1 Cable Duct.0 Motor Modules Cable Duct.0 Motor Modules for two V Motorized Rollers Interroll (EC0) resp. RULMECA (RDR BL-) QS and viam8 connectors and via profile cable Flat design, optimized for use in cable channels Inputs and Outputs in one module ASI BW90 Speed setting via parameters (Figure similar) Figure ASI BW90 QS () () () () () Drive () Number of Line drives protection fuse () Flat design, montage in cable duct possible Inputs digital Outputs digital Outputs analog Input voltage (sensor supply) () Output voltage (actuator supply) () connection Interroll, RULMECA out of out of profile cable BW90 Interroll, RULMECA out of out of using M8 BW89 () Article No. Interroll (EC0), RULMECA (RDR BL-): Motor module to control V motorized rollers Interroll Typ EC0 or RULMECA Typ RDR BL-., separately for each motor,, A (slow-blow fuse): In the motor module UL approved fuses are placed before each of the motor supply connections. A short circuit in the motor causes this fuse to blow, protecting the connection cable between the module and motor. After blowing the fuse the module is no longer functional and needs to be replaced. The characteristics of the fuse must be checked against the motor data before using the module. The protection circuit in the module allows a very simple protection of the motor cables. The fuse for the cable protection is a slow-blow one; without short circuit the robust behavior of the module remains. Input voltage (sensor supply): Inputs are supplied by or by (auxiliary V power). If supplied by, inputs shall not be connected to earth or to external potential. Output voltage (actuator supply): Outputs are supplied by or by (auxiliary V power). If supplied by, outputs shall not be connected to earth or to external potential. connection: The connection to as well to (auxiliary V power) is made via yellow resp. black profile cable with piercing technology or via M8 socket. Bihl+Wiedemann GmbH Floßwörthstr. D-6899 Mannheim Phone: (+9) 6/996-0 Fax: (+9) 6/99 mail@bihl-wiedemann.de We reserve the right to change any data Mannheim, 6..6 page

2 Cable Duct.0 Motor Modules Article No. BW90 BW89 General data Roller drives x Interroll (EC0) or x RULMECA (RDR BL-) Connection / connection profile cable and piercing M8 Periphery connection M8 Profile S-7.A.7, ID = 7 (fixed) Address AB slave Required Master profile M As of specification.0 Operating voltage 0 V (8.6 V) Max. current consumption 00 ma Operating voltage V (8 0V) Max. current consumption 6 A continuously, A peak () Input Number x sensor inputs + x motor fault inputs Power supply sensor inputs: out of motor fault inputs: out of Power supply of 00 ma () attached sensors Switching threshold U in <V (low) U in > V (high) Output Number (digital) Number (analog) Power supply out of (galvanic separation) Overvoltage tolerated by reaction () Max. output current Motor supply V resistant brake resistor compatible 0 ma per output, in sum 0 ma at T amb 0 C, ma at T amb >0 C out of, A continuously,, A max. Line protection fuse, separately for each motor,. AT, at 7 A (00%) release between s and 0 s, fuse UL certified () Display LED I...Ix (yellow) state of inputs I, I LED M, M (yellow) state of outputs M (O), M (O) LED ASI (green) on: voltage on off: no voltage LED (green) on: V DC off: no V DC LED FLT/FAULT (red) on: slave address 0 or slave offline flashing: voltage is missing, overload output, an output is short circuited, at least one motor fuse has blown or overload sensor off: slave online Bihl+Wiedemann GmbH Floßwörthstr. D-6899 Mannheim Phone: (+9) 6/996-0 Fax: (+9) 6/99 mail@bihl-wiedemann.de page Mannheim, 6..6 We reserve the right to change any data

3 Cable Duct.0 Motor Modules Article No. BW90 BW89 Environment Applied standards EN EN EN609 Operating altitude max. 000 m Ambient temperature - C C (non-condensing) () () (- C... + C at max., A current consumption) Storage temperature - C C Housing plastic, screw mounting Protection category IP Weight module: 00 g passive distributor: 7 g module: 00 g Dimensions (W / H / D) in mm module: 90 / 60 / 8 passive distributor: 60 / /9 module: 90 / 60 / 8 () Max. current consumption out of (Derating) BW89, BW90 I max. [A] 6,0,0, T amb [ C] () Power supply of attached sensors (Derating) BW89, BW90 I max. [ma] T amb [ C] Bihl+Wiedemann GmbH Floßwörthstr. D-6899 Mannheim Phone: (+9) 6/996-0 Fax: (+9) 6/99 mail@bihl-wiedemann.de We reserve the right to change any data Mannheim, 6..6 page

4 Cable Duct.0 Motor Modules () In the motor module UL approved fuses are placed before each of the motor supply connections. A short circuit in the motor causes this fuse to blow, protecting the connection cable between the module and motor. After blowing the fuse the module is no longer functional and needs to be replaced. The characteristics of the fuse must be checked against the motor data before using the module. The protection circuit in the module allows a very simple protection of the motor cables. The fuse for the cable protection is a slow-blow one; without short circuit the robust behavior of the module remains. internal line protection V ext.in 0 V ext.in M M () If the cables are fixed installed, an operating temperature up to -0 C... + C is permissible. Configuration analog value BW89, BW90 parameters analog value Pin P0 P P O/O , V, V, V,6 V 6,7 V 7,8 V 8,9 V 0 V Bihl+Wiedemann GmbH Floßwörthstr. D-6899 Mannheim Phone: (+9) 6/996-0 Fax: (+9) 6/99 mail@bihl-wiedemann.de page Mannheim, 6..6 We reserve the right to change any data

5 Cable Duct.0 Motor Modules Bit assignment BW90, BW89 Data bit Function DI0 I input I DI I input I DI I state (motor fault) motor DI I state (motor fault) motor DO0 O start/stop motor DO O direction of rotation motor DO O start/stop motor DO O direction of rotation motor Connections M8 BW89 Pins Connection Name / Number Cable length O I analog value M (motor ) (0: 0 V; : V) (0: 0 V; : V) O, cm V ext out 0V O ext out I analog value M (motor ) (0: 0 V; : V) (0: 0 V; : V) O I I 7, cm V out of 0V out of I I in, cm V ext in V ext in 0V ext in 0V ext in in out 0 cm Connections M8 BW90 Pins Connection Name / Number Cable length O I analog value M (motor ) (0: 0 V; : V) (0: 0 V; : V) O, cm V ext out 0V O ext out I analog value M (motor ) (0: 0 V; : V) (0: 0 V; : V) O I I 7, cm V out of 0V out of I I (brown) (blue) (brown) (blue) and via profile cable. The cable length between motor module and passive distributor is cm. Accessories: for BW89: - passive distributor (article no. BW76) for BW90: - connecting cable for addressing with a hand held address programming device (article no. BW0) - connecting cable for addressing with gateways (article no. BW0) Bihl+Wiedemann GmbH Floßwörthstr. D-6899 Mannheim Phone: (+9) 6/996-0 Fax: (+9) 6/99 mail@bihl-wiedemann.de We reserve the right to change any data Mannheim, 6..6 page

Cable Duct AS-i 3.0 Motor Modules

Cable Duct AS-i 3.0 Motor Modules Cable Duct.0 Motor Modules Cable Duct.0 Motor Modules for two V Motorized Rollers Itoh Denki (PM00ME/XE/XP, PM60ME/XE/XP) M M ASI FLT I I I I and via M8 connectors BW9 and via profile cable Flat design,

More information

Passive Distributor AS-i, IP67

Passive Distributor AS-i, IP67 Passive Distributor AS-i s for profile cables AS-i/ x AS-i/ to M8 cable sockets to M sockets / cable sockets to connecting wires as profile cable branch (figure similar) optionally with changeable or self-resetting

More information

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information Segment Terminal Fused, with Diagnostics 24VDC Segment Terminal module is used to create a protected partial circuit (segment circuit) within the main circuit. It is not used to supply power and has no

More information

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document. General information Actuator controls AC 01.2 for controlling multi-turn actuators of the SA/SAR type range and part-turn actuators of the SQ/SQR.2 type range. Features and functions Power supply Standard

More information

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC Inline Power Terminal With Fuse and Diagnostics Data Sheet 5569C 02/2003 # # $ ' ) The IB IL 24 PWR IN/F-D and IB IL 24 PWR IN/F-D-PAC only differ in the scope

More information

EPS/ELA-Series User Manual EPS/ELA 250W

EPS/ELA-Series User Manual EPS/ELA 250W EPS/ELA-Series User Manual EPS/ELA 250W EPS Stromversorgung GmbH Tel: +49 (0)821 570451 0 Index 3 Page: 1 Table of contents: Page 1. Features of ELA-Series... 3 1.1 Basic Functions... 3 1.2 Options...

More information

AC drive has detected too high a Check loading

AC drive has detected too high a Check loading Fault code Fault Name Fault type Default Possible Cause Remedy 1 Over Current Fault AC drive has detected too high a Check loading current (>4*IH) in the motor cable: Check motor Sudden heavy load increase

More information

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies General information Actuator controls AC 01.2 for controlling multi-turn actuators of the SA/SAR type range and part-turn actuators of the SQ/SQR.2 type range. Power supply Standard voltages AC: 3-phase

More information

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD General information AC 01.2 Actuator controls in SIL version for controlling multi-turn actuators of the SA/SAR.2 type range and part-turn actuators of the SQ/SQR.2 type range. Information on SIL features

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver LC 65W 4-7mA flexc lp ANCED series Product description Built-in constant current LED Driver Adjustable output current between 4 and 7 ma Max. output power 65 W Up to 94 % efficiency Nominal life-time

More information

BLU SERIES Battery Load Units

BLU SERIES Battery Load Units BLU SERIES Battery Load Units Lightweight starting from 12,8 kg (28.2 lbs) Powerful discharge power of up to 28,4 kw Voltage measurement range: 5,25-500 V DC Discharge current up to 340 A DC Easily expandable

More information

Process controller. for pneumatic and electric actuators. Process controller V. Process controller

Process controller. for pneumatic and electric actuators. Process controller V. Process controller for pneumatic and electric actuators Process controller 110-240V Process controller dtron 316 in Rittal-cabinet with current loop sensor input for controlling pneumatic and electric actuators with a position

More information

DEVICE STATE/BYPASSED FAILURE OVERLOAD

DEVICE STATE/BYPASSED FAILURE OVERLOAD Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated

More information

RUZ- _/_ Protection (3) Isolation Option (4)

RUZ- _/_ Protection (3) Isolation Option (4) Features Unregulated Converters Description Dual output from a single input rail 1kVDC or 2kVDC input/output basic isolation 1kVDC output/output isolation Power sharing on outputs Optional continuous short

More information

JUMO ecotrans Lf 01/02

JUMO ecotrans Lf 01/02 Data Sheet 07 Page /7 JUMO ecotrans Lf 0/0 Microprocessor Transmitter/Switching Device for Conductivity Housing for DIN rail mounting (5 mm 7.5 mm to EN 075 A.) Brief description The JUMO ecotrans Lf 0/0

More information

Regenerative DC Common Bus Supply

Regenerative DC Common Bus Supply Regenerative DC Common Bus Supply The Regenerative DC Common Bus Supply supplies both motoring and regenerative current to the DC bus of one or more AC drives without the need of rectifier front end in

More information

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.: Extract from the online catalog MINI-DC-UPS/24DC/2 Order No.: 2866640 Uninterruptible power supply with integrated power supply unit, 2 A, in combination with MINI-BAT/24/DC 0.8 AH or 1.3 AH Commercial

More information

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox Characteristics brushless dc motor 24..36 V - CANopen DS301 interface - L = 122 mm - w/o gearbox Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Network

More information

Electric actuators type EA25-250

Electric actuators type EA25-250 Electric actuators type EA25-250 Small & Light Product description The actuators type EA25, EA45, EA120 and EA250 are not only excellently equipped, they also feature very high peak torques ranging from

More information

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog Low voltage AC drives ABB micro drives ACS55 0.25 to 3 hp/0.18 to 2.2 kw Catalog ACS55 IP20 Overview ACS55 micro drives are designed for use in a wide variety of simple machinery applications where only

More information

*-JBSC-* Fieldbus junction box with integrated short-circuit current limitation

*-JBSC-* Fieldbus junction box with integrated short-circuit current limitation Fieldbus Segment Protector Fieldbus junction box with integrated short-circuit current limitation Type code see overleaf Connection Shielding variations Main cable Trunk N Fieldbus distributor with individually

More information

Compact I/O modules (IP20)

Compact I/O modules (IP20) Bus module MBK Thanks to its compact construction, the bus module MBK (IP20) can be easily mounted in shallow control panels, terminal boxes and distribution boxes. The simple construction with the lowest

More information

MANUAL. MiniMax V / VK

MANUAL. MiniMax V / VK MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER MiniMax V / VK Revised 2014-10-07 Version 1.3.1 F21037901GB Declaration of Manufacturer The manufacturer s assurance of the agreement of the product with

More information

Positive displacement batch controller

Positive displacement batch controller 8075 Batch controller Positive displacement batch controller Type 8075 can be combined with... Compact version for DN15 to DN100 Dosing On site calibration by Teach-In Check of input/output signals Total

More information

JUMO MIDAS S05 Pressure transmitter Type

JUMO MIDAS S05 Pressure transmitter Type Data Sheet 40.00 Page /8 JUMO MIDAS S05 Pressure transmitter Type 4000 Brief description The JUMO MIDAS S05 pressure transmitter is available with both relative pressure and absolute pressure measurement

More information

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER. MicroMax. Article no. F IBC control Made in Sweden

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER. MicroMax. Article no. F IBC control Made in Sweden MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER MicroMax Article no. F21009201 IBC control Made in Sweden TABLE OF CONTENTS Installation instructions 2 Mounting 2 Safety instructions 3 Manufacturer's

More information

ILE1F661PB1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

ILE1F661PB1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox Characteristics brushless dc motor 24..36 V - CANopen DS301 interface - L = 122 mm - w/o gearbox Product availability : Stock - Normally stocked in distribution facility Price* : 840.00 USD Main Range

More information

The motor starter on the power bus. Solutions for conveyor technology. Full speed ahead

The motor starter on the power bus. Solutions for conveyor technology. Full speed ahead The motor starter on the power bus Solutions for conveyor technology The motor starter on the power bus Full speed ahead The system solution The motor starter on the power bus The motor starter The podis

More information

Low voltage AC drives

Low voltage AC drives General machinery drives Main features and dimensions Unique features Fast and extensive I/O PID control Application macros Many installation possibilities 200 to 480 V, 1-phase or 3-phase More value for

More information

Power Electronics. MINISTOP Motor Brake Relay BA 9034N

Power Electronics. MINISTOP Motor Brake Relay BA 9034N Power Electronics IISTOP otor Brake Relay BA 9034 0256981 Your advantages Higher safety level and more economic by short stopping cycle Cost saving Compact design Easily appliance, no need for current

More information

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series Driver LC 150W 200 1050mA IND sl EXC EXCITE series Product description Constant current built-in Driver for LED, particularly suitable for industrial applications in tough environments such as cold warehouses

More information

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1 Characteristics brushless dc motor 24..48V- EtherNet/IP interface - L = 174 mm- 18:1 Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Network number

More information

IBC control. MicroMax MANUAL. With adjustable boost function and threshold value. Since Set of EMC-glands as an option

IBC control. MicroMax MANUAL. With adjustable boost function and threshold value. Since Set of EMC-glands as an option Made in Since 1983 S w e d e n MANUAL Set of EMC-glands as an option CONTROL UNIT FOR ROTARY HEAT EXCHANGER MicroMax Article no. F21009301 With adjustable boost function and threshold value IBC control

More information

Electrical Engineering Info

Electrical Engineering Info Electrical Engineering Info Ready for the New ErP Directives: With Energy- Efficient Solutions for Electric Motors Effective EU regulation EC 640/2009 1.1.2015 Eaton Drives engineering Start IE3 motors

More information

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor. Page 1/8 JUMO thermocor Portable measuring system for AMS2750 and CQI-9 Brief description The JUMO thermocor is a high-precision documenting test device with 12 analog inputs for thermocouples. The use

More information

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control Document No. 155-507 Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control Description The Flowrite 599 Series SAX Non-spring Return (NSR), Electronic Valve Actuator

More information

Order No. of the options EMC filter Class A

Order No. of the options EMC filter Class A Ordering Data for Variant Dependent Options The options listed here (filters, chokes, brake resistors, gland plates, fuses and circuit breakers) are inverter specific. The inverter and the associated options

More information

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series Product description Fixed output constant current built-in LED Driver, particularly suitable for industrial applications in tough enviromments such

More information

See «Overview of types»

See «Overview of types» echnical data sheet SHA-.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. 3 m Actuating

More information

sinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004

sinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004 Variable Speed Drives 0.12 kw to 3 kw Short Form 2004 sinamics SINAMICS Variable Speed Drives 0.12kW to 3kW Product Information Pricing The is a Variable Speed Drive with basic functions for a variety

More information

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector Characteristics integrated drive ILA with servo motor - 24..48 V - DeviceNet - indus connector Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Phase

More information

DC/DC converters - MINI-PS DC/ 5-15DC/

DC/DC converters - MINI-PS DC/ 5-15DC/ Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid

More information

QS20.241, QS C1

QS20.241, QS C1 QS2.21, QS2.21C1 QSeries 27. APPLICATION NOTES 27.1. REPETITIVE PULSE LOADING Typically, a load current is not constant. It varies over time. For pulse load compatibility, following rules must be met:

More information

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz GR24A-5 / -7 GR24A-5 Rotary actuator for rotary valves GR24A-7 Rotary actuator for rotary valves Nominal torque 40Nm Nominal voltage AC/DC 24V Control Open-close echnical data Electrical data Nominal voltage

More information

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, 4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en

More information

J1000. Compact Inverter Series.

J1000. Compact Inverter Series. J1000 Compact Inverter Series www.yaskawa.eu.com Focus on Application Customer orientation and application focus two attributes of machine equipment YASKAWA offers with its J1000 compact inverter drive

More information

ILA1F572PB1F0 integrated drive ILA with servo motor V - CANopen - PCB connector

ILA1F572PB1F0 integrated drive ILA with servo motor V - CANopen - PCB connector Characteristics integrated drive ILA with servo motor - 24..36 V - CANopen - PCB connector Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 1860.00 USD Main Range

More information

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9. SED2 with Conventional Bypass Options Important Note: VD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies

More information

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0 Products Tde Macno User s Manual BRAKING UNIT Cod. MP00401E00 V_1.0 SUMMARY 1 GENERAL DESCRIPTION... 2 2 USE LIMITATIONS... 2 2.1 Climatic Class... 2 2.2 Resistance To Chemically Active Substances...

More information

Contents. Part no.: MLC510R Safety light curtain receiver

Contents. Part no.: MLC510R Safety light curtain receiver Part no.: 68001315 MLC510R30-1500 Safety light curtain receiver Figure can vary Contents Technical data Suitable transmitters Dimensioned drawings Electrical connection Circuit diagrams Operation and display

More information

ILE1B661PC1A1 brushless dc motor V - Profibus DP interface - L = 174 mm - 18:1

ILE1B661PC1A1 brushless dc motor V - Profibus DP interface - L = 174 mm - 18:1 Characteristics brushless dc motor 24..36 V - Profibus DP interface - L = 174 mm - 18:1 Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 1640.00 USD Main Range

More information

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Quick guide. Plug-in fans GPPM with FC101_106 August 2014 Quick guide Plug-in fans GPPM with FC101_106 August 2014 Fläkt Woods permanent magnet motors and speed controllers for plug fans GPPM 1. General Fläkt Woods offers a wide range of permanent magnet motors

More information

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE Speed Sensor ã Read and understand equipment operators manual before operating or performing maintenance. Failure to do so could result in serious injury or death. Safety Information Failure to follow

More information

The smd frequency inverter Compact, powerful, without compromise simply smart

The smd frequency inverter Compact, powerful, without compromise simply smart The smd frequency inverter Compact, powerful, without compromise simply smart smart micro drive The compact smd for large tasks 2 Do you work with digital and analog inputs, preset speeds or a display

More information

JC-VSD FP Series II Drives Product Bulletin 1

JC-VSD FP Series II Drives Product Bulletin 1 JC-VSD FP Series II Drives Product Bulletin Code No. LIT-12012081 Issued May 2017 The Johnson Controls VSD FP Series II provides the advanced technology and features of the Johnson Controls VSD Series

More information

Versatile and Powerful

Versatile and Powerful AM Series Direct Coupled Actuator Versatile and Powerful Minimum 180 in-lb torque in a compact package. For damper areas up to 45 sq-ft* All Actuators have BDCM AM Series - At A Glance AMB(X)24-3 (p. 148)

More information

POWER SUPPLY aps-412_en 06/16

POWER SUPPLY aps-412_en 06/16 APS-412 POWER SUPPLY aps-412_en 06/16 The APS-412 switching power supply has been designed for use with 12 V DC electrical devices. It comes with a dedicated connector allowing for integration with Satel's

More information

Brake Chopper BC BC 4.1. Instruction and Operation Manual

Brake Chopper BC BC 4.1. Instruction and Operation Manual Brake Chopper BC 2.1 - BC 4.1 Instruction and Operation Manual Caution: There is always a risk involved in the handling of electrical machinery! Therefore mounting and maintenance should only be done by

More information

(typ.) (Range) ±18 330# 89 MPW MPW

(typ.) (Range) ±18 330# 89 MPW MPW DC/DC 30W, Single & Dual Output FEATURES 2 x 1.6 x 0.4 Metal Package Ultra-wide 4:1 Input Range Operating Temp. Range 40 C to 80 C Short Circuit Protection I/O-isolation 1500 VDC Input Filter meets EN

More information

DC POWER SUPPLY ALIMENTATION C.C.

DC POWER SUPPLY ALIMENTATION C.C. DC POWER SUPPLY ALIMENTATION C.C. ISO-TECH IPS 303A 201-3424 ISO-TECH IPS 601A 201-3446 SAFETY TERMS AND SYMBOLS These terms may appear in this manual or on the product: WARNING. Warning statements identify

More information

TECHNICAL BROCHURE BAQUACPC. Aquavar CPC VARIABLE SPEED CENTRIFUGAL PUMP CONTROLLER

TECHNICAL BROCHURE BAQUACPC. Aquavar CPC VARIABLE SPEED CENTRIFUGAL PUMP CONTROLLER TECHNICAL BROCHURE BAQUACPC Aquavar CPC VARIABLE SPEED CENTRIFUGAL PUMP CONTROLLER Introduction The Aquavar CPC (Centrifugal Pump Controller) from incorporates the latest state-of-the-art Aquavar technology,

More information

ILE2T661PB1A3 brushless dc motor V - Modbus TCP interface - L = 174 mm - 54:1

ILE2T661PB1A3 brushless dc motor V - Modbus TCP interface - L = 174 mm - 54:1 Characteristics brushless dc motor 24..48 V - Modbus TCP interface - L = 174 mm - 54:1 Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 1540.00 USD Main Range of

More information

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Proportional directional valve, pilot-operated, with integrated electronics (OBE) Proportional directional valve, pilot-operated, with integrated electronics (OBE) Type WFCE RE 943 Edition: 7- Replaces: 6- Size 6 5 Component series X Maximum operating pressure 4 bar Maximum flow 5 l/min

More information

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity Data Sheet 20.27 Page / ecotrans Lf 0/02 Microprocessor Transmitter / Switching Device for Conductivity Type 2027 Housing for DIN rail mounting (5 x 7.5 mm to EN 0 75 A.) Brief description The JUMO ecotrans

More information

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10 our name is our principle UV- TECHNOLOGY Technical Documentation ELC N6 / ELC N8 / ELC N10 GB eta plus electronic gmbh Lauterstraße 29, D-72622 Nürtingen, Telefon +49 (0) 70 22-60 02-80, Fax +49 (0) 70

More information

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP Phoenix DX Sensorless AC Vector Drive 3 HP to 3500 HP Standard Features: * PRECISE CONTROL OF MOTOR SPEED AND TORQUE * BI-DIRECTIONAL FLYCATCHER (CATCH SPINNING MOTOR) * EASY TO USE, SIMPLE SETUP * POWER

More information

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp VS1MX AC Micro Drive 1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp & Controls 115 VAC 230 VAC 230 VAC 460 VAC 1 Phase - 50/60 Hz 1 Phase - 50/60 Hz 3 Phase - 50/60 Hz 3 Phase - 50/60 Hz Applications:

More information

FACTORY AUTOMATION. System Accessories for Mounting and Connection

FACTORY AUTOMATION. System Accessories for Mounting and Connection FACTORY AUTOMATION System Accessories for Mounting and Connection Installing sensors simply and economically! Suitably tailored accessories for the fixing and connection of sensors offer the user enormous

More information

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf % Doc. EC-0093 FEATURES Industrial Standard 2"x1" Package Ultra-wide Input Range 9-36VDC, 18-75VDC, 40-160VDC I/O Isolation 3000VAC with Reinforced Insulation Operating Ambient Temp. Range -40 C to +88 C

More information

Piston Pumps with Reservoir

Piston Pumps with Reservoir Piston Pumps with Reservoir 1-0107-2-US for grease up to NLGI grade 2 with electric drives for progressive and multiline systems KFA1 / KFA10 KFG1-5-W2-M KFGS30-5 Because of their delivery rates and reservoir

More information

Electronic Circuit Breaker ESS20

Electronic Circuit Breaker ESS20 Electronic Circuit Breaker ESS20 Description Electronic circuit breaker type ESS20 is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 24 V switch-mode

More information

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw CATALOG ABB micro drives ACS55, 0.18 to 2.2 kw 2 ABB MICRO DRIVES, ACS55, 0.18 TO 2.2 KW/0.25 TO 3 HP Ease of integration. ACS55 drives. 3 Table of contents 004 ABB micro drives, ACS55 005 Easily integrated

More information

Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses

Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses Type 8644 can be combined with... Fully compatible with WAGO I/O Combination of Fieldbus, pilot valves and I/O modules High

More information

Installation and User Guide CCMS312

Installation and User Guide CCMS312 SEITE 1 Installation and User Guide CCMS312 Description The charging current management system CCMS312 is used as a control unit for up to 8 emh1 (EVCC). Functions of the CCMS312: Simple load management

More information

Actual-position Feedback Unit. SISTO-SK-i. For Valves with Linear Actuators Stroke: 5-46 mm. Type Series Booklet

Actual-position Feedback Unit. SISTO-SK-i. For Valves with Linear Actuators Stroke: 5-46 mm. Type Series Booklet SISTO-SK-i For Valves with Linear Actuators Stroke: 5-46 mm Type Series Booklet Legal information/copyright Type Series Booklet SISTO-SK-i All rights reserved. The contents provided herein must neither

More information

Product series DSA, DSB, DSC, DSD

Product series DSA, DSB, DSC, DSD Pressure Switches Product series DSA, DSB, DSC, DSD For oil, fluid grease and grease For use in SKF centralized lubrication systems, hydraulic and compressed-air systems DSA DSB DSC SKF pressure switches

More information

Inductive conductivity meter

Inductive conductivity meter Inductive conductivity meter Type 8228 can be combined with... Configurable outputs: up to 2 transistor and up to 2 analog 4... 20 ma outputs Removable backlighted display Simulation of process values

More information

Technical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids

Technical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids Technical Data Low Voltage Regulation System LVRSys 1 Power range: 7.5 kva up to 3150 kva 1 Regulation: single- or three-phase 1 Regulation ranges: ± 6 % to ± 24 % 1 Overall efficiency: 99.4 % to 99.8

More information

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

SINUS PENTA 2T/4T SINUS PENTA 2T/4T SINUS PENTA 2T/4T SINUS PENTA 2T/4T Technical Highlights One product, 5 integrated functions - IFD (Inverter Frequency Drive): vector modulation function for general-purpose applications (V/F pattern).

More information

Minimum 27 in-lb torque

Minimum 27 in-lb torque LU Series Actuator Minimum 27 in-lb torque For damper areas up to 6.8 sq-ft* All Actuators have BDCM LU Series - At A Glance LUB(X)24-3 (p. 258) LUB(X)24-SR (p. 260) LUX24-MFT (p. 262) Basic Product Flexible

More information

BLU SERIES Battery Load Units

BLU SERIES Battery Load Units BLU SERIES Battery Load Units Lightweight starting from 12,8 kg (28.2 lbs) Powerful discharge power of up to 28,4 kw Voltage measurement range: 5,25-500 V DC Discharge current up to 340 A DC Easily expandable

More information

LED Driver Compact fixed output

LED Driver Compact fixed output Driver LC 45W 500 1400mA flexc SC EXC EXCITE series Product description Constant current LED Driver Dimmable via ready2mains Gateway Dimming range 15 100 % (Depending on load. For details refer to chapter

More information

500 / 630 / 720 / 760 / 800 / 850 / 900

500 / 630 / 720 / 760 / 800 / 850 / 900 SUNNY CENTRAL STORAGE 500 / 630 / 720 / 760 / 800 / 850 / 900 SCS 500 / SCS 630 / SCS 720 / SCS 760 / SCS 800 / SCS 850 / SCS 900 Durable Full nominal power in continuous operation at ambient temperatures

More information

LED Driver Compact fixed output

LED Driver Compact fixed output Driver LC 25W 350 1050mA flexc SC EXC EXCITE series Product description Constant current LED Driver Dimmable via ready2mains Gateway Dimming range 15 100 % (Depending on load. For details refer to chapter

More information

ALTIVAR FLEX58 Chassis Drive Controller Product Selection

ALTIVAR FLEX58 Chassis Drive Controller Product Selection ALTIVAR FLEX58 Chassis Drive Controller Product Selection Class 8806 CONTENTS Description Page General Information and Selection....................................... 2 Specifications and Ratings...........................................

More information

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2. FEATURES Industrial Standard 2" X 1" Package Wide 2:1 Input Voltage Range Fully Regulated Output Voltage High Efficiency up to 88% I/O Isolation 1500 VDC Operating Ambient Temp. Range -40 to 85 Overload

More information

Vehicle inlet - EV-T2GBIE12-1ACDC-20A125A2,0M

Vehicle inlet - EV-T2GBIE12-1ACDC-20A125A2,0M Vehicle Inlet for charging with alternating current (AC) and direct current (DC), for installation in electric vehicles (EV), CCS type 2, Combined Charging System, IEC 62196-3, 125 A / 850 V (DC), 20 A

More information

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series /,, MODEL SELECTION TABLE INPUT ORDER NO. INPUT VOLTAGE (RANGE) NO LOAD INPUT CURRENT FULL LOAD VOLTAGE CURRENT EFFICIENCY (TYP.) CAPACITOR LOAD (MAX.) SPBW06F-03 310mA 3.3V 0 ~ 1500mA 81% 4700μF SPBW06F-05

More information

INVEOR "Smart connections." on five levels

INVEOR Smart connections. on five levels INVEOR "Smart connections." on five levels 1 The Inveor 3 Operation and observation IP65 protection class Integrated soft PLC Pre-fitted cable glands Fan-free design up to 7.5 kw Robust and vibration-resistant

More information

Possible to create the highest level safety system

Possible to create the highest level safety system 14 LIGHT CURTAIS (For PP output type light curtain) Control category 4 Possible to create the highest level safety system Conforming to achine Directive & C Directive Approved Listing Compatible up to

More information

720 W / 24 V On-board Battery Charger. for industrial applications. Product Data Sheet

720 W / 24 V On-board Battery Charger. for industrial applications. Product Data Sheet for industrial applications Product Data Sheet 720 W / 24 V On-board Battery Charger for industrial applications Features IP65 protection degree Battery selection via GUI, supporting all leading battery

More information

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor. sales@jumo.co.uk info.us@jumo.net Page 1/8 JUMO thermocor Portable measuring system for AMS2750 and CQI-9 Brief description The JUMO thermocor is a high-precision documenting test device with 12 analog

More information

Safety technique. Emergency Stop Module BH 5928, BI 5928

Safety technique. Emergency Stop Module BH 5928, BI 5928 Safety technique Emergency Stop Module BH 5928, BI 5928 with time delay safemaster 0226419 Function diagram According to EU directive for machines 98/37/EG According to IEC/E 60 204, E 954-1 Safety category

More information

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN Safety Interlock Switches D4B- N D4BN Safety Limit Switch Snap-action contact with certified direct operation. mechanism (NC contacts only) added to enable contacts when faults occur, such as fused contacts.

More information

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web:  - MAKING MODERN LIVING POSSIBLE Quick Setup VLT FCM 300 Series Factory setting Motors type B14 & B34 mounting Reset (pushbutton) Start Jog Speed reference Fig. 1 - Reset to be closed short time for resetting

More information

Number 1 in efficiency

Number 1 in efficiency PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter The

More information

Communication module. Brief description. Block structure Features. Page 1/5. Data Sheet

Communication module. Brief description. Block structure Features. Page 1/5. Data Sheet M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 (0) 661 60 03-7 25 Fax: +49 (0) 661 60 03-6 81 E-Mail: mail@jumo.net

More information

Lexium integrated drives

Lexium integrated drives Description ILp for DeviceNet, EtherCAT, Modbus TCP, ILE with brushless DC motor Description ILE comprise control electronics with a fieldbus interface for DeviceNet, EtherCAT, Modbus TCP or and a brushless

More information

SAX Electronic Valve Actuator

SAX Electronic Valve Actuator SAX Electronic Valve Actuator Non-spring Return, 24 Vac, Proportional Control Technical Instructions Document No. 155-506 Description The SAX Non-spring Return (NSR), Electronic Valve Actuator requires

More information

IB IL 24 SEG/F. Function. INTERBUS Inline Segment Terminal With Fuse. Data Sheet 5656B

IB IL 24 SEG/F. Function. INTERBUS Inline Segment Terminal With Fuse. Data Sheet 5656B INTERBUS Inline Segment Terminal With Fuse Data Sheet 5656B 02/2001 # $ # $ ) This data sheet is intended to be used in conjunction with the Configuring and Installing the INTERBUS Inline Product Range

More information