M1 TYPE SLIM VARIABLE STATIC PRESSURE HIDE AWAY CONCEALED DUCT
|
|
- Peter Welch
- 5 years ago
- Views:
Transcription
1 VRF SYSTEMS M TYPE SIM VARIABE STATIC PRESSURE IDE AWAY CONCEAED DUCT The ultra slim M type is one of the leading products of its type in the industry. With a depth of only mm it provides greater flexibility and can be used in far more applications. In addition, its high-efficiency and extremely quiet sound levels make it very popular with many users, including hotels and small offices. Technical focus Ultra-slim profile: mm for all models DC fan motor greatly reduces power consumption Ideal for hotel application with very narrow false ceilings Anti-mould washable filters included Easy maintenance and service by external electrical box Pa static pressure enables ductwork to be fitted. Includes drain pump Ultra-slim profile for all models mm with increased power! By adoption of a high-lift drain pump, the drain piping rise height can be increased to mm from the lower surface of the body. Up to mm Up to mm OPTIONA CONTROER OPTIONA CONTROER OPTIONA CONTROER remote controller Wireless remote controller Simplified remote controller CZ-RTC CZ-RWSC CZ-REC MODE NAME S-MME S-MME S-MME S-MME S-MME Power source V / phase / z Cooling capacity kw..... Cooling power input W Cooling operating current A..... eating capacity kw..... eating power input W eating operating current A..... Fan Type Sirocco fan Sirocco fan Sirocco fan Sirocco fan Sirocco fan Air flow rate (/M/) m³/h / / / / / / / / / / External static pressure Pa () () () () () Sound pressure level (/M/) db(a) / / ( / / )¹ / / ( / / )¹ / / ( / / )¹ / / ( / / )¹ / / ( / / )¹ Dimensions x W x D mm x x x x x x x x x x Pipe connections iquid inches (mm) / (.) / (.) / (.) / (.) / (.) Gas inches (mm) / (.) / (.) / (.) / (.) / (.) Drain piping VP- VP- VP- VP- VP- Net weight Kg. With booster cable using short circuit connection. Energy saving Environmentally friendly refrigerant RA Easy maintenance SEF-DIAGNOSING For more comfort AUTOMATIC FAN Perfect humidity control MID DRY Practical operation AUTOMATIC RESTART Comfort everywhere AIR SWEEP Easy to install BUIT-IN DRAIN PUMP Easy control by BMS CONNECTIVITY Rating Conditions: Cooling Indoor ºC DB / ºC WB. Cooling Outdoor ºC DB / ºC WB. eating Indoor ºC DB. Cooling Outdoor ºC DB / ºC WB. DB: Dry Bulb; WB: Wet Bulb
2 WAY SYSTEM Unit Specifi cations. Slim ow Static Ducted Type (M Type) -. Specifications Unit specifications (A) MODE No. Indoor Unit S-MME - - V, single-phase, / z PERFORMANCE Cooling eating kw.. BTU / h,, Air circulation (i / Me / o) m / h / / Moisture removal (igh) iters / h. External static pressure (igh) Pa (.): At shipment (.): Using short circuit connection EECTRICA RATINGS Voltage rating V Available voltage range V - - Running amperes A Power input W Power factor % ON / OFF (Max. hr) and Automatic control Operation sound (i / Me / o) db-a / / Using short circuit connection (i / Me / o) db-a / / Refrigerant tube iquid tube mm (in.). ( / ) Gas tube mm (in.). ( / ) OD mm Max. head mm above drain connection DIMENSIONS & WEIGT Unit dimensions Package dimensions eight mm (in.) (- / ) (- / ) Unit dimensions Width mm (in.) (- / ) (- / ) Depth mm (in.) (- / ) (- / ) Net weight kg (lbs.) () Shipping weight kg (lbs.) () Shipping volume m (cu.ft). (.) DATA SUBJECT TO CANGE WITOUT NOTICE. Cooling: Indoor air temperature C DB / C WB; Outdoor air temperature C DB eating: Indoor air temperature C DB; Outdoor air temperature C DB / C WB -
3 WAY SYSTEM Unit Specifi cations. Slim ow Static Ducted Type (M Type) Unit specifications (B) MODE No. Indoor Unit S-MME - - V, single-phase, / z PERFORMANCE Cooling eating kw.. BTU / h,, Air circulation (i / Me / o) m / h / / Moisture removal (igh) iters / h. External static pressure (igh) Pa (.): At shipment (.): Using short circuit connection EECTRICA RATINGS Voltage rating V Available voltage range V - - Running amperes A Power input W Power factor % ON / OFF (Max. hr) and Automatic control Operation sound (i / Me / o) db-a / / Using short circuit connection (i / Me / o) db-a / / Refrigerant tube iquid tube mm (in.). ( / ) Gas tube mm (in.). ( / ) OD mm Max. head mm above drain connection DIMENSIONS & WEIGT Unit dimensions Package dimensions eight mm (in.) (- / ) (- / ) Unit dimensions Width mm (in.) (- / ) (- / ) Depth mm (in.) (- / ) (- / ) Net weight kg (lbs.) () Shipping weight kg (lbs.) () Shipping volume m (cu.ft). (.) DATA SUBJECT TO CANGE WITOUT NOTICE. Cooling: Indoor air temperature C DB / C WB; Outdoor air temperature C DB eating: Indoor air temperature C DB; Outdoor air temperature C DB / C WB -
4 WAY SYSTEM Unit Specifi cations. Slim ow Static Ducted Type (M Type) Unit specifications (C) MODE No. Indoor Unit S-MME - - V, single-phase, / z PERFORMANCE Cooling eating kw.. BTU / h,, Air circulation (i / Me / o) m / h / / Moisture removal (igh) iters / h. External static pressure (igh) Pa (.): At shipment (.): Using short circuit connection EECTRICA RATINGS Voltage rating V Available voltage range V - - Running amperes A Power input W Power factor % ON / OFF (Max. hr) and Automatic control Operation sound (i / Me / o) db-a / / Using short circuit connection (i / Me / o) db-a / / Refrigerant tube iquid tube mm (in.). ( / ) Gas tube mm (in.). ( / ) OD mm Max. head mm above drain connection DIMENSIONS & WEIGT Unit dimensions Package dimensions eight mm (in.) (- / ) (- / ) Unit dimensions Width mm (in.) (- / ) (- / ) Depth mm (in.) (- / ) (- / ) Net weight kg (lbs.) () Shipping weight kg (lbs.) () Shipping volume m (cu.ft). (.) DATA SUBJECT TO CANGE WITOUT NOTICE. Cooling: Indoor air temperature C DB / C WB; Outdoor air temperature C DB eating: Indoor air temperature C DB; Outdoor air temperature C DB / C WB -
5 WAY SYSTEM Unit Specifi cations. Slim ow Static Ducted Type (M Type) Unit specifications (D) MODE No. Indoor Unit S-MME - - V, single-phase, / z PERFORMANCE Cooling eating kw.. BTU / h,, Air circulation (i / Me / o) m / h / / Moisture removal (igh) iters / h. External static pressure (igh) Pa (.): At shipment (.): Using short circuit connection EECTRICA RATINGS Voltage rating V Available voltage range V - - Running amperes A Power input W Power factor % ON / OFF (Max. hr) and Automatic control Operation sound (i / Me / o) db-a / / Using short circuit connection (i / Me / o) db-a / / Refrigerant tube iquid tube mm (in.). ( / ) Gas tube mm (in.). ( / ) OD mm Max. head mm above drain connection DIMENSIONS & WEIGT Unit dimensions Package dimensions eight mm (in.) (- / ) (- / ) Unit dimensions Width mm (in.) (- / ) (- / ) Depth mm (in.) (- / ) (- / ) Net weight kg (lbs.) () Shipping weight kg (lbs.) () Shipping volume m (cu.ft). (.) DATA SUBJECT TO CANGE WITOUT NOTICE. Cooling: Indoor air temperature C DB / C WB; Outdoor air temperature C DB eating: Indoor air temperature C DB; Outdoor air temperature C DB / C WB -
6 WAY SYSTEM Unit Specifi cations. Slim ow Static Ducted Type (M Type) Unit specifications (E) MODE No. Indoor Unit S-MME - - V, single-phase, / z PERFORMANCE Cooling eating kw.. BTU / h,, Air circulation (i / Me / o) m / h / / Moisture removal (igh) iters / h. External static pressure (igh) Pa (.): At shipment (.): Using short circuit connection EECTRICA RATINGS Voltage rating V Available voltage range V - - Running amperes A Power input W Power factor % ON / OFF (Max. hr) and Automatic control Operation sound (i / Me / o) db-a / / Using short circuit connection (i / Me / o) db-a / / Refrigerant tube iquid tube mm (in.). ( / ) Gas tube mm (in.). ( / ) OD mm Max. head mm above drain connection DIMENSIONS & WEIGT Unit dimensions Package dimensions eight mm (in.) (- / ) (- / ) Unit dimensions Width mm (in.) (- / ) (- / ) Depth mm (in.) (- / ) (- / ) Net weight kg (lbs.) () Shipping weight kg (lbs.) () Shipping volume m (cu.ft). (.) DATA SUBJECT TO CANGE WITOUT NOTICE. Cooling: Indoor air temperature C DB / C WB; Outdoor air temperature C DB eating: Indoor air temperature C DB; Outdoor air temperature C DB / C WB -
7 WAY SYSTEM Unit Specifi cations. Slim ow Static Ducted Type (M Type) -. Dimensional Data Indoor unit: S-MME / MME / MME / MME / MME unit : mm Refrigerant tubing joint (narrow tube) Refrigerant tubing joint (wide tube) Upper and bottom drain port (O.D.mm) Suspension lug Power supply outlet (ø) Frange for air inlet duct Pl cover Electrical component box Filter Inter-unit control wiring and control wiring for group control outlet (ø) Remote control wiring outlet (ø) -ø. Water inlet Inspection access ( ) () (ole) -ø. (ole) ( x ) -ø. (ole) (Suspension bolt pitch) Frange for air inlet duct * Filter Uninstalled (Frange for air inlet duct) (Suspension bolt pitch) unit: mm -
8 WAY SYSTEM Unit Specifi cations. Slim ow Static Ducted Type (M Type) -. Noise Criterion Curves Both z and z Strong MODE : S-MME MODE : S-MME Weak SOUND EVE : STRONG db(a) SOUND EVE : STRONG db(a) WEAK db(a) WEAK db(a) CONDITION :. m directly below unit CONDITION :. m directly below unit (db =.µbar) (db =.µbar) (db =.µbar) Overall Frequency at center of sound pressure band (z) MODE : S-MME SOUND EVE : STRONG db(a) WEAK db(a) CONDITION :. m directly below unit NC- Approximate minimum continuous noise NC- Overall Frequency at center of sound pressure band (z) MODE : S-MME SOUND EVE : STRONG db(a) WEAK db(a) CONDITION :. m directly below unit Approximate minimum continuous noise Approximate minimum NC- continuous noise Overall Frequency at center of sound pressure band (z) REMARKS: NOTE NC- NC- NC- NC- NC- NC- NC- NC- NC- MODE : S-MME SOUND EVE : STRONG db(a) WEAK db(a) CONDITION :. m directly below unit To evaluate the noise level, the maximum value of the measured sound pressure level is used. Read the value at each frequency level (on horizontal axis, center of the sound pressure band) from z to z, and select the corresponding maximum value indicated on the vertical axis. - (db =.µbar) (db =.µbar). Value obtained in the actual place where the unit is installed may be slightly higher than the values shown in this graph because of the conditions of operation, the structure of the building, the backgroundnoise and other factors.. The test results were obtained from an anechoic room.. The layout of the testing condition is shown at right. Approximate minimum NC- continuous noise Overall Frequency at center of sound pressure band (z) Approximate minimum NC- continuous noise Overall Frequency at center of sound pressure band (z) Air discharge Auxiliary Duct of m length (ow Silhouette Ducted Type) Unit NC- NC- NC- NC- NC- NC-. m. m directly below unit Auxiliary Duct of m length Air intake
9 WAY SYSTEM Unit Specifi cations. Slim ow Static Ducted Type (M Type) -. Increasing the Fan Speed For Short Circuit Connection The standard (before shipment) external static pressure is shown in the table below. When using with a higher static pressure, it is necessary to change to the high static pressure mode. External static pressure Type Standard igh static pressure When using with high static pressure mode, set the indoor unit control board as shown at right. Follow the below procedure while the unit is turned off. () Open the cover of the electrical box and confirm that it is the indoor unit control board. () Connect the short circuit connector to the short circuit pin TP (P: Yellow) of the indoor unit control board. In case of wired remote control setting, do not use the short circuit connector. Indoor control board For Wired Remote Control Press and hold the, and buttons simultaneously for seconds or longer., unit No. (or in the case of group control), item code, and settings data are displayed blinking on the remote controller CD display. At this time, the indoor unit fan (or all indoor unit fans in the case of group control) begins operating. Press the temperature setting / buttons to select the item code. Press the timer time / buttons to select the desired setting data. * For item codes and setting data, refer to the right table. Press the button. (The display stops blinking and remains lit, and setting is completed.) Press the button to return to normal remote controller display. S-MME S-MME (Pa) External Static Pressure (Pa) External Static Pressure Airflow (m /minute) Airflow (m /minute) S-MME Airflow (m /minute) External Static Pressure (Pa) External Static Pressure (Pa) S-MME T - Airflow (m /minute) External Static Pressure (Pa) Item code External static pressure's upper limit in high static pressure mode Standard external static pressure's upper limit Airflow (m /minute) TP TP TP White Yellow Red TP TP TP No. Description ower limit airflow Airflow (m /minute) S-MME External Static Pressure (Pa) Standard (setting at shipment) igh static-pressure Upper limit airflow Rated external static pressure in high static pressure mode ower static pressure in high static pressure mode Rated external static pressure at shipment
VRF. Technical Data Book. Duct S for Europe (R410, 50Hz)
VRF Technical Data Book Duct S for Europe (R410, 50Hz) Version Modification Date Remark Ver.1.0 Release VRF DVM S IDU Duct S for Europe (R410A, 50Hz) TDB 14.09.22 Ver.1.1 External Pressure Minimum data
More informationVRF. Technical Data Book. DVM Indoor Unit PAC for Global (INV, R410A, HP) Model : AM140JNPDKH/TK (50/60Hz) AM280JNPDKH/TK (50Hz)
VRF Technical Data Book DVM Indoor Unit PAC for Global (INV, R410A, HP) Model : AM140JNPDKH/TK (50/60Hz) AM280JNPDKH/TK (50Hz) History Version Modification Date Remark Ver.1.0 Release DVM Indoor PAC for
More informationMSP Duct S Specifications
MSP Duct S Specifications Model Name AM022FNMDEH AM028FNMDEH AM036HNMPKH AM045HNMPKH AM056HNMPKH Capacity *2) 2.2 2.8 3.6 4.5 5.6 *3) 2.5 3.2 4.0 5.0 6.3 Perfomance (Total) *5) kw 1.8 2.3 2.9 3.7 4.6 VRF
More informationVMDA Concealed Medium Static Ducted Indoor Models - 60HZ
VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDA Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Slim, compact design for limited space requirements. Installs out of sight between the
More informationSINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU
SINGLE Technical Data Book Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU History Version Modification Date Remark Ver.1.0 Release SINGLE Big
More informationRESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS
RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS A Better Life, A Better World As we move towards our Centenary in 2018, our new brand slogan encapsulates Panasonic s
More informationVRF. Technical Data Book. Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH***
VRF Technical Data Book Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH*** History Version Modification Date Remark Ver.1.0 Release Ceiling for America (R410A, 60Hz, HP) 15.11.04 - 1 Nomenclature
More informationVMDB Concealed Medium Static Ducted Indoor Models - 60HZ
VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDB Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Bulletin No. 210711 March 2018 Slim, compact design for limited space requirements. Installs
More informationVHIA High-Static Ducted Indoor Units - 60HZ
PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage
More informationVersion Modification Date Remark
Version Modification Date Remark Products 1 Nomenclature... 2 Line-up... 3 Accessory... 1 Nomenclature 1-1. Nomenclature Model name AM RVX 45 1 HF TN T4 FD EE EH / EU 1 (Buyer) Classification AM DVM
More informationProduct Catalog. Variable Refrigerant Flow (VRF) VRF-PRC026A-EN. Mid-Static Concealed (Ducted) Indoor Units. November 2015
Product Catalog Variable Refrigerant Flow (VRF) Mid-Static Concealed (Ducted) Indoor Units Indoor Unit Model number: 4TVD****C***** November 2015 VRF-PRC026A-EN Introduction Trane variable refrigerant
More informationIndirect evaporative air conditioning 100% outside air FACTORY INSTALLATION (CW-160)
FACTORY INSTALLATION (CW-160) Indirect evaporative air conditioning 100% outside air About Climate Wizard Climate Wizard s unique indirect evaporative heat exchange core provides hyper-efficient cooling
More informationceiling wall AWYZ14LB/18LB With the world's first self-cleaning filter system
ceiling wall Large and wide airflow High efficiency Low noise Large centre display Easy maintenance Inverter options Automatic filter cleaning options Easy-to-use remote controller AWYZ14LB/18LB With the
More informationIndoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.
Indoor Console Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Black Display Functional art, the touch screen display is elegant
More informationVWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ
PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ Bulletin No. 210712 March 2018 Low-sound, three-speed Wall Mount with LED display offers three
More informationV33B High Efficiency 360 Cassette Indoor Models - 60HZ
PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven
More informationAir Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB
Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQA3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB TABLE OF CONTENTS FXDQ-A3 1 Features.............................................................
More informationtechnical data air conditioning systems Round Flow Cassette FXFQ-P9VEB
technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems TABLE OF CONTENTS FXFQ-P9VEB 1 Specifications.......................................................
More informationHigh Static Pressure Duct Fan Coil Unit
MCAC-KTSM-2012-03 High static pressure ducted FCU High Static Pressure Duct Fan Coil Unit 1. Introduction... 2 2. Nomenclature... 2 3. Product Schedule... 3 4. External Appearance... 3 5. Features... 4
More informationPREMIUM INVERTER DUCTED AIR CONDITIONING
PREMIUM INVERTER DUCTED AIR CONDITIONING PANASONIC LEADS THE WAY Ducted Air Conditioning Specialists With more than 30 years of experience, exporting to more than 120 countries around the world, Panasonic
More informationLow Static Pressure Duct(V shape evaporator)
Low Static Pressure Duct (V shape evaporator) 1. Features... 116 2. Specifications... 118 3. Dimensions... 121 4. Service Spaces... 123 5. Piping Diagrams... 124 7.Fan Performance... 126 8.Capacity Tables...
More informationSINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU)
SINGLE Technical Data Book 4Way Cassette S for Nordic (R4A, 5Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU) History Version Modification Date Remark Ver.1. Released SINGLE for Nordic TDB 15.3.. Ver.1.1
More informationV33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ
PRODUCT SPECIFICATIONS Low-sound, standard or high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has
More informationSINGLE. Technical Data Book. HSP Duct for America (R410A, 60Hz, H/P)
SINGLE Technical Data Book HSP Duct for America (R41A, 6Hz, H/P) Version Modification Date Remark Ver.1.4 Modified MCA 16.3.8 Ver.1.5 Modified Specifcation for MCA, Compressor oil type, Capacity Table,
More informationDC INVERTER VRF SYSTEMS C-VRF
DC INVERTER VRF SYSTEMS C-VRF Index VRF System Overview 4 C-VRF 9 Advantages 10 Benefits For Users 14 Benefits For Installers 18 C-VRF MINI 27 Advantages 28 Indoor Units 33 Indoor Units Line Up 34 Indoor
More informationCOMMERCIAL // HEATING AND COOLING SYSTEMS EVERY OFFICE MATTERS
2010 COMMERCIAL // HEATING AND COOLING SYSTEMS EVERY OFFICE MATTERS COMMERCIAL WELCOME TO COMMERCIAL RANGE Welcome to Commercial range. Welcome to healthier air. A range which confi rms its commitment
More informationCEILING CONCEALED SPLIT SYSTEM C SERIES
CEILING CONCEALED SPLIT SYSTEM C SERIES Microprocessor Controlled ith the microprocessor controlling the operation, the ACC model can offer comfortable room conditions according to the needs of the user.
More information1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...
MCAC-VTSM-2013-08 1. Features... 264 2. Specifications... 265 3. Dimensions... 268 4. Service Spaces... 272 5. Piping Diagrams... 273 6. Wiring Diagrams... 274 7. Capacity Tables... 276 8. Electrical Characteristics...
More informationTechnical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph
Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4
More informationLow Static Pressure Duct (V shape evaporator)
MCAC-VTSM-2015-04 Low Static Pressure Duct Type Low Static Pressure Duct (V shape evaporator) 1. Features... 100 2. Specifications... 101 3. Dimensions... 105 4.Service Spaces... 106 5.Piping Diagrams...
More informationPHCD-Series. Catalog
PCD-Series Catalog odel: PCD Introduction PCD fan coil unit is designed for a fully concealed ceiling installation. The external static pressure(esp) is up to 75Pa. Owing to its low static and low noise,
More informationCompact Four-way Cassette Type
1. Features... 34 2. Specifications... 35 3. Dimensions... 37 4. Service Spaces... 38 5. Piping Diagrams (EXV beside)... 39 6. Wiring Diagrams... 40 7. Capacity Tables... 41 8. Electrical Characteristics...
More informationVRF. Technical Data Book. DVM IDU_Vertical AHU for NA (R410A, 60Hz, HP) Model : AM***JNZDCH/AA
VRF Technical Data Book DVM IDU_ for NA (R4A, 6Hz, HP) Model : AM***JNZDCH/AA Version Modification Date Remark Ver.. Release DVM Indoor Unit_ TDB for America 5. 6.. Ver.. Modification for Heater kit (option)
More informationSINGLE. Technical Data Book. Big Ceiling for Europe (R410A, 50Hz, H/P)
SINGLE Technical Data Book Big Ceiling for Europe (R4A, Hz, H/P) Version Modification Date Remark Ver.1. Release SINGLE Big Ceiling for Europe (R4A, Hz, H/P) TDB 1.4.3 Ver.1.1 Modification for drain pipe
More informationVRF. For Commercial and Light Commercial
118 VRF For Commercial and Light Commercial 119 SOLUTIONS SMALL OFFICES Fujitsu General provides perfect total air conditioning systems that take into account energy saving, low noise, comfortable airflow,
More informationCeiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary
Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature
More informationMidea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual
Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without incurring
More informationERV. Technical Data Book. ERV for Europe (NASA, 50Hz, 60Hz)
Technical Data Book for Europe (NASA, Hz, Hz) History Version Modification Date Remark Ver.1. Released TDB 15.5.11 Ver.1.1 Add Note information in Specification regarding EU F-Gas regulation 15.6.16 Index
More informationTechnical Service Manual
Technical Service Manual 60 Hz Low/Mid Pressure Duct Units 7 48 MBH Units 96 MBH Unit June 2009 VRF-SVM21A-EN Low and Mid Pressure Duct Units 1. Features......... 2 2. Specifications......... 3 3. Dimensions.........
More informationVRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series
VRF Indoor Unit 50Hz Type: Wall Mounted M Series Wall Mounted S Series Contents 01 Wall Mounted M Series 20 Wall Mounted S Series MCAC-VTSM-2016-05 Wall Mounted M Series Wall Mounted M Series 1. Features...
More informationTechnical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph
Technical Service Manual TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 2015 1. Features...2 2. Specifications...3 3. Dimensions...7 4.Service Spaces...8 5.Piping
More informationRESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONING
RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONING Panasonic Air Conditioning Designed To Care For Your Projects Since the sale of Panasonic s room air conditioner in 1958, we have worked towards providing
More informationR410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2
R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1
More informationDuctless Split Systems
Ductless Split s Right Product for the Right Application September 2014 Ductless Split s Right Product for the Right Application Single-Zone s Multi-Zone s (up to five rooms) High Wall High Wall, Cassette,
More information1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units
t i t l r - I Features s e Cs m B ne d E Ue V s 7 ya P os e oc Q dvn S nr ox VF C Reduction of power consumption of 20% (compared to FXSQ-M8 series) through use of new DC fan Improved comfort thanks to
More informationVersion Modification Date Remark
Version Modification Date Remark Index 1 Nomenclature 2 Specifications 3 Capacity table 4 Dimensional drawing 5 Electrical wiring diagram 6 Sound pressure level 7 Temperature and air flow distribution
More informationDuctless Split Systems
Ductless Split s Right Product for the Right Application Ductless Split s Right Product for the Right Application 1:1 2:1 to 5:1 High Wall High Wall, Cassette, Underceiling 2:1 to 5:1 High Wall Up to 23.0
More informationINVERTER DUCTED SYSTEMS
INVERTER DUCTED SYSTEMS What you ll find inside: DC Twin-Rotary Compressor Inverter Ducted advantages Controllers Product specifications Energy Efficient Powerful Operation Flexible Application 1 About
More informationModel RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2
2-8 GENERAL DATA 2.3. INVERTER SERIES 2.3.1. INVERTER (RAS-25YHA2/35YHA3/50YHA2/60YHA2/70YHA2/80YHA2) Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2 Power Supply From Outdoor Unit
More informationOthers ( 50Hz areas ) ADVANCED SUBJECT DATE: Sep 12 PRODUCT NEWS Launching of new RPI-(2.0~6.0)FSN4E ducted indoor units series.
PRODUCT S Launching of new RPI-(2.0~6.0)FSN4E ducted indoor units series. PAGE 1/7 Suary This Advanced Products News introduces the launching of new RPI-(2.0~6.0)FSN4E ducted indoor units series driven
More informationEngineering Data Book
40VMM Medium Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More information42HS Fan Coil Unit (High Static Pressure)
42S Fan Coil Unit (igh Static Pressure) Air Volume: 1360~3400m3/h Turn To The Experts Founded by the inventor of modern air conditioning, Carrier is the world s leader in high-technology heating, air-conditioning
More informationDUCTED INDOOR UNIT ENGINEERING MANUAL
EM_MultiV_Ducted_IndoorUnits_4_16 DUCTED INDOOR UNIT ENGINEERING MANUAL High Static Ducted 7,500 to 95,900 Btu/h Low Static Ducted 7,500 to 24,000 Btu/h Low Static Built In Ducted 7,500 to 24,200 Btu/h
More information2010 Duct-Free Splits Line Card
2010 Duct-Free Splits Line Card Right Product for the Right Application 2010 Duct-Free Splits Right Product for the Right Application 1:1 2:1 to 4:1 9-24K High Walls 18-24/6/42/60K High Wall, Cassette,
More informationDuctless Split Systems
Ductless Split s Right Product for the Right Application Ductless Split s Right Product for the Right Application 1:1 2:1 to 5:1 9-24K High Walls 18-24/6/42/60K High Walls, Cassette, Underceiling 2:1 to
More informationLARGE CAPACITY AIR CONDITIONERS 2012 / EVERy BUILDING MATTERS
LARGE CAPACITY AIR CONDITIONERS 2012 / 2013 EVERy BUILDING MATTERS Panasonic Air Conditioning Designed To Care For Your Projects With more than 30 years of experience, exporting to more than 120 countries
More informationCeiling Mount Type Ventilating Fan
Ceiling Mount Type Ventilating Fan Introduction 11-12 DC Motor Series 13-14 Super Quiet Series 15-18 Standard Series 19 10 These fans are installed in the ceiling connected with ductwork, by which indoor
More informationAir Conditioning. Technical Data. Wall mounted unit EEDEN FTX-GV
Air Conditioning Technical Data Wall mounted unit EEDEN15-100 FTX-GV TABLE OF CONTENTS FTX-GV 1 Features............................................................. 2 2 Specifications.......................................................
More informationHigh Performance Fan Coils FCHG Genesis Series Horizontal
Dimensional Data 5 7 /8 (150) D 14 (356) 2 (51) Diverter - Slides Into Discharge Ductwork Optional: Second Drain Pan Connection E Coil Section X Dimensional Data - IP (in.) / SI [mm] Unit Fan Outlet Duct
More informationTotal cooling capacity kw Total heating capacity kw Features
Room Fan Coils Idrofan Quality Management Systems 42N Total cooling capacity 0.75-6.35 kw Total heating capacity 0.60-9.50 kw The new generation 42N_S product range combines aesthetic and attractive design
More information42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION
PRODUCT SELECTION DATA EASY INSTALLATION INSTALLATION, OPERATION AND CENTRAL AIR DIFFUSION MAINTENANCE INSTRUCTIONS LOW ENERGY CONSUMPTION IMPROVED COMFORT ELEGANT AIR INLET GRILLE EXTREMELY QUIET OPERATION
More informationCapacity Tables. Cooling Capacity: Cooper&Hunter Wall Mounted FCU
Cooling Capacity: Remark: EWT: Enter Water Temp. ( ); Δt: Temperature Difference ( ) DB: Dry Bulb Temp. ( ); WB: Wet Bulb Temp. ( ); TC: Total Cooling Capacity (kw); SC: Sensible Cooling Capacity (kw);
More informationSUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP
VEP075N432K Job Name: Location: Schedule No.: System Designation: Engineer: Architect: Date: For: Reference Approval Review Construction FEATURES Two-pipe heat pump Hinged electrical box for ease of maintenance
More informationHigh Wall Type ( 2 Series )
Jan.05' Engineering Data High Wall Type ( 2 Series ) Indoor Unit MMK-AP0072H MMK-AP0092H MMK-AP0122H 1. Equipments 2. Technical Specifications 3. Dimensional Drawing 4. Wiring Diagram 5. Refrigerant Cycle
More informationDuctless Split Systems
Ductless Split s Right Product for the Right Application Ductless Split s Right Product for the Right Application 1:1 2:1 to 4:1 9-24K High Walls 18-24/6/42/60K High Wall, Cassette, Underceiling 2:1 to
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationHIGH STATIC FAN COIL UNITS
STATIC FAN COI UNITS District Cooling Chilled Water Application TECNICA CATAOGUE (DUCTED TYPE) GFC - D SERIES COOING CAPACITY RANGE: 10,407 TO 66,329 BTU/R CASSIFIED INSUATION & FITER EDIA GFC-D-TC-10-13
More informationDC INVERTER DUCTED AIR CONDITIONERS
DC INVERTER DUCTED AIR CONDITIONERS DC Inverter Ducted Air Conditioners Technology. With over 5% of revenue invested in research and development programs, Hitachi has developed world leading technologies
More informationVersatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits
Ultra quiet and low profile helicocentrifugal in-line fans suitable for a wide range of domestic and commercial applications. Fitted with sound absorbent insulation and manufactured with an adjustable
More informationDriving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan
Driving and Connecting Globally Fan Coil Unit : PHW-K Size : 510CMH~2720CMH Made in Taiwan Features Superior low-height design. Stainless steel drain pan for condensate and corrosion protection. Flexibe-reverse
More informationNew ECOi Electric 2 and 3 pipe VRF systems. 2006/7 Range. All round air conditioning by
New ECOi Electric 2 and 3 pipe VRF systems 2006/7 Range 1 All round air conditioning by ECOi the next generation of 2 and 3 pipe electric SANYO is justifi ably proud of being renowned for developing unique
More informationService manual MIV V4+ Indoor units
Service manual MIV V4+ Indoor units Floor Standing MVF22A-VA1 MVF28A-VA1 MVF36A-VA1 MV5A-VA1 MVF56A-VA1 MVF71A-VA1 MVF80A-VA1 MVB22A-VA1 MVB28A-VA1 MVB36A-VA1 MVB45A-VA1 MVB56A-VA1 MVB71A-VA1 MVB80A-VA1
More informationStylus 4G. Mini Split Air Conditioners. Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a
Stylus 4G Mini Split Air Conditioners Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a Stylus 4G Comfort Solutions Trane proudly presents the Stylus 4G air conditioners
More informationTechnical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.
Technical Support Division 2012.10 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics
More informationEngineering Data Book
40VMA Outside Air Processing Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationProduct Data. 42D Ducted Fan Coil Air Conditioners cfm
Product Data 42D Ducted Fan Coil Air Conditioners 600-2000 cfm Carrier s 42D series ducted fan coil units offer design and equipment location flexibility Choice of 5 models, each available in 8 sizes For
More informationFDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E
R407C TECHNICAL MANUAL Split Systems Air Conditioner Ducted Blower D & E Series FDMP-D, FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E series Cooling only & Heatpump [50Hz] Table of Contents Table of Contents
More informationROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh
ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered
More informationMAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional
Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed
More informationSUBMITTAL DATA: MXZ-5C42NAHZ MULTI-INDOOR INVERTER HEAT PUMP SYSTEM. Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz
M-SERIES SUBMITTAL DATA: MXZ-5C42NAHZ MULTI-INDOOR INVERTER HEAT PUMP SYSTEM Job Name: System Reference: Date: Outdoor Unit: MXZ-5C42NAHZ ACCESSORIES Three-port Branch Box (PAC-MKA30BC) Five-port Branch
More informationS6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.
TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,
More informationPrecision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz
Precision Cooling For Business-Critical Continuity Liebert CW System Design Manual - 26-181kW, 50 & 60Hz TABLE OF CONTENTS LIEBERT CW MODEL NUMBER NOMENCLATURE....................................1 1.0
More informationPHR5. Product Specifications
PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R
More informationDVM. Technical Data Book
DVM Technical Data Book Outdoor Units I. Products 1 2 3 Outdoor units Indoor units Accessories 6 7 9 2 II. Outdoor units 1 2 3 4 5 6 Specifications Operation limit Electrical wiring diagram Sound level
More informationPACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.
TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor
More informationSplit-Sky Air FAYP-B Wall Mounted Unit
TECHNICAL DATA Split-Sky Air FAYP-B Wall Mounted Unit Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential
More informationDuctless Systems. Right product for the right application. Fall 2015 Edition
Ductless Systems Right product for the right application Fall 2015 Edition Right Product for the Right Application Single Zone - Residential Single Zone - Light Commercial Multi-Zone RAV-**KRT System High
More informationSILENT MV Ultra Quiet In-line Fans
Ultra Quiet In-line Fans 5 IP44 2 YEAR GUARANTEE Ultra quiet and low profile helicocentrifugal in-line fans suitable for a wide range of domestic and commercial applications. Fitted with sound absorbent
More informationVRF Technical Data Book
VRF Technical Data Book DVM S Eco for America (R410A, 60Hz, HR) Model : AM***NXMDCR/AA History Version Modification Date Remark Ver.1.0 Released DVM S Eco HR for North America TDB 18.02.28 Ver.1. Re 18.0
More informationTechnical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.
Technical Support Division 2013.12 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics
More informationConcealed Ducted Split Series R22
Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING
More informationFFQN-C, FCRN-E, FFRN-C
R410A TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FCQN-E, FFQN-C, FCRN-E, FFRN-C Cooling only & Heatpump [50Hz] DAIKIN_FFRN.indb i 12/27/2012 9:28:06 AM DAIKIN_FFRN.indb ii
More information42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM
42CLS-W Series Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM World's No.1 Air Conditioning Expert www.carrier.co.th 42CLS-W Series Furred-in ceiling model 400-0 cfm The low silhouette
More informationDuctless F L EXIBIL ITY IS F R EEDOM. Fl ex Fit d uc t l ess system. Higher Comfort, Haier Living
Ductless F L EXIBIL ITY IS F R EEDOM I n t ro d uc in g t h e H a ie r Fl ex Fit d uc t l ess system A What is FlexFit? FlexFit is a top-of-the-line modular system that allows for optimal ductless pairings
More informationContents. Carrier China
42CE Fan Coil Unit Carrier China Headquartered in Farmington, Connecticut, USA, Carrier Corporation is the world's largest provider of heating, air conditioning and refrigeration solutions, with operations
More informationNEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only
NEW Wall controls Fan Coil Units www.euroventcertification.com www.certiflash.com Technical Guide for internal distribution only CONTENTS Construction Page 4 s Page 5 Dimension, Weight, Water content Page
More informationVITALITY Centrifugal Large Split
VITITY entrifugal arge Split V-VIR 20 to 90 complete range from 16.8 kw up to 87.3 kw Y2open eatures ew Y2open board igh efficiency R and P conomizer or motorized damper Indoor air quality ot water coil
More informationPRODUCT LINEUP VRF For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL
IRSTGE Systems can be designed to create an air conditioning solution to suit most buildings requirements. IRSTGE Systems can be designed to effectively provide an air conditioning solution from a large
More informationCarisma The Ultra Quiet Fan Coil
Carisma The Ultra Quiet Fan Coil Air Conditioning Carisma / CRR Fan Coil Units Quality management systems SO 900 Cert. n 0545/4 www.euroventcertification.com www.certiflash.com CONTENTS Construction ()
More informationIN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series
Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 16 to 8 models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from 1 to
More information