SYSTEM COMPONENTS DIALOCK HOTEL

Size: px
Start display at page:

Download "SYSTEM COMPONENTS DIALOCK HOTEL"

Transcription

1 SYSTEM COMPONENTS DIALOCK HOTEL

2 DT 700 Door Terminal, with Thumbturn Product overview DT 700 Door Terminal, with ThumbturnProduct overviewplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Ordering product components Standard Optional B D E G F! DK 10.2 DK 10.8 DK DK DK DK DK " DT 700 door terminal set Mortise lock* Profile cylinder for emergency opening Mounting material Maintenance tools and batteries Angled striking plate for mortise locks with 20 mm forend Accessories for processing and installation Programming and user keys! For guest room doors made from wood (with "Do not disturb" function) " For guest room doors made from metal (with "Do not disturb" function) DK A flanged striking plate is supplied for mortise locks with 24 mm forend. No striking plate is supplied for mortise locks with 20 mm forend. Please order separately. Sample order For interior hotel guest room door, made from wood, flush 42 mm, DIN right, backset 55 mm, battery-operated door terminal, comfort function outwards opening doors Door terminal set DT 700 door terminal set, with thumbturn, stainless steel matt B Mortise lock with flanged striking plate For doors with standard requirements, stainless steel coloured D Profile cylinder for mechanical emergency opening DK 10.3 DK Single cylinder, keyed different DK E Mounting material Mounting set 1 DK F Accessories for processing and installation DK G Maintenance tool Alkaline-manganese battery 1.5 V AA DK Programming and user keys DK DK 10.1

3 DT 700 Door Terminal, with Thumbturn For interior doors (hotel guest room doors) Electronic Access Control SystemsDT Door Terminal, with ThumbturnFor interior doors (hotel guest room doors)planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. DT 700 Door terminal set ID 1844 DK 10.2 Door terminal set for interior guest room doors, approved for fire resistant and smoke control doors, satin stainless steel or polished brass coloured, with fixed lever handle aperture parts, door backplate internal module with battery. Functionality Battery-operated, intelligent door terminal, touchless activation with Dialock key (passive transponder) Red/white LEDs/Piezo sound generator for indication of locking and unlocking Door backplate internal module with thumbturn with which "Do not disturb" can be indicated on the exterior module by a flashing signal (thumbturn = DND = Do not disturb function). Mechanical locking takes place by turning the thumbturn, pushing forward the deadbolt of the mortice lock. The door can be opened without a key at any time from the inside by operating the lever handle. Several keys per room and up to 20 keys per door terminal possible Mechanical emergency opening possible With real-time clock for audit trail of all locking processes, openings of the housing, emergency openings and battery removals (memory for up to 1,000 audit trail entries, for up to 1,000 user keys) Tamper protection on internal module blocks the door terminal in case of removal of the internal backplate. Access from the outside is blocked for user keys with activated tamper protection. The tamper protection can be activated (optional). For service personnel: Indication when battery change is required Advantages Easy mounting Easy battery change Drilling dimensions in accordance with DIN additional drill hole for DND; no cut-outs required in the door leaf Installation with standard rose fixing points Technical data Degree of protection IP20 Ambient temperature (operation) 0 C to +55 C Relative humidity Life time of battery Backset Spindle Distance Door thickness Standard 0 95 % (not condensed) Approx. 2 years, generally 10 locking cycles per day 55 or 65 mm 9 mm 72 mm mm Tested for fire resistance in accordance with EN 1634, T90 Tested to EN (mortice lock), EN 1906 (terminal), EN 179 (with suitable and appropriate lever handle design) Electrostatic discharge (ESD) High level security, tested to 20,000 V (standard 8,000 V) Voltage supply Memory Notes for operation and installation Alkaline manganese battery 1.5 V AA (4 pieces) For up to 1,000 audit trail entries, for up to 1,000 keys Planning by Dialock specialist is required. DT 700 door terminal modules on fire resistant and smoke control doors must be installed by Dialock specialists after approval by the door manufacturer. If the terminal is installed without this permission, the Fire and Smoke Control Certificate for the door will be invalidated. Can only be used in combination with the DIN mortice lock for DT 700. The comfort function is determined with the mortice lock. Mechanical emergency opening The DT 700 door terminal set must always be equipped with a single profile cylinder or short profile cylinder for mechanical emergency opening. When using the mechanical emergency opening, please note the information sheet for determining the single profile cylinder length or short profile cylinder length. The batteries in the door backplate internal module are secured with a special screw in the cover. This is meant to avoid unauthorised removal of the batteries. To insert the batteries into the internal module, a special bit is required. Please order separately.

4 DT 700 Door Terminal, with Thumbturn For interior doors (hotel guest room doors) Determine lever handle and opening direction Electronic Access Control SystemsDT 700 Door Terminal, with ThumbturnFor interior doors (hotel guest room doors)planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice.! Internal module " Exterior module (access control) The opening direction inwards or outwards must be selected Exterior module with with the mortice lock. lever handle pointing to the left, outwards opening, DIN left mortice lock $ Exterior module with % Exterior module with lever handle pointing to the lever handle pointing to left, inwards opening, the right, inwards opening, DIN right mortice lock DIN left mortice lock & Exterior module with lever handle pointing to the right, outwards opening, DIN right mortice lock DT 700 offline 1 exterior module with fixed lever handle aperture part 1 internal module with thumbturn and fixed lever handle aperture part Stainless steel Satin Polished brass coloured Dim. E, door thickness External length C, relevant for profile cylinder and mounting set selection Internal length D, relevant for profile cylinder and mounting set selection Dim. A, external length of profile cylinder Dim. B, internal length of profile cylinder, must not exceed dim. B1 2 square spindles for DND thumbturn are included in the mounting set. The short square spindle must be used for outwards opening doors, the longer square spindle for inwards opening doors. A detailed description of the installation of the square spindles can be found in the installation instructions. The following components must also be ordered for a fully operational unit: 1 Mortice lock for DT 700 / DT Profile cylinder for mechanical emergency opening 4 Batteries AA 1 Angled striking plate, only for mortice locks with 20 mm forend Mounting tool special bit or SW3 screwdriver for screw with security pin Mounting set (threaded screws and square spindle) If an escape route door in compliance with EN 179 is required, only the use of U-shaped lever handle aperture parts is permitted. Ordering product components DK 10.1 Special bit DK DK ID 1844

5 DT 710 Door Terminal, with Thumbturn Product overview DT 710 Door Terminal, with ThumbturnProduct overviewplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Ordering product components Standard Optional B D E G F! DK 10.5 DK 10.8 DK DK 10.7 DK DK DK DK " DT 710 door terminal set Mortise lock* Profile cylinder for emergency opening Escutcheon foil Mounting material Maintenance tools and batteries Angled striking plate for mortise locks with 20 mm forend Accessories for processing and installation Programming and user keys! For guest room doors made from wood (with "Do not disturb" function) " For guest room doors made from metal (with "Do not disturb" function) DK A flanged striking plate is supplied for mortise locks with 24 mm forend. No striking plate is supplied for mortise locks with 20 mm forend. Please order separately. Sample order For interior hotel guest room door, made from wood, flush 42 mm, DIN right, backset 55 mm, battery-operated door terminal, comfort function outwards opening doors Door terminal set DT 710 door terminal set, with thumbturn, stainless steel matt B Mortise lock with flanged striking plate For doors with standard requirements, stainless steel coloured D Profile cylinder for mechanical emergency opening DK 10.5 DK Single cylinder, keyed different DK E Mounting material Mounting set 1 DK F Accessories for processing and installation DK G Maintenance tool Alkaline-manganese battery 1.5 V AA DK Programming and user keys DK DK 10.4

6 DT 710 Door Terminal, with Thumbturn For interior doors (hotel guest room doors) Electronic Access Control SystemsDT Door Terminal, with ThumbturnFor interior doors (hotel guest room doors)planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. DT 710 Door terminal module Door terminal set for interior guest room doors, approved for fire resistant and smoke control doors, satin stainless steel or polished brass coloured, with fixed lever handle aperture parts, door backplate internal module with battery. Functionality Battery-operated, intelligent door terminal, touchless activation with Dialock key (passive transponder) Red/white LEDs/Piezo sound generator for indication of locking and unlocking Door backplate internal module with thumbturn with which "Do not disturb" can be indicated on the exterior module by a flashing signal (thumbturn = DND = Do not disturb function). Mechanical locking takes place by turning the thumbturn, pushing forward the deadbolt of the mortice lock. The door can be opened without a key at any time from the inside by operating the lever handle. Several keys per room and up to 20 keys per door terminal possible Mechanical emergency opening possible With real-time clock for audit trail of all locking processes, openings of the housing, emergency openings and battery removals (memory for up to 1,000 audit trail entries, for up to 1,000 user keys) Tamper protection on internal module blocks the door terminal in case of removal of the internal backplate. Access from the outside is blocked for user keys with activated tamper protection. The tamper protection can be activated (optional). For service personnel: Indication when battery change is required Advantages Easy mounting Easy battery change Drilling dimensions in accordance with DIN additional drill hole for DND; no cut-outs required in the door leaf Installation with standard rose fixing points Technical data Degree of protection IP20 Ambient temperature (operation) 0 C to +55 C Relative humidity Life time of battery Backset Spindle Distance Door thickness 0 95 % (not condensed) Approx. 2 years, generally 10 locking cycles per day 55 or 65 mm 9 mm 72 mm mm Standard Tested for fire resistance in accordance with EN 1634, T90, tested to EN (mortice lock), EN 1906 (terminal), EN 179 (with suitable and appropriate lever handle design) Electrostatic discharge (ESD) High level security, tested to 20,000 V (standard 8,000 V) Voltage supply Memory Notes for operation and installation Alkaline manganese battery 1.5 V AA (4 pieces) For up to 1,000 audit trail entries, for up to 1,000 keys Planning by Dialock specialist is required. DT 710 door terminal modules on fire resistant and smoke control doors must be installed by Dialock specialists after approval by the door manufacturer. If the terminal is installed without this permission, the Fire and Smoke Control Certificate for the door will be invalidated. Can only be used in combination with the DIN mortice lock for DT 710. The comfort function is determined with the mortise lock. Mechanical emergency opening The DT 710 door terminal set must always be equipped with a single profile cylinder or short profile cylinder for mechanical emergency opening. When using the mechanical emergency opening, please note the information sheet for determining the single profile cylinder length or short profile cylinder length. The batteries in the door backplate internal module are secured with a special screw in the cover. This is meant to avoid unauthorised removal of the batteries. To insert the batteries into the internal module, a special bit is required. Please order separately. DK ID 1844

7 DT 710 Door Terminal, with Thumbturn For interior doors (hotel guest room doors) Electronic Access Control SystemsDT 710 Door Terminal, with ThumbturnFor interior doors (hotel guest room doors)planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Determine lever handle and opening direction! Internal module " Exterior module (access control) The opening direction inwards or outwards must be selected Exterior module with with the mortice lock. lever handle pointing to the left, outwards opening, DIN left mortice lock $ Exterior module with lever handle pointing to the left, inwards opening, DIN right mortice lock % Exterior module with & Exterior module with lever handle pointing to lever handle pointing to the right, inwards opening, the right, outwards opening, DIN left mortice lock DIN right mortice lock DT 710 offline 1 exterior module 1 rose with fixed lever handle aperture part 1 internal module with thumbturn and fixed lever handle aperture part 1 escutcheon foil, grey, blank Stainless steel Satin Polished brass coloured ID 1844 DK 10.6 Dim. E, door thickness External length C, relevant for profile cylinder and mounting set selection Internal length D, relevant for profile cylinder and mounting set selection Dim. A, external length of profile cylinder Dim. B, internal length of profile cylinder, must not exceed dim. B1 2 square spindles for DND thumbturn are included in the mounting set. The short square spindle must be used for outwards opening doors, the longer square spindle for inwards opening doors. A detailed description of the installation of the square spindles can be found in the installation instructions. The following components must also be ordered for a fully operational unit: 1 Mortice lock for DT 700 / DT Profile cylinder for mechanical emergency opening 4 Batteries AA 1 Angled striking plate, only for mortice locks with 20 mm forend Mounting tool special bit or SW3 screwdriver for screw with security pin Mounting set (threaded screws and square spindle) If an escape route door in compliance with EN 179 is required, only the use of U-shaped lever handle aperture parts is permitted. Ordering product components DK 10.4 Special bit DK 10.14

8 DT 710 Door Terminal E Supplementary products Electronic locking systemsdt 710 Door TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Escutcheon foil for reader module Area of application: Cover foil for sticking onto DT 710 reader module Material: Plastic Colour: Grey or white Without aperture (blank) With PC aperture (profile cylinder) Apertures Colour Blank Grey White PC Grey White Customised design of the escutcheon foil is available on request (from an order quantity of 50 pieces). Electronic locking systemsdt 710 Door terminald Supplementary products / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Spacer plate for reader module Area of application: Dim. C of the profile cylinder may be too long for thin doors. In this case, a spacer plate can be used to compensate for deviations (max. 3 mm) Thickness: 3 mm Compensation with spacer plate Reader module with spacer plate 3 mm A spacer plate 3 mm can be used to compensate for thin doors (optional). The max. possible cylinder dimension (dim. A) is then increased by 3 mm. The min. cylinder dimension (dim. A) remains the same when using the blank escutcheon foil, when using the PC escutcheon foil it is increased by 3 mm. Dim B. max. = dim. D 2 mm Comfort function Please note different dim. C with comfort function inwards and outwards opening doors. Technical data Dim. A mm DT 710 reader module with blank escutcheon foil Dim. B mm Dim. C mm Comfort function inwards opening doors Short double cylinder (e.g ) Dim. C mm Single cylinder (e.g ) Comfort function outwards opening doors Material Finish Stainless steel Matt Brass coloured polished DK 10.7

9 DT 700 / DT 710 Door Terminal Electronic Access Control SystemsDT 700 / DT 710 Door Terminal / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Individual components: DT 700 and DT 710 door terminal set Material: Finish: Version: Stainless steel Matt or brass coloured polished Identical to the DT 700 and DT 710 door terminal modules, but divided into internal and external module DT 700 and DT 710 Offline 1 internal module with thumbturn and fixed lever handle aperture part Model series DT 700 and DT 710 Stainless steel matt brass coloured polished external module with fixed lever handle aperture part DT external module with fixed lever handle aperture part DT DK 10.7 A

10 DK 10.7 B

11 DT 700 / DT 710 Door Terminal B Mortice locks Electronic Access Control SystemsDT / DT 710 Door TerminalB Mortice locksplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. DT 700 and DT 710 Mortice lock Flanged striking plate DIN L (only with forend plate 24 mm) Flanged striking plate DIN R (only with forend plate 24 mm) Area of application: Version: Type of locking: Deadbolt: Forend: Lever follower: Distance: Mounting: Material: Finish: For rebated doors (forend 20 mm) or flush doors (forend 24 mm), suitable for fire resistant and smoke control doors Electrically connectable mortice lock with feedback (sensors for latchbolt/deadbolt position), comfort function and emergency opening function, deadlocking latchbolt and deadbolt, connection cable for electrical coupling and sensors for connection with DT 700 or DT 710 interior module Prepared for profile cylinder 1-turn Round 9 mm 72 mm DIN L and DIN R Forend: Stainless steel, latchbolt and lock case: Steel, lever follower: Malleable cast Satin, lock case: Black ID1869 DK 10.8 Installation Door routing dimensions Observe the lock pocket dimensions. Dimension! in drawing is greater than with normal mortice locks due to the cable outlet. Door drilling dimensions *13 mm drill hole on one side for DND spindle, only on the inside. Determination of comfort function A door can be inwards or outwards opening irrespective of the mounting. The side with comfort function is marked with a label. Emergency opening function Emergency opening function is monitored (feedback). Opening of door from outside: By turning the key in the profile cylinder (key action), the latchbolt and deadbolt are retracted. Opening of door from inside: By activating the lever handle, the latchbolt and deadbolt are retracted.

12 DT 700 / DT 710 Door Terminal B Mortice locks Electronic Access Control SystemsDT 700 / DT 710 Door TerminalB Mortice locksplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. 1 Mortice lock 1 Forend screw 70 mm (not suitable for backset 55 mm; screw must be installed) 1 Forend round or square, satin stainless steel or polished brass coloured, 2 fixing screws 1 Flanged striking plate, satin stainless steel or polished brass coloured (only supplied with forend width 24 mm) Forend width mm Backset A 55 mm, forend round Mounting Striking plate is not supplied for mortice locks with 20 mm forend. Please order separately. Stainless steel Satin Polished brass coloured 20 DIN L, comfort function outwards opening doors Backset A 65 mm, forend round DIN L, comfort function inwards opening doors DIN R, comfort function outwards opening doors DIN R, comfort function inwards opening doors DIN L, comfort function outwards opening doors DIN L, comfort function inwards opening doors DIN R, comfort function outwards opening doors DIN R, comfort function inwards opening doors DIN L, comfort function outwards opening doors Backset A 65 mm, forend square DIN L, comfort function inwards opening doors DIN R, comfort function outwards opening doors DIN R, comfort function inwards opening doors DIN L, comfort function outwards opening doors DIN L, comfort function inwards opening doors DIN R, comfort function outwards opening doors DIN R, comfort function inwards opening doors DK ID1837

13 DT 700 / DT 710 Door Terminal B Mortice lock accessories DT 700 / DT 710 Door TerminalB Mortice lock accessoriesplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Flanged striking plate Dimensional data not binding. We reserve the right to alter specifications without notice. Area of application: Version: For wooden frames, for flush doors Straight flange Material Finish/colour DIN left DIN right Brass Polished with protective lacquer Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Area of application: For wooden frames, for flush doors, Version: Curved flange Material Finish/colour DIN left DIN right Stainless steel Satin Door LocksFor DT door terminalsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Recessed striking plate ID 1857 DK Area of application: Version: Mounting: For wooden frames, for rebated doors For 2-turn mortice locks, with plastic strike box For DIN left and DIN right hand use Material Finish/colour Stainless steel Satin, light grey plastic strike box

14 DT 700 / DT 710 Door Terminal B Mortice lock accessories DT 700 / DT 710 Door TerminalB Mortice lock accessoriesplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Angled striking plate Area of application: Version: Mounting: For wooden frames, for rebated doors Round or square For DIN left and DIN right hand use Round fold Square fold Version Material Finish/colour Round Stainless steel Satin Square Brass Polished with protective lacquer Round Steel White lacquered Nickel silver colour lacquered Brass coloured, hammer effect enamelled lacquered Striking PlatesStriking PlatesFor rebated doorsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Angled striking plate Area of application: Version: For wooden frames, for rebated doors, for mortice locks with high deadbolt Round or square Version Material Finish DIN left DIN right Round Stainless steel Square Brass Polished with protective lacquer Satin Round fold Square fold ID 1833 DK A

15 ID 1833 DK B

16 DT 700 / DT 710 Door Terminal D Profile cylinder for emergency opening Electronic Access Control SystemsDT 700 / DT 710 Door TerminalD Profile for emergency openingplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Profile cylinders Type of locking: Material: Finish: Short double cylinder: Keyed to differ or keyed alike, single cylinder: S1 keyed alike Cylinder housing: Brass, key: Steel Cylinder housing and key: Nickel plated Note A detailed product description of the short double cylinder and other keyed alike and keyed to differ key changes can be found on the following page. Short double cylinder Startec single cylinder 1 Short double cylinder or single cylinder 3 Keys 1 Fixing screw Dim. A mm Dim. B mm Short double cylinder DT 700 reader module Dim. B max. = dim. D 2 mm Comfort function Please note different dim. C with comfort function inwards and outwards opening doors. DT 710 reader module with blank escutcheon foil DT 710 reader module with PC escutcheon foil Dim. C mm Dim. C mm Dim. C mm Dim. C mm Dim. C mm Dim. C mm Comfort function inwards opening doors Comfort function outwards opening doors Comfort function inwards opening doors Comfort function outwards opening doors Comfort function inwards opening doors Comfort function outwards opening doors Single cylinder Type of locking Short double cylinder Dim. A mm Dim. B mm Keyed to differ Keyed alike Startec single cylinder S1 keyed alike DK ID 1855

17 DT 700 / DT 710 Door Terminal D Profile cylinder for emergency opening Electronic locking systemsdt 700 / DT 710 Door TerminalD Profile cylinder for emergency openingplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Short double cylinder Keyed alike without key 1 Short double cylinder 1 Fixing screw Short double cylinder without key Key change Please order suitable keys for cylinder separately. Key 1 Short key Closure: Locking system: Material: Finish: Length L: Dim. A: Dim. B: Note No secured locking, locking system and extension of double cylinder possible. The keys are shorter to suit the short design of the double cylinder. Therefore the keys are not suitable for other profile cylinders. The short double cylinder is not suitable for fire resistant or smoke control doors! Suitable are all single or double cylinders from 27.5 mm in this catalogue. Keyed different 1 Short double cylinder 3 Short keys 1 Fixing screw Keyed alike with key 1 Short double cylinder 3 Short keys 1 Fixing screw Keyed different or keyed alike With 3 pin tumblers Cylinder housing: Brass Cylinder housing and key: Nickel plated 43.4 mm 21.7 mm 21.7 mm Short double cylinder with keys Short double cylinder with keys Key change Key DK 10.12

18 DT 700 / DT 710 Door Terminal D Supplementary products DT 700 / DT 710 Door TerminalD Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Mounting set > Functionality: For connecting the exterior/interior module and thumbturn with the mortice lock > Material: Steel, threaded screws: Stainless steel Note Mounting sets 1, 2, 4, 6, 7, 9 and 11 are supplied with 2 DND spindles. The installation instructions explain which spindle has to be used. Dim. E mm 4 cylinder screws M4, SW 3 hexagon socket, with security pin 2 spindles 9 mm 1 (2) DND spindle(s) 5 mm Dim. C mm Dim. D mm Stainless steel Satin Polished brass coloured Mounting set 1 Door thickness Mounting set 2 Door thickness Mounting set Mounting set Mounting set 5 Door thickness Mounting set Mounting set Mounting set Mounting set 9 Door thickness Mounting set Mounting set Mounting set 10 Door thickness Mounting set Profile cylinders DK DK D1883

19 DT 700 / DT 710 Door Terminal F Processing and installation Bits and accessoriesdt 700 / DT 710 Door TerminalF Processing and installation / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. box Electronic Access Control SystemsDT 700 / DT 710 Door TerminalF Processing and installation / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Drilling jig > Area of application: For mounting the DT 700 / DT 710 door terminal, for SW3 hex socket head screws with security pin > Length: 25 mm > Drive: 1/4" 1 universal magnetic holder 6 bits for SW3 hex socket head screws with drill hole for security pin 4 PH2 bits Packing: 1 piece Bit box ID 1877 DK DT 700 / DT 710 Door TerminalF Processing and installation / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Screwdriver For SW3 hex socket head screws, with security pin Packing: 1 piece Electronic Access Control SystemsG Service and maintenance / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Battery AA Note We recommend using these batteries only in order to guarantee smooth operation of the Dialock terminals. 4 pieces required for one door terminal set. Screwdriver > Operating temperature: Alkaline-manganese battery 1.5 V AA (standard) 18 to +55 C with alkaline-manganese, 40 to +60 C with lithium Packing 10 or 120 pieces Lithium battery 1.5 V AA 2 or 10 pieces > Area of application: For work preparation for mounting the DT 700 / DT 710 door terminals on door Installation Information on how to use the drilling jig can be found in the installation instructions for the DT 700 / DT 710. The installation instructions can be found in our online shop "Easy link". 2 steel plates (inside and outside) Centring pins with stop sleeves 1 drill bit 13 mm 1 drill bit 8 mm 1 router bit Packing: 1 piece Electronic Access Control SystemsG Service and maintenance / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Cover plate For covering the edge of the drillings for TSE door terminals Note Also suitable for the use on fire resistant and smoke control doors. 2 cover plates are required for 1 door. Packing: 1 piece Minimum order quantity for cover plates is 20 pieces. Drilling jig TSE door terminal > Area of application: For covering the installation holes (with possible colour deviations and pressure marks) when replacing TSE door terminal with DT 700/710 door terminal > Material: Stainless steel > Finish: Satin > Dim. (L x W): 310 x 72 mm Cover plate DK 2017, HDE-en, 01/17; Dimensional data not binding. We reserve the right to alter specifications without notice.

20 Sales Support Electronic Access Control SystemsSales SupportPlanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Selling aids for door hardware solutions in Dialock projects Selling aids for customer Completely functional mock-ups (mechanics and programming) Version: Mock-up of DT door terminals, additionally with programming cards and user keys for operating the mock-ups, as well as keys for profile cylinder and tools for battery change, supplied in Systainer or bag (depending on the mock-up type) Technology DT 700/DT 710 BLE door terminal mock-up Programming cards and user keys 3 keys for profile cylinder With Bluetooth Low Energy (BLE), only for use with the Hotel Bird smartphone key app. Mifare Classic DK ID A

21 ID 1803 DK B

22 Häfele Dialock WT 200 and WT 220 Wall Terminal Product overview Häfele Dialock WT 200 and WT 220 Wall TerminalProduct overviewplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Ordering product components Standard Optional E E! Page DK DK DK DK 6.1 DK DK DK " WRU 200 or WRU 220 wall reader WTC 200 controller Power supply Electric strike, reed sensor, multiple-locking device, motor mortice locks ESS 100 energy control terminal Automatic circuit breakers and relays Installation accessories Programming and user keys! For external doors made from wood, metal, glass or narrow frames EN 179 Doors with requirements on fire resistance/smoke control, EN 179 or EN 1125 are possible if the door structure also meets the respective requirements. " For interior doors made from wood, metal, glass or narrow frames EN 1125 EN 179 Doors with requirements on fire resistance/smoke control, EN 179 or EN 1125 are possible if the door structure also meets the respective requirements. DK EN 1125 Sample order Entrance door, projects, mains-operated wall terminal with Dialock design WT 200 wall terminal set Set consists of: WRU 200 wall reader WTC 200 controller E Power supply DK DC power supply unit, regulated DK E Lock Secury Automatic-A opener multiple locking device x lock case Angled security striking plate Optional E Automatic circuit breakers and relays DK E Installation accessories DK Automatic circuit breakers, relays and installation accessories as required Energy control terminal for hotels, additional wall reader on opposite side as required Programming and user keys DK ID 1872 DK 10.15

23 Dialock Wall Terminal For indoor or outdoor use Electronic Access Control SystemsDialock Wall TerminalFor indoor or outdoor use / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. WT 200 Wall terminal set Area of application: Use as authorisation and/or wall unit, block lock function, for controlling any type of door, gates, car park barriers, furniture and furnishings, lights, alarm systems, video surveillance... 1 WRU 200 wall reader 1 WTC 200 controller Please refer to the descriptions of the WRU 200 wall reader and WTC 200 controller for more detailed information about the individual components of the WT 200 set. Please order supplementary and optional components, e.g. energy control terminal, power supply and lock, separately. WRU 200 wall reader DK WTC 200 controller DK Electronic Access Control SystemsDialock Wall TerminalFor indoor or outdoor use / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. WRU 200 Wall reader Space requirement flush mounted box WRU 200 wall reader (writer and reader unit) plastic, anthracite/silver coloured, for combination with WTC 200 controller Functionality Mains-operated wall terminal, touch-free activation with Dialock key Red/green LEDs for indication of locking and unlocking For service personnel: Indication of operating status (e.g. offline) Notes for operation and installation Please order supplementary and optional components, e.g. energy control terminal, power supply and lock, separately. Technical data Degree of protection Ambient temperature (operation) IP65 Voltage supply V DC ±15% Current consumption RFID Indication Interface Relative humidity Connection Dimensions 25 C to +70 C with temperature monitoring 0.8 W f = MHz 1 x LED red, 1 x LED green 1 x RS-485, automatic baud rate detection % (not condensed) Terminals for e.g. J-Y(St)Y2x2x0.8, max. 100 m Width 81 mm, height 81 mm, depth 13 mm (surface mounted) 35 mm (flush mounted) Connection between WRU 200 wall reader and WTC 200 controller with four core installation cable in compliance with VDE 0815: Type J-Y(St)Y 2 x 2 x 0.8 mm (twisted pair, shielded), max. length 100 m (please contact Dialock specialist for other lengths). Installation of wall reader in flush mounted box with 2 device fastening screws (distance 60 mm in compliance with DIN). Make sure the fastening points on the flush mounted box are horizontal. Minimum distance between 2 wall readers 250 mm. The installation of the wall reader in metal surroundings must be planned. 1 WRU 200 wall reader Ordering product components DK DK 10.16

24 Häfele Dialock WT 220 Wall Terminal For indoor or outdoor use Electronic Access Control SystemsHäfele WT 220 Wall TerminalFor indoor or outdoor useplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Dialock WT 220 Wall terminal set Area of application: Use as authorisation writer, block lock function, for controlling any type of door, gates, car park barriers, furniture and furnishings, lights, alarm systems, video surveillance... Recommendation: WRU 220 wall reader with Gira 55 system frame, glossy pure white Häfele Dialock WRU 220 wall reader WTC 200 controller 1 WRU 220 wall reader (without frame) 1 WTC 200 controller More information on the WT 220 wall terminal set can be found in the descriptions of the individual components (WRU 220 wall reader, WTC 200 controller). The frame (Gira or Siedle) for the WRU 220 wall reader is not supplied, please order separately as well as supplementing and optional components such as energy control terminal, voltage supply and lock. WTC 200 controller DK Häfele Dialock WRU 220 Wall reader WRU 220 wall reader (writer and reader unit) for combination with WTC 200 controller Functionality Mains-operated wall terminal, touchless activation with Dialock key Red/green LEDs for indication of locking and unlocking For service personnel: Indication of operating status (e.g. offline) The frame for customised design is not supplied, please order separately. Suitable frame (Gira or Siedle) Gira: 55 system, S-Color system and TX_44 system Siedle: BM blind module (must be provided on site) Please order supplementary and optional components, e.g. energy control terminal, power supply and lock, separately. Notes on operation and installation Technical data Degree of protection Ambient temperature (operation) Voltage supply V DC ±10% Current consumption RFID Indication Interface Relative humidity Connection Dimensions IP00 wall reader without frame IP20 wall reader with Gira frame IP44 wall reader with Gira TX_44 system frame IP 54 with Siedle blind module 25 C to +65 C with temperature monitoring 0.8 W f = MHz 1 x LED red, 1 x LED green 1 x RS-485, automatic baud rate detection % (not condensed) Terminals for e.g. J-Y(St)Y2x2x0.8, max. 100 m Width 71 mm, height 71 mm, depth 20 mm Connection between WRU 220 wall reader and WTC 200 controller with four core installation cable in compliance with VDE 0815: Type J-Y(St)Y 2 x 2 x 0.8 mm (twisted pair, shielded), max. length 100 m (please contact Dialock specialist for other lengths). Installation of wall reader in flush-mount socket with 2 device fastening screws (distance 60 mm in compliance with DIN). Make sure the fastening points on the flush-mount socket are horizontal. Minimum distance between 2 wall readers 250 mm. The installation of the wall reader in metal surroundings must be planned. 1 WRU 220 wall reader (without frame), including configuration transponder No. 20 (for addressing the wall reader) Ordering product components DK Gira frames DK A DK ID A

25 Häfele Dialock Wall Terminal For indoor or outdoor use Electronic locking systemshäfele Dialock Wall TerminalFor indoor or outdoor useplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. WTC 200 Controller ID 1872 DK WTC 200 Controller made from plastic, anthracite/silver coloured, for combination with WRU 200 or WR 220 wall reader Functionality Mains-operated, intelligent controller for online operation Use as authorisation writer and/or wall terminal, block lock function Selective control of up to 2 electrical devices Plug & Play installation, configures all system parameters on an SD card using the software Authorisation writer for updating authorisations at offline terminals Indication of operating status in the Dialock 2.0 software Just-in-time modifications of authorisations With integrated real-time clock for programming time restricted locking authorisations (setting of time zones) With audit trail of all processes With 4 input ports for analysing input signals (e.g. reed contact for door monitoring). In combination with electric strike or mortice lock with feedback contact, this allows visual overall monitoring the status of the locking system. Change configurations and update firmware online with the Dialock 2.0 software Options (please order separately) WTX 200 I/O expansion module with 3 relay output ports and 4 analogue input ports 8-way relay module with 8 relay output ports and 1 analogue input port Notes for operation and installation Please order supplementary and optional components, e.g. energy control terminal, power supply and lock, separately. Technical data Degree of protection Ambient temperature (operation) IP30 (sheet steel housing), installation on hat rail depends on housing 0 C to +50 C Voltage supply V DC ±15% Current consumption CPU Interfaces Slot Storage media Relative humidity 1.5 W 32 bit 168 MHz Cortex M4 1 x Ethernet 10/100 Mbit/s 3 x RS-485 interfaces with power supply 2 x relay output ports (changeover contact 30 V/2 A) 4 x analogue input ports 1 x USB interface For WTX 200 I/O expansion 1 x micro SD card (with optional 128 bit SSL encryption) 512 kb flash 128 KB SRAM % (not condensed) Connection Screw terminals 2.5 mm 2 Installation on hat rail Width 165 mm, height 130 mm, depth 65 mm in sheet steel housing Width 300 mm, height 300 mm, depth 132 mm Connection between WRU 200/WRU 220 and WTC 200 controller with four core installation cable in compliance with VDE 0815: Type J-Y(St)Y 2 x 2 x 0.8 mm (twisted pair, shielded), max. length 100 m (please contact Dialock specialist for other lengths). 1 WTC 200 controller WRU 200 wall reader DK WRU 220 wall reader DK A

26 Häfele Dialock Wall Terminal For indoor or outdoor use Electronic Access Control SystemsHäfele Dialock Wall TerminalFor indoor or outdoor use / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. WTX 200 I/O Expansion For expansion of WTC 200 controller Functionality > Connection of up to 4 monitoring contacts > Connection of up to 2 electric strikes (relays) > Combined connection of monitoring contacts and electric strikes to up to 6 pins > Up to 3 relay contacts for electric strikes or for signalling the door status Technical data Ambient temperature 0 C to +50 C Voltage supply V DC ±15% Current consumption 0.1 W Relative humidity % (not condensed) Interfaces 3 x relay output ports (changeover contact 30 V/2 A) 4 x analogue input ports Connection Screw terminals 2.5 mm 2 Mounting On slot for WTC 200 WTX 200 I/O expansion Electronic Access Control SystemsDialock Wall TerminalFor indoor or outdoor use / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. WTX way relay module For expansion of WTC 200 controller WTX way relay module, as independent unit that can be installed remotely from the WTC 200 controller, e.g. as lift control. Technical data Degree of protection Depends on housing Ambient temperature (operation) 0 C to +50 C Voltage supply V DC ±15% Interfaces 3 x changeover contact 30 V/2 A 5 x make/break contact (relay) 1 x RS x analogue input port Relative humidity % (not condensed) Connection Screw terminals 2.5 mm 2 Functionality > Connection of up to 3 changeover contacts, 5 make or break contacts (relay) > RS-485 for connection with WTC 200 controller > One RS-485 interface on the WTC 200 can be used for operating up to 4 WTX 201 WTX way relay module DK ID 1872

27 Häfele Dialock WT 210 Wall Terminal Product overview Häfele Dialock WT 210 Wall TerminalProduct overviewplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Ordering product components Standard Optional E E! Page DK DK DK 6.1 DK DK DK " WT 210 wall terminal, (wall reader and controller, as one unit) Power supply Electric strike, reed sensor, multiple-locking device, motor mortice locks ESS 100 energy control terminal Automatic circuit breakers and relays Installation accessories Programming and user keys! For external doors made from wood, metal, glass or narrow frames EN 179 Doors with requirements on fire resistance/smoke control, EN 179 or EN 1125 are possible if the door structure also meets the respective requirements. " For interior doors made from wood, metal, glass or narrow frames EN 1125 EN 179 Doors with requirements on fire resistance/smoke control, EN 179 or EN 1125 are possible if the door structure also meets the respective requirements. DK EN 1125 Sample order Entrance door, projects, mains-operated wall terminal Wall terminal set WT 210 wall terminal DK E Power supply DC power supply unit, regulated DK E Lock Secury Automatic-A opener multiple locking device x lock case Angled security striking plate Optional E Automatic circuit breakers and relays DK E Installation accessories DK Automatic circuit breakers, relays and installation accessories as required Energy control terminal for hotels, additional wall reader on opposite side as required Programming and user keys DK ID 1872 DK 10.19

28 Häfele Dialock WT 210 Wall Terminal For indoor or outdoor use Electronic Access Control SystemsHäfele Dialock WT 210 TerminalFor indoor or outdoor useplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. WT 210 Wall terminal Space requirement flush-mount socket WT 210 wall reader (reader unit and controller in one compact unit) made from plastic, anthracite/silver coloured. The compact design of the WT 210 allows for installation in flush-mount sockets or cavity wall boxes. > Area of application: For controlling car park barriers, gates, any type of door, furniture and furnishings, lights, alarm systems, video surveillance,.. DK 2015, HDE-en, 07/15; Dimensional data not binding. We reserve the right to alter specifications without notice. Functionality Mains-operated wall terminal, for offline operation > Red/green LEDs for indication of locking and unlocking > The WT 210 forms a complete offline access point in combination with an electric strike > The digital input port can be used for connecting a push button inside that activates the electric strike, for example. > With integrated real-time clock for programming time restricted locking authorisations (setting of time zones) > With sabotage sensor that triggers the integrated signal generator and activates the alarm relay when removing the reader head from the installation frame > The alarm relay can also be combined with one further relay (in the protected (indoor) areas) in order to achieve a tamper-resistant access point > With audit trail of all locking processes and processes of removing the reader head from the installation frame > Wireless firmeware update with the MDU 110 Notes for operation and installation Please order supplementary and optional components, e.g. energy control terminal, power supply and lock, separately. Technical Data Degree of protection Ambient temperature (operation) Relative humidity IP65 25 C to +70 C % (not condensed) Voltage supply V DC ±15% Current consumption RFID Indication Interface Memory 0.8 W f = MHz 1 x LED red, 1 x LED green, Piezo sound generator Terminals mm 2 Dimensions Digital input port: Switching input max. 20 ma Relay output port (changeover contact): 48 V AC/DC, 5 A Alarm output port (make contact): 48 V DC, 1 A Rf interface for configuration with MDU 110 Event memory: Up to 1,000 audit trail entries Key memory: Up to 1,000 keys Width 81 mm, height 81 mm, depth 13 mm (surface mounted) 35 mm (flush mounted) Installation of wall reader in flush-mount socket with 2 device fastening screws (distance 60 mm in compliance with DIN). Make sure the fastening points on the flush-mount socket are horizontal. Minimum distance between 2 wall readers 250 mm. The installation of the wall reader in metal surroundings must be planned. 1 WT 210 wall terminal, offline WT 210 wall terminal with Bluetooth interface (HB) WT 210 wall terminal with open Bluetooth interface (SPK) WTX 202 relay unit (2 relays, 2 input ports) Ordering product components DK DK ID 1879

29 Dialock Wall Terminal E Supplementary products Electronic Access Control SystemsDialock Wall TerminalE Supplementary products / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. WTX 202 Relay unit ID 1879 DK Technical data Degree of protection IP 20 Ambient temperature (operation) 25 C to +65 C Voltage supply V DC (± 10%) Current consumption Power consumption Contact rating of relays Input ports Voltage Switching current Switching capacity Continuous current Communication interface Relative humidity <105 ma <1.3 W <60 V DC <1 A (momentary) <60 VA <x A 20 ma to optocoupler or control via a potential-free switch RS485 Possible wire thicknesses mm 2 Hat rail installation M36 rail technology A 10 95% (not condensed) AWG 4 joint units > Area of application: For extending the WT 210 wall terminal by 2 additional relays and 2 input ports > Version: Communication between the WTX 202 relay unit and the WT 210 wall terminal is encrypted with AES-128 > Installation: For clipping onto hat rail 1 WTX 202 relay unit (2 relays, 2 input ports) WT 210 wall terminal DK DK 2015, HDE-en, 07/15; Dimensional data not binding. We reserve the right to alter specifications without notice.

30 ID B

31 Häfele Dialock Wall Terminal E Supplementary products Häfele Dialock Wall TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Energy control terminal Circuit diagram D1872 DK Application Particularly suitable for use in hotels for activating electrical loads in guest rooms such as lighting, TV, sockets, air conditioning. Plastic housing white or silver coloured. Functionality > Activation of electric circuits and switching of electrical devices by means of Dialock keys with ISO credit card size via integrated switching contact. Activation as long as a transponder card is inserted in the holder of the energy control terminal. Every transponder card is authorised. > The electric circuits and switches are deactivated 20 seconds after the transponder card has been removed. > The LED (red) is only illuminated if no transponder is inserted in the holder. 1 energy control terminal with holder for transponder card Fixing material Box not supplied, please order separately. Technical data Certified in compliance with Power supply Contact rating Own consumption Life time FCC, EMC, SAA 230 VAC, 60/50 HZ Protection max. 25 A (8 A capacitive or 10 A inductive) <22 W or 100 ma Operating temperature 20 C to +70 C Relative humidity Ambient temperature (transport/storage) Time delay Technology >100,000 unlocking cycles (when using contact maker below 220 V and full load) 10 95% (not condensed) 20 C to +80 C 20 seconds Mifare Classic (with 4 or 7-Byte UID) Colour White Silver coloured Box DK 10.22

32 Häfele Dialock Wall Terminal E Supplementary products Häfele Dialock Wall TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Gira Frames 55 System For indoor use Gira E2 Häfele Dialock Wall TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. TX_44 System For outdoor use Degree of protection IP44 is achieved for the entire unit when combining the WT 140 Gira wall terminal set with the TX_44 system (frame, sealing flange and insert). Pure white, glossy Pure white, silk matt Aluminium coloured Anthracite Gira Esprit Pure white Anthracite Aluminium coloured Glass mint Glass white Glass black Aluminium coloured Colour 1-gang 2-gang Pure white Anthracite Aluminium coloured Brass plated Chrome plated Wenge wood IP44 Sealing flange for rocker switch Gira E22 Pure white Stainless steel coloured Model Colour 1-gang 2-gang E2 Pure white, glossy Pure white, silk matt Aluminium coloured Anthracite Esprit Glass mint Glass white Glass black Aluminium coloured Brass plated Chrome plated Wenge wood E22 Pure white Stainless steel coloured > Functionality: In conjunction with the TX_44 system frame and insert, a wide range of rocker switches is suitable for water-protected flush-mounted installation (degree of protection IP 44) > Colour: White Insert for TX_44 1-gang cover frame IP44 sealing flange Pure white > Functionality: In conjunction with the TX_44 system frame and the sealing flange, a wide range of rocker switches is suitable for water-protected flushmounted installation (degree of protection IP 44) Colour Pure white Anthracite Aluminium coloured DK ID A

33 Häfele Dialock Wall Terminal E Supplementary products Häfele Dialock Wall TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Accessories for Gira cover frame Room status indicator in hotels, with green and red LED 2-way rocker switch for room status indication in hotels > Functionality: With green and red 230-V-LED, marking and pictogram, "Do not disturb" (red) and "Make up room" (green) indicators, each half can be controlled separately, e.g. via series switch > Installation: In deep flush box in compliance with DIN Technical data Degree of protection IP 20 Operating temperature 15 C to +40 C Voltage supply Colour 230 V AC, 50 Hz Cream white glossy Pure white glossy Pure white, silk matt Anthracite Aluminium coloured > Functionality: Room status indicator "Do not disturb" and "Make up room", with interlock to prevent simultaneous switching, electrically and mechanically locked Colour Profile 55 Cream white glossy Pure white glossy Pure white, silk matt Anthracite Aluminium coloured Room status indicator in hotels, with labels Pure white Aluminium coloured ID 1872 DK > Functionality: Simple LED signalling for e.g. treatment rooms, conference rooms or hotel rooms, homogeneously illuminated area, divided into a red (top) and green (bottom) area each half can be controlled separately, e.g. via series switch Technical data Degree of protection IP 20 Operating temperature 15 C to +40 C Voltage supply Power consumption Light output 1 room status indicator in hotels 1 label "Bitte warten"/"bitte eintreten" 1 label "Do not disturb"/"make up room" 230 V AC, 50 Hz 1.0 W/5.6 VA 0.1 cd (red) 0.3 cd (green) Room status indicator in hotels B Colour 1-gang 2-gang Pure white Aluminium coloured Surface mounted box with cover frame Cream white glossy Pure white glossy > Dim. (W x D x H): 1-gang: 80 x 45.5 x 80 mm, 2-gang: 80 x x 45.5 mm Note Also suitable for WT 100 wall terminal set. Colour 1-gang 2-gang Cream white glossy Pure white glossy Gira frames DK A Box DK 10.22

34 ID C

35 WT Wall Terminal E Supplementary products WT Wall TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. For flush mounting WT Wall TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Small distributor Version: Material: Colour: 1 Box for flush mounting 2 Countersunk screws 15 mm Dimensions according to DIN standard Plastic Black Locking and securityelectronic locking systemplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. For installation in dry lining wall Box for flush mounting Area of application: Version: Material: Colour: For installation of safety transformer, automatic circuit breaker, installation control relay and electronic control unit module With top hat rail, IP 65 with door, IP 30 without door Housing: Plastic Housing: Grey Note Only IP65 versions are suitable for use with WTC 200. For drill hole q: 68 mm For table top thickness: 7 35 mm Version: With retaining edge, dimensions according to DIN standard Material: Plastic Colour: Red Box for installation in dry lining wall Flush-mount socket Degree of protection Dim. (W x D x H) mm IP65 IP30 14 joint units (single-row) 28 joint units (double-row) 12 joint units (single-row) 24 joint units (double-row) Electronic Locking SystemsF Processing and installationplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Cover strip for small distributor 300 x 142 x x 142 x x 99 x x 99 x ID 1856 DK Area of application: Material: Colour: Installation: WT Wall TerminalF Processing and InstallationPlanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Cavity wall box For DT Lite energy control terminal Plastic White For flush mounting Flush-mount socket Area of application: For energy control terminal Material: ABS plastic Colour: White For table top thickness: 7 15 mm Installation: For clamping in plasterboard with pan head H threaded screws M3, 5 x 30 mm Tested for fire resistance Cavity wall box Area of application: Colour: For 12 inserts Light grey WT Wall TerminalE Supplementary ProductsPlanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Top hat rail Cover strip for small distributor Standard: In compliance with EN Material: Steel Finish: Yellow chromatized Length: 2000 mm Top hat rail

36 WT Wall Terminal E Supplementary products WT Wall TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Cable transition, model Area of application: Installation: Length: Material: For current transfer from door frame to door, for cable Ø 7 mm, suitable for installation in wooden, plastic or metal doors Concealed, in door frame or in door leaf (optional) Flexible hose <110 mm Screw-on holder and hose: Stainless steel Model Please order mounting set for wooden doors separately. Cable transition Mounting set for wooden doors E Processing and installationplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Cable transition, models 10318, Area of application: For current transfer from door frame to door, for pulling flexible cable up to Ø 7 mm through Installation: Visible Length: Flexible hose: <180 mm with 10318, <300 mm with Material: Flexible hose: Rust-proof metal, screw-on holder: Plastic Finish: Screw-on holder: Nickel plated Model Cable transition DK ID 1840

37 WT Wall Terminal E Supplementary products WT Wall TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. PS 1 and PS 2 Power supply unit F Processing and InstallationPlanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Adapter cable AMP/bare Area of application: For supplying power to furniture terminals, wall terminals and multi-lock adapters Version: Plug-in connection to output cable with AMP plug (3-way AMP plug) on output port Technical data Input voltage Output voltage Relative humidity Mains lead length Output cable length Approvals V AC, Hz 12 V DC, regulated 0 95 % (not condensed) 1800 mm 1350 mm Operating temperature 0 50 C ACMA, CE, FCC, LPS, TÜV/GS, UL Area of application: For connecting the WT wall terminal or other devices with AMP socket to the PS 1/PS 2 power supply units Version: With AMP plug and wire end sleeves, with plastic sheathing HO3VVH2-F Colour: Black Technical data Cable length Power 250 mm 12 V, 6 A Plastic sheathing 2 x 0.75 mm 2 Adapter cable AMP/bare PS 1 or PS 2 power supply unit 1 Mains lead with Schuko safety plug 1 Supplementary sheet "Safety instructions" PS 1 power supply unit PS 2 power supply unit Output current A Dim. (L x W x H) mm x 42 x x 52 x For countries where a cable with DIN Schuko safety plug cannot be used, a cable in accordance with the national standard is available on request. DK 10.24

38 WT Wall Terminal E Supplementary products WT Wall TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. DC power supply unit, regulated WT Wall TerminalE Supplementary ProductsPlanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Rechargeable battery pack for emergency power supply Area of application: Power supply for wall terminal set, electric strike and motor lock Version: Suitable for permanent operation, short-circuit proof Installation: For installation in distributor on hat rail Technical data Input voltage Output voltage Output current Width 36.1 mm 2 A Width 72 mm V AC 12 V DC 4 A Operating temperature Width 36.1 mm <40 C Hat rail installation M36 rail technology Width 72 mm <50 C Width 36.1 mm Width 72 mm 2 joint units 4 joint units Area of application: Version: Installation: Low-cost power supply for e.g. wall terminal set, electric strike, motor lock Hermetically sealed lead battery pack with 12 V (4Ah), suitable for permanent operation, maintenance free, a second terminal is provided on the battery pack for connecting the load For installation in distributor on hat rail Note Installation and commissioning must be carried out by a qualified electrician. 1 DC power supply unit 1 Wall mounting set 1 Snap-on cover Width mm Technical data Input voltage Output voltage Capacity Nominal capacity (example) Operating temperature Hat rail installation M36 rail technology Service life Self-discharge 12.8 V DC 12 V DC 4 Ah 120 W, for 10 min. <40 C 9 joint units approx. 5 years (ambient temperature 20 C) Installation For use in combination with 12 V DC power supply unit (e.g ). The output voltage of the DC power supply unit must be increased to 13.8 V DC, power consumption of the battery pack is then ma (load capacity). The battery pack must be connected between power supply unit and consumer. Note Installation and commissioning must be carried out by a qualified electrician. Width mm approx. 3 % per month (ambient temperature 20 C) DK 10.25

39 WT Wall Terminal E Supplementary products WT Wall TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. DC power supply unit, unregulated F Processing and installationplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Time delay relay Area of application: Version: Standard: Power supply for wall terminal set, electric strike and motor lock Suitable for permanent operation, not short circuit proof In compliance with EN, VDE, UL, CSA Area of application: In combination with the ESS energy control terminal Functionality: Delayed switching off of connected load, when the control contact is closed, the normally open contact also is closed. After opening the control contact, the normally open contact remains closed during the delay time. Technical data Input voltage Output voltage Output current 230/115 V AC 12 V DC 3 A Operating temperature 20 to +80 C W x D x H Hat rail installation M36 rail technology 50 x 92 x 95/75 mm 3 joint units Technical data Nominal contact rating Voltage supply Delay time 10 A/250 V AC V AC/DC 0 10 min Note Installation and commissioning must be carried out by a qualified electrician. Width mm Note Installation and commissioning must be carried out by a qualified electrician. Time delay relay DK 10.26

40 WT Wall Terminal E Supplementary products WT Wall TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Automatic circuit breaker Electronic Access Control SystemsF Processing and installationplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Installation control relay Area of application: For protection of the electric circuit of wall terminals Material: Housing: Plastic Colour: Housing: Grey Installation: For installation in distributor on hat rail Standard: In compliance with DIN VDE for line protection Technical data Output current Hat rail installation M36 rail technology 5 A 1 joint unit Note Installation and commissioning must be carried out by a qualified electrician. Automatic circuit breaker Area of application: Technical data For activating the WT 210 after a power failure, The WT 210 can be installed tamper-proof with this circuit Functionality: If a WT 210 is removed from its installation frame an alarm is triggered and the installation control relay disconnects the power supply to the electric strike, for example. The door cannot be opened any more. Functionality is not restored again until the WT 210 has been installed and a button has been pressed. Material: Colour: Installation: Control voltage Nominal contact rating Hat rail installation M36 rail technology Housing: Plastic Housing: Grey/blue For installation in distributor on hat rail V UC 16 A/230 V AC 1 joint unit F Processing and installationplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Installation control relay Area of application: Material: Colour: Installation: Technical data Control voltage Nominal contact rating Hat rail installation M36 rail technology For switching voltages > 60 V Housing: Plastic Housing: Grey For installation in distributor on hat rail V UC 16 A/250 V AC (changeover contact) 1 joint unit Note Installation and commissioning must be carried out by a qualified electrician. Observe correct polarity with direct current control. Installation control relay Note Installation and commissioning must be carried out by a qualified electrician. Packing: 1 piece Installation control relay In case of power failure or manipulation of the WT 210 wall reader, the reader is deactivated and the door cannot be opened any more. In order to make emergency opening of the door possible in this situation, a profile cylinder must be installed on site. DK 10.27

41 Programming and User Keys Information Electronic Access Control SystemsProgramming and User KeysInformationPlanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Programming You have decided to install a door terminal (DT), wall terminal (WT) or furniture lock. Now you can define the procedure that is used to program the electronics, or decide which key (user key) will be given authorisation to open the lock. You have the choice between two programming methods: Key card programming for small projects Software programming for large projects and extensive functionality (SW software) Overview of advantages and usage areas Key card programming Software programming D1870 DK Key card programming is ideal for projects comprising up to about 20 doors and 20 keys. The advantages thereof are low administrative cost and ease of use. The authorisation for the door is assigned directly at the respective terminal (DT or WT) using an electronic key (user key) and a programming key card. If the authorisation is to be withdrawn, it is deleted using a clearing key card and the relevant electronic keys (user key). Once Dialock terminals have been configured with software using the MDU, key card programming is no longer possible. User keys The responsible Häfele employees or the specialists in the project area will help you to plan. Software programming is ideal for all projects. The advantage is the efficient management of authorisations and all settings for the locking system on a PC using special software. The authorisations (assigning or deleting) of the electronic keys (user key) are assigned either directly at the encoding station (ES 110) or wall reader (WRU 200) that is individually positioned on or inside the building. The advantage of the software is the visual display, management and storage of the authorisations on the PC and extended functionality such as group definitions, series programming, role concepts, setting the date and time, incorporation of external software and all system parameters... Continue to page DK Continue to page DK User keys are the electronic version of keys. They must first have access authorisation assigned to them (programming: Stand Alone SA or software SW) so that they can then be used during everyday operations. The user keys are maintenance free (no battery) and wear and tear free (contactless data transfer). Continue to page DK 10.32

42 Programming Electronic Access Control SystemsProgrammingPlanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Dialock Software The USB stick version must be ordered when the software is procured for the first time. This is because the USB stick contains further extensive system descriptions besides the software. Delivery via mail is used for software extension and should only be selected for an inital procurement after approval. Project size Access points SW 200 Control software Personnel master records SW 300 Hotel software SW 400 Professional software Licence for encoding station, WT 200 Online, authorisation writer * in the hotel environment (+HMS), the guest cards are allocated to the access point (guest room door). Functionality (supplementing in ascending order) locking map + time and attendance + HMS (interface) + role model Software: Delivered on USB stick Software SW Dialock software manual Installation and operating instructions for the Dialock door and wall terminals License file (on USB stick) License key (on USB stick) Software extension: Delivery of the license via mail/fax License file (via mail) License key (via fax) Ordering information for sending of license by mail/fax If the delivery is made by mail/fax it is assumed that the Dialock software is already present in the project. The following information is needed for an order: Project name Project address Project code from software Mail address (for sending license file) Fax number (for sending license key) Ordering procedure The license will be produced after the information has been checked. First the license file will be sent to the defined authorised person in the project by mail. Then the license key will be sent to the specified fax number, or alternatively, if no fax is available, in exceptional cases the license key can be provided over the telephone. Delivered on USB stick Please check your order very carefully. The licence cannot be returned because of the customised configuration of the software. Please keep the USB stick and all licences in a safe place. For your own security, these should only be made available to authorised persons. Copying of the software and the licences is permitted for the ordered project. Linking to a hotel administration programme may cause additional costs (interface programming). Please discuss with the software manufacturer and order, if required. Delivery via mail Software SW 200 Control 20/ Software SW 200 Control 50/ Software SW 200 Control 100/ Software SW 200 Control 200/ Software SW 200 Control 500/ Software SW 300 Hotel 20/ Software SW 300 Hotel 50/ Software SW 300 Hotel 100/ Software SW 300 Hotel 200/ Software SW 300 Hotel 500/ Software SW 400 Professional 50/ Software SW 400 Professional 100/ Software SW 400 Professional 200/ Software SW 400 Professional 500/ SW 400 Professional demo version DK ID 1849

43 Programming Electronic Access Control SystemsProgrammingPlanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Dialock Software extension Software extension: Delivered on USB stick Software SW Installation and operating instructions for the Dialock door and wall terminals License file (on USB stick) License key (on USB stick) Software extension: Delivery of the license via mail/fax License file (via mail) License key (via fax) Please check your order carefully. Because of the customer-specific configuration of the software, the license cannot be returned. Please keep the USB stick and all licenses in a safe place. It is in your own interest to ensure that these can only be accessed by authorised persons. The software and the licenses may be copied for the ordered project. Packing: 1 piece Delivered on USB stick Delivery via mail 8 additional authorisation writers online additional authorisation writers online Installation of software on additional workplace computer (starting from the 21st workplace computer) additional access points additional access points additional access points additional access points additional personnel master records additional personnel master records additional personnel master records additional personnel master records Electronic Access Control SystemsProgrammingFor small projects / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. PK key card Electronic Access Control SystemsProgrammingFor small projects / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. PK Clearing key card Area of application: Dim.: Small projects with few Dialock keys 54 x 85 mm (credit card size) Functionality For allocating access authorisations without software and programming station Technology Mifare Classic Area of application: Dim.: Small projects with few Dialock keys 54 x 85 mm (credit card size) Functionality For deleting access authorisations without software and programming station Technology Mifare Classic DK 10.30

44 Programming Electronic Access Control SystemsProgrammingPlanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. ES 110 Encoding station Area of application: Version: Material: Colour: For programming transponder media LCD display, background lighting Housing: Plastic Housing: Silver coloured/grey Planning by Dialock specialist is required. Please ask Functionality The authorisation data that were allocated with the Dialock software are transferred via the TCP/IP network to the ES 110 and written onto the presented transponder medium. The system is operated using the Dialock software or the integrated HMS hotel management system. Configuration of the ES 110 is carried out on a PC and its web interface (browser) via the TCP/IP network to the ES 110. Technical data Voltage supply Current consumption Display Connections Data transfer Dimensions PoE Power over Ethernet with PoE splitter (not supplied) or PS6 external power supply unit max. 300 ma 128 x 64 pixels RJ45 socket for connecting the programming cable to the PC between PC and ES 110 via TCP/IP Length 185 mm, width 130 mm, height 57 mm 1 ES 110 encoding station 1 Patch cable Cat 5, 2 m 1 PS6 external power supply unit Short instructions Technology Tag-it TM -ISO, Legic, Legic advant and Mifare Classic Electronic Access Control SystemsProgrammingPlanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. MDU 110 Mobile data unit Planning by Dialock specialist is required. Please ask. Technical data Voltage supply Service time Weight including batteries Display Connections Internal data memory Security Lithium-ion battery, charged using USB connection 24 h, when operating without background lighting (can be switched off) approx. 400 g 128 x 64 pixel, 6 lines USB 2.0 interface for connection with the PC 4 GB, corresponds to approx terminal data records Encrypted storage of data and data transfer between MDU 110 and terminals 1 MDU 110 mobile data unit 1 USB 2.0 cable (1.5 m) for connecting MDU 100 with the PC Area of application: For transferring data and configurations from the PC (Dialock software) to offline terminals Version: LCD display, background lighting, 5 language settings Material: Housing: Plastic Colour: Housing: Anthracite, similar to RAL 7020 Functionality Operation is carried out using the "clickwheel" (one-handed operation) on MDU 110. A USB 2.0 interface is used for communication with the PC which is recognised by the PC as mass storage device. Installation of drivers is therefore not necessary. Data exchange with the terminals takes place via wireless interface. This also applies to firmware updates that may be required. Language Technology German, English, French, Italian and Spanish Tag-it TM -ISO, Legic advant and Mifare Classic DK 10.31

45 Userkeys Electronic Access Control SystemsUserkeysPlanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. The transponders depicted in our catalogues are of high quality and have been tested by us on all Dialock components. The transponders are provided with a security key and Dialock segmentation for increasing the security of the Dialock access control system. Please contact our Dialock specialists if you have further questions. KC Key card User KeysPlanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Card holder and short clip Blank card Card holder without short clip ID 1880 DK Card, printed on both sides > Version: Wear and tear free (contactless data transfer), maintenance-free (without batteries), insensitive to external influences such as wetness, moisture, magnetic fields, mechanical vibrations, dust, can be reprogrammed at least 100,000 times, forgery-proof unique number > Material: Plastic > Colour: White Technical data Data retention >10 years Operating temperature 35 C to +50 C Dim. Legic and Mifare cards 54 x 86 x 0.76 mm Not printed Tag-it TM ISO cards Printed on both sides Technology Customised imprint on request: Print and customise. 54 x 86 x 0.86 mm Tag-it TM ISO Mifare Classic Tag-it TM ISO Mifare Classic > Area of application: For accommodating and protecting key cards > Version: 3 fixing methods for right, left or vertical dispense > Material: Plastic > Finish: Transparent 50 card holders Other card holders on request. Short clip 50 short clips Card holder > Area of application: For attaching the card holder to a piece of clothing > Version: Plastic double inset Short clip

46 User Keys User KeysPlanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. KT Key tag User KeysPlanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. KT Key tag Version: Material: Waterproof Plastic Functionality Electronic keys for Dialock as key tag 4 independent locking authorisations per key tag possible Technical data Data storage >10 years Operating temperature 35 C to +50 C Technology Colour Tag-it TM ISO Black Blue Red Mifare Classic Black Blue Red Note A dark day can adversely influence the turn-on characteristics with older door terminal versions (visual process). In this case use a different colour. The terminals in this catalogue are not affected thereof. Functionality: Electronic keys for Dialock as key tag, 4 independent locking authorisations per key tag possible Version: Solid, ultrasound welded and made waterproof Material: Combination of stainless steel frame and impact resistant polycarbonate Finish: Matt Technical data Data storage Dimensions >10 years Ø 36 mm, height: 5.3 mm Operating temperature 35 C to +50 C Transponder Tag-it TM ISO or Mifare Classic Colour Tag-it TM ISO Mifare Classic White Black Green Red Blue Orange Text imprint or photo/graphic (template with min. 300 dpi required) on request. DK 10.33

47 User Keys Electronic Access Control SystemsUser KeysPlanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. KC Key card with individual print Electronic Access Control SystemsUser KeysPlanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Certification of external transponders Application examples for key cards with individual print The Dialock system will work with all transponders that are compatible with the transponder technologies used by Dialock. Problem-free operation with the Dialock system cannot be guaranteed for every transponder because of the diversity and variable quality of the transponders on the market. It is therefore advisable to have external transponders certified by Häfele before using Dialock. The functionality of the external transponders will be tested at all Dialock terminals and the performance thereof measured during the certification process. Problem-free operation of the transponders with the Dialock system can only be guaranteed after certification has taken place ID 1853 Planning by Dialock specialists is required. Functionality: Version: Material: Colour: Technical data Data storage Ambient temperature (operation) Coating DK Dimensions Transponder Reusable Version: Technology Electronic key for Dialock Wear and tear free (contactless data transfer), maintenance-free (without batteries), insensitive to external influences such as wetness, moisture, magnetic fields, mechanical vibrations, dust, forgery-proof unique number, mass printing procedure Plastic Base colour white, print in accordance with customer specifications >10 years 35 C to +50 C Print, customise and price on request. Minimum order quantity: 50 pieces. 4 colours (optionally on one side or both sides) 54 x 85 mm (credit card size) Mifare Classic Can be reprogrammed at least 100,000 times Mifare Classic Certification process The range and usability of 5 samples of an external transponder (same model, same technology card, tag or hybrid) will be tested at all Dialock terminals. Häfele will produce a test report and issue an approval in the event of a positive test result. Problem-free operation of the transponders with the Dialock system can only be guaranteed after certification has taken place. Certification of external transponders Please provide 5 samples of an external transponder for testing. The external transponders will be retained by Häfele as reference samples.

48 DT 510 Door Terminal Product overview DT 510 Door TerminalProduct overviewplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Ordering product components! Standard Optional G E G Page DK / DK DK / DK DK DK DK Continue to step 3 " DT 510 thumbturn cylinder DT 510 double cylinder DT 510 thumbturn cylinder, dummy on one side DT 510 cylinder with thumbturn Tool set Optional versions Supplementary products, service and maintenance Programming and user keys! For wooden, glass, narrow frame or metal external doors, in compliance with VdS 2156BZ " For wooden, glass, narrow frame or metal interior doors, in compliance with VdS 2156BZ EN 179 EN 1125 EN 179 EN 1125 DK ID 1804 DK Mortise lock, glass door fittings, striking plate and lever handle aperture parts are optional and must be selected in accordance with the door requirements (fire resistance and smoke control, EN 179, EN 1125). Information about processing and installation can be found in our online shop "Easy link" Sample order Glass door in residential areas, glass thickness 10 mm, battery-operated door terminal Battery-operated door terminal DT 510 D thumbturn cylinder dim. A 27.5 mm, dim. B 27.5 mm G Service and maintenance DK Tool set DK E Supplementary products DK Continue to step 3: Programming and user keys DK 10.28

49 DT 510 Door Terminal For standard/fr interior or external doors 510 Door TerminalElectronic Access Control SystemsFor standard/fr interior or external doorsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. DT 510 D, DT 510 D-DZ, DT 510 B and DT 510 H Electronic thumbturn or double cylinder DT 510 D thumbturn cylinder DT 510 B thumbturn cylinder, dummy on one side DT 510 D-DZ thumbturn cylinder DT 510 H single cylinder with thumbturn ID 1892 DK Electronic thumbturn or double cylinder with PC shape for inserting in mortice locks that comply with DIN For door thickness from 40 to 110 mm. Functionality Battery-operated, intelligent thumbturn or double cylinder, touch-free activation with Dialock key Profile cylinder with reader on one side (thumbturn cylinder) or both sides (double cylinder) for access control Acoustic feedback when presenting the key Illuminated ring for indication of status: Green = unlocking, red = locking, no LED = stand-by Standard setting: Activation of external knob with authorized Dialock key and automatic deactivation after 10 seconds (variable time setting) For service personnel: Indication of programming status and when battery change is required (acoustic alarm signal) Infrared interface for programming With real-time clock and audit trail of all processes The following is required for ordering Selection of standard/fire resistant interior or external doors Determination of the required version, DT 510 D, DT 510 D-DZ, DT 510 B and DT 510 H Determination of cylinder lengths, dim. A and dim. B Optional versions Further optional versions can be ordered in addition to the depicted standard product range. Available special features: Other profile cylinder lengths, dim. A and dim. B up to 87.5 mm (up to 175 mm total length) Thumbturn characteristics/finish (soft-touch coating) Different finishes available on request Increasing the fire resistance category from T30 to T90 Drilling and pull protection in compliance with VdS 2156 BZ Version for gearbox door locks with smooth operation Shouldered cylinder, e.g. in combination with door backplates with cylinder cover (not available for DT 510 H) Technical data Technology Degree of protection Ambient temperature (operation) Relative humidity Prohibited climates Mifare Classic IP65 Weatherproof, for use inside and outside of buildings 20 C to +70 C 0 95 % (not condensed) Fire resistance category T30 (T90 optional) Battery Profile cylinder lengths Number of possible Dialock keys Not suitable for use in corrosive environment (chlorine, ammoniac, lime water) Service life: approx. 2 years with average use (approx. 40,000 locking processes) Approved battery type: Panasonic Industrial Lithium (CR-2 Lithium) 27.5 mm to 62.5 mm 1000 Notes for operation and installation PC cylinder adapter and reader head are explicitly linked with an internal code. This means that changing the reader head only is not possible. A mortice lock in compliance with DIN and the tool set are required for installation. Combination with padlocks with PC aperture for outdoor use is possible. Battery change Only use Panasonic Industrial Lithium batteries type CR-2. We recommend changing the batteries before the winter months when using the electronic cylinder outdoors. Avoid storage with inserted battery (increased discharge). Ordering product components DK DT 510 D thumbturn cylinder DK DT 510 D-DZ double cylinder DK DT 510 B thumbturn cylinder, dummy on one side DK DT 510 H single cylinder with thumbturn DK Version in compliance with EN 179 / EN 1125 DK DT 510 optional versions DK Supplementary products DK

50 DT 510 Door Terminal For standard/fr interior or external doors Electronic Access Control SystemsDT Door TerminalFor standard/fr interior or external doors / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. DT 510 D Thumbturn cylinder Dim. A and dim. B are available with max. length of 87.5 mm. The total length dim. C is therefore max. 175 mm. Special lengths that are not depicted here must be ordered under For more information please see optional versions. Installation conditions dim. A The PC profile must be flush with the door handle set (backplate or escutcheon) or may only project by max. 3 mm. Version: Material: Finish: With electronic reader head (dim. A) and thumbturn (dim. B) PC housing: Brass, reader head and thumbturn: Stainless steel, reader unit: Plastic PC housing: Nickel plated, reader head and thumbturn: Matt 1 DT 510 D thumbturn cylinder 1 Forend screw 1 Battery, type CR 2, 3V lithium Short installation instructions Dim. A Dim. B Dim. C mm mm mm Please order mortise lock or door handle set separately. Dim. A Dim. B Dim. C mm mm mm Ordering product components DK Version in compliance with EN 179 / EN 1125 DK DT 510 optional versions DK Supplementary products DK DK ID 1804

51 DT 510 Door Terminal For standard/fr interior or external doors Electronic Access Control SystemsDT Door TerminalFor standard/fr interior or external doors / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. DT 510 D-DZ Double cylinder Dim. A and dim. B are available with max. length of 87.5 mm. The total length dim. C is therefore max. 175 mm. Special lengths that are not depicted here must be ordered under For more information please see optional versions. Installation conditions dim. A The PC profile must be flush with the door handle set (backplate or escutcheon) or may only project by max. 3 mm. Version: Material: Finish: With 2 electronic reader heads (dim. A = external side) PC housing: Brass, reader head and thumbturn: Stainless steel, reader unit: Plastic PC housing: Nickel plated, reader head and thumbturn: Matt Dim. A = external side 1 DT 510 D-DZ double cylinder 1 Forend screw 2 Batteries, type CR 2, 3V lithium Short installation instructions ID 1804 DK Dim. A Dim. B Dim. C mm mm mm Version in compliance with EN 179 / EN 1125 not available. Please order mortise lock or door handle set separately. Dim. A Dim. B Dim. C mm mm mm Ordering product components DK DT 510 optional versions DK Supplementary products DK

52 DT 510 Door Terminal For standard/fr interior or external doors Electronic Access Control SystemsDT Door TerminalFor standard/fr interior or external doors / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. DT 510 B Thumbturn cylinder, dummy on one side Dim. A and dim. B are available with max. length of 87.5 mm. The total length dim. C is therefore max. 175 mm. Special lengths that are not depicted here must be ordered under For more information please see optional versions. Installation conditions dim. A The PC profile must be flush with the door handle set (backplate or escutcheon) or may only project by max. 3 mm. Version: Material: Finish: With electronic reader head (dim. A) and dummy (dim. B) PC housing: Brass, reader head and thumbturn: Stainless steel, reader unit: Plastic PC housing: Nickel plated, reader head and thumbturn: Matt 1 DT 510 B thumbturn cylinder, with dummy on one side 1 Forend screw 1 Battery, type CR 2, 3V lithium Short installation instructions Dim. A Dim. B Dim. C mm mm mm Please order mortise lock or door handle set separately. Dim. A Dim. B Dim. C mm mm mm Ordering product components DK Version in compliance with EN 179 / EN 1125 DK DT 510 optional versions DK Supplementary products DK DK ID 1804

53 DT 510 Door Terminal For standard/fr interior or external doors Electronic Access Control SystemsDT Door TerminalFor standard/fr interior or external doors / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. DT 510 H Single cylinder with thumbturn Dim. A is available with max. length of 87.5 mm. The total length dim. C is therefore max mm. Special lengths that are not depicted here must be ordered under For more information please see optional versions. Installation conditions dim. A The PC profile must be flush with the door handle set (backplate or escutcheon) or may only project by max. 3 mm. Version: With electronic reader head (dim. A) Material: PC housing: Brass, reader head and thumbturn: Stainless steel, reader unit: Plastic Finish: PC housing: Nickel plated, reader head and thumbturn: Matt 1 DT 510 H single cylinder with thumbturn 1 Forend screw 1 Battery, type CR 2, 3V lithium Short installation instructions Dim. A Dim. B Dim. C mm mm mm ID 1804 DK Version in compliance with EN 179 / EN 1125 not available. Please order mortise lock or door handle set separately. Ordering product components DK DT 510 optional versions DK Supplementary products DK

54 DT 510 Door Terminal For doors in compliance with EN 179/EN 1125 Electronic Access Control SystemsDT Door TerminalFor doors in compliance with EN 179/EN 1125Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. DT 510 D-P, DT 510 B-P Electronic thumbturn or double cylinder DT 510 D-P thumbturn cylinder DT 510 B-P thumbturn cylinder, dummy on one side Electronic thumbturn cylinder with PC shape for inserting in mortise locks that comply with DIN and with appropriate approval in accordance with EN 179 or EN For door thickness from 40 to 110 mm. Profile cylinder with defined locking lug position Functionality Battery-operated, intelligent thumbturn or double cylinder, touch-free activation with Dialock key Profile cylinder with reader on one side for access control Acoustic feedback when presenting the key Illuminated ring for indication of status: Green = unlocking, red = locking, no LED = stand-by Standard setting: Activation of external knob with authorized Dialock key and automatic deactivation after 10 seconds (variable time setting) For service personnel: Indication of programming status and when battery change is required (acoustic alarm signal) Infrared interface for programming With real-time clock and audit trail of all processes The following is required for ordering Selection for escape routes and panic areas in compliance with EN 179 or EN 1125 Determination of required version, DT 510 D-P or DT 510 B-P Determination of cylinder lengths, dim. A and dim. B Optional versions Further optional versions can be ordered in addition to the depicted standard product range. Available special features: Other profile cylinder lengths, dim. A and dim. B up to 87.5 mm (up to 175 mm total length) Thumbturn characteristics/finish (soft-touch coating) Different finishes available on request Increasing the fire resistance category from T30 to T90 Drilling and pull protection in compliance with VdS 2156 BZ Shouldered cylinder, e.g. in combination with door backplates with cylinder cover Technical data Technology Degree of protection Ambient temperature (operation) Relative humidity Prohibited climates Mifare Classic Must not be exposed to the weather 20 C to +70 C 0 95 % (not condensed) Fire resistance category T30 (T90 optional) Service life of battery Profile cylinder lengths Number of possible Dialock keys Not suitable for use in corrosive environment (chlorine, ammoniac, lime water) approx. 2 years with average use (approx. 40,000 locking processes) 27.5 mm to 62.5 mm 1000 Audit trail entries 500 Notes for operation and installation Planning must be carried out by Dialock specialist PC cylinder adapter and reader head are explicitly linked with an internal code. This means that changing the reader head only is not possible. A mortise lock in compliance with DIN and with appropriate approval in accordance with EN 179 or EN 1125 and the tool set are required for installation. Battery change Only use Panasonic Industrial Lithium batteries type CR-2. Avoid storage with inserted battery (increased discharge). Ordering product components DK DT 510 D-P thumbturn cylinder DK DT 510 B-P thumbturn cylinder, dummy on one side DK Standard/fire resistant version DK DT 510 optional versions DK Supplementary products DK DK ID 1892

55 DT 510 Door Terminal For doors in compliance with EN 179/EN 1125 Electronic Access Control SystemsDT Door TerminalFor doors in compliance with EN 179/EN 1125 / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. DT 510 D-P Thumbturn cylinder Dim. A and dim. B are available with max. length of 87.5 mm. The total length dim. C is therefore max. 175 mm. Special lengths that are not depicted here must be ordered under For more information please see optional versions. Installation conditions dim. A The PC profile must be flush with the door handle set (backplate or escutcheon) or may only project by max. 3 mm. Version: Material: Finish: With electronic reader head (dim. A) and thumbturn (dim. B) PC housing: Brass, reader head and thumbturn: Stainless steel, reader unit: Plastic PC housing: Nickel plated, reader head and thumbturn: Matt Must not be exposed to the weather 1 DT 510 D-P thumbturn cylinder 1 Forend screw 1 Battery, type CR 2, 3V lithium Short installation instructions ID 1804 DK Dim. A Dim. B Dim. C mm mm mm Version with degree of protection IP65 is not available. Please order mortise lock or door handle set separately. Dim. A Dim. B Dim. C mm mm mm Ordering product components DK Standard/fire resistant version DK DT 510 optional versions DK Supplementary products DK

56 DT 510 Door Terminal For doors in compliance with EN 179/EN 1125 Electronic Access Control SystemsDT Door TerminalFor doors in compliance with EN 179/EN 1125 / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. DT 510 B-P Thumbturn cylinder, dummy on one side Dim. A and dim. B are available with max. length of 87.5 mm. The total length dim. C is therefore max. 175 mm. Special lengths that are not depicted here must be ordered under For more information please see optional versions. Installation conditions dim. A The PC profile must be flush with the door handle set (backplate or escutcheon) or may only project by max. 3 mm. Version: Material: Finish: With electronic reader head (dim. A) and dummy (dim. B) PC housing: Brass, reader head and thumbturn: Stainless steel, reader unit: Plastic PC housing: Nickel plated, reader head and thumbturn: Matt Must not be exposed to the weather 1 DT 510 B-P thumbturn cylinder, with dummy on one side 1 Forend screw 1 Battery, type CR 2, 3V lithium Short installation instructions Dim. A Dim. B Dim. C mm mm mm Version with degree of protection IP65 is not available. Please order mortise lock or door handle set separately. Dim. A Dim. B Dim. C mm mm mm Ordering product components DK Standard/fire resistant version DK DT 510 optional versions DK Supplementary products DK DK ID 1804

57 DT 510 Door Terminal E Supplementary products Electronic Access Control SystemsDT Door TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. DT 510 Optional versions A data sheet with mandatory (required fields) and optional (optional fields) specifications must be provided when ordering. A fillable PDF form can be found in our online system "Easy link". Area of application A range of version options with customised DT 510 door terminal (from an order quantity of 1 piece) is available in addition to the standard versions. A Dialock specialist is mandatory for planning these approx other versions. Version* Description Notes DT profile cylinders FH T90 ( ) VdS ( ) VL ( ) ST ( ) SB ( ) D-GS ( ) B-GS ( ) Fire resistance up to 90 minutes Version with drilling and pull protection in compliance with VdS 2156 BZ Extension on one side dim. A / dim. B: mm Soft-touch coating on reader head Offset cylinder For gearbox door locks with extremely smooth operation For gearbox door locks with extremely smooth operation Dim. A: From 32.5 mm Dim. B: From 27.5 mm * do not use specified Cat. Nos. for ordering, these cause incorrect items in your order. Total length max. 175 mm (one side max mm) Thumbturn colour: Black Dim. A: From 27.5 mm Dim. B: From 32.5 mm Dim. A: From 27.5 mm Dim. B: From 32.5 mm 510 D 510 D-DZ 510 B 510 H 510 D-P 510 B-P ID 1892 Version Description Cylinder specifications Ordering example Required fields Optional fields Required number of DT Room designation/no. Room 1.15 Full model designation Dim. A (S): from 67.5 mm extension VL Dim. B (K): from 67.5 mm extension VL Transponder technology FH T90 Fire resistance up to 90 minutes Yes VdS With drilling and pull protection No VL Extension Dim. A ( mm) No Dim. B ( mm) ST Soft-touch coating on reader head No SB Offset cylinder No D-GS Gearbox door locks with extremely smooth operation No B-GS DK DT 510 D 27.5 mm 37.5 mm Mifare Classic No No Optional versions of DT

58 DT 510 Door Terminal E Supplementary products G service and maintenance DT 510 Door TerminalE Supplementary products G service and maintenanceplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Tool set Sealing ring Area of application: For removing the reader cover from the reader head, required for changing the battery Tool set Area of application: For sealing the reader head Installation: For inserting in locking ring Sealing ring Electronic Access Control SystemsG Service and maintenanceplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Battery DT 510 Door TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Replacement thumbturn Area of application: For supplying power to the DT 510 door terminal 1 Battery, type CR2, 3V lithium DT 510 Door TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Reader cover G Service and maintenanceplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Locking ring G Service and maintenanceplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Battery Material: Installation: Finish Stainless steel Tool set required for changing the reader cover Satin With black soft-touch coating Area of application: Version: Installation: Connecting element between profile cylinder and reader head With black sealing ring For plug-fitting and screw fixing Locking ring Area of application: Replacement thumbturn for DT 510 D and DT 510 D-P thumbturn cylinder Material: Stainless steel Finish: Satin Installation: Fixing with grub screw SW 2.5 G Service and maintenanceplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Cover plate For covering the edge of the drillings for TSE door terminals Note Also suitable for the use on fire resistant and smoke control doors. 2 cover plates are required for 1 door. Replacement thumbturn Area of application: Material: Finish: Dim. (L x W): TSE door terminal For covering the installation holes (with possible colour deviations and pressure marks) when replacing TSE door terminals with DT 400 or DT 510 door terminals Stainless steel Satin 310 x 72 mm Cover plate DK ID 1892

59 DT 100 Door Terminal Product overview DT 100 Door TerminalProduct overviewplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Ordering product components Standard Optional B C D E F G! " Page DK / DK DK 6.6 DK DK DK DK DK DK Continue to step 3 Door terminal set Mortice lock Mortice lock with requirements on fire resistance and smoke control Striking plate Lever handle aperture parts Profile cylinder for emergency opening Mounting material for other door thicknesses Mounting material for other door thicknesses with requirementson fire resistance and smoke control Glass mounting adapter with mortice lock Accessories for processing and installation Maintenance tools and batteries Programming and user keys! For interior doors, wood ID 1815 " For interior doors, glass For interior doors, metal Information about processing and installation can be found in our online shop "Easy link" Sample order For wooden interior door, rebated, 42 mm, DIN left, backset 55 mm, battery-operated door terminal DK ^ Door terminal set DK DT 100 door terminal set, satin stainless steel, exterior module with lever handle pointing to the left, with U-shaped lever handle design B Mortise lock DK For doors with standard requirements, for residential areas, with deadlocking latchbolt and Quiet-Comfort, satin stainless steel Flanged striking plate DK 6.8 D Profile cylinder for mechanical emergency opening DK F Accessories for processing and installation DK G Maintenance tool DK Optional Punched hole for internal backplate (for mechanical emergency opening) DK Continue to step 3 Programming and user keys DK DK

60 DT 100 Door Terminal For interior doors Electronic Access Control SystemsDT Door TerminalFor interior doorsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. DT 100 Door terminal set, for doors with standard requirements Backplate exterior module with processor (access control) Backplate interior module Door terminal sets for interior doors, backplates (cover hoods) made from ABS plastic, satin stainless steel coloured, stainless steel lever handle aperture parts Functionality Battery-operated, intelligent door terminal, touchless activation with Dialock key Red/green LEDs for indication of locking and unlocking Standard setting: Unlocking with Dialock key and automatic locking after 3 seconds The door can be opened without a key at any time from the inside. Electromotive locking, magnetic interactions cannot take place For service personnel: Indication of programming status and when battery change is required With real-time clock and audit trail of all processes Unlocking and locking with Dialock key (toggle mode) RFID interface in exterior module for programming Electric pushbutton on the inseide for "Do not disturb" and other functions Options (please order separately) Mechanical emergency opening with single profile cylinder Visible punched hole of cover hoods with mechanical emergency opening with single profile cylinder Other lever handle designs on request Macros for extension of functions available on request Technical data Technology Degree of protection Ambient temperature (operation) Relative humidity Life time of battery Memory Spindle Door thickness Mounting material Mifare Classic IP20 0 C to +55 C 0 95 % (not condensed) approx. 2 years or 22,000 locking and unlocking processes Event memory: up to 1,000 audit trail entries Key memory: up to 1,000 keys 8 mm mm For door thicknesses mm, if not ordered for other door thicknesses Electro-static discharge (ESD) High level security, tested to 20,000 V (standard 8,000 V) Voltage supply Notes for operation and installation Alkaline-manganese battery 1.5 V AA (4 pieces) Only to be used with Dialock DIN mortice locks. Mounting left/right, reversible. Spacer plate A spacer must be used if the distance between upper edge of face veneer and lock case is less than 8 mm. Mechanical emergency opening DT 100 door terminal sets must always be equipped with a single profile cylinder for optional mechanical emergency opening. When using the mechanical emergency opening, please note the information sheet for determining the single profile cylinder length (operating instructions can be found in our online shop "Easy link"). Battery change The type-specific discharge behaviour (considerable voltage drop at the end of the life time) of lithium batteries may cause that a low battery is indicated at the terminal only for a short period or not at all. DK ID 1815

61 DT 100 Door Terminal For interior doors Electronic Access Control SystemsDT 100 Door TerminalFor interior doorsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Determine lever handle and opening direction! Interior module " Exterior module (access control) The opening direction inwards or outwards must be selected with the mortice lock. Exterior module with lever handle pointing to the left, outwards opening, DIN left mortice lock $ Exterior module with lever handle pointing to the left, inwards opening, DIN right mortice lock % Exterior module with lever handle pointing to the right, inwards opening, DIN left mortice lock & Exterior module with lever handle pointing to the right, outwards opening, DIN right mortice lock External module with lever handle pointing to the left Lever handle design Satin stainless steel coloured 1 exterior module with R3 processor 1 R3 interior module 2 lever handle aperture parts Mounting material (e.g. spindle, threaded screw) 1 accessory bag Exterior module with lever handle pointing to the right 1 exterior module with R3 processor 1 R3 interior module 2 lever handle aperture parts Mounting material (e.g. spindle, threaded screw) 1 accessory bag ID 1815 DK Please order supplementary and optional components, e.g. lever handle aperture parts, mounting material for other door thicknesses and batteries, separately. Please specify the for backplates with visible punched hole: Internal backplate and/or external backplate Following cover plates must be used for new door terminals that replace old terminals: Cover plate, stainless steel, DTB replaced by DT Cover plate, stainless steel, TT replaced by DT Ordering product components DK

62 DT 100 Door Terminal For interior doors Electronic Access Control SystemsDT Door TerminalFor interior doorsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. DT 100 FH Door terminal set, for doors with requirements on fire resistance and smoke control Backplate exterior module with processor (access control) Backplate interior module Door terminal sets, for fire resistant and smoke control doors, backplates (cover hoods) made from ABS plastic, satin stainless steel coloured, stainless steel lever handle aperture parts Functionality Battery-operated, intelligent door terminal, touchless activation with Dialock key Red/green LEDs for indication of locking and unlocking Standard setting: Unlocking with Dialock key and automatic locking after 3 seconds The door can be opened without a key at any time from the inside. Mechanical emergency opening possible Electromotive locking, magnetic interactions cannot take place For service personnel: Indication of programming status and when battery change is required With real-time clock and audit trail of all processes Unlocking and locking with Dialock key (toggle mode) RFID interface in exterior module for programming Electric pushbutton on the inseide for "Do not disturb" and other functions Options (please order separately) Visible punched hole of cover hoods with mechanical emergency opening with single profile cylinder Other lever handle designs on request Macros for extension of functions available on request Technical data Technology Degree of protection Ambient temperature (operation) Relative humidity Life time of battery Memory Spindle Door thickness Mounting material Mifare Classic IP20 0 C to +55 C 0 95 % (not condensed) approx. 2 years or 22,000 locking and unlocking processes (with lithium batteries approx. 45,000 locking and unlocking processes) Event memory: up to 1,000 audit trail entries Key memory: up to 1,000 keys 9 mm mm For door thicknesses mm, if not ordered for other door thicknesses Electro-static discharge (ESD) High level security, tested to 20,000 V (standard 8,000 V) Voltage supply Notes for operation and installation Alkaline-manganese battery 1.5 V AA (4 pieces) Planning by Dialock specialists is required. DT 100 FH door terminal sets must be installed by Dialock specialists after approval by the door manufacturer. If the terminal is installed without this permission, the Fire and Smoke Control Certificate for the door will be invalidated. Only to be used in combination with Dialock DIN mortice locks for fire resistant and smoke control doors. Spacer plate A spacer must be used if the distance between upper edge of face veneer and lock case is less than 8 mm. Mechanical emergency opening DT 100 FH door terminal sets must always be equipped with a single profile cylinder for mechanical emergency opening. When using the mechanical emergency opening, please note the information sheet for determining the single profile cylinder length (operating instructions can be found in our online shop "Easy link"). Battery change The type-specific discharge behaviour (considerable voltage drop at the end of the life time) of lithium batteries may cause that a low battery is indicated at the terminal only for a short period or not at all. DK ID 1815

63 DT 100 Door Terminal For interior doors Electronic Access Control SystemsDT 100 Door TerminalFor interior doorsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Determine lever handle and opening direction! Interior module " Exterior module (access control) The opening direction inwards or outwards must be selected with the mortice lock. Exterior module with lever handle pointing to the left, outwards opening, DIN left mortice lock $ Exterior module with lever handle pointing to the left, inwards opening, DIN right mortice lock % Exterior module with lever handle pointing to the right, inwards opening, DIN left mortice lock & Exterior module with lever handle pointing to the right, outwards opening, DIN right mortice lock Exterior module with lever handle pointing to the left Lever handle design Satin stainless steel coloured 1 exterior module with R3 processor 1 R3 internal module 2 lever handle aperture parts Mounting material (e.g. spindle, threaded screw) 1 accessory bag Exterior module with lever handle pointing to the right 1 exterior module with R3 processor 1 R3 interior module 2 lever handle aperture parts Mounting material (e.g. spindle, threaded screw) 1 accessory bag ID 1815 DK Please order supplementary and optional components, e.g. lever handle aperture parts, mounting material for other door thicknesses and batteries, separately. Please specify the for backplates with visible punched hole: Internal backplate and/or external backplate Following cover hoods must be used for new door terminals that replace old terminals: Cover hood, stainless steel, DTB replaced by DT Cover hood, stainless steel, TT/TSE replaced by DT Ordering product components DK

64 DT 100 Door Terminal B Mortice locks DT 100 Door TerminalB locksplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Mortice lock For other backsets, finishes and more detailed information see section 6 For other striking plates and profile cylinders see section 4 Area of application: For rebated (forend 20 mm) or flush (forend 24 mm) wooden doors Type of locking: Prepared for profile cylinder Deadbolt: 2-turn, with self-locking action 1-turn Forend: Round Distance: 72 mm Standard: Connection dimensions in compliance with DIN 18251, part 1 For doors with standard requirements Area of application: Lever follower: The use on fire resistant and smoke control doors is not permitted 8 mm Backset Forend width Mounting Satin mm mm stainless steel Stainless steel, satin finish Steel, silver colour lacquered " Maximum security: With self-locking action $ Standard security: Grade 3 High level security: With deadlocking latchbolt and Quiet-Comfort " Mortice lock, with self-locking action DIN left DIN right * DIN left DIN right Mortice lock, with deadlocking latchbolt and Quiet-Comfort DIN left $ Mortice lock, grade 3 DIN right DIN left DIN right DIN left DIN right DIN left DIN right * Mortice lock can only be used in combination with flanged striking plate or For doors with requirements on fire resistance and smoke control & Maximum security: With self-locking action / Standard security: Grade 3 Lever follower: 9 mm Backset Forend width Mounting Satin mm mm stainless steel & Mortice lock, with self-locking action Stainless steel, satin finish DIN left / Mortice lock, grade 3 DIN right * DIN left DIN right DIN left DIN right * Mortice lock can only be used in combination with flanged striking plate or Steel, galvanized 24 DIN left DIN right Mortice lock DK 6.2 DK ID 1876

65 DT 100 Door Terminal C Lever handle aperture parts DT 100 Door TerminalC handle aperture partsplanning ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Lever handle aperture parts for doors with standard requirements Electronic Access Control SystemsDT 100 DT 210 Door TerminalC Lever partsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Lever handle aperture parts for fire resistant and smoke control doors Functionality: Area of application: Spindle: Material: Installation: For DT 100 and DT 210 and DT 600 door terminals with distance 72 mm For interior doors, the use on fire resistant and smoke control doors is not permitted 8 mm Stainless steel Grub screw (SW 3 T-handle screw driver) Functionality: Area of application: Spindle: Material: Installation: For DT 100 and DT 210 and DT 600 door terminals with distance 72 mm For interior doors, the use on fire resistant and smoke control doors is permitted 9 mm Stainless steel Grub screw (SW 3 T-handle screw driver) G-shape G-shape Finish Satin Note Not suitable for use with DT 600 FH door terminal. Finish Satin Packing: 1 or 5 pieces 2 lever handle aperture parts must be ordered for each door terminal set. PVD brass polished finish available on request. Packing: 1 or 5 pieces 2 lever handle aperture parts must be ordered for each door terminal set. PVD brass polished finish available on request ID 1815 DK U-shape Packing: 1 or 5 pieces Finish Satin lever handle aperture parts must be ordered for each door terminal set. PVD brass polished finish available on request. Spindle 8 mm DK SW3 T-handle screwdriver DK U-shape Note Not suitable for use with DT 600 FH door terminal. Packing: 1 or 5 pieces Finish Satin lever handle aperture parts must be ordered for each door terminal set. PVD brass polished finish available on request. Spindle 9 mm DK SW 3 T-handle screw driver DK

66 DT 100 Door Terminal D Profile cylinder for emergency opening DT 100 Door TerminalD Profile cylinder for emergency openingplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Startec Single cylinder DT 100 Door TerminalD Profile cylinder for emergency openingplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Startec Double cylinder Closure: Keyed to differ, S1 or GLS keyed alike Locking system: With 5 pin tumblers Standard: Certified in compliance with DIN and EN 1303:2005 Material: Cylinder housing: Brass Finish: Cylinder housing: Nickel plated Version: Follower adjustable to 12 positions Closure: Locking system: Standard: Material: Finish: Keyed to differ, S1 or GLS keyed alike With 5 pin tumblers Certified in compliance with DIN and EN 1303:2005 Cylinder housing: Brass Cylinder housing: Nickel plated Note No secured locking. 1 Single profile cylinder 3 Nickel plated steel keys 1 Fixing screw Keyed to differ Dim. A Dim. B Dim. C mm mm mm Keyed alike Dim. A Dim. B Dim. C S1 mm mm mm keyed alike GLS keyed alike Note No secured locking. 1 Double profile cylinder 3 Nickel plated steel keys 1 Fixing screw Keyed to differ Dim. A Dim. B Dim. C mm mm mm Keyed alike Dim. A Dim. B Dim. C S1 mm mm mm keyed alike GLS keyed alike DK ID 1815

67 DT 100 Door Terminal E Supplementary products DT 100 Door TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Mounting material for other door thicknesses Mounting material for doors with standard requirements Mounting material for doors with requirements on fire resistance and smoke control Spindle 8 mm > Area of application: The use on doors with requirements on fire resistance and smoke control is not permitted, for DT 100 R3 and DT 210 R2 exterior/interior module > Spindle: 8 mm > Material: Spindle and threaded screw: Steel > Finish: Spindle: Yellow galvanized, threaded screw: Galvanized > Installation: Spindle for suspending in coupling Spindle 9 mm > Area of application: The use on fire resistant and smoke control doors is permitted, for R3 exterior/interior module > Spindle: 9 mm > Material: Spindle and threaded screw: Steel > Finish: Spindle: Yellow galvanized, threaded screw: Galvanized > Installation: Spindle for suspending in coupling 1 Spindle 8 mm 4 Threaded screws, M4 2 Grub screws for lever handle aperture parts 1 Cover for emergency opening of the exterior module 1 Spindle 9 mm 4 Threaded screws M4 2 Grub screws for lever handle aperture parts ID 1852 DK Door thickness mm Spindle length mm Thread length mm Door thickness mm Spindle length mm Thread length mm Retaining ring pliers DK SW 3 T-handle screw driver DK

68 DT 100 Door Terminal E Supplementary products DT 100 Door TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Hinged glass door mounting adapter For doors with standard requirements Connecting cable For hinged glass door mounting adapter Functionality: For connecting exterior and interior module when using hinged glass door mounting adapters Version: Flat cable Connecting cable DT 100 Door TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. ACC Reset module Left hand mounted Functionality: Area of application: For glass thickness: Material: Finish/colour: For mounting DT 100 door terminal sets on hinged all-glass doors, locking by means of integrated closing spring latch mortice lock The use on doors with requirements on fire resistance and smoke control is not permitted mm when using the mounting material for DT 100 for interior doors mm Zinc alloy Satin stainless steel coloured Note Planning by Dialock specialist is required. ACC reset module Opening lever for battery compartment and SW 3 T-handle screw driver are also required. Please order separately. Drilling pattern Dimensions for DIN doors in mm Block work standard dim. Hinged glass door mounting adapter for doors with standard requirements Frame rebate dim. Standard glass dim. A x B 750 x x x x x x x x x x x x x x x x x x 2097 Mounting Left Right Please order hinged glass door mounting adapter, connecting cable ( ) and DT 100 door terminal set together. The DT 100 door terminal set is then supplied with pre-mounted connecting cable. Electronic Access Control SystemsG Service and maintenanceplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Cover plate For covering the edge of the drillings for TSE door terminals Area of application: Material: Finish: Dim. (L x W): TSE door terminal For covering the installation holes (with possible colour deviations and pressure marks) when replacing TSE door terminal with DT 100 door terminal Stainless steel Satin 310 x 72 mm Note Also suitable for the use on fire resistant and smoke control doors. 2 cover plates are required for 1 door. The minimum order quantity of cover plates is 20 pieces. Cover plate SW 3 T-handle screw driver DK Opening lever for battery compartment DK DK ID 1852

69 DT 100 Door Terminal F Processing and installation DT 100 Door TerminalF Processing and installationplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Drilling template F Processing and installationplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Drill bit Ø 8 mm Area of application: For drilling through hole for threaded screws on wooden doors Packing: 10 pieces F Processing and installationplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Drill bit Ø 16 mm HS steel twist drill bit Area of application: For drilling through hole for leading cables through wooden doors Twist drill F Processing and installationplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Router bit Ø 25 mm Area of application: Version: For through hole to lock nut on wooden doors With reducing sleeve and centring pin Router bit F Processing and installationplanning ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. SW3 T-handle screwdriver ID 1815 Functionality: For work preparation for mounting DT 100 door terminal sets on wooden doors Technical data DK Drilling dimensions 4 x Ø 8 mm continuous, 1 x Ø 16 mm continuous Installation Information on how to use the drilling template can be found in the installation instructions for the DT 100 door terminal sets. The installation instructions can be found in our online shop "Easy link". Drilling template Area of application: For mounting lever handle aperture parts Version: With integrated lateral drive for easy loosening and tightening of screw connections that are extremely tight or bonded Dim.: 3 x 100 mm F Processing and installationplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Locking ring pliers SW 3 T-handle screwdriver Area of application: For mounting the spindle Locking ring pliers

70 DT 100 Door Terminal G Service and maintenance DT 100 Door TerminalG Service and maintenanceplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Maintenance tool for battery compartment Functionality: Material: Colour: For emergency opening and battery change for DT 100 backplate external module, by attaching the maintenance tool to the backplate exterior module the cover can be unlocked and removed Plastic Anthracite 1 Maintenance tool 1 Hex key 3 mm Maintenance tool for battery compartment G Service and maintenanceplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Battery AA Operating temperature: 18 to +55 C with alkaline-manganese, 40 to +60 C with lithium Note The lithium battery has an up to 7 times longer life time than the alkaline-manganese battery. Note We recommend using these batteries only in order to guarantee smooth operation of the Dialock terminals. Alkaline-manganese battery 1.5 V AA (standard) Packing pieces 4 pieces required for one door terminal set. 10 or Lithium battery 1.5 V AA 2 or DK ID 1815

71 DT 400 Door Terminal, with or without Thumbturn Product overview DT 400 Door Terminal, with or without ThumbturnProduct overviewplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Ordering product components Standard Optional B C D E E G! +" Page DK / DK DK 6.6 DK DK DK DK DK DK Continue to step 3 $ DT 400 door terminal set with thumbturn DT 400 door terminal set without thumbturn Mortice lock with requirements on fire resistance and smoke control Striking plate Lever handle aperture parts Profile cylinder for emergency opening Escutcheon foil Spindle mounting set Mounting screws Spacer plate Batteries Programming and user keys! For guest room doors made from wood (with "Do not disturb" function) " For interior doors made from wood DK For external doors (outdoor version) $ For interior doors made from metal ID 1829 DK Information about processing and installation can be found in our online shop "Easy link" Sample order For interior hotel guest room doors (with thumbturn for "Do not disturb" function), wood, flush, 42 mm, DIN right, comfort function outwards opening doors, backset 55 mm, with blank escutcheon foil, battery-operated door terminal Door terminal set DT 400 door terminal set, with thumbturn, satin stainless steel C Lever handle aperture parts DK lever handle aperture parts, satin stainless steel DK B Mortise lock DIN right, for doors with comfort function outwards, satin stainless steel DK Flanged striking plate DK 6.8 D Short double cylinder, for mechanical emergency opening Keyed alike DK E Blank escutcheon foil Grey DK E Mounting screws for interior module and reader module For door thickness mm DK E Spindle mounting set For door thickness 42 mm DK G Batteries Alkaline-manganese battery 1.5 V AA DK Continue to step 3 Programming and user keys DK 10.28

72 DT 400 Door Terminal, with Thumbturn For interior or external doors (hotel guest room doors) Electronic Access Control SystemsDT Door Terminal, with ThumbturnFor interior or external doors (hotel guest room doors)planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. DT 400 FH Door terminal modules, for doors with requirements on fire resistance and smoke control Reader module as escutcheon with PC aperture (access control) Backplate interior module Door terminal modules, for fire resistant and smoke control doors, for interior guest room doors or external doors (outdoor version), plastic reader module, stainless steel backplate interior module. The DT 400 is equipped with Bluetooth Low Engergy which is used in hotel projects. The DT 400 can also be used for other projects if operated without Bluetooth Low Energy. Functionality Battery-operated, intelligent door terminal, touchless activation with Dialock key > White/red LEDs for indication of locking and unlocking > Door backplate interior module with thumbturn with which "Do not disturb" can be indicated on the reader module by a flashing signal > Door backplate interior module, with battery compartment > The door can be opened without a key at any time from the inside > Electronic and mechanical emergency opening possible > For service personnel: Indication of programming status and when battery change is required > With real-time clock and audit trail of all processes, including electronic and mechanical emergency openings > Infrared interface for programming Options (please order separately) > Escutcheon foil for reader module with PC aperture or as blank cover > Macros for extension of functions available on request Technical Data Technology Degree of protection Ambient temperature (operation) Relative humidity Life time of battery Spindle Door thickness Electrostatic discharge (ESD) Voltage supply Mifare Classic IP20 Outdoor version (reader module) IP45 0 C to +55 C Outdoor version (reader module) 20 C to +60 C 0 95 % (not condensed) Approx locking and unlocking processes (with lithium battery approx. 70,000 locking and unlocking processes) 9 mm mm Panic exit device Tested to EN 179 High level security, tested to 20,000 V (standard 8,000 V) Alkaline manganese battery 1.5 V AA (4 pieces) Panic exit device approval In compliance with EN 179 Note BLE = Bluetooth Low Energy Door terminals that are equipped with BLE can also be opened via mobile phone with suitable app. Notes for operation and installation Planning by Dialock specialists is required. DT 400 FH door terminal modules must be installed by Dialock specialists after approval by the door manufacturer. If the terminal is installed without this permission, the Fire and Smoke Control Certificate for the door will be invalidated. Can only be used in combination with the DIN mortice lock for DT 400. The comfort function is determined with the mortice lock. Mechanical emergency opening DT 400 FH door terminal modules must always be equipped with a single profile cylinder or short profile cylinder for mechanical emergency opening. When using the mechanical emergency opening, please note the information sheet for determining the single profile cylinder length or short profile cylinder length (operating instructions can be found in our online shop "Easy link"). Outdoor version Only the reader module is suitable for outdoor use. Please note the installation specifications for this version. The outdoor version must be approved by Häfele for the respective installation site. Installation sites with special conditions, e.g. saline environment, are not possible. Please contact your responsible Häfele employee when ordering the product. Battery change: The type-specific discharge behaviour (considerable voltage drop at the end of the life time) of lithium batteries may cause that a low battery is indicated at the terminal only for a short period or not at all. We recommend changing the batteries before the winter months with the outdoor version. DK ID 1829

73 DT 400 Door Terminal, with Thumbturn For interior or external doors (hotel guest room doors) DT 400 Door Terminal, with ThumbturnFor interior or external doors (hotel guest room doors)planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Determine lever handle and opening direction! Interior module " Exterior module (access control) The opening direction inwards or outwards must be selected with the mortice lock. Exterior module, outwards opening, DIN left mortice lock $ Exterior module, inwards opening, DIN right mortice lock % Exterior module, inwards opening, DIN left mortice lock & Exterior module, outwards opening, DIN right mortice lock Area of application Satin Polished brass coloured (PVD) 1 R3 reader module as reader unit with escutcheon 1 R3 interior module with BLE For interior guest room doors with BLE For external guest room doors with BLE (outdoor version) Installation ID 1829 DK Please observe following dimensions when installing as fully operational unit: A External length, relevant for profile cylinder selection B Internal length, relevant for profile cylinder selection, must not exceed dim. B1 C Door thickness outside, relevant for spindle and spacer plate selection D Door thickness inside, relevant for spindle selection E Total door thickness, relevant for mounting screws selection The following components must also be ordered for a fully operational unit: B 1 mortice lock for DT 400 C 2 lever handle aperture parts D 1 profile cylinder for mechanical emergency opening E 1 escutcheon foil E 1 spindle F 1 set of mounting screws for interior module and reader module F 4 batteries Ordering product components DK

74 DT 400 Door Terminal, without Thumbturn For interior doors Electronic Access Control SystemsDT Door Terminal, without ThumbturnFor interior doorsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. DT 400 FH Door terminal modules, for doors with requirements on fire resistance and smoke control Reader module as escutcheon with PC aperture (access control) Backplate interior module Door terminal modules, for fire resistant and smoke control doors in offices and conference rooms, plastic reader module, stainless steel backplate interior module. Functionality Battery-operated, intelligent door terminal, touchless activation with Dialock key > Design identical to DT 400 FH for interior guest room doors, but without thumbturn for "Do not disturb" indication > White/red LEDs for indication of locking and unlocking > Door backplate interior module, with battery compartment > The door can be opened without a key at any time from the inside > Electronic and mechanical emergency opening possible > For service personnel: Indication of programming status and when battery change is required > With real-time clock and audit trail of all processes, including electronic and mechanical emergency openings > Infrared interface for programming Options (please order separately) > Escutcheon foil for reader module with PC aperture or as blank cover > Macros for extension of functions available on request Technical Data Technology Degree of protection Ambient temperature (operation) Relative humidity Life time of battery Spindle Door thickness Electrostatic discharge (ESD) Voltage supply Mifare Classic IP20 0 C to +55 C 0 95 % (not condensed) Approx. 50,000 locking and unlocking processes (with lithium battery approx. 70,000 locking and unlocking processes) 9 mm mm High level security, tested to 20,000 V (standard 8,000 V) Alkaline manganese battery 1.5 V AA (4 pieces) Panic exit device approval In compliance with EN 179 Note BLE = Bluetooth Low Energy Door terminals that are equipped with BLE can also be opened via mobile phone with suitable app. Notes for operation and installation Planning by Dialock specialists is required. DT 400 FH door terminal modules must be installed by Dialock specialists after approval by the door manufacturer. If the terminal is installed without this permission, the Fire and Smoke Control Certificate for the door will be invalidated. Can only be used in combination with the DIN mortice lock for DT 400. The comfort function is determined with the mortice lock. Mechanical emergency opening DT 400 FH door terminal modules must always be equipped with a single profile cylinder or short profile cylinder for mechanical emergency opening. When using the mechanical emergency opening, please note the information sheet for determining the single profile cylinder length or short profile cylinder length (operating instructions can be found in our online shop "Easy link"). Battery change: The type-specific discharge behaviour (considerable voltage drop at the end of the life time) of lithium batteries may cause that a low battery is indicated at the terminal only for a short period or not at all. DK ID 1829

75 DT 400 Door Terminal, without Thumbturn For interior doors DT 400 Door Terminal, without ThumbturnFor interior doorsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Determine lever handle and opening direction! Interior module " Exterior module (access control) The opening direction inwards or outwards must be selected with the mortice lock. Exterior module, outwards opening, DIN left mortice lock $ Exterior module, inwards opening, DIN right mortice lock % Exterior module, inwards opening, DIN left mortice lock & Exterior module, outwards opening, DIN right mortice lock Area of application Satin Polished brass coloured (PVD) 1 R3 reader module as reader unit with escutcheon 1 R3 interior module with BLE For interior guest room doors with BLE For external guest room doors with BLE (outdoor version) Installation ID 1829 DK Please observe following dimensions when installing as fully operational unit: A External length, relevant for profile cylinder selection B Internal length, relevant for profile cylinder selection, must not exceed dim. B1 C Door thickness outside, relevant for spindle and spacer plate selection D Door thickness inside, relevant for spindle selection E Total door thickness, relevant for mounting screws selection The following components must also be ordered for a fully operational unit: B 1 mortice lock for DT 400 C 2 lever handle aperture parts D 1 profile cylinder for mechanical emergency opening E 1 escutcheon foil E 1 spindle F 1 set of mounting screws for interior module and reader module F 4 batteries Ordering product components DK

76 DT 400 Door Terminal B Mortice locks DT 400 Door TerminalB locksplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Mortice lock, grade 3, for doors with requirements on fire resistance and smoke control > Area of application: For rebated doors (forend 20 mm) or flush doors (forend 24 mm) > Version: With self-locking action and feedback, with comfort function, with emergency opening function, with key trap function C, quality assurance by control symbol and certified in compliance with EN > Type of locking: Prepared for profile cylinder > Deadbolt: 1-turn > Forend: Round > Lever follower: 9 mm > Distance: 72 mm > Material: Forend: Stainless steel, latchbolt and lock case: Steel, lever follower: Malleable cast Routing height for lock case >175 mm (feedback height 8 mm) Definition of the comfort function A door can be inwards or outwards opening irrespective of the mounting. P The small handle symbol on the forend specifies the lock side with comfort function. Drawing shows DIN left mortice lock with comfort function inwards opening doors. Emergency opening function Door is always locked (self-locking action). Emergency opening function is monitored (feedback) > Opening of door from inside: The latchbolt is retracted by activating the lever handle. > Opening of door from outside: Turn the key in the single profile cylinder in opening direction as far as it will go, hold and simultaneously activate lever. Key trap function C The key can be removed only in locked position. The emergency opening function is restored after locking. Forend width mm Mounting Backset A 55 mm Combination with electric strikes not possible. Mortice lock with Swiss round cylinder aperture available on request. 20 DIN L, comfort function outwards opening DIN L, comfort function inwards opening DIN R, comfort function outwards opening DIN R, comfort function inwards opening DIN L, comfort function outwards opening Backset A 60 mm DIN L, comfort function inwards opening DIN R, comfort function outwards opening DIN R, comfort function inwards opening DIN L, comfort function outwards opening DIN L, comfort function inwards opening DIN R, comfort function outwards opening DIN R, comfort function inwards opening DIN L, comfort function outwards opening Backset A 65 mm DIN L, comfort function inwards opening DIN R, comfort function outwards opening DIN R, comfort function inwards opening DIN L, comfort function outwards opening DIN L, comfort function inwards opening DIN R, comfort function outwards opening DIN R, comfort function inwards opening DIN L, comfort function outwards opening Backset A 80 mm DIN L, comfort function inwards opening DIN R, comfort function outwards opening DIN R, comfort function inwards opening DIN L, comfort function outwards opening DIN L, comfort function inwards opening DIN R, comfort function outwards opening DIN R, comfort function inwards opening DIN L, comfort function outwards opening DIN L, comfort function inwards opening DIN R, comfort function outwards opening DIN R, comfort function inwards opening DK ID 1829

77 DT 400 Door Terminal B Mortice locks DT 400 Door TerminalB Mortice locksplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Planning 1. Observe rebate gap of >2 mm and >7 mm. 2. Please note: > Space requirement for latchbolt throw min. 20 mm > Combination with electric strike is not possible. 3. Observe the lock pocket dimensions. Dimension! in drawing is greater than with normal mortice locks due to the cable outlet. Door drilling dimensions Lock case routing dimensions Installation Please note: > Never drill through door with inserted lock! The drill bit must not damage the lock. > Do not knock the spindle into the square spindle aperture using a hammer. The lock requires a split spindle. > Remove all processing residues (chipping) from the lock pocket ID 1829 DK For detailed installation and operating instructions please refer to the respective in our online shop "Easy link.

78 DT 400 Door Terminal C Lever handle aperture parts DT 400 Door TerminalC handle aperture partsplanning ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Lever handle aperture parts, for doors with requirements on fire resistance and smoke control > Area of application: For interior doors > Spindle: 9 mm, split > Material: Stainless steel > Installation: Grub screw with SW 3 T-handle screw driver Note DT 400 is a tested product approved for doors with requirements on fire resistance and smoke control in compliance with DIN Only the lever handle aperture parts shown here have appropriate approval. The Fire and Smoke Certificate in compliance with DIN will be invalidated if the lever handle aperture parts vary in shape, design, function and by manufacturer. Testing and approval of other lever handle aperture parts (if suitable) possible on request. Outdoor use only after written approval by Häfele. * Shape and dimensions of polished brass coloured (PVD) models similar to illustration. 1 lever handle aperture part for interior module 1 lever handle aperture part with rose Model U For doors with requirements in compliance with EN 179 Spindle 9 mm, split DK SW 3 T-handle screw driver DK Model G Finish Satin Polished brass coloured (PVD)* Finish Satin Polished brass coloured (PVD)* DK ID 1829

79 DT 400 Door Terminal D Profile cylinder for emergency opening DT 400 Door TerminalD cylinder for emergency openingplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Profile cylinder > Type of locking: Short double cylinder: Keyed to differ or keyed alike, single cylinder: S1 keyed alike > Material: Cylinder housing: Brass, key: Steel > Finish: Cylinder housing and key: Nickel plated Note The short double cylinder is only used in combination with DT 400 door terminal. A detailed product description and other keyed alike key changes can be found on the following page. Short double cylinder Startec single cylinder Installation options for profile cylinder Comfort function Please note different dim. C with comfort function inwards and outwards opening. Reader module with blank escutcheon foil Reader module with PC escutcheon foil Technical data Dim. A mm Dim. B mm Reader module with blank escutcheon foil Reader module with PC escutcheon foil ID 1829 DK Short double cylinder Dim. C mm Dim. C mm Dim. C mm Dim. C mm Comfort function for inwards opening doors Comfort function for outwards opening doors Comfort function for inwards opening doors 1 short double cylinder or single cylinder 3 keys 1 fixing screw Comfort function for outwards opening doors C + 6 mm = max. A C mm = max. A C mm = min. A C + 7 mm = min. A Dim. C is measured by Dialock specialist when using short double cylinder. Single cylinder , Compensation with spacer plate A spacer plate 3 mm is required for thin doors: Reader module with spacer plate 3 mm Reader module with blank escutcheon foil: Dim. C <26 mm Reader module with PC escutcheon foil: Dim. C <17 mm Type of locking Dim. A mm Short double cylinder Keyed to differ Keyed alike Startec single cylinder S1 keyed alike Spacer plate DK Short double cylinder (product description) DK

80 DT 400 Door Terminal D Profile cylinder for emergency opening DT 400 Door TerminalD Profile cylinder for emergency openingplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Short double cylinder Keyed to differ 1 short double cylinder 3 short keys 1 fixing screw M5 x 80 mm Packing: 1 or 10 pieces Short double cylinder with keys Keyed alike with key 1 short double cylinder 3 short keys 1 fixing screw M5 x 80 mm > Type of locking: Keyed to differ or keyed alike > Locking system: With 3 pin tumblers > Material: Cylinder housing and key: Brass > Finish: Cylinder housing and key: Nickel plated > Length L: 43.4 mm > Dim. A: 21.7 mm > Dim. B: 21.7 mm Note No secured locking, locking system and extension of double cylinder possible. The keys are shorter to suit the short design of the double cylinder. Therefore the keys are not suitable for other profile cylinders. The short double cylinder is not suitable for fire resistant or smoke control doors! Suitable are all single or double cylinders from 27.5 mm in this catalogue. Installation options for profile cylinder Reader module with blank escutcheon foil Reader module with PC escutcheon foil Dim. C is measured by Dialock specialist when using short double cylinder. Keyed alike without key 1 short double cylinder 1 fixing screw M5 x 80 mm Please order suitable keys for cylinder separately. Key 1 short key Short double cylinder with keys Short double cylinder without key Key change Key change Key DK ID 1829

81 DT 400 Door Terminal E Supplementary products DT 400 Door TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Escutcheon foil for reader module > Area of application: Cover foil for sticking onto reader module > Material: Plastic > Colour: Grey or white Without aperture (blank) Apertures Colour PC Grey White None Grey White Packing: 25 pieces Customized design of the escutcheon foil is available on request (from an order quantity of 50 pieces). With PC aperture (profile cylinder) DT 400 Door TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Spacer plate for reader module 3 > Area of application: For compensation with thin door panels > Thickness: 3.0 mm > Material: Stainless steel q53± ID 1829 Compensation with spacer plate Reader module with spacer plate 3 mm Technical Data Profile cylinder DK Short double cylinder Single cylinder A spacer plate 3 mm is required for thin doors: Reader module with blank escutcheon foil: Dim. C <26 mm Reader module with PC escutcheon foil: Dim. C <17 mm Reader module with blank escutcheon foil Comfort function Please note different dim. C with comfort function inwards and outwards opening. Reader module with PC escutcheon foil Dim. C mm Dim. C mm Dim. C mm Dim. C mm Comfort function inwards opening Comfort function outwards opening Comfort function inwards opening Dim. C is measured by Dialock specialist when using short double cylinder Finish Comfort function outwards opening Satin Polished Polished brass coloured (PVD)

82 DT 400 Door Terminal E Supplementary products DT 400 Door TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Spindle DT 400 R2 mounting set DT 400 Door TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Mounting screws > Functionality: For connecting the lever handle aperture parts with the mortice lock > Area of application: Grub screw for securing lever handle aperture parts, chipboard screws for fixing the mortice lock > Spindle: 9 mm, split > Material: Steel > Finish: Galvanized > Functionality: For mounting the modules on the door > Area of application: For lever handle aperture part, interior module and reader module > Material: Steel > Finish: Galvanized Installation The installation instructions can be found in our online shop. Please note the door thickness (dim. E) of DT 400 door terminal from mm. Installation The installation instructions can be found in our online shop. DK 2017, HDE-en, 01/17; Dimensional data not binding. We reserve the right to alter specifications without notice. 1 spindle 9 mm, split 1 stainless steel bolt Ø 4 mm 2 cylinder screws M 3.5 x 8 mm 2 grub screws 2 chipboard screws 4.5 x 40 mm 1 seal for external lever handle (terminal) Dim. E Dim. C Dim. D mm mm mm Version 1: 50 80, version 2: Version 1: 30 45, version 2: Version 1: 23 38, version 2: Torque screwdriver is required for mounting. Please order separately. 4 screws M4 with locking paint for lever handle aperture part and interior module Dim. E mm DK ID 1886

83 DT 400 Door Terminal G Service and maintenance DT 400 Door TerminalG Service and maintenanceplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Battery AA > Operating temperature: 18 to +55 C with alkaline-manganese, 40 to +60 C with lithium Note The lithium battery has an up to 7 times longer life time than the alkaline-manganese battery. Note We recommend using these batteries only in order to guarantee smooth operation of the Dialock terminals. Alkaline-manganese battery 1.5 V AA (standard) Packing pieces 4 pieces required for one door terminal set. 10 or Lithium battery 1.5 V AA 2 or Electronic Access Control SystemsG Service and maintenanceplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Cover plate For covering the edge of the drillings for TSE door terminals ID 1829 Note TSE door terminal > Area of application: For covering the installation holes (with possible colour deviations and pressure marks) when replacing TSE door terminals with DT 400, DT 700 or DT 510 door terminals > Material: Stainless steel > Finish: Satin > Dim. (L x W): 310 x 72 mm Also suitable for the use on fire resistant and smoke control doors. 2 cover plates are required for 1 door. Not suitable for door terminals with Bluetooth Low Energy. DT 210 Door TerminalE Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. "Do not disturb" thumbturn Cover plate > Functionality: For retrofitting with matching terminal colour for DT 210 or DT 400 door terminal without thumbturn, indicates "Do not disturb" on the exterior module by a flashing signal > Material: Stainless steel Finish/colour DK Satin Polished Polished brass coloured

84 DT 400 Door Terminal F Processing and installation DT 400 Door TerminalF Processing and installationplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Drilling jig F Processing and installationplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Router bit Ø 25 mm > Area of application: For through hole to lock nut on wooden doors > Version: With reducing sleeve and centring pin Router bit F Processing and installationplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Router bit Ø 32 mm > Area of application: For widening the cable drilling on the outside through to the lock pocket (only with audit trail of emergency opening) > Version: With centring pin Router bit F Processing and installationplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. PZ router bit guide > Area of application: For extending the PC aperture for leading cable through for reader rosette of DT 400 door terminals > Functionality: For work preparation for DT 210 and DT 400 door terminals on wooden doors Technical Data Drilling dim. Installation Information on how to use the drilling jig can be found in the installation instructions for the DT 210 and DT 400 door terminals. The installation instructions can be found in our online shop "Easylink". F Processing and installationplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Drill bit Ø 8 mm Packing: 10 pieces 4 X Ø 8 mm continuous, 1 x Ø 13 mm continuous, 1 x Ø 8 mm centring drilling for router bit (only with audit trail of emergency opening), 1 x Ø 25 mm recess on the outside at least 7 mm deep, 1 x Ø 32 mm recess on the outside through to the lock pocket (only with audit trail of emergency opening) Drilling jig > Area of application: For drilling through hole for threaded screws on wooden doors HS steel twist drill bit Please order router bit Ø 25 mm, , separately. F Processing and installationplanning ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. SW 3 T-handle screw driver PZ router bit guide > Area of application: For mounting lever handle aperture parts > Version: With integrated lateral drive for easy loosening and tightening of screw connections that are extremely tight or bonded > Dim.: 3 x 100 mm SW 3 T-handle screw driver DK ID 1888

85 DT 400 Door Terminal F Processing and installation DT 400 Door TerminalF Processing and installationplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Screwdriver 1.4 Nm PH2 blade > Area of application: Required for installation of DT400 mounting set, for controlled screwing with defined torque of 1.4 Nm in combination with Wiha torque replacement blade 4 mm > Version: Blade: High-quality chrome-molybdenumvanadium steel, hardened, matt chrome plated. Wiha ChromTop blade tip guarantees maximum dimensional accuracy. Colour code: Dark blue > Standard: DIN ISO blade tip > Accuracy: ±6% Screwdriver 1.4 Nm with PH2 blade PH2 replacement blade PH2 replacement blade DK 1829 DK PH2 mounting aid > Area of application: For controlled screw fixing of DT 400 mounting set. Counterpart for screwdriver. PH2 mounting aid

86 Häfele Dialock DT 600 Door Terminal Product overview Häfele Dialock DT 600 Door TerminalProduct overviewnew products and systemsnew products and systemsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Ordering product components Standard Optional B C E D G F!! For interior doors made from wood Page DK DK DK DK DK DK DK Continue to step 3 DT 600 door terminal set, without lever handle aperture parts, distance 72 mm, with lever follower 8 mm Mortice lock Lever handle aperture parts Mounting material for other door thicknesses Profile cylinder Batteries Accessories for processing and installation Programming and user keys DK DK 2015, HDE-en, 07/15; Dimensional data not binding. We reserve the right to alter specifications without notice. Information about processing and installation can be found in our online shop. Sample order For wooden interior door, flush 40 mm, distance 72 mm, lever follower 8 mm, backset 55 mm, inwards opening, lever handle pointing to the left, DIN left, battery-operated door terminal Door terminal set DT 600 door terminal set, with lever handle pointing to the left C Lever handle aperture parts DK x lever handle aperture part, U-shape DK B Mortice lock With deadlocking latchbolt and Quiet-Comfort DK D Profile cylinder for mechanical emergency opening Double cylinder, keyed to differ DK E Mounting material Mounting material for door thickness mm DK F Accessories for processing and installation DK G Maintenance tool DK x 1.5 V AA alkaline manganese battery DK Continue to step 3 Programming and user keys DK ID 1882 DK

87 Häfele Dialock DT 600 Door Terminal For interior and external doors DK 2015, HDE-en, 07/15; Electronic Access Control SystemsHäfele DT 600 Door TerminalFor interior and external doors / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Häfele Dialock DT 600 Door terminal module, for doors with standard requirements Backplate exterior module with processor (access control) Internal backplate ID 1882 DK Door terminal module for interior doors, elegant and slim door terminal (Phönix Design), satin stainless steel, operating unit: Plastic, polished black Functionality Battery-operated, intelligent door terminal, touchless activation with Dialock key > Blue/red LEDs for indication of locking and unlocking > Standard setting: Unlocking with Dialock key and automatic locking after 3 seconds > The door can be opened without a key at any time from the inside. > Mechanical emergency opening possible > For service personnel: Indication of programming status and when battery change is required > Unlocking and locking with Dialock key (toggle mode) > With real-time clock and audit trail of all processes > Infrared interface for programming > Backplate exterior module with battery compartment Options (please order separately) > Colour coordinated lever handle aperture parts can be found in the Dialock range (special finishes on request) > Macro for extension of functions available on request Technical Data Degree of protection Ambient temperature (operation) Relative humidity Battery service life Spindle Distance Door thickness Electrostatic discharge (ESD) Voltage supply IP40 0 C to +55 C 0 95 % (not condensed) Approx. 30,000 locking and unlocking processes 8 mm 72 mm mm Notes for operation and installation High level security, tested to V (standard 8000 V) Alkaline manganese battery 1.5 V AA (2 pieces) For use in combination with Dialock DIN mortice locks Mechanical emergency opening When using the optional mechanical emergency opening, please note the information sheet for determining the double profile cylinder length (operating instructions can be found in our online shop). Installation on full panel door is possible with 8 mm mortice lock/spindle from backset 55 mm. Outdoor version Only the backplate exterior module is suitable for outdoor use. More information can be found in our online shop. The outdoor version must be approved by Häfele for the respective installation site. Installation sites with special conditions, e.g. saline environment, are not possible. Please contact your responsible Häfele employee when ordering the product. Battery change: The type-specific discharge behaviour (considerable voltage drop at the end of the life time) of lithium batteries may cause that a low battery is indicated at the terminal only for a short period or not at all. We recommend changing the batteries before the winter months with the outdoor version. DK 2015, HDE-en, 07/15; Dimensional data not binding. We reserve the right to alter specifications without notice.

88 Häfele Dialock DT 600 Door Terminal For interior and external doors Electronic Access Control SystemsHäfele Dialock DT 600 Door TerminalFor interior external doors / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Determine lever handle and opening direction! Interior module " Exterior module (access control) The opening direction inwards or outwards must be selected with the mortice lock. Exterior module with lever handle pointing to the left, outwards opening, DIN left mortice lock $ Exterior module with lever handle pointing to the left, inwards opening, DIN right mortice lock % Exterior module with lever handle pointing to the right, inwards opening, DIN left mortice lock & Exterior module with lever handle pointing to the right, outwards opening, DIN right mortice lock Exterior module with lever handle pointing to the left Suitable for 1 exterior module with processor (without lever handle aperture part) 1 internal backplate (without lever handle aperture part) 1 battery cover Interior doors External doors (outdoor version) Exterior module with lever handle pointing to the right 1 exterior module with processor (without lever handle aperture part) 1 internal backplate (without lever handle aperture part) 1 battery cover Interior doors External doors (outdoor version) DK 2015, HDE-en, 07/15; Dimensional data not binding. We reserve the right to alter specifications without notice. Please order supplementary and optional components, e.g. lever handle aperture parts, mounting material and batteries, separately. A Profile cylinder external length A 1 Door thickness outside A 2 Backplate exterior module thickness = 23 mm B Profile cylinder internal length B 1 Door thickness inside B 2 Backplate inside thickness = 10 mm A = A mm B = B mm Dim. A 1 and B 1 depend on the selected door Ordering product components DK DK ID 1882

89 Häfele Dialock DT 600 Door Terminal B Mortice locks Häfele Dialock DT 600 Door TerminalB locksplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Mortice lock, profile cylinder With deadlocking latchbolt and Quiet-Comfort Door LocksFor DT 100 and DT 210 door terminalsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Mortice lock, profile cylinder Grade 3 Dim. in brackets apply to forend width 20 mm Dim. in brackets apply to forend width 20 mm ID 1882 > Area of application: For rebated (forend 20 mm) or flush (forend 24 mm) wooden doors, deadlocking latchbolt prevents the latchbolt from being pushed back, e.g. by a credit card > Material: Forend: Stainless steel, latchbolt and deadbolt: Zinc alloy, lever follower: Brass, deadlocking latchbolt and lock case: Steel > Type of locking: Prepared for profile cylinder > Deadbolt: 2-turn > Version: With key action, with Quiet-Comfort-Equipment for quiet closing of the door > Forend: Round > Lever follower: 8 mm > Distance B: 72 mm > Standard: Connection dimensions in compliance with DIN 18251, part 1 Forend width mm DK Backset A 55 mm Mounting Satin stainless steel 20 DIN left DIN right DIN left Backset A 60 mm DIN right DIN left DIN right DIN left Backset A 65 mm DIN right DIN left DIN right DIN left Backset A 80 mm DIN right DIN left DIN right DIN left DIN right > Area of application: For rebated (forend 20 mm) or flush (forend 24 mm) wooden doors > Material: Forend: Stainless steel, brass and steel, latchbolt and deadbolt: Zinc alloy, lever follower: Zinc alloy/steel, lock case: Steel > Type of locking: Prepared for profile cylinder > Deadbolt: 2-turn > Version: With key action > Forend: Round > Lever follower: 8 mm > Distance B: 72 mm > Standard: Certified in compliance with DIN 18251, part 1, grade 3 and EN 12209:2003 Forend width mm Mounting Backset A 55 mm Satin stainless steel Polished brass Steel, silver colour lacquered 20 DIN left DIN right DIN left Backset A 60 mm DIN right DIN left DIN right DIN left Backset A 65 mm DIN right DIN left DIN right DIN left DIN right Striking plates DK 6.6 DK 2015, HDE-en, 07/15; Dimensional data not binding. We reserve the right to alter specifications without notice.

90 Häfele Dialock DT 600 Door Terminal C Lever handle aperture parts Häfele Dialock DT 600 Door TerminalC Lever aperture partsplanning ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Lever handle aperture parts for doors with standard requirements > Functionality: For DT 100 and DT 210 and DT 600 door terminals with distance 72 mm > Area of application: For interior doors, the use on fire resistant and smoke control doors is not permitted > Spindle: 8 mm > Material: Stainless steel > Installation: With grub screw (SW 3 T-handle screw driver) G-shape U-shape Finish Satin Finish Satin lever handle aperture parts must be ordered for each door terminal set. Brass polished PVD finish available on request 2 lever handle aperture parts must be ordered for each door terminal set. Brass polished PVD finish available on request DK 2015, HDE-en, 07/15; Dimensional data not binding. We reserve the right to alter specifications without notice. DK ID 1882

91 ID 1882 DK

92 Häfele Dialock DT 600 FH Door Terminal Product overview Häfele Dialock DT 600 FH Door TerminalProduct overviewnew products and systemsnew products and systemsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Ordering product components Standard Optional B E D G F!! For narrow frame doors Page DK DK DK DK DK DK Continue to step 3 DT 600 FH door terminal set, with lever handle aperture parts, distance 92 mm, with lever follower 9 mm Narrow frame mortice lock suitable for the selected frame profile Mounting material for other door thicknesses Profile cylinder Batteries Accessories for processing and installation Programming and user keys DK Information about processing and installation can be found in our online shop. DK 2015, HDE-en, 07/15; Dimensional data not binding. We reserve the right to alter specifications without notice. Sample order For interior narrow frame door with requirements on fire resistance, frame thickness 42 mm, distance 92 mm, lever follower 9 mm, backset 40 mm, inwards opening, lever handle pointing to the left, DIN right, battery-operated door terminal Door terminal set DT 600 FH door terminal set, with lever handle pointing to the left C Lever handle aperture parts DK Supplied B Mortice lock BKS series 18xx or 19xx (please order separately) D Profile cylinder for mechanical emergency opening Double cylinder, keyed to differ DK E Mounting material Mounting material for door thickness mm DK F Accessories for processing and installation DK G Maintenance tool DK x 1.5 V AA alkaline manganese battery DK Continue to step 3 Programming and user keys DK DK ID 1882

93 Häfele Dialock DT 600 FH Door Terminal For narrow frame doors Electronic Access Control SystemsHäfele DT 600 FH Door TerminalFor narrow frame doors / Planning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Dialock DT 600 FH Door terminal module, for doors with requirements on fire resistance/smoke control Backplate exterior module with processor (access control) Interior half set ID 1882 DK Door terminal module for fire resistant and smoke control doors on narrow frame doors, elegant and slim door terminal (Phönix Design), satin stainless steel, operating unit: Plastic, polished black Functionality Battery-operated, intelligent door terminal, touchless activation with Dialock key > Blue/red LEDs for indication of locking and unlocking > Standard setting: Unlocking with Dialock key and automatic locking after 3 seconds > The door can be opened without a key at any time from the inside. > Mechanical emergency opening possible > For service personnel: Indication of programming status and when battery change is required > Unlocking and locking with Dialock key (toggle mode) > With real-time clock and audit trail of all processes > Infrared interface for programming > Backplate exterior module with battery compartment Options (please order separately) > Macro for extension of functions available on request Technical Data Degree of protection IP40 Ambient temperature (operation) 0 C to +55 C Relative humidity Battery service life Spindle Distance Frame thickness Electrostatic discharge (ESD) Voltage supply 0 95 % (not condensed) Approx. 30,000 locking and unlocking processes 9 mm 72 or 92 mm mm High level security, tested to V (standard 8000 V) Alkaline manganese battery 1.5 V AA (2 pieces) Panic exit device Tested according to EN 179/1125 Notes on operation and installation Installation on narrow frame doors with narrow frame mortice lock from backset 35 mm. Planning by Dialock specialists is required. DT 600 FH door terminal sets must be approved and installed by the door manufacturer. If the terminal is installed without this permission, the Fire and Smoke Control Certificate for the door will be invalidated. When installing as panic exit device in compliance with EN 179/1125, it is mandatory to observe the certificate of the approved mortice locks. Mechanical emergency opening DT 600 FH door terminal sets must always be equipped with a double profile cylinder for mechanical emergency opening. When using the mechanical emergency opening, please note the information sheet for determining the double profile cylinder length (operating instructions can be found in our online shop). Outdoor version Only the backplate exterior module is suitable for outdoor use. More information can be found in our online shop. The outdoor version must be approved by Häfele for the respective installation site. Installation sites with special conditions, e.g. saline environment, are not possible. Please contact your responsible Häfele employee when ordering the product. Battery change: The type-specific discharge behaviour (considerable voltage drop at the end of the life time) of lithium batteries may cause that a low battery is indicated at the terminal only for a short period or not at all. We recommend changing the batteries before the winter months with the outdoor version. DK 2015, HDE-en, 07/15; Dimensional data not binding. We reserve the right to alter specifications without notice.

94 Häfele Dialock DT 600 FH Door Terminal For narrow frame doors Electronic Access Control SystemsHäfele Dialock DT 600 FH Door TerminalFor narrow frame doors / Planning ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Determine lever handle and opening direction! Interior module " Exterior module (access control) The opening direction inwards or outwards must be selected with the mortice lock. Exterior module with lever handle pointing to the left, outwards opening, DIN left mortice lock $ Exterior module with lever handle pointing to the left, inwards opening, DIN right mortice lock % Exterior module with lever handle pointing to the right, inwards opening, DIN left mortice lock & Exterior module with lever handle pointing to the right, outwards opening, DIN right mortice lock Exterior module with lever handle pointing to the left Distance B Suitable for 1 exterior module with processor and lever handle aperture part 1 battery cover 1 interior half set with lever handle aperture part 92 mm Interior doors mm External doors (outdoor version) mm Interior doors mm External doors (outdoor version) Exterior module with lever handle pointing to the left 1 exterior module with processor and lever handle aperture part 1 battery cover 1 interior half set with lever handle aperture part 92 mm Interior doors mm External doors (outdoor version) mm Interior doors mm External doors (outdoor version) DK 2015, HDE-en, 07/15; Dimensional data not binding. We reserve the right to alter specifications without notice. Please order supplementary and optional components, e.g. double profile cylinder, mounting material and batteries, separately. A Profile cylinder external length A 1 Narrow frame thickness outside A 2 Backplate exterior module thickness = 23 mm B Profile cylinder internal length B 1 Narrow frame thickness inside B 2 Backplate inside thickness = 10 mm A = A mm B = B mm Dim. A 1 and B 1 depend on the selected narrow frame profile Ordering product components DK DK ID 1882

95 Häfele Dialock DT 600 FH Door Terminal B Mortice locks Häfele Dialock DT 600 FH Door TerminalB Mortice locksplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Narrow frame mortice lock With alternating function E DT 600 Door Terminal Mortice lock accessoriesplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Striking plate For narrow frame mortice lock Flat forend U-shaped forend ID 1882 DK > Area of application: For single narrow frame doors > Material: Forend: Stainless steel, latchbolt, lever follower and lock case: Steel > Type of locking: Prepared for profile cylinder > Deadbolt: 1-turn > Version: With self-locking action > Forend: Flat square or U-shaped square > Lever follower: 9 mm > Distance: 92 mm > Standard: In compliance with EN 179 and EN 1125 Forend Mounting Satin stainless steel Backset A 35 mm Flat, 24 mm, square U-shaped, 24 mm, square Backset A 40 mm Flat, 24 mm, square U-shaped, 24 mm, square Backset A 45 mm Flat, 24 mm, square U-shaped, 24 mm, square For DIN left and DIN right hand use For DIN left and DIN right hand use For DIN left and DIN right hand use Other narrow frame mortice locks for e.g. individual narrow frame profiles, functions and versions from the BKS series 18xx and 19xx available on request. Striking plate Flanged striking plate U-shaped striking plate > Area of application: For narrow frame doors > Material: Stainless steel > Finish: Satin Mounting Square Round Striking plate For DIN left and DIN right hand use Flanged striking plate DIN left DIN right U-shaped striking plate For DIN left and DIN right hand use DK 2015, HDE-en, 07/15; Dimensional data not binding. We reserve the right to alter specifications without notice.

96 Häfele Dialock DT 600 FH Door Terminal B Mortice locks Häfele Dialock DT 600 FH Door TerminalB Mortice locksplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. B-2326 Mortice lock For single doors Fire resistance and smoke control For fire resistant and smoke control doors in compliance with DIN 4102 and fire resistant doors in compliance with EN > Area of application: For single, rebated or flush doors made from wood or steel, inward/outward opening doors (adjustable), prepared for profile cylinder > Material: Forend: Stainless steel, latchbolt and deadbolt: Steel, lock case: Steel > Finish: Forend: Satin, latchbolt and deadbolt: Nickel plated, lock case: Galvanized > Deadbolt: 1 turn > Version: With key action > Forend: 20 or 24 mm > Lever follower: Continuous 9 mm Standard Activation type Class EN 179: B A B/D EN 1125:2008 Touchbar B A B (note: The EN 179:2008 and EN 1125:2008 standards are only met in conjunction with jointly tested fitting sets.) Forend width mm Backset A 65 mm Mounting Push bar B B B 20 DIN left DIN right DIN left/din right (reversible) DK ID 1882

97 Häfele Dialock DT 600 FH Door Terminal B Mortice locks Häfele Dialock DT 600 FH Door TerminalB locksplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. B-2116 Mortice lock For single doors Fire resistance and smoke control For fire resistant and smoke control doors in compliance with DIN 4102 and fire resistant doors in compliance with EN ID 1882 (note: The EN 179:2008 and EN 1125:2008 standards are only met in conjunction with jointly tested fitting sets.) Forend width mm DK > Area of application: For single, rebated or flush doors made from wood or steel, inward/outward opening doors (adjustable), prepared for profile cylinder > Material: Forend: Stainless steel, latchbolt: Steel, lock case: Steel > Finish: Forend: Satin, latchbolt: Nickel plated, lock case: Galvanized > Deadbolt: 1-turn > Version: With key action, latchbolt is pre-locked by 20 mm automatically when the door is being closed. > Forend: 20 or 24 mm > Lever follower: Continuous 9 mm Standard Activation type Class EN 179: B A B/D EN 1125:2008 Touchbar B A B Backset A 65 mm Mounting Push bar B B B 20 DIN left DIN right DIN left/din right (reversible)

98 Häfele Dialock DT 600 Door Terminal D Profile cylinder, E supplementary products Häfele Dialock DT 600 Door TerminalD Profile cylinder, E supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Startec Double cylinder E Supplementary productsplanning and ConstructionDimensional data not binding. We reserve the right to alter specifications without notice. Mounting material For doors with standard requirements > Area of application: For doors with standard requirements, the use on fire resistant and smoke control doors is not permitted > Spindle: 8 mm > Material: Spindle and threaded screw: Steel > Finish: Spindle: Yellow galvanized, threaded screw: Galvanized 1 spindle 3 threaded screws, M5 2 grub screws for lever handle aperture parts > Type of locking: Keyed to differ, S1 or GLS keyed alike > Locking system: With 5 pin tumblers > Standard: Certified in compliance with DIN and EN 1303:2005 > Material: Cylinder housing: Brass > Finish: Cylinder housing: Nickel plated Note No secured locking. 1 double profile cylinder 3 nickel plated steel keys 1 fixing screw Keyed to differ Dim. A mm Dim. B mm Keyed alike Dim. C mm Dim. A mm Dim. B mm Dim. C mm S1 keyed alike GLS keyed alike Other cylinder dimensions DK 6.36 Door thickness mm Spindle x 80 mm x 80 mm x 90 mm x 100 mm x 110 mm x 120 mm For doors with requirements on fire resistance/smoke control > Spindle: 9 mm > Material: Spindle and threaded screw: Steel > Finish: Spindle: Yellow galvanized, threaded screw: Galvanized 1 spindle, 9 mm 3 threaded screws, M5 1 grub screw for lever handle aperture part Door thickness mm Spindle x 80 mm x 80 mm x 90 mm x 100 mm x 110 mm x 120 mm DK ID 1882

Dialock Wall Terminals For outdoor and indoor use

Dialock Wall Terminals For outdoor and indoor use Dialock Wall Terminals For outdoor and indoor use Dialock electronic locking systemdialock TerminalsFor outdoor and indoor useprices Availability OrderingPlanning, Construction WT Wall terminal set With

More information

Wireless Access Controlled Door Solution

Wireless Access Controlled Door Solution Wireless Access Controlled Door Solution Solution family: Interior Door Solution Solution group: Single-Wood-Self Closing- Access Control Description The ASSA ABLOY Belgium solution for high security interior

More information

2.46. Locking and Security Information. Emergency exit device EN 179. Panic exit device EN New products and systems:

2.46. Locking and Security Information. Emergency exit device EN 179. Panic exit device EN New products and systems: Information Emergency exit device EN 179 The standard cover devices to be used in emergency situations if people are familiar with the emergency exit and whose hardware. In this situation a panic is most

More information

AMADEO i-lock Your innovative key card system for hotels

AMADEO i-lock Your innovative key card system for hotels AMADEO i-lock Your innovative key card system for hotels TECHNICAL DATA SHEET AMADEO i-lock A PERFECT FIT FOR ANY HOTEL Easy upgrade, fits on existing mortise locks without door rework Flexible design,

More information

Locks and Catches Information

Locks and Catches Information Information SYMO 3000 is the worldwide unique furniture locking system from Häfele. Without tools and time-consuming installation, it provides maximum flexibility at minimum expenditure and effort. The

More information

Locking and Security Information

Locking and Security Information Information Profile cylinder Locking cylinders are catergorized according to a) Front view b) Side view Profile cylinder Double cylinder Single cylinder Thumbturn cylinder The definition of important components

More information

Locks and Catches Electronic Locking System

Locks and Catches Electronic Locking System Master key locking systems Master key locking systems simplify the organization and management of large projects with many different locks. Apart from the individual keys locking their assigned objects,

More information

3200 Series Cylindrical Lock

3200 Series Cylindrical Lock 3200 Series Cylindrical Lock 53mm 64mm RP01 Rebated part to suit cylindrical lock Mechanism Heavy gauge cold rolled steel, zinc plated and dichromated for rust resistance. Material Roses are stainless

More information

Locking and Security Information

Locking and Security Information Master key system Comprehensive building situation requires locking systems. The scope and the complexity of these systems is depend on the size of the building, the number of doors and the user function

More information

RIM LOCKS. An ASSA ABLOY Group brand ASSA ABLOY

RIM LOCKS. An ASSA ABLOY Group brand ASSA ABLOY RIM LOCKS An ASSA ABLOY Group brand ASSA ABLOY What Type of Door? A comprehensive range of locks for both exterior and interior glass panelled or solid timber doors. T G available for outward opening doors.

More information

Locks. Call from anywhere in Canada - Locking Systems - Overview...493

Locks. Call from anywhere in Canada -   Locking Systems - Overview...493 Locking Systems - Overview...493 Lever Bit/Skeleton Keys and Accessories...494 496 Symo 3000 Locking System...497 511 Cylinder Module System...512 529 Cam Locks...516, 530, 537, 541, 543 Deadbolt Locks...514

More information

Door Hinges Concealed Hinges

Door Hinges Concealed Hinges Concealed mortise hinge For installation in wall recesses For flush wooden or metal doors Suitable for DIN left hand and DIN right hand Certified for fire resistant and smoke control doors in compliance

More information

StarTec Collection. Innovative and Functional Door Hardware

StarTec Collection. Innovative and Functional Door Hardware StarTec Collection 2009 Innovative and Functional Door Hardware DT Lite Electronic Locking System Mifare technology Fast opening process DND function (Do Not Disturb) Suitable for use on apartment doors

More information

2010 Product Line Catalog

2010 Product Line Catalog 2010 Product Line Catalog Electronic Access Control Locksets Now Part of 1 Electronic access control locksets With thousands of units in operation worldwide, IEI locksets are recognized for the highest

More information

The Essentials Architectural Hardware. The Essentials Architectural Hardware. Electronic Locking Systems - DT Lite (Residential Version)

The Essentials Architectural Hardware. The Essentials Architectural Hardware. Electronic Locking Systems - DT Lite (Residential Version) Electronic Locking Systems - DT Lite (Residential Version) Contemporary Door Knobsets DT Lite is an Electronic Identifi cation and Locking System for secure and simple access. The access cards are easy

More information

TRADITIONAL DOOR LOCK

TRADITIONAL DOOR LOCK TRADITIONAL DOOR LOCK The ERA Traditional Door Lock has been designed to replace most existing front door locks, providing added security to new exterior and interior doors. The lock is suitable for left

More information

DOOR TECHNOLOGY ORDER CATALOG SECTION GU-SECURY Automatic European Profile Cylinder Operated Locks

DOOR TECHNOLOGY ORDER CATALOG SECTION GU-SECURY Automatic European Profile Cylinder Operated Locks DOOR TECHNOLOGY ORDER CATALOG SECTION 03.12 GU-SECURY Automatic European Profile Cylinder Operated Locks Table of Contents 03.12 SECURY Automatic European Profile Cylinder Operated Door Locks SECURY Automatic

More information

Hinges and Flap Fittings Furniture Hinges

Hinges and Flap Fittings Furniture Hinges Butt hinge Material: Steel Length: 50 mm Flange thickness: 1.5 mm Barrel Ø: 8 mm Crank A, straight Ø Gap1 mm Mounting Nickel plated matt Left 1.08.717 Right 1.08.708 Brass plated Left 1.08.511 Right 1.08.502

More information

DOOR TECHNOLOGY ORDER CATALOG SECTION GU-SECURY Automatic Smart Access Controlled

DOOR TECHNOLOGY ORDER CATALOG SECTION GU-SECURY Automatic Smart Access Controlled DOOR TECHNOLOGY ORDER CATALOG SECTION 03.5 GU-SECURY Automatic Smart Access Controlled Table of Contents 03.5 GU-SECURY Automatic Smart Access Controlled GU-SECURY Automatic Key-operated Door Lock...03.5.3

More information

Mechanical Locking Shortform

Mechanical Locking Shortform Section Header Architectural Ironmongery Catalogue Mechanical Locking Shortform (01782) 834818 1 Symbols This symbol indicates that the product is CE marked under EN12209. CE marking is compulsory for

More information

LS-SERIES Features LS-1 LS-2 & LS-2P LS-2P

LS-SERIES Features LS-1 LS-2 & LS-2P LS-2P Access Control Locksets Access Control Solutions for a Changing World LS-SERIES Features Non-volatile eeprom memory allows in-shop programming One non-handed unit for both indoor and outdoor applications

More information

Aries Smart. Rev.1.0_UK January 11

Aries Smart. Rev.1.0_UK January 11 Aries Smart Rev.1.0_UK 2016 January 11 1 Aries Electronic Trim Stand-alone battery operated access control device Cost effective solution for door access management No wiring required Narrow Profile (38

More information

HAWA-JUNIOR 80 XINNIX POCKET SLIDING DOOR SYSTEM

HAWA-JUNIOR 80 XINNIX POCKET SLIDING DOOR SYSTEM SLIDING DOOR FITTINGS DIRECTORY / APRIL 2014 POCKET SLIDING INTERIOR DOOR SYSTEMS HAWA-JUNIOR 80 XINNIX POCKET SLIDING DOOR SYSTEM High quality straight sliding door gear for residential or commercial

More information

CONTENTS. Sliding Door Fittings Information. Sliding door fittings from Häfele. Sliding door application for Classic 40-J/80-J/120-J

CONTENTS. Sliding Door Fittings Information. Sliding door fittings from Häfele. Sliding door application for Classic 40-J/80-J/120-J Information CONTENTS Sliding door fittings from Häfele...3 Soft and self closing systems from Häfele...4 Sliding door fitting Classic 40-P/80-P/120-P SLIDO... Sliding door fitting Classic 40-P/80-P/120-P

More information

39 46,5 A 9,5. 2 x 3V CR2 Lithium batteries for each electronic knob. With battery change tool set

39 46,5 A 9,5. 2 x 3V CR2 Lithium batteries for each electronic knob. With battery change tool set 46,5 A I 35,5 Knob cylinder, single-sided 1) Housing length (I/O) 60-120 mm Inside 30-60 mm Outside 30-60 mm 46,5 A I 46,5 Knob cylinder, double-sided 1) Housing length (I/O) 60-120 mm Housing length (I/O)

More information

Non-handed, pre-assembled for left hand door installation easily changed in the field

Non-handed, pre-assembled for left hand door installation easily changed in the field PIN Access Electronic Pushbutton Lock 100 Access Codes Cylindrical Features Access Control: No Wires: Locking Device Options: Number of Codes: Handing: Programming: Key Override (Optional): Operation Modes:

More information

CK4400 Series. Standard Duty Cylindrical Knob Locksets

CK4400 Series. Standard Duty Cylindrical Knob Locksets Series Standard Duty Cylindrical Knob Locksets Applications Applications An outstanding combination of value and performance. Ideal for quality residential and light commercial buildings, such as: Fine

More information

P r e l i m i n a r y. Digital cylinder with 17 mm Euro profile. 1435MID/options. Kaba digital cylinder. Digital cylinder with 17 mm Euro profile

P r e l i m i n a r y. Digital cylinder with 17 mm Euro profile. 1435MID/options. Kaba digital cylinder. Digital cylinder with 17 mm Euro profile Digital cylinder with 17 mm Euro profile Kaba digital cylinder Description The digital locking cylinder is fitted with a Mifare reader antenna on the knob. The security-relevant electronics are installed

More information

E-Plex 5700 Series E-PLEX

E-Plex 5700 Series E-PLEX PIN/PROX or Dual Credential Electronic Pushbutton Lock 3,000 Access Codes 30,000 Audit Events Access Schedules ANSI/BHMA Grade-1 Certified Features Access Control: No Wires: Locking Device Options: Number

More information

002 Digital DX Deadlatch

002 Digital DX Deadlatch 002 Digital DX Deadlatch Description The Lockwood Digital DX Locksets provide a mechanical method of keyless entry and are designed to control access into commercial areas, especially when frequent combination

More information

Version C > (recommended max. width) Version D > (recommended max. width) Version E

Version C > (recommended max. width) Version D > (recommended max. width) Version E Classic 40-L to 120-L Sliding door fitting from Area of application: For 1-leaf and 2-leaf sliding doors : Tempered safety glass For glass thickness: Tempered safety glass: 8 and 10 Adjustment facility:

More information

DOOR TECHNOLOGY ORDER CATALOG SECTION GU-SECURY Automatic Door Lock & Lever Handle

DOOR TECHNOLOGY ORDER CATALOG SECTION GU-SECURY Automatic Door Lock & Lever Handle DOOR TECHNOLOGY ORDER CATALOG SECTION 03.2 GU-SECURY Automatic Door Lock & Lever Handle Table of Contents 03.2 GU-SECURY Automatic Door Lock & Lever Handle GU-SECURY Automatic Automatic Door Lock...03.2.5

More information

Electronic access organisation

Electronic access organisation 2 Electronic access organisation 37 Overview 25 1015 Page 48 f. 25 1016 Page 50 f. 25 1023 Page 52 f. 25 1035 Page 54 f. 25 1045 Page 56 f. 25 1070 Page 58 f. 25 1076 Page 60 f. 25 1078 Page 62 f. 38 FSB

More information

Secured Door w/ Electric Lock - Solenoid

Secured Door w/ Electric Lock - Solenoid Secured Door w/ Electric Lock - Solenoid Solution family: Interior Door solution Solution group: Single-Wood-Self Closing- Access Control Description The ASSA ABLOY Belgium solution for secured interior

More information

Lock Functions Single Cylinder Deadbolt Functions

Lock Functions Single Cylinder Deadbolt Functions Lock Functions Single Cylinder Deadbolt Functions L9453 F20 LV9453 Entrance Lock Latchbolt retracted by knob/lever from either side unless outside is locked by 20º rotation of thumbturn. Deadbolt thrown

More information

Key in Lever and Key in Knob Locksets. Locksets Key in Knob and Key in Lever

Key in Lever and Key in Knob Locksets. Locksets Key in Knob and Key in Lever Key in Lever and Key in Knob Locksets Locksets Key in Knob and Key in Lever Key in Knob and Key in Lever Locksets Overview Lockwood offers a range of Key in Knob and Key in Lever locksets for all architectural,

More information

4500/4600/4300 SERIES KEY IN LEVER LOCKSETS. ainsborough now offers a broad selection of key in lever lockset

4500/4600/4300 SERIES KEY IN LEVER LOCKSETS. ainsborough now offers a broad selection of key in lever lockset 4500/4600/4300 SERIES ainsborough now offers a broad selection of key in lever lockset G designs, from the 4500 and 4600 Series to the newly released 4300 Series range. The 4500 and 4600 Series key in

More information

Borglocks. Product Guide. Tel controlling access

Borglocks. Product Guide.  Tel controlling access Borglocks controlling access Product Guide www.borglocks.com Tel. 0800 44 88 377 About Us & Contents The Borg range of mechanical and electronic access controls are the product of over 17 years of market

More information

E-Plex 5700 Series E-PLEX

E-Plex 5700 Series E-PLEX PIN/PROX or Dual Credential Electronic Pushbutton Lock 3,000 Access Codes 30,000 Audit Events Access Schedules ANSI/BHMA Grade-1 Certified Features Access Control: No Wires: Locking Device Options: Number

More information

Window Fittings Sliding/Folding Fittings

Window Fittings Sliding/Folding Fittings Folding window fitting Fold 35 Features For timber door frames For 2- to 6-leaf folding doors Floating suites possible Full corrosion resistant construction, ideal for coastal applications Concealed channel

More information

Locking and Security Information

Locking and Security Information system Where two or more individual cylinders are not only locked by an individual key, but also by superior keys, a so-called master key system is created. The application of master key systems reaches

More information

Technical Manual Part 1 Assembly and Operating Instruction for all PegaSys Components

Technical Manual Part 1 Assembly and Operating Instruction for all PegaSys Components PegaSys Intelligent Access Control System Technical Manual Part 1 Assembly and Operating Instruction for all PegaSys Components The documentation has been written for persons that install and commission

More information

Electric locks ELECTRIC LOCKS

Electric locks ELECTRIC LOCKS 6 Electric locks ELECTRIC LOCKS Introduction ELECTRIC LOCKS ABLOY are without doubt, the world s premier manufacturer of electric locks. Our extensive range includes both motor and solenoid locks providing

More information

Access Control Electric Locking. Security Systems. Reader Technology

Access Control Electric Locking. Security Systems. Reader Technology Electric Locking - the ASSA solution What can access control achieve for you? It can secure a reduction in crime and the protection of your premises and assets, through the monitoring and restriction of

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 0711016 Page 1 INSTALLATION INSTRUCTIONS ELECTRONIC DEADBOLT WITH KEYPAD latch 2-3/8 Your latch is now set 2-3/8 (60mm) backset latch 2-3/4 2-3/4" (70mm) 2-3/8" (60mm) Cylindrical cover Extension plate

More information

SpeedSec BP Automatic Barrier System

SpeedSec BP Automatic Barrier System SpeedSec BP Automatic Barrier System Power Requirements 110/220V. 60/50Hz. AC (%±10) 24V.DC -At standby ~10W. During operation ~39W. (Single-sided) -At standby ~20W. During operation ~78W. (Central unit)

More information

Door, Hatch & Interior Fittings

Door, Hatch & Interior Fittings Sea Blue Security Locks NEW 10 Year Guarantee Sea Blue Security locks have been developed in the lock capital of England to withstand both corrosion and physical attack. Heavy steel full casings are used

More information

SECURITY LOCKS WITH ELECTRONIC LOCK MECHANISM

SECURITY LOCKS WITH ELECTRONIC LOCK MECHANISM SAFEGUARDING YOUR SECURITY SECURITY LOCKS WITH ELECTRONIC LOCK MECHANISM Security lock with electronic key Transforms a normal lock into a security lock with a coded electronic key. Security system applicable

More information

DL300 FINGERPRINT LOCK

DL300 FINGERPRINT LOCK DL300 FINGERPRINT LOCK USER MANUAL Please read this manual carefully before operation. Please keep this manual for later reference. Intelligent Biometric Controls, LLC. Tel: (513) 336-9292 Fax: (513) 336-0626

More information

Sliding Door Fittings, Roller Shutters

Sliding Door Fittings, Roller Shutters Sliding Door Fittings, Roller Shutters Contents Sliding Timber Door Fittings Finetta Flatfront Foldfront Mobilus Classic Sliding door system Automatic sliding door system Planomix Planofit Straightening

More information

Light/Medium-Duty Knob Locksets. CK4700 Series

Light/Medium-Duty Knob Locksets. CK4700 Series Light/Medium-Duty Knob Locksets CK4700 Series Applications Quality The CK4700 series is a Grade 2 light/medium-duty knob lockset which provides an outstanding combination of value and performance. It is

More information

Assa Classic. An ASSA ABLOY Group company

Assa Classic. An ASSA ABLOY Group company Assa Classic Assa - The Security Company Assa AB manufactures and develops locks and security systems for the world s public building market. New regulations and local standards require us to continguously

More information

Locks. Product range:

Locks. Product range: Locks Product range: Coin Locks Combination Locks Espagnolette Locks Keys Lay on Locks Locks for Metal Furniture Lock Strikers Mortise Locks Padlock Handle Pedestal Locks Removable Cylinder Locks Rim Locks

More information

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1 INSTALLATION GUIDE InBio Pro Series Access Control Panels Date: Dec., 2015 Version: 1.1 2 3 What s in the Box CONTENT 2 Screws & Anchors 2 Screwdriver 4 Diode Contents What s in the Box...2 Optional accessories...4

More information

PRODUCT BROCHURE Welcome to access, Welcome to SALTO Systems.

PRODUCT BROCHURE Welcome to access, Welcome to SALTO Systems. PRODUCT BROCHURE SALTO Systems unique new integrated wire-free escutcheons and cylinders can be used for a wide range of access control applications. This is the first RFID system that can be integrated

More information

Fire control. Electromagnetic fire Door Retainers. Available Models

Fire control. Electromagnetic fire Door Retainers. Available Models 2 Fire control Electromagnetic fire Door Retainers - Operating Voltage: 24Vdc or 240Vac - Holding Force: 55kg or 140kg - Tested and certified to EN 1155 and CE marked - Surface mounts to standard BS wiring

More information

Hands-Free entry Electronic door lock for residence

Hands-Free entry Electronic door lock for residence 0 Hands-Free entry Electronic door lock for residence Electronic door lock with integrated RFID reader with 3 ways entry. (Hands-Free, Non-touch(proximity), Mechanical key) For cosmetic reasons, the mechanical

More information

Key in Lever and Key in Knob Locksets

Key in Lever and Key in Knob Locksets Key in Lever and Key in Knob Locksets Locksets Key in Knob and Key in Lever Key in Knob and Key in Lever Locksets Overview Lockwood offers a range of Key in Knob and Key in Lever locksets for all architectural,

More information

Wadsworth Security Products

Wadsworth Security Products WADSWORTH SECURITY PRODUCTS Wadsworth Security Products The Best System Masterkeying is a way of coding a system of locks to give authorised personnel access to a series of locks to which they have authority

More information

Installation Guide(s)

Installation Guide(s) FCC Part 15 Transmitter Certification Test Report FCC ID: SPI-4XXKPMR FCC Rule Part: 15.09 ACS Report Number: 05-070-15C Manufacturer: Single Access Lock Inc. Model: 4XXKP/MR Installation Guide(s) 5015

More information

Installation & Programming Manual. Quick Reference

Installation & Programming Manual. Quick Reference Installation & Programming Manual Getting Started Prepare door, per additional instructions (included) before installing unit. IMPORTANT: Read instructions completely before beginning installation. Refer

More information

Hinges and Flap Fittings

Hinges and Flap Fittings Hinges and Flap Fittings Contents Concealed Hinges Duomatic Premium Concealed hinge Duomatic Concealed hinge Metallamat Concealed hinge Metalla Concealed hinge Push Latch for push to open hinge Metalla

More information

TECTUS Concealed Hinges

TECTUS Concealed Hinges Concealed Hinges index TE 240 3d up to 40 kg (88 lbs) 6 TE 340 3d up to 80 kg (176 lbs) 7 TE 525 3d up to 120 kg (264 lbs) 8 TE 526 3d up to 120 kg (264 lbs) 9 TE 527 3d up to 120 kg (264 lbs) 10 TE 540

More information

Smart Door Lock. Manufacturer's Installation Guide

Smart Door Lock. Manufacturer's Installation Guide Smart Door Lock Manufacturer's Installation Guide Package Contents 1. Quick Start Guide 2. Installation Instructions 3. Door Marker 4. Touchpad (Outside Escutcheon) 5. Latch (Inside Escutcheon) 6. Inside

More information

www.hafeleindia.com www.hafeleindia.com STILE DOOR HARDWARE BY HAFELE An office that is too noisy can be unnerving. With the popularity of predominantly open commercial spaces, there is a growing need

More information

SAFETY

SAFETY 24 SAFETY SECURITY ELECTROMAGNETS IDEAL FOR EMERGENCY EXITS AND CONDOMINIUM ENTRY DOORS SILENT AND RESISTANT HOLDING FORCE FROM 150 TO 1500 KG CAN BE APPLIED ON PRE-EXISTING DOORS 25 26 SAFETY www.opera-italy.com

More information

Glass door fittings Glass door hinges Glass door knobs Inset handles for glass doors Glass door handle Glass door stop

Glass door fittings Glass door hinges Glass door knobs Inset handles for glass doors Glass door handle Glass door stop 4c 39 404 406 40 409 409 Glass door fittings Glass door hinges Glass door knobs Inset handles for glass doors Glass door handle Glass door stop Overview 13 4224 Pages 39, 399 13 422 Page 404 13 4220 Pages

More information

Hinges and Flap Fittings Application Matrix

Hinges and Flap Fittings Application Matrix Application Matrix Model Opening angle Application Page Soft close Opening Integrated Optional With handle Without handle Screws Without tools Duomatic Concealed hinges Premium 110 Standard.11 / / / /

More information

SERIES 500 TECHNICAL DETAILS THURSDAY, JANUARY 24, 2008

SERIES 500 TECHNICAL DETAILS THURSDAY, JANUARY 24, 2008 SERIES 500 TECHNICAL DETAILS 1. Table of Contents 2. Overall Specifications 3. Door Overall Dimensions 4. Door Construction 5. Total Preassembled Dimensions 6. Overall Frame Dimensions 7. Frame Profile

More information

PUSH BAR EXIT DEVICES CROSS BAR EXIT DEVICES NARROW STILE EXIT DEVICES FEATURING LCWD STRIKES... 20

PUSH BAR EXIT DEVICES CROSS BAR EXIT DEVICES NARROW STILE EXIT DEVICES FEATURING LCWD STRIKES... 20 Exit Devices Section TABLE OF CONTENTS EXIT DEVICES PUSH BAR EXIT DEVICES N1500 Heavy Duty Rim Exit Device N1550 Rim Exit Device... 6 N1650 Fire Rated Heavy Duty Exit Device N1700(F) Vertical Rod Heavy

More information

1010A DEADLOCK DOOR MOUNTED FOR SMALL SWINGING DOORS APPLICATION: FUNCTION: CRAFTMASTER HARDWARE CO., INC

1010A DEADLOCK DOOR MOUNTED FOR SMALL SWINGING DOORS APPLICATION: FUNCTION: CRAFTMASTER HARDWARE CO., INC DOOR MOUNTED FOR SMALL Maximum security. 1010A-1: KEYED ONE SIDE 1010A-2: KEYED BOTH SIDES For small swinging doors on access panels, plumbing chases, control cabinets, etc. FUNCTION: Key activated locking

More information

3580 Series Cylinder Mortice Locks. Keeler Hardware. telephone

3580 Series Cylinder Mortice Locks. Keeler Hardware. telephone 3580 Series Cylinder Mortice Locks ASSA ABLOY, the global leader in door opening solutions Contents 3580 General Information 1-2 3582 Short Backset Vestibule Locks 4-6 3584 Short Backset Combination Locks

More information

Hardware Solution for Doors

Hardware Solution for Doors Hardware Solution for Doors Sv Panic Locks Series 200 Panic Strike Box Series 200 Standard and Panic Locks Series 200 Design-Line Panic Bar Handle Variosafe-Lock Barrel Hinges, Aluminium Door Hinges Wilh.

More information

SECTION D. Bi-Folding Window and Door Hardware

SECTION D. Bi-Folding Window and Door Hardware SECTION D Bi-Folding Window and Door Hardware D SECTION D Bi-Folding Window and Door Hardware D7 D9 D11 D13 D15 D17 Twin Bolt Locksets Millton Bi-fold 2-Point Locksets Pinnacle Bi-fold Locksets Flush

More information

ELECTRONIC LOCKS AND BARS BLOCK POWERED ELECTRIC LOCKS

ELECTRONIC LOCKS AND BARS BLOCK POWERED ELECTRIC LOCKS 49 ELECTRONIC LOCKS AND BARS BLOCK POWERED ELECTRIC LOCKS 49 49.M01/M21 Powered electronic locks Characteristics Lock for double cylinders Variation in centre distance:.../28 -.../37 BATTERY or MAINS operated

More information

Cylinders. Hinges. Bolts

Cylinders. Hinges. Bolts BOLOTA 304 BOLOTA 304 THE COMPANY PRODUCT RANGES SERVICE SAMPLES INDEX Lever Handles Escutcheons Turn and Release Sets Pull Handles Push Plates and Signage Locks and Latches Cylinders Door Closers Hinges

More information

7KC SERIES: MEDIUM DUTY CYLINDRICAL LOCKS LEVERS. 7KC Series. Medium Duty Cylindrical Locks Levers. BEST: Setting the Standard for Security

7KC SERIES: MEDIUM DUTY CYLINDRICAL LOCKS LEVERS. 7KC Series. Medium Duty Cylindrical Locks Levers. BEST: Setting the Standard for Security 7KC SERIES: MEDIUM DUTY CYLINDRICAL LOCKS LEVERS 7KC Series Medium Duty Cylindrical Locks Levers BEST: Setting the Standard for Security TABLE OF CONTENTS Features...2 Specifications...2 How To Order...3

More information

HAWA CONCEPTA & FOLDING CONCEPTA

HAWA CONCEPTA & FOLDING CONCEPTA 2018 www.hafele.com.au HAWA CONCEPTA & FOLDING CONCEPTA NEW GENERATION III New thinking for new rooms Hawa and EKU have become Hawa Sliding Solutions. As a global technology and market leader, we discover

More information

For further assistance, call

For further assistance, call DOOR HANDLS - VARIOUS Inside: - Alpha Standard Door Handle - Scrolled Door Handle - Traditional Styled Door Handle - Lock Lock Security Door Handle - Yale Conexis L1 Smart Lock Door Handle - Push Button

More information

Mechanical Entrance Locksets

Mechanical Entrance Locksets Mechanical Entrance Locksets We take the worry out of protecting what s valuable to you. Lockwood: no worries www.lockweb.com.au Contents Nexion Mechanical Velocity Entrance Locksets Entrance Locksets

More information

INTECH Micro 2300-RTD6

INTECH Micro 2300-RTD6 INTECH Micro 2300-RTD6 6 Channel RTD Input Station Overview. The Intech Micro 2300 Series is a system of modular I/O Remote Stations, that add an even lower cost option to Intech s already extensive intelligent

More information

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies General information Actuator controls AC 01.2 for controlling multi-turn actuators of the SA/SAR type range and part-turn actuators of the SQ/SQR.2 type range. Power supply Standard voltages AC: 3-phase

More information

ALPRO ALPRO. The hinge system for aluminium and steel doors

ALPRO ALPRO. The hinge system for aluminium and steel doors The hinge system for aluminium and steel doors 2 INDEX The hinge system for aluminium and steel doors 5 6 7 Aluminium door hinge Aluminium and stainless steel for inward-opening doors for inward-opening

More information

Overview of types. Technical data

Overview of types. Technical data Technical data sheet 6..S+NVFT24-MFT-E Globe valves, 2-way, with flange PN 16, actuator with emergency control function for closed hot water systems up to 150 C in district heating applications approved

More information

Our passion for quality and service means we are the only brand in our market sector which offers:

Our passion for quality and service means we are the only brand in our market sector which offers: Our passion for quality and service means we are the only brand in our market sector which offers: The Complete Package to the door parts, instructions, templates everything except the tools. The Codelocks

More information

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys... TABLE OF CONTENTS A Adjustable Angle Bracket (2941/2942)... 6 Angle Brackets (2950 Series)... 9 Armature Mounting Plates (2950 Series)...7-8 C Coordinator Mounting Bracket (2950 Series)... 8 Concealed

More information

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys... TABLE OF CONTENTS A Adjustable Angle Bracket (2941/2942)... 6 Angle Brackets (2950 Series)... 9 Armature Mounting Plates (2950 Series)...7-8 C Coordinator Mounting Bracket (2950 Series)... 8 Concealed

More information

Electric Mortice Locks

Electric Mortice Locks Electric Mortice Locks Strikes Contents 3570 Series Electric Mortice Lock 2 3570/3670 Series Proximity Mortice Lock & Furniture 8 3570 Series Room Guard Electric Mortice Locks & Controller 12 3580 Series

More information

DIAMOND DOOR PRODUCTS TECHNICAL DETAILS MARCH 2010

DIAMOND DOOR PRODUCTS TECHNICAL DETAILS MARCH 2010 DIAMOND DOOR PRODUCTS TECHNICAL DETAILS 1. Table of Contents 2. Overall Specifications 3. Warranty 4. Door Overall Dimensions Standard locations 5. Door Construction 6. Total Preassembled Dimensions 7.

More information

COMMERCIAL DOOR HARDWARE PRODUCT CATALOG HOME DEPOT EXCLUSIVE SPECIAL ORDER PROGRAM FOR MORE INFORMATION

COMMERCIAL DOOR HARDWARE PRODUCT CATALOG HOME DEPOT EXCLUSIVE SPECIAL ORDER PROGRAM FOR MORE INFORMATION HOME DEPOT EXCLUSIVE SPECIAL ORDER PROGRAM COMMERCIAL DOOR HARDWARE PRODUCT CATALOG FOR MORE INFORMATION Find Universal Hardware in QuoteCenter Downloadable version of this catalog can be found at UniversalHardware.com

More information

SonoSelect and SonoSafe energy meters

SonoSelect and SonoSafe energy meters energy meters 03/2017 Danfoss VUIGB602 www.heating.danfoss.com 1 Note! To ensure latest version of declaration, please visit danfoss.com. 2 Danfoss Energy Meters 2017.03 VUIGB702 Contents 1. Inside the

More information

Door Closers Contents

Door Closers Contents Door Closers Contents Overhead position door closers Door closer StarTec...10 Door closer GEZE...12 Door closer StarTec...15 -.20 Door closer GEZE...21 -.28 Accessories...29 Overhead door closer...30

More information

Operating Instructions (Translation)

Operating Instructions (Translation) Product Description Definition The ANTARES RCU consists of the ANTARES Head Module and the ANTARES Connection Module. The ANTARES Head Module contains a CPU, communication interface and power pack. In

More information

base+ The intelligent garage door operator Expandable with a wide range of additional equipment

base+ The intelligent garage door operator Expandable with a wide range of additional equipment base+ The intelligent garage door operator Expandable with a wide range of additional equipment ACCESSORIES Track extensions Track extension set Length 1096 mm, incl. ceiling bracket, long isolator chain

More information

Corbin Russwin. Latches, cylinders, interchangeable CORE & spindle. Latches. Lockset Cylinders. Rim Cylinders. Interchangeable Core.

Corbin Russwin. Latches, cylinders, interchangeable CORE & spindle. Latches. Lockset Cylinders. Rim Cylinders. Interchangeable Core. Latches Corbin Russwin Latches, cylinders, interchangeable CORE & spindle Mfg # Series Backset EZ # 486F90 626 4200 2-3/4 035270 Lockset Cylinders Mfg # Series Keyway EZ # 2000 052 59A1 626 4200, 5200

More information

SPARE PARTS AND VARIOUS ACCESSORIES

SPARE PARTS AND VARIOUS ACCESSORIES SPARE PARTS AND VARIOUS ACCESSORIES .066D/S Plate (holes Ø6) + cylinder fastening screw for cylinder locks with Mottura fitting fixing The item is supplied left or right-hand (specify in the order).101n5

More information

For further assistance, call

For further assistance, call DOOR HANDLS - VARIOUS Inside: - Alpha Standard Door Handle - Scrolled Door Handle - Traditional Styled Door Handle - Lock Lock Security Door Handle - Yale Conexis L1 Smart Lock Door Handle - Push Button

More information

Accessories 286 SDC SECURITY DOOR CONTROLS

Accessories 286 SDC SECURITY DOOR CONTROLS 8 Security Door Controls From wireless remote controls to durable door holding & release devices, to REX sensors, timers, ball and magnetic switches, and from concealed contact to universal mounting enclosure

More information

Small Format Interchangeable Core (SFIC) Cylinders

Small Format Interchangeable Core (SFIC) Cylinders Small Format Interchangeable Core (SFIC) Cylinders The L-Series lockset can be ordered to accept small format interchangeable cores (SFIC) compatible with manufacturers such as Falcon, Arrow and Best;

More information

www.hafeleindia.com www.hafeleindia.com FIRE EXIT DOOR HARDWARE Hardware provides the much needed operational functionality to doors. It also enables you to distinguish spaces and helps provide privacy

More information