1 Stainless Steel Pressure Filters
2 Inline Filters up to 26,000 PSIG up to 35 GPM Description Process Filtration MPSSF / HPSSF/ ACSSF Series The pressure filters consist of two main sections: the filter head and the screw-in filter bowl. The standard model is available with and without a bypass and a pressure release plug. The connection for a clogging indicator is available on the MPSSF 450 and HPSSF 700 range. Materials Filter head: S/S AISI 316 Filter bowl: S/S AISI 318 Seals NBR (Nitrile/Buna) or FPM (Viton *) Special Models For other seals, please contact our Technical Sales department. For flange connections and other thread forms, please contact our Technical Sales department. Accessories Visual clogging indicator The clogging indicators must be tightened to the recommended torque of 37 lb-ft (50 Nm). Element Hardware Available With Nickel plated steel (typical for mineral oils, etc.) Stainless steel (typical for water and water with glycol) Cleaning of Elements Please note: Only wire mesh (D) and metal fiber (M) elements can be cleaned. Filter elements type Betamicron (BN/HC, BH/ HC) cannot be cleaned. *Viton is a registered trademark of Dupont Technical Details Mounting Method Mounting Position Flow Direction Inline Manifold Mounting Max. Operating Pressure MPSSF HPSSF ACSSF 4 mounting holes in filter head Vertical Inlet/Outlet: side connection At the same level, on opposite sides Inlet/Outlet: top face 6,500 psig (450 bar) max. 10,150 psig (700 bar) max. 26,000 psig (1800 bar) max. Element Collapse Pressure Rating Betamicron -H (BH/HC) 3046 psi (210 bar) Betamicron -N (BN/HC) 363 psi (25 bar) Metal fiber (M) 3046 psi (210 bar) Wire mesh (D) 3046 psi (210 bar) Fluid Temperature Range 14 to 212 F (-10 to 100 C) Fluid Compatibility Mineral oils: test criteria to ISO 2943 Lubricating oils: test criteria to ISO 2943 Water and water glycols For use with non-flammable fluids, synthetic oils and rapidly biodegradable oils etc., please contact HYDAC Technical Sales. Flow Fatigue Limit to ISO 3724 High fatigue limit resistance due to solid filter material supports and high inherent stability of filter materials. Pressure Setting of Clogging Indicator P = 72 psi (5 bar) (standard) Bypass Valve Cracking Pressure P = 87 psid (6 bar) (standard) 2 Stainless Steel Pressure Filters
3 Process Filtration Model Code MPSSF450 BH/HC 60 N2 005 B X / -V Filter Type MPSSF 450 = 6500 psig (450 bar) operating pressure HPSSF 700 = psig (700 bar) operating pressure ACSSF 1000 = psig (1000 bar) operating pressure (Higher pressures available contact HYDAC) Filter Media BH/HC = Betamicron -BH/HC element BN/HC = Betamicron -BN/HC element absolute filtration M = Metal Fiber Chemicron S/S element D = Wire Mesh S/S element nominal filtration Size 30, 60, 110, 160, 240, 280 Type of Connection B = BSPP (G) threaded connection N = NPT threaded connection S = SAE threaded connection A = autoclave (20,000 psi) form AE medium pressure (20,000 psi) P = manifold mounting (top interface) (only available in certain models) Model Code Model Sizes BSPP/NPT SAE Model Sizes Autoclave 0 = 30, 60, 110 1/4 SAE-4 60, 110, 160, 240, 280 9/ = 60, 110 3/8 SAE-6 60, 110, 160, 240, / = 30, 60, 110, 160, 240, 280 1/2 SAE = 60, 110, 160, 240, 280 3/4 SAE = 160, 240, SAE = 160, 240, /4 SAE Filtration Rating (micron) 3 Betamicron High Collapse (BH/HC) 5 Betamicron Low Collapse (BN/HC) 10 Absolute Filtration Rating (ß x(c) 1000) 20 Nickel Plated Carbon Steel Hardware 3 Betamicron High Collapse (BH/HC) 5 Betamicron Low Collapse (BN/HC) 10 Absolute Filtration Rating (ß x(c) 1000) 20 Stainless Steel Hardware 1 3 Chemicron S/S (M) 5 Metal Fiber 10 Absolute Filtration Rating Wire Mesh S/S (D) 100 Nominal Filtration Rating Type of Clogging Indicator A = no clogging indicator B = with visual clogging indicator C = with electrical clogging indicator D = with visual/electrical clogging indicator Modification Number (latest version always supplied) Supplementary Details -V = FPM (Viton ) seals -W = BH/HC, BN/HC, or D elements with stainless steel hardware -B6 = with bypass valve (87 psi (6 bar) cracking pressure) -TB6 = with triple bypass valve (87 psi (6 bar) cracking pressure) -/RC = with reverse flow check -EXENC = indicator with explosion proof enclosure -IS = intrinsically safe sensor Model Codes Containing RED are non-stock items Minimum quantities may apply Contact HYDAC for information and availability Stainless Steel Pressure Filters 3
4 Process Filtration MPSSF / HPSSF Inline Series Dimensions MPSSF / HPSSF 30 M8x1.25 by 12 full form on 50 pcd ø 2.60 (66mm) 1.42 (36mm) 1.34 (34mm) 8.11 (206mm) Clearance Required for Element Removal 2.95 (75mm).47 (12mm) Outlet Material Spec. Part No. Across Flats.24 (6mm) Inlet 1/4 NPT Ports MPSSF / HPSSF (116mm) B 1.44 (36.5mm) H2 B Indicator B Material Spec. Model Code D1 Part No. H1.39 (10mm) x.63 (16mm) H3 SW2 H4 D2 Clearance Required for Element Removal Drain Plug Drain Size 1/4 BSP for MPSSF 7/16 AC for HPSSF Size B D1 D2 H1 H2 H3 H4 SW2 Weight MPSSF 60 MPSSF 110 MPSSF 160 MPSSF 240 MPSSF 280 HPSSF 60 HPSSF 110 HPSSF 160 HPSSF (70mm) 2.75 (70mm) 4.33 (110mm) 4.33 (110mm) 7.24 (184.0mm) 9.90 (251.5mm) 9.13 (232.0mm) (289.0mm) (499.0mm) 7.40 (188.0mm) (255.5mm) 9.13 (232.0mm) (289.0mm) 1.30 (33mm) 1.30 (33mm) 1.30 (33mm) 1.30 (33mm) Dimensions are for general information only, all critical dimensions should be verified by requesting a certified print. Dimensions are in inches/(mm) and lbs/(kg) N/A N/A N/A N/A 2.16 (55mm) 2.16 (55mm) 29.1 (13.2) 41.2 (18.7) 68.1 (30.9) 92.4 (41.9) (57.3) 38.8 (17.6) 48.5 (22.0) (48.5) (59.5) 4 Stainless Steel Pressure Filters
5 Process Filtration MPSSF / HPSSF Manifold Mount 60 P / 160 P / 240 P ø.60 (15.30mm) L 1 (25.40mm) W ø.39 (10.00mm) Outlet Inlet Material Cert (60.00mm) Thread Depth holes ø 13 for M12 socket cap screw, 4 places.79 (20.00mm) BM Indicator 1.57 (40.00mm).98 (25.00mm) A1.16 (4.00mm) (80.00mm) Across Flats Drain Plug Drain Size 1/4 BSP for MPSSF 7/16 AC for HPSSF A2 Size A1 A2 W L PCD* Weight MPSSF 60 P MPSSF 160 P MPSSF 240 P HPSSF 60 P HPSSF 160 P HPSSF 240 P 7.91 (201mm) 8.03 (204mm) (261mm) 7.91 (201mm) 8.03 (204mm) (261mm) 2.75 (70mm) 3.00 (76.2mm) 4.49 (114mm) 4.49 (114mm) 3.46 (88mm) 3.46 (88mm) 5.70 (145mm) 5.70 (145mm) 5.70 (145mm) 5.70 (145mm) Dimensions are for general information only, all critical dimensions should be verified by requesting a certified print. Dimensions are in inches/(mm) and lbs/(kg) *Pitch circle diameter 3.00 (76.2mm) 4.90 (124.5mm) 4.90 (124.5mm) 3.00 (76.2mm) 4.90 (124.5mm) 4.90 (124.5mm) 36.4 (16.5) 64.8 (29.4) 91.9 (41.7) 38.8 (17.6) (46.3) (57.3) Stainless Steel Pressure Filters 5
6 Sizing Information Total pressure loss through the SSF filters are as follows: Assembly ΔP = Housing ΔP + Element ΔP Housing Curve Pressure loss through housing is as follows: Housing ΔP = Housing Curve ΔP x Actual Specific Gravity 0.86 Process Filtration Adjustments must be made for viscosity & specific gravity of the fluid to be used! MPSSF & HPSSF Size 30 housing, with 1/4 ports MPSSF & HPSSF Size 30 housing, with 1/2 ports MPSSF & HPSSF Sizes 60 & 110 housing, with 3/4 ports MPSSF & HPSSF Sizes 160 & 240 housing, with 1 ports Note: Flow characteristics according to ISO 3968 using ISO VG32 hydraulic oil 6 Stainless Steel Pressure Filters
7 Process Filtration Model Code Betamicron Spare Element Size 0030, 0060, 0110, 0160, 0240, 0280 Element Type D = Pressure filter element Filtration Rating (microns) Absolute 010 Nickel Plated Carbon Steel Hardware Absolute 010 Stainless Steel Hardware 020 Filtration Material BN//HC = Betamicron -N element Low Collapse = 363 psi (25 bar) BH/HC = Betamicron -H element High Collapse = 3046 psi (210 bar) Seals V = FPM (Viton ) (standard) N = NBR (Nitrile/Buna) Options SS-S0361 = Stainless Steel Hardware and Wire Mesh Support Layers 0060 D 003 BH/BN / - V SS-S0361 Model Code Chemicron Wire Mesh Spare Element 060 DH 100 D - V Size 030, 060, 110, 160, 240, 280 Element Type DH = Pressure filter element Filtration Rating (microns) Absolute (Chemicron ) Nominal (wire mesh) Filtration Material M = Chemicron D = Wire mesh Seals V = FPM (Viton ) (standard) N = NBR (Nitrile/Buna) Model Codes Containing RED are non-stock items Minimum quantities may apply Contact HYDAC for information and availability Stainless Steel Pressure Filters 7
8 Accumulators Filters Fluid Service Products Valves Clamps Accessories Electronics Cooling Systems Compact Power Units Cartridge Valves Mobile Systems USA HYCON Division 2260 City Line Road Bethlehem, PA GO HYDAC Hydraulic Division 445 Windy Point Drive Glendale Heights, IL (630) Fry Road Suite 100 Houston, TX (281) Accumulator Division 2280 City Line Road Bethlehem, PA GO HYDAC Electronic Division 2260 City Line Road Bethlehem, PA GO HYDAC Mission Park Drive Suite 108 Rancho Cucamonga, CA (909) NE 95th Street Building VC, Suite 100 Vancouver WA Canada 14 Federal Road Welland Ontario, Canada L3B 3P Mexico HYDAC INTERNATIONAL SA DE CV AV. Pirul No los Reyes Iztacala, Tianepantla EDO. DE Mexico AVE W EDMONTON AB, Canada T5S 2P Copyright 2008 Stainless Steel Pressure Filters Brochure # / 4.08
Stainless Steel Pressure Filters Housings, Elements, Indicators & Sizing
Stainless Steel Pressure Filters Housings, Elements, Indicators & Sizing TABLE OF CONTENTS Page: MPSSF / HPSSFH / ACSSF Series.....2 VDHA Series...8 ACSSFH-1035...10 EDFR Series....12 EMLF Series....14
More informationHIGH PRESSURE FILTERS
APPLICATION HIGH PRESSURE FILTERS For Manifold Block Mounting Series DF...P Pressures to 45 psi Flows to 18 gpm HYDAC DF...P High Pressure Filters are designed to be mounted directly onto the manifold
More informationHIGH PRESSURE FILTERS
HIGH PRESSURE FILTERS Series DF & LF Pressures to 6 PSI Flows to 18 GPM APPLICATION HYDAC DF & LF In-line High Pressure Filters are designed for use on hydraulic power units, machine tools, plastics machinery,
More informationDuplex Pressure Filters
Duplex Pressure Filters Series DFDK Ball Valve Selector Pressures to 45 psi Flows to 9 gpm APPLICATIONS HYDAC DFDK Duplex Filters are ideal for use on hydraulic test equipment, robots, or other critical
More informationCourtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)
Features MF Filters are manufactured with an aluminum head. MF, MFD, MFDS Series Spin-On Filters Choice of NPT, SAE straight thread O-ring boss, BSPP, and SAE 4-bolt flange porting to allow easy installation
More informationHIGH PRESSURE FILTERS Series HF2P
HIGH PRESSURE FILTERS Series HF2P Pressures to 3000 psi Flows to 25 GPM Port Size 3/4 APPLICATION HYDAC HF2 Inline High- Pressure Filters are designed for use on hydraulic power units, machine tools, plastics,
More informationHIGH PRESSURE FILTERS
APPLICATION HIGH PRESSURE FILTERS For Manifold Block Mounting Series DF...P Pressures to 4 psi Flows to 18 gpm HYDAC DF...P High Pressure Filters are designed to be mounted directly onto the manifold block
More informationLow Pressure Filters
MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM Hydraulic Symbol /80/85/160/180 MF 90/95/190/195 A A B B Features MF Filters are manufactured with an aluminum head. Choice of NPT, SAE straight
More informationHIGH PRESSURE FILTERS
APPLICATION HIGH PRESSURE FILTERS For Manifold Block Side Mounting Series DF...QE Pressures to 4 psi Flows to 18 gpm HYDAC DF...QE High Pressure Filters are designed to be side mounted directly onto the
More informationHIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm
HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm Hydraulic Symbol A B Features Meets HF4 automotive standard Non-welded housing design reduces stress concentrations and prevents
More informationSeries RFL In-Line Filter
APPLICATION Series RFL In-Line Filter Pressures 2 bar Flows to 400 l/min HYDAC RFL In-Line Filters are designed for in-line mounting. These filters can be used in hydraulic, flushing, and for extraction
More informationSelector Valve RV 713
Selector Valve RV 713 Key valve features RV 713 is a 3 way selector valve designed for flows up to 42gpm (160 Lpm) and max. operating pressures up to 3,625 psi (250 bar). Spools, both 2 and 3 position,
More informationMEDIUM PRESSURE FILTERS
Medium Pressure Filters 61-2999 psi Low-cost aluminum construction inline filters, provide flexibility for use in both mobile and industrial applications. Durable and light weight, these filters are ideal
More informationHYDRAULIC AND LUBE OIL FILTERS RFM Series
HYDRAULIC AND LUBE OIL FILTERS RFM Series Low Pressure In-Tank Return Line Filters psi up to gpm Technical Details Mounting Method 7/9///8 mounting holes - filter housing Features The compact and lightweight
More informationReplacement Elements
Pressure Elements Used in OFS Series, OFCS & OFCD Series, OFAS & OFAD Series, OF5HS & OF5HD Series, and OFX Skid - Standard Capacity Series 9 inch Elements 18 inch Elements 27 inch Elements Part No. Part
More informationMEDIUM PRESSURE FILTERS MFX Series Inline Filters 725 psi up to 35 gpm Hydraulic Symbol
MFX Series Inline Filters 725 psi up to 35 gpm Hydraulic Symbol A B Features Eco-friendly, cost-effective alternative to spin-on filters Integrated retrofit protection Longer service life of the filter
More informationFilters. DFFH & DFFHM Series Service and Parts. Index. This symbol is followed by user tips and particularly useful information
142.9 INLET 1.38 35 OUTLET Index 1.25 31.8 1. General 1.4 Tools Required for Maintenance 1.5 Torque Requirements 2. Maintenance 3. Changing the Element 4. Spare Parts List 5. Replacement Element Model
More informationSPIN-ON FILTERS & ELEMENTS
ABSOLUTE RATED (BETA SPIN ) & NOMINAL RATED SPIN-ON FILTERS & ELEMENTS Single and Twin Element Models Pressures to 20 psi Flows to 120 gpm APPLICATION HYDAC Spin-On Filters are for filtration of hydraulic
More informationSeries RFLD Duplex In-Line Filter
APPLICATION Series RFLD Duplex In-Line Filter Welded Pressures to 230 psi Flows to 3900 gpm HYDAC RFLD in-line filters are designed for in-line mounting and are mainly used in continuously operating systems.
More informationLow Pressure Filters
In-Tank Return Line Filters PSI up to GPM Hydraulic Symbol: INLET INLET Bypass Valve Pop-up Breather Bypass Valve Pop-up TANK OUTLET TANK OUTLET TANK OUTLET Features: The compact and lightweight design
More informationFilters. HF4R Series. Service and Parts. Index. Inlet. Outlet. ø7 (ø177.8mm) Bolt Circle ø6.25 (ø158.8mm) ø0.44 (ø11.1mm) 4 Places Equally spaced
ø7 (ø177.8mm) Clearance Required for Element Removal HF4R-9 10 (254mm) HF4R-18 19 (487mm) HF4R-27 28 (711mm) 2.38 (60.4mm) 4.26 (108.1mm) Filters G 1/2 Indicator Port HF4R Series 1/8 NPT Indicator Port
More informationLow Pressure Filters
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (8) 6-8 www.cmafh.com RFM Series In-Tank Return Line Filters Features The compact and lightweight design make
More informationNFH Low Pressure Filters
PPLICTIONS NFH Low Pressure Filters Pressures to 360 psi Flows to 450 gpm Water Removal Capability 4 Ports HYDC NFH In-line Return Filters are designed for use on hydraulic power units, machine tools,
More informationMonoblock Directional Control Valve RM 230
Monoblock Directional Control Valve RM 230 Key valve features RM 230 light is a monoblock valve, designed for max. operating pressures up to 3,000 psi (210 bar) and typ. pump flows up to 20 gpm (70 Lpm).
More informationHIGH PRESSURE FILTERS DFFX Series Reverse Flow Differential Pressure Optimized Filters 6090 psi up to 160 gpm
HIGH PRESSURE FILTERS DFFX Series Reverse Flow Differential Pressure Optimized Filters 6090 psi up to 160 gpm Hydraulic Symbol or DFFX FILTER REVERSE FLOW CIRCUIT P Indicator Reverse Flow Valve BY-PASS
More informationInline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron
NF filters are designed for inline mounting and as tank-top mounted return line filters. These filters can also be used on filling, flushing and off-line units. Inline Filters NF Flow rates up to 3,500
More informationHIGH PRESSURE FILTERS DF/DFF 1500 Series Inline Filters 6090 psi up to 250 gpm
HIGH PRESSURE FILTERS DF/DFF 1500 Series Inline Filters 6090 psi up to 250 gpm Hydraulic Symbol DFF FILTER REVERSE FLOW CIRCUIT Bypass Valve Filter Element Pop-up Indicator Features Available in T ported
More informationFilters. HF2P 79.4 Series Service and Parts. Index P Clogging. Indicator Port G 1/
2.05 52 3.39 86 0.24 6 0.84 21.4 P Clogging Filters Indicator Port G 1/2 4.02 102 3.13 HF2P 79.4 Series Service and Parts INLET OUTLET This symbol is followed 3.86 by user tips and particularly useful
More informationReturn Line Filter RF
HYDAC return line filters type RF are designed to be mounted directly on tank tops. Inline mounting is also possible. Return Line Filter RF Flow rates up to 5, l/min Pressure range up to 25 bar Material:
More informationPressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF
Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF up to 600 l/min, up to 315 bar 60 110 140 160 240 280 330 500 660 1.X 660 2.X 990 1320 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING
More informationPressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 500 l/min Pressure range up to 315 bar Material: SG Iron/ADI, Steel
Manifold Mounted, Rear Flanged Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 5 l/min Pressure range up to 35 bar Material: SG Iron/ADI, Steel . DESCRIPTION.. FILTER HOUSING
More informationFilters. HF3P Series Places 60 b c x d DP 4 Places Flange
1/2"-20UNF x 17 2.36 4 Places 60 b 6.42 163 5.23 133 4.53 115 c x d DP 4 Places a 6.30 Filters 160 6.42 163 Flange 2.05 0.24 52 6 P Clogging HF3P Series Indicator Port G 1/2" Service and Parts 6.30 160
More informationPRESSURE FILTERS FOR MODULAR STACKING. Series DF-Z Pressures to 4500 psi Flows to 10 gpm APPLICATION PRODUCT FEATURES FILTER ELEMENTS
PRESSURE FILERS FOR MODULAR SACKING Series DF-Z Pressures to 4500 psi Flows to 10 gpm APPLICAION DF...Z Pressure filters are designed for modular stacking and can be mounted directly to the component to
More informationChange-Over Pressure Filter DFDK
Change-Over Pressure Filter up to 2500 l/min, up to 315 bar 30 60 110 140 160 240 280 330 500 660 1.x 660 2.x 990 2.x 1320 2.x 1320 3.x 2640 3.x 3960 3.x 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING
More informationBreathers. BF...3 & BF...4 Series INNOVATIVE FLUID POWER. ø D1 HEX. Specifications. Hydraulic Symbols. Model Code. Dimensions BF P 3 G 10 W 1.0 /.
BF...3 & BF...4 Series Maximum flow rate - 31 scfm / 230 gpm at 0.04 bar Epoxy coated steel cap Zinc-plated internals Threaded connection Pressurized breather with relief valve (optional - BF3 only) Phenolic
More informationLOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM
MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM Hydraulic Symbol MF 80/85/160/180 MF 90/95/190/195 A A (Standard) (Suction) B B Features MF Filters are manufactured with an aluminum head. Choice
More informationLOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM
LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM Hydraulic Symbol MF 80/85/160/180 MF 90/95/190/195 A A (Standard) (Suction) B B Features MF Filters are manufactured with
More informationPressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX
Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX up to 2000 l/min, up to 420 bar DF/DFF...1.X/2.X 30 60 110 140 160 240 280 330 500 660 990 1320 1500 2000 3000 4000 DF...3.X DFFX...1.X/2.X
More informationPressure Filter DF...K P, DF...M P, Flange Mounted
Pressure Filter, DF...M P, Flange Mounted up to 550 l/min, up to 260 bar DF...M P 330...1.X 160 240 280 500...1.X 660...1.X 660...2.X 990...2.X 1320...2.X 660...3.X 990...3.X 1320...3.X 1. TECHNICAL SPECIFICATIONS
More informationInline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04
Inline Filter MFM Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS 400-15 / steel 1. TECHNICAL SPECIFICATIONS 1.1. FILTER HOUSING Construction The inline filter consists of a filter
More informationLOW PRESSURE FILTERS RF Series In-tank / Inline Filters 360 psi up to 400 gpm
LOW PRESSURE FILTERS RF Series In-tank / Inline Filters 36 psi up to 4 gpm Hydraulic Symbol A D2 Features RF 3 filters are constructed of polyamide plastic. RF 6-33 filters are constructed of aluminum
More informationLOW PRESSURE FILTERS RFM Series In-Tank Return Line Filters 145 psi up to 224 gpm
LOW PRESSURE FILTERS RFM Series In-Tank Return Line Filters 145 psi up to 4 gpm Technical Specifications Mounting Method 75/9/15/165/185 mounting holes - filter housing D5 Features The compact and lightweight
More informationInline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar
RFL inline filters are designed for inline mounting in hydraulic and lubrication systems. Inline Filter RFL Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar * For larger flow rates,
More informationLPF Series Service and Parts
Filters LPF Series Service and Parts up to 140 GPM(280 l/min), up to 1000PSI(50bar) 1. Maintenance 1.1 General Please follow the maintenance instructions. 1.2 Installation Before installing the filter
More informationReturn Line Filter HF4R up to 450 l/min, up to 10 bar
Return Line Filter HF4R up to 450 l/min, up to 10 bar 9" 18" 27" 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed in accordance with international regulations.
More informationNFHD Modular Duplex Filter System Pressures to 360 psi Flows to 450 gpm 4 Ports
NFHD Modular Duplex Filter System Pressures to 360 psi Flows to 450 gpm 4 Ports PPLICTIONS HYDC NFHD Return Line Filters are designed for use on hydraulic power units, machine tools, plastics injection
More informationInline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01.
Change-Over Inline Filter RFLD Cast Version Flow Rates up to 3 l/min* Pressure Range 25/4/64 bar With Ball Change-Over Valve * For higher flow rates, please refer to brochure RFLD Welded Version E 7.9.2/.4
More informationFILTER ELEMENTS. Overview of Elements PN# / / FIL
Overview of Elements C1 Overview of Elements Optimicron Elements ON - code designation Glass fiber, multi-layered with support Collapse rating - 29 psid (2 bar) 1, 3, 5, 1, 15, 2 micron Filtration Rating
More informationInline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar
Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar 160 240 260 280 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed in accordance with international
More informationReturn Line Filter RF
Return Line Filter up to 15000 l/min, up to 25 bar 30 60 110 160 240 330 450 580 660 950 1300 2500 4000 5200 6500-7800 15000 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings
More informationChange-Over Inline Filter RFLD Weld Version
Change-Over Inline Filter RFLD Weld Version up to 15000 l/min, up to 16 bar RFLD 1300 CAS to RFLD 15000 CBW 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The fi lter housings are designed
More informationRFN Series Service and Parts
Filters RFN Series Service and Parts up to 166 gpm (630 l/min), up to 145 psi (10 bar) 1. Maintenance 1.1 General Please follow the maintenance instructions. 1.2 Installation Before installing the filter
More informationHPK04 Max Flow: 120 gpm (454 lpm)
HIGH PRESSURE FILTERS In-Line Cartridge Filters Working Pressures to: 6000 psi 41,380 kpa 413.8 bar Rated Static Burst to: Flow Range To: 17000 psi 117,300 kpa 1173 bar 120 gpm 454 lpm Features The high
More informationFilters. RFD Series. Change-Over Return Line Filter Service and Parts. 2. Element Replacement. 2.1 Element Removal
1. Maintenance Filters Series Change-Over Return Line Filter Service and Parts up to 343 gpm (1300 l/min), up to 362 psi (420 bar) 1.1 General Please follow the maintenance instructions. 1.2 Installation
More informationRKM Series Service and Parts
Filters RKM Series Service and Parts up to 211 gpm (800 l/min), up to 145 psi (10 bar) 1. Maintenance 1.1 General Please follow the maintenance instructions on the last page. 1.2 Installation Before installing
More informationFilters. DFP, DFPF Series. 2. Element Replacement. 2.1 Element Removal
Filters DFP, DFPF Series Manifold Mounted/Reverse Flow Option Service and Parts up to 158 gpm (600 l/min), up to 4500 psi (315 bar) 1. Maintenance 1.1 General Please follow the maintenance instructions.
More informationHFM Series Service and Parts
Filters HFM Series Service and Parts up to 37 gpm (140 l/min), up to 5800 psi (400 bar) 1. Maintenance 1.1 General Please follow the maintenance instructions. 1.2 Installation Before installing the filter
More informationLF & LFF Series Service and Parts
Filters LF & LFF Series Service and Parts up to 174 GPM(660 l/min), up to 1500PSI(100bar) 1. Maintenance 1.1 General Please follow the maintenance instructions. 1.2 Installation Before installing the filter
More informationRFL Cast Series Service and Parts
Filters RFL Cast Series Service and Parts up to 343 gpm (1300 l/min), up to 580 psi (40 bar) 1. Maintenance 1.5 Torque Values 2. Element Replacement 1.1 General Please follow the maintenance instructions.
More informationConnection Ports: 3/4 1 1/4 BSP (other thread options on request)
HYDRAULIC FILTRATION Medium pressure, in line spin-on filters Technical Information Pressure: Max working (acc. to NFPA T 3.10.17): FA-4-1x: 34,5 bar (500 psi) FA-4-21: 24 bar (348 psi) Burst (acc. to
More informationFluid Cooling Industrial COLW Series
Fluid Cooling Industrial COLW Series 0916 COPPER & STEEL CONSTRUCTION Performance Notes Ideal for independent cooling and filtering of system oils Utilizes a high efficient EK series shell & tube (finned
More informationBy-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane
HYDRAULIC FILTRATION Spin-on, tank top return filters Technical Information Pressure: Max working 12 bar (175 psi) (acc. to NFPA T 3.10.17) Burst 20 bar (290 psi) (acc. to NFPA T 3.10.17) Connection Ports:
More informationNF, NF UHE, NFD UHE & NF MMP with 2600 R element (for Ecomicronfit ( D) element version, see NF 1314/2614 Eco-Fit Series) Service and Parts
NF Series NF UHE, NFD UHE, & NF MMP refer to schematics below.. Maintenance. General Please follow the maintenance instructions.. Installation Before installing the filter into the system, check that the
More informationDuplex Filter NFD (for NFD UHE (ultra-high efficiency), see NF Series) Service and Parts
Filters Duplex Filter NFD (for NFD UHE (ultra-high efficiency), see NF Series) Service and Parts up to 747 gpm (10400 l/min), up to 360 psi (5 bar) 1. Maintenance General Please follow the maintenance
More informationFiltrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181
Common HYDRAULIC FILTRATION Side wall mounting suction filters Technical Information Connection Ports: 1-1 1/4-1 1/2 BSP (other thread options on request) 1 1/2 SAE J518-3000/M12 Housing Materials: Cover:
More informationChange-Over Inline Filter RFLD Welded Version
Change-Over Inline Filter RFLD Welded Version up to 15000 l/min, up to 16 bar RFLD 1300 CAS to RFLD 15000 CBW 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed
More informationHMK05/25 DURAMAX Spin-Ons
100 gpm, 378 lpm /5 DURAMAX Spin-Ons Working Pressures to: Rated Static Burst to: 350 psi 413 kpa 4.1 bar 800 psi 550 kpa 55. bar Flow Range to: 50 gpm 100 gpm 189 lpm 378 lpm Features (single) and (double)
More informationDF, DFF & DFFX Series Service and Parts
Filters DF, DFF & DFFX Series Service and Parts up to 528 gpm (2000 l/min), up to 6000 psi (420 bar) 1. Maintenance General Please follow the maintenance instructions. 1.2 Installation Before installing
More informationInline Filters for Process Technology
Inline Filters for Process Technology Inline Filters for Every Process. HYDAC inline filters feature high filtration capacity and easy handling and therefore contribute to safe and economical system operation.
More informationInline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure
Inline filters up to 3500 l/min, up to 25 bar 160 240 280 330 500 750 950 1350 2650 on request 1310 2.x on request 2610 2.x 1340 2640 5240 7840 10440 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction
More informationSPIN-ON FILTER - LOW PRESSURE LINE
SERIES MSH SPIN-ON FILTER - LOW PRESSURE LINE Maximum working pressure 5 psi Flow rate to 8 GPM D e s c r i p t i o n MSH working pressure of 5 psi, with a peak pressure This filter MSH series utilises
More informationMDF Series Service and Parts
Filters MDF Series Service and Parts up to 92 gpm (350 l/min), up to 4000 psi (280 bar) 1. Maintenance 1.1 General Please follow the maintenance instructions. 1.2 Installation Before installing the filter
More informationReturn Line Filter RFM with 4-Hole Mounting
Return Line Filter with 4-Hole Mounting Tank-top mounted versions: up to 850 l/min, up to 10 bar 75 90 150 165 185 210 270 330 500 600 661 851 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction
More informationLF/LFM - Low Pressure High Flow Assemblies LF flow rate to 560 lpm, 150 gpm / LFM flow rate to lpm, 4500 gpm.
HY-PRO FILTRATION LF/LFM - Low Pressure High Flow Assemblies LF flow rate to 560 lpm, 150 gpm / LFM flow rate to 16875 lpm, 4500 gpm Features, Benefits, Advantages Carbon steel construction standard (304
More informationOFFLINE FILTRATION SYSTEMS
Offline Filtration Systems Today s hydraulic filter systems have seen a shift from reactionary to preventative, and even predictive maintenance. Total system contamination management begins with our Fluid
More informationFPK04 Max Flow: 100 gpm (379 lpm)
HIGH PRESSURE FILTERS In-Line Cartridge Filters Working Pressures to: 4350 psi 30,015 kpa 300 bar Rated Static Burst to: Flow Range To: 9135 psi 63,000 kpa 630 bar 100 gpm 379 lpm Features The T-type ported
More informationFPK02 In-Line Cartridge Filters
HIGH PRESSURE FILTERS FPK2 Max Flow: gpm (9 lpm) FPK2 In-Line Cartridge Filters Working Pressures to: Rated Static Burst to: Flow Range to: 69 psi 42, kpa 42 bar 913 psi 63, kpa 63 bar gpm 9 lpm Features
More informationInline filter with filter element according to DIN Type 350LEN0040 to 1000; 350LE0130, 0150
Inline filter with filter element according to DIN 24550 Type 350LEN0040 to 1000; 350LE0130, 0150 RE 51422 Edition: 2015-03 Replaces: 07.11 Size as per DIN 24550: 0040 to 1000 Other sizes: 0130, 0150 Nominal
More informationConnection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)
HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1.5.1): F1-XD4/63/1: 1 bar (15 psi) F1-XD16/25/4: 8 bar (12 psi) Housing Burst (acc. to
More informationPressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)
HYDRAULIC FILTRATION F8-D1 series In line medium pressure filters Technical Information Housing Pressure: Max working F8 D1x port size 1/ & 3/4 : 4 bar (6 psi) F8 D1x port size 1 : 3 bar (4 psi) F8 D14x:
More informationPressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )
HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T 3.10.5.1) Burst 840 bar (12200 psi) (acc. to NFPA T 3.10.5.1) Housing
More informationPressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)
HYDRAULIC FILTRATION Return filters, tank top mounting, inside-to-outside filtration Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.10.5.1) Burst 16 bar (232 psi) (acc. to
More informationA complete line of pressure differential visual and electrical indicators are available with this series of filters.
D e s c r i p t i o n FHB series filters are designed for pressure line applications where manifold mounting is a specific requirement. The manifold type filters are designed to integrate onto manifold
More informationAP212HP Cast Iron Gear Pumps
Cast Iron Gear Pumps Standard and Low Noise series Reference: 200-P-991236-EN-01 Issue: 09.2016 1/56 Contents Page 1 General information... 5 1.1 External gear pumps components... 6 1.2 Technical data...
More informationLine filter with filter element according to DIN 24550
Line filter with filter element according to DIN 2455 RE 51423/9.12 Replaces: 7.1 1/2 Type 445LEN4 to 1 Size according to DIN 2455: 4 to 1 Nominal pressure: 45 bar [6527 psi] Connection up to G 1 1/2;
More informationD e s c r i p t i o n
D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from
More informationSRK-COMBO. Return & Suction Filters Low Pressure Filter In-Tank up to 10 bar. Filter Elements Emergency Suction
Return & Suction Filters Low Pressure Filter In-Tank up to 10 bar Technical Data Filter Elements Main Operating pressure up to 1000 kpa (10 bar). Static pressure testing up to 1500 kpa (15 bar). Back pressure
More informationReturn Line Filter RFM with 4-Hole Mounting
Return Line Filter with 4-Hole Mounting Tank-top mounted versions: up to 850 l/min, up to 10 bar 75 90 150 165 185 195 210 270 330 500 600 661 851 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction
More informationSERIES SF2-250 SUCTION FILTER. Flow rate to 45 gpm
SERIES SF2-250 SUCTION FILTER Flow rate to 45 gpm D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows
More informationPressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )
HYDRAULIC FILTRATION Tank top return filters Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.1..1) Burst 16 bar (232 psi) (acc. to NFPA T 3.1..1) Housing Connection Ports:
More informationDFDK Series Service and Parts
Filters DFDK Series Service and Parts up to 158 gpm (600 l/min), up to 4500 psi (315 bar) 1. Maintenance 1.1 General Please follow the maintenance instructions. 1.2 Installation Before installing the filter
More informationInline filter with filter element according to DIN 24550
Inline filter with filter element according to DIN 24550 RE 51421/07.11 Replaces: 12.10 1/16 Type 245LEN0040 to 400; 245LE0130, 0150 Size according to DIN 24550: 0040 to 0400 Additional sizes: 0130, 0150
More informationSeries TSW Sheet No J. SUCTION FILTER, horizontal tank mounted. Dimensions: mounting surface
SUCTION FILTER, horizontal tank mounted Sheet No. 1905 J Series TSW 210-310 Dimensions: type TSW 210 TSW 310 connection - 20 SAE -20 SAE A 12.09 15.47 B 11.57 14.96 C 11.42 14.76 D 8.62 12.00 E.26.30 weight
More informationBlock mounting filter, for lateral flange-mounting
Block mounting filter, for lateral flange-mounting RE 51419/2.1 1/18 Type 35PSFN4 to 1; 35PSF13, 15 Size according to DIN 2455: 4 to 1 Additional sizes: 13, 15 Nominal pressure 35 bar [579 psi] Port up
More informationLS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm
Suction Filters LS 025 LS 035 In-line mounting Connection up to G¾ / -2 SAE Nominal flow rate up to 33 l/min / 8.7 gpm Description Application To be installed in the suction line of the pumps of hydraulic
More informationOVERVIEW OF RESERVOIR ACCESSORIES
OVERVIEW OF RESERVOIR ACCESSORIES Reservoir Accessories The reservoir of a hydraulic system can be a significant source of contamination. At the same time, the reservoir is an ideal location for correcting
More informationFMP IN-LINE FILTER SERIES. Maximum working pressure 250 bar. Flow rate to 500 l/min
INLIN FILTR Maximum working pressure 0 bar Flow rate to 00 l/min R.F. Filter Symbol without bypass Filter Symbol with Reverse Flow R.F. Filter Symbol with bypass Filter Symbol with bypass & Reverse Flow
More informationProcess Inline Filter Medium / High Pressure PFM / PFH
Process Inline Filter Medium / High Pressure PFM / PFH PFx-0 PFx-1 PFx-2 PFx-3 Specifications Connection: G 1 Q S max: 8 m 3 /h p S max: 100 bar Filtration ratings: 1 2000 µm 1. GENERAL Product description
More informationBlock mounting filter, for vertical flange-mounting
Block mounting filter, for vertical flange-mounting RE 51417/12.1 Replaces: 7.1 1/18 Type 45PBFN4 to 1; 45PBF13, 15 Size according to DIN 2455: 4 to 1 Additional sizes: 13, 15 Nominal pressure 45 bar [653
More informationInline filter with filter element according to DIN 24550
Inline filter with filter element according to DIN 24550 RE 51422/07.11 Replaces: 12.10 1/18 Type 350LEN0040 to 1000; 350LE0130, 0150 Size according to DIN 24550: 0040 to 1000 Additional sizes: 0130, 0150
More information