1 BNA PLENUM FAN with Backward Wheels

2 BNA Series PLENUM FAN with Backward Wheels

3 BNA Series BNA Series Plenum Fans Backward wheels Kruger Plenum Fans are designed for air handling applications where the fan operates unhoused within a pressurized plenum. This results in a saving of space normally occupied by the fan housing, transitions and diffusers. The fan wheel pressurizes the entire surrounding air plenum in which the fan is installed. This allows air ducts from any direction to be directly connected to the air handling unit enclosure. The compact size of the plenum fan makes it an excellent selection for retrofit and replacement application and for variable air volume systems. Type / Operating Limit Each fan type has its maximum operating speed and power due to its mechanical design. The operating limit of BNA series - fan type is design to meet the requirement of class I, II and III limit as defined in AMCA standard The BNA series is available in Direct Driven and Belt Driven, Type D, T or U as small letter Shown: Type D This type is supplied with motor support minimal maintenance with no belts or pulley. It is a compact, space saving design with motor directly connected to wheel. This construction is mainly for cleanroom, with or without VFD, since there is an absence of belt residue which may contaminate the airstreams. Fan Size : 315 to 1400 Volume : 1000 to m 3 /h Total Pressure : up to 4000 Pa Type T Compact design of reduced shaft length with a bearing located in the inlet. It requires separate base for motor mounting. Fan Size : 315 to 1400 Volume : 1000 to m 3 /h Total Pressure : up to 4000 Pa Drawing and dimension of type T available upon request. Type U No bearings in the fan inlet to effect performance, requires separate base for motor mounting. Fan Size : 315 to 1400 Volume : 1000 to m 3 /h Total Pressure : up to 4000 Pa Drawing and dimension of type U available upon request. Wheel TECHNICAL SPECIFICATION The wheel of BNA series has backward curved blades manufactured in cold rolled sheet steel with polyester powder coating finish. Shaft Shafts are manufactured from C45 carbon steel using an automatic process for positioning and cutting of the keyways. All dimensional tolerances of the shaft are fully checked to ensure a precision fit and then coated with an anti-corrosion varnish after assembly. 2

4 BNA Series Bearings Bearings used are either deep groove ball bearing type with an adapter sleeve, or spherical roller bearings type sealed at both sides for different duty application. The bearings are lubricated for life and maintenance-free. If relubrication is necessary, it is recommended to use lithium base grease suitable for all temperatures within the operational limits. Balancing Quality All wheels are statically and dynamically balanced to ISO1940 and AMCA 204 G2.5 standards. All fans after assembly are trim-balanced to ISO1940 and AMCA G2.5 standard. Clean room application fans with balancing grade of G1.0 are available upon request. ACCESSORIES Inlet Guards Inlet guards may be a requirement stated in some industrial safety regulations. These are available on request. Motor Selection The power curve shown on each performance curve represents the absorbed power at the shaft of the fan measured in kw. To determine the power of the motor to be installed, a correction factors should be applied to compensate for transmission losses. For conversion to horsepower (HP), use multiplying factor Correction Factor, % motor power output Pole 4 & 6 Pole Motor power output (kw)

5 BNA Series Performance The performance data shown on each diagram has been tested and measured in accordance to AMCA Standard 210 Fig 12 installation type B (free inlet and ducted outlet condition). The performance is achieved under test conditions of radial discharge, smooth air flows with the aid of proper transitions from plenum outlet to duct, and in a plenum which meets the recommended minimum distance for plenum fans installation. An outlet duct of appropriate size, which gives a reasonable outlet velocity to overcome losses, has also been employed. Rating is referred to the standard air density with the total pressure as a function of the air volume, using logarithmic scales. It is essential that, the same installation type and test standards are used at all times, when comparing fan performances. Noise The noise level shown on each diagram refer to the sound power "Aweighted" and the data on the inlet side has been measured in accordance with AMCA Standard 300. The noise levels of the fans are determined as follows: Sound power level - ("A" scale): Lw (A) as catalogue Octave band spectrum: Lw = Lw(A) + Lw rel. db [refer to Kruger for more details] Sound pressure level: a) free field Lp(A) = Lw(A) - (20log 10 d) -11 b) room conditions Lp(A) = Lw(A) - (20log 10 d) -7 where d = distance of fan (m) SELECTION GUIDELINES To assure optimum performance and be able to use plenum effect pressure loss indicated in the next section, the following guidelines should be adhered to in the plenum fan selection. Minimum Distance Recommended minimum distances for correct plenum fan installation. D = Impeller Diameter

6 BNA Series Plenum Radial Duct Discharge Axial Duct Discharge PLA = K* x Pd Discharge Direction Plenum Effect Loss Fan performance is developed from test conditions of radial discharge. The pressure loss associated with the duct take off, from the plenum, at a different location must be added to the static pressure required of the fan. The correction factor, K*, for pressure loss for axial discharge can be obtained below. Pressure Loss Coefficient, K* Worked Example: Required duty Air volume Q, 8m 3 /s and static pressure P s, 1500Pa with Discharge duct A=1m², For Axial Duct Discharge:- Outlet Velocity, V = Q/A = 8/1 = 8 m/s From chart, at outlet velocity, 8m/s, pressure loss coefficient, K* = 1.4. Pressure loss = K* x Dynamic Pressure, P d = K* x (V/1.3)² = 1.4 x (8/1.3)² = 53 Pa Actual Required static pressure P s = = 1553 Pa Fan Outlet Velocity (m/s) Required Plenum fan selection is to be done with the below duty: Q = 8 m 3 /s and Static Pressure P s = 1553 Pa

7 K R U G E R G R O U P ( V E N T I L A T I O N ) SINGAPORE SINGAPORE KRUGER VENTILATION INDUSTRIES PTE LTD KRUGER ENGINEERING PTE LTD No. 17, Tuas Avenue 10 No. 17, Tuas Avenue 10 Singapore Singapore Tel Fax Tel Fax mktg@krugerasia.com mktg@krugerasia.com MALAYSIA THAILAND KRUVENT INDUSTRIES (M) SDN BHD KRUGER VENTILATION IND. (THAILAND) CO. LTD Lot 8, Jalan Perusahaan 2 Batu Caves 1/19 Moo 2 Rama II Rd, Tasai Industrial Area, Batu Caves Selangor Mueng Samuthsakorn 74000, Thailand Tel Fax Tel / Fax /377 mktg@kruger.com.my mktg@kruger.co.th BEIJING GUANGZHOU BEIJING KRUGER VENTILATION CO. LTD GUANGZHOU KRUGER M&E INDUSTRIES LTD No. 1A South Industry Area No Maogang Road, Huangpu Beijing Economical And Technological Guangzhou, P.R. China Development Area, Beijing China Tel Fax Tel Fax gzkruger@krugerchina.com krugerbj@krugerchina.com HONG KONG SHANGHAI KRUGER VENTILATION (HONG KONG) LIMITED SHANGHAI KRUGER INDUSTRIES CO. LTD Flat C, 9/F, Yeung Yiu Chung (No.8) Industrial Building, No. 500 Yuanguo Road, Anting, Jiading, 20 Wang Hoi Road, Kowloon Bay, Kowloon, Hong Kong Shanghai P.R. China Tel Fax Tel Fax cfyau@kruger.com.hk shkruger@krugerchina.com WUHAN TAIPEI WUHAN KRUGER INDUSTRIES CO. LTD KRUGER VENTILATION (TAIWAN) CO. LTD No. 12 Heping Tieji Industries Parden Hongshan No. 157, Ping-an Rd, Hengfeng Village, Economic Zone, Wuhan P.R.China Dayuan Shiang Taoyuan County 337, Taiwan(ROC) Tel Fax Tel Fax whkruger@krugerchina.com kyyang@krugertwn.com.tw PHILIPPINES AUSTRALIA KRUGER M&E INDUSTRIES CORPORATION KRUGER VENTILATION (AUSTRALIA) PTY LTD FAPI Compound, E. Rodriguez Ave. 4 Blackfriar Place, Wetherill Park Tunasan, Muntinlupa City, Philippines 1773 NSW 2164, Australia Tel Fax Tel Fax mktg@krugerph.com krugerfans@bigpond.com INDONESIA INDIA P.T. KRUGER VENTILATION INDONESIA KRUGER VENTILATION INDUSTRIES (INDIA) PVT LTD JL. Teuku Umar No.20, Kruger Centre, Mumbai-Nashik Highway, Karawaci - Tangerang 15115, Indonesia Atgaon, Shahapur, Thane , India Tel Fax Tel /008/275 - Fax kia@krugerindo.co.id sales@krugerindia.com Chennai: Delhi: Bangalore: Mumbai: Kolkatta: KOREA NEOMATE TECHNOLOGY & CONSULTING CO. LTD , Ace High Tech City B/D, Mullae-dong 3-ga Yeongdeungpo-gu, Seoul, Korea Tel /3 - Fax neomatetnc@chol.com VIETNAM KRUGER VENTILATION INDUSTRIES PTE LTD (Vietnam Representative Office) 4 th floor, HHM Office Building, Xuan Hong St, Tan Binh Dist, Hochiminh City, Vietnam Tel Fax mktg@krugervn.com The company is always improving and developing its products, therefore the company reserves the right to make changes to the illustrated products. Certified dimension will be provided upon request. Edition 1 Printed on June 08

8 Kruger Ventilation Industries Pte Ltd No. 17 Tuas Avenue 10 Singapore Tel Fax CNo. - CAT012.E1 December 2007

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels KAT DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels KAT Series DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels Kruger Ventilation Industries certifies that the KAT series : version S and C - model 9-7

More information

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels KAT DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels KAT Series DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels Kruger Ventilation Industries Asia Co., L td certifies that the KAT series : version S

More information

General Instructions (Plenum & Plug Fan) BNA-ANA- BPA-APA

General Instructions (Plenum & Plug Fan) BNA-ANA- BPA-APA General Instructions (Plenum & Plug Fan) BNA-ANA- BPA-APA IGB030.E0/1203 1 This manual is to guide the users in the proper storage, installation, operation and maintenance procedures to ensure maximum

More information

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels BSB SINGE INET ENTRIUGA AN with Backward heels BSB Series SINGE INET ENTRIUGA AN with Backward heels Kruger Ventilation Industries certifies that the BSB series shown herein is licensed to bear the AMA

More information

VQ N SINGLE INLET INDUSTRIAL FAN. with Backward Wheels

VQ N SINGLE INLET INDUSTRIAL FAN. with Backward Wheels VQ N SINGLE INLET INDUSTRIAL FAN with Backward Wheels VQN Series SINGLE INLET INDUSTRIAL FAN with Backward Wheels Kruger Ventilation Industries Pte Ltd certifies that the VQN Series model 711 to 2001

More information

ADA-BDA-BDB-FDA-KAT ASA-BSB-BSA-FSA

ADA-BDA-BDB-FDA-KAT ASA-BSB-BSA-FSA General Instructions (Centrifugal Fan) ADA-BDA-BDB-FDA-KAT ASA-BSB-BSA-FSA IGB016.E1/0902 This manual is to guide the users in the proper storage, installation, operation and maintenance procedures to

More information

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels KAT DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels KAT Series DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels Kruger Ventilation Industries certifies that the KAT series : version S and - model 9-7 to

More information

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels BSB SINGE INET ENTRIFUGA FAN with Backward heels BSB Series SINGE INET ENTRIFUGA FAN with Backward heels Kruger Ventilation Industries certifies that the BSB series shown herein is licensed to bear the

More information

BDB. DOUBLE INLET CENTRIFUGAL FAN with Backward Wheels

BDB. DOUBLE INLET CENTRIFUGAL FAN with Backward Wheels BDB DOUBE INET ENTRIFUGA FAN with Backward Wheels BDB Series DOUBE INET ENTRIFUGA FAN with Backward Wheels Kruger Ventilation Industries certifies that the BDB series shown herein is licensed to bear

More information

BSB SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

BSB SINGLE INLET CENTRIFUGAL FAN with Backward Wheels BSB SINGE INET ENTRIUGA AN with Backward heels BSB Series SINGE INET ENTRIUGA AN with Backward heels Kruger Ventilation Industries certifies that the BSB series shown herein is licensed to bear the AMA

More information

ASA. SINGLE INLET CENTRIFUGAL FAN with Airfoil Wheels

ASA. SINGLE INLET CENTRIFUGAL FAN with Airfoil Wheels ASA SINGE INET ENTRIUGA AN with Airfoil heels ASA Series SINGE INET ENTRIUGA AN with Airfoil heels Kruger Ventilation Industries certifies that the ASA series shown herein is licensed to bear the AMA Seal.

More information

BDB DIDW CENTRIFUGAL FAN with Backward Wheel TYPE X TYPE T

BDB DIDW CENTRIFUGAL FAN with Backward Wheel TYPE X TYPE T DIDW CENTRIFUGAL FAN with Backward Wheel BDB 0 BDB 0 is DIDW centrifugal fan with high efficiency nonoverloading backward curved impeller. The wheel of BDB 0 is made of cold rolled sheet steel with polyester

More information

AXIAL FANS Catalogue CN0050C01 May 2008

AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 Construction Specifications Impellers: Breezax aerfoil blades are available in four types of material: Glass Reinforced

More information

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS New Energy Saving Wheel Mounted Motors to 125 HP Pre-Engineered Sizes to 60" Capacities to 156,000 CFM CHICAGO BLOWER CORPORATION GLENDALE

More information

POSITIVE PRESSURE DAMPER PRESSURE RELIEF DAMPER KYODO-ALLIED TECHNOLOGY PTE LTD

POSITIVE PRESSURE DAMPER PRESSURE RELIEF DAMPER KYODO-ALLIED TECHNOLOGY PTE LTD POSITIVE PRESSURE DAMPER PRESSURE RELIEF DAMPER KYODO-ALLIED TECHNOLOGY PTE LTD 8 Pandan Crescent #01-06, Singapore 128464 Tel: (65) 6265 111 Fax: (65) 6265 8100 Website: www.kyodo.com.sg MODEL: KBD This

More information

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive Centrifugal Inline s Models SQ-M and BSQ-M Direct and Belt Drive July 2010 Centrifugal Inline Duct s Greenheck's model SQ-M and BSQ-M centrifugal square inline fans feature a unique combination of installation

More information

PEDESTAL PLUG FANS FPP SERIES, HIGH EFFICIENCY CATALOGUE

PEDESTAL PLUG FANS FPP SERIES, HIGH EFFICIENCY CATALOGUE PEDESTAL PLUG FANS FPP SERIES, HIGH EFFICIENCY CATALOGUE FPP SERIES, PEDESTAL PLUG FANS, HIGH EFFICIENCY MOTORS WHEEL DIAMETER: 250mm TO mm MOTORS 0.75kW TO 37kW HOW TO SELECT 3 SPECIFICATIONS 4 INSTALLATION

More information

Bearings for the Cement and Ready-Mix Concrete Industries

Bearings for the Cement and Ready-Mix Concrete Industries Bearings for the Cement and Ready-Mix Concrete Industries Market leading NSK technology that increases bearing life and reduces maintenance costs and downtime. Upgrading to NSK takes your operation to

More information

SUBMERSIBLE 4" PUMPS 4 PUMP - SVM SERIES

SUBMERSIBLE 4 PUMPS 4 PUMP - SVM SERIES SUBMERSIBLE 4" PUMPS 4 PUMP - SVM SERIES 1 TABLE OF CONTENTS 4 PUMP SERIES PAGE SVM30...4 SVM55...6 SVM70...8 SVM100...10 1.32 1.98 2.64 3.30 3.96 4.62 5.28 5.94 6.61 7.27 EN ISO 9906 SUBMERSIBLE PUMPS

More information

MARATHON SLA SERIES CAST ALUMINIUM MULTI-MOUNT THREE PHASE MOTORS SIZES , KW

MARATHON SLA SERIES CAST ALUMINIUM MULTI-MOUNT THREE PHASE MOTORS SIZES , KW MARATHON SLA SERIES CAST ALUMINIUM MULTI-MOUNT THREE PHASE MOTORS SIZES 56-160, 0.09-18.5KW MARATHON SLA SERIES CAST ALUMINIUM MULTI-MOUNT THREE PHASE MOTORS SIZES 56-160, 0.09-18.5KW INTRODUCTION 3 Standards

More information

COMMERCIAL DUTY PLENUM FANS

COMMERCIAL DUTY PLENUM FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN CATALOG 455 JUNE 2014 PLENUM FANS Overview EPLFN I EPLQN Plenum fans are unhoused fans designed

More information

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN CATALOG 455 June 2014 PLENUM FANS Overview EPLFN I EPLQN Plenum fans are unhoused fans designed to operate inside of field-fabricated

More information

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans The Straight Way Rectangular Cabinet Fan Systemair India Pvt. Ltd. certifies that the Rectangular

More information

High Static Fan Coil Units YDFC

High Static Fan Coil Units YDFC Static Fan Coil Units YDFC Contents contents Product information...3 Nomenclature & features...4 Features & benefits...4 Product details...5 Technical specifications...6 Unit dimensions ST type...7 Unit

More information

ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES

ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES COMEFRI USA: Manufacturing and Warehouse facilities in Hopkinsville, KY. Total facility: 125,000 sq.ft. Producing centrifugal fans

More information

NEW. PLASTIC MODULAR CHAIN WT0705-W Plastic Top Chain

NEW. PLASTIC MODULAR CHAIN WT0705-W Plastic Top Chain NEW PLASTIC MODULAR CHAIN WT0705-W Plastic Top Chain A new 7.5 mm-pitch chain has been added to our lineup of plastic modular chains. Features of WT0705-W Plastic Modular Chain Knife-edge conveyor applications

More information

MDM. Magnetic drive pumps Magnetic drive process pump resistant to dry run damage. Magnetic drive pumps. series

MDM. Magnetic drive pumps Magnetic drive process pump resistant to dry run damage. Magnetic drive pumps. series MDM series Magnetic drive pumps Magnetic drive process pump resistant to dry run damage Magnetic drive pumps The MDM Series of Magnetic drive process pumps have wetted parts made of fluororesin. Patent

More information

MARATHON HLA SERIES HLA CAST ALUMINIUM MULTI-MOUNT THREE PHASE MOTORS SIZES , KW

MARATHON HLA SERIES HLA CAST ALUMINIUM MULTI-MOUNT THREE PHASE MOTORS SIZES , KW MARATHON HLA SERIES HLA CAST ALUMINIUM MULTI-MOUNT THREE PHASE MOTORS SIZES 80-160, 0.75-18.5KW MARATHON HLA CAST ALUMINIUM MULTI-MOUNT THREE PHASE MOTORS SIZES 80 TO 160, 0.75 TO 18.5KW INTRODUCTION 3

More information

Max. flow capacity of 5,000 L/min and max. discharge head of 98m. The world s largest class fluoroplastic magnetic drive pump.

Max. flow capacity of 5,000 L/min and max. discharge head of 98m. The world s largest class fluoroplastic magnetic drive pump. MDW series Magnetic drive pumps Max. flow capacity of 5,000 L/min and max. discharge head of 98m. The world s largest class fluoroplastic magnetic drive pump. The MDW series are the largest class fluoroplastic

More information

air handling units YAH

air handling units YAH air handling units YAH Air Handing Units YAH Series YORK YAH series ceiling-mounted air handling units are terminal points of central air-conditioning systems. They are designed for fresh air units or

More information

SARAVEL CENTRIFUGAL FANS For Airconditioning & Industrial Application

SARAVEL CENTRIFUGAL FANS For Airconditioning & Industrial Application CAT.NO. 120-97 SARAVEL CENTRIFUGAL FANS For Airconditioning & Industrial Application TABLE OF CONTENTS Introduction......3 Selection Examples......4-5 Correction Factors......6 Rating Tables.........7-17

More information

YASKAWA AC DRIVES. Application Solution. Extruder. YASKAWA AC Drive GA700. YASKAWA Matrix Converter U1000

YASKAWA AC DRIVES. Application Solution. Extruder. YASKAWA AC Drive GA700. YASKAWA Matrix Converter U1000 YASKAWA AC DRIVES Application Solution Extruder YASKAWA AC Drive YASKAWA Matrix Converter For Extruder YASKAWA provides the answers to your extruder needs. YASKAWA ELECTRIC always stands in the shoes of

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalogue air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalogue Contents GENERAL Description and survey chart Application... 3 General Survey

More information

VCPA Plastic Centrifugal Fan Air Flows up to 6,000 CFM and static pressures to 10 inches w.c.

VCPA Plastic Centrifugal Fan Air Flows up to 6,000 CFM and static pressures to 10 inches w.c. VCPA Plastic Centrifugal Fan Air Flows up to 6,000 CFM and static pressures to 10 inches w.c. www.amcec.com sales@amcec.com VCPA Plastic Centrifugal Fan VCPA Plastic Centrifugal Fan Housing: Standard PPH

More information

BPF. Centrifugal Plug Fans

BPF. Centrifugal Plug Fans BPF Centrifugal Plug Fans Introduction INTRODUCTION Plug Fans S&P - THE COMPANY Soler & Palau was founded in 1951 in Ripoll (Spain) and since this date has become one of the world s leading companies engaged

More information

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series 0 017982 603075 A P P L I C A T I O N S Range of plate mounted axial fans manufactured from high grade galvanised steel

More information

Spherical Roller Bearings

Spherical Roller Bearings Spherical Roller Bearings Introducing the newest series of advanced, high performing spherical roller bearings offering higher speed and load capacities suitable for a wide variety of industrial applications.

More information

Tubular Centrifugal Fans

Tubular Centrifugal Fans Tubular Centrifugal Fans Model TCB Inline - Horizontal or Vertical Roof Upblast and Roof Supply March 2007 Tubular Centrifugal Fans The TCB series of inline centrifugal fans is designed for ducted inline,

More information

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA IWAKI MAGNETIC DRIVE PUMPS Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA Magnetic drive process pump resistant to dry run damage The Series of Magnetic drive process pumps have wetted parts made of fluororesin.

More information

AC Commercial Fans Edition. ErP ready

AC Commercial Fans Edition. ErP ready AC Commercial Fans 213 Edition ErP ready AC Commercial Fans Axair Fans UK Ltd / 1782 34943 About Axair Fans UK Axair is an independent industrial fan manufacturer and distributor. What we offer : Application

More information

36 / 72.5kV Dry Air Insulated Dead Tank Vacuum Circuit Breaker

36 / 72.5kV Dry Air Insulated Dead Tank Vacuum Circuit Breaker 36 / 72.5kV Dry Air Insulated Dead Tank Vacuum Circuit Breaker 1 Features The Dry Air Insulated Dead Tank VCB was born of superb technology and abundant production experience of Meidensha Corporation.

More information

D6..M.. Butterfly Valves

D6..M.. Butterfly Valves D6..M.. Butterfly Valves Technical Databook Ver. Version 2 2.0 Belimo Asia Pacific D6..MH/MW Series Butterfly Valves Trade Selection by Belimo 2-way Butterfly Valves flanged DN50...500 For Open/Close or

More information

Copeland Scroll TM IZSI condensing unit for refrigeration applications

Copeland Scroll TM IZSI condensing unit for refrigeration applications Copeland Scroll TM IZSI condensing unit for refrigeration applications Product Catalogue Pioneering Technologies For Best-In-Class Products merson Climate Technologies is the world s leading provider of

More information

Introducción Introduction

Introducción Introduction Introducción Introduction S&P - LA EMPRESA Desde su fundación en el año 1951, en la localidad de Ripoll (España), Soler & Palau, S.A. se ha convertido, desde hace ya bastantes años, en uno de los líderes

More information

Inline Fans [ 14 ] * UL is optional and must be specified.

Inline Fans [ 14 ] * UL is optional and must be specified. XTIF, XIB and XID models are listed for electrical (UL/C-UL US 705) File no. E40001. Model XTIF is available with the UL 762 Listing (Power Ventilators for Restaurant Exhaust Appliances). Accurex, LLC

More information

Tsubaki Power and Performance. For the Medical Equipment Industry

Tsubaki Power and Performance. For the Medical Equipment Industry Tsubaki Power and Performance For the Medical Equipment Industry A wide range of Tsubaki products support the needs of the medical industry. Meeting customers' needs for quality and functionality and contributing

More information

You ll find many Tsubaki products being

You ll find many Tsubaki products being You ll find many Tsubaki products being There are many processes involved in making a motor vehicle. You ll find Tsubaki products in all of these processes, from conveying vehicle bodies from the stockyard,

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalouge air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalouge Contents GENERAL Description and survey chart Application... 3 General Survey

More information

Centrifugal Upblast Power Roof Ventilators

Centrifugal Upblast Power Roof Ventilators INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Upblast Power Roof Ventilators TYPE UBCA - BELT DRIVE TYPE UDCA - DIRECT DRIVE TABLE OF CONTENTS UBCA Sizes 06 to 44 Flow rates from 229 to 29,002 CFM

More information

Steam Valves with Rotary Actuators

Steam Valves with Rotary Actuators Steam Valves with Rotary Actuators Technical Databook Version 3.1 Belimo Asia Pacific Steam Valve Product overview 2-way Steam Valves DN15...80 Equal-percentage characteristics for modulating control of

More information

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance GENERAL VENTILATOR A quality product suitable for general residential application. proprietary made and compact design fan is designed

More information

SMX-F. Self-priming magnetic drive pumps. Chemically resistant self-priming magnetic drive pumps which can tolerate abnormal operation CFRETFE

SMX-F. Self-priming magnetic drive pumps. Chemically resistant self-priming magnetic drive pumps which can tolerate abnormal operation CFRETFE SMX-F series Self-priming magnetic drive pumps Chemically resistant self-priming magnetic drive pumps which can tolerate abnormal operation Self-priming magnetic drive pumps Main material CFRETFE The SMX-F

More information

Class I Microbiological Safety Cabinets The Leading Energy Efficient, Quiet, and Ergonomic Biosafety Cabinet

Class I Microbiological Safety Cabinets The Leading Energy Efficient, Quiet, and Ergonomic Biosafety Cabinet Class I Microbiological Safety Cabinets The Leading Energy Efficient, Quiet, and Ergonomic Biosafety Cabinet Airstream Class I Biosafety Cabinet, Model AC1-4E8 RS 232 Port and Zero Volt Relay Contact RS

More information

DESIGN GUIDELINES FANS PAGE 1 of 7

DESIGN GUIDELINES FANS PAGE 1 of 7 DESIGN GUIDELINES FANS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification to the

More information

Magnetic drive pumps A worldwide best-seller, our high-quality compact magnetic drive pumps

Magnetic drive pumps A worldwide best-seller, our high-quality compact magnetic drive pumps MD series Magnetic drive pumps A worldwide best-seller, our high-quality compact magnetic drive pumps Main material Magnetic drive seal-less pumps are free from leakage problems and the need for seal replacement.

More information

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ Duct mounted fans axial flow Pacific HVAC Engineering 215 www.pacifichvac.com Tel. Australia 13 733 833 NZ 8 1 326 6 5 4 3 2 1 5 1 15 2 7 6 5 4 3 2 1 3 2.5 2 1.5 1.5 1 15.5 1 1.5 2 2.5 3 3.5 Volume m 3

More information

Centrifugal Fans belt driven. TD_CFB-RDY_EN Issue 1.1 EN July 2013

Centrifugal Fans belt driven. TD_CFB-RDY_EN Issue 1.1 EN July 2013 Centrifugal Fans belt driven TD_CFB-RDY_EN Issue 1.1 EN July 2013 Y D R 1 AMCA Nicotra Gebhardt S.p.A. certifi es that the fan shon herein is licensed to bear the AMCA Seal. The ratings shon are based

More information

TDF Double Inlet Backward Curve Centrifugal Fans

TDF Double Inlet Backward Curve Centrifugal Fans TDF Double Inlet Backward Curve Centrifugal Fans Product overview TDF series of backward curved centrifugal fans are used in a wide variety of applications designed for high efficiency and low noise.

More information

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404) 500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT Table of Contents General Information...3 500-YCI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor

More information

forward curved inline duct blowers

forward curved inline duct blowers Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)

More information

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA IWAKI MAGNETIC DRIVE PUMPS Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA Magnetic drive process pump resistant to dry run damage The Series of Magnetic drive process pumps have wetted parts made of fluororesin.

More information

Mixed Flow Inline Fan, Model MFSI

Mixed Flow Inline Fan, Model MFSI Mixed Flow Inline Fan, Model MFSI TABLE OF CONTENTS 3 Introduction, Certifications & Listings 4 Features & Benefits 5 Options & Accessories 6 Dimensional Data 10 Performance Data 27 Sound Data 44 Engineering

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Why Use a Tolerance Ring?

Why Use a Tolerance Ring? Why Use a? BENEFITS OF TOLERANCE RINGS Reduced cost Improved vibration characteristics Secure mounting across a large operating temperature range Elimination of complex machining operations Relaxed tolerances

More information

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent & Pat.Pend. JAPAN / U.S.A. / EU / CHINA / TAIWAN

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent & Pat.Pend. JAPAN / U.S.A. / EU / CHINA / TAIWAN IWAKI MAGNETIC DRIVE PUMPS Patent & Pat.Pend. JAPAN / U.S.A. / EU / CHINA / TAIWAN Magnetic drive process pump resistant to dry run damage The Series of Magnetic drive process pumps have wetted parts made

More information

YASKAWA AC DRIVES. Application Solution. Injection Molding Machine. YASKAWA AC Drive GA700. YASKAWA Matrix Converter U1000

YASKAWA AC DRIVES. Application Solution. Injection Molding Machine. YASKAWA AC Drive GA700. YASKAWA Matrix Converter U1000 YASKAWA AC DRIVES Application Solution Injection Molding Machine YASKAWA AC Drive YASKAWA Matrix Converter For Injection Molding Machine YASKAWA provides the answers to your injection molding machine needs.

More information

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS S ACON EQ NTS ACON E NTS A S EQ A TS TS TS TS TS E AC AC AC AC AC AC S S UIP IPME IPME QU P QUI QUI EQ EQUI Q EQ EQ EQ EQ EN EN SE SE SEAC AC AC AC AC AC AC ACO EQUIP E MEN SEACO EQUIPMEN A EQU EQU AC

More information

TMC Semi-trailer Landing Gear Service Manual

TMC Semi-trailer Landing Gear Service Manual TMC Semi-trailer Landing Gear Service Manual The Group Disclaimer Versioning The author and publisher have made their best efforts to prepare this manual, and the information contained in this manual is

More information

Magnetic drive pumps. A worldwide best-seller, our high-quality compact magnetic drive pumps GFRPP. Magnetic drive pumps. series.

Magnetic drive pumps. A worldwide best-seller, our high-quality compact magnetic drive pumps GFRPP. Magnetic drive pumps. series. MD series Magnetic drive pumps A worldwide best-seller, our high-quality compact magnetic drive pumps Magnetic drive pumps Main material Magnetic drive seal-less pumps are free from leakage problems and

More information

MOTORS MT SERIES CAST ALUMINIUM SINGLE & THREE PHASE EXTENDED RANGE NOW INCLUDES MTTB BRAKE MOTOR. Freephone Fax

MOTORS MT SERIES CAST ALUMINIUM SINGLE & THREE PHASE EXTENDED RANGE NOW INCLUDES MTTB BRAKE MOTOR. Freephone Fax Freephone 0508 634 341 Fax 09 634 7417 7 Monier Pl, Mt Wellington, Auckland 1060, New Zealand MT SERIES CAST ALUMINIUM SINGLE & THREE PHASE EXTENDED RANGE NOW INCLUDES MTTB BRAKE MOTOR MOTORS www.regalaustralia.com.au

More information

Air Moving Solutions. MODULAR plenum fans

Air Moving Solutions. MODULAR plenum fans Air Moving Solutions. MODULAR plenum fans MPQN MPQS CATALOG 490 March 2012 PlenumFans Models MPQN MPQS The MPQN and MPQS offer many of the same advantages of the venerable EPQN plenum fan. The MPQN and

More information

Good Enough Never Is. Plug Fan SERIES 12

Good Enough Never Is. Plug Fan SERIES 12 Plug Fan SERIES 12 Good Enough Never Is The Hartzell Difference Combine Hartzell QUALITY with your PRODUCT for a BETTER CHOICE for your customers! GOOD ENOUGH NEVER IS. Hartzell Air Movement is the industrial

More information

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Specifications Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Housings: PP* Single block strong high density UV treated and

More information

4 3 FSPA. End Suction Pumps *) Horizontal Split Case Pumps **) FEATURES

4 3 FSPA. End Suction Pumps *) Horizontal Split Case Pumps **) FEATURES FEATURES. Non Overload design to ensure stable performance for all applications 2. Corrosion resistant materials used on the rotating parts 3. Hydraulically balanced impeller extends bearing life and assures

More information

Series TDA DIRECT DRIVEN MODEL: TDA- 450/9AA/8-8/ / Construction. Airflow Direction

Series TDA DIRECT DRIVEN MODEL: TDA- 450/9AA/8-8/ / Construction. Airflow Direction DIRECT DRIVEN Series TDA Construction Double flanged casing is produced in mild steel or galvanised steel, available in short and long cased. The impeller having manually adjustable pitch blades is made

More information

Fiberglass Axial Flow Fans. Series 28 Series 28B. Series 34 Series 35 Series 35V. Series 29 Series 29B HARTZELL

Fiberglass Axial Flow Fans. Series 28 Series 28B. Series 34 Series 35 Series 35V. Series 29 Series 29B HARTZELL Fiberglass Axial Flow Fans Series 28 Series 28B Series 29 Series 29B Series 34 Series Series V BUILT WITH HONOR HARTZELL FAN, INC PIQUA, OHIO USA HARTZELL Hartzell Fan, Inc., Piqua, Ohio 46 Bulletin A-39-N

More information

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

Explanation of AR Series Ventilator Products. Fan type code D S AR AE Series Axial Fan Explanation of Series Ventilator Products Fan type code 450-7 /26 D -2 F400 Smoke Extract Fan 400 C, 300 C Number of Poles D S Three Phase Single Phase AE AE Features and construction

More information

MARATHON MT SERIES CAST ALUMINIUM SINGLE & THREE PHASE GENERAL PURPOSE MOTORS SIZES , KW

MARATHON MT SERIES CAST ALUMINIUM SINGLE & THREE PHASE GENERAL PURPOSE MOTORS SIZES , KW MARATHON MT SERIES CAST ALUMINIUM SINGLE & THREE PHASE GENERAL PURPOSE MOTORS SIZES 56-112, 0.06-3.7KW MT CAST ALUMINIUM GENERAL PURPOSE MOTORS SIZES 56 TO 112, 0.06 TO 3.7 KW, SINGLE & THREE PHASE INTRODUCTION

More information

Unobox units with backward curved centrifugal impellers

Unobox units with backward curved centrifugal impellers Unobox Fans Unobox units with backward curved centrifugal impellers Type Code UNO 67-450 -4 E W Unobox Box size 50=500mm ; 67=670mm 80=800mm ; 102=1020mm Impeller diameter Number of poles D - Three Phase

More information

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven BULLETIN 456 July 1997 VANEAXIAL FANS Type W Direct Drive/Belt Driven Model VW Direct Drive Model VWBD Belt Driven Aerovent certifies that the Type W Vaneaxial Fans shown herein are licensed to bear the

More information

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume PennBarry Fan Guide Specification Laboratory Exhaust System: Model vplume This document 2018 PennBarry vplume is a commercial lab exhaust fan that ensures a greater margin of safety by effectively dispersing

More information

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD The Industrial Choice. Model SCDD Direct Drive Model SCBD Belt Driven SQUARE INLINE FANS Direct Drive & Belt Driven Model SCDD / SCBD BULLETIN 40 January 007 Square Inline Centrifugal Fans General Information

More information

BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS

BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS BSB 03.06-01 BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS Description Construction Fans are not

More information

Soler & Palau. Research Design and High Technology

Soler & Palau. Research Design and High Technology Research Design and High Technology Soler & Palau Sales Department C/ Llevant, 4 Polígono Industrial Llevant 08150 Parets del Vallès (Barcelona) - SPAIN Tel. +34935719420 ax +34935719421 e-mail: oem.info@solerpalau.com

More information

Vibration Isolators (6) Galvanized Wheel. Sealed Ball Bearing. Standard Duct Size Inlet Ring

Vibration Isolators (6) Galvanized Wheel. Sealed Ball Bearing. Standard Duct Size Inlet Ring The Lau FGP Series Blower is perfect for use in ventilating, exhausting, air conditioning, processing and general industrial applications. Cold Rolled Steel: all welded construction with painted enamel

More information

BAC, BAF, BAH Central Station Air Handlers

BAC, BAF, BAH Central Station Air Handlers PRODUCT DATA & INSTALLATION Bulletin B80-BA-PDI-5 Part # 1097717 PRODUCT SUPPORT web: b-rp.ca/bah email: ahu@b-rp.ca call: 1-844-893-3222 x527 scan: BAC, BAF, BAH Central Station Air Handlers Indoor and

More information

CNA-CNB CNA-CNB CENTRIFUGAL FANS STANDARD TEMPERATURES AND EX

CNA-CNB CNA-CNB CENTRIFUGAL FANS STANDARD TEMPERATURES AND EX NA-NB NA-NB ENTRIFUGAL FANS STANDARD TEMPERATURES AND EX PRODUT FATS PRODUT The centrifugal fans type NA and NB are robust and versatile fans of the single-inlet type with backward-curved blades. APPLIATION

More information

Turbo Pressure Blowers

Turbo Pressure Blowers www.americanfan.com Bulletin VP4 Turbo Pressure Blowers Howden Industrial Fan Group American Fan / Joy Fan / Garden City Fan Features Heavy gauge continuously welded housings, reversible and rotatable

More information

RAUFUSION PP-R PLUMBING SYSTEM. Safer. Smarter. More Convenient

RAUFUSION PP-R PLUMBING SYSTEM. Safer. Smarter. More Convenient RAUFUSION PP-R PLUMBING SYSTEM Safer. Smarter. More Convenient SAFER Engineered for your safety and well being Safety is critical when choosing a suitable plumbing system. REHAU RAUFUSION consists of a

More information

NEW Acoustic In-Line Fans (ACQ)

NEW Acoustic In-Line Fans (ACQ) NEW Acoustic In-Line Fans (ACQ) Acoustically treated housing, Class O rated, sandwich construction selected for maximum noise absorption Motors protected to IP44 Motor insulation Class B Maximum operating

More information

Turning Air Into Solutions. PLUG FANS TYPE BCPL

Turning Air Into Solutions. PLUG FANS TYPE BCPL Turning Air Into Solutions. PLUG FANS TYPE BCPL CATALOG 350 December 2009 BCPL Plug Fans BCPL plug fans from Twin City Fan & Blower are compact and versatile. Their versatility allows them to be used for

More information

ISO Interface. Large capacity. Light weight. Accommodates enclosure IP65. Solenoid Valve (with M Connector) Conforming to ISO

ISO Interface. Large capacity. Light weight. Accommodates enclosure IP65. Solenoid Valve (with M Connector) Conforming to ISO P-EX01-A Solenoid Valve (with M Connector) Conforming to ISO 1507-1, Large capacity EVS1-01 (Size: 01) EVS1-0 (Size: 0) Light weight Size 01 (-position): 0.6kg Size 0 (-position): 0.18kg Flow rate 1000L/min

More information

Delta Planetary Gearbox PA Precision Series

Delta Planetary Gearbox PA Precision Series Automation for a Changing World Delta Planetary Gearbox PA Precision Series www.deltronics.ru PA Precision Series Features High Rigidity, High Torque Employs uncaged needle roller bearings with a set design

More information

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

Sidewall Propeller Fans Direct Drive. Exhaust / Supply Sidewall Propeller Fans Direct Drive / February 2009 Sidewall Propeller Fans Greenheck s sidewall propeller fan line is the ideal choice for factory and warehouse applications where high volumes of air

More information

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance A P P L I C A T I O N S PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series Range of plate mounted axial fans manufactured from high grade galvanised steel and provided with

More information

DEN RANGE Compact Ecology Unit for Commercial Kitchen Ventilation. Technical introduction

DEN RANGE Compact Ecology Unit for Commercial Kitchen Ventilation. Technical introduction DEN RANGE Compact Ecology Unit for Commercial Kitchen Ventilation Technical introduction Introduction to DEN range of Compact Ecology Unit DYNAIR is the industrial division of Maico Italia S.p.A. and

More information

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA IWAKI MAGNETIC DRIVE PUMPS Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA Magnetic drive process pump resistant to dry run damage The Series of Magnetic drive process pumps have wetted parts made of fluororesin.

More information

RAS-J air & RGS-J GAS

RAS-J air & RGS-J GAS RAS-J air & RGS-J GAS whispair blowers The original ROOTS blower still leads the way B-5219 rev. 0410 Exclusive WHISPAIR Design Reduces Stress, Vibration and Noise Conventional blowers are buffeted up

More information

Centrimaster GX. Catalogue GX Rev.03 October 2012

Centrimaster GX. Catalogue GX Rev.03 October 2012 Centrimaster GX Catalogue GX Rev.03 October 2012 Versions CENTRIMASTER GX is a new generation centrifugal fan for air handling units. It is available for air flow up to 35 m3/s and for pressure rise up

More information