N) manual. Register your instrument! Eppendorf Research plus. Operating manual

Size: px
Start display at page:

Download "N) manual. Register your instrument! Eppendorf Research plus. Operating manual"

Transcription

1 earch ual plus N) manual Register your instrument! Operating manual

2 Copyright 2018 Eppendorf AG, Germany. All rights reserved, including graphics and images. No part of this publication may be reproduced without the prior permission of the copyright owner. Eppendorf and the Eppendorf Brand Design are registered trademarks of Eppendorf AG, Germany. ept.i.p.s. and Research are registered trademarks of Eppendorf AG, Germany. Registered trademarks and protected trademarks are not marked in all cases with or in this manual. U.S. Patents are listed on U.S. Design Patents are listed on /082018

3 Table of contents 3 Table of contents 2 Safety Intended use Warnings for intended use Operating instructions Using this manual Danger symbols and danger levels Danger symbols Danger levels Symbols used Product description Delivery package Single-channel pipettes Multi-channel pipettes Features Pipette models Product overview Materials Warranty Operation Setting the volume Attaching the pipette tips Optimum immersion depths Forward pipetting Aspirating liquid Dispensing liquid Ejecting the pipette tip Reverse pipetting Aspirating liquid Dispensing liquid Ejecting the pipette tip Storing the pipette Troubleshooting Error search Control button Dispensing Pipette tip Tip cone

4 4 Table of contents 6 Maintenance Disassembling the single-channel pipette 1000 μl Removing the lower part Disassembling the lower part Disassembling the single-channel pipette 2.5 ml Removing the lower part Disassembling the lower part Assembling the single-channel pipette 1000 μl Assembling the single-channel pipette 2 ml Assembling the lower part Checking the function Replacing the protection filter 2 ml Replacing O-rings multi-channel lower part Removing the O-ring Mounting a new O-ring 100 μl and 300 μl Mounting a new O-ring 1200 μl Adjusting the pipette Cleaning Cleaning and disinfecting the pipette Cleaning and disinfecting the lower part Sterilizing the pipette with UV light Autoclaving the pipette Autoclaving Decontamination before shipment Lubricating the piston or cylinder Lubricating the piston Lubricating the cylinder Technical data Adjustable sub-steps single-channel pipettes Adjustable sub-steps multi-channel pipettes Ambient conditions Measurement deviations according to Eppendorf AG Single-channel pipettes with fixed volume setting Single-channel pipettes with variable volume setting Multi-channel pipettes with fixed cone spacing Test conditions Special tips for single-channel pipettes Ordering information Single-channel pipettes with fixed volume setting Single-channel pipettes with variable volume setting Multi-channel pipettes with fixed cone spacing mm cone spacing for 96-well plates

5 Operating instructions 5 1 Operating instructions 1.1 Using this manual Read this operating manual completely before using the device for the first time. Observe the instructions for use of the accessories where applicable. This operating manual is part of the product. Please keep it in a place that is easily accessible. Enclose this operating manual when transferring the device to third parties. The current version of the operating manual for all available languages can be found on our webpage Danger symbols and danger levels Danger symbols The safety instructions in this manual have the following danger symbols and danger levels: Biohazard Explosive substances Toxic substances Material damage Hazard point Danger levels DANGER WARNING CAUTION NOTICE Will lead to severe injuries or death. May lead to severe injuries or death. May lead to light to moderate injuries. May lead to material damage. 1.3 Symbols used Depiction Meaning 1. Actions in the specified order 2. Actions without a specified order List Text Display or software texts Additional information

6 6 Safety 2 Safety 2.1 Intended use The Research plus pipette is designed and constructed for low-contamination transfer of liquids. It is intended exclusively for use in research. This pipette is intended exclusively for indoor use, and for operation by trained and skilled personnel. 2.2 Warnings for intended use WARNING! Damage to health due to infectious liquids and pathogenic germs. When handling infectious liquids and pathogenic germs, observe the national regulations, the biosafety level of your laboratory, the material safety data sheets, and the manufacturer's application notes. Wear your personal protective equipment. For comprehensive regulations about handling germs or biological material of risk group II or higher, please refer to the "Laboratory Biosafety Manual" (source: World Health Organization, Laboratory Biosafety Manual, the current edition). WARNING! Damage to health due to toxic, radioactive or aggressive chemicals. Wear your personal protective equipment. Observe the national regulations for handling these substances. Observe the material safety data sheets and manufacturer's application notes. CAUTION! Danger to people due to grossly negligent use. Never point the opening of the device towards yourself or others. Only initiate liquid dispensing if it is safe to do so. For all dispensing tasks, make sure that you are not endangering yourself or anyone else. CAUTION! Poor safety due to incorrect accessories and spare parts. The use of accessories and spare parts other than those recommended by Eppendorf may impair the safety, functioning and precision of the device. Eppendorf cannot be held liable or accept any liability for damage resulting from the use of accessories and spare parts other than those recommended, or from the improper use of such equipment. Only use accessories and original spare parts recommended by Eppendorf.

7 Safety 7 NOTICE! Damage to the device due to missing pipette tips. Use the pipette with fitted pipette tips only. NOTICE! Carry-over, contamination and incorrect dispensing results due to the incorrect use of pipette tips. The pipette tips are for single use only. Prolonged use can have a negative impact on dispensing tasks. Only use the pipette tips once. Do not use autoclaved ep Dualfilter T.I.P.S. for dispensing. NOTICE! Incorrect dispensing volume with special liquids and due to temperature differences. Solutions with physical data very different to that of water or temperature differences between pipette, pipette tip and liquid may result in incorrect dispensing volumes. Avoid temperature differences between the pipette, pipette tip and liquid. NOTICE! Damage to device due to penetration of liquid. Only immerse the pipette tip in the liquid. Do not put the pipette down when the pipette tip is filled. The pipette itself may not come into contact with the liquid.

8 8 Product description 3 Product description 3.1 Delivery package Quantity Description 1 Research plus 1 Adjustment tool (Allen key with a blue handle) 5 Red adjustment seal 1 Pin (remove the safety plug) 1 Operating manual 1 Certificate Single-channel pipettes Quantity Description 1 Locking ring ( 1000 μl) 10 Protection filter (2.5 ml 10 ml) 1 Pipette wrench (2.5 ml 10 ml) Multi-channel pipettes Quantity Description 1 Multi-channel tool 100/300 (100 μl and 300 μl) 1 Multi-channel tool 1200 (1200 μl) 1 Unlocking tool (1200 μl) 2 Locking clip (8-channel lower part with 10 μl, 100 μl and 300 μl) 3 Locking clip (12-channel lower part with 10 μl, 100 μl and 300 μl)

9 Product description Features The Research plus pipette is a piston-stroke pipette for aspirating and dispensing liquids. The pipette operates according to the air cushion principle. A suitable pipette tip must be fitted prior to use. The dispensing and volume setting ring are controlled with the dispensing button. The pipette tips are ejected with the separate ejector. Depending on the model, volumes between 0.1 μl and 10 ml can be dispensed Pipette models Different variants are available: Single-channel pipettes with fixed volume setting Single-channel pipettes with variable volume setting Multi-channel pipettes with 8 or 12 channels with fixed cone spacing and variable volume setting

10 10 Product description 3.3 Product overview Abb. 3-1:Single-channel pipette and multi-channel pipette Fig. 3-1: Single-channel pipette and multi-channel pipette

11 Product description 11 1 Dispensing button 2 Volume setting ring 3 Ejector 4 Volume display 5 Single-channel upper part with nominal volume 6 Adjustment opening 7 Adjustment display 8 Labeling area 9 Single-channel lower part with nominal volume 10 Ejector sleeve 11 Tip cone 12 Pipette tip 13 Lever 14 Multi-channel lower part with nominal volume 15 Multi-channel upper part with nominal volume 16 Housing lid 17 Latch Opening the lower part

12 12 Product description 3.4 Materials NOTICE! Aggressive substances may damage components, consumables and accessories. Check the chemical resistance before using organic solvents or aggressive chemicals. Only use liquids whose vapors do not attack the materials used. The components of the pipette which can be accessed by the user are made of the following materials: Assembly Material External surfaces of the upper Improved polypropylene (PP) part Polycarbonate (PC) Polyetherimide (PEI) Foil Viewing window Polycarbonate (PC) Exterior and interior of lower parts Improved polypropylene (PP) Polyvinylidene fluoride (PVDF) Polyetherimide (PEI) Polyphenylene sulfide (PPS) Polyetheretherketone (PEEK) Polytetrafluoroethylene (PTFE) Ethylene propylene diene rubber (EPDM) Silicone Steel (stainless steel and spring steel) You can find information on the resistance to chemicals on our webpage Warranty In case of warranty claims, contact your local Eppendorf contractual partner. No warranty is given in the following cases: In the case of misuse. If unauthorized persons open the upper part. The following assemblies are excluded from the warranty: Wear parts

13 Operation 13 4 Operation 4.1 Setting the volume Setting a small volume Set the volume from a high to a low value. 1. Turn the volume setting ring clockwise. The set volume is shown on the volume display Setting a large volume Set the volume from a high to a low value. 1. Turn the volume setting ring counterclockwise. The set volume is shown on the volume display Reading the set volume The volume is shown on the volume display. The decimal place is under the hyphen. 1. Read the volume from top to bottom. Set volume: 80 μl.

14 14 Operation 4.2 Attaching the pipette tips The pipette tip can be attached by hand or mounted directly from a tip holder (tray) with the pipette. The pipette tips are single-use items. The control button and the trays are color-coded. The color marks the pipette size and the volume of the pipette tip (ept.i.p.s.). 1. Insert the tip cone into the pipette tip using light force. 4.3 Optimum immersion depths Volume Immersion depth 0.1 μl 1 μl 1 mm 1 μl 100 μl 2 3 mm 100 μl 1000 μl 2 4 mm 1 ml 10 ml 3 5 mm

15 Operation Forward pipetting Aspirating liquid Prerequisites The pipette tip has been attached. To ensure maximum precision and accuracy, we recommend initially wetting each new tip by aspirating and dispensing the liquid one to three times. 1. Press down the dispensing button to the first stop. 2. Immerse the pipette tip vertically in the liquid. 3. Maintain the immersion depth and let the dispensing button slide back slowly. Liquid is aspirated into the pipette tip. 4. Wait until the liquid has been aspirated. 5. Remove the pipette tip from the liquid. If necessary, wipe the pipette tip against the tube inner wall Dispensing liquid 1. Place the pipette tip on the tube inner wall at a steep angle. 2. Slowly press down the dispensing button to the first stop. The liquid is dispensed. 3. Wait until the flow of liquid stops. 4. Press down the dispensing button to the second stop. The pipette tip is completely emptied. 5. Hold down the dispensing button and wipe the pipette tip on the tube inner wall Ejecting the pipette tip Press the ejector. The pipette tip is ejected. 4.5 Reverse pipetting An additional volume (blow out) is aspirated when performing reverse pipetting. This can improve dispensing results for viscous or foaming liquids. Volume limits may occur when using filter tips.

16 16 Operation Aspirating liquid 1. Press down the dispensing button to the second stop. 2. Immerse the pipette tip vertically in the liquid. 3. Maintain the immersion depth and let the dispensing button slide back slowly. Liquid is aspirated into the pipette tip. 4. Wait until the liquid has been aspirated. 5. Remove the pipette tip from the liquid. If necessary, wipe the pipette tip against the tube inner wall Dispensing liquid 1. Place the pipette tip on the tube inner wall at a steep angle. 2. Slowly press down the dispensing button to the first stop. The liquid is dispensed. 3. Wait until the flow of liquid stops. 4. Hold down the dispensing button and wipe the pipette tip on the tube inner wall. Residual liquid remains in the pipette tip. During dispensing, the additional volume (blow out) does not belong to the dispensing volume Ejecting the pipette tip 1. Press down the dispensing button to the second stop. The residual liquid is dispensed. The residual liquid can be discarded. 2. Press the ejector. The pipette tip is ejected. 4.6 Storing the pipette The pipette can be stored in a pipette carousel, a wall mount or in horizontal position.

17 Troubleshooting 17 5 Troubleshooting 5.1 Error search Problem Cause Solution The adjustment seal has been removed; the adjustment display has been changed Control button Dispensing The pipette has been adjusted for a different liquid. Problem Cause Solution The dispensing button jams and does not move smoothly. The piston is dirty. The seal is dirty. The seal is defective. The pipette is blocked. Adjust the pipette for the liquid used. Clean the lower part. Replace the protection filter (2.5 ml 10 ml). Problem Cause Solution Liquid is dripping from Pipette tip is loose. Firmly attach the pipette the tip and/or the tip dispensed volume is Deactivate the incorrect. spring-loaded action. Use ept.i.p.s. pipette tips. For 2.5 ml, 5 ml and 10 ml ep Dualfilter T.I.P.S. pipette tips, work without a protection filter in the pipette. Liquid with high vapor pressure and/or different density. Pipetting was too quick. The tip is withdrawn from the liquid too quickly. Liquid aspirated with blow-out and dispensed with blow-out. Wet the tip several times and adjust the pipette for the liquid used. Move the dispensing button slowly. Withdraw the tip slowly from the liquid with a time delay (approx. 3 seconds). Repeat dispensing correctly.

18 18 Troubleshooting Problem Cause Solution Pipette tip Tip cone The piston is contaminated. The tip cone is damaged. The O-rings of the tip cones are damaged. Clean and grease the piston. Replace the lower part or channel. Replace the O-rings (100 μl, 300 μl and 1200 μl multi-channel). Problem Cause Solution Pipette tip is loose. The pipette tip is not compatible. Use ept.i.p.s. pipette tips. Use a suitable size. Higher attachment forces are required. Firmly attach the pipette tip. Deactivate the spring-loaded action. Problem Cause Solution No spring-loaded action of the tip cone. The spring-loaded action is blocked. Use of a 2.5 ml-, 5 ml-,10 ml or 1200 μl pipette. Remove the locking ring (single-channel). Remove the locking clip (multi-channel). The tip cone of these sizes does not have spring-loading action. To prevent dispensing errors, regularly check the precision and accuracy of the pipette. The gravimetric test and the conversion of the measured values for the volume are described in the document Standard operating procedure for manual dispensing systems". The document is available on the webpage

19 Maintenance 19 6 Maintenance 6.1 Disassembling the single-channel pipette 1000 μl Abb. 6-1:Single-channel lower part 1000 μl Fig. 6-1: Single-channel lower part 1000 μl 1 Piston mount 2 Piston 3 Piston spring 4 Double coil 5 Cylinder (internal) Removing the lower part 1. Press the dispensing button completely down and hold. 2. Remove the ejector sleeve and release the dispensing button. 3. Push the ring PUSH UP TO RELEASE upward until the lower part is detached. 4. Take out the lower part.

20 20 Maintenance Disassembling the lower part Prerequisites The ejector sleeve has been removed. The lower part has been removed from the upper part. 1. Slightly squeeze the stop pins at the piston mount. 2. Remove the piston mount. 3. Remove the piston spring and the piston. 4. Remove the piston from the piston spring (not possible for pipettes with blue dispensing button). 6.2 Disassembling the single-channel pipette 2.5 ml Abb. 6-2:Single-channel lower part 2.5 ml Fig. 6-2: Single-channel lower part 2.5 ml 1 Piston mount 2 Piston spring 3 Piston guide 4 Piston 5 Cylinder with tip cone 6 Filter sleeve with protection filter

21 Maintenance Removing the lower part Unscrew the ejector sleeve Keep the dispensing button fully pressed. 3. Turn the lower part approximately 30 to the right. The lower part is released from the upper part Disassembling the lower part Prerequisites The lower part is removed. 1. Fit the pipette wrench onto the lower part. 2. Hold the cylinder and unscrew it from the lower part.

22 22 Maintenance 6.3 Assembling the single-channel pipette 1000 μl 1. Insert the piston spring. If using piston springs with double coil, this must point down. 2. Carefully insert the piston into the cylinder from the top. 3. Compress the piston spring with piston and hold. 4. Squeeze the stop pins at the piston mount and attach them. 5. Press on the piston from above and check for free movement. The piston must be able to move freely without resistance. 6. Insert the lower part into the upper part until it engages. 7. Fit the ejector sleeve. 6.4 Assembling the single-channel pipette 2 ml Assembling the lower part 1. Insert the piston into the piston guide. 2. Insert the piston spring into the piston guide. 3. Attach the piston mount and press the piston spring into the piston guide. 4. Turn the piston mount by 90 and let it engage. 5. Insert the lower part into the upper part until it engages. 6. Attach and tighten the ejector sleeve Checking the function This inspection ensures that the pipette has been assembled correctly. Carry out a gravimetric test of the systematic and random errors.

23 Maintenance Replacing the protection filter 2 ml The protection filter in the tip cone must be replaced after every contact with liquids. 1. Place a pipette wrench with the appropriate opening onto the filter sleeve. 2. Pull out the filter sleeve. 3. Use a pipette tip to push out the filter. 4. Clean the filter sleeve. 5. Insert a new protection filter into the filter sleeve. 6. Insert the filter sleeve in the tip cone.

24 24 Maintenance 6.6 Replacing O-rings multi-channel lower part Replace worn or damaged O-rings on multi-channel lower parts. Applies to multi-channel lower parts: 100 μl 300 μl 1200 μl Removing the O-ring Prerequisites O-ring tool (included in the delivery package) 1. Push the opening of the O-ring tool against the tip cone. 2. Supporting the O-ring tool with your thumb, push it against the tip cone. The O-ring is cut at one location. 3. Remove the O-ring tool and O-ring Mounting a new O-ring 100 μl and 300 μl Prerequisites Mounting aid (shortened pipette tip) 1. Fit the installation aid on the tip cone. 2. Push the O-ring over the installation aid and onto the tip cone. The O-ring must be positioned in the groove in the tip cone. 3. Remove the installation aid 4. Attach the pipette tip and check it is seated correctly. The pipette tip must be firmly seated on the tip cone Mounting a new O-ring 1200 μl 1. Push the O-ring onto the tip cone. The O-ring must be positioned in the groove in the tip cone. 2. Attach the pipette tip and check it is seated correctly. The pipette tip must be firmly seated on the tip cone.

25 Maintenance Adjusting the pipette The execution of changes to the user adjustment and factory adjustment is described on our website Cleaning NOTICE! Damage to device from unsuitable cleaning fluids or sharp or pointed objects. Unsuitable cleaning agents may damage the device. Do not use corrosive cleaning agents, strong solvents or abrasive polishes. Check the compatibility with the materials used. Please note the information on chemical resistance. Do not clean the device with acetone or organic solvents with a similar effect. Do not use sharp or pointed objects to clean the device. NOTICE! Damage to device due to penetration of liquid. Only immerse the pipette tip in the liquid. Do not put the pipette down when the pipette tip is filled. The pipette itself may not come into contact with the liquid Cleaning and disinfecting the pipette All single and multi-channel lower parts are wear parts. Clean them after contamination, use of aggressive chemicals and/or heavy stress. If the lower parts are worn or damaged, replace these parts. 1. Moisten a cloth with a cleaning agent and a decontamination agent. 2. Remove external contamination. 3. Moisten a new cloth with water. 4. Wipe down the housing.

26 26 Maintenance Cleaning and disinfecting the lower part Prerequisites Heavy contamination caused by ingress of liquid must be removed. Lower part has been removed and disassembled. 1. Remove piston grease. 2. Rinse the lower part with cleaning agent or decontamination agent or let it soak. Observe the contact time recommended by the manufacturer. 3. Thoroughly rinse the lower part with demineralized water. 4. Let it dry. 5. Lubricate the piston or cylinder. See instructions for use "Grease for pipettes". 6. Assemble the lower part Sterilizing the pipette with UV light The pipette can be sterilized with UV light at 254 nm. 6.9 Autoclaving the pipette NOTICE! Damage to device due to incorrect handling. Do not use any additional disinfectants, decontamination agents or sodium hypochlorite during autoclaving or UV irradiation Autoclaving Autoclave the filter sleeve and the protection filter separately. Upper part and lower part can be autoclaved in assembled state. The lower part does not have to be disassembled. Prerequisites The pipette has been cleaned. Any residual cleaning agent has been removed. The protection filter has been removed. 1. Autoclave the pipette at 121 C and 1 bar overpressure for 20 minutes. 2. Cool the pipette to ambient temperature and let it dry. For maximum precision and accuracy, a gravimetric test is recommended after disassembly and autoclaving. The pistons do not have to be relubricated and adjusted after autoclaving.

27 Maintenance Decontamination before shipment CAUTION! Use of a contaminated device may result in personal injuries and damage to the device. Clean and decontaminate the device in accordance with the cleaning instructions before shipping or storage. Hazardous substances are: solutions presenting a hazard to health potentially infectious agents organic solvents and reagents radioactive substances proteins presenting a hazard to health DNA 1. Please note the information in the document "Decontamination certificate for product returns". It is available as PDF document on our website 2. Enter the serial number of the device in the decontamination certificate. 3. Enclose the completed decontamination certificate for returned goods with the device. 4. Send the device to Eppendorf AG or an authorized service center.

28 28 Maintenance 6.11 Lubricating the piston or cylinder The piston or the cylinder in the lower part of the pipette must be relubricated after cleaning or after decontamination. The special grease can be ordered as an accessory. The ordering information can be found on our webpage Cotton swab 2 Piston 20 μl 3 Running surface 4 Cylinder 5 Lower part > 20 μl Lubricating the piston Prerequisites For volumes 20 μl. Lower part is disassembled. 1. Place a small amount of grease on the cotton swab. 2. Apply a thin film of grease to the running surface of the piston. The lower part can now be reassembled Lubricating the cylinder Prerequisites For volumes > 20 μl. Lower part is disassembled. 1. Place a small amount of grease on the cotton swab. 2. Apply a thin film of grease to the inner wall of the piston. The lower part can now be reassembled.

29 Technical data 29 7 Technical data 7.1 Adjustable sub-steps single-channel pipettes Model 7.2 Adjustable sub-steps multi-channel pipettes 7.3 Ambient conditions Increment 0.1 μl 2.5 μl μl 0.5 μl 10 μl 0.01 μl 2 μl 20 μl 0.02 μl 10 μl 100 μl 0.1 μl 20 μl 200 μl 0.2 μl 30 μl 300 μl 0.2 μl 100 μl 1000 μl 1 μl 0.25 ml 2.5 ml 2 μl 0.5 ml 5 ml ml 1 ml 10 ml 0.01 ml Model Increment 0.5 μl 10 μl 0.01 μl 10 μl 100 μl 0.1 μl 30 μl 300 μl 0.2 μl 120 μl 1200 μl 1 μl Storage without transport package Temperature range Relative humidity -5 C 45 C 10 % 95 % Operating conditions 5 C 40 C 10 % 95 %

30 30 Measurement deviations according to Eppendorf AG 8 Measurement deviations according to Eppendorf AG 8.1 Single-channel pipettes with fixed volume setting Model 10 μl medium gray 20 μl light gray 10 μl yellow 20 μl yellow 25 μl yellow 50 μl yellow 100 μl yellow 200 μl yellow 200 μl blue 250 μl blue 500 μl blue 1000 μl blue Test tip ept.i.p.s. 0.1 μl 20 μl medium gray 40 mm 0.5 μl 20 μl L light gray 46 mm 2 μl 200 μl yellow 53 mm 50 μl 1000 μl blue 71 mm Error of measurement systematic random ± % ± μl ± % ± μl

31 Measurement deviations according to Eppendorf AG Single-channel pipettes with variable volume setting Model Test tip Testing Error of measurement ept.i.p.s. volume systematic random ± % ± μl ± % ± μl 0.1 μl 2.5 μl 0.1 μl 10 μl 0.1 μl dark gray dark gray 0.25 μl mm 1.25 μl μl μl 10 μl 0.1 μl 20 μl 0.5 μl medium gray medium gray 1 μl mm 5 μl μl μl 20 μl 0.5 μl 20 μl L 2 μl light gray light gray 10 μl mm 20 μl μl 20 μl 2 μl 200 μl 2 μl yellow yellow 10 μl mm 20 μl μl 100 μl 2 μl 200 μl 10 μl yellow yellow 50 μl mm 100 μl μl 200 μl 2 μl 200 μl 20 μl yellow yellow 100 μl mm 200 μl μl 300 μl 20 μl 300 μl 30 μl orange orange 150 μl mm 300 μl μl 1000 μl 50 μl 1000 μl 100 μl blue blue 500 μl mm 1000 μl ml 2.5 ml 0.25 ml 2.5 ml 0.25 ml red red 1.25 ml mm 2.5 ml

32 32 Measurement deviations according to Eppendorf AG Model 0.5 ml 5 ml violet 1 ml 10 ml turquoise Test tip ept.i.p.s. 0.1 ml 5 ml violet 120 mm 1 ml 10 ml turquoise 165 mm Testing Error of measurement volume systematic random ± % ± μl ± % ± μl 0.5 ml ml ml ml ml ml Multi-channel pipettes with fixed cone spacing Model Test tip Testing Error of measurement ept.i.p.s. volume systematic random ± % ± μl ± % ± μl 0.5 μl 10 μl 0.1 μl 20 μl 0.5 μl medium gray medium gray 1 μl /12 channel 40 mm 5 μl μl μl 100 μl 2 μl 200 μl 10 μl yellow yellow 50 μl /12 channel 53 mm 100 μl μl 300 μl 20 μl 300 μl 30 μl orange orange 150 μl /12 channel 55 mm 300 μl μl 1200 μl 50 μl 1250 μl 120 μl green green 600 μl /12 channel 76 mm 1200 μl

33 Measurement deviations according to Eppendorf AG Test conditions Test conditions and test evaluation in compliance with ISO 8655, Part 6. Tested using a standardized analytical scale with evaporation protection. The three largest testing volumes per tip (10 %, 50 %, 100 % of the nominal volume) correspond to the specifications in accordance with ISO 8655, Part 2 or Part 5. The test is to be carried out with these three testing volumes for testing of the systematic and random error in compliance with the standard. The smallest adjustable volume serves to provide additional information. Number of determinations per volume: 10 Water according to ISO 3696 Inspection at 20 C 27 C Maximum temperature variation during measurement ±0.5 C Dispensing onto the tube inner wall 8.5 Special tips for single-channel pipettes Model Special tip Testing ept.i.p.s. Long volume 0.5 ml 5 ml violet 1 ml 10 ml turquoise 0.1 ml 5 ml L violet 175 mm 1 ml 10 ml L turquoise 243 mm Error of measurement systematic random ± % ± μl ± % ± μl 0.5 ml ml ml ml ml ml

34 34 Ordering information 9 Ordering information 9.1 Single-channel pipettes with fixed volume setting Order no. Description (International) Eppendorf Research plus single-channel, fixed μl, medium gray μl, yellow μl, light gray μl, yellow μl, yellow μl, yellow μl, yellow μl, yellow μl, blue μl, blue μl, blue μl, blue 9.2 Single-channel pipettes with variable volume setting Order no. Description (International) Eppendorf Research plus Single-channel, variable μl, dark gray μl, medium gray μl, light gray μl, yellow μl, yellow μl, yellow μl, orange μl, blue ml, red ml, violet ml, turquoise

35 Ordering information Multi-channel pipettes with fixed cone spacing mm cone spacing for 96-well plates Order no. Description (International) Eppendorf Research plus 8-channel, variable μl, medium gray μl, yellow μl, orange μl, green Eppendorf Research plus 12-channel, variable μl, medium gray μl, yellow μl, orange μl, green The ordering information can be found on our website

36 36 Ordering information

37

38 Evaluate Your Manual Give us your feedback. Your local distributor: Eppendorf AG Barkhausenweg Hamburg Germany eppendorf@eppendorf.com

N) manual. Register your instrument! Eppendorf Reference 2. Operating manual

N) manual. Register your instrument!  Eppendorf Reference 2. Operating manual erence ual 2 N) manual Register your instrument! www.eppendorf.com/myeppendorf Operating manual Copyright 2016 Eppendorf AG, Germany. All rights reserved, including graphics and images. No part of this

More information

Register your instrument! Eppendorf Reference 2. Operating manual

Register your instrument!  Eppendorf Reference 2. Operating manual Register your instrument! www.eppendorf.com/myeppendorf Operating manual Operating Eppendorf see on Fig. Tab. p. p. manual Reference 2 Copyright 2016 Eppendorf AG, Germany. All rights reserved, including

More information

N) manual. Register your instrument! Eppendorf Research plus. Operating manual

N) manual. Register your instrument!  Eppendorf Research plus. Operating manual earch ual plus N) manual Register your instrument! www.eppendorf.com/myeppendorf Operating manual Copyright 2017 Eppendorf AG, Germany. All rights reserved, including graphics and images. No part of this

More information

N) manual. Register your instrument! Eppendorf Research plus. Operating manual

N) manual. Register your instrument!   Eppendorf Research plus. Operating manual search ual plus N) manual Register your instrument! www.eppendorf.com/myeppendorf Operating manual Copyright 2013 Eppendorf AG, Hamburg. No part of this publication may be reproduced without the prior

More information

4 ual Repeater M4. N) manual. Register your instrument! Multipette M4 Repeater M4. Operating manual

4 ual Repeater M4. N) manual. Register your instrument!   Multipette M4 Repeater M4. Operating manual 4 ual Repeater M4 N) manual Register your instrument! www.eppendorf.com/myeppendorf Operating manual Copyright 2018 Eppendorf AG, Germany. All rights reserved, including graphics and images. No part of

More information

Register your instrument! HeatSealer S100. Operating manual

Register your instrument!   HeatSealer S100. Operating manual 00N) manual Register your instrument! www.eppendorf.com/myeppendorf Operating manual Copyright 2015 Eppendorf AG, Germany. All rights reserved, including graphics and images. No part of this publication

More information

Register your instrument! Easypet 3. Operating manual

Register your instrument!   Easypet 3. Operating manual N) manual Register your instrument! www.eppendorf.com/myeppendorf Operating manual Copyright 2017 Eppendorf AG, Germany. All rights reserved, including graphics and images. No part of this publication

More information

Register your instrument! Easypet 3. Operating manual

Register your instrument!   Easypet 3. Operating manual Register your instrument! www.eppendorf.com/myeppendorf Operating manual Copyright 2016 Eppendorf AG, Germany. All rights reserved, including graphics and images. No part of this publication may be reproduced

More information

Register your instrument! Easypet 3. Operating manual

Register your instrument!   Easypet 3. Operating manual N) manual Register your instrument! www.eppendorf.com/myeppendorf Operating manual Copyright 2014 Eppendorf AG, Hamburg. All rights reserved, including graphics and images. No part of this publication

More information

3/E3x ual Repeater E3/E3x

3/E3x ual Repeater E3/E3x 3/E3x ual Repeater E3/E3x N) manual Register your instrument! www.eppendorf.com/myeppendorf Multipette E3/E3x Repeater E3/E3x Operating manual Copyright 2016 Eppendorf AG, Germany. All rights reserved,

More information

3/E3x ual Repeater E3/E3x

3/E3x ual Repeater E3/E3x 3/E3x ual Repeater E3/E3x N) manual Register your instrument! www.eppendorf.com/myeppendorf Multipette E3/E3x Repeater E3/E3x Operating manual Copyright 2017 Eppendorf AG, Germany. All rights reserved,

More information

Easypet 3. Operating manual

Easypet 3. Operating manual Easypet see on Fig. Tab. p. p. 3manual Operating manual Easypet 3 Operating manual 4430 900.019 Copyright 2012 Eppendorf AG, Hamburg. No part of this publication may be reproduced without the prior permission

More information

LIQUID HANDLING TECHNOLOGY. User Manual Bedienungsanleitung

LIQUID HANDLING TECHNOLOGY. User Manual Bedienungsanleitung LIQUID HANDLING TECHNOLOGY User Manual Bedienungsanleitung EC Declaration of Conformity USA Scientific certifies that 7166-0010 ErgoOne FAST has been manufactured and inspected in accordance with the following

More information

Multipette /Repeater (X)stream. Operating manual

Multipette /Repeater (X)stream. Operating manual Multipette /Repeater (X)stream 4986 900.115 Copyright 2008 Eppendorf AG, Hamburg. No part of this publication may be reproduced without the prior permission of the copyright owner. Registered trademarks

More information

CappController Pipette Controller. Operation Manual Version: 1.2.

CappController Pipette Controller. Operation Manual Version: 1.2. CappController Pipette Controller Operation Manual Version: 1.2 www.capp.dk Table of Content 1. Safety Precautions... 1 2. General Description... 2 3. Getting Started... 3 3.1. Recharging the Battery...

More information

Operation Manual. Pipette Aid. Concorde Liquid Handling Equipment. *This instrument is intended for laboratory use only.

Operation Manual. Pipette Aid. Concorde Liquid Handling Equipment. *This instrument is intended for laboratory use only. Concorde Liquid Handling Equipment Pipette Aid Operation Manual Cat. no. R14-PANAID *This instrument is intended for laboratory use only http://www.recenttec.com E-mail : support@recenttec.com Version

More information

CLASSIC. User s Guide. Do not lubricate this pipette. The use of lubricant cancels the warranty of this pipette. NOTICE

CLASSIC. User s Guide. Do not lubricate this pipette. The use of lubricant cancels the warranty of this pipette. NOTICE CLASSIC User s Guide EN NOTICE Do not lubricate this pipette. The use of lubricant cancels the warranty of this pipette. TABLE OF CONTENTS INTRODUCTION 3 Parts Checklist 3 GLP Features 3 Description 4

More information

Thermo Scientific Matrix Manual Pipette User Manual

Thermo Scientific Matrix Manual Pipette User Manual Thermo Scientific Matrix Manual Pipette User Manual Thermo Scientific Matrix Manual Pipette User Manual Trademarks and Copyright 2007 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are

More information

BlueSwan Pipette Controller

BlueSwan Pipette Controller BlueSwan Pipette Controller BSST-0100 Operation Manual Ver. 1.0 Copyright 2016 Blue-Ray Biotech Corp. All Rights Reserved. Table of Contents 1. Safety Precautions... 1 2. General Description... 2 2.1

More information

TABLE OF CONTENTS INTRODUCTION. Chapter 1. Parts Check List INTRODUCTION TABLE OF CONTENTS NOTICE INTRODUCTION 3

TABLE OF CONTENTS INTRODUCTION. Chapter 1. Parts Check List INTRODUCTION TABLE OF CONTENTS NOTICE INTRODUCTION 3 User s Guide EN G TABLE OF CONTENTS TABLE OF CONTENTS INTRODUCTION 3 Parts CheckList 3 GLP Features 4 Description Specifications 6 SETTING THE VOLUME 8 PIPETTING 9 Fit the Tips 9 Pre-rinse the Tips 0 Aspirate

More information

Repeater Plus Pipette. Instruction Manual Mode d emploi Manual de Instrucciones

Repeater Plus Pipette. Instruction Manual Mode d emploi Manual de Instrucciones 4 Repeater Plus Pipette Instruction Manual Mode d emploi Manual de Instrucciones Repeater Plus Pipette Instruction Manual.......................1 Mode d'emploi.........................13 Manual de Instrucciones.................25

More information

User Manual dpette+ Electronic Pipette 2016-ver.1

User Manual dpette+ Electronic Pipette 2016-ver.1 User Manual dpette+ Electronic Pipette 2016-ver.1 CONTENTS 1. Product Overview...- 1-2. Parts Description...- 3-3. Display... - 5-4. Operation...- 6-5. dpette+ setup... - 14-6. Storage... - 18-7. Care

More information

User s Manual. Pipette Controller for liquid handling. Thank you very much for purchasing Pipette Mate NEO.

User s Manual. Pipette Controller for liquid handling. Thank you very much for purchasing Pipette Mate NEO. Pipette Controller for liquid handling User s Manual Thank you very much for purchasing Pipette Mate NEO. Please read this manual carefully before using. Always Pursuing Originality Since 1944 Features

More information

Eppendorf Repeater Pro Instruction Manual Manual de Instrucciones

Eppendorf Repeater Pro Instruction Manual Manual de Instrucciones Eppendorf Repeater Pro Instruction Manual Manual de Instrucciones Technical Data / Datos técnicos Technical Data / Datos técnicos See chapter 4 / ver apartado 4 Systematic error/ Error sostemàtico (Inaccuracy/Incorreción)

More information

Liquid Handling Easy Handling! Transferpette. electronic. Gebrauchsanleitung Operating Manual Mode d'emploi Instrucciones de manejo

Liquid Handling Easy Handling! Transferpette. electronic. Gebrauchsanleitung Operating Manual Mode d'emploi Instrucciones de manejo Liquid Handling Easy Handling! Transferpette electronic F I R S T C L A S S B R A N D 3 33 63 93 Gebrauchsanleitung Operating Manual Mode d'emploi Instrucciones de manejo Table of Contents Safety Instructions

More information

Register your instrument! MiniSpin /MiniSpin plus. Operating manual

Register your instrument!  MiniSpin /MiniSpin plus. Operating manual Register your instrument! www.eppendorf.com/myeppendorf Operating manual Operating MiniSpin /MiniSpin see on Fig. Tab. p. p. manual plus Copyright 2015 Eppendorf AG, Germany. All rights reserved, including

More information

Never charge the batteries with a charger other than that supplied by the manufacturer.

Never charge the batteries with a charger other than that supplied by the manufacturer. INTRODUCTION The Diamond SeroLogic portable pipette controller is a rechargeable electronic pipetting aid designed for use with glass or plastic serological pipettes in the 0.1 to 100mL volume range. The

More information

SofTouch Electronic Precision Pipette Instruction Manual

SofTouch Electronic Precision Pipette Instruction Manual SofTouch Electronic Precision Pipette Instruction Manual CONTENTS 1.HAMILTON SOFTOUCH ELECTRONIC PIPETTE... 2 1.1. SofTouch Single Channel Electronic Pipettes... 2 1.2. SofTouch Multi-Channel Electronic

More information

Ultra. Pipetman. continuously adjustable digital microliter pipettes. 8 pipettes for volume ranges from 0.1 µl to 10 ml

Ultra. Pipetman. continuously adjustable digital microliter pipettes. 8 pipettes for volume ranges from 0.1 µl to 10 ml Pipetman continuously adjustable digital microliter pipettes Ultra 8 pipettes for volume ranges from 0.1 µl to 10 ml U-2 U-10 U-20 U-100 U-200 U-1000 U-5000 U-10ML Pipetman Ultra U-200 shown Contents Description...1

More information

Operation Manual BOTTLE TOP DISPENSER

Operation Manual BOTTLE TOP DISPENSER Operation Manual BOTTLE TOP DISPENSER TABLE OF CONTENTS Page No. Intended Use Of The Instrument 1 Safety Instructions 1 Functions and Limitations of Use 2 Operating Exclusions 3 Storage Conditions 3 Chemical

More information

Liquid Handling Easy Handling! Transferpette -8/-12. electronic. Gebrauchsanleitung Operating Manual Mode d'emploi Instrucciones de manejo

Liquid Handling Easy Handling! Transferpette -8/-12. electronic. Gebrauchsanleitung Operating Manual Mode d'emploi Instrucciones de manejo Liquid Handling Easy Handling! Transferpette -8/-12 electronic F I R S T C L A S S B R A N D 3 35 67 99 Gebrauchsanleitung Operating Manual Mode d'emploi Instrucciones de manejo Table of Contents Page

More information

JADE Bottle Top Dispenser

JADE Bottle Top Dispenser Accrediting Certifying Bodies S C B A (E) ASCB(E) UK ISO 13485 JADE Bottle Top Dispenser Re-Circulation Valve Operation Manual TABLE OF CONTENTS Page No. Intended Use Of The Instrument 1 Safety Instruction

More information

Single and 8-channel Electronic Pipettes. Operation Manual Version: 2.9

Single and 8-channel Electronic Pipettes. Operation Manual Version: 2.9 Single and 8-channel Electronic Pipettes Operation Manual Version: 2.9 Table of Contents 1. Safety Precautions...1 1.1. Operation Safety Precautions...1 1.2. Battery Safety...1 2. General Description...3

More information

Nichipet EX Plus II. User s Manual. Autoclavable & UV resistant. Digital micro pipette for liquid handling

Nichipet EX Plus II. User s Manual. Autoclavable & UV resistant. Digital micro pipette for liquid handling Autoclavable & UV resistant Nichipet EX Plus II Digital micro pipette for liquid handling User s Manual In Vitro Medical Diagnostic Devices (98/79/EC) Annex III self-declared ISO 8655 STANDARD CERTIFIED

More information

Prospenser. User Manual Mode d emploi Bedienungsanleitung Manual Usuario. For capacities of 2.5 ml 5 ml 10 ml 30 ml and 50 ml

Prospenser. User Manual Mode d emploi Bedienungsanleitung Manual Usuario. For capacities of 2.5 ml 5 ml 10 ml 30 ml and 50 ml Prospenser User Manual Mode d emploi Bedienungsanleitung Manual Usuario For capacities of 2.5 ml 5 ml 10 ml 30 ml and 50 ml Prospenser User Manual...1 Mode d emploi... 11 Bedienungsanleitung... 21 Manual

More information

Operator s Guide for Mechanical Volume-Set Pipettes (Ovation M)

Operator s Guide for Mechanical Volume-Set Pipettes (Ovation M) Operator s Guide for Mechanical Volume-Set Pipettes (Ovation M) L070-0001-001 Rev. B TABLE OF CONTENTS Introduction Product Description & Specifications 1-1 Pipette Components 1-2 BioNatural Pipetting

More information

Eppendorf Easypet. Operating manual

Eppendorf Easypet. Operating manual Eppendorf Easypet Operating manual 4421 900.090 Copyright 2010 Eppendorf AG, Hamburg. No part of this publication may be reproduced without the prior permission of the copyright owner. eppendorf and Eppendorf

More information

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual Copyright Copyright 2014 Eppendorf AG, Germany. No part of this publication may be reproduced without the prior permission

More information

Tissue Master. User Manual

Tissue Master. User Manual Tissue Master User Manual This page left blank intentionally This manual is a guide for the use of the Omni International Tissue Master and accessories. Data herein has been verified and validated. It

More information

Premium Design - Premium Performance - Premium Quality

Premium Design - Premium Performance - Premium Quality WITOPET premium NEW Premium Design - Premium Performance - Premium Quality Looking for the latest pipetting innovation at an attractive price? WITOPET premium is just the right pipette for you. The ergonomic

More information

Pipette Controllers OPERATOR INSTRUCTIONS

Pipette Controllers OPERATOR INSTRUCTIONS Pipette Controllers OPERATOR INSTRUCTIONS Introduction GlassMaster has been carefully designed and manufactured as a lightweight, cordless pipetting aid for use with all plastic or glass pipettes from

More information

PIPETMAN ultra. EN ENGLISH User's Guide

PIPETMAN ultra. EN ENGLISH User's Guide PIPETMAN ultra EN ENGLISH User's Guide PIPETMAN ultra Contents Page 1 - INTRODUCTION 2 2 - PARTS CHECK LIST 3 3 - DESCRIPTION 4 4 - SWITCHING ON 5 5 - VOLUME INDICATOR - LCD WINDOW 6 6 - SETTING THE VOLUME

More information

Multichannel ENGLISH

Multichannel ENGLISH PIPETMAN Ultra Multichannel ENGLISH PIPETMAN Ultra Multichannel CONTENTS page 1 - INTRODUCTION 2 2 - PARTS CHECK LIST 3 3 - DESCRIPTION 4 4 - SWITCHING ON 5 5 - VOLUME INDICATOR - LCD WINDOW 6 6 - SETTING

More information

Userts Manual. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC) Annex III self-declared ISO 8655 STANDARD

Userts Manual. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC) Annex III self-declared ISO 8655 STANDARD Autoclavable & UV Resistant Digital micro pipette for liquid handling Userts Manual In Vitro Medical Diagnostic Devices (98/79/EC) Annex III self-declared ISO 8655 STANDARD CERTIFIED ISO9001 Thank you

More information

PICO Cleaning Instructions

PICO Cleaning Instructions PICO Cleaning Instructions How to clean PICO piezoelectric metering valves IMPORTANT! Save this Sheet. Forward to Maintenance or Tool Crib Supervisors Electronic pdf files of EFD manuals are also available

More information

Instruction Manual Bedienungsanleitung Mode d emploi Manual de Instrucciones Instruzioni d impiego BIOH T

Instruction Manual Bedienungsanleitung Mode d emploi Manual de Instrucciones Instruzioni d impiego BIOH T TM eline Instruction Manual Bedienungsanleitung Mode d emploi Manual de Instrucciones Instruzioni d impiego BIOH T BIOH T TM eline Instruction Manual...1 Bedienungsanleitung...37 Mode d emploi...73 Manual

More information

Operating Manual for. Dispenser. Read this manual thoroughly before operating the Labmax Bottle Top Dispenser!

Operating Manual for. Dispenser. Read this manual thoroughly before operating the Labmax Bottle Top Dispenser! Operating Manual for Dispenser Read this manual thoroughly before operating the Labmax Bottle Top Dispenser! General Safety Precautions When using the Labmax please observe the following safety precautions

More information

9. WARRANTY INFORMATION

9. WARRANTY INFORMATION 1. YOUR NEW PIPETTE FILLER... 2 2. UNPACKING AND PREPARING THE PIPETTE FILLER FOR USE 2 2.1 Charging the Pipette Filler... 2 2.2. Electrical specifications 3 3. Pipette Filler OVERVIEW... 3 4. Pipette

More information

KeContact P20. User manual

KeContact P20. User manual KeContact P20 User manual Comments to this manual In this manual you will find warnings against possible dangerous situations. The used symbols apply to the following meanings:!! WARNING! Indicates a potentially

More information

Pressure relief valve

Pressure relief valve Pressure relief valve Operating manual Series DHV 712 Version BA-2015.10.20 EN Print-No. 300 510 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0

More information

HV angle valve with single acting pneumatic actuator and closing spring (NC)

HV angle valve with single acting pneumatic actuator and closing spring (NC) Installation, Operating & Maintenance Instructions HV angle valve with single acting pneumatic actuator and closing spring (NC) Series 264 DN 100 160 mm (I. D. 4 6 ) This manual is valid for the following

More information

Exchange of rollers from the XTS-Mover

Exchange of rollers from the XTS-Mover Service documentation for AT901-0050-0550 and AT9011-00x0-0550 Version: Date: 1.0 0.10.017 Table of contents Table of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1. Documentation issue

More information

Eppendorf Research pro. Instruction Manual Mode d emploi Manual de Instrucciones

Eppendorf Research pro. Instruction Manual Mode d emploi Manual de Instrucciones Eppendorf Research pro Instruction Manual Mode d emploi Manual de Instrucciones Inhalt / Contents / Sommaire / Indice / Indice Teil A / Part A / Section A / Parte A / Parte A Contents / Sommaire / Indice

More information

Operator s Guide for Fixed Volume Pipettes (Ovation F1 and Ovation F2)

Operator s Guide for Fixed Volume Pipettes (Ovation F1 and Ovation F2) Operator s Guide for Fixed Volume Pipettes (Ovation F1 and Ovation F2) L057-0189-001 Rev. C TABLE OF CONTENTS Introduction Product Description & Specifications 1-1 Pipette Components 1-2 BioNatural Pipetting

More information

Digital Burette. Assembly and operating instructions. For capacities of 30ml & 50ml

Digital Burette. Assembly and operating instructions. For capacities of 30ml & 50ml Digital Burette Assembly and operating instructions For capacities of 30ml & 50ml General Safety Instructions Careful safety precautions must apply when dispensing corrosive, radioactive or hazardous chemicals.

More information

Installation, Operating & Maintenance Instructions. HV angle valve with pneumatic actuator single acting with closing spring (NC)

Installation, Operating & Maintenance Instructions. HV angle valve with pneumatic actuator single acting with closing spring (NC) Installation, Operating & Maintenance Instructions HV angle valve with pneumatic actuator single acting with closing spring (NC) Series 264 DN 10 50 mm (I. D. ⅜" 2") HV inline valve with pneumatic actuator

More information

XCM12 Mini-Centrifuge

XCM12 Mini-Centrifuge Multi-speed Digital User Manual v. 1.0 C&A Scientific Disclaimer C & A Scientific owns the copyright of this user manual. No person shall reprint or distribute the contents of this user manual, including

More information

Tempo PIPETTE CONTROLLER USER GUIDE. Masters of precision

Tempo PIPETTE CONTROLLER USER GUIDE. Masters of precision Tempo PIPETTE CONTROLLER USER GUIDE Masters of precision www.capp.dk Tempo You have made a very wise decision in investing in the CAPPTempo TM advanced motorised pipette controller. Not only does CAPPTempo

More information

anual N) - English MixMate 5353 from serial number 10,000 Service manual - English

anual N) - English MixMate 5353 from serial number 10,000 Service manual - English al - English ixmate anual N) - English 5353 from serial number 10,000 MixMate 5353 from serial number 10,000 Service manual - English Copyright 2014 Eppendorf AG, Hamburg. All rights reserved, including

More information

Medimachine II. Dissociator and Homogenizator USER MANUAL. (code )

Medimachine II. Dissociator and Homogenizator USER MANUAL. (code ) Medimachine II Dissociator and Homogenizator (code 121600) USER MANUAL Copyright C.T.S.V. srl. All rights reserved. No part of this user manual may be reproduced, stored in a retrieval system, transmitted,

More information

Dispensette. Testing Instructions (SOP) 1. Introduction. May 2009

Dispensette. Testing Instructions (SOP) 1. Introduction. May 2009 Dispensette Testing Instructions (SOP) May 2009 1. Introduction The standard ISO DIS 8655 describes both the design and the testing of the bottle-top dispenser. The following Testing Instructions describe

More information

DURAN GROUP DISPENSER & DURAN GROUP DISPENSER PRO. A safe and precise dispensing system

DURAN GROUP DISPENSER & DURAN GROUP DISPENSER PRO. A safe and precise dispensing system DURAN GROUP DISPENSER & DURAN GROUP DISPENSER PRO A safe and precise dispensing system REMOVAL OF LIQUID MEDIA MADE EASY DURAN laboratory glassware ensures outstanding safety and precision when working

More information

Instruction Manual for the Revolutionary Science RS-200 RevSpin Microcentrifuge

Instruction Manual for the Revolutionary Science RS-200 RevSpin Microcentrifuge Instruction Manual for the Revolutionary Science RS-200 RevSpin Microcentrifuge REVOLUTIO NARY SCIENCE Manufacturer of Precision Laboratory Equipment Table of Contents Introduction 2 Recommended Safeguards

More information

TopPette Mechanical Pipettes

TopPette Mechanical Pipettes TopPette Mechanical Pipettes Features for TopPette - Lightweight, ergonomic, low force design - Digital display clearly reads volume setting - The pipettes cover volume range of 0.1μl to 10ml - Easy to

More information

SERVICE MANUAL ACROSS Pro Pipette

SERVICE MANUAL ACROSS Pro Pipette SRVIC MNUL SRVIC MNUL CROSS Pro Pipette Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ 07054 (973) 377-9000 SRVIC MNUL CROSS Pro Pipette The information contained in this manual is believed

More information

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions Drive Unit e-drive1 Installation instructions 04/2014 English translation of the original German installation instructions Contents Foreword... 3 Availability... 3 Structural features in the text... 3

More information

VistaLab Technologies, Inc. 27 Radio Circle Drive Mt. Kisco, NY USA

VistaLab Technologies, Inc. 27 Radio Circle Drive Mt. Kisco, NY USA ! Use of the Ovation pipette not specified in this manual may impair protection provided by the equipment. For the most current information about Ovation pipettes, tips and accessories, see www.vistalab.com.

More information

HDE 500-A22. English. Printed: Doc-Nr: PUB / / 000 / 03

HDE 500-A22. English. Printed: Doc-Nr: PUB / / 000 / 03 HDE 500-A22 English 1 Information about the documentation 1.1 About this documentation Read this documentation before initial operation or use. This is a prerequisite for safe, trouble-free handling and

More information

Chapter 5. Caring for your pipette. Step 1 Check the records

Chapter 5. Caring for your pipette. Step 1 Check the records Caring for your pipette 38 Chapter 5 For long life and optimum performance, pipettes should be returned for complete service once a year. If you do encounter a minor technical difficulty, chances are very

More information

UV-cabinet DNA/RNA UVC/T-M-AR

UV-cabinet DNA/RNA UVC/T-M-AR UV-cabinet DNA/RNA For version V.4GD Contents 1 Safety...4 2 General Information...5 3 Getting Started...6 4 Operation of...7 5 Specifications...9 6 Guarantee and service...10 7 Declaration of Conformity...11

More information

The Efficient Solution for Pipetting up to 100 ml at once! USER'S GUIDE

The Efficient Solution for Pipetting up to 100 ml at once! USER'S GUIDE The Efficient Solution for Pipetting up to 100 ml at once! This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the User s Guide, may

More information

Perfection in Liquid Handling PRECISE AND CONVENIENT PIPETTING

Perfection in Liquid Handling PRECISE AND CONVENIENT PIPETTING Perfection in Liquid Handling PRECISE AND CONVENIENT PIPETTING 21 VITLAB micropipette The VITLAB piston-operated pipettes are the ideal manual pipettes for demanding laboratory applications, and have all

More information

250L Cartridge Dual Seal

250L Cartridge Dual Seal INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 250L Cartridge Dual Seal Installation, Operation and Maintenance Instructions TABLE OF CONTENTS 1.0 Cautions...2 2.0 Transport and Storage...2 3.0 Description...2

More information

Finnpipette Novus. Single Channel & Multichannel. User Manual. Instructions for Use

Finnpipette Novus. Single Channel & Multichannel. User Manual. Instructions for Use User Manual Finnpipette Novus Single Channel & Multichannel Instructions for Use Thermo Fisher Scientific Thermo Scientific Novus SCP/MCP User Manual 1 CONTENT PRODUCT DESCRIPTION...............................

More information

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009 Transferpette Testing Instructions (SOP) May 2009 1. Introduction The standards DIN EN ISO 8655 describe both the design and the testing of the piston operated pipette Transferpette. The following Testing

More information

Operating and Installation Instructions Diaphragm Gas Sampling Pumps

Operating and Installation Instructions Diaphragm Gas Sampling Pumps Operating and Installation Instructions Diaphragm Gas Sampling Pumps UN026FT.16I UN726FTI UN726FT.29I KNF Neuberger, Inc 2 Black Forest Rd Trenton, NJ 08691-1810 Phone: 609-890-8600 Fax: 609-890-8323 www.knf.com/usa.htm

More information

01 / Pralinenfix PFM 2000

01 / Pralinenfix PFM 2000 01 / 2011 New Now available Especially for the filling of liquor we can now offer an new special nozzle ör For more information talk to your Costumer consultant Artikel Nr.: 29. 10. 08 Annex 1 PFM 2000

More information

Heavy Duty Bottle Jacks

Heavy Duty Bottle Jacks Heavy Duty Bottle Jacks Models: 10300 & 10500 10300 10500! This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol

More information

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM 150 150 150 This instruction manual contains proprietary information which is protected by copyright laws. No part of

More information

OPERATIONS MANUAL LEVER CHAIN HOIST

OPERATIONS MANUAL LEVER CHAIN HOIST OPERATIONS MANUAL LEVER CHAIN HOIST IMPORTANT SAFETY INFORMATION Please read, understand and follow all safety information contained in these instructions prior to the use of this hoist. Retain these instructions

More information

Angle seat valve with piston actuator VZXA-...-K

Angle seat valve with piston actuator VZXA-...-K Angle seat valve with piston actuator VZXA-...-K Festo AG & Co. KG Postfach 73726 Esslingen Germany +49 711 347-0 www.festo.com 3 Further information Accessories www.festo.com/catalogue Spare parts www.festo.com/spareparts

More information

Efficiency in variable pipetting

Efficiency in variable pipetting Efficiency in variable pipetting Microliter pipettes with variable volumes VITLAB micropipette VITLAB specialises in accurate dispensing, titration and pipetting, and offers a variety of highly developed

More information

Medimachine II. Dissociator and Homogenizator USER MANUAL. (code )

Medimachine II. Dissociator and Homogenizator USER MANUAL. (code ) Medimachine II Dissociator and Homogenizator (code 121600) USER MANUAL Copyright C.T.S.V. srl. All rights reserved. No part of this user manual may be reproduced, stored in a retrieval system, transmitted,

More information

Installation, Operating & Maintenance Instructions. UHV gate valve with pneumatic actuator. Series 108 DN mm (I. D. 2½ 8 )

Installation, Operating & Maintenance Instructions. UHV gate valve with pneumatic actuator. Series 108 DN mm (I. D. 2½ 8 ) Installation, Operating & Maintenance Instructions UHV gate valve with pneumatic actuator Series 108 DN 63 200 mm (I. D. 2½ 8 ) This manual is valid for the following product ordering numbers: 108.. -.

More information

4 - SETTING UP THE MACROMAN CHARGING POSITION 4 Wall mounted 4 Workbench set-up 4

4 - SETTING UP THE MACROMAN CHARGING POSITION 4 Wall mounted 4 Workbench set-up 4 User's Guide Contents Page 1 - SAFETY SYMBOLS USED 3 2 - PROPER USE 3 3 - SAFETY PRECAUTIONS 3 Possible dangers if the safety precautions are not observed 3 Safety at work 3 Safety aspects for the user

More information

RAUTOOL G2 BATTERY HYDRAULIC TOOL KIT PRODUCT INSTRUCTIONS. Construction Automotive Industry

RAUTOOL G2 BATTERY HYDRAULIC TOOL KIT PRODUCT INSTRUCTIONS.   Construction Automotive Industry RAUTOOL G2 BATTERY HYDRAULIC TOOL KIT PRODUCT INSTRUCTIONS www.rehau.com Construction Automotive Industry TABLE OF CONTENTS Safety Information... 3 Items Supplied............................................4

More information

Industrial flue gas probes. Instruction manual

Industrial flue gas probes. Instruction manual Industrial flue gas probes Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 Safety and the environment... 4 2.1. About this document... 4 2.2. Ensure safety... 4 2.3. Protecting the environment...

More information

Hydraulic Long Jacks

Hydraulic Long Jacks Operating Instructions & Parts Manual Hydraulic Long Jacks Model 44915 44930 44940 44980 44981C (Air option) Capacity 1-1/2 Ton 3 Ton 4 Ton 8 Ton 8 Ton Models 44915, 44930, 44940 & 44980 Model 44981C U.S.

More information

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D.

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D. Installation, Operating & Maintenance Instructions HV gate valve with pneumatic actuator Series 110 DN 250 320 mm (I. D. 10" 12") This manual is valid for the following product ordering numbers: 11048-.

More information

Instructions for Fitting, Operating and Maintenance Canopy Door RE / (St.: )

Instructions for Fitting, Operating and Maintenance Canopy Door RE / (St.: ) EN Instructions for Fitting, Operating and Maintenance Canopy Door 1 818 012 RE / (St.: 12.2010) 12.2010 ENGLISH Contents 1 Safety Instructions... 3 1.1 Qualified persons... 3 1.2 Symbols and signal words

More information

EP1306N 5 Gallon Can Extruder System Rev. A June EP1306N Operation Manual

EP1306N 5 Gallon Can Extruder System Rev. A June EP1306N Operation Manual EP1306N Operation Manual 1 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK 2 TABLE OF CONTENTS SECTION 1: SAFETY... 4 1. GENERAL SAFETY... 5 2. PUMP SAFETY... 5 3. FLUID PRESSURE AND COMPATIBILITY... 6 4.

More information

basic quattro No /

basic quattro No / basic quattro No. 2954-0000 / 2954-1000 Bedienungsanleitung Instruction manual Mode d emploi Istruzioni d uso Instrucciones para el servicio Gebruiksaanwijzing Instrukcja obsługi Инструкция по эксплуатации

More information

Assembly and Maintenance Manual Type ASNU

Assembly and Maintenance Manual Type ASNU Assembly and Maintenance Manual Type ASNU Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_ASNU.docx

More information

Rectangular Door L-VAT with pneumatic actuator double acting

Rectangular Door L-VAT with pneumatic actuator double acting Rectangular Door L-VAT with pneumatic actuator double acting This manual is valid for the products: 0 7 5 1 0 U A 2 4 0 0 0 1 4 character option code Size 10... 46 x 236 12... 50 x 336 Actuator 24... without

More information

MagicLift Hydraulic Service Jack Model (w/one piece handle) (w/one piece handle)

MagicLift Hydraulic Service Jack Model (w/one piece handle) (w/one piece handle) Operating Instructions & Parts Manual MagicLift Hydraulic Service Jack Model 27025 27026 (w/one piece handle) 27035 27036 (w/one piece handle) Capacity 2-1/2 Ton 2-1/2 Ton 3-1/2 Ton 3-1/2 Ton Model 27025

More information

HEAVY DUTY TROLLEY JACK. Operation Manual

HEAVY DUTY TROLLEY JACK. Operation Manual HEAVY DUTY TROLLEY JACK 4T Operation Manual Make sure to read and fully understand the instruction manual before using this product and keep the manual properly 1 General Description Product Description

More information

Installation, Operation, and Maintenance Manual. Welker Automatic Insertion Corrosion Coupon Device Model AID-1CC

Installation, Operation, and Maintenance Manual. Welker Automatic Insertion Corrosion Coupon Device Model AID-1CC Installation, Operation, and Maintenance Manual Welker Automatic Insertion Corrosion Coupon Device Model The information in this manual has been carefully checked for accuracy and is intended to be used

More information

English. Instruction and operation manual S 212. Dew point sensor

English. Instruction and operation manual S 212. Dew point sensor English Instruction and operation manual S 212 Dew point sensor Dear Customer, thank you for choosing our product. The operating instructions must be read in full and carefully observed before starting

More information

Operating Instructions & Parts Manual

Operating Instructions & Parts Manual Swift Lift Hydraulic Service Jack Operating Instructions & Parts Manual Model Number ATD7341 Capacity 3-1/2 Ton U.S. Patent No's. 5,946,912 6,199,379! This is the safety alert symbol. It is used to alert

More information

testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual

testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung de Instruction Manual en 18 General Information General Information Please read this document through carefully and familiarise yourself

More information