Control Transformers

Size: px
Start display at page:

Download "Control Transformers"

Transcription

1 ontrol Transformers HPS Imperator TM, QE, MV Series Industrial ontrol Transformers ontrol Transformer Quick Selection harts... 0 What Is A ontrol Transformer?... ontrol Transformer Selection Guide... HPS Imperator ontrol Transformers... HPS Imperator Features & enefits... - HPS Imperator Selection Tables HPS Imperator Overcurrent Protection... 7 Fuse Kits... 9 s... 0 HPS Imperator Accessory Installation Guide... HPS Imperator Wiring Schematics Q Series Enclosed Potted ontrol Transformers... 6 Q Series Selection harts... 6 MV Series Medium Voltage ontrol Transformers... 6 MV Series Dimensional Drawings and Fuse Kit... 66

2 INDUSTRIAL ONTROL TRANSFORMERS HPS IMPERATOR TM ONTROL TRANSFORMER QUIK SELETION HARTS HPS Imperator Series Pri. Volts Sec. Volts Group Part No. Page 600, 7, 0 0x0, x0, 0x0 A PH***AJ 6 600, 7, 0 x,.x, x PH***AR 7 0x80, 0x60, 0x0 0x0, x0, 0x0 PH***MQMJ 8 0x80, 0x60, 0x0 x,.x, x D PH***QR 9 08x6, 00x00, 90x80 0x0, x0, 0x0 E PH***SP 0 0x0, x0, 0x0 0x0, x0, 0x0 F PH***PP 0x0, x0, 0x0 x,.x, x G PH***PG 600/80/0, 7/60/0, 0/0/0 0/00, /9, 0/90 H PH***MMH 80/0, 60/0/08, 0/0/00 0/, /, 0/ I PH***MLI /00/80 0x0 J PH***MEMX 80/77/08 0x0 K PH***MGJ 6 MV Series Q Series Pri. Volts Sec. Volts Part No. Page 00 0/0 MV***RE /0 MV***QE /0 MV***SE /0 MV***TE /0 MV***UE /0 MV***VE 6 Pri. Volts Sec. Volts Part No. Page 600 0/0 Q**9P / Q***PR* 6 0/80 0/0 Q**6P 6 0

3 SETION 9 HPS IMPERATOR TM WHAT IS A ONTROL TRANSFORMER? What is a ontrol Transformer? A control transformer is an isolation transformer designed to provide a high degree of secondary voltage stability (regulation) during a brief period of overload condition (also referred to as inrush current ). ontrol transformers are also known as Machine Tool Transformers, Industrial ontrol Transformers or ontrol Power Transformers. When you calculate the VA requirement of a Transformer, do you use the Primary or the Secondary Voltage? When selecting the VA requirement, you use the Secondary Voltage. an you use a ontrol Transformer connected in reverse? Yes, a control transformer can be connected in reverse. However, keep in mind the output voltage will be less than its rating, due to the compensation factor of the windings. an a ontrol Transformer regulate the output voltage? A control transformer will not regulate the voltage. Output voltage is a function of the coil s turn ratio only, times the input voltage. What is the benefit of Vacuum Impregnation on a Transformer? All HPS ontrol Transformers are vacuum impregnated VT Polyester Resin and oven cured which seals the surface and eliminates moisture. Impregnating the entire unit provides a strong mechanical bond and offers protection from environmental conditions. Explain the VA or Volt Ampere Output Rating? The VA or volt ampere output rating designates the output which a transformer can deliver for a specified time at its rated secondary voltage and rated frequency, out exceeding its specified temperature rise. Insulating Materials; what are they made of and what is their purpose? Hammond Power Solutions utilizes Mylar, Nomex and other high quality insulating materials. Insulation is used to electrically insulate turn-to-turn windings, layer-to-layer windings, primary to secondary windings and ground. What is the effect of Overload? When a transformer is continually overloaded, excessive heat develops and the insulation system will begin to breakdown. As a result, the life expectancy of the transformer is shortened due to the heat exceeding the rating of the insulation system.

4 INDUSTRIAL ONTROL TRANSFORMERS ONTROL TRANSFORMER SELETION Selecting a ontrol Transformer requires that you have first hand knowledge of the application for the transformer and that you understand some basic terms related to the selection process. y using the following information, you will be sure to select the HPS ontrol Transformer which best meets your application. The HPS Imperator Series machine tool control transformers are specifically designed for high inrush applications requiring reliable output voltage stability. Designed to meet industrial applications where electromagnetic devices such as relays, solenoids, etc. are used, the HPS Imperator series transformers maximize inrush capability and output voltage regulation when electromagnetic devices are initially energized. To select the proper transformer, three characteristics of the load circuit must first be determined. They are total steady-state (sealed) VA, total inrush VA, and inrush load power factor. (A). The total steady state sealed VA is the amount of VA that the transformer must supply to the load circuit for an extended length of time. Simply add the total steady-state VA of all devices in your control circuit. The operating VA data of these components is available from the manufacturers. (). The total inrush VA is the amount of VA that the transformer must supply for all components in the control circuit which are energized together. Some consideration to the start-up sequence may be required. Inrush VA should be obtained from the device manufacturer. (). The inrush load power factor is difficult to determine out detailed vector analysis of all the control circuit components. Such information is not generally available. Therefore, HPS is recommending that a value of 0% power factor be utilized. Although some other control transformer manufacturers still recommend a power factor of only 0%, HPS, through recent tests conducted on many popular brands of control devices, has determined that the 0% power factor value is more accurate. Once the above circuit variables have been determined, transformer selection is a six step process. SIX EASY STEPS. Determine what your Primary (supply) and Secondary (output) voltage requirements are, as well as your required frequency (i.e. 60 Hz). alculate the Total Sealed VA of your circuit. (See Step A). Now calculate the Inrush VA by adding the inrush VA of all components being energized together. Remember to add the sealed VA of all components that do not have inrush VA, (lamps, timers etc.) as they do, however, present a load to the transformer during maximum inrush. If the inrush for the components in your circuit are not known, assume a 0% Inrush Power Factor.. alculate the Total Inrush VA using one of the two methods: A. Total Inrush VA = (VA sealed) + (VA inrush) OR. Total Inrush VA = VA Sealed + VA Inrush Note: method will result in a slightly larger transformer being selected. For VA sealed definition please refer to (A). For VA inrush definition please refer to ().. If the nominal supply voltage does not fluctuate more than %, then reference the 90% secondary voltage column in the Regulation Data Table for the correct VA rating. If the supply voltage varies upwards of 0%, the 9% secondary voltage column should be used to size the transformer. urrent standards require electromagnetic devices to operate reliably at a minimum of 8% of their rated voltage. However, contact life may be affected continuous start-ups at that voltage level. Therefore, the minimum 8% secondary voltage column should only be used as a reference. 6. Using the regulation data tables below, select the appropriate VA rated transformer: A) With a continuous VA rating that is equal to or greater than the value in Step. ) With a maximum inrush VA equal to or greater than the value obtained in Step. To determine the correct HPS Transformer and its atalog Number, just refer to the tables in this catalog for the voltage ratings, frequency and corresponding VA required. HPS IMPERATOR TRANSFORMERS REGULATION DATA TALE ontinuous VA Inrush 0% Power Factor Transformer 8% 90% 9% Nameplate Secondary Secondary Secondary Rating Voltage Voltage Voltage It is recommended that a ontrol Transformer be sized at a 0% Power Factor. Some components in a circuit, such as electromagnetic devices, typically operate at that level due to their inherently lower power factor. Selecting a transformer at 0% Power Factor will more than adequately size the unit for all the various loads in the circuit.

5 SETION 9 HPS IMPERATOR TM HPS Imperator TM Series ontrol Transformer - Applications The Perfect Solution Innovative Design The HPS Imperator series of machine tool industrial control transformers are specifically designed to meet the high inrush industrial applications where electromagnetic components such as relays, solenoids etc. are used. With standard voltage groups, a VA range from 0VA to 000VA and available standard secondary and optional primary fuse kits, the HPS Imperator series from HPS provides the perfect solution for any applications. Superior Quality and Value The HPS Imperator series is a unique, fresh and innovative compact design that provides the ideal solution for any industrial control application and will change the way the industrial machine tool industry looks at the control transformer. The HPS Imperator s unique terminal block design (patent pending) allows for the quick and easy installation of standard secondary or optional primary / x / midget/type fuse clips on every unit. This is the simplest and most inexpensive fusing installation provided on any industrial control transformer in the market today. The HPS Imperator series design, utilizing superior insulation systems and being constructed high quality silicon steel laminations for optimum performance, will meet or exceed UL and E standards. acked by an industry leading LIFETIME warranty, the HPS Imperator industrial control transformer line offers superior performance, quality and value. The windings and internal terminations of the HPS Imperator are encapsulated, which protects them from moisture, dirt and other airborne contaminants. The custom molded coil covers their unique fin shaped design combine superior transformer cooling properties a clean bold look. The HPS Imperator utilizes custom serrated terminals, in combination standard SEMS washer screws making assembly easier and quicker to install; and provides superior connection strength when connecting bare, solid or stranded wire. It also allows for ring or spade termination connectors. STANDARDS HPS Industrial and Machine Tool ontrol and Instrument Transformers meet or exceeds the standards established by UL, IR, ANSI, NEMA. Standard File # VA Size UL (ANSI/UL 06) E09 All PH IE 68 NEMA (ST-) All PH (excluding PH***AJ & PH***AR) All PH At HPS, we rate the VA capacity of our transformers at the output... where it counts. Other transformer manufacturers rate their capacity on the input side of the transformer, which can result in a % to 0% lower actual VA at the output.

6 HPS IMPERATOR TM Features & enefits 600V class, machine tool rated industrial control transformers standard multi primary and secondary voltage groups available 0/60 Hertz (60Hz on PH***AJ & PH***AR) VA range from 0 to 000 Superior insulation system 0-0VA, temperature rise, insulation class VA, temperature rise 80, insulation class VA, temperature rise, insulation class 80 onstructed high quality silicon steel laminations that provide optimum performance and reliability Encapsulated coils (up to and including 00VA) encased in a custom injection molded cover, protects coils and terminations from moisture, dirt and other industrial airborne contaminants. Feet: made of heavy steel and welded or bolted to the core, these mounting feet provide superior strength in a compact design. Termination: combination slot/philips #6 screw, complete SEMS washer (suitable for 8 AWG to AWG solid or AWG stranded wire) Standard SEMS washers - supplied on all units up to and including 00VA Standard secondary fuse kits -utilizing / x / midget/type fuse clips (supplied all standard units up to and including 00VA) Optional primary fuse kits available utilizing / x / midget/type fuse clips (available on all standard units up to and including 00VA) Optional finger safe terminal covers available on all units up to and including 00VA UL Listed (approved for U.S. and anada) E Mark standard on all molded units up to and including 00VA (excluding PH***AJ & PH***AR) LIFETIME Warranty (Limited) RoHS ompliant special voltages and VA sizes available upon request excluding PH70PG, PH000PG, PH70MLI, PH000MLI Warranty Lifetime

7 SETION 9 HPS IMPERATOR TM Features & enefits ontinued Terminal connection numbers molded into the terminal block and correspond to the nameplate and wiring diagrams which makes connecting the HPS Imperator quick and simple. Standard secondary and optional primary fuse kits utilizing / x / midget/type fuse clips provide an economical solution to your fusing requirements (fuses not available). Innovative terminal block design (patent pending) provides for easy hook-up and installation of fuse clips. Optional removable finger safe terminal covers available on all units up to and including 00VA. ustom injection molded coil cover its unique fin shaped design combines superior cooling properties a clean, bold look. Made of heavy steel and welded or bolted to the core, these mounting feet provide superior strength in a compact design.

8 HPS IMPERATOR TM A D E A D E FIGURE A FIGURE A D E FIGURE Group A Primary Voltage: Secondary Voltage: 0 x 0 x 0 0 x 0 60 Hertz VA Rating atalog Number Mtg. Fig. Output Amps Overall Dimensions enters Slot A D E G X H Height Depth Approx. Ship Weight Lbs. Optional Primary Fuse Kit P/N 0 PH0AJ A 0./ x PFK 7 PH7AJ A 0.6/ x PFK 00 PH00AJ A 0.8/ x PFK 0 PH0AJ./ x PFK 0 PH0AJ.08/ x PFK 0 PH0AJ.9/ x PFK 00 PH00AJ.7/ x PFK 70 PH70AJ 6./ x PFK 000 PH000AJ 8./ x PFK 00 PH00AJ./ x PFK 000 PH000AJ 6.7/ / x. N/A N/A.7 N/A 000 PH000AJ.0/ / x. N/A N/A.9 N/A All dimensions in inches 000 PH000AJ.7/ / x.00 N/A N/A 97.9 N/A Secondary fuse clips, fuse clip mounting screws and primary and secondary voltage links/jumpers supplied standard transformers up to and including 00VA. Refer to page for wiring schematic drawing. Special voltage and VA sizes available upon request. Units over 00VA are UL approved and SA certified. All dimensions in inches 6

9 SETION 9 HPS IMPERATOR TM A D FIGURE A E A D E FIGURE Group Primary Voltage: Secondary Voltage: x. x x 60 Hertz VA Rating atalog Number Mtg. Fig. Output Amps Overall Dimensions enters Slot A D E G X H Height Depth Approx. Ship Weight Lbs. Optional Primary Fuse Kit P/N 0 PH0AR A.7/ x PFK 7 PH7AR A 6./ x PFK 00 PH00AR A 8./ x PFK 0 PH0AR./ x PFK 0 PH0AR 0.8/ x PFK 0 PH0AR 9./ x PFK 00 PH00AR.7/ x PFK Secondary fuse clips, fuse clip mounting screws and primary and secondary voltage links/jumpers supplied transformers up to and including 00VA. Refer to page for wiring schematic drawing. Special voltages and VA sizes available upon request. Units over 00VA are UL approved and SA certified. All dimensions in inches 7

10 HPS IMPERATOR TM A D E A D E FIGURE A FIGURE A D E FIGURE Group Primary Voltage: 0 x 80 0 x 60 0 x 0 Secondary Voltage: 0 x 0 x 0 0 x 0 0/60 Hertz VA Rating atalog Number Mtg. Fig. Output Amps Overall Dimensions enters Slot A D E G X H Height Depth Approx. Ship Weight Lbs. Optional Primary Fuse Kit P/N 0 PH0MQMJ A 0./ x PFK 7 PH7MQMJ A 0.6/ x PFK 00 PH00MQMJ A 0.8/ x PFK 0 PH0MQMJ./ x PFK 0 PH0MQMJ.08/ x PFK 0 PH0MQMJ.9/ x PFK 00 PH00MQMJ.7/ x PFK 70 PH70MQMJ 6./ x PFK 000 PH000MQMJ 8./ x PFK 00 PH00MQMJ./ x PFK 000 PH000MQMJ 6.7/ / x. N/A N/A. N/A 000 PH000MQMJ.0/ / x.00 N/A N/A 76.7 N/A 000 PH000MQMJ.7/ / x.00 N/A N/A. N/A Secondary fuse clips, fuse clip mounting screws and primary and secondary voltage links/jumpers supplied standard transformers up to All dimensions in inches and including 00VA. Refer to page for wiring schematic drawing. Special voltages and VA sizes available upon request. Units over 00VA are UL approved and SA certified, but do not carry the E mark. *** Available FATORY INSTALLED Primary and Secondary Fuse Kits up to 00VA. To order,add the suffix -FK to the abover part number. Refer to page 9 for details. *** 8

11 SETION 9 HPS IMPERATOR TM A D E A D E FIGURE A FIGURE Group D Primary Voltage: 0 x 80 0 x 60 0 x 0 Secondary Voltage: x. x x 0/60 Hertz VA Rating atalog Number Mtg. Fig. Output Amps Overall Dimensions enters Slot A D E G X H Height Depth Approx. Ship Weight Lbs. Optional Primary Fuse Kit P/N 0 PH0QR A.7/ x PFK 7 PH7QR A 6./ x PFK 00 PH00QR A 8./ x PFK 0 PH0QR./ x PFK 0 PH0QR 0.8/ x PFK 0 PH0QR 9./ x PFK 00 PH00QR.7/ x PFK Secondary fuse clips, fuse clip mounting screws and primary and secondary voltage links/jumpers supplied standard transformers up to and including 00VA. Refer to page for wiring schematic drawing. Special voltages and VA sizes available upon request. All dimensions in inches 9

12 HPS IMPERATOR TM A D E A D E FIGURE A FIGURE Group E Primary Voltage: 08 x 6 00 x x 80 Secondary Voltage: 0 x 0 x 0 0 x 0 0/60 Hertz VA Rating atalog Number Mtg. Fig. Output Amps Overall Dimensions enters Slot A D E G X H Height Depth Approx. Ship Weight Lbs. Optional Primary Fuse Kit P/N 0 PH0SP A 0./ x PFK 7 PH7SP A 0.6/ x PFK 00 PH00SP A 0.8/ x PFK 0 PH0SP./ x PFK 0 PH0SP.08/ x PFK 0 PH0SP.9/ x PFK 00 PH00SP.7/ x PFK 70 PH70SP 6./ x PFK 000 PH000SP 8./ x PFK Secondary fuse clips, fuse clip mounting screws and primary and secondary voltage links/jumpers supplied standard transformers up to and including 000VA. Refer to page 6 for wiring schematic drawing. Special voltages and VA sizes available upon request. All dimensions in inches 0

13 SETION 9 HPS IMPERATOR TM A D E FIGURE A A D E FIGURE A D E FIGURE Group F Primary Voltage: 0 x 0 x 0 0 x 0 Secondary Voltage: 0 x 0 x 0 0 x 0 0/60 Hertz VA Rating atalog Number Mtg. Fig. Output Amps Overall Dimensions enters Mtg. Slot A D E G X H Height Depth Approx. Ship Weight Lbs. Optional Primary Fuse Kit P/N 0 PH0PP A 0./ x PFK 7 PH7PP A 0.6/ x PFK 00 PH00PP A 0.8/ x PFK 0 PH0PP./ x PFK 0 PH0PP.08/ x PFK 0 PH0PP.9/ x PFK 00 PH00PP.7/ x PFK 70 PH70PP 6./ x PFK 000 PH000PP 8./ x PFK 00 PH00PP./ x PFK 000 PH000PP 6.7/ / x. N/A N/A. N/A Secondary fuse clips, fuse clip mounting screws and primary and secondary voltage links/jumpers supplied transformers up to All dimensions in inches and including 00VA. Refer to page 7 for wiring schematic drawing. Special voltages and VA sizes available upon request. Units over 00VA are UL approved and SA certified, but do not carry the E mark.

14 HPS IMPERATOR TM A D E A D E FIGURE A FIGURE Group G Primary Voltage: 0 x 0 x 0 0 x 0 Secondary Voltage: x. x x 0/60 Hertz VA Rating atalog Number Mtg. Fig. Output Amps Overall Dimensions enters Slot A D E G X H Height Depth Approx. Ship Weight Lbs. Optional Primary Fuse Kit P/N 0 PH0PG A.7/ x PFK 7 PH7PG A 6./ x PFK 00 PH00PG A 8./ x PFK 0 PH0PG./ x PFK 0 PH0PG 0.8/ x PFK 0 PH0PG 9./ x PFK 00 PH00PG.7/ x PFK 70 PH70PG 6./ x PFK 000 PH000PG 8./ x PFK Secondary fuse clips and fuse clip mounting screws supplied standard transformers up to and including 00VA. All dimensions in inches Primary and secondary voltage links/jumpers supplied standard transformers up to and including 000VA. Refer to page 8 for wiring schematic drawing. Special voltages and VA sizes available upon request. *** Available FATORY INSTALLED Primary and Secondary Fuse Kits up to 00VA. To order,add the suffix -FK to the abover part number. Refer to page 9 for details. ***

15 SETION 9 HPS IMPERATOR TM A D E FIGURE A A D E FIGURE Group H A D E FIGURE Primary Voltage: 600/80/0 7/60/0 0/0/0 Secondary Voltage: 0/00 /9 0/90 0/60 Hertz VA Rating atalog Number Mtg. Fig. Output Amps Overall Dimensions enters Slot A D E G X H Height Depth Approx. Ship Weight Lbs. Optional Primary Fuse Kit P/N 0 PH0MMH A x PFK 7 PH7MMH A x PFK 00 PH00MMH x PFK6 0 PH0MMH x PFK6 0 PH0MMH x PFK6 0 PH0MMH x PFK7 00 PH00MMH x PFK7 70 PH70MMH x PFK7 000 PH000MMH x PFK7 00 PH00MMH x PFK7 000 PH000MMH / x. N/A N/A.6 N/A 000 PH000MMH / x.00 N/A N/A 78.7 N/A Secondary fuse clips, fuse clip mounting screws and primary and secondary voltage links/jumpers supplied standard transformers up to and including 00VA. Refer to page 9 for wiring schematic drawing. Special voltage and VA sizes available upon request. Units over 00VA are UL approved and SA certified, but do not carry the E mark. All dimensions in inches

16 HPS IMPERATOR TM A D E A D E FIGURE A FIGURE Group I Primary Voltage: 80/0 60/0/08 0/0/00 Secondary Voltage: 0/ / 0/ 0/60 Hertz VA Rating atalog Number Mtg. Fig. Output Amps Overall Dimensions enters Slot A D E G X H Height Depth Approx. Ship Weight Lbs.s Optional Primary Fuse Kit P/N 0 PH0MLI A 0./ x PFK 7 PH7MLI A 0.6/ x PFK 00 PH00MLI A 0.87/ x PFK 0 PH0MLI.0/ x PFK6 0 PH0MLI.7/ x PFK6 0 PH0MLI.0/ x PFK7 00 PH00MLI./ x PFK7 70 PH70MLI 6./ x PFK7 000 PH000MLI 8.70/ x PFK7 Secondary fuse clips and fuse clip mounting screws supplied standard transformers up to and including 00VA. All dimensions in inches Primary and secondary voltage links/jumpers supplied standard transformers up to and including 000VA. Refer to page 60 for wiring schematic drawing. Special voltages and VA sizes available upon request. *** Available FATORY INSTALLED Primary and Secondary Fuse Kits up to 00VA. To order,add the suffix -FK to the abover part number. Refer to page 9 for details. ***

17 SETION 9 HPS IMPERATOR TM A D E A D E FIGURE A FIGURE Group J Primary Voltage: /00/80 Secondary Voltage: 0 x 0 0/60 Hertz VA Rating atalog Number Mtg. Fig. Output Amps Overall Dimensions enters Slot A D E G X H Height Depth Approx. Ship Weight Lbs. Optional Primary Fuse Kit P/N 0 PH0MEMX A 0./ x PFK 7 PH7MEMX A 0.68/ x PFK 00 PH00MEMX A 0.9/ x PFK 0 PH0MEMX.6/ x PFK6 0 PH0MEMX.7/ x PFK6 0 PH0MEMX.8/ x PFK7 00 PH00MEMX./ x PFK7 70 PH70MEMX 6.8/ x PFK7 000 PH000MEMX 9.09/ x PFK7 Secondary fuse clips, fuse clip mounting screws and primary and secondary voltage links/jumpers supplied transformers up to and including 000VA. Refer to page 6 for wiring schematic drawing. Special voltages and VA sizes available upon request. All dimensions in inches

18 HPS IMPERATOR TM A D E A D E FIGURE A FIGURE Group K Primary Voltage: 80/77/08 Secondary Voltage: 0 x 0 0/60 Hertz VA Rating atalog Number Mtg. Fig. Output Amps Overall Dimensions enters Slot A D E G X H Height Depth Approx. Ship Weight Lbs. Optional Primary Fuse Kit P/N 0 PH0MGJ A 0./ x PFK 7 PH7MGJ A 0.6/ x PFK 00 PH00MGJ A 0.8/ x PFK 0 PH0MGJ./ x PFK6 0 PH0MGJ.08/ x PFK6 0 PH0MGJ.9/ x PFK7 00 PH00MGJ.7/ x PFK7 70 PH70MGJ 6./ x PFK7 000 PH000MGJ 8./ x PFK7 Secondary fuse clips, fuse clip mounting screws and primary and secondary voltage links/jumpers supplied transformers up to All dimensions in inches and including 000VA. Refer to page 6 for wiring schematic drawings. Special voltages and VA sizes available upon request. 6

19 SETION 9 HPS IMPERATOR TM Recommendations For Overcurrent Protection UL and SA (North American) Standards North American standards, including UL 08, National Electric ode 0 and the anadian Electrical ode Part I, require overcurrent protection on all control circuit transformers. There are two options for overcurrent protection: Option Provide an overcurrent device in the primary circuit rated to the current of the transformer. The overcurrent limits are as follows: Primary 9 amps or more: Primary to 9 amps: Primary less than amps: no more than % of rated current. no more than 67% of rated current. no more than 00% of rated current for power circuits. no more than 00% of rated current for control circuits. This method is considered less desirable as start-up inrush to the transformer can frequently surpass the current rating of the device and result in nuisance interruptions. Option The second option is to install overcurrent devices in both the primary and secondary circuits of the transformer. In this option, the secondary device must be rated no more than % of rated current of the transformer and the primary no more than 0%. E permits 00% overcurrent on the primary for this option. In both options listed, it is recommended that time delay fuses be considered to avoid unnecessary interruptions. Secondary The overcurrent protection listed below, in amperes, is % of the rated current of the transformer. hoose the next higher fuse rating if these numbers do not correspond standard fuse selections. Sec. Voltage VA Rating

20 HPS IMPERATOR TM Recommendations for Overcurrent Protection continued... Primary (UL and SA) Pri. To assist in the selection of fuses, the following chart recommends the maximum primary fuse rating in amperes. The first number shown is the maximum overcurrent protection when the primary current is less than amps and the overcurrent protection device is rated for 00%. The second number shown (italic) is recommended when the primary is less than amps and the overcurrent device is to be rated at 00% of rated current. Where only one number is indicated, the primary is amps or more and one rating of over current protection is shown as optimal. hoose the next higher fuse rating if these numbers do not correspond standard fuse selections. VA Rating Volt References: UL 08,.7 UL 8,.6 and.7 NE 0-7 (c) exception # NE 0- (b) and E Part I, 6-6 Hammond Power Solutions Inc. 8 Data subject to change out notice.

21 SETION 9 HPS IMPERATOR TM Field Installed Fuse Kits Standard Secondary Fuse Kits (Field Installed) All HPS Imperator control transformers up to and including 00 VA are supplied standard secondary fuse kits which include: / x / midget/type fuse clips, fuse clip mounting screws, primary and secondary voltage links and the PHAK instruction sheet (note: secondary fuse clips and fuse clip mounting screws are not supplied on the PH70PG, PH000PG, PH70MLI, and PH000MLI). Optional Primary Fuse Kits (Field Installed) All HPS Imperator series machine tool industrial control transformers up to and including 00VA are available the following optional primary fuse kits: Kit Part Number PFK PFK PFK PFK PFK PFK PFK6 PFK6 PFK7 Applicable Transformer Part Number Suffix s Refer to Specification Tables on Pages 6 to 6 for Optional Primary Fuse Kit P/N Applicable VA Sizes Refer to Specification Tables on Pages 6 to 6 for Optional Primary Fuse Kit P/N Parts Included in Kit Note: Maximum allowable current rating on all primary and secondary fuse kits is 0 amps. fuse clips, mtg. screws, PHAK instruction sheet fuse clips, mtg. screws, PHAK instruction sheet fuse clips, mtg. screws, PHAK instruction sheet fuse clips, mtg. screws, jumper, finger guard, PHAK instruction sheet fuse clips, mtg. screws, jumper, finger guard, PHAK instruction sheet fuse clips, mtg. screws, jumper, finger guard, PHAK instruction sheet fuse clips, mtg. screws, jumper wire, PHAK instruction sheet fuse clips, mtg. screws, jumper wire, PHAK instruction sheet fuse clips, mtg. screws, jumper wire, PHAK instruction sheet Factory Installed Fuse Kits ** NEW ** Factory Installed Primary and Secondary Fuse Kits HPS now stocks some HPS Imperator series voltage groups FATORY INSTALLED primary and secondary fuse clips. To order, just add the suffix -FK to the end of the standard part number. Factory installed fusing only available on units up to 00VA. The voltage groups that are stocked are; Group (p/n: PH***MQMJ-FK) Group G (p/n: PH***PG-FK) Group I (p/n: PH***MLI-FK) Other voltage groups available factory installed fuse kits. Please contact your HPS sales or customer service representative for details. Note: All factory installed fuse kits are pre-wired at the transformers highest primary voltage and the lowest secondary voltage. To hook up at a different primary or secondary voltage, please refer to the wiring instruction sheet included the transformer. Sample Assembly Drawing for Voltage Link Installation (for 0VA to 00VA) Sample Assembly Drawing for Secondary Fuse lip Installation (for 0VA to 00VA) Note: HPS Imperator primary and secondary fuse kits are not suitable for branch circuit applications! Sample Assembly Drawing for Primary Fuse lip Installation (for 0VA to 00VA) 9

22 HPS IMPERATOR TM s The HPS Imperator series of machine tool industrial molded control transformers up to and including 00Va are available the following optional finger guard kits: Optional Unfused Kits Kit Part Number FG FG FG FG N/A Applicable Transformer Part Number Suffix s AJ, AR, MQMJ, MEMX, QR, SP, PG, PP MMH, MGJ, MLI All All (excluding PH00MMH) refer to FG, FG or FG below N/A Applicable VA Sizes to to 000 Note: Each finger guard kit supplies either the primary or secondary side. Parts Included in Kit finger guard (unfused), PHAK instruction sheet finger guard (unfused), PHAK instruction sheet finger guard (unfused), PHAK instruction sheet Optional Fused Kits Kit Part Number FGF FGF FGF FGF FG FG FG FG FG FG FG FG N/A Applicable Transformer Part Number Suffix s AJ, AR, MQMJ, MEMX, QR, SP, PG, PP MMH, MGJ, MLI All All (excluding PH00MMH) MMH All AJ, AR, MQMJ, MEMX, QR, SP, PG, PP MMH, MGJ, MLI All AJ, AR, MQMJ, QR, SP, PP MMH, MEMX, MGJ, MLI, PG All N/A Applicable VA Sizes , , to 000 Note: Each finger guard kit supplies either the primary or secondary side. Parts Included in Kit finger guard (fused), PHAK instruction sheet finger guard (fused), PHAK instruction sheet finger guard (fused), PHAK instruction sheet finger guard (fused), PHAK instruction sheet finger guard, PHAK instruction sheet finger guard, PHAK instruction sheet finger guard, PHAK instruction sheet finger guard, PHAK instruction sheet finger guard, PHAK instruction sheet finger guard, PHAK instruction sheet finger guard, PHAK instruction sheet finger guard, PHAK instruction sheet Sample Assembly Drawing for Installation (for 0, 7 and 00VA) Sample Assembly Drawing for Installation (for 0VA to 00VA) 0

23 SETION 9 HPS IMPERATOR TM Accessory Installation Guide Sample Accessory Drawings Voltage Link Fuse lips (for 0, 7 and 00VA) Fuse lips (for 0VA to 00VA) Sample Accessory Assembly Drawings Sample Assembly Drawings for Voltage Link Installation Fused & Unfused (for 0, 7 and 00VA) (for 0VA to 00VA) For units from 0VA to 00VA, the voltage links supplied can be installed between any two primary or secondary terminal bays. Please refer to PHWD or PHWD instruction sheet included your transformer for connection for details. Style A (left) Style (center) Style A (right) Sample Assembly Drawing for Installation (for 0, 7 and 00VA) Sample Assembly Drawing for Installation (for 0VA to 00VA) For units from 0VA to 0VA, the voltage links supplied must be installed between the primary or secondary terminal bays as indicated above Please refer to PHWD or PHWD instruction sheet included you transformer for connection details. Style A (left) Style (center) Style A (right) For units from 0VA to 00VA, the voltage links supplied must be installed between the primary or secondary terminal bays as indicated above Please refer to PHWD or PHWD instruction sheet included you transformer for connection details. Sample Assembly Drawing for Fuse lip Installation (for 0, 7 & 00VA) Sample Assembly Drawing for Primary Fuse lip Installation (for 0VA to 00VA) Note: HPS Imperator primary and secondary fuse kits are not suitable for branch circuit applications!

24 HPS IMPERATOR TM HPS Imperator Series - Wiring Schematic Drawings Group A 0V 7V 600V PH***AJ Schematic for 0, 7 and 00VA Units High Voltage () Install Supplied Jumpers/ Supply Lines Install Fuse (Primary Volts) Links etween Terminals onnect To lips To None, Unfused None 6, 7 -, V V 0V 0V 0V 0V Low Voltage () Install Supplied Links Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To 0 0 -, -, Unfused , Unfused 0 0 -, -, , 6-0V 7V 600V PH***AJ Schematic for 0VA to 00VA Units High Voltage () Install Supplied Jumpers/ Supply Lines Install Fuse (Primary Volts) Links etween Terminals onnect To lips To None, Unfused None, 6-7, V V 0V 6 0V 0V 0V Low Voltage () Install Supplied Links Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To 0 0 -, -, Unfused , Unfused 0 0 -, -, , -7

25 SETION 9 HPS IMPERATOR TM Group 0V 7V 600V PH***AR Schematic for 0, 7 and 00VA Units High Voltage () Install Supplied Jumpers/ Supply Lines Install Fuse (Primary Volts) Links etween Terminals onnect To lips To None, Unfused None 6, 7 -, -8 6 V V.V V V V Low Voltage () Install Supplied Links Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To. -, -, Unfused -, Unfused. -, -, 6 - -, 6-0V 7V 600V PH***AR Schematic for 0VA to 00VA Units High Voltage () Install Supplied Jumpers/ Supply Lines Install Fuse (Primary Volts) Links etween Terminals onnect To lips To None, Unfused None, 6-7, V V.V V V V Low Voltage () Install Supplied Links Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To. -, -, Unfused -, Unfused. -, -, -7 -, -7

26 HPS IMPERATOR TM HPS Imperator Series - Wiring Schematic Drawings continued Group 0V 0V 0V 6 7 0V 60V 80V 8 PH***MQMJ Schematic for 0, 7 and 00VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse (Primary Volts) etween Terminals onnect To lips To , -, Unfused , Unfused , - 6, 7 -, , 7 -, -8 0V V 0V 6 0V 0V 0V Low Voltage () Install Supplied Links Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To 0 0 -, -, Unfused , Unfused 0 0 -, -, , 6-0V 0V 0V 6 7 0V 60V 80V PH***MQMJ Schematic for 0VA to 00VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse (Primary Volts) etween Terminals onnect To lips To , -, Unfused , Unfused , -, 6-7, , 6-7, V V 0V 0V 0V 0V Low Voltage () Install Supplied Links Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To 0 0 -, -, Unfused , Unfused 0 0 -, -, , -7

27 SETION 9 HPS IMPERATOR TM Group D 0V 0V 0V 6 7 0V 60V 80V 8 PH***QR Schematic for 0, 7 and 00VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse (Primary Volts) etween Terminals onnect To lips To , -, Unfused , Unfused , - 6, 7 -, , 7 -, -8 6 V V.V V V V Low Voltage () Install Supplied Links Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To. -, -, Unfused -, Unfused. -, -, 6 - -, 6-0V 0V 0V 6 7 0V 60V 80V PH***QR Schematic for 0VA to 00VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse (Primary Volts) etween Terminals onnect To lips To , -, Unfused , Unfused , -, 6-7, , 6-7, V V.V V V V Low Voltage () Install Supplied Links Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To. -, -, Unfused -, Unfused. -, -, -7 -, -7

28 HPS IMPERATOR TM HPS Imperator Series - Wiring Schematic Drawings continued Group E 90V 00V 08V V 00V 6V 8 PH***SP Schematic for 0, 7 and 00VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse (Primary Volts) etween Terminals onnect To lips To , -, Unfused , Unfused , - 6, 7 -, , 7 -, -8 0V V 0V 6 0V 0V 0V Low Voltage () Install Supplied Links Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To 0 0 -, -, Unfused , Unfused 0 0 -, -, , 6-90V 00V 08V V 00V 6V PH***SP Schematic for 0VA to 000VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse (Primary Volts) etween Terminals onnect To lips To , -, Unfused , Unfused , -, 6-7, , 6-7, V V 0V 0V 0V 0V Low Voltage () Install Supplied Links Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To 0 0 -, -, Unfused , Unfused 0 0 -, -, , -7 6

29 SETION 9 HPS IMPERATOR TM Group F 0V V 0V 6 7 0V 0V 0V 8 PH***PP Schematic for 0, 7 and 00VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse (Primary Volts) etween Terminals onnect To lips To 0 0 -, -, Unfused , Unfused 0 0 -, - 6, 7 -, , 7 -, -8 0V V 0V 6 0V 0V 0V Low Voltage () Install Supplied Links Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To 0 0 -, -, Unfused , Unfused 0 0 -, -, , 6-0V V 0V 6 7 0V 0V 0V PH***PP Schematic for 0VA to 00VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse (Primary Volts) etween Terminals onnect To lips To 0 0 -, -, Unfused , Unfused 0 0 -, -, 6-7, , 6-7, V V 0V 0V 0V 0V Low Voltage () Install Supplied Links Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To 0 0 -, -, Unfused , Unfused 0 0 -, -, , -7 7

30 HPS IMPERATOR TM HPS Imperator Series - Wiring Schematic Drawings continued Group G 0V V 0V 6 7 0V 0V 0V 6 8 V V.V V V V 0V V 0V 6 7 0V 0V 0V PH***PG Schematic for 0, 7 and 00VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse (Primary Volts) etween Terminals onnect To lips To 0 0 -, -, Unfused , Unfused 0 0 -, - 6, 7 -, , 7 -, -8 Low Voltage () Install Supplied Links Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To. -, -, Unfused -, Unfused. -, -, 6 - -, 6 - PH***PG Schematic for 0VA to 00VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse (Primary Volts) etween Terminals onnect To lips To 0 0 -, -, Unfused , Unfused 0 0 -, -, 6-7, , 6-7, -8 6 V.V V 0V V 0V V V V 0V 0V 0V Low Voltage () Install Supplied Links Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To. -, -, Unfused -, Unfused. -, -, -7 -, -7 PH***PG Schematic for 70VA and 000VA Units High Voltage () Install Supplied Links Supply Lines Install Fuse (Primary Volts) etween Terminals onnect To lips To 0 0 -, -, Unfused , Unfused 0 0 -, -, 6-7, , 6-7, -8 Low Voltage () Install Supplied Links Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To V.V V V V V. -, -, Unfused -, Unfused Note: secondary fuse clips not available on PH70PG or PH000PG. 8

31 SETION 9 HPS IMPERATOR TM Group H 6 Dotted line represents supplied jumper lead. 600V/7V/0V 80V/60V/0V 0V/0V/0V 7 8 PH***MMH Schematic for 0 and 7VA Units High Voltage () Install Supplied Jumpers Supply Lines Install Fuse (Primary Volts) etween Terminals onnect To lips To None, Unfused None, 7 Unfused None, Unfused , -, , -, , -, -8 00V/9V/90V Low Voltage () Install Supplied Jumpers/ Load Lines Install Fuse (Secondary Volts) Links etween Terminals onnect To lips To 0V/V/0V None, Unfused None, Unfused 0 0 None, None, 6 - PH***MMH Schematic for 00VA to 00VA Units 7 Dotted line represents supplied jumper lead. 600V/7V/0V 80V/60V/0V 0V/0V/0V 8 6 High Voltage () Install Supplied Jumpers Supply Lines Install Fuse (Primary Volts) etween Terminals onnect To lips To None, 6 Unfused None, Unfused None, Unfused , -7, , -7, , -7, -8 00V/9V/90V 0V/V/0V 7 Low Voltage () Install Supplied Jumpers/ Load Lines Install Fuse (Secondary Volts) Links etween Terminals onnect To lips To 0 0 None, Unfused None, Unfused 0 0 None, None, -7 9

32 HPS IMPERATOR TM HPS Imperator Series - Wiring Schematic Drawings continued Group I 6 Dotted line represents supplied jumper lead. 80V/60V/0V 0V/0V/0V 08V/00V 0V/V/0V 6 7 V/V/V 8 PH***MLI Schematic for 0, 7 and 00VA Units High Voltage () Install Supplied Jumpers Supply Lines Install Fuse (Primary Volts) etween Terminals onnect To lips To None, Unfused None, 7 Unfused None, Unfused , -, , -, , -, -8 Low Voltage () Install Supplied Jumpers Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To 0 0 None, Unfused None, Unfused 0 0 None, 6 - None, 6-7 Dotted line represents supplied jumper lead. 80V/60V/0V 0V/0V/0V 08V/00V 8 6 PH***MLI Schematic for 0VA to 00VA Units High Voltage () Install Supplied Jumpers Supply Lines Install Fuse (Primary Volts) etween Terminals onnect To lips To None, 6 Unfused None, Unfused None, Unfused , -7, , -7, , -7, -8 V/V/V 0V/V/0V 7 Low Voltage () Install Supplied Jumpers Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To 0 0 None, Unfused None, Unfused 0 0 None, -7 None, -7 7 Dotted line represents supplied jumper lead. 80V/60V/0V 0V/0V/0V 08V/00V 8 6 PH***MLI Schematic for 70VA and 000VA Units High Voltage () Install Supplied Jumpers Supply Lines Install Fuse (Primary Volts) etween Terminals onnect To lips To None, 6 Unfused None, Unfused None, Unfused , -7, , -7, , -7, -8 V/V/V 0V/V/0V Low Voltage () Install Supplied Jumpers Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To 0 0 None, Unfused None, Unfused Note: secondary fuse clips for V tap not available on the PH70MLI or PH000MLI units. 60

33 SETION 9 HPS IMPERATOR TM Group J PH***MEMX Schematic for 0, 7 and 00VA Units 6 80V 00V Dotted line represents supplied jumper lead. V 7 8 High Voltage () Install Supplied Jumpers Supply Lines Install Fuse (Primary Volts) etween Terminals onnect To lips To None, Unfused 00 None, 7 Unfused 80 None, Unfused -8 6, -, , -, , -, -8 6 Low Voltage () Install Supplied Links Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To 0V 0V 0 -, -, Unfused 0 -, Unfused 0 -, -, 6-0 -, 6 - PH***MEMX Schematic for 0VA to 000VA Units 7 80V Dotted line represents supplied jumper lead. 00V V 8 6 High Voltage () Install Supplied Jumpers Supply Lines Install Fuse (Primary Volts) etween Terminals onnect To lips To None, 6 Unfused 00 None, Unfused 80 None, Unfused 8-6, -7, , -7, , -7, V 0V Low Voltage () Install Supplied Links Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To 0 -, -, Unfused 0 -, Unfused 0 -, -, , -7 6

34 HPS IMPERATOR TM HPS Imperator Series - Wiring Schematic Drawings continued Group K PH***MGJ Schematic for 0, 7 and 00VA Units 6 08V Dotted line represents supplied jumper lead. 77V 80V 7 8 High Voltage () Install Supplied Jumpers Supply Lines Install Fuse (Primary Volts) etween Terminals onnect To lips To 80 None, Unfused 77 None, 7 Unfused 08 None, Unfused , -, , -, , -, -8 6 Low Voltage () Install Supplied Links Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To 0V 0V 0 -, -, Unfused 0 -, Unfused 0 -, -, 6-0 -, 6 - PH***MGJ Schematic for 0VA to 000VA Units 7 08V Dotted line represents supplied jumper lead. 77V 80V 8 6 High Voltage () Install Supplied Jumpers Supply Lines Install Fuse (Primary Volts) etween Terminals onnect To lips To 80 None, 6 Unfused 77 None, Unfused 08 None, Unfused , -7, , -7, , -7, V 0V Low Voltage () Install Supplied Links Load Lines Install Fuse (Secondary Volts) etween Terminals onnect To lips To 0 -, -, Unfused 0 -, Unfused 0 -, -, , -7 6

35 SETION 9 Q SERIES ONTROL TRANSFORMERS SINGLE PHASE ENLOSED ONTROL TRANSFORMER FEATURES For applications where a cost effective approach to general purpose loads indoor or outdoor is required, consider the Q series, single phase encapsulated control transformer. These units are specifically designed for the following applications; General purpose enclosed control applications used to adjust a supply voltage to match a load requirement. Supplying machine tool circuits. Actuating relays, bells, signal and alarm systems. Operating small motors, valves and dampers. Industrial lighting and circuit isolation. 0 to 000VA SINGLE PHASE ENLOSED ONTROL STANDARD SPEIFIATIONS 0 to 000VA ENEFITS UL Listed SA ertified Frequency File: E09 File: LR90 60 Hertz Insulation System Up to kva; lass, 80 temperature rise. Assures long life and reliable performance. to kva; lass F, temperature rise. Standard Design Single Phase, all welded core construction Rugged one-piece assembly low noise made high quality, high permeability silicon provides optimum performance and reliability. steel laminations. omputer designed coils, accurately wound Provides enhanced voltage regulation and optimum mean turns made from high excellent thermal characteristics and quality magnetic wire insulation film. compliments modern winding techniques. Encapsulation All units from 0VA to kva are encapsulated ompletely encloses the core and coil to seal electrical grade silica sand and resin compounds. out moisture, airborne contaminants and eliminates corrosion & insulation deterioration. Enclosure Type Heavy Duty Encapsulated NEMA Type R Meets the heavy industrial trade requirements (conduit knockouts on sides and rear) for indoor/outdoor enclosed transformers. Termination Front accessible wiring compartment high Ample space for transformer connections. and low voltage copper lead wires or tabs. For primary and secondary terminations. Designed for vertical or horizontal mounting. Facilitates any installation requirement. 6

36 Q SERIES ONTROL TRANSFORMERS SINGLE PHASE, NEMA R STYLE ENLOSURE 0/80 Primary Volts 0/0 Secondary Volts 60 Hz atalog ase Approx. Dimensions Approx. Mtg Type Wiring VA Number Style (Inches) Weight Diagram (Page 8) Width Depth Height (Lbs.) W - Wall (Pages 8-67) 0 QEE6P NQ W SD 00 QEG6P NQ W SD 0 QEH6P NQ W SD 00 QEI6P NQ W SD 0 QEJ6P NQ W SD 0 QEK6P NQ W SD 00 QEL6P NQ W SD 70 QEM6P NQ W SD 000 QEN6P NQ W SD 00 QEP6P NQ W SD 000 QEQ6P NQ W SD 000 QES6P NQ W SD 000 QEU6P NQ W SD 600 Primary Volts 0/0 Secondary Volts 60 Hz atalog ase Approx. Dimensions Approx. Mtg Type Wiring VA Number Style (Inches) Weight Diagram (Page 8) Width Depth Height (Lbs.) W - Wall (Pages 8-67) 0 QEE9P NQ W SD 00 QEG9P NQ W SD 0 QEH9P NQ W SD 00 QEI9P NQ W SD 0 QEJ9P NQ W SD 0 QEK9P NQ W SD 00 QEL9P NQ W SD 70 QEM9P NQ W SD 000 QEN9P NQ W SD 00 QEP9P NQ W SD 000 QEQ9P NQ W SD 000 QES9P NQ W SD 000 QEU9P NQ W SD 600 Primary Volts / Secondary Volts 60 Hz atalog ase Approx. Dimensions Approx. Mtg Type Wiring VA Number Style (Inches) Weight Diagram (Page 8) Width Depth Height (Lbs.) W - Wall (Pages 8-67) 0 Q0PR NQ W SD 00 Q0PR NQ W SD 0 QPR NQ W SD 00 Q0PR NQ W SD 0 QPR NQ W SD 0 QPR NQ W SD 00 Q0PR NQ W SD 70 Q7PR NQ W SD 000 Q0PR NQ W SD 00 QPRF NQ W SD 000 Q00PRF NQ W SD 000 Q00PRF NQ W SD 000 Q00PRF NQ W SD 6

37 SETION 9 MV SERIES MEDIUM VOLTAGE INDUSTRIAL ONTROL TRANSFORMERS MV Series Medium Voltage ontrol Transformers Applications For applications where a cost effective medium voltage control transformer is required, consider the MV series, single phase medium voltage industrial control transformer. These units are specifically designed for general purpose industrial control applications used to adjust a medium voltage supply to match a low voltage load requirement. Standard Features Available from 00 volts to 700 volts 60 Hz. design 80 insulation, temperature rise Superior quality silicon steel core Standard leads (optional terminal board available) Available in six (6) standard voltage combinations Meets UL, SA and NEMA standards MV Medium Voltage ontrol Transformer MV Series Selection Table Primary Secondary PART NUMERS Wiring Voltage Voltage Diagram 00 VA 70 VA 000 VA 000 VA 000 VA 000 VA (Pages 8-67) 00 0/0 MV00RE MV70RE MV000RE MV000RE MV000RE MV000RE SD 00 0/0 MV00QE MV70QE MV000QE MV000QE MV000QE MV000QE SD 60 0/0 MV00SE MV70SE MV000SE MV000SE MV000SE MV000SE SD 800 0/0 MV00TE MV70TE MV000TE MV000TE MV000TE MV000TE SD /0 MV00UE MV70UE MV000UE MV000UE MV000UE MV000UE SD 700 0/0 MV00VE MV70VE MV000VE MV000VE MV000VE MV000VE SD MV Series Dimensional Specification Table (00V to 800V Primary) VA Fig. MV Dimensions Weight Size No. A D E Slot F X G (Lbs.) 00 VA X VA X VA X VA X VA X VA X Note : Height dimension will increase by. inches optional MVFK fuse kit installed. All Dimensions In Inches Note : Please contact sales for dimensional specifications on 6600V and 700V primary units. 6

HPS Imperator Encapsulated Industrial Control Transformer

HPS Imperator Encapsulated Industrial Control Transformer HPS Imperator Innovative Design The Perfect Solution Features and enefits The HPS Imperator series is a unique innovative and compact design that provides the ideal solution for any industrial control

More information

HPS Imperator. Innovative Solutions. Progressive. Encapsulated Machine Tool Industrial Control Transformers

HPS Imperator. Innovative Solutions. Progressive. Encapsulated Machine Tool Industrial Control Transformers Progressive Innovative Solutions HPS Imperator Encapsulated Machine Tool Industrial Control Transformers Lifetime Warranty Unique Terminal Block Innovative Fusing Method Patented Design HPS Imperator Control

More information

INDUSTRIAL CONTROL AND GENERAL PURPOSE ENCLOSED TRANSFORMERS

INDUSTRIAL CONTROL AND GENERAL PURPOSE ENCLOSED TRANSFORMERS INDUSTRIAL ONTROL AND GENERAL PURPOSE ENLOSED TRANSFORMERS HPS Imperator, HPS Spartan, HPS Fusion and Q Series Transformers ontrol Transformer Quick Selection harts... 8 What Is A ontrol Transformer?...

More information

HPS Imperator. Innovative Solutions. Progressive. Encapsulated Machine Tool Industrial Control Transformers

HPS Imperator. Innovative Solutions. Progressive. Encapsulated Machine Tool Industrial Control Transformers Progressive Innovative Solutions HPS Imperator Encapsulated Machine Tool Industrial Control Transformers Lifetime Warranty Unique Terminal Block Innovative Fusing Method Patented Design HPS Imperator Control

More information

PH250MQMJ CNTL 250VA 240X X240

PH250MQMJ CNTL 250VA 240X X240 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 PH250MQMJ CNTL 250VA 240X480-120X240 Hammond Power Solutions Catalog Number Manufacturer Description Weight per unit Product

More information

Machine Tool Industrial Control Transformers

Machine Tool Industrial Control Transformers Hammond Power Solutions Inc. Page of Machine Tool Industrial ontrol Transformers The HPS Imperator TM series of machine tool rated industrial control transformers are specifcally designed to meet high

More information

HPS Imperator Series Control Transformers meet or exceed the standards established

HPS Imperator Series Control Transformers meet or exceed the standards established HPS IMPRATOR HPS Imperator Machine Tool Industrial ontrol Transformer The Perfect Solution The HPS Imperator line of machine tool industrial control transformers are specifically designed to meet the high

More information

HPS Imperator Machine Tool Industrial Control Transformer

HPS Imperator Machine Tool Industrial Control Transformer HPS Imperator Machine Tool Industrial ontrol Transformer The Perfect Solution The HPS Imperator line of machine tool industrial control transformers are specifically designed to meet the high inrush industrial

More information

Machine Tool Industrial Control Transformers

Machine Tool Industrial Control Transformers Hammond Power Solutions Inc. Page of Machine Tool Industrial Control Transformers The HPS Imperator TM series of machine tool rated industrial control transformers are specifcally designed to meet high

More information

CPT Series Control Transformers

CPT Series Control Transformers CPT Series Control s 50 VA to 500 VA 480 VAC Primary 120 VAC Secondary (Inrush VA data should be obtained from the device manufacturers.) The inrush load power factor is difficult to determine without

More information

INDUSTRIAL CONTROL TRANSFORMERS

INDUSTRIAL CONTROL TRANSFORMERS INDUSTRIAL ONTROL TRANSORMRS PT, PH, PTD, PHD, SL, Q, M, VM, MV Series ontrol Transformers ontrol Transformer Quick Selection harts... 30 What Is A ontrol Transformer?... 31 ontrol Transformer Selection

More information

HPS Fusion General Purpose Enclosed Transformer

HPS Fusion General Purpose Enclosed Transformer HPS Fusion General Purpose Enclosed Transformer Our Company Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the short wave radio

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

HPS Spartan Industrial Open Core & Coil Control Transformer

HPS Spartan Industrial Open Core & Coil Control Transformer HPS Spartan Industrial Open Core & Coil Control Transformer Our Company Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the

More information

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers

More information

TA Ta VA CTRL-XFRMR

TA Ta VA CTRL-XFRMR 3804 South Street 7964-7263, TX Nacogdoches Phone: 936-69-7941 Fax: 936-60-468 TA2437 Ta-2-437 10VA CTRL-XFRMR Acme Electric Catalog Number TA2437 Manufacturer Acme Electric Description Control Transformer,

More information

HPS Fusion General Purpose Enclosed Transformer

HPS Fusion General Purpose Enclosed Transformer HPS Fusion General Purpose Enclosed Transformer Our Company Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the short wave radio

More information

HPS Spartan. Industrial Open Core & Coil Control Transformer

HPS Spartan. Industrial Open Core & Coil Control Transformer HPS Spartan Industrial Open Core & Coil Control Transformer OUR COMPANY Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the

More information

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers Type FEC Epoxy Encapsulated, Copper-Wound Transformers ISO 900:2008 REGISTERED 0 Transformer Selector Guide Type FEC Transformers...Page 02 Primary Fusing Option...Page 07 Primary Overcurrent Selection...Page

More information

Industrial Control Power Transformers Class MT

Industrial Control Power Transformers Class MT Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments

More information

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS Hammond Power Solutions Inc. Page 1 of 1 ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS HPS Titan has been designed to operate in harsh environments/hazardous locations where dangerous gases, liquids,

More information

Industrial Control Power Transformers

Industrial Control Power Transformers 09/10/15 Class MT Features b Enclosed coils (50-5000); Completely encloses the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial

More information

General Purpose Buck - Boost Wiring Diagrams... 86

General Purpose Buck - Boost Wiring Diagrams... 86 SECTION LOW VOLTAGE/ LIGHTING TRANSFORMERS General Purpose... 84 Buck - Boost... 85 Wiring Diagrams... 8 LOW VOLTAGE LIGHTING TRANSFORMERS & POWER SUPPLIES Low Voltage Lighting A greater selection for

More information

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits. Class I Division 2 10 1 to 25 kva Applications n Class I Division 2 units are used in hazardous locations to maintain a safe environment. Specifications n Class I Division 2, Groups A, B, C, D n T3C temperature

More information

Bulletin 1497A Machine Tool Transformers

Bulletin 1497A Machine Tool Transformers Bulletin A Overview/Catalog Number Explanation Bulletin A Bulletin A are designed to reduce supply voltages to control circuits. The complete line of transformers is available with optional factory-installed

More information

Bulletin 1497A Machine Tool Transformers

Bulletin 1497A Machine Tool Transformers Bulletin A Overview/Catalog Number Explanation Bulletin A Bulletin A are designed to reduce supply voltages to control circuits. The complete line of transformers is available with optional factory-installed

More information

9070T150D1 Industrial Control Transformer, 150VA

9070T150D1 Industrial Control Transformer, 150VA Product Data Sheet 9070T150D1 Industrial ontrol Transformer, 150 Technical haracteristics Application Approvals atalog Reference Number Depth Height Width Winding Material Temperature Rise Type Primary

More information

SECTION 3 HPS CENTURION R REACTORS AND RC DV/DT FILTERS

SECTION 3 HPS CENTURION R REACTORS AND RC DV/DT FILTERS HPS CENTURION R REACTORS AND RC DV/DT FILTERS Single and Three Phase Why Choose a Line Reactor?... 98 Construction Features... 100 HPS Centurion R Reactors Specifications... 101 Part Number Guide... 102

More information

Contactors & Starters Index

Contactors & Starters Index ontactors & Starters Index NEMA ontrol Description Page Number General Information - HP... A Magnetic ontactors - HP...4 A Magnetic Reversing ontactors - HP... 4 A Magnetic Starters - HP... A Magnetic

More information

Control Circuit Transformers

Control Circuit Transformers Technical Data Control Circuit Transformers Bulletin Numbers 1497, 1497A, 1497B, 1497D Topic Page Summary of Changes 1 Control Circuit Transformers Product Overview 2 Bulletin 1497 Global Control Circuit

More information

Unit Substation Transformers 5 and 15 KV Class

Unit Substation Transformers 5 and 15 KV Class Transformers 5 and 15 KV Class 85 General Information Description Federal Pacific unit substation transformers are available in a wide variety of types and ratings to provide reliable and versatile electrical

More information

Features, Benefits and Functions

Features, Benefits and Functions -8 Buck-Boost and Lighting Single- and Three-Phase February 007 Single- and Three-Phase Applications, 60 Hz Type EP Product Description Types EP, EPT Sand and Resin Encapsulated design. Suitable for indoor

More information

Planning Low Voltage Layouts

Planning Low Voltage Layouts Outdoor_ransformers_Outdoor_ransformers.qxd 11-11-10 3:40 PM Page 1 1850 Wilson Avenue, oronto, Ontario, anada, M9M 1A1 Ph: 416-741-7336 Fax: 416-741-9104 SEION H OUDOOR H1 OUDOOR Low Voltage ransformers

More information

AC Line / Load Reactors

AC Line / Load Reactors AC Line / Load Reactors Table of Contents Delivery / Lead Time.PB03-1100 -2 Selection & Pricing PB03-1100 -4 Replacement Parts..PB03-1100-8 Product Modifications / Options..PB03-1100 -9 Product Specifications..PB03-1100

More information

HPS Fortress. Commercial Encapsulated Distribution Transformers

HPS Fortress. Commercial Encapsulated Distribution Transformers HPS Fortress Commercial Encapsulated Distribution Transformers OUR COMPANY Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the

More information

Bulletin A 1497B 1497D Type Control Circuit Transformer Machine Tool Transformer Control Power Transformer General Purpose Transformer

Bulletin A 1497B 1497D Type Control Circuit Transformer Machine Tool Transformer Control Power Transformer General Purpose Transformer Bulletin, A, B, D Transformers Product Overview Transformers Bulletin A B D Type Control Circuit Transformer Machine Tool Transformer Control Power Transformer General Purpose Transformer Features Single,

More information

D I D /240 I. D x /240 I D / x x /24 I. D x /120

D I D /240 I. D x /240 I D / x x /24 I. D x /120 ndustrial ontrol Transformers lass 9070 www.square.com or the most up-to-date information The T units are designed for the global market and are the best choice when size and cost are of concern. This

More information

Inexpensive as. Applications

Inexpensive as. Applications Our Company Hammond Power Solutions (HPS) was established in in Guelph, Ontario and has grown from a small family owned business in the short wave radio market, to the industry leader in magnetic transformer

More information

Industrial Control Transformers

Industrial Control Transformers Industrial Control Types MTE and MTK.1 Standards and Certifications................................. Catalog Selection.................................. Type MTE...............................................

More information

Low Voltage Lighting Power Supplies

Low Voltage Lighting Power Supplies SECTION VI LO VOLTAGE LIGTING TRANSFORMERS & POER SUPPLIES Low Voltage Lighting Power Supplies A greater selection for your indoor and outdoor low voltage lighting projects hy Low Voltage? Acme s Low Voltage

More information

HPS TITAN HPS TITAN. Three Phase. Single Phase

HPS TITAN HPS TITAN. Three Phase. Single Phase The HPS Titan line of transformers have been designed for installation in harsh environments where efficiency and performance are key. Typical applications include institutional, commercial, industrial,

More information

Industrial Control Transformers

Industrial Control Transformers The SBE - Encapsulated, Copper Wound Series The SolaHD SBE Encapsulated industrial control transformers are epoxy encapsulated to seal the transformer windings against moisture, dirt and industrial contaminants.

More information

Engineered solutions for power and the environment

Engineered solutions for power and the environment C e n t u ry S e r i e s I n d u s t r i a l C o n t r o l T r a n s f o r m e r s Engineered solutions for power and the environment s we celebrate our 100th nniversary, the Dongan Team wishes to thank

More information

HPS Fortress. Encapsulated Transformers for Commercial Applications

HPS Fortress. Encapsulated Transformers for Commercial Applications HPS Fortress Encapsulated Transformers for Commercial Applications HPS Fortress Encapsulated Transformers for Commercial Applications HPS Fortress is an innovative design that provides the ideal solution

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

Single-Phase Ventilated

Single-Phase Ventilated Single-Phase Ventilated 1 15 to 1,650 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency

More information

Control Transformers

Control Transformers J., APRJL, 1983 SUP RSEPES1/8111TION Control Transformers FILE: Control Products Catalog Machine Tool Transformer Disconnects CONTENTS Description Class Pages General............ 97... 23 Application Data.........

More information

Totally Enclosed Non-Ventilated

Totally Enclosed Non-Ventilated 5 15 to 500 kva 5 Applications n Designed for commercial and industrial loads in challenging environments Specifications n NEMA3R rated enclosure n Single Phase units 15 through 100 kva n Three Phase units

More information

Distribution Dry Type Transformers 600 Volts Class Single and Three Phase Selection

Distribution Dry Type Transformers 600 Volts Class Single and Three Phase Selection 7 Distribution Dry Type Transformers 600 Volts Class Single and Three Phase 600 Volts Class Single Phase 0.25 167 KVA Three Phase 3 1000 KVA Features Standard units are UL listed and are designed in accordance

More information

MTE AC Line / Load Reactors Price book

MTE AC Line / Load Reactors Price book Table of Contents TABLE OF CONTENTS...1 STANDARD DELIVERY SCHEDULE...2 REACTOR SELECTION & PRICING...4 208-240 VOLT (3-PHASE)...4 400 VOLT (50 HZ) USE FOR 380-415 VOLTS...5 480 VOLT (3-PHASE) REACTOR...6

More information

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description .1 NM ontactors and Starters Non- and ontactors ontactors Non- and Product escription Non- ontactors are most commonly used to switch motor loads in applications where running overcurrent protection is

More information

Three Phase Transformers

Three Phase Transformers Three Phase Transformers ontents Three Phase - General Purpose... 26 Three Phase - General Purpose Scott ed... 30 Three Phase - dditional ombinations vailable... 31 Three Phase - ion Diagrams... 32 Series

More information

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q 14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose

More information

Transformers 6. Gross Automation (877)

Transformers 6. Gross Automation (877) Transformers 6 Hevi-Duty Family of Transformers Sola/Hevi-Duty offers a broad range of transformers to meet many applications. These dry-type transformers are offered encapsulated, ventilated or non-ventilated,

More information

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers QO and Miniature ircuit reakers Miniature ircuit reakers lass 720 / Refer to atalog 0730T9801 Low mpere Miniature ircuit reakers unit mount miniature circuit breakers (cable-in/cable-out) are ideal for

More information

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS Originated 1/85 Revised 6/95 Revised 6/02 Revised 11/05 Revised 4/08 Revised 11/09 Revised 1/12 Revised 11/12 Revised

More information

Mfg. Part No.* VA ACCESSORIES

Mfg. Part No.* VA ACCESSORIES Find Datasheets Online CONTROL HPS IMPERATOR MACHINE TOOL INDUSTRIAL CONTROL Up to 100VA 00V class 50/0 Hz Superior insulation system Constructed with high quality silicon steel laminations PRIMARY: 240/480,

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5 PAGE 1 OF 5 USE: Requirements for entrance equipment. PREVIOUS REVISION 07-01-98 ORIGINATED 03-94 PREVIOUS NUMBER ER 100 (12-01-81) LATEST REVISION: Updated meter socket labeling specification and instrument

More information

steel standard SST DUCK components Epoxy Resin Rated Insulation System recognized stainless steel output shaft seal

steel standard SST DUCK components Epoxy Resin Rated Insulation System recognized stainless steel output shaft seal Premium Efficiency Washguard Motors - Now Available! WASHGUARD MOTORS WASHGUARD MOTORS AVAILABLE IN FIVE STYLES Maximum service in critically clean or corrosive environments PREMIUM WASHGUARD ALL-STAINLESS

More information

Dry Type Distribution Transformers

Dry Type Distribution Transformers Selection Steps A. Use the following steps below to manually select a transformer. B. Find the electrical load requirements. These are: 1. Load operating voltage. 2. Load frequency (expressed in Hz). 3.

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................

More information

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV. DIN HV Distribution DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from 2.3-38kV. Their compact dimensions and non-venting characteristics make them

More information

Transformer Installation, Operation, and Maintenance Manual

Transformer Installation, Operation, and Maintenance Manual Transformer Installation, Operation, and Maintenance Manual CONTENTS INTRODUCTION......................................... 2 INSPECTION UPON RECEIVING... 2 STORAGE...............................................

More information

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators MAx-305 & MAx-38 Series MAx-405 Through MAx-49 Series Two-Position Actuators General Instructions Application For two-position operation of dampers, valves, and other equipment which require the return

More information

112.5 kva Transformer Delta Primary - 240/120V Secondary - 60 Hz - 3 Phase - NEMA 3R

112.5 kva Transformer Delta Primary - 240/120V Secondary - 60 Hz - 3 Phase - NEMA 3R 112.5 kva Transformer 480 Delta Primary 240/120V Secondary 60 Hz 3 Phase NEMA 3R Part #: MT112.5KVA480240.1203P Page: 1 The MT112.5KVA480240.1203P 480D 3 Phase Energy Efficient isolation transformer from

More information

Application Engineering

Application Engineering Application Engineering March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the

More information

Power Generation for the 21st Century

Power Generation for the 21st Century Power Generation for the 21st Century Generator Ratings: kw 118 to 2370 (60 Hertz) kva 136 to 2400 (50 Hertz) ISO 9002 Certified A Subsidiary of Regal-Beloit Corporation innovation, Since its market introduction,

More information

2000 Cooper Bussmann, Inc. Page 1 of 9 10/04/00

2000 Cooper Bussmann, Inc. Page 1 of 9 10/04/00 DO YOU KNOW THE FACTS ABOUT SINGLE-POLE INTERRUPTING RATINGS? YOU MAY BE IN TROUBLE! Typical plant electrical systems use three-phase distribution schemes. As an industry practice, short-circuit calculations

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

Three-Phase Ventilated

Three-Phase Ventilated Three-Phase Ventilated 2 15 to 2,500 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Circuit Breakers. Switching & Controls.  Selection Guide NC1V Series Dimensions... Switching & ontrols Selection Guide... 1028 1V Series... 1029 Dimensions... 1035 www.ide.com/circuitbreaker ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Industrial Control Transformers

Industrial Control Transformers Industrial Control Transformers 5 The SBE - Encapsulated Series The SBE Encapsulated industrial control transformers are epoxy encapsulated to seal the transformer windings against moisture, dirt and industrial

More information

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures Applications The PlexPower panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Wastewater

More information

Jefferson Electric Class I Division 2 Transformers for hazardous locations

Jefferson Electric Class I Division 2 Transformers for hazardous locations Class I Division 2 Jefferson Electric Class I Division 2 Transformers for hazardous locations Jefferson Electric offers a full line of Class I Division 2 transformers. Jefferson Electrics Class I Division

More information

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B) 4 Engineering Information Principles of Operation A solenoid valve is a combination of two basic functional units: A solenoid (electromagnet) with its core A valve body containing one or more orifices

More information

Midwest Dry Type Transformers

Midwest Dry Type Transformers Midwest Electric Products Midwest Dry Type Transformers Reliable and Efficient Performance From a Name You Know DOE 2016 Efficiency Transformers Catalog General Information...2 General Purpose... 3 Single-Phase

More information

30 KVA Transformer - 480V 3 Phase to 208Y/120V - NEMA 3R Enclosure - Copper Windings

30 KVA Transformer - 480V 3 Phase to 208Y/120V - NEMA 3R Enclosure - Copper Windings 30 KVA Transformer 480V 3 Phase to 208Y/120V NEMA 3R Enclosure Copper Windings Part #: MT30KVA3P480V208.120CU Page: 1 MT30KVA3P480V208.120CU 30kVA Transformer 480V 3 Phase480V Delta Primary Voltage 208Y/120V

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents. PART 1: GENERAL 1.01 This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is to apply the

More information

ALL PURPOSE CNC/HEAVY DUTY

ALL PURPOSE CNC/HEAVY DUTY ALL PURPOSE CNC/HEAVY DUTY Rotary Phase Converters 240 & 480 VOLT SERIES Rotary Phase Con verter Operation & Installation Manual MTPC-RB-208.240-1P-10HP-3P DANGER: HIGH VOLTAGE Electric shock could result

More information

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING SineWave Guardian TM 380V 600V INSTALLATION GUIDE FORM: SWG-IG-E REL. October 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of

More information

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories QO and Miniature ircuit reakers QO ircuit reaker ccessories lass 1130 / Refer to atalog 0730T9801 IRUIT RKRS ccessories for Use with QO and QO Miniature ircuit reakers Handle ttachments escription at.

More information

Non-Ventilated Automation Transformers 6

Non-Ventilated Automation Transformers 6 Non-Ventilated Automation Transformers 6 Automation Transformers - Non-Ventilated 50 VA to 45 SolaHD encapsulated transformers are rated for Hazardous Locations (Class 1, Division 2, Group A-D) as well

More information

HIGH INTENSITY DISCHARGE BALLASTS

HIGH INTENSITY DISCHARGE BALLASTS Philips Advance ballasts are available to operate the wide variety of metal halide, high pressure sodium and low pressure sodium lamps available in today s marketplace. Like fluorescent, lamps are gas

More information

Mica Element Support. Compacted Quartz Sand. Length B

Mica Element Support. Compacted Quartz Sand. Length B Construction A Tin-Plated Brass Caps Dimensional Information for Trans-Guard s NOMINAL 5.5 Resin-Rich Filament Wound Glass/Epoxy Body 3 75 80 200 3 50 5 80 5 125 3 50 5 5 100 23.0 50 Low Current Interruption

More information

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation M T E C o r p o r a t i o n MTE Series RL Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL. 060227 2006 MTE Corporation Important User Information NOTICE MTE Series RL Line/Load Reactors are components

More information

6" Single Phase Motors 6-10" Three Phase Motors

6 Single Phase Motors 6-10 Three Phase Motors TECHNICAL BROCHURE BCP6-10MTR R2 FEATURES SINGLE PHASE: Single Phase, 6 motors available in 5 15 HP, 230 volt models. Require Control Boxes as shown on Order Number chart. THREE PHASE: Three Phase, 6,

More information

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer

More information

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS Originated 1/85 Revised 6/95 Revised 6/02 Revised 11/05 Revised 4/08 Revised 11/09 Revised 1/12 Revised 11/12 Revised

More information

MERCURY CONTACTORS & RELAYS

MERCURY CONTACTORS & RELAYS MERCURY CONTACTORS & RELAYS PHONE: 704-399-4248 FAX: 704-399-4167 WWW.SETHERMAL.COM INDEX GLOSSARYOFTERMS&EXPRESSIONS...1 GENERALINFORMATIONFEATURES&SELECTIONFACTORS...13 MERCURY TO METAL CONTACTORS AND

More information

112.5 kva Isolation Transformer - 440V Delta Primary - 110V Delta Secondary - NEMA 3R

112.5 kva Isolation Transformer - 440V Delta Primary - 110V Delta Secondary - NEMA 3R 112.5 kva Isolation Transformer 440V Delta Primary 110V Delta Secondary NEMA 3R Part #: MTISX3P440D112.5KVA110DN3R Page: 1 The MTISX3P440D112.5KVA110DN3R 440 V Delta 3 Phase Energy Efficient Distribution

More information

Electropneumatic Timing Relays Series 7000 Industrial

Electropneumatic Timing Relays Series 7000 Industrial DESIGN FEATURES Available in On-Delay, True Off-Delay, and On/Off-Delay. Timing from 0.1 seconds to 60 minutes, fully calibrated in linear increments. Oversize time-calibrated adjustment knobs, serrated

More information

BF Series Flasher Thermal flasher circuitry

BF Series Flasher Thermal flasher circuitry BF Series Flasher Thermal flasher circuitry Long life 2A load rating @ 115V AC Low cost Small size All units work on AC and DC input voltage 3 terminal configuration 6V to 115V input voltages available

More information

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors Made in the U.S.A. NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors Nema Enclosed DC Control Specifications Catalog Number BC140 or Features BC138 BC139 BC140-FBR BC154 BC160 BCWD140

More information

Low Voltage Products. Low Voltage Capacitors Power Factor Correction Solutions

Low Voltage Products. Low Voltage Capacitors Power Factor Correction Solutions Low Voltage Products Low Voltage Capacitors Power Factor Correction Solutions Low Voltage Capacitors Reliability for Power Factor Correction Dry type design The ABB Low Voltage Capacitors, called CLMD,

More information