Low Voltage Lighting Power Supplies

Size: px
Start display at page:

Download "Low Voltage Lighting Power Supplies"

Transcription

1 SECTION VI LO VOLTAGE LIGTING TRANSFORMERS & POER SUPPLIES Low Voltage Lighting Power Supplies A greater selection for your indoor and outdoor low voltage lighting projects hy Low Voltage? Acme s Low Voltage Lighting products provide a safe, long lasting, highly reliable power source; a perfect selection for landscape applications as well as interior use. Low voltage lighting is a creative medium with unlimited application possibilities. Low voltage lighting benefits include: Precision beam control More light intensity per watt Less radiated heat Greater efficiency Longer life Safer to use Easy installation A high return on end-user investment Acme Advantages Greater selection Acme offers one of the largest selections of low voltage lighting transformers in the industry. The addition of our premium line (Group I) that includes a photocell and 24-hour timer and the versatile Group V transformers gives the landscape architect or contractor almost unlimited application possibilities. Please use the convenient Selection Guide on the facing page to aid in your selection. More value Acme low voltage transformers and power supplies are available in a wide range of options and models that are all UL listed for use indoors or outdoors. All Acme products are backed by a 10-year limited warranty (see inside back cover for details). More Power Power supplies are available in ratings of 100 through 1500 and transformers in ratings of 100 through 1000 ; Group VI Buck Boost in.05 through 10 KVA. More convenience Screw lug output terminals on Group I, II and III power supplies provide fast low voltage connections regardless of transformer location. Just slip your wires into the lug and tighten there s no wrapping the wire around a screw post. Groups IV, V and VI transformers have copper lead wires for hardwiring. Circuit breakers for instant reset (except pool and spa and Buck Boost). No fumbling with fuses. Generous wiring compartment, too! More protection A full fault current carrying Faraday Shield (except Buck Boost) prevents 120 volts from reaching the 12 volt side, as required by UL-1571 and UL Features and Options The convenient Selection Guide on the facing page provides you with the data you need to select the product that best meets your requirement. Complete product selection data, dimensions and wiring diagrams are contained on the following pages. If you need help in your selection, or if you have questions, just call technical services at

2 SECTION VI LO VOLTAGE LIGTING TRANSFORMERS & POER SUPPLIES SELECTION GUIE Tap Switch Standard 11,12,13V or on all No No No No 12/ 11/22, 12/24, 13/26 Units POER SUPPLIES TRANSFORMERS GROUP I GROUPS II & III GROUP IV GROUP V GROUP VI TLV and Pool and Spa Buck Boost Features/Options TLVA T T and T-1 T-1 T-1 and T-2 Catalog No. Catalog No. Catalog No. Catalog No. Catalog No , Ratings through through and through through (atts, VA, KVA) 600 atts 1500 atts 500 atts 1000 VA 10 KVA 24 our Timer Standard and Photocell on all units Primary Input 120 Volts 120 Volts 120 Volts Secondary Output No No No No 120 Volts or 120 x Volts Volts Selection of Selection of 12, 13, 14 V or dual or dual taps or 12 x 24 V 12/24 V units 12/24 V units provided Primary Line Cord Standard Optional 6 with Plug 6 through 500 No No No ardwired Primary NA Optional Yes Yes Yes Auto Thermal Reset Auto Thermal Reset Auto Thermal Auto Thermal Reset No Overload Primary through 300 through 250 Reset Protection: Secondary Circuit Optional Circuit Breaker (s) Circuit Breakers No Breakers No (Group II) Output Screw Lug Screw Lug Copper Copper Copper iring Terminals Terminals Lead ires Lead ires Lead ires On Off Auto Switch Standard on all units No No No No UL Listed Yes Yes Yes 3 Yes Yes CSA Certified No No No Yes Yes Faraday Shield Product arranty Yes Yes Yes Yes No 10 Years 1 10 Years 10 Years 10 Years 10 Years UL-3R Indoor/Outdoor Yes Yes Yes 2 No Yes Enclosure 1 Timer and Photocell limited to 3 years. 2 Standard Pool and Spa enclosure is painted cold-rolled steel. Stainless steel enclosure is available. 3 UL listed for use with low voltage submersible lights. 87

3 ow To Size Your Power Supply Easy Two-Step Selection 1. Add the total lamp wattage of each circuit you plan to use. For example: if you have 2 circuits, each with four 25 watt lamps, your total wattage is: 2 circuits x 4 lamps = 8 lamps x 25 watts = 200 watts. 2. Go to the appropriate selection chart. The catalog number identifies the power supply size and output voltage (see example below). You won t find the exact 200 watts needed, so go to the next highest catalog number TLV S. This leaves you 50 watts of reserve power available for other low voltage applications. See chart below for recommended wire sizes and voltage drop. If you use a power supply with a dual 12/24 volt secondary, each 12 volt circuit is rated at one half the total power supply wattage. Example: A TLV SC has two 12 volt 125 watt output circuits. Refer to Interpreting Power Supply Catalog Numbers for further explanation of catalog numbers. immer Notice Only use dimmers designed and rated for magnetic loads. Consult the dimmer manufacturer for recommendations regarding your lighting application. Interpreting Power Supply Catalog Numbers (Groups I, II, III) GROUP I GROUP II GROUP III Power Supply TLVA S C with Breaker(s) Timer, Photocell 100 atts 12 Volt Output Shielded Line Cord (Standard) Power Supply with Breaker(s) 100 atts 24 Volt Output Shielded Optional Line Cord TLV S C Power Supply without Breaker(s) 250 atts 24 Volt Output Shielded T S Recommended ire Size and Voltage rop 1 12 VOLT SYSTEM ire Size (Gauge) ATTS (VA) Per Circuit Maximum Secondary ire Length in Feet (Meters) (22.9) (11.3) (7.6) (5.8) (4.8) (3.7) (3.4) (2.7) (2.4) (2.1) (2.1) (1.8) (1.8) (1.5) (1.5) (1.5) (1.2) (1.2) (1.2) (1.2) (36.0) (18.0) (11.9) (9.1) (7.3) (6.1) (5.2) (4.6) (4.0) (3.7) (3.4) (3.0) (2.7) (2.4) (2.4) (2.1) (2.1) (2.1) (1.8) (1.8) (57.3) (28.7) (19.2) (14.5) (11.6) (9.4) (8.2) (7.3) (6.4) (5.8) (5.2) (4.9) (4.3) (4.0) (4.0) (3.7) (3.4) (3.0) (3.0) (2.7) (91.1) (45.4) (30.5) (22.9) (18.3) (15.2) (13.1) (11.3) (10.1) (9.1) (8.2) (7.6) (7.0) (6.4) (6.1) (5.8) (5.5) (5.2) (4.9) (4.6) (145.1) (72.5) (48.5) (36.3) (29.0) (24.1) (20.7) (18.3) (16.2) (14.6) (13.1) (12.2) (11.3) (10.4) (9.8) (9.1) (8.5) (7.9) (7.6) (7.3) (1.2) (0.9) (0.9) (0.9) (0.9) (1.8) (1.5) (1.5) (1.5) (1.5) (2.7) (2.7) (2.4) (2.4) (2.4) (4.3) (4.3) (4.0) (3.7) (3.7) (7.0) (6.7) (6.4) (6.1) (5.8) 24 VOLT SYSTEM ire Size (Gauge) ATTS (VA) Per Circuit Maximum Secondary ire Length in Feet (Meters) (49.7) (22.9) (15.2) (11.3) (9.1) (7.6) (6.4) (5.8) (5.2) (4.6) (4.3) (3.7) (3.7) (3.4) (3.0) (2.7) (2.7) (2.4) (2.4) (2.1) (92.2) (36.0) (24.1) (18.0) (14.3) (11.9) (10.4) (9.1) (7.9) (7.3) (6.7) (6.1) (5.5) (5.2) (4.9) (4.6) (4.3) (4.0) (3.7) (3.7) (114.6) (57.3) (38.1) (28.7) (22.9) (19.2) (16.5) (14.3) (12.8) (11.6) (10.4) (9.4) (8.8) (8.2) (7.6) (7.3) (6.7) (6.4) (6.1) (5.8) (182.0) (91.1) (60.7) (45.4) (36.3) (30.5) (26.0) (22.9) (20.1) (18.3) (16.5) (15.2) (14.0) (13.1) (12.2) (11.3) (10.7) (10.1) (9.4) (9.1) (290.1) (145.1) (96.7) (72.5) (57.9) (48.5) (41.5) (36.3) (32.3) (29.0) (26.5) (24.1) (22.3) (20.7) (19.2) (18.3) (17.1) (16.2) (15.2) (14.6) 1 Charts are based on SPT-3 wire and a maximum.63 voltage drop at the end of the run. Many applications allow a 2.5 voltage drop (2.1) (2.1) (2.1) (1.8) (1.8) (3.4) (3.4) (3.0) (3.0) (2.7) (5.5) (5.2) (4.9) (4.9) (4.6) (8.5) (8.2) (7.9) (7.6) (7.3) (13.7) (13.1) (12.5) (12.2) (11.6) 88

4 Low Voltage Lighting Power Supplies with 24-our Timer & Photocell Mounting Bracket with Keyhole Slots Easy-to-Read Nameplate 1.38 in. (3.5 cm.) Removable Front Cover Photocell 24 hour timer Accessory Switch Voltage Regulator Switch Screw Lug Output Terminals 6 (1.8 m) Power Cord with Grounded Plug BOTTOM VIE.88 x 1.13 in. (2.2 x 2.9 cm.) Knockout Power Cord Electrical Connection iagrams FEATURES 100, 150, 300, 600 att Models. Primary, or 12/24 V Secondary, 60 z. Fully encapsulated core and coil. 24-hour timer and photocell. all mounting brackets included. UL Listed. Screw lug terminals for ease of wiring. eadfront terminal cover for added safety. 3-Position on-off-auto switch for versatility. Removable front cover, generous wiring space. 6 power cord with grounded plug. Voltage regulation switch for 11, 12 or 13 volts. Overload protection on primary and secondary sides. 10-year limited product warranty (3-years on timer/photocell). Faraday shielded for greater safety. Units OR = SELECTION CART 12/24 V Units GROUP I INPUT INPUT APPROX. IMENSIONS 2 APPROX. ATTS OUTPUT 12/ OUTPUT 1 Inches (Cm.) SIP EIGT CATALOG NO. CATALOG NO. EIGT IT EPT Lbs. (Kg.) 100 TLVA SC TLVA SC (45.7) 4.00 (10.2) 3.50 (8.9) 10 (4.5) 150 TLVA SC TLVA SC (45.7) 4.00 (10.2) 3.50 (8.9) 10 (4.5) 300 TLVA SC TLVA SC (48.3) 4.62 (11.7) 4.25 (10.8) 14 (6.4) 600 TLVA SC TLVA SC (48.3) 4.62 (11.7) 4.25 (10.8) 18 (8.2) 1 12/ denotes a three wire circuit, one output or two outputs. Each is rated at one half the nameplate wattage. 2 imensions not suitable for construction purposes. Contact factory for certified drawings. 89

5 Power Supply Specifications, imensions and Selection Electrical Connection iagrams Units OR = SELECTION CARTS 12/24 V Units GROUP II IT LO VOLTAGE CIRCUIT BREAKERS 3 ITOUT LINE COR IT LINE COR 120 VOLT INPUT 120 VOLT INPUT 120 VOLT INPUT 120 VOLT INPUT APPROX. ATTS 12 VOLT OUTPUT 12/24 VOLT OUTPUT 4 12 VOLT OUTPUT 12/24 VOLT OUTPUT 4 APPROX. IMENSIONS 5 SIP UL-506 LISTE UL-506 LISTE UL-1012 LISTE UL-1012 LISTE Inches (Cm.) EIGT CATALOG NO. CATALOG NO. CATALOG NO. CATALOG NO. EIGT IT EPT Lbs. (Kg.) 100 TLV S 1 TLV S 1 TLV SC 1 TLV SC (33.0) 3.91 (9.9) 3.98 (10.1) 9 (4.1) 150 TLV S 1 TLV S 1 TLV SC 1 TLV SC (33.0) 3.91 (9.9) 3.98 (10.1) 9 (4.1) 250 TLV S 1 TLV S 1 TLV SC 1 TLV SC (33.0) 3.91 (9.9) 3.98 (10.1) 12 (5.4) 500 TLV S 2 TLV S 1 TLV SC 2 TLV SC (35.6) 4.66 (11.8) 4.60 (11.7) 17 (7.7) 750 TLV S 2 TLV S (35.6) 4.66 (11.8) 4.60 (11.7) 20 (9.1) 1000 TLV S 2 TLV S (39.0) 5.41 (13.7) 5.23 (13.3) 28 (12.7) 1500 TLV S (39.0) 5.41 (13.7) 5.23 (13.3) 35 (15.9) GROUP III ITOUT LO VOLTAGE CIRCUIT BREAKERS ITOUT LINE COR IT LINE COR 120 VOLT INPUT 120 VOLT INPUT 120 VOLT INPUT 120 VOLT INPUT APPROX. ATTS 12 VOLT OUTPUT 12/24 VOLT OUTPUT 4 12 VOLT OUTPUT 12/24 VOLT OUTPUT 4 APPROX. IMENSIONS 5 SIP UL-506 LISTE UL-506 LISTE UL-1012 LISTE UL-1012 LISTE Inches (Cm.) EIGT CATALOG NO. CATALOG NO. CATALOG NO. CATALOG NO. EIGT IT EPT Lbs. (Kg.) 100 T S T S T SC T SC (33.0) 3.91 (9.9) 3.98 (10.1) 9 (4.1) 150 T S T S T SC T SC (33.0) 3.91 (9.9) 3.98 (10.1) 9 (4.1) 250 T S T S T SC T SC (33.0) 3.91 (9.9) 3.98 (10.1) 12 (5.4) 500 T S T S T SC T SC (35.6) 4.66 (11.8) 4.60 (11.7) 17 (7.7) 750 T S T S (35.6) 4.66 (11.8) 4.60 (11.7) 20 (9.1) 1000 T S T S (39.0) 5.41 (13.7) 5.23 (13.3) 28 (12.7) 1500 T S (39.0) 5.41 (13.7) 5.23 (13.3) 35 (15.9) 1 Push to reset Thermal Breaker. 2 Magnetic Breaker Toggle On/Off. 3 Low voltage circuit breakers are for protection only and are not to be used as an on/off switch for 100 and 150 watt 12 volt units or on 100, 150 and 250 watt 12/24 volt units. 4 12/24 volt output denotes a three-wire circuit, one 24 volt output or two 12 volt outputs. Each 12 volt output is rated at 1/2 nameplate wattage. 5 imensions not for construction purposes. Contact factory for certified drawings. 90

6 Pool and Spa Specifications imensions and Selection ELECTRICAL CONNECTION IAGRAM 100, 300 & 500 VA MAXIMUM INING RISE 115 C BLACK ITE 14V 13V 0V ENCLOSURE MUST BE GROUNE GROUP IV 120 VOLT INPUT 12, 13 OR 14 VOLT OUTPUT 1Ø, 60 z COL - ROLLE STAINLESS STEEL APPROX. IMENSIONS APPROX. KNOCKOUT PRIMARY SECONARY VA STEEL ENCLOSURE ENCLOSURE Inches (Cm.) SIP. EIGT SIZE CURRENT LS. LS. RATING CATALOG NO. 1 CATALOG NO. 1 EIGT IT EPT Lbs. (Kg.) In. (Cm.) (MAX. AMPS) 2 PCS. OF # 4 PCS. OF # 100 T SL T SL 8.40 (21.3) 3.50 (8.9) 4.83 (12.3) 7 (3.2) Two Single 100 T SR T SR 8.40 (21.3) 3.50 (8.9) 4.83 (12.3) 7 (3.2).875 (2.2) CU 12 CU 300 T SL T SL 8.40 (21.3) 4.22 (10.7) 5.50 (14.0) 12 (5.4) Two Single 300 T SR T SR 8.40 (21.3) 4.22 (10.7) 5.50 (14.0) 12 (5.4).875 (2.2) CU 12 CU 500 T SL T SL (25.4) 4.41 (11.2) 5.66 (14.4) 15 (6.8) Two Single 500 T SR T SR (25.4) 4.41 (11.2) 5.66 (14.4) 15 (6.8).875 (2.2) CU 10 CU GUIE CART 2 For Selecting Secondary Voltage Tap To Be Used ith Various ire Sizes For Given istances Between Transformer And Lamps ISTANCE FT. (M.) FROM TRANSFORMER TO LAMPS FOR 100 ATT LOA IRE SIZE LESS TAN (Gauge) 30 (9.1) 30 (9.1) 60 (18.3) 90 (27.4) 120 (36.6) 150 (45.7) 180 (54.9) 210 (64.0) 240 (73.2) 270 (82.3) 300 (91.4) 14 13V 14V Use Larger ire Size 12 13V 13V 14V Use Larger ire Size 10 13V 13V 14V 14V Use Larger ire Size 8 13V 13V 13V 14V 14V 14V Use Larger ire Size ISTANCE FT. (M.) FROM TRANSFORMER TO LAMPS FOR 300 ATT LOA IRE SIZE LESS TAN (Gauge) 10 (3.0) 10 (3.0) 20 (6.1) 30 (9.1) 40 (12.2) 50 (15.2) 60 (18.3) 70 (21.3) 80 (24.4) 90 (27.4) 100 (30.5) 110 (33.5) 120 (36.6) 12 13V 13V 14V Use Larger ire Size 10 13V 13V 14V 14V Use Larger ire Size 8 13V 13V 13V 14V 14V 14V Use Larger ire Size 6 13V 13V 13V 13V 14V 14V 14V 14V 14V ISTANCE FT. (Mt.) FROM TRANSFORMER TO LAMPS FOR 500 ATT LOA IRE SIZE LESS TAN (Gauge) 10 (3.0) 10 (3.0) 20 (6.1) 30 (9.1) 40 (12.2) 50 (15.2) 60 (18.3) 70 (21.3) 80 (24.4) 90 (27.4) 100 (30.5) 110 (33.5) 120 (36.6) 10 13V 14V 14V Use Larger ire Size 8 13V 13V 14V Use Larger ire Size 6 13V 13V 13V 14V 14V 14V Use Larger ire Size 4 13V 13V 13V 13V 14V 14V 14V 14V 14V 1 Suffix SL denotes primary cable entry from left side, low voltage right side. Suffix SR denotes primary cable entry from right side, low voltage left side. All units have auto-thermal reset. 2 Confirm tap selection by measurement of voltage at lamp terminals when all of the lamps are operating. 91

7 Low Voltage General Purpose Transformers FEATURES UL Listed, CSA Certified. 100, 150, 300, 600, 750, 1000 VA. 1 Phase, 60 z, 120 or 240 volt input. 12 or 24 volt output. Input Auto-Thermal reset switch. Output circuit breaker. Fully encapsulated core and coil. Full fault current carrying Faraday Shield. Flexible copper leadwire terminations. UL class 180 C insulation system 115 C rise. UL Type 2 enclosure. Keyhole slotted wall mounting brackets. Black finish. Bottom access. Two (2.2 cm) single knockouts each side. Two dual (2.2 cm) and (2.9 cm)knockouts on bottom cover. GROUP V 120 PRIMARY VOLTS 12 SECONARY VOLTS, TO ININGS, 1Ø, 60 z APPROX. IMENSIONS APPROX. VA CATALOG NO. Inches (Cm.) SIP EIGT CB RATING CB STYLE EIGT IT EPT Lbs. (Kg.) 100 T S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 15 AMP Push To Reset Thermal Breaker 150 T S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 20 AMP Push To Reset Thermal Breaker 300 T S (29.7) 4.66 (11.8) 4.57 (11.6) 11 (5.0) 40 AMP Push To Reset Thermal Breaker 600 T S (29.7) 4.66 (11.8) 4.57 (11.6) 15 (6.8) 60 AMP Magnetic Toggle On/Off Breaker 750 T S (29.7) 4.66 (11.8) 4.57 (11.6) 18 (8.2) 75 AMP Magnetic Toggle On/Off Breaker 1000 T S (30.3) 5.41 (13.7) 5.20 (13.2) 26 (11.8) 100 AMP Magnetic Toggle On/Off Breaker 120 PRIMARY VOLTS 24 SECONARY VOLTS, TO ININGS, 1Ø, 60 z APPROX. IMENSIONS APPROX. VA CATALOG NO. Inches (Cm.) SIP EIGT CB RATING CB STYLE EIGT IT EPT Lbs. (Kg.) 100 T S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 7 AMP Push To Reset Thermal Breaker 150 T S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 10 AMP Push To Reset Thermal Breaker 300 T S (29.7) 4.66 (11.8) 4.57 (11.6) 11 (5.0) 20 AMP Push To Reset Thermal Breaker 600 T S (29.7) 4.66 (11.8) 4.57 (11.6) 15 (6.8) 40 AMP Push To Reset Thermal Breaker 750 T S (29.7) 4.66 (11.8) 4.57 (11.6) 18 (8.2) 50 AMP Push To Reset Thermal Breaker 1000 T S (30.3) 5.41 (13.7) 5.20 (13.2) 26 (11.8) 50 AMP Magnetic Toggle On/Off Breaker 240 PRIMARY VOLTS 12 SECONARY VOLTS, TO ININGS, 1Ø, 60 z APPROX. IMENSIONS APPROX. VA CATALOG NO. Inches (Cm.) SIP EIGT CB RATING CB STYLE EIGT IT EPT Lbs. (Kg.) 100 T S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 15 AMP Push To Reset Thermal Breaker 150 T S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 20 AMP Push To Reset Thermal Breaker 300 T S (29.7) 4.66 (11.8) 4.57 (11.6) 11 (5.0) 40 AMP Push To Reset Thermal Breaker 600 T S (29.7) 4.66 (11.8) 4.57 (11.6) 15 (6.8) 60 AMP Magnetic Toggle On/Off Breaker 750 T S (29.7) 4.66 (11.8) 4.57 (11.6) 18 (8.2) 75 AMP Magnetic Toggle On/Off Breaker 1000 T S (30.3) 5.41 (13.7) 5.20 (13.2) 26 (11.8) 100 AMP Magnetic Toggle On/Off Breaker 240 PRIMARY VOLTS 24 SECONARY VOLTS, TO ININGS, 1Ø, 60 z APPROX. IMENSIONS APPROX. VA CATALOG NO. Inches (Cm.) SIP EIGT CB RATING CB STYLE EIGT IT EPT Lbs. (Kg.) 100 T S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 7 AMP Push To Reset Thermal Breaker 150 T S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 10 AMP Push To Reset Thermal Breaker 300 T S (29.7) 4.66 (11.8) 4.57 (11.6) 11 (5.0) 20 AMP Push To Reset Thermal Breaker 600 T S (29.7) 4.66 (11.8) 4.57 (11.6) 15 (6.8) 40 AMP Push To Reset Thermal Breaker 750 T S (29.7) 4.66 (11.8) 4.57 (11.6) 18 (8.2) 50 AMP Push To Reset Thermal Breaker 1000 T S (30.3) 5.41 (13.7) 5.20 (13.2) 26 (11.8) 50 AMP Magnetic Toggle On/Off Breaker 92

8 Buck- Boost Transformers The No-Frills Low Voltage Lighting Alternative Buck-Boost Transformers offer a no-frills approach to low voltage lighting. (See Chart Below) A typical Buck-Boost application is 120 volts in and 12 volts out for low voltage lighting or control circuitry. In most applications, this low voltage isolation transformer is field connected as an autotransformer. For more information on Buck-Boost Transformers, refer to the next section in this catalog. GROUP VI 120 x 240 VOLT INPUT 12/24 VOLT OUTPUT 1Ø, 60 z INSULATING SECONARY MAXIMUM APPROX. IMENSIONS APPROX. CATALOG TRANSFORMER Current Output Inches (Cm.) NET EIGT NUMBER RATING EIGT IT EPT Lbs. (Kg.) T KVA (16.2) 3.19 (8.1) 3.00 (7.6) 4 (1.8) T KVA (16.8) 3.75 (9.5) 3.62 (9.2) 5 (2.3) T KVA (18.1) 3.75 (9.5) 3.62 (9.2) 7 (3.2) T KVA (22.0) 4.08 (10.4) 3.88 (9.9) 10 (4.5) T KVA (23.0) 4.37 (11.1) 4.20 (10.7) 15 (6.8) T KVA (24.6) 4.75 (12.1) 4.51 (11.5) 19 (8.6) T KVA (26.7) 5.50 (14.0) 5.13 (13.0) 24 (10.9) T KVA (29.5) 5.50 (14.0) 5.13 (13.0) 30 (13.6) T KVA (33.0) 5.50 (14.0) 5.13 (13.0) 38 (17.2) T KVA (29.2) (26.2) 7.13 (18.1) 55 (24.9) T KVA (36.5) (26.2) 7.13 (18.1) 75 (34.0) T KVA (53.8) (34.3) (27.5) 125 (56.7) T KVA (53.8) (34.3) (27.5) 160 (72.6) Electrical Connection iagrams GROUP V GROUP VI 240V INPUT 4 3 INPUT 4 3 OUTPUT X4 OUTPUT X4 240V 240V INPUT V INPUT 4 3 OUTPUT X4 OUTPUT X4 93

9 VOLTAGE ROP CART Voltage Life Expectancy % of Rated at Lamp of Lamp Candlepower /3 Rated Life /4 Rated Life As Rated X Rated Life X Rated Life X Rated Life X Rated Life 50 CABLE SIZE CONSTANT CART Cable Cable Size Size Constant # # # # #10 11,920 #8 18,960 #6 30,150 VOLTAGE ROP FORMULA Total atts on Cable X Length of Run Cable Size Constant = Voltage rop 50' (15.2 m) A typical installation showing three separate runs on a 300 Power Supply 80' (24.4 m) 100' (30.5 m) 12/2 ire Low Voltage Lighting Layout Grid 300 POER SUPPLY 12/2 ire 94

General Purpose Buck - Boost Wiring Diagrams... 86

General Purpose Buck - Boost Wiring Diagrams... 86 SECTION LOW VOLTAGE/ LIGHTING TRANSFORMERS General Purpose... 84 Buck - Boost... 85 Wiring Diagrams... 8 LOW VOLTAGE LIGHTING TRANSFORMERS & POWER SUPPLIES Low Voltage Lighting A greater selection for

More information

Planning Low Voltage Layouts

Planning Low Voltage Layouts Outdoor_ransformers_Outdoor_ransformers.qxd 11-11-10 3:40 PM Page 1 1850 Wilson Avenue, oronto, Ontario, anada, M9M 1A1 Ph: 416-741-7336 Fax: 416-741-9104 SEION H OUDOOR H1 OUDOOR Low Voltage ransformers

More information

SPECIFICATION SHEET. Transformers. Cable cord: Core: Timers & Photocell: Wire Rating: Certification: Warranty: OFF. Bottom mounting slot Front View

SPECIFICATION SHEET. Transformers. Cable cord: Core: Timers & Photocell: Wire Rating: Certification: Warranty: OFF. Bottom mounting slot Front View 9 7 0 7 9 SPECIFICAION SHEE 6 Staunton Ave EL. PRODUC # : -R600 (Multi-tap) ransformer Specifications: Enclosure: op grade 0 stainless steel, NEMA R Electrical Characteristics: Wattage: Primary Voltage:

More information

Features, Benefits and Functions

Features, Benefits and Functions -8 Buck-Boost and Lighting Single- and Three-Phase February 007 Single- and Three-Phase Applications, 60 Hz Type EP Product Description Types EP, EPT Sand and Resin Encapsulated design. Suitable for indoor

More information

HPS Fusion General Purpose Enclosed Transformer

HPS Fusion General Purpose Enclosed Transformer HPS Fusion General Purpose Enclosed Transformer Our Company Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the short wave radio

More information

Approx. Net Frame Product Input Voltage Output Voltage kva Height (in) Width (in) Depth (in) Weight (Lbs.) Size Number

Approx. Net Frame Product Input Voltage Output Voltage kva Height (in) Width (in) Depth (in) Weight (Lbs.) Size Number Buck-Boost Single-Phase Indoor/Outdoor Type QB 60 Hz UL Listed C-UL Listed Approx. Net Frame Product Input Voltage Output Voltage kva Height (in) Width (in) Depth (in) Weight (Lbs.) Size Number 120/240

More information

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits. Class I Division 2 10 1 to 25 kva Applications n Class I Division 2 units are used in hazardous locations to maintain a safe environment. Specifications n Class I Division 2, Groups A, B, C, D n T3C temperature

More information

Single-Phase Ventilated

Single-Phase Ventilated Single-Phase Ventilated 1 15 to 1,650 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency

More information

Midwest Dry Type Transformers

Midwest Dry Type Transformers Midwest Electric Products Midwest Dry Type Transformers Reliable and Efficient Performance From a Name You Know DOE 2016 Efficiency Transformers Catalog General Information...2 General Purpose... 3 Single-Phase

More information

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers

More information

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers Type FEC Epoxy Encapsulated, Copper-Wound Transformers ISO 900:2008 REGISTERED 0 Transformer Selector Guide Type FEC Transformers...Page 02 Primary Fusing Option...Page 07 Primary Overcurrent Selection...Page

More information

Transformers 6. Gross Automation (877)

Transformers 6. Gross Automation (877) Transformers 6 Hevi-Duty Family of Transformers Sola/Hevi-Duty offers a broad range of transformers to meet many applications. These dry-type transformers are offered encapsulated, ventilated or non-ventilated,

More information

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS Hammond Power Solutions Inc. Page 1 of 1 ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS HPS Titan has been designed to operate in harsh environments/hazardous locations where dangerous gases, liquids,

More information

Wiring Diagram Number

Wiring Diagram Number General-Purpose Encapsulated Transformers.4 Single-Phase Encapsulated Type EP, 60 Hz 77 Volts to 10/40 Volts 1 Full Capacity Taps kva FCAN FCBN Type 40 x 40 Volts to 10/40 Volts Full Capacity Taps kva

More information

TA Ta VA CTRL-XFRMR

TA Ta VA CTRL-XFRMR 3804 South Street 7964-7263, TX Nacogdoches Phone: 936-69-7941 Fax: 936-60-468 TA2437 Ta-2-437 10VA CTRL-XFRMR Acme Electric Catalog Number TA2437 Manufacturer Acme Electric Description Control Transformer,

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

JUNCTION / DECK BOX. - Made of white ABS and push in cover with O-ring seal IP 55 weather protection.

JUNCTION / DECK BOX. - Made of white ABS and push in cover with O-ring seal IP 55 weather protection. JUNCTION / DECK BOX - Made of white ABS and push in cover with O-ring seal IP 55 weather protection. - Supplied with a set of electric connectors and threaded couplers. - It has 3 threaded outlets of 3/4

More information

B BASIC HEAT TREATMENT CONSOLE

B BASIC HEAT TREATMENT CONSOLE Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL

More information

Dry-Type Transformers Mini-Power Centers

Dry-Type Transformers Mini-Power Centers Dry-Type Transformers Mini-Power Centers Product Focus Three individual components combined into a single unit to save space and costs, 3 to 30 kva Dry-Type Transformers Mini-Power Centers Significant

More information

Three-Phase Ventilated

Three-Phase Ventilated Three-Phase Ventilated 2 15 to 2,500 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency

More information

New dimming drivers are compatible with most wall dimmers for % light control. For non-dimming

New dimming drivers are compatible with most wall dimmers for % light control. For non-dimming CONSTANT VOLTAGE POWER SUPPLIES CONSTANT VOLTAGE New dimming drivers are compatible with most wall dimmers for 10-100% light control. For non-dimming applications or for use with AL-PWM-6A, use LED-DR

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

OUTPUT CONNECTIONS Bring the wires of the light fixture through the other open knockout and connect them to the power supply output wires.

OUTPUT CONNECTIONS Bring the wires of the light fixture through the other open knockout and connect them to the power supply output wires. MAGNETIC SUPPLY INSTALLATION SAFETY GUIDE Please read before installing. GENERAL This power supply is to be installed in accordance with Article 450 of the National Electric Code. The power supply must

More information

Totally Enclosed Non-Ventilated

Totally Enclosed Non-Ventilated 5 15 to 500 kva 5 Applications n Designed for commercial and industrial loads in challenging environments Specifications n NEMA3R rated enclosure n Single Phase units 15 through 100 kva n Three Phase units

More information

LOW-VOLTAGE TRANSFORMER INSTALLATION GUIDE. Models: VTR-100SL-SS, VTR-150SL-SS, & VTR-300SL-SS

LOW-VOLTAGE TRANSFORMER INSTALLATION GUIDE. Models: VTR-100SL-SS, VTR-150SL-SS, & VTR-300SL-SS LOW-VOLTAGE TRANSFORMER INSTALLATION GUIDE Models: VTR-100SL-SS, VTR-150SL-SS, & VTR-300SL-SS ATTENTION: Please read this installation guide carefully to ensure safe and efficient operation of this Power

More information

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality Individual & fixed capacitor banks Low Voltage L O W V O L T A G E N E T W O R K Q U A L I T Y Individual & fixed bank Capacitors Description High reliability Well proven features of ABB dry type power

More information

M-SERIES MAGNITUDE LIGHTING MAGNETIC DIMMABLE CLASS 2 LED DRIVER QUICK SPECS ENCLOSURE DETAILS

M-SERIES MAGNITUDE LIGHTING MAGNETIC DIMMABLE CLASS 2 LED DRIVER QUICK SPECS ENCLOSURE DETAILS MAGNITUDE LIGHTING C DIMMABLE DIM DOWN TO 1% CLASS 2 12V DC P/N: M20L12DC-AR Magnitude's M20L12DC-AR is the most compact LED driver on the market with a magnetic transformer core. It is equipped with two

More information

DLTC. lighting controls. transfer circuit for use with low-voltage down-lighting. features

DLTC. lighting controls. transfer circuit for use with low-voltage down-lighting. features LT transfer circuit for use with low-voltage down-lighting Two channel device providing switching for up to 75 watts per channel ombines existing low-voltage lighting with a 12 volt emergency unit power

More information

Installation Manual CS9300-LED. Professional Series Landscape Lighting System

Installation Manual CS9300-LED. Professional Series Landscape Lighting System Installation Manual CS9300-LED Professional Series Landscape Lighting System CS9300 Professional Series LED Landscape Lighting System pg. 1 READ THESE INSTRUCTIONS ENTIRELY BEFORE BEGINNING INSTALLATION!

More information

50 Hz Mini/Micro Computer Regulator (MCR) Series Installation and Operation Manual

50 Hz Mini/Micro Computer Regulator (MCR) Series Installation and Operation Manual Operating & Service Instructions Sola Minicomputer Regulators UL White Card Listed Power Supply Classification CSA Certified Transformer Classification General Description and Specifications The Sola Micro/Minicomputer

More information

MLT T-RPC. Supplied with mounting plate & hardware for easy installation (key slotted back)

MLT T-RPC. Supplied with mounting plate & hardware for easy installation (key slotted back) M 000 Stainless Steel - Weatherproof Transformers WHY USE M 000 KITS? 1. Modular design enables fast and easy field upgrades. Add or remove any control device in minutes. No down time!. Transformer never

More information

Individual & fixed bank capacitors

Individual & fixed bank capacitors Individual & fixed bank capacitors L O W V O L T A G E N E T W O R K Q U A L I T Y Description High reliability Well proven features of ABB dry type power factor cor rection capacitor tech nology are incorporated

More information

Electrical Design/Build Guide

Electrical Design/Build Guide 2017 Electrical Design/Build Guide Based on the 2017 National Electrical Code Copyright Durand & Associates 1986-2016 60 C Copper Ampacity 4 - Wire Fill - (Non-Current Carrying Neutral) 4 or 5 - Parallel

More information

INSTALLATION INSTRUCTION Magnetic Transformer

INSTALLATION INSTRUCTION Magnetic Transformer IMPORTANT: Read all instructions before installing. Read all instructions before proceeding with the installation. This power supply complies with the requirements of UL1838. This power supply should be

More information

OUTDOOR TRACK. LABELS Assembled in America

OUTDOOR TRACK. LABELS Assembled in America OUTDOOR TRACK DESIGNED BY GREGORY KAY PATENT-PENDING FEATURES & BENEFITS Offers the flexibility of 2-Circuit Track Lighting in an exterior environment Uses 12VAC low voltage wiring without the need for

More information

SURE TRIP RETRO KITS

SURE TRIP RETRO KITS RMS CURRENT MEASUREMENT with SURE TRIP RETRO KITS Circuit Breaker Solid State Controls with SURE TRIP LOGIC The Sure Trip Solid State Tripping Systems Have Been Designed, Tested And Produced To all Applicable

More information

HIGH INTENSITY DISCHARGE BALLASTS

HIGH INTENSITY DISCHARGE BALLASTS Philips Advance ballasts are available to operate the wide variety of metal halide, high pressure sodium and low pressure sodium lamps available in today s marketplace. Like fluorescent, lamps are gas

More information

Industrial Control Power Transformers Class MT

Industrial Control Power Transformers Class MT Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments

More information

diode led 24VDC MAGNETIC DIMMABLE DRIVER SPECIFICATION SHEET 24VDC OVERVIEW FEATURES

diode led 24VDC MAGNETIC DIMMABLE DRIVER SPECIFICATION SHEET 24VDC OVERVIEW FEATURES diode led a division of elemental LED 24VDC MAGNETIC DIMMABLE DRIVER 24VDC WET LOCATION DIMMABLE SPECIFICATION SHEET OVERVIEW 24VDC Magnetic Dimmable Drivers are perfect for supplying low voltage power

More information

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER Important The BBC -3140 must be used according to the local safety standards with the particular application. All wiring and connections

More information

Recreational Vehicle Park Electrical Products & Accessories

Recreational Vehicle Park Electrical Products & Accessories Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information

Distribution Dry Type Transformers 600 Volts Class Single and Three Phase Selection

Distribution Dry Type Transformers 600 Volts Class Single and Three Phase Selection 7 Distribution Dry Type Transformers 600 Volts Class Single and Three Phase 600 Volts Class Single Phase 0.25 167 KVA Three Phase 3 1000 KVA Features Standard units are UL listed and are designed in accordance

More information

3. Coils shall be of molded construction

3. Coils shall be of molded construction .7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application

More information

Transformer Disconnects

Transformer Disconnects Catalog April 05 Class 9070 CONTENTS Description..............................................Page Introduction................................................. 3 Standard Features............................................

More information

Installation Manual. CS9300 Professional Series Landscape Lighting System

Installation Manual. CS9300 Professional Series Landscape Lighting System Installation Manual CS9300 Professional Series Landscape Lighting System CS9300 Professional Series Landscape Lighting System pg. 1 READ THESE INSTRUCTIONS ENTIRELY BEFORE BEGINNING INSTALLATION! Congratulations

More information

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring User Manual JS-ICON 624 ARCH Dimmer Rack JOHNSON SYSTEMS INC. Spring 2007 2002161 Table of Contents JS-ICON 624 DMX JS-ICON 624 CC 6-2.4kW Dimming Strip JS-ICON 624 ND 6-2.4kW Relay Strip Introduction...3

More information

Installation Manual CS9100-LED. Professional Series Landscape Lighting System

Installation Manual CS9100-LED. Professional Series Landscape Lighting System Installation Manual CS9100-LED Professional Series Landscape Lighting System LED Landscape Lighting System pg. 1 READ THESE INSTRUCTIONS ENTIRELY BEFORE BEGINNING INSTALLATION! Congratulations on your

More information

Enclosures. See Section Typical Description

Enclosures. See Section Typical Description January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic

More information

4" Motors and Controls

4 Motors and Controls 4" Motors and Controls BRCP4MTR R1 4" CENTRIPRO MOTOR SINGLE-PHASE MOTORS: Two-Wire PSC Motors ½ HP, 115 V ½ - 1½ HP, 230 V Three-Wire Motors ½ HP, 115 V ½ - 5 HP, 230 V THREE-PHASE MOTORS: ½ - 10 HP (10

More information

LED Auxiliary Devices

LED Auxiliary Devices LED Auxiliary Devices 30 YEARS OF EXCELLENCE 1985-2015 Incorporated in the state of California in 1985, McWong International, Inc. has grown to become a strategic supplier of high-quality lighting control

More information

BF Series Flasher Thermal flasher circuitry

BF Series Flasher Thermal flasher circuitry BF Series Flasher Thermal flasher circuitry Long life 2A load rating @ 115V AC Low cost Small size All units work on AC and DC input voltage 3 terminal configuration 6V to 115V input voltages available

More information

REVISIONS App PC. App Sud. App Thom TC 2014/03/25

REVISIONS App PC. App Sud. App Thom TC 2014/03/25 /9 Rev Description Document format and number changed. Previous number 543-0.0.30 Rev n by TC 204/03/25 Sud TC 204/03/25 REVISIONS PC Thom VB LH Clyd r Act Issue Date YYYY/MM/DD Pending Pending Pending

More information

SURE-TRIP OEM RELACEMENT TRIP UNIT

SURE-TRIP OEM RELACEMENT TRIP UNIT RMS CURRENT MEASUREMENT with SURE-TRIP OEM RELACEMENT TRIP UNIT Update Circuit Breaker Solid State Controls with SURE-TRIP LOGIC The SURE-TRIP Solid State Tripping Systems Have Been Designed, Tested And

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60 TECHNICAL GUIDE GUARDIAN SERIES DRY SHIP AIR CONDITIONER CONDENSING UNITS SHIPPED WITH NITROGEN CHARGE ONLY 13 SEER R-22 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: GCGD18 THRU 60 UARDIAN Due to continuous

More information

Tanning Bed Transformers

Tanning Bed Transformers Tanning Bed Transformers Complete line of transformers designed specifically for the tanning industry. SolarTran Tanning Bed Transformers are specifically designed to serve the voltage transformation needs

More information

MODEL 422 Submersible Pump Controller

MODEL 422 Submersible Pump Controller MODEL 422 Submersible Pump Controller Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or 240VAC, Single-phase or 3-phase Built-in Trip and

More information

Three Phase Transformers

Three Phase Transformers Three Phase Transformers ontents Three Phase - General Purpose... 26 Three Phase - General Purpose Scott ed... 30 Three Phase - dditional ombinations vailable... 31 Three Phase - ion Diagrams... 32 Series

More information

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment. General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail

More information

Non-Ventilated Automation Transformers 6

Non-Ventilated Automation Transformers 6 Non-Ventilated Automation Transformers 6 Automation Transformers - Non-Ventilated 50 VA to 45 SolaHD encapsulated transformers are rated for Hazardous Locations (Class 1, Division 2, Group A-D) as well

More information

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS Security Door Controls & Door Controllers 5 SDC Access Control Power Supplies have been developed specifically to support access controls and electric locking hardware with clean, consistent power. Combined

More information

SPEQ -S. Small Cylinder Track Head

SPEQ -S. Small Cylinder Track Head SPEQ -S Features esigned to let the interior design and not the lighting take center stage, the SPEQ track head from Amerlux balances clean, minimal aesthetic design with industry leading optical performance.

More information

Modifiable TITAN Horizontal Motors Accessories and Modifications

Modifiable TITAN Horizontal Motors Accessories and Modifications 36. Rotor, Standard And Optional Construction Standard rotor construction of 449, 5000 and 5800 frame TITAN products is typically die-cast aluminum. 720 RPM and slower is typically fabricated aluminum.

More information

Industrial Control Power Transformers

Industrial Control Power Transformers 09/10/15 Class MT Features b Enclosed coils (50-5000); Completely encloses the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial

More information

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

Product guide. Enclosed NEMA starters. usa.siemens.com/controls Product guide Enclosed NEMA starters usa.siemens.com/controls The right choice for applications that demand the best Siemens NEMA combination and non-combination starters for industrial and construction

More information

BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS

BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS FEATURES NEMA 3R Enclosure: Rainproof, outdoor/ indoor rated enclosure. Current

More information

112.5 kva Transformer Delta Primary - 240/120V Secondary - 60 Hz - 3 Phase - NEMA 3R

112.5 kva Transformer Delta Primary - 240/120V Secondary - 60 Hz - 3 Phase - NEMA 3R 112.5 kva Transformer 480 Delta Primary 240/120V Secondary 60 Hz 3 Phase NEMA 3R Part #: MT112.5KVA480240.1203P Page: 1 The MT112.5KVA480240.1203P 480D 3 Phase Energy Efficient isolation transformer from

More information

AUXILIARY ELECTRIC HEATER KITS FOR 7.5, 10, 15 AND 20 TON COMMERCIAL AIR HANDLERS RXHE-CE, DE

AUXILIARY ELECTRIC HEATER KITS FOR 7.5, 10, 15 AND 20 TON COMMERCIAL AIR HANDLERS RXHE-CE, DE AUXILIARY ELECTRIC HEATER KITS FOR 7., 10, 1 AND 20 TON COMMERCIAL AIR HANDLERS RXHE-CE, DE WARNING: THIS ACCESSORY IS TO BE INSTALLED BY A QUALIFIED, LICENSED SERVICE PERSON. TO AVOID UN - SATISFACTORY

More information

Electromagnetic Fluorescent Ballasts

Electromagnetic Fluorescent Ballasts Ballasts alco ighting Technologies offers Proume Ballasts for standard T1 applications, including Preheat, Rapid Start, Rapid Start igh Output and Instant Start ballasts. inimum Starting Temperature Proume

More information

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium

More information

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter pool lighting The Treo Micro LED light is 12VAC, 2 Watt LED underwater light designed for accent Available in lengths of 30, 50, 80', 150 50,000 hour lamp life No Earth bonding required White or color

More information

Q-VAULT Installation Instructions. Q-Tran, Inc. Milford, CT

Q-VAULT Installation Instructions. Q-Tran, Inc. Milford, CT QVAULT Installation Instructions QTran, Inc. Milford, CT www.qtran.com QVAULT 342694 Luminairs Landscape Lighting Systems Certified to UL 1838 Standard. 342595 Luminairs Low Voltage Lighting Systems Certified

More information

Dry Type Distribution Transformers

Dry Type Distribution Transformers Automation Transformers - Non-Ventilated 50 VA to 45 SolaHD encapsulated transformers are rated for Hazardous Locations as well as harsh industrial environments. Encapsulation and rugged UL Listed/NEMA

More information

PH250MQMJ CNTL 250VA 240X X240

PH250MQMJ CNTL 250VA 240X X240 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 PH250MQMJ CNTL 250VA 240X480-120X240 Hammond Power Solutions Catalog Number Manufacturer Description Weight per unit Product

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................

More information

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

1/6 through 5 HP Adjustable Speed, DC Motor Controllers 1/6 through 5 HP Adjustable Speed, DC Motor Controllers 1/6-5 HP 115 or 230 V, Single Phase - Reconnectable Four Quadrant Regenerative Selectable Deadband AC Line Starting DC Tachometer Feedback Run Contact

More information

EPS-ECONOMY PUMP STARTER

EPS-ECONOMY PUMP STARTER EPS-ECONOMY PUMP STARTER 1 & 3 Phase, 50/60Z, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides a simple and dependable starting option with a wide electronic overload

More information

Product guide. Enclosed NEMA starters. Answers for industry.

Product guide. Enclosed NEMA starters. Answers for industry. Product guide Enclosed NEMA starters Answers for industry. The right choice for applications that demand the best Siemens NEMA combination and non-combination starters for industrial and construction applications

More information

Softstarters Type PSS. Softstarters. General information

Softstarters Type PSS. Softstarters. General information General information The PSS Softstarter line brings a wide array of benefits for smaller motors in a flexible, compact form. The PSS "Flexible" Softstarter line PSS18/30 to PSS300/515 softstarters provide

More information

FORM NO. HSC-543 AIR HANDLERS

FORM NO. HSC-543 AIR HANDLERS FORM NO. HSC- AIR HANDLERS AH10X1 High Efficiency featuring New Industry Standard R-10A Refrigerant Features AH10X1 features the new X-1 (ECM) motor which provides enhanced SEER performance with most Sure

More information

MIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6

MIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6 I. PART 1 GENERAL 1. SCOPE A. NEMA Premium copper-wound ultra low loss isolation transformer with a higher efficiency than that required by NEMA Std. TP-1. Optimized for energy efficiency over a wide load

More information

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output 3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output MODEL NUMBER: RV3012OEM Description Tripp Lite's RV3012OEM Inverter/Charger is the quiet alternative to gas generators with no fumes, fuel

More information

Dry Type Distribution Transformers

Dry Type Distribution Transformers Selection Steps A. Use the following steps below to manually select a transformer. B. Find the electrical load requirements. These are: 1. Load operating voltage. 2. Load frequency (expressed in Hz). 3.

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................

More information

SELECTRIC, INC. Selectric (PA) Autotransformer Type Motor Control Panel Installation And Operation Manual

SELECTRIC, INC. Selectric (PA) Autotransformer Type Motor Control Panel Installation And Operation Manual SELECTRIC, INC. Selectric (PA) Autotransformer Type Motor Control Panel Installation And Operation Manual Table of Contents I. Description of Equipment Page 3 II. Description of Operation 3 III. Installation

More information

Product Guide. enclosed NEMA STARTERS

Product Guide. enclosed NEMA STARTERS Product Guide enclosed NEMA STARTERS The Right Choice for Applications that Demand the Best. Siemens NEMA Combination and Non- Combination Starters for Industrial and Construction Applications Rugged,

More information

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications Product Description Product Description The Mini Power-Zone Unit Substation from Schneider Electric is a miniaturized version of our Power-Zone Unit Substation. Included are: Circuit Breaker Sealed Step-Down

More information

Ballasts For High Intensity Discharge Lamps

Ballasts For High Intensity Discharge Lamps allasts For High Intensity Discharge Lamps Universal Means Higher Expectations In High Intensity Discharge Universal Lighting Technologies ( Universal ) offers a wide array of ballasts for High Intensity

More information

Dry Type Distribution Transformers

Dry Type Distribution Transformers Automation Transformers - Non-Ventilated 50 VA to 45 SolaHD encapsulated transformers are rated for hazardous locations as well as harsh industrial environments. Encapsulation and rugged UL Listed/NEMA

More information

Bulletin 1497A Machine Tool Transformers

Bulletin 1497A Machine Tool Transformers Bulletin A Overview/Catalog Number Explanation Bulletin A Bulletin A are designed to reduce supply voltages to control circuits. The complete line of transformers is available with optional factory-installed

More information

HPS Fusion General Purpose Enclosed Transformer

HPS Fusion General Purpose Enclosed Transformer HPS Fusion General Purpose Enclosed Transformer Our Company Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the short wave radio

More information

Control Circuit Transformers

Control Circuit Transformers Technical Data Control Circuit Transformers Bulletin Numbers 1497, 1497A, 1497B, 1497D Topic Page Summary of Changes 1 Control Circuit Transformers Product Overview 2 Bulletin 1497 Global Control Circuit

More information

Typical Applications. Horizontal Installation

Typical Applications. Horizontal Installation ENGINEERING DATA COILS COIL UNITS CB19 AND CBH19 SERIES UP-FLOW, DOWN-FLOW AND HORIZONTAL COIL UNITS *12,600 to 65,500 Btuh (3.7 to 19.2 kw) Cooling Capacity 11,500 to 60,000 Btuh (3.4 to 17.6 kw) Heat

More information

AFL FLOODLIGHT SERIES

AFL FLOODLIGHT SERIES AFL FLOODLIGHT SERIES A FL Flood Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C & D UL 844 Hazardous Locations UL 598A Marine Outside Type Zone 2, Groups IIA, IIB & IIC CUL Cast Aluminum

More information

Single-Phase Step Voltage Regulators

Single-Phase Step Voltage Regulators Voltage Regulators Catalog Data CA225001EN Supersedes March 2017 COOPER POWER SERIES Single-Phase Step Voltage Regulators Contents GENERAL....2 STANDARD FEATURES....4 OPTIONAL ACCESSORIES...4 ARRESTERS....4

More information

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS 1 Catalog KM-MCD-0818A Replaces KM-CSA-101A, KM-DSA-101A, KM-MSA-1213A, KM-CSE-101A and KM-MSE-101A DSA, CSA, MSA, CSE, AND MSE SERIES MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS MEDIUM

More information

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH 331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing

More information

Dry Type Distribution Transformers

Dry Type Distribution Transformers Dry Type Distribution Transformers 5 General Purpose Energy efficient dry-type transformers 600 Volt Class, isolation type, single and three phase, 15 through 500. Indoor and outdoor models available.

More information

IEC Utilization Categories (Explanation)

IEC Utilization Categories (Explanation) IEC Utilization Categories (Explanation) IEC Utilization Categories Voltage Category Typical Applications A.C. A.C. and D.C. D.C. AC AC AC AC ACa ACb AC6a AC6b AC7a AC7b AC8a AC8b AC AC AC AC AC AC AC

More information

Pretest Module 24 Three-phase Service Entrance

Pretest Module 24 Three-phase Service Entrance Pretest Module 24 Three-phase Service Entrance 1. What is the most widely used three-phase service entrance system? 2. What are the three most common voltage combinations for three-phase, four-wire systems?

More information