FMP IN-LINE FILTER SERIES. Maximum working pressure 250 bar. Flow rate to 500 l/min

Size: px
Start display at page:

Download "FMP IN-LINE FILTER SERIES. Maximum working pressure 250 bar. Flow rate to 500 l/min"

Transcription

1 INLIN FILTR Maximum working pressure 0 bar Flow rate to 00 l/min

2 R.F. Filter Symbol without bypass Filter Symbol with Reverse Flow R.F. Filter Symbol with bypass Filter Symbol with bypass & Reverse Flow Check Valve Filter Symbol with Check Valve Check Valve Filter Symbol with bypass & Check Valve FMPseries filters are designed for pressure line applications and are suitable for inline installation. This completely new series of filters has been developed to satisfy the medium working pressure sector of the pressure filter market. Continued research and development on both the filter bodies and the filter elements has resulted in a product line featuring a compact light weight housing combined with a high filtration efficiency. The transverse bypass valve is a standard feature with this range of product. (Non bypass for servo applications is also available). complete line of pressure differential visual and electrical indicators are available with this series of filters. FMP series filters are available with Reverse Flow Valve. Flow rates restricted for reverse flow and check valve applications. FMP series are specifically designed for mobile, agricultural and industrial applications. Internal check valve option This series of filters can be supplied with an internal check valve. The valve eliminates the need for an externally fitted valve. Installing this valve, will prevent excessive fluid loss when changing elements and reduce air Visual lectrical Indicator Cast Iron Head Seals lectrical Indicator Visual Indicator Filter element Steel Bowl CTC FMP 00 UK

3 Technical data FMP Filter body (Material) Head: Cast iron Bowl: Steel : Brass Reverse Flow : Steel (Only for 0 series) Check valve : Steel Pressure filter body Working pressure: 0 bar ( MPa) Test pressure: 0 bar ( MPa) Burst pressure: 70 bar (7 MPa) Fatigue test: cycles with pressure impulses from 0 to 0 bar ( MPa) Working Temperature from C to + 0 C setting 6 bar ±0% Other pressure settings available. Filter elements Collapse pressure Microfibre elements NR series: 0 bar Microfibre elements HS series: 0 bar Stainless square wire mesh M series: 0 bar Filtration outside inside. Seals Standard BunaN series Viton optional V series PDM optional series Compatibility with fluids Body, compatible for use with: Mineral oil according to ISO 94 waterbased emulsionssynthetic fluids water glycol. Filter elements, compatible for use with mineral oil according to ISO 94, synthetic fluids, waterbased emulsions and waterglycol. For other fluids, please consult our sales network organisation. Seals in Nitrile (BunaN) series, compatible with: Mineral oil according to ISO 94 waterbased emulsionswater glycol. Seals in Viton V series, compatible with: Synthetic fluids type HSHFDRHFDSHFDU Weights (Kg.) Lengths 4 FMP 06,9 4,,7 FMP 7, 9,4,0 FMP 0,7 4,7 0,7,7 Port connections FMP 06 See page 6 FMP See page 7 FMP 0 See page 8 MP filter elements, conform to the following ISO standard: ISO 94 Verification of collapse/burst resistence. ISO 94 Verification of fabrication integrity and determination of the first bubble point. ISO 94 Verification of material Compatibility with fluids. ISO 7 Method for end load test. ISO 74 Verification of flow fatigue characteristics. ISO 968 valuation of pressure drop versus flow characteristics. ISO 6889 Multipass method for evaluating filtration performance. Filter area Filter element type NR p 0 bar HP06 HP HP0 HS p 0 bar HP06 HP HP0 M p 0 bar HP06 HP HP0 lectrical indicators Supply voltage 0/60 Hz (V) Vca ( ) Vca 0 ( ) Vcc 0 (=) Vcc (=) Vcc 0 (=) Connector DIN Values in cm Resistive load () 0, 0, lectrical connection N Series K N Series Inductive load () 0,0 0,0 lectrical connection K Series Filter volume (dm ) Lengths 4 FMP 06 0, 0,40 0,60 FMP 0, 0,8,0 FMP 0,,9,80,0 N.C. N.O. N.C. N.O. 0

4 General Filter selection For a quick reference guide, refer to page 6, 7 & 8. Filter assembly pressure drop: p Total = p filter housing + p filter element Housing pressure drop: The p is proportional to the fluid density. Filter element pressure drop: The p is proportional to the kinematic viscosity. The pressure drop data of the filter elements reported in this brochure were obtained using mineral oil a kinematic viscosity of 0 mm /s. Technical data The curves were obtained using a mineral oil with a density of 0,86 kg/dm according to ISO 968. The p is proportional to the fluid density. Housing pressure drop,0,00 0,0 0, ,0,00 0,0 0, ,0,00 0,0 with check Valve * with check Valve with check Valve /4 port FMP 06 / port FMP FMP 0 /4 port /4 port port / port 0, Filter Selection Filter assembly sizing example p Total pc Filter housing pe Filter element Y Factor Q l/min = Flow rate V = Reference viscosity 0 mm /s V = Working viscosity in mm /s p Total = pc + pe pe = Y x Q x ( V/V ) Sizing xample Q = 00 l/min V = 46 mm /s Pmax = 0 bar Filtration = 6 µm absolute p Total max =, bar (recommendation) Collapse pressure filter element pmax 0 bar pc = 0,47 bar (* see FMP diagramm) pe = 0,00688 x 00 x ( 46/0 ) = 0,98 bar p Total = 0,47 + 0,98 =,4 bar Filter selected FMP length with 6 filter element HP 06 lement Technical data For application with kinematic viscosity s other than 0 mm/s see above example Y factor for the pressure drop of the individual filter elements Filter element Y Factor Filter lement N series 0,0800 0, ,066 0, ,0074 0,0086 0, ,064 0,06 0,0888 0,007 0,00 0,0000 0,0889 0,0088 0, ,0097 0,0008 Y Factor Filter lement H series 0,068 0,0860 0, ,0667 0,048 0,040 0,0667 0, , , ,00 0, ,0086 0, ,00467 Filter Lengths 4

5 HP lement technical data For application with kinematic viscosity s other than 0 mm/s see example page 4 Y factor for the pressure drop of the individual filter elements Filter element Filter element Y Factor Filter lement N series 0,00 0, , , , , ,04 0,0067 0, , ,00 0,000 0, ,006 0,0088 0,0066 0,004 0,0004 Y Factor Filter lement N series 0, ,0097 0,000 0,007 0,004 0,0004 0, ,008 0,0074 0, , , ,0070 0,004 0,000 0, , ,0006 0,00 0,0077 0, , ,0006 0,00047 Y Factor Filter lement H series 0,0967 0,0 0,0000 0,0476 0,0096 0,0486 0,0048 0, , , , , , , ,00077 Filter Lengths HP 0 lement technical data Y Factor Filter lement H series 0,0000 0,090 0, , ,000 0, ,004 0,0008 0,0089 0,007 0,004 0,004 0, , ,0078 0,007 0,0074 0, , ,0004 Filter Lengths 4 Valves pressure drop 0,0,00 0,0 FMP 0, ,0,00 0, Reverse Flow valve pressure drop FMP 06 FMP FMP 0 FMP FMP 0 0, Reverse Flow Forward Flow

6 FMP 06 Indicator options Led 4, /F /F Z V N K 8 8 Filter selectionquick reference guide The following filter sizing recommendations are based on using a mineral oil 0 mm /s (C sts) with a maximum filter assembly (housing & filter element) pressure drop of, bar. Filter Flow rate Flow rate element l/min l/min Port Filter type N Series H Series Size Length H H Ø 68 Indicator port and bypass valve may be interchanged / / standard option side B 46 Mounting holes / / alternative option side C Thread connections Connection / BSP / NPT /4 BSP /4 NPT S 8 (/4 6 UNF) S ( /6 UN) Mounting Holes ( mm) M8 /6 UNC M8 /6 UNC /6 UNC /6 UNC 6

7 FMP Indicator options Led 4, /F /F Z V N K 04 Filter selectionquick reference guide The following filter sizing recommendations are based on 8 using a mineral oil 0 mm /s(c sts) with a maximum filter assembly (housing & filter element) pressure drop of, Filter Flow rate Flow rate element l/min l/min Port Filter type N Series H Series Size Length H H Ø 78 Indicator port and bypass valve may be interchanged / standard option side B Mounting holes Thread connections 40,6 alternative option side C Flange connections Connection /4 BSP /4 NPT BSP NPT S ( /6 UN) S 6 ( /6 UN) Mounting Holes M0 /8 UNC M0 /8 UNC /8 UNC /8 UNC Flange connections B C D Connection B /4 S000 psi/m 47.6 /4 S000 psi/unc 47.6 S000 psi/m.7 S000 psi/unc.7 C D ( mm) M0 M0 /8 UNC /8 UNC M0 M0 /8 UNC /8 UNC 7

8 FMP 0 Indicator options Led 4, /F /F Z V N K Filter selectionquick reference guide The following filter sizing recommendations are based on C using a mineral oil 0 mm /s(c sts) with a maximum filter assembly (housing & filter element) pressure drop of B D Filter Flow rate Flow rate element l/min l/min Port Filter type N Series H Series Size Length H H FMP 0/4 Only / Ø Ø / 84 /F Mounting holes / Indicator port standard option side B alternative option side C / 4 6 Thread connections Flange connections Connection /4 BSP /4 NPT / BSP / NPT S 0 ( /8 UN) S 4 ( 7/8 UN) Mounting Holes ( mm) M / UNC M / UNC / UNC / UNC Connection /4 S000 psi/m /4 S000 psi/unc / S000 psi/m / S000 psi/unc B C 0.8 D M0 ( mm) M 0.8 7/6 UNC / UNC.7.7 M / UNC M / UNC 8

9 Multipass method for evaluating Filtration performance according to ISO ISO MTD test dust Multipass method for evaluating Filtration performance according to ISO 47. CFTD test dust Dimensions for ß values Dimensions for ß values 00 fficiency in % 0% 90% 98,70% 99% 99,0% 99,90% fficiency in % 99,0% lements media (µm ) µm 0 < < < <,0 4, 0 µm 06 < < 4, 4,.07 6, 06 6 µm 6 0 <6 <6 6, 6,4 7, 9,0 0 0 µm 0 6 <7 <7 0,4 0,97,,9 6 6 µm 6 <9,4,8 6,0 7,46 9, µm The data are reported to a value of final p equal to 6 bar Characteristics of the filter element with nominal filtration M / T series Square wire mesh filtration degree is defined in microns by the maximum diameter of a sphere corresponding to the mesh size. Hydraulic System Component Cleanliness Levels System component Typical Cleanliness Specification Servo valve Proportional valve Variable pump Cartridge valve Fixed piston pump Vane pump Pressure/flow control valve Solenoid valve ISO cleanliness NS cleanliness Recommended absolute micron size /0/7 //8 4//9 //0 6/4/ 7// 8/6/ 9/7/4 0/8/ micron 6 micron 0 micron >0 bsolute filter elements have been tested by the following independent institutes. 9

10 Notes 0 Data held in this publication is given only for indicative purposes, MP Filtri reserves to introduce modifications to described items for technical or commercial reasons. Copyright reserved.

11 Ordering information FMP Filter assembly FMP Filter element HP xample: FMP 06 B G 0 N P0 / V xample: HP06 0 N P0 Size 06 FMP 06 FMP 0 FMP 0 Filter Length Valve 4 (Only for 0 series) S B C D 4 Seals Without bypass With bypass (standard option) With bypass (alternative option) With bypass B & Check valve V With reverse flow * (Only for 0 series) R With reverse flow + bypass * (Only for 0 series) T With Check valve * *Restricted Flow Rate Port options TYP 06 0 G / BSP /4 BSP /4 BSP G /4 BSP BSP / BSP G / NPT /4 NPT /4 NPT G4 /4 NPT NPT / NPT G S 8 (/4 6 UNF) S ( /6 UN) S 0 ( /8 UN) G6 S ( /6 UN) S 6 ( /6 UN) S 4 ( 7/8 UN) F /4 S 000 PSI/M /4 S 000 PSI/M F S 000 PSI/M / S 000 PSI/M F /4 S 000 PSI/UNC /4 S 000 PSI/UNC F4 S 000 PSI/UNC / S 000 PSI/UNC 6 Filter elements 0 Inorganic microfibre µm 06 Inorganic microfibre 6 µm 0 Inorganic microfibre 0 µm ßx (c) Inorganic microfibre 6 µm See page 9 Inorganic microfibre µm Square wire mesh 7 Collapse pressure series N 0 bar H 0 bar R 0 bar (Filter with Reverse Flow) S 0 bar (Filter with Reverse Flow) BunaN 8 Filter assembly type V Viton P0 MP Filtri standard PDM Pxx Customer request 9 Filter condition indicator Z7 Visual (Popup) bar N7 lectrical bar K7* Visualelectrical bar Z8 V7 V8 Visual (Popup) 7 bar Visual bar Visual 7 bar N8 7 8 lectrical 7 bar Visualelectrical bar Visualelectrical 7 bar K8* Visualelectrical 7 bar 4 Volt *{ 0 Volt 0 Volt MP Filtri Filtration products will only be guaranteed if original MP Filtri replacement elements and spares are used

12 Head Quarter : MP FILTRI S.p.. Italy Via Matteotti, 0060 Pessano con Bornago (Milano) Italy Tel /970. Fax ++9.0/ sales@mpfiltri.com GRT BRITIN MP FILTRI U.K. Ltd. Bourton Industrial Park Bourton on the Water Gloucestershire GL4 HQ UK Phone: 048 Fax: sales@mpfiltri.co.uk GRMNY MP FILTRI D GmbH m Wasserturm D666 Heusweiler/Holz Phone: 06806/800 Fax: 06806/808 mpfiltrink@aol.com FRNC MP FILTRI FRNC B.P. 060 Trevoux Cedex Tel: Telefax: mpfiltrifrance@wanadoo.fr US MP FILTRI US Inc. 0 Quaker Pointe Drive Quakertown, P 89 Phone: 900 Fax: mpusasales@aol.com CND MP FILTRI CND Inc. 0 Jacob Keffer Parkway Concord, Ontario Canada L4K 4W Phone: Fax: mail@mpfiltricanada.com

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

A complete line of pressure differential visual and electrical indicators are available with this series of filters. D e s c r i p t i o n FHP series filters are designed for high pressure line applications and are suitable for in-line installation. Continued research and development on both the filter bodies and the

More information

MPF filters within this range are suitable for flow rates up to 750 l/min.

MPF filters within this range are suitable for flow rates up to 750 l/min. D e s c r i p t i o n MPF series filters are designed for return lines, and are installed semi-immersed in a reservoir. Continued Research & Development on both the filter bodies and the filter elements

More information

SERIES FRI. Maximum working pressure 20 bar Flow rate to 1200 l/min. s.p.a

SERIES FRI. Maximum working pressure 20 bar Flow rate to 1200 l/min. s.p.a New Headquarters : MP FILTRI S.p.. Italy Via 1 Maggio, n. 3 Pessano con Bornago (Milano) Italy Tel. +39./973.1 Fax +39./9741497-974188 email: sales@mpfiltri.com http://www.mpfiltri.com GRT BRITIN MP FILTRI

More information

SERIES SF2-250 SUCTION FILTER. Flow rate to 45 gpm

SERIES SF2-250 SUCTION FILTER. Flow rate to 45 gpm SERIES SF2-250 SUCTION FILTER Flow rate to 45 gpm D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows

More information

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from

More information

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

A complete line of pressure differential visual and electrical indicators are available with this series of filters. D e s c r i p t i o n FHB series filters are designed for pressure line applications where manifold mounting is a specific requirement. The manifold type filters are designed to integrate onto manifold

More information

SERIES SF2-500 SUCTION FILTER. Flow rates to 225 gpm

SERIES SF2-500 SUCTION FILTER. Flow rates to 225 gpm SERIES SF2-5 SUTION FILTER Flow rates to 225 gpm D e s c r i p t i o n 5 The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 225 gpm and filtration from

More information

MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min

MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN Maximum working pressure 12 bar Flow rates to 3 l/min D e s c r i p t i o n MPS/MST The spin-on filter series is a complete product range suitable, for

More information

SPIN-ON FILTER - LOW PRESSURE LINE

SPIN-ON FILTER - LOW PRESSURE LINE SERIES MSH SPIN-ON FILTER - LOW PRESSURE LINE Maximum working pressure 5 psi Flow rate to 8 GPM D e s c r i p t i o n MSH working pressure of 5 psi, with a peak pressure This filter MSH series utilises

More information

SERIES. Maximum pressure 110 bar

SERIES. Maximum pressure 110 bar SERIES Maximum pressure 0 bar F l o w r a t e s t o 9 5 l / m i n Technical data FMP 09 Compatibility Filter housing (Materials) Head: nodized aluminium Housing: nodized aluminium Bypass valve: Steel Pressure

More information

NEW. High Pressure filters. FMM 150 series. Maximum pressure up to 420 bar - Flow rate up to 250 l/min

NEW. High Pressure filters. FMM 150 series. Maximum pressure up to 420 bar - Flow rate up to 250 l/min NEW High Pressure filters FMM 50 series Maximum pressure up to 0 bar - Flow rate up to 50 l/min PASSION TO PERFORM FILTER SIZING THE CORRECT FILTER SIZING HAVE TO BE BASED ON THE TOTAL PRESSURE DROP DEPENDING

More information

Working pressure. 350 bar. Style B Series FHD 051. Series FHD 325/332 D.I. D.I. D.I. A A

Working pressure. 350 bar. Style B Series FHD 051. Series FHD 325/332 D.I. D.I. D.I. A A 98 FD SRIS FD Working pressure 350 bar Style S Style Series FD 05 Style Series FD 35/33 D.I. D.I. D.I. 99 Technical data body (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical

More information

D e s c r i p t i o n

D e s c r i p t i o n D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from

More information

FMM bar. Working pressure. Style T. Style D. Style S. Style B D.I. D.I. D.I. D.I.

FMM bar. Working pressure. Style T. Style D. Style S. Style B D.I. D.I. D.I. D.I. 30 FMM 050 SRIS FMM 050 Working pressure 0 bar Style S Style Style T Style D 3 3 Technical data Filter body (Materials) Head: Cast iron (chemical heat treatment) Housing: Steel (chemical heat treatment)

More information

Flow rates to 500 l/min

Flow rates to 500 l/min FF 5 Filter housing in according to SE J066 for F filter elements Maximum pressure 50 bar Flow rates to 500 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing:

More information

D e s c r i p t i o n

D e s c r i p t i o n e s c r i p t i o n MPH and MPI series filters are designed for returnline applications and provide various installation applications. The filters are installed semiimmersed (MPH) or totally immersed into

More information

High Pressure fi lters. FHP series. Maximum pressure up to 420 bar - Flow rate up to 750 l/min. High Pressure fi lters

High Pressure fi lters. FHP series. Maximum pressure up to 420 bar - Flow rate up to 750 l/min. High Pressure fi lters igh Pressure fi lters FP series Maximum pressure up to bar Flow rate up to 7 l/min igh Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending

More information

FHF325 series. Filter housing according to SAE J2066 for HF4 filter elements. High Pressure fi lters

FHF325 series. Filter housing according to SAE J2066 for HF4 filter elements. High Pressure fi lters High Pressure fi lters FHF5 series Maximum pressure up to 50 bar Flow rate up to 500 l/min housing according to SAE J066 for HF filter s 95 High Pressure fi lters FILTER SIZING The correct filter sizing

More information

FHA 051 Working pressure 6000 psi

FHA 051 Working pressure 6000 psi 6 SRIS Working pressure 6000 psi Style S Style Style T Style D Style V Style Z D.I. 7 8 Technical data Filter body (Materials) Head: Steel (chemical heat treatment) Housing: Steel (chemical heat treatment)

More information

DIN Filter element according to DIN Low & Medium Pressure filters. Maximum pressure up to 60 bar - Flow rate up to 330 l/min

DIN Filter element according to DIN Low & Medium Pressure filters. Maximum pressure up to 60 bar - Flow rate up to 330 l/min Low & Medium Pressure filters & series Maximum pressure up to 60 bar Flow rate up to 0 l/min DIN 550 09 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable

More information

525 Stainless steel high pressure filters. FZP series. Maximum pressure up to 420 bar. Stainless steel high pressure fi lters

525 Stainless steel high pressure filters. FZP series. Maximum pressure up to 420 bar. Stainless steel high pressure fi lters Stainless steel high pressure fi lters FZP series Maximum pressure up to 0 bar 55 Stainless steel high pressure filters FILTER SIZING The correct filter sizing have to be based on the variable pressure

More information

LDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min

LDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min Low & Medium Pressure filters LDP & series Maximum working pressure up to 6 MPa (60 bar) Flow rate up to 0 l/min 7 Low & Medium Pressure filters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE

More information

RF2 Maximum pressure 20 bar F l o w r a t e s t o l / m i n

RF2 Maximum pressure 20 bar F l o w r a t e s t o l / m i n RF2 96 Maximum pressure 20 bar F l o w r a t e s t o 4 5 5 l / m i n Filter housing (Materials) Filter body: luminium over: Nylon Valve: Nylon - Steel nti-emptying valve: Steel Pressure Working pressure:

More information

MPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n

MPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n MPH Maximum pressure bar F l o w r a t e s t o l / m i n 6 echnical data housing (Materials) Head: luminium: MPH ---- nodised luminium: MPH 6-8 Painted luminium: MPH 66 Cover: Nylon: MPH --- luminium:

More information

MPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n

MPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n MPH Maximum pressure bar F l o w r a t e s t o l / m i n 6 echnical data Filter housing (Materials) Head: luminium: MPH ---- nodised luminium: MPH 6-8 Painted luminium: MPH 66 Cover: Nylon: MPH --- luminium:

More information

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters Return fi lters series Maximum pressure up to bar - Flow rate up to 15 l/min 193 Return fi lters GENERAL INFORMATION Technical data Return filter Maximum pressure up to bar - Flow rate up to 15 l/min Filter

More information

Flow rates to 3000 l/min

Flow rates to 3000 l/min MPH Maximum pressure bar Flow rates to l/min echnical data housing (Materials) Head: luminium: MPH nodised luminium: MPH 68 Painted luminium: MPH 66 Cover: Nylon: MPH luminium: MPH nodised luminium: MPH

More information

LMP series. 305 Low & Medium Pressure filters MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min

LMP series. 305 Low & Medium Pressure filters MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min Low & Medium Pressure fi lters LMP - series Maximum pressure up to 8 bar - Flow rate up to l/min 5 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable

More information

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04 Inline Filter MFM Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS 400-15 / steel 1. TECHNICAL SPECIFICATIONS 1.1. FILTER HOUSING Construction The inline filter consists of a filter

More information

Fluid Cooling Industrial COLW Series

Fluid Cooling Industrial COLW Series Fluid Cooling Industrial COLW Series 0916 COPPER & STEEL CONSTRUCTION Performance Notes Ideal for independent cooling and filtering of system oils Utilizes a high efficient EK series shell & tube (finned

More information

Return Line Filter RF

Return Line Filter RF HYDAC return line filters type RF are designed to be mounted directly on tank tops. Inline mounting is also possible. Return Line Filter RF Flow rates up to 5, l/min Pressure range up to 25 bar Material:

More information

MPT SERIES RETURN FILTER

MPT SERIES RETURN FILTER MPT SRIS The series of filters MPT has specifically been designed for use on mobile power packs for industrial, mobil and lift truk applications. The MPT filter range is suitable for flow rates up to 50

More information

LMP series

LMP series Low & Medium Pressure fi lters LMP 95-95-95 series Maximum working pressure up to.5 MPa (5 bar) - Flow rate up to 000 l/min 7 Low & Medium Pressure filters Introduction FILTER SIZG DEX CALCULATION CORRECTIVE

More information

HD 049 HD 069 HD 172 HD 319 HD 419 HD 619 Operating pressure up to 630 bar Nominal flow rate up to 450 l/min

HD 049 HD 069 HD 172 HD 319 HD 419 HD 619 Operating pressure up to 630 bar Nominal flow rate up to 450 l/min High Pressure ilter Kits H 9 H 9 H 7 H 9 H 9 H 9 Operating pressure up to bar Nominal flow rate up to l/min escription Application In the high pressure circuits of hydraulic systems. Performance features

More information

Low Pressure Filter Spin-on Cartridges HC/OC

Low Pressure Filter Spin-on Cartridges HC/OC Low Pressure Filter Spinon Cartridges HC/OC Nominal pressure 10/16/25 bar (140/230/360 psi), nominal size up to 160 1. Features High performance filters for modern hydraulic systems Modular design Compact

More information

Return / Suction fi lters In-line. LMP 124 series MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min. Return / Suction fi lters

Return / Suction fi lters In-line. LMP 124 series MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min. Return / Suction fi lters Return / Suction fi lters Inline LMP series Maximum pressure up to 8 bar Flow rate up to l/min 9 Return / Suction fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure

More information

Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 500 l/min Pressure range up to 315 bar Material: SG Iron/ADI, Steel

Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 500 l/min Pressure range up to 315 bar Material: SG Iron/ADI, Steel Manifold Mounted, Rear Flanged Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 5 l/min Pressure range up to 35 bar Material: SG Iron/ADI, Steel . DESCRIPTION.. FILTER HOUSING

More information

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar RFL inline filters are designed for inline mounting in hydraulic and lubrication systems. Inline Filter RFL Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar * For larger flow rates,

More information

THE IMPORTANCE OF AN EFFICIENT FILTRATION

THE IMPORTANCE OF AN EFFICIENT FILTRATION In line high pressure filters HF 745 / HF 748 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the

More information

Duplex Pressure Filters

Duplex Pressure Filters Duplex Pressure Filters Series DFDK Ball Valve Selector Pressures to 45 psi Flows to 9 gpm APPLICATIONS HYDAC DFDK Duplex Filters are ideal for use on hydraulic test equipment, robots, or other critical

More information

Low pressure filter Spin-on cartridges PX

Low pressure filter Spin-on cartridges PX MAHLE Industrialfiltration is now Filtration Group. For more information, visit www.filtrationgroup.com Low pressure filter Spin-on cartridges PX Nominal pressure 16/10 bar (230/140 psi), nominal size

More information

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) HYDRAULIC FILTRATION Medium pressure, in line spin-on filters Technical Information Pressure: Max working (acc. to NFPA T 3.10.17): FA-4-1x: 34,5 bar (500 psi) FA-4-21: 24 bar (348 psi) Burst (acc. to

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS HIGH PRESSURE FILTERS Series DF & LF Pressures to 6 PSI Flows to 18 GPM APPLICATION HYDAC DF & LF In-line High Pressure Filters are designed for use on hydraulic power units, machine tools, plastics machinery,

More information

In line high pressure filters. HF 725 series

In line high pressure filters. HF 725 series In line high pressure filters HF 725 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the fluid.

More information

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar Nominal flow rate up to l/min

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar Nominal flow rate up to l/min High Pressure Filters Worldline HD 79 HD 99 In-line mounting Operating pressure up to bar Nominal flow rate up to. l/min Description Application In the high pressure circuits of hydraulic systems. Performance

More information

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane HYDRAULIC FILTRATION Spin-on, tank top return filters Technical Information Pressure: Max working 12 bar (175 psi) (acc. to NFPA T 3.10.17) Burst 20 bar (290 psi) (acc. to NFPA T 3.10.17) Connection Ports:

More information

FPK 02 AP280. Pressure Line High Pressure Filters In-Line up to 420 bar. Mix&Match to Get What You Need

FPK 02 AP280. Pressure Line High Pressure Filters In-Line up to 420 bar. Mix&Match to Get What You Need FPK 02 AP280 Pressure Line High Pressure Filters In-Line up to 420 bar Mix&Match to Get What You Need Donaldson's Mix&Match system provides the great performance and functional advantages of custom-engineered

More information

MATERIALS CARTRIDGES PRESSURES VALUES TESTS CARRIED OUT ON FILTER ELEMENTS

MATERIALS CARTRIDGES PRESSURES VALUES TESTS CARRIED OUT ON FILTER ELEMENTS 1 OIL FILTER DESCRIPTION Many years of in-field experience have shown the necessity of more and more efficient controls on the contamination level of hydraulic fluids and fuels. With this goal uppermost

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS APPLICATION HIGH PRESSURE FILTERS For Manifold Block Mounting Series DF...P Pressures to 45 psi Flows to 18 gpm HYDAC DF...P High Pressure Filters are designed to be mounted directly onto the manifold

More information

High Pressure Filters HD 044 HD 064. Flangeable Operating pressure up to 500 bar Nominal flow rate up to 105 l/min e

High Pressure Filters HD 044 HD 064. Flangeable Operating pressure up to 500 bar Nominal flow rate up to 105 l/min e High Pressure Filters HD HD Flangeable Operating pressure up to bar Nominal flow rate up to l/min.3-e Description Application In the high pressure circuits of hydraulic systems. Performance features Protection

More information

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar / 9137 psi Nominal flow rate up to l/min / gpm

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar / 9137 psi Nominal flow rate up to l/min / gpm High Pressure Filters Worldline 4 HD 79 HD 99 In-line mounting Operating pressure up to bar / 97 psi Nominal flow rate up to. l/min / 4. gpm Description Application In the high pressure circuits of hydraulic

More information

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T ) HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T 3.10.5.1) Burst 840 bar (12200 psi) (acc. to NFPA T 3.10.5.1) Housing

More information

Inline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01.

Inline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01. Change-Over Inline Filter RFLD Cast Version Flow Rates up to 3 l/min* Pressure Range 25/4/64 bar With Ball Change-Over Valve * For higher flow rates, please refer to brochure RFLD Welded Version E 7.9.2/.4

More information

In line high pressure filters. HF 735 series

In line high pressure filters. HF 735 series In line high pressure filters HF 735 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the fluid.

More information

Filtering elements differential collapsing pressure tested in compliance with ISO 2941:

Filtering elements differential collapsing pressure tested in compliance with ISO 2941: DESCRIPTION Many years of in-field experience have shown the necessity of more and more efficient controls on the contamination level of hydraulic fluids and fuels. With this goal uppermost in its mind,

More information

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181 Common HYDRAULIC FILTRATION Side wall mounting suction filters Technical Information Connection Ports: 1-1 1/4-1 1/2 BSP (other thread options on request) 1 1/2 SAE J518-3000/M12 Housing Materials: Cover:

More information

Off-line Oil Filter Module Pi 8400

Off-line Oil Filter Module Pi 8400 Off-line Oil Filter Module Pi 8400 Volume flow l/min 1. Features Compact, ready-to connect oil filter module for modern hydraulic and lubrication systems Low noise internal gear pump Minimum loss of performance

More information

High Pressure Filters Worldline 400 HD 790 HD 990. In-line mounting Operating pressure up to 9137 psi Nominal flow rate up to gpm. 40.

High Pressure Filters Worldline 400 HD 790 HD 990. In-line mounting Operating pressure up to 9137 psi Nominal flow rate up to gpm. 40. High Pressure Filters Worldline 4 HD 79 HD 99 In-line mounting Operating pressure up to 97 psi Nominal flow rate up to 64. gpm 4.9-us Description Application In the high pressure circuits of hydraulic

More information

Return / Suction fi lters Tank mounted. MRSX series. Maximum pressure up to 10 bar - Flow rate up to 300 l/min. Return / Suction fi lters

Return / Suction fi lters Tank mounted. MRSX series. Maximum pressure up to 10 bar - Flow rate up to 300 l/min. Return / Suction fi lters Return / Suction fi lters mounted MRSX series Maximum pressure up to bar Flow rate up to l/min 9 Return / Suction fi lters FILTER SIZG The correct filter sizing have to be based on the variable pressure

More information

Low Pressure Filter Spin-on Cartridges HC/OC

Low Pressure Filter Spin-on Cartridges HC/OC Low Pressure Filter Spin-on Cartridges HC/OC Nominal pressure 10/16/ bar (140/230/360 psi), nominal size up to 160 1. Features High performance filters for modern hydraulic systems Modular design Compact

More information

Duplex Filter Pi Features. Nominal pressure 25 bar (360 psi), nominal size 800 and 1400

Duplex Filter Pi Features. Nominal pressure 25 bar (360 psi), nominal size 800 and 1400 Duplex Filter Pi 232 Nominal pressure 25 bar (360 psi), nominal size 800 and 1400 1. Features Duplex filter for gear boxes, lubrication and hydraulic systems Modular system Compact design Weight optimized

More information

PLEASE SEE FOLLOWING PAGES FOR FURTHER DETAILS

PLEASE SEE FOLLOWING PAGES FOR FURTHER DETAILS Help? RKR HIH RSSUR FILTRS Types 4- and 4-2 Designed for systems operating up to 44 bar. Two filter sizes handle flows up to 560 l/min. Minimum static burst: 240 bar. /4 BSF threads. Filter down to microns

More information

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) HYDRAULIC FILTRATION Tank top return filters Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.1..1) Burst 16 bar (232 psi) (acc. to NFPA T 3.1..1) Housing Connection Ports:

More information

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm Suction Filters LS 025 LS 035 In-line mounting Connection up to G¾ / -2 SAE Nominal flow rate up to 33 l/min / 8.7 gpm Description Application To be installed in the suction line of the pumps of hydraulic

More information

Low Pressure Filter Pi 2300

Low Pressure Filter Pi 2300 Low Pressure Filter Pi 2300 Nominal pressure 25/40 bar (360/570 psi), nominal size up to 1 Filter elements according DIN 24550 1. Features High performance filters for modern hydraulic systems Provided

More information

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi) HYDRAULIC FILTRATION F8-D1 series In line medium pressure filters Technical Information Housing Pressure: Max working F8 D1x port size 1/ & 3/4 : 4 bar (6 psi) F8 D1x port size 1 : 3 bar (4 psi) F8 D14x:

More information

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request) HYDRAULIC FILTRATION Return filters, tank top mounting, inside-to-outside filtration Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.10.5.1) Burst 16 bar (232 psi) (acc. to

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS APPLICATION HIGH PRESSURE FILTERS For Manifold Block Mounting Series DF...P Pressures to 4 psi Flows to 18 gpm HYDAC DF...P High Pressure Filters are designed to be mounted directly onto the manifold block

More information

ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min

ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min Suction Filters ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min Description Application To be installed in the suction line of the pumps of hydraulic systems resp. upstream

More information

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request) HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1.5.1): F1-XD4/63/1: 1 bar (15 psi) F1-XD16/25/4: 8 bar (12 psi) Housing Burst (acc. to

More information

High Pressure Filter Kits HD 049 HD 069 HD 172 HD 319 HD 419 HD 619. Operating pressure up to 9137 psi Nominal flow rate up to gpm. 40.

High Pressure Filter Kits HD 049 HD 069 HD 172 HD 319 HD 419 HD 619. Operating pressure up to 9137 psi Nominal flow rate up to gpm. 40. High Pressure ilter Kits H 9 H 9 H 7 H 9 H 9 H 9 Operating pressure up to 97 psi Nominal flow rate up to 8.9 gpm.9-us escription Application In the high pressure circuits of hydraulic systems. Performance

More information

Oil Filter Module Pi 8300

Oil Filter Module Pi 8300 Oil Filter Module Pi 8300 Volume flow 1 und 220 l/min 1. Features Compact, ready-to connect oil filter module for modern hydraulic and lubrication systems Low noise internal gear pump Minimum loss of performance

More information

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF up to 600 l/min, up to 315 bar 60 110 140 160 240 280 330 500 660 1.X 660 2.X 990 1320 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING

More information

In line high pressure filters. HF HF 761 series

In line high pressure filters. HF HF 761 series In line high pressure filters HF 76 - HF 761 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the

More information

SPIN-ON FILTERS & ELEMENTS

SPIN-ON FILTERS & ELEMENTS ABSOLUTE RATED (BETA SPIN ) & NOMINAL RATED SPIN-ON FILTERS & ELEMENTS Single and Twin Element Models Pressures to 20 psi Flows to 120 gpm APPLICATION HYDAC Spin-On Filters are for filtration of hydraulic

More information

Oil Filter Module Pi 8300

Oil Filter Module Pi 8300 Oil Filter Module Pi 8300 Volume flow 1 und 220 l/min 1. Features Compact, ready-to connect oil filter module for modern hydraulic and lubrication systems Low noise internal gear pump Minimum loss of performance

More information

Mobile Filter Units Pi 8100

Mobile Filter Units Pi 8100 Mobile Filter Units Pi 81 Flow rates 27 and 55 l/min 1. Features High performance filters for modern hydraulic systems Mobile bypass filtration for hydraulic and lubricating systems System and container

More information

HIGH PRESSURE FILTERS Series HF2P

HIGH PRESSURE FILTERS Series HF2P HIGH PRESSURE FILTERS Series HF2P Pressures to 3000 psi Flows to 25 GPM Port Size 3/4 APPLICATION HYDAC HF2 Inline High- Pressure Filters are designed for use on hydraulic power units, machine tools, plastics,

More information

High Pressure Filter Pi 4230

High Pressure Filter Pi 4230 High Pressure Filter 4230 Nominal pressure 315 bar (4570 psi), nominal size 160 to 400 according DIN 24550 1. Features High performance filters for modern hydraulic systems Modular system Compact design

More information

Return Line Filter HF4R up to 450 l/min, up to 10 bar

Return Line Filter HF4R up to 450 l/min, up to 10 bar Return Line Filter HF4R up to 450 l/min, up to 10 bar 9" 18" 27" 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed in accordance with international regulations.

More information

High Pressure Filter Pi 410

High Pressure Filter Pi 410 High Pressure Filter Pi 410 Nominal pressure 315 bar (4480 psi), nominal size -63 1. Features High performance filters for modern hydraulic systems Provided for valve block installation Modular system

More information

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request) HYDRAULIC FILTRATION F4-DMD series In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1..1): F4-DMD/8/11: 7 bar (11 psi) F4-DMD1/3/4: 4 bar (8 psi) Housing Burst

More information

Low Pressure Filter Pi 2000

Low Pressure Filter Pi 2000 Low Pressure Filter Pi 00 Nominal pressure 32/63 bar (460/900 psi), nominal size up to 400 according DIN 24550 1. Features.. High performance filters for modern hydraulic systems Provided for pipe installation

More information

Low Pressure Filter Pi 200

Low Pressure Filter Pi 200 Low Pressure Filter Pi 0 Nominal pressure 25/63 bar (360/910 psi), nominal size up to 450 1. Features._ High performance filters for modern hydraulic systems Provided for pipe installation Modular system

More information

High Pressure Filter Pi 4230

High Pressure Filter Pi 4230 High Pressure Filter Pi 4230 Nominal pressure 400 bar (5690 psi), nominal size 160 to 400 according DIN 24550 1. Features High performance filters for modern hydraulic systems Modular system Compact design

More information

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min Suction Filters ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min Description Application To be installed in the suction line of the pumps of hydraulic systems resp.

More information

Low Pressure Filter Pi 2000/Pi 2200

Low Pressure Filter Pi 2000/Pi 2200 Low Pressure Filter Pi 2000/Pi 2200 Nominal pressure 25 bar (360 psi), nominal size 630 up to 2000 according to DIN 24550 1 Features : HIgh performance filters for modern hydraulic systems Modular system

More information

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T 3.10.5.1) Burst 330 bar (4800 psi) (acc. to NFPA T 3.10.5.1) Housing

More information

Oil Solutions. Phone Fax Low Pressure Filter Pi 150

Oil Solutions. Phone Fax Low Pressure Filter Pi 150 Oil Solutions Phone 0421 336 009 Fax 03 9012 4332 sales@oilsolutionscomau wwwoilsolutionscomau Low Pressure Filter Pi 150 Operating pressure /25 bar, Nominal size up to 630 1 Features Efficient filters

More information

Low Pressure Filter Pi 230

Low Pressure Filter Pi 230 Low Pressure Filter Pi 230 Nominal pressure 25/40 bar, (360/570 psi), nominal size up to 1400 1. Features High performance filters for modern hydraulic systems Provided for pipe installation Modular system

More information

Duplex Filter Pi Features. Nominal pressure 10/16 bar (140/230 psi), nominal size 1250 up to 8000

Duplex Filter Pi Features. Nominal pressure 10/16 bar (140/230 psi), nominal size 1250 up to 8000 Duplex Filter Pi 281 Nominal pressure / bar (140/230 psi), nominal size 1 up to 8000 1. Features _ High performance filters for modern hydraulic systems Modular system Compact design Minimal pressure drop

More information

Line filter Pi Features. Nominal pressure 16 bar (230 psi), nominal size 400 up to 6000

Line filter Pi Features. Nominal pressure 16 bar (230 psi), nominal size 400 up to 6000 Line filter Pi 1907 Nominal pressure 16 bar (20 psi), nominal size 400 up to 1 Features _ High performance filters for modern hydraulic systems Provided for pipe installation Modular design Compact design

More information

Duplex Filter Pi Features. Nominal pressure 40 bar (570 psi), nominal size 800 and 1100

Duplex Filter Pi Features. Nominal pressure 40 bar (570 psi), nominal size 800 and 1100 Duplex Filter Pi 211 Nominal pressure 40 bar (570 psi), nominal size 800 and 1100 1. Features High performance filters for modern hydraulic systems Modular system Compact design Minimal pressure drop through

More information

Low Pressure Filter Pi 200

Low Pressure Filter Pi 200 Low Pressure Filter Pi 0 Nominal pressure 32/63 bar (460/910 psi), nominal size up to 600 1. Features._ High performance filters for modern hydraulic systems Provided for pipe installation Modular system

More information

Pressure Filter DF...K P, DF...M P, Flange Mounted

Pressure Filter DF...K P, DF...M P, Flange Mounted Pressure Filter, DF...M P, Flange Mounted up to 550 l/min, up to 260 bar DF...M P 330...1.X 160 240 280 500...1.X 660...1.X 660...2.X 990...2.X 1320...2.X 660...3.X 990...3.X 1320...3.X 1. TECHNICAL SPECIFICATIONS

More information

Hydraulic Filtration. Product Range. Low & Medium Pressure Filters. Return Filters MPFX MPTX MFBX. China United Kingdom India Canada

Hydraulic Filtration. Product Range. Low & Medium Pressure Filters. Return Filters MPFX MPTX MFBX. China United Kingdom India Canada M Y (Not LMP900-901/902-903/950-951/952-953-954) Positioned on the return line to the tank, return filters perform the task of filtering fluid and preventing particles entering the system - externally

More information

High Pressure Filter Pi 4000

High Pressure Filter Pi 4000 High Pressure Filter Pi 4000 Nominal pressure 400 bar (5690 psi), nominal size up to 400 according DIN 24550 1. Features High performance filters for modern hydraulic systems Modular system Compact design

More information

Low Pressure Filter Pi 1500

Low Pressure Filter Pi 1500 Low Pressure Filter Pi 500 Nominal pressure /5 bar (40/360 psi), nominal size up to 600 Filter elements according to DIN 4550. Features High performance filters for modern hydraulic systems Provided for

More information

Stainless Steel Pressure Filters

Stainless Steel Pressure Filters Stainless Steel Pressure Filters Inline Filters up to 26,000 PSIG up to 35 GPM Description Process Filtration MPSSF / HPSSF/ ACSSF Series The pressure filters consist of two main sections: the filter head

More information

In-Line Filters. Section Index. High FPK

In-Line Filters. Section Index. High FPK Hydraulic In-Line Filters Section Index NEW Medium Pressure Filters FMK-FM............................ FCK-LC............................. 123 HMK04 Duramax.................... 124 HMK05 Duramax....................

More information