ACROBAT SWING STAND MODEL
|
|
- Lillian Wheeler
- 6 years ago
- Views:
Transcription
1 Mounting instructions Directions for use ACROBAT SWING STAND MODEL Dr. Mach GmbH u. Co.KG, Flossmannstrasse 28, D Ebersberg Tel.: +49 (0) , Fax +49 (0) Internet: Edition / Bak Page 1/20
2 List of contents 1. Safety instructions... Page 3 2. Brief description of the stand... Page 6 3. Mounting instructions... Page Mounting the stand... Page Mounting the stand foot... Page Mounting the stand tube to the stand foot... Page Mounting the spring arm and the lamp head... Page Mounting the spring arm to the stand tube... Page Mounting the lamp head to the spring arm... Page Installation of the stand... Page Cleaning... Page Initial operation and Maintenance... Page Activity at initial operation and maintenance work... Page Changing the power supply... Page Adjusting the spring force (LED 120/ LED 130)... Page Adjusting the spring force for LED Page Maintenance of the securing segment... Page Data... Page Technical data... Page Environmental conditions... Page Disposal... Page CE- mark... Page Dimensions and range of movement... Page LED 120 / LED Page LED Page Spare parts... Page Spare parts list... Page Edition / Bak Page 2/20
3 1. Safety instructions Please read these mounting instructions and directions for use carefully before working with the device. In this way you will profit from all advantages of the device and save yourself and other persons from harm. WARNING! This device has not been designed for use in potentially explosive areas. According to the Medical Device Regulation the Stand is classified under class I. The manufacturer is only responsible for operational safety of the stand foot when repairs and modifications are carried out by his own staff or by persons who guarantee compliance with the safety regulations. No modification of the stand model is allowed! The manufacturer is not responsible for damage to persons or property caused by incorrect or improper use, or when used for incorrect purposes. Repairs to the stand and special installation work on the sliding contacts should only be carried out by Dr. Mach or a company expressly authorized by Dr. Mach. Make sure that the stand is in perfect working order before every use. The stand foot must be connected to the mains, until it has been fully assembled and installed. Connect the stand only to a correctly installed socket with earthing contact. The socket used must be installed according to the requirements of IEC and VDE Please keep this mounting instructions and directions for use carefully in the vicinity of the equipment so that you can later refer to safety instructions and important information at any time Edition / Bak Page 3/20
4 Symbols and notes used in this user manual: This symbol means possible hazard sources. Please observe also the safety remarks and the hazard specifications mentioned in the mounting instructions and user manuals from Ondal company. This symbol means possible hazard caused by electric current. Please observe also the safety remarks and the hazard specifications mentioned in the mounting instructions and user manuals from Ondal company. This symbol refers to important mounting indications, useful information and operation hints. Temperature range for transport and storage Indication for disposal CE- mark Edition / Bak Page 4/20
5 Symbols and notes used on the device: This symbol indicates to observe the user manual. Protective conductor Serial number of the product Article number of the product Address of manufacturer / distributor of the product CE- mark This symbol indicates the maximum permissible carrying load on the stand. The indicate of kg shows the weight of the stand foot. This symbol means, note the maximum payload Edition / Bak Page 5/20
6 2. Brief description of the stand Acrobat Swing intended use: The stand is designed for carrying and positioning of medical examination lamps up of 1,9 kg up to 4,5 kg and to supply the lamps with electricity. Essential Performance: - The stand is designed for continuous operation. - The lamps works with 24V DC. - The maximum load of the stand does not exceed 4,5 kg. 3. Mounting instructions 3.1 Mounting the stand 1 Extent of supply for stand foot: 1 stand foot 1 stand tube 1 spring arm 2 3 Mounting accessories: 2 antistatic rollers with brakes 2 rollers without brakes 1 colour foil 2 plastic half-rings 1 plastic bushing 1 security segment 1 washer 1 retaining ring 1 pliers for retaining ring Mounting the stand foot To mount the stand foot proceed as follows: Guide the two antistatic rollers 1 with brakes through the ring terminal of the potential compensation line 2 and insert the two rollers completely into the stand foot 3. Insert the rollers without brakes completely into the stand foot. Check if the rollers are firmly fixed. Pull off the adhesive foil 4, lay colour foil into the eye-shaped depression of the stand foot and press evenly to surface. Pull off protective foil Edition / Bak Page 6/20
7 3.1.2 Mounting the stand tube to the stand foot 2 3 Nase The stands for LED 120 / LED 130 / LED 150 are equipped with an additional weight 5 on their bottom side. Loosen screw (with lock washer) 6 at the stand tube 2 and remove. Insert stand tube 2 in such a way, that the recess of tube 3 fits into the nose of stand foot 4 and tube 3 can no more be rotated.. Check if the stand tube is firmly fixed. Insert screw (with lock washer) 1 and tighten. Caution: If the stand has not be fixed properly as described above, it will tip over Press the plastic semi-rings 7 into the stand foot 4. Screw in recessed head screw screws 8 and check if the semi-rings are firmly fixed Edition / Bak Page 7/20
8 3.2 Mounting the spring arm and the lamp head Mounting the spring arm to the stand tube For mounting the spring arm proceed as follows: Unscrew recessed head screw 1, pull off cover cap 2 and remove it by pulling it upward. Insert spring arm journal, place washer 4 and secure the spring arm with retaining ring 5. Check if the retaining ring 5 is firmly fixed. Caution: If not handled properly the retaining ring 5 gets loose and the spring arm falls off the connection. Always mount washer 4. Close electrical connection 6. Replace cover cap 2 and fix it with recessed head screw Edition / Bak Page 8/20
9 3.2.2 Mounting the lamp head to the spring arm ATTENTION! Notice the rated voltage information! Coupling journal Sticker with voltage information Lamp bow Each lamp has a red sticker applied near the coupling journal at the lamp bow. The sticker shows the rated voltage of the lamp. Connect the lamp only to the prescribed voltage, to avoid irreparable damage (e.g. the electrical components). Following rated voltage is usual: 24-28V DC After mounting the lamp take off the sticker and dispose it, otherwise it could fall down in the OTfield after some time! Attention: If the spring arm is pushed downwards (the arm is under spring tension) it may bounce up and cause harm. While mounting the lamp head no other persons are allowed to be within the swivel range of the spring arm. Note: Maximum permissible load of spring arm 2,8 kg / 4,5 kg! Edition / Bak Page 9/20
10 Do not remove screw 13, it is designed to fix the sliding contact and provides earthling! Mounting the lamp LED 120 / LED 130 / LED 150 to the spring arm Loosen brake screw 1, so the plastic bushing 2 can be slipped easy onto the spring arm. Slip plastic bushing 2 onto the spring arm to overlap slots 3. Check if the journal 4 of the lamp is greased. Insert the greased journal 4 of the lamp and insert security segment 5 completely into slot 3, so that the security segment leads in groove 6. Rotate plastic bushing 2 by 180 up to the provided drilling for the brake screw and screw in brake screw 1 until you reach the desired brake effect for lamp head 4. Check if lamp head 4 is firmly fixed ATTENTION! It is absolutely necessary to mount this securing segment! Edition / Bak Page 10/20
11 3.3 Installation of the stand 1. Take the stand to the working place and arrest the two rollers with brakes. Caution: Do not touch damaged electrical parts. Danger of electrical shock! If you notice a damaged mains cable or plug do not plug in. Call your service number and report the damage. 2. Check if mains plug or mains cable are damaged. 3. Please check that an earthed socket is available within the working area of the lamp. The socket to be used for the lamp must be installed according to the requirements stipulated by the IEC or VDE Do not overrun any objects on the floor or the mains cable. The stand might tip over. 4. Cleaning Before doing any cleaning work turn off the lamp, draw plug from mains and make sure that the lamp cannot be switched on again. Please ensure, that no disinfection liquid flows into the joints or lamp head. The surface of the stand can be easily kept clean by simply wiping with a wet cloth. You can use conventional cleaning agents. Caution: In order to prevent any damage at plastic parts do not use scouring agents or alkaline, acidic and alcoholic cleaning agents. For cleaning proceed as follows: Draw plug from mains. Wipe the surface of the stand with a wet cloth. As a cleaning agent you can use water or a soap solution (washing-up liquid). 5. Initial operation and Maintenance Note: Before doing any maintenance work, turn off the lamp, draw plug from mains and make sure, that the lamp cannot be switched on again. Check the fixing screw at the lower part of the stand once a year and, if necessary, adjust. Check and grease the security segment once a year. Preventive maintenance of the light should be done every two years. This includes a technical and mechanical check-up. Please observe also the mounting instructions and instructions for the carrying systems. These instructions can contain statements for different maintenance intervals. 5.1 Activity at initial operation and maintenance work The following maintenance work / tests has / have to be done: check on defects in paint work; check on fissures at plastic parts; check on deformation of the suspension. check the function; electrical safety test; Edition / Bak Page 11/20
12 check the suspension; 5.2 Exchanging the power supply In case of the mobile lights LED 120 / LED 130 and LED 150 the power supply is located inside the handle of the mobile stand. For exchanging the power supply proceed as follows: Disconnect the light from mains. Loosen the two fixing screws of the mobile stand handle (required tool: cross-head screwdriver). Fold the handle apart. Disconnect the power supply cables from the electrical terminals. Loosen the two fixing screws of the power supply. Remove the power supply. Mount the new power supply in reverse order and connect the cables. Check the function of the light Edition / Bak Page 12/20
13 5.3 Adjusting the spring force of LED 120 / LED 130 Springs are wearing parts, thus the spring force can decrease in time and must be readjusted. Note: Set the spring force in such a way, that the spring arm with the lamp head holds its position at every set height B A In case the spring arm with the lamp moves down on its own, proceed as follows: Remove lateral cover A. The adjusting screw (B) for the spring force is visible now. Push the lamp and spring arm upwards as much as possible, so the spring is without charge. Insert a slotted screwdriver into the screw B. Turn the adjusting screw to the left (anticlockwise), until the lamp holds its position at every set height. B In case the spring arm with the lamp moves up on its own, proceed as follows: Remove lateral cover A. The adjusting screw (B) for the spring force is visible now. Push the lamp and spring arm upwards as much as possible, so the spring is without charge. Insert a slotted screwdriver into the screw B. Turn the adjusting screw to the right (clockwise), until the lamp holds its position at every set height Edition / Bak Page 13/20
14 5.4 Adjusting the spring force of LED 150 Take out screw (1) and remove cover (2) (Fig.1). Move the spring arm to a position where the crossdrilled nut (3) is visible through one of the two slots (4) (Fig.2). Take the pin (5) from the accessories and insert it into one of the holes on the circumference of the nut such that it can be turned into the desired direction (Fig.3). If the spring arm drops: The spring force is too low. - The adjustment nut (3) must be rotated to the right (clockwise facing the rear joint) (Fig.3). If the spring arm rises: The spring force is too high: - The adjustment nut (3) must be rotated to the left (counterclockwise - facing the rear joint) (Fig.4). 5.5 Maintenance of the securing segment Dismount the lamp head in reverse order of mounting (see chapter 3.2.2). Check the thickness of the segment. It must be at least 1,5 mm. In case the thickness of the segment is less than 1,5mm it has to be changed Edition / Bak Page 14/20
15 Grease the segment and the coupling journal of the lamp. Mount the lamp to the spring arm, as described in chapter Edition / Bak Page 15/20
16 6. Data 6.1 Technical datas Mobile stand LED 120 LED 130 LED 150 Rated voltage 24V DC 24V DC 24V DC Power consumption 18W 28W 35W Rated current at 0,75A 1,17A 1,46A Protection class I. I. I. 6.2 Environmental conditions 63BOperation Min. Max. Temperature +10 C +40 C Relative atmospheric humidity 30 % 75 % Air pressure 700 hpa 1060 hpa 64BTransport / storage Min. Max. Temperature +10 C +40 C Relative atmospheric humidity 30 % 75 % Air pressure 700 hpa 1060 hpa 56BReferences on the package Temperature range for transport and storage Atmospheric humidity for transport and storage Air pressure for transport and storage Edition / Bak Page 16/20
17 7. Disposal The stand doesn t contain any dangerous goods. The components of the stand should be properly disposed at the end of its shelf-life. Make sure, that the materials are carefully separated. The electrical conducting boards should be submitted to an appropriate recycling proceeding. The stand and rest of the components should be disposed according to the contained materials. 8. CE- mark The stands comply to the standards 93/42/EEC for medical products of the European Community s Council. Dr. Mach applies the standard EN Dr. Mach GmbH is certified according to EN ISO 13485: AC: Edition / Bak Page 17/20
18 9. Dimensions and range of movement 9.1 LED 120 / LED Edition / Bak Page 18/20
19 9.2 LED Edition / Bak Page 19/20
20 10. Spare parts , Edition / Bak Page 20/20 15
21 11. Spare parts list Item Qty. Name EDVNO Remarks 01 1 Decorative foil Sheet metal screw M2x9 DIN Plastic semi-circular ring Cover RAL LED lights 06 1 Device fuse Brake Screw Screw M3x4 DIN 966: Ni for Cover Cover RAL LED lights 10 1 Side covering left Stopper Handle half RAL LED lights 14 1 Four-foot base with weighting plate Roller Roller with brake Connecting cable with plug Swing - spring arm Stand 1,8-2,7 kg for LED 120/ Swing-spring arm Stand 3,5-4,5 kg for LED Screw M3x10 D7985:Zn Lock washer A3, Edition / Bak Page 21/20
STAND MODEL FOR MACH M2
Mounting instructions Directions for use STAND MODEL FOR MACH M2 Stand lamps: Mach M2... Mach M2 F... Order No. 170 120 1300 Order No. 170 230 1300 GmbH u. Co. KG, Flossmannstrasse 28, D-85560 Ebersberg
More informationACROBAT SWING STAND MODEL
Mounting instructions Directions for use ACROBAT SWING STAND MODEL Stand lamps: Mach 120... Mach 120F... Mach 130... Mach 130F... Mach LED 120... Mach LED 120F... Mach LED 130... Mach LED 130F... Order
More informationCEILING ATTACHMENT FOR MACH M2
Mounting instructions Directions for use CEILING ATTACHMENT FOR MACH M2 Ceiling lamps: Mach M2... Mach M2 F... Order No. 170 120 3330 Order No. 170 230 3330 GmbH u. Co., Flossmannstrasse 28, D-85560 Ebersberg
More informationCEILING ATTACHMENT ACROBAT SWING
Mounting instructions Directions for use CEILING ATTACHMENT ACROBAT SWING Dr. Mach GmbH u. Co.KG, Flossmannstrasse 28, D-85560 Ebersberg Tel.: +49 (0)8092 2093 0, Fax +49 (0)8092 2093 50 Internet: HUwww.dr-mach.com
More informationSTAND FOOT - STAND TUBE
Mounting instructions Directions for use STAND FOOT - STAND TUBE Stand lamps: Mach 130 / Mach 130F Soloflex Triaflex / Triaflex R96 Trigenflex / Trigenflex R96 GmbH u. Co., Flossmannstrasse 28, D-85560
More informationDr. Mach Lamps and Engineering
Mounting instructions MACH LED 3MC/SC STAND MODEL Mach LED 3MC stand lamp Order No. 370 530 1200 Mach LED 3SC stand lamp Order No. 360 530 1200 Accessories Surcharge for integrated laser pointer Order
More informationMounting instructions Directions for use MAKROLUX. Halogen-spot lamp for consulting room and hospital
Mounting instructions Directions for use MAKROLUX Halogen-spot lamp for consulting room and hospital Stand model with five-feet base, design without heat protection filter 1100 1012 00 Stand model with
More informationDr. Mach Lamps and Engineering
Directions for use SOLOFLEX Stand lamp one-handed height adjustment Order No. 1281 3011 00 Stand lamp - swivel arm Order No. 1281 3012 00 Wall lamp Order No. 1281 3021 00 Ceiling lamp for room heights
More informationDr. Mach Lamps and Engineering
MOUNTING INSTRUCTIONS Ceiling attachment Wall attachment Applies to: Soloflex Triaflex Trigenflex Quintaflex Mach 120 Mach 130 Mach M3 Mach M5 Mach 380 Mach 400 Mach 500 Tool and instrument trays GmbH
More informationDr. Mach Lamps and Engineering
MOUNTING INSTRUCTIONS Ceiling attachment Wall attachment Applies to: Soloflex Triaflex Trigenflex Quintaflex Mach 120 Mach 130 Mach M3 Mach M5 Mach 380 Mach 400 Mach 500 Tool and instrument trays GmbH
More informationDr. Mach Lamps and Engineering
DIRECTIONS FOR USE Triaflex Stand lamp Order No. 3001 1012 00 Wall lamp Order No. 3001 1021 00 Single ceiling lamp Order No. 3001 1031 25 Order No. 3001 1031 30 Ceiling lamps combinations Emergency power
More informationDr. Mach Lamps and Engineering
Mounting instructions Directions for use EMERGENCY POWER LAMP Triaflex / Triaflex R96 emergency power lamp Trigenflex / Trigenflex R96 emergency power lamp Mach M3 F- / DF- / F/H- / DF/H emergency power
More informationOPERATING INSTRUCTIONS
Emergency Cord Switch Type LRS 004 Device identification no.: 93.046 690.004 OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national regulations.
More informationIU0U automatic charger Read these instructions carefully before the installation and commissioning and keep them in a safe place. Pass it on to the buyer in case of the further sale of the system. Contents
More informationElectropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN
Electropneumatic Converters i/p Converters Type 6111 Fig. 1 Type 6111 in standard version Fig. Type 6111 mounted on a supply air manifold Fig. 3 Type 6111 in field enclosure Mounting and Operating Instructions
More informationHEINE NT4 MED V
HEINE NT4 MED 113594 2018-01-23 V-200.00.601 HEINE NT4 Please read and follow these instructions for use and keep them for future reference. Intended Use The HEINE charger NT4 is to be used exclusively
More informationService manual. English. F5 Corpus
Service manual English F5 Corpus Introduction The Service Manual is intended for technical personnel who maintain and repair power wheelchairs. It is important that anyone who performs maintenance and
More informationSpear & Jackson 37 cc Petrol Chainsaw Original Operating Instructions
Spear & Jackson 37 cc Petrol Chainsaw Original Operating Instructions Assembly Manual After Sales Support UK/Ireland 0151 649 1500 Republic of Ireland 1890 946 244 Web www.einhell.co.uk Important - Please
More informationSERVICE MANUAL US. Permobil M300/M400. Power Wheelchair
SERVICE MANUAL US Permobil M300/M400 Power Wheelchair How to contact Permobil Head Office of the Permobil group Produced and published by Permobil AB, Sweden Version 2, 2011-06 Article no.: 205261-US-0
More informationFitting Instructions ECE. type-approved. 1 Component overview 2 Warnings 3 Assembling 4 Light bulb replacement. Info:
ENG 10/02 Fitting Instructions ECE type-approved 1 Component overview 2 Warnings 3 Assembling 4 Light bulb replacement Info: www.kellermann-online.com Dear customer, Thank you for purchasing the BL_1000.
More informationMounting and Operating Instructions EB EN. Type 3271 and Type 3277 Pneumatic Actuators. Actuator areas: 175v2, 350v2, and 750v2 cm²
Type 3271 and Type 3277 Pneumatic Actuators Actuator areas: 175v2, 350v2, and 750v2 cm² Translation of original instructions Type 3271 (left) and Type 3277 (right) Pneumatic Actuators Mounting and Operating
More informationPROFESSIONAL CORDLESS IMPACT SCREWDRIVER
PROFESSIONAL CORDLESS IMPACT SCREWDRIVER Model CIS00 Part No 4500625 OPERATING & MAINTENANCE INSTRUCTIONS GC0309 INTRODUCTION Thank you for purchasing this CLARKE Impact Screwdriver. Before attempting
More informationInstallation manual wall-mounted distributor
EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2
More informationBelt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS
Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national regulations. Conformity has been
More informationOPERATING INSTRUCTIONS
Conveyor Belt Misalignment Switch Type MRS 001 Device Identification No.: 91.055 301.001 OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national
More informationHydraulic Impact Wrench Type
M a s c h i n e n f a b r i k G m b H Hydraulic Impact Wrench Type 6 1520 0010 Illustration can differ from the original Operation and Maintenance Manual 615200010_en_Version_03 Page 1 of 19 TECHNICAL
More informationRopox Shower & Changing Bed
Ropox Shower & Changing Bed Pre-install / install guide General information Product information It is important to read this manual before mounting and daily use. Product : Ropox Shower & Changing Bed,
More informationSPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL
SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL MOTORTECH Tools & Test Equipment for Ignition Systems P/N 01.10.019 Rev. 01/2013 Copyright Copyright 2012 MOTORTECH GmbH. All rights reserved. Distribution
More informationType Pneumatic Control Unit. Operating Instructions
Pneumatic Control Unit Operating Instructions We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques. Bürkert Werke GmbH
More informationType Pneumatic Control Unit. Operating Instructions
Pneumatic Control Unit Operating Instructions We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques. Bürkert Werke GmbH
More informationRe.Formance Line INSTRUCTION MANUAL 1703
Re.Formance Line INSTRUCTION MANUAL 1703 320.8779.02 / 1703 Re.Formance Line Table of contents 1. Overview... 3 1.1 Re.Forma Hi.... 3 1.2 Re.Forma... 3 1.3 Re.Forma Lite.... 3 2. Notes... 4 2.1 Warranty
More informationTechnical Manual Electrical Power Supply System T4002
Technical Manual Electrical Power Supply System T400 MOZELT GmbH & Co. KG Please observe the following safety information and recommendations before start-up! Copyright: MOZELT GmbH & Co. KG, D-4769 Duisburg
More informationCompact System NRGS 11-2 NRGS Original Installation Instructions English
Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive
More informationOPERATING INSTRUCTIONS
Emergency Cord Switch Type PRS Device identification No.: 91.054 033.001, /.101 and /.201 OPERATING INSTRUCTIONS 2 CE Sign and Conformity The device meets the requirements of the valid European and national
More informationLinear Luminaire with LED
Linear Luminaire with LED Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3
More informationTranslation of the Original operating instructions Lifting device Z 70 /...
Translation of the Original operating instructions Lifting device Z 70 /... Content 1. Lifting device / Correct use according to regulations 2. Basic principles 3. General information 4. Special remarks
More informationRegister your instrument! HeatSealer S100. Operating manual
00N) manual Register your instrument! www.eppendorf.com/myeppendorf Operating manual Copyright 2015 Eppendorf AG, Germany. All rights reserved, including graphics and images. No part of this publication
More informationMounting and Operating Instructions EB EN. Type 3372 Electropneumatic Actuator. Actuator area: 120 and 350 cm² With Type 3725 Positioner
Type 3372 Electropneumatic Actuator Actuator area: 120 and 350 cm² With Type 3725 Positioner Translation of original instructions Type 3372 with 120 cm² actuator area Type 3372 with 350 cm² actuator area
More informationInstallation Guide VHM Wall Mount Kit for Philips MX600/700/800 and MP60/70 IntelliVue
Installation Guide VHM Wall Mount Kit for Philips MX600/700/800 and MP60/70 IntelliVue The purpose of this guide is to: 1. Describe attachment of Table Top Mount to Mounting Adapter (page 2). 2. Describe
More informationOriginal Operating Manual
matev GmbH Nürnberger Str. 50 90579 Langenzenn T +49 (0) 9101 9087-0 F +49 (0) 9101 9087-20 info@matev.eu www.matev.eu Original Operating Manual Snow blade SRM-FB 120 CD Angle adjustment mechanical Version
More informationHD18F2M1.
HD18F2M1 www.blackanddecker.com 3 2 1 5 A 4 5 B 4 7 10 9 C 4 6 D 4 8 1 11 12 E 2 F 3 2 G H 13 I 14 13 14 K 3 J 3 L M 16 15 4 Intended use Your Black & Decker hand held vacuum cleaner has been designed
More informationTHIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL. WELLS ENGINE UNIT 230 VOLT Product No. U905, U906, U907, U908
DENTAL, INC. TECHNICAL BULLETIN U807-022510 5860 FLYNN CREEK ROAD READ ALL INSTRUCTIONS P.O. BOX 106 BEFORE PROCEEDING COMPTCHE, CALIFORNIA, U.S.A. 95427 SAVE THIS FOR FUTURE REFERENCE THIS PRODUCT IS
More informationTechnical Description Edition 2007 Mounting, maintenance and repair of propshafts with flanged universal joints
Technical Description Edition 2007 Mounting, maintenance and repair of propshafts with flanged universal joints 1. Recommendations Assembly, disassembly, maintenance and repair of propshafts should be
More informationType Operating Instructions. Bedienungsanleitung Manuel d utilisation
Type 0131 2/2- or 3/2-way solenoid valve 2/2- oder 3/2-Wege-Magnetventil Électrovanne 2/2 ou 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating
More informationHydraulic Motors. Radial Piston Motors with fixed displacement Series RM...X Vg = 250 cm³/u cm³/u. Repair manual. Doc.-No.
Hydraulic Motors Radial Piston Motors with fixed displacement Series RM...X Vg = 250 cm³/u - 900 cm³/u Doc.-No. HM3-005 UK Seite 2 Table of contents 1. General... 3 2. Dismantling the distributor unit...
More informationSM6. instructions for use. GAM cubicle (1250A) MV distribution factory built assemblies at your service. Anglais
SM6 Anglais MV distribution factory built assemblies at your service instructions for use GAM cubicle (1250A) foreword... 3 symbols and conventions... 3 as per iso 3864---2... contact the Schneider Electric
More informationOPERATING INSTRUCTIONS INDEPENDENT WHEEL SUSPENSION RL 75 E/EC FRONT AXLE/TAG AXLE RL 75 A
INDEPENDENT WHEEL SUSPENSION RL 75 E/EC FRONT AXLE/TAG AXLE RL 75 A 587.97.90 en Preface This documentation has been developed for specialized staff trained by ZF Friedrichshafen AG for repair and maintenance
More informationType 3571 Pneumatic Actuator. Actuator areas: 27 in² 54 in² 116 in². Original instructions. Mounting and Operating Instructions EB 8820 EN
Type 3571 Pneumatic Actuator Actuator areas: 27 in² 54 in² 116 in² Original instructions Mounting and Operating Instructions Edition April 2016 Note on these mounting and operating instructions These mounting
More informationPET UNIT DOSE TABLE INSTALLATION MANUAL FN: Rev A 1/18
PET UNIT DOSE TABLE INSTALLATION MANUAL 042-448 FN: 09-243 Rev A 1/18 Pet Unit Dose Table This manual covers installation procedures for the following products: 042-448 Table, PET, Unit Dose 2 Biodex Medical
More informationPRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual
PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com CONTENTS PRM-2 & PRM-3 1. Warranty...3
More informationOperating Instructions. International English. CCS Dust Extractor
Operating Instructions International English CCS Dust Extractor Electric Cast Saw Dust Removal System Warnings & Safety Rules WARNING!: THIS EQUIPMENT MUST BE EARTHED! Danger!: Possible explosion hazard
More information2006 MINI Cooper SUSPENSION Wheels & Tires - Repair Instructions - Cooper (1.6L) R50/W10 & Cooper S
WHEELS 2002-05 SUSPENSION Wheels & Tires - Repair Instructions - Cooper (1.6L) R50/W10 & Cooper S 36 10 300 REMOVING OR INSTALLING FRONT OR REAR WHEEL NOTE: For Special Tool identification, see WHEEL AND
More informationMounting and Operating Instructions EB EN. Type 3271 Pneumatic Actuator. Actuator area: 1000 cm². Translation of original instructions
Type 3271 Pneumatic Actuator Actuator area: 1000 cm² Translation of original instructions Type 3271 Pneumatic Actuator Mounting and Operating Instructions Edition April 2018 Note on these mounting and
More informationInstruction Manual. Ex-Time 40 / 50
Instruction Manual Ex-Time 40 / 50 Contents 1. Introduction 13 2. Safety Advice 13 3. Faults and Damage 13-14 4. Safety Regulations 14 5. Ex-Data 14-15 6. Technical Data 15-16 7. Use and Application /
More informationMounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type
Electropneumatic Converters i/p Converter Type 3913-0001 Fig. 1 Type 3913-0001 Electropneumatic Converter with pressure gauge and bracket Mounting and Operating Instructions EB 3913 EN Edition August 2011
More informationInstallation Guide. Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit
Installation Guide Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit The purpose of this guide is to: 1. Describe attachment of Table Top Mount to Mounting Adapter. 2. Describe attachment of Mounting
More informationUser Manual Rittal PMC UPS 6kVA
User Manual Rittal PMC UPS 6kVA Germany Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Tel.: ++49-27 72-5 05-0 Fax: ++49-27 72-5 05-23 19 Internet: www.rittal.de 26 Contents 1. Introduction...
More informationOperating Instructions
Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3
More informationOperating Manual Hot Melt Applicator. Tec 4500B / Tec 4500S
Operating Manual Hot Melt Applicator Tec 4500B / Tec 4500S Table of Contents 1 General 4 1.1 Scope of use 4 1.2 Technical data 4 2 Safety instructions 5 2.1 Potential hazards 5 2.2 Instructions for safe
More informationMounting and Operating Instructions
Mounting and Operating Instructions EB 8310-6 EN Translation of original instructions Type 3271 Type 3277 Type 3271 and Type 3277 Pneumatic Actuators Actuator area: 240, 350, and 700 cm² Edition March
More informationOperatingmanual. Mehrsprachige Anleitung unter Multilingual manuals at. pro BENNING TRITEST BENNING BENNING BENNING.
Operatingmanual Mehrsprachige Anleitung unter www.benning.de Multilingual manuals at TRITEST pro TRITEST pro D F 8 9 J 1 2 3 6 7 4 5 TRITEST pro T.-Nr: 10115280.01 Stand: 10-2014 10/ 2014 TRITEST pro Operating
More informationLinear Luminaire for Fluorescent Lamps
Linear Luminaire for Fluorescent Lamps Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information regarding
More informationHALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &
HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: 5460600 & 5460595 OPERATING & MAINTENANCE INSTRUCTIONS GC0610 INTRODUCTION Thank you for purchasing this CLARKE Halogen Floodlight. Before attempting
More informationInstallation manual portable distributors
EN Installation manual portable distributors EN 60003206 Issue 11.2016 15/11/2016 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2 Intended
More informationUser manual. Model Mini, Small, Medium and Large
User manual Model Mini, Small, Medium and Large 2 Contents Introduction..3 CE marking and labels...3 Safety precautions..3 Prior to first use 4 Meywalk 4 parts...4 Joining the top part and bottom frame.5
More informationOperating Manual for extrusion valve MMKD-40 KV/LV/LVP
Operating Manual for extrusion valve MMKD-40 KV/LV/LVP Read this manual carefully before installing, operating or servicing this equipment. Keep always handy for further use. ALFRED SCHÜTZE Apparatebau
More informationExchange of rollers from the XTS-Mover
Service documentation for AT901-0050-0550 and AT9011-00x0-0550 Version: Date: 1.0 0.10.017 Table of contents Table of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1. Documentation issue
More informationGlobe Control Valve Series 1a
Maintenance Globe Control Valve Series 1a are subject to alteration without notice. The text and illustrations do not necessarily display the scope of supply or any ordering of spare parts. Drawings and
More informationArmon Edero. User manual
User manual Armon Edero Foreword.... 2 Symbols used 2 Intended use.... 2 About the Armon Edero... 2 Mounting options of the Edero 2 Braces. 3 How to set up the Armon Edero.. 3 How to attach the brace to
More informationMaintenance Information
80234313 Edition 1 June 2006 Air Grinder, Die Grinder, Sander and Belt Sander Series G1 (Angle) Maintenance Information Save These Instructions WARNING Always wear eye protection when operating or performing
More informationBowl feeder WV401-1 / Translation of operating and installation instructions
Bowl feeder WV401-1 / 402-1 Translation of operating and installation instructions Copyright by Afag GmbH This operation instruction applies to: Bowl feeder WV401-1 Bowl feeder WV402-1 Type 230 V / 50
More informationExplosion protected terminal boxes type, GHG 72.
1 Technical data 1.1 Plastic terminal boxes GHG 721... ATX type examination certificate BVS 13 ATX 013 X Marking acc. to 94/9/G and standard ATX x (d e mb) II T5* -55 T amb +55 Gb x (d e mb) II T6* -55
More informationBR 31a Rack-and-pinion Actuator,
Operating, assembly and maintenance instructions BR 31a Rack-and-pinion Actuator, SRP and DAP 1. General These instructions are intended to support the user in the assembly, maintenance, and repair of
More informationMaintenance Information
80234313 Edition 2 May 2014 Air Grinder, Die Grinder, Sander and Belt Sander Series G1 (Angle) Maintenance Information Save These Instructions Product Safety Information WARNING Failure to observe the
More informationAssembly and Operating Instructions
A35AE FU...A150AE FU en Assembly and Operating Instructions Plug-in drives Important information for: Fitters / Electricians / Users Please forward accordingly! These instructions must be kept safe for
More informationInstructions for Fitting, Operating and Maintenance Canopy Door RE / (St.: )
EN Instructions for Fitting, Operating and Maintenance Canopy Door 1 818 012 RE / (St.: 12.2010) 12.2010 ENGLISH Contents 1 Safety Instructions... 3 1.1 Qualified persons... 3 1.2 Symbols and signal words
More informationUser manual Patient chair Malin
User manual Patient chair Malin - Model 120-00103-00 Rock - Model 120-00103-01 Swing - Model 120-00103-02 Slim Behandlingsstol 120-00103-0n 2007-0013 issue 7 Tel +46-8- Table of content 1. Rini patient
More informationGLO-502/530 (RIM CLAMP TIRE CHANGER)
GLO-502/530 (RIM CLAMP TIRE CHANGER) OPERATION MANUAL DATE INSTALLED: SERIAL # MANUFACTURING DATE: (EAGLE - GLOBAL : NHT) TABLE OF CONTENT INTRODUCTION -------------------------------------------------------------------------------2
More informationSCAN OPTICS SO-161-R MICROSCOPE USER MANUAL
SCAN OPTICS SO-161-R MICROSCOPE USER MANUAL SO-161-R Ophthalmic Microscope User Manual Page 2 of 18 CONTENTS CONTENTS 2 LIST OF FIGURES 2 INTRODUCTION 3 INTRODUCTION 3 PARTS LIST 5 ASSEMBLY INSTRUCTIONS
More informationPower-edge. Pro. User manual. Power-edge Pro User Manual
Power-edge Pro User manual Power-edge Pro User Manual 1 Congratulations on your purchase of a Power-edge Pro ski edge sharpening machine! Your Power-edge Pro will allow you to grind regular or hardened
More informationInstructions for Use
Premium blade holder Instructions for Use Leica Premium blade holder Version 1.3, English 10/2012 Order number: 14 0491 82101, RevD Always keep this manual with the instrument. Read carefully before working
More informationPRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to
PRM-4 Phase Sequence and Motor Rotation Tester Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com PRM-4 Phase Sequence and Motor Rotation Tester English Users Manual
More informationPET UNIT DOSE CABINET
PET UNIT DOSE CABINET INSTALLATION MANUAL 244-200 244-205 FN: 08-134 Rev A 11/17 Pet Unit Dose Cabinet This manual covers operation procedures for the following products: 244-200 Cabinet, PET, Unit Dose
More informationMaintenance Information
04581245 Edition 2 May 2014 Air Grinder, Die Grinder and Sander Series G2 (Angle) Maintenance Information Save These Instructions Product Safety Information WARNING Failure to observe the following warnings,
More informationInstallation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.
Description Marking The ANTARES ExtSet makes it possible to distribute the Remote I/O ANTARES modules of an explosion-protected Remote I/O system ANTARES among a maximum of 4 metal mounting rails. For
More informationLifting device for standard removable versions
Operating manual Lifting device for standard removable versions Type 1889 haacon hilft heben haacon hebetechnik gmbh Josef-Haamann-Str. 6 D-97896 Freudenberg/Main Tel: +49 (0) 93 75/84-0 Fax: +49 (0) 93
More informationOperating Manual for sprayvalve MKDD-IS
Operating Manual for sprayvalve MKDD-IS Read this manual carefully before installing, operating or servicing this equipment. Keep always handy for further use. ALFRED SCHÜTZE Apparatebau GmbH - Spritztechnik
More informationOwner s (Operator s) Manual & Safety Instructions Manually Lever Operated Chain Hoist Model LX1B
Owner s (Operator s) Manual & Safety Instructions Manually Lever Operated Chain Hoist Model LX1B BULLETIN NO. LX-0804-CE-06 WARNING This equipment must not be installed, operated or maintained by any person
More informationUsers Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery
MS5900 Users Manual Table of Contents Introduction Motor and Phase Rotation Indicator is a handheld, battery-operated instrument designed to detect the rotary field of three-phase systems and determine
More informationBowl Feeder BF10 / BF15 Translation of operating and installation instructions
Bowl Feeder BF10 / BF15 Translation of operating and installation instructions Copyright by Afag GmbH This operation instruction applies to: Bowl feeder right 12 Bowl feeder left 12 Type Order number BF10
More informationOperating instructions. sonnenprotect for operators. KD-337 Part no Version X00.
Operating instructions for operators sonnenprotect 1300 KD-337 Part no. 22010 Version X00 info@sonnenbatterie.de www.sonnenbatterie.de EN IMPORTANT Read this documentation carefully before operation. Retain
More informationUser Manual SONESTA S2 & S3
User Manual SONESTA S2 & S3 Sonesta manufactures and sells tables and chairs for urology, gynecology, urodynamic diagnostics and upper GI procedures Copyright 2018 SONESTA MEDICAL AB. All rights reserved.
More informationInstruction manual. RP800 - HYDRAULIC actuator, load 150Kg. RP815 - LINAK actuator, load 150Kg
HYDRAULIC patient lift RP800 - HYDRAULIC actuator, load 150Kg MA RP800_805_806_ 807_810_811_815 02 A_12-2010 Electric patient lifts RP805 - LINAK actuator, load 150Kg RP806 - HIWIN actuator, load 150Kg
More informationOriginal Operating Manual
matev GmbH Nürnberger Str. 50 90579 Langenzenn T +49 (0) 9101 9087-0 F +49 (0) 9101 9087-20 info@matev.eu www.matev.eu Original Operating Manual Front Power System und Front PTO shaft FPS- JD X 950 R for
More informationGlobe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN
Globe Valve Type 3241 Fig. 1 Type 3241 Globe Valve Mounting and Operating Instructions EB 8015-1 EN Edition July 2012 Contents Contents Page 1 Design and principle of operation.................... 4 2
More informationDisc Brake System ( For Cross-Country)
Technical Service Instructions General Safety Information Disc Brake System ( For Cross-Country) SI-8C60F t WARNING Please use extra caution to keep your fingers away from the rotating disc brake rotor
More informationMICROFLOCKER. Operating Instructions
MICROFLOCKER Operating Instructions Campbell Coutts Ltd Unit 7 Tower Industrial Estate, Tower Lane Eastleigh SO50 6NZ, Hampshire, England sales@flocking.biz www.flocking.biz tel:+44(0) 23 80613700 fax:+44(0)
More informationIntroduction. The words WARNING, CAUTION and NOTE carry special meanings and should be carefully reviewed.
Operations/ Maintenance Manual Important Information File in your maintenance records Medical Visum Exam Light Model LL305 For parts or technical assistance call 800 327 0770 (option 2) Table of Contents
More informationType MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation
Handheld calibration tool / Handheld cleaning tool Tragbares Kalibrierwerkzeug / Tragbares Reinigungswerkzeug Outil d'étalonnage portatif / Outil de nettoyage portatif Operating Instructions Bedienungsanleitung
More informationPneumatic actuator Assembly & maintenance procedures
Pneumatic actuator Assembly & maintenance procedures SPRING RETURN ACTUATOR Fig.7901 DOUBLE ACTING ACTUATOR Fig.7902 - LCIE 05 AR 022 2 CONTENTS 1. Applicable Range... page 4-6 2. General Information...
More information