fuse holders CYLINDRICAL1
|
|
- Quentin Moore
- 5 years ago
- Views:
Transcription
1 fuse holders CYLINDRICAL1
2 2
3 6 PMF MODULAR 7 MODULAR 9 PMC COMPACT 9 PMCC COMPACT 1 SC SCREW FIXING 1 BAC OPEN 11 PMP PANEL MOUNTING 11 PMB SOCKET
4 PMF MODULAR Modular fuse holders for industrial cylindrical fuse links. For mounting on DIN/EN rail. Single phase models, singlephase+neutral in only one module and multi-pole types. Available with fusing indicator or with microswitch for use with fuse links with striker (only fusing detection or fusing+pre-breaking+fuse link detection). Multi-pole units can be made of connection accessories. PMF fuse holders are made of self-extinguishable materials and have silver plated copper contacts. UL and CSA approvals. POLES MODULES REFERENCE In U PACKING 17,5 mm WITHOUT INDICATOR WITH INDICATOR (A) (V) Uni./BOX 8x32 I I /192 N N /192 I + N I /192 I + N I / I / I / N I / N I / I /48 1x38 I I /192 N N /192 I + N I /192 I + N I / I / I / N I / N I / I / I PMF MODULAR 24VDC WITH INDICATOR 1x38 I I II I III I PMF MODULAR ACCESSORIES 8x32 1x38 REFERENCE DESCRIPTION PACKING I 485 PINS FOR MULTIPOLE ASSEMBLY HANDLE TIES FOR MULTIPOLE ASSEMBLY IEC IEC EN EN IEC EN CSA C UL APPROVALS D I R E C T I V E 22/95/EC DATA 16 PMF MULTI-POLE ASSEMBLY gg CYLINDRICAL FUSES 2 am CYLINDRICAL FUSES 3 ar - gr HIGH SPEED FUSES FOR SEMICONDUCTORS SEE RAPIDPLUS
5 MODULAR z Available in a extended range of different versions with fuse indicator, with microswitch, 69V, 24 V DC, Microswitch FUSING+PRE-BREAKING+FUSE LINK DETECTION. x Accessory available to lock the fuse holder by a padlock. c IP2 Security accessory in terminal zones. For wires of section 1 mm 2. v All the versions with label holder for a good circuit identification. b Compact design. n Accessories for multiple poles assembly for fuse holders and microswitch. m Ventilation zones optimized for a better heat dissipation. 2 position DIN Rail fixation.. Made of a polymer high performance with a fusion temperature more than 3 C. This provides a safety margin against a possible overheating of the fuse, and when it exceeds the rated power acceptance of the fuse holder. / The fuse holder can be fixed/unfixed on DIN rail with the same screwing tools that the installer uses for cable terminal fixing, regardless the screw driver head is in form of slot or PZ2. Z Fuse holder is made of halogen free plastic, prepared for future restrictions on these substances. 14x51 POLES MODULES REFERENCE In U PACKING WITHOUT INDICATOR WITH INDICATOR (A) (V) Uni./BOX I 1, /9 N 1, /9 I + N / /45 3 4, /3 3 + N / /18 14x51 24VDC 1 1, /9 1+N / / MODULAR WITH MICROSWITCH 14x51 MODULAR ACCESSORIES 14x51 IEC IEC EN EN IEC EN DATA 16 POLES MODULES REFERENCE In U PACKING PREBREAKING FUSING - PRESENCE ONLY FUSION (A) (V) Uni./BOX I 1, /9 I + N / /45 3 4, /3 3+N / /18 REFERENCE DESCRIPTION PACKING 485 PIN FOR MULTIPOLE ASSEMBLY HANDLE TIES FOR MULTIPOLE ASSEMBLY HANDLE TIES FOR MICROSWITCH ASSEMBLY LOCK SUPPORT MICROSWITCH 1P * MICROSWITCH 3P * MICROSWITCH 3P (2M) * MICROSWITCH UNIPOLAR EXTENSION MICROSWITCH TRIPOLAR EXTENSION REPLACEMENT FUSING INDICATOR NEON 12/69 VAC REPLACEMENT FUSING INDICATOR LED 24 VDC SPECIAL PROTECTION IP2 ACCESSORIE * To convert standard base on microswitch base only FUSING and as microswitch spare PREBREAKING- FUSING-PRESENCE CSA C UL APPROVALS D I R E C T I V E 22/95/EC MULTI-POLE ASSEMBLY ASSEMBLY MICROSWITCH IDENTIFICATION BY LABEL LOCKING SYSTEM 2 gg CYLINDRICAL FUSES 2 am CYLINDRICAL FUSES ar - gr HIGH SPEED FUSES FOR SEMICONDUCTORS SEE RAPIDPLUS 5
6 MODULAR 22x58 POLES MODULES REFERENCE In U PACKING WITHOUT INDICATOR WITH INDICATOR (A) (V) Uni./BOX I /48 N /48 I + N / / / N / /8 22x58 24VDC /48 1+N / / MODULAR WITH MICROSWITCH 22x58 POLES MODULES REFERENCE In U PACKING PREBREAKING FUSING - PRESENCE ONLY FUSION (A) (V) Uni./BOX I /48 I + N / / /16 3+N / / MODULAR ACCESSORIES 22x58 REFERENCE DESCRIPTION PACKING 485 PIN FOR MULTIPOLE ASSEMBLY HANDLE TIES FOR MULTIPOLE ASSEMBLY HANDLE TIES FOR MICROSWITCH ASSEMBLY LOCK SUPPORT MICROSWITCH 1P * MICROSWITCH 3P * MICROSWITCH 3P (2M) * MICROSWITCH UNIPOLAR EXTENSION MICROSWITCH TRIPOLAR EXTENSION REPLACEMENT FUSING INDICATOR NEON 12/69 VAC REPLACEMENT FUSING INDICATOR LED 24 VDC SPECIAL PROTECTION IP2 ACCESSORIE SPECIAL CONNECTION M8 ACCESSORIE * To convert standard base on microswitch base only FUSING and as microswitch spare PREBREAKING- FUSING-PRESENCE 6 IEC IEC EN EN IEC EN CSA C UL APPROVALS D I R E C T I V E 22/95/EC DATA 16 MULTI-POLE ASSEMBLY ASSEMBLY MICROSWITCH IDENTIFICATION BY LABEL LOCKING SYSTEM 2 gg CYLINDRICAL FUSES 2 am CYLINDRICAL FUSES 3 ar - gr HIGH SPEED FUSES FOR SEMICONDUCTORS SEE RAPIDPLUS
7 PMC COMPACT Compact fuse holders for industrial cylindrical fuse links. Very low dimensions. For mounting on DIN/EN rail. Single phase models or single phase + neutral in only one module. Multi-pole units can be made with connection accessories. PMC fuse holders are made with self-extinguishable materials and have silver plated copper contacts. POLES MODULES REFERENCE In U PACKING 17,5 mm (A) (V) Uni./BOX 8x32 1x38 I /336 N /336 I + N /336 I + N / / / N / N / /84 I /336 N /336 I + N /336 I + N / / / N / N / / PMC COMPACT ACCESSORIES 8x32 1x38 SIZE REFERENCE DESCRIPTION PACKING 8x32 / 1x PINS FOR MULTIPOLE ASSEMBLY 12/3 8x32 / 1x HANDLE TIES FOR MULTIPOLE ASSEMBLY 12/ PMCC MODULAR Modular fuse holders for cylindrical CC class fuse links. For mounting on DIN/EN rail. Single phase and multi-pole types. Available with fusing indicator Multi-pole units can be made with connection accessories. PMCC fuse holders are made with self-extinguishable materials and have silver plated copper contacts. UL and CSA approvals. POLES REFERENCE In U PACKING WITHOUT INDICATOR WITH INDICATOR (A) (V) Uni./BOX I I /192 II I 3 6 6/96 III I 3 6 4/ IEC IEC EN EN IEC EN CSA C UL APPROVALS D I R E C T I V E 22/95/EC DATA 16 PMC & PMCC FUSE HOLDERS MULTI-POLE ASEMBLY gg CYLINDRICAL FUSES 2 am CYLINDRICAL FUSES 3 ar - gr HIGH SPEED FUSES FOR SEMICONDUCTORS SEE RAPIDPLUS 7
8 SC SCREW FIXING Fuse holders for industrial cylindrical fuse links. Screw fixing.available single-pole and neutrals. SC fuse holders are made with self-extinguishable materials and have silver plated copper contacts. POLES MODULES REFERENCE In U PACKING 17,5 mm (A) (V) Uni./BOX 8x32 I N N x38 I N N x51 I N N x58 I N N BAC OPEN Open bases for cylindrical fuses. The bases BAC for cylindrical fuses are particularly suitable for semiconductor fuses with high power dissipation and therefore needed to be mounted on open bases to facilitate the heat dissipation. Fixation on panel by screw. Made of thermosetting self extinguishing material. REFERENCE In U PACKING (A) (V) Uni./BOX 1x /3 14x /24 22x / IEC IEC EN EN IEC EN CSA C UL APPROVALS D I R E C T I V E 22/95/EC DATA gg CYLINDRICAL FUSES 2 am CYLINDRICAL FUSES 3 ar - gr HIGH SPEED FUSES FOR SEMICONDUCTORS SEE RAPIDPLUS
9 PMP PANEL MOUNTING REFERENCE DESCRIPTION In U PACKING (A) (V) Uni./BOX 1x BAYONET FIXING 3 6 1/ SCREW FIXING 3 6 1/ PMB PLUG CONNECTION REFERENCE In U PACKING (A) (V) Uni./BOX 1x /1 PMF PMC PMCC SC CONNECTION ACCESSORIES PHASE BUSBARS POLES MODULES REFERENCE SECTION PACKING (mm 2 ) 4856 I I II PMF PMC PMCC SC CONNECTION ACCESSORIES ACCESSORIES FOR PHASE BUSBARS REFERENCE DESCRIPTION PACKING INSULATED TERMINAL 6 25 mm2 (FEEDING ACROSS) INSULATED TERMINAL 6 5 mm2 (FEEDING ACROSS) END COVER FOR 1 PHASE BUSBAR IEC IEC EN EN IEC EN CSA C UL APPROVALS D I R E C T I V E 22/95/EC DATA 16 PMP 22 PHASE BUSBARS & ACCESSORIES 23 gg CYLINDRICAL FUSES 2 am CYLINDRICAL FUSES 3 ar - gr HIGH SPEED FUSES FOR SEMICONDUCTORS SEE RAPIDPLUS 9
10 CYLINDRICAL MODULAR PMF 8x32 PMF 1x38 PMCC PMC 8x32 PMC 1x38 14x51 22x58 BAC 1x38 BAC 14x51 BAC PMP 22x58 1x38 RATED CURRENT 25 A 32 A 3 A 25 A 32 A 5 A 125 A 32 A 5 A 1 A 3 A RATED VOLTAGE 4 V 69 V 6 V 4 V 69 V 69 V 69 V 69 V 69 V 69 V 6 V RATED POWER DISSIPATION 3 W 3 W 3 W 3 W 3 W 5 W 9,5 W 8 W 12 W 2 W UTILIZATION CATEGORY AC-22B 4V AC-22B 5V AC-21B 69 V AC-2 AC-2 AC-22B 5V AC-21B 69 V AC-21B 69 V PROTECTION DEGREE IP-2 IP-2 IP-2 IP-2 IP-2 IP-2 IP-2 IP- IP- IP- OPERATING TEMPERATURE C C C C C C C C C C C STORAGE TEMPERATURE C C C C C C C C C C C 2 C DERATING TEMPERATURE 3 C,95,95,95,95,95,95,95,95 4 C,9,9,9,9,9,9,9,9 5 C,8,8,8,8,8,8,8, DERATING Nº OF POLES 5 6,8,8,8,8,8,8,8 7 9,7,7,7,7,7,7,7 1,6,6,6,6,6,6,6 FIXING CONNECTING WIRE WITH LIGHTNING INDICATOR 12 4V AC MAX. TIGHTENING TORQUE RAIL DIN / EN SCREW,75 16 mm 2 STRANDED,75 25 mm 2 SOLID,75 6 mm 2 STRANDED (1P+N 1M),75 1 mm 2 SOLID (1P+N 1M) 2,5 Nm 2 Nm (1P+N 1M) 12 69V AC 12 24V DC 2,5 Nm 2 Nm (1P+N 1M),75 16 mm 2 STRANDED,75 25 mm 2 SOLID 12 69V AC 12 24V DC,75 6 mm 2 STRANDED,75 1 mm 2 SOLID,75 6 mm 2 STRANDED,75 1 mm 2 SOLID 1,5 25 mm 2 STRANDED 1,5 35 mm 2 SOLID 23 69V AC 24 6 VDC 1,5 35 mm 2 STRANDED 1,5 5 mm 2 SOLID 23 69V AC 24 6 VDC Ø 4 mm TERMINAL 2,5 35 mm 2 STRANDED 4 35 mm 2 SOLID 4 7 mm 2 STRANDED 6 95 mm 2 SOLID 2,5 Nm 2 Nm 2 Nm 3 Nm 4 Nm 2,5 Nm 2,5 Nm 3,5 Nm WITH MICROSWITCH 5A-25V FUSING PREBREAKING PRESENCE FUSING MULTIPOLAR UNION WITH ACCESSORIES LABEL HOLDER LOCKING ACCESSORIES 1
11 PMF PMCC MODULAR MULTI-POLE ASSEMBLY HANDLE TIE ASSEMBLY PIN PMC COMPACT MULTI-POLE ASSEMBLY ASSEMBLY PIN For multipole assemblies of fuse holders are necessary several accessories. EXAMPLE 1 A bipolar fuse holder c assembly pins z handle tie EXAMPLE 2 A bipolar PMF or PMC fuse holder x assembly pins z handle tie EXAMPLE 3 A three-pole PMF or PMC fuse holder v assembly pins x handle ties 11
12 PMF PMCC MODULAR PMC COMPACT +,5 +1, +1,5 +2, 12
13 14x51 MODULAR +,75 +1,5 +2,25 +3, 22x58 MODULAR +1, +2, +3, +4, 13
14 MODULAR MICROSWITCH MOUNTING Put on the microswitch on the guides, and push in horizontal movement to the final position. * For ONLY FUSION accessory, first mount the lifter in his place. MODULAR IDENTIFICATION BY LABEL Open the label-holder part when the fuse holder is totally closed or totally open, put on the label and close. MODULAR LOCKING MEANS A PADLOCK To avoid the operation and connection when the fuse holder is open, put on the accessory Padlock support sliding it for the guides, and covering the fuse link zone. (Is possible the use with or without fuse link) Introduce the fuse link trough the simmetriocal holes and close it. 14
15 SC SCREW FIXING SIZE A B C D E F G H 8,5x x x x BAC OPEN SIZE A B C ØF 1x x x
16 PMP BAYONET PANEL MOUNTING PMP SCREW PANEL MOUNTING 16
17 PMF PMC PMCC SC PHASE BUSBARS SEE DETAIL TYPE 1 TYPE 2 REFERENCE MODULES A B C TYPE END COVER ,6 17,8 229, ,8 17, ,8 17, TYPE 1 TYPE 2 PMF PMC PMCC SC ACCESSORIES FOR PHASE BUSBARS
18 HEAD OFFICE & FACTORY SILICI, CORNELLA DE LLOBREGAT BARCELONA SPAIN Tel Fax EXPORT SALES Tel Fax export@df-sa.es NATIONAL SALES Tel Fax comercial@df-sa.es 18
CYLINDRICAL. fuse holders
fuse holders CYLINDRICAL 04 07 PMC MODULAR FUSE COMPACT HOLDERS 07 -CC FOR CC CLASS FUSE-LINKS 08 PMF 09 SC SCREW FIXING 10 PMB PLUG CONNECTION 10 CLIP CONTACT FOR φ10 FUSE-LINKS 09 BAC OPEN FUSE BASES
More informationfuse holders & bases
PMF Modular fuse holders for industrial cylindrical fuse links. For mounting on DIN/EN rail. Single phase models, single-phase+neutral in only one module and multi-pole types. Available with fusing indicator
More informationfuses fuse holders CYLINDRICAL
fuses fuse holders 02 gg FUSES 04 am FUSES FUSES 09 PMC COMPACT 09 -CC FOR CC CLASS FUSE-LINKS 11 PMB PLUG CONNECTION 11 CLIP CONTACT FOR φ10 FUSE-LINKS 10 PMF 11 BAC OPEN FUSE BASES 06 gg FUSES FUSES
More informationCYLINDRICAL FUSES CYLINDRICAL FUSES
fuses 1 2 02 04 Cylindrical fuse links class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube with high
More informationCYLINDRICAL FUSES. 8x32. 10x38. 14x51. In REFERENCE U BREAKING CAPACITY REFERENCE U BREAKING CAPACITY PACKING (A) IEC /95/EC
fuses 02 gg 04 am gg Cylindrical fuse links gg class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube
More informationFUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS
1 2 06 PML 10/14x85 1500V FUSE HOLDERS 08 CLIP CONTACT FOR φ10 FUSE LINKS 05 PMX & 14x51 FUSE HOLDERS 02 gpv & 14x51 600 &/1100 FUSE LINKS 03 gpv 1200 & 1500V FUSE LINKS 04 gpv NH1, NH2 & NH3 FUSE LINKS
More informationFUSE BASES NH FUSE BASES 690V 160A 160A
fuse bases NH NH 14 690V NH 16 ACCESSORIES FOR NH 18 CR 690V NH 20 SECTIONABLE NEUTRAL NH BASES 21 BS FUSE SWITCH DISCONNECTORS 690V NH NH Fuse bases for NH fuse links. For mounting on DIN/EN rail or
More informationfuse-links & fuse holders PHOTOVOLTAIC
fuse-links & fuse holders 04 gpv FOR APPLICATIONS 04 gpv FOR APPLICATIONS 05 gpv & FOR APPLICATIONS 06 PMF FUSE HOLDERS FOR APPLICATIONS 07 ST & FUSE BASES FOR APPLICATIONS FUSE HOLDERS & BASES gpv 10x38
More informationRAPIDPLUS. high speed fuse links for semiconductors
high speed fuse links for semiconductors RAPIDPLUS 2 PAGE04 ar PAGE05 gr PAGE06 gs NH ar RAPIDPLUS ar fuse links are intended to clearing short-circuits and have been designed and manufactured to have
More informationRAPIDPLUS. high speed fuse links for semiconductors
high speed fuse links for semiconductors RAPIDPLUS 2 PAGE04 ar HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS PAGE05 gr HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS PAGE06 gs NH HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS
More informationnew NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price
NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price gg fuselinks 500V (IEC60269 - VDE0636 - DIN43620) with fuse blown indication NH Fuse links gg class with high
More informationINDUSTRIAL CYLINDRICAL FUSE LINKS
gg Cylindrical gg class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube with high withstand to internal
More informationUltraSafe US22 Modular fuse-holders
UltraSafe US22 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive UltraSafe range of Mersen fuse-holders. are finger-safe under IEC standards
More informationModulostar US10 Modular fuse-holders
Modulostar US10 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC standards
More informationModulostar CMS10 Modular fuse-holders
Modulostar CMS10 FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC CYLINDRICAL FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC
More informationCylindrical fuse-link
Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH
More informationPage 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.
Page -2 Page -2 AC FUSE HOLDERS Version without indicator: 1P, 1P+N, 2P, 3P, 3P+N Version with indicator: 1P For fuses x38, 14x51 and 22x58mm IEC class gg or am. IEC rated current: 32A, 50A, 0A IEC rated
More informationFuse holders and fuses
Modular size for 10x38, 14x51 and 22x58mm fuses Finger safe - IEC IP20 degree of protection against accidental contact with live parts and with sealable cover for operators safety Version with status indicator
More informationINNOZED D0 fuse-bases with touch protection
INNOZED D0 fusebases with touch protection INNOZED D0 fusebases with touch protection FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC D0 & D FUSE BASES FEATURES & BENEFITS INNOZED is a fuse base for D0 fuselinks,
More informationTX³ RCCBs 2P up to 100 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationDX³ RCCBs - ID 4P up to 100 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More information, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationE 90 range of fuse disconnectors and fuseholders Uncompromising performance
E 90 range of fuse disconnectors and fuseholders Uncompromising performance Designing simplicity ABB competence serving the most demanding customers Suitability for disconnection and switching, effective
More informationCylindrical fuse-link
ylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity haracteristics Body material 00 V A, 500 V A, 90 V A H 8-5 A/00 V H 0,5- A/500 V, 0-3 A/00 V H -5
More informationIEC Low Voltage General Purpose Protection
, 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6
More informationFUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A
Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong
More informationPowerLine OS Switch Fuses A, 690V
Technical Brochure PowerLine OS Switch Fuses 20...160 A, 690V Brochure OS 10 GB 99-04 9902CD04 ABB Control New Switch Fuse Range 2 3 Total user safety Total user safety Fuse carriers fully IP20 protected
More informationMicroswitches M series
Microswitches M series Technical data Housing Made of glass-reinforced polymer, self-extinguishing, shock-proof thermoplastic resin. Protection degree: IP40 (with protection art. VF C0) IP0 (with protection
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More informationNon-Fused Load Break Switches FSSC, SX, SXDC, SC
Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty
More informationIEC CYLINDRICAL FUSE SYSTEM
IEC CYLINDRICAL FUSE SYSTEM European Domestic and Industrial Fuse Links The Bussmann range of European cylindrical fuse links are available in a broad selection of physical sizes and current ratings for
More informationRX 3 MCB 4500 A Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationNon-fusable disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages
More informationFUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are
More informationDNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation
More informationFuse disconnectors for cylindrical fuse-links
Advantages of fuse disconnector PF + N in one module Double connection clamps New method of mounting on the DIN rail and simple replacement LED indicator version Extraction of entire fuse-link when changing
More informationMM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN s
Basic Efficiency up to 1500 V 1-pole 3-pole SILAS MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN successfully
More informationNEW EFD fuse disconnector
NEW EFD fuse disconnector More space for finger to open fuse carrier Advantages of cylindrical fuse disconnector EFD ompliance with IE 60947-1, IE 60947-3, UL 4248-1, UL 4248-4, UL 4248-8, UL 486E and
More informationNH HRC Fuses. IEC & British Standard Fuses NHG B
NH HRC Fuses NHG B Specifications Class: gg/ g L Description: DIN square bodied, dual indication industrial fuses. Construction: Steatite insulator, corrosionproof (aluminum) metal parts with full-contact,
More informationFUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
fuser_548_a_1_cat fuser_532_a_1_cat fuser_539_a_1_cat FUSERBLOC from 25 to 32 A FUSERBLOC from 630 to 1250 A FUSERBLOC from 32 to 400 A Function FUSERBLOC are manually operated multipolar fuse combination
More informationFuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules.
Fuseology Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression Optima Fuse Holders & Overcurrent Protection Modules Compact, full-featured modules that deliver Type 2 coordinated protection,
More informationNon-Fused Load Break Switches FSSC, SX, SXDC, SC
UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty switches are designed with the most up-todate disconnect
More informationProtistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)
690VAC (IEC) / VAC (UL) Protistor size 14x51 ar 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Low l²t for improved semiconductor
More informationLoad break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...
Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch
More informationVarius SUMMARY OF MODELS
SUMMARY OF MODELS Type 10 14 22 OPT22/OPT20 OPVF10 Rated operating current I e / Rated current I n 32 A / - 63 A / - 125 A / - 63 A / - - / 30 A Rated operating voltage U e / Rated voltage U n AC 690 V
More informationPANEL PANEL MOUNTING COMPONENTS
PANEL PANEL MOUNTING COMPONENTS For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated connection technology
More informationLINOCUR Size D02 63A 230VAC/440VAC
IEC FUSE SWITCH DISCONNECTORS D0 FUSE COMBINATION UNITS The D0 Linocur is a combination of switch disconnector fuse and Neozed 63A fuse-link, equiped with significant safety characeristics and sophisticated
More informationFUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually
More informationSCREW-TYPE DISTRIBUTION BLOCKS
SCREW-TYPE DISTRIBUTION BLOCKS PRODUCT INFORMATION CONTA-CONNECT Screw-distributor blocks SVB The SVB screw-type distributor block makes it possible to distribute potential and power in a compact space
More informationINNOZED D0 fuse-bases with touch protection
D0 fusebases with touch protection D0 fusebases with touch protection FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC D0 & D FUSE BASES FEATURES & BENEFITS is a fuse base for D0 fuselinks, sizes D0 and D02.
More informationSENTRON SIVACON ALPHA
SENTRON SIVACON ALPHA Low-Voltage Power Distribution and Electrical Installation Technology Catalog Extract LV 10 Edition 10/2018 siemens.com/lowvoltage Related catalogs Low-Voltage Power Distribution
More informationIEC Low Voltage Products Module 4
IEC Low Voltage Products Module 4 IEC Low Voltage Products NH DIN o All variations o Features benefits o Dual indication IEC Cylindrical Fuse System o Wide range of sizes and ratings o CCP NEW Product!
More informationfootprint of traditional fusible switches
Disconnect switches Contents Section page Description Compact Circuit Protector (CCP) disconnect switches Class CC, UL supplemental and IEC 0x38mm (CCP) -3 Class CF CUBEFuse (CCP-CF) 4-5 Compact Circuit
More informationNH LOW VOLTAGE a FUSE SYSTEM
NH LOW VOLTAGE a FUSE SYSTEM NH DIN Low Voltage Fuse System from Cooper Bussmann High Breaking Capacity 400Vac, 500Vac and 690Vac Insulated Tag variants available Dual Indication VDE 066 Part 1 DIN 4 60
More informationUSCC & USM UltraSafe TM Fuseholders
USCC & USM UltraSafe TM Fuseholders UltraSafe modular fuseholders for midget and class CC fuses Mersen UltraSafe Modular Fuseholders introduce a new level of safety for Class CC (USCC) and Midget 1-1/2
More informationSCREW-TYPE DISTRIBUTION BLOCKS
CONTA-CONNECT SCREW-TYPE DISTRIBUTION BLOCKS Our ideas Your advantages CONTA-CONNECT Screw-distributor blocks SVB The SVB screw-type distributor block makes it possible to distribute potential and power
More informationHorizontal fuse disconnects
THE NAME FOR SAFETY Horizontal fuse disconnects Horizontal fuse disconnects Horizontal fuse Disconnects are used in building installations, switchgear and controlgear as well as in power utility networks.
More informationPANEL-MOUNTING COMPONENTS FUSE HOLDERS. Quality
PANEL-MOUNTING COMPONENTS FUSE HOLDERS Quality For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated
More informationBETA Switching Switches and Light Indicators
Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET
More informationup to 63 A (1 module per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Direct current MCB DX 3 16kA, up to 63 A (1 module per pole) CONTENTS PAGE 1. Description - Use... 1 2. Range... 1 3. Overall dimensions...
More informationBasic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors
MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided
More informationDX³ RCBO 4500/6 ka Phase + Neutral, neutral on left
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationSIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong
More information(1,5 modules per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 36kA, 80A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationFuse switch-disconnectors
Fuse switch-disconnector FH000 is intended for fuse-links with blade contacts size 000. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version
More informationRX 3 M.C.B A up to 63 A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A Cat. N (s): 4 197 49 to 4 199 23 CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions...
More informationR.C.B.O. SP / 1 module
87045 LIMOGES Cedex - France Telephone : (+33) 5 55 06 87 87 Fax : (+33) 5 55 06 88 88 R.C.B.O. SP / 1 module 6064 04 6064 64 05 6064 10 6064 11 6064 12 CONTENTS PAGES 1. Description, use... 1 2. Range...
More informationFuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits
Fuses for Semiconductor Protection - European Standard Class: ar Voltage ratings: 660V AC to 1000V AC Current ratings: 16 A to 400 A Standards: UL 248-13 IEC 60269-1 & 4 DIN VDE 0636-40 DIN 43653 Approvals:
More informationDX³ 4-pole RCBO 6000 A/10 ka
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationBETA Low-Voltage Circuit Protection
BETA Low-Voltage Circuit Protection /2 Introduction Miniature Circuit Breakers /4 5SP and 5SY miniature circuit breakers / 5SJ6...-.KS miniature circuit breakers with plug-in terminal /21 5SY6 0 miniature
More informationBussmann series modular fuse holders brochure. Compact modular fuse holders Products for Industrial, PV, IEC and UL applications
Bussmann series modular fuse holders brochure Compact modular fuse holders Products for Industrial, PV, IEC and UL applications Eaton is the leading source of fusible circuit protection solutions in the
More informationFUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A
Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved
More informationSafety rope switches with reset for emergency stop
Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available
More informationSolid State Relays, 3-phase
PMA Prozeß- und Maschinen-Automation GmbH Solid State Relays, 3-phase Zero-Point switching, heatsink integrated Main Characteristics: Three-phase controlled Zero switching LED display Various connection
More informationLoad Break Disconnect Switches FSLBS
Load Break Disconnect Switches FSLBS UL 508 Non-Fused Load Break Switches The FSLBS Load Break Switch is a newly designed industrial-grade switch capable of making or breaking loads up to 600V. It is suitable
More informationSafety rope switch with reset for emergency stop
Safety rope switch with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+,, FP FD FL FC 22 33 34,, CONDUIT ENTRIES Threaded conduit entries (standard) With
More informationNon-Fused Load Break Switches FSSC, SX, SXDC, SC
Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty
More informationPractical and completely safe
FUSE RRIERS >>> Practical and completely safe Isolating fuse carriers 058 06 058 28 Dimensions (p. 0) onform to standard IE 60269-2/2. and to NF 63-2. Isolators conform to IE 60947-3. Icc: - 20 k with
More informationTMC 91H is now TMC 60 C Series
TMC 91H is now TMC 60 C Series The new Thermal Magnetic Circuit Breaker is once again available and better than ever! The new version is not only UL recognized with the same electrical performance as the
More informationSIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A
The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.
More informationSafety switches for hinges
Safety switches for hinges Selection diagram ACTUATORS L L6 L9 L16 FR FM FX FZ FK CONTACT BLOCKS 6 7 9 14 18 snap action 1NO+1N, make before break, shifted, close 21 4 66 NC 2NO+ 1NO+ CONDUIT ENTRIES Threaded
More informationFuse switch disconnectors
SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED
More informationSIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A
Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented
More informationControl Circuit Protection
Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC
More informationContents. Volume 5 Motor Control and Protection CA E December
Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions
More informationFL series position switches
FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable
More informationMULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole
MULTIBLOC 1.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 1.RST8 comprises NH fuse switch disconnectors for 250A. Products are designed in triple
More informationS200 UL 489 Series. Miniature circuit breakers S200. Features. Description
UL 489 Series UL 489 Series Description The Series miniature circuit breaker offers a compact solution for protection requirements. The U AND UP devices are UL 489 tested limiting and DIN rail mounted.
More informationSystem Benefits Should you have any further questions, please contact our UL hotline at: +49 (0)9563/ Connection Technology EQUES Technology
System Benefits The small external dimensions of the 60mm busbar system allow for a wide range of busbars, so that it can be easily adapted to a wide range of currents. These features result in the particularly
More informationvertical fuse switch disconnectors
SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -
More informationRX 3 M.C.B A up to 63 A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationNH Plastic bases. NH Plastic bases IEC NH FUSE BASES FEATURES & BENEFITS APPLICATIONS STANDARDS TECHNICAL DATA OVERVIEW
FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC NH FUSE BASES FEATURES & BENEFITS Polyester insulating bases Silver-plated contacts High-pressure spring contacts Screw or rail mounting Multipolar bases available
More informationCat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s 0090 00/01/02/06/07/11/12/13/14 0/01/02/06/07/11/12/13/14/18/19/23/24/25/26/ /18/19/23/24/25/26/45/46 45/46 0090
More informationSection Contents. Disconnect Switches
Section Contents Page Compact Circuit Protector (CCP) fused disconnect switches....................326-329 Fused, dead front disconnect switches...........329 Fusible Disconnect Switch Overview............330
More informationMCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics
Miniature circuit breakers General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for
More informationMicroswitches MK series
D Microswitches MK series Introduction Microswitches of MK series have been developed in order to add new features to traditional and tested microswitches of Pizzato Elettrica (cross-reference at page
More informationINNOVATION IS OUR POWER.
MANUAL 2019 EN INNOVATION IS OUR POWER. Wöhner develops system solutions for the electro-technical market. For over 90 years, the Wöhner name has been synonymous with impressive technical achievements
More informationStandard terminal blocks
T01005 001229 Standard terminal blocks DIN 1 - Spacing 6 mm + 0,05 (.28") M 4/6... Standard blocks Blue Orange Yellow Green ed Black White Brown Beige V0 Blue V0 M 4/6 0115 116.07 M 4/6.N 0125 116.01 M
More informationMicroswitches MK series
Microswitches MK series Microswitches of MK series have been developed in order to add new features to traditional and tested microswitches of Pizzato Elettrica. These products have been designed with
More information