Size: px
Start display at page:

Download ""

Transcription

1 4000-Series ir Handling Systems ooling, Energy Recovery, Heating & Pressurization Dimension and Selection Guide ND: 100% OUTSIDE IR ONLY

2 4000-Series Fan Selection hart irflow-ubic Feet per Minute (FM) Discharge Velocity Feet per Minute (FPM) Required Motor Horse Power Noted External Static Pressure (in wc) rake Horse Power Noted External Static Pressure (in wc) d Noted External Static Pressure (in wc) , , F F F F 65 6, , , , , , , , , , , , F F F F F F F F F F F F 71 12, , F F F F 73 15, , , , F F F F 74 17, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , lass II Wheels F = ontact Factory See Page 3 and 4 for Important Notes. 2

3 irflow-ubic Feet per Minute (FM) Discharge Velocity Feet per Minute (FPM) Required Motor Horse Power Noted External Static Pressure (in wc) 4000-Series Fan Selection hart rake Horse Power Noted External Static Pressure (in wc) d Noted External Static Pressure (in wc) , , , , , , F F F F 75 60, , , , , , , , F F F F F F F F 72 65, , , , , , F F F F F F 74 70, , , , , , F F 76 75, , , , , , , , F F F F F F F F 73 80, , , , , , , , F F F F F F 75 85, , , , , , F F 76 90, , , , , , , , , , , , , , , , , , , , , , , , , , , * 2, , * 3, *Denotes MU configuration only lass II Wheels F = ontact Factory See Page 3 and 4 for Important Notes. IMPORTNT NOTES: Sound levels are in d at 5' from the discharge opening. This figure does not account for attenuation, additional noise or directivity factors. Motor horsepower required includes both the running HP and the starting torque requirements. HP can be greater than the standard fan curve charts. rake HP does not include drive losses. For external static pressure greater than 2", contact your local representative or Rapid Engineering LL. For operation in altitudes exceeding 2000' above sea level, contact the factory. The recommended motor horsepowers shown for the Fan Selection hart include fan and burner static pressure only (internal equipment static pressure). Other cabinet options could add static pressure and should be included in the external static pressure used to select motor horsepower. See the Static Pressure Drops on page 4 for the external static pressures that should be added for selected options. 3

4 urner Selection hart irflow - ubic Feet per Minute (FM) urner apacity hart Gas Flow - ubic Feet per Hour (FH) for Stated Temperature Rise 40 F 50 F 60 F 70 F 80 F 90 F 100 F 110 F 120 F 5, , ,125 7, ,125 1,125 8, ,125 1,125 1,125 1,125 9, ,125 1,125 1,125 1,500 10, ,125 1,125 1,125 1,500 1,500 12, ,125 1,125 1,125 1,500 1,500 1,500 1,875 15, ,125 1,125 1,125 1,500 1,500 1,875 1,875 2,250 17, ,125 1,125 1,500 1,500 1,875 1,875 2,250 2,250 20,000 1,125 1,125 1,500 1,500 1,875 2,250 2,250 2,625 2,625 22,500 1,125 1,500 1,500 1,875 2,250 2,250 2,625 2,625 3,000 25,000 1,125 1,500 1,875 1,875 2,250 2,625 2,625 3,000 3,375 30,000 1,500 1,875 2,250 2,250 2,625 3,000 3,375 3,750 4,125 35,000 1,500 1,875 2,250 2,625 3,000 3,375 3,750 4,125 4,500 40,000 1,875 2,250 2,625 3,000 3,375 4,125 4,500 4,875 5,250 45,000 2,250 2,625 3,000 3,375 4,125 4,500 4,875 5,250 6,000 50,000 2,250 2,625 3,375 3,750 4,500 4,875 5,250 6,000 6,375 55,000 2,625 3,000 3,750 4,125 4,875 5,250 6,000 6,375 7,125 60,000 2,625 3,375 4,125 4,500 5,250 6,000 6,375 7,125 7,875 65,000 3,000 3,750 4,125 4,875 5,625 6,375 7,125 7,500 8,625 70,000 3,000 3,750 4,500 5,250 6,000 6,750 7,500 8,250 9,000 75,000 3,375 4,125 4,875 5,625 6,375 7,125 7,875 9,000 9,750 80,000 3,375 4,500 5,250 6,000 6,750 7,875 8,625 9,375 10,500 85,000 3,750 4,500 5,625 6,375 7,500 8,250 9,000 10,125 10,875 90,000 4,125 4,875 6,000 6,750 7,875 8,625 9,750 10,875 11,625 95,000 4,125 5,250 6,000 7,125 8,250 9,375 10,125 11,250 12, ,000 4,500 5,250 6,375 7,500 8,625 9,750 10,875 12,000 13, ,000 4,875 6,000 7,125 8,250 9,375 10,500 12,000 13,125 14, ,000 5,250 6,375 7,875 9,000 10,500 11,625 13,125 14,250 15, ,000 5,625 7,125 8,250 9,750 11,250 12,750 13,875 15,375 16, ,000 6,375 7,875 9,750 11,250 12,750 14,625 16,125 17,625 19, F temperature rise is not ETL listed. Greater than 100 F temperature rise is not ETL listed when LPG is the fuel. Static Pressure Drops for Options Description in wc Description in wc Moisture Limiter For Horizontal Inlet Hood 0.10 luminum Mesh Filters For Horizontal Inlet Hood 0.15 Upright Stand with Polyester Filters (FR) 0.25 Outside ir Filter Section, No Filters 0 Filtered Mixing ox, No Filters 0 Filters - Polyester 0.25 Filters - luminum Mesh 0.15 Filters - 30% Pleated 0.25 ustom Filter Options (ag, artridge, HEP) F Evaporative ooling Section (EM) 0.25 Evaporative ooling Section (EM-D) 0.50 ooling oil Section 0.10 ooling oil F Damper - Inlet 0.05 Damper - Low Leak 0.05 Damper - Discharge 0.10 Damper - Discharge, Low Leak 0.10 End Discharge 0.20 Discharge Plate 0.05 Discharge Head - One Way 0.10 Discharge Head - Three Way 0.10 Discharge Head - Four Way 0.05 Horizontal Inlet Hood 0.00 Horizontal Inlet Plenum 0.10 Upright Inlet Plenum ase 0.05 Energy Recovery See Pg. 10 IMPORTNT NOTE: alculate the static pressure for selected cabinet options plus any ductwork. Use external static pressure column found in Fan Selection hart on pages 2-3 to determine motor horsepower. 4

5 Manifold Selection harts DIRETIONS: Select a point on the chart that represents the intersection of the inlet gas pressure and the unit cubic feet per hour (FH). Select the manifold size to the right of this point. For inlet supply gas pressure exceeding 5 PSI, an additional gas regulator is required. Natural Gas Flow vs. Required Inlet Pressure using an NP1-LE burner Required Gas Pressure at Manifold Inlet (in wc) with 4 Modulating Regulating Valve Required Gas Flow in ubic Feet per Hour (FH) = Gas Train Size Natural Gas Flow vs. Required Inlet Pressure using an NP2-LE burner Required Gas Pressure at Manifold Inlet (in wc) with 4 Modulating Regulating Valve Required Gas Flow in ubic Feet per Hour (FH) = Gas Train Size 5

6 Evaporative ooling Formulas bbreviations 1 Leaving Dry ulb = OD [SE* x (OD - OW)] Leaving Wet ulb = Entering Wet ulb (actually, it s slightly less than the 2 entering wet bulb, but is normally considered equal.) 3 Wet ulb Depression = OD OW 4 Evaporation Rate (GPH) = FM x WD x SE/ leed-off Rate = approximately 20% of evaporation rate* 6 Recirculation Rate = approximately 3 times evaporation rate* * leed-off and recirculation rates will vary with locale, water quality and chemical treatment program. These values are only for approximation. IMPORTNT NOTE: Refer to saturation efficiency table below. FM GPH ID LD LW OD OW SE WD ubic Feet Per Minute Gallons Per Hour Indoor (Design) Dry ulb Temperature Leaving Dry ulb Temperature Leaving Wet ulbtemperature Outdoor (Design) Dry ulb Temperature Outdoor (Design) Wet ulb Temperature Saturation Efficiency of the Evaporative Media Wet ulb Depression Wet ulb Depression ( F) Evaporation Rate - Gallons per Hour (GPH) Per 1,000 ubic Feet per Minute (FM) at Stated Saturation Efficiency Heat of vaporizaton = 1043 TU/lb Weight of water = 8.34 lb./gallon GPH = FM x WD x SE x 1.08/1043/8.34 = FM x WD x SE/8050 Suggested ir hanges Per Hour (ir hange Method) Leaving ir Temperature ( F D) Indoor ir Temperature bove mbient ( F)* ir hanges/ Hour** < 72 < * For existing buildings: verage amount indoor temperature exceeds ambient outdoor temperature when evaporative cooling is not in use. ** Experience has shown that significant benefit can be achieved with ir hanges per Hour (/Hr) through the lowest 12' of the facility. For a 24' high building, this would mean 5-6 ir hanges per Hour (/Hr) for the entire volume. This will vary by application. irflow- Feet per Minute (FPM) Saturation Efficiency at Stated Media Depth (in) 6" 8" 12" 18" 24" irflow- Feet per Minute (FPM) Static Pressure Drop (in wc) at Stated Media Depth (in) 6" 8" 12" 18" 24" IMPORTNT NOTE: Moisture limiter pressure drop is added for face velocities greater than 600 Feet per Minute (FPM). Rapid Engineering LL's standard media thickness equals 12". 6

7 Evaporative ooling LD 66 D/UD O RD PLN VIEW FN SETION URNER SETION OIL SETION EVPORTIVE OOLER ENERGY REOVERY SETION FILTER SETION INLET PLENUM OR INLET HOOD UD LD/RD O D ir Density Ratio ELETRIL ONNETION R GS ONNETION IMPORTNT NOTES: For unit dimensions, see pages 12, 14, 18. For legends, see pages 13, 15, 17, 19. ll dimensions are in inches and all weights are in pounds. ll dimensions and weights are subject to change without notice. pplicable abinet 550 FPM Max FM pplicable abinet 750 FPM Max FM IMPORTNT NOTE: Evaporative ooling Section is 42". Transition section is 24". Total length is 66". pplicable for MU/M/VV styles only. Dimensions 4024 EM24 4, EM24D 5, EM36 10, EM36D 13, EM40 12, EM40D 16, EM44 14, EM44D 19, EM49 17, EM49D 24, EM54 23, EM54D 31, EM60 28, EM60D 38, EM66 31, EM66D 43, EM73 34, EM73D 46, EM80 / EM89 48, EM- 80D / EM89D Leaving Dry ulb Temperature Drop [verage] Wet ulb Depression ( F) Temperature Drop ( F) For Stated Media Depth (in) 6" 8" 12" 18" 24" IMPORTNT NOTE: Rapid Engineering LL's standard media thickness equals 12". Density Ratio For Stated Elevation (ft/in HG) Temperature ( F) 0/ ,000/ ,000/ ,000/ ,000/ ,000/ ,000/ ,000/ ,000/ ,000/ ,000/ IMPORTNT NOTE: Table to be used when calculating total tonnage of cooling adjusted for elevation. 65, RIGHT SIDE VIEW 7

8 Mechanical ooling LD EE D/UD O RD PLN VIEW FN SETION URNER SETION OIL SETION EVPORTIVE OOLER ENERGY REOVERY SETION FILTER SETION INLET PLENUM OR INLET HOOD UD LD/RD DD O D ELETRIL ONNETION R GS ONNETION RIGHT SIDE VIEW IMPORTNT NOTES: For unit dimensions, see page 12, 14, 18. For legends, see pages 13, 15, 17, 19. ll dimensions are in inches and all weights are in pounds. ll dimensions and weights are subject to change without notice. irflow - ubic Feet per Minute (FM) ompatible abinet Sizes Range Of vailable Tons Of ooling Quantity Of oils Square Feet Fin rea (L x H) Of Each oil (in) oil Face Velocity Width Height Length Low High DD EE 8 3,000-7, x ,001-10, x ,001-20, x ,001-27, x ,501-30, x ,001-35, x ,001-50, x ,001-60, x ,001-65, x irflow - ubic Feet per Minute (FM) 0% O/ 100% R 25% O/ 75% R 50% O/ 50% R 75% O/ 25% R Estimated tons of cooling required to achieve 55/54 leaving air condition (chart based on O conditions of 94/74 and R conditions of 80/67) 100% O/ 0% R 5, , , , , , , , , , , , , , ,

9 Steam/Hot Water oils LD D/UD O RD PLN VIEW FN SETION URNER SETION OIL SETION EVPORTIVE OOLER ENERGY REOVERY SETION FILTER SETION INLET PLENUM OR INLET HOOD UD LD/RD O D ELETRIL ONNETION R GS ONNETION RIGHT SIDE VIEW IMPORTNT NOTES: For unit dimensions, see page 12, 14, 18. For legends, see pages 13, 15, 17, 19. ll dimensions are in inches and all weights are in pounds. ll dimensions and weights are subject to change without notice. oil section weights listed below do not include the internal coil weight. The weights shown below are for the housings only. onsult factory for complete coil section weights. Maximum FM pplicable Length Width 10, , , , , , , , , Weight 1,125 1,400 9

10 Energy Recovery LD D/UD O RD PLN VIEW FN SETION URNER SETION OIL SETION EVPORTIVE OOLER ENERGY REOVERY SETION FILTER SETION INLET PLENUM OR INLET HOOD UD LD/RD O D ELETRIL ONNETION GS ONNETION RIGHT SIDE VIEW IMPORTNT NOTES: For unit dimensions, see page 12, 14, 18. For legends, see pages 13, 15, 17, 19. ll dimensions are in inches and all weights are in pounds. ll dimensions and weights are subject to change without notice. pplicable irflow - ubic Feet per Minute (FM) Dimensions Length Width Height MU M Module Inlet Hood Estimated Weights Exhaust Fan Exhaust Hood Downturn Section Filter Housing ,000-7, , ,001-15, , ,001-20, , ,001-25, , ,001-30, , ,001-35, , , ,001-40, , , ,001-50, , , , ,001-60, , , ,

11 ompatible abinet Size Supply/ Exhaust ir - ubic Feet per Minute (FM) Pressure Drop (in wc) Energy Recovery Performance Efficiency ir Velocity Supply (face/channel) (ft/min) MU M Supply Exhaust Supply Exhaust Supply Exhaust , % 59% / / , % 60% / 1, / 1, , % 59% / 1, / 1, , % 59% / 1, / 1, , % 61% / / , % 61% / / , % 61% / / , % 61% / / , % 61% / / 1, , % 61% / 1, / 1, , % 61% / 1, / 1, , % 61% / 1, / 1, , % 61% / 1, / 1, , % 61% / 1, / 1, , % 60% / 1, / 1, , % 60% / 1, / 1, , % 60% / 1, / 1, , % 60% / 1, / 1, , % 60% / 1, / 1, , % 60% / 1, / 1, , % 60% / 1, / 1, , % 60% / 1, / 1, , % 60% / 1, / 1, , % 59% / 1, / 1, , % 59% / 1, / 1, , % 60% / 1, / 1, , % 60% / 1, / 1, , % 60% / 1, / 1, , % 59% / 1, / 1, , % 59% / 1, / 1, , % 59% / 1, / 1, , % 60% / 1, / 1, , % 60% / 1, / 1, , % 60% / 1, / 1, , % 59% / 1, / 1, , % 59% / 1, / 1, , % 59% / 1, / 1, , % 60% / 1, / 1, , % 60% / 1, / 1, , % 59% / 1, / 1, , % 59% / 1, / 1, , % 59% / 1, / 1, , % 59% / 1, / 1, , % 60% / 1, / 1, , % 60% / 1, / 1, , % 60% / 1, / 1, , % 59% / 1, / 1, , % 59% / 1, / 1, , % 59% / 1, / 1, , % 60% / 1, / 1, , % 60% / 1, / 1, , % 60% / 1, / 1, , % 59% / 1, / 1, , % 59% / 1, / 1, , % 59% / 1, / 1,

12 4000 M Horizontal See page 8/9 for coil section dimensions See page 7 for evaporative cooler dimensions See page 10 for energy recovery dimensions K J L LD D E N R T V V H & (H1) LR R Y Z M D/UD R P G R P X O K RD R N R T PLN VIEW RR FN SETION URNER SETION OIL SETION EVPORTIVE OOLER ENERGY REOVERY SETION FILTER SETION OR FILTER MIX OX INLET PLENUM OR INLET HOOD S UD Q LD/RD RR/LR P1 O F D ELETRIL ONNETION R GS ONNETION R N1 R1 S RIGHT SIDE VIEW Dimensions Width ir Handler Height Length ase Frame Formed hannel ase Frame Structural ngle Filter Section Width Filter Mixbox Length Filter Mixbox Length With Side Return Discharge Length Discharge Width Return ir Length Return ir Length Return ir Width Return ir Height Discharge Height Filter Section Length Plenum Width Plenum Length Inlet Hood Length Minimum Leg Height Plenum Height D E F G H H1 J K L M N N1 P P1 Q R R1 S T V X Y Z

13 4000 M Upright LEGEND O = Outside ir = ontrol Enclosure D = ottom Discharge LD = Left Discharge RD = Right Discharge UD = Up Discharge R = ottom Return RR = Right Return LR = Left Return = Field Joint (s ) = ccess Door (s 4080 & 4089) = ccess Door (s ) IMPORTNT NOTES: ll dimensions are in inches. ll weights are in pounds. ll dimensions and weights are subject to change without notice. Dimensions apply to both horizontal and upright units. Filters are shipped loose. Legs are shipped loose. ontrol enclosure for 3" or smaller manifolds is 57" H x 57" W x 25" D. ( dimension of 4024 cabinet size is approximately 20" smaller than the control enclosure control enclosure is 57" H x 57" W x 20" D.) To minimize the potential for water entrainment, an inlet hood with moisture limiter ir inlet plenum may be desirable. Outdoor air duct size varies. onsult Rapid Engineering LL. ontrol enclosure can be located on left or right side of unit. (Shown on right side in drawings) F D ELETRIL ONNETION R GS ONNETION R Q RD/LD O RIGHT SIDE VIEW S UD FN SETION URNER SETION SERVI PLTFORM FILTER SETION OR FILTER MIX OX RIN SKIRT (STNDRD FOR OUTDOOR EQUIPMENT) LEGS T N K M K J RD R D/UD R P G R LD R P R O FRONT VIEW R L N V V T H D E Horizontal Fan Section Horizontal urner Section Estimated Shipping Weights Horizontal Service Platforms Filter Filter Section Mixbox asic With O* dd With FM** dd Inlet Hood Inlet Plenum Upright Service Platform Upright Fan Section Upright urner Section , , , , , , , , , , , , , ,383 1, , , ,373 1, ,673 1, , , , ,961 2, , , ,129 2, ,219 2, ,125 2, , ,553 2, ,667 4, ,400 2, , ,002 4, ,101 4, ,400 2, , ,503 4,983 * Outside ir ** Filter Mix ox 13

14 4000 MU Horizontal See page 8/9 for coil section dimensions See page 7 for evaporative cooler dimensions See page 10 for energy recovery dimensions LD D E R Y Z K M D/UD G X O K J RD L PLN VIEW FN SETION URNER SETION OIL SETION EVPORTIVE OOLER ENERGY REOVERY SETION FILTER SETION INLET PLENUM OR INLET HOOD H UD N LD/RD O F D ELETRIL ONNETION GS ONNETION RIGHT SIDE VIEW Dimensions Estimated Shipping Weights Width ir Handler Height Length ase Frame Formed hannel ase Frame Structural ngle Filter Section Width Discharge Length Discharge Width Discharge Height Minimum Leg Height Filter Section Length Plenum Width Plenum Length Inlet Hood Length Plenum Height Horizontal Fan Section Horizontal urner Section Filter Section Inlet Hood Inlet Plenum D E F G H J K L M N P R X Y Z , , , , , , ,518 1, , ,808 1, , ,036 2, , ,525 2,361 1, , ,667 4,790 1, , ,101 5,210 1, ,128 14

15 4000 MU Upright F N H K M K J D RD/LD UD FN SETION RD D/UD LD L D ELETRIL ONNETION URNER SETION E GS ONNETION FILTER SETION R O RIN SKIRT (STNDRD FOR OUTDOOR EQUIPMENT) G O LEGS P RIGHT SIDE VIEW FRONT VIEW LEGEND O = Outside ir = ontrol Enclosure D = ottom Discharge LD = Left Discharge RD = Right Discharge UD = Up Discharge = Field Joint (s ) = ccess Door (s 4080 & 4089) = ccess Door (s ) IMPORTNT NOTES: ll dimensions are in inches. ll weights are in pounds. ll dimensions and weights are subject to change without notice. Dimensions apply to both horizontal and upright units. Filters are shipped loose. Legs are shipped loose. ontrol enclosure for 3" or smaller manifolds is 57" H x 57" W x 25" D. ( dimension of 4024 cabinet size is approximately 20" smaller than the control enclosure control enclosure is 57" H x 57" W x 20" D.) To minimize the potential for water entrainment, an inlet hood with moisture limiter or inlet plenum may be desirable. Outdoor air duct size varies. onsult Rapid Engineering LL. ontrol enclosure can be located on left or right side of unit. (Shown on right side in drawings) Estimated Shipping Weights Upright Fan Section , , , , ,341 Upright urner Section ,508 1, ,798 2, ,204 2, ,859 2, ,002 4, ,503 5,044 15

16 4000 FR Horizontal D E J L LD S T X K R M D/UD R P O PLN VIEW K RD R FN SETION URNER SETION INLET HOOD N Z UD x U x U F Q LD/RD D ELETRIL ONNETION R 80% (Optional) ER 80% (Optional) W GS ONNETION RIGHT SIDE VIEW O x W Louver Duct N Outdoor ir Duct Sleeve x W Louver X FILTERS Filtered Inlet Hood Width ir Handler Height Length ase Frame Formed hannel ase Frame Structural ngle Outside ir Length Filter Stand Height Dimensions Discharge Length D E F G H J K L M N P Q R S T U W X Y Z Discharge Width Discharge Length Return ir Width Discharge Height Return ir Length Louver Height Inlet Hood / Duct Height Inlet Hood Length Minimum Leg Height Estimated Shipping Weights Horizontal Fan Section Horizontal urner Section Filter Section Inlet Hood , , , , , ,383 1, ,673 1, ,961 1, ,219 1,994 1, ,667 4,359 1, ,101 4,418 1,

17 4000 FR Upright F Q Z K M K J D RD/LD UD FN SETION RD D/UD LD L D ELETRIL ONNETION 80% R (Optional) S x P 20% O (Optional) URNER SETION 20% O (Optional) G E T GS ONNETION 80% ER (Optional) 20% O (Optional) K M K T H FILTER STND with ULK FILTER MEDI H LEGS Y LEGEND O = Outside ir = ontrol Enclosure D = ottom Discharge LD = Left Discharge RD = Right Discharge UD = Up Discharge R = ottom Return ER = End Return = Field Joint (s ) = ccess Door (s 4080 & 4089) = ccess Door (s ) RIGHT SIDE VIEW FRONT VIEW IMPORTNT NOTES: ll dimensions are in inches. ll weights are in pounds. ll dimensions and weights are subject to change without notice. Dimensions apply to both horizontal and upright units. Filters are shipped loose. Legs are shipped loose. ontrol enclosure for 3" or smaller manifolds is 57" H x 57" W x 25" D. ( dimension of 4024 cabinet size is approximately 20" smaller than the control enclosure control enclosure is 57" H x 57" W x 20" D.) To minimize the potential for water entrainment, an inlet hood with moisture limiter or inlet plenum may be desirable. Outdoor air duct size varies. onsult Rapid Engineering LL. ontrol enclosure can be located on left or right side of unit. (Shown on right side in drawings) Estimated Shipping Weights Upright Fan Section Upright urner Section Filter Stand , , , , , ,373 1, ,663 1, ,129 1, ,553 2, ,002 4, ,503 4,

18 4000 VV Horizontal See page 8/9 for coil section dimensions See page 7 for evaporative cooler dimensions See page 10 for energy recovery dimensions D E N Y Z K M D G X O K J L PLN VIEW FN SETION URNER SETION OIL SETION EVPORTIVE OOLER ENERGY REOVERY SETION FILTER SETION INLET PLENUM OR INLET HOOD O GS ONNETION F ELETRIL ONNETION RIGHT SIDE VIEW D 20% to 100% IR Dimensions Estimated Shipping Weights Width ir Handler Height Length ase Frame Formed hannel ase Frame Structural ngle Filter Section Width Minimum Leg Height Discharge Length Discharge Width Filter Section Length Plenum Width Plenum Length Inlet Hood Length Plenum Height Horizontal Fan Section Horizontal urner Section Filter Section Inlet Hood Inlet Plenum D E F G H J K L M N X Y Z , , , , , ,953 2, , ,333 2, , ,711 2, , ,959 2,842 1, , ,537 5,640 1, , ,971 5,699 1, ,128

19 4000 VV Upright F J K M K D 20% to 100% ir FN SETION L D D ELETRIL ONNETION URNER SETION E GS ONNETION FILTER SETION N O RIN SKIRT (STNDRD FOR OUTDOOR EQUIPMENT) LEGS G O H RIGHT SIDE VIEW FRONT VIEW LEGEND O = Outside ir = ontrol Enclosure D = ottom Discharge = Field Joint (s ) = ccess Door (s 4080 & 4089) = ccess Door (s ) IMPORTNT NOTES: ll dimensions are in inches. ll weights are in pounds. ll dimensions and weights are subject to change without notice. Dimensions apply to both horizontal and upright units. Filters are shipped loose. Legs are shipped loose. s require four legs. s require six legs. ontrol enclosure for 3" or smaller manifolds is 57" H x 57" W x 25" D. ( dimension of 4024 cabinet size is approximately 20" smaller than the control enclosure control enclosure is 57" H x 57" W x 20" D.) To minimize the potential for water entrainment, an inlet hood with moisture limiter or inlet plenum may be desirable. Outdoor air duct size varies. onsult Rapid Engineering LL. ontrol enclosure can be located on left or right side of unit. (Shown on right side in drawings) Estimated Shipping Weights Upright Fan Section , , , , ,870 Upright urner Section ,943 2, ,323 2, ,879 2, ,293 3, ,872 5, ,373 5,833 19

20 One-Way Discharge Head END VIEW RIGHT SIDE VIEW IMPORTNT NOTES: ll dimensions are in inches. ll weights are in pounds. ll dimensions and weights are subject to change without notice. The discharge head has manually adjustable horizontal blades (vertical blades are optional). Discharge head requires field support and mounting by installer. Dimensions 2 (Discharge Inside 2), H and J only applicable to VV units. Dimensions 1 2 D E F G H J Dischage Inside Weight x x x x x x x x x x x x x x x x x x x x x x

21 Three-Way Discharge Head F D (TYPIL) PLN VIEW G E FRONT VIEW SIDE VIEW G IMPORTNT NOTES: ll dimensions are in inches. ll weights are in pounds. ll dimensions and weights are subject to change without notice. The discharge head has manually adjustable horizontal blades (vertical blades are optional). Discharge head requires field support and mounting by installer. Dimensions D E F G Weight

22 Four-Way Discharge Head END VIEW RIGHT SIDE VIEW IMPORTNT NOTES: ll dimensions are in inches. ll weights are in pounds. ll dimensions and weights are subject to change without notice. The discharge head has manually adjustable horizontal blades (vertical blades are optional). Discharge head requires field support and mounting by installer. Dimensions D2 (Inside Dimension of Duct onnections 2), F and G only applicable to VV units. Dimensions D1 D2 E F G Inside Dimensions of Duct Weight onnections x x x x x x x x x x x x x x x x x x x x 116 1, x x 116 1,090 22

23 Discharge Plate RIGHT SIDE VIEW FN SETION D 2 TYPIL D 2 SUPPORT RODS (Y OTHERS) E NTER HOLES ON 4060 THRU ¾ TYPIL 4 ORNERS 13 /16 HOLES DISHRGE PLTE IMPORTNT NOTES: ll dimensions are in inches. ll weights are in pounds. ll dimensions and weights are subject to change without notice. Discharge plate requires field support and mounting by installer. Dimensions D E (min.) E (max.) Weight

24 Legs OLT TWO ORNER LEGS TOGETHER TO MKE N INTERMEDITE NOTE OTTOM PLTE OLTS TO OUTSIDE OF LEG ORNER LEG INTERMEDITE LEG IMPORTNT NOTES: ll dimensions are in inches. ll weights are in pounds. ll dimensions and weights are subject to change without notice. s upright air handlers with 84" or 96" legs, angle bracing is provided. *For models upright air handlers, 24" legs are not available. For models , 24" and 36" legs are not available. Weight (each leg) Leg Height orner Intermediate Orientation Horizontal Upright Style M FR MU VV M Type M FR MU VV VV with Filter Section Filter Section Mixbox 4024 Four orner Legs 4036 Four orner 4040 Four orner Legs & Two N/ 4044 Intermediate Four orner & Two Intermediate Four orner & Four Intermediate Four orner Legs* Six orner Legs VV without Filter Section N/ Six orner legs 24

25 Inlet Hoods FLSHING TPE IR HNDLER INLET Dimensions / IMPORTNT NOTES: ll dimensions are in inches. ll weights are in pounds. ll dimensions and weights are subject to change without notice. Weight 25

26 Service Platform Elect. Enclosure Hand Railing Service Platform Service Platform Support hannel Field Joint (54 Through 89) URNER SETION FRONT VIEW END VIEW IMPORTNT NOTES: ll dimensions are in inches. ll weights are in pounds. ll dimensions and weights are subject to change without notice. The discharge head has manually adjustable horizontal blades (vertical blades are optional). Discharge head requires field support and mounting by installer. Dimensions Weight

27 Dampers NOTE: OTTOM DISHRGE OR UP DISHRGE NOTE: LEFT DISHRGE OR RIGHT DISHRGE (SIDE) NOTE: Discharge damper shown. IMPORTNT NOTES: ll dimensions are in inches. ll weights are in pounds. ll dimensions and weights are subject to change without notice. Damper applicable for MU, M and FR style air handlers. Dimensions Weight D E F G H Side ottom

28 Roof urbs s * D * FN SETION URNER SETION 1 12 TYP E s * * FN & URNER SETION 3 TYP. aulk required for outside perimeter of roof curb at bolted joints. INLET END s 4040 through /2 FLG. Mounting Surface NOTE: End piece is flush with side. Inlet and discharge end panel. Side Panel INLET END 3 FLG. IMPORTNT NOTES: ll dimensions are in inches. ll weights are in pounds. ll dimensions and weights are subject to change without notice. Dimensions E Weight D M/FR/VV MU M/FR/VV MU

29 Roof urb Duct dapter THESE TWO EDGE MUST E INSTLLED FLUSH TO MINTIN THE PROPER OD DIMENSION OF TOP MOUNTING SURFS. * D * MODELS 4073 THRU 4089 ONLY. 19 TYP. MODEL 4089 ONLY DETIL 2 SPLI & ROSS R 20 OLTS, FLT WSHERS, FLNGE NUTS. OPTIONL DUT DPTER SLEEVE DETIL 3 ORNER ONNETION 7 OLTS, FLT WSHERS, FLNGE NUTS TYP. E 3 TYP. INLET END * * ULK REQUIRED FOR OUTSIDE PERIMETER OF ROOF UR T OLTED JOINTS. 19 TYP 1 1/2 FLG. MOUNTING SURF MODELS 4040 THRU 4054 ULK REQUIRED FOR OUTSIDE PERIMETER OF ROOF UR T OLTED JOINTS. INLET END ULK REQUIRED FOR OUTSIDE PERIMETER OF ROOF UR T OLTED JOINTS. SIDE PNEL 3 FLG. NOTE: END PIE IS FLUSH WITH SIDE. INLET ND DISHRGE END PNEL IMPORTNT NOTES: ll dimensions are in inches. ll weights are in pounds. ll dimensions and weights are subject to change without notice. Dimensions shown for fan/burner section only. Roof curb is shipped knocked down. Dimensions E D M/FR/VV MU M/FR/VV MU M/FR/VV Weight MU 29

30 Thank You for Your usiness! This product is not for residential use. This document is intended to assist licensed professionals in the exercise of their professional judgment. Rapid Engineering LL 1100 Seven Mile Road NW omstock Park, MI Telephone: Toll Free: Fax: Rapid Engineering LL ll rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems without written permission of Rapid Engineering LL. Printed in U.S.. RP4DSGN 1216 Rev E

Air Handlers Series. Direct-Fired Heating Pressurization. Dimension and Selection Guide

Air Handlers Series. Direct-Fired Heating Pressurization. Dimension and Selection Guide 2000-Series ir andlers irect-ired eating Pressurization imension and Selection uide 1.800.536.3461 www.rapidengineering.com N: 100% OUTSI IR ONLY 2000-Series Selection uide IMPORTNT NOTS: ll information

More information

Direct-Fired Heating, Ventilation and Pressurization Systems

Direct-Fired Heating, Ventilation and Pressurization Systems 2000-Series irect-ired Heating, Ventilation and Pressurization Systems imension and Selection uide 1.800.536.3461 www.rapidengineering.com N: 100% OUTSI IR ONLY 2000-Series Selection uide NOT: ll information

More information

Direct-Fired Air Handler

Direct-Fired Air Handler irect-fired Air Handler B-Series imension and Selection Guide 1.800.536.3461 www.bananza.com ANSI Z83.4/SA 3.7 100% OUTSI AIR (US & ANAA) Z83.18 - RIRULATION (US) ANSI Z83.25/SA 3.19 PROSS HATR (US & ANAA)

More information

8500-Series Indirect-Fired Heating, Cooling and Pressurization Systems Dimension and Selection Guide 1.800.536.3461 www.rapidengineering.com GAS/OIL HEATING ONLY RAPID 8500-35 through 8500-125 Upright

More information

Direct-Fired Heating, Ventilation and Pressurization Systems

Direct-Fired Heating, Ventilation and Pressurization Systems 2000-Series irect-ired Heating, Ventilation and Pressurization Systems imension and Selection uide 1.800.536.3461 www.rapidengineering.com N: 100% Outside ir Only 2000-Series Selection uide M (m 3 /h)

More information

Dimension and Selection Guide

Dimension and Selection Guide Dimension and Selection Guide GAS/OIL HEATING ONLY IDF-35 through IDF-125 Upright Model Dimensions LD RD LD or RD RA N END VIEW LEGEND BD = Bottom Discharge BD = Bottom Discharge = Top Discharge = Outside

More information

Z % OUTSIDE AIR (US & CANADA) Z RECIRCULATION (US) Z PROCESS HEATER (US AND CANADA)

Z % OUTSIDE AIR (US & CANADA) Z RECIRCULATION (US) Z PROCESS HEATER (US AND CANADA) Z83.4 100% OUTI IR (U & ) Z83.18 - RIRULTIO (U) Z83.25 - RO TR (U ) TT112 & TT115 orizontal Model L L R Y J IR MR URR / LOWR TIO ILTR TIO ILT MR ILT OO WIT IRR M X W I V Z Z T K V Q R R 2 IMIO MOL J K

More information

7500-Series Indirect-ired Air Turnover Units Dimension and Selection Guide 1.800.536.3461 www.rapidengineering.com GAS/OIL EATING ONLY 7500-Series eating Unit DISCARGE PLENU EXTENSIONS (OPTIONAL) J INSPECTION

More information

Air Handling Unit Fan Selection Guide

Air Handling Unit Fan Selection Guide KEES Air Handling Unit Fan Selection Guide This document applies to models: DFG Direct Fired Gas Heater IFG Indirect Fired Gas Heater MUA Tempered Air NTS Non-Tempered Supply Table of Contents: Page 2-4

More information

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH TGDFC-6 DFC Direct Fired Gas Heating System Technical Guide for: Outdoor Mounted Units To 0,000 CFM And 14M BTUH Applied Air Keeps You Warm Featuring the Patented AdaptAire controlled Circulation System

More information

PE-5000 DUCT STATIC PRESSURE SENSING ELEMENT

PE-5000 DUCT STATIC PRESSURE SENSING ELEMENT Technical Data Sheet PE-5000 DUCT STTIC PRESSURE SENSING ELEMENT DESCRIPTION Model PE-5000 units are insertion-type primary duct pressure sensing elements designed to achieve pressure signal accuracy and

More information

MODELS GED/GSD, DFE/DFS, DDE/DDS DIRECT DRIVE SIDEWALL PROPELLER FANS WALL HOUSING MOUNTING OPTIONS WALL HOUSING

MODELS GED/GSD, DFE/DFS, DDE/DDS DIRECT DRIVE SIDEWALL PROPELLER FANS WALL HOUSING MOUNTING OPTIONS WALL HOUSING DIRECT DRIVE SIDEWLL PROPELLER FNS WLL HOUSING MOUNTING OPTIONS WLL HOUSING: This heavy-gauge, all galvanized G-90 steel (aluminum optional) housing provides a simple solution to installing a fan and all

More information

Centrifugal Inline Fans

Centrifugal Inline Fans Centrifugal Inline Fans Models SQ-M and SQ-M Direct and elt Drive UILDING VLUE IN IR. February January 2018 2017 Models SQ-M & SQ-M Centrifugal Square Inline Duct Fans Designed for indoor and outdoor clean

More information

MODELS LCE/LCS, L2E/L2S, L3E/L3S

MODELS LCE/LCS, L2E/L2S, L3E/L3S ELT DRIVE SIDEWLL PROPELLER FNS LINE OVERVIEW Jenco s elt Drive Sidewall Propeller line is designed to exhaust or supply large volumes of air at relatively low static pressures. With 3 levels of construction,

More information

I.C.E. DIRECT FIRED MAKE-UP AIR UNITS

I.C.E. DIRECT FIRED MAKE-UP AIR UNITS INDEX introduction... 2-2 technical data... 2-3 2-5 This section contains product and technical information only. For additional information and product pricing please contact your local ECCO Supply Sales

More information

2- to 5-Ton. Cooling Capacities: 23,600 to 57,000 BTU/h. Packaged Gas/Electric Units. Heating Capacities: 46,000 to 138,000 BTU/h

2- to 5-Ton. Cooling Capacities: 23,600 to 57,000 BTU/h. Packaged Gas/Electric Units. Heating Capacities: 46,000 to 138,000 BTU/h ooling apacities: 23,600 to 57,000 TU/h Heating apacities: 46,000 to 138,000 TU/h GPG13M 2- to 5-Ton Packaged Gas/Electric Units 13 SEE / 80% AFUE ontents Nomenclature... 2... 3 Expanded ooling Data...

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICL GUIDE SPLIT-SYSTEM EVPORTOR LOWERS K*ES120 10 NOMINL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling coil

More information

Installation, Start-Up and Service Instructions

Installation, Start-Up and Service Instructions 62MB,MC,MD,ME040-950 Energy Recovery Ventilators Installation, Start-Up and Service Instructions CONTENTS Page SFETY CONSIDERTIONS...1 INTRODUCTION...1 INSTLLTION... 1-58 Step 1 Inspection...1 Step 2 Install

More information

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h DS ommercial - 5 Ton Packaged Air onditioner 4 SEE / Up to.0 EE ooling apacity: 5,000 58,000 BTU/h ontents Nomenclature... Product Specifications... 4 Expanded ooling Data... 7 Airflow Data... rankercase

More information

D F B. DFBH Rooftop Unit DFBV

D F B. DFBH Rooftop Unit DFBV SYSTEM, UAL LOWER MOEL H Rooftop Unit V ive Sizes H - Horizontal Configuration with ull Curb Cap ase and either Horizontal or Vertical (down) ischarge V - Vertical Configuration with Horizontal ischarge,

More information

U L OIL-FIRED FURNACES. Stellar MBH OUTPUT 80 AFUE DESCRIPTION FEATURES MULTI-POSITION MODELS - P1FM DOWNFLOW/HORIZONTAL MODELS - P1FH

U L OIL-FIRED FURNACES. Stellar MBH OUTPUT 80 AFUE DESCRIPTION FEATURES MULTI-POSITION MODELS - P1FM DOWNFLOW/HORIZONTAL MODELS - P1FH 660.06-TGY (795) MULTI-POSITION S - PFM Stellar 2000 OIL-FIRED FURNES 55-200 MH OUTPUT 80 FUE U L DOWN/HORIZONTL S - PFH DESRIPTION These oil-fired furnaces are compact, decorator-styled warm air heating

More information

Turning Air Into Solutions. AXIFAN VANEAXIAL & TUBEAXIAL FANS TCVS/TCTS TCVSSH/TCTSSH

Turning Air Into Solutions. AXIFAN VANEAXIAL & TUBEAXIAL FANS TCVS/TCTS TCVSSH/TCTSSH Turning ir Into Solutions. XIFN VNEXIL & TUBEXIL FNS TCVS/TCTS TCVSSH/TCTSSH CTLOG X250 May 2012 Vaneaxial&TubeaxialFans Models TCVS I TCTS I TCVSSH I TCTSSH For applications requiring extensive corrosion

More information

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile November 204 BCF Centrifugal Cabinet Contents Standard Construction Features... 3 Options and Accessories... 4 Filter and Mixing Box Data... 5 Typical Installations...

More information

5/8 (16) DIA. MOUNTING HOLES TYP [4] PLACES. SEE NOTE #3 ACCESS PANEL BOTH SIDES 2 1/2 (64) Unit Size Fan Size L W H C D E F G J (508) (406) 25 (635)

5/8 (16) DIA. MOUNTING HOLES TYP [4] PLACES. SEE NOTE #3 ACCESS PANEL BOTH SIDES 2 1/2 (64) Unit Size Fan Size L W H C D E F G J (508) (406) 25 (635) LOER OILS, orizontal and ertical imensional Information TOP N SIE IES (RR 3) LOER OILS 9/ (4) I. MOUNTING OLES TYP [4] PLES. ITOUT SE RIL NOTES:. Provide sufficient clearance to permit access to controls

More information

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz Precision Cooling For Business-Critical Continuity Liebert CW System Design Manual - 26-181kW, 50 & 60Hz TABLE OF CONTENTS LIEBERT CW MODEL NUMBER NOMENCLATURE....................................1 1.0

More information

DP14GM. Packaged Gas / Electric 14 SEER / 81% AFUE 2 to 5 Tons. Cooling Capacity: 23,000 57,500 BTU/h Heating Capacity: 40, ,000 BTU/h

DP14GM. Packaged Gas / Electric 14 SEER / 81% AFUE 2 to 5 Tons. Cooling Capacity: 23,000 57,500 BTU/h Heating Capacity: 40, ,000 BTU/h DP14GM ooling apacity: 23,000 57,500 BTU/h Heating apacity: 40,000 120,000 BTU/h Packaged Gas / Electric 14 SEER / 81% AFUE 2 to 5 Tons ontents Nomenclature... 2 Accessories... 2 Product Specifications...

More information

MODELS GED/GSD, eged/egsd, DFE/DFS, DDE/DDS

MODELS GED/GSD, eged/egsd, DFE/DFS, DDE/DDS LINE OVERVIEW Jenco s Direct Drive Sidewall Propeller line is designed to exhaust or supply large volumes of air at relatively low static pressures. With 3 types of construction, the direct drive models

More information

STR-Series Indirect-Fired Air Turnover Units

STR-Series Indirect-Fired Air Turnover Units STR-Series Indirect-ired Air Turnover Units Dimension and Selection Guide GAS/OIL EATING ONLY STR-Series eating Unit DISCARGE PLENU EXTENSIONS (OPTIONAL) J INSPECTION AND RELIE PORT SPLIT OR SIPENT E CONTROL

More information

FE-1000 INSERTION TYPE AIRFLOW SENSING ELEMENT

FE-1000 INSERTION TYPE AIRFLOW SENSING ELEMENT Technical Data Sheet FE-1000 INSERTION TYPE IR SENSING ELEMENT DESCRIPTION The FE-1000 is an insertion type airflow sensing element designed for quick, easy installation through a small cutout in the existing

More information

DP13CM. Packaged Air Conditioner 3, 4, & 5 Tons / 13 SEER. Cooling Capacity: 36,000-56,000 BTU/h

DP13CM. Packaged Air Conditioner 3, 4, & 5 Tons / 13 SEER. Cooling Capacity: 36,000-56,000 BTU/h DP13M ooling apacity: 36,000-56,000 BTU/h Packaged Air onditioner 3, 4, & 5 Tons / 13 SEER ontents Nomenclature... Product Specifications... 3 Expanded ooling Data... 4 Airflow Data... 10 Heat Kit Electrical

More information

! WARNING: FIRE OR EXPLOSION HAZARD

! WARNING: FIRE OR EXPLOSION HAZARD Form I-SSL/RPL (Version E.3) Obsoletes I-SSL/RPL (Version E.2) INSTALLATION / OPERATION / MAINTENANE Applies to: Model SSL and Model RPL Packaged Systems USTOMER AGENY PRODUT PROESS QS ONVERGENT QUALITY

More information

GCS GCS

GCS GCS ENGINEERING T PKGE GS / ELETRI GS16 024 030 036 048 060 GS20 036 048 060 2 to 5 Ton (7.0 to 17.3 ) FUE 80% SEER up to 12.70 Net apacity 23,200 to 59,000 tuh (6.8 to 17.3 ) Input Heating apacity 50,000

More information

The Industrial Choice. Model PB. Belt Driven. Model PB Direct Drive PRESSURE BLOWER. Model PB

The Industrial Choice. Model PB. Belt Driven. Model PB Direct Drive PRESSURE BLOWER. Model PB The Industrial hoice. Model P elt Driven Model P Direct Drive PRESSURE LOWER Model P ULLETIN 904 March 999 Model P Pressure lowers Pressure blowers provide medium pressure air for cooling, ventilating

More information

GPC13M R-410A, 13 SEER. Packaged Air Conditioner. 3, 4, & 5 Tons. Cooling Capacity: 36,000-56,000 BTU/h

GPC13M R-410A, 13 SEER. Packaged Air Conditioner. 3, 4, & 5 Tons. Cooling Capacity: 36,000-56,000 BTU/h GP13M Packaged Air onditioner R-410A, 13 SEER ooling apacity: 36,000-56,000 BTU/h 3, 4, & 5 Tons Standard Features Energy-efficient compressor with internal relief valve EEM blower motor; PS blower motor

More information

Wall Hoods INSTALLING HOOD CANOPY. Island Hoods

Wall Hoods INSTALLING HOOD CANOPY. Island Hoods HEIGHT OF HOOD The bottom of the hood to should be 30 (76.2 cm) to 36 (91.4 cm) above the countertop. This would typically result in the bottom of the hood being 66 (167.6 cm) to 72 (182.9 cm) above the

More information

Electronic Temperature Control & Bulb Well Assembly (AC)

Electronic Temperature Control & Bulb Well Assembly (AC) Electronic Temperature ontrol & ulb Well ssembly () 0916 86816 This is a line voltage single-stage electronic temperature control with singlepole, double-throw relay output and LED indication. It is designed

More information

DCH Commercial Contents Standard Features Cabinet Features

DCH Commercial Contents Standard Features Cabinet Features DH ommercial 7½ - ½ Ton Packaged Heat Pump Up to. EER &. OP ooling apacity: 90,000 0,000 BTU/h Heating apacity: 90,000,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...8

More information

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS ZEPHYR CABINET Single & Twin Unit Cabinet Fans Moving Your Way TABLE OF CONTENTS Introduction, Certifications & Listings, Features & Benefits 3 Options & Accessories 4 Typical Applications & Belt Drive

More information

CPG Commercial. 7½- to 12½-Ton Self-Contained Packaged 80% AFUE. Cooling Capacity: 90, ,000 BTU/h. Gas/Electric Units. up to 11.

CPG Commercial. 7½- to 12½-Ton Self-Contained Packaged 80% AFUE. Cooling Capacity: 90, ,000 BTU/h. Gas/Electric Units. up to 11. PG ommercial ooling apacity: 90,000 8,000 BTU/h Heating apacity: 68,000 BTU/h Three-Phase 7½- to 2½-Ton Self-ontained Packaged Gas/Electric Units up to.5 EER 80% AFUE Standard Features R-40A chlorine-free

More information

MOUNTING ARRANGEMENT OPTIONS OVERVIEW

MOUNTING ARRANGEMENT OPTIONS OVERVIEW ELT DRIVE SIDEWLL PROPELLER FNS MOUNTING RRNGEMENT OPTIONS OVERVIEW Page Mounting rrangement Description 2-3 Housing Heavy-gauge, all galvanized G-90 steel housing provides a simple solution to installing

More information

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h DS ommercial 3-5 Ton Packaged Air onditioner 4 SEE / Up to.0 EE ooling apacity: 35,000 58,000 BTU/h ontents Nomenclature... Product Specifications... 4 Expanded ooling Data... 7 Airflow Data... 3 rankercase

More information

DSG Commercial. 3-5 Ton Packaged Gas/ Electric Units 14 SEER / up to 12.0 EER Up to 81% Efficient

DSG Commercial. 3-5 Ton Packaged Gas/ Electric Units 14 SEER / up to 12.0 EER Up to 81% Efficient DS ommercial - 5 Ton Packaged as/ Electric Units 4 SEE / up to 2.0 EE Up to 8% Efficient ooling apacity: 5,000 58,000 BTU/h Heating apacity: 46,000 8,000 BTU/H ontents Nomenclature... 2 Product Specifications...

More information

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components AFGP12B Gas/Electric Package Unit Features Shipped for horizontal applications; easily converted to downshot Side-by-side horizontal discharge Standard thermostatic expansion valve Crimp-Tite weld-free

More information

Quantity Model Length (in.) Width (in.) Height (in.) Volume (CFM) SP (in. wg) 1 Air Curtain Supply (ASP)

Quantity Model Length (in.) Width (in.) Height (in.) Volume (CFM) SP (in. wg) 1 Air Curtain Supply (ASP) Mark: ASP 1 Model: ASP - 52.00 - S ASP Air Curtain Supply (ASP) Quantity Model Length (in.) Width (in.) Height (in.) Volume (CFM) SP (in. wg) 1 Air Curtain Supply (ASP) 52 14 10 740 0.13 Supply Collar

More information

DCC Commercial. 3- to 6-Ton Packaged Air Conditioner. Cooling Capacity: 34,600 71,000 BTU/h

DCC Commercial. 3- to 6-Ton Packaged Air Conditioner. Cooling Capacity: 34,600 71,000 BTU/h D ommercial 3- to 6-Ton Packaged Air onditioner 13 SEE / Up to 11.3 EE ooling apacity: 34,600 71,000 BTU/h ontents Nomenclature... Product Specifications... 3 Expanded ooling Data... 7 Airflow Data...

More information

CPH Commercial. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. Cooling / Heating Capacities: up to 11.5 EER up to 3.5 COP. 90, ,000 BTU/h

CPH Commercial. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. Cooling / Heating Capacities: up to 11.5 EER up to 3.5 COP. 90, ,000 BTU/h PH ommercial 7½- to 12½-Ton Self-ontained ooling / Heating apacities: 90,000 118,000 BTU/h Packaged Heat Pump up to 11.5 EE up to 3.5 P Standard Features -410A chlorine-free refrigerant High-efficiency

More information

DCC Commercial. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER. Cooling Capacity: 88, ,000 BTU/h

DCC Commercial. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER. Cooling Capacity: 88, ,000 BTU/h D ommercial 7½ - ½ Ton Packaged Air onditioners Up to. EER ooling apacity: 88,000,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...8 Airflow Data... rankcase Heater...0

More information

Product Data Manual. ERV5000i/e ERV6500i/e ERV8000i/e ERV10000i/e

Product Data Manual. ERV5000i/e ERV6500i/e ERV8000i/e ERV10000i/e Product ata Manual ERV5000i/e ERV6500i/e ERV8000i/e ERV10000i/e Table of Contents Physical ata - Nomenclature Options............................................. 3 Effectiveness Performance ata.................................................

More information

TECHNICAL GUIDE MODELS: MA MODULAR AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: MA MODULAR AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES TEHNIL GUIDE MODELS: MODULR IR HNDLERS FOR USE WITH SPLIT SYSTEM OOLING & HET PUMP 600-2000 FM BLOWERS 2-5 TON OILS OPTIONL 1 & 3φ ELETRI HETERS ISO 9001 ertified Quality Management System Due to continuous

More information

Energy Recovery Laboratory Exhaust

Energy Recovery Laboratory Exhaust Energy Recovery Laboratory Exhaust Model Vektor -ERS For Vektor-M, MH and MS Systems January 2018 Model Vektor -ERS Greenheck s Vektor -ERS is a pre-engineered laboratory exhaust energy recovery system.

More information

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators Version: Dec. 01, 2004 RERV & RERVX Rotary Energy Recovery Ventilators Indoor and Outdoor Installations 250 20,000 CFM Capacities RERVLP Low Profile Indoor Rotary Energy Recovery Ventilators Ideal for

More information

WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1

WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1 WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1 Wallet card photocopy Inspection Authority: Signature: Date: / / Submitted For: ( Owner ) Name Address City _ Prov Postal code Phone ( ) Fax ( ) Designer/Signature:

More information

Model PCD Indirect-Fired, Vertical/Horizontal, Indoor/Outdoor, Packaged, Makeup Air Heating and Air Conditioning System

Model PCD Indirect-Fired, Vertical/Horizontal, Indoor/Outdoor, Packaged, Makeup Air Heating and Air Conditioning System Model P Indirect-Fired, Vertical/Horizontal, Indoor/Outdoor, Packaged, Makeup Heating and onditioning System USTOMR QS NY ONVRNT QULITY SYSTM PROUT PROSS STRT-UP WRRNTY ontents MOLS P, HP SRIPTION... 2

More information

Warm. Air Turnover Systems. Applied Air. Keeps You. Technical Guide for: IFP IFS CAT IFA IFJ TGATS-4. Standard Gas Heat Air Turnover

Warm. Air Turnover Systems. Applied Air. Keeps You. Technical Guide for: IFP IFS CAT IFA IFJ TGATS-4. Standard Gas Heat Air Turnover TGATS-4 Air Turnover Systems Technical Guide for: IFP IFS CAT IFA IFJ Standard Gas Heat Air Turnover Non Gas Heat Slave Unit Standard Cooling Only Air Turnover with Prop Fans Standard Cooling Coil Plus

More information

Spool & Sleeve Valves for ANSI Sub-Bases Series W70

Spool & Sleeve Valves for ANSI Sub-Bases Series W70 Spool & Sleeve Valves for NSI Sub-ases Series W70 5/ Valves Single Direct Solenoid, Spring Return NSI Range of Valve Model vg. Dimensions mm Weight kg 1 G 1/ - W7016331 0.9 177 50 58 1.6.5 - G 1/ W70163331.

More information

GPG13 SINGLE-PHASE, SELF-CONTAINED

GPG13 SINGLE-PHASE, SELF-CONTAINED P1 SINLE-PHASE, SELF-ONTAINED PODUT SPEIFIATIONS 1 SEE/ 80% AFUE 2 5 TON OOLIN APAITIES: 24,000 TO 56,800 TU/H HEATIN APAITIES: 46,000 TO 18,000 TU/H PAKAED AS/ELETI The P1 Packaged as/electric Unit features

More information

PLUG FANS. Space-efficient, plug design. Capacities to 125,000 CFM. Static pressures to 20 WG. Temperatures to 1300 F.

PLUG FANS. Space-efficient, plug design. Capacities to 125,000 CFM. Static pressures to 20 WG. Temperatures to 1300 F. ULLTIN 241 JNURY, 2016 PLUG FNS OUSTFOIL Space-efficient, plug design apacities to 125,000 FM Static pressures to 20 WG Temperatures to 1300 F. PLR TH NW YORK LOWR OMPNY 7660 Quincy Street Willowbrook,

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PPG1GD Series M1010 Product Line Single Packaged Gas/Electric Units 13 SEER 2-5 Ton Units 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY PROMISE The PPG1GD

More information

Air Flow Factors. Alnor Model 6070, 6000, 2220, or 2220-A Probe Orientation

Air Flow Factors. Alnor Model 6070, 6000, 2220, or 2220-A Probe Orientation ir Flow Factors Model: TDC irflow Measurements Procedure 1. Record diffuser velocities with lnor probe in the locations and orientation shown the velocity Measurement Location Chart. Note: Each diagram

More information

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% T.E.

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% T.E. DG ommercial 7½ - ½ Ton Packaged Gas/ Electric Up to. EER / 0% T.E. ooling apacity:,000,000 BTU/h Heating apacity (Output):,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...

More information

CONVERTIBLE SINGLE PACKAGE HEAT PUMP

CONVERTIBLE SINGLE PACKAGE HEAT PUMP PHA D SERIES UNITARY AIRCONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 CONVERTIBLE SINGLE PACKAGE HEAT PUMP FEATURE SINGLE PACKAGE, 2 THRU 5 TON COOLING Single

More information

Packaged Gas/Electric. Cooling Capacity: 23,000 57,500 BTU/h

Packaged Gas/Electric. Cooling Capacity: 23,000 57,500 BTU/h APG4M Packaged Gas/Electric 4 SEER / 8% AFUE ooling apacity:,000 57,500 BTU/h Heating apacity: 40,000 0,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data... 7 Airflow Data...

More information

Inline, Ceiling and Sidewall Exhaust

Inline, Ceiling and Sidewall Exhaust SP, SP 38 Inline, eiling and Sidewall xhaust SP SP UL/cUL 507-33599 - eiling xhaust Fans SP-390 and smaller and SP- are UL/cUL Listed for above bathtub/shower with GFI branch protected circuit. SP- is

More information

DCC Commercial. 15- & 20-Ton, Three-Phase. 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h. Packaged Air Conditioners

DCC Commercial. 15- & 20-Ton, Three-Phase. 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h. Packaged Air Conditioners D ommercial Standard Features R-410A chlorine- free refrigerant High-efficiency scroll compressor opper tube / aluminum fin coils High- and low-pressure switches High-capacity, steel-cased filter drier

More information

BAC, BAF, BAH Central Station Air Handlers

BAC, BAF, BAH Central Station Air Handlers PRODUCT DATA & INSTALLATION Bulletin B80-BA-PDI-5 Part # 1097717 PRODUCT SUPPORT web: b-rp.ca/bah email: ahu@b-rp.ca call: 1-844-893-3222 x527 scan: BAC, BAF, BAH Central Station Air Handlers Indoor and

More information

DCG Commercial. 3- to 6-ton Packaged Gas/Electric Units. Cooling Capacity: 34,600 71,000 BTU/h Heating Capacity: 36, ,400 BTU/h

DCG Commercial. 3- to 6-ton Packaged Gas/Electric Units. Cooling Capacity: 34,600 71,000 BTU/h Heating Capacity: 36, ,400 BTU/h D ommercial - to 6-ton Packaged as/electric Units SEE / up to. EE 80% AFUE ooling apacity: 4,600 7,000 BTU/h Heating apacity: 6,800 0,400 BTU/h ontents Nomenclature... 2 Product Specifications... Expanded

More information

W94. Specifications. Protection: Models Temperature Range Capillary Length Sensing Bulb Valve Body Selection

W94. Specifications. Protection: Models Temperature Range Capillary Length Sensing Bulb Valve Body Selection Temperature Model W91 (No Indicating Dial) W94 (Temperature Indicating Dial) Service Water, Steam, Other Liquids Sizes 1/2 4 onnections Threaded, Union Ends, 125# FLG 250# FLG (optional) ody Material 1/2

More information

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% T.E.

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% T.E. DG ommercial 7½ - ½ Ton Packaged Gas/ Electric Up to. EER / 0% T.E. ooling apacity:,000,000 BTU/h Heating apacity (Output):,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data...

More information

GPC13M COMMERCIAL PRODUCT SPECIFICATIONS 13 SEER PACKAGED AIR CONDITIONER 3- TO 5-TON COOLING CAPACITY 35,000-56,000 BTU/H

GPC13M COMMERCIAL PRODUCT SPECIFICATIONS 13 SEER PACKAGED AIR CONDITIONER 3- TO 5-TON COOLING CAPACITY 35,000-56,000 BTU/H GP13M OMMERIAL PAKAGED AIR ONDITIONER PRODUT SPEIFIATIONS The Goodman GP13M ommercial Packaged Air onditioner features energy-efficient cooling and heating performance in one self-contained unit. This

More information

GPG14M. 2- to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE

GPG14M. 2- to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE ooling apacities:,000 to 57,500 BTU/h Heating apacities: 40,000 to 10,000 BTU/h GPG14M - to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE ontents Nomenclature... Product Specifications... Expanded

More information

DTC Commercial. 3-5 Tons Packaged Air Conditioner Up to 15.5 SEER / Up to 13.0 EER. Cooling Capacity: 35,600 60,000 BTU/h

DTC Commercial. 3-5 Tons Packaged Air Conditioner Up to 15.5 SEER / Up to 13.0 EER. Cooling Capacity: 35,600 60,000 BTU/h DT ommercial 3-5 Tons Packaged Air onditioner Up to 15.5 SEER / Up to 13.0 EER ooling apacity: 35,600 60,000 BTU/h ontents Nomenclature...2 Product Specifications...4 Expanded ooling Data...6 Airflow Data...18

More information

CALL HEIGHT CARD READER TOP OF MONITOR FRONT SIDE CONCRETE SURFACE TO BE FLAT AND LEVEL IN AREA OF UNIT

CALL HEIGHT CARD READER TOP OF MONITOR FRONT SIDE CONCRETE SURFACE TO BE FLAT AND LEVEL IN AREA OF UNIT R OPTEV 5 EXTERIOR SH DISPENSER 5 HIGH ND mm ( ") SFE L009 LL -800-999-600 HEIGHT DEPTH 65 TOP FUNTION KEY 06 (4 ") 8 ( (4 8 ") 89 (5 4 ") (4 8 ") (5 9 8 ") ( 98 8 ") (8 D E RD REDER REEIPT PRINTER DVNED

More information

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile May 2007 BCF Belt Drive Cabinet s Greenheck belt drive low-profile cabinet fans, BCF, are designed for efficiency and reliability in supply, exhaust or

More information

PHB SERIES 7-1/2 and 10 TON

PHB SERIES 7-1/2 and 10 TON PHB SERIES 7-1/2 and 10 TON COMMERCIAL SINGLE PACKAGE HEAT PUMPS COMMERCIAL PACKAGE HEAT PUMP FEATURES Representative photo only, some models may vary in appearance. Rated in accordance with ARI Standard

More information

MPAK Blower Packages. Typical Applications: M-D Pneumatics Open and Enclosed Blower Package

MPAK Blower Packages. Typical Applications: M-D Pneumatics Open and Enclosed Blower Package M-D Pneumatics Open and Enclosed lower Package MPK lower Packages MPK is value-engineered to meet specific applications and designed for simple installation. Open and enclosed blower package configurations

More information

GR4GD Series. Single Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS. GR4GD 13 SEER 2 Ton thru 5 Ton Units FEATURES AND BENEFITS

GR4GD Series. Single Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS. GR4GD 13 SEER 2 Ton thru 5 Ton Units FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS GR4GD Series Single Packaged Gas/Electric Units GR4GD 13 SEER 2 Ton thru 5 Ton Units The GR4GD Series single packaged gas/electrics are high efficiency self contained cooling units

More information

VANEAXIAL & TUBEAXIAL FANS

VANEAXIAL & TUBEAXIAL FANS BULLETIN 482 July 2008 VANEAXIAL & TUBEAXIAL FANS Type "S" Belt Driven Featuring Welded Steel Propellers Models VSBD & TSBD Model TSBD Belt Driven Tubeaxial Type "S" Vaneaxial & Tubeaxial Fans For applications

More information

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE Model: YSHW-DD 00784VIP Introduction YORK DIRECT DRIVE FAN COIL UNITS The YORK Fan Coil Unit is designed for many exposed and concealed applications.

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS 50FN-1SB 50FNX,FNY078,088,104 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE AIR VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE WITH INTEGRAL ECONOMIZER AND HIGH-CAPACITY MODULATING

More information

PHR5. Product Specifications

PHR5. Product Specifications PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R

More information

SUBMITTAL. Palm Beach Gardens Fire Station. Fausto Frias

SUBMITTAL. Palm Beach Gardens Fire Station. Fausto Frias SUBMITTAL Project Palm Beach Gardens Fire Station Date February 5, 2018 Fausto Frias Prepared For TLC Attention- Steve Job Name Palm Beach Gardens Fire Station Mark for AHU-1 Date February 5, 2018 Unit

More information

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems Medium Pressure Axial Fans Model TBI-FS Levels 3, 4 & 5 with Fabricated Steel Propeller Belt Drive Inline or Roof Mounted Upblast Clean Air or Fume Exhaust High Temperature Process Exhaust Emergency Smoke

More information

Fluid Cooling Shell & Tube B / SB Series

Fluid Cooling Shell & Tube B / SB Series Fluid ooling Shell & Tube / S Series 0916 erformance Notes Young Touchstone thermal interchange ompetitively priced 1/4" or 3/8" tubes available Water to water applications Sea water applications, O-Ring,

More information

DTG Commercial. 3-5 Tons Gas/ Electric Units Up to 15.5 SEER and 13.0 EER Up to 81% AFUE

DTG Commercial. 3-5 Tons Gas/ Electric Units Up to 15.5 SEER and 13.0 EER Up to 81% AFUE DT ommercial 5 Tons as/ Electric Units Up to 5.5 SEE and.0 EE Up to 8% AFUE ooling apacity: 5,600 60,000 BTU/h Heating apacity: 6,000 8,000 BTU/h ontents Nomenclature... Product Specifications... Expanded

More information

Product Data Manual. HRV600i HRV700i HRV1200i HRV2000i/e. HRV2000e

Product Data Manual. HRV600i HRV700i HRV1200i HRV2000i/e. HRV2000e Product Data Manual HRV600i HRV700i HRV1200i HRV2000i/e HRV2000e Table of Contents Physical Data - Nomenclature Options............................................. 3 Effectiveness Performance Data.................................................

More information

GR4GA Series Single Packaged Gas/Electric Units

GR4GA Series Single Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS GR4GA Series Single Packaged Gas/Electric Units GR4GA 10 SEER, Three Phase, 208/230V, 460V, 575V 3 Ton thru 5 Ton Units The GR4GA Series single packaged gas/electrics are high

More information

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS These completely assembled units include a well-insulated cabinet, a DX cooling coil

More information

RGMA Series Package Gas Electric SPECIFICATIONS

RGMA Series Package Gas Electric SPECIFICATIONS RGMA Series Package Gas Electric SPECIFICATIONS CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC COMMERCIAL GAS/ELECTRIC UNIT FEATURES EFFICIENCY 7-1/2 thru 20 ton Cooling, 200,000 thru 270,000 BTUH Heating SINGLE

More information

ENGINEERED PRODUCTS. Project: Unit Tag: MS-80-D-3 Page 1 of 5

ENGINEERED PRODUCTS. Project: Unit Tag: MS-80-D-3 Page 1 of 5 ENGINEERED PRODUCTS Model - Unit Type (UT) - MS, Separated Combustion Indoor Unit Capacity (CA) - (50-80) (500-800 mbtu) Furnace Type (FT) - A, B Standard Temperature Rise (30-80)F Indoor Arrangement (IA)

More information

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

Sidewall Propeller Fans Direct Drive. Exhaust / Supply Sidewall Propeller Fans Direct Drive / February 2009 Sidewall Propeller Fans Greenheck s sidewall propeller fan line is the ideal choice for factory and warehouse applications where high volumes of air

More information

Filtered Kitchen Supply Packaged Ventilator

Filtered Kitchen Supply Packaged Ventilator Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................

More information

PCB COMMERCIAL SERIES

PCB COMMERCIAL SERIES PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A WLL-MOUNT -TON IR CONDITIONERS J7 - Right Side Control Panel J7L - Left Side Control Panel, 9.5 EER Hz Solair Wall-Mount ir Conditioner is a self contained energy efficient system, which is designed to

More information

MIS SERIES. Mist Eliminator. Installed differential pressure gauge and optional zero air-loss drain valve. Air or Water Cooled Aftercooler

MIS SERIES. Mist Eliminator. Installed differential pressure gauge and optional zero air-loss drain valve. Air or Water Cooled Aftercooler MIS SERIES Mist Eliminator The ircel MIS Mist Eliminator (300-8000 scfm) provides a full line of mist eliminators to effectively remove oil, solids and water from your compressed air system. In addition,

More information

DCH Commercial. 3- to 6-Ton, Three-Phase Packaged Heat Pumps. Cooling Capacity: 35,000 70,000 BTU/h Heating Capacity: 34,600 70,000 BTU/h

DCH Commercial. 3- to 6-Ton, Three-Phase Packaged Heat Pumps. Cooling Capacity: 35,000 70,000 BTU/h Heating Capacity: 34,600 70,000 BTU/h DH ommercial Standard Features -4A chlorine-free refrigerant High-efficiency scroll compressor opper tube / aluminum fin coils High- and low-pressure switches efrigerant accumulator ontactor with lugs

More information

Direct Gas-Fired Indoor and Outdoor Heating and Make-Up Air Units

Direct Gas-Fired Indoor and Outdoor Heating and Make-Up Air Units 7-50. September, 009 Direct Gas-Fired Indoor and Outdoor Heating and Make-Up ir Units HORIZONTL CONFIGURTION VERTICL CONFIGURTION Table of Contents Direct-fired make-up units are designed to provide an

More information

Horizontal and Vertical Belt Drive Blower Coil Units (Models AHI and AVI)

Horizontal and Vertical Belt Drive Blower Coil Units (Models AHI and AVI) Technical Bulletin Issue Date December 6, 2004 Horizontal and Vertical Belt Drive Blower Coil Units (Models AHI and AVI) Model AHI Horizontal and Model AVI Vertical Belt Drive Blower Coils are designed

More information

GPH13H. Packaged Heat Pump. 13 SEER / R-410A 2 to 5 Tons. Cooling Capacity: 24,000-57,500 BTU/h Heating Capacity: 22,000-54,500 BTU/h

GPH13H. Packaged Heat Pump. 13 SEER / R-410A 2 to 5 Tons. Cooling Capacity: 24,000-57,500 BTU/h Heating Capacity: 22,000-54,500 BTU/h H Packaged Heat Pump ooling apacity: 24,000-57,500 BTU/h Heating apacity: 22,000-54,500 BTU/h 13 SEER / R-410A 2 to 5 Tons Standard Features Energy-efficient compressor with internal relief valve PS blower

More information

TECHNICAL MANUAL *PG13 R410A

TECHNICAL MANUAL *PG13 R410A TECHNICAL MANUAL AL *PG13 R410A Single Phase Package Gas Units Refer to Service Manual RS6300007 for installation, operation, and troubleshooting information. All safety information must be followed as

More information

Ceiling and Inline Fans

Ceiling and Inline Fans Ceiling and Inline Fans Page Introduction.....................................2 Construction Features..............................3 Specifications and Dimension Data GC 122-184....................................4

More information