I.C.E. DIRECT FIRED MAKE-UP AIR UNITS
|
|
- Samson Horn
- 6 years ago
- Views:
Transcription
1 INDEX introduction technical data This section contains product and technical information only. For additional information and product pricing please contact your local ECCO Supply Sales Branch. ECCO is proud to be a member of: ASHRAE American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. HRAI Heating, Refrigeration and Air Conditioning Institute of Canada HARDI Heating, Airconditioning & Refrigeration Distributors International SMACNA Sheet Metal and Air Conditioning Contractors National Association SPIDA Spiral Duct Manufacturers Association CIPH Canadian Institute of Plumbing & Heating ECCO Supply 2-1
2 introduction Direct-fired units are considered 100% efficient, thus they offer the lowest operating cost solution for heating and ventilating applications. With no heat exchanger, 100% of the energy is transferred to the air stream, instead of up to 30% of the energy lost through flue or piping losses, as is the case for indirect fired units or boilers for glycol systems. Due to the simplicity of the direct-fired unit, the BMA series also offers the lowest capital investment over an indirect-fired unit or a glycol system. C Benefits Ensures your exhaust systems capacity performs correctly Eliminates cold building perimeters due to high infiltration Eliminates drafts at exterior doors Eliminates doors from being hard to open from the outside Reduces uneven temperature conditions in the building space Eliminates gravity vented gas appliances from back venting Applications Factory ventilation Kitchen ventilation Body shop ventilation Mechanics garage ventilation Welding shop ventilation And so many more applications! Advantages Fully customizable, available with almost any type of material, in any gauge Wide variety of configurations available Extensive control options, from basic discharge air control, to continuously monitored PLC systems Excellent turnaround time ICE offers some of the best turnaround times in the industry High value ICE engineers value into each unit through our hands-on engineering team, to ensure your equipment is specifically suited for your application Basic Features High quality precision built equipment High turndown (up to 30:1) stainless steel burners Consistent, thoroughly factory tested equipment Latest in control valve technology to ensure long term consistent performance Completely safe operation through solid state flame monitoring and high temperature limits Excellent access and serviceability to keep maintenance costs minimized ETL and C-ETL listed, conforms to ANSI Z83.4B-2002 and CSA 3.7B-2002, ANSI Z83.18a-2001 Maximum of 120 F temperature rise and 120 F discharge temperature Options Available Louvered inlet sections Mixbox for 80/20 applications (US applications only) Cooling coil sections, and packaged DX cooling 4-way and horizontal discharge heads Evaporative cooling FM/IRI manifolds Service platforms Variable air volume And so much more! I.C.E. is a skilled manufacturer of Gas fire direct and indirect make-up air units Packaged cooling equipment Custom integrated heat recovery units Specializing in commercial and industrial retrofits Configurations Horizontal Right Hand Horizontal Left Hand Vertical Upflow Vertical Downflow 2-2
3 technical data performance specifications Applicable to natural and propane fired units DESIGN MODEL BLOWER DISCHARGE **EXTERNAL STATIC PRESSURE TEMPERATURE RISE GAS AIR FLOW NUMBER SIZE VELOCITY (BURNER AND BLOWER ALREADY INCLUDED) CONNECTION CFM INCHES FPM BRAKE HORSEPOWER MBH CAPACITY INCHES 0.25"WC 0.50"WC 0.75"WC 1.00"WC 1.50"WC 2.00"WC 60DegF 70DegF 80DegF 90DegF 100DegF 110DegF 120DegF 1600 BMA * 0.97* 1.17* 1.38* BMA * 1.37* 1.59* / BMA * 1.87* BMA / BMA BMA BMA * 1.49* 1.67* 2.04* 2.44* BMA BMA * 2.07* 2.46* 2.87* BMA BMA * 3.42* BMA * BMA * 2.19* 2.69* 3.73* BMA BMA * 3.66* BMA BMA * 4.16* BMA BMA * BMA * 2.72* 3.06* 3.76* 4.58* BMA BMA BMA * 3.45* 4.20* 4.97* BMA BMA BMA * 3.87* 4.66* 5.48* BMA BMA * 6.61* BMA * 5.39* 6.24* BMA BMA * BMA * 7.50* / BMA BMA BMA * BMA * 5.05* 6.09* 8.91* BMA BMA / BMA BMA * 9.29* BMA BMA BMA * 11.35* BMA BMA * BMA BMA BMA BMA BMA BMA * BMA BMA *Indicated that smaller blower(s) is/are required to achieve the brake horsepower listed. **Add for accessory static pressure drops as required
4 technical data (cont d) performance specifications (cont d) Applicable to natural and propane fired units DESIGN MODEL BLOWER DISCHARGE **EXTERNAL STATIC PRESSURE TEMPERATURE RISE GAS AIR FLOW NUMBER SIZE VELOCITY (BURNER AND BLOWER ALREADY INCLUDED) CONNECTION CFM INCHES FPM BRAKE HORSEPOWER MBH CAPACITY INCHES 0.25"WC 0.50"WC 0.75"WC 1.00"WC 1.50"WC 2.00"WC 60DegF 70DegF 80DegF 90DegF 100DegF 110DegF 120DegF BMA BMA BMA BMA * BMA BMA BMA BMA BMA BMA BMA * BMA BMA BMA BMA * / BMA * BMA * 14.48* 17.88* 25.23* BMA BMA BMA BMA * BMA * 16.02* 19.51* 23.24* BMA BMA BMA BMA BMA * 26.11* BMA BMA BMA BMA * BMA BMA BMA BMA BMA BMA BMA BMA BMA THIS BMA * AREA BMA MUST BMA BE BMA PSI BMA IN COMING BMA PRESSURE BMA BMA BMA BMA BMA *Indicated that smaller blower(s) is/are required to achieve the brake horsepower listed. **Add for accessory static pressure drops as required. (cont d on next page) 2-4
5 technical data (cont d) performance specifications (cont d) NOTEs: The air volume capacities are based on a 75 room temperature at sea level. The input capacities were based on: MBH = (CFM C (LAT - EAT)/1000 MBH BTUH/1000 CFM Maximum air capacity (cubic feet/minute) C 1,188 based on an air density at 75 F EAT Entering Dry Bulb Temperature ( F) LAT Leaving Dry Bulb Temperature ( F) Brake horsepower data is based on forward curved DWDI fans and includes drive losses. Consult your local ECCO Supply Sales Representative for: Higher air capacities or special applications Performance data at higher static pressures than listed Performance data at elevations other than sea level 2-5
MINIVEIL AIR CURTAINS
INDEX INTRODUCTION BENEFITS... 12-2 HOW TO SELECT AN AIR CURTAIN... 12-2 INDUSTRIAL AIR CURTAIN SYSTEMS CFA... 12-3 12-4 CFC... 12-5 12-6 EWD... 12-6 12-7 This section contains product and technical information
More informationOIL BURNER NOZZLES
INDEX Accessories... 14-6 14-8, 14-10 DELAVAN Available Nozzle Sizes... 14-5... 14-2 Hago OIL BURNER Nozzles B Solid Cone Black Caps... 14-3 DFN Dual Filtration White Caps... 14-4 EH Extra Hollow Cone
More informationECCODUCT. In-Slab Duct Ventilation System ECCO is proud to be a member of: REV. W-4
MANUFACTURING EXCELLENCE HVAC Steel Duct Pipe & Fittings ECCODUCT In-Slab Duct Ventilation System www.eccoduct.com ECCO is proud to be a member of: SMACNA Sheet Metal and Air Conditioning Contractors National
More informationTHERMOSCREENS AIR CURTAINS
INDEX c-range recessed... 12-4 surface mounted... 12-4 introduction... 12-2 Jet range... 12-6 -range recessed... 12-5 surface mounted... 12-5 selection guide... 12-3 technical data... 12-7 12-11 This section
More informationAir Handling Unit Fan Selection Guide
KEES Air Handling Unit Fan Selection Guide This document applies to models: DFG Direct Fired Gas Heater IFG Indirect Fired Gas Heater MUA Tempered Air NTS Non-Tempered Supply Table of Contents: Page 2-4
More informationWFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design
80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.
More informationProduct Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE
COMFORT 95 DIRECT OR NON---DIRECT VENT 4 --- WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct
More informationWORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1
WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1 Wallet card photocopy Inspection Authority: Signature: Date: / / Submitted For: ( Owner ) Name Address City _ Prov Postal code Phone ( ) Fax ( ) Designer/Signature:
More informationWFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design
80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.
More informationWarm. Air Turnover Systems. Applied Air. Keeps You. Technical Guide for: IFP IFS CAT IFA IFJ TGATS-4. Standard Gas Heat Air Turnover
TGATS-4 Air Turnover Systems Technical Guide for: IFP IFS CAT IFA IFJ Standard Gas Heat Air Turnover Non Gas Heat Slave Unit Standard Cooling Only Air Turnover with Prop Fans Standard Cooling Coil Plus
More informationISO 9001 REGISTERED HTDM SERIES HTDM0600BR
ISO 9001 REGISTERED HTDM SERIES C R R HTDM0600BR TABLE OF CONTENTS Page 1. Standard and Optional Features 2. Efficiencies and Weight Specifications 3. Amperage Specifications & Static Pressure Losses Due
More informationTECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES
TECHNICAL GUIDE Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated
More informationUpflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace
Product Data Upflow/ Horizontal Left/Right, Downflow Two Condensing Gas Fired Furnace Upflow, Convertible to HorizontalRight or HorizontalLeft S9V2B040U3PSBB S9V2B060U3PSBB S9V2B060U4PSBB S9V2B080U3PSBB
More informationTECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES
TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated
More informationPRIMEX. Venting Products and Accessories. ECCO is proud to be a member of: REV. W-4b
MANUFACTURING EXCELLENCE HVAC Steel Duct Pipe & Fittings PRIMEX Venting Products and Accessories ECCO is proud to be a member of: SMACNA Sheet Metal and Air Conditioning Contractors National Association
More informationOperating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16
SOUND REFRIGERANT ENVIRONMENTALLY Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE GAS / ELECTRIC, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT
More informationCooling Capacity CFM in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
More informationG8MVL. Product Specifications
80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Supports two stage cooling units Flame roll out sensors standard Category I venting Blocked vent switch Dehumidification feature in
More information500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)
500-YH SINGLE DUCT AIR TERMINAL UNIT FORM 130.12-EG1 (1101) Table of Contents General Description.......................................................................3 500-YH Features........................................................................4-5
More informationKG7T (E and N Series)
TECHNICAL SPECIFICATIONS KG7T (E and N Series) Two Stage, Fixed Speed ECM, Condensing Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency upflow gas
More informationTECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.
TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES 40-130 MBH INPUT HIGH-EFFICIENCY INDUCED COMBUSTION EFFICIENCY RATING CERTIFIED This product was manufactured in a plant whose
More informationMODEL IFG INDIRECT FIRED MAKE-UP AIR HEATER
L (Housing Arr. H) 4" 6" A=Blower B=Filter C=Intake Downturn Plenum W Intake damper (Optional) H Birdscreen " Curb Cap D Electrical connection H Housing V-bank filters intake hood Gas connection E Lifting
More informationFG7T (E and N Series)
TECHNICAL SPECIFICATIONS FG7T (E and N Series), Smartlite Two Stage, Fixed Speed ECM, High Efficiency Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency
More informationWarm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH
TGDFC-6 DFC Direct Fired Gas Heating System Technical Guide for: Outdoor Mounted Units To 0,000 CFM And 14M BTUH Applied Air Keeps You Warm Featuring the Patented AdaptAire controlled Circulation System
More informationProduct Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm
Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of
More informationTECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY
TECHNICAL SPECIFICATIONS KG7S (C and L Series) High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92. AFUE Input 38,000-20,000 Btuh
More informationDirect Gas-Fired Make-up Air Heaters
Direct Gas-Fired Make-up Air Heaters SDM-E SERIES OUTDOOR SPECIFICATIONS MANUAL MANUFACTURED BY : BROTHERS LIMITED TABLE OF CONTENTS Summary description of the unit...4 Required burner capacity...6 Dimensions
More information500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)
500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT Table of Contents Introduction...3 500-YVI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor Amperage
More informationTECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303)
TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN 40-130 MBH INPUT HIGH-EFFICIENCY INDUCED COMBUSTION DESCRIPTION These high efficiency, dedicated downflow compact units employ induced
More informationAF90. AF90 Gas Furnace High Efficiency. Features
AF90 AF90 Gas Furnace High Efficiency Features Up to 92.1% AFUE Heating size range 50,000 125,000 BTUH 1-1/2 5 tons cooling capacity supported Twenty-year limited warranty on heat exchanger Five-year warranty
More informationFG7S (C and L Series)
TECHNICAL SPECIFICATIONS FG7S (C and L Series) High Efficiency/Direct Vent or Non Direct Vent Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92.1 AFUE Input 38,000-120,000
More informationVG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input
TECHNICAL SPECIFICATIONS VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38,000-120,000 Btuh Input The high efficiency upflow
More informationR6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY
TECHNICAL SPECIFICATIONS R6GP Series 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A 11.2 EER Commercial System These units are designed specifically for retrofit applications and compatibility
More informationICEMINI & Vertical MTI Units
ICEMINI & Vertical MTI Units ICEMINI Units......K-1 ICEMINI-8MPN (Dimension Information)....... K-2 ICEMINI-8MPN (Horizontal Small)....... K-3 ICEMINI-8MPN (Vertical Small)........ K-4 ICEMINI-8MPN (Vertical
More informationTECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.
036-21047-001 Rev. A (4/00) DESCRIPTION These high efficiency, compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units
More informationKG7T (C and L Series)
TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency
More informationPrecision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz
Precision Cooling For Business-Critical Continuity Liebert CW System Design Manual - 26-181kW, 50 & 60Hz TABLE OF CONTENTS LIEBERT CW MODEL NUMBER NOMENCLATURE....................................1 1.0
More informationTable of Contents GF801U Series
FORM NO. GSC-520 GF801U SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES The Sure Comfort line of upflow/horizontal gas furnaces are designed
More information500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)
500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT Table of Contents General Information...3 500-YCI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor
More informationPRICED BILL OF QUANTITIES Package : Air conditionning. Manhours (h) Unit (tariff) Discount Total Unit. Total. Material cost
Spend study of price carries out by Margins ratios (rate on selling price) Mark up (coef. on cost price) - Overheads 15,00% Mark up (N1) 1,25 - Profits 2,00% - Mark up N 1 1,20 1 - Consulting firm fees
More informationProduct Data. that this product meets the S 95% AFUE S Two -stage operation
DIRECT VENT 4 -WAY MULTIPOISE CONDENSING GAS FURNACE 95% DOWNFLOW / HORIZONTAL ORIENTATIONS 93.5% UPFLOW ORIENTATION 95% Variable Speed Two -Stage Heating Furnace FLEXIBILITY S Supports two -stage cooling
More informationGas-Fired Separated Combustion Unit Heaters Propeller & Blower Models
6-75. September, 2008 Gas-Fired Separated Combustion Unit Heaters Propeller & Blower Models MODEL HDS MODEL HDC MODEL PTS (shown) / BTS 6-75. TABLE OF CONTENTS Modine s separated combustion unit heaters
More informationUpflow, Upflow / Horizontal, Counterflow / Horizontal
Upflow, Upflow / Horizontal, Counterflow / Horizontal CG80 Features and Benefits HEAT EXCHANGER DESIGN Aluminized steel tapered S-curve design primary exchanger with crimped no weld construction for long
More informationUPFLOW/ HORIZONTAL GAS FURNACE
FORM NO. GFJ-542 UPFLOW/ HORIZONTAL GAS FURNACE Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark Ignition for reliability and longevity
More information80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES
FORM NO. G66-478 REV. 5 Supersedes Form No. G66-478 Rev. 4 80PJ SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80 PLUS A.F.U.E. UPF/HORIZONTAL GAS FURNACES Features The WeatherKing
More informationKG7T (C and L Series)
TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency
More information95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES
95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES FORM NO. 95G2E-100 (04/2016) CONTROLS Two stage gas valve Integrated ignition and fan control Control board retains last ten (10)
More informationDimension and Selection Guide
Dimension and Selection Guide GAS/OIL HEATING ONLY IDF-35 through IDF-125 Upright Model Dimensions LD RD LD or RD RA N END VIEW LEGEND BD = Bottom Discharge BD = Bottom Discharge = Top Discharge = Outside
More information80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES
FORM NO. G66-495 Supersedes Form No. P66-765 Rev. 3 80PS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80% A.F.U.E. UPF/ HORIZONTAL GAS FURNACES The WeatherKing line of upflow/horizontal
More informationTGIF-3. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.
TGIF-3 Indirect Fired Heating Systems Technical Guide for: IF Indoor Installations IFW Outdoor Installations Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide In the business of
More informationInstallation, Operation and Maintenance Manual
Document 481038 Model PVF(-H) and PVG Indirect Gas-Fired Heat Modules Indirect Gas-Fired Furnaces Installation, Operation and Maintenance Manual Please read and save these instructions for future reference.
More informationProduct Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat
PG8MVA PG8JVA 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE INPUT CAPACITIES: 70,000 thru 135,000 Btuh SERIES A Product Data multipoise design, through -the-furnace downflow venting, 13 different
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model DF6SF Series M120 Product Line ihybrid Package Units Up to 15 SEER 2-5 Ton Units 4-Stage Heat/2-Stage Cool with Variable Speed Blower 2 12 YEAR ALL PARTS WARRANTY This product
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model DF6SE Series M120 Product Line ihybrid Package Units Up to 14 SEER 2-5 Ton Units 4-Stage Heat/2-Stage Cool with Variable Speed Blower 2 12 YEAR ALL PARTS WARRANTY This
More informationGR4GA Series Single Packaged Gas/Electric Units
TECHNICAL SPECIFICATIONS GR4GA Series Single Packaged Gas/Electric Units GR4GA 10 SEER, Three Phase, 208/230V, 460V, 575V 3 Ton thru 5 Ton Units The GR4GA Series single packaged gas/electrics are high
More informationVENTING & COMBUSTION AIR GUIDE
PRE-INSTALLATION APPLICATION GUIDE VENTING & COMBUSTION AIR GUIDE Natural Gas, Propane and Dual Fuel Modulating and Condensing BOILER BODY VENT STARTER SECTION APPLIES TO MODELS: BMK 750 BMK 1000 BMK 1500
More informationGUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS GUH 95 Series Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency upflow gas
More informationSolutions from SPTT-3
Solutions from SPTT-3 System Principle Of Operation Sdhv 21 60000 BTU 9 9 2000 BTU 10 2 Conventional D/T/R Diffusion, Throw & Return. Air change. Works for heating OR cooling, NOT BOTH. Aspiration Static
More informationRheem Classic Series Upflow/Horizontal Gas Furnace
Gas Furnaces Rheem Classic Series Upflow/Horizontal Gas Furnace R801P- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance
More information80% A.F.U.E. DOWNFLOW GAS FURNACES
FORM NO. G66-496 REV. 5 Supersedes Form No. G66-496 Rev. 4 RGLS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) 80% A.F.U.E. DOWNF GAS FURNACES The
More informationHVAC INDOOR MAKE-UP AIR HANDLERS
GIAC-8 HVAC INDOOR MAKE-UP AIR HANDLERS Application Manual PACKAGED INDOOR ARRANGEMENTS FOR MAKE-UP AIR, HEATING AND COOLING Contents 2 PAGE GENERAL INFORMATION 2, 3 MODEL NUMBER DESCRIPTION 4 INDOOR DUCT
More informationInstallation, Operation and Maintenance Manual
Document 481038 Model PVF and PVG Indirect Gas-Fired Heat Modules Indirect Gas-Fired Furnaces Installation, Operation and Maintenance Manual Please read and save these instructions for future reference.
More information8500-Series Indirect-Fired Heating, Cooling and Pressurization Systems Dimension and Selection Guide 1.800.536.3461 www.rapidengineering.com GAS/OIL HEATING ONLY RAPID 8500-35 through 8500-125 Upright
More informationCooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)
80% Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out senss standard Categy I venting Blocked vent switch Louvered do 24 VAC and 115 VAC humidifier terminal Electronic air cleaner terminal
More informationW801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )
FORM NO. G66-549 REV. 3 Supersedes Form No. G66-536 Rev. 3 DOWNFLOW GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct Spark Ignition System for reliability and
More informationRheem Classic Series Upflow/Horizontal Gas Furnace
THIS MODEL Air Gas Furnaces Rheem Classic Series Upflow/Horizontal Gas Furnace R801S- (Upflow/Horizontal) Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE
More informationTECHNICAL GUIDE MODELS: P4DN 80 AFUE DOWNFLOW GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.
036-21053-001 Rev. A (4/00) DESCRIPTION These high efficiency, dedicated downflow compact units employ induced combustion, reliable hot surface ignition and high heat transfer tubular heat exchangers.
More informationTECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION
Heating TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE NATURAL GAS 58-188 MBH OUTPUT Air Conditioning R DESCRIPTION This
More informationEasily removable slide-out blower design PSC multi-speed permanently lubricated blower motor for low maintenance and optimum efficiency
Gas Furnaces PRODUCT SPECIFICATIONS INSTALLATION OPTIONS A vailable in Upflow/Horizontal and Counterflow models 80% AFUE 44,000 to 32,000 Btuh Input.5 to 5 Tons Add-On Cooling HEAT EXCHANGER A luminized
More informationRheem Value Series Downflow Gas Furnace
THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Value Series Downflow Gas Furnace RGLS- Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE MID A.F.U.E.
More informationTECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION
Heating TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE NATURAL GAS 58-188 MBH OUTPUT Air Conditioning R DESCRIPTION This
More informationGMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE
/ 95%/93% AFUE MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE HEATING INPUT: 46,000 115,000 BTU/H LIFETIME HEAT EXCHANGER LIMITED WARRANTY 10 YEAR HEAT REPLACEMENT CXCHANGER WARRANTY
More informationHVAC RELATED PRODUCTS
MANUFACTURING EXCELLENCE HVAC Steel Duct Pipe & Fittings HVAC RELATED PRODUCTS ECCO is proud to be a member of: SMACNA Sheet Metal and Air Conditioning Contractors National Association www.smacna.org HRAI
More informationGR4GC Series Single Packaged Gas/Electric Units
TECHNICAL SPECIFICATIONS GR4GC Series Single Packaged Gas/Electric Units GR4GC 12 SEER, Three Phase 3 Ton thru 5 Ton Units The GR4GC Series single packaged gas/electrics are high efficiency self contained
More informationCooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)
80% Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out senss standard Categy I venting Blocked vent switch Louvered do 24 VAC and 115 VAC humidifier terminal Electronic air cleaner terminal
More informationGAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES
FORM NO. G11-485 REV. 5 Supersedes Form No. G11-485 Rev. 4 GAS FURNACES RGPN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) ISO 9001:2000 Annual Fuel
More informationRheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace
THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace RGPT- Series 80% A.F.U.E. Input Rates 50-125 kbtu ENER UIDE Annual Fuel Utilization Efficiency
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model DF6SF Series Rev A M120 Product Line ihybrid Dual Fuel Package Units 15 SEER 2-5 Ton Units 2-Stage Heat/2-Stage Cool with Variable Speed Blower 2 12 YEAR ALL PARTS WARRANTY
More informationPGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No
PGMD Series 10 SEER PACKAGE COOLING 1-1/2THRU5TONSINGLEPHASE CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Efficiency: PGAA - 10 SEER. Combination gas heating and electric cooling, self-contained
More informationA95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS
Two- Variable Speed HEAT EXCHANGER DESIGN 409 Stainless steel primary heat exchanger material AL29-4C Stainless steel secondary heat exchanger Non-welded crimped S-curve primary heat exchanger design for
More informationGAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES
FORM NO. G11-487 REV. 1 Supersedes Form No. G11-487 Rev. 8 GAS FURNACES RGLN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization
More informationInstallation, Start-Up and Service Instructions
Installation, Start-Up and Service Instructions 48AJ,AK,AW,AY020-060 with Reciprocating Compressor 48EJ,EK,EW,EY024-068 Single Package Rooftop Units Electric Cooling/Gas Heating CONTENTS Page SAFETY CONSIDERATIONS......................
More informationOIL FIRED UPFLOW FURNACE SPECIFICATIONS VHF-ABP (BECKETT AFG)
MODEL NO. OIL FIRED UPFLOW FURNACE SPECIFICATIONS VHF-ABP (BECKETT AFG) VHF-ANP / VHF-ANE (BECKETT NX) HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250
More informationW801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )
FORM NO. G66-547 REV. 4 Supersedes Form No. G66-536 Rev. 3 DOWNF GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct spark ignition for reliability and longevity
More informationDF6SF Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 4-Stage Heat/2-Stage Cool with Variable Speed Blower ihybrid Package Units with R-410A
TECHNICAL SPECIFICATIONS DF6SF Series 4-Stage Heat/2-Stage Cool with Variable Speed Blower ihybrid Package Units with R-410A DF6SF up to 15 SEER 2 Ton thru 5 Ton Units These dual fuel package units are
More informationKG7S (A and K Series)
TECHNICAL SPECIFICATIONS KG7S (A and K Series) High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80+ AFUE Input 45,000-126,000 Btuh The high efficiency gas furnace may be installed
More informationProduct Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons
Product Data Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 1 Nominal Tons The 50XCA single-package cooling units with integral air-cooled condensers
More informationElectric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System
V-Series (rev. 08/17/10) Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System Note: Optional items and/or items requiring a choice, are shown between brackets and/or parentheses
More informationGPG15 Series 80% AFUE. Single-Phase, Self-Contained. up to 15 SEER. Cooling Capacity: 23,200 56,500 BTU/h. Heating Capacity: 69, ,000 BTU/h
GPG15 Series Single-Phase, Self-Contained Cooling Capacity: 23,200 56,500 BTU/h Heating Capacity: 69,000 138,000 BTU/h Standard Features High-efficiency compressor Durable, corrosion-resistant T-140 aluminized
More informationGF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)
FORM NO. GSC-515 GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) TWO STAGE DOWNFLOW GAS FURNACES The Sure Comfort 2-Stage line of downflow gas furnaces
More informationPRE-INSTALLATION VENTING AND COMBUSTION AIR DESIGN GUIDE
Benchmark Series GF-2050 PRE-INSTALLATION VENTING AND COMBUSTION AIR DESIGN GUIDE Natural Gas, Propane Gas, or Dual Fuel Fired Modulating, Condensing BENCHMARK & Benchmark Platinum Gas-Fired This document
More informationFANTECH
index AIR CURTAINS AS/AC Series... 12-8 Axial fans fade Series... 12-4 12-5 CONTROLS AND SWITCHES... 12-13 12-14 DAMPERS BACKDRAFT... 12-15 IRIS... 12-15 DUct Fans fg series inline round centrifugal (replaces
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PDF2SF Series M1200 Product Line ihybrid Package Units Up to 15 SEER 2-5 Ton Units 4-Stage Heat/2-Stage Cool with Variable Speed Blower 2 M1200-12 YEAR ALL PARTS LIMITED
More informationRheem Value Series Upflow/Horizontal Gas Furnace
THIS MODEL Gas Furnaces Rheem Value Series Upflow/Horizontal Gas Furnace RGPS- Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE 80.0% MID HIGH 78% 82% 88%
More informationQ4SE Series Single Packaged Heat Pump, Single Phase
TM TECHNICAL SPECIFICATIONS Q4SE Series Single Packaged Heat Pump, Single Phase Q4SE-14 SEER 2-5 Ton Units Cooling: 23,600 to 56,500 Btuh Heating: 22,200 to 55,500 Btuh The Q4SE Series single packaged
More informationCAT PAU 99(2) SUPERSEDES CAT.NO SARAVEL PACKAGED AIR CONDITIONING UNITS
CAT PAU 99(2) SUPERSEDES CAT.NO.200-95 SARAVEL PACKAGED AIR CONDITIONING UNITS TABLE OF CONTENTS Introduction...3 Physical Data..... 4 Selection Procedure....5-7 Water Cooled Packaged Unit Ratings....
More informationWFMR/WFML. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design
80% AFUE GAS FURNACE Multipoise Design Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. F verification of certification f individual products, go to www.ahridirecty.g.
More informationRheem Classic Series Downflow Gas Furnace
Gas Furnaces Rheem Classic Series Downflow Gas Furnace R801S (Downflow) Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department
More informationFORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1
FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 TZ80MSS (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential
More informationRheem Classic Plus Series Downflow Gas Furnace
Gas Furnaces Rheem Classic Plus Series Downflow Gas Furnace R801T Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department
More information