STH/Q SET UP INSTRUCTIONS

Size: px
Start display at page:

Download "STH/Q SET UP INSTRUCTIONS"

Transcription

1 !! STH/Q SET UP INSTRUCTIONS FOR ADDITIONAL REFERENCES SEE H431 AND Q431 Before using any Fluid Metering, Inc. product read the following safety instructions as well as specific product specifications and operating instructions. Warning! Fire, electrical shock or explosion may occur if used near combustibles explosive atmosphere, corrosive air, wet environment or submerged in fluid. Disconnect electrical power before checking pump for any problems. Connect motor, speed controllers, or any other electrical devices based on Fluid Metering Inc. specifications. Any unauthorized work performed on the product by the purchaser or by third parties can impair product functionality and thereby relieves Fluid Metering, Inc. of all warranty claims or liability for any misuse that will cause damage to product and/or injury to the individual. Power cables and leads should not be bent, pulled or inserted by excessive force. Otherwise there is a threat of electrical shock or fire. Replace any inline fuses only with fuse rating as specified by Fluid Metering, Inc. When pump/drive is under operation, never point discharge tubing into face or touch any rotating components of pump. In a power down thermal overload cut-in condition, unplug or turn off power to pump. Always allow a cool down period before restarting: otherwise, injury or damage may occur. For 30 seconds after power is removed from pump/drive: do not touch any output terminals. Electrical shock may occur because of residual voltage. SAFETY INSTRUCTIONS! Caution! Fire, electrical shock, injury and damage may occur if not used in accordance with Fluid Metering, Inc. specifications and operation instructions. Do not put wet fingers into power outlet of unit. Do not operate with wet hands. Do not operate drive assemblies that require a hard mount (to be bolted down) unless they are mounted per Fluid Metering, Inc. specifications, if not injury may occur and/or damage to unit. Do not touch any rotating pump or motor components: injury may occur. Do not run pump dry, unless designed for that service. Running dry is harmful to the pump, and will cause excessive heating due to internal friction. Check pump rotation and inlet/outlet pump port orientation before connecting power to pump. If not injury may occur. When pulling out cords from outlets do not pull cord, grasp plug to prevent plug damage or electrical shock. Fluid Metering, Inc. Drive Motors become HOT and can cause a burn. DO NOT TOUCH! REQUIRED TOOLS: 1. Analytical Pan Balance 2. Hex Key Driver for Adjusting Stroke Length: STH: 3/32" Hex Driver STQ: 7/32" Hex Driver 3. A removable wicking thread lock (loctite 290) 1.0 PUMP MOUNTING: For optimum pump performance it is recommended that your FMI pump be mounted in a vertical position with the pump head down in a 6:00 o'clock position and the motor at 12:00 o'clock. This orientation will allow air bubbles that enter the pumping chamber to directly exit through buoyancy assistance. Figure A 2.0 GENERAL SET-UP 2.1 Setting Dispense Stroke Rate Strokes Per Minute (spm): For fluids of 500cps viscosity or less a stroke rate of spm max is ideal. For fluids with greater than 500cps a slower rate is recommended. 2.2 Fluidics: Inlet (Suction) Tubing: To avoid cavitation use the most resilient tubing possible with the largest inside diameter (I.D.) Outlet (Dispense) Tubing: For best dispense performance use rigid Teflon tubing (to reduce peristaltic action) with an equal or smaller I.D. than the inlet (suction) tubing. Figure A 1

2 2.3 Step Motors: FMI ST pumps are supplied with a 17 or a 23 frame Motors. For wiring diagram and detailed motor specifications go to the literature section of our website at Rotational Sensor: FMI STH and STQ standard pumps are supplied with an LED rotational sensor. For wiring diagram and sensor details see Figure F For sensor use with FMI SCST-01 Step Motor Controller. See SCST-01 instructions. 2.5 STH Pump Homing: Best dispensing performance of the pump is obtained by proper set up of the start/stop position of the piston relative to the intake port of the pump housing. Positioning of the piston flat so that it directly faces the inlet port is termed homing. The images below show the home position for a pump which has been set up to turn clockwise. In this case the inlet port is on the left. If a particular application calls for the inlet port to be on the right, the pump will be programmed to turn counterclockwise and the figures bellow must be reversed. 2.6 Park Position: Preventive maintenance steps in order to minimize the possibility of a frozen pump or seize condition are as follows: a) Always completely flush out the pump with water if it will be in an idle (non-operating mode) for an extended period of time. b) During shut down leave the pump s fluid circuit wet with flush water. c) The piston position should extend all the way towards the bottom of the liner. This is known as the PARK position. Correct programming of pump motion to achieve the PARK position involves the following sequence (assuming clockwise rotation for operation). Step #1 The FMI pump stops (any location). Step #2 While monitoring sensor signal, instruct motor to turn clockwise while looking for the leading edge of the flag (see figure 2 below). Flag Edge Approaching Sensor Home Position Piston flat approaching alignment with inlet port Piston flat facing inlet port Figure 2 Figure 1 Step #3 Next rotate Counter Clockwise 90 Degrees the pump is now PARKED. 2

3 The design of FMI Pumps is unique throughout the world. Having no valves and only one moving part, the piston makes this design very special. No valves means that our ceramic pistons and cylinders must be matched to extremely close fits so that stroke to stroke accuracy is maintained. This precision fit requires some general maintenance rules. When a pump is allowed to sit idle and dry out, these dried precipitate can form in the piston/cylinder clearance and cause a pump seizure condition. Upon system power up, this seizure can result in either no flow or at worst a broken piston. So we recommend the above procedure. a) Soak the top portion of the pump (PUMP HEAD ONLY) in a warm water bath for at least 20 minutes. Then place your index finger and thumb around the spindle assembly (gold coupling) and gently try to rotate the assembly back and forth in an attempt to loosen up the piston. CAUTION: Do not force the assembly free if it is severely frozen as this could result in piston breakage or pump damage. We do not live in a perfect world and accidents do happen. If your pump seizes try the following procedures: With the pump in an instrument: 1) Cycle the pump in a back and forth motion (clockwise and counter clockwise rotation) at a slow speed in a high torque mode. 2) Start and stop the pump in an effort to free system. 3) If pump head is accessible try turning the drive spindle back and forth with your index finger and thumb. 2.7 Maintenance With the Pump/Drive Assembly removed from the instrument but not disassembled (WILL NOT REQUIRE PUMP RECALIBRATION): 3

4 With the Pump/Drive Assembly removed from the instrument and the piston/cylinder group removed (MAY REQUIRE PUMP RECALIBRATION): b) If the pump is severely frozen then the piston/cylinder group must be removed from the pump. Remove the (2) screws that secure the H435 Cap to the pump base assembly and carefully remove (twist, tilt & pull) the piston/cylinder group from the pump base assembly. d) Reassemble the piston/cylinder into the pump base assembly (use FMI Instructions H431) page # 8 section # 22 for more details relative to installing the piston/cylinder assembly. H435 Cap Screws(2) Tighten to 9 in-lbs torque CAUTION as shown e) Reinstall H435 Cylinder Cap and apply a suitable thread lock to the screws (Loctite # 425) and secure screws (torque to 9 in-lbs). f) Rotate the assembly to assure it moves smooth and free. (If not see note #1 below). c) Soak the piston/cylinder group in warm water for 20 minutes minimum. For quickest results use an ultrasonic bath. Then try to loosen up the assembly by hand - gently rotating the piston back and forth until free. CAUTION: Do not pull piston out of cylinder or force the piston as breakage or seal damage will occur. g) Check the pump for proper calibration (If out of specification see note #1 below). Note#1: Please return complete pump/drive unit to the factory for rework and recalibration 4

5 3.0 CALIBRATION AND TESTING 3.1 Flush the system: clean with alcohol or other suitable cleaning/wetting agent before using the hydraulics and pump for the first time. Prime pump with fluids to assure system is free of air bubbles. 3.2 Place pump in the standard "home" position with the piston-flat perpendicular to the inlet port.the inlet port will be on the left when the motor rotates clockwise (see Figure B for the STH pump and Figure C for the STQ pump). 3.3 Check the pump's dispense volume by cycling the pump for one complete 360 revolution (one complete rotation). Dispense onto an analytical pan balance and observe the volume. See Figure D. Readjust as necessary. pan Balance REMARK: When dispensing water-like solutions assume 1 ml = 1 gram. A correction factor will be required for other fluids Figure D Note: Calibration is Factory set and Should not be Changed. Figure B Figure C 5

6 3.4 Dispense Volume Values for FMI STH/STQ Pumps: MODEL NOTE: To assure the best performance set the pump displacement volume as large as possible. FMI pumps are calibrated at the factory to the maximum value. Both STH and STQ pumps can be factory adjusted down to as little as 10% of the rated flow. 3.5 Adjusting Dispense Volumes: To fine adjust dispense volumes rotate the stroke length adjustment s crew using the appropriate hex driver (see Required Tools on page 1). To increase the flow, turn the screw counter-clockwise. To decrease the flow, turn the screw clockwise CCW=Increase, CW=Decrease. CAUTION: DO NOT LOOSEN THE HEX LOCK NUT WHEN ADJUSTING THE STROKE RATE. IT IS SET AT THE FACTORY AND SHOULD NOT BE TAMPERED WITH. See Figure E 3.6 Lock setting: ML/REV MIN ML/REV MAX STH STH STH STQ STQ STQ STQ ) Splashing can usually be avoided by modifying dispense tip to larger I.D.and/or decreasing dispense speed. 4) Hanging drop at dispense tip can be avoided by: a) Use of rigid discharge tubing b) Small dispense tip c) Increasing speed 5) High viscosity dispensing requires: a) Large suction tubing b) Pressurizing suction reservoir 6) Bubbles in discharge a) Suction fitting leak b) Cavitation 7) Need Help? Call, fax, or us We can help solve almost any fluid control problem. 3.8 SPECIAL MOTORS AND CONTROLLERS FMI offers a complete variety of stepper motors and stepper motor controllers from simple quick start control to complex application specific stepper motor control. Our standard step motor controllers are: SCST General Purpose Stepper Motor Control for quick start control of FMI STH and STQ pumps. ICST Intelligent Stepper Motor Controller which includes an embedded microprocessor for custom programming of FMI stepper motor pumps to meet specific application operations. IDS 2000 Industrial Dispenser/Pump which includes the SCST and FMI pump head integrally mounted in a rugged stainless steel enclosure. Once the pump is calibrated apply a drop of removable wicking thread lock between the lower pivot pin and the adjustment screw threads. See Figure E. 3.7 Dispensing Hints: 1) Speed - Optimum results for fluids 500 cps or less is between rpm. 2) Cavitation: Use the largest suction tubing you can to avoid cavitation. 6

7 NOTE:FOR ADDITIONAL REFERENCES SEE H431 AND Q431 Figure E Absolute Maximum Rating (TA=25ºC Unless otherwise noted) Supply voltage, V (not to exceed 3 sec.)...18 V Input diode power dissipation mw (1) Output power dissipation mw (2) Total device power dissipation mw (3) Voltage at output lead (open collector output)...35 V Diode foreword D.C Current...40 ma Diode reverse D.C Voltage...2 V Note: 1. Derate linearly 2.22mW / ºC above 25ºC 2. Derate linearly 4.44mW / ºC above 25ºC Rotational Sensor Vcc Vcc 3. Derate linearly 6.66mW / ºC above 25ºC 4. The optical switches are terminated with 24 inches of 26 A.W.G.,UL 1492 wire on each terminal. Insulation colors and function are as follows: Red-Anode, Black-Cathode, White-Vcc, Blue-Output, Green-Ground 5. Normal application would be used with light source blocked, simulated by IF=0mA 6. All parameters tested using pulse techniques. * NOT SUPPLIED WITH OPTICAL SENSORS See suggested Rd values table below. Suggested RD Values Vcc (VDC) RD (Ω) Minimum supply voltage is 4.5 VDC Figure F 7

by Instrumentation Pumps 1 / 8

by Instrumentation Pumps 1 / 8 600-000 by Instrumentation Pumps 1 / 8 1. Safety Requirements... 3 2. Pump Mounting... 3 3. General Set Up... 4 3.1. Quick Start... 4 3.2. Speed... 5 3.3. Fluidics... 5 4. Maintenance... 5 4.1. Idle Position...

More information

IDS INDUSTRIAL DISPENSER INSTRUCTIONS ISO SAFETY INSTRUCTIONS

IDS INDUSTRIAL DISPENSER INSTRUCTIONS ISO SAFETY INSTRUCTIONS ISO9 SAFETY Before using any Fluid Metering, Inc. product read the following safety instructions as well as specific product specifications and operating instructions. Warning! Fire, electrical shock or

More information

Table Of Contents. Section Description Page #

Table Of Contents. Section Description Page # SPLIT CASE PUMP MODULE Page 7-1 Table Of Contents Section Description Page # 7. Split Case Pump Module... 7-2 7.1 Description... 7-2 7.2 Operation... 7-2 7.2.1 Piston/Cylinder Set... 7-3 7.2.2 Split Case...

More information

SERVICE INSTRUCTIONS. Transfer Pump

SERVICE INSTRUCTIONS. Transfer Pump TM TM SERVICE INSTRUCTIONS Transfer Pump 6799 DESCRIPTION Model 6799 is an air operated, self-priming, piston type transfer pump designed to transfer gasoline or diesel fuel at 30 gpm or oils up to SAE

More information

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J 1 IMPORTANT: READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING. PUMP DATA TYPE: MAT'L: WEIGHT: Air Operated Double Diaphragm Polypropylene or PVDF or Acetal PVDF (Polyvinylidene Fluoride)

More information

MICRO SL PUMP MODULE Page 7-1. Table Of Contents. Section Description Page #

MICRO SL PUMP MODULE Page 7-1. Table Of Contents. Section Description Page # MICRO SL PUMP MODULE Page 7- Table Of Contents Section Description Page # 7. Micro SL Pump Module... 7-2 7. Description... 7-2 7.2 Operation... 7-2 7.2. Piston/Cylinder Set... 7-2 7.3 Installation... 7-3

More information

UV PROCESS SUPPLY, INC.

UV PROCESS SUPPLY, INC. UV PROCESS SUPPLY, INC. GENERAL DESCRIPTION The ¼ Diaphragm Pump others high volume delivery even at low air pressures, easy self-priming, the ability to pump various viscosity materials and the ability

More information

VMP Pump Modules. TSi-Vc. Zaxis, Inc S W. Salt Lake City, Utah 84119

VMP Pump Modules. TSi-Vc. Zaxis, Inc S W. Salt Lake City, Utah 84119 VMP Variable Metering Pump User Manual VMP Pump Modules VMP-OEM, VMP Micro, VMP500-2 TSi-Vc Touch Screen Interface, Teach Pendant. Zaxis, Inc. 2442 S. 2570 W. Salt Lake City, Utah 84119 Phone: (801) 264-1000,

More information

T21 Thermal Differential Switch

T21 Thermal Differential Switch T21 Thermal Differential Switch General Instructions The T21 Point Level Switch is a state-of-the-art in liquid level and interface measurement and control. Level detection is accomplished by using a high-resolution

More information

Techcon Systems TS5000 Series Rotary Valve

Techcon Systems TS5000 Series Rotary Valve 10. SPARE PARTS AND ACCESSORIES 10.1 SPARE PARTS: The only spare parts available are: Fluid inlet fitting, O- ring and clean out screw. These items are included in the Valve cleaning kit part number: 5000-013-000

More information

Purging Air From Divider Block Lubrication Systems

Purging Air From Divider Block Lubrication Systems FROST ENGINEERING SERVICE Purging Air From Lubrication Systems A D I V I S I O N O F G E C S E Y S A L E S & S E R V I C E DESCRIPTION Divider block lubrication systems operate correctly only when all

More information

LINEAR ACTUATOR MODULE Page 5-1. Table Of Contents

LINEAR ACTUATOR MODULE Page 5-1. Table Of Contents LINEAR ACTUATOR MODULE Page 5-1 Table Of Contents Section Description Page # 5. Linear Actuator Module... 5-2 5.1 Description... 5-2 5.2 Operation... 5-2 5.2.1 Sensors... 5-3 5.2.1.1 Linear Sensor... 5-3

More information

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS TO OBTAIN THE BEST PERFORMANCE FROM YOUR PROMAG SR PUMP, PLEASE READ THE MANUAL CAREFULLY. Failure to

More information

Document Library TS Data Sheet Universal Fuel System Cleaner. Data Sheet. Public

Document Library TS Data Sheet Universal Fuel System Cleaner. Data Sheet. Public Document Library TS Data Sheet 08955 Public Rev:1 Effective: 11/03/2000 Status: Active Universal Fuel System Cleaner Data Sheet 3M Part No.(s) 3M Part Descriptor(s) 08955 Professional Formula Universal

More information

Dosing Pump Operational Manual

Dosing Pump Operational Manual Chemical Dosing Specialists Dosing Pump Operational Manual Pump Range WMPSP0110 - WMPSP0408 - WMPSP0607 - WMPSP0805 - WMPSP1204 - WMPSP1502 - WMPSP2001 1- Product Introduction 2 1.1 Product Overview 2

More information

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX: TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: +353 66 7121911 FAX: +353 66 7124503 e-mail: sales@tillotson.ie SERIES SERVICE MANUAL INTRODUCTION The gasoline engine industry

More information

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev. OPERATION MANUAL NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company 1/14 rev. 3 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to

More information

IN USA FAX:

IN USA FAX: MADDEN Manufacturing, Inc. P.O. Box 387 1317 Princeton Blvd. Elkhart, IN 46515 USA Phone: 574-295-4292 FAX: 574-295-7562 E-mail: info@maddenmfg.com Website: www.maddenmfg.com Form no. JN MAN 11 SPECIFICATIONS

More information

OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 7/11 rev. 1

OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 7/11 rev. 1 OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company 7/11 rev. 1 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to 93.3 C 0 F to 200 F Buna-N -12.2

More information

4000 SYSTEM OPERATING MANUAL

4000 SYSTEM OPERATING MANUAL 4000 SYSTEM OPERATING MANUAL REV 1.4 COPYRIGHT 1996 Xenotech, Inc. PAGE 1 INSTRUCTIONS FOR REMOVING AND INSTALLING A TYPE XT XENON BULB IN A BL4000 FIXTURE NOTE FAMILIARIZE YOURSELF WITH THE LOCATION AND

More information

IDMHDV-120. Lever Operated Diaphragm Valve. User Manual

IDMHDV-120. Lever Operated Diaphragm Valve. User Manual IDMHDV-120 Lever Operated Diaphragm Valve User Manual www.intertronics.co.uk/idmhdv-120 17 Station Field Industrial Estate Banbury Road, Kidlington Oxfordshire, England OX5 1JD t 01865 842842 e sales@intertronics.co.uk

More information

Fluid-O-Tech ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL

Fluid-O-Tech ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL Fluid-O-Tech PUMP TECHNOLOGY AT ITS BEST WWW.FLUID-O-TECH.COM Office: 161 Atwater St., Plantsville, CT 06479 Phone: (860) 276-9270 Fax: (860) 620-0193 ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL 08/09 Ed.,

More information

Start-up: Dispensing by Volume

Start-up: Dispensing by Volume The Smart Pump Company Start-up: Dispensing by Volume Equipment: You will need the following items to get started: SciLog P/N Description Quantity 400-480 or 490 10 or 20 liter ADS Carboy 1 pc Or Appropriate

More information

Relius UV-Cure Adhesive Coating Dispenser Manual

Relius UV-Cure Adhesive Coating Dispenser Manual Relius UV-Cure Adhesive Coating Dispenser Manual User s Guide Electronic pdf files of EFD manuals are also available at www.efd-inc.com/manuals.html A NORDSON COMPANY Introduction You have selected a reliable,

More information

Maestro Piston Pump MP SERIES FS SERIES

Maestro Piston Pump MP SERIES FS SERIES Maestro Piston Pump MP SERIES FS SERIES User Manual 1 Table of Contents Table of Contents...1 1 Features...2 2 Outline dimensions and components not to scale...3 2.1 Without Flush Port Option [mm] in.

More information

OWNER S TECHNICAL MANUAL

OWNER S TECHNICAL MANUAL OWNER S TECHNICAL MANUAL 2.5kg Grease Kit 6336 Description The Champion 6336 2.5kg grease kit is a manually operated, spring powered grease kit that comes complete with a hand piece. It is designed to

More information

OWNER S TECHNICAL MANUAL. 6336N 2.5kg Grease Kit

OWNER S TECHNICAL MANUAL. 6336N 2.5kg Grease Kit OWNER S TECHNICAL MANUAL 6336N 2.5kg Grease Kit 6336N Description The 6336N 2.5kg grease kit is a manually operated, spring powered grease kit with ergonomic, user friendly rod cap that comes complete

More information

LAB PUMP JR. SAFETY INSTRUCTIONS INSTRUCTIONS FOR ALL H MODEL PUMPS MODELS RH, RHB, RHSY, RHV, PIP

LAB PUMP JR. SAFETY INSTRUCTIONS INSTRUCTIONS FOR ALL H MODEL PUMPS MODELS RH, RHB, RHSY, RHV, PIP INSTRUCTIONS FOR ALL H MODEL PUMPS MODELS RH, RHB, RHSY, RHV, PIP LAB PUMP JR. CONGRATULATIONS! THE FMI MICRO p-petter PiP IS ONE OF THE FINEST VOLUMETRIC DISPENSING SYSTEMS AVAIL- ABLE. IT FEATURES AN

More information

OPERATION MANUAL NT80 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2

OPERATION MANUAL NT80 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2 OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company 5/13 rev.2 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to 93.3 C 0 F to 200 F Buna-N -12.2 C to 82.2 C 10 F to 180

More information

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery Table 6-1. and solutions with pump operations No Fluid Delivery Fluid level in the reservoir is low. Oil intake pipe or inlet filter is plugged. Air leak in the inlet line prevents priming or causes noise

More information

TECHNICAL SERVICE MANUAL GENERAL PURPOSE BRACKET MOUNTED PUMPS SERIES 115 MODELS G, GX2, H and HX4

TECHNICAL SERVICE MANUAL GENERAL PURPOSE BRACKET MOUNTED PUMPS SERIES 115 MODELS G, GX2, H and HX4 TECHNICAL SERVICE MANUAL GENERAL PURPOSE BRACKET MOUNTED PUMPS SERIES 115 MODELS G, GX2, H and HX4 SECTION 2 BULLETIN TSM-115-C ISSUE A CONTENTS Special Information 2 Maintenance 2 Packed Pump Breakdown

More information

Techcon Systems TS7000 Series Interchangeable Material Path Rotary Valve

Techcon Systems TS7000 Series Interchangeable Material Path Rotary Valve Techcon Systems TS7000 Series Interchangeable Material Path Rotary Valve User Guide Copyright OK International CONTENTS Page number 1. Specifications 3 2. Unpacking and inspection 4 3. Description 4 4.

More information

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5 MODELS 282050, 282716 & 283513 AIR OPERATED CHASSIS PUMP SERIES A OWNER/OPERATOR MANUAL SPECIFICATIONS Airmotor effective dia. in. 2.5 Airinlet Material outlet 1/4 NPTF 1/4 NPTF Liquid to Air Pressure

More information

2 Model 826 Dispensing Valve User Guide

2 Model 826 Dispensing Valve User Guide 2 Model 826 Dispensing Valve User Guide About Dymax UV/Visible light-curable adhesives. Systems for light curing, fluid dispensing, and fluid packaging. Dymax manufactures industrial adhesives, light-curable

More information

Disc Brake System ( For Cross-Country)

Disc Brake System ( For Cross-Country) Technical Service Instructions General Safety Information Disc Brake System ( For Cross-Country) SI-8C60F t WARNING Please use extra caution to keep your fingers away from the rotating disc brake rotor

More information

Precision-24 Manual & Specification

Precision-24 Manual & Specification Precision-24 Manual & Specification 1 Product Introduction... - 1-1.1 Product Overview... - 1-1.2 Technical Parameter...- 2-1.2.1 General Parameter...- 2-1.2.2 Performance Parameter... - 3-1.2.3 Installation

More information

Maestro Piston Pump MP SERIES FS SERIES

Maestro Piston Pump MP SERIES FS SERIES Maestro Piston Pump MP SERIES FS SERIES User Manual 1 Table of Contents Table of Contents...1 1 Features...2 2 Outline dimensions and components not to scale...3 2.1 Without Flush Port Option [mm] in.

More information

SOLAROY 12 VDC Metering Pump

SOLAROY 12 VDC Metering Pump SOLAROY 12 VDC Metering Pump INSTALLATION, OPERATION, AND MAINTENANCE MANUAL MODEL NUMBER: SR-1PS-TC250 and SR-1PS-TC375 Manual #23858 Revision 2/2012 Precautions / Warnings: Proper fuse installation (to

More information

OPERATION MANUAL.25 METALLIC PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM

OPERATION MANUAL.25 METALLIC PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM OPERATION MANUAL.25 METALLIC PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM CAUTIONS - READ FIRST CAUTION: Do not apply compressed air to the exhaust port pump will not function. CAUTION: Do not exceed 79 C (174

More information

OPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

OPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS OPERATION MANUAL 2 METALLIC PUMP (CLAMPED) PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF50 AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models DUCTILE Models 316 S.S. Models A JDA Global Company CAUTIONS - READ

More information

Installation Guidelines

Installation Guidelines STYLE No. CODE No. GUPB81 GUSV81R IMPORTANT: To ensure this product is installed properly, you must read and follow these guidelines. STYLE No. CODE No. GUPB87 (with Diverter) GUSV87R The owner/user of

More information

EP1306N 5 Gallon Can Extruder System Rev. A June EP1306N Operation Manual

EP1306N 5 Gallon Can Extruder System Rev. A June EP1306N Operation Manual EP1306N Operation Manual 1 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK 2 TABLE OF CONTENTS SECTION 1: SAFETY... 4 1. GENERAL SAFETY... 5 2. PUMP SAFETY... 5 3. FLUID PRESSURE AND COMPATIBILITY... 6 4.

More information

Philapack, LLC. Filler Machine Division

Philapack, LLC. Filler Machine Division Philapack, LLC Filler Machine Division 1840 County Line Rd. #203, Huntingdon Valley, PA 19006 Telephone (215) 322-2122: Fax (215) 355-1509 Web site: www.philapack.com Parts Email: parts@philapack.com Machine

More information

Zaxis Valveless Metering Pump User Manual

Zaxis Valveless Metering Pump User Manual Zaxis Valveless Metering Pump User Manual Precision fluid metering with ultra-fine electronic adjustment Zaxis Inc. 79 W. 4500 S. Unit #21 Salt Lake City, UT. 84107 USA Phone: (801)-264-1000, Fax: (801)-265-8413

More information

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev. OPERATION MANUAL NTG50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company 1/14 rev.3 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to

More information

Instruction Manual CORDLESS DRILL & DRIVER 18V. Model SROM 1170

Instruction Manual CORDLESS DRILL & DRIVER 18V. Model SROM 1170 Instruction Manual CORDLESS DRILL & DRIVER 18V Model SROM 1170 Product Features: Dear Valued Customer, Thank you for purchasing this Samson Power Tool. We are dedicated to providing quality Samson Power

More information

PACKAGE LIST CONTENT. User Manual 1 GIMBAL STABILIZER 1 MICRO USB CABLE 1

PACKAGE LIST CONTENT. User Manual 1 GIMBAL STABILIZER 1 MICRO USB CABLE 1 CONTENT Package List...1 Disclaimer and Warning...2 Safety Operation Guidelines...4 USB Connection...7 Mounting Camera, Checking Balance...9 Panel Introduction...10 Operating Mode...11 Changing Orientation...12

More information

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG40 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14, Rev.

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG40 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14, Rev. OPERATION MANUAL NTG40 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company 1/14, Rev. 3 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to

More information

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves MicroCoat System Operating Manual MC Series MC785M, MC785M-WF Spray Valves A NORDSON COMPANY Introduction The MicroCoat System provides precise lubrication control for metal stamping operations. The MC

More information

Operating Manual Includes Pumps: PG-9000 Part #R809606

Operating Manual Includes Pumps: PG-9000 Part #R809606 Operating Manual Includes Pumps: PG-9000 Part #R809606 Introduction Thank you for selecting the PG Series Pumps from Lifegard Aquatics. Before using this pump please take a moment to review this manual.

More information

OWNER S MANUAL GUZZLER MODEL 620 READ THESE INSTRUCTIONS BEFORE USING

OWNER S MANUAL GUZZLER MODEL 620 READ THESE INSTRUCTIONS BEFORE USING OWNER S MANUAL GUZZLER MODEL 620 OPERATION MAINTENANCE TROUBLE SHOOTING REPAIR PARTS WARRANTY READ THESE INSTRUCTIONS BEFORE USING 201 COMMERCE DRIVE MONTGOMERYVILLE, PA 18936 215-393-4700 800-331-1423

More information

Operation and Maintenance Manual

Operation and Maintenance Manual BM / BMA Hydrometers ½ Operation and Maintenance Manual i This manual is intended for use by the users of this equipment. The information contained herein is the property of the Arad Ltd. Dalia and may

More information

INSTRUCTION MANUAL MODEL 213, 214, 215 and 216 POSITIVE DISPLACEMENT FLOWMETERS

INSTRUCTION MANUAL MODEL 213, 214, 215 and 216 POSITIVE DISPLACEMENT FLOWMETERS INSTRUCTION MANUAL MODEL 213, 214, 215 and 216 POSITIVE DISPLACEMENT FLOWMETERS TABLE OF CONTENTS Do s and Don ts.................................. Pg 2 General Description...............................

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

1/2" AIR DRIVEN DIAPHRAGM PUMP

1/2 AIR DRIVEN DIAPHRAGM PUMP 1/2" DRIVEN DIAPHRAGM PUMP OPERATION AND SERVICE GUIDE O-1225D NOV. 2008 Page 1 of 6 Refer to Bulletin P-605, Parts List P-9151 DRIVEN, DOUBLE DIAPHRAGM PUMP MANUAL Congratulations on purchasing one of

More information

Installation and Operating Manual

Installation and Operating Manual MOTORS AND DRIVES SIGNAL ISOLATOR Accessory for BC204 Regenerative Drive Installation and Operating Manual 4/2000 MN1387 TABLE OF CONTENTS Section Page i. Safety Warning..........................................................

More information

STAINLESS STEEL DETERGENT INJECTOR AW

STAINLESS STEEL DETERGENT INJECTOR AW STAINLESS STEEL DETERGENT INJECTOR AW-8000-0001 OPERATING INSTRUCTIONS & PARTS LIST CAUTION RISK OF INJURY! READ ENTIRE MANUAL BEFORE OPERATING! THIS MANUAL IS AN IMPORTANT PART OF THE INJECTOR AND MUST

More information

INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE

INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE 82013-800 January 2006 INDEX PAGE 1. General Information... 2 1.1 Description... 2 1.2 Safety precautions to be observed before operating the centrifuge...

More information

Fuel Tank Sweeper #9049 OPERATOR S MANUAL

Fuel Tank Sweeper #9049 OPERATOR S MANUAL Fuel Tank Sweeper #9049 OPERATOR S MANUAL Innovative Products of America Incorporated 888-786-7899 www.ipatools.com 234 Tinker Street, Woodstock, NY 12498 DO NOT USE WITH GASOLINE! Transfers, filters and

More information

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

Air Operated Diaphragm Pumps Operating and Maintenance Instructions Product & Chemical Disclaimer The user must take responsibility in the selection of the products materials of construction. Empire Pumps Ltd will act in an advisory role and offer recommendations; however,

More information

ORPscan20 Pocket ORP Tester Instruction Manual

ORPscan20 Pocket ORP Tester Instruction Manual ORPscan20 Pocket ORP Tester Instruction Manual BANTE INSTRUMENTS CO., LTD ORPscan20 Pocket ORP Tester 1 Thank you for selecting the ORPscan20 pocket ORP tester. This manual provides a step-by-step guide

More information

MODEL 905V OPERATING INSTRUCTIONS

MODEL 905V OPERATING INSTRUCTIONS MODEL 905V OPERATING INSTRUCTIONS Quantek Instruments 183 Magill Drive Grafton, MA 01519 Tel: (508) 839-3940 Fax: (508) 819-3444 Email: sales@quantekinstruments.com GENERAL DESCRIPTION These instructions

More information

OPERATION MANUAL. DUCTILE Models NT100 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2

OPERATION MANUAL. DUCTILE Models NT100 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2 OPERATION MANUAL NT100 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS DUCTILE Models A JDA Global Company 5/13 rev.2 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to 93.3 C 0 F to 200

More information

Operation & Maintenance Manual 4900 Series Pipeline Injection Pumps Bulletin 150

Operation & Maintenance Manual 4900 Series Pipeline Injection Pumps Bulletin 150 340 West Benson Avenue Grantsburg, WI 54840 1-800-366-1410 715-463-5177 www.northern-pump.com Table of Contents Introduction... 3 Rotation... 4 Hydraulic Balance... 5 Cautionary Statements... 6 Pump Installation...

More information

Troubleshooting 3Z8 038 Rev B

Troubleshooting 3Z8 038 Rev B Troubleshooting 3Z8 038 Rev B INSTRUCTIONS WARNING INJECTION HAZARD This form is only a quick reference for troubleshooting Graco sprayers. To reduce the risk of serious injury, including fluid injection,

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

PPM100 Owner s Manual

PPM100 Owner s Manual PPM100 Owner s Manual 187 E. 670 S., Kamas, UT 84036 435.783.6040 888.796.2476 https://wkfluidhandling.com Manuals available online at: wkfluidhandling.com/owners-manuals Manual Part #18200-LM-0001 Copyright

More information

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 2 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 50 BOLTED. A JDA Global Company

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 2 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 50 BOLTED. A JDA Global Company OPERATION MANUAL 2 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 50 BOLTED AIR-OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company CAUTIONS - READ FIRST CAUTION: Do not apply compressed air

More information

KENCO ENGINEERING COMPANY

KENCO ENGINEERING COMPANY KENCO ENGINEERING COMPANY P.O. BOX 470426 TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 www.kenco-eng.com e-mail: info@kenco-eng.com SERIES KTD THERMAL DIFFERENTIAL FLOW/LEVEL SWITCH INSTALLATION

More information

MOUNTING, OPERATING, TESTING & MAINTENANCE INSTRUCTIONS FOR ROTEX 3/2 DIRECT ACTING ON/OFF/REGULATING NAMUR SOLENOID VALVE MODEL 30318, 30318LW

MOUNTING, OPERATING, TESTING & MAINTENANCE INSTRUCTIONS FOR ROTEX 3/2 DIRECT ACTING ON/OFF/REGULATING NAMUR SOLENOID VALVE MODEL 30318, 30318LW Page 1 of 5 MOUNTING, OPERATING, TESTING & MAINTENANCE INSTRUCTIONS FOR ROTEX 3/2 DIRECT ACTING ON/OFF/REGULATING NAMUR SOLENOID VALVE MODEL 30318, 30318LW ROTEX retains all rights to this publication.

More information

SERVICE INSTRUCTIONS D TON

SERVICE INSTRUCTIONS D TON 1120 SOUTH CRYSTAL AVE * BENTON HARBOR MI PH: 269-925-7777 FAX: 269-925-6656 SERVICE INSTRUCTIONS D-51223 4 TON TO ASSEMBLE: 1. Check the handle set screw for tightness. CUSTOMER PRE-USE INSTRUCTIONS THE

More information

Oregon Fuel Injection

Oregon Fuel Injection Cummins PT Fuel Pump Diagnostic No Start, with no smoke 1. This could be caused by the fuel pump not turning or a seized gear pump. Remove the fuel supply hose and the fuel inlet fitting from the gear

More information

SAFETY MANUAL READ FIRST!

SAFETY MANUAL READ FIRST! 966-05-XX SAFETY MANUAL READ FIRST! IMPORTANT: READ THESE WARNINGS AND SAFETY PRECAUTIONS PRIOR TO INSTALLATION OR OPER- ATION. FAILURE TO COMPLY WITH THESE INSTRUC- TIONS COULD RESULT IN PERSONAL INJURY

More information

Installation and Service Manual for SRC25, SRC252, SRC50, SRC502, SRC75, SRC752

Installation and Service Manual for SRC25, SRC252, SRC50, SRC502, SRC75, SRC752 Rocking Piston Compressors Installation and Service Manual for SRC25, SRC252, SRC50, SRC502, SRC75, SRC752 Thank you for purchasing the Stratus SRC series rocking piston compressor. This instruction manual

More information

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 3 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 80. A JDA Global Company

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 3 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 80. A JDA Global Company OPERATION MANUAL 3 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 80 AIR-OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company CAUTIONS - READ FIRST CAUTION: Do not apply compressed air to the

More information

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product. Owner s Manual 1 Dear Customer, Thank you for purchasing this product. For optimum performance and safety, please read these instructions carefully. User Memo: Date of purchase: Dealer name: Dealer address:

More information

Operating Instructions & Parts Manual. Supa-Lite Lever Grease Gun. Model 48UJ77

Operating Instructions & Parts Manual. Supa-Lite Lever Grease Gun. Model 48UJ77 Operating Instructions & Parts Manual EN Supa-Lite Lever Grease Gun Model 48UJ77 PLEASE READ AND SAVE THESE INSTRUCTIONS. READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE

More information

User Manual for the ProFlow 1K Release: User Manual for the ProFlow 1K_Rev_A PVA Support Hub. User Manual for the ProFlow 1K

User Manual for the ProFlow 1K Release: User Manual for the ProFlow 1K_Rev_A PVA Support Hub. User Manual for the ProFlow 1K PVA Support Hub User Manual for the ProFlow 1K Collection of guides and pages for the operation and maintenance of the ProFlow 1K. Written By: Technical Writing 2017 support.pva.net Page 1 of 18 INTRODUCTION

More information

MODELS 9917, , 9946P and 9989 High Pressure Lubrigun Series A

MODELS 9917, , 9946P and 9989 High Pressure Lubrigun Series A MODELS 9917, 9917-57, 9946P and 9989 Series A NOTE: Pails and Drums shown for illustration only. not included with models. MAR - 2007 Section - A5 Page - 84 DESCRIPTION Models 9917, 9917-57, 9946P, and

More information

Table of Contents Visual Inspection and Neutralizing... 3 Disassembly

Table of Contents Visual Inspection and Neutralizing... 3 Disassembly 1 Table of Contents Visual Inspection and Neutralizing... 3 Disassembly... 3... 4... 4 Cleaning... 4 Inspection... 4 Reconditioning of Valve Seats... 5 Lapping Procedures... 5 Lapping Blocks... 5 Lapping

More information

SINGLE ACTION FLUID PUMP

SINGLE ACTION FLUID PUMP SINGLE ACTION FLUID PUMP MODELS 4490, 4491, 4492 S SERIES A Model 4492 (Stub Pump) Model 4491 (250-275 Gal) Model 4490 (16-55 Gal) Model A52347R-248 (250-275 Gal NOV - 2006 Section -A6 Page -63A Table

More information

Z100A Clinical Centrifuge

Z100A Clinical Centrifuge Z100A Clinical Centrifuge User Manual C0100-A Rev 2 August 2016 About This Manual This manual is designed to assist you in the optimal usage of your Labnet Z100A Clinical Centrifuge. The manual is available

More information

Owner s/operator s Manual

Owner s/operator s Manual Water Pump MP2533E2 Owner s/operator s Manual Completely read and understand this manual before using this product. Foreword This Owner s/ Operator s Manual is designed to familiarize the operator with

More information

Semi-automatic Thermal Sealer

Semi-automatic Thermal Sealer A Geno Technology, Inc. (USA) brand name Semi-automatic Thermal Sealer Cat. No. BT1901 1-800-628-7730 1-314-991-6034 info@btlabsystems.com Thanks for choosing BT Lab Systems Semi-automatic Thermal Sealer.

More information

MOREHOUSE INSTRUMENT COMPANY, INC. 60,000 LBS CAPACITY AIRCRAFT PART NUMBER SCALE S FORCE CALIBRATION PRESS PART NO.

MOREHOUSE INSTRUMENT COMPANY, INC. 60,000 LBS CAPACITY AIRCRAFT PART NUMBER SCALE S FORCE CALIBRATION PRESS PART NO. INDEX 1. GENERAL SPECIFICATION AND DRAWING 804000-03... 2 2. ASSEMBLY INSTRUCTIONS... 5 3. OPERATING INSTRUCTIONS... 6 4. MAINTENANCE INSTRUCTIONS... 7 5. CERTIFICATE OF CAPACITY LOAD TEST AND OVERLOAD...

More information

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1 TECHNICAL SERVICE MANUAL industrial heavy duty motor speed pumps SERIES 4076 AND 4176 SIZES hle, ate and ale SECTION TSM 710.1 PAGE 1 of 8 ISSUE B CONTENTS Introduction....................... 1 Safety

More information

Operation & Maintenance Manual For 4900 Series Pumps Bulletin 134

Operation & Maintenance Manual For 4900 Series Pumps Bulletin 134 For 340 West Benson Avenue Grantsburg, WI 54840 1-800-366-1410 715-463-5177 www.northern-pump.com Table of Contents Introduction... 3 Cautionary Statements... 5 Pump Installation... 6 Removal from Installation...

More information

OWNER S MANUAL REMOTE CONTROL, DUAL HEAD FOGGING SYSTEMS

OWNER S MANUAL REMOTE CONTROL, DUAL HEAD FOGGING SYSTEMS OWNER S MANUAL Sentinel II 5500 REMOTE CONTROL, DUAL HEAD FOGGING SYSTEMS Read all instructions carefully before starting the installation. Save this manual for future use. 2 OWNER S MANUAL SAFETY Always

More information

IN-LINE HYDRAULIC FLOW TESTER

IN-LINE HYDRAULIC FLOW TESTER SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Internet Address: http://www.powerteam.com Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031

More information

TBI /2012 TRAUMATIC BRAIN INJURY DEVICE

TBI /2012 TRAUMATIC BRAIN INJURY DEVICE USER MANUAL TBI 0310 6/2012 TRAUMATIC BRAIN INJURY DEVICE Page 1 of 26 Setting up the TBI 0310 Head Impactor The TBI 0310 Head Impactor when fully assembled has the following components: 1. Control box

More information

PosiTest. Pull-Off Adhesion Tester. INSTRUCTION MANUAL v PosiTest AT-M (manual) PosiTest AT-A (automatic)

PosiTest. Pull-Off Adhesion Tester. INSTRUCTION MANUAL v PosiTest AT-M (manual) PosiTest AT-A (automatic) PosiTest Pull-Off Adhesion Tester INSTRUCTION MANUAL v. 4.0 PosiTest AT-M (manual) PosiTest AT-A (automatic) Introduction The portable, hand-operated PosiTest Pull-Off Adhesion Tester measures the force

More information

TECHNICAL SERVICE MANUAL GENERAL PURPOSE JACKETED PUMPS SERIES 230 MODELS HX4, KK, LQ, Q, M, N

TECHNICAL SERVICE MANUAL GENERAL PURPOSE JACKETED PUMPS SERIES 230 MODELS HX4, KK, LQ, Q, M, N CONTENTS TECHNICAL SERVICE MANUAL GENERAL PURPOSE JACKETED PUMPS SERIES 230 MODELS HX4, KK, LQ, Q, M, N SECTION 2 BULLETIN TSM-230-V ISSUE A Special Information 2 Maintenance 2 Packed Pump Breakdown Drawing

More information

Forbidden Diesel Performance Ford 6.7L Powerstroke EGR Delete Instructions 6.7L EGR DELETE BY FORBIDDEN DIESEL PERFORMANCE. Page 1

Forbidden Diesel Performance Ford 6.7L Powerstroke EGR Delete Instructions 6.7L EGR DELETE BY FORBIDDEN DIESEL PERFORMANCE. Page 1 6.7L EGR DELETE BY FORBIDDEN DIESEL PERFORMANCE Page 1 WARNING REGARDING EMISSIONS LAWS Not legal for sale or use on pollution-controlled motor vehicles anywhere in the United States. Legal ONLY for off-road

More information

PRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV "BLADE MASTER" AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS

PRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV BLADE MASTER AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS PRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV.020112 "BLADE MASTER" AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS The "Blade Master is a high-volume, low-energy, (U.L. /C.S.A.,

More information

TDSscan10M Pocket TDS Tester Instruction Manual

TDSscan10M Pocket TDS Tester Instruction Manual TDSscan10M Pocket TDS Tester Instruction Manual BANTE INSTRUMENTS CO., LTD TDSscan10M Pocket TDS Tester 1 Thank you for selecting the TDSscan10M pocket TDS tester. This manual provides a step-by-step guide

More information

CAB TILT HYDRAULIC SYSTEM

CAB TILT HYDRAULIC SYSTEM OPERATION, MAINTENANCE and SERVICE INSTRUCTIONS CAB TILT HYDRAULIC SYSTEM WITH POWER-PACKER PUMP, CYLINDERS and LATCHES A division of Actuant Corporation 1-800-745-4142 1 www.powerpackerus.com Notice The

More information

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

SLR / SLR-S/N. Instruction Manual. Walrus America Inc SLR / SLR-S/N Instruction Manual Walrus America Inc 1. Installation and Connection 1.1. Pump Installation The pump should be sited in a well ventilated and frost-free position. The distance between pumps-motors

More information

SERVICE MANUAL Moyno Mag Drive Series Motorized Pumps with Magnetic Drives 331, 332, 333, 344 MODELS

SERVICE MANUAL Moyno Mag Drive Series Motorized Pumps with Magnetic Drives 331, 332, 333, 344 MODELS SERVICE MANUAL Moyno Mag Drive 500 300 Series Motorized Pumps with Magnetic Drives 331, 332, 333, 344 MODELS Section: Mag Drive 500 Pumps Page: 1 of 4 Date: January 2010 DESIGN FEATURES Housing: PVC or

More information

Product Guide: Series III Pump Control Board Set (RoHS)

Product Guide: Series III Pump Control Board Set (RoHS) revised 04/08/10 Description: The Series III Pump Control Board Set provides motor drive and pump control for a wide assortment of pumps from Scientific Systems, Inc. The assembly consists of two circuit

More information

MALCOM Table-Top Digital Viscometer Model PC-1TL Series

MALCOM Table-Top Digital Viscometer Model PC-1TL Series MALCOM Table-Top Digital Viscometer Model PC-1TL Series INSTRUCTION MANUAL MALCOMTECH INTERNATIONAL 26200 INDUSTRIAL BLVD. HAYWARD, CA 94545 USA TEL. (510) 293-0580 FAX. (510) 293-0940 WEB. www.malcomtech.com

More information