The filters for hydraulic fluids are used to protect each component in a hydraulic circuit. Port size. Micromesh 74, 105, 149
|
|
- Arthur Thomas
- 5 years ago
- Views:
Transcription
1 Hydraulic ilters H Series The filters for hydraulic fluids are used to protect each component in a hydraulic circuit. RoHS H Series Operating Port size Element (µm) nominal filtration Accessory (Option) Page Vertical Suction ilter HIA Series Suction ilter with Case H99 Series Suction Guard HG Series Line ilter H34/44/54/64 Series Vertical Return ilter HBA Series Return ilter H100 Series Oil ilter H0 Series 3.5, 7, 14, 21 MPa 1.6 MPa 1 MPa 1 MPa 2, 2 1/2, 3, 3 1/2, 4 2, 2 1/2, 3, 3 1/2, 4 2, 2 1/2, 3 3/8, 1/2, 3/4, 1, 1 1/4 1 1/2, 2, 2 1/2, 3 3/4, 1 1/4, 1 1/2 3/4, 1, 1 1/4, 1 1/2, 2 2 1/2, 3 1/4, 3/8, 1/2 () 74, 105 () Air breezer Cap Bracket Magnetic Separator HM Series
2 Vertical Suction ilter HIA Series RoHS No air pockets There are no places for air pockets to form. This prevents damage to the pump and enables normal operation to start immediately. Elimination of all collected matter All collected matter can be disposed of reliably when the element is replaced. There is no danger of collected matter dropping back into the tank. No drain port required The structure of the filter does not contain areas for drain fluid to collect, so there is no need to manually drain the pump. Easy element replacement Simply open the cover to quickly replace the element without touching the pipes. The element is extracted from the top, so no fluid can leak out. Compact and lightweight The compact and lightweight design employs an aluminum casted housing. Clogging sensor The sensor indicates when the element is becoming clogged, facilitating maintenance and helping to avoid pump damage, such as cavitations. ifferential indicator/reset type switch/visual combined, non-reset type Specifications luid Operating Operating temperature Cover/Case Main material O-ring Seal Material Element Nominal filtration ifferential resistance ifferential indicator operating (Element replacement differential ) Hydraulic fluid 80 C Aluminum casting NBR or KM Note) NBR or EPM Note) Stainless steel, Carbon steel, Aluminum, Epoxy resin µm (200, 0, 100 mesh) 0. MPa 20.0 kpa Relief valve open 26.7 kpa Note) The material of the O-rings and seals differs depending on the hydraulic fluid used. Petroleum, Water-glycol, Emulsion: NBR; Phosphoric ester: KM, EPM Model/Rated low Rate Model lange port size Note) Rated flow rate (L/min) HIA - 1/2 B 30 HIA -06 3/4 B 50 HIA B 95 HIA /4 B 0 HIA /2 B 220 HIA - 2 B 350 HIA /2 B 550 HIA B 770 HIA /2 B 1000 HIA B 1300 The symbol represented by indicates the type of applicable hydraulic fluid. N: Petroleum, W: Waterglycol, Emulsion, V: Phosphoric ester Note) itted with companion flange. (lange configuration is exclusive to SMC.) Accessory/Option escription Part no. Note ifferential indicator CB-56H Petroleum, Water-glycol, Emulsion CB-56H-V Phosphoric ester switch CB-57H Petroleum, Water-glycol, Emulsion (N.C. and N.O. common) CB-57H-V Phosphoric ester AG-12H Petroleum (for differential indication AG-12H-W Water-glycol, Emulsion part) AG-12H-V Phosphoric ester low Rate Characteristics Pressure drop (kpa) low rate (L/min) Conditions luid: Turbine oil Class 2 VG56 Viscosity: 45 mm 2 /s ilter material: Nominal filtration: 74 µm to 149 µm
3 Vertical Suction ilter HIA Series Vertical suction filter How to Order H I A N M 074 M R N W V Hydraulic fluid Petroleum Water-glycol, Emulsion Phosphoric ester Replacement Element Part No. 74 µm Port size (200 mesh) (1/2 B ) 06 (3/4 B ), 08 (1 B ) 10 (1 1/4 B ), 12 (1 1/2 B ) (2 B ) 20 (2 1/2 B ), 24 (3 B ) 28 (3 1/2 B ), 32 (4 B ) EM001H-074N EM101H-074N EM201H-074N EM301H-074N EM401H-074N EM501H-074N Port size /2 B 3/4 B 1 B 1 1/4 B 1 1/2 B 2 B 2 1/2 B 3 B 3 1/2 B 4 B Note) or flange connection only. 105 µm (0 mesh) EM001H-105N EM101H-105N EM201H-105N EM301H-105N EM401H-105N 149 µm (100 mesh) EM001H-149N EM101H-149N EM201H-149N EM301H-149N EM401H-149N EM501H-149N EM501H-105N Note 1) The symbol at the end of the element part no. indicates the hydraulic fluid type. N: Petroleum, Phosphoric ester, W: Water-glycol, Emulsion. Note 2) Above elements require one element per filter Element M M ifferential indicator E switch Note) None () Note) N.C. and N.O. common Nominal filtration Element size ø65 x 90 ø85 x 110 ø100 x 0 ø120 x 180 ø140 x 200 ø180 x µm 105 µm 149 µm Relief valve R With relief valve None (Blanking plate) H A differential indicator or a differential indication switch can be selected, and mounted on all filter models. ifferential indicator Operating 20 kpa Once a value is displayed, it will continue to be displayed until reset, even if the pump is stopped. (Reset type) Perform element replacement when the red ring floats up and covers the entire view port. ifferential Pressure Indication switch Operating 20 kpa When a value has been displayed, it will be automatically reset when the pump is stopped. (Non-reset type) This is a visual dual-purpose. Perform element replacement when the switch has actuated (when the red ring floats up and covers the entire view port). N.C. and N.O. common Refer to page 529 for Microswitch for differential indication switch. Reset button View port COM. N.O. N.C. View port G1/2 499
4 HIA Series Construction/Seal List ifferential indicator Hexagon socket head cap screw Cover Case w O-ring Wave washer q O-ring ifferential indication switch Relief valve Element e O-ring switch A r Base seal e O-ring Companion flange Hexagon head bolt IN Replacement O-ring/Seal List (One each of the seal and O-ring types listed below are required per filter.) Port size Applicable hydraulic fluid Material q O-ring order no. w O-ring order no. e O-ring order no. r Base seal order no. KA064 KA00061 KA058 (G35) (G30) AL-196H KA066 KA060 KA to 08 (G90) (G50) (G45) AL-197H KA053 KA063 KA to 12 Petroleum, AL-198H (G105) (G65) (G55) Water-glycol, NBR-70-1 KA00787 KA065 KA064 Emulsion AL-199H (G80) KA00060 KA052 KA to 24 (G145) (G100) (G95) AL-200H KA00792 KA00790 KA to 32 (G185) (G140) AL-201H KA006 KA00696 KA00695 (G35) (G30) AL-196H-V KA007 KA00699 KA to 08 (G90) (G50) (G45) AL-197H-V KA00688 KA00614 KA to 12 KM-70 AL-198H-V (G105) (G65) (G55) Phosphoric ester or KA00689 KA00702 KA006 EPM-70 AL-199H-V (G80) KA00692 KA00610 KA to 24 (G145) (G100) (G95) AL-200H-V KA00693 KA00691 KA to 32 (G185) (G140) AL-201H-V Note) The material of seals (AL-196H-V to AL-201H-V) is EPM-70. Note) The material and nominal size notations are based on JISB2401. q Mounting Confirm IN and before connecting. or maintenance, make sure to provide sufficient space above the filter for removing the element. 500 Replacement parts escription Applicable model HIAN Companion flange set HIAW HIAV Note 1) The two digit number of the port size is entered in the of the part number. Note 2) Part number N: O-ring material NBR, V: O-ring material KM Handling Precautions w Operation The hydraulic fluid used becomes high viscosity when the temperature is low during the winter, etc., and the differential indicator or the switch may activate. If this occurs, wait until the oil temperature rises by a warm-up operation, then check if this is caused by clogging. If the differential indicator is the reset type, make sure to reset it after normal operation starts in cold weather such as during winter. When using a differential indication switch, if a filter clogged signal is incorporated into the sequence circuit of the machine, make sure to design the system so the filter clogged signal does not operate until normal operation starts. Part no. HIA-L003N- HIA-L003V- Set contents Two sets each of companion flange, O-ring, hexagon head bolts e Element replacement When the difference reaches 20 kpa during filter operation (actuating the differential indicator), stop operation and either wash or replace the element. If any scratches or damage are found on the O-ring during assembly/disassembly, replace with a new O-ring. When washing the element, do not wipe it using a stiff brush or rag. After washing the element, make sure the base seal is properly mounted.
5 Vertical Suction ilter HIA Series imensions ifferential indicator ø B (34) C H H E Removal dimension K switch 62 (65) 4 x I øa øj G IN H (mm) Model HIA - HIA -06 HIA -08 HIA -10 HIA -12 HIA - HIA -20 HIA -24 HIA -28 HIA -32 A B C E G H I M8 x 25 M8 x 25 M10 x 30 M12 x 35 M12 x 35 M x 40 J K Weight (kg)
Suction Filter with Case. Specifications. Fluid Operating pressure Operating temperature Cover/Case. Model/Rated Flow Rate. Model
Suction Filter with Case FH99 Series RoHS Compact and lightweight The compact and lightweight design employs an aluminum casted housing. Prevents pump cavitation The inlet size is larger than the outlet
More informationHydraulic Filters. Element (µm) nominal filtration. Port size. Micromesh 74, 105, 149 1/2, 3/4, 1, 1 1/4, 1 1/2, 2, 2 1/2, 3, 3 1/2, 4
Hydraulic Filters Series Series Operating pressure Port size (µm) nominal filtration Accessory (Option) Page Vertical Suction Filter Series FHIA Suction Filter with ase Series FH Suction Guard Series FHG
More informationSpecifications. Fluid Operating pressure Operating temperature Cover. Material. Model/Rated Flow Rate. Port size (Rc)
Return Filter Series FH Selection of elements for different applications Depending on the application, the user can choose among several standard element types, paper elements (, and µm) and micromesh
More informationSpecifications. Model/Rated Flow Rate. Accessory/Option. Differential pressure indicator
Oil Filter FH150 Series RoHS ompact and lightweight The compact and lightweight design employs an aluminum alloy cover. Easy maintenance The element slides into place, making it easy to install and remove.
More informationFHM Series. Magnetic Separator. RoHS FH HOW
Magnetic Separator FHM Series RoHS These magnetic separators protect machinery from malfunctions, reduced precision, and burnout by adsorbing and eliminating contaminants in the fluid by means of magnetism.
More informationMicro Mist Separator. Model. Note) 1 8, , , , , 1. Model/Free Standing Type. Model AMD (2B)JIS 10K FF flange
Can separate and remove aerosol state oil mist in compressed air and remove particles such as carbon or dust of more than 0.01 μm. Use this product as a pre-filter for compressed air for precision instruments
More informationCompressed Air Cleaning Filter Series
Compressed Air Cleaning Filter Series Series / For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! Uses the same spacer as the F.R.L. combination
More informationFiltrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181
Common HYDRAULIC FILTRATION Side wall mounting suction filters Technical Information Connection Ports: 1-1 1/4-1 1/2 BSP (other thread options on request) 1 1/2 SAE J518-3000/M12 Housing Materials: Cover:
More informationLow Torque Rotary Joint
Low Torque Rotary Joint MQR Series Metal Seal Type Long service life billion rotations MQR : billion rotations MQR : 0. billion rotations MQR : 0. billion rotations MQR8 : 0. billion rotations MQR: 0.
More informationCoolant (oil-based, water-soluble) Weak alkali-based cleaning fluid Cutting fluid Industrial water. Variations. Number of elements
Bag Filter Series Optimum for the large flow filtration Easy maintenance Main operating fluids For other kinds of fluids, please contact SMC. With safety mechanism Employs proprietary SMC latch mechanism
More informationDuplex Pressure Filters
Duplex Pressure Filters Series DFDK Ball Valve Selector Pressures to 45 psi Flows to 9 gpm APPLICATIONS HYDAC DFDK Duplex Filters are ideal for use on hydraulic test equipment, robots, or other critical
More informationHIGH PRESSURE FILTERS
APPLICATION HIGH PRESSURE FILTERS For Manifold Block Mounting Series DF...P Pressures to 45 psi Flows to 18 gpm HYDAC DF...P High Pressure Filters are designed to be mounted directly onto the manifold
More informationHIGH PRESSURE FILTERS
HIGH PRESSURE FILTERS Series DF & LF Pressures to 6 PSI Flows to 18 GPM APPLICATION HYDAC DF & LF In-line High Pressure Filters are designed for use on hydraulic power units, machine tools, plastics machinery,
More informationCompressed Air Cleaning Filter Series
Compressed Air Cleaning Filter For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! AMG C, AFF C, AM C, AMD C AMH C, AME C, AMF C Uses the
More informationSpecifications. Fluid Operating pressure range Proof pressure Operating temperature range Filtration Element proof pressure differential
Air Suction Filter Series ZFA Prevents vacuum equipment trouble due to airborne contaminants. The collected dust does not remain in the case. Dust is removed easily at the time the filter element is replaced.
More informationLow Torque Rotary Joint
Low Torque Rotary Joint Series MQR Metal Seal Type K Long service life billion rotations MQR : billion rotations MQR : 0. billion rotations MQR : 0. billion rotations MQR8 : 0. billion rotations MQR: 0.
More informationD e s c r i p t i o n
D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from
More informationCoolant (oil-based, water-soluble) Weak alkali-based cleaning fluid Cutting fluid Industrial water. Variations. Number of elements
Bag Filter Series Optimum for the large flow filtration Easy maintenance Main operating fluids For other kinds of fluids, please contact SMC. With safety mechanism Employs proprietary SMC latch mechanism
More informationPressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )
HYDRAULIC FILTRATION Tank top return filters Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.1..1) Burst 16 bar (232 psi) (acc. to NFPA T 3.1..1) Housing Connection Ports:
More informationCoolant Valve. Air Operated/External Pilot Solenoid
Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page
More informationDischarge rate* 2 L/min MPa (DE10-1) 37.8 MPa (DE10-7)
D VANE PUMPS D VANE PUMPS Operating pressure MPa {kgf/cm } Maximum Rated Discharge rate* L/min Permissible min Page DS DSP 7 {7} 7 {7} to D- MD Motor pumps incorporating a DSP D-4 DP DP DP DP 7. {7} 4
More informationGraphic Symbol 100 L 140 G25. R -M V 4 4 G P E. Perm.* 2 Magnet. Differential Pressure P. Connection. R: BSP.F Thd. O: Not Fitted.
ollowing are the Accessories used in the Hydraulic Systems iller Breather Model Code Method of Representation: According to Model Code in the above table. Suction Strainer Model Code SS 15 evel Gauge iltration
More informationCompressed Air Cleaning Filter Series
Compressed Air Cleaning Filter For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! AMG C, AFF C, AM C, AMD C AMH C, AME C, AMF C Uses the
More informationSeries RFL In-Line Filter
APPLICATION Series RFL In-Line Filter Pressures 2 bar Flows to 400 l/min HYDAC RFL In-Line Filters are designed for in-line mounting. These filters can be used in hydraulic, flushing, and for extraction
More informationBy-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane
HYDRAULIC FILTRATION Spin-on, tank top return filters Technical Information Pressure: Max working 12 bar (175 psi) (acc. to NFPA T 3.10.17) Burst 20 bar (290 psi) (acc. to NFPA T 3.10.17) Connection Ports:
More informationMEDIUM PRESSURE FILTERS
Medium Pressure Filters 61-2999 psi Low-cost aluminum construction inline filters, provide flexibility for use in both mobile and industrial applications. Durable and light weight, these filters are ideal
More informationPressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)
HYDRAULIC FILTRATION Return filters, tank top mounting, inside-to-outside filtration Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.10.5.1) Burst 16 bar (232 psi) (acc. to
More informationHIGH PRESSURE FILTERS DFFX Series Reverse Flow Differential Pressure Optimized Filters 6090 psi up to 160 gpm
HIGH PRESSURE FILTERS DFFX Series Reverse Flow Differential Pressure Optimized Filters 6090 psi up to 160 gpm Hydraulic Symbol or DFFX FILTER REVERSE FLOW CIRCUIT P Indicator Reverse Flow Valve BY-PASS
More informationLow Maintenance Filter
Low Maintenance Filter FN/FN Series No more element replacement! Our unique element construction with back-flushing capability The element of the filter is constructed of a series of grooved filter plates
More informationVacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm
4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure
More informationMiniature Regulator Series ARJ310
Miniature Regulator Series 30 Compact and lightweight (Main body 65 g) 8.3 Improved flow characteristics 0. 0. 0 00 00 300 400 500 Allows smaller mounting pitch 8.8mm 0-M5 30-0 Inlet pressure: MPa Accommodates
More informationCoolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations
Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large
More informationAir Suction Filter. Series ZF. Prevent from occurring vacuum equipment trouble due to dust from vacuum pad ZFA ZFB ZFC
Air Suction Filter Series ZF Prevent from occurring vacuum equipment trouble due to dust from vacuum pad Series ZFA ZF Universal joint type Features Long maintenance cycle type (Large filter surface) Adaptable
More informationISD SO-NB-G105 SO-NB-G85 SO-NB-P46 PV2R1-* - * -RAA-42/4290 PV2R2-* - * -RAA-41/4190 PV2R3-* - * -RAA-31/3190 PV2R4-* - * -RAA-30/3090
Spare Parts List PVR-* - * -RAA-4/4 PVR-* - * -RAA-4/4 PVR-* - * -RAA-/ PVR4-* - * -RAA-/ 4 5 4 6 8 8 6 5 4 Y Section Y-Y Y 6 5 Section - 8 Cartridge Kits Model Numbers PVR-6- * -RAA-4 * PVR-8- * -RAA-4
More informationCompressed Air Cleaning Filter Series
Compressed Air Cleaning Filter For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! AMG C, AFF C, AM C, AMD C AMH C, AME C, AMF C Uses the
More informationHPK04 Max Flow: 120 gpm (454 lpm)
HIGH PRESSURE FILTERS In-Line Cartridge Filters Working Pressures to: 6000 psi 41,380 kpa 413.8 bar Rated Static Burst to: Flow Range To: 17000 psi 117,300 kpa 1173 bar 120 gpm 454 lpm Features The high
More informationHIGH PRESSURE FILTERS
APPLICATION HIGH PRESSURE FILTERS For Manifold Block Mounting Series DF...P Pressures to 4 psi Flows to 18 gpm HYDAC DF...P High Pressure Filters are designed to be mounted directly onto the manifold block
More informationStandard Specifications. Model. Port (Bypass lubrication adapter)
Centralized control of multi-point lubrication Stable oil feeding with a micromist Through the use of a booster, a pressure that is higher than that of the main air passage can be supplied. This difference
More informationAIR BREATHER SERIES OTHER FILTER TYPES DESCRIPTION
ESCRIPTION MM Air breathers are ready and easy to use filters than can be used in any applications where tank fluid often rises and falls. Air Breathers ensure system cleanliness as they filter the air
More informationHIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm
HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm Hydraulic Symbol A B Features Meets HF4 automotive standard Non-welded housing design reduces stress concentrations and prevents
More informationSeries RFLD Duplex In-Line Filter
APPLICATION Series RFLD Duplex In-Line Filter Welded Pressures to 230 psi Flows to 3900 gpm HYDAC RFLD in-line filters are designed for in-line mounting and are mainly used in continuously operating systems.
More informationAir Suction Filter / In-line Type With One-touch Fittings. Model ZFC ZFC ZFC ZFC ZFC ZFC ZFC ZFC051-03
In-line type air suction filter is used to prevent vacuum equipment trouble from occurring due to dust in the air IN/OUT straight piping Easy installation and removal with one-touch fittings Light and
More informationCoolant Valve. VNC Series. Cylinder actuation by pilot air
oolant VN Series ir Operated/xternal Pilot Solenoid [Option] ylinder actuation by pilot air Wide selection of port and variations Threaded type (6 to ) lange type (3 to 80) Low water hammer or details,
More informationPressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF
Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF up to 600 l/min, up to 315 bar 60 110 140 160 240 280 330 500 660 1.X 660 2.X 990 1320 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING
More informationNote) Rated flow (l/min (ANR)) Port size 1 8, , , , , 1 1, , 2
Mist Separator Series ohs Can remove oil mist in compressed air and separate and remove particles such as rust or carbon of more than 0.3 µm. Modular connection is possible with 150C to 550C. (For details,
More informationInline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron
NF filters are designed for inline mounting and as tank-top mounted return line filters. These filters can also be used on filling, flushing and off-line units. Inline Filters NF Flow rates up to 3,500
More informationLow Pressure Filters. Low Pressure Filters LOW PRESSURE FILTERS
Low Pressure Filters Low pressure filters are the most common type of filter found in hydraulic circuits used most often in return line applications. Low Pressure Filters Donaldson low pressure filters
More informationBody width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.
High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct
More informationHMK05/25 DURAMAX Spin-Ons
100 gpm, 378 lpm /5 DURAMAX Spin-Ons Working Pressures to: Rated Static Burst to: 350 psi 413 kpa 4.1 bar 800 psi 550 kpa 55. bar Flow Range to: 50 gpm 100 gpm 189 lpm 378 lpm Features (single) and (double)
More informationLow Maintenance Filter
Low Maintenance Filter Series FN/FN4 No more element replacement! Our unique element construction with back-flushing capability The element of the filter is constructed of a series of grooved filter plates
More informationMPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min
MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN Maximum working pressure 12 bar Flow rates to 3 l/min D e s c r i p t i o n MPS/MST The spin-on filter series is a complete product range suitable, for
More informationPUMP SCPD 56/26 DIN BY-PASS
GB INSTRUCTION MANUAL THANK YOU FOR CHOOSING SUNFAB You have chosen SCPD 56/26 DIN, a dual flow pump with differentiated flow suitable for combination vehicles with high power take off ratio and high output
More informationOdor Removal Filter. Model. Note) 1 8, , , , 3 4. Model/Free Standing Type AMF (2B)JIS 10K FF flange
fficiently can remove odor in compressed air with an activated carbon element. The unit is designed for use in the area such as a clean room where odors must be avoided. an remove odor and gas ingredients
More informationACTUATORS GENERAL CATALOG
CAD drawing data catalog is available. ACTUATORS GENERAL CATALOG ROTARY ACTUATORS VANE TYPE SERIES CONTENTS RAN (Standard Type) Basic Model and Configuration 259 Specifications 26 Order Codes 264 Dimensions
More informationA complete line of pressure differential visual and electrical indicators are available with this series of filters.
D e s c r i p t i o n FHB series filters are designed for pressure line applications where manifold mounting is a specific requirement. The manifold type filters are designed to integrate onto manifold
More informationExhaust Cleaner for Clean Room. Body size. Symbol Nil. Size 1/4 standard 3/8 standard 1/2 standard. Element construction. Stage 2 stage.
Exhaust Cleaner for Clean oom Series ohs An exhaust cleaner that can be used inside a clean room How to Order 0 0 Exhaust air cleanliness: Equivalent to ISO Class (Class 0 ed.std.0) (Consult SMC in advance,
More informationStandard Specifications. Model. Port (Bypass lubrication adapter)
Booster Lube Series 900 Centralized control of multi-point lubrication Stable oil feeding with a micromist Through the use of a booster, a pressure that is higher than that of the main air passage can
More informationACTUATORS GENERAL CATALOG
CAD drawing data catalog is available. ACTUATORS GENERAL CATALOG ROTARY ACTUATORS PISTON TYPE SERIES CONTENTS Features 1223 Specifications 1224 Inner Construction, Major Parts and Materials 1226 Order
More informationTwo Hand Control Valve
Two Hand Control Valve Series n output is available through synchronized, twohanded operation (within 0.5 s)! Conforming to EN574 RoHS (Interchangeable with XT92-67 ) Example of a basic circuit diagram
More information1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110
Best 1 Pneumatics Transmitters Relay valve P. 1900 Side piping: 30 x 53 x 91 Bottom piping: 30 x 8 x 91 VR151 VR152 Effective area (mm 2 ) Number of ports Function 7 5 Metal Spool Shuttle valve P. 1902
More informationPressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )
HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T 3.10.5.1) Burst 840 bar (12200 psi) (acc. to NFPA T 3.10.5.1) Housing
More informationAir Filter. Best Pneumatics 4. Equipment. Air Line
est Pneumatics Air Filter Air Filter: AF000 to 6000 P..- Mist Separator: AFM000/000/00 P..-6 Micro Mist Separator: AF000/000/00 P..-9 Large Flow Air Filter: AF00/0 P..- Air Line Equipment.-0 Modular Style
More informationHIGH PRESSURE FILTERS
APPLICATION HIGH PRESSURE FILTERS For Manifold Block Side Mounting Series DF...QE Pressures to 4 psi Flows to 18 gpm HYDAC DF...QE High Pressure Filters are designed to be side mounted directly onto the
More informationPressure Filter DF...K P, DF...M P, Flange Mounted
Pressure Filter, DF...M P, Flange Mounted up to 550 l/min, up to 260 bar DF...M P 330...1.X 160 240 280 500...1.X 660...1.X 660...2.X 990...2.X 1320...2.X 660...3.X 990...3.X 1320...3.X 1. TECHNICAL SPECIFICATIONS
More informationFPK02 In-Line Cartridge Filters
HIGH PRESSURE FILTERS FPK2 Max Flow: gpm (9 lpm) FPK2 In-Line Cartridge Filters Working Pressures to: Rated Static Burst to: Flow Range to: 69 psi 42, kpa 42 bar 913 psi 63, kpa 63 bar gpm 9 lpm Features
More informationFLOW CONTROL VALVES F CONTROL VALVES. Maximum operating pressure MPa {kgf/cm 2 } Model [Model No.] Maximum flow rate L/min. Page
F FLOW CONTROL VALVES F FLOW CONTROL VALVES Model [Model No.] Maximum operating pressure MPa {f/cm } Maximum flow rate 5 5 5 Page Flow control valve [SF] 7 {7} F- Flow control valve Flow control valve
More informationHD 049 HD 069 HD 172 HD 319 HD 419 HD 619 Operating pressure up to 630 bar Nominal flow rate up to 450 l/min
High Pressure ilter Kits H 9 H 9 H 7 H 9 H 9 H 9 Operating pressure up to bar Nominal flow rate up to l/min escription Application In the high pressure circuits of hydraulic systems. Performance features
More informationMedium Pressure Filters
Medium Pressure Filters Medium pressure filters can be used in applications up to psi (379 kpa). Donaldson offers both spin-on and in-line cartridge-style filters. Medium Pressure Filters Donaldson Duramax
More informationSeries AN /Series AMC
s/exhaust Cleaner / Noise reduction Nominal filtration rating (Reference values) Oil mist removal ratio Standard type Low back pressure Compact and easy mounting 00 30 db (A) 00 µm 50 µm 5-0- Compact type
More informationMedium Pressure Filters
Medium Pressure Filters Medium pressure filters can be used in applications up to 2 psi (1379 kpa). Donaldson offers both spin-on and in-line cartridge-style filters. Medium Pressure Filters MEDIUM PRESSURE
More information"PV11R" SERIES Fixed Displacement- Single PV11R10/PV11R20
"PVR" SERIES Fixed Displacement- Single PVR/PVR Up to MPa ( ),. cm /rev (. CU.IN./rev) Pub. EC- These pumps are of completely unique design for extra high pressure applications. The excessive wear to the
More informationARL1 Series Piston Pumps. ARL1 Series Piston Pumps. Geometric Displacement. Maximum cm 3 /rev
ARL1 Series Piston Pumps Geometric Displacement Maximum cm 3 /rev Operating Pump Type Graphic Symbol Pressure Page 1 2 5 10 20 50 100 150 MPa ARL1-6 Piston Pump ARL1-8 ARL1-12 7 8 ARL1-16 5 Hydraulic Fluids
More informationOUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter
D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from
More informationPilot Operated Check Valves
Pilot Operated heck Valves Nomenclature IS graphic symbols for hydraulic system L eatures - P - - - - pplicable fluid code No designation: Petroleum-based hydraulic fluid, waterglycol hydraulic fluid :
More informationChange-Over Pressure Filter DFDK
Change-Over Pressure Filter up to 2500 l/min, up to 315 bar 30 60 110 140 160 240 280 330 500 660 1.x 660 2.x 990 2.x 1320 2.x 1320 3.x 2640 3.x 3960 3.x 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING
More informationFPK04 Max Flow: 100 gpm (379 lpm)
HIGH PRESSURE FILTERS In-Line Cartridge Filters Working Pressures to: 4350 psi 30,015 kpa 300 bar Rated Static Burst to: Flow Range To: 9135 psi 63,000 kpa 630 bar 100 gpm 379 lpm Features The T-type ported
More informationNFH Low Pressure Filters
PPLICTIONS NFH Low Pressure Filters Pressures to 360 psi Flows to 450 gpm Water Removal Capability 4 Ports HYDC NFH In-line Return Filters are designed for use on hydraulic power units, machine tools,
More informationReady for outdoor use too!
Filter/regulator assured for outdoor use New Product Filter/regulator series First in the industry FILTER REGULATOR FOR DOOR USE Ready for outdoor use too! Improved outdoor durability due to the exterior
More informationStandard Specifications. Fluid Standard specifications. VH600 Ambient and fluid temperature Operating angle Lubrication. Optional Specifications
Hand Valve Series Standard Specifications Fluid Standard specifications Max.operating,, pressure Ambient and fluid temperature Operating angle Lubrication Air.5MPa.MPa MPa 5 to C (No freezing) 9 Not required/when
More informationF1000/F3000/F4000/F8000 Series
Air filter F000//F4000/F8000 Series Dust removal µm element and tar removal 0.3 µm of element, (F000 series excluded) port size: Rc/8 to Rc JIS symbol CAD DATA AVAILABLE. Specifications Descriptions F000
More informationSeries AN /Series AMC
s/exhaust Cleaner / Noise reduction Nominal filtration rating (eference values) Oil mist removal ratio Standard type Low back pressure Compact and easy mounting 00 30 db (A) 00 µm 50 µm 5-0-2 Compact type
More informationFlow rates to 500 l/min
FF 5 Filter housing in according to SE J066 for F filter elements Maximum pressure 50 bar Flow rates to 500 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing:
More informationSteam Valve. Series VND. 2 Port Valve for Steam. With indicator (Option) By adopting of PTFE seal, the valve is suited for steam.
Steam Valve Series VN Valve for Steam Valve for Steam Max. 80 y adopting of PT seal, the valve is suited for steam. ody material: ronze, Stainless steel Large valve capacity With indicator (Option) Selectable
More informationPressure Control Valves
efore using the product, please check the Pressure ontrol Valves JIS graphic symbols for hydraulic system Refer to the next page. Features These direct operated control valves can be used as sequence valves,
More informationReturn Line Filter RF
HYDAC return line filters type RF are designed to be mounted directly on tank tops. Inline mounting is also possible. Return Line Filter RF Flow rates up to 5, l/min Pressure range up to 25 bar Material:
More information3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option
Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable
More informationFHF325 series. Filter housing according to SAE J2066 for HF4 filter elements. High Pressure fi lters
High Pressure fi lters FHF5 series Maximum pressure up to 50 bar Flow rate up to 500 l/min housing according to SAE J066 for HF filter s 95 High Pressure fi lters FILTER SIZING The correct filter sizing
More informationModel Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid
Water Separator RoHS Can remove water droplets in compressed air. Use this product in cases where water must be avoided, but not so dry as when an air dryer is used. Through the adoption of an element
More informationHIGH PRESSURE FILTERS Series HF2P
HIGH PRESSURE FILTERS Series HF2P Pressures to 3000 psi Flows to 25 GPM Port Size 3/4 APPLICATION HYDAC HF2 Inline High- Pressure Filters are designed for use on hydraulic power units, machine tools, plastics,
More informationInline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar
RFL inline filters are designed for inline mounting in hydraulic and lubrication systems. Inline Filter RFL Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar * For larger flow rates,
More informationVANE PUMPS. Output Flow at 1200 r/min at No-Load U.S.GPM Maximum Operating Pressure MPa (PSI) Graphic Symbols.
B VANE PUMPS Pump Type "PVR" Series Single Pumps Graphic Symbols at r/min at No-Load.. PVR PVR PVR PVR Maximum Operating MPa (PSI) () Page Fixed Displacedment "PVRA" Series Single Pumps "PVR" Series Double
More informationPressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)
HYDRAULIC FILTRATION F8-D1 series In line medium pressure filters Technical Information Housing Pressure: Max working F8 D1x port size 1/ & 3/4 : 4 bar (6 psi) F8 D1x port size 1 : 3 bar (4 psi) F8 D14x:
More informationSpecifications VH600. Ambient temperature and operating fluid temperature. Operating angle Lubrication. Semi-standard
Hand Valve Series VH Specifications Fluid Proof pressure Max. operating VH00/00/00 pressure VH00 Ambient temperature and operating fluid temperature Air.5 MPa.0 MPa MPa -5 to 0 C (No freezing) VH0 VH00
More informationPressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces:
Pressure reducing valve, direct operated Type ZDR RE 657 Edition: 8-3 Replaces: 8- Size 6 Component series 4X Maximum operating pressure 35 bar Maximum flow 5 l/min H775 Features Sandwich plate valve Porting
More information5 Port Solenoid Valve Direct Operated Poppet Type. Specifications
Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W
More informationHYDRAULICS VINCKE HYDRAULIC PUMPS
VINCKE HYDRAULIC PUMPS TECH-VHP200.1 index 3 link to your page / link a su página Gear pumps Introduction 3 Group 0 3 Group 1 3 Group 2 3 Group 3 4 6 7 12 18 Variable displacement pumps 21 Hand pumps 3
More informationDigital Flow Switch (Sensor Part) Operation Manual
Digital Flow Switch (Sensor Part) Operation Manual For Air PF2A 50/5 Series PF2A 5/ 52/ 55 Series For Water PF2W /520/50 Series PF2W 5 Series For Water (High Temperature Fluid Type) PF2W T/520T/50T Series
More informationISO Standard Solenoid Valve/SIZEq Rubber Seal Series VP7 6
ISO Standard Solenoid Valve/SIZq Rubber Seal Series VP7 6 VP7 6 FPG D VP7 6 FG D position position Single solenoid (FG-S) Double solenoids (FG-D) Reverse pressure (YZ-S) Reverse pressure (YZ-D) Closed
More informationInstruction manual. Installation requirements. Power Take-Off. Pump mounting: Spline shaft DIN 5462 / ISO 14. Mounting flange ISO 7653-D.
GB PUMP SCPD 76/76 DIN Instruction manual Thank you for choosing Sunfab You have chosen SCPD 76/76, a dual flow pump with the highest displacement-to-size-ratio on the market. It can effectively be directly
More information2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control
Process Valve Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external pilot
More information