A complete line of pressure differential visual and electrical indicators are available with this series of filters.
|
|
- Miles Mitchell
- 6 years ago
- Views:
Transcription
1
2 D e s c r i p t i o n FHP series filters are designed for high pressure line applications and are suitable for in-line installation. Continued research and development on both the filter bodies and the filter elements has resulted in a product line with excellent pressure drop characteristics combined with a high filtration efficiency. The transverse by-pass valve is a standard feature with this range of product. (Non bypass for servo applications is also available). complete line of pressure differential visual and electrical indicators are available with this series of filters. FMP series filters are available with Reverse Flow Valve. FHP series filters within this range are suitable for flow rates to 450 l/min. See page 1. FHP series are specifically designed for mobile, industrial and power pack applications. BYPSS RE BLNKING PLUG BYPSS VLVE New absolute filter elements independently tested in the following Institutes: DIFFERENTIL INDICTORS ELECTRICL CST IRON HED O-RING + RETINING RING VISUL - ELECTRICL O-RING VISUL UNI EN ISO 9001 N 07/98 HIGH EFFICIENCY ELEMENT WITH HIGH DIRT HOLDING CPCITY INDICTOR OPTIONS STEEL BOWL FHP 05020/6.99/UK Reply.99/UK 2
3 MP Filtri - Filtration technology Filter element: Filter element material End caps: Steel (Thermal treatment) Support tube: Steel (Thermal treatment) Support frames: Coated wire cloth Series Inorganic microfibre External support media External wire mesh Microfibre filtration media Internal wire mesh Internal support media Inner support tube MP Filter elements - Conform to the following ISO standards ISO Verification of collapse/burst resistance. ISO Verification of fabrication integrity and determination of the first bubble point. ISO Verification of material compatibility with fluids. ISO 72 - Method for end load test. ISO Verification of flow fatigue characteristics. ISO Evaluation of pressure drop versus flow characteristics. ISO Multi-pass method for evaluating filtration performance. Element material bsolute filtration New material: New improved ß 200 filter elements with greater efficiency and increased dirt holding capacity Filtering area Filter elements N - P 20 bar Filtering area Filter elements H - P 210 bar Series Inorganic microfibre with acrilic support Filter elements ß 2 (50%) _ 2 _ 1 Dimensions for ß(µm) values ß 20 (95%) 6 19 ß 75 (98,7%) 2,4 4,6 7,8 22 ß 200 (99,5%) Contamination retention as per ISO 4572: Multi-pass test. Filtration ratios ß2 ß10 ß20 P (bar) 20 > > > > ,5 200 > _ > 1,5 > 5 7 N.B. Other materials giving different degrees of filtration are available on request. Type HP / / Type HP / / Values in cm Values in cm Element material Nominal filtration M Series T Series Filtering area Filter elements N - P 20 bar Filtering area Filter elements Square wire mesh (filtration degree is defined in microns by the maximum diameter of a sphere corresponding to the mesh size) Triangular stainless steel wire mesh Type HP M M M Values in cm 2 Type HP /T T - P 80 bar Values in cm 2
4 MP Filtri - Specification Filter body: Materials Working temperature Pressure filter body Collapse pressure filter elements Bypass valve Calibration pressure Compatibility with fluids Head Cast iron (Thermal treatment) Bowl Steel (Thermal treatment) Seals Series: Nitrile (Buna-N) V Series: Viton Maximum working pressure up to 420 bar Test pressure: 60 bar Minimum burst pressure: 1 bar Bypass valve, differential opening pressure: Filter head and bowls compatible for use with: mineral oils (types HH-HL-HM-HR-HV-HG as per ISO 674/4) water-based emulsions (types HFE-HFS as per ISO 674/4) synthetic fluids (types HS-HFDR-HFDS-HFDU as per ISO 674/4) water-glycol (types HFC as per ISO 674/4) Seals Series Nitrile (Buna-N) compatible with mineral oils (types HH-HL-HM-HR-HV-HG as per ISO 674/4) water-based emulsions (types HFE-HFS as per ISO 674/a) Bypass valve Brass Reverse flow (Only for 15/ series) Steel Indicator Brass (with vitou seal) From -25 to +110 C For temperatures outside this range, please consult our Sales Network Organization Fatigue test: a filter body subjected to pressure impulses from 0 to 420 bar will withstand cycles N Series: T Series: H Series: B: 6 bar ± 10% 20 bar 80 bar 210 bar Filter elements s per ISO 294; suitable for mineral oils (types HH-HL-HM-HR-HV-HG as per ISO 674/4) and synthetic fluids ( and M series only) (types HS-HFDR-HFDS-HFDU as per ISO 674/4) For water-based emulsions (types HFE-HFS as per ISO 674/4) and fluids other than those mentioned, please consult our Sales Network Organization. water - glycol (types HFC as per ISO 674/4) V Series Viton compatible with synthetic fluids (types HS-HFDR-HFDS-HFDU as per ISO 674/4) Types of indicators Visual indicator Electrical indicator Visual-electrical indicator (Complete with Viton seals) Description: FHP series filters are fitted with indicators switching at a pressure of 5 bar ± 10% (for N elements series) 7 bar ± 10% (for H and T elements series) 10 bar ± 10% (for H and T elements series) With bypass 5 bar setting: V7 Series With bypass 5 bar setting: N7 Series With bypass 5 bar setting: E7-K7 Series Without bypass 7 bar setting: V8 Series Without bypass 7 bar setting: N8 Series Without bypass 7 bar setting: E8-K8 Series For K visual-electrical indicator, specify the voltage (f.i. K71 = LED 24 volt) J series - Thermal lockout Electrical Indicators available - contact MP Filtri Without bypass 10 bar setting: V9 Series Without bypass 10 bar setting: N9 Series Without bypass 10 bar setting: E9-K9 Series { 1-24 Volt Volt - 20 Volt 4
5 MP Filtri - Specification K - E - N Series Supply voltage (50/60 Hz) (V) Vca 125 Vca Vcc 0 Vcc 125 Vcc Resistive load () ,5 0,25 Inductive load () 2 2 0,0 0,0 CONNECTOR DIN 40 ELECTRICL CONNECTION E - N SERIES N.C. N.O. ELECTRICL CONNECTION K SERIES N.C. N.O. Visual V series Electrical N series Visual - Electrical K series Visual - Electrical K series 8 8 8,5 Led /F /F 2 Ø16 G1/2 Ø16 G1/2 Ø16 G1/2 Ø16 G1/2 5
6 Selection & installation information Filter elements types Series bsolute inorganic microfibre filtration media, available in, 6, 10 and 25 micron Example -,, or M Series Metal mesh media, available in 10, 25 and 60 micron Example - M10, M25 or M60 T Series Triangular stainless steel mesh media, available in 10, 25 micron Example -, T25 Please refer to individual pressure drop curves to obtain filter assembly pressure drop information The following filter sizing recommendations are based using a mineral oil fluid at 0 mm 2 /s (cst), with a maximum filter assembly (housing and filter element) pressure drop of 25% of the filter condition indicator (1.25 bar) FHP 0 SERIES /F 2 FHP 0 V Filter ssembly Flow rate l/min N series Flow rate l/min H-T series Bowl Length Port Size BSP/NPT/SE Weight kg /2, /F0 N /2 4, H Ø 68 Led 8 K Flow rates with 0 mm 2 /s fluid viscosity Weight including filter element and diffuser /4 /4 5,7 Lengths Type H Ø E /F 24 /F ,5 E 12 Housing pressure drop curve FHP 0 0,75 Thread connections Type E (15 mm) G1 1/2 BSP M8 G2 G G4 G5 G6 /4 BSP 1/2 NPT /4 NPT SE 8 - /4-16 UNF SE /16-12 UN M8 5/16 UNC 5/16 UNC 5/16 UNC 5/16 UNC 0,
7 Selection & installation information Please refer to individual pressure drop curves to obtain filter assembly pressure drop information The following filter sizing recommendations are based using a mineral oil fluid at 0 mm 2 /s (cst), with a maximum filter assembly (housing and filter element) pressure drop of 25% of the filter condition indicator (1.25 bar) FHP 15 SERIES /F 2 FHP 15 Filter assembly Flow rate l/min N series Flow rate l/min H-T series Bowl length Port size BSP/NPT/SE Weight kg V /4 7, H Ø 80 /F 2 8 Led 8 N K Lengths Type H Flow rates with 0 mm 2 /s fluid viscosity Weight including filter element and diffuser 2 1 9,4 E 57 8,5 E 76 Thread connections Type E (15 mm) 57.2 Ø 9 C G1 /4 BSP M D B G2 G 1 BSP /4 NPT M10 /8 UNC Housing pressure drop curve FHP 15 G4 G5 G6 1 NPT SE /16-12 UN SE /16-12 UN /8 UNC /8 UNC /8 UNC 0,75 Flange connections Type Port B C D E (15 mm) F1 F2 /4 SE PSI/M 1 SE PSI/M 47,6 52,7 22,2 26,19 M10 M10 M10 M10 0, F F4 F5 F6 /4 SE PSI/UNC 1 SE PSI/UNC /4 SE PSI/M /4 SE PSI/UNC 47,6 52,7 50,80 50,80 22,2 26,19 2,80 2,80 /8 UNC /8 UNC /8 UNC /8 UNC M10 M10 /8 UNC /8 UNC 7
8 Selection & installation information Please refer to individual pressure drop curves to obtain filter assembly pressure drop information The following filter sizing recommendations are based using a mineral oil fluid at 0 mm 2 /s (cst), with a maximum filter assembly (housing and filter element) pressure drop of 25% of the filter condition indicator (1.25 bar) H ,75 0, Ø 105 Ch 0 Ø 120 FHP 20 FHP 21 TOP OUTLET PORT /F 46 E 94 Ø Only for FHP E /F 46 Housing pressure drop curve FHP 20/ Ø 126 FHP 20/21 42 /F 2 /F 2 76 D B /F0 8 Led 8 8,5 C Thread connections Flange connections V N K E Type Lengths Type H E (15 mm) G1 1 1/4 BSP M12 G2 G G4 G5 G6 1 1/2 BSP 1 1/4 NPT 1 1/2 NPT SE /8-12 UN SE /8-12 UN M12 1/2 UNC 1/2 UNC 1/2 UNC 1/2 UNC Type F1 F2 F F4 F5 F6 FHP 20/21 SERIES Filter assembly Flow rate l/min N series Flow rates with 0 mm 2 /s fluid viscosity Weight including filter element Port Flow rate l/min H-T series /4 SE PSI/M 1 1/2 SE PSI/M 1 1/4 SE PSI/UNC 1 1/2 SE PSI/UNC 1 1/4 SE PSI/M 1 1/4 SE PSI/UNC B 58,72 69,85 58,72 69,85 66,68 66,68 Bowl length C 0,18 5,71 0,18 5,71 1,75 1,75 Port size BSP/NPT/SE D Weight kg 1 1 1/4 14, /4 1 1/2 1 1/2 16,5 22,5 25,5 E (15 mm) M10 M12 M12 M12 7/16 UNC 1/2 UNC 1/2 UNC 1/2 UNC M14 M12 1/2 UNC 1/2 UNC 8
9 Selection & installation information Please refer to individual pressure drop curves to obtain filter assembly pressure drop information The following filter sizing recommendations are based using a mineral oil fluid at 0 mm 2 /s (cst), with a maximum filter assembly (housing and filter element) pressure drop of 25% of the filter condition indicator (1.25 bar) FHP 25 V N K E /F H ,5 Led 140 Only for FHP 25-4 Ø 120 Ø /F 2 76 FHP 25 SERIES Filter assembly Flow rates with 0 mm 2 /s fluid viscosity Weight including filter element Lengths Type Flow rate l/min N series H Flow rate l/min H-T series Bowl length Port size BSP/NPT/SE Weight kg , ,5 28,5 1,5 19 E B D C Housing pressure drop curve FHP 25 0,75 Flange connections Type Port B C D E (15 mm) 0,25 F1 F2 2 SE PSI/M 2 SE PSI/UNC 77,77 77,77 42,88 42,88 M12 M12 1/2 UNC 1/2 UNC F5 F6 2 SE PSI/M 2 SE PSI/UNC 96,82 96,82 44,45 44,45 M20 M12 /4 UNC /4 UNC 9
10 Pressure drop information General Pressure drop versus flow rate curve information for both housing and filter elements is in accordance with ISO 968 Filter assembly pressure drop - p Total = p Housing + p Filter element Housing pressure drop - The housing pressure drop is proportional to the fluid density Filter element pressure drop - Filter element pressure drop is proportional to kinematic viscosity therefore always check the fluid operating temperature and fluid type to obtain the working viscosity according to the following formula: p 1 Filter element = (working viscosity/brochure viscosity) x p filter element Brochure viscosity 0 mm 2 /s (cst) Selection : Customer requires a 70 l/min filter assembly Mineral oil fluid: ISO VG 46 (46 mm 2 /s (cst) at 40 C) - 10 micron absolute filtration Housing pressure drop - FHP 15-2 with 70 l/min p = 0.12 bar (see curve on page 7) Filter assembly sizing example Filter element pressure drop (brochure viscosity) - HP 15-2H with 70 l/min p = 0.64 bar (see curve on page 12) Filter element pressure drop (working viscosity) - With 46 mm 2 /s (cst) p 1 = 0.64 x ( 46/0 ) = 0.98 bar Filter assembly pressure drop p Total = p Housing + p 1 Filter element = = 1.10 bar { cceptable pressure drop value as per our recommendations The curves were obtained using a mineral oil with a density of 0,86 kg/dm. The p varies proportionally to the density. Bypass valves pressure drop 12 FHP 0 16 FHP FHP Reverse flow valves pressure drop The curves were obtained using a mineral oil with a density of 0,86 kg/dm. The p varies proportionally to the density. 0,75 FHP 15 0,75 FHP 20 0,25 0,
11 Filter elements - N - P 20bar The curves were obtained using a mineral oil with a kinematic viscosity of 0 mm 2 /s (cst). The p varies proportionally to the fluid kinematic viscosity. For the metal mesh filter elements curves (M series), please consult our Sales and Network Organization HP N HP N HP 0-...N HP N HP N HP N HP N HP N HP N
12 Filter elements - H - P 210bar The curves were obtained using a mineral oil with a kinematic viscosity of 0 mm 2 /s (cst). The p varies proportionally to the fluid kinematic viscosity. For the stainless steel mesh filter elements curves (T series), please consult our Sales and Network Organization HP H HP H HP 0-...H HP H HP H HP H HP H HP H Portata l/min HP H
13 Ordering information FHP Top Outlet Port 25 S B W R V Nominal sizes Bowl lengths FHP 0 = 1, 2, FHP 15 = 1, 2 FHP 20 = 1, 2,, 4 FHP 21 = 1, 2,, 4 Filter elements HP 20 series FHP 25 = 1, 2,, 4 Filter elements HP 20 series Integral bypass valve Without bypass With bypass With reverse flow With reverse flow + bypass Nitrile (Buna-N) Viton Seals ( Not available ) for FHP 0 Filter condition indicator M10 M25 M60 T25 Filter elements Inorganic microfibre Bx 200 Square wire mesh Stainless steel wire mesh Ports option Type G1 1/2 BSP /4 BSP 1 1/4 BSP 1 1/4 BSP G2 /4 BSP 1 BSP 1 1/2 BSP 1 1/2 BSP G 1/2 NPT /4 NPT 1 1/4 NPT 1 1/4 NPT G4 /4 NPT 1 NPT 1 1/2 NPT 1 1/2 NPT G5 SE 8 SE 12 SE 20 SE 20 G6 SE 12 SE 16 SE 24 SE 24 F1 F2 F F4 F5 F6 S With threaded hole only T2 With plug V7 Visual 5 bar V8 Visual 7 bar V9 Visual 10 bar N7 Electrical 5 bar N8 Electrical 7 bar N9 Electrical 10 bar E7 Visual - electrical 5 bar E8 Visual - electrical 7 bar E9 Visual - electrical 10 bar K7 Visual - electrical 5 bar 1-24 Volt K8 Visual - electrical 7 bar Volt { K9 Visual - electrical 10 bar - 20 Volt For K visual-electrical indicator, specify the voltage (f.i. K71 = LED 24 volt) Collapse pressure series N T H 20 bar 80 bar 210 bar /4 SE 1 1/4 SE 2 SE 000 PSI/M 000 PSI/M 000 PSI/M _ 1 SE 1 1/2 SE _ 2 SE 000 PSI/M 000 PSI/M 000 PSI/UNC _ /4 SE 1 1/4 SE 000 PSI/UNC 000 PSI/UNC _ 1 SE 1 1/2 SE 000 PSI/UNC 000 PSI/UNC _ /4 SE 1 1/4 SE _ 2 SE 6000 PSI/M 6000 PSI/M 6000 PSI/M _ /4 SE 1 1/4 SE _ 2 SE 6000 PSI/UNC 6000 PSI/UNC 6000 PSI/UNC HP Replacement element MP Filtri - Filtration products will only be guaranteed if original MP Filtri replacement elements and spares are used Data hold in this pubblication are given only for indicative purposes. MP Filtri reserves to introduce modifications to described items in every moment either for technical or commercial reasons. Copyright reserved. 15
14 International standards for contamination fluid control CONTMINTION CODES ISO 4406 CORRESPONDENT CODES NS 168 RECOMMENDED FILTRTION DEGREE TYPICL PPLICTIONS 5 µm 15 µm ßx High precision and laboratory servo-systems Robotic and servo-systems Very sensitive systems where a high degree of reliability is required General equipment of limited reliability Low - pressure equipment not in continuos service Reverse flow valve - Drawing FHP 15 - FHP SERIES IN OUT 1) 2) ) 4) ZERO FLOW FLOW BYPSS REVERSE FLOW 1
15 Notes 14
16 Head Quarter : MP FILTRI S.p.. Italy Via Matteotti, Pessano con Bornago (Milano) Italy Tel / Fax / sales@mpfiltri.com GRET BRITIN MP FILTRI U.K. Ltd. Bourton Industrial Park Bourton on the Water Gloucestershire GL54 2HQ UK Phone: Fax: sales@mpfiltri.co.uk GERMNY MP FILTRI D GmbH m Wasserturm 5 D-662 Heusweiler/Holz Phone: 06806/ Fax: 06806/ mpfiltrink@aol.com FRNCE MP FILTRI FRNCE B.P Trevoux Cedex Tel: Telefax: mpfiltrifrance@wanadoo.fr US MP FILTRI US Inc Quaker Pointe Drive Quakertown, P Phone: Fax: mpusasales@aol.com CND MP FILTRI CND Inc. 210 Jacob Keffer Parkway Concord, Ontario Canada L4K 4W Phone: Fax: mail@mpfiltricanada.com
A complete line of pressure differential visual and electrical indicators are available with this series of filters.
D e s c r i p t i o n FHB series filters are designed for pressure line applications where manifold mounting is a specific requirement. The manifold type filters are designed to integrate onto manifold
More informationMPF filters within this range are suitable for flow rates up to 750 l/min.
D e s c r i p t i o n MPF series filters are designed for return lines, and are installed semi-immersed in a reservoir. Continued Research & Development on both the filter bodies and the filter elements
More informationFMP IN-LINE FILTER SERIES. Maximum working pressure 250 bar. Flow rate to 500 l/min
INLIN FILTR Maximum working pressure 0 bar Flow rate to 00 l/min R.F. Filter Symbol without bypass Filter Symbol with Reverse Flow R.F. Filter Symbol with bypass Filter Symbol with bypass & Reverse Flow
More informationSERIES SF2-250 SUCTION FILTER. Flow rate to 45 gpm
SERIES SF2-250 SUCTION FILTER Flow rate to 45 gpm D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows
More informationOUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter
D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from
More informationMPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min
MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN Maximum working pressure 12 bar Flow rates to 3 l/min D e s c r i p t i o n MPS/MST The spin-on filter series is a complete product range suitable, for
More informationSPIN-ON FILTER - LOW PRESSURE LINE
SERIES MSH SPIN-ON FILTER - LOW PRESSURE LINE Maximum working pressure 5 psi Flow rate to 8 GPM D e s c r i p t i o n MSH working pressure of 5 psi, with a peak pressure This filter MSH series utilises
More informationSERIES SF2-500 SUCTION FILTER. Flow rates to 225 gpm
SERIES SF2-5 SUTION FILTER Flow rates to 225 gpm D e s c r i p t i o n 5 The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 225 gpm and filtration from
More informationD e s c r i p t i o n
e s c r i p t i o n MPH and MPI series filters are designed for returnline applications and provide various installation applications. The filters are installed semiimmersed (MPH) or totally immersed into
More informationSERIES FRI. Maximum working pressure 20 bar Flow rate to 1200 l/min. s.p.a
New Headquarters : MP FILTRI S.p.. Italy Via 1 Maggio, n. 3 Pessano con Bornago (Milano) Italy Tel. +39./973.1 Fax +39./9741497-974188 email: sales@mpfiltri.com http://www.mpfiltri.com GRT BRITIN MP FILTRI
More informationD e s c r i p t i o n
D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from
More informationSERIES. Maximum pressure 110 bar
SERIES Maximum pressure 0 bar F l o w r a t e s t o 9 5 l / m i n Technical data FMP 09 Compatibility Filter housing (Materials) Head: nodized aluminium Housing: nodized aluminium Bypass valve: Steel Pressure
More informationRF2 Maximum pressure 20 bar F l o w r a t e s t o l / m i n
RF2 96 Maximum pressure 20 bar F l o w r a t e s t o 4 5 5 l / m i n Filter housing (Materials) Filter body: luminium over: Nylon Valve: Nylon - Steel nti-emptying valve: Steel Pressure Working pressure:
More informationMPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n
MPH Maximum pressure bar F l o w r a t e s t o l / m i n 6 echnical data housing (Materials) Head: luminium: MPH ---- nodised luminium: MPH 6-8 Painted luminium: MPH 66 Cover: Nylon: MPH --- luminium:
More informationMPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n
MPH Maximum pressure bar F l o w r a t e s t o l / m i n 6 echnical data Filter housing (Materials) Head: luminium: MPH ---- nodised luminium: MPH 6-8 Painted luminium: MPH 66 Cover: Nylon: MPH --- luminium:
More informationFlow rates to 500 l/min
FF 5 Filter housing in according to SE J066 for F filter elements Maximum pressure 50 bar Flow rates to 500 l/min Technical data Filter housing (Materials) ead: Cast iron (chemical heat treatment) ousing:
More informationTHE IMPORTANCE OF AN EFFICIENT FILTRATION
In line high pressure filters HF 745 / HF 748 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the
More informationIn line high pressure filters. HF 735 series
In line high pressure filters HF 735 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the fluid.
More informationFMM bar. Working pressure. Style T. Style D. Style S. Style B D.I. D.I. D.I. D.I.
30 FMM 050 SRIS FMM 050 Working pressure 0 bar Style S Style Style T Style D 3 3 Technical data Filter body (Materials) Head: Cast iron (chemical heat treatment) Housing: Steel (chemical heat treatment)
More informationIn line high pressure filters. HF 725 series
In line high pressure filters HF 725 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the fluid.
More informationNEW. High Pressure filters. FMM 150 series. Maximum pressure up to 420 bar - Flow rate up to 250 l/min
NEW High Pressure filters FMM 50 series Maximum pressure up to 0 bar - Flow rate up to 50 l/min PASSION TO PERFORM FILTER SIZING THE CORRECT FILTER SIZING HAVE TO BE BASED ON THE TOTAL PRESSURE DROP DEPENDING
More informationPressure: Max working 420 bar (6000 psi) (acc. to NFPA T ) Burst 1260 bar (18300 psi) (acc. to NFPA T )
HYDRULIC FILTRTION In line high pressure filters Technical Information Pressure: Max working 420 bar (6000 psi) (acc. to NFP T 3.10.5.1) Burst 1260 bar (18300 psi) (acc. to NFP T 3.10.5.1) Housing Connection
More informationIn line high pressure filters. HF HF 761 series
In line high pressure filters HF 76 - HF 761 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the
More informationWorking pressure. 350 bar. Style B Series FHD 051. Series FHD 325/332 D.I. D.I. D.I. A A
98 FD SRIS FD Working pressure 350 bar Style S Style Series FD 05 Style Series FD 35/33 D.I. D.I. D.I. 99 Technical data body (Materials) ead: Cast iron (chemical heat treatment) ousing: Steel (chemical
More informationFHA 051 Working pressure 6000 psi
6 SRIS Working pressure 6000 psi Style S Style Style T Style D Style V Style Z D.I. 7 8 Technical data Filter body (Materials) Head: Steel (chemical heat treatment) Housing: Steel (chemical heat treatment)
More informationFlow rates to 3000 l/min
MPH Maximum pressure bar Flow rates to l/min echnical data housing (Materials) Head: luminium: MPH nodised luminium: MPH 68 Painted luminium: MPH 66 Cover: Nylon: MPH luminium: MPH nodised luminium: MPH
More informationFHF325 series. Filter housing according to SAE J2066 for HF4 filter elements. High Pressure fi lters
High Pressure fi lters FHF5 series Maximum pressure up to 50 bar Flow rate up to 500 l/min housing according to SAE J066 for HF filter s 95 High Pressure fi lters FILTER SIZING The correct filter sizing
More informationInline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04
Inline Filter MFM Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS 400-15 / steel 1. TECHNICAL SPECIFICATIONS 1.1. FILTER HOUSING Construction The inline filter consists of a filter
More informationPressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )
HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T 3.10.5.1) Burst 840 bar (12200 psi) (acc. to NFPA T 3.10.5.1) Housing
More informationReturn fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters
Return fi lters series Maximum pressure up to bar - Flow rate up to 15 l/min 193 Return fi lters GENERAL INFORMATION Technical data Return filter Maximum pressure up to bar - Flow rate up to 15 l/min Filter
More informationTHE IMPORTANCE OF AN EFFICIENT FILTRATION
Tank mounted return line filters HF 554 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the fluid.
More informationFiltrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181
Common HYDRAULIC FILTRATION Side wall mounting suction filters Technical Information Connection Ports: 1-1 1/4-1 1/2 BSP (other thread options on request) 1 1/2 SAE J518-3000/M12 Housing Materials: Cover:
More informationDIN Filter element according to DIN Low & Medium Pressure filters. Maximum pressure up to 60 bar - Flow rate up to 330 l/min
Low & Medium Pressure filters & series Maximum pressure up to 60 bar Flow rate up to 0 l/min DIN 550 09 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable
More informationHigh Pressure fi lters. FHP series. Maximum pressure up to 420 bar - Flow rate up to 750 l/min. High Pressure fi lters
igh Pressure fi lters FP series Maximum pressure up to bar Flow rate up to 7 l/min igh Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending
More informationPressure: Max working 160 bar (2300 psi) (acc. to NFPA T ) Burst 480 bar (6900 psi) (acc. to NFPA T )
HYDRULIC FILTRTION F16-XD series In line medium pressure filters Technical Information Pressure: Max working 16 bar (3 psi) (acc. to NFP T 3.1..1) Burst 48 bar (69 psi) (acc. to NFP T 3.1..1) Housing Connection
More informationBy-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane
HYDRAULIC FILTRATION Spin-on, tank top return filters Technical Information Pressure: Max working 12 bar (175 psi) (acc. to NFPA T 3.10.17) Burst 20 bar (290 psi) (acc. to NFPA T 3.10.17) Connection Ports:
More informationPressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)
HYDRAULIC FILTRATION Return filters, tank top mounting, inside-to-outside filtration Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.10.5.1) Burst 16 bar (232 psi) (acc. to
More informationLDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min
Low & Medium Pressure filters LDP & series Maximum working pressure up to 6 MPa (60 bar) Flow rate up to 0 l/min 7 Low & Medium Pressure filters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE
More informationConnection Ports: 3/4 1 1/4 BSP (other thread options on request)
HYDRAULIC FILTRATION Medium pressure, in line spin-on filters Technical Information Pressure: Max working (acc. to NFPA T 3.10.17): FA-4-1x: 34,5 bar (500 psi) FA-4-21: 24 bar (348 psi) Burst (acc. to
More informationReturn Line Filter RF
HYDAC return line filters type RF are designed to be mounted directly on tank tops. Inline mounting is also possible. Return Line Filter RF Flow rates up to 5, l/min Pressure range up to 25 bar Material:
More informationPressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)
HYDRULIC FILTRTION In line medium pressure filters Technical Information Housing Pressure: Max working F8 D1x port size 1/ & 3/4 : 4 bar (6 psi) F8 D1x port size 1 : 3 bar (4 psi) F8 D14x: 3 bar (4 psi)
More informationPressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 500 l/min Pressure range up to 315 bar Material: SG Iron/ADI, Steel
Manifold Mounted, Rear Flanged Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 5 l/min Pressure range up to 35 bar Material: SG Iron/ADI, Steel . DESCRIPTION.. FILTER HOUSING
More informationPressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)
HYDRAULIC FILTRATION F8-D1 series In line medium pressure filters Technical Information Housing Pressure: Max working F8 D1x port size 1/ & 3/4 : 4 bar (6 psi) F8 D1x port size 1 : 3 bar (4 psi) F8 D14x:
More informationMATERIALS CARTRIDGES PRESSURES VALUES TESTS CARRIED OUT ON FILTER ELEMENTS
1 OIL FILTER DESCRIPTION Many years of in-field experience have shown the necessity of more and more efficient controls on the contamination level of hydraulic fluids and fuels. With this goal uppermost
More informationPressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )
HYDRAULIC FILTRATION Tank top return filters Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.1..1) Burst 16 bar (232 psi) (acc. to NFPA T 3.1..1) Housing Connection Ports:
More informationRETURN FILTERS. MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass
COMPONENTS RC MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass APPLICATION EXAMPLE PRESSURE (ISO 10771-1:2002) Max working:
More informationFILTERS. PUMP CARE - Suction filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW
FILTERS HYDRAULIC DIVISION - Suction filters SD TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW SPARE PARTS ORDERING INFORMATION DINSIONS OF
More information525 Stainless steel high pressure filters. FZP series. Maximum pressure up to 420 bar. Stainless steel high pressure fi lters
Stainless steel high pressure fi lters FZP series Maximum pressure up to 0 bar 55 Stainless steel high pressure filters FILTER SIZING The correct filter sizing have to be based on the variable pressure
More informationFilter. Rücklauffilter 3-Loch Serie HF 502. Bestellnr. Innengewinde G. Code. Typ. (ohne Filterelement)
Filter Bestellnr. (ohne Filterelement) Typ Innengewinde G Code Rücklauffilter 3-Loch Serie HF 52 3-4- HF52-.6-GD-B-H-Z-XD-DA /2 HHRK62 3-4-5 HF52-2.77-GD-B-H-Z-XD-DA /2 HHRK22 3-4- HF52-2.77-GE-B-H-Z-XD-DA
More informationPressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm
HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T 3.10.5.1) Burst 330 bar (4800 psi) (acc. to NFPA T 3.10.5.1) Housing
More informationFiltering elements differential collapsing pressure tested in compliance with ISO 2941:
DESCRIPTION Many years of in-field experience have shown the necessity of more and more efficient controls on the contamination level of hydraulic fluids and fuels. With this goal uppermost in its mind,
More informationConnection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)
HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1.5.1): F1-XD4/63/1: 1 bar (15 psi) F1-XD16/25/4: 8 bar (12 psi) Housing Burst (acc. to
More informationInline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar
RFL inline filters are designed for inline mounting in hydraulic and lubrication systems. Inline Filter RFL Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar * For larger flow rates,
More informationConnection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)
HYDRAULIC FILTRATION F4-DMD series In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1..1): F4-DMD/8/11: 7 bar (11 psi) F4-DMD1/3/4: 4 bar (8 psi) Housing Burst
More informationRETURN FILTERS. MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass
COMPONENTS RB MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass APPLICATION EXAMPLE PRESSURE (ISO 10771-1:2) Max working: 0 kpa
More informationLMP series. 305 Low & Medium Pressure filters MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min
Low & Medium Pressure fi lters LMP - series Maximum pressure up to 8 bar - Flow rate up to l/min 5 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable
More informationInline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01.
Change-Over Inline Filter RFLD Cast Version Flow Rates up to 3 l/min* Pressure Range 25/4/64 bar With Ball Change-Over Valve * For higher flow rates, please refer to brochure RFLD Welded Version E 7.9.2/.4
More informationFluid Cooling Industrial COLW Series
Fluid Cooling Industrial COLW Series 0916 COPPER & STEEL CONSTRUCTION Performance Notes Ideal for independent cooling and filtering of system oils Utilizes a high efficient EK series shell & tube (finned
More informationPressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF
Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF up to 600 l/min, up to 315 bar 60 110 140 160 240 280 330 500 660 1.X 660 2.X 990 1320 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING
More informationHIGH PRESSURE FILTERS
APPLICATION HIGH PRESSURE FILTERS For Manifold Block Mounting Series DF...P Pressures to 45 psi Flows to 18 gpm HYDAC DF...P High Pressure Filters are designed to be mounted directly onto the manifold
More informationFiltrec elements are tested also according to ISO 2942, ISO and ISO 3968
HYDULIC FILTTION F-1 series Spin-on filters Technical Information Pressure: Max working 12 bar (175 psi) (acc. to NFP T 3.10.17) Burst 20 bar (290 psi) (acc. to NFP T 3.10.17) Connection Ports: 3/4 1 1/2
More informationPressure Filter DF...K P, DF...M P, Flange Mounted
Pressure Filter, DF...M P, Flange Mounted up to 550 l/min, up to 260 bar DF...M P 330...1.X 160 240 280 500...1.X 660...1.X 660...2.X 990...2.X 1320...2.X 660...3.X 990...3.X 1320...3.X 1. TECHNICAL SPECIFICATIONS
More informationNFH Low Pressure Filters
PPLICTIONS NFH Low Pressure Filters Pressures to 360 psi Flows to 450 gpm Water Removal Capability 4 Ports HYDC NFH In-line Return Filters are designed for use on hydraulic power units, machine tools,
More informationHIGH PRESSURE FILTERS
APPLICATION HIGH PRESSURE FILTERS For Manifold Block Mounting Series DF...P Pressures to 4 psi Flows to 18 gpm HYDAC DF...P High Pressure Filters are designed to be mounted directly onto the manifold block
More information10 Hydraulic Filters
1 Hydraulic Filters Introduction................................... 1-3 HF65 Series................................. 1-9 HF66 Series................................ 1-15 HF67 Series................................
More informationDuplex Pressure Filters
Duplex Pressure Filters Series DFDK Ball Valve Selector Pressures to 45 psi Flows to 9 gpm APPLICATIONS HYDAC DFDK Duplex Filters are ideal for use on hydraulic test equipment, robots, or other critical
More informationMPT SERIES RETURN FILTER
MPT SRIS The series of filters MPT has specifically been designed for use on mobile power packs for industrial, mobil and lift truk applications. The MPT filter range is suitable for flow rates up to 50
More informationHIGH PRESSURE FILTERS
HIGH PRESSURE FILTERS Series DF & LF Pressures to 6 PSI Flows to 18 GPM APPLICATION HYDAC DF & LF In-line High Pressure Filters are designed for use on hydraulic power units, machine tools, plastics machinery,
More information10 Hydraulic Filters
1 Hydraulic Filters Introduction.... 1- HF65 Series.... 1-9 HF66 Series.... 1-15 HF67 Series.... 1-21 HF68 Series.... 1-1 Dual Spin-On Assembly.... 1-5 Introduction Hydraulic Filtration Systems Cummins
More informationHIGH PRESSURE FILTERS Series HF2P
HIGH PRESSURE FILTERS Series HF2P Pressures to 3000 psi Flows to 25 GPM Port Size 3/4 APPLICATION HYDAC HF2 Inline High- Pressure Filters are designed for use on hydraulic power units, machine tools, plastics,
More informationTHE IMPORTANCE OF AN EFFICIENT FILTRATION
Tank mounted return line filters HF 57 / HF 575 / HF 578 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants
More informationFilter. Spin-on Filter. Spin-on Filterelement Serie HF 620. Innengewinde. Bestellnr. (ohne Filterelement) Code. Typ
Filter Bestellnr. (ohne Filterelement) Typ Innengewinde G Code Spin-on Filter Serie HF 620-1000 HF620.20-B00-GE-XA-DA-XB-DA HHT03084-1050 HF620.20-B02-GE-XA-DA-XB-DA 3/4 HHT03163-1100 HF620.20-B17-GE-XA-DA-XB-DA
More informationFilter. Spin-on Filter. Spin-on Filterelement Serie HF 620. Innengewinde. Bestellnr. (ohne Filterelement) Code. Typ
Filter Bestellnr. (ohne Filterelement) Typ Innengewinde G Code Spin-on Filter Serie HF 62 3-2-1 HF62.2-B-GE-XA-DA-XB-DA HHT384 3-2-15 HF62.2-B2-GE-XA-DA-XB-DA 3/4 HHT3163 3-2-11 HF62.2-B17-GE-XA-DA-XB-DA
More informationChange-Over Pressure Filter DFDK
Change-Over Pressure Filter up to 2500 l/min, up to 315 bar 30 60 110 140 160 240 280 330 500 660 1.x 660 2.x 990 2.x 1320 2.x 1320 3.x 2640 3.x 3960 3.x 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING
More informationReturn Line Filter HF4R up to 450 l/min, up to 10 bar
Return Line Filter HF4R up to 450 l/min, up to 10 bar 9" 18" 27" 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed in accordance with international regulations.
More informationSeries RFL In-Line Filter
APPLICATION Series RFL In-Line Filter Pressures 2 bar Flows to 400 l/min HYDAC RFL In-Line Filters are designed for in-line mounting. These filters can be used in hydraulic, flushing, and for extraction
More informationFPG-MDS PRESSURE FILTERS MATERIALS PRESSURE BYPASS VALVE WORKING TEMPERATURE COMPATIBILITY (ISO 2943) HYDRAULIC DIAGRAM.
MATERIALS Head: Aluminium alloy Bowl: Steel Bypass valve: Steel Seals: NBR Nitrile (FKM - on request fluoroelastomer) Indicator housing: Brass PRESSURE Max working: 5 MPa ( bar) Collapse, differential
More informationLMP series
Low & Medium Pressure fi lters LMP 95-95-95 series Maximum working pressure up to.5 MPa (5 bar) - Flow rate up to 000 l/min 7 Low & Medium Pressure filters Introduction FILTER SIZG DEX CALCULATION CORRECTIVE
More informationSeries RFLD Duplex In-Line Filter
APPLICATION Series RFLD Duplex In-Line Filter Welded Pressures to 230 psi Flows to 3900 gpm HYDAC RFLD in-line filters are designed for in-line mounting and are mainly used in continuously operating systems.
More informationHydraulic Filtration. Product Range. Low & Medium Pressure Filters. Return Filters MPFX MPTX MFBX. China United Kingdom India Canada
M Y (Not LMP900-901/902-903/950-951/952-953-954) Positioned on the return line to the tank, return filters perform the task of filtering fluid and preventing particles entering the system - externally
More informationHIGH PRESSURE FILTERS
APPLICATION HIGH PRESSURE FILTERS For Manifold Block Side Mounting Series DF...QE Pressures to 4 psi Flows to 18 gpm HYDAC DF...QE High Pressure Filters are designed to be side mounted directly onto the
More informationInline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron
NF filters are designed for inline mounting and as tank-top mounted return line filters. These filters can also be used on filling, flushing and off-line units. Inline Filters NF Flow rates up to 3,500
More informationPRESSURE FILTERS. BYPASS VALVE Setting: 170 kpa (1,7 bar) ± 10% WORKING TEMPERATURE From -25 to +110 C
COMPONENTS MATERIALS Head: Aluminium alloy Spinon cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile (FKM on request fluoroelastomer) Indicator housing: Brass APPLICATION EXAMPLE PRESSURE (ISO
More information22PD/32PD Series High Pressure Duplex Filters Max 260 l/min bar
/ Series Max 26 l/min - 21 bar A duplex design with a wide application capability Designed to offer continuous operation during element change The / Series utilizes a duplex design with integrated balancing
More informationSeries TSW Sheet No J. SUCTION FILTER, horizontal tank mounted. Dimensions: mounting surface
SUCTION FILTER, horizontal tank mounted Sheet No. 1905 J Series TSW 210-310 Dimensions: type TSW 210 TSW 310 connection - 20 SAE -20 SAE A 12.09 15.47 B 11.57 14.96 C 11.42 14.76 D 8.62 12.00 E.26.30 weight
More informationHD 790 HD 990 In-line mounting Operating pressure up to 630 bar Nominal flow rate up to l/min
High Pressure Filters Worldline HD 79 HD 99 In-line mounting Operating pressure up to bar Nominal flow rate up to. l/min Description Application In the high pressure circuits of hydraulic systems. Performance
More informationPressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX
Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX up to 2000 l/min, up to 420 bar DF/DFF...1.X/2.X 30 60 110 140 160 240 280 330 500 660 990 1320 1500 2000 3000 4000 DF...3.X DFFX...1.X/2.X
More informationHD 790 HD 990 In-line mounting Operating pressure up to 630 bar / 9137 psi Nominal flow rate up to l/min / gpm
High Pressure Filters Worldline 4 HD 79 HD 99 In-line mounting Operating pressure up to bar / 97 psi Nominal flow rate up to. l/min / 4. gpm Description Application In the high pressure circuits of hydraulic
More informationHigh Pressure Filters HD 044 HD 064. Flangeable Operating pressure up to 500 bar Nominal flow rate up to 105 l/min e
High Pressure Filters HD HD Flangeable Operating pressure up to bar Nominal flow rate up to l/min.3-e Description Application In the high pressure circuits of hydraulic systems. Performance features Protection
More informationInline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar
Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar 160 240 260 280 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The filter housings are designed in accordance with international
More informationOff-line Oil Filter Module Pi 8400
Off-line Oil Filter Module Pi 8400 Volume flow l/min 1. Features Compact, ready-to connect oil filter module for modern hydraulic and lubrication systems Low noise internal gear pump Minimum loss of performance
More informationLow Pressure Filter Spin-on Cartridges HC/OC
Low Pressure Filter Spinon Cartridges HC/OC Nominal pressure 10/16/25 bar (140/230/360 psi), nominal size up to 160 1. Features High performance filters for modern hydraulic systems Modular design Compact
More informationNFHD Modular Duplex Filter System Pressures to 360 psi Flows to 450 gpm 4 Ports
NFHD Modular Duplex Filter System Pressures to 360 psi Flows to 450 gpm 4 Ports PPLICTIONS HYDC NFHD Return Line Filters are designed for use on hydraulic power units, machine tools, plastics injection
More informationFPK 02 AP280. Pressure Line High Pressure Filters In-Line up to 420 bar. Mix&Match to Get What You Need
FPK 02 AP280 Pressure Line High Pressure Filters In-Line up to 420 bar Mix&Match to Get What You Need Donaldson's Mix&Match system provides the great performance and functional advantages of custom-engineered
More informationReturn Line Filter RFM with 4-Hole Mounting
Return Line Filter with 4-Hole Mounting Tank-top mounted versions: up to 850 l/min, up to 10 bar 75 90 150 165 185 210 270 330 500 600 661 851 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING Construction
More informationOIL FILLER AND AIR BREATHER FILLER CAPS
OIL FILLER ND IR RETHER FILLER CPS The complete series of oil filter and makes it possible to meet all market demands. Metal and plastic styles suitable for use on mobile equipment are available. s perform
More informationHigh Pressure Filters Worldline 400 HD 790 HD 990. In-line mounting Operating pressure up to 9137 psi Nominal flow rate up to gpm. 40.
High Pressure Filters Worldline 4 HD 79 HD 99 In-line mounting Operating pressure up to 97 psi Nominal flow rate up to 64. gpm 4.9-us Description Application In the high pressure circuits of hydraulic
More informationReturn / Suction fi lters In-line. LMP 124 series MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min. Return / Suction fi lters
Return / Suction fi lters Inline LMP series Maximum pressure up to 8 bar Flow rate up to l/min 9 Return / Suction fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure
More informationSuction Filter SF/SFM/SFF and Suction Filter Elements S/S..
Suction Filter /M/F and Suction Filter Elements S/S.. up to 500 l/min Filters: 60 110 160 240 330 M 330 F 400 F 500 Elements: S SH. SU. SG. 1. TECHNICAL SPECIFICATIONS 1.1 FILTER HOUSING Construction The
More informationES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min
Suction Filters ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min Description Application To be installed in the suction line of the pumps of hydraulic systems resp. upstream
More information