EXPLOSION PROOF DIRECTIONAL CONTROL VALVE TYPE ED6 SERIE 5X CENELEC STANDARD & ATEX DIRECTIVE
|
|
- Angela Bryan
- 5 years ago
- Views:
Transcription
1 EXPLOSION PROOF DIRECTIONAL CONTROL VALVE TYPE ED6 SERIE 5X CENELEC STANDARD & ATEX DIRECTIVE NOT/E 10-60/11-0 CARACTERISTICS Hydraulic : Cetop 3. Maximum pressure in service : 315 ar. Nominal flow. : 60 l/mn. 37 hydraulic symbols. Electric : Protection index : IP 66. CENELEC Standard & ATEX Directive Non-Mining : II GD EExd or EExde, IIC. Temperature range : T6,T5, T. Mining : EEx"d" or EEx"de, I M. Connections on terminal box or taped flange ED6 D5X/EX800 -DC-T6 PA H1d DESCRIPTION OF FUNCTION Directional control valves type ED 6 are solenoid operated directional spool valves. They control start, stop and direction of an oil flow. These valves basically consist of the housing (1), one or two solenoids (), the control spool (3), and return springs (). In unoperated condition the control spool (3) is held in the neutral or starting position by the return springs () (except for type O and OF). The operation of the control spool is by means of oil immersed solenoids (). The force of the solenoid () acts via the plunger (5) on the control spool (3) and pushes it from its rest position into the required end position. When the solenoid is de-energised (), the control spool (3) is returned to its original by the return springs (). An hand emergency button, allows movement of the control spool (3) without solenoid energisation. TYPE : ED6 C or D 5X/O these are directional valves with switching positions and solenoids without locking. When the solenoid is energised there is no median position (without return springs). TYPE : ED6 C or D 5X/OF these are directional valves with switching positions and solenoids with locking in position. CARDRIDGE THROTTLE Use of the cardridge throttle is necessary when, because of the given operating conditions, flow larger than that allowed by the valve operating limits arise during spool cross-over. P ED6...5X A T (P) -1-
2 GENERALITY Oil immersed direct curent solenoid (1) impervious to 100 bar maximum pressure, its mechanical impact strength is approved by the CENELEC for explosion proof equipment. Insulation to IP 66, it can work in tropical climates. The plunger operate in oil to reduce friction, dissipate head and cushions and drives control spool. Direct curent solenoid has the advantages of : - slow movement of the control spool. - energized maintenance of the control valve in intermediary position, is not detrimental to the solenoid. The solenoid housing can be oriented in steps of 90 on directional control valve. ELECTRIC CONNECTION JUNCTION IN OX FOR GROUP I AND IIC The terminal box (3) can be oriented in steps of 5 on the solenoid housing (1). The electrical connector on the outlet terminal box (6) can be arranged horizontally (on terminal box 3) or vertically (on cover ) suitable for cable gland. The execution H is recommended for easy access to the terminal strip. JUNCTION ON FEMALE TAPED FLANGE FOR GROUP II ONLY. Connection with threaded rigid conduit approved in group II only. Seal integrated in the housing. Earth connection (5). The lead wire length normally supplied is 1.5 meter. Active lead wires (7). Earth lead wire (8). One earth connection (5) is available inside or outside the terminal box. Model H1, H,... (ox) Horizontal connection. Model 1,... (Flange) DIFFERENT PROTECTION MODES. 1) Protection EEx "d" On terminal strip (A) inside the explosion proof terminal (3A) box suitable for 0.5 to.5 mm² with cable gland EEx "d". ) Protection EEx "e" On terminal strip () inside the increased safety terminal box (3) suitable for 0.5 to.5 mm² with cable gland EEx "e". 5 CALE GLAND RECOGNIZED PE option (see page 5). Cable gland for unarmored cable EEx"d" IIC recognized in 1/" NPT Also available in EEx"d", EEx"e" group I or group IIC for armoured, unamored or mineral cable : Consult us. 5 --
3 CARACTERISTICS HYDRAULIC Maximum operating pressure : Ports A,, P. Fluid cleanliness bar Maximum operating pressure : Port T. bar 100 With spool type A and, port T must be used as a drain port, if the operating pressure lies above 100 ar. Maximum flow Hydraulic fluid Fluid temperature range Viscosity range Weight : Standard symbol : 3 others symbols (see page 6) Mounting position : C mm /s - valve with 1 solenoid (Kg) - valve with solenoids (Kg) - 3 Positions - Positions 315 see operating curves of pressure drop page 8 Mineral oil De -30 à +70 De.8 à 350 Class 9 NAS 1638 issue 7 D E G Optional. Optional - Horizontal prefered. Y J ELECTRICAL Continous voltages available. V/DC Alternatives voltages available.* V/AC Temperature range with ambiente 0 C. Temperature range with ambiente 50 C. Power requirement. VA Protection index. Duty cycle. Maximum coil temperature. Outlet connection on terminal box or taped flange T6 T6 T5 T6 T6 T6 T6 T6 T6 T5 T5 T T5 T5 T5 T5 T5 T IP66 100% 130 C 1/ NPT-PG11-PG13.5-PG16-M16x1.5-M0x1.5-Mx1.5 *The alternatives voltages are available in EEx d version only. CERTIFICATE OF CONFORMITY European classification code Explosion proof Increased safety Approval number INERIS Group IIC EEx"d" IIC EEx"de" IIC 03 ATEX 00 X Group I EEx"d" I. EEx"de" I. 03 ATEX 00 X STANDARD Conformity to European Standards from 9/9/CE. Europe EN JUNE AMENDMENT 1 ET EN NOVEMER 000 EN JULY 000 EN SEPTEMER
4 HYDRAULIC CODE ED6 5X 3 service ports service ports 3 D Y OF O D D Middle position Normal position E J G Hydraulic housing series number 5X The above refer to symbols D, Y only. Without return spring, with locking control spool. Without return spring. With return springs No Code OF O The above refer to E, J, G,... Ect. With one solenoid side A and side.: With one solenoid side A. With one solenoid side. No code A For use when the flow is greater than the valve capacity, fitted in P line. Throttle Ø 0.8 MM : Throttle Ø 1,0 MM : Throttle Ø 1, MM : Without throttle : No code
5 ELECTRICAL CODE EX * PE Other cable gland, consult us. With standard cable gland. No code : Without cable gland. d e With EEx"d" box. With EEx"e" box. No code. : For EEx"d" taped flange : 1/" NPT : PG 11 3 : PG 13.5 : PG 16 5 : M 16 x : M 0 x : M x 1.50 H V Horizontal connection on the box. Vertical connection. On cover of the box. For taped flange, Group II only. P PV Control pushbutton. Side of Valve. Lock control pushbutton (for hydraulic valve. type OF). No code : Whithout control pushbutton. PA PVA Control pushbutton. Side A of Valve. Lock control pushbutton (for hydraulic valve. type OF). No code : Whithout control pushbutton. T... Temperature range see table on page 3 (For group II only). AC DC Solenoid energized in alterntive current. Solenoid energized in continous current Solenoid power supply in Volt. 1, 8, 96, 110, 00, 0... See table on page 3 for correspondance with the temperature range T, T5, T6. EX800 Solénoid in accordance to European standard CENELEC & ATEX Directive SERIES M Solenoid for use in mining ( Group I). No code : Solenoid for use in explosive atmosphere ( Group II). -5-
6 HYDRAULIC VARIATION SYMOL ( For special execution, consult us). positions with one solenoid side A. = A With return spring. = C positions with one solenoid side. =.../O.../OF = A.../... positions with solenoid sideaand side. Without return spring. With locking control spool. = C.../... positions with one solenoid side A. A A a 0 a 0 PT PT =EA =E1A positions with one solenoid side. A 0 PT b A 0 b PT =E =E1 a 3 positions with one solenoid side A &. A 0 PT b A a 0 b PT =E =E1 =FA =F =GA =G =HA =H =F =JA =J =H =LA =L =L =MA =M =M =PA =P =P =QA =Q =Q =RA =R =R =TA =T =T =UA =U =U =VA =V =V =WA =W =W -6-
7 DIMENSION (In MM) WITH EXPLOSION PROOF AND INCREASED SAFETY OX (Group I & II) 1 : ox cover. : ox housing. 3 : Solenoid housing side A. : Solenoid housing side. 5 : Hydraulic housing. 6 : fixing screws M5 x Housing box can be oriented all 5 on ACE Ref ED6 XXXXX EX DC- T Solenoid housing can be oriented all 90 on A P L = X WITH EEx"d" FEMALE TAPED FLANGE (For group II only, execution 1,...) 1 : Solenoid housing side A. : Solenoid housing side. 3 : Hydraulic housing. : fixing screws M5 x : Taped flange 6 : Length of lead wires normally : 1.5 Meter. Solenoid housing can be oriented all 90 on
8 CONTROL DIMENSION WITH CONTROL TYPE PVA/ OR PA/ WITHOUT CONTROL PUSHUTTON X = 180 maxi X = Ø 5 HYDRAULIC VALVE CONNECTION CETOP T M5 xdia 6 31 A OPERATING LIMIT P CURVES OF PRESSURE DROP Mesured at V : 36 mm ² /S, t : 50 C 11 Curve 7 : Symbol "r" In Switching Position : - A Curve 8 : Symbol "g" In Neutal Position : P - T Pressure Drop P( ar) Flow Q( L/mn)
EXPLOSION PROOF DIRECTIONAL CONTROL VALVE TYPE ED6 SERIE 5X USA NEC STANDARD
EXPLOSION PROOF DIRECTIONAL CONTROL VALVE TYPE ED6 SERIE 5X USA NEC STANDARD R NOT/E 10-0/05-08 CARACTERISTICS Hydraulic : Cetop. Maximum pressure in service : 15 Bar. Nominal flow. : 60 l/mn. 7 hydraulic
More informationEXPLOSION PROOF CHECK VALVE TYPE SEW6 SERIE 3X ATEX DIRECTIVE & CENELEC STANDARD
EXLOSION ROOF CHECK VALVE YE SEW SERIE X AEX DIRECIVE & CENELEC SANDARD NO/E 0-0/-0 CARACERISICS Hydraulic : Cetop. Maximum service pressure : 50 Bar. Nominal flow max. : l/mn. hydraulic symbols : / et
More informationQ max (see specifications table)
41 260/103 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVES EXPLOSION-PROOF VERSION EEx-dIIC SERIES 20 MD1K CETOP 03 E4P4K CETOP P05 E07P4K CETOP 07 E5P4K CETOP 08 E10P4K CETOP 10 p max (see specifications
More informationProportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06
www.atos.com Table TF040-2/E Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 A B DHRZO-A-012/25 A B DHRZA-A-010/25 DHRZ* are
More informationGeneral Specifications DRV DRV-Exm DRV-Exd
direct operated, 3-way pressure reducing valve Q max = 8 l/min pressure range = - 5 bar body stainless steel (optional) Description The proportional pressure reducing valve (3-way function) is used to
More informationp max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par
41 510/112 ED EXPLOSION-PROOF VERSION SOLENOID OPERATED DIRECTIONAL CONTROL VALVES in compliance with ATEX 94/9/EC MD1K ISO 4401-03 (CETOP 03) E4P4K CETOP P05 E07P4K ISO 4401-07 (CETOP 07) E5P4K ISO 4401-08
More informationIntrinsically safe solenoid valves on/off controls - ATEX or IECEX certification
Table E3-/E Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-6/WP/6 On/off valves
More information3-Way Solenoid Valve - Direct Acting
3-Way Solenoid Valve - Direct Acting General application valves for dry or lubricated air, neutral gases and liquids Description: Applications: 3-Way Solenoid Valve - Direct Acting - Normally Closed. Coil
More informationFor single and double operated actuators. Exhaust air recirculation (3/2 way function)
For single and double operated actuators /-, 5/- and 5/ Directional Control Valves Actuation: Electromagnetic Indirectly controlled soft seal spool valves Connection G /4 or /4 NPT NAMUR interface Exhaust
More informationFor double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring
For double-acting actuators 5/ Directional Control Valves Actuation: Electromagnetic Indirect solenoid operation soft seal spool valve Connections G 1/, 1/ NPT, G 1/, NAMUR Interface Crossover-free switching
More informationPilot-Operated Directional Control Valves Series D3 - D11
Catalogue HY11-500/UK Characteristics The D31, D41, D81, D91 and D111 are electrical controlled 4/3 or 4/ way directional control valves. The valves are pilot-operated by an NG6 valve. Pressure and flow
More information3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.
AP64E00DX00X Characteristics to VDI 90 Pressures quoted as gauge pressure Characteristics Symbol Unit Description General Features Spool valve Mounting screws M Tube connection Thread Port size ; 7.4 deep
More informationK Series 3 Way Direct Acting Balanced Poppet Solenoid Valve
Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS
More informationHERION SERIES Indirect solenoid actuated soft seal
HERION 9700 SERIES Indirect solenoid actuated soft seal spool valves with NAMUR interface /, 5/ - G/ For single and double acting actuators Crossover-free switching, switchover function guaranteed even
More informationEx-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS
Table FX1-/E Replaces F6-5 /E E125-16 /E Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS Valve main body Cartridge Mechanical pressure limiter
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBG10D-P and BExBG15D-P Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres BExBG10D-P / BExBG15D-P 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE
More information5/2 and 5/3 Way Valves
Caracteristics to VDI 9 Pressures quoted as gauge pressure Characteristics Symbol Unit Description General Features Ceramic Spool Valve Mounting On base plate, Tube connection Base plate Port size G1/
More informationDHAXW4-07*/M DHOXW-06* Input Power. 32 W (only for 12 and 24 DC) 40 W (only for 110 and 220 DC) 8 W 25 W T6 T4 8 W 25 W T4 T3 T6 T4 T4 T3 25 W 8 W
www.atos.com Table TE137obs/E Stainless steel valves for water base fluids standard or ex-proof solenoid valves with Multicertification TEX, IECEx, EC or CULUS certification UL certified valves are obsolete
More informationSPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot
SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter
More information2/2 Solenoid Cartridge Valve, Size 6
/ Solenoid Cartridge Valve, Size 6 Q max = l/min (.3 gpm), p max = 3 bar (4 psi) Bidirectional leak-proof shutoff, direct acting, with EX-safty solenoid coil Description Valve: Bidirectional leak-proof
More informationPilot Operated Directional Control Valves Series D31DW, D41VW - D111VW
Characteristics The D31, D41, D81, D91 and D111 are electrically controlled 4/3 or 4/ way directional control valves. The valves are pilot operated by an NG6 valve. Pressure and flow of the pilot oil have
More information97100 NAMUR. Technical data
9700 NAMUR /2-, /2- and / Directional control valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /4, /4 NPT NAMUR Interface For single and double operated actuators
More information97105 Inline. Ordering information. Technical data. Accessories See page 5
75 Inline /-, 5/- and 5/ directional valves Actuation: electromagnetic Indirectly controlled soft seal spool valves G /, / NPT, G /, / NPT For single and double operated actuators Crossover-free switching,
More informationPilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW
Characteristics The pilot operated valves are available in 4 sizes: D31DW NG10 (standard) D31NW NG10 (high flow) D41VW NG16 D81VW NG5 (for port diameter up to 6 mm) D91VW NG5 (for port diameter up to 3
More informationHigh Flow Valve Actuation Range. NAMUR Valves G1/4" & G1/2" Piped Valves G1/4" & G1/2" Banjo Valves G1/8" & G1/4"
31-37 High flow NAMUR valves G1/ and G1/ aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding High Flow Valve Actuation
More informationOur policy is one of continued research and development. We therefore reserve the right
For single and double operated actuators 3/2-, 5/2- and 5/3 Directional Control Valves Actuation: Electromagnetic Indirectly controlled soft seal spool valves Connection G /4, /4 NPT NAMUR Interface Exhaust
More informationPorts. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:
Solenoid operated EEx d IIC T6 Description of the Valve Directional control valves direct the flow in various directions (P A with 2/2 valves and P A // A T) with 3/2 valves. Available as 2/2 and 3/2 valves,
More informationMD1JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVES
41 230/102 AD MD1JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVES ALTERNATING CURRENT NFPA D03 (CETOP 03) p max 5,000 psi Q max 18 GPM MOUNTING INTERFACE OPERATING PRINCIPLE NFPA D03 CETOP 4.2-4-03-350
More informationDirectional Control Valve Series D3W Soft Shift
Characteristics The D3W is a 3-chamber, electrically controlled 4/3 or 4/ way directional control valve. It is activated directly by solenoids with screwed in wet pin armature. The soft shifting of this
More information3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface
3/ Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface Suitable for instrumental air, neutral gaseous and liquid fluids and
More informationDirect-acting 3/2 way plunger valve
Direct-acting 3/2 way plunger valve Direct-acting, compact valve with diameter of up to DN 2.5 Vibration-proof, bolted coil system Banjo threaded connection for direct mounting on pneumatic valves Type
More informationCCAI, CCAIF, CCAIF..H
CCAI, CCAIF, CCAIF..H - Zone 1, 2, 21, 22 - Group IIC - Stainless steel junction boxes - Choice of 4 sizes - IP66 AISI 316L stainless steel Grub screws for opening lid Lid opening system Detail of inside
More informationEXPLOSION PROOF DIRECTIONAL CONTROL VALVE TYPE ED6 SERIE 6X NEC STANDARD
EXLOSION ROOF DIRECIONL CONROL VLVE YE ED SERIE X NEC SNDRD CRCERISICS Hydrulic : Cetop. Mximum pressure in service : r. Nominl Flow mx. : 0 l/mn.(see tle) Directionl control vlves re solenoid operted
More informationEasy and safe installation
ATX LUMINAIRES 7 Easy and safe installation 1 2 3 Safety Plus : 1- Mounting can be completed with one hand 2- One handed opening using standard tool 3- Reflector swivels easy access 4- Terminal shield
More informationIntrinsically safe pressure relief valves pilot operated, subplate or in line mounting - ATEX or IECEx certification
able C-1/E Replaces E1-2/E Intrinsically safe pressure relief valves pilot operated, subplate or in line mounting - AE or IECEx certification Main poppet Valve main body Mechanical pressure limiter Cover
More informationINSTALLATION MANUAL XMT MAGNETOSTRICTIVE LEVEL PROBE
INSTALLATION MANUAL XMT MAGNETOSTRICTIVE LEVEL PROBE INDEX INDEX... 2 REVISION INDEX... 2 INTRODUCTION... 3 GENERAL WARNINGS... 3 DESCRIPTION... 4 MAIN COMPONENTS... 5 MECHANICAL INSTALLATION... 6 INSTALLATION
More informationFlameproof Level Sensor (Flameproof F/S FP)
The Deeter F/S FP is magnetic float on a reed switch or Hall Effect sensor stem for control and indication of a liquid level while in a potentially explosive atmosphere. II 1/2G 2D Ex d IIC (*) Ga/Gb Ex
More informationD4D SOLENOID OPERATED DIRECTIONAL CONTROL VALVES DIRECT CURRENT - SERIES 50 ALTERNATING CURRENT - SERIES 60
41 300/198 ED D4D SOLENOID OPERATED DIRECTIONAL CONTROL VALVES DIRECT CURRENT - SERIES 0 ALTERNATING CURRENT - SERIES 60 CETOP 0 p max 30 bar Q max 100 l/min MOUNTING INTERFACE DIRECT-ACTING SOLENOID OPERATED
More informationStainless steel valves for water base fluids standard or ex-proof solenoid valves with Multicertification ATEX, IECEx, EAC or CULUS certification
www.atos.com Table TE137-1/E Stainless steel valves for water base fluids standard or ex-proof solenoid valves with Multicertification TEX, IECEx, EC or CULUS certification Ex-proof solenoid Valve body
More informationOur policy is one of continued research and development. We therefore reserve the right
970 Namur /-, /- and /-Directional control valves Electromagnetic indirectly controlled soft seal spool valves G /4, /4 NPT NAMUR-interface For single and double operated actuators Exhaust air recirculation
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL
More informationINLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1
INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn
More informationSymbol RH F... GENERAL DESCRIPTION. 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction
GENERAL DESCRIPTION List: RH06-1F-1-July 016 4/3- and 4/- way directional control valves with solenoid operation, heavy duty construction Removable AC and DC voltage coils-quick replacement and rotation
More informationControl Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België
Control Equipment 01616E00 Position switches are used to monitor the position of moving parts of machines and plant. Can be used in safety circuits, as the device satisfies EN 60 947-5-1/DIN VDE 0660 part
More informationSepehr Hydraulic Asia
Vickers Solenoid Operated Directional Valves Explosion Proof ATEX, UL, CSA Sepehr Hydraulic Asia DG4V-3S, X4 & X5 DG4V4-1, X5 Table of Contents Introduction General Description... 3 Features and Benefits...
More informationType 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions
More informationElectro-pneumatic control valves
Electropneumatic control valves Visit our website for further information www.crouzet.com 9 Electropneumatic miniature solenoid Miniature solenoid valves Terminals Wires Connector LED indicators Valve
More informationProportional pressure reducing valves type DHRZO direct operated, ISO 4401 size 06
www.atos.com Table TF040-4/E Proportional pressure reducing valves type DHRZO direct operated, ISO 440 size 06 A DHRZO are 3 way, proportional pressure reducing valves, direct operated, with standard ISO
More informationp max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min
41 400/117 ED E*P4 PILOT OPERATED DISTRIBUTOR SOLENOID OR HYDRAULIC (C*P4) CONTROLLED E4P4 CETOP P05 E4R4 ISO 4401-05 E5 ISO 4401-08 p max (see table of performances) Q max (see table of performances)
More informationProportional reducing valves
www.atos.com Table FS015-0/E Proportional reducing valves digital, direct operated, open loop Valve body Proportional solenoid Spool Integral electronics Main connector Fieldbus connector US connector
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More informationExplosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo
Explosion-proof Solenoids II 2 G / II 2 D EEx dm IIC T4, T5, T6 Catalogue Maximum photo ATEX Explosionproof solenoids with flameproof enclosure/encapsulation "dm" According to ATEX directive 94/9/EC and
More informationIntroduction. Pressure drops
Directional control valves CETOP 5/NG0 Introduction The ARON directional control valves NG0 designed for subplate mounting with an interface in accordance with UNI ISO 440-05 - 04-0 - 94 standard (ex CETOP
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
/-, 5/- 5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx
More information97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT
97 Inline /, 5/ & 5/ spool valves electromagnetic actuated, indirectly controlled G /, / NPT For single and double operated actuators Crossover-free switching, switch-over function guaranteed even with
More informationExplosion and flame-proof cast iron electric motors
Explosion and flame-proof cast iron electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 160 3 phases Voltage 230/400 V 50Hz Voltage 265/460V 60Hz Types of mounting
More information7/S1 FIRE DAMPER PPZEN. v 2.5 (en)
7/S1 v.5 (en) FIRE DAMPER PPZEN www.klimaoprema.hr 39 TABLE OF CONTENTS Product description... Range... Fire classification according to EN 13501-3... Operating mechanisms and dimensions... Operating manual...
More informationDirectional Control Valve Series D1VW
Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. A wide variety of spool options
More information4/3, 4/2 and 3/2 explosion-proof solenoid directional valve
01/06 4/3, 4/2 and 3/2 explosion-proof solenoid directional valve Type G...WE10...L3X 2.22 Size (NG) 10 Up to 315 bar Up to 120 L/min Contents Function and configuration Specifications 03 Spool symbols
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
/2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx
More informationExplosion and flame-proof single phase electric motors
Explosion and flame-proof single phase electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 112 Single phase Voltage 230 50Hz Voltage 265 60Hz Types of mounting
More informationQ max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25
41 420/103 ED DSP7 PILOT OPERATED DISTRIBUTOR SOLENOID OR HYDRAULIC(DSC7) CONTROLLED SERIES 10 CETOP 07 p max (see performance ratings table) Q max 300 l/min MOUNTING INTERFACE CETOP 4.2-4-07-320 The DSP7
More informationATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017
ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue 2017.1, Released December 13, 2017 Clark Cooper A Division of Magnatrol Valve Corp. 941 Hamilton avenue Roebling,
More informationSentronic PLUS 614 Series
Sentronic PLUS 64 Series Proportional Technology www.asco.com PRESSURE CONTROL: 64 SERIES SENTRONIC PLUS Sentronic PLUS Sentronic PLUS is a digitally operated pressure regulator valve. This valve accurately
More informationN Series Ex d Stainless Steel
MUR Mounted, Pilot Operated Spool Type Solenoid Valve Flame Proof Stainless Steel Enclosure, COMO Interface Series Stainless Steel MUR Mounted, Pilot Operated Spool Type Solenoid Valve IIC T4/T6 Flame
More informationSolenoid valve VDHT standard BSP (British Standard Pipe)
Technical data sheet standard BSP (British Standard Pipe) danfoss.high-pressurepumps.com 521B1166 / DKCFN.PD.043.A1.02 Index 3. Picture Overview 4. Features 5. Technical data 6. Technical data 7. General
More informationThe cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals
E X - J U N C T I O N B O X Plastic version for Zone 1,, 1 and The robust junction boxes made of plastic and light alloy are featured by their simple mounting and installation capability and their design.
More informationYFC. Limit switch. Ex d. 24 operating head types
Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735
More informationBody: Seat disc: Anod. aluminium body NBR. Connection / Orifice Flow factors Temperature values ( C)
Parker Lucifer Data Sheet 22062004 General information Lucifer ref.: 341N31 Global ref.: 7341NAKBJNM0 Housing ref.: 2995 Coil ref.: 481865 Protection class: Assembly wt. (g): 510 Body: Seat disc: Anod.
More informationDirect mounting NAMUR solenoid valves for process valve actuators New Revolutionary Design- Worldwide Patents Pending
Direct mounting NAMUR solenoid valves for process valve actuators New Revolutionary Design- Worldwide Patents Pending The V-Solenoid II Standard Series ATEX EX Series Intrinsically Safe Series ExProof
More informationDirectional valve elements L808103P (ED4-PT1) of Tank unloaded excess flow. RE Edition: Replaces:
Directional valve elements L80810P with proportional (ED4-PT1) control of Tank unloaded excess flow L80810P (ED4-PT1) RE 1801-1 Edition: 09.2016 Replaces: 07.12 01.2016 Size 6 Series 00 Maximum operating
More informationPilot Operated Proportional DC Valve Series D*1FW / D*1FT
Characteristics The D*1FW / D*1FT pilot-operated proportional DC valves are available in NG10 (CETOP5), NG16 (CETOP7) and NG25 (CETOP8). These valves (D*1FW) are controlled electrically with the external
More informationMECAIR PXA/PEX HAZARDOUS PILOTS CLEAN AIR SOLUTIONS PRODUCT LEAFLET
PXA/PEX CLEAN AIR SOLUTIONS GENERAL CHARACTERISTICS PROTECTION COIL INSULATION COIL VOLTAGE POWER CONSUMPTION ENCLOSURE ELECTRICAL CONNECTION APPROVALS INERIS II 2 Ex td A21 IP67 T135 C Class H 24 V AC
More information4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid
01/08 /3, /2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid 2.1 Type WE 10...L5X Size (NG) 10 Up to 350 bar Up to 150 L/min Contents Function and configurations -03 Specifications 0 Symbols 05
More informationChapter 2: Directional Control Valves
Contents Chapter : Directional Control Valves Series Description Direct operated Pilot operated Page DIN / ISO 06 10 16 5 3 10 16 5 3 Seat valves, electrically operated D1SE - Spool valves, electrically
More information110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W
/27 V - 2/2 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE 963 39 Fluo 2 x 8 W 963 37 Fluo W 963 36 Fluo 2 x 8 W 8, 36 and 8 W fluorescent luminaires Ø 26 mm bi-pin tubes, standard G3
More information3/2-way Rocker Solenoid Valve for pneumatic systems
3/-way Rocker Solenoid Valve for pneumatic systems EEx ia versions Direct-acting High cycling rate Reduced power consumption Type 6104 can be combined with... Sub-base connection Approvals: Type 654 Servo-assisted
More informationThe extendable type 5470 EExi can be used for block modules or for entire valve blocks (tag connectors on top, coil spacing 19 mm).
/2- and 4/2-multi-way valves ; servo-assisted; block assembly or NAMUR flange; DN 4; flow rate: 00 l/min Advantages / Benefits II 2G EEx ia IIC T6 PTB0 ATEX 275 approved Available for block assembly and
More informationProportional relief valves
www.atos.com Table FS007-1/E Proportional relief valves digital, direct operated, open loop Valve body Proportional solenoid Spring Poppet Integral electronics US connector Fieldbus connector Main connector
More informationISO cartridge valves type LIM*, LIRA, LIC*
Table H000/E ISO cartridge valves type LIM, LIRA, LIC Pressure controls: relief, reducing, compensator, ISO 7368 size from 6 to 80 Pmax 40 bar Pressure control valves in ISO cartridge design specific for
More informationSolenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
More informationDIRECTIONAL CONTROL VALVES CETOP3
DIRECTIONAL CONTROL VALVES CETOP3 GENERAL DESCRIPTION RH0...1-...F... Document: DCVC3-1-Aug 2013 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction RH0...1-...F...
More informationEx-proof ISO cartridge valves multicertification ATEX, IECEx, EAC or North American certification CULUS directional control, ISO 7368
Table EX5/E Replaces E/E E5/E Exproof ISO cartridge valves multicertification TEX, IECEx, EC or North merican certification CULUS directional control, ISO 7 Functional cover Poppet Sleeve Spring Ex proof
More informationATEX CABLE GLANDS.
www.gruposiccis.com CONTENTS Page BRASS INTRODUCTION... 2 DN SERIES... 3 DNC SERIES... 4 DAS SERIES... 5 DAD SERIES... DALD SERIES... DNR SERIES... DNCR SERIES... 9 DASR SERIES... 10 DADR SERIES... 11
More informationLimit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark
Limit Switch Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark Features positive opening mechanism (NC contacts only) that opens contacts, thus preventing faulty
More informationGTV Series High Pressure Control Valves
For primary and secondary shut off of fuel control lines Keeping the World Flowing Contents Section Page Technical Specification 3 ¾" & " 2-Way Poppet Valve 4 ¾" & " 3-Way Poppet Valve 5 /2", 2" & 3" 2-Way
More informationComplementary safety valves with /FC mechanical microswitches conforming to Machine Directive 2006/42/CE
www.atos.com Table TE-/E Complementary safety valves with /FC mechanical microswitches confming to Machine Directive 6/4/CE -6*/FC -6*/FC DPHI-7*/FC These valves are provided with FC mechanical microswitch
More informationSOLENOID DIRECTIONAL VALVE
SOLENOID DIRECTIONAL VALVE type DHE direct operated, high performances, ISO 4401 dimensione 06 Spool type, two or three position direct operated valves with high performance threaded solenoids certified
More informationMINING ELECTRIC MOTORS 3KTCR AND 4KTCR
MINING ELECTRIC MOTORS 3KTCR AND 4KTCR Explosion protection Certificate of Conformity: Frame size 71 and 160 Frame size 80, 90, 100, 112, 132 Frame size 180, 200, 225 Frame size 250 Frame size 280 Frame
More informationDirectional Control Valve Series 4D01 (DENISON)
Characteristics The Denison series 4D01 is a solenoid operated directional control valve size NG06 in -chamber design. It is direct operated by wet pin solenoids. The 4D01 is available with a Soft Shift
More informationFlameproof Enclosures
Flameproof Enclosures The range comprises many standard sizes of enclosures manufactured in stainless steel 316L and/or in painted carbon steel. The enclosures allow for utilization of standard electrical
More information3/2 and 4/2 directional seat valves with solenoid actuation
1/16 3/2 and 4/2 directional seat valves with solenoid actuation RE 22049-XN-B2/08.12 Replaces: 07.10 Type M-.SED 6...XN... Size 6 Component series 1X Maximum operating pressure 350 bar Maximum flow 25
More informationDIRECTIONAL CONTROL VALVES CETOP 3/NG6
CETOP 3/NG06 STANDARD SPOOLS CH. I PAGE 0 AD.3.E... CH. I PAGE AD.3.E...J* CH. I PAGE 2 AD3.XS... CH. I PAGE 3 AD3.XD... CH. I PAGE 4 AD.3.V... CH. I PAGE 5 AD.3.L... CH. I PAGE 6 OTHER OPERATOR CH. I
More informationDIRECTIONAL CONTROL VALVES CETOP3
DIRECTIONAL CONTROL VALVES CETOP3 CONTENTS: RH06...1 - electrical control... RH06...2 - hydraulic control... Page 1/17...7/17 8/17...9/17 RH06...4 - mechanical control RH06...6 - pneumatic control......
More informationEV FT3 ES-FT5 ES/GB :09 Pagina 4 FT3 ES* 4
EV FT3 ES-FT5 ES/GB 4 15-07-2008 16:09 Pagina 4 5 1 HOW TO READ THE MODEL CODE FOR VALVES FT3 - ES - * FT3 - ES - (1) (C) - * - (024C) / 10 2 FUNCTIONAL SYMBOLS 1C 1N 1 2 3 4 5 6 7 1 FT3 4-way directional
More informationShort form catalogue ATEX certified products
Short form catalogue certified products Products classified for the use in potentially esplosive atmospheres (Directive Atex 94/9/CE) As from the first of July 2003, all products which are commercialised
More informationSolenoid Valves Type 3963
Mounting and Operating Instructions Solenoid Valves Type 3963 Fig. 1 General Assembly, commissioning and operation of these devices may only be performed by experienced personnel. Proper shipping and appropriate
More informationTechnical Data Sheet
Technical Data Sheet Type 52 2/2-way solenoid valve NC - Valve normally closed (as standard) NO - Valve normally open (as option) Direct operated piston design valve. No differential pressure is necessary
More informationDIRECT IMMERSION RESISTANCE THERMOMETER CONFIGURATIONS
DIRECT IMMERSION RESISTANCE THERMOMETER CONFIGURATIONS WELDED THREADED CONNECTION II 1G/D Ex ia Pt100KI D20 D21 D26-1 D26-2 1 FEATURES The industrial thermometer configuration guarantees a short response
More informationT 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators
T 365 EN Type 365 Solenoid Valve Island To control pneumatic actuators Application The Type 365 Solenoid Valve Island is a compact solution for the central control of pneumatic actuators in chemical and
More information