FYJR.EX Carbon Dioxide Extinguishing System Units, General Use. Carbon Dioxide Extinguishing System Units, General Use

Size: px
Start display at page:

Download "FYJR.EX Carbon Dioxide Extinguishing System Units, General Use. Carbon Dioxide Extinguishing System Units, General Use"

Transcription

1 Page 1 of 11 Page Bottom FYJR.EX1368 Carbon Dioxide Extinguishing System Units, General Use Carbon Dioxide Extinguishing System Units, General Use See General Information for Carbon Dioxide Extinguishing System Units, General Use CHEMETRON FIRE SYSTEMS 3RD FL 4801 SOUTHWICK DR MATTESON, IL USA EX1368 Low-pressure system units All storage tanks are manufactured and marked in accordance with ASME specifications having a rated working pressure of 350 psi. Models through or through /4 ton through or through ton, through or through /3/4 ton capacity, 42 in. ID storage units utilizing refrigerants R404A or R507. Models through ton, through ton, through or through ton, through ton capacity, 54 in. ID storage units utilizing refrigerants R404A or R507. Models through or through ton, through or through ton, through or through ton, through or through ton, through or through ton capacity, 78 in. ID storage units utilizing refrigerants R404A or R507. Storage Tanks Metal-housed and cork covered. All tanks provided with Listed refrigeration unit and controls and safety vent assembly. With or without integral transfer pump, Listed explosion-proof electrical equipment, cylinder filling connections, dual refrigeration. Models , , 3/8 and 1 ton units, respectively; Models through -0068, through -0102, through -0131, through -0137, through -0143, -0169, -0170, -0177, -0178, with suffix numbers related to capacities from 2 through 52 tons. Metal-housed with foamed polyurethane insulation. Models or /4 ton, or ton, or /4 ton, ton, ton, ton capacities, respectively. Fiberglass housing with foamed polyurethane insulation. Models , -0018, -0038, -0052, through with 17, 24, 31 and 13 ton capacities, respectively. Timers, Timer Valves Automatic mechanical timer, Discharge timer valve, C Selector valves. Size & Stock No. 1-1/2 in /4 8 13

2 Page 2 of /2 in /2 in /2 in / /2 in / /2 in /2 in / /2 in /2 in / /2 in /2 in /2 in Tank shut-off valves. 3 in , ,0998, in ,0999, in ,1000, in ,0997 Miscellaneous Equipment Manual Pilot Valve Station Stock No. Emergency manual release Flush Supervisory pressure switches , -178 Surface Three-way pressure operated valve Three-way pilot valves , -0801, Three-way solenoid valve B46621 Manual release station Electrical Components For Use with Low Pressure Systems Push-Button Stations Part Name Model No. First extended, surface 24308

3 Page 3 of 11 First extended, flush Second extended, surface Second extended, flush Spurt, surface Spurt, flush Control unit system, surface Control unit system, flush Pilot Control Valves Manual Pilot Valve Station Stock No. Electro-Manual Pilot Valve Cabinet D through -0439, D through Electrical 21443, Lever Operated Valves Size Stock No. With Limit Switch 3/4 in in /4 in /2 in in Use equivalent length for gate valve of appropriate size. The valves above have weather-resistant limit switches. Hand-Wheel Operated Valves Size Model No. 1 in , /4 in , /2 in in in in in Gate Valves 1-1/2 in

4 Page 4 of 11 2 in Note: Use equivalent length for gate valve of appropriate size. Ball valves. 1/4 in / / / / /4 in / / / / /4 in / / / / /4 in / / / / Butterfly valves 3 in in

5 Page 5 of 11 6 in High-pressure system units. Cylinder Valve Assemblies For use wth 50-, 75- or 100-lb. cylinders, classed DOT-3A, -3AA, or higher. Includes FC34937 valve, No flex- 1/ ible connector and one of the following discharge heads: FB34922, Includes FC34937 valve, No flex- 1/ ible connector and one of the following discharge heads: FB34922, Includes C50401 valve, No flex- 1/ ible connector and one of the following discharge heads: C50286 or B Size & Stock No. 1-1/2 in. - FD / /2 in. - FD /2 in. - FD / /2 in. - FD /2 in. - D /2 in. - D Release Equipment Pilot Oper Valve Model or Part No. Delayed discharge Immediate discharge FB34930 FB34931 Control Cabinets Multiple hazard D46070, D Manual release valve station B, Remote manual release station B41874 Miscellaneous Equipment Pressure release - 1/2 in. Pressure release - 1 in. FA21915 FA21932

6 Page 6 of 11 Safety relief, frangible disc type Connection kit A41597 A41892, A41893 Electrical Components - For Use With High Pressure Systems Push-Button Stations Pilot Oper Valve Model or Part No. Control unit system, surface , -2 Control unit system, flush , -2 System Units for High or Low Pressure Systems Control and Release Equipment Manual-pilot valve stations, surface Manual-pilot valve stations, flush Predischarge timer valve C41753 Discharge delay valve Pilot control valve Three-way pilot valve Three-way pilot valve, pressure operated C45982 B41783 C46316 Shuttle valve Switching valve Manual-pilot valve timer station, surface Manual-pilot valve timer station, flush Manual-pilot valve Door release FS Pressure-operated releases FA-21915, Pressure-operated pilot control valve Automatic mechanical discharge timer Automatic discharge delay timer Pneumatic release (rate of rise) FD C42129 C41588 C41582 Manual release valve station, push button operated B, Size & Part No. Check Valve 1/2 in. - C04BG02P-8 1/ /4 in. - C04BG02P-12 3/ /4 in. - C04BG02P /4 in. - C04BG02P /4 27

7 Page 7 of /2 in. - C04BG02P / /2 in. - C04BG02P (Check valves with suffix letters FF, FM, MF, or MM) B /2 11 B / / Size & Stock No. 1/2 in. - B , B / /4 in. - B , B / Electrical Components - For Use With High or Low Pressure System Units Push Button Station Model No. "On-Off", surface "On-Off", flush Momentary contacts, surface , -2 Momentary contacts, flush , -2 Pressure-operated switch Electrically operated solenoid valves: 115 v, 25 cy, ac A v, dc or 115 v, 60 cy, ac A v, dc A v, dc A v, dc A v, 50 Hz, ac A v, 60 Hz, ac, A v, dc 120 v, 50/60 Hz , Pressure Switches Hazardous locations, Class I, Groups C and D: Class II, Groups E, F and G. Part No. C42059 rated four pole, 30 amp, 250 v; Part No. C42068 rated two pole, 30 amp, 250 v. Part No. Blocking Valve Schedule 40 Schedule 80

8 Page 8 of / / / / Low-pressure system units. Storage Tanks All storage units provided with Listed refrigeration unit, controls, disconnect switch and safety vent assembly. Metal-housed with rigid isocyanurate cellular foam and pre-finished aluminum skin. Models , , , , , , , , , , , , , ; 3/4, 1-1/4, 1-1/4, 2, 2, 2-3/4, 2-3/4, 3-3/4, 4, 6, 6, 8, 10, 12 ton capacities respectively. Prefinished aluminum skin, rigid isocyanurate cellular foam with metal shrouding over refrigeration unit and controls. Models , -0003, -0004, -0005, -0007, -0008, -0009, -0010, -0011, -0012, -0013, ; 14, 18, 22, 26, 30, 34, 38, 42, 46, 50, 54, 58, 60 ton capacities respectively. Pilot Equipment Master Pilot Cabinet (Surface Mounted) V Part No. 120 v, ac - 60 Hz v, dc Selector Pilot Cabinet (Surface Mounted) 120 v, ac - 60 Hz v, dc Master Pilot Cabinet (Flush Mounted) 120 v, ac - 60 Hz v, dc Selector Pilot Cabinet (Flush Mounted) 120 v, ac - 60 Hz v, dc Hosereel Master Pilot Cabinet (Surface Mounted) 120 v, ac - 60 Hz v, dc Hosereel Selector Pilot Cabinet (Surface Mounted) 120 v, ac - 60 Hz v, dc Way Solenoid Valves 120 v, ac - 60 Hz

9 Page 9 of v, dc Electrical Components - For Use With Low Pressure Systems Part Name Part No. Push-button station; momentary contact, single light, 120 v, ac, dc v, dc v, dc Miscellaneous Equipment 1/4 in. Pressure regulator , /2 in. Pressure regulator , /2 in. Backflow check valve in. Check valve /2 in. Relief valve 350 PSI /2 in. Relief valve 250 PSI /2 in. Relief valve 275 PSI /2 in. Relief valve 375 PSI /2 in. Relief valve 450 PSI Manual Shut-Off Valves Model No. 1-1/2 in , / in , in , in , in , in , Master Valves 1/2 in , -0002, / /4 in , -0005, / in , -0008, /4 in , -0011,

10 Page 10 of / /2 in , -0014, / in , -0017, in , in , in , in , Selector Valves 1/2 in , -0002, / /4 in , -0005, / in , -0008, /4 in , -0011, / /2 in , -0014, / in , -0017, in , in , in , in , Last Updated on Questions? Notice of Disclaimer Page Top Copyright 2007 Underwriters Laboratories Inc. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright 2007 Underwriters Laboratories Inc. "

11 Page 11 of 11

January 2007 Approval Guide Fixed Extinguishing Systems 5-57

January 2007 Approval Guide Fixed Extinguishing Systems 5-57 Fixed Extinguishing Systems 5-57 CHEMETRON Fire Systems, 4801 Southwick Dr, 3rd Floor, Matteson IL 60443 High Pressure System Equipment. Automatic Actuator. 1-026-02, -0250. Alarm. 1-003-0033, -0070, -0071,

More information

JDDZ.E Cartridge Fuses, Nonrenewable. Cartridge Fuses, Nonrenewable

JDDZ.E Cartridge Fuses, Nonrenewable. Cartridge Fuses, Nonrenewable Seite 1 von 6 Page Bottom JDDZ.E258218 Cartridge Fuses, Nonrenewable Cartridge Fuses, Nonrenewable See General Information for Cartridge Fuses, Nonrenewable SIEMENS AG I BT LV POSTFACH 10 09 53 93009 REGENSBURG,

More information

JDYX2.E10480 Fuses, Supplemental - Component. Fuses, Supplemental - Component

JDYX2.E10480 Fuses, Supplemental - Component. Fuses, Supplemental - Component JDYX2.E10480 Fuses, Supplemental - Component Page Bottom Fuses, Supplemental - Component See General Information for Fuses, Supplemental - Component LITTELFUSE INC SUITE 500 8755 W HIGGINS RD CHICAGO,

More information

SUBMITTAL PACKAGE FIRE PROTECTION VALVES

SUBMITTAL PACKAGE FIRE PROTECTION VALVES SUBMITTAL PACKAGE FIRE PROTECTION VALVES Butterfly Valves Ductile Iron Grooved...pg 2-5 Grooved Check Valves...pg 6-8 OS&Y Valves...pg 9-12 ARGCO.com 800-854-1015 Updated 2/27/2017 ARGCO GROOVED BUTTERFLY

More information

UL Online Certifications Directory

UL Online Certifications Directory UL Online Certifications Directory BBCV2.MH12193 Lithium Batteries - Component Lithium Batteries - Component TADIRAN BATTERIES LTD 34 RABIN BLVD 76950 KIRYAT EKRON, ISRAEL MH12193 Model No. Primary Type

More information

WOYR2.E Switches, Special Use - Component. Switches, Special Use - Component

WOYR2.E Switches, Special Use - Component. Switches, Special Use - Component WOYR2.E98133 Switches, Special Use - Component Enhanced searching capability for this category can be found in UL's iq Family of Databases (www.ul.com/iq). Page Bottom Switches, Special Use - Component

More information

VNIV.EX454 Sprinklers, Automatic and Open. Sprinklers, Automatic and Open

VNIV.EX454 Sprinklers, Automatic and Open. Sprinklers, Automatic and Open VNIV.EX454 Sprinklers, Automatic and Open Page Bottom Sprinklers, Automatic and Open See General Information for Sprinklers, Automatic and Open RELIABLE AUTOMATIC SPRINKLER CO INC 1470 SMITH GROVE RD LIBERTY,

More information

GFGV.EX26590 Foam Liquid Concentrates. Foam Liquid Concentrates

GFGV.EX26590 Foam Liquid Concentrates. Foam Liquid Concentrates GFGV.EX26590 Foam Liquid Concentrates Page Bottom Foam Liquid Concentrates See General Information for Foam Liquid Concentrates FULLBLAZE LIMITED Oxford business Park North 7200 The Quorum Garsington Road

More information

QMFZ2.E Plastics - Component. Plastics - Component

QMFZ2.E Plastics - Component. Plastics - Component QMFZ2.E235269 Plastics - Component For enhanced search functionality, please visit UL's iq Family of Databases. Click on a product designation for complete information. Page Bottom Plastics - Component

More information

NMMS.E Power Conversion Equipment. Power Conversion Equipment

NMMS.E Power Conversion Equipment. Power Conversion Equipment 第 1 頁, 共 6 頁 Page Bottom NMMS.E177007 Power Conversion Equipment Power Conversion Equipment See General Information for Power Conversion Equipment TECO ELECTRIC & MACHINERY CO LTD 2ND FL 22 SEC 1 CHUNG-SHAN

More information

ARGONITE Fire Protection Systems

ARGONITE Fire Protection Systems GENERAL INFORMATION The Chemetron ARGONITE Fire Protection Systems are clean agent, automatic extinguishing systems using Argonite (IG55) and consisting of four basic components and their associated accessories.

More information

GFGV.EX6202 Foam Liquid Concentrates. Foam Liquid Concentrates

GFGV.EX6202 Foam Liquid Concentrates. Foam Liquid Concentrates GFGV.EX6202 Foam Liquid Concentrates Page Bottom Foam Liquid Concentrates See General Information for Foam Liquid Concentrates INTERNATIONAL SECURITY & SAFETY SYSTEMS CO S A E 49 ABBASS EL AKKAD ST NASR

More information

XGPU2.E Thermistor type Devices Component

XGPU2.E Thermistor type Devices Component XGPU2.E183209 Thermistor type Devices Component Page Bottom Thermistor type Devices Component See General Information for Thermistor type Devices Component LITTELFUSE INC SUITE 500 8755 W HIGGINS RD CHICAGO,

More information

東莞永力電業有限公司 YUNG LI CO., LTD. Da Pu Industrial Zone, Gang Zi, Changping Town, Dong Guan City, Guangdong China.P.R.C YP-12/YC-12 MAG CB-N-US-5M

東莞永力電業有限公司 YUNG LI CO., LTD. Da Pu Industrial Zone, Gang Zi, Changping Town, Dong Guan City, Guangdong China.P.R.C YP-12/YC-12 MAG CB-N-US-5M 東莞永力電業有限公司 YUNG LI CO., LTD Da Pu Industrial Zone, Gang Zi, Changping Town, Dong Guan City, Guangdong 523571 China.P.R.C TEL:0769-83396797~8 E-mail: sales@yung-li.com FAX:0769-83396796 Description: Customer:

More information

東莞永力電業有限公司 YUNG LI CO., LTD. Da Pu Industrial Zone, Gang Zi, Changping Town, Dong Guan City, Guangdong China.P.R.

東莞永力電業有限公司 YUNG LI CO., LTD. Da Pu Industrial Zone, Gang Zi, Changping Town, Dong Guan City, Guangdong China.P.R. 東莞永力電業有限公司 YUNG LI CO., LTD Da Pu Industrial Zone, Gang Zi, Changping Town, Dong Guan City, Guangdong 523571 China.P.R.C TEL:0769-83396797~8 E-mail: sales@yung-li.com FAX:0769-83396796 Description: Customer:

More information

東莞永力電業有限公司 YUNG LI CO., LTD. Da Pu Industrial Zone, Gang Zi, Changping Town, Dong Guan City, Guangdong China.P.R.

東莞永力電業有限公司 YUNG LI CO., LTD. Da Pu Industrial Zone, Gang Zi, Changping Town, Dong Guan City, Guangdong China.P.R. 東莞永力電業有限公司 YUNG LI CO., LTD Da Pu Industrial Zone, Gang Zi, Changping Town, Dong Guan City, Guangdong 523571 China.P.R.C TEL:0769-83396797~8 E-mail: sales@yung-li.com FAX:0769-83396796 Description: Customer:

More information

HPCO 2. Fire Extinguishing System

HPCO 2. Fire Extinguishing System HPCO 2 Fire Extinguishing System The Janus Fire Systems HPCO 2 Fire Extinguishing System utilizes highly pressurized carbon dioxide as the extinguishing medium. Carbon dioxide (CO 2 ) is a dry, inert,

More information

91 Series DataSheet KUOYUH. THERMAL OVERCURRENT CIRCUIT BREAKERS(PUSH-TO-RESET) ISSUE KUOYUH DATE CREATED 2007/7/16

91 Series DataSheet KUOYUH.   THERMAL OVERCURRENT CIRCUIT BREAKERS(PUSH-TO-RESET) ISSUE KUOYUH DATE CREATED 2007/7/16 www.kuoyuh.com 9 Series DataSheet THERMAL OVERCURRENT CIRCUIT BREAKERS(PUSH-TO-RESET) ISSUE DATE CREATED 007/7/6 AUTHOR Hunter Huang EDITION C W.L.Enterprise Co.,Ltd. 67.-6 HsiMei,TameiTusuen,Tsutang Hsiang,YunLin

More information

FIRE PROTECTION EQUIPMENT 2017 DATA SHEETS BSP FIRE RESERVES THE RIGHT TO ALTER INFORMATION CONTAINED IN THIS CATALOGUE AT ANY TIME.

FIRE PROTECTION EQUIPMENT 2017 DATA SHEETS BSP FIRE RESERVES THE RIGHT TO ALTER INFORMATION CONTAINED IN THIS CATALOGUE AT ANY TIME. FIRE PROTECTION EQUIPMENT 2017 DATA SHEETS BSP FIRE RESERVES THE RIGHT TO ALTER INFORMATION CONTAINED IN THIS CATALOGUE AT ANY TIME. DATA SHEET INDEX 36m x 19mm FIRE HOSE REEL RISER INSTALLATION DETAIL

More information

XGPU8.E Thermistor-type Devices Certified for Canada - Component. Thermistor-type Devices Certified for Canada - Component

XGPU8.E Thermistor-type Devices Certified for Canada - Component. Thermistor-type Devices Certified for Canada - Component Page 1 of 10 Page Bottom XGPU8.E305051 Thermistor-type Devices Certified for Canada - Component Thermistor-type Devices Certified for Canada - Component See General Information for Thermistor-type Devices

More information

Custom Shipyard and Military Facility Products

Custom Shipyard and Military Facility Products Custom Shipyard and Military Facility Products Safety Products Designed for Special Applications Respiratory Protection, Confined Space Ventilation and Portable Area Lighting Off the Shelf Or Custom Solutions

More information

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung

VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung VDE Prüf- und Zertifizierungsinstitut Zeichengenehmigung Ausweis-Nr. / Certificate No. 120831 Blatt / Page 2 Name und Sitz des Genehmigungs-Inhabers / Name and registered seat of the Certificate holder

More information

NMMS.E Power Conversion Equipment. Power Conversion Equipment

NMMS.E Power Conversion Equipment. Power Conversion Equipment Page 1 of 5 Page Bottom NMMS.E176972 Power Conversion Equipment Power Conversion Equipment See General Information for Power Conversion Equipment DELTA ELECTRONICS INC 31-1 SHIEN PAN RD KUEI SAN INDUSTRIAL

More information

ADVANCED CUSTOMIZED ELECTRO PNEUMATIC TRAINER (PRODUCT CODE: SAP 20B)

ADVANCED CUSTOMIZED ELECTRO PNEUMATIC TRAINER (PRODUCT CODE: SAP 20B) The Advanced Customized Electro Pneumatic Trainer (SAP 20B) is capable of being used to demonstrate the design, construction and application of electro-pneumatic components and circuits. Objectives:- The

More information

Technical Data Sheet SEVO 1230 Clean Agent Cylinders

Technical Data Sheet SEVO 1230 Clean Agent Cylinders SEVO 1230 Clean Agent Cylinders 140057, 140069, 140079, 140107, 14817, 14813 U lizing 3M TM Novec TM 1230 Fire Protec on Fluid The agent storage cylinder is a steel pressure vessel manufactured, tested

More information

Consider The Possibilities...

Consider The Possibilities... FS/FD Air-Cooled Fluid Cooler Catalog 710.1 Consider The Possibilities... Cools most any non-corrosive fluid Closed-circuit cooling avoids contamination Cold weather economizer for interior cooling loads

More information

HEAD VALVE. Model No.: NF 40/600V, NF 40/360V DESCRIPTION

HEAD VALVE. Model No.: NF 40/600V, NF 40/360V DESCRIPTION HEAD VALVE Model No.: NF 40/600V, NF 40/360V DESCRIPTION NAFFCO 40/600 & NAFFCO 40/360 valve is a quick opening differential valve, especially designed for gaseous extinguishing agents in modular/centralized

More information

LPCO 2 System. Refrigerated Storage Units FEATURES

LPCO 2 System. Refrigerated Storage Units FEATURES LPCO 2 System Refrigerated Storage Units Janus Fire Systems Low Pressure Carbon Dioxide Refrigerated Storage Units are specifically designed to store the carbon dioxide agent supply utilized in the Janus

More information

Section R Foam Systems

Section R Foam Systems Section R TABLE OF CONTENTS... R-1 R-3 Concentrate Control Valves and Trim... R-4 Valve Trim for Premixed... R-4 Release Trim Packages... R-4 Foam Concentrates... R-5 Accessories, Foam Concentrates...

More information

Section R Foam Systems

Section R Foam Systems Section R TABLE OF CONTENTS... R-1 R-3 Concentrate Control Valves and Trim... R-4 Valve Trim for Premixed... R-4 Release Trim Packages... R-4 Foam Concentrates... R-5 Accessories, Foam Concentrates...

More information

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION. A. Pipe, fittings, valves, and connections for sprinkler systems.

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION. A. Pipe, fittings, valves, and connections for sprinkler systems. SECTION 210500 - COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, valves, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS A. Section 099000

More information

earth safe Fuel Systems for Critical Power

earth safe Fuel Systems for Critical Power Fuel System Control Valves 100 Solenoid Valves 110 Solenoid Valve Slow Close 120 Actuated Ball Valves 123 Actuated Ball Valves 3-Way 130 Actuated Butterfly Valves 140 Fire Safety Fusible Link Valves 145

More information

Full-featured operator with slim profile for moderate to high traffic applications LOW ENERGY OPERATOR CATALOG

Full-featured operator with slim profile for moderate to high traffic applications LOW ENERGY OPERATOR CATALOG Full-featured operator with slim profile for moderate to high traffic applications 6300 S E R I E S LOW ENERGY OPERATOR CATALOG INTRODUCTION The Norton 6300 Series Low Energy Operator offers a broad set

More information

FM FIRE-SAFE VALVE ASSEMBLIES & ACTUATORS. Meets API 607 Edition 3 and 4, Factory Mutual FM 7440

FM FIRE-SAFE VALVE ASSEMBLIES & ACTUATORS. Meets API 607 Edition 3 and 4, Factory Mutual FM 7440 FM FIRE-SAFE VALVE ASSEMBLIES & 90 ACTUATORS "F" "G" Meets API 607 Edition 3 and 4, Factory Mutual FM 7440 "F" "G" Assured Automation 19 Walnut Avenue Clark, NJ 07066 Tel: 800-899-0553 assuredautomation.com

More information

Alpha Series Systems

Alpha Series Systems GENERL INFORMTION LPH SERIES SYSTEM EQUIPMENT DESCRIPTION The Chemetron Fire Systems are automatic suppression systems using the FM-200 chemical agent and consisting of four basic components and their

More information

Wet pipe low flow foam/water manifold system

Wet pipe low flow foam/water manifold system December 6, 2010 Foam 15a 1. Description With the Wet Pipe Low Flow Foam/Water Manifold System, multiple risers can be supplied from a single proportioning device. A riser manifold is installed with various

More information

Model 5000 Level Controller

Model 5000 Level Controller Features Multiple Configurations The 5000 level controller is easily configured for either reverse or direct actions for both pneumatic and electric pilot options. The pneumatic pilot is available in snap

More information

Alpha Series Systems

Alpha Series Systems GENERL INFORMTION LPH SERIES SYSTEM EQUIPMENT DESCRIPTION The Chemetron Fire Systems are automatic suppression systems using the FM-200 chemical agent and consisting of four basic components and their

More information

Features 1. Differential Latch-type, lightweight, dependable

Features 1. Differential Latch-type, lightweight, dependable Bulletin 516 Rev. B Model DDX-SS Deluge Valve (100mm), (150mm) & (200mm) Bulletin 516 Rev. B Features 1. Differential Latch-type, lightweight, dependable construction. 2. Easily trimmed for releasing by:

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL HP COMBINATION GAS/OIL BURNERS THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone 316-421-0480, Fax 316-421-0948

More information

Cascade Master Series

Cascade Master Series Overview The Cascade Master Series option consists of five components, which control standard chair and delivery system functions. These components include: master touchpad, master 17-watt power supply,

More information

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT R4A4 Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors

More information

Air-Cooled Fluid Cooler

Air-Cooled Fluid Cooler Catalog KM-FSD-0313A FS/ FD Series Air-Cooled Fluid Cooler Consider The Possibilities Cools most any non-corrosive fl uid Closed-circuit cooling avoids contamination Cold weather economizer for interior

More information

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual Manual No. 5AOP-OM1-2 Val-Matic Air / Oil Hydraulic Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION...

More information

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER ENVIRONMENTALLY SOUND REFRIGERANT HCA7 QuietComfort DXT+ Product Specifications HIGH EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230

More information

THE DEFENDER 4D-200 SERIES

THE DEFENDER 4D-200 SERIES THE DEFENDER 4D-200 SERIES SPECIFICATIONS The Reduced Pressure Principle Assembly shall protect against backflow by either backpressure or back-siphonage from a crossconnection between potable water system

More information

Sigma Series Systems

Sigma Series Systems GENERL INFORMTION The Chemetron Fire Systems are automatic suppression systems using the FM-200 chemical agent and consisting of four basic components and their associated accessories. FM-200 Components

More information

Model DDX Deluge Valves 4" (100 mm), 6" (150 mm) and 165 mm Sizes

Model DDX Deluge Valves 4 (100 mm), 6 (150 mm) and 165 mm Sizes Features 1. Differential-type, lightweight, dependable construction. 2. Easily trimmed for releasing by: Manual pull stations Wet pilot sprinklers Dry pilot actuators Solenoid valves 3. Drop in seat &

More information

O IL & G AS INDUSTRIAL VALVES, ACTUATORS & ACCESORIES

O IL & G AS INDUSTRIAL VALVES, ACTUATORS & ACCESORIES O IL & G AS O IL & G AS License Number 6D-1724 FORGED STEEL Size Range Ball Valves API 6D / BS EN ISO 17292 Gate Valves Globe Valves API 602 / BS EN ISO 15761 Class 150-2500 / Class 800 ½ - 2 Check Valves

More information

Series CC Condensate Units

Series CC Condensate Units Bulletin S-215F Series CC Condensate Units Simplex or Duplex 1,000 thru 15,000 sq. ft. EDR 250 thru 7,500 lb./hr. Cast Iron Receivers: for years of dependable service; warranted for 20 years from date

More information

Actuated Valves PRICING

Actuated Valves PRICING Electric & Pneumatic Actuated Valves Actuated Valves PRICING Page Suitable for Oil-Free air handling to 5 psi, not for distribution of compressed air or gas Spears Manufacturing Company Due to Material

More information

Proportional Pressure Reducing Valve PDM08130

Proportional Pressure Reducing Valve PDM08130 Proportional Pressure Reducing Valve PDM08130 up to 80 bar up to 10 l/min Cartridge valves Control electronics Connection housings 486 1. DESCRIPTION 1.1. GENERAL According to DIN-ISO 1219, HYDAC proportional

More information

Size: 1/4 to 3. Material: 316 Stainless Steel, Carbon Steel,

Size: 1/4 to 3. Material: 316 Stainless Steel, Carbon Steel, Size: 1/4 to 4 Material: 316 Stainless Steel, Carbon Steel, Alloy 20, Hastelloy C, Monel, Brass, SW, BW, BSPT, 150#, 300#, 600#, Flanged Pressure: Vacuum to 3000 PSI* -50 to 600 F* ASME B16.34 Design Bottom

More information

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date MEA: 248-98-E CSFM: 7770-0531-117 The patent-pending Victaulic Series 769 FireLock NXT controls the water supply entry into the deluge system piping and open sprinklers. The Series 769 is a low differential,

More information

Solumatics Engineering (M) Sdn. Bhd. Water Solenoid Valve. Steam Solenoid Valve. 1 of 32

Solumatics Engineering (M) Sdn. Bhd. Water Solenoid Valve. Steam Solenoid Valve. 1 of 32 Solumatics Engineering (M) Sdn. Bhd. Water Solenoid Valve Steam Solenoid Valve 1 of 32 Stainless Steel Solenoid Valve Stainless Steel Flange End Solenoid Valve 2 of 32 Solenoid Pilot Operated Valve For

More information

Model DDX Deluge Valve 8 (200mm) Features

Model DDX Deluge Valve 8 (200mm) Features Model DDX Deluge Valve 8 (200mm) Bulletin 514 Bulletin 514 Features 1. Differential Latch-type, lightweight, dependable construction. 2. Easily trimmed for releasing by: Manual pull stations Wet pilot

More information

Valves and Valve Assemblies

Valves and Valve Assemblies Valves and Valve A-T Controls, Inc. Valves and valve assemblies for liquid and gas shut-off These assemblies are FM approved for use in applications requiring protection for fuel burning equipment per

More information

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA ENGINEERING DATA ENGINEERING DATA MATCHED REMOTE SYSTEMS 50hz HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw (60 200 to 222 500 Btuh) HS17 Bulletin #490001 November 1995 Supersedes August 1994 HS17-1353

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE March 21, 2008 Foam 180a 1. DESCRIPTION The Viking bladder tank consists of an inner tank (bladder) fabricated of a flexible material (Buna-N over nylon) and an outer tank fabricated from carbon steel.

More information

PIPING TO HAZARD PIPING TO HAZARD AGENT SOURCE AGENT SOURCE TOP VIEW TOP VIEW

PIPING TO HAZARD PIPING TO HAZARD AGENT SOURCE AGENT SOURCE TOP VIEW TOP VIEW Kidde Engineered Fire uppression ystem Designed for use with 3M Novec 1230 Fire Protection Fluid 3-Way Directional Ball Valve Data heet Effective:March 2005 K-45-9070 FEATURE For use with Kidde Engineered

More information

HORIZONTAL BLADDER TANKS

HORIZONTAL BLADDER TANKS HORIZONTAL BLADDER TANKS The Chemguard Horizontal Bladder Tank is one component in a balanced pressure foam proportioning system. It requires no external power, other than the water pressure to ensure

More information

April 2004 / BULLETIN for Supermarket Systems DDR-20 OLDR-15

April 2004 / BULLETIN for Supermarket Systems DDR-20 OLDR-15 April 2004 / BULLETIN 90-50 for Supermarket Systems DDR-20 OLDR-15 Page 2 / Bulletin 90-50 SPORLAN DEFROST DIFFERENTIAL PRESSURE REGULATING VALVES OFFER THESE BENEFITS: Able to maintain a differential

More information

MODEL 10LH SPECIFICATION

MODEL 10LH SPECIFICATION MODEL 10LH SPECIFICATION 1.0 General Specifications There will be furnished one (1) only Grind Hog TM Model 10LH Comminutor as manufactured by G.E.T. Industries, Inc. Rotation shall be in a clockwise (standard)

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power 4.55 Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /4" to " NT / 3/ 4/ 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 low wattage coil Standard ambient

More information

Mounted Instrument Head

Mounted Instrument Head INSTALLATION INSTRUCTIONS for the Asepsis 21 Cabinet TM Mounted Instrument Head SECTION I - REQUIREMENTS 1. PHYSICAL REQUIREMENTS... 1 4. WATER SUPPLY REQUIREMENTS... 1 5. AIR SUPPLY REQUIREMENTS... 1

More information

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance Bulletin 59 Model DDX Deluge Valve (50 mm), ½ (65 mm), (80 mm), 76 mm, 4 (00 mm), 6 (50 mm), 65 mm & 8 (00 mm) Bulletin 59 Instructions for Installation, Operation, Care and Maintenance Wet Pilot Line,

More information

Protection Systems. 3-Way Directional Valve P/N: XX-00X. A UTC Fire & Security Company FEATURES

Protection Systems. 3-Way Directional Valve P/N: XX-00X. A UTC Fire & Security Company FEATURES Effective: Nov. 2010 Fenwal Phoenix Directional Valve P/N: 93-2200XX-00X TM R Protection ystems A UTC Fire & ecurity Company F-93-121 FEATURE For use with Fenwal Phoenix ystems Cost-Effective Option for

More information

MARINE HIGH PRESSURE CARBON DIOXIDE SYSTEMS Component Sheet Library

MARINE HIGH PRESSURE CARBON DIOXIDE SYSTEMS Component Sheet Library MARINE HIGH PRESSURE CARBON DIOXIDE SYSTEMS Component Sheet Library One Stanton Street / Marinette, WI 54143-2542, USA / +1-715-735-7411 / www.ansul.com Copyright 2015Tyco Fire Products LP. / All rights

More information

Hazardous Duty Applications

Hazardous Duty Applications Hazardous Location Hazardous Duty Plugs, Receptacles and Interlocks Hazardous Duty Plugs, Receptacles and Interlocks Hazardous Duty Applications Russellstoll Hazardous Duty Plugs, Receptacles and Interlocks

More information

H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND REFRIGERANT EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Copeland

More information

Stainless Steel The Next Generation of Backflow

Stainless Steel The Next Generation of Backflow Stainless Steel The Next Generation of Backflow Zurn Wilkins Stainless Steel Backflow Preventer Superior Quality, Technologically dvanced 3L grade stainless steel body available in grooved or flanged end

More information

EMIP60 ISO. EM Series, Inch Pounds - 60 Hz EM (iso) Spec Guides Drawings Spec Sheets Extended Range Ratings Low Temp Heating.

EMIP60 ISO. EM Series, Inch Pounds - 60 Hz EM (iso) Spec Guides Drawings Spec Sheets Extended Range Ratings Low Temp Heating. EMIP60 ISO EM Series, Inch Pounds 60 Hz EM007360 (iso) Spec Guides Drawings Spec Sheets Extended Range Ratings Low Temp Heating Rev 1003 Revisions: 81402 Changed EM170/240HZ dwg 31103 Changed HZ dwg to

More information

EFC. Electronically Adjustable Proportional Pressure Compensated Flow Control

EFC. Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. 3000 psi (207 bar) rating. Weighs 8-1/2 lbs. (3.9 kg). Standard Port size #12SAE (1-1/16 12). 10-Micron Filtration Recommended.

More information

BS 2,7-6,7. Steel Containers with Differential Pressure Valve for the CLEAN AGENT FS 49 C2 Extinguishing Agent. Optional

BS 2,7-6,7. Steel Containers with Differential Pressure Valve for the CLEAN AGENT FS 49 C2 Extinguishing Agent. Optional BS 2,7-6,7 Steel Containers with Differential Pressure Valve for the CLEAN AGENT FS 49 C2 Extinguishing Agent FEATURES All components comply fully with international regulations for land and marine use.

More information

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,

More information

Scotch-Yoke LEDEEN Actuators. Gas-over-oil and direct-gas actuators

Scotch-Yoke LEDEEN Actuators. Gas-over-oil and direct-gas actuators Scotch-Yoke LEDEEN Actuators Gas-over-oil and direct-gas actuators Scotch-Yoke Gas-Over-Oil LEDEEN Actuators Typical application For on-off control of any natural gas transmission ball or plug valve utilizing

More information

Port Flow Rate/ Function Series Actuators Page Number Size Factor

Port Flow Rate/ Function Series Actuators Page Number Size Factor Section dex Port Flow Rate/ Function Series Actuators Page Number Size Factor 0- Cv = 0.05 Way Modular Solenoid. -. & to Way Manifold /8 NPT Cv = 0. Way, Position Modular /8 NPT Cv = 0.05 Way Hex Solenoid.5.6

More information

User's Manual. Earth Ground Resistance Tester. Model Introduction

User's Manual. Earth Ground Resistance Tester. Model Introduction User's Manual Earth Ground Resistance Tester Model 382152 Introduction Congratulations on your purchase of the Extech Earth Ground Resistance Tester. This device can measure resistance (in 3 ranges) and

More information

Series 769 FireLock NXT Deluge Valve

Series 769 FireLock NXT Deluge Valve IPS CARBON STEEL PIPE FIRE PROTECTION PRODUCTS Series 79 FireLock NXT Deluge Valve With Deluge Trim Grooved X Grooved 30.81 VICTAULIC IS AN ISO 9001 CERTIFIED COMPANY PRODUCT DESCRIPTION The patent-pending

More information

AC Motor Brakes. General Information. Features. Add-On Brakes. Spring Applied Power-Off Operation. Motor Brake Coil Current. Mounting.

AC Motor Brakes. General Information. Features. Add-On Brakes. Spring Applied Power-Off Operation. Motor Brake Coil Current. Mounting. Spring Applied Power-Off Operation Power-Off Operation Inertia Dynamics AC-style, spring applied motor brakes are designed to decelerate or park inertial loads when the voltage is turned off, either intentionally

More information

SUSSMAN 'ES, HU and MBA' SERIES PARTS LIST EFFECTIVE: 7/24/2017

SUSSMAN 'ES, HU and MBA' SERIES PARTS LIST EFFECTIVE: 7/24/2017 EFFECTIVE: 7/24/2017 STEAM SAFETY VALVES 99136 100 PSIG 1/2" NPT (ES12 to ES72) 99137 100 PSIG 1" NPT (ES84 to ES180) 99132 15 PSIG 1/2" NPT (ES12 to ES48, HU40 to HU140) 99297V 15 PSIG 3/4" NPT (ES60

More information

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers

More information

MARINE INERGEN 150-BAR SYSTEMS Component Sheet Library

MARINE INERGEN 150-BAR SYSTEMS Component Sheet Library MARINE INERGEN 150-BAR SYSTEMS Component Sheet Library One Stanton Street / Marinette, WI 54143-2542, USA / +1-715-735-7411 / www.ansul.com Copyright 2015 Tyco Fire Products LP. / All rights reserved.

More information

Safety Considerations

Safety Considerations Safety Considerations The following safety rules MUST BE FOLLOWED to ensure safety in the laboratory. General Considerations No smoking, eating or drinking in the laboratory. Hydraulic oil in its vapor

More information

S v S e r i e s F M f i r e e x t i n g u i s h i n g s y s t e m

S v S e r i e s F M f i r e e x t i n g u i s h i n g s y s t e m Clean S v S e r i e s F M - 2 0 0 f i r e e x t i n g u i s h i n g s y s t e m Advantages The Sv Series Clean Agent Fire Extinguishing System utilizes FM-200 as the extinguishing medium. FM-200 is a colorless,

More information

Millennium TM. 100 thru 675 Tons (315 thru 2375 kw) renewal parts. Supersedes: RP1 (1099) Form RP1 (710) R-22 and R-134a 00202VIP

Millennium TM. 100 thru 675 Tons (315 thru 2375 kw) renewal parts. Supersedes: RP1 (1099) Form RP1 (710) R-22 and R-134a 00202VIP Millennium TM Rotary Screw Liquid Chillers renewal parts Supersedes: 160.80-RP1 (1099) Form 160.80-RP1 (710) Model YS BA CB S0 thru YS FA FB S5 (Style E) 100 thru 675 Tons (315 thru 2375 kw) 00202VIP R-22

More information

3/8 & 1/2 NPT. 4-Way - 5 Ported - 2 Position - Type 2 Use on all 4 Way - 2 Position applications

3/8 & 1/2 NPT. 4-Way - 5 Ported - 2 Position - Type 2 Use on all 4 Way - 2 Position applications 8 SERIES: /8 Ported Air Valves, A & B SERIES: / Ported Air Valves /8 & /, A, B & 8 Series, & Way; & Position Operation to 50 psi Note! Spring return & spring centered models NOT suitable for dry air service.

More information

HS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA

HS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA ENGINEERING DATA ENGINEERING DATA MATCHED CONDENSING REMOTE SYSTEMS UNITS 50hz HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM 3.6 to 16.0 kw (12 200 to 54 700 Btuh) HS18 Bulletin

More information

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan. 57 574 4 574 573 57 57 57 57 1 571 47 474 4 474 473 47 47 47 47 1 471 56 567 7 565 565 37 374 74 374 7 373 37 37 37 37 1 371 467 6 467 465 465 7 74 4 74 73 7 7 7 7 7 71 71 36 367 7 365 365 6 67 7 65 65

More information

1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS Publication No. WT-WFH-1115B W-Series Next-Gen Proline 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS 2 W-Series The Next Generation of Prolines are Here! Witt s Next-Gen Proline W-Series ½

More information

GLOBAL DRILLING SOLUTIONS, INC STOCK LIST

GLOBAL DRILLING SOLUTIONS, INC STOCK LIST GLOBAL DRILLING SOLUTIONS, INC STOCK LIST Item Description Qty in Stock Lighting Equipment LED Flood Light. IECEX Certificed. Explosion proof / Zone & ; Ex d IIB T Gb; IP. / Rated voltage: 00 00VAC, 0/0Hz.

More information

Protection Systems. 3-Way Directional Ball Valve P/Ns: X and X. A UTC Fire & Security Company FEATURES

Protection Systems. 3-Way Directional Ball Valve P/Ns: X and X. A UTC Fire & Security Company FEATURES Effective: April 2007 Fenwal Phoenix 3-Way Directional Ball Valve P/Ns: 93-118325-00X and 93-118327-00X TM R Protection ystems A UTC Fire & ecurity Company F-93-120 FEATURE For use with Fenwal Phoenix

More information

Mini 1. Compact High Flow 3-Way and 4-Way Pneumatic Directional Control Valves

Mini 1. Compact High Flow 3-Way and 4-Way Pneumatic Directional Control Valves Catalog LX-530 Mini 1 Compact High Flow and Pneumatic Directional Control Valves FEATURES: 3-port or 5-port bodies Manual, Air Pilot, Solenoid or Mechanical Operators Two-position, Single or Dual Actuation

More information

MC2500. Installation and Operation Manual

MC2500. Installation and Operation Manual MC2500 Installation and Operation Manual Important: This manual contains specific cautionary statements relative to worker safety. Read this manual thoroughly and follow as directed. It is impossible to

More information

NXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER

NXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND REFRIGERANT NXA6 Performance Series Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt,

More information

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure

More information

Integrated Control modules

Integrated Control modules .60.0 Rev. 0 Page of 9 Integrated Control modules QC, QC2 and QC Features: - Basic actuator functions for: - Spring return applications, or - Double acting applications or, - Double acting Fail in Last

More information

Comfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities

Comfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities 3-35 kw 10,200-119,420 Btuh 208 to 600 Volts 1 or 3 Phase Meets NEC, OSHA and UL Requirements ATEX and GOST Models Available Refer to WR-80EP in the Controls section. F-4 Description Type is designed to

More information

Woodhouse International LLC P.O.Box 23724, Dubai, UAE Tel , Fax

Woodhouse International LLC P.O.Box 23724, Dubai, UAE Tel , Fax 001-0140 Valve, Bag & Gas Assy For S&S/ 5 Gal. Ea 1 010-5100 Valve, 4 Way, Koomy Spare Ea 2 041-3100 Gauge, Receiver 4-1/2" Face, 0-3000 psi Ea 2 1000-3109 Spacer, 601-1318 5 1000-4195 Kit, Port Assy,

More information

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY TYPE AEHE, AEHH8N, AEHH8NCF, AEUH8NDC Effective 05-01-13 Supercedes 08-01-11 APPLICATIONS: Fans & Blowers Compressor Any Severe Duty/ Petro-Chem/ Pumps Mixers Pulp

More information