1 ##CFG BWOP Manuals## Quasar elite HD-LED Mobile Models Assembly Guide IG-Qe60-MOBILE Issue A2 26 th November 2014
2 Galaxy Ultra Mobile & HD-LED Models Brandon Medical Company Ltd All rights are reserved. No part of the content may be reproduced, adapted, stored in a retrieval system or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise without the prior permission of the Copyright owner. Whilst every effort is made to ensure the accuracy and completeness of this guide, we do not warrant that the content is error free. The brand names or product names mentioned or referred to throughout this guide are fully recognised as the trademark or registered trademark of their respective owners. Page 2 of 25 IG-Qe60-MOBILE
3 Contents Contents 1 Before starting the assembly Symbols used Models covered Classifications Environmental conditions Related guides Electrical Installation Supply requirements Emergency Power Supply (EL Versions Only) Operations Mechanical Assembly Component List Assembly operations Fitting the Sterilisable Handle system Mechanical Adjustment Adjusting the Spring Arm Transporting the Mobile Lamp Settings Entering the Setting Mode Changing Power-On behaviour Changing the default intensity at power-up Changing the default colour temperature at power-up Setting the service hour counter Pairing the Remote Control (if supplied) Commissioning the unit Checklist Guarantee Terms of the Guarantee Conditions of the Guarantee Disposal instructions Declaration of Conformity...24 IG-Qe60-MOBILE Page 3 of 25
4 Quasar elite Mobile Models 1 Before starting the assembly For your full satisfaction with this equipment, it is recommended that you read this section carefully before starting the assembly. 1.1 Symbols used The symbols used in this guide and on the product are explained in the following table. Symbol! Description WARNING/DANGER Pay special attention. Note this point. Refer to another section/guide. 1.2 Models covered Model Qe60M Qe60MEL Approx. weight 110 kg 140 kg 1.3 Classifications The classifications are explained in the following table. Classification Description Electrical classification Class 1 Classification according to EU Medical Device Directive 93/42/EEC Lamp head degree of protection from ingress of dust and water Degree of protection against the presence of flammable anaesthetic mixtures Class 1 IP54 Not for use in a flammable atmosphere Page 4 of 25 IG-Qe60-MOBILE
5 Before starting the assembly 1.4 Environmental conditions The environmental conditions relate to transportation/storage and operating Transportation and storage The environmental conditions relating to transportation and storage are explained in the following table. Condition Temperature Relative humidity Pressure Range -40 o C to 70 o C 10% to 95% non-condensing 500hPa to 1060hPa Operating The environmental conditions relating to operating are explained in the following table. Condition Temperature Relative humidity Range 15 o C to 30 o C ambient temperature 10% to 80% non-condensing 1.5 Related guides The other guides that relate to the Quasar elite LED lamps are: Quasar elite HD-LED Quick Start Guide Quasar elite HD-LED Instructions for Use Quasar elite HD-LED Routine Maintenance Guide. IG-Qe60-MOBILE Page 5 of 25
6 Commissioning the unit 2 Electrical Installation 2.1 Supply requirements Installation should only be carried out by a suitably qualified general electrician. This model comes pre-wired with a mains plug. 2.2 Emergency Power Supply (EL Versions Only) The EL model is fitted with an emergency battery backup system so that in the event of mains power failure the lamp will still operate. On receipt of the lamp the batteries will require charging for 12 hours to ensure they are fully charged. The lamp should always be connected to the mains supply to maintain the battery charge whether in use or not. Allowing the battery to become discharged for prolonged periods may result in poor battery performance. Note: Temperature and Humidity can affect the battery life and extremes of temperature will certainly reduce the life of the battery. See operating conditions at section Operations Indicator Description Under normal mains supply the green indicator will be illuminated. If there is a fault with the charger or the batteries are not fully charged, then the red indicator will illuminate. Ensure the lamp is connected to the mains supply, i.e. the green indicator is on, and leave to charge for a minimum of 12 hours and up to a maximum of 24 hours. If the indicator is still illuminated there is a fault with the charging system and you must consult your local service agent or contact Brandon Medical. When the mains supply is disconnected then the red indicator will illuminate, showing the batteries are in use. The lamp will continue to operate until the batteries become discharged at which point the batteries will become disconnected and the lamp will not illuminate. The mains supply should be re-established before the lamp will reilluminate. The batteries will need to be fully recharged. Table 1 IG-Qe60-MOBILE Page 6 of 25
7 Maintenance instructions 3 Mechanical Assembly 3.1 Component List Unpack the boxes and check that all the parts listed in the following table are present. Description Quantity Note Top column 1 Packed inside the base pallet Spring arm 1 Separate box Main handle 1 Packed inside the base pallet Hardware pack 1 Packed with sterile handle Sterile handle 1 Packed inside the lamp head box Mobile base 1 Packed inside the base pallet Lamp head 1 Separate box Table 2 Examine all the parts carefully for any damage in transit. Report any damaged or missing items to the supplier within 5 working days. IG-Qe60-MOBILE Page 7 of 25
8 Astralite LED Mobile Models 3.2 Assembly operations Before connecting, check the electrical requirements as detailed on the serial number label located on the top column correspond with your supply Assembling the Base Referring to the images below; feed the electrical cable through the grab handle and place the handle over the main vertical column on the mobile base. Fixing holes Fig 1 Fig 2 Fig 3 Note the orientation of the grab handle with the fixing holes facing downwards Referring to the images below; insert the top column into the main column through the grab handle, feeding the electrical cables through from the mobile base. Top Column Dowel Pin Slot Fig 4 Fig 5 Fig 6 Note the orientation of the column and align the dowel pin with the slot inside the grab handle. Secure the main handle using 4 Qty cap head bolts supplied. Page 8 of 25 IG-Qe60-MOBILE
9 Maintenance instructions Fitting the spring arm Press the electrical plug, from the top column, into the electrical plug on the spring arm assembly. Align the spring arm assembly with the mobile base as shown below. Lower the spring arm assembly into the top column. When fully inserted; align the 3 vacant holes in the spring arm assembly with the corresponding holes in the column, then secure with 3 counter sunk screws provided. Spring Arm Assembly CSK Screw Brake screw adjustment hole Fig 7 Note the rear column hole should be left clear. This is for brake screw adjustment. A small plastic plug is provided to cover the brake screw. IG-Qe60-MOBILE Page 9 of 25
10 Astralite LED Mobile Models Mounting the Lamp head! The spring arm will be supplied locked in the horizontal position. It should always be locked in the horizontal position when fixing or removing the lamp head. Remove both covers by unscrewing the fixing screws then putting a flat screwdriver in the join; prise open the 2 halves and separate. Unscrew the locking screw; then slide back the securing ring to expose the locking segment. Using a pair of pliers; lift the segment clear. Locking Screw Fixing Screw Cover Segment Securing Ring Fig 8 Securely position the mobile with brakes applied. Referring to the images below, with the spring arm held securely; align the plug in the Lamphead spigot with the socket in the spring arm. Insert the lamp head spigot fully into the end of the spring arm. Insert the segment to secure the Lamphead, then slide the securing ring forward and replace the locking screw. Replace the both covers. Fig 9 Fig 10 Fig 11 Page 10 of 25 IG-Qe60-MOBILE
11 Maintenance instructions 3.3 Fitting the Sterilisable Handle system Screw the handle carrier on to the threaded handle mount until tight. Now screw the grub screw in until it is tight. The handle carrier will now be secure. To fit a sterilisable handle cover you only need to push the handle cover over the Carrier until an audible click is heard and the handle has locked in position. As shown below. To release the sterilisable handle cover, simply push the blue release button and the cover can be removed. Grub Screw Release Button Fig 12 Fig 13 Sterile Handle Cover (HM33562)! The sterilisable handle as supplied is not sterile. You must sterilise it by autoclave typically steam sterilisation at 134 C for three minutes. IG-Qe60-MOBILE Page 11 of 25
12 Astralite LED Mobile Models 4 Mechanical Adjustment Before first use; the lamp must be balanced. This is achieved by using the Spring arm tensioning mechanism, details of which are shown in this section. Adjustments may be made to the brake screws used to dampen the freedom of travel, also shown in this section.! Do not attempt to remove the lamp head as this could cause serious injury. 4.1 Adjusting the Spring Arm Bearing Housing Brake Screw (mobile models) Remove the plastic cover at the rear of the bearing housing to reveal the brake screw. Turn the brake screw clockwise to tighten or anti-clockwise to loosen. Plastic Cover Fig Vertical height adjustment To set the vertical height; locate the adjusting screw which can be found at the rear of the spring arm. Insert a 5mm Hex key into the hole. Rotate clockwise to reduce and anti-clockwise to increase the vertical height of the spring arm. Fig 15 Page 12 of 25 IG-Qe60-MOBILE
13 Maintenance instructions Balance adjustment Remove 2 retaining screws then using a thin screwdriver gently push and disengage the two outer cover halves then remove. A 4mm dia x 110mm long rod, supplied with the spring arm, should be inserted into the adjustment hole. Turn the adjustment nut inside the arm by moving the rod up and down as required. Move up to increase the tension and down to decrease the tension. When adjusted, replace covers and retaining screws. Retaining Screw Rotational Adjustment Fig 16 Remove 2 retaining screws then using a thin screwdriver gently push and disengage the two outer cover halves then remove. To increase the braking force simply insert a flat blade screwdriver into the brake screw and turn the screws alternately in the + direction with the same number of revolutions. Brake Screw Fig 17 IG-Qe60-MOBILE Page 13 of 25
14 Astralite LED Mobile Models 5 Transporting the Mobile Lamp Before moving the mobile unit ensure the lamp is placed in the Transport position, where the spring arm is positioned centrally along its axis and the Lamp head is in its lowest position, see image below. Ensure that all brakes are released and that the unit is un-plugged from the mains socket and stowed safely. Push the unit slowly using the blue Grab handle in the direction indicated below. Spring Arm Handle Direction of Travel Direction of Travel Spring Arm Lamp head Fig 18 Fig 19 Transport position top view Transport position side view! The mobile unit can only be moved on a smooth even surface. Small rises or steps may cause the unit to stop abruptly allowing it to over balance. Page 14 of 25 IG-Qe60-MOBILE
15 Maintenance instructions 6 Settings 6.1 Entering the Setting Mode To enter the default setting mode first press and hold the centre button then simultaneously press the lower Intensity button and the lower Red Balance button marked X below. The key pad display will then illuminate the lower red balance, RB- LED 1, both centre LED s and the lower Intensity LED INT-LED 1. Green Centre LED Red Standby / Service LED INT-LED 6 RB-LED 5 X Focus Button RB-LED 1 X X INT-LED 1 Fig 20 Mode Red Balance (RB)-Led position Intensity-Led position On/Off-Behaviour RB-led 1 On Int-Led 3 Intensity after Power-On RB-led 2 On Refer to Table 2 RB after Power-On RB-led 3 On Refer to Table 4 Table Selecting the Mode & Setting To select different modes use up and down Red Balance buttons to move the RB- LED s to the appropriate position. See table 3 for available modes. To change the value within a particular mode select the + and Intensity buttons to select the setting required. Then press either focus buttons to confirm. Note: the present setting will be indicated by a steady illuminated LED whilst all other settings available will be flashing LED s. IG-Qe60-MOBILE Page 15 of 25
16 Astralite LED Mobile Models 6.2 Changing Power-On behaviour This sets the lamp to illuminate or go to standby when the mains power is first applied to the lamp head. Enter the default setting mode. The mode appropriate mode is entered automatically because power on behaviour is the first mode. If INT 1 LED is flashing then power on standby is set. To change to power 0n illuminated, press either focus button. The INT 1 LED will go solid and the change is confirmed. If INT 1 LED is solid then power on Illuminated is set. To change to power on standby, press the (+) INT button. INT 2 LED will flash. Press either focus button to confirm and the LED will go solid. To leave the default setting mode press the centre button. Note: The factory default setting is Power on standby. 6.3 Changing the default intensity at power-up This sets the lamp intensity when the lamp is powered. Enter the default setting mode. Select the mode by pressing the up RB button until RB-LED 2 in on. Using the INT + and buttons move up or down to select a value. See table 4 below. Then press either focus buttons to confirm. To leave the default setting mode press the centre button Note: The factory default level for light intensity is 3, i.e. three of the six LED s are illuminated. Intensity-Led Intensity after Power-On 1 8 % 2 13 % 3 20 % 4 40 % 5 65 % % Table 4 Page 16 of 25 IG-Qe60-MOBILE
17 Maintenance instructions 6.4 Changing the default colour temperature at power-up This sets the colour temperature of the lamp when first powered up using the on/off button. Enter the default setting mode. Select the mode by pressing the up RB button until RB-LED 3 in on. Using the INT + and buttons move up or down to select a value. See table 5. Then press either focus buttons to confirm. Note: the factory default level for Red Balance (colour temperature) is 3, i.e. three of the five LED s will be illuminated. To leave the default setting mode press the centre button RB-LED Table Setting the service hour counter Not available on this model. Red Balance / Colour Temperature 1 Full Red 2 3 Factory Default 4 5 No Red IG-Qe60-MOBILE Page 17 of 25
18 Astralite LED Mobile Models 6.6 Pairing the Remote Control (if supplied) Pairing Read this whole section prior to commencing the pairing operation. If the Lamp head has been paired previously; then it must be un-paired before starting the pairing operation. See section below. A time window of approximately 8 seconds exists between steps 5 & 6. This connects the lamp head with a remote control handset which is available separately. 1. Before starting the lamp head must be off with the standby light illuminated. 2. Enter the default setting mode on the lamp head keypad. (See section 5.1) 3. Select the mode by pressing the up RB button until RB-LED 1 & 2 are both illuminated. 4. INT LED 1 should be illuminated and solid. Note: If INT LED 1 is flashing then the lamp head is already paired and must be unpaired before continuing. See notes below. 5. Using the INT + button move the value up 1 increment until Int-LED 2 is flashing. 6. Now press the pairing button on the remote until the single green led comes on. within 3 seconds, push either focus buttons on the lamp head keypad. There will be a delay of a further 3 seconds and then 2 Red LED's will light on the remote. 7. If successful the Quasar elite keypad will return to standby, (single red LED illuminated). 8. Press the Lamp head power button 2 times to complete the pairing. The lamp will now be illuminated and the handset will be paired with the Lamp head. Pairing Button Fig 28 Notes: 1. The first lamp to be paired will be allocated to channel one on the remote. 2. If you are having problems pairing the lamp and the remote control then un-pair and start again. See section 5.7. To leave the default setting mode press the centre button. Page 18 of 25 IG-Qe60-MOBILE
19 Maintenance instructions 6.1 Un-pairing the remote control Un-pair the system To un-pair both the remote keypad and the lamp head simultaneously: Ensure that lamp head or multiple lamp heads and the remote keypad are switched off but with the power on standby. Press and hold the remote keypad pairing button until the display goes from a single green to a pair of red LED s, approx 10 seconds. Press the remote keypad power button to complete the un-pairing Un-pair the lamp head only To un-pair the lamp head or multiple lamp heads without access to the remote keypad: Using the lamp head keypad enter the default setting mode (see section 5.1). Select the mode by pressing the up RB button 6 times until RB-LED 1 (Red) & RB-LED 3 (green) are both illuminated. INT LED 1 should be illuminated and flashing. Note: If INT LED 1 is solid then the lamp head is already unpaired. Using the INT + button move the value up 1 increment until Int-LED 2 is solid. Press either focus buttons to confirm. Press the lamp head power button 2 times to complete the un-pairing. To leave the default setting mode press the centre button. Notes: 1. If multiple lamp heads are fitted then each lamp head will need to be un-paired separately using this method. IG-Qe60-MOBILE Page 19 of 25
20 Astralite LED Mobile Models 7 Commissioning the unit Check all movements of the lamp to ensure it rotates freely and that the lamp head stays in position without drifting. Before use, fit the sterilisable handle system and sterilisable handle covers to the lamp. The sterilisable handle covers as supplied are not sterile. For a full list of items to be checked, please consult and complete the Checklist. Refer to Section 8. Hand the Instructions for Use over to the Clinical Manager and hand the Routine Maintenance Guide over to the Engineering Maintenance Manager. When commissioning an EL model use the plug provided to connect the lamp to the mains supply and leave connected for a minimum of 12 hours before use. Page 20 of 25 IG-Qe60-MOBILE
21 Warranty 8 Checklist Site Data Hospital Room Location. Model installed Serial No. Light Intensity Lux at 1 metre Inspection Initial Comments Check operation of all switches and indicators Check correct operation of focus control Check correct operation of focus mechanism Check all articulations move freely Check all spring arms are balanced correctly Check external surfaces are free from scratches Clean front screen Secure Sterilisable Handle to lamp head Fit or pass sterilisable handle covers to customer Pass all maintenance guides to customer Additional notes: Customer Acceptance Signature Print name Position Date IG-MINOR SPACER Page 21 of 25
22 Astralite LED Mobile Models 9 Guarantee 9.1 Terms of the Guarantee Subject to the conditions listed below Brandon Medical Company Ltd guarantee to provide for the repair of, or at its option replacement of Brandon Medical equipment, or any component thereof (other than consumables), found to be faulty or below standard, as a result of inferior workmanship or materials. This Guarantee will be passed to the purchaser through the Approved Brandon Medical Distributor where equipment is purchased outside of the United Kingdom. 9.2 Conditions of the Guarantee This Guarantee shall only apply to defects or faults that are notified to Brandon Medical Company Ltd. or its Approved Distributor within 12 months of the delivery date. This Guarantee covers equipment intended for use in hospitals and healthcare establishments only. It is a condition of the Guarantee that the equipment is maintained as recommended in the instruction manuals provided. This Guarantee does not cover and is invalidated by faults or defects caused by accident, misuse, fair wear and tear, neglect, tampering with the equipment, or any attempt at adjustment or repair other than by Brandon Medical approved Service Technicians. In the unlikely event of the equipment requiring repair, please contact the Dealer or Supplier from whom it was purchased. Where this is not possible or where the equipment was purchased direct from Brandon Medical Company Ltd., please contact us directly: Tel: +44 (0) Fax:+44(0) enquiries@brandon-medical.com The cost of any carriage to and from the Dealer, Supplier, Brandon Medical Company Ltd or approved Service Agent shall be borne by the Purchaser. This Guarantee cannot be varied except by written notification by Brandon Medical Company Ltd authorised by a Company Director. Under no circumstances whatsoever shall Brandon Medical Company Ltd. be liable in respect of consequential loss. The Guarantee is subject to the equipment in question having been paid for in full. This Guarantee is offered as an additional benefit to the Purchaser s statutory rights and does not affect these rights in any way. Page 22 of 25 IG-Qe60-MOBILE
23 Disposal instructions 10 Disposal instructions Do not dispose of the light with normal refuse. Depending on local regulations, dispose of the light at a recycling centre or return it to a dealer with a disposal service. Equipment must be de-contaminated before disposal or return to dealer. IG-Qe60-MOBILE Page 23 of 25
24 11 Declaration of Conformity Brandon Medical Co Ltd hereby declares that all Quasar elite Mobile products are in compliance with the EC Directive 93/42/EEC. The Class 1 medical devices specified above conforms to the essential requirements listed in the Annex 1 of the EC Directive 93/42/EEC of 14 June Despite any compliance with EMC standards, the device may emit radiation that interferes with adjacent equipment. If this becomes apparent then increase the distance between the two pieces of equipment.
25 IG-Qe60-MOBILE Page 25 of 25
##CFG BWOP Manuals## Astramax Mobile Models Assembly Guide
##CFG BWOP Manuals## Astramax Mobile Models Assembly Guide IG-AMAX-MOBILE Issue B2 18 th March 2015 Brandon Medical Company Ltd All rights are reserved. No part of the content may be reproduced, adapted,
More information##CFG BWOP Manuals## 24v Emergency Power Unit Installation & Instructions for Use
##CFG BWOP Manuals## 24v Emergency Power Unit Installation & Instructions for Use IFU-BEPU0300L24 Issue A1, 26 th September 2015 Contents 1 General...3 1.1 Symbols used... 3 1.2 All rights reserved...
More informationfreedom through lightweight solutions
freedom through lightweight solutions Mangar Inc. 3020 Legacy Dr. Suit 100-301 Plano, TX 75023 tel: 1-800-901-5269 www.mangarusa.com Mangar International Presteigne Powys LD8 2UF Wales, UK tel: +44(0)1544
More informationNCSA 20plus Service Manual
Adam Equipment NCSA 20plus Service Manual (P.N. 7.00.6.6.0247- Revision A - August 2012) Adam Equipment Company 2012 1.0 CONTENTS 1.0 CONTENTS...1 1.1 KEY AND PANEL DESCRIPTION...2 2.0 OPERATION...3 2.1
More informationfreedom through lightweight solutions
freedom through lightweight solutions Mangar International Presteigne Powys Wales, LD8 2UF tel: +44 (0)1544 267674 fax: +44 (0)1544 260287 e-mail (): customerservice@mangar.co.uk e-mail (Export): export@mangar.co.uk
More informationV4 Cordless Lamp System User Guide
V4 Cordless Lamp System User Guide Contents Welcome Important Notes Components + Connection Diagram Charging Status Indicator Charging the Battery Lamp Control + Operating Modes Turning Function Operating
More informationELECTRICAL. Laser Distance Measure User Guide
ELECTRICAL Laser Distance Measure User Guide Contents 1. 2-3. Welcome Section General Information & Safety Instructions 4. 5-6. Contents & Features General Layout 7. 9-10. Setting Up Installing The Battery
More informationCONTACTS EGR VALVE TESTER 66248
EGR VALVE TESTER 66248 These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any subsequent
More informationMangar Archimedes Instruction & Safety Manual
Mangar Archimedes Instruction & Safety Manual Please read this manual before operation, for maintenance instructions and safe usage The enabling power of applied knowledge Mangar Archimedes, Instruction
More informationGENERAL INFORMATION. INSTRUCTIONS FOR 500A Lithium Jump Starter
INSTRUCTIONS FOR 500A Lithium Jump Starter Stock No.15067 Part No.LJS136 IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS PRODUCT. GENERAL INFORMATION These
More informationPRISM MEDICAL UK SA160C STAND AID
PRISM MEDICAL UK SA160C STAND AID USER GUIDE Unit 1, Tir Llwyd Industrial Estate, St Asaph Avenue, Kinmel Bay, Nr Rhyl, Conwy, LL18 5JZ info@prismmedical.co.uk Tel +44 (0)1924 840100 www.prismmedical.co.uk
More informationArchimedes. user instructions. Simple solutions for everyday independence
rchimedes user instructions Simple solutions for everyday independence rchimedes The rchimedes by Mangar International, is a light weight battery powered actuator driven bathlift, designed to be easily
More information2 TONNE TROLLEY JACK
2 TONNE TROLLEY JACK 61829 IMPORTANT: Please read these instructions carefully to ensure the safe and effective use of this product and save these instructions for future reference. This manual has been
More informationDIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE
DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE W.CHRISTIE (INDUSTRIAL) LTD CHRISTIE HOUSE, MEADOWBANK ROAD, ROTHERHAM, SOUTH YORKSHIRE, S61 2NF, UK T: +44(0)1709 550088 F: +44(0)1709 550030 E:
More informationRoller Door Operator
INSTALLATION INSTRUCTIONS AND OWNERS MANUAL Roller Door Operator IMPORTANT PLEASE READ THESE INSTRUCTIONS CAREFULLY PRIOR TO COMMENCING THE INSTALLATION OF THE OPERATOR UNIT CAUTION This Automatic Opener
More information3 Ton Trolley Jack. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.
Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate
More informationKeContact P20. User manual
KeContact P20 User manual Comments to this manual In this manual you will find warnings against possible dangerous situations. The used symbols apply to the following meanings:!! WARNING! Indicates a potentially
More informationAPPLICATION GUIDE FOR: CAMSHAFT DRIVE CHAIN WEAR INDICATOR
BRITISH MADE APPLICATION GUIDE FOR: CAMSHAFT DRIVE CHAIN WEAR INDICATOR 16239 This document is part of the product, keep it for the life of the product passing it on to any subsequent holder of the product.
More information1000mA - 650mA Phase Dimmable LED Driver
Installation Guide DGLC1000C25PD 1000mA - 650mA Phase Dimmable LED Driver PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU
More informationCONTACTS RELAY TESTER 66249
RELAY TESTER 66249 These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any subsequent holder
More informationPROFESSIONAL CORDLESS IMPACT SCREWDRIVER
PROFESSIONAL CORDLESS IMPACT SCREWDRIVER Model CIS00 Part No 4500625 OPERATING & MAINTENANCE INSTRUCTIONS GC0309 INTRODUCTION Thank you for purchasing this CLARKE Impact Screwdriver. Before attempting
More information3.25 Ton Heavy Duty Floor Jack
Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate
More informationInstruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:
Check out what else you can get from Martindale: 17th Edition Testers Accessories Calibration Equipment Continuity Testers Electricians Kits Environmental Products Full Calibration & Repair Service Fuse
More information6 Bay Battery Charger Operation Manual
6 Bay Battery Charger Operation Manual Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216 USA Customer Service: 904 737 7611 Toll Free 877 677 2832 EC REP RMS UK, Ltd. 28 Trinity Road
More information650mA Phase Dimmable LED Driver
Installation Guide DGLC650C18PD PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU Diginet Control Systems Pty Ltd ABN 89 095
More informationEazipole Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains
Eazipole Cordless Installation & Set Up Instructions Electric Blinds & Curtains Pole Installation - Deciding The Best Position Points to consider when planning the installation of your pole It may be easiest
More informationDC Master 24/ A
USERS MANUAL DC Master 24/12 50-60A DC-DC converter MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com ENGLISH Copyright 2015
More information3 TONNE TROLLEY JACK
3 TONNE TROLLEY JACK 16407 These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any subsequent
More informationDALI 650mA LED Driver
Installation Guide DGLC650C18DD PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU Diginet Control Systems Pty Ltd ABN 89 095
More informationEazidraw Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains
Eazidraw Cordless Installation & Set Up Instructions Electric Blinds & Curtains Features Quiet, DC battery motor with low power consumption. Rechargeable battery with up to 500 uses between charges Fully
More informationTechnical Documentation
Technical Documentation Product manual Holding brake controller Document: 0198441113316 Edition: V1.00, 03.2006 Important information The drive systems described here are products for general use that
More informationPro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.
Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate
More informationHD18F2M1.
HD18F2M1 www.blackanddecker.com 3 2 1 5 A 4 5 B 4 7 10 9 C 4 6 D 4 8 1 11 12 E 2 F 3 2 G H 13 I 14 13 14 K 3 J 3 L M 16 15 4 Intended use Your Black & Decker hand held vacuum cleaner has been designed
More informationBefore installing this unit, read the operating instructions carefully. Strictly adhere to these operating instructions.
Instruction Manual ENGLISH Before installing this unit, read the operating instructions carefully. Strictly adhere to these operating instructions. BIBO QUICK START GUIDE Insert the bibo Mouthpiece into
More informationAdam Equipment LHS SERIES. (P.N , Revision A March 2012)
Adam Equipment LHS SERIES (P.N. 7.00.6.6.0200, Revision A March 2012) Adam Equipment Company 2012 1.0 CONTENTS 1.0 CONTENTS...1 2.0 INTRODUCTION...2 2.1 INTRODUCTION...2 2.2 TECHNICAL SPECIFICATIONS...3
More informationA205 Patient Lifter - Aluminium USER MANUAL
A205 Patient Lifter - Aluminium USER MANUAL IMPORTANT: Do not use the ASPIRE A205 Lifter without having first read this manual. TABLE OF CONTENTS 1. Overview 3 2. Safety Precautions 4 3. Parts Glossary
More informationELECTRICAL. Moisture Meter User Guide
ELECTRICAL Moisture Meter User Guide Contents 1. 2-3. Welcome Section General Information & Safety Instructions 4. 5. Contents & Features General Layout 6. 7. Setting Up Installing The Battery Turning
More informationHYDRAULIC PALLET TRUCKS
HYDRAULIC PALLET TRUCKS HYDRAULIC PALLET TRUCKS MODEL Nos: PT550 GAL & PT685 GAL PART Nos: 7630234 & 7630236 OPERATION & MAINTENANCE INSTRUCTIONS 0204 Please read these instructions carefully before operating
More information1-800-222-7154 customercare@theflexbeltcare.com Designed by & Manufactured for: Bio-Medical Research Ltd., Parkmore Business Park West, Galway, Ireland. Copyright: 2015, Bio-Medical Research Ltd. All Rights
More informationHYDRAULIC PALLET TRUCK. MODEL No: PTE550 PART Nos OPERATION & MAINTENANCE INSTRUCTIONS
HYDRAULIC PALLET TRUCK MODEL No: PTE550 PART Nos 7630171 OPERATION & MAINTENANCE INSTRUCTIONS 0604 Please read these instructions carefully before operating the truck Thank you for purchasing this CLARKE
More information04979, 04980, 04981, 04982, 04983, 04984, 39054, 39055, 39056, 39057, 39225, 81459,
Hydraulic Bottle Jacks 04979, 04980, 04981, 04982, 04983, 04984, 39054, 39055, 39056, 39057, 39225, 81459, 82132. These instructions accompanying the product are the original instructions. This document
More information1 Plug one extender near your router 2 Plug one extender near your device 3 Connect your device
User Guide 1 Plug one extender near your router 2 Plug one extender near your device 3 Connect your device 500 Kit Follow the steps in this guide to set up your kit. If you need some help, see the Frequently
More information20 TONNE HYDRAULIC PRESS MODEL NO: CSA20FBT
20 TONNE HYDRAULIC PRESS MODEL NO: CSA20FBT PART NO: 7614058 OPERATION & MAINTENANCE INSTRUCTIONS WARNING: Read these instructions before using the press GC0516 INTRODUCTION Thank you for purchasing this
More informationMegohmmeter Test Probe
Megohmmeter Test Probe User Manual ENGLISH www.aemc.com CHAUVIN ARNOUX GROUP Copyright Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All rights reserved. No part of this documentation may be reproduced
More information12v / 24v Diesel Transfer Pump Kit
Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate
More informationDIAGNOSTIC TOOL BATTERY
BATTERY DIAGNOSTIC TOOL 81164 These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any subsequent
More informationTESTER SET SOCKET & VOLTAGE
SOCKET & VOLTAGE TESTER SET 82384 These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any
More informationOperators Guide: RoboSign Stop/Go Traffic Control System
Operators Guide: RoboSign Stop/Go Traffic Control System RoboSign Remote controlled Stop/Go temporary traffic control system Operators Guide NZTA Conditions - Automated Stop/Go Traffic Control System NZTA
More informationPL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:
PL900 ILLUMINATOR A PRODUCT OF DOLAN-JENNER INDUSTRIES Setup Voltage Selection: Operation Manual Read and review the instructions on the label covering the power entry module and the instructions in this
More informationExtended Battery Cabinet for Nfinity
POWER PROTECTION Extended Battery Cabinet for Nfinity USER MANUAL TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS................................... 1 ELECTROMAGNETIC COMPATIBILITY.......................................
More informationPodiatry Procedures Chair. For Models: Barrier-Free. User s Guide
Podiatry Procedures Chair For Models: 646 647 Barrier-Free User s Guide Product Information (The information below is required when calling for service.) Dealer : Date of Purchase: Model / Serial Number:
More information2 Ton - 50 Ton Bottle Jack
Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate
More informationHYDRAULIC PALLET TRUCK
HYDRAULIC PALLET TRUCK Models; PT550C & PT685C Part Nos 7630172 & 7630177 OPERATING & MAINTENANCE INSTRUCTIONS GC05/12 INTRODUCTION Thank you for purchasing this CLARKE Pallet Truck. Before attempting
More informationCordless Rechargeable Saw Instructions for Use
Technical data Voltage: DC 10.8V Weight: 1.25Kg Stroke rate: 0-2100/min Stroke: 15mm Cutting capacity: max diameter in wood 80mm / in soft metal 7mm Charging time: Between 5.0-5.5 Hours Battery: 1.3Ah
More informationSHS/SHSa SERIES. Adam Equipment. (P.N , Revision B November 2012) Software version S1.1/SA1.1
This document hosted by: www.oldwillknottscales.com Adam Equipment SHS/SHSa SERIES (P.N. 7.00.6.6.0202, Revision B November 2012) Software version S1.1/SA1.1 Adam Equipment Company 2012 1.0 CONTENTS 1.0
More informationUVR-Mi UV-air flow Cleaner - Recirculator
UVR-Mi UV-air flow Cleaner - Recirculator Medical Biological Research & Technologies Operating Manual Certificate for versions: V.2AA V.2AB 2 Contents 1. Safety Precautions 2. General Information 3. Getting
More informationOperator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:
Storage System Ultrasound Probe Cabinet Operator's Manual Manufactured by: CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA 319.248.6757 / 800.445.6741 WWW.CIVCO.COM Copyright 2018 All
More informationOperating Instructions. International English. CCS Dust Extractor
Operating Instructions International English CCS Dust Extractor Electric Cast Saw Dust Removal System Warnings & Safety Rules WARNING!: THIS EQUIPMENT MUST BE EARTHED! Danger!: Possible explosion hazard
More informationOperating instructions
Operating instructions Digital tank contents indicator DTA 10 DTA 10 DTA 10 0 4.0 m fuel oil 0 3.5 m water Read instructions before using device! Observe all safety information! Keep instructions for future
More informationOperating Instructions For The X-Seal Manual Thermal Sealer
Operating Instructions For The X-Seal Manual Thermal Sealer Version 1 Release 1 May 2009 FluidX Ltd. FluidX Ltd. Monks Heath Hall, Chelford Road, Nether Alderley, Cheshire, SK10 4SY, UK. T: +44(0) 1625
More informationInstruction manual. RP800 - HYDRAULIC actuator, load 150Kg. RP815 - LINAK actuator, load 150Kg
HYDRAULIC patient lift RP800 - HYDRAULIC actuator, load 150Kg MA RP800_805_806_ 807_810_811_815 02 A_12-2010 Electric patient lifts RP805 - LINAK actuator, load 150Kg RP806 - HIWIN actuator, load 150Kg
More informationBATTERY CHARGER INSTRUCTION MANUAL. model no. ACG112CL
model no. ACG112CL BATTERY CHARGER IMPORTANT: Please read this manual carefully before running this battery charger and save it for reference INSTRUCTION MANUAL 3 TABLE OF CONTENTS Technical specifications
More informationSmart-UPS RT External Battery Pack Stack/Rack-Mount 6U
Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U SURT192RMXLBP2 SURT192RMXLBP2J English 990-2485B 02/2009 Introduction About this UPS The American Power Conversion (APC ) SURT192RMXLBP2 external
More informationPro Series 2120 COMMERCIAL ROLLER SHUTTER OPENER
AUTOMATIC TECHNOLOGY AUSTRALIA PTY LTD Pro Series 2120 COMMERCIAL ROLLER SHUTTER OPENER OWNERS COPY Installation Instructions WARNING It is vital for the safety of persons to follow all instructions. Failure
More informationRescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference
Please dispose of Packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate
More informationMV Series Motors Operation & Parts Manual
MV Series Motors Operation & Parts Manual Models M3V, M5V, M5V-US For use with M3V s/n 101057 & below, M3V-UK s/n 103013 & below, M5V & M5V-US s/n 102972 & below. EU Declaration of Conformity Finish Thompson
More information28W WORK LAMP Model: CTL28 Part No:
28W WORK LAMP Model: CTL28 Part No: 4002905 INSTRUCTION MANUAL GC0609 INTRODUCTION Thank you for purchasing this CLARKE 28W Work Lamp. Before attempting to use the product, it is essential that you read
More informationNANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500
NANOPAC-300 & 500 Power Supply Instruction manual NANOPAC-300 & NANOPAC-500 Version 01C Feb 5th, 2014 1 Packing list NANOPAC-300 or 500-1x NANOPAC-300 Power Supply or NANOPAC-500-1x Power Cord - 1x Instruction
More informationLHS/LHSa SERIES. Adam Equipment. (P.N , Revision B November 2012) Software version L1.1/LA1.1
This document hosted by: www.oldwillknottscales.com Adam Equipment LHS/LHSa SERIES (P.N. 7.00.6.6.0200, Revision B November 2012) Software version L1.1/LA1.1 Adam Equipment Company 2012 1.0 CONTENTS 1.0
More informationInstallation manual wall-mounted distributor
EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2
More informationSIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions
SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.
More informationOperators Guide: RoboSign Stop/Go Traffic Control System
Operators Guide: RoboSign Stop/Go Traffic Control System RoboSign Remote controlled Stop/Go temporary traffic control system Operators Guide Table of Contents Operators Guide: RoboSign Stop/Go Traffic
More informationUniprep 2 Rotary scraping tool for pipes mm
Operating instructions and specifications for Uniprep 2 Rotary scraping tool for pipes 125-500mm Products by innovation not imitation Helping you make the right connections Models covered by this manual:
More informationThis manual covers the following model:
www.skcltd.com chek-mate Air Flowmeter Operating Instructions This manual covers the following model: 375-07550 Purchase Details and Service Record Thank you for choosing an SKC product. Your purchase
More informationACROBAT SWING STAND MODEL
Mounting instructions Directions for use ACROBAT SWING STAND MODEL Dr. Mach GmbH u. Co.KG, Flossmannstrasse 28, D-85560 Ebersberg Tel.: +49 (0)8092 2093 0, Fax +49 (0)8092 2093 50 Internet: www.dr-mach.com,
More informationEX Series User Manual
MODELS: EX90L T4 IIB 720 DS, EX90L T4 IIB 1440 SS, EX90L T4 IIC 720 SS EXIN LIGHT EX & INDUSTRIAL LIGHTING EX Series EX90L T4 IIB 720 DS, EX90L T4 IIB 1440 SS, EX90L T4 IIC 720 SS Contents 0. Introduction
More informationTRAFFIC DIRECTOR MR6F LED MODULE INSTALLATION MANUAL
TRAFFIC DIRECTOR MR6F LED MODULE INSTALLATION MANUAL Content Page no Unpacking 2 Different models 3 Installation 5 Maintenance 7 Warrant and return policy 8 Added supplement Wiring Diagram Separate page
More informationATV TRACK KIT. Operator s Manual Installation Instructions Service Instructions Replacement Parts List. Effective Date: October, 2012
p/n 2258-642 ATV TRACK KIT Operator s Manual Installation Instructions Service Instructions Replacement Parts List Track Assembly Kits (p/n 1436-204) Mounting Assembly Kits (p/n 1436-205) 1436-815) Effective
More informationCONTENTS. User Safety 2 Introduction and CX440 Accessories 3 CX440 Diagram 4 CX440 Keypad and Remote Control 5 Operating Instructions 6
CONTENTS User Safety 2 Introduction and CX440 Accessories 3 CX440 Diagram 4 CX440 Keypad and Remote Control 5 Operating Instructions 6 Batteries 6 Power and Horizontal Lines 7 Vertical Lines 8 Pulse (Outdoor)
More informationINSTRUCTION MANUAL. Pacific Self-locking Beam Trolleys Pacific Adjustable Angle Clamps Pacific Top Girder Clamps
INSTRUCTION MANUAL Pacific Self-locking Beam Trolleys Pacific Adjustable Angle Clamps Pacific Top Girder Clamps IMPORTANT Please read this instruction manual before using these products. This manual contains
More informationAIM LED LIGHT (wall mount)
AIM LED LIGHT (wall mount) Installation Manual AIM LED LIGHT (wall mount) INTRODUCTION Lights in the AIM Series are designed to give the professional health care market superior performance, reliability
More informationLIFT-O-FLEX Lift-O-Turn LIFTER USER MANUAL. We re here for you. PLACE SERIAL NUMBER LABEL HERE. Have Questions?
PLACE SERIAL NUMBER LABEL HERE LIFT-O-FLEX Lift-O-Turn LIFTER USER MANUAL DOCUMENT ID: 01022018 Have Questions? We re here for you. R ON I READ BEFORE YOU BEGIN It is important that you read and understand
More informationModel AS-FM64 Wall Mount. Full Motion Television Wall Mount
Model AS-FM64 Wall Mount Full Motion Television Wall Mount Getting Started Introduction Congratulations on the purchase of your new Audio Solutions AS-FM64 Television Wall Mount. For maximum benefit, please
More informationuser instructions and warranty airflo (battery version) freedom through lightweight solutions
user instructions and warranty airflo (battery version) freedom through lightweight solutions The irflo by Mangar International, is a low pressure air compressor, which has been designed for use with Mangar
More informationIN & TM Series User Manual
IN & TM Series User Manual Models: IN3500LB, IN1600L, IN1600LB, IN120L, IN120LB, TM120L, TM120LB IN Series User Manual IN120L, IN120LB, IN1600L, IN160000LB, IN3500LB, TM120L & TM120LB Contents Equipment
More informationUSER MANUAL. Tides La Mer Treatment Table Rev A 3/28/19. *all tables shown with optional accessories and/or finishes
USER MANUAL Tides La Mer Treatment Table *all tables shown with optional accessories and/or finishes 1-400-0041 Rev A 3/28/19 Living Earth Crafts 2019, All Rights Reserved Legal Notice The information
More informationThe EFL 2000/1 & 2 User Guide Test Sieve Shaker. Contents
The EFL 2000/1 & 2 User Guide Test Sieve Shaker ISSUE 04-02 Contents Description Page 1 Setting Up: 2-8 Unpacking 2 Assembly 3 Clamping Assembly 4 Electrical Connections 5 Sieve Stacking 6 8 Operating
More information230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230
230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230 PART NO: 7160050 OPERATION & MAINTENANCE INSTRUCTIONS GC0816 INTRODUCTION Thank you for purchasing this CLARKE Pump. The DFTP230 pump is a self-priming rotary
More informationCommunity Bed U S E R G U I D E
Community Bed U S E R G U I D E Overview The BetterLiving Community Bed by Novis offers the practical convenience of a nursing bed coupled with design simplicity. Ideal for aged care or home environments,
More informationLLS-2054BE. Smart Battery Pack Operator Manual. ST Technologies 6018 Bowdendale Avenue Jacksonville, FL USA
LLS-2054BE Smart Battery Pack Operator Manual ST Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216 USA Customer Service: 904 208-2290 Toll Free 877-814-2237 EC REP RMS UK, Ltd. 28 Trinity Road
More informationINSTRUCTIONS FOR USE. Rx Only
INSTRUCTIONS FOR USE - HOSE ASSEMBLY Rx Only Basic matrix shown. Consult the Ohio Medical website for full matrix or contact your Ohio Medical representative. The product package label contains your product
More informationINSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU)
INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU) Model Number: 41756 (100 125Vac) 41757 (220 240Vac) Manufactured in the United Kingdom CONTENTS Chapter Page Specification 3 What the TAU does
More informationHST -LS Interlocking device (Translation of Original Manual)
Installation and Operating Manual for Components HST -LS Interlocking device (Translation of Original Manual) HST-LS Ident.-No.: 10268 HST-LS Ident.-No.: 10269 HST-LS, pictured Ident-Nr. 10269 The image
More informationInstallation Manual TWM Performance Short Shifter Cobalt SS/SC, SS/TC, HHR SS, Ion Redline and Saab 9-3
Page 1 Installation Manual TWM Performance Short Shifter Cobalt SS/SC, SS/TC, HHR SS, Ion Redline and Saab 9-3 Please Note: It is preferable to park on a flat surface, as you will have to engage and disengage
More informationHALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &
HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: 5460600 & 5460595 OPERATING & MAINTENANCE INSTRUCTIONS GC0610 INTRODUCTION Thank you for purchasing this CLARKE Halogen Floodlight. Before attempting
More informationSTRX-9 100% TAKE CONTROL INSTRUCTION MANUAL READY-TO-RUN. w/ Adult Supervision
STRX-9 w/ Adult Supervision INSTRUCTION MANUAL 18005 100% READY-TO-RUN TAKE CONTROL Index Included Items Important Notes Battery Installation Charging Instructions Transmitter/Receiver Binding Basic Controls
More informationIntroduction. The words WARNING, CAUTION and NOTE carry special meanings and should be carefully reviewed.
Operations/ Maintenance Manual Important Information File in your maintenance records Medical Visum Exam Light Model LL305 For parts or technical assistance call 800 327 0770 (option 2) Table of Contents
More informationRe.Formance Line INSTRUCTION MANUAL 1703
Re.Formance Line INSTRUCTION MANUAL 1703 320.8779.02 / 1703 Re.Formance Line Table of contents 1. Overview... 3 1.1 Re.Forma Hi.... 3 1.2 Re.Forma... 3 1.3 Re.Forma Lite.... 3 2. Notes... 4 2.1 Warranty
More informationOWNER'S MANUAL. Royal Sovereign International Inc. RET Desk Series
OWNER'S MANUAL RET Desk Series Read all instructions carefully before use. For any Customer Support needs please choose the Customer Support tab on www.royalsovereign.com Royal Sovereign International
More informationRENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev
Manual Part #: M-3022 Feeder AF371 Operations Rev. 3-16-04 1 RENA AF371 Feeder YOUR RENA AF371 IS DISTRIBUTED BY RENA SYSTEMS INC. SERVICE AND SUPPORT FOR THIS PRODUCT IS PROVIDED BY YOUR RENA DEALER.
More information