Manual. Master Acid Injection System. Installation Maintenance Repair Manual. Model DEMA Ag 0960-A
|
|
- Griselda Tracey Curtis
- 5 years ago
- Views:
Transcription
1 Manual Master Acid Injection System Model DEMA Ag 0960-A Installation Maintenance Repair Manual 11/2013 1
2 DEMA Ag pump Instruction & Maintenance Manual Table of Contents Contents Page I. Introduction...3 II. Unpacking...4 III. Safety Considerations...4 IV. Installation...4 A. Mounting...4 B. Electrode Installation...5 C. Electrical...5 D. Chemical Injection Plumbing...6 V. Start-Up...8 A. Front Panel Description...8 B. Run Mode Explanation...8 C. Set-Up Mode Explanation...9 D. Priming the Pump...9 E. Stroking Speed or Frequency...9 F. Stroke Length...9 G. Calculating Output...10 H. Calibration...10 VI. Control Options VII. Menu Maps...12 VIII. Maintenance...13 A. Diaphragm Replacement...13 B. Suction and Discharge Check Valve Replacement...13 C. Cleaning Probe...13 D. Liquid End Diagram...15 E. Pump Replacement Parts...15 IX. Diagrams...16 X. Trouble Shooting Guide
3 I. Introduction This manual covers all facets of operation of the DEMA Ag pump, including unpacking, mounting, electrical and plumbing connection, and start-up. Safety, maintenance and repair, warranty, and factory information is also provided. Please read this manual completely before proceeding. Observe safety protocols and heed all warnings and precautions. 3
4 II. Unpacking DEMA Ag series pumps are shipped as a complete package, ready for installation. If the shipping carton shows any signs of damage, notify the shipping company immediately upon receipt. DEMA cannot be held responsible for damage from shipping. Unpack the carton and insure the following items are present: 1. Pump/controller 7. Injection fitting 2. Suction, discharge and bleed tubing 8. Instruction manual 3. Foot valve and weight 4. Probe and tee assembly 5. 2 two wire cables for possible connection to flow switch or flow meter 6. A green solution reference wire to connect to the probe III. NOTE: Safety Considerations All DEMA Ag pumps are primed with water before leaving the factory. If the solution to be pumped is not compatible with water, disassemble the pump fluid end before use. After disassembly, thoroughly dry the pump head, valves, and seals before pump is reassembled and used. A. Chemical Compatibility DEMA Ag metering pumps are designed to work with most liquid chemicals depending upon your pump s liquid end materials of construction. A chemical resistance chart is available for determining specific compatibility with a wide variety of chemicals. B. Safety and Preparation Always wear the proper protective clothing and gear when working around chemicals and chemical metering pumps. Safety glasses, gloves, and aprons are critical in preventing accidental exposure to dangerous chemicals. Liquids under pressure can present a special hazard when a line or seal is punctured resulting in the spraying of chemical many yards away. If a chemical spillage occurs, consult the Material Safety Data Sheet (MSDS) for specific instructions regarding the chemical being used. IV. Installation A. Mounting The standard DEMA Ag series pump is prewired for easy installation. Select a secure mounting location convenient to electrical and plumbing connections that is accessible by the operator. Do not install the pump in a location where the ambient temperature exceeds 120 F (50 C). The pump is suitable for most outdoor installations, shielding from direct exposure to the elements is recommended. The properties of solutions to be metered should also be considered concerning temperature changes and effects to poly tubing. Accessory item R00225 (plastic mounting bracket) is recommended for a secure installation. 4
5 B. Electrode Installation The standard DEMA Ag series pump is provided with a TPE-21 quick disconnect probe and tee assembly on an 10 lead. The tee has ¾ female slip connections. The probe must be installed vertical to the piping in a sample line having an inlet pressure higher than the outlet and 3-10 gpm flow for proper operation. Isolation valves on both sides of the probe assembly are needed to allow for easy removal of the probe for cleaning. See page 17 for probe and optional flow switch assembly diagrams. NOTE: Chemical injection is typically upstream from the probe! C. Electrical 1. The Standard DEMA Ag pump has a voltage regulated internal power supply capable of operating in the range of approximately 95 to 135 VAC. Use a supply voltage of 100 to 120 VAC for best results. The 3-wire grounded plug must be used in a 3-wire wall plug. 2. With a 240 volt option, the DEMA Ag pump has a voltage regulated internal power supply capable of operating in the range of approximately 195 to 260 VAC. Use a supply voltage of 210 to 250 VAC for best results. Pump is supplied without a country specific plug unless otherwise specified. CAUTION: Never remove ground wire from plug! 3. Control relay output voltage is equal to incoming line voltage with a 5 amp fuse. Notes: 1. An isolated circuit breaker with a true earth ground is highly recommended to insure uninterrupeted operation. 2. Low voltage signal wire (water meter signal or probe wire) should never be run in conduit with high voltage wire above 30 VAC. Water Meter Injection Point ph Probe must be pointed down * Distance between injection point and ph probe must be a minimum of 10 feet, unless sent through a mixing process. ** Maximum probe wire run without signal booster is 20 feet. 5
6 D. Chemical Injection Plumbing 1. Piping Connections The DEMA Ag pump uses carefully matched components to achieve a predictable metering output. This predictability can only be maintained if all fitting sizes remain unaltered. Do not attempt to reduce tubing size. All tubing connections should be double checked to insure against leakage. If hazardous chemicals are being pumped, use shielding around discharge tubing. NOTE: When cutting lengths of tubing for your installation, ensure a clean, square cut. Use short lengths of tubing and as few connections as possible. 2. Tubing Nuts Do not overtighten the tubing connectors. Tighten the fittings no more than 1/4 turn after the fitting contacts the seal. Hand tighten only. Do not use a wrench or pliers as they may damage the fittings. Do not use Teflon tape except on NPT fittings. Be sure to observe applicable local plumbing codes. WARNING: Clear flexible tubing is not intended for pressurized use. 3. Tubing Connections 3/8" TUBING MUST SLIP OVER NIPPLE 4. Suction Lift vs Flooded Suction Applications Suction Lift Installation Mount the DEMA Ag pump around the top of the solution tank, not to exceed 5 feet from pump to bottom of tank. Flooded Suction This installation is recommended for very low outputs, solutions that gasify and/or high viscosity solutions. Priming is easier and loss of prime is reduced. Failure of the pump diaphragm or rupture of the solution tubing can cause loss of solution in the tank. 6
7 Suction lift Flooded Suction Not recommended 5. Foot valve installation A weight is provided to hold the tubing and foot valve in a vertical position at the bottom of the tank. Do not allow the foot valve to lay horizontally in the chemical container. This defeats the action of the valve and causes the pump to lose prime. Keep suction tubing reasonably short and avoid high spots or bends. 6. Injection valve installation The injection valve is designed to prevent a back flow and to inject chemical into the line. To work properly, this valve must be mounted within 45 degrees of vertical (see drawing). One end of the injection valve is 1/2 MNPT. Install this end into the piping system. Use Teflon tape on this fitting only. Connect the pump s discharge tubing to the opposite end of the injector. Do not use Teflon tape or joint compound on this fitting. Connect tubing between this fitting and the pump discharge fitting at the pump head. USE Teflon Tape On These Threads Only Pipe Cross Section DO NOT Use Teflon Tape On Machine Threads NOTE: Flow 80 Variation Acceptable Injection Check Valve When installation is made into a line with zero pressure or when pumping into an open vessel, use our three-function valve to prevent syphoning. 7
8 V. Start-Up 7. Optional Three Function Valve. Anti-siphon feature allows metering of liquids down hill or into the suction side of a circulating pump. It provides protection against an accidental application of suction pressure at the fluid injection point. Its Teflon coated diaphragm provides a positive anti-siphon action. Back pressure function permits metering into atmospheric discharge (open container) without overpumping. Line check permits removal of discharge tubing without release of system fluid. 8. Priming/bleed valve connection Connect the clear poly tubing to the outlet of the bleed or priming valve. Position the free end of this tube in the chemical container. Standard head configurations include a priming valve built into the head. Clear poly tubing should be connected to the outlet of this valve, the other end of the tube should be placed in the chemical container above the fluid level. A. Front Panel Description All DEMA AG series pumps come with the following standard panel features: 1x16-backlit LCD display POWER PULSE On/Off power indicator light ENTER 100 MENU Press ENTER to test Press MENU to access settings Pulse or Stroke indicator light Up and Down arrow keys for setting adjustments MENU key to enter and exit pump set-up ENTER key to save desired adjustments B. Run Mode Explanation The readout will display one of two modes, Run mode and Set-up mode. Run mode is displayed only while the pump is in normal operation. The display will show the pump speed setting. Manual activation of the relay output and pump stroking can be activated by pressing the ENTER key while the pump is in the run mode. This will manually activate both functions of the unit for 3 minutes. After three minutes the unit goes back to automatic. If the ENTER key is pressed during the 3 minute test, it will revert to automatic. 8
9 C. Set Up Mode Explanation To enter Set-up mode, press MENU. Notice that a cursor appears on the screen signifying that an adjustment can be made. To change the figure above the cursor press the UP or DOWN keys until the desired setting appears, then press ENTER to advance. Continue pressing ENTER to toggle past the other displays. When all settings are made, press MENU to return to run mode, and save settings. See Menu Map on Page 12. D. Priming the Pump 1. Settings Plug in pump, set stroke knob to 100%. 2. Priming/Bleed valve If fluid begins moving up suction line while pump is operating, no further priming is required. If fluid is not moving, open bleed valve approximately one turn until fluid begins to move. When suction line fills, close bleed valve. Do not over tighten bleed valve. Damage may occur. 3. To prime the DEMA AG series pump simply press the ENTER key while the pump is in Run mode. This allows the pump to stroke at the maximum STROKES/MIN setting. E. Stroking Speed or Frequency The DEMA AG series pump allows for an exact number of strokes to be set and read on the front panel LCD meter. It is adjustable from 0 to 125 strokes per minute (0 to 160 for 55 GPD). In addition, for applications requiring very low outputs the speed can be set in strokes per hour from 1 to 125. F. Stroke Length The stroke length can be adjusted on all DEMA Ag pumps. This adjustment is a mechanical adjustment made using the large knob on the control panel. To avoid damage to the pump, this adjustment should only be made while the pump is running at a high stroking rate. Always start adjusting your pump s output down by reducing the pump s stroking speed or frequency. By leaving the stroke length as long as possible you decrease any chance of losing prime. 9
10 G. Calculating Output A pump s output per minute can be determined by dividing the maximum rated gallons per day by 1440 (minutes per day). For example, a 30 gallons per day (gpd) pump at a maximum stroke length and speed setting of 125 strokes per minute (spm) will pump gallons per stroke (gps) = gpm 125 spm = With this value and the pump s speed setting (strokes per minute) you can calculate your pump s output at it s rated pressure. A 30 gpd pump set at 50 strokes per minute: 50spm x gps x 1440 (minutes per day) = gallons per day Reducing the stroke length will reduce the pump s output again. If the example pump above had it s stroke length reduced to 50% the gallons per day output is reduced to (example: gpd x 0.50 = 6.01 gpd) A higher product viscosity will reduce the output. Pressures lower than the pump s rating can increase the output. H. Calibration All DEMA Ag units are factory calibrated. The reading should be verified for accuracy and adjusted as per the instructions listed below. One Point Calibration Units can usually be one point calibrated by leaving the cleaned probe on-line sensing the system water and entering the known system ph or ORP value in the calibration screen. ph Two Point Calibration A two-point calibration allows the user to reset the offset and slope of the ph reading. Occasionally a 2-Point calibration will be required for installations where a one-point calibration is not sufficient or as a probe ages. You should calibrate to the side of ph scale the unit will normally be operating in. For example if the unit is going to be operating in a range of 8 to 9 then use a buffer of 10 ph plus the buffer of Known ph buffer solutions with ph values of 4 or 10 plus a buffer of 7 are required to perform a 2-point calibration. 2. The solution ground lead MUST be in the buffer solution with the ph probe for correct calibration. 3. Rinse probe with buffer to be tested before placing probe in the buffer to prevent buffer contamination. 4. Allow the probe to set in the known buffer for 30 seconds before calibrating. Reset Calibration to Factory Default To return the unit to the original factory calibration defaults cycle power to the unit while pressing in on the down arrow key. Once the power has come back on for five seconds release the key and all user defined calibrations will have been removed. Warnings: 1. Do not allow probe to become dry! Damage will occur and a new probe may be needed. 2. Probes typically last from 6 to 18 months depending upon installation and care. 10
11 VI. Control Options OFF - The OFF control mode will stroke the pump at a user defined rate. From strokes per minute or per hour. ph Control - The ph control mode will allow the pump to stroke proportionately based on high and low ph setpoints. This will allow the pump to stroke faster as the ph reading moves away from the desired control level, and slower as it gets closer to it. ph/flow - The ph/flow control mode uses a multiply/divide feature as part of the programming that allows for an incoming dry contact pulse (such as from a water meter) to dictate how many times the pump will actually stroke. **For example, setting the Multiply to 5 means that a single incoming pulse from a water meter can indicate to the pump that it needs to multiply that by 5, which would cause the pump to stroke 5 times per dry contact pulse that it receives. If the pump was set to Divide that signal by 5, then it would require receiving 5 dry contact pulses from the water meter before the pump would stroke once.** When the multiply/divide is set, low and high ph setpoints with percentage settings can be programmed. The high and low setpoints and percentage settings are used to alter the multiply/divide settings based on how far away the ph reading is from the desired control level. **For instance, if the multiply is set to 5 and the low ph setting is 6.0 with a 20% setting, then if the ph is at 6.0 or lower and the pump receives a dry contact pulse from a water meter, then the pump will only stroke once, or 20% of the multiply setting of 5.** ***The pulse input should receive no more than 1 pulse/second*** 11
12 VII. Menu Map Run Screen (All Modes) ph Reading Pressing Enter: Forced On Feed Status ph Setpoint Control Alarms: High ph and Low ph Flow Alarm Stroke Rate/Min or HR Limit Time Menu Control ph/flow Calibrate? Cal ph= xx.xx OFF Strokes Low ph per: Min or Hr Low Mode: ph Multiply or Divide ph Calibrate? Cal ph= xx.xx Stroke Rate Multiply or Divide: xxxx Low ph Low ph Low ph Stroke Rate Low Rate % High ph High ph: High ph Stroke Rate High Rate% High Alrm: High Alrm: Low Alrm: Low Alrm: Limit: Limit: Reset Lmt: 0-99 Reset Lmt:
13 VIII. Maintenance The DEMA AG series pump is designed for long service life with minimum maintenance. If for any reason, maintenance is necessary or desireable, the DEMA Ag pump is easily maintained. Before any maintenance or service is performed, observe the following precautions: 1. Disconnect the DEMA Ag pump from power source. 2. Drain chemical from discharge tubing. 3. Disconnect discharge tubing from pump. 4. If the DEMA Ag pump is used in a flooded suction application, remove foot valve from chemical container. 5. Observe relevant safety protocols when handling parts which have been in contact with hazardous chemicals. A. Diaphragm Replacement 1. Remove the four screws attaching the fluid end to pump body. 2. Remove the fluid end from the pump body. 3. Unscrew the diaphragm from the pump shaft in a counter-clockwise direction. Be careful that diaphragm support ring does not fall out. 4. Do not allow sharp or abrasive objects to come in contact with pump parts. 5. Inspect end of shaft to assure that threads are in good condition. No further disassembly is recommended. 6. Screw new diaphragm onto pump shaft until it bottoms out on shoulder of shaft. It is not necessary to tighten further. 7. Replace fluid end. Make sure that screws are evenly tightened. 8. Reconnect plumbing and power. Prime the pump. B. Suction and Discharge Check Valve Replacement 1. Disconnect suction tubing from pump. 2. Unscrew fitting from pump head. 3. Remove check valve from suction fitting and replace. 4. Remove O-ring from cavity in fluid end. 5. Remove check valve from suction side pump and replace. 6 Install new O-ring in cavity of fluid end. 7. Replace valve fitting with check valve in fluid end. 8. Replace fluid end. Make sure that screws are evenly tightened. 9. Reconnect plumbing and power. Prime the pump. NOTES: 1. Tighten pump head screws after pump s initial week of operation. 2. When installing check valves, remember that the seats are always installed at the bottom. C. Cleaning Probe 1. Remove the electrode from the system by turning counter-clockwise until fully released. 2. Spray with water and/or detergent, using a soft brush to dislodge any particulate matter. (Cold water applied to a hot probe may cause damage.) 3. Visually inspect the electrode for signs of damage. 4. Calibrate the electrode. 5. Re-mount into the system, avoid twisting on the cable. The ph glass is susceptible to coating by many substances. The speed of resonse, normally 95% of the reading in less than 10 seconds, is dramatically degraded when the ph glass is coated. Slow response or non-reproducible measurements are signs that the electrode has become coated, clogged or dead. ph probes should be replaced annually under good conditions. 13
14 Probes must be installed within 45 of vertical with tip pointed down Coating of an electrode s measuring surface can lead to erroneous readings including shortened span and slow response times. The type of coating determines the type of cleaning technique. Soft Coatings can be removed by vigorous stirring, by use of a squirt bottle, or very carefully, by gently wiping with a soft cloth, clean non-abrasive paper or cloth. DO NOT USE ANY BRUSH OR ABRASIVE CLEANER ON ph GLASS! Hard Coatings should be chemically removed. The chemical used to remove the coating should be the least harsh chemical that dissolves the coating in 1 or 2 minutes and does not attack the electrode s materials of construction. For example, a calcium carbonate coating might be removed with 5% HCI (muriatic acid). Oily or Organic Coatings are best removed with detergents or an appropriate solvent that does not attack the electrode s materials of construction. For example, isopropyl alcohol might be used but acetone should be avoided if the electrode s body is made of CPVC. Pipe Cross Section NOTE: WHEN USING CHEMICALS OR SOLVENTS CARE SHOULD BE TAKEN AND APPROPRIATE EYE, FACE, HAND, BODY AND/OR RESPIRATORY PROTECTION SHOULD BE USED. Abranding or sanding a ph electrode s surface should never be done. However, the measuring surface of an ORP electrode may be gently abraded by use of 600 grade wet silicon carbide paper, jeweler s rouge or very fine steel wool, but try to clean chemically before abrading with 600 paper. Important considerations for ph/orp probes 1. The ph Electrode is shipped in a cap containing a solution of ph 4 buffer and potassium chloride. ORP Electrodes are shipped in caps containing a piece of cotton wetted with tap water. The electrode should remain in the cap until it is used. If the electrode is used infrequently the cap and its solution should be saved and the electrode stored in it. Store ph electrodes in ph 4 buffer if soaking solution is discarded. Remove cap and label to use. 2. After exposure to a sample, buffer or rinse solution, carryover can be minimized by blotting-never by wipingthe electrode with a clean, non-abrasive paper or a clean cloth towel. DO NOT USE A BRUSH ON ph GLASS. 3. Coatings on an electrode s surface prevent new liquids from contacting an electrode s measuring surface and can mimic the effects of electrode aging. Before concluding that an electrode needs replacing check its surface for coatings. When to use a remote transmitter ph and ORP probes require a remote transmitter if the wire run from the probe to the controller is beyond 20 feet (6 meters). 14
15 D. Liquid End Diagram Item Description 1 Complete Head Kit 2 Injection Valve 3 Foot Valve 4 Bleed Valve Assembly 3 E. Replacement Parts Part Assemblies Item Description Part Number 1... Complete Head Assembly 110 psi... CKR- K F C U 2... Injection Valve Assembly...INJ- K F C U 3... Foot Valve Assembly... FTV- K F C U 4... Priming Valve Assembly...PRI- K F C U Body Seat Ball Connection K- Kynar F- Teflon C- Ceramic U- 3/8 Tubing UV Resistant 15
16 IX. Diagrams A. Standard 3/4 Electrode B. T-ADAPT in large pipe 16
17 X. Trouble Shooting PROBLEM CAUSE REMEDY Pump does not achieve Air trapped in suction line Straighten suction line so as to eliminate or maintain prime high spots. Insufficient fluid Foot valve contaminated or improperly installed Excessive lift Suction fittings not properly tightened Worn or contaminated check valves Split or pinch in suction tube Low chemical level Stroke adjustment set too low Worn or contaminated check valves Obstruction in suction line Clogged foot valve screen Output (system) pressure too high Diaphragm worn or torn Electronic failure Inspect foot valve screen and assure that foot valve is in a vertical position below fluid level. Maximum suction lift is 5 feet with water or fluids of similar specific gravity; less with heavier liquids such as acids. Mount pump in a lower position relative to the chemical container. Check fittings. Overtightening may cause restriction. Conversely, if any leakage occurs, pump will suck air and fail to prime. Inspect check valves in fluid end for cleanliness. Clean or replace as necessary. Inspect suction tube through its full length to assure that there are no splits at the connections or other restrictions. Move any objects or equipment which impinges upon suction tube or reroute as required to assure a smooth transition from foot valve to pump. Check fluid level in chemical supply tank. Check operation of stroke limiter knob. If pump delivers too low adjustable rate, check settings. Readjust as required. Inspect, clean or replace as necessary. Check suction line for obstructions, clogging, kinks or pinch points. Clean or replace foot valve screen. Relocate the injector to a lower pressure part of the the system. Replace diaphragm, making sure that it is screwed on fully to shoulder of shaft. Consult dealer or factory. 17
18 Excessive fluid Pump will not pump Pump will not run not plugged in Excessive noise False Reading Will not calibrate Failure or lack of antisiphon valve Excessive stroke rate Improper stroke length System pressure too high Diaphragm improperly installed Check valves worn or clogged Pump not turned on or not plugged in Electronic failure Pump not primed No output pressure Bad or dirty electrode Out of calibration Dirty electrode Faulty electrode Faulty wiring Out of calibration Inspect or add anti-siphon valve. This is caused when system is in a vacuum condition or valve in delivery applications with flooded suction which feeds systems at very low pressures. Lower the stroke rate if adjustable on your pump. Reduce stroke length. Check system pressure to assure that it is within system rated paramaters of the pressure. Make sure that diaphragm is screwed fully unto shaft. Clean or replace as required. Check outlet with meter to assure that correct or voltage is present and that power supply cord is in good condition and plugged in. Consult dealer or factory. Prime pump. Add an anti-siphon valve to provide 25 PSI restriction on pump discharge. Clean, as needed Calibrate unit Clean electrode Replace controller or electrode as needed Calibrate unit 18
19 19
20 20
Manual. MicroTron. Series B. Installation Maintenance Repair. Manual. Chemical Metering Pump
Manual MicroTron Series B Chemical Metering Pump Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com
More informationManual. MicroTron. Series C. Installation Maintenance Repair Manual. Chemical Metering Pump
Manual MicroTron Series C Chemical Metering Pump Installation Maintenance Repair Manual Advantage Controls P.O.Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com
More informationMicroTron Series C. Manual. Installation Maintenance Repair. Manual. Chemical Metering Pump
Manual MicroTron Series C Chemical Metering Pump Installation Maintenance Repair Manual Advantage Controls P.O.Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com
More informationManual. MicroTron. Series A. Installation Maintenance Repair Manual. Chemical Metering Pump
Manual MicroTron Series A Chemical Metering Pump Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com
More informationSolenoid Chemical Metering Pump. Operating Manual
Series S Solenoid Chemical Metering Pump CheckPoint Headquarters CheckPoint UK CP Pumps & Systems FZE 21356 Marion Lane C2/C3 Lombard Centre P.O. Box 262131 Mandeville, Louisiana 70471 Kirkhill Place,
More information8000 Series ph/orp Electrode Platform Product Instructions
8000 Series ph/orp Electrode Platform Product Instructions Introduction Congratulations on your purchase of your Sensorex S8000 series electrode platform. The platform is designed in a modular fashion
More informationTABLE OF CONTENTS. Firmware Version
TABLE OF CONTENTS Firmware Version...1 Environmental Conditions...1 Electrical Specifications...1 Warnings...2 Section A: Programming the Controller...3 A 1: The Program Menu...3 A 1.1: Entering the Program
More informationUni-Dose. For file reference, please record the following data:
For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your Pump or Accessory, please include the complete
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)
INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM) IOM-1088 03-16 Model 1088 Vacu-Gard Blanketing Valve ISO Registered Company SECTION I I. DESCRIPTION AND SCOPE The Model 1088 Vacu-Gard is a tank blanketing
More informationALLSTAR DILUTION CONTROL SYSTEM MODEL 639AG-4-1ABC
MODEL 639AG-4-1ABC 1. PARTS: A. Blend Center assembly B. 5 pc. 1/4 ID x 8 ft. long vinyl supply tubing, with foot valve & ceramic weight C. 1 pc. 1/2 ID x 6 ft. long vinyl outlet tubing D. 2 pc. #8 pan
More informationSignet 3719 ph/orp Wet-Tap
Signet 3719 ph/orp Wet-Tap *3-3719.090* 3-3719.090 Rev H 09/07 English Do not exceed maximum temperature/pressure specifications. Wear safety goggles or face shield during installation/service. Do not
More informationAnalog Condensate Monitor Instruction & Maintenance Manual
Analog Condensate Monitor Instruction & Maintenance Manual Advantage Controls, Inc. PO Box 1472 Muskogee, OK 64402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com EE-13 email: aci@advantagecontrols.com
More informationVSP SERIES Installation, Operation and Maintenance Manual
VSP SERIES Installation, Operation and Maintenance Manual VARIABLE SPEED PERISTALTIC METERING PUMPS VSP-12 and VSP-20 Models READ ALL WARNINGS CAREFULLY BEFORE INSTALLING PUMP PUMP DATA/SPECIFICATIONS
More informationSIGNET 3719 ph/orp Wet-Tap
ENGLISH 3-3719.090 B-6/02 English Do not exceed maximum temperature/pressure specifications. Wear safety goggles or face shield during installation/service. Do not attempt to disassemble the retraction
More informationOperator's Manual Dielman Rock Island Industrial Dr. St. Louis, MO Tel:(314)
Operator's Manual Rev: ev: D08 Operator's Manual TABLE OF CONTENTS Firmware Version...1 Environmental Conditions...2 Electrical Specifications...2 Warnings...3 Section A: Programming the Controller...4
More informationWelker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP
Installation, Operation, & Maintenance Manual Welker Sampler Model GSS-4HP The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct
More informationInstruction Manual. Series E7 Metering Pumps. For file reference, please record the following data:
Instruction Manual Series E7 Metering Pumps For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your
More informationWATCH GUARD 440 SERIES FLOAT VALVES INSTALLATION INSTRUCTIONS MODELS: T, TX, T, BT,
WATCH GUARD 440 SERIES FLOAT VALVES INSTALLATION INSTRUCTIONS MODELS: 440-22T, 440-22TX, 440-23T, 440-23BT, 440-24 Overview The Watch Guard 440 Series of float valves fills and maintains fluids in reservoirs.
More informationInstruction Manual. Series E7 Metering Pumps. For file reference, please record the following data:
Instruction Manual Series E7 Metering Pumps For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your
More informationOPERATOR'S MANUAL FOR DOUBLE ACTING PISTON HAND PUMP
OPERATOR'S MANUAL FOR DOUBLE ACTING PISTON HAND PUMP OPERATION AND SERVICE GUIDE JAN. 00 Refer to Bulletin P-0 and Parts List P-9990. SAFETY PRECAUTIONS. This manual contains important information for
More informationINSTALLATION INSTRUCTIONS DEMA BLEND CENTER MODEL B-GAP, T-GAP
1. PARTS: ITEM DESCRIPTION QTY. A. Blend Center Assembly 1 B. ¼ ID X 8 Long Vinyl Supply Tubing & Foot Valve Assembly 1 C. Ceramic Weight 1 D. ½ ID X 6 Long Vinyl Outlet Tubing (For 4 GPM Station Only)
More informationDEMA BLEND CENTER MODELS: 633GAP INSTALLATION INSTRUCTIONS
The 633GAP Series Blend Center modular design lets you easily couple together any number of stations to create a system that meets your specific needs. Mix and match both high and low flow units for filling
More informationDEMA BLEND CENTER MODELS: 637GAP-1 and 637GAP-4 INSTALLATION INSTRUCTIONS
1. PARTS CHECKLIST: ITEM DESCRIPTION QTY. A. Blend Center Assembly 1 B. ¼ ID X 8 Long Vinyl Supply Tubing & Foot Valve Assembly 4 C. Ceramic Weight 1 D. ½ ID X 6 Long Vinyl Outlet Tubing (For 1 GPM Station
More informationPurging Air From Divider Block Lubrication Systems
FROST ENGINEERING SERVICE Purging Air From Lubrication Systems A D I V I S I O N O F G E C S E Y S A L E S & S E R V I C E DESCRIPTION Divider block lubrication systems operate correctly only when all
More informationInstallation Instructions
Installation Instructions for 15912 to 15916 Electric Fuel Pumps & Fuel Pressure Regulators Installation Instructions WARNING! These instructions must be read and fully understood before beginning the
More informationFor additional information, please visit our website at SENSOR SPECIFICATIONS
Instruction Sheet PN 51A-140/rev.E December 2010 Models 140, 141, and 142 Conductivity Sensors For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. SENSOR/PROCESS
More informationGLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL
GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL PLEASE RECORD THE FOLLOWING DATA (Information is located on the product label or packing slip) Model Number: Date Code: Installation Date: Installation
More informationTWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air
ORIGINAL INSTRUCTIONS Form No.1000458 5 SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet
More informationDEMA BLEND CENTER MODEL 681GAP-3 INSTALLATION INSTRUCTIONS
1. PARTS CHECKLIST: A. Blend Center Assembly B. Vinyl Supply Tubing with Foot Valve Assembly C. Ceramic Weight D. Vinyl Outlet Tubing E. Screw and Anchor Kit F. Label Card G. Metering Tip Kit 2. INSTALLATION:
More informationHALLMARK INDUSTRIES INC
Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge
More informationRosemount 402 and 402VP
Rosemount 402 and 402VP Contacting Conductivity Sensors Instruction Manual LIQ-MAN-402 Rev. M May 2017 hasgkas Essential Instructions Read this page before proceeding! Emerson designs, manufactures and
More informationINSTALLATION & OPERATING INSTRUCTIONS
INSTALLATION & OPERATING INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND-FAULT CIRCUIT-INTERRUPTER. THE UNIT SHOULD BE INSTALLED BY A QUALIFIED SERVICE REPRESENTATIVE.
More informationE.R.I.C. Series Electronic Metering Pump Installation & Operation Manual (Enhanced Control) Manual No.: Revision : 00 Rev.
E.R.I.C. Series Electronic Metering Pump Installation & Operation Manual (Enhanced Control) Manual No.: 54189 Revision : 00 Rev. Date: 03/2016 Note: This manual is a supplement to 54038 Table of Contents
More informationSTAINLESS STEEL DETERGENT INJECTOR AW
STAINLESS STEEL DETERGENT INJECTOR AW-8000-0001 OPERATING INSTRUCTIONS & PARTS LIST CAUTION RISK OF INJURY! READ ENTIRE MANUAL BEFORE OPERATING! THIS MANUAL IS AN IMPORTANT PART OF THE INJECTOR AND MUST
More informationBOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)
LAKEWOOD INSTRUMENTS MODEL 260 SERIES BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD) INSTALLATION & OPERATION MANUAL SERIAL #: Lakewood Instruments 7838 North Faulkner Road, Milwaukee, WI
More informationD/G-03 Maintenance. Shutdown Procedure During Freezing Temperatures. Daily. Periodically
D/G-03 Maintenance NOTE: The numbers in parentheses are the Ref. Nos. on the illustrations in the Parts Manual. Daily Check the oil level and the condition of the oil. The oil level should be 3/4 in. (20
More informationInstruction Manual. Series R Peristaltic Pump. For file reference, please record the following data:
Instruction Manual Series R Peristaltic Pump For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your
More informationNot required for most applications. Not required for most applications. High pressure ( provided) High pressure ( provided)
ELECTRIC FUEL PUMPS P/N 12-801-1, 712-801-1, 12-802-1, 12-802-2, 712-802-1, 12-812, 12-815-1, & 712-815-1 FUEL PRESSURE REGULATORS P/N 12-500, 12-501, 12-803, 12-803BP, 12-804, & 15812NOS Installation
More informationD-04/G-04 Maintenance
D-04/G-04 Maintenance NOTE: The numbers in parentheses are the Ref. Nos. on the illustrations in the Parts Manual. Daily Check the oil level and the condition of the oil. The oil level should be 1/4 in.
More informationTools Needed for Mounting Cleá Filling Station
ALWAYS OBSERVE PRODUCT SAFETY AND HANDLING INSTRUCTIONS. ALWAYS DIRECT DISCHARGE AWAY FROM YOU or other persons. ALWAYS DISPENSE CLEANERS AND CHEMICALS AS DIRECTED ON THE LABEL. ALWAYS DISPENSE INTO APPROVED
More informationChem-Feed Installation Instructions
Chem-Feed Installation Instructions Model C-800, Noir Jr. Positive Displacement Injector Pump PT SARANA PRIMA ENGUNA Jl.Gunung Sahari Raya 84 C Jakarta Phn. 021 4200045 Fax. 021 4200483 www.spe.co.id 80000-211
More informationSINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C
D E M A SINGLE-STAGE MODELS SINGLE-STAGE MODELS 1. PARTS A. Injector B. Backup washer (Models 204C & smaller). C. Ceramic Weight. D. Tubing 8 long w/ foot strainer. E. Three brass nozzle bushings Metering
More information#9040 FUEL TANK SWEEPER
#9040 FUEL TANK SWEEPER INSTRUCTION MANUAL FILTERS AND REMOVES FINE BIO-CONTAMINANTS, ALGAE, ETC. SWEEPING PROCESS REMOVES LARGE CONTAMINANTS FROM OIL TANKS SUCH AS RUST, WATER, CRUDE AND DIRT CIRCULATES
More informationATD-6810 SPRAY GUN W/CUP INSTRUCTION MANUAL
ATD-6810 SPRAY GUN W/CUP INSTRUCTION MANUAL Read this Instruction Manual carefully and understand it completely, basic precaution should be strictly followed to prevent the damage to the tool and injury
More informationSuggested Installation & Operating Instructions for Sidewinder Pumps
Models 40G / H / 80G P.O. Box 80769 Lafayette, LA 70598-0769 (337) 235-9838 FAX (337) 235-9852 www.sidewinderpumps.com Pneumatic Powered - Plunger Pumps Suggested Installation & Operating Instructions
More informationP239-1 Supply Pumper Instructions
P239-1 Supply Pumper Instructions STOP! READ THIS SECTION NOW. The following information is critical to the proper installation and operation of this Oil Supply System! Read it carefully before starting
More informationUser Manual GRX- 950 and GRX- 950 Li
User Manual GRX- 950 and GRX- 950 Li Page 1 of 17 TABLE OF CONTENTS INTRODUCTION 3 BASIC SET- UP 4 TURNING ON YOUR GRX- 950 7 PRECAUTIONS 8 FREE WHEEL MODE 9 GENERAL BATTERY CARE 10 BATTERY INFORMATION
More information1/2" AIR DRIVEN DIAPHRAGM PUMP
1/2" DRIVEN DIAPHRAGM PUMP OPERATION AND SERVICE GUIDE O-1225D NOV. 2008 Page 1 of 6 Refer to Bulletin P-605, Parts List P-9151 DRIVEN, DOUBLE DIAPHRAGM PUMP MANUAL Congratulations on purchasing one of
More informationSuggested Installation & Operating Instructions for Sidewinder Pumps
Model 40 E Series Lube Pump P.O. Box 80769 Lafayette, LA 70598-0769 (337) 235-9838 FAX (337) 235-9852 www.sidewinderpumps.com Pneumatic Powered - Plunger Pumps Suggested Installation & Operating Instructions
More information1-BUTTON DISPENSER INSTALLATION INSTRUCTIONS
R 1-BUTTON DISPENSER INSTALLATION INSTRUCTIONS Model: #91162-00 The Green Earth II 1-button dispenser allows you to dispense one product for mop buckets and automatic scrubbers. The modular design lets
More informationREAD ALL CAUTIONS CAREFULLY BEFORE INSTALLING PUMP SEE PAGE (4) SERIES 100/150 INSTRUCTION MANUAL P/N CDE: IM120 E/07
READ ALL CAUTIONS CAREFULLY BEFORE INSTALLING PUMP SEE PAGE (4) SERIES 100/150 P/N 32040 CDE: IM120 E/07 INSTRUCTION MANUAL TABLE OF CONTENTS Page SAFETY INSTRUCTIONS... 2 INTRODUCTION... 3 PRECAUTIONS
More informationSOLAROY 12 VDC Metering Pump
SOLAROY 12 VDC Metering Pump INSTALLATION, OPERATION, AND MAINTENANCE MANUAL MODEL NUMBER: SR-1PS-TC250 and SR-1PS-TC375 Manual #23858 Revision 2/2012 Precautions / Warnings: Proper fuse installation (to
More informationFAIRCHILD T5420 DIGITAL-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions
FAIRCHILD T5420 DIGITAL-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions Figure 1. T5420 Outline Dimensions. INSTALLATION The Model T5420 can be mounted directly onto a flat surface
More informationLACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31
LACT MEASUREMENT Prepared By: Ken A. Steward. P.E. Linco-Electromatic, Inc. 4580 West Wall Street Midland, Texas 79703 The Operation of L.A.C.T. Units The simplest approach to the understanding of the
More informationInstallation & Operating Manual
Installation & Operating Manual 25IPCC-M 7/08 Edition PC Series C E N T R I F U G A L Congratulations On Your Choice In Purchasing This Webtrol Pump Its Quality is unsurpassed in material and workmanship
More information3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer
SCS 2 BLACK SHADOW SERIES 3.1 DISPENSER ALWAYS OBSERVE PRODUCT SAFETY AND HANDLING INSTRUCTIONS. ALWAYS DIRECT DISCHARGE AWAY FROM YOU or other persons. ALWAYS DISPENSE CLEANERS AND CHEMICALS AS DIRECTED
More informationEJECTORS GENERAL OPERATION & MAINTENANCE MANUAL
EJECTORS GENERAL OPERATION & MAINTENANCE MANUAL The information contained in this manual was current at the time of printing. The most current versions of all Hydro Instruments manuals can be found on
More informationInstructions Manual Roytronic Série P + Electronic Metering pumps
Instructions Manual Roytronic Série P + Electronic Metering pumps 10. Grande Rue 27360 Pont Saint Pierre (FRANCE) TEL: +(33) 232-683-000 FAX: +(33) 232-683-093 www.miltonroy-europe.com Lit# 1990.7 8/2007
More informationINSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET
INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET 1 INDEX 1 TECHNICAL DATA 2 PACK CONTENTS 3 PRE-INSTALLATION INFO 4-5 INSTALLATION 6-8 SETTINGS ADJUSTMENT WITH REMOTE CONTROL 9
More informationOWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS
OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including
More informationWater pump Owner's Manual
Water pump Owner's Manual Safety Precautions I. General Safeguards Please read this operation manual to have a thorough understanding of the content there before use the product. Failure to do so may lead
More information4 - Way Control 4 - Way Control 4 - Way Control with lock
INSTALLATION / OPERATION / MAINTENANCE 1. DESCRIPTION MODEL 0-02 (Full Internal Port) Powertrol Valve This manual contains information for installation, operation and maintenance of the Cla-Val Co. 0-02
More informationEX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.
E X S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s EX Series Electromagnetic FLOW SENSOR instructions EX EX The Leader in Flow Meter Value. Table of Contents General
More informationOPERATING INSTRUCTIONS FINISHER 4300
OPERATING INSTRUCTIONS FINISHER 4300 Model No. BA-FS43 Banner American Products, Inc. Temecula, CA Table of Contents I. For Your Safety... 2 II. Electrical Safeguards... 2-3 III. Specifications... 3 IV.
More informationD28 SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER. D28 B D28 E D28 Dual Power B D28 Dual Power E D28 Box D28 Box E
D28 SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER D28 B D28 E D28 Dual Power B D28 Dual Power E D28 Box D28 Box E 1 INDEX 1 TECHNICAL DATA 2-4 PACK CONTENTS 5 PRE-INSTALLATION INFO 6-11
More informationSteam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions
INSTALLATION AND MAINTENANCE INSTRUCTIONS IM-8-002-US October 2016 Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions These instructions should be read by the Company
More informationDESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS
DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS INTRODUCTION The two most common methods of measuring the volume of petroleum liquids are tank gauging and liquid metering. The problems associated with
More informationETF-600 Sensor Operated Lavatory Faucet
INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED LAVATORY FAUCET ETF-600 I.I. Code No. 0816318 ETF-600 Sensor Operated Lavatory Faucet Includes Instructions for Installation of Optional Back Checks
More informationSpray Clean 606T-2 Installation Instruction
Spray Clean 606T-2 Installation Instruction Overview The 606T-2 unit is designed to be used as a spray or foam unit where up to two chemicals can be attached to the unit along with a clean water rinse.
More informationAirless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure
INSTRUCTIONS DP-6376 Airless Spray Gun 5000 psi (345 bar) Maximum Working Pressure INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Table of Contents Warnings......................................
More informationModel 8329 Table of Contents
SERVICE & OPERATING MANUAL Original Instructions Instructions Sheet: 670991 Model 8329 Table of Contents Engineering Data and Temperature Limitations... 1 Performance Curve... 2 Dimensions... 3 Metric
More informationTABLE OF CONTENTS INTRODUCTION.3 WARRANTY INFORMATION 4 SAFETY INFORMATION 5 PREPARING YOUR WATER BEFORE INSTALLATION 6
USER S GUIDE TABLE OF CONTENTS INTRODUCTION.3 WARRANTY INFORMATION 4 SAFETY INFORMATION 5 PREPARING YOUR WATER BEFORE INSTALLATION 6 TOOLS AND PARTS REQUIRED FOR INSTALLATION 7 INSTALLING YOUR SYSTEM PLUMBING..8-9
More informationT21 Thermal Differential Switch
T21 Thermal Differential Switch General Instructions The T21 Point Level Switch is a state-of-the-art in liquid level and interface measurement and control. Level detection is accomplished by using a high-resolution
More informationELECTRIC FUEL PUMPS P/N , , & FUEL PRESSURE REGULATOR P/N
ELECTRIC FUEL PUMPS P/N 80000100, 80000101, & 80000102 FUEL PRESSURE REGULATOR P/N 80000103 Installation Instructions 199R10583 These instructions must be read and fully understood before beginning the
More informationDEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET
I-736 Pg. 1 of 10 Summary The 258BD-200C Drain Master is designed to feed chemicals into drains and grease traps to break up grease, detergent buildup and eliminate odors. The 258BT-200C Trash Master is
More informationOperating Manual for. Dispenser. Read this manual thoroughly before operating the Labmax Bottle Top Dispenser!
Operating Manual for Dispenser Read this manual thoroughly before operating the Labmax Bottle Top Dispenser! General Safety Precautions When using the Labmax please observe the following safety precautions
More informationClose-Coupled Centrifugal Pumps 316 Stainless Steel, Bronze and Cast Iron Models
316 Stainless Steel, Bronze Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain
More informationDISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A
INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. DISPLACEMENT PUMP 308190 Rev. K 3000 psi (210 bar) MAXIMUM WORKING PRESSURE Model
More informationPro Gun (Model: UCpro and UCPro Plus)
Undercoating/Rustproofing Pro Gun (Model: UCpro and UCPro Plus) Professional Undercoating and Rustproofing gun designed to apply protective coatings such as waterborne and solvent based under coatings,
More information5020 Series Injector
5.2018.9.k 1 5020 Series Injector 1 2 3 4 5 6 10 11 7 12 13 8 2 14 Parts List 15 16 17 Item # Part # # Reqd. Description Material Alternate Part # 1 A-1854 1 0-12 PSI Pressure Gauge A-1295SS 2 A-0022 1
More informationEH Series High Viscosity Electronic Metering Pumps Instruction Manual
EH Series High Viscosity Electronic Metering Pumps Instruction Manual Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA TEL 508-429-1110 FAX 508-429-7433 WEBSITE: www.iwakiamerica.com Notice
More informationOperation and Maintenance Manual
TABLE OF CONTENTS Warnings... 1 Firmware Version... 2 Environmental Conditions... 2 Electrical Specifications... 2 Applicable Sensor Operating Ranges... 2 Section A: Programming the Controller... 3 A 1:
More informationLABORATORY ZERO AIR GENERATOR MODEL N-GC1500 USER S MANUAL
LABORATORY ZERO AIR GENERATOR MODEL N-GC1500 USER S MANUAL Content 1. Introduction...2 2. Important safety instruction...3 3. System component...4 4. Engineering design overview...5 5. Installation...6
More informationD Instructions/Parts. Siphon Feed Detail Spray Gun D
Instructions/Parts D-5-55 Siphon Feed Detail Spray Gun FOR PRODUCT INFORMATION CALL: 1-800-742-7731 309991D Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.
More informationAir Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL
Air Operated Double Diaphragm Pump M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL 0.5 I.O.M rev 05. 12/2015 INDEX Title Section Introduction.1 Safety.2 Warranty, General
More informationIMPORTANT SAFETY INSTRUCTIONS
OWNER S MANUAL FLO-MASTER XP2 SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
More informationSelf-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More information36-1 DP PLEASE READ BEFORE USING THIS EQUIPMENT
36-1 DP PLEASE READ BEFORE USING THIS EQUIPMENT DP 36-1 Assembly Instructions PLEASE READ INSTRUCTIONS COMPLETELY BEFORE STARTING We thank you for purchasing the DP-36 pressure system. This system has
More informationTABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color
Blend Safe II Dispensing System is a modular, locking dispensing system that allows user to dispense chemicals safely, control dispenser inventory and has the flexibility in the field to meet changing
More informationM-3025CB-AV Fuel Pump
SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...
More informationOXYGEN GENERATING SYSTEMS INTL. Oxygen System Start-up, Overview and Maintenance Guide
OXYGEN GENERATING SYSTEMS INTL. Oxygen System Start-up, Overview and Maintenance Guide OXYGEN GENERATOR SYSTEM START-UP STEP 1 Walk around the skid and inspect for damage. Then check that all electrical
More information3 Spin Klin Battery Operation and Maintenance Manual
3 Spin Klin Battery Operation and Maintenance Manual Operation During the filtration stage, water flows through the INLET manifold and is distributed through the 3 x 2 backwash valves into the S.K. filters.
More informationVARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines
VARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines Installation and Users Manual For the following Prelube Kits: VARNA Products P/N 6423 Kit for 208 VAC 3 Phase VARNA Products
More informationFPS- 80. Manual. Reverso Pumps, Inc. Ph: (954)
FPS- 80 Manual Table of Contents System Overview... 1 Control Panel Overview... 2 Technical Specifications... 3 Electrical and Installation... Tank Diagrams... 5 Initial Setup... 6 Digital Timer Instructions:
More informationARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82
E X S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s EX Series Electromagnetic FLOW SENSOR instructions EX EX The Leader in Flow Meter Value. Table of Contents General
More informationInstruction Manual. ROYTRONIC EXCEL Series AD Electronic Metering Pumps
Instruction Manual ROYTRONIC EXCEL Series AD Electronic Metering Pumps For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering
More informationOperating instructions Form no safety definitions
Operating instructions Form no. 1000437 safety definitions safety symbols are used to identify any action or lack of action that can cause personal injury. Your reading and understanding of these safety
More informationDEMA SPRAY STATION II MODEL 606T-2 INSTALLATION INSTRUCTIONS
The 0T-2 Spray Station II Dispensers are used in any application where a chemical product must be sprayed or foamed without the use of compressed air or a high pressure pump. City water pressure and optional
More informationMECHANICAL FUEL METER. FM-100 and FM-200 Series Owner s Manual
MECHANICAL FUEL METER FM-100 and FM-200 Series Owner s Manual To the owner Congratulations on receiving your GPI Mechanical Fuel Meter. We at GPI are pleased to provide you with a fuel meter designed to
More informationThe 606T-2 unit is designed to be used as a spray or foam unit where up to two chemicals can be attached to the unit along with a clean water rinse.
Overview The 606T-2 unit is designed to be used as a spray or foam unit where up to two chemicals can be attached to the unit along with a clean water rinse. The unit features three ball valves for control
More information