DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET
|
|
- Jessica Wilson
- 5 years ago
- Views:
Transcription
1 I-736 Pg. 1 of 10
2 Summary The 258BD-200C Drain Master is designed to feed chemicals into drains and grease traps to break up grease, detergent buildup and eliminate odors. The 258BT-200C Trash Master is designed to spray into trash bins and eliminate odors. All programming is done by use of a set of DIP switches that determine the various times and amount of chemical to be dispensed. Please read all instructions before proceeding with Drain Master installation. Assembly Some assembly is required before installing the unit. This involves assembling the vacuum breaker and the injector manifold to the main Drain Master unit. The following steps describe the procedure. See illustration of assembly on page 1. The inlet of the siphon breaker should be installed onto the ¼ pipe that is along the side of the drain master assembly. 2. The injection manifold assembly should be installed onto the outlet of the siphon breaker. Note: A thread sealant should be used to eliminate external leakage. Additionally, do not over tighten the metal to plastic thread joints. Survey Location Determine a location to hang the Drain Master on a wall near the drain or grease trap to be supplied with the chemical product. When using the power adapter, the location should be near an AC wall outlet. The Drain Master can be hung on the wall by use of the supplied wall bracket kit. When mounting the unit in an exterior location the unit should be protected from moisture. Electrical Hookup: Open the cover on the Drain Master and find the female power jack on the control board. Feed the male jack on the power cord through the split bushing on at the bottom of enclosure. Connect the power cord jack to the jack on control board. Connect the 9V battery to the control board and place battery in battery holder. At this point the LED on control board should be on. Plug power cord into a 120V 60Hz wall outlet. Tubing Connections Water should be connected to the inlet of valve with ¼ O.D. copper tubing. The valve is designed to operate at a maximum of 90 psi water pressure. There is a bag of metering tips that can be used to set the induction rate of chemical product. There is a chart that provides some induction rates. However, it should be noted that the actual rate may vary due to water pressure and the viscosity of chemical product. It is suggested that after the setup is complete that the induction rate is measured to assure that the setup is satisfying the application. The chemical pickup is achieved by use of the ¼ I.D. clear vinyl tubing/foot strainer assembly. The tubing is 8 feet long, if needed the tubing can be cut to a shorter length. Place the ceramic weight over the end of I-736 Pg. 2 of 10
3 tubing without the foot strainer. Slide the ceramic weight down the tube until it is resting against the foot strainer. The weighted end of the tubing should be dropped into the container of chemical product. The other end of tubing should be fitted over the plastic barb fitting on the side of the injector. The outlet of the injector has a ¼ plastic compression fitting assembled to it. There is 20ft of ¼ LDPE tubing that can be fitted into the ¼ plastic compression fitting. Depending on if this is a drain (258BD) or trash (258BT) installation determines what will be done to the outlet of the LDPE tubing. Drain Installation The drain installation will simply require that the end of the tubing be secured to the drain pipe or grease trap such that the drain product can be delivered to the desired location. The LDPE tubing should be secured along its route from the Drain Master to the outlet of the LDPE tubing. Trash Installation The trash installation will utilize the spray nozzle and plastic 1/8 FPT x ¼ compression fitting so that the chemical product can be sprayed on the contents of a trash container. The 1/8 FPT on the plastic compression fitting should be assembled to the 1/8 MPT on the brass spray nozzle. The LDPE tubing can be fitted to the plastic compression fitting. The spray nozzle should then be secured over the trash container. The LDPE tubing should also be secured along its route to from the Drain Master unit to the spray nozzle. In both installations the tubing can be cut to shorter length to accommodate a custom fit, or if necessary a longer pieces of tubing can be ordered from DEMA Engineering Company. Programming: Open the cover on the Drain Master. All of the DIP switches should be visible on the control board on the backside of the cover. All of these switches must be in the off position to begin programming. Time Set: Find the DIP switch that corresponds to the closest hour of the current time. There are 12 DIP switches for AM and 12 for PM. After finding the correct switch flip it to the on position. The time set LED will go out. Feed Time: Using the same switches set the hours in which the Drain Master should operate by switching the appropriate switch to the on position. Note: If the DIP switch that was set for the time set is not a desirable feed time, simply turn that switch to the off position. But not until at least one feed time has been selected. This will insure that the time set will not be lost. Dosage: There are a series of 6 DIP switches that are labeled dosage. The number labeled next to each switch indicates the number of units of time to be dispensed. A unit of time is equal to 1 minute. Example: switch 2 will dispense for 2 units of time or 2 minutes. These may be added together for higher doses. Example: Switches 5 and 6 in the on position will dispense for 11 units of time or 11 minutes. The maximum is 21 units of time or 21 minutes when all of the switches have been set to the on position. Reprogram: Flip all the DIP switches to off position. I-736 Pg. 3 of 10
4 Priming After installation is complete the pump and tubing will need to be primed so that chemical product will be delivered when the Drain Master is running. This is simply done by pressing and releasing the prime button on the front of the Drain Master; the pump should begin to run. The pump will run for the amount of dose that has been set. Note: At any time the Drain Master pump can be shut off by simply pushing the prime button again. Testing and adjustments Follow these steps to determine the proper induction rate: 1. Use a measurable container such as a graduated cylinder. 2. Pour an amount of the chemical product into the test container. Be sure to note the amount of chemical that is in the container while the vinyl pickup tube is in the container. 3. Select a metering tip that appears close to the desired rate based on the supplied metering tip chart. If not sure, then use a tip that is in the middle such as the red or white metering tip. 4. Press the prime button on the unit. It will run for the amount of time that has been set with the DIP switches that are identified as dose. Remember the time is 1 minute per each unit of time setting. See programming section for more information about dose setting. 5. Measure the amount of chemical that has been removed from the container after unit has run for the set time. 6. This procedure may need to be repeated to assure accuracy. 7. A rate can be established by dividing the amount of chemical inducted by the amount of time. 8. If the rate is significantly different than the target rate, it may be necessary to use either a larger are smaller metering tip to get into a range that will be desirable. If the rate looks satisfactory, the amount of chemical dispensed can be set by adjusting the time by use of the dose DIP switches. Again remember that for every time unit set the Drain Master will dispense for 1 minute. I-736 Pg. 4 of 10
5 Replacement Parts and Assembly and Wiring Diagrams Replacement Parts Item No. DEMA Part No. Description Amount Required Electrical Enclosure Assembly Electrical Enclosure Cover Electrical Enclosure Hinge Kit Drain Master Electronic Control Board Control Board Screw #10-32 x ½ Screw #10-32 Nut Lock washer C2.2 Valve Bracket Gasket Captive Screw for Electrical Enclosure Cover ½ Hole Plug Split Bushing AC to DC Adapter (U.S., 120V 60Hz 1.2A) 1 14 L715.1 Drain Master Label Volt Alkaline Battery (Not Included) Wall Bracket Kit 1 17 L732.1 Pump Blank Label 1 18 P442.PP3 Valve Assembly (See valve diagram for individual parts) Black Cable Assembly Red Cable Assembly ¼ x 3 Long Schedule 40 Plated Brass Pipe ¼ NPT Plated Brass Elbow ¼ x 6 Long Schedule 40 Plated Brass Pipe ¼ Street Elbow ¼ x 1/8 pipe adapter See Injector Parts Chart and Diagram /8 FPT x ¼ Compression Fitting (Plastic) 1-258BD 2-258BT LA Vacuum Breaker Assy K Metering Tip Kit ft ¼ LDPE Tubing Tie Wrap Ceramic Weight for ¼ Vinyl Tubing ft Vinyl Tube with Foot Strainer Assembly Spray Nozzle ¼ MPT X ¼ Comp. Elbow 1 See the diagrams on the following pages to aid in identifying parts. I-736 Pg. 5 of 10
6 INSTALLATION DIAGRAM INJECTOR (SEE INJECTOR DIAGRAM 29 1/4" COPPER TUBE (NOT INCLUDED) WATER SUPPLY CHEMICAL CONTAINER (NOT INCLUDED) SPRAY NOZZLE (258BT ONLY) 1/8 FPT X 1/4" PLASTIC COMPRESSION FITTING (258BT ONLY) I-736 Pg. 6 of 10
7 V WALL TRANS POWER JACK 9V BATTERY HOLDER 10 2 I-736 Pg. 7 of 10
8 Valve Replacement Parts Item No. DEMA Part No. Description Amount Required Enclosing Tube Plunger Closing Spring Valve Body Strainer Screen O-ring Screen Cap Diaphragm #8 x ½ Hi-Lo Screw #8 x 3/8 Hi-Lo Screw Bracket VDC Coil Assembly 1 I-736 Pg. 8 of 10
9 INJECTOR ASSEMBLY C Injector Replacement Parts Item No. DEMA Part No. Description Amount Required Screws for Metering Knob T Metering Knob Check Valve O-ring P Check Valve Ball Check Valve Spring Check Valve Core Metering Knob O-ring No. 1 Water Nozzle Back Up Washer C Injector Body 1 I-736 Pg. 9 of 10
10 WIRING DIAGRAM DIP SWITCHES DOSE SETTING 12V WALL TRANSFORMER POWER JACK DIP SWITCHES TIME SETTING 9V BATTERY HOLDER NOTE: POLARITY NOT REQUIRED WITH SOLENOID VALVE HOOKUP. Warranty and Return Policy Warranty DEMA products are warranted against defective material and workmanship under normal use and service for one year from the date of manufacture. This limited warranty does not apply to any products, which have a normal life shorter than one year or failure and damage caused by chemicals, corrosion, improper voltage supply, physical abuse, or misapplication. Rubber and synthetic rubber parts such as O rings, diaphragms, squeeze tubing and gaskets are considered expendable and are not covered under warranty. This warranty is extended only to DEMA the original buyer of DEMA products. If products are altered or repaired without prior approval of DEMA, this warranty is void. Return Policy No merchandise may be returned for credit without the written permission of DEMA Engineering Company. A return merchandise authorization (RMA) number is required in advance of return. I-736 Pg. 10 of 10
DEMA 259B DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET
I-707 Pg. 1 of 7 Summary The 259B Drain Master is designed to feed chemicals into drains and grease traps to break up grease, detergent build up and eliminate odors. All programming is done by use of a
More informationDEMA MODELS P203CTC.PI.1,.2,.3 INSTALLATION INSTRUCTIONS
I. PARTS: A. 1 pc. Cyclone Portable Injector B. 1 pc. Foot Strainer & 1/4" I.D. Tubing. C. 1 pc. Ceramic Weight. D. 1 pc. Instruction Sheet D. 2 pc. 3 hose w/ female x female GHT fittings on both ends
More informationDEMAMaster TM DM-811 Series Installation Manual
R TM MADE IN USA I-807 Page 1 of 6 System Overview The DEMAMaster series is designed for long reliable use with simplicity in mind for both the installer and user. The DEMAMaster dispenses using the reliable
More informationTABLE 1. * SPECIFY S Stainless Steel Knob Part No S or Part No ST (for tips) for pressure exceeding 700 PSI.
1. PARTS A. Injector B. Ceramic Weight. C. Plastic tubing 8' long with foot strainer. 2. INSTALLATION The injector may be installed in any position in the water line with the arrow in the direction of
More informationDEMA 652 DUO-FEED INSTALLATION INSTRUCTIONS
I. PARTS: A. Dispenser assembly B. 1 pc. ½ in I.D. X 6 ft. vinyl outlet tubing C. 1 pc. 9/16 in. I.D. X 6 ft. vinyl outlet tubing. D. 2 pc. 3/8 in. O.D. X 8 ft. vinyl supply tubing, foot valve & ceramic
More informationDEMA SPRAY CLEAN MODELS: 241CDF & 241CDFT INSTALLATION INSTRUCTIONS
1. PARTS A. Bottle holder and injector assembly. B. Spray gun (Model 40-8B). C. 4 mounting screws in envelope. 2. INSTALLATION Mount the bottle holder on wall using the 4 screws provided through the plates
More informationDEMA SPRAY CLEAN MODELS: 244CDF & 244CDFT INSTALLATION INSTRUCTIONS
I. PARTS: A. Injector. B. Spray gun. C. Mounting screws and washers. D. Vinyl supply tubing, foot strainer & ceramic weight. E. Metering tip (specified size, model 244CDFT only). II. INSTALLATION: (See
More informationDEMA 951 FLUSH MANIFOLD WITH 24V DC VALVE INSTALLATION INSTRUCTIONS
System Overview The DEMA 951 Flush Manifold is designed for long reliable use with simplicity and adaptability in mind. The 951 Flush Manifold can be added to the DEMA Atlas 844P, and DEMA Laundry Master
More informationDEMA MODELS 606T INSTALLATION INSTRUCTIONS
I. PARTS: A. Select-O-Spray Assembly B. 2 Pcs. Foot Strainers & 1/4" ID Tubing C. 4 Pcs. Mounting Screws & Anchors D. 1 Pc. 100-15K Metering Tip Kit TABLE 1 Hose I.D. 3/8" 1/2" 5/8" Max. Length 15 ft.
More informationDEMA MODEL 604T-WI INSTALLATION INSTRUCTIONS
DEMA MODEL 604T-WI I. PARTS: A. Select-O-Matic Assembly B. 2 Pcs. Foot Strainers & 1/4" ID Tubing C. 4 Pcs. Mounting Screws & Anchors D. 1 Pc. 100-15K Metering Tip Kit (604T Only) E.1 Pc. Backflow Preventer
More informationDEMA MODEL 606T-WI INSTALLATION INSTRUCTIONS
DEMA MODEL 606T-WI INSTALLATION INSTRUCTIONS I. PARTS: A. Select-O-Spray Assembly B. 2 Pcs. Foot Strainers & 1/4" ID Tubing C. 4 Pcs. Mounting Screws & Anchors D. 1 Pc. 100-15K Metering Tip Kit E. 1 Pc.
More informationDEMA RAPID FIRE MODELS 6300, , , , 6310, 6300H 6300E, 6300EH, &6310E INSTRUCTION SHEET
I-1002 Pg. 1 of 12 PURPOSE: The RAPID FIRE is a spray system designed with a single knob to control OFF, RINSE and up to two chemicals using a single chemically resistant plastic injector. There is full
More informationSpray & Foam Dispenser Item #
Spray & Foam Dispenser Item #92364-00 Spray & Foam Dispenser Item #92364 Table of Contents Section Page 1. Spray & Foam Dispenser Description... 3 2. Spray & Foam Dispenser Installation... 4 3. Chemical
More informationDEMA MODEL 692T FOAM STATION I INSTALLATION INSTRUCTION
1. PARTS CHECKLIST: ITEM DESCRIPTION QTY. A. Foam Station Assembly 1 B. #10 Screw & Anchor Kit Set (Total: 4 Screws & 4 Anchors) 1 C. Ceramic Weight 1 D. ¼ ID Tubing & Foot Valve Assembly 1 E. Metering
More informationDEMA MODEL 603T-WI INSTALLATION INSTRUCTIONS
DEMA MODEL 603T-WI I. PARTS: A. Select-O-Matic Assembly B. 2 Pcs. Foot Strainers & 1/4" ID Tubing C. 4 Pcs. Mounting Screws & Anchors D. 1 Pc. 100-15K Metering Tip Kit (603T Only) E. 1 Pc. Backflow Preventer
More informationDEMA SPRAY CLEAN MODELS: 244BC, 244BCE, 244BCP & 244BCT INSTALLATION INSTRUCTIONS
I. PARTS: A. Injector. B. Spray gun. C. Mounting screws and washers. D. Vinyl supply tubing, foot strainer & ceramic weight. E. Metering tip (specified size, model 244BCT only). II. INSTALLATION: (See
More informationDEMA Model 294D Spray Foam INSTALLATION INSTRUCTIONS
1. PARTS A. Foamer Assembly B. Plastic chemical supply tubing w/ foot valve and ceramic weight C. Metering tip kit D. Outlet hose 25 long (optional accessory) E. Shut-off valve (optional accessory) 2.
More informationDEMA SPRAY CLEAN DISPENSERS MODEL 605T INSTALLATION INSTRUCTION
The 605T Spray Clean Dispenser is used in any application where a chemical product must be sprayed or foamed without the use of compressed air or a high pressure pump. City water pressure and optional
More informationDEMA SPRAY STATION II MODEL 606T-2 INSTALLATION INSTRUCTIONS
The 0T-2 Spray Station II Dispensers are used in any application where a chemical product must be sprayed or foamed without the use of compressed air or a high pressure pump. City water pressure and optional
More informationDEMA MODEL 693T FOAM STATION II INSTALLATION INSTRUCTION
1. PARTS CHECKLIST: 2. INSTALLATION: DEMA MODEL 93T FOAM STATION II ITEM DESCRIPTION QTY. A. Foam Station Assembly 1 B. ¼ ID Tubing & Foot Strainer 1 C. 3/ ID Tubing & Foot Strainer 1 D. Ceramic Weight
More informationSINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C
D E M A SINGLE-STAGE MODELS SINGLE-STAGE MODELS 1. PARTS A. Injector B. Backup washer (Models 204C & smaller). C. Ceramic Weight. D. Tubing 8 long w/ foot strainer. E. Three brass nozzle bushings Metering
More informationDEMA 651AG SINGLE-FEED INSTALLATION INSTRUCTIONS
I. PARTS: A. Dispenser assembly B. 1 pc. 9/16 in. I.D. X 6 ft. vinyl outlet tubing (4 GPM proportioner only). C. 1 pc. 3/8 in. O.D. X 8 ft. vinyl supply tubing, foot valve & ceramic weight. D. 4 pc. #10
More informationSpray Clean 606T-2 Installation Instruction
Spray Clean 606T-2 Installation Instruction Overview The 606T-2 unit is designed to be used as a spray or foam unit where up to two chemicals can be attached to the unit along with a clean water rinse.
More informationDEMA BLEND CENTER MODELS: 633GAP INSTALLATION INSTRUCTIONS
The 633GAP Series Blend Center modular design lets you easily couple together any number of stations to create a system that meets your specific needs. Mix and match both high and low flow units for filling
More informationDEMA BLEND CENTER MODELS: 637GAP-1 and 637GAP-4 INSTALLATION INSTRUCTIONS
1. PARTS CHECKLIST: ITEM DESCRIPTION QTY. A. Blend Center Assembly 1 B. ¼ ID X 8 Long Vinyl Supply Tubing & Foot Valve Assembly 4 C. Ceramic Weight 1 D. ½ ID X 6 Long Vinyl Outlet Tubing (For 1 GPM Station
More informationDEMA SINGLE-FEED MODEL: 651GAP& 651GAP-1 INSTALLATION INSTRUCTIONS
The Model 65GAP is designed to dispense one product into a kitchen sink with the turn of a ball valve. I. PARTS: ITEM DESCRIPTION QTY. A Dispenser Assembly B ½ ID X 6 Long Vinyl Outlet Tubing (For 4 GPM
More informationDEMA MODEL 582 FOAM STATION III INSTRUCTION SHEET
I-866 Pg. 1 of 6 1. PURPOSE: The purpose of the DEMA 582 Foam Station III is to allow a remotely located chemical product source (i.e. a tote) to supply up to three DEMA 582 foam stations without the need
More informationINSTALLATION INSTRUCTIONS DEMA BLEND CENTER MODEL B-GAP, T-GAP
1. PARTS: ITEM DESCRIPTION QTY. A. Blend Center Assembly 1 B. ¼ ID X 8 Long Vinyl Supply Tubing & Foot Valve Assembly 1 C. Ceramic Weight 1 D. ½ ID X 6 Long Vinyl Outlet Tubing (For 4 GPM Station Only)
More information1-BUTTON DISPENSER INSTALLATION INSTRUCTIONS
R 1-BUTTON DISPENSER INSTALLATION INSTRUCTIONS Model: #91162-00 The Green Earth II 1-button dispenser allows you to dispense one product for mop buckets and automatic scrubbers. The modular design lets
More informationWATCH GUARD 440 SERIES FLOAT VALVES INSTALLATION INSTRUCTIONS MODELS: T, TX, T, BT,
WATCH GUARD 440 SERIES FLOAT VALVES INSTALLATION INSTRUCTIONS MODELS: 440-22T, 440-22TX, 440-23T, 440-23BT, 440-24 Overview The Watch Guard 440 Series of float valves fills and maintains fluids in reservoirs.
More informationDEMA BLEND CENTER MODEL 681GAP-3 INSTALLATION INSTRUCTIONS
1. PARTS CHECKLIST: A. Blend Center Assembly B. Vinyl Supply Tubing with Foot Valve Assembly C. Ceramic Weight D. Vinyl Outlet Tubing E. Screw and Anchor Kit F. Label Card G. Metering Tip Kit 2. INSTALLATION:
More informationDEMA Pro-Fill II Sink Dispenser
DEMA Pro-Fill II Sink Dispenser MODELS PF652GAP, PF652AG, PF652GAP-2M, & PF652AG-2M Overview The PRO-FILL II Sink Dispenser mixes water with cleaning chemicals and dispenses these solutions. This unit
More informationTABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color
Blend Safe II Dispensing System is a modular, locking dispensing system that allows user to dispense chemicals safely, control dispenser inventory and has the flexibility in the field to meet changing
More informationDEMA Pro-Fill I Sink Dispenser
DEMA Pro-Fill I Sink Dispenser MODELS PF651GAP, PF651AG, PF651GAP-1M, & PF651AG-1M Overview The PRO-FILL I Sink Dispenser mixes water with a cleaning chemical and dispenses the solution into holding containers
More informationTrident Laundry Chemical Delivery System
Trident Laundry Chemical Delivery System Installation and Setup Guide The DEMA Trident is a complete laundry chemical delivery system for commercial laundry applications. The Trident features Bluetooth
More informationDEMA SINGLE PRODUCT LAUNDRY MASTER TM W/BLEACH OPTION INSTALLATION INSTRUCTIONS LIQUID MODEL 840 (B)(S)
LIQUID MODEL 840 (B)(S) DEMA Engineering Company 10020 Big Bend Blvd. St. Louis, MO 63122 (800) 325-3362 or (314) 966-3533 www.demaeng.com Rev B-34251 2/27/09 Page 1 of 11 LIQUID MODEL 840 (B)(S) Model
More informationTrapper Drain Maintenance/Odor Control Chemical Dispensing
Trapper Drain Maintenance/Odor Control Chemical Dispensing Overview The DEMA Trapper is a digital chemical dispenser that is designed to deliver chemicals for both drain and odor control. The system will
More informationThe 606T-2 unit is designed to be used as a spray or foam unit where up to two chemicals can be attached to the unit along with a clean water rinse.
Overview The 606T-2 unit is designed to be used as a spray or foam unit where up to two chemicals can be attached to the unit along with a clean water rinse. The unit features three ball valves for control
More informationDEMA Dispensing. Overview. Warnings. I-1205 Rev. B a digital ware. The DEMA. Nitro Plus is. tee.
DEMA Nitro Plus Ware Wash Chemical Dispensing Overview The DEMA Nitro Plus is a digital ware wash dispenser designed to dispense cleaning chemicals into ware wash and dish machines. The unit is triggered
More informationDART Ware Wash Speed Control
DART Ware Wash Speed Control Overview Simple and value best describe the DEMA Dart. The system is extremely easy to setup and program. The Dart is suitable to deliver detergent, rinse aid and sanitizer
More informationItems # and #
D I S P E N S E R T E C H N I C A L M A N U A L Items #91160-00 and #91161-00 1. System Description... 1 2. Equipment Included with the Green Earth II XL System... 2 3. Components Included with Green Earth
More informationPeroxiDraw Dispenser
The PeroxiDraw Dispensing System is a locking dispensing system that allows the user to dispense Green Earth Peroxide Cleaner for up to six different dilutions and applications safely and effectively.
More information665 Series Dispenser. Metering tip kit
665 Series Dispenser Metering tip kit Box Contains Mounting hardware, template & key set Instruction sheet 665 series dispenser 4 SafeLink cap assemblies OR Bulk tubing, 4 ceramic weights and foot valves
More informationDEMA DILUTION-AT-HAND EXTREME 800 Series Chemical Dispensers
DEMA DILUTION-AT-HAND EXTREME 800 Series Chemical Dispensers Overview The DILUTION-AT-HAND EXTREME chemical dispenser series combines the proven technology of the DEMA DILUTION-AT-HAND with a new look
More informationD EMA TWO-STAGE INJECTOR MODELS 233, 234A, 236A, 236-8, 238, AND 2312 INSTALLATION INSTRUCTIONS FIGURE 3 FIGURE 2
1. PARTS A. Injector B. Three brass nozzle bushings. C. Plastic Tubing 8 long with foot strainer. D. Ceramic Weight 2. INSTALLATION A. Selecting the nozzle bushing: Refer to Section 4 APPLICATIONS and
More informationDEMA Nitro for Europe Ware Wash Chemical Dispensing
DEMA Nitro for Europe Ware Wash Chemical Dispensing Overview The DEMA Nitro is a digital ware wash dispenser designed to dispense cleaning chemicals when signals are received from ware wash and dish machines.
More information900-WC OWNER S MANUAL THIS UNIT DOES NOT INCLUDE AWATER BACKFLOW PREVENTER, CHECK LOCAL PLUMBING CODES FOR PROPER INSTALLATION. Pg.
900-WC OWNER S MANUAL THIS UNIT DOES NOT INCLUDE AWATER BACKFLOW PREVENTER, CHECK LOCAL PLUMBING CODES FOR PROPER INSTALLATION. Pg. 1 of 6 900-WC FRONT VIEW - CONTROL BOX COVER REMOVED Pg. 2 of 6 04/04/07
More informationDEMA S.U.D.S Jr. SINGLE PRODUCT LAUNDRY 581K(I)(S)(V)
DEMA S.U.D.S Jr. SINGLE PRODUCT LAUNDRY 581K(I)(S)(V) Overview The DEMA 581K SUDS Jr. Single Product Solid Laundry system has been updated and redesigned. It uses the proven DEMA Viking Bowl and removes
More informationReference Manual FM-200 Series
Flush Manifold A/P FOR LIQUID LAUNDRY SUPPLY SYSTEMS Reference Manual FM-200 Series Copyright 2004 Nova Controls, Inc. P/N 20-07941-00 Rev. C i P/N 20-07941-00 Rev. C ii P/N 20-07941-00 Rev. C 1 Description
More informationCrescent Flush Manifold FOR LIQUID LAUNDRY SUPPLY SYSTEMS
Crescent Flush Manifold FOR LIQUID LAUNDRY SUPPLY SYSTEMS Reference Manual FM-300 Series Copyright 2005 Nova Controls, Inc. P/N 20-08195-00 Rev. B i ii 1 Description Overview The FM-300 series Flush Manifold
More informationCaution! Pg. 1 of 5 I-932
Pg. 1 of 5 PFN26-SS BA25 QF1438 QFT38 CT38-15 DFP6 AW14 AW316 AHB14 AHB316 BA25 AP25 TANK 10 FOG-MAST DPN-10 DPG-10 DP-10 HBEL1238 PL10-B HBSS1212 W10 SSAXLE12 AXC12 SHW3 HB1438 STR14 SIDE VIEW Pg. 2 of
More informationPRO IV LIQUID DETERGENT & LIQUID RINSE DISPENSER INSTALLATION INSTRUCTIONS REVISION #5
PRO IV LIQUID DETERGENT & LIQUID RINSE DISPENSER INSTALLATION INSTRUCTIONS REVISION #5 STEP #1. MOUNTING 1. Choose a location where the unit is visible to the machine operator. 2. Locate the unit out of
More information23200 Navigator Dilution Control System 4 Button Model (NAV 4)
23200 Navigator Dilution Control System 4 Button Model (NAV 4) Overview The NAV 4 Chemical Dilution Control System accurately dilutes cleaning chemicals from cleaning concentrate product. It is a closed
More informationI Button Chemical Dispenser. Overview. Installation Instructions
4 Button Chemical Dispenser Overview The 4 Button Chemical Dispenser makes users more efficient, filling bottles and buckets with ease and quickness. Package Contains: Mounting Template Mounting hardware
More informationBIOACTIVE SOLUTIONS AC DRAIN STATION
BIOACTIVE SOLUTIONS AC DRAIN STATION 98488-00 Overview The BioActive Solutions Drain Station is a chemical dispenser with a programmable timer designed primarily for dispensing chemicals into drains. Its
More informationALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER IS NOT IN USE.
1060GAPRF With dilution selector 1060GAP OVERVIEW DEMA S MPD is a multiple product and dilution dispenser designed for use with SafeLink closed loop inserts. With its innovative patent pending QuickDock
More informationDrain Chief Plus Drain Maintenance/Odor Control Chemical Dispensing
Drain Chief Plus Drain Maintenance/Odor Control Chemical Dispensing Overview The VIKING Drain Chief Plus is a digital chemical dispenser that is designed to deliver chemicals for both drain and odor control.
More informationDEMA SQUIRT DRAIN UNIT
DEMA SQUIRT DRAIN UNIT Overview The Squirt is a chemical dispenser with a programmable timer designed primarily for dispensing chemicals into drains. Its most clear intended use is for drain applications
More information910 BHF OWNER S MANUAL. Pg. 1 of 9
OWNER S MANUAL Pg. 1 of 9 DFP6 TANK 10 HHPB1214 QF14P QFSEL14 QF1238 QFSEL38 PL10-CH QFA3838 DPN-10 DPG-10 DP-10 HBEL1238 H38B W10 SSAXLE12 AXC12 SHW3 FV2 Pg. 2 of 9 PSG-BRKT ICS-12V BC23-12V-A BC23-12V
More informationDEMA MIXRITE PROPORTIONING PUMP MODELS 574 & CL & 575CL FOR CORROSIVE LIQUID CHEMICALS INSTALLATION INSTRUCTION.
10% MixRite Pump I-871 Page 1 MODEL # INDUCTION RANGE%* TECHNICAL DATA TABLE Ability to turn off INDUCTION the chemical flow RANGE RATIO* while water is running OPERATING TEMPERATURE 574 3% to 10% 33/1
More informationALLSTAR DILUTION CONTROL SYSTEM MODEL 639AG-4-1ABC
MODEL 639AG-4-1ABC 1. PARTS: A. Blend Center assembly B. 5 pc. 1/4 ID x 8 ft. long vinyl supply tubing, with foot valve & ceramic weight C. 1 pc. 1/2 ID x 6 ft. long vinyl outlet tubing D. 2 pc. #8 pan
More informationCerto Chemical Dilution System
Certo Chemical Dilution System Overview The Certo Chemical Dilution System accurately dilutes chemical concentrates with water and dispenses the diluted mixture at either a high flow rate to fill buckets
More informationDEMA 257C / 257CV PRO BATTERY DRAIN CHIEF INSTALLATION & OPERATING INSTRUCTIONS
DEMA 257C / 257CV PRO BATTERY DRAIN CHIEF INSTALLATION & OPERATING INSTRUCTIONS Note This dispenser is designed for injecting drain and grease trap products in locations where an outlet isn t available.
More informationALWAYS FOLLOW ALL SAFETY PRECAUTIONS AS DIRECTED BY THE CLEANING CHEMICAL LABEL
Overview (Model # s 4-252- _ ) E2B2 Dispenser The E2B2 dispenser dilutes a concentrated EnvirOx product with water and dispenses the mixture with either a high flow rate (for filling buckets, scrubbers,
More informationIntended Use: Explanation of Signal Word Consequences
SAFETY INFORMATION & INSTRUCTION MANUAL Please read, understand, and follow all safety information contained in these instructions prior to the use of this device. Retain these instructions for future
More informationInstruction Book DeLaval Barrier Teat Dip Spray Extension Kit
Instruction Book DeLaval Barrier Teat Dip Spray Extension Kit - 0910 - Safety precautions DeLaval Barrier Teat Spray Exstention Kit Safety precautions Read carefully before using the product! For best
More informationPARTS LIST PONY 20 SCA
PARTS LIST PONY 20 SCA WIRING DIAGRAM PART NO. PART DESCRIPTION 4990601 GEARMOTOR - 120 VOLT 4990581 GEARMOTOR - 240 VOLT 4890391 VAC MOTOR - 115 VOLT 4891251 VAC MOTOR - 240 VOLT 4991321 BRUSH MOTOR -
More informationILCS EDGE System Installation Manual
ILCS EDGE System Installation Manual 0900885 Rev: A (12/06) Page 1 of 12 TABLE OF CONTENTS System Overview... 3 System Components... 3 System Diagram... 4 Pre-Installation... 5 Control Box & Power Supply
More informationFLUSH MANIFOLD REFERENCE MANUAL FOR LIQUID LAUNDRY SUPPLY SYSTEMS. FM-500 Series. P/N Rev. C
FLUSH MANIFOLD FOR LIQUID LAUNDRY SUPPLY SYSTEMS REFERENCE MANUAL FM-500 Series DESCRIPTION Figure 1.0a Description, Standard Flush Valve Water Inlet Pipe Tee Solenoid Valve Flow Switch Hose Barb (for
More informationM O D E L S EST- FL PARTS MANUAL Rev 1.00A
M O D E L S EST- FL PARTS MANUAL Rev 1.00A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com TABLE
More informationModel AM2 M40 Panel Installation, Operation, and Maintenance Manual
Model AM2 M40 Panel Installation, Operation, and Maintenance Manual RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and if found, report it immediately to the
More informationMODEL GLC PARTS MANUAL REV.1.02A
Owner s Manual Keep with machine for reference MODEL GLC PARTS MANUAL REV.1.02A CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-8 95-2 141 MODEL GL-C Parts MANUAL
More informationSAFETY INFORMATION & INSTRUCTION MANUAL
SAFETY INFORMATION & INSTRUCTION MANUAL Please read, understand, and follow all safety information contained in these instructions prior to the use of this device. Retain these instructions for future
More informationPACIFIC Recumbent Height-Adjustable Bath System Parts Breakdown and Assembly Manual
PACIFIC Recumbent Height-Adjustable Bath System 9700 Parts Breakdown and Assembly Manual Panel 390010-1 Tubs 390011-1 or 390022-1 390748 Revision H 4/1/2014 PENNER PATIENT CARE, INC Box 523 / 101 Grant
More informationMODEL CMA-180UC PARTS MANUAL Rev 1.19
MODEL CMA-180UC PARTS MANUAL Rev 1.19 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854- 6417 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS MODEL CMA-180UC 1. PARTS
More informationHSE M11 (AFTER SERIAL # )
8650 Enterprise Drive, Peosta IA 52068 563-556-7484 / Fax 563-556-1235 PARTS LIST FOR HSE-1002-0M11 (AFTER SERIAL #14999999) C US 201473 PUMP OIL GRADE: Mi-T-M #AW-4085-0016 CAPACITY: 11.2 oz FUEL NOZZLE:
More informationHeavy Duty Sprayer Owners Manual Model MS-O
Heavy Duty Sprayer Owners Manual Model MS-O Table of Contents Warranty 4 Warning 5 Assembly and Preparation 6 Operation 7 Cleaning and Storage 7 Standard Spray Gun & Parts List 8 Trigger Style Spray Gun
More informationS P R AY E R VA L V E S AND C O N T ROL S C AT A L OG
Q UA L I T Y VA LV E S A N D C O N T R O L S. TO D AY A N D TO M O R R O W. Texas Industrial Remcor, Inc. CATALOG NO. 33 The new RC2 control system: Ensures no potential leaks in the tractor cab when using
More informationMODEL CMA-180UC PARTS MANUAL Rev 1.19A
MODEL CMA-180UC PARTS MANUAL Rev 1.19A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS
More informationMODEL GL-X PARTS MANUAL
MODEL GL-X PARTS MANUAL Rev. 1.03A CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-8 95-2 141 www.cmadishmachines.com TABLE OF CONTENTS MODEL CMA-GL-X 1. PARTS MANUAL...3
More informationHIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL #: 091-9HP-220 INPUT:
INSTRUCTION MANUAL AUTO-PUMP HP 240 VAC HIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL #: 091-9HP-220 INPUT: 220-240 Vac, 50 Hz, 1.3 Amps 230 Vac, 60 Hz, 1.2 Amps File: IM_091-9HP-220-RevB2.indd Rev: B2 Revised
More informationUltraDose From Lyn Distributing
Automatic Dispensing System The UltraDose TM is a battery operated peristaltic pumping dispenser which runs automatically at preset times as programmed on an electronic timer/control mechanism. Model 1120
More informationCW ME1/3 CW ME1/3 CW ME3:
8650 Enterprise Drive, Peosta IA 52068 563-556-7484 / Fax 563-556-1235 PARTS LIST FOR CW-2405-4ME1/3 CW-3004-4ME1/3 CW-3006-4ME3 Motor Horsepower: CW-2405/3004-4ME1/3: 7.5HP CW-3006-4ME3: 15 HP Pump Oil
More informationAQUA-LAB Chemical Dispensing System. Operating Manual REV L
AQUA-LAB Chemical Dispensing System Operating Manual REV L Specifications 1. Operating water pressure: 200 psi (Factory set) 2. Pneumatics operating pressure: 100 psi (Factory set) 3. Maximum water source
More informationINSTRUCTIONS. Fc. -1,<" SERIES ST-261 REGULATING UNLOADER VALVE
INSTRUCTIONS Fc. -1,
More informationTHE JOB PRO PARTS LIST FOR JP-1002/1502-0ME1. Motor Horsepower: Nozzle Size: Copyright 2003, Mi-T-M Corporation
THE JOB PRO PARTS LIST FOR JP-1002/1502-0ME1 Motor Horsepower: jp-1002-0me1: jp-1502-0me1: Pump Oil Grade: Pump Oil Capacity: Nozzle Size: jp-1002-0me1: jp-1502-0me1: 1.5 H.P. 2.0 H.P. Mi-T-M Pump Oil
More informationF PRO. 12 Volt Electric Sprayer. Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14
F PRO SPRAYER by 12 Volt Electric Sprayer Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14 Table of Contents Feature and Benefits... 3 Specifications... 3 Complete Sprayer Diagram... 4 Complete Sprayer
More informationPARTS LIST FOR CM MEH. Copyright 2015, Mi-T-M Corporation
PARTS LIST FOR CM-1400-1MEH Motor Horsepower: Pump Oil Grade: Pump Oil Capacity: Nozzle Size: 1.5 H.P. Mi-T-M Pump Oil #AW-4085-0016 11.2 oz..95 mm 1 This Parts Listing has been compiled for your benefit.
More informationAEROMOTIVE Part # L Mustang Digital FMU INSTALLATION INSTRUCTIONS
AEROMOTIVE Part # 17113 4.6L Mustang Digital FMU INSTALLATION INSTRUCTIONS CAUTION: Installation of this product requires detailed knowledge of automotive systems and repair procedures. We recommend that
More informationELECTRIC SPRAYER CONTROL SYSTEM OWNERS MANUAL
-- AB00 Rev. 0 ELECTRIC SPRAYER CONTROL SYSTEM OWNERS MANUAL REPLACEMENT PARTS READ complete manual CAREFULLY BEFORE attempting operation. DEMCO Dethmers Mfg. Co. P.O. Box 0 0th Street Boyden, IA PH: ()
More information180 Lake Ave North Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER
180 Lake Ave North Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER Part Number PCD-E3-009B-MM Rev 2 Dec. 2012 Note: Do not return product to the distributor/dealer
More information8650 Enterprise Drive, Peosta IA / Fax
8650 Enterprise Drive, Peosta IA 52068 563-556-7484 / Fax 563-556-1235 PARTS LIST FOR HSE-1002-0M10 (AFTER SERIAL #15004675) HSE-1502-0M10 (AFTER SERIAL #15006316) HSE-2003-0M10 (AFTER SERIAL #15006268)
More information8650 Enterprise Drive, Peosta IA / Fax PARTS LIST FOR JP ME1/0ME3
8650 Enterprise Drive, Peosta IA 52068 563-556-7484 / Fax 563-556-1235 PARTS LIST FOR JP-3004-0ME1/0ME3 Motor Horsepower: 8 H.P. Pump Oil Grade: Mi-T-M Pump Oil #AW-4085-0016 Pump Oil Capacity: 18.5 oz.
More information8650 Enterprise Drive, Peosta IA / Fax PARTS LIST FOR JP ME1/0ME3
8650 Enterprise Drive, Peosta IA 52068 563-556-7484 / Fax 563-556-1235 PARTS LIST FOR JP-2503-0ME1/0ME3 Motor Horsepower: 6 H.P. Pump Oil Grade: Mi-T-M Pump Oil #AW-4085-0016 Pump Oil Capacity: 18.5 oz.
More informationM O D E L S E S T / E S T T A L L PARTS MANUAL Rev 1.08 C M A D I S H M A C H I N E S K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841
M O D E L S E S T / E S T T A L L PARTS MANUAL Rev 1.08 C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 54-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com
More informationMODEL L-1X & L-1X16 PARTS MANUAL
MODEL L-1X & L-1X16 PARTS MANUAL Rev 1.17A CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-8 95-2 141 TABLE OF CONTENTS MODEL CMA-L-1X & L-1X16 1. PARTS MANUAL...3
More informationInstallation & Operator s Manual
Installation & Operator s Manual LS5 Liquid Spray System 2 x 105 Gallon Tanks Installation Instructions 1. Position pump enclosure bracket (#3028485) 4 from rear gusset on driver side of hopper spreader,
More informationMODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM
MODEL NUMBER: 10003 MEDIUM DUTY ONBOARD AIR SYSTEM IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using
More informationDISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG BUNN-O-MATIC CORPORATION
8 4 0 0 1 BUNN Espress ES 2C DISCONTINUED VERSION Parts listed in this catalog may no longer be available. 12 0,5 1,5 CL 2 16 2,5 CAUTION HOT Liquid-Steam-Surfaces OFF ON ILLUSTRATED PARTS CATALOG Designs,
More informationMODEL L-1X & L-1X16 PARTS MANUAL. Rev 1.19A C M A D I S H M A C H I N E S K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841
MODEL L-1X & L-1X16 PARTS MANUAL Rev 1.19A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-854- 6417 F A X 7 1 4-8 9 5-2141 www.cmadishmachines.com TABLE
More information