CUP ACCESSORIES SECTION 4 FLOW VALVES, CHECK VALVES, MECHANICAL VALVES, SWIVEL JOINTS, & TEE ADAPTORS EDCO USA.

Size: px
Start display at page:

Download "CUP ACCESSORIES SECTION 4 FLOW VALVES, CHECK VALVES, MECHANICAL VALVES, SWIVEL JOINTS, & TEE ADAPTORS EDCO USA."

Transcription

1 CUP ACCESSORIES SECTION FLOW ALES, CHECK ALES, MECHANICAL ALES, SWIEL JOINTS, & TEE ADAPTORS 0 EDCO USA. :

2 CUP ACCESSORIES CONTENTS DUAL FLOW ALE TRI-FLOW ALE FLOW SENSOR ALE RELEASE CHECK ALE ACUUM CHECK ALE ACUUM CHECK WITH RELEASE CHECK ALE CONE ALE SWIEL JOINT TEE ADAPTOR ALES, JOINTS, & ADAPTORS Dual Flow alves :3 Tri-Flow alves : Flow Sensor alves :5 - :6 Release Check alves :7 acuum Check alves :8 acuum Check with Release Check alves :9 - :0 Cones alves :0 Mechanical alves : Swivel Joints : Tee Adaptors : MECHANICAL ALE : 0 EDCO USA.

3 DUAL FLOW ALES Dual-Flow alves limit vacuum leakage in a system where some of the suction cups may not be in sealing contact with the work piece. Since vacuum flow is limited by a small orifice, DF valves are only recommended for non-porous parts or for slightly porous light weight parts. There are two main ways to apply DF valves: The first is to bring DF equipped suction cups into contact with the work and then turn on the vacuum source. Non-sealing cups will leak and cause the associated Dual-Flow valves to close to orifice flow only. 0, 5, 30mm Cups SIZING A ACUUM PUMP: From the table below, determine the orifice flow at your system s maximum vacuum operating level. Multiply this by the maximum number of non-sealing cups in the system. Select a pump that will give this total flow rate at the system vacuum level plus a factor of safety. The second way is to turn on the vacuum source to close all DF valves before the suction cups contact the work and then allow the DF orifice flow to establish vacuum within the cups once contact is made. In either case, part release is accomplished by removing the vacuum source and admitting atmospheric air to reopen the Dual-Flow valves. For a faster cycle time, use a blow-off pulse of compressed air to break the vacuum and release the part more quickly. FEMALE DUAL-FLOW ASSEMBLY WEIGHT 8 inhg (6 kpa) CONNECTION FITTING SUFFIX oz. (g) SCFM (Nl/m) THREADS 3-GFDF -GFDF 0.7 (7.7) 0. (5.7) G/ BSPP 3-8FDF -8FDF 0.3 (3.7) 0. (5.7) G/8 NPS 3-5X8FDF -5X8FDF.0 (8.6) 0. (5.7) G/8 NPS 3-5X5FDF -5X5FDF 0.9 (5.) 0. (5.7) M5 x 0.8 (0-3 UNF) MALE DUAL-FLOW ASSEMBLY WEIGHT 8 inhg (6 kpa) CONNECTION FITTING SUFFIX oz. (g) SCFM (Nl/m) THREADS 3-MDF -MDF 0.9 (5.) 0. (5.7) / NPT 3-GMDF -GMDF 0.7 (.8) 0. (5.7) G / BSPP 3-8MDF -8MDF 0.3 (3.7) 0. (5.7) G /8 NPS CAUTION: If DF valves are used with a heavy porous part, the part may be dropped suddenly due to porosity flow through the part being greater than the available orifice flow. This can occour even if there is excess vacuum pump capacity. For this type of system, use Flow Sensor alves. ACUUM 0mm Cups FEMALE DUAL-FLOW ASSEMBLY WEIGHT 8 inhg (6 kpa) CONNECTION FITTING SUFFIX oz. (g) SCFM (Nl/m) THREADS 0-38FDF -38FDF 0.7 (3.3) 0.5 (.) 3/8 NPSF 0-GFDF -GFDF 0.7 (7.7) 0.5 (.) G/ BSPP 0-8FDF -8FDF 0. (6.) 0.5 (.) G/8 NPS 0-5X8FDF -5X8FDF.0 (8.6) 0.5 (.) G/8 NPS 0-5X5FDF -5X5FDF 0.33 (9.) 0.5 (.) M5 x 0.8 (0-3 UNF) MALE DUAL-FLOW ASSEMBLY WEIGHT 8 inhg (6 kpa) CONNECTION FITTING SUFFIX oz. (g) SCFM (Nl/m) THREADS 0-38MDF -38MDF 0.9 (8.) 0.5 (.) 3/8 NPT 0-G38MDF -G38MDF 0.9 (8.) 0.5 (.) G 3/8 BSPP 0-MDF -MDF 0.3 (6.5) 0.5 (.) / NPT 0-GMDF -GMDF 0.3 (6.5) 0.5 (.) G / BSPP 0-8MDF -8MDF 0. (6.) 0.5 (.) G /8 NPS ORIFICE FLOW PRESSURE OR ATMOSPHERE P REERSE FLOW 50mm Cups FEMALE DUAL-FLOW ASSEMBLY WEIGHT 8 inhg (6 kpa) CONNECTION FITTING SUFFIX oz. (g) SCFM (Nl/m) THREADS 50-38FDF -38FDF 0.5 (.5) 0.6 (7) 3/8 NPSF 50-GFDF -GFDF 0.39 (.) 0.6 (7) G/ BSPP 50-8FDF -8FDF 0.5 (7.) 0.6 (7) G/8 NPS 50-5X8FDF -5X8FDF.0 (8.6) 0.6 (7) G/8 NPS 50-5X5FDF -5X5FDF 0.36 (0.) 0.6 (7) M5 x 0.8 (0-3 UNF) MALE DUAL-FLOW ASSEMBLY WEIGHT 8 inhg (6 kpa) CONNECTION FITTING SUFFIX oz. (g) SCFM (Nl/m) THREADS 50-38MDF -38MDF 0.3 (9.6) 0.6 (7) 3/8 NPT 50-G38MDF -G38MDF 0.3 (9.6) 0.6 (7) G3/8 BSPP 50-MDF -MDF 0.5 (7.) 0.6 (7) / NPT 50-GMDF -GMDF 0.8 (7.9) 0.6 (7) G/ BSPP 50-8MDF -8MDF 0. (5.7) 0.6 (7) G/8 NPS 0 EDCO USA. :3

4 TRI-FLOW ALES ACUUM ACUUM PRESSURE OR ATMOSPHERE 0.6 [5.7] P ORIFICE. [9] FILTER FULLY OPEN TO ORIFICE FLOW 0.5 SCFM FLOWRATE CHECK ALE WILL REOPEN IF POROSITY FLOW IS BELOW ABOUT HALF OF CLOSING SETPOINT. TRI-FLOW ALES Tri-Flow alves limit vacuum leakage in a system where some of the suction cups may not be in sealing contact with the work piece. Tri-Flow alves are a cross between Flow Sensor alves and Dual-Flow alves because they are fully open until the Flow Sensor section closes at the factory preset vacuum flow rate, then a bypass orifice meters vacuum flow to limit leakage to a manageable rate. Part release is accomplished by removing the vacuum source and admitting atmospheric air which will also reset any closed Tri-Flow alves to open position. For a faster cycle time, use a blow-off pulse of compressed air to break the vacuum and release the part more quickly. Tri-Flow alves can handle greater porosity flow than Dual-Flow alves due to the fact that they re initially held open. Another advantage is the Tri-Flow metering orifice is protected by an integral filter for greater tolerance of contamination. HOW TO ORDER: To order a cup assembled with a Tri-Flow alve, add suffix -8FTF to the cup part number. Cup fittings must have G /8 NPSF femal thread. Example: XP-B50N-8FTF The normal way to set up a vacuum system using Tri- Flow equipped suction cups is to bring them into contact with the work and then turn on the vacuum source. Nonsealing cups will leak and cause the associated Tri-Flow alve to close to orifice flow only. Tri-Flow alves on cups in sealing contact with the work will remain fully open to handle higher porosity flow rates (normal leakage through the part) than Dual-Flow alves can. For a system handling non-porous parts, operation can be as described above or the vacuum source may be turned on before the suction cups are in sealing contact with the work. Tri-Flow alves can pass vacuum flow through the metering orifice to establish vacuum within the suction cups after they are placed in sealing contact with the work and the Tri-Flow alves will reset to fully open. This feature is also convenient for use in vacuum holding fixtures. This capability is the only advantage that Tri-Flow alves have over Flow Sensor alves. For mid-to-high porosity parts, we recommend using Flow Sensor alves where the closing set point can be adjusted to suit the application. To order for use inline: TF8F-XX with G/8 NPS Female. XX= Specify 0., 0.5 or 0.6 SCFM. Pay attention to cup size when ordering. CUP SIZE TRI-FLOW FITTING CLOSING FLOW RATE 8inHG. 0, 5, FTF 0. scfm 0. scfm REERSE FLOW 0 0-8FTF 0.5 scfm 0. scfm FTF 0.6 scfm 0.5 scfm : 0 EDCO USA.

5 FLOW SENSOR ALES: PATENTED Flow Sensor alves (FS) are normally-open valves that snap closed when the factory preset flow rate is exceeded. Our FS is insensitive to acceleration forces and may be used in any physical orientation. System vacuum level has no effect on the FS set point, however, higher system vacuum levels will cause greater flow rates through a porous work place. Flow Sensor alves eliminate the problem of vacuum loss through non-working standard cups or through valved cups overhanging the work piece edge. These are especially useful where work piece size and orientation will vary. For maximum effective-ness, each suction cup in the system should be equipped with a Flow Sensor alve. When used with large bellows-style suction cups, the cup should be pressed against the work piece to collapse the bellows before turning on the vacuum. This prevents accidentally activating the FS by the high instantaneous flow rate caused by the bellows collapsing under vacuum. The FS will automatically reset when the vacuum is turned off for a short period of time. If desired, a pressure pulse can be used to back flow the FS and clean off the inlet filter. This blow-off pulse will reset the FS and will quickly release the work piece. The FSM version includes a monitor port where a vacuum sensor can be used to monitor whether the FS is open or closed. Flow Sensor alves may be manifold or located in-line rather than at the suction cup. Piping integrity is important since the FS will sense a fitting leak as easily as leakage at a suction cup. Wherever installed, a suitable filter must be used upstream of the FS. When used with EDCO fittings, a filter screen nests inside the fitting bore. The optimum flow rate set point is best determined by testing the porosity of sample work pieces with a flow meter using the same suction cup size and style as will be used in the actual system. Porosity of items such as corrugated board can vary greatly from lot to lot so it is important to find the most porous part to be handled by the system. A factor of safety must be added to the highest porosity test value to allow for variations in work piece porosity, system vacuum level, increased leakage due to wear and other factors. For porous work pieces such as paper and corrugated cases, the factor of safety probably should be in the 50% range. For non-porous work pieces such as plastic or metal, the factor of safety may be reduced. It is necessary to size the vacuum pump to have enough capacity to close all Flow Sensor alves where cups are not sealed against a work piece plus the total porosity flow through the sealed cups. EDCO air powered multi-stage vacuum pumps are ideally suited since they produce large vacuum flow rates at low vacuum levels (0-0 in-hg) and can provide the flow necessary to close a large number of Flow Sensor alves. The FS is a larger / NPT version that is for use with larger suction cups but is functionally the same as FS 8. The FS 0 is for use with 5mm and smaller suction cups but is functionally the same as an FS 8. HOW TO ORDER: FS8 + FLOWRATE (SCFM x 0) + FITTING SIZE. EXAMPLES: FS is a standard FS that is set to close when a flow rate exceeds 0.9 SCFM and includes a size 50 cup fitting and filter screen. FS8-6-8M is an FS set to close when flow rate exceeds 0.6 SCFM and includes a /8 NPT male fitting and filter screen for inline mounting. AAILABLE FLOWRATE SETPOINTS: FS 0 = 0. to 0.6 SCFM in 0. increments FS 8 = 0.3 to.3 SCFM in 0. increments FS = 0.5 to 6.0 SCFM in 0. increments Conversion: SCFM = 8.3 NI /m 0 EDCO USA. :5

6 FLOW SENSOR ALES: PATENTED FS-0-XX BASIC FLOW SENSOR ALE 0.7 [8] M5 X 0.8 (0-3 UNF) HEX [9.5] FLOW DIRECTION ACUUM PUMP SUCTION CUP G/8 NPT FLOW FS-8-XX BASIC FLOW SENSOR ALE 0.35 [8.9] 0.7 [8.8].60 [0.6] -50 SIZE 50 FITTING FLOW FS350 FILTER SCREEN, TYPICAL 0. [.] -8M /8 NPTF FSM-8-XX BASIC FLOW SENSOR ALE WITH MONITOR PORT Monitor Port 0.7 [8.8].60 [0.6] 0.35 [8.9] -0 SIZE 0 FITTING NOTE: Flow Sensors are calibrated using a flow meter. Field adjustment is not practical. 5 mm HEX FLOW G/8 NPS M5 X 0.8 (0-3 UNF) MONITOR PORT OPTIONAL CLOSE NIPPLE N-G8MX6 5 [.3] 0.50 [.7] -M5 M5 X 0.8 (0-3 UNF) FOR SIZE 0 & 5 FITTINGS 0.39 [9.9] -3 SIZE 3 FITTING FS--XX / NPTF MALE 0.97 [.6].50 [38.] FS500 FILTER DISK 0.87 [.] FLOW :6 0 EDCO USA.

7 RELEASE CHECK RC8A The RC8A employs a normally closed valve to seal against pump vacuum without leaking. When a compressed air supply is applied, the release valve shifts open at only 5 psi (0.3 bar) so that a full-flow burst of air can quickly dissipate (blow-off) system vacuum. Once shifted, the valve doesn t try to close, but remains open. Once the compressed air source is removed it automatically resets to a closed position. The RC8A should be used for high-flow vacuum release applications such as those involving vacuum reservoirs or larger single-stage or multi-stage vacuum pumps. Competitive products are simply check valves with a 30-0 psi (-3 bar) cracking pressure. The high cracking pressure is necessary to insure a tight seal against vacuum developed by the pump. When a compressed air supply is applied to open the valve for blow-off, the internal spring immediately tries to close the valve as soon as flow begins. This has the effect of subtracting the valve cracking pressure from the blow-off air pressure. Because of this these systems normally have to operate above 50 psi (3.3 bar), which wastes compressed air. 50 psi Maximum Pressure Weight:.07 lbs. (8.5g) 0.55 [] 0.3 [7.6] 0.98 [.9] Release Air 5 psi Minimum 0.5 [.7] 0. [.5].63 [.] O-ring Seal 0. [.8] Compressed Air RC8A RC8-00A The RC8-00A operates the same as the RC8A but includes a 0 in. ( mm) balancing orifice to meter the air flow when multiple Release Checks are supplied air from the same blow-off control valve. Without the balancing orifice in each release check, the air would follow the path of least resistance. This would starve some release valves of air while others would have a flow many times greater than necessary [] 0.3 [7.6] 0.98 [.9] Release Air 5 psi Minimum 0.5 [.7] 0. [.5].63 [.] O-ring Seal 0. [.8] 50 psi Maximum Pressure Weight:.07 lbs. (8.5g) Compressed Air RC8-00A in..0 mm Orfice 0 EDCO USA. :7

8 ACUUM CHECK The acuum Check valve is designed to prevent the reverse flow of ambient air into a vacuum system. acuum Check valves are used to hold vacuum downstream whenever the vacuum source is removed or lost. Internally, a normally closed valve allows vacuum flow in the pump direction, but seals off when vacuum flow ceases. When a vacuum check valve is used in a system, some provision must be made to release the trapped vacuum in order to release the work piece. The RC8 and RC8-00 release check valves are designed for this purpose. One application for the acuum Check valves is for energy saver circuits using a vacuum storage tank to accumulate and store vacuum for highvolume, short duration, flow rate requirements. dropped if the system s vacuum source is lost. The vacuum trapped by the acuum Check will eventually leak down. The rate at which the vacuum diminishes will depend on the condition of all the components in the vacuum system. To increase the time delay interval, a volume chamber can be added to the auxiliary port. If the volume chamber is equal to twice the cup internal volume, the time delay interval will be approximately tripled, and so forth. The C8 should be used with cup diameters of 50mm and smaller. The C should be used with cup diameters of 75mm and larger that are available with G/ NPS female fittings [.] More commonly, a vacuum check valve with release check valve would be used with a single suction cup so a nonporous, high value work piece would not be immediately C8 0.8 [.].80 [5.7].60 [0.6].36 [3.5] 0.8 [.6] THRU PLACES 0.63 [6] acuum Source 0.8 [.6] 0.99 [5.].6 [9.5] 0.8 [.] A 0.8 [.] A 0.7 [.9].8 [3.5] Weight:.5 lbs. (68g) C Weight:.9 lbs. (86g) acuum Source A A. [56.]. [3] G/ NPSF 0.6 [5.5] 0.63 [5.9] A A O-ring Seal G/ NPSF 0.98 [.9] :8 0 EDCO USA.

9 ACUUM CHECK WITH RELEASE CHECK The acuum Check valve with Release Check is used with a single suction cup so a non-porous, high value work piece won t be immediately dropped if the system vacuum source is lost. The vacuum trapped by the acuum Check will eventually leak down. The rate at which the vacuum diminishes will depend on the condition of all the components in the vacuum system. To increase the time delay interval, a volume chamber can be added to the auxiliary port. If the volume of the chamber is twice the internal cup volume, the time delay interval will be approximately tripled, and so forth. See Page :7 for RC00A description. C8 RCA, C8 RC00A.3 [58.9].79 [70.9].6 [9.5].8 [30].63 [.].80 [5.7] 0.98 [.9] 0.8 [.6] 0.7 [.3] 0.63 [6] 0.3 [5.8].3 [58.9] acuum Source 3 RC8-00A in..0 mm Orfice Compressed Air Blow-off Air 5psi (0.3bar) min. 3 0 EDCO USA. :9

10 ACUUM CHECK WITH RELEASE CHECK C RCA, C RC00A G/ NPSF. [53.8]. [3]. [56.] G/ NPSF 0.98 [.9] 0.63 [6] O-ring Seal 0.3 [5.8] acuum Source RC8-00A A 3 A in..0 mm Orfice Compressed Air Blow-off Air 5psi (0.3bar) min. 3 LOW-PROFILE CONE ALES HOW TO ORDER CUP CUP SIZE MATERIAL XP - F 50 N - 8F - C F30 30 = 30mm A = Ameriflex 8M = G/8 NSF Male, 0 = 0mm D = Duramax 30mm Only 50 = 50mm N = Nitrile 8F = G/8 NSF Female, Male S = Silicone 0 & 50mm Only = iton F0 FITTING Female All cups are available in Nitrile and Silicone. Check availability for other materials before ordering. F50 Female :0 0 EDCO USA.

11 MECHANICAL ALE B0, B50 & B50 M M6X /8-7 NPSF CUP SIZE XP - B0 N - 6X0M 0 = 0 mm N = Nitrile 50 = 50 mm S = Silicone B50 50 = 50 mm CUP MATERIAL = iton For overall height, refer to dimensions for selected cup...38 [35.].30 [58.] X JN-M6X 5 [.3] M-B0 G/ NPS CUP SIZE CUP MATERIAL XP - B0 N - F - M 0 = 0 mm N = Nitrile S = Silicone = iton.5 [3] HEX.0 [55.9] [.5] M-F75 CUP SIZE CUP MATERIAL G/ NPS XP - F75 N - F - M 75 = 75 mm N = Nitrile S = Silicone = iton [] M-F0 & M-F50 CUP SIZE CUP MATERIAL XP - F0 N - F - M 0 = 0 mm N = Nitrile 50 = 50 mm S = Silicone = iton.5 [3] HEX.6 [3] G/ NPS ADJUSTABLE PROJECTION [] 0 EDCO USA. :

12 SWIEL JOINTS 30 G/ NPS 30 / NPTF 30 /8 NPTF.75 [.5].7 [3.3].7 [3.3] G/ NPS G/ NPS G/ NPS SJ SJ-M SJ-8M G / NPS Swivel Joint For use with 75mm to 50mm cups. Brass body, stainless steel shaft, nitrile seals. Weight: 0.3 (5g) 30.3 [8.7] TEE ADAPTORS 5/6-8 UNF TA8 G /8 NPS Swivel Joint For use with 0mm to 50mm cups. Brass body, stainless steel shaft, nitrile seals. Weight: 9 (g) SJ8 Mounts any suction cup having a female fitting and allows daisy chaining vacuum tubing from cup to cup to simplify plumbing. A plug is provided so the TA can also be used as an angle adaptor to allow vacuum lines to be routed perpendicular to the suction cup axis. 0.3 [5.8] REMOABLE /8 NPT PLUG 0.60 [5.]. [8.].35 [3.3] 3/8-6 UNC (TA-38) OR 5/6-8 UNC (TA) REMOABLE G/ NPSF PLUG TA & TA [.] G/8 NPS Construction: Anodized Aluminum WEIGHT: (9.9g) 0.6 [5.7] G/ NPS. [5.].08 [7.] Construction: Zinc Chromate WEIGHT: 0. (95g).00 [5.].6 [3] : 0 EDCO USA.

VACUUM CUPS 2 SECTION 2 VACUUM CUPS 2: EDCO USA.

VACUUM CUPS 2 SECTION 2 VACUUM CUPS 2: EDCO USA. VACUUM S SECTION VACUUM S 01 EDCO USA. www.edcousa.net :1 VACUUM S CONTENTS BELLOWS S (B) DOUBLE BELLOWS S (B) BELLOWS TRACTION FOOT S (BF) MULTI-BELLOWS S (BL) DEEP S (D) FLAT S (F) FLAT CONCAVE S (FC)

More information

SECTION 6 VACUSTAT, PRESSURE SENSORS, VACUUM SENSORS, & FILTERS

SECTION 6 VACUSTAT, PRESSURE SENSORS, VACUUM SENSORS, & FILTERS SYSTEM ACCESSORIES SECTI 6 VACUSTAT, PRESSURE SENSORS, VACUUM SENSORS, & FILTERS 6 2012 EDCO USA. www.edcousa.net 6:1 6 SYSTEM ACCESSORIES CTENTS VACUSTAT MECHANICAL PRESSURE SWITCH INLINE VACUUM FILTER

More information

SECTION 7 AX SERIES PUMPS

SECTION 7 AX SERIES PUMPS SECTION X SERIES PUMPS EDCO US www.edcousa.net : X PUMPS Z - ZERO BSE G /8 NPSF G / NPSF LRGE CPCITY G / NPSF General Information : Z: Zero Base (No Base) :4 G/8 NPSF Bases :5 - :6 G/ NPSF Bases : - :

More information

Catalog 080-/USA Notes Vacuum Control Valves

Catalog 080-/USA Notes Vacuum Control Valves Vacuum Control Valves Section Catalog 080-/USA Notes Vacuum Control Valves Catalog 080-/USA Index Vacuum Control Valves VA0 Vacuum Control Valves for Centralized Vacuum Systems VA0PSV & VA0PSP, -Port,

More information

Colorflow and Ball Valves. Industrial Flow Control, Check, Gauge Control. Catalog HY /US

Colorflow and Ball Valves. Industrial Flow Control, Check, Gauge Control. Catalog HY /US Colorflow and Industrial Flow Control, Check, Gauge Control Catalog HY14-3300/US Colorflow and Fully guided poppets are used on Colorflow valves rather than the less durable ball-check type construction.

More information

Valves. E Valves. Multiple Hydraulic System Applications

Valves. E Valves. Multiple Hydraulic System Applications s Multiple Hydraulic System Applications Parker Check s are unidirectional flow control devices used primarily in hydraulic systems to eliminate potential damage caused by fluid back pressure. Offered

More information

Catalog Hydraulic Couplings High Pressure

Catalog Hydraulic Couplings High Pressure High Pressure 3 Series Threaded Actuation Design Threaded Sleeve The 3 Series coupling are designed for high pressure applications. The coupler sleeve and nipple body must be manually threaded together

More information

Vacuum Filters. Catalogue Edition 2

Vacuum Filters. Catalogue Edition 2 Vacuum Filters Catalogue Edition 2 INLINE VACUUM FILTERS Vacuforce plastic in-line filters provide easy monitoring, economy and safety. These shatterproof filters are 100% airtight, can withstand high

More information

AIR RIDE SUSPENSION SYSTEMS

AIR RIDE SUSPENSION SYSTEMS AIR RIDE SUSPENSION SYSTEMS Solenoid Valves (Fast Valves) Valve Manifold Systems Pressure Switches Filters (Water Traps) Air Bellows & Fittings www.asconumatics.com 1 ASCO Numatics Air Ride Components

More information

Check Valves, Filters and Relief Valves

Check Valves, Filters and Relief Valves Check Valves, Filters and Relief Valves Catalog 4135-CV December 2010 Series Check Valves Catalog 4135-CV Introduction Parker Series Check Valves are designed for uni-directional flow control of fluids

More information

FIT-2. Inch. Ø Â" to Ë" O/D tube

FIT-2. Inch. Ø Â to Ë O/D tube For simple and quick assembly of pneumatic circuits. Positive tube connection. Wide range of types available. Reliable and corrosion resistant. Specifications Fluid: Compressed air, nitrogen, inert and

More information

Model Model Model

Model Model Model Filter Separators Model 9003 Model 9004 Model 9001 & 9032 Model 9002 EXAIR's Filter Separators remove water, dirt and rust from your compressed air system. They prevent these contaminants from plugging

More information

AIR DRIVEN HIGH PRESSURE HYDRAULIC PUMPS & POWER UNITS

AIR DRIVEN HIGH PRESSURE HYDRAULIC PUMPS & POWER UNITS AIR DRIVEN HIGH PRESSURE HYDRAULIC PUMPS & POWER UNITS . orporated was formed in California to specialize in the supply of air driven high pressure hydraulic pumps and power units to customers located

More information

Pressure Sensor No Series

Pressure Sensor No Series Sales Manual Section 335 PRODUCT SPECIFICATION 84372 SERIES Pressure Sensor No. 84372-Series GENERAL DESCRIPTION The patented* No. 84372-Series Pressure Sensor contains a weatherproof, snap-acting valve

More information

Model Model 815

Model Model 815 Model 600004 Model 600204 Model 85387 Model 600104 Model 815 ir line products and accessories ir couplers and nipples............................... 196 low guns, tire inflators and siphon sprayers.............

More information

CXL2 Injectors & Manifolds

CXL2 Injectors & Manifolds CXL2 Injectors & Manifolds Premium Single Line Grease Systems General Designed for use in single line high pressure automatic grease systems, CXL2 Injectors deliver precise volumes of lubricant at predetermined

More information

LEAK TEST PROCEDURE MRTALPCH611LDC REMOTE READY LIFTERS W/ 3 BUTTON CONTROL APPLICABLE TO LIFTERS WITH SERIAL NUMBERS GREATER THAN #

LEAK TEST PROCEDURE MRTALPCH611LDC REMOTE READY LIFTERS W/ 3 BUTTON CONTROL APPLICABLE TO LIFTERS WITH SERIAL NUMBERS GREATER THAN # LEAK TEST PROCEDURE MRTALPCH611LDC REMOTE READY LIFTERS W/ 3 BUTTON CONTROL APPLICABLE TO LIFTERS WITH SERIAL NUMBERS GREATER THAN # 20100742 TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON

More information

Schroeder Check Test Point System

Schroeder Check Test Point System Section 1: Introduction Schroeder Check test points provide a fast easy and safe way to test pressures up to 10,000 psi (680 bar) in hydraulic systems under operation. They are available in both 1620 (M16x20)

More information

Temperature Sensor Series

Temperature Sensor Series GENERAL DESCRIPTION The patented* No. 85026-Series Temperature Sensor contains a two-position valve operated by temperature variations around the integral sensing bulb. It is used to vent or block a pneumatic

More information

Valves, Fittings, and Manifolds Catalog. We make things MOVE

Valves, Fittings, and Manifolds Catalog. We make things MOVE Valves, Fittings, and Manifolds Catalog We make things MOVE We Make Things Move A forward-thinking innovator, Bimba provides industry-leading pneumatic, hydraulic and electric motion solutions that are

More information

VFDAVV 1/2 VFDAVV VACUUM VALVES. DIMENSIONS (mm)

VFDAVV 1/2 VFDAVV VACUUM VALVES. DIMENSIONS (mm) VACUUM VALVES VFDAVV VACUUM VALVES Direct acting vacuum valves 12VDC, 24VDC, 110VAC & 230VAC 1/4 & 1/2 Ports Full size high flow orifice 3-way Operation 2-way Operation (plug exhaust port using VFBP-U02)

More information

Manufacturers of Premium Pneumatic Controls since 1921 ROSS CONTROLS ROSS CONTROLS ROSS CONTROLS

Manufacturers of Premium Pneumatic Controls since 1921 ROSS CONTROLS ROSS CONTROLS ROSS CONTROLS Manufacturers of Premium Pneumatic Controls since 1921 ROSS CONTROLS ROSS CONTROLS ROSS CONTROLS New Product Introduction 400 PSI High Pressure Regulator Ports: 1/8, 1/4, 3/8 Problem: Most spring activated

More information

HWB Series GENERAL PUMP. Hydraulic Drive Triplex Plunger Pump INDUSTRIAL INDUSTRIAL FEATURES

HWB Series GENERAL PUMP. Hydraulic Drive Triplex Plunger Pump INDUSTRIAL INDUSTRIAL FEATURES GENERAL PUMP HWB Series Hydraulic Drive Triplex Plunger Pump FEATURES INDUSTRIAL INDUSTRIAL Innovative drive design eliminates need for auxiliary hydraulic drive Forged brass manifold Built-in Pump Thermal

More information

MODIFICATIONS AVAILABLE - MADE TO ORDER - CONSULT OUR FACTORY. (MINIMUM ORDER MAY BE REQUIRED.)

MODIFICATIONS AVAILABLE - MADE TO ORDER - CONSULT OUR FACTORY. (MINIMUM ORDER MAY BE REQUIRED.) NEEDLE VALVES - ANGLE & CROSS PATTERN Flow can be accurately controlled from full orifice opening to shut off. Fluid flow is readily visible through large sight window. Cross pattern can be used singularly

More information

Check Valve AP64 P.149. Vacuum Generator Vacuum Generator Module Vacuum Generator Module AP7 & 70 AP71 AP72. Flow Switch Flow Switch (For high flow)

Check Valve AP64 P.149. Vacuum Generator Vacuum Generator Module Vacuum Generator Module AP7 & 70 AP71 AP72. Flow Switch Flow Switch (For high flow) Check Valve eries Check Valve AP64 P.149 Vacuum Generator Vacuum Generator Vacuum Generator Module Vacuum Generator Module Flow witch Flow witch Flow witch (For high flow) eries AP7 & 7 AP71 AP72 eries

More information

Purging Air From Divider Block Lubrication Systems

Purging Air From Divider Block Lubrication Systems FROST ENGINEERING SERVICE Purging Air From Lubrication Systems A D I V I S I O N O F G E C S E Y S A L E S & S E R V I C E DESCRIPTION Divider block lubrication systems operate correctly only when all

More information

A Filtration Primer. Filter Elements. High Pressure Filters. Tank-Mounted, Return Line and Medium Pressure Filters. Water Service Filters

A Filtration Primer. Filter Elements. High Pressure Filters. Tank-Mounted, Return Line and Medium Pressure Filters. Water Service Filters A Filtration Primer Filter Elements High Pressure Filters Tank-Mounted, Return Line and Medium Pressure Filters Water Service Filters Section 6 Reservoir Accessories SCHROEDER INDUSTRIES 259 Principles

More information

HYDROSTATIC TEST SYSTEM MANUAL

HYDROSTATIC TEST SYSTEM MANUAL PDQC HYDROSTATIC TEST SYSTEM MANUAL Technical Specification Operating Instructions Part List Revised 12-2016 Manual # PDQC- 6,000 And PDQC-10,000 1 PDQC PERFORMANCE DATA Model Number Maximum Pressure Volume

More information

Cylindrical Pumps. J-Series Cylindrical Venturi Pumps

Cylindrical Pumps. J-Series Cylindrical Venturi Pumps J-Series Cylindrical Venturi Pumps The J-Series Venturi Vacuum Pumps utilize a fixed cartridge venturi design. J-Series pumps employ a cylindrical design for ease of installation and mounting into in-line

More information

Air Preparation Products. For Low Temperature Service. Parker Hannifin Corporation Pneumatic Division Richland, Michigan

Air Preparation Products. For Low Temperature Service. Parker Hannifin Corporation Pneumatic Division Richland, Michigan Air Preparation Products For Low Temperature Service Catalog -E Miniature R Series R Regulators Miniature Miniature Regulators /8", /" Basic /8" Body R-C Non- R-MC Features Diaphragm operated for fast

More information

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM Hydraulic Symbol MF 80/85/160/180 MF 90/95/190/195 A A (Standard) (Suction) B B Features MF Filters are manufactured with an aluminum head. Choice

More information

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM Hydraulic Symbol MF 80/85/160/180 MF 90/95/190/195 A A (Standard) (Suction) B B Features MF Filters are manufactured with

More information

Check Valves (C Series) Catalog 4130-C Revised, July 2004

Check Valves (C Series) Catalog 4130-C Revised, July 2004 Check Valves (C Series) Catalog 4130-C Revised, July 2004 Introduction Parker C Series Check Valves are designed for uni-directional flow control of fluids and gases in industries such as chemical processing,

More information

SERIES. CRYOGENIC/PRESSURE BUILD REGULATOR 3/8 and 1/2" NPT, BSPT Inlet 400 Psig (28 Bar) Description

SERIES. CRYOGENIC/PRESSURE BUILD REGULATOR 3/8 and 1/2 NPT, BSPT Inlet 400 Psig (28 Bar) Description CRYOGENIC/PRESSURE BUILD REGULATOR 3/8 and 1/2" NPT, BSPT Inlet 400 Psig (28 Bar) CR Description The Generant Series CR Cryogenic Regulator provides high flow during Cryogenic Vessel Pressure Build function

More information

FULL COLOR TAB #12 BTP

FULL COLOR TAB #12 BTP FULL COLOR TAB #12 BTP 216 HEAVY DUTY BENCH PRESS BTP - How to MODEL: BTP-501 FOR SINGLE PISTON ROD, 5.00 BORE, MF1 MOUNT CYLINDERS Heavy Duty Bench Top Press shown with 5.00 Bore three (3) Stage Multi-Stage

More information

Left: Custom EOAT spring levelers, vacuum fitting and cup assembly. Right: Vacuum fitting and Vacuum cup. Ø D E B VCF1-1032M

Left: Custom EOAT spring levelers, vacuum fitting and cup assembly. Right: Vacuum fitting and Vacuum cup. Ø D E B VCF1-1032M Vacuum up Fittings Ideal pplications: utomation assembly fixtures Robotic end effectors nd-of-rm Tooling devices Left: ustom OT spring levelers, vacuum fitting cup assembly. Right: Vacuum fitting Vacuum

More information

BTPSeries. BenchTopPress. Cylinders 95% OFOURCYLINDERSSHIPIN2-3DAYS! ONEDAYRUSHSERVICEAVAILABLEONALLCATALOGEDCYLINDERMODELS!

BTPSeries. BenchTopPress. Cylinders 95% OFOURCYLINDERSSHIPIN2-3DAYS! ONEDAYRUSHSERVICEAVAILABLEONALLCATALOGEDCYLINDERMODELS! BTPSeries BenchTopPress& BenchTopPress Page196 Press Page199 95% OFOURCYLINDERSSHIPIN2-3DAYS! ONEDAYRUSHSERVICEAVAILABLEONALLCATALOGEDCYLINDERMODELS! HEAVY DUTY BENCH PRESS BTP - How to MODEL: BTP-501

More information

Low Pressure Filters. Low Pressure Filters LOW PRESSURE FILTERS

Low Pressure Filters. Low Pressure Filters LOW PRESSURE FILTERS Low Pressure Filters Low pressure filters are the most common type of filter found in hydraulic circuits used most often in return line applications. Low Pressure Filters Donaldson low pressure filters

More information

Quick Coupling Products

Quick Coupling Products Quick Coupling Products Quick Couplings, Swivels, Valves, Diagnostic Equipment Catalog 38 USA February 14 Locations Grantsburg, WI Chetek, WI Union City, PA FAILURE OR IMPROPER SELECTION OR IMPROPER USE

More information

Inline Adapters are Electro Polished to 10 Ra Max. 2 Valves supplied with Metal to Metal Face Seal connections have

Inline Adapters are Electro Polished to 10 Ra Max. 2 Valves supplied with Metal to Metal Face Seal connections have CRYOGENIC RELIEF VALVE (STAINLESS) 1/4" and 1/2" NPT -4 and -8 Metal To Metal Face Seal 1/4" and 1/2" Bi-Lok Dual Ferrule Tube 10-750 Psig (0.69-51.7 Bar) STAINLESSCRV Description The Generant Series Stainless

More information

CVH103P. Check Valve Series CVH103P. Technical Information. General Description

CVH103P. Check Valve Series CVH103P. Technical Information. General Description Catalog HY-351/US Information Cartridge Style Valve. For additional information see Tips on pages 1-4. Valve Series H13P Spherical poppet for low leakage D -Ring eliminates back-up rings Dual sense paths

More information

Vacuum Generators. Catalogue Edition 2

Vacuum Generators. Catalogue Edition 2 Vacuum Generators Catalogue Edition 2 Switch Options S = SK = The fixed switch option is normally open and changes position at 12 Hg The adjustment of the SK model switch is between 6-16 Hg Features: Anodized

More information

1/8 NPT (F) 1/8 NPT (F)

1/8 NPT (F) 1/8 NPT (F) Control Valves & Valve Accessories PNEUMADYNE, INC. Catalog 400 Phone 76-559-077 Fax 76-559-0547 Features l Compact size (.5 OAL) l 4 Porting configurations l High flow l Single stem design l Plumbing

More information

Check Valves (CO Series) Catalog 4130-CO Revised, June 2001

Check Valves (CO Series) Catalog 4130-CO Revised, June 2001 Check Valves (CO Series) Catalog 4130-CO Revised, June 2001 Introduction Parker are designed for uni-directional flow control of fluids and gases in industries such as chemical processing, oil and gas

More information

FLOW CONTROLLERS Instrument/Analyzer Products. Catalog 4513/USA April 2003

FLOW CONTROLLERS Instrument/Analyzer Products. Catalog 4513/USA April 2003 FLOW CONTROLLERS Instrument/Analyzer Products Catalog 4513/USA April 2003 FLOW CONTROLLERS Instrument/Analyzer Products Catalog 4513/USA April 2003 table of contents SC420 Series............. 1-2 SC423XL

More information

EVP SERIES PROPORTIONAL CONTROL VALVES

EVP SERIES PROPORTIONAL CONTROL VALVES EVP SERIES PROPORTIONAL CONTROL VALVES 207 Clippard is pleased to add the EVP series proportional control valve to our electronic product line. This product combines the features of the existing EV series

More information

Flow Limit Safety Shutoff Valves Model 1

Flow Limit Safety Shutoff Valves Model 1 Flow Limit Safety Shutoff Valves Model 1 Model 1 Series flow limit safety shutoff valves automatically shutoff all flow from the cylinder when flow exceeds a factory preset level. The Model 1 is normally

More information

Control Valves & Valve Accessories

Control Valves & Valve Accessories Control Valves & Valve Accessories PNEUMADYNE, INC. Catalog 400 Phone 76-559-077 Fax 76-559-0547 Stainless Steel 0- Fully Ported valve with M5 threads available- contact factory Viton is a registered trademark

More information

Function Fittings. Flow Control Regulators. Piloted Function Fittings. Non-Return Valves. LIQUIfit Pressure Fittings. Other Function Fittings

Function Fittings. Flow Control Regulators. Piloted Function Fittings. Non-Return Valves. LIQUIfit Pressure Fittings. Other Function Fittings Flow Control Regulators Piloted Non-Return Valves LIQUIfit Pressure Fittings Other Silencers Flow Control Regulators (P. 4-6) Blocking Fittings (P. 4-36) Piloted Non-Return Valves (P. 4-38) Function:

More information

Introduction Parker are designed for uni-directional flow control of fluids and gases in industries such as chemical processing, oil and gas productio

Introduction Parker are designed for uni-directional flow control of fluids and gases in industries such as chemical processing, oil and gas productio Check Valves (C Series) Catalog 4130-C Revised, July 2004 Introduction Parker are designed for uni-directional flow control of fluids and gases in industries such as chemical processing, oil and gas production

More information

2003 Mustang Workshop Manual

2003 Mustang Workshop Manual Page 1 of 6 SECTION 412-03: Air Conditioning 2003 Mustang Workshop Manual DESCRIPTION AND OPERATION Procedure revision date: 06/14/2002 Air Conditioning Printable View (225 KB) The A/C refrigerant system

More information

Fisher 2506 and 2516 Receiver Controllers

Fisher 2506 and 2516 Receiver Controllers 2506/2516 Receiver Controllers Product Bulletin Fisher 2506 and 2516 Receiver Controllers The 2506 receiver controller takes the input from a pneumatic transmitter, matches it against the adjustable set

More information

Introduction Parker are designed for uni-directional flow control of fluids and gases in industries such as chemical processing, oil and gas productio

Introduction Parker are designed for uni-directional flow control of fluids and gases in industries such as chemical processing, oil and gas productio Check Valves (CO Series) Catalog 4130-CO Revised, June 2001 Introduction Parker are designed for uni-directional flow control of fluids and gases in industries such as chemical processing, oil and gas

More information

PT Series Tank Top Filters

PT Series Tank Top Filters Tank Top Filters 9 Applications Together we can Preserve the environment. Minimize waste and promote energy efficiency. Achieve worldwide filtration solutions. Build global confidence. Redefine new limits.

More information

GENERAL PUMPA member of the Interpump Group

GENERAL PUMPA member of the Interpump Group FEATURES Innovative drive design eliminates need for auxiliary hydraulic drive HWB Series Hydraulic Drive - Triplex Plunger Pump HWB2512 & HWB2112 Forged brass manifold No scheduled maintenance required

More information

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The MPV1 series valve uses Proportion- Air closed loop technology for pressure control. It gives an output pressure proportional

More information

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The MPV1 series valve uses Proportion- Air closed loop technology for pressure control. It gives an output pressure proportional

More information

Available with T93R MAXX Tip & Guard

Available with T93R MAXX Tip & Guard 7500 PSI (500 BAR) Maximum Pressure Airless Gun High-strength aluminum alloy handle is light-weight, solid and strong single piece forging that features an anodized protective finish that is highly corrosive

More information

Catalog Pnuematic Couplings

Catalog Pnuematic Couplings Industrial Interchange Nipples A-A-59439, MIL- C-4109F Design Non-valved, straight through Pioneer Industrial Interchange Nipples are compatible for use with 20 Series, HF Series, Universal or E-z-mate

More information

Oil and Gas Products Pressures to 30,000 psi

Oil and Gas Products Pressures to 30,000 psi Oil and Gas Products MAXIMATOR has been designing and manufacturing specialty products to the high pressure market for over thirty years and has a worldwide reputation for quality and reliability. Oil

More information

VFC-5 to VFC-500 FLO-COATER

VFC-5 to VFC-500 FLO-COATER VFC-5 to VFC-500 FLO-COATER OPERATION INSTRUCTIONS Page -1- CONTENTS PAGE NUMBER System Description... 2 Flo-Coater Description... 4 Operation of a Flo-Coater... 8 Selective Operator Control... 9 Operating

More information

Instrument Valves and Manifolds

Instrument Valves and Manifolds Instrument Valves and Manifolds Needle Valves Instrument Valve Orifice Block Valves Gauge Block Valves Block & Bleed Valves Integral Block & Bleed Valves Two Valve Manifolds Three Valve Manifolds Five

More information

Low Pressure Filters

Low Pressure Filters MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM Hydraulic Symbol /80/85/160/180 MF 90/95/190/195 A A B B Features MF Filters are manufactured with an aluminum head. Choice of NPT, SAE straight

More information

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) Features MF Filters are manufactured with an aluminum head. MF, MFD, MFDS Series Spin-On Filters Choice of NPT, SAE straight thread O-ring boss, BSPP, and SAE 4-bolt flange porting to allow easy installation

More information

GPS AutoSteer System Installation Manual

GPS AutoSteer System Installation Manual GPS AutoSteer System Installation Manual Supported Vehicles Case IH Combines 7010 7120 8010 8120 AFX 8010 9120 PN: 602-0283-01-A LEGAL DISCLAIMER Note: Read and follow ALL instructions in this manual carefully

More information

Vacuum Level. Max Vacuum -Kpa / Hg. Model A B C D E F G H ØI Supply Vacuum Exhaust CV05H / SK CV10H / SK

Vacuum Level. Max Vacuum -Kpa / Hg. Model A B C D E F G H ØI Supply Vacuum Exhaust CV05H / SK CV10H / SK VACUUM VENTURI CV VACUUM VENTURI Anodized aluminum body All metal construction Maximum vacuum of 27 Hg Vacuum flow rates up to 8CFM Single stage technology HSK s include part presence switch R N CV 15

More information

Rotary Plug Valves (PR Series) Catalog 4126-PR Revised, July 2003

Rotary Plug Valves (PR Series) Catalog 4126-PR Revised, July 2003 Rotary Plug Valves (PR Series) Catalog 4126-PR Revised, July 2003 PR Series Rotary Plug Valves Introduction Parker PR Series Plug Valves provide positive leak tight shut-off, high flow capacity, and quick

More information

Parallel Grippers- DPDS DIRECTCONNECT Modular Series

Parallel Grippers- DPDS DIRECTCONNECT Modular Series Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (8) 426-548 www.cmafh.com 1.134 Parallel Grippers- DPDS DIRECTCONNECT Modular Series Mounting Information: Grippers

More information

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION The QB4 is a closed loop electronic pressure regulator consisting of two solenoid valves, an internal pressure transducer,

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 6 1. DESCRIPTION The Viking Model D-2 Accelerator is a quick-opening device, with an integral anti-flood assembly, used to increase the operating speed of a differential type dry pipe valve.

More information

CASH VALVE K SERIES BACK PRESSURE VALVES

CASH VALVE K SERIES BACK PRESSURE VALVES High capacity angle bypass regulators or back pressure control valves with models for pressures to 1500 psig (103.4 barg) and capacities to 200 gallons per minute (757 l/min.) FEATURES GENERAL APPLICATION

More information

Warnings and Cautions

Warnings and Cautions Warnings and Cautions WARNINGS: APPLICATION 1. ARO valves are designed for use only in industrial pneumatic (air) and / or vacuum systems applications and are NOT to be used for individual consumer use,

More information

Check Valves Product Specs and Ordering SINGLE BALL STEEL CHECK VALVES. Specifications. Operation. Features

Check Valves Product Specs and Ordering SINGLE BALL STEEL CHECK VALVES. Specifications. Operation. Features SINGLE BALL STEEL CHECK VALVES Single Ball Steel Check Valves are designed for use in hydraulic or lubrication systems with pressures up to 5,000 PSI. Available in two models for use as inlet or outlet

More information

Flow Computer Installation

Flow Computer Installation Flow Computer Installation WARNING: Only personnel who are experienced with field wiring should perform these procedures. All field wiring must conform to the National Electrical Code, NFPA 70, Article

More information

KOBOLD DF-WM Flow Monitor. User Instructions

KOBOLD DF-WM Flow Monitor. User Instructions KOBOLD DF-WM Flow Monitor User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com Manual-DF-WM_12-13 DF-WM Table

More information

VC & VPC Series Check Valves

VC & VPC Series Check Valves VC & VPC Series Check Valves Up to 10 000psig (689 bar), Steel, and Brass Catalog No. VC-4 July 2015 Design VC and VPC Series Check Valves are designed to prevent reverse flow and keep the fluid in one

More information

Product Catalog. Fittings ½ AIR PIPE FITTINGS Fitting, 1/2 Air Pipe End Cap Coupler, with Tank Valve

Product Catalog. Fittings ½ AIR PIPE FITTINGS Fitting, 1/2 Air Pipe End Cap Coupler, with Tank Valve To complement our extensive line of cable pressurization products, System Studies also sells a variety of air pipe and pressure tube fittings. This section of the catalog describes these commonly used

More information

Table of Contents. SeaTechInc.com

Table of Contents. SeaTechInc.com Table of Contents 1-2 Technical Information 3 Tubing for 35 Series 4-5 10 Series Fittings 6-11 35 Series Fittings and Valves 12 35 Series Quick Connect Manifold, Configuration Styles 13 35 Series Quick

More information

Fluid Power Accessories

Fluid Power Accessories Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca. 93308 661-399-9569 fax 661-393-9654 PNEUMATIC EXHAUST MUFFLERS Breather Vents 2,3 Exhaust Mufflers 2-5 Reclassifiers / Mufflers 6,7 BREATHER VENTS Speed

More information

Industry Standouts for Over 50 Years

Industry Standouts for Over 50 Years » Pneumatic Products » Industry Standouts for Over 50 Years The benefits of an innovative, pneumatic coupling design were solid enough to single-handedly launch CEJN in 1955. This reliable, easy-to-handle

More information

2003 Explorer Sport/Sport-Trac Workshop Manual. 7. Disconnect the vacuum harness connector. Remove the nut.

2003 Explorer Sport/Sport-Trac Workshop Manual. 7. Disconnect the vacuum harness connector. Remove the nut. 7. Disconnect the vacuum harness connector. Remove the nut. 8. Remove two nuts, one bolt, and the A/C evaporator housing (19850). Remove the nut located at the bottom of the A/C evaporator housing first.

More information

Marine Fuel Filtration Marine 800 Series

Marine Fuel Filtration Marine 800 Series Racor recyclers offer large diesel engine operators both ease of maintenance and continuous engine operation. Continuous operations include filter changeouts and the draining of accumulated water from

More information

Fittings Metal Push-To- Connect Fittings. We make things MOVE

Fittings Metal Push-To- Connect Fittings. We make things MOVE Fittings Metal Push-To- Connect Fittings We make things MOVE Contents 3 Fittings 4 Product Features 4 Push-In Fittings 4 Features and Benefits 5 How it Works 5 Materials of Construction 5 Fluid 5 Operating

More information

D5 & 10-5 SERIES AIR OPERATED LIQUID PUMPS

D5 & 10-5 SERIES AIR OPERATED LIQUID PUMPS D & 1- SERIES AIR OPERATED LIQUID PUMPS PRESSURE RATIO OLD & NEW PART NUMBERS In the mid 199 s with the advent of a new inventory and computer system, SC Hydraulic Engineering was forced to change the

More information

DESCRIPTION MECHANICAL FUEL PUMP FUEL FILTER HIGH PRESSURE (35-90 PSI) HIGH PRESSURE (35-90 PSI) (STEEL/INCLUDED)

DESCRIPTION MECHANICAL FUEL PUMP FUEL FILTER HIGH PRESSURE (35-90 PSI) HIGH PRESSURE (35-90 PSI) (STEEL/INCLUDED) Edelbrock EFI Universal Fuel Sump System - Adjustable Part #36031, 36032, 36033, 36034 INSTALLATION INSTRUCTIONS PLEASE study these instructions carefully before beginning this installation. This installation

More information

DPS280 / DVS280 Series

DPS280 / DVS280 Series 1 2 3 4 5 6 7 8 Do not use corrosive or flammable gases or liquid with this product. Please use within the rated pressure range. Do not apply pressure beyond recommended maximum pressure, permanent damage

More information

AUTOMATIC CONTROL VALVES BY RAPHAEL

AUTOMATIC CONTROL VALVES BY RAPHAEL CONTROL VALVES AUTOMATIC CONTROL VALVES BY RAPHAEL RAF PRESSURE RAF PRESSURE offers the possibility of controlling an upstream pressure, a downstream pressure or both. RAF PRESSURE REDUCING reduces and

More information

TUBES CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBES

TUBES CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBES ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Nylon Tubes, 489 Soft Nylon Tubes, 490 Urethane Tubes, 491 Flat Tubes,, Handling Instructions and Precautions

More information

Flow Control Valves Check Valves Gauge Control Valves. Colorflow Valves

Flow Control Valves Check Valves Gauge Control Valves. Colorflow Valves Check Valves Gauge Control Valves Colorflow Valves Colorflow and Ball Valves Industrial Flow Control, Check, Gauge Control Catalog HY14-3300/US Colorflow and Ball Valves Fully guided poppets are used on

More information

Performance Data. Temperature Range. -20 o to 160 o F 26 Hg to 125 psi. C v Flow Rate (scfm) Fill Time Exhaust. Port.

Performance Data. Temperature Range. -20 o to 160 o F 26 Hg to 125 psi. C v Flow Rate (scfm) Fill Time Exhaust. Port. Control Valves & Valve Accessories PNEUMADYNE, INC. Catalog 00 Phone 76-559-077 Fax 76-559-0547 Features Single stem design Compact size Four input options Numerous porting configurations Fully ported

More information

Accumulator charging valves & kits

Accumulator charging valves & kits accumulator charging valves & kits HYDROTECHNIK UK LIMITED Accumulator charging valves & kits Minimess gas charging valves Nitrogen pressure regulators & charging devices Nitrogen accumulator gas charging

More information

LEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES

LEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES LEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON KEEP FOR FUTURE REFERENCE

More information

Snap-tite E / EA-Series

Snap-tite E / EA-Series Snap-tite E / EA-Series eneral Purpose and Vacuum Couplings eaturing... Snap-tite quality with superior pressure and flow characteristics over the competition. Snap-tite's EA Series quick disconnect coupling

More information

Check Valves. E Check Valves E-1. Quick Coupling Division 8145 Lewis Road Minneapolis, MN

Check Valves. E Check Valves E-1. Quick Coupling Division 8145 Lewis Road Minneapolis, MN Check Valves E-1 Check Valves Introduction Multiple Hydraulic System pplications Parker Check Valves are unidirectional flow control devices used primarily in hydraulic systems to eliminate potential damage

More information

Edelbrock EFI Universal Fuel Sump System - Adjustable Part #36031, INSTALLATION INSTRUCTIONS

Edelbrock EFI Universal Fuel Sump System - Adjustable Part #36031, INSTALLATION INSTRUCTIONS Edelbrock EFI Universal Fuel Sump System - Adjustable Part #36031, 36032 INSTALLATION INSTRUCTIONS PLEASE study these instructions carefully before beginning this installation. This installation can be

More information

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD USA web:

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD USA   web: Push-In Fittings LF 3000 LF 3200: 3 mm LIQUIfit LF 300 LF 300/ LF 3900 LF 0 PARKER LEGRIS Industrial Connector Systems Products are available from: MARYLAND METRICS P.O. Box 21 Owings Mills, MD 21117 USA

More information

SKID MARK GARAGE. Axillary Fuel Supply

SKID MARK GARAGE. Axillary Fuel Supply 1 SKID MARK GARAGE Axillary Fuel Supply *Disclaimer: Our Axillary Fuel kits are designed to fit most late model GM vehicles with minimum modifications. While not quite a universal kit for all, it has been

More information

Swivel Joints Flexmaster Joints BD BD BD BD BD BD

Swivel Joints Flexmaster Joints BD BD BD BD BD BD FLUID CONVEYING PRODUCTS Section Pages Hose 15-67 Fittings 68-180 Adapters and Tube Fittings 181-228 Description Page How to Order 230 Selection Criteria 231 Selection Chart 232 Fluid Compatibility Chart

More information

Check valves Direct and pilot operated check valve functions for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Check valves Direct and pilot operated check valve functions for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) Hydraulic Screw-in Cartridge Valves (SiCV) Check valves Direct and pilot operated check valve functions for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Check valves CHECK VALVES... -4 FPR -

More information

WDV-2 2-way normally closed poppet with air pilot. When valve closes a spring biased internal piston draws back a small volume on outlet side (approx.

WDV-2 2-way normally closed poppet with air pilot. When valve closes a spring biased internal piston draws back a small volume on outlet side (approx. PV-1 MPS-2P SPECIALTY COMPONENTS Miniature pulse valve, a normally open 3-way valve that closes shortly after being pressurized and remains closed until supply pressure is exhausted and repressurized.

More information