Passive Distributor AS-i, IP67

Size: px
Start display at page:

Download "Passive Distributor AS-i, IP67"

Transcription

1 Passive Distributor AS-i s for profile cables AS-i/ x AS-i/ to M8 cable sockets to M sockets / cable sockets to connecting wires as profile cable branch (figure similar) optionally with changeable or self-resetting fuses Figure Type Flat design, montage in cable duct possible mm no mm mm no no - Internal fuse () A, changeable A, self-resetting 9 mm yes 8 A slow-blow fuse + A, self-resetting Profile cable x AS-i, x AS-i, x AS-i, x AS-i, 9 mm yes A, self-resetting x AS-i, 9 mm yes - x AS-i, () Cable () Protection category Article no. x M sockets, -poles - IP67 BW087 x M sockets, -poles - IP67 BW7 x M sockets, -poles - IP67 BW8 x straight, -poles + x straight, -poles 0,0 m IP67 BW76 x M cable socket, angled, -poles m IP67 BW6 x M cable socket, angled, -poles m IP67 BW8 yes - x AS-i x M cable socket, angled, -poles m IP67 BW8 9 mm yes - x AS-i x M cable socket, straight, -poles m IP67 BW7 9 mm yes - x AS-i x round cable / connecting wires 0, m IP67 BW86 9 mm yes - x AS-i profile cable branch - IP67 BW7 9 mm () Internal fuse A, changeable: The internal protection is realized via changeable A fuses (slow-blow) for AS-i and. At each M A are available. A, self-resetting: The internal protection is realized via self-resetting A fuses for AS-i and. At each M A are available. 8 A slow-blow fuse + A, self-resetting: The internal protection is realized via one 8 A slow-blow fuse for and via one self-resetting A fuse for AS-i. At each M8 () 6 A are available, at each M8 (AS-i) A are available. () : further options are available on request. M cable socket, angled M cable socket, straight straight round cable / connecting wires PUR line: oil and abrasion resistant, appropriate for conveyor chains profile cable branch () Cable: other cable lengths are available on request. Bihl+Wiedemann GmbH Floßwörthstr. D-6899 Mannheim Phone: (+9) 6/996-0 Fax: (+9) 6/99 mail@bihl-wiedemann.de We reserve the right to change any data Mannheim,.. page

2 Article No. BW8 BW087 BW7 BW6 BW76 Profile cable x AS-i, x piercing x M sockets, -poles x Mcablesocket, angled, -poles x straight, -poles x straight, -poles Cable m 0,0 m max. allowed tensile strain 0 N Operating voltage 0... V DC PELV Operating current A at each M A at each M 6 A at each M8 () A at each M8 (AS-i) Internal fuse - x A changeable fuses for AS-i and for each M Display LED ASI, ASI (green) - on: AS-i voltage at M, LED AU, (green) - on: voltage at M, x A self-resetting fuses for AS-i and for each M on: AS-i voltage at M on: voltage at M x 8A slow-blow fuse for + x A self-resetting fuse for AS-i on: AS-i voltage at M8 on: voltage at M8 LED ASI (green) on: AS-i voltage at profile cable LED (green) on: voltage at profile cable Environment Applied standards EN 609 EN EN Operating altitude max. 000 m Ambient temperature -0 C +70 C -0 C + C Storage temperature -0 C +8 C Housing plastic, for screw mounting plastic, for screw mounting, suitable for cable ducts Protection category IP67 Maximum tolerable shock and vibration stress Insulation voltage g, T ms 0... Hz, 0, mm amplitude 00 V Weight 9 g 7 g Dimensions (W / H / D) in mm 60 / / 60 / / 9 Bihl+Wiedemann GmbH Floßwörthstr. D-6899 Mannheim Phone: (+9) 6/996-0 Fax: (+9) 6/99 mail@bihl-wiedemann.de page Mannheim,.. We reserve the right to change any data

3 Article No. BW7 BW86 BW7 BW8 BW8 Profile cable x AS-i piercing x AS-i, x piercing profile cable branch x round cable / connecting wires x Mcablesocket, straight, -poles Cable 0, m m max. allowed tensile strain 0 N Operating voltage 0... V DC PELV Operating current piercing: 8 A piercing: 8 A piercing: 8 A A at each round A at each M cable / connecting wires Internal fuses Environment Applied standards EN 609 EN EN Operating altitude max. 000 m Ambient temperature -0 C +70 C Storage temperature -0 C +8 C Housing plastic, for screw mounting, suitable for cable ducts Protection category IP67 Maximum tolerable shock and vibration stress Insulation voltage Weight Dimensions (W / H / D) in mm g, T ms 0... Hz, 0, mm amplitude 00 V 7 g 60 / / 9 x M cable socket, angled, -poles A at each M Notice After each opening of the module, such as after replacing a fuse, check for proper function and correct placement of the seals. Dirt, damage and/or shifting of the seals can compromise protection of the module against solid particles and liquids so that the specified protection category is no longer guaranteed. Internal fuses BW087 F F Position of changeable fuses BW F F Bihl+Wiedemann GmbH Floßwörthstr. D-6899 Mannheim Phone: (+9) 6/996-0 Fax: (+9) 6/99 mail@bihl-wiedemann.de We reserve the right to change any data Mannheim,.. page

4 Passive Distributor AS-i, IP67 s Article No. M Pin Pin Pin Pin - AS-i - + Pin BW087, BW7, BW8 AS-i - AS-i AS-i - + BW8 - AS-i - + AS-i - BW8, BW7 AS-i -i BW6 (brown) (blue) BW86 BW7 s Article No. M8 Pin Pin Pin Pin Pin ASI BW BW76 Bihl+Wiedemann GmbH Floßwörthstr. D-6899 Mannheim Phone: (+9) 6/996-0 Fax: (+9) 6/99 mail@bihl-wiedemann.de page Mannheim,.. We reserve the right to change any data

5 Accessories: Protection caps for unused M sockets (article no. BW68) Sealing profile IP67 (IDC plug), 60 mm (article no. BW8) Bihl+Wiedemann GmbH Floßwörthstr. D-6899 Mannheim Phone: (+9) 6/996-0 Fax: (+9) 6/99 mail@bihl-wiedemann.de We reserve the right to change any data Mannheim,.. page

Cable Duct AS-i 3.0 Motor Modules

Cable Duct AS-i 3.0 Motor Modules Cable Duct.0 Motor Modules Cable Duct.0 Motor Modules for two V Motorized Rollers Itoh Denki (PM00ME/XE/XP, PM60ME/XE/XP) M M ASI FLT I I I I and via M8 connectors BW9 and via profile cable Flat design,

More information

Cable Duct AS-i 3.0 Motor Modules

Cable Duct AS-i 3.0 Motor Modules Cable Duct.0 Motor Modules Cable Duct.0 Motor Modules for two V Motorized Rollers Interroll (EC0) resp. RULMECA (RDR BL-) QS and viam8 connectors and via profile cable Flat design, optimized for use in

More information

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5 .1 AZM 11 range Features Thermoplastic enclosure Manual and emergency release Long life Double insulated X High holding force, N N latching force Wiring compartment Actuation on de-energisation or energisation

More information

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from Omron STI Application Support Thank you for your interest in Omron STI products. Please contact Omron STI with your application questions. Support Engineers are available at our USA headquarters from 4:00

More information

PEL power supplies. 24 Vdc 18 Vdc 12 Vdc SWITCHED MODE POWER SUPPLIES/ PEL SERIES

PEL power supplies. 24 Vdc 18 Vdc 12 Vdc SWITCHED MODE POWER SUPPLIES/ PEL SERIES power supplies Our powerful miniature units ensure optimum power supply for miniature controllers. Versions with a 12, 18 and 24 V output voltage are available, enabling them to be used in a whole range

More information

Electronic Braking Systems

Electronic Braking Systems Technical Details Electronically-controlled compact braking system for three-phase asynchronous motors Features Brake for preset time or brake until standstill can be set using the effective value Adjustable

More information

Manual Reset Limit Switch

Manual Reset Limit Switch Manual Reset Limit Switch A Series of Pull-reset Models Available Ideal for elevators (EN81), escalators (EN115), and conveyors. Positive opening mechanism insulation approved by TÜV and BIA. and double

More information

A c c e s s o r i e s

A c c e s s o r i e s Accessories CEE-ACCESSORIES Mounting Frame For attaching panel mounting socket outlets a b c d e Fig.: Type 19 30 MB 1 50 50 3 3 13 5 5 10 17 57 7 7 10 1 0 0 50 50 10 19 5 5 10 150 70 5 0 10 151 Mounting

More information

Technical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids

Technical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids Technical Data Low Voltage Regulation System LVRSys 1 Power range: 7.5 kva up to 3150 kva 1 Regulation: single- or three-phase 1 Regulation ranges: ± 6 % to ± 24 % 1 Overall efficiency: 99.4 % to 99.8

More information

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel Raised design Emergency-stop switch, foolproof EN IEC 60947-5-5, IP 65 Equipment consisting of (schematic overview) L1 35.6 6 max. 59.5 41 18x24 Actuator Product can differ from the current configuration.

More information

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA P Temperature monitoring (PTC) Short-circuit monitoring Supply voltage 24-240 V AC/DC 1 normally open contact Width 22,5 mm Status indication LED U: Supply voltage LED TFailure: Temperature failure TECHNICAL

More information

Pre wired limit switches

Pre wired limit switches Pre wired limit switches Selection diagram Actuators A B B 9 BL Thermoplastic Bodies E7 I s NO+NC snap action NO+NC slow action Cable entry 4 or 5 pole PVC sheath cable (standard) M connector AMP connector

More information

Hinged Safety Door Switch

Hinged Safety Door Switch Hinged Safety Door Switch Polymer housing, IP65, and slow-action contacts with positive opening. Two actuator types are available: Shaft Arm lever Arm lever type can be adjusted to allow a right (180 ),

More information

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal PCB Relay Ultracompact, Ultrasensitive DPDT Relay Compact size and low 5-mm profile. Low power consumption (140 mw for single-side stable, 100 to 300 mw for latching type) and high sensitivity. Low thermoelectromotive

More information

JUMO MIDAS Pressure transmitter

JUMO MIDAS Pressure transmitter Phone: +44 19 635533 Fax: +44 19 6356 Data Sheet 401001 Page 1/5 JUMO MIDAS Pressure transmitter Brief description Pressure transmitters are used for measuring the relative (gauge) pressure in liquids

More information

Safety Limit Switch

Safety Limit Switch Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_5_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit

More information

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S PCB Relay Surface Mounting DPDT Relay Long terminals for ideal for soldering and mounting reliability. Space-saving inside-l terminal. High dielectric strength between coil and contacts (2,000 VAC), and

More information

Push-in RTD Temperature Probe with Connecting Cable

Push-in RTD Temperature Probe with Connecting Cable Data Sheet 902150 Page 1/6 Push-in RTD Temperature Probe with Connecting Cable Temperature range from -50 to +400 C As single or double RTD temperature probe In 2-wire, 3-wire or 4-wire-circuit Connecting

More information

Safety door-handle system STS

Safety door-handle system STS Safety door-handle system STS Full body access ha Safety door-handle system STS EN 1037 Features The safety door-handle system is suitable for all types of safety guards. Safety switches and solenoid interlocks

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Products POWERFUL TECHNOLOGY

Products POWERFUL TECHNOLOGY Products Rectifiers POWERFUL TECHNOLOGY Device Designation FP 700 HR 00 HR 00 Type Flatpack 700 E8/5 WBrug-GRM0 E60/ WBrug-GRM0 Rated output power 700 W 00 W 00 W Input single-phase single-phase single-phase

More information

Safety Sensor CSS 180 Product Information

Safety Sensor CSS 180 Product Information Safety Sensor CSS 180 Product Information Safety Sensor CSS 180 CSS180CSS 180 PDF-M / EN 60947-5-3 EN 954-1 Control Category 4 IEC 61508, suitable for use in SIL 3 applications BG Type-Certification in

More information

FACTORY AUTOMATION. System Accessories for Mounting and Connection

FACTORY AUTOMATION. System Accessories for Mounting and Connection FACTORY AUTOMATION System Accessories for Mounting and Connection Installing sensors simply and economically! Suitably tailored accessories for the fixing and connection of sensors offer the user enormous

More information

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute NRBM circuit breakers are the largest in rated current (A to 50A) among the IDEC circuit breakers series. These small sized, high-effi ciency breakers offer a variety of protection characteristics that

More information

Safety-door Switch. Ordering Information

Safety-door Switch. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Positively Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Special Operation Key prevents mis-operation.

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches D4S-N D4SN For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Slim Safety Door Switches with

More information

3/2-way Solenoid Valve for pneumatics

3/2-way Solenoid Valve for pneumatics 656 3/-way Solenoid Valve for pneumatics Compact design Single and manifold mounting Low power consumption Rocker pilot in DC Type 656 can be combined with... Fast response times Type 506 Type 510/511

More information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Directly Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Conforms to EN (TÜV) standards corresponding

More information

Installation instructions BasicRelay CR / / 2012

Installation instructions BasicRelay CR / / 2012 Installation instructions BasicRelay CR0421 7390825 / 00 07 / 2012 Contents 1 Preliminary note................................................. 4 1.1 Symbols used...............................................

More information

6mm and 14mm Slim Interface Relay

6mm and 14mm Slim Interface Relay 6mm and mm Slim Interface Relay RV8 Series 6mm Width Electromechanical Screw Terminal Solid State Spring Clamp Terminal PRODUCT DESCRIPTION IDEC 6mm and mm interface relays provide a compact solution for

More information

Cable Plug acc. to DIN EN , Form A

Cable Plug acc. to DIN EN , Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards. Safety-Door Switch Compact Safety Switch Saves Space and is Ideal for a Variety of Doors H Conforms to EN (TÜV) standards. (positive opening mechanism isindicatedonthe switch) H Wide standard operating

More information

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12). Low Signal Relay High sensitivity can be driven by digital circuits Low-profile design allows use in 12.70 mm (0.50 in) PC board rack Surge withstand voltage meets FCC Part 68 regulation Units can be mounted

More information

Standard Interlock Safety Switches

Standard Interlock Safety Switches Subminiature Interlock Switches Key features: Only 78 x 30 x 1m Two actuator entrances provide flexibility for installation options Integrated molded cable reduces wiring time IP67 (IEC60529) Direct Opening

More information

Possible to create the highest level safety system

Possible to create the highest level safety system 14 LIGHT CURTAIS (For PP output type light curtain) Control category 4 Possible to create the highest level safety system Conforming to achine Directive & C Directive Approved Listing Compatible up to

More information

ILE1F661PB1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

ILE1F661PB1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox Characteristics brushless dc motor 24..36 V - CANopen DS301 interface - L = 122 mm - w/o gearbox Product availability : Stock - Normally stocked in distribution facility Price* : 840.00 USD Main Range

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches D4JL D4JL For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. uard Lock Safety-Door Switch Holding

More information

LK Manifold Shunt VS2

LK Manifold Shunt VS2 LK Manifold Shunt VS2 Design LK Manifold Shunt VS2 is a shunt unit with a two way control valve used in systems with a primary pump. The shunt unit is mountable from both the left and right of LK Manifolds.

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor E2Q3 Square Proximity Sensor Terminal housing Integrated short circuit and reverse polarity protection Output function programmable by wiring Active face positioning: Y-axis

More information

DC/DC converters - MINI-PS DC/ 5-15DC/

DC/DC converters - MINI-PS DC/ 5-15DC/ Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid

More information

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking MainswitchSurfacemounting Partno. P1-25/I2/SVB-SW Articleno. 207294 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

Motorized switch-disconnectors OTM 40 to 125 Amperes

Motorized switch-disconnectors OTM 40 to 125 Amperes Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution

More information

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key! 655 Door with Key SERIES Related Information General terms and conditions... F-7 General precautions... P.50 PHOTO PHOTO Conforming to Machine & EMC Directives Recognition Certified MEASURE ITY panasonic.net/id/pidsx/global

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Manual motor starters Overview and benefits

Manual motor starters Overview and benefits Manual motor starters Overview and benefits ABB offers a complete standard motor-protection concept for the world market IEC motor branch protection UL type E/F Motor applications with fuseless protection

More information

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low

More information

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC Power PCB Relay G6D-ASI Reduced board space ideal for high-density mounting (45% smaller than the surface area of G6B). Slim package: measures 6.5 W x 17.5 L x 12.5 H mm Switches loads up to 5 A, 250 VAC/30

More information

Ordering details. BDF 100-➀-➁-➂-ST No. Option Description. ➀ 20 2 NO contacts 11 1 NO contact / 1 NC contact ➁ Selection of the actuator ➂

Ordering details. BDF 100-➀-➁-➂-ST No. Option Description. ➀ 20 2 NO contacts 11 1 NO contact / 1 NC contact ➁ Selection of the actuator ➂ BDF -NH BDF Technical data 3 39 6 4 8 8 M 5 5.5 69.5 Yellow enclosure cover Slim, shock-resistant plastic enclosure Can be fitted onto customary aluminum profile systems Can be installed in the most favorable

More information

Contactors. C110B/80, C110B/120 C110B/200, C110B/300 Single pole DC NO contactors for industrial trucks Catalogue B71.en

Contactors. C110B/80, C110B/120 C110B/200, C110B/300 Single pole DC NO contactors for industrial trucks Catalogue B71.en Contactors C110B/80, C110B/120 C110B/200, C110B/00 Single pole DC NO contactors for industrial trucks Catalogue B71.en 42 C110B Series DC NO contactors for battery voltages C110B Series contactors are

More information

POWER INDUCTOR PIP. AiT Semiconductor Inc. FEATURE APPLICATION ORDERING INFORMATION

POWER INDUCTOR PIP. AiT Semiconductor Inc.   FEATURE APPLICATION ORDERING INFORMATION FEATURE 1. Low profile and Compact Size 2. Low DC resistance 3. Open magnetic circuit construction APPLICATION 3011 2810-R 3015B 10040 1. LCD panels, DC/DC Converters 2. Digital camera, PDA 3. Portable

More information

Limit Switches >> EKU1 series page 635 >> Limit switches for AS-Interface page 641 >> K series page 647 >> GW series page 653 >> O /P series page 659

Limit Switches >> EKU1 series page 635 >> Limit switches for AS-Interface page 641 >> K series page 647 >> GW series page 653 >> O /P series page 659 632 >> EKU1 series page 63 >> Limit switches for AS-Interface page 641 >> K series page 64 >> GW series page 3 >> O /P series page 9 >> Accessories page 661 633 634 Georg Schlegel GmbH & Co. KG - 882 Dürmentingen

More information

Regenerative DC Common Bus Supply

Regenerative DC Common Bus Supply Regenerative DC Common Bus Supply The Regenerative DC Common Bus Supply supplies both motoring and regenerative current to the DC bus of one or more AC drives without the need of rectifier front end in

More information

ILA1F572PB1F0 integrated drive ILA with servo motor V - CANopen - PCB connector

ILA1F572PB1F0 integrated drive ILA with servo motor V - CANopen - PCB connector Characteristics integrated drive ILA with servo motor - 24..36 V - CANopen - PCB connector Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 1860.00 USD Main Range

More information

AZM 161SK 12/12RKED/TU 024

AZM 161SK 12/12RKED/TU 024 10.06.2016 10:17:13h Datasheet AZM 161SK 12/12RKED/TU 024 Solenoid interlock / AZM 161 Thermoplastic enclosure Double insulated Interlock with protection against incorrect locking. 130 mm x 90 mm x 30

More information

SG-B1 SERIES / SG-A1 SERIES

SG-B1 SERIES / SG-A1 SERIES 643 Door with Solenoid Interlock / Door Ultra-slim SG-B1 SERIES / SG-A1 SERIES Related Information General terms and conditions... F-7 General precautions... P.1501 PHOTO PHOTO Conforming to Machine &

More information

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

Installation and Operating Instructions Electric Vibrators HV/VFL Series

Installation and Operating Instructions Electric Vibrators HV/VFL Series Installation and Operating Instructions Electric Vibrators HV/VFL Series Original Instruction Würges Vibrationstechnik GmbH Daimlerstraße 9 D-86356 Neusäß Telephone +49 821 463081 Telefax +49 821 463084

More information

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking MainswitchRearmounting Partno. T0-2-1/V/SVB-SW Articleno. 045992 Front IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1 Power PCB Relay Creepage distance of 8.0 mm (0.31 in) min. between coil and contact Dual-winding latching type available Plug-in and quick-connect terminals available High sensitivity (360 mw) and high

More information

LK Manifold Shunt VS 2-2,5

LK Manifold Shunt VS 2-2,5 LK Manifold Shunt VS 2-2,5 Design LK Manifold Shunt VS (Variable Speed) is a water temperature control pack complete with two way control valve used in systems with a primary pump. The shunt unit is mountable

More information

Strain relief devices

Strain relief devices For optimum placement with dynamic use of cables Trademarks are legally protected for TSUBAKI KABELSCHLEPP GmbH as a national or international registration in the following countries: tsubaki-kabelschlepp.com/trademarks

More information

Reference Manual. UH28C High Voltage Tester

Reference Manual. UH28C High Voltage Tester Reference Manual UH28C High Voltage Tester Preliminary Remarks : Check if the delivery is complete. Take care about probably small parts (plugs etc.). Check for transportation damage, probably not all

More information

0322, 0324, Pilot Solenoid Valve, Plastic

0322, 0324, Pilot Solenoid Valve, Plastic Pilot Solenoid Valve, Plastic Construction The directly controlled GEMÜ 3/2-way pilot solenoid valve consists of an epoxy encapsulated detachable coil and a plastic body. The electrical connection is made

More information

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics 654 3/-way and x 3/-way Solenoid Valve for pneumatics Compact design Single and manifold mounting Low power consumption Fast response times Space saving ( x 3/-way version) Type 654 can be combined with...

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

Safety rope switch with reset for emergency stop

Safety rope switch with reset for emergency stop Safety rope switch with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+,, FP FD FL FC 22 33 34,, CONDUIT ENTRIES Threaded conduit entries (standard) With

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the : 55 Two-hand control panels SEP System components 460 240 190 30 Standards: IEC/EN 60947-5-5 EN 574 EN 418 cast aluminium, powder-coated Protection class: IP 65 Cable section: max. 1.5 mm 2 U i : 440 V

More information

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name Product data sheet CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION General technical data: product brand name Size of contactor Protection class IP / on the front

More information

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation Motor-protectivecircuit-breaker,3p,Ir=2.5-4A Partno. PKZM01-4 Articleno. 278482 CatalogNo. XTPB004BC1 Deliveryprogramme Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton

More information

Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC

Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC AZM 00,,,,, M0x1, 0 1, AZM 00➀-T-➁➂ 0 1 Solenoid interlock (Solenoid interlock monitoring) Thermoplastic enclosure Sensor technology permits an offset of ± mm between actuator and interlock Intelligent

More information

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector Characteristics integrated drive ILA with servo motor - 24..48 V - DeviceNet - indus connector Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Phase

More information

Technical data. Rated operating current/voltage I e /U e : AC-15: 2 A / 24 VAC DC-13: 1 A / 24 VDC Thermal test current I the : 2.

Technical data. Rated operating current/voltage I e /U e : AC-15: 2 A / 24 VAC DC-13: 1 A / 24 VDC Thermal test current I the : 2. 8 Innovations 2/2 - Control panel BDF 2 BDF 2 5.5 22 29 39 3 4 6- Slim, shock-resistant plastic enclosure Can be fitted onto customary aluminium profile systems Can be installed in the most favourable

More information

THREE-POLE CONTACTORS series HR09-HR13 up to 6 kw

THREE-POLE CONTACTORS series HR09-HR13 up to 6 kw THREE-POLE CONTACTORS series HR09-HR3 up 6 kw USE Series HR contacrs are particularly suitable for controlling mors, heating elements and three-phase and single-phase loads in general. OPERATION AND INSTALLATION

More information

Emergency lighting units EM LED Light Engines

Emergency lighting units EM LED Light Engines EM readyapply SELFTEST W EM readyapply Product description LED emergency module suitable for direct installation in ceilings Complete set with integrated electronics, LED module, heat sink, optics and

More information

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19 1 echnical data echnical data, 1 0 3 1 104 7 90 Interlock with protection against incorrect locking hermoplastic enclosure contacts Manual release, emergency exit or emergency release Long life Double

More information

ct O en n Tr ve Solenoid Indicator (1) TÜV rating AC V, 3A 3 Mounting Examples

ct O en n Tr ve Solenoid Indicator (1) TÜV rating AC V, 3A 3 Mounting Examples Di ct O en n Tr ve m minim m Type Circuit Diagram No. [blank] : NC+NC NO/NO [] : NC+NC NO : NC+NC NC+NC [] : NC NC NC * Type Nos. in [ ] are not supplied as standard. Contact IDEC if required. HSC-KR-G-

More information

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5 2.22 415 range Features Metal enclosure Two switches in one enclosure Problem-free opening of stressed doors by means of bell-crank system Robust design Long life High holding force 3,500 N Adjustable

More information

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox Characteristics brushless dc motor 24..36 V - CANopen DS301 interface - L = 122 mm - w/o gearbox Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Network

More information

Thermal overload relay TF140DU and TF140DU-V1000

Thermal overload relay TF140DU and TF140DU-V1000 Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Single foot switches PX and PA series

Single foot switches PX and PA series A Single foot switches PX and PA series Selection diagram CARRYING ROD See page /10 ADDITIONAL METAL PROTECTION OPEN PROTECTIONS CLOSED PROTECTIONS PA PA 2 CONTACT BLOCKS COMBINATIONS 01 02 1NO+1NC snap

More information

Operating conditions. Surface roughness R a R max

Operating conditions. Surface roughness R a R max Merkel U-Ring NI 300 Merkel U-Ring NI 300 Asymmetrical sealing lips PUR profile ring Sealing edge Material Material Code Hardness Polyurethane 94 AU 925 94 Shore A Operating conditions Material 94 AU 925

More information

Thermal overload relay TF65 and TF96

Thermal overload relay TF65 and TF96 Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and

More information

Lexium integrated drives

Lexium integrated drives Description ILp for DeviceNet, EtherCAT, Modbus TCP, ILE with brushless DC motor Description ILE comprise control electronics with a fieldbus interface for DeviceNet, EtherCAT, Modbus TCP or and a brushless

More information

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from Omron STI Application Support Thank you for your interest in Omron STI products. Please contact Omron STI with your application questions. Support Engineers are available at our USA headquarters from 4:00

More information

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5 2.19 AZM 19 range 13 44 32 2,3 3 1 Features Voltage variants Approvals Thermoplastic enclosure Manual / Emergency release Long life Actuation on de-energisation or energisation Slim design, particularly

More information

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable PCB Relay Surface Mounting DPDT Relay Long terminals for ideal for soldering and mounting reliability. Space-saving inside-l terminal. High dielectric strength between coil and contacts (2,000 VAC), and

More information

Inductive Proximity Sensor

Inductive Proximity Sensor ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-110020(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Inductive Proximity Sensor E2Q3 Square

More information

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g. Tactile Switch BW Tactile Switch with Sealed Construction for Automatic Soldering Sealed construction conforming to IP67 (IEC-6059) provides high reliability in locations exposed to dust or water. Available

More information

Prewired position switches FF series

Prewired position switches FF series 2 Prewired position switches FF series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45 46

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection

More information

RUC industrial relays of small dimensions

RUC industrial relays of small dimensions RUC 135 with adaptor (V) Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 01 A1 08 14 01-7 0 A 05 A5 external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket 0 1 5 34 50 33

More information

FACTORY AUTOMATION ALWAYS THE RIGHT CONNECTION CORDSETS FROM PEPPERL+FUCHS

FACTORY AUTOMATION ALWAYS THE RIGHT CONNECTION CORDSETS FROM PEPPERL+FUCHS FACTORY AUTOMATION ALWAYS THE RIGHT CONNECTION CORDSETS FROM PEPPERL+FUCHS CORDSET PRODUCTION CENTER Our production site in Veszprem, Hungary is the center of our injection molding operations. Over 200

More information

Electronic overload relays EF205 and EF370

Electronic overload relays EF205 and EF370 Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications Safety Limit Switch Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications H Snap-action contact for accurate switching with safe operation via direct drive positive

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information