fuse holders CYLINDRICAL1

Size: px
Start display at page:

Download "fuse holders CYLINDRICAL1"

Transcription

1 fuse holders CYLINDRICAL1

2 2

3 6 PMF MODULAR 7 MODULAR 9 PMC COMPACT 9 PMCC COMPACT 1 SC SCREW FIXING 1 BAC OPEN 11 PMP PANEL MOUNTING 11 PMB SOCKET

4 PMF MODULAR Modular fuse holders for industrial cylindrical fuse links. For mounting on DIN/EN rail. Single phase models, singlephase+neutral in only one module and multi-pole types. Available with fusing indicator or with microswitch for use with fuse links with striker (only fusing detection or fusing+pre-breaking+fuse link detection). Multi-pole units can be made of connection accessories. PMF fuse holders are made of self-extinguishable materials and have silver plated copper contacts. UL and CSA approvals. POLES MODULES REFERENCE In U PACKING 17,5 mm WITHOUT INDICATOR WITH INDICATOR (A) (V) Uni./BOX 8x32 I I /192 N N /192 I + N I /192 I + N I / I / I / N I / N I / I /48 1x38 I I /192 N N /192 I + N I /192 I + N I / I / I / N I / N I / I / I PMF MODULAR 24VDC WITH INDICATOR 1x38 I I II I III I PMF MODULAR ACCESSORIES 8x32 1x38 REFERENCE DESCRIPTION PACKING I 485 PINS FOR MULTIPOLE ASSEMBLY HANDLE TIES FOR MULTIPOLE ASSEMBLY IEC IEC EN EN IEC EN CSA C UL APPROVALS D I R E C T I V E 22/95/EC DATA 16 PMF MULTI-POLE ASSEMBLY gg CYLINDRICAL FUSES 2 am CYLINDRICAL FUSES 3 ar - gr HIGH SPEED FUSES FOR SEMICONDUCTORS SEE RAPIDPLUS

5 MODULAR z Available in a extended range of different versions with fuse indicator, with microswitch, 69V, 24 V DC, Microswitch FUSING+PRE-BREAKING+FUSE LINK DETECTION. x Accessory available to lock the fuse holder by a padlock. c IP2 Security accessory in terminal zones. For wires of section 1 mm 2. v All the versions with label holder for a good circuit identification. b Compact design. n Accessories for multiple poles assembly for fuse holders and microswitch. m Ventilation zones optimized for a better heat dissipation. 2 position DIN Rail fixation.. Made of a polymer high performance with a fusion temperature more than 3 C. This provides a safety margin against a possible overheating of the fuse, and when it exceeds the rated power acceptance of the fuse holder. / The fuse holder can be fixed/unfixed on DIN rail with the same screwing tools that the installer uses for cable terminal fixing, regardless the screw driver head is in form of slot or PZ2. Z Fuse holder is made of halogen free plastic, prepared for future restrictions on these substances. 14x51 POLES MODULES REFERENCE In U PACKING WITHOUT INDICATOR WITH INDICATOR (A) (V) Uni./BOX I 1, /9 N 1, /9 I + N / /45 3 4, /3 3 + N / /18 14x51 24VDC 1 1, /9 1+N / / MODULAR WITH MICROSWITCH 14x51 MODULAR ACCESSORIES 14x51 IEC IEC EN EN IEC EN DATA 16 POLES MODULES REFERENCE In U PACKING PREBREAKING FUSING - PRESENCE ONLY FUSION (A) (V) Uni./BOX I 1, /9 I + N / /45 3 4, /3 3+N / /18 REFERENCE DESCRIPTION PACKING 485 PIN FOR MULTIPOLE ASSEMBLY HANDLE TIES FOR MULTIPOLE ASSEMBLY HANDLE TIES FOR MICROSWITCH ASSEMBLY LOCK SUPPORT MICROSWITCH 1P * MICROSWITCH 3P * MICROSWITCH 3P (2M) * MICROSWITCH UNIPOLAR EXTENSION MICROSWITCH TRIPOLAR EXTENSION REPLACEMENT FUSING INDICATOR NEON 12/69 VAC REPLACEMENT FUSING INDICATOR LED 24 VDC SPECIAL PROTECTION IP2 ACCESSORIE * To convert standard base on microswitch base only FUSING and as microswitch spare PREBREAKING- FUSING-PRESENCE CSA C UL APPROVALS D I R E C T I V E 22/95/EC MULTI-POLE ASSEMBLY ASSEMBLY MICROSWITCH IDENTIFICATION BY LABEL LOCKING SYSTEM 2 gg CYLINDRICAL FUSES 2 am CYLINDRICAL FUSES ar - gr HIGH SPEED FUSES FOR SEMICONDUCTORS SEE RAPIDPLUS 5

6 MODULAR 22x58 POLES MODULES REFERENCE In U PACKING WITHOUT INDICATOR WITH INDICATOR (A) (V) Uni./BOX I /48 N /48 I + N / / / N / /8 22x58 24VDC /48 1+N / / MODULAR WITH MICROSWITCH 22x58 POLES MODULES REFERENCE In U PACKING PREBREAKING FUSING - PRESENCE ONLY FUSION (A) (V) Uni./BOX I /48 I + N / / /16 3+N / / MODULAR ACCESSORIES 22x58 REFERENCE DESCRIPTION PACKING 485 PIN FOR MULTIPOLE ASSEMBLY HANDLE TIES FOR MULTIPOLE ASSEMBLY HANDLE TIES FOR MICROSWITCH ASSEMBLY LOCK SUPPORT MICROSWITCH 1P * MICROSWITCH 3P * MICROSWITCH 3P (2M) * MICROSWITCH UNIPOLAR EXTENSION MICROSWITCH TRIPOLAR EXTENSION REPLACEMENT FUSING INDICATOR NEON 12/69 VAC REPLACEMENT FUSING INDICATOR LED 24 VDC SPECIAL PROTECTION IP2 ACCESSORIE SPECIAL CONNECTION M8 ACCESSORIE * To convert standard base on microswitch base only FUSING and as microswitch spare PREBREAKING- FUSING-PRESENCE 6 IEC IEC EN EN IEC EN CSA C UL APPROVALS D I R E C T I V E 22/95/EC DATA 16 MULTI-POLE ASSEMBLY ASSEMBLY MICROSWITCH IDENTIFICATION BY LABEL LOCKING SYSTEM 2 gg CYLINDRICAL FUSES 2 am CYLINDRICAL FUSES 3 ar - gr HIGH SPEED FUSES FOR SEMICONDUCTORS SEE RAPIDPLUS

7 PMC COMPACT Compact fuse holders for industrial cylindrical fuse links. Very low dimensions. For mounting on DIN/EN rail. Single phase models or single phase + neutral in only one module. Multi-pole units can be made with connection accessories. PMC fuse holders are made with self-extinguishable materials and have silver plated copper contacts. POLES MODULES REFERENCE In U PACKING 17,5 mm (A) (V) Uni./BOX 8x32 1x38 I /336 N /336 I + N /336 I + N / / / N / N / /84 I /336 N /336 I + N /336 I + N / / / N / N / / PMC COMPACT ACCESSORIES 8x32 1x38 SIZE REFERENCE DESCRIPTION PACKING 8x32 / 1x PINS FOR MULTIPOLE ASSEMBLY 12/3 8x32 / 1x HANDLE TIES FOR MULTIPOLE ASSEMBLY 12/ PMCC MODULAR Modular fuse holders for cylindrical CC class fuse links. For mounting on DIN/EN rail. Single phase and multi-pole types. Available with fusing indicator Multi-pole units can be made with connection accessories. PMCC fuse holders are made with self-extinguishable materials and have silver plated copper contacts. UL and CSA approvals. POLES REFERENCE In U PACKING WITHOUT INDICATOR WITH INDICATOR (A) (V) Uni./BOX I I /192 II I 3 6 6/96 III I 3 6 4/ IEC IEC EN EN IEC EN CSA C UL APPROVALS D I R E C T I V E 22/95/EC DATA 16 PMC & PMCC FUSE HOLDERS MULTI-POLE ASEMBLY gg CYLINDRICAL FUSES 2 am CYLINDRICAL FUSES 3 ar - gr HIGH SPEED FUSES FOR SEMICONDUCTORS SEE RAPIDPLUS 7

8 SC SCREW FIXING Fuse holders for industrial cylindrical fuse links. Screw fixing.available single-pole and neutrals. SC fuse holders are made with self-extinguishable materials and have silver plated copper contacts. POLES MODULES REFERENCE In U PACKING 17,5 mm (A) (V) Uni./BOX 8x32 I N N x38 I N N x51 I N N x58 I N N BAC OPEN Open bases for cylindrical fuses. The bases BAC for cylindrical fuses are particularly suitable for semiconductor fuses with high power dissipation and therefore needed to be mounted on open bases to facilitate the heat dissipation. Fixation on panel by screw. Made of thermosetting self extinguishing material. REFERENCE In U PACKING (A) (V) Uni./BOX 1x /3 14x /24 22x / IEC IEC EN EN IEC EN CSA C UL APPROVALS D I R E C T I V E 22/95/EC DATA gg CYLINDRICAL FUSES 2 am CYLINDRICAL FUSES 3 ar - gr HIGH SPEED FUSES FOR SEMICONDUCTORS SEE RAPIDPLUS

9 PMP PANEL MOUNTING REFERENCE DESCRIPTION In U PACKING (A) (V) Uni./BOX 1x BAYONET FIXING 3 6 1/ SCREW FIXING 3 6 1/ PMB PLUG CONNECTION REFERENCE In U PACKING (A) (V) Uni./BOX 1x /1 PMF PMC PMCC SC CONNECTION ACCESSORIES PHASE BUSBARS POLES MODULES REFERENCE SECTION PACKING (mm 2 ) 4856 I I II PMF PMC PMCC SC CONNECTION ACCESSORIES ACCESSORIES FOR PHASE BUSBARS REFERENCE DESCRIPTION PACKING INSULATED TERMINAL 6 25 mm2 (FEEDING ACROSS) INSULATED TERMINAL 6 5 mm2 (FEEDING ACROSS) END COVER FOR 1 PHASE BUSBAR IEC IEC EN EN IEC EN CSA C UL APPROVALS D I R E C T I V E 22/95/EC DATA 16 PMP 22 PHASE BUSBARS & ACCESSORIES 23 gg CYLINDRICAL FUSES 2 am CYLINDRICAL FUSES 3 ar - gr HIGH SPEED FUSES FOR SEMICONDUCTORS SEE RAPIDPLUS 9

10 CYLINDRICAL MODULAR PMF 8x32 PMF 1x38 PMCC PMC 8x32 PMC 1x38 14x51 22x58 BAC 1x38 BAC 14x51 BAC PMP 22x58 1x38 RATED CURRENT 25 A 32 A 3 A 25 A 32 A 5 A 125 A 32 A 5 A 1 A 3 A RATED VOLTAGE 4 V 69 V 6 V 4 V 69 V 69 V 69 V 69 V 69 V 69 V 6 V RATED POWER DISSIPATION 3 W 3 W 3 W 3 W 3 W 5 W 9,5 W 8 W 12 W 2 W UTILIZATION CATEGORY AC-22B 4V AC-22B 5V AC-21B 69 V AC-2 AC-2 AC-22B 5V AC-21B 69 V AC-21B 69 V PROTECTION DEGREE IP-2 IP-2 IP-2 IP-2 IP-2 IP-2 IP-2 IP- IP- IP- OPERATING TEMPERATURE C C C C C C C C C C C STORAGE TEMPERATURE C C C C C C C C C C C 2 C DERATING TEMPERATURE 3 C,95,95,95,95,95,95,95,95 4 C,9,9,9,9,9,9,9,9 5 C,8,8,8,8,8,8,8, DERATING Nº OF POLES 5 6,8,8,8,8,8,8,8 7 9,7,7,7,7,7,7,7 1,6,6,6,6,6,6,6 FIXING CONNECTING WIRE WITH LIGHTNING INDICATOR 12 4V AC MAX. TIGHTENING TORQUE RAIL DIN / EN SCREW,75 16 mm 2 STRANDED,75 25 mm 2 SOLID,75 6 mm 2 STRANDED (1P+N 1M),75 1 mm 2 SOLID (1P+N 1M) 2,5 Nm 2 Nm (1P+N 1M) 12 69V AC 12 24V DC 2,5 Nm 2 Nm (1P+N 1M),75 16 mm 2 STRANDED,75 25 mm 2 SOLID 12 69V AC 12 24V DC,75 6 mm 2 STRANDED,75 1 mm 2 SOLID,75 6 mm 2 STRANDED,75 1 mm 2 SOLID 1,5 25 mm 2 STRANDED 1,5 35 mm 2 SOLID 23 69V AC 24 6 VDC 1,5 35 mm 2 STRANDED 1,5 5 mm 2 SOLID 23 69V AC 24 6 VDC Ø 4 mm TERMINAL 2,5 35 mm 2 STRANDED 4 35 mm 2 SOLID 4 7 mm 2 STRANDED 6 95 mm 2 SOLID 2,5 Nm 2 Nm 2 Nm 3 Nm 4 Nm 2,5 Nm 2,5 Nm 3,5 Nm WITH MICROSWITCH 5A-25V FUSING PREBREAKING PRESENCE FUSING MULTIPOLAR UNION WITH ACCESSORIES LABEL HOLDER LOCKING ACCESSORIES 1

11 PMF PMCC MODULAR MULTI-POLE ASSEMBLY HANDLE TIE ASSEMBLY PIN PMC COMPACT MULTI-POLE ASSEMBLY ASSEMBLY PIN For multipole assemblies of fuse holders are necessary several accessories. EXAMPLE 1 A bipolar fuse holder c assembly pins z handle tie EXAMPLE 2 A bipolar PMF or PMC fuse holder x assembly pins z handle tie EXAMPLE 3 A three-pole PMF or PMC fuse holder v assembly pins x handle ties 11

12 PMF PMCC MODULAR PMC COMPACT +,5 +1, +1,5 +2, 12

13 14x51 MODULAR +,75 +1,5 +2,25 +3, 22x58 MODULAR +1, +2, +3, +4, 13

14 MODULAR MICROSWITCH MOUNTING Put on the microswitch on the guides, and push in horizontal movement to the final position. * For ONLY FUSION accessory, first mount the lifter in his place. MODULAR IDENTIFICATION BY LABEL Open the label-holder part when the fuse holder is totally closed or totally open, put on the label and close. MODULAR LOCKING MEANS A PADLOCK To avoid the operation and connection when the fuse holder is open, put on the accessory Padlock support sliding it for the guides, and covering the fuse link zone. (Is possible the use with or without fuse link) Introduce the fuse link trough the simmetriocal holes and close it. 14

15 SC SCREW FIXING SIZE A B C D E F G H 8,5x x x x BAC OPEN SIZE A B C ØF 1x x x

16 PMP BAYONET PANEL MOUNTING PMP SCREW PANEL MOUNTING 16

17 PMF PMC PMCC SC PHASE BUSBARS SEE DETAIL TYPE 1 TYPE 2 REFERENCE MODULES A B C TYPE END COVER ,6 17,8 229, ,8 17, ,8 17, TYPE 1 TYPE 2 PMF PMC PMCC SC ACCESSORIES FOR PHASE BUSBARS

18 HEAD OFFICE & FACTORY SILICI, CORNELLA DE LLOBREGAT BARCELONA SPAIN Tel Fax EXPORT SALES Tel Fax export@df-sa.es NATIONAL SALES Tel Fax comercial@df-sa.es 18

CYLINDRICAL. fuse holders

CYLINDRICAL. fuse holders fuse holders CYLINDRICAL 04 07 PMC MODULAR FUSE COMPACT HOLDERS 07 -CC FOR CC CLASS FUSE-LINKS 08 PMF 09 SC SCREW FIXING 10 PMB PLUG CONNECTION 10 CLIP CONTACT FOR φ10 FUSE-LINKS 09 BAC OPEN FUSE BASES

More information

fuse holders & bases

fuse holders & bases PMF Modular fuse holders for industrial cylindrical fuse links. For mounting on DIN/EN rail. Single phase models, single-phase+neutral in only one module and multi-pole types. Available with fusing indicator

More information

fuses fuse holders CYLINDRICAL

fuses fuse holders CYLINDRICAL fuses fuse holders 02 gg FUSES 04 am FUSES FUSES 09 PMC COMPACT 09 -CC FOR CC CLASS FUSE-LINKS 11 PMB PLUG CONNECTION 11 CLIP CONTACT FOR φ10 FUSE-LINKS 10 PMF 11 BAC OPEN FUSE BASES 06 gg FUSES FUSES

More information

CYLINDRICAL FUSES CYLINDRICAL FUSES

CYLINDRICAL FUSES CYLINDRICAL FUSES fuses 1 2 02 04 Cylindrical fuse links class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube with high

More information

CYLINDRICAL FUSES. 8x32. 10x38. 14x51. In REFERENCE U BREAKING CAPACITY REFERENCE U BREAKING CAPACITY PACKING (A) IEC /95/EC

CYLINDRICAL FUSES. 8x32. 10x38. 14x51. In REFERENCE U BREAKING CAPACITY REFERENCE U BREAKING CAPACITY PACKING (A) IEC /95/EC fuses 02 gg 04 am gg Cylindrical fuse links gg class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube

More information

FUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS

FUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS 1 2 06 PML 10/14x85 1500V FUSE HOLDERS 08 CLIP CONTACT FOR φ10 FUSE LINKS 05 PMX & 14x51 FUSE HOLDERS 02 gpv & 14x51 600 &/1100 FUSE LINKS 03 gpv 1200 & 1500V FUSE LINKS 04 gpv NH1, NH2 & NH3 FUSE LINKS

More information

FUSE BASES NH FUSE BASES 690V 160A 160A

FUSE BASES NH FUSE BASES 690V 160A 160A fuse bases NH NH 14 690V NH 16 ACCESSORIES FOR NH 18 CR 690V NH 20 SECTIONABLE NEUTRAL NH BASES 21 BS FUSE SWITCH DISCONNECTORS 690V NH NH Fuse bases for NH fuse links. For mounting on DIN/EN rail or

More information

fuse-links & fuse holders PHOTOVOLTAIC

fuse-links & fuse holders PHOTOVOLTAIC fuse-links & fuse holders 04 gpv FOR APPLICATIONS 04 gpv FOR APPLICATIONS 05 gpv & FOR APPLICATIONS 06 PMF FUSE HOLDERS FOR APPLICATIONS 07 ST & FUSE BASES FOR APPLICATIONS FUSE HOLDERS & BASES gpv 10x38

More information

RAPIDPLUS. high speed fuse links for semiconductors

RAPIDPLUS. high speed fuse links for semiconductors high speed fuse links for semiconductors RAPIDPLUS 2 PAGE04 ar PAGE05 gr PAGE06 gs NH ar RAPIDPLUS ar fuse links are intended to clearing short-circuits and have been designed and manufactured to have

More information

RAPIDPLUS. high speed fuse links for semiconductors

RAPIDPLUS. high speed fuse links for semiconductors high speed fuse links for semiconductors RAPIDPLUS 2 PAGE04 ar HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS PAGE05 gr HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS PAGE06 gs NH HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS

More information

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price gg fuselinks 500V (IEC60269 - VDE0636 - DIN43620) with fuse blown indication NH Fuse links gg class with high

More information

INDUSTRIAL CYLINDRICAL FUSE LINKS

INDUSTRIAL CYLINDRICAL FUSE LINKS gg Cylindrical gg class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube with high withstand to internal

More information

UltraSafe US22 Modular fuse-holders

UltraSafe US22 Modular fuse-holders UltraSafe US22 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive UltraSafe range of Mersen fuse-holders. are finger-safe under IEC standards

More information

Modulostar US10 Modular fuse-holders

Modulostar US10 Modular fuse-holders Modulostar US10 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC standards

More information

Modulostar CMS10 Modular fuse-holders

Modulostar CMS10 Modular fuse-holders Modulostar CMS10 FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC CYLINDRICAL FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC

More information

Cylindrical fuse-link

Cylindrical fuse-link Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH

More information

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC. Page -2 Page -2 AC FUSE HOLDERS Version without indicator: 1P, 1P+N, 2P, 3P, 3P+N Version with indicator: 1P For fuses x38, 14x51 and 22x58mm IEC class gg or am. IEC rated current: 32A, 50A, 0A IEC rated

More information

Fuse holders and fuses

Fuse holders and fuses Modular size for 10x38, 14x51 and 22x58mm fuses Finger safe - IEC IP20 degree of protection against accidental contact with live parts and with sealable cover for operators safety Version with status indicator

More information

INNOZED D0 fuse-bases with touch protection

INNOZED D0 fuse-bases with touch protection INNOZED D0 fusebases with touch protection INNOZED D0 fusebases with touch protection FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC D0 & D FUSE BASES FEATURES & BENEFITS INNOZED is a fuse base for D0 fuselinks,

More information

TX³ RCCBs 2P up to 100 A

TX³ RCCBs 2P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

E 90 range of fuse disconnectors and fuseholders Uncompromising performance

E 90 range of fuse disconnectors and fuseholders Uncompromising performance E 90 range of fuse disconnectors and fuseholders Uncompromising performance Designing simplicity ABB competence serving the most demanding customers Suitability for disconnection and switching, effective

More information

Cylindrical fuse-link

Cylindrical fuse-link ylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity haracteristics Body material 00 V A, 500 V A, 90 V A H 8-5 A/00 V H 0,5- A/500 V, 0-3 A/00 V H -5

More information

IEC Low Voltage General Purpose Protection

IEC Low Voltage General Purpose Protection , 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6

More information

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong

More information

PowerLine OS Switch Fuses A, 690V

PowerLine OS Switch Fuses A, 690V Technical Brochure PowerLine OS Switch Fuses 20...160 A, 690V Brochure OS 10 GB 99-04 9902CD04 ABB Control New Switch Fuse Range 2 3 Total user safety Total user safety Fuse carriers fully IP20 protected

More information

Microswitches M series

Microswitches M series Microswitches M series Technical data Housing Made of glass-reinforced polymer, self-extinguishing, shock-proof thermoplastic resin. Protection degree: IP40 (with protection art. VF C0) IP0 (with protection

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

IEC CYLINDRICAL FUSE SYSTEM

IEC CYLINDRICAL FUSE SYSTEM IEC CYLINDRICAL FUSE SYSTEM European Domestic and Industrial Fuse Links The Bussmann range of European cylindrical fuse links are available in a broad selection of physical sizes and current ratings for

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

Fuse disconnectors for cylindrical fuse-links

Fuse disconnectors for cylindrical fuse-links Advantages of fuse disconnector PF + N in one module Double connection clamps New method of mounting on the DIN rail and simple replacement LED indicator version Extraction of entire fuse-link when changing

More information

MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN s

MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN s Basic Efficiency up to 1500 V 1-pole 3-pole SILAS MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN successfully

More information

NEW EFD fuse disconnector

NEW EFD fuse disconnector NEW EFD fuse disconnector More space for finger to open fuse carrier Advantages of cylindrical fuse disconnector EFD ompliance with IE 60947-1, IE 60947-3, UL 4248-1, UL 4248-4, UL 4248-8, UL 486E and

More information

NH HRC Fuses. IEC & British Standard Fuses NHG B

NH HRC Fuses. IEC & British Standard Fuses NHG B NH HRC Fuses NHG B Specifications Class: gg/ g L Description: DIN square bodied, dual indication industrial fuses. Construction: Steatite insulator, corrosionproof (aluminum) metal parts with full-contact,

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A fuser_548_a_1_cat fuser_532_a_1_cat fuser_539_a_1_cat FUSERBLOC from 25 to 32 A FUSERBLOC from 630 to 1250 A FUSERBLOC from 32 to 400 A Function FUSERBLOC are manually operated multipolar fuse combination

More information

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules.

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules. Fuseology Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression Optima Fuse Holders & Overcurrent Protection Modules Compact, full-featured modules that deliver Type 2 coordinated protection,

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty switches are designed with the most up-todate disconnect

More information

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL) 690VAC (IEC) / VAC (UL) Protistor size 14x51 ar 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Low l²t for improved semiconductor

More information

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?... Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS SUMMARY OF MODELS Type 10 14 22 OPT22/OPT20 OPVF10 Rated operating current I e / Rated current I n 32 A / - 63 A / - 125 A / - 63 A / - - / 30 A Rated operating voltage U e / Rated voltage U n AC 690 V

More information

PANEL PANEL MOUNTING COMPONENTS

PANEL PANEL MOUNTING COMPONENTS PANEL PANEL MOUNTING COMPONENTS For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated connection technology

More information

LINOCUR Size D02 63A 230VAC/440VAC

LINOCUR Size D02 63A 230VAC/440VAC IEC FUSE SWITCH DISCONNECTORS D0 FUSE COMBINATION UNITS The D0 Linocur is a combination of switch disconnector fuse and Neozed 63A fuse-link, equiped with significant safety characeristics and sophisticated

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually

More information

SCREW-TYPE DISTRIBUTION BLOCKS

SCREW-TYPE DISTRIBUTION BLOCKS SCREW-TYPE DISTRIBUTION BLOCKS PRODUCT INFORMATION CONTA-CONNECT Screw-distributor blocks SVB The SVB screw-type distributor block makes it possible to distribute potential and power in a compact space

More information

INNOZED D0 fuse-bases with touch protection

INNOZED D0 fuse-bases with touch protection D0 fusebases with touch protection D0 fusebases with touch protection FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC D0 & D FUSE BASES FEATURES & BENEFITS is a fuse base for D0 fuselinks, sizes D0 and D02.

More information

SENTRON SIVACON ALPHA

SENTRON SIVACON ALPHA SENTRON SIVACON ALPHA Low-Voltage Power Distribution and Electrical Installation Technology Catalog Extract LV 10 Edition 10/2018 siemens.com/lowvoltage Related catalogs Low-Voltage Power Distribution

More information

IEC Low Voltage Products Module 4

IEC Low Voltage Products Module 4 IEC Low Voltage Products Module 4 IEC Low Voltage Products NH DIN o All variations o Features benefits o Dual indication IEC Cylindrical Fuse System o Wide range of sizes and ratings o CCP NEW Product!

More information

footprint of traditional fusible switches

footprint of traditional fusible switches Disconnect switches Contents Section page Description Compact Circuit Protector (CCP) disconnect switches Class CC, UL supplemental and IEC 0x38mm (CCP) -3 Class CF CUBEFuse (CCP-CF) 4-5 Compact Circuit

More information

NH LOW VOLTAGE a FUSE SYSTEM

NH LOW VOLTAGE a FUSE SYSTEM NH LOW VOLTAGE a FUSE SYSTEM NH DIN Low Voltage Fuse System from Cooper Bussmann High Breaking Capacity 400Vac, 500Vac and 690Vac Insulated Tag variants available Dual Indication VDE 066 Part 1 DIN 4 60

More information

USCC & USM UltraSafe TM Fuseholders

USCC & USM UltraSafe TM Fuseholders USCC & USM UltraSafe TM Fuseholders UltraSafe modular fuseholders for midget and class CC fuses Mersen UltraSafe Modular Fuseholders introduce a new level of safety for Class CC (USCC) and Midget 1-1/2

More information

SCREW-TYPE DISTRIBUTION BLOCKS

SCREW-TYPE DISTRIBUTION BLOCKS CONTA-CONNECT SCREW-TYPE DISTRIBUTION BLOCKS Our ideas Your advantages CONTA-CONNECT Screw-distributor blocks SVB The SVB screw-type distributor block makes it possible to distribute potential and power

More information

Horizontal fuse disconnects

Horizontal fuse disconnects THE NAME FOR SAFETY Horizontal fuse disconnects Horizontal fuse disconnects Horizontal fuse Disconnects are used in building installations, switchgear and controlgear as well as in power utility networks.

More information

PANEL-MOUNTING COMPONENTS FUSE HOLDERS. Quality

PANEL-MOUNTING COMPONENTS FUSE HOLDERS. Quality PANEL-MOUNTING COMPONENTS FUSE HOLDERS Quality For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

up to 63 A (1 module per pole)

up to 63 A (1 module per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Direct current MCB DX 3 16kA, up to 63 A (1 module per pole) CONTENTS PAGE 1. Description - Use... 1 2. Range... 1 3. Overall dimensions...

More information

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided

More information

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong

More information

(1,5 modules per pole)

(1,5 modules per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 36kA, 80A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Fuse switch-disconnectors

Fuse switch-disconnectors Fuse switch-disconnector FH000 is intended for fuse-links with blade contacts size 000. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version

More information

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A Cat. N (s): 4 197 49 to 4 199 23 CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions...

More information

R.C.B.O. SP / 1 module

R.C.B.O. SP / 1 module 87045 LIMOGES Cedex - France Telephone : (+33) 5 55 06 87 87 Fax : (+33) 5 55 06 88 88 R.C.B.O. SP / 1 module 6064 04 6064 64 05 6064 10 6064 11 6064 12 CONTENTS PAGES 1. Description, use... 1 2. Range...

More information

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits Fuses for Semiconductor Protection - European Standard Class: ar Voltage ratings: 660V AC to 1000V AC Current ratings: 16 A to 400 A Standards: UL 248-13 IEC 60269-1 & 4 DIN VDE 0636-40 DIN 43653 Approvals:

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

BETA Low-Voltage Circuit Protection

BETA Low-Voltage Circuit Protection BETA Low-Voltage Circuit Protection /2 Introduction Miniature Circuit Breakers /4 5SP and 5SY miniature circuit breakers / 5SJ6...-.KS miniature circuit breakers with plug-in terminal /21 5SY6 0 miniature

More information

Bussmann series modular fuse holders brochure. Compact modular fuse holders Products for Industrial, PV, IEC and UL applications

Bussmann series modular fuse holders brochure. Compact modular fuse holders Products for Industrial, PV, IEC and UL applications Bussmann series modular fuse holders brochure Compact modular fuse holders Products for Industrial, PV, IEC and UL applications Eaton is the leading source of fusible circuit protection solutions in the

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

Safety rope switches with reset for emergency stop

Safety rope switches with reset for emergency stop Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available

More information

Solid State Relays, 3-phase

Solid State Relays, 3-phase PMA Prozeß- und Maschinen-Automation GmbH Solid State Relays, 3-phase Zero-Point switching, heatsink integrated Main Characteristics: Three-phase controlled Zero switching LED display Various connection

More information

Load Break Disconnect Switches FSLBS

Load Break Disconnect Switches FSLBS Load Break Disconnect Switches FSLBS UL 508 Non-Fused Load Break Switches The FSLBS Load Break Switch is a newly designed industrial-grade switch capable of making or breaking loads up to 600V. It is suitable

More information

Safety rope switch with reset for emergency stop

Safety rope switch with reset for emergency stop Safety rope switch with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+,, FP FD FL FC 22 33 34,, CONDUIT ENTRIES Threaded conduit entries (standard) With

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

Practical and completely safe

Practical and completely safe FUSE RRIERS >>> Practical and completely safe Isolating fuse carriers 058 06 058 28 Dimensions (p. 0) onform to standard IE 60269-2/2. and to NF 63-2. Isolators conform to IE 60947-3. Icc: - 20 k with

More information

TMC 91H is now TMC 60 C Series

TMC 91H is now TMC 60 C Series TMC 91H is now TMC 60 C Series The new Thermal Magnetic Circuit Breaker is once again available and better than ever! The new version is not only UL recognized with the same electrical performance as the

More information

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.

More information

Safety switches for hinges

Safety switches for hinges Safety switches for hinges Selection diagram ACTUATORS L L6 L9 L16 FR FM FX FZ FK CONTACT BLOCKS 6 7 9 14 18 snap action 1NO+1N, make before break, shifted, close 21 4 66 NC 2NO+ 1NO+ CONDUIT ENTRIES Threaded

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED

More information

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

Contents. Volume 5 Motor Control and Protection CA E December

Contents. Volume 5 Motor Control and Protection CA E December Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions

More information

FL series position switches

FL series position switches FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable

More information

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 1.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 1.RST8 comprises NH fuse switch disconnectors for 250A. Products are designed in triple

More information

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description UL 489 Series UL 489 Series Description The Series miniature circuit breaker offers a compact solution for protection requirements. The U AND UP devices are UL 489 tested limiting and DIN rail mounted.

More information

System Benefits Should you have any further questions, please contact our UL hotline at: +49 (0)9563/ Connection Technology EQUES Technology

System Benefits Should you have any further questions, please contact our UL hotline at: +49 (0)9563/ Connection Technology EQUES Technology System Benefits The small external dimensions of the 60mm busbar system allow for a wide range of busbars, so that it can be easily adapted to a wide range of currents. These features result in the particularly

More information

vertical fuse switch disconnectors

vertical fuse switch disconnectors SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -

More information

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

NH Plastic bases. NH Plastic bases IEC NH FUSE BASES FEATURES & BENEFITS APPLICATIONS STANDARDS TECHNICAL DATA OVERVIEW

NH Plastic bases. NH Plastic bases IEC NH FUSE BASES FEATURES & BENEFITS APPLICATIONS STANDARDS TECHNICAL DATA OVERVIEW FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC NH FUSE BASES FEATURES & BENEFITS Polyester insulating bases Silver-plated contacts High-pressure spring contacts Screw or rail mounting Multipolar bases available

More information

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. . 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s 0090 00/01/02/06/07/11/12/13/14 0/01/02/06/07/11/12/13/14/18/19/23/24/25/26/ /18/19/23/24/25/26/45/46 45/46 0090

More information

Section Contents. Disconnect Switches

Section Contents. Disconnect Switches Section Contents Page Compact Circuit Protector (CCP) fused disconnect switches....................326-329 Fused, dead front disconnect switches...........329 Fusible Disconnect Switch Overview............330

More information

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics Miniature circuit breakers General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for

More information

Microswitches MK series

Microswitches MK series D Microswitches MK series Introduction Microswitches of MK series have been developed in order to add new features to traditional and tested microswitches of Pizzato Elettrica (cross-reference at page

More information

INNOVATION IS OUR POWER.

INNOVATION IS OUR POWER. MANUAL 2019 EN INNOVATION IS OUR POWER. Wöhner develops system solutions for the electro-technical market. For over 90 years, the Wöhner name has been synonymous with impressive technical achievements

More information

Standard terminal blocks

Standard terminal blocks T01005 001229 Standard terminal blocks DIN 1 - Spacing 6 mm + 0,05 (.28") M 4/6... Standard blocks Blue Orange Yellow Green ed Black White Brown Beige V0 Blue V0 M 4/6 0115 116.07 M 4/6.N 0125 116.01 M

More information

Microswitches MK series

Microswitches MK series Microswitches MK series Microswitches of MK series have been developed in order to add new features to traditional and tested microswitches of Pizzato Elettrica. These products have been designed with

More information