Selection Information 7-2. Motor Circuit Protectors Automatic Switches Vdc Circuit Breakers 7-35

Size: px
Start display at page:

Download "Selection Information 7-2. Motor Circuit Protectors Automatic Switches Vdc Circuit Breakers 7-35"

Transcription

1 Table of Contents Section Miniature and Molded Case Circuit Breakers H-Frame J-Frame Selection Information -2 QO and QOU Miniature Circuit Breakers -10 QO Miniature Circuit Breakers -10 QO Circuit Breaker ccessories -12 QO and Multi 9 Mounting Bases -13 QOU Miniature Circuit Breakers and QYU Supplementary Protectors -14 QOU ccessories -15 Multi 9 Miniature Circuit Breakers -16 PowerPact Molded Case Circuit Breakers -21 L-Frame PowerPact Family -21 H- and J-Frame Circuit Breakers -22 Q-Frame Circuit Breakers -24 L-Frame Circuit Breakers -25 M-Frame Circuit Breakers -26 P-Frame Circuit Breakers -2 R-Frame Circuit Breakers -28 Motor Circuit Protectors -29 M-Frame P-Frame PowerPact H- and J-Frame Electronic Motor Circuit Protectors -29 H-Frame and J-Frame MCP Selector -30 Motor Circuit Protectors and Motor Protector Circuit Breakers -31 H-, J-, and L-Frame MCP Selection -32 Motor Protection Selection Tables -33 utomatic Switches Vdc Circuit Breakers -35 Mission Critical Circuit Breakers -3 PowerPact Circuit Breaker ccessories -39 Micrologic Electronic Trip Units -46 Masterpact Universal Power Circuit Breakers -50 Ground-Fault Protection -51 Dimensions and Shipping Weights -54 Circuit Breaker Enclosures -56 Photovoltaic Circuit Breakers and Switches -59 R-Frame -1

2 Selection Information Miniature Circuit Breakers Class 500, HOM Circuit Breakers QO Circuit Breakers Circuit Breaker Type Plug-on HOM HOM- CFI HOM- DF HOM- GFI Bolt-on QOB HOM- EPD HOMT QO QO-H QO-VH QH QOT QO- CFI QOB- H QOB-VH QHB QOB- CFI QO- VHCFI QO- DF QOB- VHCFI QOB- DF QOVH- DF QO-GFI QO- VHGFI QOB- VHDF QOB-GFI QOB- VHGFI QO-EPD QO-EPE QOB-EPD QOB-EPE Unit Mount Number of Poles 1 2 1, , 3 a 1, , 2 1, Current Range Interrupting s UL/CS (k) (50/60 Hz) DC s IEC (50/60 Hz)g Special s m b m Vac /240 Vac Y/ Vac d e Vac 480Y/2 Vac 48 Vdc 5f 5 f 5 f 60 Vdc 65 Vdc 125 Vdc 250 Vdc IEC (Icu) CCC Fed. Specs W-C-35B/GEN X X X X X X X X X X X X X X X X X X Other Standard HCR h NOM ccessories and Modifications HCR h HCRi NOM HCR i HCR i HCR i HCR i NOM NOM Shunt Trip j X X X X X X X X X k X X X Undervoltage Trip uxiliary Switches j X X X X X X X X X k X X X X X X X X X X X larm Switch j X X X X X X X X X k X X X X X X X X X X X Handle Operators Handle Padlock ttachment X X X X X l X X X X X X X X X X X X X X X X X X X X X X X Trip System Type Thermal-magnetic X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Molded Case Switch X X X Dimensions (1P Unit Mount) Dimensions (1P Unit Mount) in. (mm) Height Width 3.13 (9) 1.00 (25) 3.5 (89) a 4.5 (121) 0.5 (19) a Depth 2.98 (6) 2.92 (4) a Pages Page 1-13 Pages -10, -11 a See page -54 for dimensions for: QOB2150VH, QOB3110VH, QOB3125VH and QOB3150VH. b HOMT tandem is 30 maximum. HOMT quad tandem has 20 maximum on outside poles, and 50 maximum on the inside poles. c FI, EPD and GFI products are rated 60 Hz only. d See the Supplemental Digest Page 3-22 for 3Ø corner grounded systems. e Vac for 3P only. f 1P and 2P, 10 0 and 3P only. g See the Supplemental Digest Section 10 for circuit breakers with IEC ratings. h HCR on HOM 1P and 2P i HCR on QO, QOB 1P 10 0, 2P , 3P ; QOB-VH 1P 15 0, 2P , 3P j Factory-installed option only k Factory-installed accessories are not available on QOB-VH 2P150 and 3P l Handle padlock attachment available for HOMT quad tandem only. m 2P requires 4P width. 4.5 (121) 4.5 (121) 4.12 (103) -2

3 Selection Information Miniature Circuit Breakers Class 500, 600 QOU Circuit Breakers QOM1 and QOM2 Main Circuit Breakers Multi 9 Circuit Breakers and Supplementary Protectors EDB Circuit Breakers Circuit Breaker Type Plug-on Bolt-on QOM1-VH QOM2-VH EDB EGB EJB Unit Mount QOU QYUa UL 489 C60 UL10 C60b C60H-DC Number of Poles , , 3 1 2, 3 1 2, 3 Current Range Interrupting s UL/CS (k RMS) (50/60 Hz) DC s IEC (50/60 Hz) Icu Vac /240 Vac Vacc Vac Y/2 Vac Vdc 5d 5d 5d Vdc 5e 5e 5e Vdc Vdc Vdc Vdc 5k 240 Vac Vac Special s CCC Xl Xl Xl Fed. Specs W-C-35B/GEN X X X X X X X X X X X X X X X Other Standard HCR f g HCR ccessories and Modifications Shunt Trip Xh Xh Xh Xh X h X X X X X X X X X h X h X h X h X h X h Undervoltage Trip X X X X X X X X uxiliary Switches Xh Xh Xh Xh X X X X X X X X Xh Xh Xh Xh Xh Xh larm Switch Xh Xh Xh Xh X X X X X X X X Xh Xh Xh Xh Xh Xh Handle Operators X X X X X X X X Handle Padlock ttachment X X X X X X X X X X X X X X X X X X X X Trip System Type Thermal-magnetic X X X X X X X X X X X X X X X X X X X X Molded Case Switch X X Dimensions (1P Unit Mount) Dimensions (1P Unit Mount) in. (mm) Height 4.05 (103) 5.09 (129)i 5.60 (142)i 4.21 (10)j 3.19 (81) 3.19 (81) 5.66 (144) Width 0.5 (19) 5.00 (12)i 5.0 (129)i 0.1 (18) 0.1 (18) 0.1 (18) 1.42 (36) 0.98 (25) Depth 2.92 (4) 3.4 (88)i 3.60 (91)i 2.6 (0) 2.6 (0) 2.56 (65) 4.05 (103) Pages Pages -14 Pages 1-2 Pages -16 through -19 Page 9-1 Note: ll circuit breakers on this chart are UL Listed and CS Certified unless otherwise noted. a QYU is a UL 10 supplementary protector. b C60 are recognized components per UL 10. c For information regarding 3Ø corner grounded systems see the Supplemental Digest. Page 3-22 d 1P and 2P, 10 0 and 3P only. e QOU is UL Listed for 60 Vdc per pole , 1P; , 2P; and 0 100, 3P. f HCR on QOU 1P and 3P , 2P ; g UL 489 for DC Telecom applications (1-pole only). h Factory-installed option only i QOM1 and QOM2 dimensions are for 2-pole unit. j 480 V C60 height is 5.56 in. (141 mm). k 2 poles must be wired in series for 500 Vdc. l P and 2P, P

4 Selection Information PowerPact 150 H-Frame Molded Case Circuit Breakers Class 500, 600, PowerPact 250 J-Frame Electronic Trip Version Electronic Trip Version Circuit Breaker Type HD HG HJ HL HR JD JG JJ JL JR Number of Poles 2, 3 2, 3 2, 3a 2, 3a 3 2, 3a 2, 3a 2, 3a 2, 3a 3 Current Range b b b b b Interrupting s 240 Vac UL/CS/NOM 480Y/2 Vac (k RMS) 480 Vac (50/60 Hz) 600Y/34 Vac Vac DC s 250 Vdcc Vdcc 20 IEC 240 Vac 25/25 65/65 100/ / /125 25/25 65/65 100/ / /125 (k RMS) Icu/lcsd 415 Vac 18/18 35/35 65/65 100/ /100 18/18 35/35 65/65 100/ /100 IEC 50/60 Hz Special s CCC X X X X X X X X X X Fed. Specs W-C-35B/GEN X X X X X X X X X X HCR (2P, 3P) X X X X X X X X X X Connections/Terminations Unit Mount X X X X X X X X X X I-Line X X X X X X X X X X Rear Connection Xe Xe X X X X X X X X Drawout Xe Xe X X X X X X X X Optional Lugs Xe Xe X X X X X X X X ccessories and Modifications Shunt Trip X X X X X X X X X X Undervoltage Trip X X X X X X X X X X uxiliary Switches X X X X X X X X X X larm Switch X X X X X X X X X X Motor Operator Xe Xe X X X X X X X X Handle Operators Xe Xe X X X X X X X X Mechanical Interlocks (3P) X X X X X X X X X X Handle Padlock ttachment Xe Xe X X X X X X X X Cylinder Lock (3P) Optional GF Protection Trip System Type Thermal-magnetic X X X X X X X X X Instantaneous-only (MCP) Xf Xf Xf Xf Xf X X Molded Case Switch (utomatic) X X X X X X X X X X Electronic Xf Xf Xf Xf Xf Xf Xf Xf Xf Xf Enclosures (Pages ) General Purpose (NEM 1) X X X X X X X Raintight (NEM 3R) X X X X X X X Dust-tight (NEM 12) X X X X X X X Watertight (NEM 4, 4X, 5) X X X X X X X Explosion Proof (NEM, 9) Dimensions Height 6.4 (163).5 (191) (3P Unit Mount) Width 4.1 (104) 4.1 (104) in. (mm) Depth 3.4 (86) 3.4 (86) Pages (Unit Mount)/(I-Line) Pages -22, -23, -29, -34/9-25 Pages -22, -23, -29, -34, -35/9-25 Note: ll circuit breakers on this chart are UL Listed and CS Certified unless otherwise noted. a 2P in a 3P module. b with electronic trip system c Not available with electronic trip units d Dual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see the Supplemental Digest. Section 10 e Not available in HD and HG 2P rating (2P module). f 3P only. -4

5 Selection Information PowerPact 250 Q-Frame PowerPact 600 L-Frame Molded Case Circuit Breakers Class 500, 600, 800 Circuit Breaker Type QB QD QG QJ LD LG LJ LL LR Number of Poles 2, 3 2, 3 2, 3 2, 3 3, 4 3, 4 3, 4 3, 4 3, 4 Current Range 0 250b 0 250b 0 250b 0 250b Interrupting s 240 Vac UL/CS/NOM 480Y/2 Vac (k RMS) 480 Vac (50/60 Hz) 600Y/34 Vac Vac DC s 250 Vdci 500 Vdcci IEC 240 Vac 10/5 10/5 10/5 10/5 25/25 65/65 100/ / /125 (k RMS) Icu/lcsd 415 Vac 10/5 10/5 10/5 10/5 18/18 35/35 65/65 100/ /100 IEC 50/60 Hz Special s CCC X X X X X Fed. Specs W-C-35B/GEN X X X X HCR (2P, 3P) X X X X X X X X Connections/Terminations Unit Mount X X X X X X X X X I-Line X X X X X X X X X Rear Connection X X X X X Drawout X X X X X Optional Lugs X X X X X ccessories and Modifications Shunt Trip X X X X X Undervoltage Trip X X X X X uxiliary Switches X X X X X larm Switch X X X X X Motor Operator X X X X X Handle Operators X X X X X Mechanical Interlocks (3P) X X X X X X X X X Handle Padlock ttachment X X X X X X X X X Cylinder Lock (3Pf) Optional GF Protectione X X X X X Trip System Type Thermal-magnetic X X X X Instantaneous-only (MCP) X X X X X Molded Case Switch (utomatic) X X X X Electronic X X X X X Enclosures (Pages ) General Purpose (NEM 1) X X X X Raintight (NEM 3R) X X X X Dust-tight (NEM 12) Watertight (NEM 4, 4X, 5) Explosion Proof (NEM, 9) Dimensions Height 6.4 (164) (340) (3P Unit Mount) Width 4.5 (114) 5.51 (140) in. (mm) Depth 3.93 (100) 4.33 (110) Pages (Unit Mount)/(I-Line) Pages -24/9-24 Pages -25/-33 Note: ll circuit breakers on this chart are UL Listed and CS Certified unless otherwise noted. a 2P in a 3P module b I-Line Q-frame circuit breakers are available only. 250 Q-frame unit-mount circuit breakers are limited to Cu conductors only. c Ungrounded UPS systems only. See page -35. Special DC J-Frame only. d Dual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see the Supplemental Digest, Section 10. e Requires factory-installed G shunt trip and 3P module. f Factory-installed option only. g 3P only. h with electronic trip system i Not available with electronic trip units -5

6 Selection Information Molded Case Circuit Breakers Class 600, 612, PowerPact 800 M-Frame PowerPact 1200 P-Frame PowerPact 3000 R-Frame Circuit Breaker Type MG MJ PG PJ PK PL RG RJ RK RL Number of Poles 2, 3 2, 3 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 Current Range Interrupting s UL/CS/NOM (k RMS) (50/60 Hz) DC s IEC (k RMS) Icu/lcsb IEC 50/60 Hz Special s 240 Vac Y/2 Vac Vac Y/34 Vac Vac Vdc 500 Vdca 240 Vac 50/25 65/35 50/25 65/35 50/25 125/65 50/25 65/35 85/65 125/ Vac 35/20 50/25 35/20 50/25 50/25 85/45 35/20 50/25 0/55 85/45 CCC X X X X X X X X X X Fed. Specs W-C-35B/GEN X X X X X X X X X X HCR (2P, 3P) X X X X X X X X X X Connections/Terminations Unit Mount X X X X X X X X X X I-Line X X X X X X Xe Xe Xe Xe Rear Connection Drawout Xd Xd Xd Xd Optional Lugs X X X X X X X X X X ccessories and Modifications Shunt Trip X X X X X X X X X X Undervoltage Trip X X X X X X X X X X uxiliary Switches X X X X X X X X X X larm Switch X X X X X X X X X X Motor Operator Xd Xd Xd Xd Handle Operators Xd Xd Xd Xd Mechanical Interlocks (3P) X X X X Handle Padlock ttachment X X X X X X X X X X Cylinder Lock (3P) Optional GF Protection X X X X X X X X Trip System Type Thermal-magnetic Instantaneous-only (MCP) X X Molded Case Switch (utomatic) X X X X X X X X Electronic X X X X X X X X X X Enclosures (Pages ) General Purpose (NEM 1) X X X X X X Raintight (NEM 3R) X X X X X X Dust-tight (NEM 12) X X X X X X Watertight (NEM 4, 4X, 5) X X Explosion Proof (NEM, 9) Dimensions (3P Unit Mount) Note: Height in. (mm) (325) (413) 15 (381) Widthin. (mm) 8.30 (210) 8.30 (210) (420) Depthin. (mm) 8.10 (205) 8.10 (205) (366) Pages (Unit Mount)/(I-Line) Page -26/9-28 Page -2, -31, -34/9-29 Page -28, -34/9-30 ll circuit breakers on this chart are UL Listed and CS Certified unless otherwise noted. a Ungrounded UPS systems only. See page -35. b Dual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see the Supplemental Digest, Section 10. c Requires breaker with WB suffix d 65/50 k Icu/Ics for ratings. e 1000 and 1200 only.. -6

7 Selection Information Insulated Case Circuit Breakers Class 600, 800 Masterpact 1200 Masterpact 6000 Circuit Breaker Type NT-N NT-H NT-L1 NT-L NT-LF a NW-N NW-H NW-L NW-LF a NW-H NW-L NW-H NW-L Number of Poles 3, 4 3, , 4 3, , 4 3 3, 4 3 Current Range Interrupting s 240 Vac UL/CS/NOM 480Y/2 Vac (k RMS) 480 Vac (50/60 Hz) 600Y/34 Vac Vac DC s 250 Vdc 500 Vdc IECb 240 Vac (k RMS) Icu/Ics 415 Vac Special s CCC Fed. Specs W-C-35B/GEN HCR (2P, 3P) Connections/Terminations Unit Mount X X X X X X X X X X X X X I-Line Rear Connection X X X X X X X X X X X X X Drawout X X X X X X X X X X X X X Optional Lugs ccessories and Modifications Shunt Trip X X X X X X X X X X X X X Undervoltage Trip X X X X X X X X X X X X X uxiliary Switches X X X X X X X X X X X X X larm Switch X X X X X X X X X X X X X Motor Operator X X X X X X X X X X X X X Handle Operators Mechanical Interlocks X X X X X X X X X X X X X Padlock ttachment X X X X X X X X X X X X X Cylinder Lock Optional GF Protection X X X X X X X X X X X X X Trip System Type Thermal-magnetic Instantaneous-only (MCP) Molded Case Switch (utomatic) X X X X X X X X X X X X X Electronic X X X X X X X X X X X X X Enclosures General Purpose (NEM 1) Raintight (NEM 3R) Dust-tight (NEM 12) Watertight (NEM 4, 4X, 5) Explosion Proof (NEM, 9) Dimensions Height 12.6 (322) 1.28 (439) 1.28 (439) 1.28 (439) (3P Unit Mount) Width (286) 1.4 (450) 1.4 (450) (86) in. (mm) Depth (331) (46) (46) (46) Pages Page -50 and Catalog 0613CT0001 Page -50 and Catalog 0613CT0001 Note: ll circuit breakers on this chart are UL Listed and CS Certified unless otherwise noted. a Tested to show arc flash hazard risk category as reference by NFP0E. b See Catalog 0613CT0001 for additional ratings and other information. -

8 Selection Information Molded Case Circuit Breakers Class 500, 600, Frame 100 F-Frame Circuit Breaker Type F (240 V) F FH FHb FH FI FY Number of Poles 1, 2, 3 1 2, , 3 2, 3 1 Current Range Interrupting s UL/CS/NOM (k RMS) (50/60 Hz) DC s IEC (k RMS) Icu/lcsd 240 Vac 10k 25k Y/2 Vac Vac Y/34 Vac Vac Vdcl 5c 10c 10 10c 10c Vdcal Vac 18/9 18/9 415 Vac 10/2.5 10/2.5 10/2.5 10/2.5 10/2.5 10/2.5 6/1.5 IEC 50/60 Hz For additional IEC ratings, see the Supplemental Digest, Section 10. For additional IEC ratings, see the Special s CCC Fed. Specs W-C-35B/GEN X X X X X X X HCR (2P, 3P) X X Connections/Terminations Unit Mount X X X X X X X I-Line X X X X X X X X Rear Connection X X X Drawout Optional Lugs X X X X X X X ccessories and Modifications Shunt Trip Xfe Xf Xf Xf Undervoltage Trip Xfe Xf Xf Xf uxiliary Switches Xfe Xf Xf Xf larm Switch Xfe X f Xf Xf Xf Xf Xf Motor Operator X X X Handle Operators X X X X X Mechanical Interlocks (3P) X X Handle Padlock ttachment X X X X X X X X Cylinder Lock (3Pf) X X Optional GF Protectiong X X X Trip System Type Thermal-magnetic X X X X X X X X Instantaneous-only (MCP) X X Molded Case Switch (utomatic) X Electronic Enclosures (Pages ) General Purpose (NEM 1) X X X X X X X Raintight (NEM 3R) X X X X X X X Dust-tight (NEM 12) X X X X X X X Watertight (NEM 4, 4X, 5) X X X X X X X Explosion Proof (NEM, 9) X X X X X X Dimensions (3P Unit Mount) in. (mm) Height 6 (152) 6 (152) 8 (203) Width 4.5 (114) 4.5 (114) 4.5 (114) Depth 4.13 (105) 4.13 (105) 4.5 (121) Pages (Unit Mount)/(I-Line) Supplemental Digest Section 3 / Pages 9-23 Supplemental Digest Section 3/Page 9-24 Supplemental Digest Section 3/Pages 9-24 Note: ll circuit breakers on this chart are UL Listed and CS Certified unless otherwise noted. f Factory-installed option only. a Ungrounded UPS systems only. See page -35. g Requires factory-installed G Shunt trip and 3P module. b 65 Vac h Not available in HD and HG 2P rating (2P module). c 1Ø 125 Vdc rating only. i 2P in a 3P module. d Dual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see j 3P only. the Supplemental Digest. Section 10 k 1P F is 120 Vac. e Not available on 1P F (240 V). l Not available with electronic trip units -8

9 Selection Information Molded Case Circuit Breaker Class 500, 600, K-Frame 400 L-Frame 600 L-Frame Circuit Breaker Type KI Q4 L LH LI LXI Number of Poles 2, 3 2, 3 2, 3 2, 3 2, 3 3 Current Range Interrupting s 240 Vac UL/CS/NOM 480Y/2 Vac (k RMS) 480 Vac (50/60 Hz) 600Y/34 Vac Vac DC s 250 Vdc Vdca 20 IEC Vac (k RMS) Icu/lcsb 415 Vac 130/65 20/5 20/5 IEC 50/60 Hz For additional IEC ratings, see the Supplemental Digest Section 10. Special s CCC Fed. Specs W-C-35B/GEN X X X X X X HCR (2P, 3P) X X Connections/Terminations Unit Mount X X X X X X I-Line X X X X X X Rear Connection X X X Drawout Optional Lugs X X X X X X ccessories and Modifications Shunt Trip Xc X X X X Undervoltage Trip Xc X X X X X uxiliary Switches Xc X X X X X larm Switch Xc X X X X X Motor Operator X X X X Handle Operators X X X Mechanical Interlocks (3P) Xd Xd Handle Padlock ttachment X X X X X X Cylinder Lock (3P) X X X Optional GF Protection Xec Xd Trip System Type Thermal-magnetic X X X X X Instantaneous-only (MCP) X X Molded Case Switch (utomatic) X Electronic X Enclosures (Pages ) General Purpose (NEM 1) X X X Raintight (NEM 3R) X X X X Dust-tight (NEM 12) X X X X X X Watertight (NEM 4, 4X, 5) X X X X Explosion Proof (NEM, 9) Dimensions Height 8 (203) 11 (29) (301) (3P Unit Mount) Width 4.5 (114) 6 (152).5 (190) in. (mm) Depth 4.5 (121) 5.84 (148) 6.4 (11) Pages (Unit Mount)/(I-Line) Supplemental Digest Section 3 / Pages 9-26 Supplemental Digest Section 3 / Pages 9-2 Supplemental Digest Section 3 / Pages 9-2 Note: ll circuit breakers on this chart are UL Listed and CS Certified unless otherwise noted. a Ungrounded UPS systems only. See page -35. b Dual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see the Supplemental Digest, Section 10. c Factory-installed option only. d Requires circuit breaker with WB suffix. e Requires factory-installed G Shunt trip. vailable only for 3P. f 65/50 k Icu/Ics for ratings -9

10 QO and QOU Miniature Circuit Breakers QO Miniature Circuit Breakers Class 30, 31, 33 / Refer to Catalog 030CT QO miniature circuit breakers are plug-on products for use in QO load centers, NQOD panelboards, NQOD OEM interiors or Speed-D switchboard distribution panels. Bolt-on QOB circuit breakers are for use in NQOD panelboards or interiors.a The QO exclusive Qwik-Open mechanism, with a trip reaction within 1/60th of a second, is standard on all 1P 15 and 20 QO circuit breakers. Table.1: Plug-On Circuit Breakers Table.2: QO-QOB Ring Terminal QO 1P 1 Space Required QOT 1P Tandem 1 Space Required QO 2P 2 Spaces Required QO2200 2P Spaces Required QO 3P 3 Spaces Required mperes b 1P120/240 Vac 2P120/240 Vac Common Trip 2P240 Vacc Common Trip 3P240 Vac Common Trip See Digest Section 1 for load centers, and Section 9 for panelboards and interiors circuit breakers are suitable for use with 60 o C or 5 o C conductors circuit breakers are suitable for use with 5 o C conductors. UL Listed 5 k IR on corner grounded Delta systems. UL Listed as HCR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HCR type circuit breakers. UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. Requires four spaces (1 WG 300 kcmil l/cu.) Suitable for switching 120 Vac fluorescent lighting loads. UL Listed for use ahead of QO, QO-GFI, QO-EPD, QO-FI, QOT,QOCFI, and QO-PL 10 k IR circuit breakers to permit their application at 22 k fault level. 100 maximum branch mounted opposite. Order only. Contact your local Field Office. Includes two circuit breakers (one QO2030 and one QO3020) and handle tie QOTHT. Not suitable for use in 3Ø panels. Use only in 1Ø panel rated 150 or greater. Interrupting s Page -2 ccessories Page -12 DimensionsPage -54 (20% dder) Factory Installed Only mpere Poles Suffix 10 k IR , 2, QO QO QO ,2 15 QO115 d e QO215 d 6.00 QO215H QO315 d QO120 d e QO220 d 6.00 QO220H QO320 d QO125 d QO225 d 6.00 QO225H QO325 d QO130 d QO230 d 6.00 QO230H QO330 d QO135 d QO235 d 6.00 QO335 d Table.3: Wire Sizesb 40 QO140 d QO240 d 6.00 QO240H QO340 d Circuit Breaker mpere Wire Size (WG/kcmil) 45 QO145 d QO245 d 6.00 QO345 d Type 50 QO150 d QO250 d 6.00 QO250H QO350 d l/cu 60 QO160 d QO QO260 d 6.00 QO260H QO360 d P (2) Cu 0 QO10 d 6.00 QO20 d QO20H QO30 d l/cu 80 QO280 d QO280H QO380 d l/cu 90 QO290 d QO290H QO390 d (2) Cu QO 100 QO2100 d QO2100H QO3100 d P l/cu 110 QO2110 d /0 l/cu 125 QO2125 d l/cu 150 QO2150 d fk l/cu, (2) Cu 15 QO215 d fk QO 3P l/cu 200 QO2200 d fk /0 l/cu Molded Case Switch 60 max. 240 Vac QO QO QOB-VH l/cu Molded Case Switch 100 max. 240 Vac QO2000 i QO3000 i QOT l 14 8 Cu 22 k IR d QO-FI, QO-GFI l 14 8 Cu 15 QO115VHe QO215VH g QO315VH g & QO-EPD 40, 50, l 14 6 Cu 20 QO120VHe QO220VH g QO320VH g QO-PL l 14 2 Cu 25 QO125VH 3.00 QO225VH g QO325VH g QO130VH 3.00 QO230VH g QO330VH g Table.4: QOT Tandem Circuit 40 QO140VH 3.00 QO240VH g QO340VH g Breakers 50 QO150VH 3.00 QO250VH g QO350VH g mpere b d 60 QO160VH 3.00 QO260VH g QO360VH g P120/240 Vac 0 QO10VH QO20VH g QO30VH g & 15 QOT QO280VH g QO380VH g & 20 QOT QO290VH g QO390VH g & 20 QOT QO2100VH gh QO3100VH g P120/240 Vac 110 QO2110VH gh QO2125VH gh Order two QOT1515 or QOT2020 circuit breakers and handle tie QOTHT for common switching of center two poles. 150 QO2150VHf g k QO215VHf g k QO2200VHf g k Table.5: Replacement Tandem 42 k IR d Circuit Breakers 40 QOH240 i For Use in Old Style Non-Class CTL 45 QOH245 i QO Load Centers10 k IR 50 QOH250 i mpere b d 60 QOH260 i P120/240 Vac1 Space Required 0 QOH & 15 QO QOH & 20 QO QOH & 20 QO QOH & 30 QO QOH2110 i & 20 QO QOH Two 1P Individual Trip120/240 Vac2 Spaces Required 65 k IR d 15 & 15 Order Two QO1515 or QO2020 circuit breakers and handle tie QOTHT for 15 QH115e QH QH315 d & 20 common switching of center two poles. 20 QH120e QH QH & QH125 i QH225 i QH325 i & 30 QO j QH QH QH & 20 a b QOT Tandem Circuit limiting QOT c tandem circuit breakers have a d mounting cam as shown. Installation e into a QO load center f can only be made in those positions g having a mounting Mounting Cam pan rail slot. Meets Rail Bead Paragraph of the NEC. UL Listed Pan Rail Slot as Class CTL h i j k -10 DE2 Discount

11 1P QO-CFI 1P QO-DF 1P QO-GFI Two-wire QO-SWN Three-wire QO-SWN 3P QO-GFI QO 1P With Shunt Trip 1P QO-PCFI 1P QO-PDF 2P QO-GFI QO and QOU Miniature Circuit Breakers QO rc-fault Circuit Breaker (Pigtail and Plug-On Neutral) QO arc-fault circuit breakers provide protection for Series and Parallel Type rcing as required by the NEC and local code adoption, and comply with UL1699. Table.6: QO rc Fault Circuit Breakersa One-Pole Circuit Breaker Type Combination rc-fault Interrupter (Pigtail Neutral) Plug-On Neutral rc-fault Interrupter Circuit Breaker Type 1P 120 Vac 1P 120 Vac mpere 10 k IR 22 k IR 1 Space Required 1 Space Required 15 QO115CFI QO115VHCFI QO120CFI QO120VHCFI QO115PCFI QO115VHPCFI QO120PCFI QO120VHPCFI Two-Pole mpere 2P 120/240 Vac 2P 120/240 Vac 10 k IR 22 k IR 2 Space Required 2 Space Required Combination 15 QO215CFIf QO215VHCFIf rc-fault Interrupter (Pigtail Neutral) 20 QO220CFIf QO220VHCFIf QO Dual Function Circuit Breaker QO Combination rc Fault and Ground Fault Circuit Interrupters (Dual Function) provide overload and short circuit protection, plus arc fault and ground fault protection in a single device in accordance with the NEC, UL1699 and UL943. Table.: QO Dual Function Circuit Breakers 1P 120 Vac 1P 120 Vac Circuit Breaker Type Combination rc-fault and Ground Fault Circuit Interrupter with Pigtail Neutral mpere 10 k IR 22 k IR 1 Space Required 1 Space Required 15 QO115DF QO115VHDF QO120DF QO120VHDF Plug-On Neutral Combination 15 QO115PDF QO115VHPDF rc-fault and Ground Fault Circuit Interrupter 20 QO120PDF QO120VHPDF QO-GFI Qwik-Gard circuit breakers provide overload and short circuit protection, combined with Class ground fault protection. Class denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 m or more, for people protection. Do not connect to more than 250 feet of load conductor for the total one-way run to prevent nuisance tripping. Table.8: QO-GFI Circuit Breakers Qwik-Gard Circuit Breakers With Ground Fault Circuit Interrupter mpere c () 1P 120 Vac 2P Common Trip 120/240 Vac 3P Common Trip 208Y/120 Vac 10 k IR 22 k IR 10 k IR 10 k IR 1 Space Required 1 Space Required 2 Spaces Required 3 Spaces Required $ Price $ Price $ Price $ Price 15 QO115GFI 233. QO115VHGFI 482. QO215GFI 413. QO315GFI QO120GFI 233. QO120VHGFI 482. QO220GFI 413. QO320GFI QO125GFI 233. QO125VHGFI 482. QO225GFI QO130GFI 233. QO130VHGFI 482. QO230GFI 413. QO330GFI QO240GFI 413. QO340GFI QO250GFI 413. QO350GFI QO260GFId 413. QO-EPD/EPE QO-EPD/EPE circuit breakers provide overload and short circuit protection combined with Class B ground fault protection. They are designed to provide ground fault protection of equipment at a 30 milliampere level (EPD) or 100 milliamp level (EPE). They are not designed to protect people from electrical shock. Table.9: QO-EPD Circuit Breakers mpere c () 1P 120 Vac 2P Common Trip 120/240 Vac 3P Common Trip 240 Vac 10 k IR 10 k IR 10 k IR 1 Space Required 2 Spaces Required 3 Spaces Required $ Price 15QO115EPD QO120EPD 410. $ Price $ Price QO Miniature Circuit Breakers Class 685, 690, 30, 912, 950 / Refer to Catalog 030CT9801 $ Price QO215EPD 660. QO315EPDe 10. QO315EPEe10. QO220EPD 660. QO320EPDe 10. QO320EPEe10. 25QO125EPD 410. QO225EPD QO130EPD 410. QO230EPD 660. QO330EPDe 10. QO330EPEe QO240EPD 660. QO340EPDe 10. QO340EPEe QO250EPD 660. QO350EPDe 10. QO350EPEe QO260EPDd 660. DE2 Discount QO-SWN Switch Neutral Common Trip 2008 NEC Table.10: QO-SWN Circuit Breakers 2 Wire 120 Vac 3 Wire 120/240 Vac mpere 10 k IR 10 k IR c 2 Spaces Required 3 Spaces Required 10 QO210SWN QO215SWN QO315SWN QO220SWN QO320SWN QO225SWN QO230SWN QO330SWN QO240SWN QO340SWN QO250SWN QO350SWN QO-HID HID circuit breakers are for use on circuits feeding fluorescent and high intensity discharge (HID) lighting systems such as mercury vapor, metal halide, or high pressure sodium. These circuit breakers are physically interchangeable with QO circuit breakers. Table.11: QO-HID Circuit Breakers 1P 120/240 Vac 2P Common Trip 120/240 Vac 3P Common Trip 240 Vac mpere 10 k IR 10 k IR 10 k IR c 1 Space Required 2 Spaces Required 3 Spaces Required 15 QO115HID b QO215HID 8.00 QO315HID QO120HID b QO220HID 8.00 QO320HID QO125HID QO225HID 8.00 QO325HID QO130HID QO230HID 8.00 QO330HID QO140HID QO240HID QO150HID QO250HID 8.00 NOTE: QO-K Circuit Breakers are on page -63. QO-HM High magnetic trip circuit breakers are recommended for applications where high initial inrush may occur and for individual dimmer applications. Table.12: QO-HM Circuit Breakers 1P mpere c Cat. No 120 Vac10 k IR 15 QO115HMa b QO120HMa b Non-automatic (Standard) Miniature Switches Miniature non-automatic switches have the same physical packaging as miniature circuit breakers, but open only when the handle is switched to the OFF position. Non-automatic switches provide no overcurrent protection or short circuit protection. They must not be used on systems that have an available fault current greater than the values listed in the table. Non-automatic switches are UL Listed per UL 108 and are CS certified. Table.13: QO Non-utomatic Miniature Switches, 240 Vac 10 k mpere 2P 3P 60 QO QO QO QO a UL Listed as HCR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HCR type circuit breakers. b UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. c circuit breakers are suitable for use with 60 C or 5 C conductors circuit breakers are suitable for use with 5 C conductors. d Suitable only for feeding 240 Vac and 208 Vac two-wire loads. Does not contain load neutral connection. e See note in Instruction Bulletin when using in an enclosure with a QO403 or QON prefix. f For 120/240 V only, not for 208Y/120 V. Interrupting s page -2 ccessories page -12 Dimensions Page

12 QO and QOU Miniature Circuit Breakers QO Circuit Breaker ccessories Class 1130 / Refer to Catalog 030CT Table.14: ccessories for Use with QO and QOB Miniature Circuit Breakers Handle ttachments Description Converts any two adjacent 120/240 Vac 1P QO circuit breakers to independent trip 2P QO1HT 3.80 DE2E Handle Tie: Converts any two adjacent 120/240 Vac 1P side-by-side QOT circuit breakers to independent trip 2P QOTHT 3.80 DE2E Handle tie and lock-off for three 1P QO, QOB circuit breakers QO3HT DE2E Handle Clamp: Clamp for holding QO 1P handle in ON or OFF position QO1LO 3.80 DE2E Clamp for holding QO or Q1 1P, 2P or 3P circuit breaker handles in ON or OFF position HLO DE2E For padlocking 1P QO circuit breaker in ON or OFF position Loose attachment QOHPL 9.50 DE2E Fixed attachment QO1P 10.0 DE2E Handle Padlock ttachment: for For padlocking 1P side-by-side QOT circuit breaker in ON or OFF position QOTHP DE2E Padlocking in ON or OFF position For padlocking 2P and 3P QO-GFI, QO-EPD, and QO-EPE in either ON or OFF position, fixed attachment. GFI2P 9.20 DE2 For 2P and 3P QO and Q1 standard circuit breakers which require padlocking in either ON or OFF position. Loose attachment QO1HPL 10.0 DE2E Fixed attachment QO1PL 10.0 DE2E For padlocking 1P QO circuit breaker in OFF position only, fixed attachment. QO1PF DE2E For padlocking 2P and 3P QO circuit breakers in OFF position only, fixed attachment. QO2PF DE2E Handle Padlock ttachment: for For padlocking 1P QO-GFI, QO-FI, QO-CFI, QO-PCFI, and QO-EPD circuit breakers in OFF position Padlocking in OFF position only, fixed attachment. QOGFI1PF DE2E For padlocking 2P and 3P QO-GFI, QO-EPD, and QO-EPE circuit breakers in OFF position only, fixed attachment. QOGFI2PF DE2E Ring Terminal Ring terminals are available as a factory-installed option. See Page % Price dder DE2 Sub-Feed Lugs 60 2P plug-on 2 spaces required (6 2 l/cu) QO60SL 4.10 DE P plug-on 2 spaces required (12 2/0 l/cu) QO2125SL DE P plug-on 4 spaces required (4 300 l/cu) QO2225SLa DE P plug-on 3 spaces required (12 2/0 l/cu) QO3125SL DE3 Mechanical Interlock ttachment For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted side-byside so that only one circuit breaker can be ON at a time (Not QOU) QO2DTI DE2E With Retaining Kit: QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit breakers in dual power supply applications. Can be used with (2) 2Ps or (1) 2P and (1) 1P QO circuit breakers in QO816L100 load centers. QO2DTIM DE2E a Not suitable for use in 3Ø panels. Use only in 1Ø panel rated 150 or greater. QO1P QO1PL QO1HT QO1LO QO1PF HLO1 QO2DTI Table.15: ccessory Shunt Trip QO1HPL QOTHP QOHPL QO2PF QOGFI2PF Factory-Installed ccessories for Use with QO and QOB Miniature Circuit Breakers Factory-installed electrical accessories take up an additional pole space on QO, QO-GFI, QO-EPD, QO-SWN and QOU circuit breakers. ll C electrical accessories shown below are rated for 50/60 Hz. ccessories are not available for QOB-VH (2P 150 and 3P ) circuit breakers or QO, QOU molded case switches. QO circuit breakers will accept only one accessory per circuit breaker. Undervoltage trip is not available on miniature circuit breakers. Factoryinstalled accessories are not available for QO-FI, QO-CFI or OQ-PCFI rc Fault Circuit Breakers or on QO2150, QO215, or QO2200 circuit breakers. Factory-Installed ccessories Description Rated Voltage Coil Burden Suffix dder Trips the circuit breaker from a remote location by means of a trip C/DC V V coil energized from a separate circuit. 120 Vac shunt trip will V operate at 55% or more of rated voltage. ll other shunt trips will operate at 5% or more of rated voltage. pplication For use with momentary or maintained push button. Not available on QO-GFI, QO-EPD, QO-FI, QO-CFI, QO-PCFI. Shunt trip terminals accept (2) WG Cu. C V 288 V ccessory uxiliary Switches larm Switches Description Monitors circuit breaker contact status and provides a remote signal indicating the circuit breaker contacts are OPEN or CLOSED. pplication uxiliary switch terminals accept (2) WG Cu leads. Used with control circuits and is actuated only when the circuit breaker has tripped. Standard construction includes a normallyopen contact. pplication larm switch terminals accept (2) WG Cu leads. Contact Comb. 1 1B Max. Voltage C 120 C 120 Max. Load 5 5 Suffix dder C DE2 DE2E DE3 Discount

13 QO and QOU Miniature Circuit Breakers QO and Multi 9 Mounting Bases Class 652 / Catalog 030CT9801, 0860CT0201 SN12125 QON120L125I US Mounting Base for UL489 C60 (3 conductor shown) QON2L40 Table.1: Main Lug Table.18: Table.16: QO OEM Mounting BasesUL Recognized Components Voltage System Main Lug 1P Max. No. Mounting Bases Spaces 1P QO Plug-On Mounting BasesFor unit mounting QO, QO-GFI, QO-FI and QO-EPD circuit breakers 1Ø2W 240 Vac Max. 10 k IC (Without Neutral ssembly) 1Ø3W 240 Vac Max. 10 k IC 3Ø3W 240 Vac Max. 10 k IC (Without Neutral ssy.) 3Ø4W 240 Vac Max. 10 k IC Main Wire Size WG/kcmil QON2L Cu, 12 3 l SK9948BW /0 Cu/l SK /0 Cu/l SK /0 Cu/l SK /0 Cu/l SK996BW /0 Cu/l SK /0 Cu/l QON2L Cu, 12 6 l QON24L Cu, 12 3 l QON612L /0 Cu/l QON816L /0 Cu/l QON12L /0 Cu/l QON12L100SFb /0 Cu/l QON112L125I /0 Cu/l QON11224L125I /0 Cu/l QON116L125I /0 Cu/l QON11624L125I /0 Cu/l QON120L125I /0 Cu/l QON124L125I /0 Cu/l QON132L125I /0 Cu/l QON12024L125I /0 Cu/l QON124L150I Cu/l QON124L200I Cu/l QON12L200FTLc Cu/l QON124L200I Cu/l QON124L200DLd (2) Cu/l QON130L200I Cu/l QON142L225I Cu/l QON312L /0 Cu/l QON320L /0 Cu/l QON324L /0 Cu/l QON318L Cu/l QON324L Cu/l QON330L Cu/l QON342L Cu/l QON403L60N Cu/l QON312L125I /0 Cu/l QON320L125I a /0 Cu/l QON324L125I /0 Cu/l QON318L200I Cu/l QON324L200I Cu/l QON330L200I a Cu/l QON342L225I Cu/l QO Plug-On Mounting BasesFor unit mounting QO, QO-GFI and QO-EPD circuit breakers 1Ø2W 240 Vac Max. 10 k IC (Without Neutral ssembly) QOMB1 QOMB2 QOMB Cu 12 2 l 14 4 Cu 12 2 l 14 4 Cu 12 2 l QOB Bolt-On Mounting BasesFor unit mounting QOB, QOB-GFI, QOB-EPD circuit breakers 3Ø3W 240 Vac Max.10 k IC (Without Neutral ssembly) QON3B Cu/l a lso IEC rated and CE marked for IEC Use only Square D brand Type QOXC, QOXD, QOHX and QOE circuit breakers for 415Y/240 Vac max. systems. b Device comes with factory-installed sub-feed lugs. c Device comes with factory-installed feed-thru lugs. d Device comes with factory-installed dual-line lugs. Solid Neutral ssemblies Number of Branch Neutral Terminals SN12125 SN20 SN12200 SN30 SN Multi-9 Mounting Bases for UL489 C60, 240 Vac max. Main Neutral Lug Wire Size Branch Neutral Terminal Wire Size Cu/l Cu l 4 2/0 WG 14 4 WG 12 4 WG 4 2/0 WG 14 4 WG 12 4 WG 4 WG 300 kcmil 14 4 WG 12 4 WG 4 WG 300 kcmil 14 4 WG 12 4 WG 4 WG 300 kcmil 14 4 WG 12 4 WG Description Poles mperes Length in. mm e US US One-conductor Mounting Base US US US US US Two-conductor Mounting Base US US US US US Three-conductor Mounting Base US US US Table.19: ccessories for US Mounting Base for UL489 C60 Description e Main lug kit for US mounting bases, 1 lug per kit, for 6 WG to 300 kcmil cable USMBLK Terminal cover for US mounting base; provides IP20 ingress protection per IEC 60529; suitable for jumper bars or cable USMBTC e DE2 Discount DE3 DE2 Discount -13

14 QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers / QYU Supplementary Protectors Class 20 / Refer to Catalog 030CT Low mpere QOU Miniature Circuit Breakers QOU unit mount miniature circuit breakers (cable-in/cable-out) are ideal for OEM applications. They have the Square D circuit breaker s unique Visi-Trip feature and can be DIN rail-mounted or surface- or flush-mounted using mounting feet. Low mpere QOU General Specifications Common to ll Low mpere QOU Circuit Breakers For convenient flush mount, surface mount or DIN mount UL Listed 48 Vdc (5 k IR) (symmetrical rail 35 x.5 DIN/EN ) UL Listed as HCR Type: 10 0 Single handle with internal common trip High magnetic trip circuit breakers (QOU-HM) are recommended Terminal lug wire size (1) 14 2 WG Cu or l for applications where high initial inrush may occur and for Reversible line and load lugs individual dimmer applications. Field-installable quick connectors For DIN mounting rails, see IEC Starters and Relays, Section 18. High mpere QOU Table.20: QOU Low mpere Miniature Circuit Breakers mpere 1P 120/240 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac a 10 k IR 10 QOU110 QOU210 QOU QOU115 QOU215 QOU215H QOU QOU120 QOU220 QOU220H QOU QOU125 QOU225 QOU225H QOU QOU130 QOU230 QOU230H QOU QOU135 QOU235 QOU QOU140 QOU240 QOU QOU145 QOU245 QOU QOU150 QOU250 QOU QOU160 QOU260 QOU360 0 QOU QOU QOU k IR 15 QOU115VH QOU215VH QOU315VH 20 QOU120VH QOU220VH QOU320VH 25 QOU125VH QOU225VH QOU325VH QOU130VH QOU230VH QOU330VH 35 QOU135VH QOU235VH QOU140VH QOU240VH 45 QOU145VH QOU245VH 50 QOU150VH QOU250VH 60 QOU160VH QOU260VH a QOU-H interrupting rating is 10 k at 240 Vac. Table.21: QOU-HM Miniature Circuit Breakers (10 k IR) mpere 1P 120/240 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac 15 QOU115HM QOU120HM Table.22: QYU UL10 Recognized Supplementary Protectors (5 k IR) mpere 1P 2 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac 10 QYU QYU QYU QYU QYU130 High mpere QOU Circuit Breakers General Specifications Common to ll High mpere QOU Circuit Breakers Flush mount, surface mount, and DIN rail mount. UL Listed as HCR type, Internal common trip. Non-automatic switches have the same physical packaging Non-reversible line and load lugs. as miniature circuit breakers, but provide no overcurrent or Terminal lug wire size (1) 12 2/0 WG Cu or l. short circuit protection. They are UL Listed per UL108 and UL Listed 60 Vdc per pole (5 k IR). (Note: except switches) are CS certified. Table.23: QOU High mpere Miniature Circuit Breakers (10 k IR) mpere 1P 120/240 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac 80 QOU180 QOU280 QOU QOU QOU QOU QOU1100 QOU2100 QOU QOU Table.24: QOU Non-utomatic Switches mpere 1P 120 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac 60 QOU QOU QOU QOU QOU QOU Interrupting s Page -3 ccessories Page -12, -15 Dimensions Page DE2 Discount

15 QO and QOU Miniature Circuit Breakers QOU ccessories Class 20 / Refer to Catalog 030CT9801 4P Jumper Bar ssembly Base Cover and Cover Screw QOUEC Fieldinstallable Quick Connector QOU14100JBF QOURT Field-installable Ring Tongue Terminal Connector Crimp connectors are not included with Square D brand connectors 2P DIN Mounted QOU Circuit Breakers Mounting Foot QOUMF1 Tapped Mounting Foot Suffix 3100 Table.25: ccessories for QOU Low mpere Circuit Breakers (Except as Noted) Description Order Qty. Unit Factory-installed ring tongue terminal, screw, for 1P, 2P, 3P QOU, Suffix dd 20% to price Hex drive 5/32 in. wire binding screw for QOU Suffix dd 20% to price For padlocking 1P low ampere QOU circuit breaker in OFF or ON position QOU1P For padlocking 2P and 3P low ampere QOU circuit breaker in OFF or ON position QOU1PL For padlocking 1P low ampere QOU circuit breaker in OFF position only QOU1PFLc For padlocking 2P and 3P low ampere QOU circuit breaker in OFF position only QOU2PFLc For padlocking 2P and 3P high ampere QOU circuit breaker in OFF position only Suffix -100 dd 20% to price Handle lock-out, ON or OFF position HLO1c P 100 Jumper bar assy. w/front wiring with base, cover and screw 1 QOU14100JBF P 100 Jumper bar assy. w/right side wiring with base, cover and screw 1 QOU14100JBR P 100 Jumper bar assy. w/left side wiring with base, cover and screw 1 QOU14100JBL Ø, 4P, 100 Jumper bar base with front wiring 40 QOU14100BFB Ø, 4P, 100 Jumper bar base with left side wiring 40 QOU14100BLB Ø, 4P, 100 Jumper bar base with right side wiring 40 QOU14100BRB P Jumper bar cover 40 QOU14100CB Mounting screw for jumper bar cover 40 QOU1CMSB P 150 Jumper bar assy. w/front wiring with base, cover and screw 1 QOU16150JBF Ø, 6P, 150 Jumper bar base with front wiring 40 QOU16150BFB Ø, 6P, 150 Jumper bar base with left side wiring 40 QOU16150BLB Ø, 6P, 150 Jumper bar base with right side wiring 40 QOU16150BRB P jumper bar cover 40 QOU16150CB 1.10 Vertical rainproof cover 2P and 3P QO, QOU, F and K Horizontal rainproof cover 2P QO, QOU, and 3P Q2, EH 1P Fingersafe cover for high ampere QOU circuit breaker 1P Fingersafe cover for low ampere QOU circuit breaker Cover plate for one 2P QOU circuit breaker Cover plate for one 3P QOU circuit breaker Cover plate for two 2P QOU circuit breakers Cover plate for three 2P QOU circuit breakers Field-installable ring tongue terminal adaptor Quick connector end connection wiring Quick connector forward or reverse wiring 1P QOU mounting foot 2P QOU mounting foot 3P QOU mounting foot Tapped mounting foot for QOU, 1P and 2P 10 0, 3P Packaged with circuit breaker Suffix dd 20% to price Individually packaged 1 QOUMFS Bulk packed 80 QOUMFS1B 2.30 Mechanical interlock attachment: Used to interlock two circuit breakers mounted side-by-side so that only one circuit breaker can be ON at a time. 1P or 2P circuit breaker can be mounted on the left and interlocked with a 2P or 3P circuit 1 QOU2DTILb breaker on the right. a For use on low and high ampere QOU. b P and 2P, P. c DE2E Discount BCVac BCVBac BCHac BCHBac QOUHFSC1 QOUHFSC1B QOULFSC1 QOULFSC1B QOUCP2 QOUCP2B QOUCP3 QOUCP3B QOUCP4 QOUCP4B QOUCP6 QOUCP6B QOURT QOURTB QOUEC QOUECB QOUFR QOUFRB QOUMF1a QOUMF1Ba QOUMF2a QOUMF2Ba QOUMF3a QOUMF3Ba For QOUQ Low mpere Circuit Breakers with Four-Point Quick-Connect Terminals QOUQ low ampere circuit breakers with four-point quick-connect terminals are provided with permanent factory-installed terminals which are affixed to the Load or OFF end of the circuit breaker. This special terminal will accommodate up to four 1/4-inch insulated female quick connect wire terminations. Total ampacity of these connections must not exceed the rating of the circuit breaker. Table.26: Four-Point Quick-Connect Terminals QOUQ Four-Point Quick-Connect Terminals Poles Order Qty. Unit dder Change QOU to QOUQ Electrical ccessories for QOU Page -12 DE2 DE2 DE2E Discount -15

16 Multi 9 Miniature Circuit Breakers 1P C60 Multi 9 C60 UL 489 Listed 240 V Miniature Circuit Breakers UL 489 Listed and CS 22.2 No. 5.1 for branch circuit protection Eliminates concerns and uncertainty of using a UL 10 device where a UL 489 device is required Replaces fuses in low-ampere range; 1 ratings up to 35 Trip Curve Use Magnetic Release C For typical loads 10 x ampere rating ( 14 for DC) D For high inrush x ampere rating UL 489 C60 Miniature Circuit Breakers Class 860 / Refer to Catalog 0860CT k IR 120 Vac; 2P and 240 Vac) 60 Vdc for 1P and 125 Vdc for 2P (on C-curve circuit breakers only, see table below) Increased installation flexibility with standard box lugs or optional ring terminals llows easy front-mounting and rear wiring when using ring terminals wide range of electrical and mechanical accessories Suitable for reverse feeding Trip-free mechanism Positive indication of contact disconnect 3P C60 2P C60 Box Lug C60 Table.2: UL 489 Circuit Breakers (120/240 V) C Curve 10 Times mpere ( 14 DC) D Curve10 14 Times mpere () 1Pa 2Pb 3P 1P 2P 3P Box Lug/Box Lug Ring Tongue/Ring Tongue a 1P dual rated 120 Vac/60 Vdc. b 2P dual rated 240 Vac/125 Vdc. Ring Tongue C60 Interrupting ratings Page -3 ccessories Page -20 Dimensions Page -54 Mounting Bases Page -13 DIN Mounting Rail Section 18 Box/Ring C60-16 DE2 Discount

17 Multi 9 Miniature Circuit Breakers Multi 9 C60 UL 489 Listed 480V Miniature Circuit Breakers UL 489 Listed, CS C22.2 No. 5.1; lso IEC ; CE marked 480Y/2 10 k (2P and 3P), 2 10 k (1P) 0.5 through 20 1P, 2P, 3P, 18 mm wide per pole UL 489 C Vac and UL489 C60 Miniature Circuit Breakers Class 860 / Refer to Catalog 0860CT0201 Trip Curve Use Magnetic Release 1P UL489 C60 C For typical loads 10 x ampere rating ( 14 for DC) D For high inrush x ampere rating UL 486B Listed single-barrel lug: (2) WG (1-25 mm 2 ) cables, Cu only Optional ring tongue terminals wide range of electrical and mechanical accessories Suitable for reverse feeding Trip-free mechanism Positive indication of contact disconnect Table.28: UL 489 Circuit Breakers (480Y/2 Vac) () C Curve 10 Times mpere ( 14 DC) D Curve10 14 Times mpere 1P 2P 3P 1P 2P 3P Single-Barrel Wire Lug 2P UL489 C60 3P UL489 C MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN Ring Tongue Terminal 0.5 MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN Multi 9 C60 UL 489 Listed Miniature Circuit Breakers for DC Telecommunication pplications limited range of C60 products are UL Listed as UL 489 circuit breakers for protection of DC telecommunications circuits. Table.29: UL 489 Circuit Breakers for DC Telecommunications pplications (1P, 2 Modules, C curve) () () Interrupting Page -3 ccessories Page -20 Dimensions Page -54 DE2 Discount -1

18 Multi 9 Miniature Circuit Breakers 1P C60H-DC 2P C60H-DC UL10 C60H Circuit Breakers, UL1053 Ground Fault Protectors Class 860 / Refer to Catalog 0860CT Multi 9 C60H-DC UL 10 Recognized Supplementary Protectors (250 and 500 Vdc) The C60H-DC supplementary protectors are used in direct current circuits (industrial control and automation, transport, renewable energy, etc.). They provide overcurrent protection within appliances or electrical equipment. Range from k IR at 250 Vdc (1-pole) and 5 k IR at 500 Vdc (2-pole, wired in series) Trip-free mechanism Positive indication of contact disconnect C-Curve: to14 times ampere rating UL 10, IEC , EN , GB , CCC and CE mark. Table.30: Multi 9 C60H-DC UL 10 Recognized Supplementary Protectors 1-Pole Vdc 2-Pole Vdc Current ()a 0.5 MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN MGN a t 25 C/ F, for other temperatures see temperature derating table in Multi 9 Catalog 0860CT0201R1/08 Multi 9 UL1053 Listed GFP Ground Fault Protectors Provides ground fault protection for electrical circuits. vailable in 2P (2-wire) and 4P (3- or 4-wire) versions Provides no thermal or magnetic protection. The circuit must be protected by an upstream device. Contains Si Technology to increase immunity to noise and to minimize the potential for nuisance tripping in noisy electrical environments. Tripped condition due to a ground fault is displayed on the front face by a red mechanical indicator. DIN rail mounting for easy installation. 2P GFP 4P GFP (3- or 4-wire). Table.31: Current () Maximum Sensitivity (m) Multi 9 UL 1053 Listed GFP Ground Fault Protectors 2P UL1053 UL /240 Vac, 240 Vac, 60 Hz 2 Vac, 480Y/2 Vac, 60 Hz IEC Vac, 240 Vac, 50 Hz 4P UL Vac, 480Y/2 Vac, 60 Hz IEC IEC /400 Vac, 240/415 Vac, 50 Hz 230/400 Vac, 240/415 Vac, 50 Hz Tripping Range Family to 29.9 m GFP to 98.9 m GFP to 299 m GFP to 29.9 m GFP to 98.9 m GFP to 299 m GFP to 29.9 m GFP to 98.9 m GFP to 299 m GFP to 299 m GFP to 299 m GFP Interrupting s Page -3 ccessories Page -20 Dimensions Page DE2 Discount

19 1P UL 10 C60 2P UL 10 C60 3P UL 10 C60 4P UL 10 C60 Multi 9 Miniature Circuit Breakers Intended for use within equipment where branch circuit protection is already provided or not needed Range from 0.5 to k 120/240 Vac; 5 k IR at 480Y/2; 10 k 60 Vdc (1P) and 125 Vdc (2P) Suitable for reverse feeding DIN mounting for easy installation UL 10 C60 Supplementary Protectors Class 860 / Refer to Catalog 0860CT0201 wide range of electrical and mechanical accessories Trip-free mechanism Positive indication of contact disconnect Trip Curve Use Magnetic Release B For sensitive equipment x ampere rating C For typical loads 10 x ampere rating ( 14 for DC) Suitable for reverse feeding D For high inrush x ampere rating Table.32: UL 10 Supplementary Protectors () 1P 2P 3P 4P B CurveMagnetic Setting Between 3.2 and 4.8 Times mpere 1 MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG C CurveMagnetic Setting Between and 10 Times mpere 0.5 MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG D CurveMagnetic Setting Between 10 and 14 Times mpere 0.5 MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG MG Interrupting s page -3 ccessories page -20 Dimensions Page -54 DE2 Discount -19

20 Multi 9 Miniature Circuit Breakers C60 ccessories Class 860 / Refer to Catalog 0860CT0201 Electrical ccessories for C60 Circuit Breakers and Supplementary Protectors Possible Combinations Mounted to the left of the circuit breaker with a maximum width of 54 mm Ring Tongue Terminal Kit Spacer Terminal Screw Shield SD larm Switch OF uxiliary Switch Max. 54 mm MX Shunt trip + ux Switch MN Undervoltage Release C60 C60 Padlock ttachment Rotary Handle Front Mounting Kit for C60 1P, 2P, 3P, 4P (1 per circuit breaker) MGN26380 Locking Device Left Side Mount Multi-pole Front Mounting Kit Heavy-duty Padlock ttachment Label Holders for 2, 3 or 4P C60 MGN26381 Locking Device Right Side Mount Comb Bus Bar Table.33: Multi 9 C60 Electrical ccessories Descriptions Control Voltage C60 Width in 9 mm UL/IEC modules Vac Vdc OF uxiliary Switch (1a1b) MG SD larm Switch (1a1b) MG MX Shunt Trip + OF uxiliary Switch (1a1b) MN Undervoltage Release Multi-9 GFP UL 1053 Listed 120 to 480Y/2 Vac; 30, 100, and 300 m; 2P and 4Ps. Ground Fault Protectors See page -18 Handout, 0860HO0602 or Catalog 0860CT0201 Table.34: Multi 9 C60 Mechanical ccessories C60 Descriptions Ring tongue terminal kit for UL10 C60 For one pole Spacer for DIN rail, Not UL Recognized 9 mm wide MG Padlock ttachment (1 per for 1P, 2P, 3P or 4P) 2 per pack MG Heavy-duty Padlock ttachment for C60, Locks OFF only 2 per pack M9PF Padlocking Device Left Side Mount, Locks OFF onlya MGN per pack Padlocking Device Right Side Mount, Locks OFF onlyb MGN P MG Front Mounting Kit 2P MG P MG P MG Label holders for 2, 3 or 4P C60 (Not UL Recognized) Bag of 10 MG Terminal Screw Shield (Not UL Recognized) Bag of two 4P shields MG P MG Terminal cover (Not UL Recognized) 2P MG P MG2695+MG2696 4P MG Ø MG Comb Bus Bar Kit for UL10 C60, 12 poles, Fixed Length 2Ø MG Ø MG Tooth Caps for UL Comb Bus Bar, Bag of Rotary Handle for C60 (Non UL Recognized) Operating Subassembly MG Door Interlock Handle 2P/3P/4P MG Fixed Handle (Front or Lateral) MG Multi-pole Front Mounting Kit Rail Support (20 of 9 mm modules) Hinged Transparent Cover a Left-side mounted padlocking device cannot be used in conjunction with accessories SD, OF, MX or MN. Use rightside mounted padlocking device when accessories are required. b Right-side mounted padlocking device cannot be used in conjunction with VIGI module. Use left-side mounted padlocking device when VIGI Module is required DE2 Discount

21 PowerPact Molded Case Circuit Breakers PowerPact Family Class 611 The PowerPact dvantage Proven Performance: Industry-leading circuit breaker innovation and protection for heavy-duty commercial and industrial applications. Smart: Integrated metering options provide a cost-effective solution to reduce energy consumption, optimize energy costs, and improve energy availablility for your facilities. Flexible: Full range of thermal-magnetic and electronic trip molded case circuit breakers from 15 to 3000, delivering the ratings, configurations, and operators for your unique applications. Simple: Common catalog numbers, standardized ratings, and a full range of field-installable accessories make product selection, installation and maintenance easier than ever. Common Design Features: Mounting holes, door trim, and handle accessories H-Frame 150 J-Frame 250 Q-Frame 250 L-Frame 600 M-Frame 800 P-Frame 1200 R-Frame 3000 Electronic Trip Version Electronic Trip Version Table.35: PowerPact Interrupting s a b Interrupting Voltage B D G J K L R 240 Vac 10 k 25 k 65 k 100 k 65 k 125 k 200 k 480 Vac 18 k 35 k 65 k 65 k a 100 k 200 k 600 Vac 14 k 18 k 25 k 65 k a 50 kb 100 k P-frame K interrupting is 50 k at 480 and 600 Vac. P-frame L interrupting is 25 k at 600 Vac. Table.36: Common Catalog Numbering System Frame Termination Poles Frame Designation Interrupting Terminations 240 Vac 480 Vac 600Vac I-Line H 150 Frame B 10 k L Lugs on Both Ends J 250 Frame D 25 k 18 k 14 k F Bus Bar (No Lugs) Q 250 Frame G 65 k 35 k 18 k M Lugs Line Side Only L 600 Frame J 100 k 65 k 25 k P Lugs Load End Only M 800 Frame K 65 k 65 k 65 k N Plug-in P 1200 Frame L 125 k 100 k 50 k D Drawout R 3000 Frame R 200 k 200 k 100 k S Rear Connected Studs c For amperage of M-, P- or R-frame circuit breakers, add a zero to the three amperage digits; for example, 120 = Description Page H- and J-Frame Circuit Breakers H- and J-Frame Circuit Breakers Q-Frame Circuit Breakers L-Frame Circuit Breakers P-Frame Circuit Breakers R-Frame Circuit Breakers PowerPact H- and J-Frame Electronic Motor Circuit Protectors Motor Circuit Protectors and Motor Protector Circuit Breakers utomatic Switches Vdc Circuit Breakers Mission Critical Circuit Breakers PowerPact Circuit Breaker ccessories Motor Operators and Rotary Handles Locks, Installation ccessories, and Rear Connections Mechanical Lugs Compression Lugs and Power Distribution Connectors (PDC) Terminal Nuts, Terminal Pads, Terminal Shields and ccessories Plug-In and Drawout Mountings Micrologic Electronic Trip Units Micrologic Trip Unit ccessories Voltage mperage c H G L B S Suffix Code Suffix Code 110 Vac Shunt Trip 2/2B uxiliary Switch -21

22 PowerPact Circuit Breakers H- and J-Frame Circuit Breakers Class 611 / Refer to Catalog 0611CT HD and HG 2P Thermal-Magnetic Trip Unit (2P HJ, HL in 3P module) H-Frame Thermal-Magnetic Trip Unit Table.3: H-Frame 150 Thermal-Magnetic UL Current-Limitingd Circuit Breakers(600 Vac, 250 Vdc) With Factory Sealed Trip Unit Suitable for Reverse Connectiona Interrupting (2nd Letter of Catalog Number) Fixed C Current Magnetic D G 40 o Trip bc C Ld Hold Trip 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated H-Frame, 150 2P, 600 Vac 50/60 Hz, 250 Vdc H( )L26015(C) H( )L26020(C) H( )L26025(C) H( )L26030(C) H( )L26035(C) H( )L26040(C) H( )L26045(C) H( )L26050(C) H( )L26060(C) H( )L2600(C) H( )L26080(C) H( )L26090(C) H( )L26100(C) H( )L26110(C) H( )L26125(C) H( )L26150(C) H-Frame 150 3P, 600 Vac 50/60 Hz, 250 Vdc H( )L36015(C) H( )L36020(C) H( )L36025(C) H( )L36030(C) H( )L36035(C) H( )L36040(C) H( )L36045(C) H( )L36050(C) H( )L36060(C) H( )L3600(C) H( )L36080(C) H( )L36090(C) H( )L36100(C) H( )L36110(C) H( )L36125(C) H( )L36150(C) Terminal Wire Range L150HD 14 3/0 WG l or Cu L150HD 14 3/0 WG l or Cu Table.38: J-Frame 250 Thermal-Magnetic UL Current-Limitingd Circuit Breakers (600 Vac, 250 Vdc) With Factory Sealed Trip Unit Suitable for Reverse Connectiona Interrupting (2nd Letter of Catalog Number) djustable C Current Magnetic D G Jd Ld 40 o Trip bc Terminal C Wire Range Low High 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated J-Frame 250 2P, 600 Vac 50/60 Hz, 250 Vdc J( )L26150(C) L15JD J( )L2615(C) /0 WG l or Cu J( )L26200(C) L250JD J( )L26225(C) /0 WG 350 kcmil J( )L26250(C) l or Cu J-Frame 250 3P, 600 Vac 50/60 Hz, 250 Vdc J( )L36150(C) L15JD J( )L3615(C) /0 WG l or Cu J( )L36200(C) L250JD J( )L36225(C) /0 WG 350 kcmil J( )L36250(C) l or Cu a See Supplemental Digest pages 3-2 and 3-3 for circuit breakers with field interchangeable trip units. b To complete catalog number, replace the blank with the appropriate rating (D, G, J, L). c For 100% rated circuit breakers add a C in the 9th character place (for example, HDL26015C or JDL26150C). d Circuit breakers with J, L, and R interrupting ratings are UL certified as current limiting.. Table.39: H- and J-Frame Termination Options Termination Letter = I-Line (See Section 9) F = No Lugs (includes terminal nut kit on both ends) For factory-installed L = Lugs both ends termination, place termination M = Lugs ON end Terminal Nut Kit OFF end letter in the third block of the P = Lugs OFF end Terminal Nut Kit ON end N = Plug-in e D = Drawout e S = Rear Connected e circuit breaker catalog number. H G L Termination Letter Plug-in Drawout Rear Connected e For N and D pricing, add termination pricing on page -45 to price. For S pricing, add termination pricing on page -41 to price. Table.40: H- and J-Frame Interrupting s Interrupting ccessories Page -39 Voltage D G J L R Optional Lugs Page -42 Dimensions Page Vac 25 k 65 k 100 k 125 k 200 k Enclosures Page Vac 18 k 35 k 65 k 100 k 200 k 600 Vac 14 k 18 k 25 k 50 k 100 k -22 DE2 Discount

23 > 3 0 > > 3 0 % Ir Ir (x Io ) I s d(x Ir) PowerPact Circuit Breakers Electronic Trip Version Table.41: H-Frame 150 and J-Frame 250 Electronic Trip UL Current-Limitinga Circuit Breakers (600 Vac) With Factory Sealed Trip Unitb Suitable for Reverse Connection g Electronic Trip Unit Type Function Trip Unit 600 Vac, 50/60 Hz, 3P Micrologic Standard Micrologic Standard Micrologic mmeter Micrologic Energy Micrologic mmeter Micrologic Energy LI 3.2f LSI 3.2Sf LSI 5.2 LSI 5.2E LSIG 6.2 LSIG 6.2E Sensor c H( )L36060(C)U31X H( )L36100(C)U31X H( )L36150(C)U31X 80% Rated H- and J-Frame Circuit Breakers Class 611 / Refer to Catalog 0611CT1001 Interrupting (2nd Letter of Catalog Number) D G Ja La Ra 100% Rated % Rated % Rated % Rated % Rated % Rated % Rated % Rated % Rated Terminal L150HDd 250 J( )L36250(C)U31X L250JDe 60 H( )L36060(C)U33X H( )L36100(C)U33X L150HDd 150 H( )L36150(C)U33X J( )L36250(C)U33X L250JDe H( )L36060(C)U43X H( )L36100(C)U43X H( )L36150(C)U43X L150HDd 250 J( )L36250(C)U43X L250JDe 60 H( )L36060(C)U53X H( )L36100(C)U53X L150HDd 150 H( )L36150(C)U53X J( )L36250(C)U53X L250JDe H( )L36060(C)U44X H( )L36100(C)U44X H( )L36150(C)U44X L150HDd 250 J( )L36250(C)U44X L250JDe 60 H( )L36060(C)U54X H( )L36100(C)U54X L150HDd 150 H( )L36150(C)U54X J( )L36250(C)U54X L250JDe a Circuit breakers with J, L, and R interrupting ratings are UL certified as current limiting. b See Supplemental Digest page 3-2 for circuit breakers with field-interchangeable trip units c For 100% rated circuit breakers, add a C in the 9th character place (for example, HGL36150CU31X, JGL36250CU43X) d L150HD wire range is 14 3/0 WG l or Cu. e L250JD wire range is 3/0 WG 350 kcmil l or Cu. For smaller wire range (4 4/0 WG l or Cu), replace the lug s wire binding screws with the larger binding screws provided. f 3P circuit breakers with this trip unit can be used for 2P applications. g For applications requiring communications see page -49. H-Frame Micrologic Trip Unit Table.42: H- and J-Frame Termination Options Termination Letter - I-Line (See Section 9) F = No Lugs (includes terminal nut kit on both ends) L = Lugs both ends M = Lugs ON end Terminal Nut Kit OFF end P = Lugs OFF end Terminal Nut Kit ON end N = Plug-in h D = Drawout h S = Rear Connected h h For N and D pricing, add termination pricing on page -45 to price. For S pricing, add termination pricing on page -41 to price. Table.43: For factory-installed termination, place termination letter in the third block of the circuit breaker catalog number. H D L T Termination Letter H- and J-Frame Interrupting s Interrupting Voltage D G J L R 240 Vac 25 K 65 k 100 k 125 k 200 k 480 Vac 18 k 35 k 65 k 100 k 200 k 600 Vac 14 k 18 k 25 k 50 k 100 k M o c 2 ic r lo g i. 5 J-Frame Micrologic Trip Unit H-Frame Circuit Breaker with Optional FDM and IFM Modules ccessories page -39 Optional Lugs Page -42 Dimensions Page -55 Enclosures Page -56 DE2 Discount -23

24 PowerPact Circuit Breaker QBL 2P QBL 3P Q-Frame Circuit Breakers Class 034 / Refer to Catalogs: 034CT0201 Table.44: PowerPact Q-Framea250 Thermal-Magnetic Circuit Breaker (240 Vac) Fixed C Interrupting mpere Magnetic Trip B D G J Hold Trip 2P, 240 Vac QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL b QBL QDL QGL QJL Terminal Wire Range #4 WG kcmil l/cu 3P, 240 Vac QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL #4 WG kcmil l/cu QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL QBL QDL QGL QJL b QBL QDL QGL QJL a Replacement lugs and electrical accessories are not available for PowerPact Q-frame circuit breakers. b 250 requires the use of copper cables only. 250 lugs are suitable for copper conductors only Table.45: Q-Frame Termination Options Table.46: Q-Frame Interrupting s Termination Letter Interrupting Voltage = I-Line (See Section 9) For factory-installed termination, B D G J E = Bolt-on I-Line (See Section 9) place termination letter in the 240 Vacc 10 k 25 k 65 k 100 kd F = No lugs third block of the circuit breaker c Q-frame circuit breakers are 240 Vac only. L = Lugs both ends catalog number. d 3P QJ circuit breakers are rated at 208Y/120 Vac only. M = Lugs ON end, studs on OFF end Q G L P = Lugs OFF end, studs on ON end Termination Letter e dd TS suffix for studs on both ends without nuts and washers. See Catalog 034CT0201 for additional information. DimensionsPage -55 EnclosuresPage DE2 Discount

25 PowerPact Circuit Breakers L-Frame Circuit Breakers Class 611 / Refer to Catalogs: 0611CT1001 Table.4: L-Frame 600 Circuit Breakers with Lugs and Factory-Sealed Electronic Trip Units Suitable for Reverse Connectionfl Electronic Trip Unit Type Function Trip Unit Sensor g 80% Rated Interrupting (2nd Letter of Catalog Number) D G J h L h R h 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated Terminal 600 Vac, 50/60 Hz, 3P Micrologic Standard Micrologic Standard Micrologic mmeter Micrologic Energy Micrologic mmeter Micrologic Energy LI 3.3i 600 Vac, 50/60 Hz, 4P Micrologic Standard Micrologic Standard Micrologic mmeter Micrologic Energy Micrologic mmeter Micrologic Energy f g h i j k 250 L( )L36250(C)U31X L400L61K3j LSI 3.3Si LSI LSI 5.3E LSIG LSIG 6.3E LI 3.3 L( )L36400(C)U31X L( )L36600U31X m For N and D pricing, add termination pricing on page -45 to price. For S pricing, add termination pricing on page -41 to price L600LS52K3k 250 L( )L36250(C)U33X L400L61K3j L( )L36400(C)U33X L( )L36600U33X L( )L36400(C)U43X L( )L36600U43X L( )L36400(C)U53X L( )L36600U53X L( )L36400(C)U44X L( )L36600U44X L( )L36400(C)U54X L( )L36600U54X L600LS52K3k L600LS52K3k 250 L( )L46250(C)U31X L400L61K4j LSI 3.3S LSI LSI 5.3E LSIG LSIG 6.3E L( )L46400(C)U31X L( )L46600U31X L600LS52K4k 250 L( )L46250(C)U33X L400L61K4j L( )L46400(C)U33X L( )L46600U33X L( )L46400(C)U43X L( )L46600U43X L( )L46400(C)U53X L( )L46600U53X L( )L46400(C)U44X L( )L46600U44X L( )L46400(C)U54X L( )L46600U54X See Supplemental Digest page 3-4 for circuit breakers with field-interchangeable trip units For 100% rated circuit breakers (250 and 400 only), add a C in the 9th character place (for example, LGL36400CU31X) Circuit breakers with J, L, and R interrupting ratings are UL certified as current limiting. 3P circuit breakers with this trip unit can be used for 2P applications. L400L61K3 terminal wire ranges are (1) 2 WG 600 kcmil Cu or 1) 2 WG 500 kcmil l. L600LS52K3 terminal wire range is (2) 2/0 WG 500 kcmil l/cu. l For applications requiring communicatins see page -49. L-Frame Circuit Breaker Table.48: Termination Letter Termination Options Termination Option I-Line (See Section 9) F No lugs L Lugs both ends M Lugs ON end, terminal nut kit OFF end P Lugs OFF end, terminal nut kit ON end Nm Plug In Dm Drawout Sm Rear Connected For factory-installed termination, place termination letter in the third block of the circuit breaker catalog number. L G L U 4 4 X Termination Letter Table.49: Voltage Interrupting s Interrupting L600LS52K4k L600LS52K4k D G J L R 240 Vac 25 k 65 k 100 k 125 k 200 k 480 Vac 18 k 35 k 65 k 100 k 200 k 600 Vac 14 k 18 k 25 k 50 k 100 k ccessories page -39 Optional Lugs page -42 Dimensions page -55 Enclosures page -56 DE2 Discount -25

26 PowerPact Circuit Breakers M-Frame Circuit Breaker Table.50: M-Frame Circuit Breakers Class 612 / Refer to Catalogs: 0612CT0101 M-Frame 800, Basic Electronic Trip System Type ET 1.0n Factory-Sealed Trip Unit Interrupting Electronic Trip Unit Sensor G J Type Function 2P, 600 Vac 50/60 Hz 300 MGL MJL MGL MJL Fixed 400 MGL MJL Basic Long-time, 450 MGL MJL djustable Instantaneous 500 MGL MJL Trip 600 MGL MJL MGL MJL MGL MJL P, 600 Vac 50/60 Hz 300 MGL MJL Basic Fixed Long-time, djustable Instantaneous Trip 350 MGL MJL MGL MJL MGL MJL MGL MJL MGL MJL MGL MJL MGL MJL Terminal Wire Range (WG/kcmil) L800M23K (3) 3/0 500 l/cu L800M23K (3) 3/0 500 l/cu n The ET 1.0 trip unit cannot be field replaced or have the long-time trip point setting adjusted. It is considered an electronic equivalent of a thermalmagnetic circuit breaker. Table.51: Termination Options Table.52: Frame Interrupting s Termination Letter Termination Option I-Line (See Section 9) F No lugs L Lugs both ends M Lugs ON end, terminal nut kit OFF end P Lugs OFF end, terminal nut kit ON end For factory-installed termination, place termination letter in the third block of the circuit breaker catalog number. M G L Termination Letter Interrupting Voltage D G J L 240 Vac 25 k 65 k 100 k 125 k 480 Vac 18 k 35 k 65 k 100 k 600 Vac 14 k 18 k 25 k 50 k ccessories page -39 Optional Lugs page -42 Dimensions page -55 Enclosures page DE2 Discount

27 Table.53: Type Electronic Trip Unit PowerPact Circuit Breakers P-Frame 1200 (600 Vac, 50/60 Hz) 3Pa Circuit Breaker with Electronic Trip Unit Function Basic Electronic Fixed longtime, Trip Unit (Not djustable Interchangeable) Instantaneous Micrologic Interchangeable Standard Trip Unit Micrologic Interchangeable mmeter Trip Unit Micrologic Interchangeable Power Trip Unit Trip Unit Sensor bc 80% Rated Gb Jb Kb Lbd 100% Ratedc 80% Rated 100% Ratedc 80% Rated 100% Rated c P-Frame Circuit Breakers Class 612 / Refer to Catalog 0612CT % Rated 100% Ratedc Terminal Wire Range 600 P( )L L800M23K 800 P( )L36080 (3) 3/0 WG 500 kcmil l or Cu ET1.0I 1000 P( )L L1200P25K 1200 P( )L36120 (4) 3/0 WG 500 kcmil l or Cu 250 P( )L36025(C)U P( )L36040(C)U L800M23K 600 P( )L36060(C)U31 (3) 3/0 WG 500 kcmil l or Cu LI P( )L36080(C)U P( )L36100(C)U L1200P25K 1200 P( )L36120(C)U31 (4) 3/0 WG 500 kcmil l or Cu 250 P( )L36025(C)U P( )L36040(C)U L800M23K 600 P( )L36060(C)U33 (3) 3/0 WG 500 kcmil l or Cu LSI P( )L36080(C)U P( )L36100(C)U L1200P25K 1200 P( )L36120(C)U33 (4) 3/0 WG 500 kcmil l or Cu 250 P( )L36025(C)U P( )L36040(C)U L800M23K 600 P( )L36060(C)U41 (3) 3/0 WG 500 kcmil l or Cu LI P( )L36080(C)U P( )L36100(C)U L1200P25K 1200 P( )L36120(C)U41 (4) 3/0 WG 500 kcmil l or Cu 250 P( )L36025(C)U P( )L36040(C)U L800M23K 600 P( )L36060(C)U43 (3) 3/0 WG 500 kcmil l or Cu LSI P( )L36080(C)U P( )L36100(C)U L1200P25K 1200 P( )L36120(C)U43 (4) 3/0 WG 500 kcmil l or Cu 250 P( )L36025(C)U P( )L36040(C)U L800M23K 600 P( )L36060(C)U44 (3) 3/0 WG 500 kcmil l or Cu LSIG P( )L36080(C)U P( )L36100(C)U L1200P25K 1200 P( )L36120(C)U44 (4) 3/0 WG 500 kcmil l or Cu 250 P( )L36025(C)U63E1 400 P( )L36040(C)U63E L800M23K 600 P( )L36060(C)U63E1 (3) 3/0 WG 500 kcmil l or Cu LSI 5.0P 800 P( )L36080(C)U63E P( )L36100(C)U63E L1200P25K 1200 P( )L36120(C)U63E1 (4) 3/0 WG 500 kcmil l or Cu 250 P( )L36025(C)U64E1 400 P( )L36040(C)U64E L800M23K 600 P( )L36060(C)U64E1 (3) 3/0 WG 500 kcmil l or Cu LSIG 6.0P 800 P( )L36080(C)U64E P( )L36100(C)U64E L1200P25K 1200 P( )L36120(C)U64E1 (4) 3/0 WG 500 kcmil l or Cu 250 P( )L36025(C)U3E1 400 P( )L36040(C)U3E L800M23K 600 P( )L36060(C)U3E1 (3) 3/0 WG 500 kcmil l or Cu LSI 5.0H 800 P( )L36080(C)U3E P( )L36100(C)U3E L1200P25K 1200 P( )L36120(C)U3E1 (4) 3/0 WG 500 kcmil l or Cu 250 P( )L36025(C)U4E1 400 P( )L36040(C)U4E L800M23K 600 P( )L36060(C)U4E1 (3) 3/0 WG 500 kcmil l or Cu LSIG 6.0H 800 P( )L36080(C)U4E P( )L36100(C)U4E L1200P25K 1200 P( )L36120(C)U4E1 (4) 3/0 WG 500 kcmil l or Cu For 2P and 4P information see Catalog 0612CT0101. To complete the catalog number, replace the ( ) with the appropriate interrupting rating (G, J, K or L). For 100% rated circuit breakers add a C in the 9 th character place. For example, the catalog number for a 100% trip unit with LI trip functions at 250 would be PGL36025CU31. For all L interrupting rating, change the 5 th character (voltage rating) from a 6 (600V) to a 4 (480V); for example, PLL34025U31. The 480V IR is standard 100 k. Micrologic Interchangeable Harmonic Trip Unit a b c d Table.54: P-Frame Termination Options Table.55: P-Frame and R-Frame Interrupting s Termination Letter P-Frame Interrupting R-Frame Interrupting Voltage F = No Lugs (Includes terminal nut kit on both ends) G J K L G J K L For factory-installed termination, place L = Lugs both ends termination letter in the third block of 240 Vac 65 k 100 k 65 k 125 k 65 k 100 k 65 k 125 k M = Lugs ON end, terminal nut kit OFF end the circuit breaker catalog number. 480 Vac 35 k 65 k 50 k 100 k 35 k 65 k 65 k 100 k P = Lugs OFF end, terminal nut kit ON end 600 Vac 18 k 25 k 50 k 25 k 18 k 25 k 65 k 50 k D = Drawouta P G L U 4 1 = I-Line (See Section 9) Termination Letter a For D pricing add termination pricing on page -45. R-frame catalog numbers and pricing page -28 Dimensions Page -55 Trip Unit Options Page -4 Optional Lugs Page -42 lternate Plugs Page -48 Enclosure Page -56 ccessories page -39 DE2 Discount -2

28 PowerPact Circuit Breakers Micrologic Interchangeable Standard Trip Unit R-Frame Circuit Breakers Class 612 / Refer to Catalog 0612CT Table.56: R-Frame 3000 (600 Vac, 50/60 Hz) 3Pa Circuit Breaker with Electronic Trip Unit Electronic Trip Unit Sensor bc Gbd Jbd Kbd Lbd Type Function Trip Unit 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated 80% Rated 100% Rated Basic Electronic Fixed 1200 R( )F36120 Trip Unit long-time, 1600 R( )F (Not djustable ET1.0I 2000 R( )F36200 Interchangeable) Instantaneous 2500 R( )F R( )F36060(C)U R( )F36080(C)U R( )F36100(C)U R( )F36120(C)U31 LI R( )F36160(C)U R( )F36200(C)U R( )F36250(C)U R( )F36300(C)U Micrologic Interchangeable mmeter Trip Unit Micrologic Interchangeable Power Trip Unit Micrologic Interchangeable Harmonic Trip Unit Note: a b c d 600 R( )F36060(C)U R( )F36080(C)U R( )F36100(C)U R( )F36120(C)U33 LSI R( )F36160(C)U R( )F36200(C)U R( )F36250(C)U R( )F36300(C)U R( )F36060(C)U R( )F36080(C)U R( )F36100(C)U R( )F36120(C)U41 LI R( )F36160(C)U R( )F36200(C)U R( )F36250(C)U R( )F36300(C)U R( )F36060(C)U R( )F36080(C)U R( )F36100(C)U R( )F36120(C)U43 LSI R( )F36160(C)U R( )F36200(C)U R( )F36250(C)U R( )F36300(C)U R( )F36060(C)U R( )F36080(C)U R( )F36100(C)U R( )F36120(C)U44 LSIG R( )F36160(C)U R( )F36200(C)U R( )F36250(C)U R( )F36300(C)U R( )F36060(C)U63E1 800 R( )F36080(C)U63E R( )F36100(C)U63E R( )F36120(C)U63E1 LSI 5.0P 1600 R( )F36160(C)U63E R( )F36200(C)U63E R( )F36250(C)U63E R( )F36300(C)U63E R( )F36060(C)U64E1 800 R( )F36080(C)U64E R( )F36100(C)U64E R( )F36120(C)U64E1 LSIG 6.0P 1600 R( )F36160(C)U64E R( )F36200(C)U64E R( )F36250(C)U64E R( )F36300(C)U64E R( )F36060(C)U3E1 800 R( )F36080(C)U3E R( )F36100(C)U3E R( )F36120(C)U3E1 LSI 5.0H 1600 R( )F36160(C)U3E R( )F36200(C)U3E R( )F36250(C)U3E R( )F36300(C)U3E R( )F36060(C)U4E1 800 R( )F36080(C)U4E R( )F36100(C)U4E R( )F36120(C)U4E1 LSIG 6.0H 1600 R( )F36160(C)U4E R( )F36200(C)U4E R( )F36250(C)U4E R( )F36300(C)U4E R-frame circuit breakers can be bus- or cable-connected. For cable connections, optional terminal pad kit RLTB or equivalent bus structure is required. Each RLTB kit contains terminal pads for one end of the circuit breaker only and has provisions for mounting a maximum of 8 lugs per phase (9 lugs for 3000 ). RLTB kits are included with % rated circuit breakers. The RL3TB kits are included with the 3000, 80% and 100% rated circuit breakers. For other circuit breakers, order terminal pad kit (RLTB) and optional lugs separately. See pages For 2P and 4P information see Catalog 0612CT0101. To complete the catalog number, replace the blank ( ) with the appropriate interrupting rating (G, J, K or L). Listed catalog numbers are for 80% rated circuit breakers. For 100% rated circuit breakers add a C in the 9 th character place. For example, the catalog number for a 100% standard trip unit with LI trip functions at 2500 would be RGF36250CU31. See page -2 for interrupting ratings table. -28 DE2 Discount

29 Motor Circuit Protectors PowerPact H- and J-Frame Electronic Motor Circuit Protectors Class 611 / Refer to Catalog 0611CT1001 PowerPact H- and J-frame electronic Motor Circuit Protectors (MCP) are magnetic-only instantaneous-trip circuit breakers. They are designed to offer short circuit protection and are National Electrical Code (NEC) compliant when installed as part of a combination controller having motor overload protection. MCP circuit breakers accept the same accessories and terminals as the equivalent thermal-magnetic circuit breakers. Determine the hp rating from the nameplate of the motor. Select a MCP with an ampere rating recommended for the hp and voltage involved. When using the automatic settings the MCP microprocessor automatically adjusts the trip settings for both current and time to align with the start-up characteristic for the motor type, whether it is a standard or energyefficient motor. This includes a dampening means to accommodate a transient motor inrush current without nuisance tripping of the circuit breaker. Standard Energy Efficient Energie Efficace Energia Eficiente Motor Type / Tipo de Motor / Type de Moteur t Standard Energy Efficient Energie Efficace Energia Eficiente Standard Energy Efficient Energie Efficace Energia Eficiente I Table.5: Frame Sensor H- and J-Frame Electronic Motor Circuit Protectors (MCP) Full Load mperes Range djustable Instantaneous Trip Range Suffix J (See SCCR Table Below) Interrupting L (See SCCR Table Below) M1 HJL36030M HLL36030M H-Frame M2 HJL36050M HLL36050M M3 HJL36100M HLL36100M M4 HJL36150M HLL36150M J-Frame M5 JJL36250M JLL36250M Table.58: Maximum or Setting of Motor Protective Devicesa Type of Motor Setting Percentage of Full-load Current Not to Exceedb, B, C, D Standard 800% 1300% B, E Energy Efficient 1100% 100% a Based on 2005 NEC Table b See NEC Exception No. 1 to Table The NEC 1300% maximum setting may be inadequate for instantaneous trip circuit breakers to withstand current surges typical of the magnetization current of autotransformer type reduced voltage starters, or open transition wye-delta starters during transfer from start to run, constant hp multi-speed motors, and motors labeled high efficiency. Table.59: MCP Selection by HP sc of Induction-type Squirrel-Cage and Wound-rotor Motorsd 3Ø 60 Hz Voltagese 200 Vac 230 Vac 460 Vac 55 Vac Full-Load mperes M M M M M5 c Based on 2005 NEC Table d Per NEC 430.3, part-winding motors should select two circuit breakers, each at not more than one-half the allowable trip setting for the horsepower rating. The two circuit breakers should operate simultaneously as a disconnecting means per NEC e Listed voltages are rated motor voltages. Corresponding system voltages are 200 Vac, Vac, Vac and Vac. Select wire and circuit breakers based on horsepower rather than nameplate full-load current per NEC () for general motor applications. Short Circuit Current (SCCR) Tested to meet NEC and UL508 requirements for short circuit current ratings as part of an approved combination controller. Table.60: Contactor/Starter Short Circuit Current s (SCCR) J Interrupting L Suffix Vac 480 Vac 600 Vac Vac 480 Vac 600 Vac Tesys D-line and F-line 100 k 65 k 25 k 125 k 100 k 50 k NEM Type S 100 k 65 k 25 k 125 k 100 k 50 k See for specific ratings and combination ID numbers. ccessories page -39 Optional Lugs Page -42 Dimensions Page -55 Enclosures Page -56 To select combination starters and motor controllers using MCP s meeting NEC rticle 430, refer to pages DE2 Discount -29

30 Motor Circuit Protectors H-Frame and J-Frame MCP Selector Class 611 / Refer to Catalog 0611CT Table.61: pplication of PowerPact H-Frame and J-Frame Electronic Motor Circuit Protectors (MCP) Horsepower of Induction-type Squirrel-cage and Wound-rotor Motors 3Ø 60 Hz NEC Full Load Starter Size 200 Vac 230 Vac 480 Vac 55 Vac mperes 1/ / / / / / / / / / / / / / / / Shaded area is not covered by J-frame electronic motor circuit protector. PowerPact H-Frame and J-Frame Electronic MCP HJL36030M1 and HLL36030M1 1/2 10 hp HJL36100M3 and HLL36100M hp JJL36250M5 and JLL36250M hp HJL36050M2 and HLL36050M hp HJL36150M4 and HLL36150M hp -30

31 Motor Protectors Motor Circuit Protectors and Motor Protector Circuit Breakers Class 580, 585, 680, 685 Motor Circuit Protector Motor Circuit Protectors Mag-Gard Motor Circuit Protectors (MCP) are instantaneous-trip magnetic-only circuit breakers. They have a single adjustment which simultaneously sets the magnetic trip level of each individual pole. Mag-Gard circuit breakers comply with NEC requirements for providing motor circuit protection when installed as part of a UL Listed combination controller having motor overload protection. Interrupting ratings are established for these UL Recognized Components only when they are used in combination with motor starters with properly sized overload relays and contactors. ll Mag-Gard circuit breakers will accept the same lugs and accessories as equivalent circuit breakers. Mag-Gard circuit breakers are available with I-Line construction.i High-interruption (H) construction Mag-Gard circuit breakers (LHL) are also available. Table.62: mpere LL 400 Magnetic Only 3 Pole, 600 Vac, 50/60 HziThree Device Solutionsg Trip Unit djustablef Trip Range () Vdc Multiplier High = 1.2 Low = 1.4 LL M LL M LL M LL M LL M LL M LL M LL M For PowerPact L- and P-Frames, an instantaneous-only version of the electronic trip circuti breaker is also available for motor circuit protection. These MCPs comply with NEC requirements for providing short-circuit protection when installed as part of a Listed combination controller having motor overload protection. Motor Protector Circuit Breaker Table.63: f g h i Sensor PowerPact L-Framei PowerPact PJL, PLLi Magnetic Only 3 Pole, 600 Vac, 50/60 HziThree Device Solutionsg Trip Unit djustablef Trip Range () Interrupting G J L R M % LGL36400M3X LJL36400M3X LLL36400M3X LRL36400M3X % LGL36600M3X LJL36600M3X LLL36600M3X LRL36600M3X PJL36060M PLL34060M PJL36080M PLL34080M PJL36100M PLL34100M PJL36120M PLL34120M UL magnetic trip tolerances are -20%/+30% from the nominal values shown. Three-device solutions are the traditional solutionss: motor circuit protector plus motor starter plus overload relay. 250 Vdc ratings are available. No UL component recognition These electronic magnetic only motor circuit protectors are available with I-Line constructions. Consult the factory. Table.64: Electronic Trip Unit Type Frame Motor Protector Circuit Breakers Motor protection circuit breakers provide built-in thermal and magnetic protection. They are used in two-device motor feeder solutions to provide protection against short-circuits, overloads, and phase unbalance. H-Frame (150 ), J-Frame (250 ) and L-Frame (600 ) Electronic Motor Protector Circuit Breakers (UL s) Two Device Solutionsj Sensor Trip Unit Full Load mperes Range (FL) Isd (x FL) Interrupting G J L R x FL HGL36030M38X HJL36030M38X HLL36030M38X HRL36030M38X x FL HGL36050M38X HJL36050M38X HLL36050M38X HRL36050M38X H-Frame M x FL HGL36100M38X HJL36100M38X HLL36100M38X HRL36100M38X Standardk x FL HGL36150M38X HJL36150M38X HLL36150M38X HRL36150M38X J-Frame x FL JGL36250M38X JJL36250M38X JLL36250M38X JRL36250M38X x FL LGL36400M38X LJL36400M38X LLL36400M38X LRL36400M38X L-Frame 2.3 M x FL LGL36600M38X LJL36600M38X LLL36600M38X LRL36600M38X j Two-device solutions (these electronic motor protector circuit breakers include short circuit and overload protection) 1 electronic motor circuit protector with a Micrologic 2.2 M plus 1 contactor k The standard trip unit offers Class 5, 10 and 20 and phase unbalance or phase loss protection. ccessories page -39 and Supplemental Digest Pages Optional Lugs......Page -42 and Supplemental Digest Pages Dimensions Pages -54 and -55 Enclosures Page -56 To select combination starters and motor controllers using MCP s meeting NEC rticle 430, refer to pages DE2 Discount -31

32 Motor Circuit Protectors H-, J-, and L-Frame MCP Selection Class djustable instantaneous-trip circuit breakers are intended for use in combination with motor starters with overload relays for the protection of motor circuits from short circuits. Other specific applications include rectifiers and resistance welders. These circuit breakers contain a magnetic trip element in each pole with the trip point adjustable from the front. Interrupting ratings are determined by testing the instantaneous-trip circuit breakers in combination with a contactor and overload relay. Select instantaneous-trip circuit breakers as follows: This selection table is suitable for motors, other than NEM Design E, with locked-rotor indicating code letters per NEC Table 430. (b) as follows: Table.65: Locked-Rotor Indicating Codes Horsepower 1/2 or less 3/4 to 1-1/2 2 to 3 5 to to or more Motor Code letter L K J H G F 1. For other motors order a special thermal-magnetic circuit breaker with magnetic trip settings for the specific motor specify motor horsepower, voltage, frequency, full-load current and code letter or locked rotor current. 2. Determine motor hp rating from the motor nameplate. 3. Refer to the tables and select an instantaneous-trip circuit breaker with an ampere rating recommended for the hp and voltage involved. 4. Select an adjustable trip setting of at least 800%, not to exceed 1300%, of the motor full-load amperes (FL) for other than Design E motors. For Design E motors, select an adjustable trip setting of at least 1100% not to exceed 100% of FL. 5. The NEC 1300% maximum setting may be inadequate for instantaneous-trip circuit breakers to withstand current surges typical of the magnetization current of autotransformer type reduced voltage starters, or open transition wye-delta starters during transfer from start to run, constant hp multi-speed motors, and motors labeled high efficiency. Select thermalmagnetic circuit breakers from page -33 for those applications. 6. Part-winding motors, per NEC 430.3, should have two circuit breakers selected from the above at not more than one half the allowable trip setting for the horsepower rating. The two circuit breakers should operate simultaneously as a disconnecting means per NEC Based on NEC and NEC Table See page -31 for available djustable Instantaneous-Trip Circuit Breakers. Table.66: Hp s of Induction Type Squirrel-Cage and Wound Rotor Motors 200 Vac 230 Vac 3Ø 60 Hz 460 Vac PowerPact H-Frame and L-Frame Motor Protector Circuit Breaker 55 Vac Full Load mperesa PowerPact Family Motor Protector Circuit Breaker b Magnetic Trip Settingsc MIN MX H( )L36030M38X H( )L36030M38X 15 1 H( )L36030M38X H( )L36030M38X H( )L36030M38X -1/ H( )L36030M38X -1/ H( )L36030M38X H( )L36050M38X H( )L36050M38X H( )L36050M38X H( )L36050M38X H( )L36050M38X H( )L36050M38X H( )L36050M38X H( )L36050M38X H( )L36100M38X H( )L36100M38X H( )L36100M38X H( )L36100M38X 500% 1300% H( )L36100M38X L( )L36400M38X L( )L36400M38X L( )L36400M38X L( )L36400M38X L( )L36400M38X L( )L36400M38X L( )L36400M38X L( )L36400M38X L( )L36400M38X L( )L36600M38X L( )L36600M38X L( )L36600M38X L( )L36600M38X L( )L36600M38X L( )L36600M38X L( )L36600M38X L( )L36600M38X Table.6: Hp s of Induction Type Squirrel-Cage and Wound Rotor Motors 200 Vac 230 Vac 3Ø 60 Hz 460 Vac LL djustable Instantaneous-Trip Circuit Breakers for Single Motor Circuit Protection 55 Vac Full Load mperesa Mag-Gard Circuit Breaker Magnetic Trip Settingsc MIN MX LL M 00% 1400% LL M 00% 1500% LL M 00% 1400% LL M 00% 1400% LL M 00% 1400% LL M 00% 1400% LL M 00% 1300% LL M 600% 1300% a Motor full-load currents are taken from NEC Table Select wire and circuit breakers on basis of horsepower rather than nameplate full-load current per NEC () for general motor applications. Do not use these values to select overload relay thermal units. See Digest pages for selection of thermal units when actual full load current is not known. The voltages listed are rated motor voltages. Corresponding nominal system voltages are , , and V. b To complete catalog number, replace the blank with the appropriate rating (G, J, or L). M38X is for standard trip units. For advanced trip units (LCD display, metering and communication, replace with M58X). c Only MIN and MX settings are shown, intermediate settings are available on all circuit breakers. d See NEC () for circuit breaker settings above 800%. e If due to motor starting characteristics, trip settings at the 1300% maximum permitted level are needed, the next size Mag-Gard circuit breaker should be chosen. -32

33 Motor Circuit Protectors Table.68: Motor Protection Selection Tables Class 601 Selection Tables for Conductors, Safety Switches and Thermal-Magnetic Circuit Breakers Based on 2005 NEC Tables , & a 8 XHHW requires 3/4 in. conduit for 3W. b200 V motors are commonly used on 208 V services. cordinary service for normal starting duty only, acceleration time of 10 sec. or less. dheavy service is jogging or plugging duty or cycling load with over 25 starts per hour or over 5 starts per minute. Energy efficient motors are polyphase motors defined in NEM Standard MG1 and exhibit high starting current. enec for Single Motor, Smaller conductors may be permitted for light duty-cycle service per (B) Exception No. 1. DC motors operating from rectified 1Ø power supply will require larger conductors per () Exception No. 1. For motor-generator arc welders, see fmotor full load currents thru 200 hp are taken from NEC Tables , 148 and 150. bove 200 hp from UL 98. Select wire size, circuit breakers, or fuses on basis of hp rather than nameplate full load current per NEC Do not use these values to select overload relay thermal units. See Digest pages for selection of thermal units when actual full load current is not known. Voltages listed are rated motor voltages. Corresponding nominal system voltages are V, V, V, V and V. gswitch size only is shown in table. Selected fuses should not exceed maximum percent of full-load current as given in NEC Table bove 50 hp dc switches are not hp rated by UL as Motor Circuit Switches, but as General Use Switches only and are not necessarily capable of interrupting the max. operating overload current of a motor. See NEC 100 for definition of General Use Switch. When protecting a 3Ø, Design E energy efficient motor, the switch is required by NEC to have a hp rating of not less than 1.4 times that of a motor rated hp, or not less than 1.3 times that of a motor rated over 100 hp. Switches shown in this table do not necessarily comply with that requirement. hthermal-magnetic circuit breaker ampere ratings recommended are approximate for average conditions, based on trip characteristics of Square D circuit breakers and NEC Table Under some conditions, the next size larger switch or circuit breaker rating may be necessary to accommodate the motor starting current and is permitted by NEC (C)(1) Exception 2. High starting currents are anticipated with Design E and other energy efficient motors. For explanation of Code letter markings, see NEC 430.(B). For Busway Plugin units, see page 9-. ithermal-magnetic breaker ampere ratings recommended are approximate for average conditions and based on trip characteristics of Square D circuit breakers and NEC Tables 430.(B) and jtype LC, LI, LX, LXI, and LE circuit breakers are NOT recommended for use on single motor branch circuits. Contact your local Field Office for circuit breaker selection on constant horsepower multi-speed motors. Squirrel-Cage and Wound- Rotor Motors with Norm. Torque Characteritics Operating at usual Speeds 3Ø 60 Hz Horsepower s 1Ø 10 Hz ac verage Direct Current Motors Operating at Base Speed Full Load mperagef 200 Vacb Vac Vac 55 Vac 115 Vac 200 Vacb Vac Vdc 240 Vdc 3/ / / / / / / / / / / / mperage of Thermal- Magnetichj Inverse Time Circuit Breaker For Motor Code Letter B to E Ordinary Heavy Service Servicec and Energy Efficientd For Motor Code Letter F to Vi / / / / / QMB and Heavy Duty Switch with Time Delay Fusesg Minimum Size metallic Conduit 5 C, C Wire Field- Installed Sized for 125% FLe WG kcmil Conduit 3 W THHN THWN XHHW 14 1/2 in. N/ 12 1/2 in. N/ 10 1/2 in. N/ 8 1/2 in.a N/ 6 3/4 in. 1 in. 4 1 in. 1 in in. 1-1/4 in / in. 1-1/4 in /4 in. 1-1/2 in /0 1-1/4 in. 1-1/2 in /0 1-1/2 in. 1-1/2 in /0 1-1/2 in. 2 in /0 2 in. 2 in in. 2 in in. 2-1/2 in /2 in. 2-1/2 in in. 3 in (2) 3/0 (2) 2-1/2 in. (2) 2 in (2) 4/0 (2) 2 in. (2) 2 in (2)300 (2) 2 in. (2) 2-1/2 in (2) 350 (2) 2-1/2 in. (2) 2-1/2 in (3) 300 (3) 2 in. (3) 2-1/2 in THW -33

34 utomatic Switches Class 600 / Refer to Catalog 0612CT utomatic molded case switches open instantaneously at a factory preset magnetic trip point, calibrated to protect only the molded case switch itself, when it is subjected to high fault currents. The trip point is nonadjustable and provides no overload or low level fault protection. Molded case switches open when the handle is switched to the OFF position or in response to an auxiliary tripping device such as a shunt trip. ll molded case switches will accept the same lugs and accessories as equivalent thermal-magnetic circuit breakers, with the exception of Q-frame switches which do not have electrical accessories available. utomatic molded case switches are UL Listed per UL 489 and are CS Certified. J-Frame Switch L-Frame Switch Table.69: H-Frame, J-Frame, and L-Frame PowerPact utomatic Molded Case Switches, 600 Vac Circuit Breaker Poles mpere G Withstand L Withstand R Withstand Terminal Wire Range Trip Point Trip Point Trip Point 150 HGL26000S15a HLL26000S L150HD 14 WG 3/0 WG l/cu 2 15 JGL26000S JLL26000S L15JD 4 4/0 WG l/cu H-Frame 250 JGL26000S JLL26000S L250JD 3/0 WG 350 kcmil l/cu J-Frame 150 HGL36000S HLL36000S L150HD 14 WG 3/0 WG l/cu 3 15 JGL36000S JLL36000S JRL36000S L15JD 4 4/0 WG l/cu 250 JGL36000S JLL36000S JRL36000S L250JD 3/0 WG 350 kcmil l/cu 400 LGL36000S40X LLL36000S40X LRL36000S40X L150HD 3 L600LS52K3 600 LGL36000S60X LLL36000S60X LRL36000S60X L250JD (2) 2/0 WG 500 kcmil l/cu L-Frame 400 LGL46000S40X LLL46000S40X LRL46000S40X L150HD 4 L600LS52K4 600 LGL46000S60X LLL46000S60X LRL46000S60X L250JD (2) 2/0 WG 500 kcmil l/cu a True 2P device. Others are a 2P in a 3P module. Table.0: Q-Frame (240 Vac) PowerPact utomatic Molded Case Switches J Withstand Circuit Breaker Poles mpere Wire Range Trip Point QBL22000S22c Q-Frameb 4 WG 300 kcmil QBL32000S22c b Withstand rating of 10 k at 240 Vac. c DE2 discount schedule. Table.1: P-Frame and R-Frame PowerPact utomatic Molded Case Switchese, 600 Vac Frame Poles mpere J Withstand K Withstand L Withstand Terminal Wire Range Trip Point Trip Point Trip Point 600 PJL26000S k PKL26000S k PLL24000S60d k L800M23K (3) 3/0 WG 500 kcmil 800 PJL26000S k PKL26000S k PLL24000S80d k l or Cu PJL26000S k PKL26000S k PLL24000S10d k L1200P25K (4) 3/0 WG 500 kcmil 1200 PJL26000S k PKL26000S k PLL24000S12d k l or Cu P 600 PJL36000S k PKL36000S k PLL34000S60d k L800M23K (3) 3/0 WG 500 kcmil 800 PJL36000S k PKL36000S k PLL34000S80d k l or Cu PJL36000S k PKL36000S k PLL34000S10d k L1200P25K (4) 3/0 WG 500 kcmil 1200 PJL36000S k PKL36000S k PLL34000S12d k l or Cu 1200 RKF26000S k RLF26000S k 2 For cable connections, RLTB kit or R 1200 RKF36000S k RLF36000S k equivalent bus structure is required RKF36000S k RLF36000S k Kit is included with 3000 switches RKF36000S k RLF36000S k For all others, see page RKF36000S k RLF36000S k 3000 RKF36000S k RLF36000S k d P-frame L-interrupting is available in 480 Vac only. e UL magnetic trip tolerances are -20% / +30% from the nominal values shown. Table.2: H-, J-, L- P-, and R-Frame Withstand sf Withstand Voltage G J K L R 240 Vac 65 k 100 k 65 k 125 k 200 k 480 Vac 35 k 65 k 50 kg 100 k 200 k 600 Vac 18 k 25 k 50 kg 50 k 100 k f The withstand rating is the fault current at rated voltage that the molded case switch will withstand without damage when protected by a circuit breaker with an equal continuous current rating. g R-frame withstand is 65 k RKF26000S k RLF26000S k 2000 RKF26000S k RLF26000S k R-frame circuit breakers can be 2500 RKF26000S k RLF26000S k bus-connected or cable-connected. ccessories Page -39 and Supplemental Digest Pages Optional Lugs Page -42 and Supplemental Digest Pages Dimensions Pages -54 and -55 Enclosures Pages DE2 DE2 Discount

35 500 Vdc Circuit Breakers UL Listed 500 Vdc Circuit Breakers Class 500, 600 The UL Listed thermal-magnetic molded case circuit breakers shown below are specifically designed for use on ungrounded dc systems having a maximum short-circuit voltage of 500 Vdc or a maximum floating (unloaded) voltage of 600 Vdc. The circuit breakers are suitable for use only with UPS (uninterruptable power supplies) and ungrounded systems. This two-level voltage rating allows these circuit breakers to be applied to battery sources having a short-circuit availability of 20,000 amperes for LH, and MH circuit breakers and 25,000 amperes for PF circuit breakers at 500 Vdc. LH and MH circuit breakers are provided with an adjustable magnetic trip that is readily accessible by means of a single adjustment on the face of the circuit breaker. PF circuit breakers have a fixed magnetic trip range. These circuit breakers are UL Listed for the interrupting ratings shown only if applied with three poles connected in series (series connection is external to circuit breaker). See diagram below. NOTE: Due to external series connection, I-Line circuit breakers are not available for this application. CUTION/PRECUCION/ TTENTION Connect only as shown/conectar solo asi/ Francher seulement comme suit: 300 V 300 V MX. MX. Load/Carga/ Charge or o ou 600 V MX. Load/Carga/ Charge Source = 600 Vdc max. (floating) 500 Vdc max. (loaded) DC Circuit Breaker Label CUTION/PRECUCION/ TTENTION Connect only as shown/conectar solo asi/ Brancher seulement comme suit: 600 V MX. + + Load/Carga/ Charge or o ou V MX. Source = 600 Vdc max. (floating) 500 Vdc max. (loaded) MHL DCH Breaker Only 600 V MX. - Load/Carga/ Charge Table.3: DC Molded Case Circuit Breakers djustable Magnetic Trip Range mpere Circuit Breaker DC mperesa 500 Vdc Low High 100 JGL3100D JGL3125D k IR 150 JGL3150D JGL315D JGL3200D JGL3225D k IR JGL3250D LHL DC LHL DC k IR 350 LHL DC LHL DC MHL DC MHL DC MHL DC MHL360035DC k IR MHL DC MHL DC MHL DC MHL DCb k IR MHL DCH MHL DCH MHL DCH MHL360035DCH k IR MHL DCH MHL DCH MHL DCH MHL DCHb k IR a Magnetic trip tolerances are -20%/+30% from the nominal values shown. b Suitable for use only in a ventilated enclosure. Minimum enclosure dimensions are 38" h x 20" w x " d with a minimum of 300 square inches of ventilation near the top and bottom of the enclosure. mpere Circuit Breaker Fixed Magnetic Trip RangeDC mperesa Hold Trip 500 Vdc 1200 PF361200DC PF361600DC k IR PF362000DC PCF362500DC k IR ccessories page -39 and Supplemental Digest Pages Optional Lugs Page -42 and Supplemental Digest Page 3-29 Dimensions Page -55 and Supplemental Digest Page 3-33 Enclosures Pages DE2 Discount -35

36 500 Vdc Circuit Breakers UL Listed 500 Vdc NW Circuit Breakers Class 500, Masterpact NW DC Circuit Breaker Table.4: mpere Masterpact NW DC Circuit Breakers Circuit Breaker Interrupting 500 Vdc (max 600 Vdc unloaded) Fixed Circuit Breaker Drawout Circuit Breaker Cradle Version C Version C1 Version C Version C1 Version C Version C1 800 NW08NDC 35 k NW12NDC 35 k NW16NDC 35 k NW20NDC 35 k NW25NDC 35 k NW30NDC 35 k NW40NDC 35 k NW08HDC 85 k NW12HDC 85 k NW16HDC 85 k NW20HDC 85 k NW25HDC 85 k NW30HDC 85 k NW40HDC 85 k DE2 Discount

37 Mission Critical Circuit Breakers Selective Coordination 208 Y/120 V 3 Phase Panel Designed for selectively coordinated systems, mission critical circuit breakers maximize continuity of the electrical service by allowing the branch circuit breaker to clear the fault. PowerPact D-Frame Mission Critical Circuit Breaker Mission critical circuit breakers are engineered with technology that optimizes current, time and energy selectivity QO 20 1P QO 100 2P Load FULT Load so the fault is cleared by the circuit breaker immediately upstream of the occurrence. This technology (see figure below) allows the remaining areas of the electrical system to continue operation without disruption. In addition to unique design attributes, Square D mission critical circuit breakers have also undergone rigorous testing procedures to certify the coordination with downstream circuit breakerscombining innovative engineering with validated test results. pply Square D mission critical circuit breakers in emergency power distribution systems, data centers, hospitals or anywhere continuity of service is desired. The PowerPact J- and L-Frame Mission Critical circuit breakers deliver high levels of selective coordination in a flexible design that can be easily configured for a variety of applications. Tested to be selectively coordinated with the QO family of miniature circuit breakers and the ED, EG, and EJ circuit breakers, this solution provides peace of mind when power availability is critical. n electronic trip unit provides adjustable long-time settings in four sensor sizes, allowing coverage from 0 through 600 on a , 208Y/120, 240, 480Y/2, and 480 V systems Table.5: s UL 489 Listed CS Certified Voltage: 480 V PowerPact J- and L-Frame Mission Critical Circuit Breakers vailable Configurations I-Line mounting Main circuit breaker in NQ and NF panelboards Unit mount for OEM users Plug-in base for OEM users Drawout base ofr OEM users Table.6: J-Frame 250 Electronic Trip Mission Critical Circuit Breakers (480/2 Vac) with Factory Sealed Trip Units Suitable for Reverse Connectiona Electronic Trip Trip Unit Type Function Trip Unit Continuous D Interrupting G Interrupting J Interrupting L Interrupting Current Terminal Standard LI 3.2 W 250 JDL34250WU31X JGL34250WU31X 42. JJL34250WU31X 668. JLL34250WU31X L250JDb Standard LSI 3.2S-W 250 JDL34250WU33X JGL34250WU33X JJL34250WU33X JLL34250WU33X L250JDb High Perf. mmerter LSI 5.2-W 250 JDL34250WU43X JGL34250WU43X JJL34250WU43X 99. JLL34250WU43X L250JDb High Perf. Energy LSI 5.2E-W 250 JDL34250WU53X JGL34250WU53X JJL34250WU53X JLL34250WU53X L250JDb High Perf. mmerter LSIG 6.2-W 250 JDL34250WU44X JGL34250WU44X 256. JJL34250WU44X JLL34250WU44X L250JDb High Perf. Energy LSIG 6.2E-W 250 JDL34250WU54X JGL34250WU54X 861. JJL34250WU54X JLL34250WU54X L250JDb a Standard rated (80%). Not available in 100% rated. b L250JD terminal wire range is (1) 3/0 WG 350 kcmil l or Cu. Table.: L-Frame 600 Electronic Trip Mission Critical Circuit Breakers (480/2 Vac) with Factory Sealed Trip Units Suitable for Reverse Connectiona Electronic Trip Trip Unit Type Function Trip Unit Continuous D Interrupting G Interrupting J Interrupting L Interrupting Current Terminal 480/2 Vac, 50/60 Hz, 3P 250 LDL34250WU31X LGL34250WU31X LJL34250WU31X LLL34250WU31X L400L61K3b Standard LI 3.3 W 400 LDL34400WU31X LGL34400WU31X LJL34400WU31X LLL34400WU31X LDL34600WU31X LGL34600WU31X LJL34600WU31X LLL34300WU31X L600LS52K3c 250 LDL34250WU33X LGL34250WU33X LJL34250WU33X LLL34250WU33X L400L61K3b Standard LSI 3.3S-W 400 LDL34400WU33X LGL34400WU33X LJL34400WU33X LLL34400WU33X LDL34600WU33X LGL34600WU33X LJL34600WU33X LLL34300WU33X L600LS52K3c High Perf. mmeter LSI 5.3-W LDL34400WU43X LDL34600WU43X LGL34400WU43X LGL34600WU43X LJL34400WU43X LJL34600WU43X LLL34400WU43X LLL34300WU43X L600LS52K3c High Perf. Energy LSI 5.3E-W LDL34400WU53X LDL34600WU53X LGL34400WU53X LGL34600WU53X LJL34400WU53X LJL34600WU53X LLL34400WU53X LLL34300WU53X L600LS52K3c High Perf. mmeter LSIG 6.3-W LDL34400WU44X LDL34600WU44X LGL34400WU44X LGL34600WU44X LJL34400WU44X LJL34600WU44X LLL34400WU44X LLL34300WU44X L600LS52K3c High Perf. Energy LSIG 6.3E-W LDL34400WU54X LDL34600WU54X LGL34400WU54X LGL34600WU54X LJL34400WU54X LJL34600WU54X LLL34400WU54X LLL34300WU54X L600LS52K3c 480/2 Vac, 50/60 Hz, 4P 250 LDL44250WU31X LGL44250WU31X LJL44250WU31X LLL44250WU31X L400L61K4b Standard LI 3.3 W 400 LDL44400WU31X 096. LGL44400WU31X 396. LJL44400WU31X LLL44400WU31X LDL44600WU31X 989. LGL44600WU31X LJL44600WU31X LLL44300WU31X L600LS52K4c 250 LDL44250WU33X LGL44250WU33X 195. LJL44250WU33X LLL44250WU33X L400L61K4b Standard LSI 3.3S-W 400 LDL44400WU33X 61. LGL44400WU33X LJL44400WU33X LLL44400WU33X LDL44600WU33X LGL44600WU33X LJL44600WU33X LLL44300WU33X L600LS52K4c High Perf. mmeter LSI 5.3-W LDL44400WU43X LDL44600WU43X LGL44400WU43X LGL44600WU43X LJL44400WU43X LJL44600WU43X LLL44400WU43X LLL44300WU43X L600LS52K4c High Perf. Energy LSI 5.3E-W LDL44400WU53X LDL44600WU53X LGL44400WU53X LGL44600WU53X LJL44400WU53X LJL44600WU53X LLL44400WU53X LLL44300WU53X L600LS52K4c High Perf. mmeter LSIG 6.3-W LDL44400WU44X LDL44600WU44X LGL44400WU44X LGL44600WU44X LJL44400WU44X LJL44600WU44X LLL44400WU44X LLL44300WU44X L600LS52K4c High Perf. Energy LSIG 6.3E-W LDL44400WU54X LDL44600WU54X LGL44400WU54X LGL44600WU54X LJL44400WU54X LJL44600WU54X LLL44400WU54X LLL44300WU54X L600LS52K4c a Standard rating (100%) for 250 and 400 only. Standard rating 80% for 600. b L400L61K3 terminal wire ranges are (1) #2 WG 500 kcmil l or (1) #2 WG 600 kcmil Cu. c L600LS52K3 terminal wire ranges are (2) 2/0 WG 500 kcmil l or Cu. Table.8: J-Frame Termination Options Termination Letter = I-Line (See Section 9) F = No Lugs (includes terminal nut kit on both ends)a L = Lugs both ends M = Lugs ON end Terminal Nut Kit OFF end P = Lugs OFF end Terminal Nut Kit ON end N = Plug-in b D = Drawout b S = Rear Connected b For factory-installed termination, place termination letter in the third block of the circuit breaker catalog number. H G L Termination Letter a dd TS suffix for circuit breaker without terminal nut kit. Plug-in Drawout Rear Connected b For N and D pricing, add termination pricing on page -45 to price. For S pricing, add termination pricing on page -41 to price. Table.9: H- and J-Frame Interrupting s Interrupting ccessories page -39 Voltage D G J L Optional Lugs Page -42 Dimensions Page Vac 25 k 65 k 100 k 125 k 480 Vac 18 k 35 k 65 k 100 k Enclosures Page -56 DE2 Discount -3

38 Mission Critical Circuit Breakers Selective Coordination L Mission Critical Circuit Breakers The L High Magnetic Withstand MC Circuit Breakers are designed to trip at a higher magnetic trip level (18 20 times handle rating) than typical molded case circuit breakers (MCCBs) (which trip at 5 10 times the handle rating). The high magnetic withstand value of these L circuit breakers allow the downstream branch circuit breaker to clear the fault. Table.80: mpere L-Frame400, Thermal-Magnetic, High Magnetic Withstand Circuit Breakers For Mission Critical Loads C Magnetic Level Factory Set Standard Interrupting High Interrupting Terminal Hold Trip Wire Range L/LH MC Circuit Breaker, 3P, 480 Vac LL34200MC LL34225MC LHL34200MC LHL34225MC L250LMC LL34250MC LHL34250MC LL34400MC LHL34400MC L400L (1) kcmil l (1) 3/0 WG 350 kcmil Cu (1) 1 WG 600 kcmil l or (2) 1 WG 250 kcmil l Table.81: L-Frame Interrupting Table LL LHL 240 Vac 42 k 65 k 480 Vac 30 k 35 k PowerPact Circuit Breakers with Micrologic Electronic Trip Units The advantages of being able to adjust the trip curve of a circuit breaker equipped with an electronic trip system are obvious. There are other advantages, such as being able to adjust or turn off the instantaneous trip function on some circuit beakers and models of trip units. ccessories supplemental Digest Pages Compression and PDC Lugs Supplemental Digest Page 3-30 Dimensions Page -54 Enclosures Page DE2 Discount

39 PowerPact Circuit Breaker ccessories Electrical ccessories Class 612 / Refer to Catalog 0612CT0101 Table.82: Electrical ccessories ccessory Description Rated Voltage uxiliary and larm Switches (OF, SD, SDE) H-, J-, L-, M-, P, and R-Frame Shunt Trip (MX) Undervoltage Trip (MN) a b c d e H-, J-, and L-Frame H-, J-, and L-Frame Time Delay Unit Standard Min Load = 100m with Provides circuit 24V breaker contact status. Note: The location of the accessory in the circuit breaker determines its function. Low Level Min Load = 1m with 24V Trips the circuit breaker from a remote location by means of a trip coil energized from a separate supply voltage circuit. Instantaneously opens the circuit breaker when the under-voltage trip supply voltage drops to a value between 35% and 0% of its rated voltage. Closing is allowed when the supply voltage of the undervoltage trip reaches 85% of rated voltage. Undervoltage trip with externally mounted adjustable time delay unit for UVR of 0.5, 0.9, 1.5, 3.0 seconds before circuit breaker trips Undervoltage trip with externally mounted nonadjustable time delay unit of 0.25 sec before circuit breaker trips. Factory- Installed Cat. Suffix H-, J-, and L-Frame H- and J-Frame L-Frame Field- Installable Field- Installable Factory Installed Cat. Suffix M-, P-, and R-Frame Field- Installable 1 auxiliary switch (OF) 1a1b S S S auxiliary switch (OF) 2a2b B 2x S x S B 2x S auxiliary switch (OF) 3a3b C 3x S C 3x S larm Switch (SD) 1a1b BC S S BC S Overcurrent trip switch (SDE) 1a1b BD S BD S OF Switch S Consisting of: SDE dapter S larm switch and Overcurrent trip switch BE x S BE 2x S Consisting of: OF Switch 2x S SDE dapter S uxiliary Switch/larm Switch/dapter (OF/SD/SDE) Kit S33801c One auxiliary switch (OF) 1a1b E S S E S Two auxiliary switches (OF) 2a2b F 2x S x S F 2x S auxiliary switches (OF) 3a3b G 3x S G 3x S larm Switch (SD) 1a1b BH S S BH S Overcurrent trip switch (SDE) 1a1b BJ S BJ e S Consisting of: OF Switch S SDE dapter S larm switch and Overcurrent trip switch BK x S BKe 2x S Consisting of: OF Switch 2x S SDE dapterd S SK S29384 S29384 SK S SL S29385 S29385 SL S S S29386 S29386 S S33661 C SC S SD S2938 S2938 SD S SH S29388 S29388 SH S SJ S29389 S29389 DC C DC C/DC C/DC Field-installable kit includes time delay module only. Order undervoltage trip separately. Discount schedule DE2F. P-frame drawout circuit breaker only. SDE dapter used for H- and J-frame only. Not available on electrically operated P-frame. 12 SN S29382 S29382 SN S SO S29390 S29390 SK S SU S29391 S29391 SK S SP S S SL S SV S29383 S29383 SL S SR S29393 S29393 S S SS S29394 S29394 SC S UK S29404 S29404 UK S UL S29405 S29405 UL S U S29406 S29406 U S UC S UD S2940 S UH S29408 S29408 UH S UJ S29409 S UN S29402 S UO S29410 S29410 UK S UU S29411 S29411 UK S UP S S UL S UV S29403 S29403 UL S UR S29413 S29413 U S US S29414 S29414 UC S S33680a S33680a S33680ab S33681a S33681a S33681ab S33682a S33682a S33682ab S33683ab 48 S29426a S29426a S33684ab S33685ab S2942a S2942a DE2 DE2F Discount -39

40 PowerPact Circuit Breaker ccessories Motor Operators and Rotary Handles Class 612 / Refer to Catalog 0612CT Table.83: Motor Operators for H-, J-, and L-Frame Circuit Breakers Factory Field--Installable Kit Description Rated Voltage Installed H-Framea J-Frame L-Frame 600 Suffix ML S29440 S31548 S M S29433 S31540 S C MD S S S Standard motor for electricallyoperated MF S circuit breakersd MH S29435 S31542 S MO S29436 S31543 S DC MV S2943 S31544 S MR S29438 S31545 S MS S29439 S31546 S Motor Operator Communicating motor for electricallyoperated circuit breakerse C NC S S S Mounting hardware S Locking device Ronis lock S S S Profalux lock S S S Mounting hardware plus Ronis lock S S Operations counter S dapter for I-Line circuit breaker S S Table.84: Spring-Charging Motors for Electrically-Operated P-Frame Circuit Breakers Description Rated Voltage Factory Installed P-Frame (For Field-replacement Only) Replacement Coils Suffix Spring Charging Motor c Opening/Closing Coil 48 ML S4391 S M S4395 S33661 C Standard motor for electricallyoperated MC S4396 S circuit breakers MF S4398 S33664 Factory-installed includes motor and opening/closing MO S4390 S33659 coils MV S4391 S33660 DC MR S4392 S MS S4393 S NL S4391 S N S4395 S33035 Communicating motor C NC S4396 S33036 mechanism for electrically Spring-charging operated circuit breakers NF S4398 S33038 Factory-installed includes Motor NO S4390 S33033 motor NV S4391 S33034 and opening/closing coils. DC NR S4392 S NS S4393 S33036 Table.85: Rotary Operated Handles Direct Mounted Door Mounted Device Description Factory Installed Suffix H- and J-Framea L-Frame P-Frame Field Installable Factory Installed Field Installable Suffix Factory Installed Suffix Standard black handle Handle only RD10 S RD10 S RD Two early-break and two early make switches RD Standard black handle with One early-break switch RD12 S S RD12 S S Two early-make switches RD13 S S RD13 S S Handle only RD20 S RD20 S Red handle on yellow bezel One early-break switch RD22 S S RD22 S S Two early-make switches RD23 S S RD23 S S MCC conversion accessory S S CNOMO conversion accessory S Standard black handle Handle only RE10 S RE10 S RE Two early-break and two early make Standard black handle switches with: RE Two early make switches RE13 S S RE13 S S Red handle on yellow bezel Handle only RE20 S RE20 S Rotary Handle Replacement Kit S Telescoping RT10 S RT10 S ccessories Key lock adapter S S Ronis S S Key locks Profalux KS5 B24 D4Z S S Ronis keylocks with 1 key S S Profalux keylocks with 1 key S S Indication uxiliary Switch One early-break switch S S Two early-make switches S S a Not available in H-frame 2P modules. b CP1 discount schedule. c DE2F discount schedule. d Factory and field-installed standard motor operators for H- and J-frame circuit breakers require the SDE switch and SDE adapter (both included). Factory and field-installed standard motor operators for L-frame circuit breakers require the SDE switch (included). e Installation requires BSCM with NSX Cord. SeeTable.118, page -49 for ordering information. Direct-Mounted handle Door-Mounted Handle -40 DE2F CP1 DE2 Discount

41 Table.86: Device Handle Padlocking Device Interlocking (Not UL listed) Key Locking a b c d PowerPact Circuit Breaker ccessories Locks, Interlocking Description Factory Installed Suffix Locks, Installation ccessories, and Rear Connections Class 612 / Refer to Catalog 0612CT0101 H- and J-Frame Q-Frame L-Frame M- and P-Frame R-Frame Field- Installed Field- Installed Field- Installed Factory Installed Suffix Field- Installed Factory Installed Suffix Field- Installed Removable (lock OFF only) S S S S Fixed (lock OFF or ON) YP S QBP.00 S YP S YP S Fixed (lock OFF only)a YQ S QBPF.00 NJPF YQ MPRPF YQ MPRPF Fixed (lock OFF only) 2P YQ H2PHL Mechanical for circuit breakers with rotary handlesa S S S Mechanical for circuit breakers with togglesa S QBMIK S Provision only, vertical mount, 1 or 2 locks Kirk J Provisions only, vertical mounting one key interlock including padlock provision, open position only. Kirk JEbd JEd Provision only, horizontal mount 1 lock, M- and P-frame 1 or 2 locks, R-frame Provision and 1 lock, vertical mount Provision and 1 lock, horizontal mount Kirk JK JK Ronis JBc JB Profalux JDc JD Kirk JG Kirk JL JL Ronis JCc JC Profalux JFc JF Provision and 2 locks keyed alike Kirk JN JN Provision and 2 locks keyed differently Kirk JP JP Not available in M frame or HD and HG 2P modules. Not available on M-frame. Not available for M, P or P frame drawout. Only available on P frame electronic. Not available on I-Line. Handle Rubber Boot Terminal Covers Removable Padlock ttachment Fixed Padlock ttachment Door Escutcheon Rear Connection Table.8: Description Installation ccessories fo H-, J-, and L-Frame Circuit Breakers H- and J-Frame L-Frame Field- Installed Field- Installed Front Panel Escutcheon for Toggle Breakers S Front Panel Escutcheon for Rotary Handle, Motor Operator, or extended escutcheon S S Phase Barriers (set of 6) S Handle Rubber Boote S S Sealing ccessories (for front cover screws) S S DIN rail mounting kit (requires 15 mm depth on a 35 mm DIN rail)e S DIN rail adapter Handle Extensions (set of 5) S S e Not available in HD and HG 2P modules. Table.88: Installation ccessories for M-, P-, and R-Frame Circuit Breakers Description Frame Field- Installed M-, P-Frame S3318f ccessory Cover R-Frame S Door Escutcheon Toggle Handle M-, P-Frame S Drawout P-Frame S3385f Short lug cover 3P S Terminal Covers Short lug cover 4P S P-Frame Long lug cover 3P S Long lug cover 4P S Standard R-Frame S Replacement Handle Standard Short M-, P-Frame S Long M-, P-Frame S f DE2F discount schedule. Table.89: Device Rear Connections Description Poles Factory- Installed Termination No. H-Frame J-Frame L-Frame Field- Installable Poles Factory- Installed Termination No. Field- Installed Poles Factory- Installed Field-Installed Termination No. Mixed Rear 2 S 2 S 3 S S Connection Kitg 3 S S S S S S Short rear connections (set of 2) 2x S3433h x S3438h x S43245h or 3 2 or 3 3 Long rear connections (set of 2) S S3439i x S43246h Consisting of: Short terminal cover (3P) 3 S S x S32562h Short terminal cover (4P) 4 4 2x S32563h g Kit contains 4 short rear connections, 2 long rear connections (4 long rear connections for 4P), hardware, and 2 terminal covers.. h Price shown is for quantity one. i For use with 3P circuit breakers only. DE2 DE2F Discount -41

42 PowerPact Circuit Breaker ccessories Mechanical Lugs Class 612 / Refer to Catalog 0612CT J-Frame Lug L-Frame Lugs Table.90: Description l Lugs for Use with l or Cu Wire Cu Lugs for Use with Cu Wire Only Mechanical Lug Kits for H-Frame and J-Frame Circuit Breakersa Circuit Breaker pplication mpere Number of Wires Standard mpere Optional Per Lug and Wire Range Kit Qty Per Kit Per Kit HD, HG, HJ, HL (1) 14 3/0 WG l or Cu L150HD JD, JG, JJ, JL (1) 4-4/0 WG l or Cu L15JD JD, JG, JJ, JL JD,JG,JJ,JL (1) 3/0 350 kcmil l or Cu L250JD HD,HG,HJ,HL (1) 14 2/0 WG Cu CU150HD JD,JG,JJ,JL (1) 1/0 300 kcmil Cu CU250JD Control Wire Terminal for H-frame lug kit S Control Wire Terminal for J-frame lug kit S a See page -44 for terminal nuts/bus bar connections. Table.91: Description l Lugs for Use with l or Cu Wire Cu Lugs for Use with Cu Wire Only Mechanical Lug Kits for L-Frame Circuit Breakers mpere Circuit Breaker pplication Poles Unit Mount I-Line Number of Wires Per Lug and Wire Range Kit Qty Per Kit Per Kit X X (1) 2 WG 500 kcmil l L400L61K X (1) 2 WG 600 kcmil Cu L400L61K /600 3 X L600LS52K (2) 2/0 WG 500 kcmil l or Cu 4 X L600LS52K /600 3 X X (2) 3/0 WG 500 kcmil l or Cu L600LF52K /400 3 X X CU400L61K (1) 2 WG 600 kcmil Cu 4 X CU400L61K /600 3 X CU600LS52K (2) 2/0 WG 500 kcmil Cu 4 X CU600LS52K /600 3 X X (2) 3/0 WG 500 kcmil Cu CU600LF52K M- and P-Frame Lugs (800 and below) P-Frame Lugs (bove 800 ) Table.92: Description l Lugs for L or Cu Wire Cu Lugs for Cu Wire Onlyg Mechanical Lug Kits for M-Frame, P-Frame and R-Frame Circuit Breakerse Circuit Breaker pplication Standard Optional mpere Wires per Lug and Wire Range Lugs Per Kit Per Kit L800M23K (3) 3/0 WG-500 kcmil L800M23K PG, PJ, PL, MG, MJ 800 (4) 3/0 WG-500 kcmil L1200P24Kb M-, P-Frame L800P6Kb PG, PJ, PL, MG, MJ 800 (2) 3/0 WG-600 kcmil L800P6K4b PG, PJ, PL, MG, MJ 800 (2) 3/0 WG-50 kcmil L800PKb kcmil: compact L only L800PK4b L1200P25Kc PG,PJ, PL 800 (4) 3/0 WG-500 kcmil L1200P25K4c P-Frame L1200P6KUc PG, PJ,P L (3) kcmil L1200P6KU4c PG,PJ,PL PG, PJ, PL 1200 (3) 3/0 WG-50 kcmil L1200PKUc kcmil: compact L only L1200PKU4c I-Line (4) 3/0 WG-600 kcmil L1200R53K R-Frame 2500 Unit Mount (1) 3/0 WG-50 kcmil L2500RKd PJ (1) 1-1/0 WG CU250P1Kf CU800M23K M-, P-Frame 800 MG, MJ, PG, PJ, PL (3) 3/0 WG-500 kcmil CU800M23K MG, MJ, PG, PJ, PL (4) 3/0 WG-500 kcmil CU1200P24Kb CU1200P25Kc P-Frame 1200 PG, PJ, PL (4) 3/0 WG-500 kcmil CU1200P25K R-Frame 1200 I-Line (4) 3/0 WG-500 kcmil CU1200R53K b Does not fit onto ON end of unit-mount P-frame circuit breakers. c For unit-mount circuit breaker only. d ll unit-mount R-frame circuit breakers require terminal pads for mounting lugs of any type. See page -44. e For lug with a tapped hole for control wire, add a T before the K in the catalog number (for example, L800P6TK). f This lug can only be used on low amp PJ frame breakers where the Instantaneous setting must not be turned OFF. The cables must be laced with rope per lug instructions. g Not available with tapped hole for control wire. -42 DE2 Discount

43 PowerPact Circuit Breaker ccessories Compression Lugs and Power Distribution Connectors (PDC) Class 612 / Refer to Catalog 0612CT0101 Table.93: Description Compression Lug Kits for PowerPact Circuit Breakers Circuit Breaker Type mpere System Range Mounting Type Dimension (in) Max. Lugs per Terminal Compression Lug Kits for H-Frame and J-Frame Circuit Breakers WG l or Cu Y060HD luminum H-frame 150 1/0 4/0 WG l or Cu Y150HD Compression Lug Kits /0 WG l or Cu Y150JD J-frame 250 3/0 350 kcmil l or Cu Y250J Unit/I-linec /0 WG Cu CY060HD Copper H-frame /0 WG Cu CY150HD Compression Lug Kits /0 WG Cu 0. 1 CY150JD J-frame J-Frame Compression Lugs 250 2/0 300 kcmil Cu CY250J Compression Lug Kits for L-Frame Circuit Breakers kcmil l/cu Y400L31K kcmil l/cu Y600L32K /0-500 kcmil l/cu 1 Y400L51K /0-500 kcmil l/cu 2 Y600L52K luminum kcmil l 500 kcmil Cu 1 Y400L1K Compression L-frame Unit/I-linec Lug Kits kcmil l/cu 1 Y400L31K kcmil l/cu 2 Y600L32K /0-500 kcmil l/cu 1 Y400L51K /0-500 kcmil l/cu Y600L52K kcmil l 500 kcmil Cu Y400L1K /0-300 kcmil Cu CY400L31K /0-300 kcmil Cu CY600L32K kcmil Cu 1 CY400L51K Copper kcmil Cu 2 CY600L52K Compression L-frame Unit/I-linec Lug Kits 250 2/0-300 kcmil Cu 1 CY400L31K /0-300 kcmil Cu 2 CY600L32K kcmil Cu 1 CY400L51K kcmil Cu 2 CY600L52K Compression Lug Kits for M-Frame, P-Frame, and R-Frame Circuit Breakers 250 2/0-300 kcmil 3. 2 Y250P /0-500 kcmil Y300P M-, P-frame 400 2/0-300 kcmil Y400P Unit/I-linec kcmil 3. 2 Y400P /0-500 kcmil Y600P P-Frame Compression Lug Kit luminum kcmil Y800P Compression Lug Kits /0-300 kcmil Y1200R /0-500 kcmil I-linec Y1200R R-framea kcmil Y1200R /0-300 kcmil a 8 Y2000R /0-500 kcmil Unitc a 8 Y2000R kcmil a 8b Y2500R /0-500 kcmil CY400P Copper M-, P-frame 600 4/0-500 kcmil Unitc CY600P R-Frame Compression Lug Kit Compression kcmil CY800P Lug Kits /0-500 kcmil CY1200R R-frame I-Linec kcmil CY1200R a ll unit-mount R-frame circuit breakers require terminal pads for mounting lugs of any type. See page -44. b 9 lugs for 3000 circuit breakers c Not for use on I-Line circuit breakers unless wire bending space is adequate. Table.94: Power Distribution Connectors for H-Frame, J-Frame and L-Frame Circuit Breakerse PDC6HD6 PDC3HD2 PDC6JD4 PDC3JD20 Use with Circuit Breaker Type Circuit Breaker mpere Wires Per Terminal & Wire Range Dimension (in.) Qty. Per Kit Qty. Per Kit Per Kit Per Kit (6) 14 6 WG Cu 1.0 PDC6HD HD, HG, HJ, HLd (3) 14 2 WG Cu 1.2 PDC3HD (6) 14 4 WG Cu 1.0 PDC6JD JD, JG, JJ, JLd (2) 14 1 WG and (1) 3 2/0 WG Cu 1.5 PDC3JD (3) 14 1 WG and (2) 3 2/0 WG 1.28g PDC5DG20L LD, LG, LJ, LL (12) 14 4 WG 1.31g PDC12DG4L d OFF end only when OFF end is the load end. e Not for use with I-Line circuit breakers. PDC12P4 PDC6P20 Crimp lug or PDC connectors extension past end or circuit breaker See Table Table.95: f g Power Distribution Connectors for M-Frame and P-Frame Circuit Breakersf Use for multiple load connections on one circuit breaker in place of standard distribution block to save space and time. Use on load end of circuit breaker only Use in UL508 Industrial Control applications only. Use in UL1995/CS C22.2 No. 236 heating and cooling equipment. For Cu wire only. mpere (Wires Per Terminal) Wire Range Qty Per Kit Per Kit (6) 12 2/0 WG Cu PDC6P (6) 12 2/0 WG Cu PDC6P PDC12P (12) 10 4 WG Cu PDC12P Not for use with I-Line circuit breakers. Kit includes long terminal shield and cover, which adds 1.65 inches to standard lug with short terminal shield. Extremity of Molded Case w/mechanical Lugs See Table DE2 Discount -43

44 PowerPact Circuit Breaker ccessories Terminal Nuts, Terminal Pads, Terminal Shields and ccessories Class 612 / Refer to Catalog 0612CT Terminal Nut Insert Table.96: Terminal Nuts for Bus Bar Connection of H-Frame and J-Frame Circuit Breakers Description Frame Tap Qty Per Kit Per Kit H-Frame Terminal Nut Insert English HD/HG/HJ/HL 1/4-20 S H-Frame Terminal Nut Insert English HD/HG/HJ/HL 1/4-20 S H-Frame Terminal Nut Insert Metric HD/HG/HJ/HL M6 S J-Frame Terminal Nut Insert English JD/JG/JJ/JL 1/4-20 S J-Frame Terminal Nut Insert English JD/JG/JJ/JL 1/4-20 S J-Frame Terminal Nut Insert Metric JD/JG/JJ/JL M8 S Control Wire Terminal for H-Frame Terminal Nut HD/HG/HJ/HL S Control Wire Terminal for J-Frame Terminal Nut JD/JG/JJ/JL S H-Frame Lug With Terminal Nut Table.9: Bus Bar Connections Hardware for L-Frame, M-Frame and P-Frame Circuit Breakers Frame Description Term. No. Poles L-Frame Set of 4 terminal screws and washers for one side F 4 S M- and P-Frame Bus Connector Kit for one pole, one end 1 S H-Frame Short Lug Shield RLTB Terminal Pad Kit Phase barrier or terminal shield extension past end of circuit breaker B See Table Extremity of Molded Case w/mechanical Lugs J-Frame Short Lug Shield R-Frame Phase Barrier Table.98: Terminal Pad Kits for R-Frame Circuit Breakers Terminal Pad Kit Field-Installable Kits R-Frame Circuit Breaker Lugs per 3P Kit (One End Only) 4P Kit (One End Only) Usage Phase. 3000, 100% Rated Required for cable or bus 9 RL3TB RL3TB , Standard (80% Rated) Required for cable or bus 2500, 100% Rated Required for cable or bus 2500, Standard (80% Rated) Required for cable, optional for bus 8 RLTB RLTB ll Other R-Frame CIrcuit Breakers Required for cable, optional for bus For cable connection to RLTB, use L2500RK lug. See page -43. Table.99: Used With Terminal Shields and Phase Barriers Description Dimension B (in.) Qty Per Kit Frame Max. Wire Size H- and J-Frame Short Lug H-Frame 60 3 WG 0.50 S Mechanical Lugs Shielda H-Frame 150 3/0 WG 0.50 S J-Frame 350 kcmil 0.24 S Compatible with: Compression Lugs PDC H- and J-Frame luminum Copper Power Distribution Connectors and H-Frame Long PDC6HD6 Y060HD CY060HD Compression Lugs Lug Shield PDC3HD2 Y150HD CY150HD 2.24 S J-Frame Long Lug PDC6JD4 Y150JD CY150JD Shield PDC3JD2 b CY250J S M-, P-Frame S Phase Barriers 3 R-Frame S a Short lug shields provide IP20 protection for mechanical lugs and are compatible with control wire terminals. b J-frame terminal shield is not compatible with the Y250J35 compression terminal. B See Table Table.100: Miscellaneous H-, J-, and L-Frame Circuit Breaker ccessories ccessory Description Field-Installed Cat. No, Bag of screws for accessory cover, L-frame S Spare Parts 1 spare toggle extension, L-frame Set of 10 identification labels LV c DE5 Discount -44 DE2 Discount

45 H-Frame and J-Frame Plug-in Mounting L-Frame Plug-In Mounting L-Frame Disconnecting Blocks PowerPact Circuit Breaker ccessories H-Frame and J-Frame Drawout Mounting L-Frame Drawout Mounting P-Frame Drawout Cradle Connections L-Frame Locking Device b c Needs 2 kits per cradle. Discount DE2F Plug-In and Drawout Mountings Class 611, 612 / Refer to Catalog 0611CT1001, 0612CT0101 Table.101: Plug-In and Drawout Mountings for H- and J-Frame Circuit Breakers (3P or 2P in a 3P module) Complete Factory-ssembled Circuit Breakers Special Order Options for Plug-In and Drawout Circuit Breakers ccessories for Plug-In and Drawout Description Factory Installed Field- Installed Plug-in base shipped with circuit breaker N Drawout cradle shipped with circuit breaker D Plug-In Base Circuit breaker Only HJ Plug-in base kit S Circuit breaker only HJ Plug-in base kit S Drawout Cradle Cradle side plates (fixed part of chassis) S Circuit breaker side plates (moving part of chassis) S H-Frame Shutter Kit (set of two) S J-Frame Shutter Kit (set of two) S Fixed part 9-wire connector (mounted on Secondary base) S Disconnect Blocks Moving part 9-wire connector (mounted on circuit breaker) S Support for 2-moving connectors S Extended escutcheon with extended toggle handle S Two position indicating switches (connected/disconnected) S H-Frame Short Terminal Cover (3P S J-Frame Short Terminal Cover (3P) S Table.102: Plug-In and Drawout Mountings for L-Frame Circuit Breakers Description Poles Factory Installed Plug-in Mounting Field- Installed Factory Installed Drawout Mounting Field- Installed Kit (stationary and moving parts) 3 N D N D S S Plug-in base Stationary Part 4 S S Fixed part of chassis S Circuit breaker only HJ HJ Moving part of chassis S Moving Part 3 2x S x S Short terminal covers 4 2x S x S a Price shown is for quantity of 1. Table.103: Plug-In and Drawout ccessories for L-Frame Circuit Breakers Field- Description Installed Fixed Part 9-wire connector S Secondary Disconnecting Blocks Moving Part 9-wire connector S Support for 3 moving connectors S Fixed + Moving 9-wire manual auxiliary connector S Shutters Two shutters for plug-in base Extended escutcheon for toggle S Chassis ccessories Locking device (key lock is not included) S Two position indicating switches (connected/disconnected) Table.104: Termination Options Termination Letter For factory-installed termination, place N = Plug-in termination letter in the third block of the D = Drawout circuit breaker catalog number. L G L U 3 1 X Termination No. Table.105: Drawout Cradle and ccessories for P-Frame Circuit Breakers Description Drawout Cradle Product Selector Cradle Front Connected Flat (FCF) SFCF12bc Connectors Rear Connected T Horizontal/Vertical (RCTH/RCTV) SRCTV12bc Modbus cradle communication module S Safety shutters S48933c Secondary disconnects terminal shield S3363c Cradle position switch 1a/1b Form C Connected/test/disconnected S3310c Low level cradle position switch 1a/1b Form CConnected/test/disconnected S3311c Cell keying kit S336c 9.00 Disconnected position key lockingprovision for Kirk or Federal Pioneer Lock S332c Cradle Door interlock kit S3386c ccessories Racking interior kit S3388c Door escutcheon (for replacement only, included with circuit breaker) S3385c Transparent cover S33859c Push-in terminal kit (3 wires) S33098c Push-in terminal kit (6 wires) S33099c Finger cluster S33166c Cluster grease (12 oz. tube) S48899c DE2 DE2F Discount -45

46 Micrologic Electronic Trip Units PowerPact H-, J-, and L-Frame Micrologic Trip Units Micrologic Standard Trip Unit Micrologic mmeter and Energy Trip Unit PowerPact H-, J-, and L-frame molded case circuit breakers may be specified with any of the following Micrologic Electronic Trip Units. Micrologic Standard 3.2/3.3 Trip Units True RMS sensing LI, LSI trip configurations Field-interchangeable trip units LED long-time pickup and trip indication Test kits available Thermal imaging Micrologic mmeter 5.2/5.3/6.2/6.3 Trip Units Includes all features listed for Micrologic standard trip unit, as well as: dvanced user interface Neutral protection Incremental fine tuning of settings Up to 12 alarms Digital ammeterphase and neutral (4-pole only) Phase loading bar graph Maintenance indicators including contact wear, number of operations, operating hours, and load profiles Cause of trip information for troubleshooting assistance LCD Display Zone-selective interlocking (ZSI) (short-time & ground-fault) Optional Modbus communicationspowerlogic compatible Micrologic Energy 5.2E/5.3E/6.2E/6.3E Trip Units Includes all features listed for Micrologic ammeter trip unit, as well as: Ground-fault trip with programmable ground fault alarm (available on 6.2E/6.3E only) Power and energy measurement Power quality measurements Current demand and power demand measurements Class 611 / Refer to Catalog 0611CT Table.106: Micrologic Trip Unitsi for PowerPact H-, J-, and L-Frame Circuit breakers x Standard Feature o vailable Option Features Standard mmeter Energy 3.2/3/3 3.2S/3.3S 5.2/ / E/5.3E 6.2E/6.3E LI x LSId x x x LSIG / Ground-Fault Tripe x x Ground-Fault larm/tripe x x Current Setting Directly in mperes x x x x x x True RMS Sensing x x x x x x UL Listed x x x x x x Thermal Imaging x x x x x x LED for Long-time Pickup x x x x x x LED for Trip Indication x x x x x x LED for Green Ready x x x x x x Up to 12 larms Used Together x x x x Digital mmeter x x x x Zone-selective Interlockingf x x x x Communications o o o o o o LCD Display x x x x Front Display Module FDM121 o o o o dvanced User Interface x x x x Neutral Protectione x x x x Contact Wear Indicationg x x x x Incremental Fine Tuning of Settings x x x x Load Profileg,h x x x x Power Measurement x x Power Quality Measurements x x d The LSI with 3.2S/3.3S trip units have fixed short time and long time delays. e Requires neutral current transformer on the three-phase four-wire loads f ZSI for H/J frames in only OUT. for L-frame ZSI is In and OUT. g Indication available using the communication system only. h % of hours in 4 current ranges: 0 49%, 50 9%, 80 89%, and >90% In. i DC not available with electronic trip units. Table.10: Micrologic Trip Unit Settings for H- and J-Frame Model Trip Function Trip Unit mpere Setting Standard LI LSI 3.2S mmeter LSI LSIG Energy LSI 5.2E LSIG 6.2E Table.108: Micrologic Trip Unit Settings for L-Frame Model Trip Function Trip Unit mpere Setting Standard LI LSI 3.3S mmeter LSI LSIG Energy LSI 5.3E LSIG 6.3E

47 Micrologic Electronic Trip Units PowerPact P- and R-Frame Micrologic Trip Units Table.109: Long-time Pickup Settings Class 612 / Refer to Catalog 0612CT0101 Plug Long-time Pickup Settings B C D E F G H Standard Trip Unit mmeter Trip Unit Power Trip Unit Harmonic Trip Unit djustable Plug PowerPact P- and R-frame molded case circuit breakers may be specified with any of the following Micrologic Electronic Trip Units. Micrologic (Standard) 3.0 and 5.0 Trip Units True RMS sensing LI, LSI trip configurations Field-interchangeable long-time rating plugs LED long-time pickup indication Test kits available Thermal imaging Micrologic (mmeter) 3.0, 5.0 and 6.0 Trip Units Includes all features listed for Micrologic standard trip unit, as well as: LSIG trip configurations Digital ammeterphase and neutral (4-pole only) Phase loading bar graph LED trip indication Zone-selective interlocking (ZSI) (short-time & ground-fault) Optional Modbus communicationspowerlogic compatible Micrologic (Power) 5.0P and 6.0P Trip Units Power measurement and advanced protection features includes all features listed for Micrologic ammeter trip unit, as well as: LSI trip configuration with programmable ground fault alarm LSIG (Ground-fault trip) with programmable ground fault alarm Incremental fine tuning of L, S, I, and G pickup and delay settings LCD dot matrix display and LED trip indication dvanced user interface dvanced protection IDMTLselectable long-time delay bands Neutral protection Power measurement Contact wear indication Modbus communicationspowerlogic compatible Local and remote settings Micrologic (Harmonic) 5.0H and 6.0H Trip Units Power quality measurement and advanced protection features. Includes all features listed for the Micrologic power trip unit, as well as: Enhanced power measurements functions Power quality measurements djustable Plugs for PowerPact P-Frame and R-Frame and Masterpact NT and NW Circuit BreakersSelection To provide maximum design flexibility, system protection, and field upgradeability, each Micrologic trip unit is equipped with an interchangeable long-time rating plug. Each trip unit requires an adjustable rating plug to determine the long-time pickup range of the circuit breaker. These plugs are factory installed on new trip units, or can be ordered separately for field-installable upgrades. djustable rating plugs are offered in eight different ranges of long-time pickup adjustments. The following chart show the ranges of adjustments. Each adjustment times the sensor rating (lr X In) of the circuit breaker sets the long-time pickup value of the circuit breaker. Table.110: Micrologic Trip Units x Standard Feature o vailable Option Features Standard mmeter Power Harmonic P 6.0P 5.0H 6.0H LI x x LSI (Instantaneous can be turned off) x x x x x x x LSIG / Ground-Fault Tripa x x x Ground-Fault larm (No Trip) ab x x Ground-Fault larm and Trip a x x djustable Plugs x x x x x x x x x True RMS Sensing x x x x x x x x x UL Listed x x x x x x x x x Thermal Imaging x x x x x x x x x Phase Loading Bar Graph x x x x x x x LED for Long-time Pickup x x x x x x x x x LED for Trip Indication x x x x x x x Digital mmeter x x x x x x x Zone-selective Interlocking x x x x x x x Communications o o o x x x x LCD Dot Matrix Display x x x x dvanced User Interface x x x x Protective Relay Functions x x x x Neutral Protection x x x x Contact Wear Indication x x x x Incremental Fine Tuning of Settings x x x x Selectable Long-time Delay Bands x x x x Power Measurement x x x x Power Quality Measurements x x Waveform Capture x x a Requires neutral current transformer in 3Ø4W systems. b Requires M2C or M6C Programmable Contact Module. Table.111: Micrologic Trip Unit and Options Model Protection dditional Features Field-Installable c Kit / Circuit Breaker dder 2.0 (IEC only) LSO S132R (UL/NSI only) LI None S LSI S (IEC only) LSO S142Rd (UL/NSI only) LI S141d mmeter 5.0 LSI S143d LSIG S144d P LSI S163de Metering, dv. Protection 6.0P LSIG S164de H LSI Metering, dv. Protection S13de H LSIG & Harmonic nalysis S14de c The standard rating plug supplied with a trip unit will be the rating plug. To specify an alternative adjustable rating plug, please add the letter designation to the end of the catalog number. Please refer to page -48 for a complete listing of adjustable settings available with each plug. (Example: S143B would specify a B rating plug instead of the standard "" plug.) Use suffix N if no rating plug is required, deduct $ from the complete trip unit kit price. d When replacing a standard trip unit with Type (mmeter), P (Power metering) or H (Harmonic analysis) trip unit, order the 12-pin connector kit S33101 for the Masterpact NW and NT and the PowerPact P-frame drawout circuit breakers or kit S33100 for PowerPact P-frame and R-frame unit-mount and I-Line circuit breakers. See page -48. e Requires Circuit Breaker Communications Module. f The LSI with 3.2S/3.3S trip units have fixed short time and long time delays. g Requires neutral current transformer on the three-phase four-wire loads h ZSI for H/J frames in only IN. for L-frame ZSI is In and OUT. i Indication available using the communication system only. j % of hours in 4 current ranges: 0 49%, 50 9%, 80 89%, and >90% In. Table.112: Special Options Description Factory-Installed Suffix Ship circuit breaker in closed position CT Characterization (Calibrated trip system) Field-Installable YK N/ N/C Q N/ DE2F Discount -4

48 Micrologic Electronic Trip Unit Full Function Test Kit Sensor Plug Trip Unit Seal Micrologic Trip Unit ccessories Class 612, 612/ Refer to Catalog 0611CT1001, 0612CT djustable rating plug "" is installed as standard on all Micrologic trip unit orders. However, an alternative Table.115: Trip Unit ccessories selection may be specified from the "ssembled" table Device Frame h below, and factory installed with your trip unit order at no Pocket Tester S additional charge. To order, please attach the appropriate UT Tester STRV catalog suffix to the end of the trip unit (after Spare UT Tester STRV specifying trip unit options). djustable rating plugs may BLuetooth/Modbus for UT Tester H/J/L SVW also be purchased as field-installable components from Spare Power Supply for UT Tester the table below Vac TRV Micrologic Cord for UT Tester TRV Table.113: Plugs Micrologic 5/6 Cover, Transparent S H/J Micrologic 2/3 Cover, Transparent S Factory-Installed Field-Installable Micrologic 5/6 Cover, Transparent S Pluga Cat. Suffix dder b L Micrologic 2/3 Cover, Transparent S (standard) N/C S LCD Display for Micrologic 5 S B B N/C S H/J/L LCD Display for Micrologic 6 S C C N/C S Hand-held Test Kit S D D N/C S Primary Injection Test daptor S E E N/C S Full-function dapter Kit S F F N/C S Full-function Test Kit P/R S G G N/C S Seven-pin Test Cable (for connection H H N/C S between test kit and trip unit)e S a Long-time pickup amperes (Ir) = Sensor (In) X Setting of rating Two-pin Test Cable (for connection plug. Fine adjustment tuning is included on Micrologic Power and between test kit and trip unit)f S Harmonic trip units, allowing for incremental settings of 1 between 230 Vac Filtered Power Cordg S the plug setting and.40 X Sensor. 120 Vac Filtered Power Cordg P/R S b DE2F Discount Trip Unit Battery for Trip Indicator Lights S Table.114: Neutral Current Transformers Power supply with: Vdc input For Use with Circuit Breaker Sensor 48/60 Vdc input S Vdc input H/J/L/P/R H-Frame S Vac input J-Frame S Vac input L-Frame S Vac input S3355c,d Micrologic Trip Unit Cover, clear S P-Frame S3356c,d Micrologic P/H Trip Unit Cover, P/R opaque gray S S48916c,d Trip Unit Seal (6 pieces) S34036c,d R-Frame for compliance with NEC 240.6(c) H/J/L/P/R MICROTUSEL S48896c,d pin Trip Unit Connector for S48182c,d NT/NW Masterpact Circuit Breakers S ll NCTWIRING ll pin Trip Unit Connector for P/R c DE2F Discount P- and R-Frame Circuit Breakers S33100i d Includes NCTWIRING kit. Battery Back-up (12 Hours) e Used for testing Micrologic trip units. Included in the price of the Handheld/Full-function Test Kits. Kit for replacement only. f Used for testing STR trip units. Included in the price of the Handheld/Full-function Test Kits. Kit for replacement only. g Included in the price of the Full-function Test Kit. Kit for replacement only. h DE2F Discount. i DE2 Discount. Table.116: Sensor Plugs for P- and R-Frame Circuit Breakersjm Circuit Breaker Sensor Plug Range Sensor Plug Catalog No. Circuit Breaker Frames ccepting Sensor Plug k P-Frame Circuit Breaker l l S4052 X S4053 X X X UL 600 S48823 X X X X S33092 X X X S33093 X X S48824 X S33091 X X X X X S33092 X X X X IEC 1000 S33093 X X X S33094 X X S33095 X R-Frame Circuit Breaker S48823 X X X X S33092 X X X X S33093 X X X X UL 1200 S48824 X X X X S33095 X X X X S33982 X X X S33983 X X S48825 X S33095 X X X X X IEC 2000 S33982 X X X X S33983 X X X S33984 X j For use only with circuit breakers with date codes later than k DE2F Discount. l IEC Only. m See rating plug for long-time pickup range on page DE2 DE2F Discount

49 Micrologic Electronic Trip Unit Table.11: Trip Unit Field-Installable ccessories for P- and R-Frame Circuit Breakers Description Factory-Installed Suffix dder Unit Mount I-Line Micrologic Trip Unit ccessories Class 611, 612 / Refer to Catalog 0611CT1001, 0612CT0101 Field-Installable Kit P-Frame Motor Operated Drawout With Rotary Handle Unit Mount Circuit Breaker Communication Module (BCM) (Modbus) E S64205 S64205 S6420 S64206 S64205 S64205 S Two Programmable Contacts Module (M2C) V S6423 S6423 S6423 S6423 S6423 S6423 S Six Programmable Contacts Module (M6C) W S64204 S64204 S64204 S64202 S64204 S64201 S External Voltage Sensing (EVS) YV S64203 S64203 S64210 S64209 S64210 S64208 S R-Frame I-Line Modbus Interface Module (IFM) Front Display Module (FDM) Breaker Status and Control Module (BSCM) NSX Cord for Modbus Communications Table.118: Trip Unit Field-Installable ccessories for H-, J-, and L-Frame Circuit Breakerse Description Factory-Installed Field-Installable Kit Suffix dder External ccessories Modbus Interface Module IFMa STRV Stacking Connections for IFM (10) TRV Front Display Module FDM121a STRV FDM Mounting ccessory (Dia. 22 mm) TRV Isolated Modbus Repeater Module STRV ZSI Interface Module S Internal ccessories NSX Cord b L = 1.3 m E S (for Modbus Communication) L = 3 m EB S BSCM (Breaker Status and Control L = 1.3 m EGf S434201BS Module) with NSX Cordb L = 3 m EHf S434202BS Replacement BSCM S NSX Cord for V > 480 Vacb L = 1.3 m ED S L = 3 m EE S BSCM with NSX Cord for V > 480 Vacb L = 1.3 m EKf S434204BS L = 3 m ELf S434303BS Vdc Terminal Block EN S SDTM 24/415 Vac/dc Modulec V S SDX Module 24/415 Vac/dcd V S a Require NSX Cord b Installation requires IFM (STRV00210) for Modbus communication and/or FDM (STRV00121) for external display c Remote indication relay for motor applications d Remote indication relay e For proper selection, see catalog 0611CT1001. f If using with motor operator requires communicating motor operator (suffix NC). SDTM Module (Remote indication relay for motor applications) ZSI Interface Module (Connects PowerPact H/J/L circuit breakers to PowerPact P/R and Masterpact NT/NW circuit breakers) Table.119: Wire Harnessg and ULP Cords for H-, J-, and L-Frame Circuit Breakers Description Factory-Installed Field-Installable Kit Suffix dderh ZSI Wire Harness, H/J Frame YH S ZSI Wire Harness, L-Frame YH S ENCT Wire Harness YH S OF Wire Harness YH S SD/SDE Wire Harness YH S SDx/SDTM Wire Harness YH S MN Wire Harness YH S MX Wire Harness YH S Vdc Terminal Block Wire Harnessi YH S Motor Operator Wire Harness YH S Communicating Motor Operator Wire Harness YH S NSX Wire Harnessi YH S ENCT and ZSI Wire Harness YH RJ45 Connectors female/female TRV ULP Line Terminations TRV RJ45/RJ45 Male Cords L = 0.3 m TRV L = 0.6 m TRV L = 1 m TRV RJ45/RJ45 Male Cords L = 2 m TRV L = 3m TRV RJ45/RJ45 Male Cord L = 5 m TRV g Wire harness is required for I-Line applications, optional for unit-mount applications YH1 = all installed accessories but ZSI and ENCT YH2 = ENCT and all installed accessories YH3 = ZSI and all installed accessories YH4 = ZSI, ENCT and all installed accessories h Price adder is for each accessory ordered. i I-Line wire harness is included for communication network accessories. Optional wire harness for unit mount requires YH1 suffix. DE2F Discount -49

50 Masterpact Universal Power Circuit Breakers Masterpact NT Masterpact NW Table.120: Masterpact NW Circuit Breaker s Masterpact NT/NW Circuit Breakers Class 613 / Refer to Catalog 0613CT The Masterpact universal power circuit breaker offers a family of circuit protection products meeting the most common world standards, NSI, UL and IEC. The basic design platform for each is common. The final result is UL, NSI and IEC circuit breakers with the same basic external dimensions, features and accessories. Full-Featured Performance Complete product offering up to 200 k IR without fuses Circuit breakers tested to show arc flash hazard risk category as referenced by NFP0E 800 to 6000 frames, fixed and draw-out Rated for C voltage systems through 600 V (635 V NSI) Short-time withstand ratings up to 100 k Cradle position indicator: connected, test and disconnected Simple, visual contact wear indicators Full complement of field-installable accessories common to all standards Four interchangeable Micrologic trip units to choose from vailable PowerLogic based power metering and monitoring capabilities vailable protective relay functions as defined by NSI C3.2 and C3.90 The following charts show the Masterpact NW and NT ratings for NSI and UL 489. See Pricing Guide 0613PL0001 and Catalog 0613CT0001. Standard NSI C3 Certified/UL 1066 Listed UL 489 Listed Frame /4000 f 4000/ /1200/1600/ / /5000/6000 Interrupting Code N1 H1 H2 H3 L1g L1Fg H1 H2 H3 L1g L1Fg H1 H2 H3 L1g H2 H3 L1g N H Lg LFg H Lg H Lg 240 Vac Interrupting Current (k RMS) 50/60 Hz 480 Vac Vac Short-time Withstand Current (k RMS) a 65a 30ab Built-in Instantaneous Override (k RMS ±10%) c c c 85 35c ab Close and latch rating (k RMS) d Tested to show the arc flash hazard risk category as referenced by NFP0E Yes Yes Yes Breaking time ms with no intentional delay (9 ms for L1, L1F, L and LF) Closing time 0 ms Sensor Endurance (C/O Cycles) Mechanical 12,500 10,000 10,000 5k 5,000 12,500e 10,000 5,000 With No Maintenance Electrical ,000 1,000 1k 1, e 1,000 1,000 a 24 k RMS for 800 circuit breaker frame with 100 or 250 sensor. b 65 k RMS for c None except 24 k RMS for 800 circuit breaker frame with 100 or 250 sensor. d 40 k RMS for e The endurance rating for 2000, N/H/L/LF is 10,000 for mechanical and 1000 for electrical. f 4000 standard width circuit breaker is not available in L1 interrupting rating code or drawout construction (fixed mounting only). g Drawout mounted only. Table.121: Masterpact NT Circuit Breaker s Interrupting Current (k RMS) 50/60 Hz Standard NSI C3 Certified/UL 1066 Listed UL 489 Listed Frame h Interrupting Code N1 N H L1 L LFi N H L1 L LFi N H L1 L 240 Vac Vac Vac N/ N/ Short-time Withstand Current (k RMS) Built-in Instantaneous Override (k RMS ±10%) Close and latch rating (k RMS) Tested to show the arc flash hazard risk category as referenced by NFP0E Yes Yes Breaking time ms with no intentional delay ms with no intentional delay (9 ms for L and LF) Closing time < 50 ms Sensor Endurance (C/O Cycles) With No Maintenance h Fixed-mounted only. i Drawout mounted only. Mechanical 12,500 12,500 12,500 12,500 Electrical NWMPRRT Table.122: Masterpact NW/NT Circuit Breaker Remote Racking Description Masterpact NW/NT Remote Racking Devicesj NWNTMPRRT Masterpact NW Remote Racking Devicej NWMPRRT Masterpact NT Remote Rackign Devicej NTMPRRT Mounting Bracket Kit for NW Remote Racking (contains 10 mounting brackets)k S Mounting Bracket Kit for NT Remove Racking (contains 10 mounting brackets)k S Control Unit for NW Remote Rackingk S ft Control Cable for NW Remote Rackingk S Drive Shaft for NW Remote Rackingk S Drive Shaft for NT Remote Rackingk S j Unit comes with 10 mounting brackets included. k For replacement only. -50 DE2F Discount

51 Ground-Fault Protection GC-200 Relay GCDSP Display T3B Toroid Sensor GT912 Rectangular Sensor GC-200 Ground-Fault Relay System Class 931, 940, 960 GC-200 Ground-Fault Relay System The GC-200 Ground-fault relay system protects a grounded distribution system from lowlevel arcing ground faults. The system includes the GC-200 relay, a sensor (current transformer), and optional GC DSP display and is used with a bolted pressure switch or circuit breaker to open a circuit upon detection of a ground fault. (Replaces GC-100 relay.) GC-200 Relay Features Five models with sensitivities suitable for main, feeder, or branch circuits Ten adjustable pickup settings for each model Small, non-metallic enclosure mounts on DIN rail 10 and 5 output contacts for trip and alarm Zone-selective interlocking (ZSI) to optimize coordinated systems I 2 t inverse time characteristics GCDSP Display (Optional) Real-time display of ground-fault values lso recalls ground-fault at last trip or at maximum since reset llows remote testing or resetting of the relay LCD back-lit display Surface mounts over panel meter cutout Fine adjust pickup settings (D and E versions only) Sensors Zero sequence sensing current transformers for all phases and neutral Several sizes of toroids and rectangular CTs Many are split-core or open frame for ease of installation Table.123: Ground-Fault Relay Description Specifications GC200C GC200D Ground-fault relay GC200E GCDSP Display module VW31104R10 1 m VW31104R30 3 m Display cable b VW31104R50 5m VW31104R m GC2DPTER dapter plate To replace GSDSP with GC2DSP a One GC12 twelve foot cable is included with GCDSP display modules. b Discount schedule CP4C Table.124: GC-200 Relay Settings djustable Pickup Settings (in mperes) GC200C GC200D GC200E Table.125: GC-200 Sensors Relay Cat. Sensor No. Type CT Window Dimensions Ratio in mm T2 Toroid 1.85 dia. 48 dia T3 Toroid 2.5 dia. 0 dia T6 Toroid 5.5 dia. 146 dia GC200C T6S Toroid, split-core 5.5 dia. 146 dia GC200D 1000:1 T9 Toroid 8.5 dia. 222 dia R13.5 x x R41 Rectangular 4.25 x x R826 8 x x ll "" type sensors above, plus: RZ : x x RZ :1 4.5 x x Rectangular, Open Frame RZ :1 4.5 x x RZ :1 4.5 x x RZ : x x RZ1021 Rectangular, Open Frame 1000: x x RZ : x x GC200E GT :1 5.5 x x GT918 Rectangular, Open Frame 600:1 5.5 x x GT :1 5.5 x x GT :1 8.5 x x GT1224 Rectangular, Open Frame 600:1 8.5 x x GT :1 8.5 x x GT :1 9.5 x x Rectangular, Open Frame GT :1 9.5 x x GT1530 Rectangular, Open Frame 600: x x DE2 Discount -51

52 Ground-Fault Protection RH99M P50 RH99P S200 Vigirex Ground-Fault Relay System Class 931, 840, Vigirex Ground-Fault Relay System The Vigirex ground-fault relays, with associated sensors (current transformers), measure the residual current in an electrical installation to detect levels which may be damaging. When used for protection, they cause an associated circuit breaker or switch to interrupt the supply of power to the protected system. They may also be used for monitoring only, with output to an alarm. The product line includes fixed sensitivities from 30 m to 1 and adjustable sensitivities up to 30. The Vigirex relays may be easily mounted on DIN rail or may be panel mounted in a meter cutout. Sensors for conductors range from a little more than an inch diameter toroids, to large rectangular sensors measuring 6 x 18 inches. The compact size of the relay and its sensor make it ideal for protection of OEM equipment as well as branch circuits. Table.126: Vigirex Ground-Fault Relays (UL 1053 Listed) Model Delay Reset Control Voltage Sensitivity DIN Rail Mounted RH10M Instantaneous Manual RH21M RH99M Panel Mounted a b c Instantaneous or 60 msec (2 settings) djustable (9 settings): 0, 0.06, 0.15, 0.23, 0.31, 0.5, 0.8, 1.0, 4.5 sec Manual Manual utomatic RH10P Instantaneous Manual RH21P RH99P Instantaneous or 60 msec (2 settings) djustable (9 settings): 0, 0.06, 0.15, 0.23, 0.31, 0.5, 0.8, 1.0, 4.5 sec Manual Manual utomatic 30 m m Vac/12 48 Vdc 300 m m m m Vac 300 m m m m Vac 300 m m Vac/12 48 Vdc Vac 30 ma or 300 m Vac (2 settings) Vac/12 48 Vdc 5630TD Vac djustable, 5632TD Vac (9 settings): 5633TD Vac/12 48 Vdc 0.03a, 0.1, 0.3, 0.5, 1, 56390TD Vac 3, 5, 10, TD Vac 56393TD 30 m m Vac/12 48 Vdc 300 m m mp m m Vac 300 m m mp m m Vac 300 m m Vac/12 48 Vdc Vac 30 ma or 300 m Vac (2 settings) Vac/12 48 Vdc 5640TD Vac 5642TD Vac djustable 5643TD (9 settings): Vac/12 48 Vdc 0.03a, 0.1, 0.3, 0.5, 1, 56490TD Vac 3, 5, 10, TD Vac 56493TD m is instantaneous only, except for RH99M and RH99P models. Their suffix TD indicates time delay at 30 m. For models with no time delay (IEC compliant) consult catalog 092CT0401. Table.12: Sensors for Vigirex Ground-Fault Relays Sensors Closed Toroids, Type Vigirex Sensor Iron Rings (Optional) Split toroids, Type O Type Maximum Currentc Inside Diameter in. mm T P I M S G T P I M POb GOb Rectangular Sensors 280 x x x x x x PO and GO are not UL recognized Use as a guideline for sizing wire through sensor. -52 DE2 Discount

53 Ground-Fault Protection Equipment dd-on Ground-Fault and Earth-Leakage Modules Class 931, 940, 960 GFM250 Optional GFM25CT Micrologic dd-on Ground-Fault Module (GFM) The Micrologic Ground-Fault Module (GFM) is a UL Listed/CS Certified circuit breaker accessory which protects equipment from damage caused by ground faults. It is an add-on module which, when connected to a PowerPact H- or J-frame thermal-magnetic circuit breaker only, provides ground-fault sensing and ground-fault relay functions. HD/JD ground-fault modules feature: djustable ground-fault pickup levels djustable ground-fault time delays Integral ground fault push-to-test feature Ground-fault indicator (mechanical for local, contacts for remote) ll GFMs are supplied for I-Line mounting as standard, easily convertible to unit mount by removing the I-Line bracket Fault-powered (through the sensing current transformer) for electronics, shunt trip, and integral test feature. Meets NEC (C) 12 Vdc shunt trip module (Catalog No. S29382) is required in the circuit breaker. This may be field installed or factory installed when the circuit breaker is ordered with an -SN suffix. UL 1053 Ground-fault Sensing and Relaying Equipment The GFM system requires the following: H-frame ( ) or J-frame ( ) molded case circuit breaker Shunt trip is required for the function of the GFM (may be factory-installed or field-installed) Bus bar connection (terminal nut inserts) for OFF end of circuit breaker Optional neutral current transformer, catalog number GFM25CT (must be ordered for 4-wire applications) NOTE: Ground-fault modules cannot be used for alarming only. Table.128: Module/Enclosure Selection Charta Companion Circuit Breaker Prefix b I-Line Switchboard Ground-fault Pickup djustment Range GFM HD, HG, HJ, HL GFM150HD L JD, JG, JJ, JL GFM250JD L ccessories H & J GFM25CT Optional Neutral Current Transformer (required for 4-wire loads) a t 250, the GFM250JD can be used with 80% rated circuit breakers only. b See Supplemental Digest page 3-3 for additional GFMs. I-Line J-Frame with ELM installed Earth Leakage Module (ELM) for PowerPact H- and J-Frame MCCBs The Earth Leakage Module (ELM) is an add-on module which, when connected to a PowerPact H- or J-frame MCCB, provides low-level ground-fault sensing and ground-fault relay functions. Because these ELMs are highly sensitive (30 m to 3 ), they provide much greater protection than GFMs (20 mps to 200 mps sensitivity). The ELMs provide greater protection of control circuits and other sensitive equipment. The associated circuit breaker must have a 48 Vdc shunt trip, which may be field-installed (kit S29392) or factory-installed (suffix SP) in the H- or J-Frame circuit breaker. dd-on Earth Leakage Module (ELM) Features: djustable ground-fault pickup levels as low as 30 m djustable ground-fault time delays from instantaneous to 500 msec (Time delay can be applied to the 30 m setting) Integral ground fault push-to-test feature Ground-fault indicator (LED for local status; contacts for remote indication) ll ELMs are supplied for I-Line mounting and are easily convertible to unit-mount by removing the I-Line brackets Three poles; 240 to 600 Vac maximum: 3-wire applications only (no neutral) Line-power obtained through internal bus to provide power for electronics, shunt trip, and integral test feature. shunt trip is required in the circuit breaker; it may be field-installed or factory-installed in the PowerPact H and J circuit breakers. UL 1053 Ground-fault Sensing and Relaying Equipment Table.129: ELM Selection Chartc c d Companion Circuit Breakerd Prefix Size Enclosure Space Required I-Line Switchboard Pick-Up djustment Range Catalog Number HD, HG, HJ, HL L 30 m 3 ELM150HD JD, JG, JJ, JL L 30 m 3 ELM250JD t 250, the ELM250JD can be used with 80% rated circuit breakers only. For Factory Installation of ELM Module: For termination designation (3rd letter of catalog number) use ONLY M. dd factory installed 48 Vdc shunt trip (suffix SP) to breaker plus suffix VL or VM. SP $1. adder. Use VL for H frame $436. adder. Use VM for J frame $4886. adder. Plus the List Price of the H or J breaker. DE2 Discount -53

54 Dimensions and Shipping Weights Figure 1 G B B E Figure 6 E G Figure 4 G B Figure 10 B E Figure 13 B Figure 1 B Figure 21 E B G F E B E B Figure 2 G E Figure B G B Figure 11 E Figure 14 B Figure 18 B B B B Figure 5 E Figure 8 G B E Figure 15 Figure 19 Figure 22 E B F C/L G B Figure 3 G E QOU, QYU Low mpere D C Figure 12 E B B Miniature and Molded Case Circuit Breakers QO, QOB D C QO-GFI, QO-PL QO-EPD D C F Figure 16 Figure 20 E F C/L Figure 9 QO-PLPS D C QOU High mpere D C E B E Figure 23 B G HH B F C60 D C C120 D C D C B Table.130: QO, QOU, Multi 9 Circuit Breakers FL, FHL FIL, KIL 2 & Q4L, LL, LHL 2 & LIL, LXIL 2 & g Dimensions E are 1.59 in at ON end and 0.63 in at OFF end. h Circuit Breaker Prefix QO, QOB QOB-VH 150 QOB-VH QO-PL QO-GFI QO-EPD QOU QYU Low mpere QOU High mpere Multi 9 C60 Poles Fig. No. DimensionsInches B C D E F G a a a b b b c d c d d f QO-PLPS Power Supply a 35 0 is 3.12 in; P and P are 3.50 in. b QO-PL is 4.55 in. c P and P are 4.45 in d P and P are 6.8 in. e in. f is 6.8 in. Table.131: QB, QD, QG, QJ, Q4, F, FI, KI, L, LI, LX, LXI Circuit Breakers Circuit Breaker Prefix Poles Fig. DimensionsInches No. B C D E F G H QB, QD, QG, QJ g g Table.132: Shipping Weightsh Frame Size pprox. Shipping Weight (Lbs.) Frame Size ll weights are for 3P circuit breakers unless otherwise noted. pprox. Shipping Weight (Lbs.) FL, FHL 1P 2 KIL 9 FL, FHL 2P 3 LL, LHL 15 FL, FHL 3P 5 LIL LXIL 25 FIL 8 Q4L 15 QB, QD, QG, QJ 4 E E B G Figure 24 D C E E F E -54

55 Dimensions and Shipping Weights Molded Case Circuit Breakers Figure 25 B F E Figure 26 G B G B E F C Figure 2 F C D D Table.133: HD, HG, HJ, HL, HR, JD, JG, JJ, JL, JR, LG, LJ, LL, and LR Circuit Breakers Circuit Breaker Prefix No. of Dimensions Poles Fig. No. Inches B C D E F G HD, HG, HJ, 2a HL, HR JD, JG, JJ, JL, JR LG, LJ, LL, LR a Only HD and HG are in 2P module, HJ, HL and HR 2P are in 3P module. Table.134: ED, EG, and EJ Circuit Breakers Circuit Breaker Prefix No. of Poles Fig. No. Dimensions Inches B C D E ED, EG, EJ ED, EG, EJ ED, EG, EJ GJ Table.135: MG, MJ, PG, PJ, PL, RG, RJ and RL Circuit Breakers E Figure 28 G Circuit Breaker Prefix MG, MJ (800 and below) PG, PJ, PK, PL ( ) No. of Poles Fig. No. Dimensions Inches B C D E F G 2, , RG, RJ, RL 2, C D Figure 29 Figure 30 Figure 31 B F Table.136: Shipping Weightsa Frame Size pprox. Shipping Weight (Lbs.) Frame Size pprox. Shipping Weight (Lbs.) HD, HG, HJ, HL 2P 4 JD, JG, JJ, JL, JR 5 HD, HG, HJ, HL, HR 3P 5 LD, LG, LJ, LL, LR ED, EG, EJ 1P 2 MG, MJ ED, EG, EJ 2P 3 PG, PJ, PK, PL 32 ED, EG, EJ 3P 4 RG, RJ, RK, RL (Without RLTB) 52 a ll weights are for 3P circuit breakers unless otherwise noted. E E B B E E B Figure 32 B C D E F E Figure 33 B G C D D C Figure 34 G B F D C E -55

56 Circuit Breaker Enclosures F100S F100RB F100DS Enclosures Class Circuit breaker enclosures are UL Listed, CS Certified and are suitable for use as service equipment except as footnoted. The short circuit rating of an enclosed circuit breaker is equal to the rating of the circuit breaker installed, except as footnoted. Circuit breakers are ordered and shipped separately for field installation. For enclosure accessories and dimensions refer to page -58. See Supplemental Digest page 3-35 for NEM and 9 enclosures for FL circuit breakers. Table.13: Circuit Breaker Enclosures Circuit Breaker Enclosure Prefix Poles NEM 1 Flush NEM 1 Surface NEM 3Ra FL, FHL, FCL , 2, 3 F100F F100S F100RB QBL, QDL, QGL, QJL Q22200NSb Q22200NRBb , 3 Q23225NFb Q23225NSb Q23225NRBb HDL, HGL, HJL, HLL , 3 JDL, JGL, JJL, JLL , 3 J250Fcde J250Scde J250Rcde HDL HD100Sfgcei JDL JD250Sigfce LL, LHL, Q4L , 3 L400F L400S L400R LL L400LSgiw MGL, MJL, PGL, PJL, PKL, PLL , 3 M800Sjk M800Rjm PGL, PJL, PKL, PLLl , 3 P1200Sk P1200Rm NEM 12/3R, 12K (HubsSee page 3-9) NEM 4, 4X, 5, 3, 3R Stainless Steel (HubsSee page 3-9) With Knockouts (NEM 12K) Without Knockoutsn (NEM 12/3R, 5) FL, FHL, FCL , 2, 3 F100DS F F100WK HDL, HGL, HJL, HLL , 3 JDL, JGL, JJL, JLL , 3 J250DScde J250WKcde KILq, KCL , 3 IK250DS IK250WK LL, LHL, Q4L , 3 L400DS L400WK LDL, LGL, LJL, LLL, LRL L600WKx LDL, LGL, LJL, LLL, LRL L600WKVWy LGL, LLL, LRL L600WKMCz MGL, MJL, PGL, PJL, PKL, PLL , 3 M800DSo M800WKo PGL, PJL, PKL, PLLl , 3 P1200WKo Nema r Cast luminum Nema 9u Cast luminum JDL, JGLstv , 3 J225X J225Y a Enclosures with NRB or RB suffix have provisions for 3/4 in. through 2-1/2 in. bolt-on hubs in top endwall. Enclosures with R suffix have blank endwalls and require field cut opening. For details and hub catalog numbers see page 3-9. b Not CS Certified. c ccepts standard rated 80% breakers. Not rated at 100%. d Maximum short circuit rating is 25 kir at 600 Vac, 65 kir at 480 Vac, 125 kir at 240 Vac. e Earth Leakage Module and Ground Fault Module are not compatible with these enclosures. f Maximum short circuit rating is 25 kir, 240 Vac. g Order service ground kit PKOGT2 if required. h Maximum short circuit rating is 18 kir, 480 Vac and 240 Vac. i Copper wire only. j When using a CT in the M800S and R enclosure the unit will no longer accommodate a 200% neutral solution. k CE certified per IEC , IP20D, PE type TN-C or TN-S l ccepts MGL or MJL standard rated (80%) breakers. ccepts PGL, PJL or PLL circuit breakers rated 80% (1200 maximum) or 100% rated breakers, (800 maximum). m CE certified per IEC , IP24D, PE type TN-C or TN-S n Suitable for rainproof NEM 3R application by removing drain screw from bottom endwall. o CE certified per IEC , IP56, PE type TN-C or TN-S p LEL 100% rated circuit breaker except for 600 sensor. q Short circuit rating is 100 k IR at 480 Vac maximum. r NEM Indoor Hazardous LocationsDivision 1 and 2, Class I, Groups C and D; Class II, Groups E, F,and G; Class III. s 80% rated circuit breakers only; SCCR Vac, Vac, Vac. t Not UL Listed due to wire bending space. u NEM 9Indoor Hazardous LocationsDivision 1 and 2, Class II, Groups E, F,and G; Class III. v Has a tapped 2-1/2 in. conduit opening on top and bottom end wall w Short circuit current rating is 30 k IR at 480 Vac. x Product also accepts PowerPact L Frame Motor Protector Circuit Breakers with suffix M38X. y Viewing Window factory installed. z Product accepts PowerPact L-Frame utomatic Molded Case Switches. 316 Grade Stainless Steel Circuit Breaker EnclosuresNEM 3, 3R, 4X, 5 and 12 Type 316 stainless steel circuit breaker enclosures offer superior corrosion resistance to a wider range of chemicals than Type 304 stainless steel enclosures. Type 316 better resists chloride and is often used in marine, waste treatment and transportation applications. Use watertight hubs from Section 3 page 10 of Digest 16. For other accessories reference Table.142 and Table.143. For dimensional information, reference Table.144. Table.138: 316 Grade Stainless Steel CIrcuit Breaker Enclosures Circuit Breakerab NEM 3, 3R, 4X, 5 and 12 Prefix...Suffix mpere Poles Enclosure HDL, HGL, HJL, HLL , 3 JDL, JGL, JJL, JLL , 3 J250SS MGL, MJL, PGL, PJL PKL, PLL , 3 M800SS Table.139: DC CIrcuit Breaker Enclosures for M and MH DC-Rated Circuit Breakers Circuit Breakerab NEM 1 Surface Enclosureaa Prefix...Suffix mpere Poles Enclosure ML, MHL , 3 M1200S aa UL Listed Only ab Use 500 Vdc or 250 Vdc rated circuit breakers only. ccessories Page -58 Dimensions Page DE1 DE2 Discount

57 Circuit Breaker Enclosures Enclosed Circuit Breaker Special pplications Class 610 Table.140: Enclosures for Walking Beam Manually Operated Mechanical Interlock Circuit Breakers (UL Listed)a a b c Prefix...Suffix Circuit Breaker NEM 1 Surfaceb NEM 3R bc mpere Poles Enclosure FL...WB, FHL...WB , 3 K250SWB K250RWB Catalog number in table is enclosure only. For complete installation, the following must be ordered separately: WB Circuit Breakers (qty. 2, Supplemental Digest page 3-2), Walking Beam ssembly (Supplemental Digest page 3-2), Mounting Pan (Supplemental Digest) page 3-2, Neutral (page -56) and Service Ground Kit (page -58). Enclosure has blank top endwall. For applications above 200 requiring a neutral, use copper wire only. Enclosed Motor-Operated Molded Case Circuit Breakers For information on Enclosed Motor-Operated Molded Case Circuit Breakers see the Supplemental Digest page Enclosure Enclosed Molded Case Switches For ordering information on molded case switches see page -34. For ordering information on enclosed molded case switches, see Supplemental Digest 15 Section Enclosed Walking Beam Mechanical Interlock NOTE: Contact local Field Office for catalog number prior to quoting or placing an order. Industrial molded case circuit breakers with walking beam mechanical interlocks are available in NEM 1 and 3R construction as completely enclosed device. Walking beam mechanical interlock is available manually operated or electrically operated using (2) 120 Vac motor operators. Not UL Listed. Enclosed walking beam mechanically interlocked circuit breaker. Specify circuit breaker catalog numbers Specify manually or electrically operated (electrically operated factory installed only) Specify enclosure type (NEM 1 or 3R) Specify if neutrals are required. (Same price) Table.141: Enclosed Walking Beam Mechanical Interlock Circuit Breaker Prefix (Standard Thermal- Magnetic Only) FL240 V 100 FL480 V 100 FL600 V 100 Manually Operated a Electrically Operated NEM 1 NEM 3R NEM 1 NEM 3R FHL600 V a Price includes (2) walking beam 3P circuit breakers, walking beam operator and mounting pan, (2) neutrals (if specified), and (2) motor operators (if specified) factory assembled in specified enclosure. b Not available factory assembled. Refer to page -56 for merchandise enclosure. NOTE: Contact local Field Office for catalog number prior to quoting or placing an order. -5

58 Circuit Breaker Enclosures Enclosure ccessories and Dimensions Class Table.142: Insulated Groundable Neutral ssembly Circuit Breaker Neutral ssembly For Use With Terminal Lug DataTotal vailable Prefix mpere NEM 1 & 3R NEM 4, 4X, 5, 12 & 12K NEM & 9 (Line plus Load) WG/kcmil Price FL, FHL, FCL 100 SN100F 2.00 SN100F 2.00 (4) 14 1/0 Cu or (4) 12 1/0 l F060X/Y(1) 14 6 Cu, plus (1) 14 4 Cu FL, FHL, FIL SN F100X/Y(1) 14 3 Cu, plus (1) 14 4 Cu HDL,HGL,HJL,HLL SN100F 2.00 SN100F 2.00 (4) 14 1/0 Cu or (4) 12 1/0 l HDL,HGL,HJL,HLL SN400L SN400L SN (2) or (4) l/cu, plus (2) l/cu JDL,JGL,JJL,JLL SN400L SN400L (2) or (4) l/cu, plus (2) l/cu FL...WB, FHL...WB 200 Requires (2) SN20 plus (1) SN20NI link ea plus ea (4) l/cu, plus (2) 14 1/0 l/cu LDL, LGL, LJL, LLL, LRL SN400L (2) or (4) l/cu, plus (2) l/cu SNC400LX (2) Cu, plus (2) 2 4/0 Cu LDL, LGL, LJL, LLL, LRL SN1000M (6) 3/0 500 l/cu, plus (1) 1 4/0 l/cu LDL, LGL, LJL, LLL, LRL SNC800LXc (4) Cu, plus (1) 2 4/0 Cu MGL, MJLd L800SN L800SN (6) 3/0 500 l/cu, plus (2) l/cu PGL, PJL, PKL, PLLe SN SN (8) 3/0 500 l/cu, plus (2) l/cu c ll Cu neutral assembly. d For NEM 1 and 3R 200% neutral applications order Jumper kit SN800SNI and 2 of kit SN1200. (No 200% neutral is available for NEM 4X or 12 devices.) e For applications with integral ground fault protection order Neutral Mounting Kit S3356MK and Neutral CT S3356 ( only). NEM Type 1 Q2, F, J, SWB L, MG, PG W W W Table.143: Service Ground Kits Circuit Breaker Prefix Ground Bar Number of Conductors Wire Range Terminals Per Terminal WG/kcmil Field-Installable Factory-Installed H QBL, QDL, QGL, QJL FL, FHL, FCL, FIL, FL...WB, FHL...WB KCL, KIL, LL, LHL, Q4L PKOGT2f /0 Cu or 6 2/0 l H HDL,HGL,HJL,HLL,JDL,JGL,JJL,JLL PKOGTJ l/cu LDL, LGL, LJL, LLL, LRL MGL, MJL PGL, PJL, PKL, PLL PKOGT l or Cu D f Quantity (2) required if ground wires are run in parallel. WB enclosure uses 2 circuit breakers NEM Type 3R Q2, F, L, MG, J, PG, RWB (uses side hinge cover) H D WB enclosure uses 2 circuit breakers NEM Type, Type 9 F, JDL, JGL W NEM Type 4, 4X, 5, 12, 12K IK, F, J, L, LX, MG, PG H D Table.144: Dimensions pproximate Dimension pproximate Dimension H W D H W D Series Series in. mm in. mm in. mm in. mm in. mm in. mm F100, WK E L400WK E F100DS E L400DS E F100F E L400F E F100RB E L400R E F100S E L400S E IK250WK E L400LS IK250DS E M800S / / HD100S M800R / / J250F M800DS 1 40-/ / / J250S M800SS 1 40-/ / / J250R M800WK 1 40-/ / / J250DS P1200S / / J250SS P1200R / / J250WK P1200WK / / JD250S Q22200NRB E J225X Q22200NS E J225Y Q23225NF E K250SWB E Q23225NRB E K250RWB E Q23225NS E L600WK L600WKVW L600WKMC See Supplemental Digest 3-3 and 3-38 for: Special paint Stainlee steel fronts Pilot lights, push buttons Lock-on SPL0 Key interlock systems Legend plates H W D -58 DE1 Discount

59 Photovoltaic Circuit Breakers and Switches 600 Vdc and 1000 Vdc PV Circuit Breakers and Switches Class 611 / Refer to Catalog 0611CT1302 The UL listed thermal-magnetic molded case circuit breakers and switches shown below are specifically designed for use in PV applications, rated at 50 C, offering grounded or ungrounded configurations. The products are fully tested and calibrated under the PV UL489B standard. The products come ready to install, including specially designed serial connectors for optimal thermal response, and adapted terminal covers for optimal isolation. Circuit Breakers come 100% rated for ease of use and selection. These two new frames are fully compatible with the current line of PowerPact accessories, from aux contacts and shunt trips to motor operators and rotary handles. Table.145: PV Molded Case Circuit Breakers 600 Vdc (3 poles) 1000 Vdc (4 poles) mpere Ungrounded Grounded Ungrounded Grounded Part Number Part Number Part Number Part Number 50 TGL36050L TGL36050K TBL41050L TBL41050K TGL36060L TGL36060K TBL41060L TBL41060K TGL3600L TGL3600K TBL4100L TBL4100K TGL36080L TGL36080K TBL41080L TBL41080K TGL36100L TGL36100K TBL41100L TBL41100K TGL36125L TGL36125K TBL41125L TBL41125K TGL36150L TGL36150K TBL41150L TBL41150K TGL3615L TGL3615K TBL4115L TBL4115K TGL36200L TGL36200K TBL41200L TBL41200K UGL36225L UGL36225K UCL41225L UCL41225K UGL36250L UGL36250K UCL41250L UCL41250K UGL36300L UGL36300K UCL41300L UCL41300K UGL36350L UGL36350K UCL41350L UCL41350K UGL36400L UGL36400K UCL41400L UCL41400K UGL36450L UGL36450K UCL41450L UCL41450K a N/... UGL36500G UCL41500J UCL41500G a % rated. Table.146: PV Circuit Breaker Max. Interrupting s Frame 600 Vdc 1000 Vdc T-Frame 10 k 3 k U-Frame 10 k 5 k Table.14: Circuit Breaker Numbering Brand Frame Termination Poles Voltage mperage Grounding Suffix Code Suffix Code T G L G B S Brand Blank: Schneider Electric Frame T: T-Frame U: U-Frame s B: 3 k C: 5 k G: 10 k Poles 3: 3P 4: 4P Voltage 6: 600 Vdc 1: 1000 Vdc Terminations L: Lugs Line/Load Side F: Bus Bar S: Rear Connected mperage 050: : 60 00: 0 080: : : : : : : : : : : : : 500 ccessory Suffix Cells (See Table.151 to Table.155) Grounding G: Grounded, 80% rated (500 Only) J: Ungrounded, 80% rated (500 Only) K: Grounded, 100% rated L: Ungrounded, 100% rated ccessory Suffix Cells (See Table.151 to Table.155) Table.148: PV Molded Case Non-utomatic Switches 600 Vdc (3 poles) 1000 Vdc (4 poles) mpere Ungrounded Grounded Ungrounded Grounded Part Number Part Number Part Number Part Number 100 TBL36000JZ TBL36000GZ TBL41000JZ TBL41000GZ TBL36000JZ TBL36000GZ TBL41000JZ TBL41000GZ TBL36000JZ TBL36000GZ TBL41000JZ TBL41000GZ UDL36000JZ UDL36000GZ UDL41000JZ UDL41000GZ UDL36000JZ UDL36000GZ UDL41000JZ UDL41000GZ UDL36000JZ UDL36000GZ UDL41000JZ UDL41000GZ UDL36000JZ UDL36000GZ UDL41000JZ UDL41000GZ Table.149: PV Switches Withstand s Frame 600/1000 Vdc T-Frame 3 k U-Frame.5 k Table.150: Switch Numbering Brand Frame Termination Poles Voltage mperage Grounding Trip System Suffix Code Suffix Code T D L G Z 1 0 B S Brand Blank: Schneider Electric only Frame T: T-Frame U: U-Frame s B: 3 k D:.5 k Poles 3: 3P 4: 4P Voltage 6: 600 Vdc 1: 1000 Vdc Terminations L: Lugs Line/Load Side F: Bus Bar S: Rear Connected mperage 000: Switch ccessory Suffix Cells (See Table.151 to Table.155) Trip System## (Z: Non-utomatic Switch) (##: merage ) Z10: 100 Z15: 150 Z20: 200 Z25: 250 Z30: 300 Z40: 400 Z50: 500 Grounding G: Grounded, 80% rated J: Ungrounded, 80% rated ccessory Suffix Cells (See Table.151 to Table.155) DE2 Discount -59

Selection Information 7-2. QO and QOU Miniature Circuit Breakers Multi 9 TM Miniature Circuit Breakers 7-16

Selection Information 7-2. QO and QOU Miniature Circuit Breakers Multi 9 TM Miniature Circuit Breakers 7-16 Table of Contents Section Miniature and Molded Case Circuit Breakers H-Frame J-Frame Selection Information -2 QO and QOU Miniature Circuit Breakers -10 QO Miniature Circuit Breakers -10 QO Circuit Breaker

More information

Selection Information. Multi 9 Miniature Circuit Breakers. Motor Circuit Protectors. Automatic Switches. 500 Vdc Circuit Breakers DE3-35

Selection Information. Multi 9 Miniature Circuit Breakers. Motor Circuit Protectors. Automatic Switches. 500 Vdc Circuit Breakers DE3-35 Circuit Breakers Selection Guide Description Page Selection Information -2 QO and QOU Miniature Circuit Breakers -10 B-Frame H-Frame QO Miniature Circuit Breakers QO Circuit Breaker Accessories QO and

More information

Selection Information. Multi 9 Miniature Circuit Breakers. Motor Circuit Protectors. Automatic Switches. 500 Vdc Circuit Breakers DE3-35

Selection Information. Multi 9 Miniature Circuit Breakers. Motor Circuit Protectors. Automatic Switches. 500 Vdc Circuit Breakers DE3-35 Circuit Breakers Selection Guide Description Page Selection Information -2 QO and QOU Miniature Circuit Breakers -10 H-Frame J-Frame QO Miniature Circuit Breakers QO Circuit Breaker Accessories QO and

More information

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories QO and Miniature ircuit reakers QO ircuit reaker ccessories lass 1130 / Refer to atalog 0730T9801 IRUIT RKRS ccessories for Use with QO and QO Miniature ircuit reakers Handle ttachments escription at.

More information

Qwik-Gard Circuit Breakers With Ground Fault Circuit Interrupter 2P Common Trip. Discount Schedule DE2A

Qwik-Gard Circuit Breakers With Ground Fault Circuit Interrupter 2P Common Trip. Discount Schedule DE2A OR URRNT INORMTION I I Two-wire SWN New! 2P I Three-wire SWN QO With Shunt Trip K Key Operated QO and Miniature ircuit reakers QO rc-ault ircuit reaker QO arc-fault circuit breakers provide branch feeder

More information

1.5 INCH W X 2.91 INCH D X 3 INCH H

1.5 INCH W X 2.91 INCH D X 3 INCH H 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 ax: 936-560-4685 Q0230 QO230 2P-120/240V-30 Square ompany atalog Number Manufacturer escription Weight per unit Product ategory Q0230 Square

More information

EDB-EPD, EGB-EPD and EJB-EPD (Equipment Protection Device) Circuit Breakers for Ground Fault Protection in NF Panelboards

EDB-EPD, EGB-EPD and EJB-EPD (Equipment Protection Device) Circuit Breakers for Ground Fault Protection in NF Panelboards -P, -P and J-P (quipment Protection evice) ircuit reakers for round ault Protection in N Panelboards Square -P, -P and J-P (quipment Protection evice) ircuit reakers are 1-pole thermal-magnetic circuit

More information

Selection Information Molded Case Circuit Breakers

Selection Information Molded Case Circuit Breakers Selection Information Molded ase ircuit reakers lass 500, 600, 800 100 rame 100 -rame IRUIT RKRS 3 ircuit reaker Type (240 V) H Hb H I Y Number of 1, 2, 3 1 2, 3 1 1 2, 3 2, 3 1 urrent Range 15 100 15

More information

Quality and Innovation for Global Solutions

Quality and Innovation for Global Solutions Commercial and Industrial Circuit Breakers for OEM Applications Quality and Innovation for Global Solutions Make the most of your energy SM One World Source The Opportunity: The world is opening up to

More information

For the most up-to-date information

For the most up-to-date information www.square.com or the most up-to-date information Thermal-magnetic Molded ase ircuit reakers, 2 mpere rame lass 5,, 734, 8 IL3 JL 3-pole circuit breaker -frame, Thermal-magnetic ( Vac) mpere Magnetic Trip

More information

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers QO and Miniature ircuit reakers Miniature ircuit reakers lass 720 / Refer to atalog 0730T9801 Low mpere Miniature ircuit reakers unit mount miniature circuit breakers (cable-in/cable-out) are ideal for

More information

Thermal-Magnetic For Mining Applications Class 600

Thermal-Magnetic For Mining Applications Class 600 Square D www.squared.com FOR CURRENT INFORMATION Molded Case Circuit Breakers for Mining s These circuit breakers with the properly selected trip range provide protection for trailing cables in compliance

More information

Selection Information Molded Case Circuit Breakers

Selection Information Molded Case Circuit Breakers Selection Information Molded ase ircuit reakers lass 500, 600, 800 PowerPact 150 H-rame PowerPact 250 J-rame Trip Version Trip Version ircuit reaker Type H H HJ HL HR J J JJ JL JR Number of 2, 3 2, 3 2,

More information

Laser Service Factory-assembled Panelboards

Laser Service Factory-assembled Panelboards Factory-assembled Panelboards Price List 1600PL0701 2009 Class 1600 CONTENTS Description............................................. Page Product Overview........................................ Page

More information

8 PANELBOARDS. Series Ratings For NQOD, NF and I-LINE Panelboards Class 1630, 1670,

8 PANELBOARDS. Series Ratings For NQOD, NF and I-LINE Panelboards Class 1630, 1670, Series s For NQOD, NF and I-LINE Panelboards Class 16, 1670, 110 This page contains UL Tested and Certified series combination ratings for panelboards. These ratings apply to either an integral main located

More information

The UL listed heart of the LynTec Lighting Control and Sound Sequencing Panels

The UL listed heart of the LynTec Lighting Control and Sound Sequencing Panels The UL listed heart of the Lighting Control and Sound Sequencing Panels Handle functions as a normal circuit breaker. When switched off or tripped due to overload, the remote control will not turn on power.

More information

Retail Products Catalog

Retail Products Catalog Retail Products Catalog www.schneider-electric.us Table of Contents Overview bout Us...4 Product Definitions Types of Circuit Breakers, Residential Load Centers & other Electrical Devices...6 QO Product

More information

Enhancing Short Circuit Selective Coordination with Low Voltage Circuit Breakers

Enhancing Short Circuit Selective Coordination with Low Voltage Circuit Breakers Data Bulletin 0100DB0403R5/05 05/2005 Cedar Rapids, Iowa, USA Enhancing Short Coordination with Low Voltage s Retain for future use. INTRODUCTION DEFINITIONS ASSUMPTIONS CIRCUIT BREAKER BASICS The purpose

More information

I-Line Circuit Breaker Panelboards Catalog 2110CT9701R02/ Class 2110

I-Line Circuit Breaker Panelboards Catalog 2110CT9701R02/ Class 2110 I-Line ircuit Breaker Panelboards atalog 2110T9701R02/16 2016 lass 2110 ONTENTS Description............................................ Page Product Description.................................... Page

More information

Class 0734, 0500 / Refer to Catalogs: 0734CT0201, 0500CT9702. PowerPact G-Frame 3P 100 A Thermal-Magnetic Circuit Breaker (600Y/347 Vac)

Class 0734, 0500 / Refer to Catalogs: 0734CT0201, 0500CT9702. PowerPact G-Frame 3P 100 A Thermal-Magnetic Circuit Breaker (600Y/347 Vac) MINITUR N MOL S IRUIT RKRS PowerPact ircuit reaker JL 3P ircuit reaker QL 2P 0 250 QL 3P 0 250 Tale.46: mpere - and Q-rame ircuit reakers lass 034, 0500 / Refer to atalogs: 034T0201, 0500T902 PowerPact

More information

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Data Bulletin 0611DB0402 R04/16 05/2016 Replaces 0611DB0401 R11/11 PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Retain for future use. Introduction Certifications The electrical

More information

Square D Breakers QOB330 HOM230CP. QUARE D CIRCUIT BREAKERS SQUARE D Q2L3225 (Brand new) 2L3225 Specifications: Model / Cat. No.

Square D Breakers QOB330 HOM230CP. QUARE D CIRCUIT BREAKERS SQUARE D Q2L3225 (Brand new) 2L3225 Specifications: Model / Cat. No. Square D Breakers American International Marketing P.O. Box 9133 Portland OR 97291-033 Closeout #1279-Square-D-Breakers Square D HOM230CP 30A DP Circuit Breaker (NEW) Square D #HOM230CP 30A DP Circuit

More information

LynTec MRTS-12 and MRTS-24 Modular Rain Tight Sequencers

LynTec MRTS-12 and MRTS-24 Modular Rain Tight Sequencers STRT Press ON switch STRT Press ON switch This sequencer serves: TIMING DIGRM DELY TIME STEP RTE are 1 second if no jumpers are installed. Each Sequencer Step controls two breakers, one upper set of terminals

More information

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004 PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3

More information

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS THRML-MNTI/MNTI ONLY MOL S IRUIT RKRS INTROUTION SPTMR, 1991 LSS IV xchange of permanent trip circuit breakers (K, L, M or N) furnished in lieu of circuit breakers specified with interchangeable trip.

More information

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS THRML-MNTI/MNTI ONLY MOL S IRUIT RKRS INTROUTION SPTMR, 1991 LSS IV xchange of permanent trip circuit breakers (K, L, M or N) furnished in lieu of circuit breakers specified with interchangeable trip.

More information

and Refrigeration Institute). CNX Special Purpose Contactors

and Refrigeration Institute). CNX Special Purpose Contactors Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors

More information

QO and HOMELINE Circuit Breaker Load Centers and Enclosures

QO and HOMELINE Circuit Breaker Load Centers and Enclosures QO and HOMELIE Circuit Breaker Load Centers and Enclosures Class 1130, 1131, and 1170 COTET chneider Electric Brands Description Page QO Circuit Breaker Load Centers Class 1130............................

More information

NQOD Circuit Breaker Panelboards

NQOD Circuit Breaker Panelboards NQOD Circuit reaker Panelboards Class 1630 CONTENTS Description Page pplication Data..................................................... 3 Typical Wiring Diagrams..............................................

More information

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 734 0734CT0201R1/07 07 CONTENTS Description..............................................Page Description.............................................

More information

PowerPact B. Molded case circuit breakers and switches from A

PowerPact B. Molded case circuit breakers and switches from A PowerPact B Molded case circuit breakers and switches from 15-125 A 2 schneider-electric.us Efficiency that clicks. PowerPact B molded case circuit breakers Schneider Electric introduces a new family member

More information

2015 $22. Digest 177. digestplus-us.schneider-electric.com

2015 $22. Digest 177. digestplus-us.schneider-electric.com 2015 $22 Digest 177 digestplus-us.schneider-electric.com Schneider Electric brands that deliver the solutions you demand. Square D power solutions ready for the future. Square D TM by Schneider Electric

More information

Multistandard offer for OEM applications. Single solution source for business without borders

Multistandard offer for OEM applications. Single solution source for business without borders Multistandard offer for OEM applications Single solution source for business without borders 1 Improving customer satisfaction means producing industrial machines that are compliant to international standards,

More information

NQOD Circuit Breaker Panelboards

NQOD Circuit Breaker Panelboards Catalog 2005 Class 1630 CONTENTS Description..............................................Page PPLICTION DT.......................................... 3 TYPICL WIRING DIGRMS.................................

More information

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw Industrial Generator Set Accessories Line Circuit Breakers 15-2500 kw Standard Features Single Circuit Breaker Kit with Neutral Bus Bar 15-300 kw Model Shown The line circuit breaker interrupts the generator

More information

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers Catalog 0612CT0101 R02/14 2014 Class 0612 CONTENTS Description............................................. Page General Information..........................................

More information

Series Rated / Fully Rated Tables. Lighting and Appliance Panelboards. Panelboard Special Features

Series Rated / Fully Rated Tables. Lighting and Appliance Panelboards. Panelboard Special Features Table of Contents Section Panelboards NQ Panelboards Page -5, x Series Rated / Fully Rated Tables NQ -2, -42 NF -3 I-Line -3 Lighting and Appliance Panelboards NQ/NF Pricing Procedure -5 NQ Merchandised

More information

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta . Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit

More information

PowerPact H-, J-, and L-Frame Circuit Breakers

PowerPact H-, J-, and L-Frame Circuit Breakers PowerPact H-, J-, and L-Frame Circuit Breakers Catalog 0611CT1001 R01/13 2013 Class 0611 CONTENTS Description............................................. Page Catalog Numbering...........................................7

More information

PowerPact Circuit Breakers 3-3. PowerPact Automatic Switches 3-6. Molded Case Circuit Breakers 3-7. Circuit Breaker Accessories 3-23

PowerPact Circuit Breakers 3-3. PowerPact Automatic Switches 3-6. Molded Case Circuit Breakers 3-7. Circuit Breaker Accessories 3-23 Table of Contents Section 3 Molded Case s and Enclosures PowerPact s 3-3 PowerPact H- and J-Frame s 3-2 3-3 PowerPact L-Frame s 3-4 PowerPact D-Frame s 3-5 PowerPact Automatic Switches 3-6 PowerPact D-frame

More information

Jefferson Public Works Shop Building 2011

Jefferson Public Works Shop Building 2011 BENTON ELECTRIC, INC. SINCE 1967 CCB#4213 GET CONNECTED VOICE 541.967.1244 EMAIL@BENTONELECTRIC.COM Jefferson Public Works Shop Building 2011 701 N Second Street City of Jefferson, Oregon Electrical Equipment

More information

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English. -174 Series C Molded Case Circuit s July 7 Molded Case Switches Refer to Eaton for UL listed, series tested Molded Case Switch application data. Table -278. Molded Case Switches Cont. Amp Rating at 40

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS THRML-MNTI/MNTI ONLY MOL S IRUIT RKRS INTROUTION SPTMR, 1991 LSS IV xchange of permanent trip circuit breakers (K, L, M or N) furnished in lieu of circuit breakers specified with interchangeable trip.

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Cutler-Hammer Vol. -2 Product Line Overview Vol. 1, Ref. No. [0468] Product Line Description Cutler-Hammer Molded Case s are designed to provide circuit protection for low voltage distribution systems.

More information

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units -1 1 Amperes July 07 Product Selection Table -191. s, H and C Thermal-Magnetic Circuit s with Interchangeable Trip Units Maximum Continuous Ampere at 40 C 2-Pole 0 0 3-Pole 0 0 4-Pole 0 0 Magnetic trip

More information

Tmax Molded Case Circuit Breakers

Tmax Molded Case Circuit Breakers Tmax Molded Case Circuit s Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

PowerPact H-, J-, and L-Frame Circuit Breakers

PowerPact H-, J-, and L-Frame Circuit Breakers PowerPact H-, J-, and L-Frame Circuit Breakers Catalog 0611CT1001 R05/15 2015 Class 0611 CONTENTS Description............................................. Page Catalog Numbering...........................................7

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers Molded Case Circuit Breakers LMD 800A Frame Sentron Series Type LMXD6 Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs) Blue Label Continuous 2-Pole (3 Pole Width) 3-Pole Current Rating

More information

Class 730, 731, 733 / Refer to Catalog: 0730CT9801

Class 730, 731, 733 / Refer to Catalog: 0730CT9801 LA CENTES Q Miniature Circuit s Q Plug-n Circuit s Class 730, 73, 733 / efer to Catalog: 0730CT980 www.schneider-electric.us Square brand Q miniature circuit breakers are plug-on products for use in Q

More information

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1 Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series B Ex9BE3C0 Ex9BHC6 www.noarkus.com NORK Ex9 Series B NORK Miniature Circuit Breakers offer these advantages: highperformance, small size, exemplary

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

PD-Series Ground Fault Circuit Protection

PD-Series Ground Fault Circuit Protection PD-Series Ground Fault Circuit Protection SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/ magnetic circuit breaker, offering customized

More information

Do you need electrical distribution equipment for your home? Review our selection in the 2009 Retail Catalog. Make the most of your energy SM

Do you need electrical distribution equipment for your home? Review our selection in the 2009 Retail Catalog. Make the most of your energy SM Do you need electrical distribution equipment for your home? Review our selection in the 2009 Retail Catalog. Make the most of your energy M Thinking Outside the quare > Who we are chneider Electric total

More information

Product Line Overview. The Most Logically Designed Contact Assembly

Product Line Overview. The Most Logically Designed Contact Assembly Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

PB-Series. GFCI/ELCI & Panel Seal

PB-Series. GFCI/ELCI & Panel Seal PB-Series GFCI/ELCI & Panel Seal The PB-Series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments.

More information

TeSys Motor Starter Solutions for the North American Market

TeSys Motor Starter Solutions for the North American Market TeSys Motor Starter Solutions for the North American Market Data Bulletin 8536DB0901 Tesys Motor Starter Solutions 8536DB0901 Table of Contents 11/2009 Table of Contents Introduction... 3 Overview of U.S.

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

QMB Fusible Panelboards

QMB Fusible Panelboards Catalog 4620CT9601R04/09 2009 Class 4620 CONTENTS Description............................................. Page Overview.............................................. Page 3 QMB Switches..........................................

More information

Integrated Power Center

Integrated Power Center Class 2735 CONTENTS Schneider Electric Brands Description Page Product Description.................................................. 3 Features and Benefits.................................................

More information

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics Miniature circuit breakers General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for

More information

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB PRODUCT CATALOG SELECTION GUIDE UTS400 CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL UL SERIES & FRAME: Susol 400AF PERFORMANCE Rating 80% 0% ka N NT 65 SUFFIX UL : UL 240Vac H HT 0 L

More information

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame Cutler-Hammer January 200 Vol., Ref. No. [077] s Molded Case s 5-00 Amperes 2- 2-2 Product Line Overview January 200 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case s are designed

More information

22.000A IR. Catalog Number. Price $

22.000A IR. Catalog Number. Price $ Full Size (" per Pole) with INSTA-WIRE -Pole Plug-In (V AC) Type MP-T Type MP-HT Type MP-MT Continuous Current Rating @ C 5 25 35 5 0.000A IR Catalog Number MP5 MP MP25 MP MP35B MP MP5B MP MPB MPB List

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

Type MP-T Type MP-HT Type MP-MT

Type MP-T Type MP-HT Type MP-MT CIRCUIT BREAKERS 2 Circuit Breakers Full Size (1 per Pole) with INSTA-WIRE 1-Pole Plug-In (120V AC) Type MP-T Type MP-HT Type MP-MT Continuous 10,000A IR 22,000A IR 65,000A IR Current Rating Catalog List

More information

Technical Information

Technical Information Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,

More information

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers Catalog 0612CT0101 R02/16 2015 Class 0612 CONTENTS Description............................................. Page General Information..........................................

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Catalog 4141CT0701 2008 Class 4141 MP44125 MP86200 CONTENTS Description..............................................Page Product Description........................................... 2 General and Application

More information

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems NEHB Circuit Breaker Panelboards For 480Y /277V. ac Systems www. ElectricalPartManuals ElectricalPartManuals. com com NEHB Panelboards EHB (bolt-on) Circuit Breakers MONO-FLAT front features completely

More information

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units -22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers SMD 800A Frame Digital Solid State Sentron Sensitrip III Series Selection Type SMD6 Type SHMD6 Current Limiting Type SCMD6 Blue Label Black Label Red Label Catalog Current List SMD69600A 600 SMD69700A

More information

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W July 07 5 Amperes -111 Product Selection This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog numbers for circuit breakers or trip units.

More information

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes. Catalog Number System For illustrative purposes only. Circuit Breaker Selection Guide T H QL 5 GE Identification Interrupting Rating Type Poles Voltage mpere Rating Insert for Specials H = 0kIC QL = Plug-in

More information

Thermal-Magnetic Circuit Breakers. Electronic Trip Circuit Breakers. Breaking Capacities 9-7 Circuit Breaker Dimensions 9-8

Thermal-Magnetic Circuit Breakers. Electronic Trip Circuit Breakers. Breaking Capacities 9-7 Circuit Breaker Dimensions 9-8 Table of Contents Section 9 International Circuit Breakers Thermal-Magnetic Circuit Breakers SF and SL Circuit Breakers, IC Rated 415/240 Vac Max. 9-2 lectronic Trip Circuit Breakers P-frame, 3P, Micrologic

More information

Lighting Contactors. 6.1 Open Control. Product Overview...

Lighting Contactors. 6.1 Open Control. Product Overview... Lighting Contactors C30CN Mechanically and Electrically Held.1 Product Overview........................................ C30CN Mechanically and Electrically Held Product Description....................................

More information

A200 NEMA Contactors and Starters A200

A200 NEMA Contactors and Starters A200 Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G . NG-Frame (00 ) NG-Frame (30 00 s) Product All Eaton NG-Frame circuit breakers are suitable for reverse feed use All NG-Frame circuit breakers are HACR rated Contents Page EG-Frame (5 5 s)..................

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

POWERBUS 225 Busway and Plug-In Units

POWERBUS 225 Busway and Plug-In Units Busway and Plug-In Units Class 5600 CONTENTS Schneider Electric Brands Description Page Product Descriptions.................................................. 3 POWERBUS 225 Busway System.....................................

More information

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic Certi cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 3211 04 INDUSTRIAL CONTROL EQUIPMENT Motor Controllers

More information

Molded Case Circuit Breakers

Molded Case Circuit Breakers Type SND6 Molded Case Circuit Breakers SND 1200A Frame Digital Solid State Sentron Sensitrip III Series Type SHND6 Current Limiting Type SCND6 Blue Label Black Label Red Label Catalog Current Price SND69800A

More information

General + Definite Purpose Contactors

General + Definite Purpose Contactors General + Definite Purpose General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Series C8 Miniature and Starters... 3 ccessories... 2 Contactor Cross

More information

Restricted to Schneider Electric Personnel. Class 2700/2705/2741/2742 QED-2. OEM Interiors

Restricted to Schneider Electric Personnel. Class 2700/2705/2741/2742 QED-2. OEM Interiors QED-2 Low Voltage Switchboards Square D Brand OEM Interiors Schneider Electric MDS Low Voltage Switchboards SW-2 Pricing Guide 2700PL9201R09/13 2013 Class 2700/2705/2741/2742 Restricted to Schneider Electric

More information

4.2. Definite Purpose Contactors and Starters. Contents A, Two-, Three- and Four-Pole C25. Contactors

4.2. Definite Purpose Contactors and Starters. Contents A, Two-, Three- and Four-Pole C25. Contactors .2 Definite Purpose and Starters 5 360, Two-, Three- and Four-Pole 25 5 360, Two-, Three- and Four-Pole 25 Product Description Eaton offers the most comprehensive line of definite purpose contactors in

More information

1489-M Circuit Breakers

1489-M Circuit Breakers Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

PANELBOARDS C1/C2 SECTION 6

PANELBOARDS C1/C2 SECTION 6 SECTION 6 C1/C2 PANELBOARDS Page General Specifications 6-2 Box Sizing 6-2 Gauge Steel Boxes 6-2 Fronts 6-2 Main Breaker Connectors 6-2 Main Lug Connectors 6-2 Selection 6-3 6-5 Main Lugs Only C1 and C2

More information

Transfer switch OTEC open or delayed transition

Transfer switch OTEC open or delayed transition Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.

More information

UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45]

UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45] Multi 9 System Catalog UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers Figure 46: UL 489/CSA C22.2 No.5 Listed C60 240 Vac Circuit Breaker with Box Lug Terminals Figure 47: UL 489/CSA C22.2 No.5 Listed

More information