Purpose and Starters Product Overview and Starters Definite Purpose and Starters Contents Description Page 20 0A, Compact Single- and Two-Pole C25................................ V5-T- 5 360A,
More informationSafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin
SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin Contents 1. Introduction 2 2. Product highlights 2 3. Available configuration/competitive
More informationCapacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality
Individual & fixed capacitor banks Low Voltage L O W V O L T A G E N E T W O R K Q U A L I T Y Individual & fixed bank Capacitors Description High reliability Well proven features of ABB dry type power
More informationXMC0 Series DEFINITE PURPOSE CONTACTORS
DESCRIPTION American Zettlers XMC0 series of Definite Purpose Contactors are electromechanical switching devices designed ideally for the HVAC industry. The most common applications of our contactors are
More informationR6F30A1S R6F30A1S 1P 60A 600V Fuse BLK. Features. Long Description
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category Features Clip Type Fuse Current Rating Fuse Type
More informationAT120A-E; AT140A-E; AT150A,B,D-F; AT160B; AT175A-D,F Transformers
AT0A-E; AT0A-E; AT50A,B,D-F; AT60B; AT75A-D,F Transformers FEATURES PRODUCT DATA AT0 is rated at 0 VA. AT0 is rated at 0 VA. AT50 is rated at 50 VA. AT60 is rated at 60 VA. AT75 is rated at 75 VA. All
More informationSafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin
2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin SafeGear Motor Control Center Arc resistant Metal-Clad construction Descriptive Bulletin Table of Contents
More informationSolid-State Relays. Solid-State Relays. Features. Description. Overview
Features Rugged, epoxy encapsulation construction 4,000 volts of optical isolation Subjected to full load test and six times the rated current surge before and after encapsulation Unique heat-spreader
More information