1 Primeroyal / Milroyal Critical Service HPD Liquid End Instruction Manual Manual No : Rev. : 00 Rev. Date : 08/2015

2 PRECAUTIONS The following precautions should be taken when working with metering pumps. Please read this section carefully prior to installation. Protective Clothing ALWAYS wear protective clothing, face shield, safety glasses and gloves when working on or near your metering pump. Additional precautions should be taken depending on the solution being pumped. Refer to Safety Data Sheets for the solution being pumped. Hearing Protection It is recommended that hearing protection be used if the pump is in an environment where the time - weighted average sound level (TWA) of 85 decibels is exceeded. (as measured on the A scale - slow response) Electrical Safety Remove power and ensure that it remains OFF while maintaining pump. DO NOT FORGET TO CONNECT THE PUMP TO EARTH / GROUND. Electric protection of the motor (Thermal protection or by means of fuses) is to correspond to the rated current indicated on the motor data plate. Liquid Compatibility Verify if the materials of construction of the wetted components of your pump are recommended for the solution (chemical) to be pumped. Pumps Water Primed All pumps are tested with water at the factory. If your process solution is not compatible with water, flush the Pump Head Assembly with an appropriate solution before introducing the process solution. Plumbing and Electrical Connections Always adhere to your local plumbing and electrical codes. Line Depressurization To reduce the risk of chemical contact during disassembly or maintenance, the suction and discharge lines should be depressurized before servicing. Over Pressure Protection To ensure safe operation of the system it is recommended that some type of safety / pressure- relief valve be installed to protect the piping and other system components from damage due to over-pressure. 2 Instruction Manual

3 Lifting This manual should be used as a guide only - Follow your company s recommended lifting procedures. It is not intended to replace or take precedence over recommendations, policies and procedures judged as safe due to the local environment than what is contained herein. Use lifting equipment that is rated for the weight of the equipment to be lifted. Instruction Manual 3

4 TABLE OF CONTENTS SECTION 1 - DESCRIPTION SPECIFICATIONS... 5 SECTION 2 - INSTALLATION UNPACKING SAFETY PRECAUTIONS MOUNTING PIPING CONNECTIONS General NPSH CONSIDERATIONS TYPICAL PIPING SECTION 3 - OPERATION PUMP START-UP PROCEDURE (VARIABLE STROKE PUMPS) RELIEF VALVE ADJUSTMENT SECTION 4 - MAINTENANCE DIAPHRAGM REPLACEMENT (FIGURE 2, SHEET 1 & 2) HYDRAULIC OIL REPLACEMENT MARS REFILL VALVE (400) RETURNING UNITS TO THE FACTORY RECOMMENDED SPARE PARTS ROUTINE PREVENTIVE MAINTENANCE HYDRAULIC OIL REPLACEMENT CHECK VALVE MAINTENANCE Disassembly Re-assembly CORRECTIVE MAINTENANCE Relief Valve Assembly SECTION 5 - LEAK DETECTION (PRESSURE SENSING SYSTEM) DESCRIPTION PRINCIPLE OF OPERATION SPECIFICATIONS SECTION 6 - INSTALLATION & OPERATION (PRESSURE SENSING SYSTEM) UNPACKING SAFETY PRECAUTIONS DISASSEMBLY / ASSEMBLY ELECTRICAL CONNECTIONS NEMA 4 PRESSURE SWITCH WIRING Wiring EXPLOSION PROOF PRESSURE SWITCH WIRING START-UP SECTION 7 - PARTS Instruction Manual

5 SECTION 1 - DESCRIPTION Milton Roy s High Performance Diaphragm (HPD) liquid end overcomes the Net Positive Suction Head (NPSH) restrictions associated with conventional disc diaphragm metering pumps. This is accomplished by a patented Mechanically Actuated Refill System (MARS) that eliminates the process side support plate. The MARS also does away with the need for field adjustment of the refill mechanism by automatically compensating for process liquid modifications. This, combined with removable check valves, makes the HPD an ideal choice for any process in which downtime is critical. The HPD features a diaphragm that is compatible with a wide range of process liquids and chemicals. The HPD liquid end is particularly suitable for pumping costly, aggressive or hazardous liquids without leakage. 1.1 SPECIFICATIONS Steady State Accuracy / Turndown Ratio: + 1% over 10:1 Turndown ratio. Liquid Temperature: +20 F to 250 F Minimum Suction Pressure: Minimum Discharge Back Pressure: Hydraulic Fluid: Ball Checks: Gear Lubricant 3 PSIA minimum (12 psi maximum vacuum). 35 psi above suction pressure. Mobile SHC-524 or Equivalent. Double ball checks in suction and discharge. SHC-634 or Equivalent. Instruction Manual 5

6 SECTION 2 - INSTALLATION 2.1 UNPACKING Pumps are shipped Free on Board (FOB) from the factory and the title passes to the customer when the carrier signs for receipt of it. The customer, therefore, must file damage claims with the carrier. The shipping crate should be carefully examined upon receipt from the carrier to be sure there is no obvious damage to the contents. Open the crate carefully, as there are sometimes accessory items fastened to the inside of the crate that may be lost or damaged. Examine all material inside crate and check against the packing list to be sure that all items are accounted for and undamaged. 2.2 SAFETY PRECAUTIONS When installing, operating, and maintaining an HPD pump, keep safety considerations foremost. Use proper tools, protective clothing, and eye protection when working on the equipment and install the equipment with a view toward ensuring safe operation. Follow the instructions in this manual and take additional safety measures appropriate to the liquid being pumped. Be extremely careful in the presence of hazardous substances, (e.g. corrosives, toxics, solvents, acids, caustics, flammables etc.). 2.3 MOUNTING The HPD liquid end is shipped already mounted to the appropriate pump. Mounting, therefore, is simply a matter of securing the pump to a safe, level surface. For further information on proper pump mounting, see the appropriate pump instruction manual. 2.4 PIPING CONNECTIONS General General piping instructions are given in the pump drive instruction manual. No reciprocating plunger pump can be expected to perform satisfactorily unless those recommendations are followed. Pay particular attention to plastic liquid ends, as these units are relatively fragile and can be damaged by the installation. For best results, avoid straining the liquid end by installing a very short section of flexible tubing between rigid, fixed piping and suction and discharge cartridges on plastic liquid ends. NOTE: Maximum safety and reliability may be ensured by protecting liquid ends and piping with an external relief valve installed in the system discharge line. 6 Instruction Manual

7 SECTION 2 - INSTALLATION 2.5 NPSH CONSIDERATIONS The HPD liquid end is far superior to conventional diaphragm liquid ends for suction lift and many other NPSH critical applications. It s patented diaphragm and advanced design refill mechanism give this liquid end truly high performance in these applications. For more NPSH information, refer to Milton Roy web site ( for aid in evaluating applications for this liquid end. 2.6 TYPICAL PIPING In order to adjust the HPD relief valve, it is necessary to have a pressure gauge and a shut OFF valve installed in the discharge line. The pressure gauge must have a higher range than the desired pump relief pressure, and should be installed as close to the pump discharge connection as possible. The shut OFF valve should be installed downstream of the pressure gauge. These items are not required for normal operation, but for ease of pump maintenance and adjustment, it is suggested that they be permanently piped into the line. Also see the instructions in the appropriate pump instruction manual for additional typical piping instructions. Instruction Manual 7

8 SECTION 3 - OPERATION 3.1 PUMP START-UP PROCEDURE (VARIABLE STROKE PUMPS) DO NOT RUN THE MOTOR UNTIL ALL START UP STEPS HAVE BEEN COMPLETED. YOU COULD DAMAGE THE PUMP IF YOU RUN THE MOTOR BEFORE ALL OF THE STEPS HAVE BEEN COMPLETED. IT MAY BE NECESSARY TO TEST THE MOTOR OFF THE PUMP TO INSURE PROPER DIRECTION AND OPERATION. THE MOTOR DIRECTION IS CRITICAL. WIRE THE MOTOR SO THAT IT ROTATES IN THE DIRECTION OF THE ARROW CAST ON THE MOTOR MOUNT FLANGE. CONSULT MANUFACTURER DOCUMENTATION FOR MOTOR START UP RECOMMENDATIONS. 1. Follow the motor mounting procedure before attempting to start your pumps. On some pumps, the motor is mounted at the factory. 2. Make the proper electrical connections to the motor per the manufacturer s recommendations. Make sure the motor is properly grounded. 3. Make sure that all of the mounting holes for the pump base are used to securely tighten the base to the mounting area. 4. Do not run the motor until ALL start up steps have been completed. 5. Remove the gear drive fill cap (the chamber closest to the motor). 6. Fill the gear drive chamber with appropriate gear lubricant (SHC-634). This oil was shipped with the pump. Fill this chamber so that the oil level is even with the midpoint of the sight glass. Do not overfill. 7. Remove the catchall chamber cover (closest to the process liquid end of the pump) revealing the plunger and bleed valve. Fill this chamber with hydraulic oil, ISO -32 (SHC-524). This oil was shipped with your pump, and is a lower viscosity compared to the gear oil. The hydraulic fluid must fill the catchall chamber so that the oil level is even with the midpoint of the sight glass. Do not overfill. NOTE: Two types of oils have been provided. They must be added at the proper location. 8. Remove all of the tubing connecting the air bleed valve (at the top of the displacement chamber behind the discharge check valve). There is a compression fitting at the point where the tubing enters the front catchall reservoir. Loosen the nut and remove the tubing from this fitting. There is a fitting connected to the air bleed valve that needs to be removed. Remove all air bleed valves from the top of the displacement chamber. 9. The displacement chamber must be filled with, ISO-32 (SHC-524) through the air bleed port. If pump equipped with leak detection see Section 5. IF THE DISPLACEMENT CHAMBER IS FILLED WITH THE PLUNGER FULLY REARWARD, THE DIAPHRAGM COULD RUPTURE AT START-UP. TO PROPERLY FILL THE DISPLACEMENT CHAMBER, THE PLUNGER MUST BE POSITIONED SO THAT IT IS TOP DEAD CENTER IN THE DISPLACEMENT CHAMBER. 10. With the plunger fully engaged in the displacement chamber (pump at TDC, Top Dead Center) adjust the stroke adjustment mechanism until the indicating needle reads 100%. Either turn the hand wheel on a micrometer, apply a 15-PSI supply signal for a Pneumatic, or apply a 20-mA signal for an Electronic actuator. In order to fill each displacement chamber and fully purge the air from the oil, rotate the motor either by hand (by removing the fan cover and spinning the fan by hand), or by rotating the motor electrically. The motor may be jogged by turning the power ON and OFF very quickly. (During this process watch for air bubbles escaping the oil) IT IS VERY IMPORTANT NOT TO ROTATE THE MOTOR AT HIGH SPEED, BECAUSE HYDRAULIC FLUID WILL BE FORCED FROM THE AIR BLEED PORT AT A VERY HIGH VELOCITY. 8 Instruction Manual

9 SECTION 3 - OPERATION 11. Rotate the motor shaft again so that the pump is back at TDC (fully extended plunger into the displacement chamber). Fill this chamber with ISO-32 oil and check that no air bubbles are present. 12. Replace the air bleed valve and tighten. Use a pipe thread sealant to seal the threads. Be very careful not to get any sealant into the displacement chamber air bleed port. Place the end of the tubing into the compression fitting and tighten the lock nut to secure the tubing. 13. On multiplex units, repeat these two steps for each pump to insure proper hydraulic fill in each displacement chamber. 14. Recheck the oil level in the catchall reservoir and install the cover, screws and lock washers. The gaskets have an adhesive backing that should be removed and the gaskets should be firmly attached to the covers using this adhesive. 15. Make sure that all oil fill caps are securely tightened to prevent oil leakage. WORKING ON THE PUMP LIQUID END. ALWAYS WEAR THE PROPER PROTECTIVE GEAR WHEN 16. Connect suction and discharge piping manifolds. Use the proper gaskets and tighten each flange per specification. Check that all connections are tight including the check valves, flanges, air bleed valves and the motor mount bolts. 17. Make sure the process bleeder barb, if so equipped, is tight. It is located on the front face of the pump directly under the discharge check valve. This fitting is used to purge any air that is trapped in the process liquid end. If this fitting is loose when you fill the pump, a stream of process fluid will come out and create a hazardous condition. 18. It is advisable to test the pump for proper operation by testing it with water before you use a process fluid. Now fill the process liquid ends with process fluid. TAKE ADDITIONAL SAFETY MEASURES APPROPRIATE TO THE LIQUID BEING PUMPED. BE EXTREMELY CAREFUL IN THE PRESENCE OF HAZARDOUS SUB-STANCES (CORROSIVES, TOXINS, SOLVENTS, ACIDS, CAUSTICS, AND FLAMMABLES). 19. Loosen each process bleeder barb, if so equipped, on each pump to bleed any air from the liquid end. Connect a hose to this barb and use caution if you are pumping a hazardous chemical. After all process liquid ends have been purged of air, you can tighten all bleeder barbs to prevent leakage. 20. Now the motor can be started if and only if all steps have been followed. A. For constant speed motors, adjust the stroke adjustment mechanism so that the indication needle reads 25-30%. Gradually increase the capacity adjustment mechanism and increase back-pressure to insure that the pump has time to purge all air from the system. B. For a variable speed drive, the motor should be run at a very slow speed between revolutions per minute, and the pump should have minimal process back pressure for initial start-up. Gradually increase the motor speed and increase back-pressure to insure that the pump time to purge all air from the system. NOTE: This concludes the start-up procedure. Please follow these steps to insure start-up success and reduce any risk of damage to the pump. Instruction Manual 9

10 SECTION 3 - OPERATION 3.2 RELIEF VALVE ADJUSTMENT THE PRESSURE RELIEF VALVE IS FACTORY SET TO OPEN AT A PRESSURE SLIGHTLY ABOVE THE PUMP MAXIMUM OPERATING DISCHARGE PRESSURE; NEVER SET THE VALVE AT ANY GREATER PRESSURE. All HPD liquid ends have a built in relief valve that allows hydraulic fluid to return to the hydraulic fluid reservoir if excessive pressure builds up in the discharge line. This effectively stops the pump from pumping, since the forward stroke of the piston will not displace the hydraulic fluid and force the diaphragm to flex. The HPD liquid end relief valve may be adjusted to operating conditions by the following procedure. Adjust the relief valve after first installing the pump and after any maintenance procedures. 1. A pressure gauge and shut OFF valve must be installed in the discharge line to complete this procedure. If the necessary equipment is not installed, refer to the Typical Piping instructions in Section Make sure shut OFF valve is open. Start pump and pump process liquid to drain or other safe point to establish proper pumping action. 3. Set capacity control at 30%. 4. Close shut OFF valve slowly ( dead head the pump) and closely watch the pressure increase on the pressure gauge. If pressure exceeds desired value, quickly open shut OFF valve to relieve pressure in line. 5. With shut OFF valve still closed, loosen relief valve adjusting screw located on top of valve until the maximum pressure gauge reading reaches and maintains the relief valve pressure setting desired. 6. After setting relief valve, make sure shut OFF valve is fully open. Remove pressure gauge from line or leave in place, as desired, and place pump in routine service. DURING PRESSURIZED PUMP OPERATION. NEVER OPEN THE AIR PURGE VALVE (IF EQUIPPED 0261) 7. The diaphragm head is equipped with an air bleed purge valve built in just below the discharge port. (Item 0350). The purpose of this device is to vent entrapped air from the diaphragm head during priming and start-up. This end of this fitting will accept flexible tubing in order to pipe OFF the solution to a nonhazardous location. Immediately after priming, the fitting should be tightened. KEEP HANDS AWAY FROM RECIPROCATING PLUNGER AND CROSSHEAD. DO NOT LEAVE PUMP OPERATING UNATTENDED WITH SHUT OFF VALVE CLOSED. EXCESSIVE PRESSURE CAN BUILD QUICKLY, POSSIBLY CAUSING SEVERE DAMAGE TO PUMP AND / OR PIPING. SINCE THE RELIEF VALVE IS NOT YET PROPERLY ADJUSTED, IT CAN NOT BE RELIED ON TO LIMIT EXCESSIVE PRESSURE BUILD-UP. BE SURE TO WATCH PRESSURE GAUGE VERY CAREFULLY AND OPEN SHUT OFF VALVE IMMEDIATELY IF EXCESSIVE PRESSURE DEVELOPS. 10 Instruction Manual

11 SECTION 4 - MAINTENANCE 4.1 DIAPHRAGM REPLACEMENT (FIGURE 2, SHEET 1 & 2) The HPD diaphragm is extremely durable and often lasts for many years of service. As a preventive measure, however, Milton Roy recommends that the diaphragms be replaced yearly to coincide with annual check valve replacement. The liquid end must be removed from the pump to replace the diaphragm. The following is the diaphragm replacement procedure: 1. Stop pump and relieve all pressure from system. Isolate the liquid end from all sources of process liquid with appropriate valving and purge liquid end of all process fluid. 2. Disconnect both the suction inlet and discharge outlet from the piping system. NOTE: Approximately one pint of oil will still be present in the contour plate area which will be released when the diaphragm is removed. Prepare your work area accordingly. 3. Remove the catchall cover and drain catchall of hydraulic oil by removing pipe plug at bottom of casing. 4. Completely loosen the piston rod retention nut (1750) located inside the catchall. 5. Disconnect all tubing that connects the liquid end to the pump body. NOTE: The liquid end is very heavy (150 lbs. or more). A hoist is required to move it. 6. Support liquid end with a hoist and unscrew nuts (980) that hold the displacement chamber (630) to the pump body. Pull liquid end and plunger assembly (2000) OFF, being careful to protect the plunger from damage. Carefully raise liquid end and plunger over catchall and pull plunger from liquid end, allowing hydraulic fluid to drain back into catchall. Pull plunger firmly but carefully, being careful not to bend or otherwise damage the plunger. 7. Remove relieve valve (1040) and refill valve (400) from displacement chamber. 8. Place liquid end, diaphragm head up (bolts (710) on top), on a bench or other clean, flat, and convenient working area. 9. Once the diaphragm head is adequately supported, the diaphragm head bolts (710) can be removed. Carefully pull the diaphragm head (700) away from the displacement chamber. The diaphragm (670) may pull OFF with the diaphragm head or remain with the displacement chamber. Remove diaphragm (670). (When equipped with leak detection (See Section 5) remove two diaphragms, leak detection ring A (8080), leak detection ring B (8081), and leak detection ring spacer (8082). Leak detection rings A, leak detection rings B, and leak detection ring spacer can be reused). 10. Clean all sealing surfaces and install new diaphragm (670). (When equipped with leak detection (See Section 5) install two diaphragms, leak detection ring A (8080), leak detection ring B (8081), and leak detection ring spacer (8082) removed previously. Apply a small amount of mineral oil between the diaphragms. Stacked diaphragms and rings may be aligned using the three small holes as a guide). NOTE: Apply anti-seize thread lubricant to the bolts. 11. Reinstall liquid end on catchall, using the bolts as a guide. NOTE: The bolt torque value stamped on the head only applies to the material grade supplied with the pump. Instruction Manual 11

12 SECTION 4 - MAINTENANCE 12. Torque bolts in sequence to one half of the final torque value stamped on the head. Follow the bolt torque pattern as stamped on the head. Repeat the torque sequence until bolts are tightened to final torque value. 13. Reconnect suction inlet and discharge outlet to piping system. Follow Section 5 if your pump is equipped with leak detection. 14. Fill the liquid end with hydraulic oil (refer to above INITIAL START-UP procedure). 4.2 HYDRAULIC OIL REPLACEMENT Inspect and replace hydraulic oil on same schedule as the pumps gear drive lubricant (or whenever diaphragm is replaced). Annual replacement is recommended. 4.3 MARS REFILL VALVE (400) The MARS refill valve (400) requires no periodic maintenance. Clean hydraulic oil is critical for proper operation. Strainer service: while replacing the hydraulic oil, it is also recommended that the hydraulic oil strainer be replaced. The strainer, (390) which screws into the displacement chamber can become fouled or clogged over time. Screw the valve back into the chamber. If the valve is damaged or broken, replace the entire assembly. 4.4 RETURNING UNITS TO THE FACTORY Pumps will not be accepted for repair without a Return Material Authorization, available from the factory or other authorized Customer Service Department. Pumps returned to the factory for repairs should be clearly labeled to indicate the liquid being pumped. Process liquid should be flushed from the pump liquid end before the pump is shipped. NOTE: Federal law prohibits handling of equipment that is not accompanied by an OSHA Safety Data Sheet (SDS). A completed SDS must be packed in the ship-ping crate with any pump returned to the factory. These safety precautions will aid the troubleshooting and repair procedure and preclude serious injury to repair personnel from hazardous residue in pump liquid end. A Safety Data Sheet must accompany all returns. 4.5 RECOMMENDED SPARE PARTS Be Prepared. To avoid delays in repairs, the following spare parts should be ordered for each pump: One Routine Preventive Maintenance Kit, which contains replacements for those parts which are subject to wear; specifically the ball checks, check valve seats, gaskets, and the hydraulic fluid strainer. Replacing these parts annually with an RPM kit can reduce the possibility of unexpected downtime and will help to extend pump life. Parts orders must include the following information: 1. Serial number (found on nameplate) 2. Model number (found on nameplate) 3. Quantity required 4. Part number 5. Part description Always include the serial and model numbers in all correspondence regarding the unit. 12 Instruction Manual

13 SECTION 4 - MAINTENANCE 4.6 ROUTINE PREVENTIVE MAINTENANCE BEFORE ANY MAINTENANCE, RELIEVE ALL PRESSURE FROM SYSTEM, ISOLATE LIQUID END FROM ALL SOURCES OF PROCESS LIQUID WITH APPROPRIATE VALVING, AND PURGE LIQUID END OF ALL PROCESS LIQUID. All inquiries on part order should be addressed to your local Milton Roy sales representative or sent to: HYDRAULIC OIL REPLACEMENT Inspect and replace hydraulic oil on the same schedule as the pump s gear drive lubricant (see the appropriate pump drive instruction manual for this information). Semiannual replacement is recommended, and can be scheduled to coincide with season oil changes. To replace the hydraulic oil: 1. Remove the catchall cover by unscrewing the four screws, which hold it on. 2. Place a container under the pump catchall to catch the oil and unscrew the catchall drain plug. 3. When oil has finished draining, make sure that the area around the drain hole is clean. Screw drain plug back in securely. 4. Fill the catchall to the top of the oil seal that surrounds the crosshead with new, clean oil. Use hydraulic oil or any good quality type A automobile transmission fluid. 5. Replace the catchall cover the screw firmly in place. NOTE: It is not necessary to purge the liquid end displacement chamber of oil during annual oil replacement. 6. Dispose of oil according to federal, state, or local codes that may apply. 4.8 CHECK VALVE MAINTENANCE Disassembly BEFORE PERFORMING ANY MAINTENANCE ON THE CHECK VALVES, RELIVE ALL PRESSURE FROM SYSTEM, ISOLATE LIQUID END FROM ALL SOURCES OF PROCESS LIQUID WITH APPROPRIATE VALVING, AND PURGE LIQUID END OF ALL PROCESS FLUID. After insuring that all system pressure has been relieved and that all hazardous process liquids have been flushed from the liquid end, disconnect both the suction inlet and discharge outlet from the system piping. 1. Loosen the retaining nut, then remove. Once disassembled, the O-rings should be discarded. 2. Check valves may be removed. A compressed O-ring provides the seal to the head. Inspect the balls carefully. If they are smooth, round and free of deposits or pits, then they are suitable for continued use. Examine the check valve seats. The area of the seat where it meets the ball (the un-chamfered side) must be in near perfect condition for continued use. Any imperfection visible on the seating surface (pits, erosion, cracks, or a ball shaped contour greater than deep) makes the seat unusable. If both the balls and seats are in good condition, then the length of time between parts replacement may be lengthened. If the balls and seats are severely damaged, then the length of time between parts replacement should be shortened Re-assembly 1. Replace O-ring on the check valves. Lubricate the O-rings and check valve threads before assembly. 2. Attach port adapter and tighten retaining nut. Instruction Manual 13

14 SECTION 4 - MAINTENANCE 4.9 CORRECTIVE MAINTENANCE Relief Valve Assembly The relief valve assembly operates in filtered hydraulic oil and should require maintenance only if unusual circumstances occur, such as if corrosive media contaminates the fluid. Assembly and disassembly is straightforward. Field servicing should be limited to inspection and cleaning only. Repairs of this critical component should only be carried out by an authorized Milton Roy repair facility. 14 Instruction Manual

15 SECTION 5 - LEAK DETECTION (PRESSURE SENSING SYSTEM) 5.1 DESCRIPTION (FIGURE 2, SHEET 1 & 2) Milton Roy s pumps are, by design, leakproof and durable. In some applications, however, added assurance is desired to protect the pump from hostile chemicals, or protect the process from contamination by hydraulic fluids. For these situations, Milton Roy has developed a highly reliable diaphragm rupture detection system. The diaphragm rupture detection system is an optional feature, available on the Critical Service line of metering pumps, which is used to detect and signal if a hole or tear occurs in one or both diaphragms. The system consists of two PTFE diaphragms separated by four leak detection rings (two A rings (8080) & two B rings (8081)). Pressure in the four leak detection rings between the diaphragms is monitored via a pressure gauge. A machined port in the displacement chamber at (5021) connects the diaphragms and rings with tubing, gauge, and or pressure switch. A low cracking pressure check valve (5000) and a bleed valve (5100) are located between the displacement chamber and the pressure gauge. 5.2 PRINCIPLE OF OPERATION The system consists of two separate diaphragms, four leak detection rings, leak detection ring spacer (8082), and a pressure gauge (5030) or switch (1250). During normal operation, the two diaphragms are pushed tightly together and are separated only around their outside edge by the rings. Because there is no fluid and very little air between the two diaphragms, the system does not experience pressure from the process when both diaphragms are intact. The pressure is therefore at atmospheric pressure, and the pressure gauge displays 0 psi. The rupture detection system senses process pressure only when one of the diaphragms rupture. In the event of a rupture in either diaphragm, fluid rushes into the rings, and the pressure at the ring rises rapidly to the pump s operating pressure. This pressure will be displayed directly on the pressure gauge for visual indication. An optional pressure switch is also available to shut down the pump or provide an alarm signal. The pressurized fluid trapped between the pressure gauge and the check valve can be relieved via the bleed valve after the pump is shut down and system pressure relieved. 5.3 SPECIFICATIONS Maximum Pressure Ratings: Same as pump rating. Diaphragms: PTFE Materials: Flow Rate: Accessories: Leak Detection Ring / Tubing: Steel 304SS or 316SS Derate flow by 5% on all pumps Pressure Gauge: 316SS liquid filled (Standard) Pressure Switch W/Gauge : NEMA 4 or Explosion Proof (optional) Instruction Manual 15

16 SECTION 6 - INSTALLATION & OPERATION (PRESSURE SENSING SYSTEM) The Diaphragm Rupture Detection System is usually shipped already mounted to the pump. Installation, therefore, is usually only a matter of piping in the pump, and wiring the pressure switch if one is provided. 6.1 UNPACKING Units are shipped Free on Board (FOB) factory and the title passes to the customer when the carrier signs for receipt of the unit. In the event that damages occur during shipment, it is the responsibility of the customer to notify the carrier immediately and to file a damage claim. Carefully examine the shipping crate upon receipt from the carrier to be sure there is no obvious damage to the contents. Open the crate carefully so accessory items fastened to the inside of the crate will not be damaged or lost. Examine all material inside crate and check against packing list to be sure that all items are accounted for and intact. 6.2 SAFETY PRECAUTIONS When installing, operating, and maintaining a Critical Service pump with Diaphragm Rupture Detection, keep safety considerations foremost. Use proper tools, protective clothing, and eye protection when working on the equipment and install the equipment with a view toward ensuring safe operation. Follow the instructions in this manual and take additional safety measures appropriate to the liquid being pumped. Be extremely careful in the presence of hazardous substances (e.g., corrosives, toxics, solvents, acids, caustics, flammables etc.). 6.3 DISASSEMBLY / ASSEMBLY (REFER TO DRAWING , FIGURE 2, SHEET 1 & 2) LOOSENING ANY HYDRAULIC CONNECTIONS OR OPENING ANY VALVES COULD CAUSE PROCESS LIQUID TO BE RELEASED UNDER PRESSURE. CAREFULLY DISCONNECT PUMP FROM ALL ELECTRICAL AND HYDRAULIC SERVICE BEFORE PERFORMING ANY MAINTENANCE. 1. After shutting down the pump and relieving system pressure, disconnect all hydraulic connections. 2. Drain the oil from the catchall. 3. Disassemble the diaphragm head from the pump body following the instructions in Section Remove diaphragms (670) and discard along with four leak detection rings (8080 and (8081), and leak detection ring spacer (8082). Items (8080, 8081, and 8082) can be reused if not damaged by process fluid. Refer to Figure 2, Sheet 2, Detail C as needed. IF THE PROCESS FLUID IS HYDROGEN PEROXIDE OR ANOTHER STRONG OXIDIZING AGENT, MINERAL OIL SHOULD NOT BE USED BETWEEN THE DIAPHRAGMS. SUBSTITUTE WITH A CHLOROTRIFLUOROETHYLENE POLY-MER FLUID SUCH AS FLOUROLUBE. 5. Clean all sealing surfaces and install new diaphragms (670), leak detection ring A (8080), leak detection ring B (8081), and leak detection ring spacer (8082), leak detection ring A (8080), leak detection ring B (8081) removed previously (Figure 2, Sheet 1, Detail C). Apply a small amount of mineral oil between the diaphragms. Stacked diaphragms and rings may be aligned using the three small holes as a guide. Make sure diaphragms (670) fit into pocket on diaphragm head (700). 16 Instruction Manual

17 SECTION 6 - INSTALLATION & OPERATION (PRESSURE SENSING SYSTEM) 6. Reassemble diaphragm head following Section Once the suction inlet and discharge outlets are connected to piping system mount the switch bracket (5090, Figure 2 Sheet 2) then the remaining components should be fitted finger tight and oriented as shown. NOTE: Check the flow direction arrow on the check valve. The check valve must be assembled with the arrow pointed toward the pressure gauge or pressure switch as shown in the figures. Improper operation will result if the check valve is not installed correctly. 8. Check all threaded and tube connections to make sure they are tight. IMPORTANT 9. Remove the pipe plug(s) and open the bleedvalve(s). Follow the oil fill and start up procedure in manual. 10. Leaving the bleed valve(s) open, run the pump at 100% capacity and normal operating pressure for 10 minutes. This procedure purges any excess air and oil from in between the diaphragms. If too much mineral oil was placed between the diaphragms in step 5, some will leak out from the bleed valve(s) at this point. Lubricant leakage is acceptable. 11. Close the bleed valve(s) and replace the pipe plug(s). The leak detector assembly is now complete. 12. Additional oil may need to be purged again. Return to step ELECTRICAL CONNECTIONS THIS SECTION ONLY APPLIES TO MODELS EQUIPPED WITH THE PRESSURE SWITCH ALARM OPTION. The diaphragm leak detection system can be equipped with a pressure switch which can be wired to activate an alarm or shut down the pump in the event of a diaphragm failure. This switch is either NEMA 4 (indoor / outdoor, weather and dust proof) or Explosion Proof (for hazardous locations). In both cases the switch relay is single-pole doublethrow (SPDT), normally open or normally closed and rated for 15 amps, 125/240/480 VAC resistive. 6.5 NEMA 4 PRESSURE SWITCH WIRING The switch terminals are accessed by removing the two screws retaining the cover and cover gasket. A 1/2 NPT conduit connection is provided in the switch enclosure Wiring Unscrew the switch cover to access the wiring connections. A 3/4 NPT conduit connection is provided in the switch enclosure. Replacing the cover hand tight (5 full threads engaged) is sufficient to maintain proper protection. Additional tightening may be required to fully engage the O-ring and seal enclosure for rain tight protection. Instruction Manual 17

18 SECTION 6 - INSTALLATION & OPERATION (PRESSURE SENSING SYSTEM) 6.6 EXPLOSION PROOF PRESSURE SWITCH ALWAYS WIRE IN ACCORDANCE WITH LOCAL OR NATIONAL CODES. BE SURE ALL LIVE SUPPLY CIRCUITS ARE DISCONNECTED BEFORE WIRING TO THE SWITCH. MAXIMUM RECOMMENDED WIRE SIZE IS #14 AWG. The three switch terminals are clearly labeled Com (common), NO (normally open), and NC (normally closed). A grounding screw is also provided. Keep wires as short as possible to prevent interference with the plunger and differential switch wheel inside the switch. Customer Connections 6.7 START-UP 1. Refer to the manual for pump installation and start-up instructions. 2. During the initial installation, following any disassembly of the leak detection system, or if the pump has not been operated for a prolonged period, a short break-in procedure for the leak detector system is required. On duplex pumps, be sure to follow directions on both sides of the pump. a. Open the bleed valve(s) on the leak detection system. b. Operate the pump at 100% capacity and normal system operating pressure. Air and a small amount of oil may leak from the bleed valve(s). NO (Blue) COM NC (Violet) (Black) c. After a minimum of ten minutes of operation, close the bleed valve(s). The break-in operation purges any air and excess oil which may be trapped in the intermediate ring(s). The leak detection system is now operational. NC COM NO Internal SPDT Switch Rated 15A, 120/240/480 VAC Figure 1. Pressure Switch Wiring Diagram IMPORTANT Connections must always be made through cable connectors which maintain the integrity of the NEMA 4 switch or Explosion Proof enclosure. 18 Instruction Manual

19 SECTION 7 - PARTS 1. Please refer to the Bill of Material and assembly for spare parts. 2. Use the drawing to identify the sequence for the part. 3. The sequence number is used on the drawing and Bill of Material. 4. Parts should be ordered by the Part Number listed in the Bill of Material. 5. Also reference the sequence number of the part, since component upgrades occur. Instruction Manual 19

20 20 Instruction Manual

21 Instruction Manual 21

22 ITEM NUMBER BILL OF MATERIAL FOR MCB2418GPCCDEAV6H311C522 MR SO # / PO MILROYAL C MODEL # MCB241 TAG # , PART NUMBER NOMENCLATURE QUANTITY U/I BARB,AIR BLEED 316/316LSS 1 EA 262 A OR -007 VITON 1 EA O RING VITON 1 EA AIR BLEED VALVE HI TEMP 1 EA PLUG, AIR BLEED VALVE 1 EA 352 V-112 POPPET O-RING / VITON STD. 1 EA STRAINER FITTING HPD 1 EA REFILL VALVE BODY 1 EA 420 L10626 BALL, 1/4 440C SS 1 EA SPRING MARS CS 1 EA FLATWASHER M4 ZINC PLT 1 EA RETAINING RING #RCLBHO0037STPA 1 EA DISP. CHMBR 116 SLEEVED 1 EA MARS BUTTON 1 EA SPRING, MARS BUTTON 1 EA POPPET MARS VALVE 1 EA WALDES RETAINING RING X EA PLUG 1/8 NPT SOCKET HEX HEAD 1 EA SOC HD SCR #10-24X1-1/2 STL 2 EA O-RING VITON / USE V EA CONTOUR PLATE 7.50 MILC BAR 1 EA DIAPHRAGM - GYLON X EA DIAPHRAGM HEAD 116 BAR ASTM A479 1 EA G7 SOC HD CAP SCR 1 1/4-7 X 5 1/2 12 EA WASHER, FLAT 1 1/4 NARROW 12 EA CAGE - 1-1/2 BALL CHECKS 316SS 4 EA O-RING, TFE ENC VITON,V EA SEAT - 1-1/2 BALL CHECKS 316SS 4 EA G7 BALL 1-1/2 316SS 4 EA CHECK VALVE BODY - 1-1/2 2 EA O-RING, TFE ENC VITON, V EA FLANGE WELD ASSY 1 600# VERT 2 EA 22 Instruction Manual

23 ITEM NUMBER PART NUMBER NOMENCLATURE QUANTITY U/I O RING NITRILE 70 DURO 1 EA SLEEVE, PLUNGER BORE 1.50 DIA 1 EA HEX HD SCR 1/2-13X1-1/4 ULTRA 5 EA HALF MOON STEEL MILROY HPD ALL 2 EA PLUNGER ADAPTER 7/8 HOLE CRS 1 EA GASKET 5-1/2ID LE TO DRIVE HSG 1 EA SPRING LOCK WASHER 5/8 18.8SS 4 EA HEX HD SCR 5/8-11X1-3/4STL GR2 4 EA HXPIPEBSHG 1X1/2 304SS 1 EA NIPTHRDSCH40 1/2X1-1/8 304SS 1 EA TEE3000#THRD 1/2 304SS 1 EA HXPIPEBSHG 1/2X1/4 304SS 1 EA MALE ELBOW 1/2 NPT X 3/8 TUBE 1 EA 1021 A MELBOW 1/4T 1/4P SS 1 EA 1030 C /8 316 SEAMLESS.035W 12 IN 1031 C /4 316 SEAMLESS.035W 24 IN RELIEF VALVE 50/2500 PSI 1 EA 1051 A MCONN 3/8T 1/4NPT SS 1 EA 1052 A MCONN 1/4T 1/8P SS 1 EA PLUNGER ASSEMBLY 1 1/2 1 EA MINERAL OIL-NOT FOR RESALE 1 OZ 4990 C /8 316 SEAMLESS.035W 24 IN CHECK VALVE 1/8TUBE 1/3PSI 316SS 1 EA TUBE CONN 1/8 TUBEX 1/8NPT 316SS 2 EA GAUGE, PRES, 2.5, ASHCRO, 2000PSI 1 EA PAN HD SCR #4-40X1/2 ZNCR 3 EA SPRING LOCK WASHER #4 18.8SS 3 EA 5033 C NUT SS 3 EA TEE 1/8NPT FEMALE 316SS 1 EA RED ADAPTER 1/4F X1/8M NPT 316SS 1 EA SUPPORT BRACKET,SWITCH / GAGE 1 EA HEX HD SCR 1/4-20X3/4 18.8SS 2 EA BLEED VALVE 1/8 NPT 316SS 1 EA LEAK DETECTION RING A 2 EA LEAK DETECTION RING B 2 EA SPACER RING 116 RUP. DET. 1 EA O-RING, TFE ENC VITON, EA Instruction Manual 23

24 ITEM NUMBER BILL OF MATERIAL FOR MCB2018JPCCCEAV6H311C522 MR SO # / PO MILROYAL C MODEL # MCB201 TAG # A/B, A/B, A/B, A/B PART NUMBER NOMENCLATURE QUANTITY U/I BARB,AIR BLEED 316/316LSS 1 EA 262 A OR -007 VITON 1 EA O RING VITON 1 EA AIR BLEED VALVE HI TEMP 1 EA PLUG, AIR BLEED VALVE 1 EA 352 V-112 POPPET O-RING / VITON STD. 1 EA STRAINER FITTING HPD 1 EA REFILL VALVE BODY 1 EA 420 L10626 BALL, 1/4 440C SS 1 EA SPRING MARS CS 1 EA FLATWASHER M4 ZINC PLT 1 EA RETAINING RING #RCLBHO0037STPA 1 EA DISP. CHMBR 116 SLEEVED 1 EA MARS BUTTON 1 EA SPRING, MARS BUTTON 1 EA POPPET MARS VALVE 1 EA WALDES RETAINING RING X EA PLUG 1/8 NPT SOCKET HEX HEAD 1 EA SOC HD SCR #10-24X1-1/4 STL 2 EA O-RING VITON / USE V EA CONTOUR PLATE 7.50 MILC BAR 1 EA DIAPHRAGM - GYLON X EA DIAPHRAGM HEAD 116 BAR ASTM A479 1 EA WASHER SAE HI STRENGTH 1 1/4 12 EA G7 SOC HD CAP SCR 1 1/4-7 X 5 1/2 12 EA CAGE - 1-1/2 BALL CHECKS 316SS 4 EA O-RING, TFE ENC VITON,V EA SEAT - 1-1/2 BALL CHECKS 316SS 4 EA G7 BALL 1-1/2 316SS 4 EA CHECK VALVE BODY - 1-1/2 2 EA O-RING, TFE ENC VITON, V EA 24 Instruction Manual

25 ITEM NUMBER PART NUMBER NOMENCLATURE QUANTITY U/I FLANGE WELD ASSY 1 600# VERT 2 EA O-RING VITON 1 EA SLEEVE, PLUNGER BORE 1.25 DIA 1 EA HEX HD SCR 1/2-13X1-1/4 ULTRA 5 EA HALF MOON STEEL MILROY HPD ALL 2 EA PLUNGER ADAPTER 7/8 HOLE CRS 1 EA GASKET 5-1/2ID LE TO DRIVE HSG 1 EA SPRING LOCK WASHER 5/8 18.8SS 4 EA HEX HD SCR 5/8-11X1-3/4STL GR2 4 EA HXPIPEBSHG 1X1/2 304SS 1 EA NIPTHRDSCH40 1/2X1-1/8 304SS 1 EA TEE3000#THRD 1/2 304SS 1 EA HXPIPEBSHG 1/2X1/4 304SS 1 EA MALE ELBOW 1/2 NPT X 3/8 TUBE 1 EA 1021 A MELBOW 1/4T 1/4P SS 1 EA 1030 C /8 316 SEAMLESS.035W 12 IN 1031 C /4 316 SEAMLESS.035W 12 IN RELIEF VALVE 50/2500 PSI 1 EA 1051 A MCONN 3/8T 1/4NPT SS 1 EA 1052 A MCONN 1/4T 1/8P SS 1 EA PLUNGER ASSEMBLY 1 1/4 1 EA MINERAL OIL-NOT FOR RESALE 1 OZ 4990 C /8 316 SEAMLESS.035W 12 IN CHECK VALVE 1/8TUBE 1/3PSI 316SS 1 EA TUBE CONN 1/8 TUBEX 1/8NPT 316SS 1 EA GAUGE,PRES,2.5,ASHCRO,2000PSI 1 EA PAN HD SCR #4-40X1/2 ZNCR 3 EA SPRING LOCK WASHER #4 18.8SS 3 EA 5033 C NUT SS 3 EA TEE 1/8NPT FEMALE 316SS 1 EA RED ADAPTER 1/4F X1/8M NPT 316SS 1 EA BRACKET, LEK DET, GAGE MCB 1 EA SCREW 3/8-16X3/4 SHCS, 18.8SS 2 EA BLEED VALVE 1/8 NPT 316SS 1 EA LEAK DETECTION RING B 2 EA LEAK DETECTION RING A 2 EA SPACER RING 116 RUP. DET. 1 EA O-RING, TFE ENC VITON, EA Instruction Manual 25

26 ITEM NUMBER BILL OF MATERIAL FOR MCB1418BPBCDEAV6ST33C5C2 MR SO # / PO MILROYAL C MODEL # MCB141 TAG # A/B/C/D PART NUMBER NOMENCLATURE QUANTITY U/I G7 BARB,AIR BLEED 316SS 1 EA 262 A OR -007 VITON 1 EA O-RING, TFE ENC VITON, V EA AIR BLEED VALVE HI TEMP 1 EA PLUG, AIR BLEED VALVE 1 EA 352 V-112 POPPET O-RING/VITON STD. 1 EA STRAINER FITTING HPD 1 EA REFILL VALVE BODY 1 EA 420 L10626 BALL, 1/4 440C SS 1 EA SPRING MARS CS 1 EA FLATWASHER M4 ZINC PLT 1 EA RETAINING RING #RCLBHO0037STPA 1 EA DISP. CHMBR MIL C 1 EA MARS BUTTON 1 EA SPRING, MARS BUTTON 1 EA POPPET MARS VALVE 1 EA WALDES RETAINING RING X EA 647 OS601 PLUG - 1/8 NPT, SOC HEX HD 1 EA SOC HD SCR #10-24X1-1/4 STL 2 EA O RING NITRILE 1 EA CONTOUR PLATE 4.50 MILC BAR 1 EA DIAPHRAGM -6 OD X.030 THK 2 EA DIAPHRAGM HEAD 72 L/D 1 EA G7 SOC HD SCR 7/8-9X4-1/2 ST XYLN 10 EA WASHER 7/8 AN 960 C ULTRA COAT 10 EA G7 CAGE 3/4 BALL, SLURRY SERVICE 4 EA SEAL.915ID 1.197OD.141THK 4 EA G7 SEAT,HARDENED INSERT ASSEMBLY 4 EA BALL 3/4 CERAMIC AD995 4 EA G7 CHECK VALVE BODY EA O-RING, TFE ENC VITON,M V EA FLANGE WELD ASSY 1/2 600#VERT 2 EA 26 Instruction Manual

27 ITEM NUMBER PART NUMBER NOMENCLATURE QUANTITY U/I HALF MOON STEEL MILROY HPD ALL 2 EA PLUNGER ADAPTER 7/8 HOLE CRS 1 EA GASKET 5-1/2ID LE TO DRIVE HSG 1 EA SPRING LOCK WASHER 5/8 18.8SS 4 EA SOC HD SCR 5/8-11X2 ULTRA COAT 4 EA 990 A BUSHING RED 1 X 1/4 SS 1 EA 1000 HN SS-4-HN 1 EA 1005 A TEE 1/4 SS 1 EA 1020 L11439 ELBOW 3/8ODTX1/4MPT 316SS 1 EA 1021 A MELBOW 1/4T 1/4P SS 1 EA TUBE MECH 3/8 ODX.035WALL 317L 18 IN TUBE MECH 1/4 ODX.035WALL 317L 24 IN RELIEF VLV ASSY PSIG 1 EA 1051 A MCONN 3/8T 1/4NPT SS 2 EA 1052 A MCONN 1/4T 1/8P SS 1 EA PLUNGER ASSEMBLY 7/8 1 EA MINERAL OIL-NOT FOR RESALE 1 OZ 4990 C /8 316 SEAMLESS.035W 12 IN CHECK VALVE 1/8TUBE 1/3PSI 316SS 1 EA TUBE CONN 1/8 TUBEX 1/8NPT 316SS 1 EA GAUGE,PRES,2.5,ASHCRO,2000PSI 1 EA PAN HD SCR #4-40X1/2 ZNCR 3 EA SPRING LOCK WASHER #4 18.8SS 3 EA 5033 C NUT SS 3 EA TEE 1/8NPT FEMALE 316SS 2 EA RED ADAPTER 1/4F X1/8M NPT 316SS 1 EA SUPPORT BRACKET,SWITCH / GAGE 1 EA SCREW 3/8-16X3/4 SHCS, 18.8SS 2 EA BLEED VALVE 1/8 NPT 316SS 1 EA LEAK DETECTION RING A 2 EA LEAK DETECTION RING B 2 EA MOD. SPACER RING SS 1 EA O-RING, TFE ENC VITON, V EA Instruction Manual 27

28 DRILL 1/4 O THRU AS BREATHER HOLE FOR PISTON SEALS INSTALLED BACK TO BACK OIL LEVEL REF DETAIL FOR HPD HOUSING Instruction Manual

29 ENLARGED SECTION Instruction Manual 29

30 BILL OF MATERIAL FOR MBH0918JPECCEAS6ST11C522 MR SO # / PO MILROYAL B MODEL # MBH091 TAG # , , ITEM NUMBER PART NUMBER NOMENCLATURE QUANTITY U/I HOUSING MIL B 1 EA OIL SEAL- CROSSHEAD 2 EA SQHDPLPIPE150#THRD 1 304SS 1 EA DISP CHMBR 9/16 LO FLO HPD STL 1 EA O-RING VITON 70 DURO 1 EA BODY MARS CS 1 EA CONTOUR PLT ASS Y CS-USE EA DIAPHRAGM LO FLOW HPD DBL DIA 2 EA DIAPHRAGM HEAD LOFLO HPD 6 D A479 1 EA G7 SOC HD SCR 1/2-13X3-1/4 XYLAN 8 EA FLAT WASHER SAE 1/2 NOM ULTRA 8 EA G7 STUD 3/8-16UNCX4-1/2 300SS 8 EA G7 GASKET TEFLON 3/8 BALL 106 HPD 10 EA G7 GUIDE 3/8 BALL 316SS HPD 4 EA G7 SEAT 3/8 BALL 316SS HPD 4 EA G7 BALL 3/8 316/316LSS 4 EA G7 FLANGE PORT ADAPTER WELD ASSY 2 EA G7 HEX NUT 3/8-16NC 18.8SS 8 EA G7 SPRING LOCK WASHER 3/8 316SS 8 EA O-RING NITRILE 70 DURO 1 EA STRAINER FITTING HPD 1 EA RELIEF VALVE ASSY MAX 1780 PSI 1 EA SPRING LOCK WASHER 5/16 Z PL 2 EA SOC HD SCR 5/16-18X2-3/4 ALY 2 EA BARB,AIR BLEED 316/316LSS 1 EA 1076 A OR -007 VITON 1 EA GASKET 1 EA PLUNGER ADAPTER 7/8 HOLE CRS 1 EA PLUNGER ASSY. 9/16 LO FLO HPD 1 EA 30 Instruction Manual

31 ITEM NUMBER PART NUMBER NOMENCLATURE QUANTITY U/I HEX HD SCR 3/8-16X1-1/4 ULTRA 4 EA ELL 1/2 NPT 3/4 ID TUBE NYLON 1 EA TUBING 1 OD X 3/4 ID-1/8 WALL 1 FT 4980 A MELBOW 1/8T X 1/8P SS 2 EA TUBE HEAD TO VALVE 1 EA CHECK VALVE 1/8TUBE 1/3PSI 316SS 1 EA TUBE, STRAIGHT, VALVE TO GAUGE 1 EA TUBE CONN 1/8 TUBEX 1/8NPT 316SS 1 EA GAUGE,PRES,2.5,ASHCRO,2000PSI 1 EA PAN HD SCR #4-40X1/2 ZNCR 3 EA SPRING LOCK WASHER #4 18.8SS 3 EA 5033 C NUT SS 3 EA RED ADAPTER 1/4F X1/8M NPT 316SS 1 EA TEE 1/8NPT FEMALE 316SS 1 EA SUPPORT BRACKET LOW FLOW HPD 1 EA HEX HD SCR 5/16-18X3/4 STL GR5 4 EA SPRING LOCK WASHER 5/16 Z PL 4 EA SUPPORT BRACKET LK DET MIL B 1 EA HEX HD SCR 1/4-20 X 5/8 316SS 2 EA 5096 C /4 FLAT WASHER SS 2 EA 5097 C /4-20 HEX NUT SS 2 EA BLEED VALVE 1/8 NPT 316SS 1 EA INTERMEDIATE RING MIL-BLOWFLOW 2 EA INTERMEDIATE RING MIL-BLOWFLOW 2 EA SPACER RING MIL-BLOW FLOW 1 EA O-RING VITON 70 DURO 1 EA Instruction Manual 31

32 BILL OF MATERIAL FOR MBH0718KPECCEAS6ST11C522 MR SO # / PO MILROYAL B MODEL # MBH071 TAG # , , ITEM NUMBER PART NUMBER NOMENCLATURE QUANTITY U/I HOUSING MIL B 1 EA OIL SEAL- CROSSHEAD 2 EA SQHDPLPIPE150#THRD 1 304SS 1 EA DISP CHMBR 7/16 LO FLO HPD STL 1 EA O-RING VITON 70 DURO 1 EA BODY MARS CS 1 EA CONTOUR PLT ASS Y CS-USE EA DIAPHRAGM LO FLOW HPD DBL DIA 2 EA DIAPHRAGM HEAD LOFLO HPD 6 D A479 1 EA G7 SOC HD SCR 1/2-13X3-1/4 XYLAN 8 EA FLAT WASHER SAE 1/2 NOM ULTRA 8 EA G7 STUD 3/8-16UNCX4-1/2 300SS 8 EA G7 GASKET TEFLON 3/8 BALL 106 HPD 10 EA G7 GUIDE 3/8 BALL 316SS HPD 4 EA G7 SEAT 3/8 BALL 316SS HPD 4 EA G7 BALL 3/8 316/316LSS 4 EA G7 FLANGE PORT ADAPTER WELD ASSY 2 EA G7 HEX NUT 3/8-16NC 18.8SS 8 EA G7 SPRING LOCK WASHER 3/8 316SS 8 EA O-RING NITRILE 70 DURO 1 EA STRAINER FITTING HPD 1 EA RELIEF VALVE ASSY MAX 1780 PSI 1 EA SPRING LOCK WASHER 5/16 Z PL 2 EA SOC HD SCR 5/16-18X2-3/4 ALY 2 EA BARB,AIR BLEED 316/316LSS 1 EA 1076 A OR -007 VITON 1 EA GASKET 1 EA PLUNGER ADAPTER 7/8 HOLE CRS 1 EA PLUNGER ASSY, 7/16 LO FLO HPD 1 EA HEX HD SCR 3/8-16X1-1/4 ULTRA 4 EA 32 Instruction Manual

Primeroyal / Critical Service HPD Liquid End Instruction Manual INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Primeroyal / Critical Service HPD Liquid End Instruction Manual INSTALLATION, OPERATION, AND MAINTENANCE MANUAL Primeroyal / Critical Service HPD Liquid End Instruction Manual INSTALLATION, OPERATION, AND MAINTENANCE MANUAL Please record the following data for file reference Tag Number(s): Model Number: Serial Number:

More information

High Performance Diaphragm Liquid End (HPD)

High Performance Diaphragm Liquid End (HPD) High Performance Diaphragm Liquid End (HPD) Milroyal B, C & D IOM Manual Manual No : 54146 Rev. : 00 Rev. Date : 10/2015 PRECAUTIONS The following precautions should be taken when working with metering

More information

Double Diaphragm with Pressure-Type Leak Detector. For MILROYAL, CENTRAC B And MAXROY

Double Diaphragm with Pressure-Type Leak Detector. For MILROYAL, CENTRAC B And MAXROY Double Diaphragm with Pressure-Type Leak Detector For MILROYAL, CENTRAC B And MAXROY Manual No : 54126 Rev. : 00 Rev. Date : 02/2016 PRECAUTIONS The following precautions should be taken when working with

More information

The following precautions should be taken when working with metering pumps. Please read this section carefully prior to installation.

The following precautions should be taken when working with metering pumps. Please read this section carefully prior to installation. MILROYAL D DISC DIAPHRAGM Low Flow Liquid End Manual No : 54248 Rev. : 00 Rev. Date : 11/2015 PRECAUTIONS The following precautions should be taken when working with metering pumps. Please read this section

More information

Milroyal D Disc Diaphragm Low Flow Liquid End

Milroyal D Disc Diaphragm Low Flow Liquid End Milroyal D Disc Diaphragm Low Flow Liquid End INSTRUCTION MANUAL Issued 08 10 TABLE OF CONTENTS.............................................. Section 1 Description...............................................

More information

Metallic Diaphragm Liquid End

Metallic Diaphragm Liquid End Metallic Diaphragm Liquid End INSTALLATION, OPERATION, AND MAINTENANCE MANUAL 339-0077-000 Issued 6/02 TABLE OF CONTENTS LIST OF ILLUSTRATIONS... 2 SECTION 1 FUNCTIONAL DESCRIPTION... 3 1.1 PHYSICAL DESCRIPTION...3

More information

SOLAROY 12 VDC Metering Pump

SOLAROY 12 VDC Metering Pump SOLAROY 12 VDC Metering Pump INSTALLATION, OPERATION, AND MAINTENANCE MANUAL MODEL NUMBER: SR-1PS-TC250 and SR-1PS-TC375 Manual #23858 Revision 2/2012 Precautions / Warnings: Proper fuse installation (to

More information

Pump Operating and Maintenance Manual - Models

Pump Operating and Maintenance Manual - Models Pump Operating and Maintenance Manual - Models 78-00111 - 78-0057 Thank you for purchasing the SDI Diaphragm Pump manufactured by Comet Pump. Comet produces quality products which are safe, efficient and

More information

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves MicroCoat System Operating Manual MC Series MC785M, MC785M-WF Spray Valves A NORDSON COMPANY Introduction The MicroCoat System provides precise lubrication control for metal stamping operations. The MC

More information

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico: MicroCoat System Operating Manual MC2 Series MC785, MC785-WF Spray Valves A NORDSON COMPANY US: 8-498-8865 UK: 8 585733 Mexico: 1-8-556-3484 Introduction The MicroCoat System provides precise lubrication

More information

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump ACHL Series Pump Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump Catalog: 02-9245ME February 2013 Model # Serial # Drawing # Order # Mfg. Date Table of Contents page

More information

Instruction Manual PN-Z PACKED PLUNGER PUMP. This Manual should be made available to person responsible for installation, maintenance and operation.

Instruction Manual PN-Z PACKED PLUNGER PUMP. This Manual should be made available to person responsible for installation, maintenance and operation. MILTON ROY INDIA (P) LTD Metering Pumps Instruction Manual PN-Z PACKED PLUNGER PUMP This Manual should be made available to person responsible for installation, maintenance and operation. PUMP MODEL: SERIAL

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM) INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM) IOM-1088 03-16 Model 1088 Vacu-Gard Blanketing Valve ISO Registered Company SECTION I I. DESCRIPTION AND SCOPE The Model 1088 Vacu-Gard is a tank blanketing

More information

Milroyal C. PD 3661 Effective 6/2009. MilRoyal C

Milroyal C. PD 3661 Effective 6/2009. MilRoyal C Milroyal C Milroyal C Pumps Milroyal C DUPLEX with HPD Liquid End GENERAL SPECIFICATIONS Drive Polar crank design all moving parts sub merged in oil. Front end scavenging The plunger always set to top

More information

6200 Series. Specifications. Fluid End Power End Models 6211, 6212, 6221, & 6222 Models 6241 & 6242 Part Material Part Material Part Material

6200 Series. Specifications. Fluid End Power End Models 6211, 6212, 6221, & 6222 Models 6241 & 6242 Part Material Part Material Part Material 5.2018.12.i 6200 Series Specifications The Flomore 6200 Series Pump line consists of a series of basic pump options all developed from a modular power unit. All units are pneumatically driven positive

More information

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions INSTALLATION AND MAINTENANCE INSTRUCTIONS IM-8-002-US October 2016 Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions These instructions should be read by the Company

More information

Fast-Flo Pump INSTRUCTIONS-PARTS LIST. Table of Contents 1:1 RATIO

Fast-Flo Pump INSTRUCTIONS-PARTS LIST. Table of Contents 1:1 RATIO INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. First choice when quality counts. 07 7 Rev. Z Supersedes W Includes Rev. Y changes

More information

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP Installation, Operation, & Maintenance Manual Welker Sampler Model GSS-4HP The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

Purging Air From Divider Block Lubrication Systems

Purging Air From Divider Block Lubrication Systems FROST ENGINEERING SERVICE Purging Air From Lubrication Systems A D I V I S I O N O F G E C S E Y S A L E S & S E R V I C E DESCRIPTION Divider block lubrication systems operate correctly only when all

More information

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS I. OPERATION & DESCRIPTION The Air / Hydraulic Injection Gun is a high-pressure tool that should be used with caution and according to these instructions. IMPORTANT: The Gun is 0,000 psi rated. Do not

More information

Type 644 and 645 Differential Pressure Pump Governors

Type 644 and 645 Differential Pressure Pump Governors Instruction Manual 644 and 645 Pump Governors Type 644 and 645 Differential Pressure Pump Governors Introduction Scope of Manual This instruction manual provides information on installation, adjustment,

More information

SINGLE ACTION FLUID PUMP

SINGLE ACTION FLUID PUMP SINGLE ACTION FLUID PUMP MODELS 4490, 4491, 4492 S SERIES A Model 4492 (Stub Pump) Model 4491 (250-275 Gal) Model 4490 (16-55 Gal) Model A52347R-248 (250-275 Gal NOV - 2006 Section -A6 Page -63A Table

More information

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood TABLE OF CONTENTS 1. General valve description and start-up... 1 2. Main valve maintenance... 1 3. Pilot maintenance... 5 4. Pilot

More information

Low Profile J Series Power Unit with Vane Pump

Low Profile J Series Power Unit with Vane Pump Low Profile J Series Power Unit with Vane Pump READ ALL INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING

More information

Fisher 644 and 645 Differential Pressure Pump Governors

Fisher 644 and 645 Differential Pressure Pump Governors Instruction Manual 644 and 645 Pump Governors Fisher 644 and 645 Differential Pressure Pump Governors Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Educational Services...

More information

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL Air Operated Double Diaphragm Pump M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL 0.5 I.O.M rev 05. 12/2015 INDEX Title Section Introduction.1 Safety.2 Warranty, General

More information

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance OPERATION: (4-2010) The Onyx DAO-PFC pinch valve is an open frame valve without housing enclosure and fails closed on loss of air. The actuator drives

More information

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

DeZURIK  BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT DeZURIK 20 144" BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT Instruction D10373 April 2017 Instructions These instructions provide information about the 20 (250 F2 model only) and the 24-144 BAW

More information

Instruction Manual. Series E7 Metering Pumps. For file reference, please record the following data:

Instruction Manual. Series E7 Metering Pumps. For file reference, please record the following data: Instruction Manual Series E7 Metering Pumps For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your

More information

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822 Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822 Statements: NIBCO High Performance Butterfly Valves, Series 6822 and 7822, have been designed

More information

Instructions for Installing and Operating Clark Reliance EA100 Series Levalarm

Instructions for Installing and Operating Clark Reliance EA100 Series Levalarm Section: R500.532F Bulletin: 532F Date: 7/1/2015 Supersedes: 532E Instructions for Installing and Operating Clark Reliance EA100 Series Levalarm This manual covers the following model numbers: EA100D,

More information

Instructions Parts List

Instructions Parts List Instructions Parts List : RATIO Fast Flo Pump Air operated piston transfer pump for low viscosity fluids. For professional use only. Only models that are EX certified are approved for use in European explosive

More information

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc. ARCHON Industries, Inc. Washdown Stations Models WD2010L, WD2010, WD2010H Installation / Operation / Maintenance Instructions 1 This manual has been prepared as an aid and guide for personnel involved

More information

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance OPERATION: (4-2010) The Onyx DAO-PFO pinch valve is an open frame valve without housing enclosure and fails open on loss of air. The actuator drives

More information

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance OPERATION: (4-2010) The Onyx DAO-ADA pinch valve is an open frame valve without housing enclosure and fails last position on loss of air. This actuator

More information

MOREHOUSE INSTRUMENT COMPANY, INC. 60,000 LBS CAPACITY AIRCRAFT PART NUMBER SCALE S FORCE CALIBRATION PRESS PART NO.

MOREHOUSE INSTRUMENT COMPANY, INC. 60,000 LBS CAPACITY AIRCRAFT PART NUMBER SCALE S FORCE CALIBRATION PRESS PART NO. INDEX 1. GENERAL SPECIFICATION AND DRAWING 804000-03... 2 2. ASSEMBLY INSTRUCTIONS... 5 3. OPERATING INSTRUCTIONS... 6 4. MAINTENANCE INSTRUCTIONS... 7 5. CERTIFICATE OF CAPACITY LOAD TEST AND OVERLOAD...

More information

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5 MODELS 282050, 282716 & 283513 AIR OPERATED CHASSIS PUMP SERIES A OWNER/OPERATOR MANUAL SPECIFICATIONS Airmotor effective dia. in. 2.5 Airinlet Material outlet 1/4 NPTF 1/4 NPTF Liquid to Air Pressure

More information

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators I & M Mark (/ ) 0 Wasson Road Cincinnati, OH 0 USA Phone --00 Fax -8-00 info@richardsind.com www.jordanvalve.com Installation & Maintenance Instructions for Mark Pressure Regulators Warning: Jordan Valve

More information

DODGE COOL LUBE 2 for Sleevoil Pillow Blocks Part Numbers , , ,

DODGE COOL LUBE 2 for Sleevoil Pillow Blocks Part Numbers , , , DODGE COOL LUBE for Sleevoil Pillow Blocks Part s 063487, 063488, 07889, 07890 These instructions must be read thoroughly before installing or operating this product. WARNING: To ensure the drive is not

More information

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J 1 IMPORTANT: READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING. PUMP DATA TYPE: MAT'L: WEIGHT: Air Operated Double Diaphragm Polypropylene or PVDF or Acetal PVDF (Polyvinylidene Fluoride)

More information

Installation, Operation, and Maintenance Manual. Welker Automatic Insertion Corrosion Coupon Device Model AID-1CC

Installation, Operation, and Maintenance Manual. Welker Automatic Insertion Corrosion Coupon Device Model AID-1CC Installation, Operation, and Maintenance Manual Welker Automatic Insertion Corrosion Coupon Device Model The information in this manual has been carefully checked for accuracy and is intended to be used

More information

Operating & Maintenance Manual For Steam Conditioning Valve

Operating & Maintenance Manual For Steam Conditioning Valve For Steam Conditioning Valve 1 Table of Contents 1.0 Introduction 3 2.0 Product description 3 3.0 Safety Instruction 4 4.0 Installation and Commissioning 5 5.0 Valve Disassembly 6 6.0 Maintenance 6 7.0

More information

Maintenance Instructions

Maintenance Instructions General Note These instructions contain information common to more than one model of Bevel Gear Drive. To simplify reading, similar models have been grouped as follows: GROUP 1 Models 11, 0, 1,, (illustrated),,

More information

Full View Flow Indicator

Full View Flow Indicator Full View Flow Indicator Threaded and Flanged Process Connection Installation / Operation / Maintenance Manual P.O. Box 1116 Twinsburg, OH 44087 Phone: 330/405-3040 Fax: 330/405-3070 E-mail: view@ljstar.com

More information

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P MANUAL NUMBER P-EFS-1 MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P TRAC Regulator Company Inc. 160 South Terrace Avenue Mount Vernon, New York USA 10550-2408 Phone: (914)

More information

Industrial Turbo Meters, Sizes 2" through 6"

Industrial Turbo Meters, Sizes 2 through 6 Industrial Turbo Meters Sizes 2" through 6" TUR-UM-00530-EN-19 (October 2014) User Manual Industrial Turbo Meters, Sizes 2" through 6" User Manual CONTENTS Scope of the Manual 5 Specifications 5 Product

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL MODEL 4D-200 REDUCED PRESSURE PRINCIPLE (RPZ) & MODEL 4D-700 REDUCED PRESSURE DETECTOR ASSEMBLY (RPDA) BACKFLOW PREVENTERS 2 ½ 10 Conbraco Industries Inc.

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Automatic Insertion Heated Regulator High Voltage Model IHRA-4SS-220/230 100 or more inch insertion length The information in this manual has been

More information

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION: DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION: These instructions are provided to familiarize the user with the seal and its use. The instructions must be read carefully

More information

Installation and Operation Manual

Installation and Operation Manual Industrial Process Installation and Operation Manual Advantage Actuator 2.0 Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health and safety...2 Transportation

More information

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air ORIGINAL INSTRUCTIONS Form No.1000458 5 SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet

More information

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve Technical Bulletin TB-ACV-LFF11RFP LEAD FREE * LFF11RFP Flood Protection Shut Down Valve Installed upstream of Reduced Zone Backflow Preventer. Normally Open Valve - Closes when continuous discharge from

More information

Refinery Supply Company, Inc.

Refinery Supply Company, Inc. Refinery Supply Company, Inc. OPERATING INSTRUCTIONS Super Pressure Dead Weight Tester Catalog No. 35260 Serving the Oil & Gas Industry since 1923 9133-A East 46th Street Tulsa, Oklahoma 74145-4823 Voice

More information

SERVICE INSTRUCTIONS. Transfer Pump

SERVICE INSTRUCTIONS. Transfer Pump TM TM SERVICE INSTRUCTIONS Transfer Pump 6799 DESCRIPTION Model 6799 is an air operated, self-priming, piston type transfer pump designed to transfer gasoline or diesel fuel at 30 gpm or oils up to SAE

More information

Welker Jet Top Entry Control Valve

Welker Jet Top Entry Control Valve Installation, Operation, & Maintenance Manual WJTECV-001.02 Welker Jet Top Entry Control Valve The information in this manual has been carefully checked for accuracy and is intended to be used as a guide

More information

I N S T R U C T I O N M A N U A L

I N S T R U C T I O N M A N U A L I N S T R U C T I O N M A N U A L M E T E R I N G P U M P S LINC84T-17, 18 & 20 Series Chemical Metering Pump Pneumatic Plunger T A B L E O F C O N T E N T S Contents - 84T-17, -18 & -20 Pump Manual...

More information

INSTALLATION AND SERVICE MANUAL FOR TURBO-CARB HIGH CAPACITY CARBONATOR

INSTALLATION AND SERVICE MANUAL FOR TURBO-CARB HIGH CAPACITY CARBONATOR Please refer to the Lancer web site (www.lancercorp.com) for information relating to Lancer Installation and Service Manuals, Instruction Sheets, Technical Bulletins, Service Bulletins, etc. INSTALLATION

More information

Railroad Ball Valves Series 5REB3

Railroad Ball Valves Series 5REB3 Railroad Ball Valves Series 5REB3 4" (DN 00) Installation, Maintenance and Operating Instructions IMO-R4 /05 IMO-R4 Table of Contents GENERAL.................................... 3. Scope of the Manual........................

More information

1/2" AIR DRIVEN DIAPHRAGM PUMP

1/2 AIR DRIVEN DIAPHRAGM PUMP 1/2" DRIVEN DIAPHRAGM PUMP OPERATION AND SERVICE GUIDE O-1225D NOV. 2008 Page 1 of 6 Refer to Bulletin P-605, Parts List P-9151 DRIVEN, DOUBLE DIAPHRAGM PUMP MANUAL Congratulations on purchasing one of

More information

Installation and Operating Manual

Installation and Operating Manual Installation and Operating Manual L-Series Vacuum Pumps Models L/H400C - L/H630C INSTALLATION & OPERATING MANUAL L/H-SERIES SINGLE STAGE ROTARY VANE VACUUM PUMPS L/H400C-L/H630C Please read the manual

More information

CUSTOM COMBINATION AIR VALVE

CUSTOM COMBINATION AIR VALVE INSTALLATION / OPERATION / MAINTENANCE CUSTOM COMBINATION AIR VALVE INTRODUCTION This manual will provide you with the information to properly install and maintain this valve to ensure a long service life.

More information

SAE STANDARD BOLT ASSEMBLY NUMBER 60020_IR4 INSTALLATION AND OPERATIONS MANUAL

SAE STANDARD BOLT ASSEMBLY NUMBER 60020_IR4 INSTALLATION AND OPERATIONS MANUAL SAE STANDARD BOLT ASSEMBLY NUMBER 60020_IR4 INSTALLATION AND OPERATIONS MANUAL CONTENTS Important! Read Carefully... 1 Safety and Warnings... 2 Warning Rotating Equipment Hazard... 2 Warning Pinch Point

More information

Pilot-Operated Regulators

Pilot-Operated Regulators Fisher Controls Instruction Manual Type 1098-EGR & 1098H-EGR Pilot-Operated Regulators R May 1987 Form 5084 Contents Introduction................................... 2 Scope of Manual..............................

More information

OPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

OPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS OPERATION MANUAL 2 METALLIC PUMP (CLAMPED) PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF50 AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models DUCTILE Models 316 S.S. Models A JDA Global Company CAUTIONS - READ

More information

MERIDIAN, 2 or 3 PIECE, TRUNNION MOUNTED BALL VALVES

MERIDIAN, 2 or 3 PIECE, TRUNNION MOUNTED BALL VALVES INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS MERIDIAN, 2 or 3 PIECE, TRUNNION MOUNTED BALL VALVES Size Range 2 48 ASME Classes 150-2500 *It is recommended that the valve installer is familiar with

More information

Fisher D2T FloPro Control Valve

Fisher D2T FloPro Control Valve Instruction Manual D2T FloPro Valve Fisher D2T FloPro Control Valve Contents Introduction... 1 Scope of Manual... 1 Description... 1 Educational Services... 2 Specifications... 3 Installation... 3 Setting

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Flanged Liquid Sampler Model LSS-1F Drawing No.: AD478BF.1 Manual No.: IOM-140 The information in this manual has been carefully checked for accuracy

More information

Levalarm Gold. Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016

Levalarm Gold. Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016 Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016 Levalarm Gold STORAGE AND HANDLING The Reliance Levalarm Gold meets or exceeds all applicable specifications when shipped from

More information

Crispin Valves Operating Guide. Crispin

Crispin Valves Operating Guide. Crispin Crispin Valves Operating Guide Crispin Since 1905 Crispin Multiplex Manufacturing Co. 600 Fowler Avenue Berwick, PA 18603 1-800-AIR-VALV T: (570) 752-4524 F: (570) 752-4962 www.crispinvalve.com sales@crispinvalve.com

More information

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual Manual No. 5AOP-OM1-2 Val-Matic Air / Oil Hydraulic Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION...

More information

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation Deluge Valve DV-5 Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation GeneralDescription The Model DV-5 Deluge Valve (described in Technical

More information

Welker Automatic Insertion Diffusing Probe Model AIP-3DP

Welker Automatic Insertion Diffusing Probe Model AIP-3DP Installation, Operation, and Maintenance Manual Welker Automatic Insertion Diffusing Probe Model AIP-3DP The information in this manual has been carefully checked for accuracy and is intended to be used

More information

GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL PLEASE RECORD THE FOLLOWING DATA (Information is located on the product label or packing slip) Model Number: Date Code: Installation Date: Installation

More information

IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation.

IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation. Industrial Turbo Meters Sizes 2" through 6" Installation & Operation Manual IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation. BadgerMeter,Inc. IOM-003-15 Part No.

More information

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. DISPLACEMENT PUMP 308190 Rev. K 3000 psi (210 bar) MAXIMUM WORKING PRESSURE Model

More information

Instruction Manual PN-K PACKED PLUNGER PUMP. This Manual should be made available to person responsible for installation, maintenance and operation.

Instruction Manual PN-K PACKED PLUNGER PUMP. This Manual should be made available to person responsible for installation, maintenance and operation. MILTON ROY INDIA (P) LTD Metering Pumps Instruction Manual PN-K PACKED PLUNGER PUMP This Manual should be made available to person responsible for installation, maintenance and operation. PUMP MODEL: SERIAL

More information

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet) Flow Control 500a DESCRIPTION The Viking 1-1/2 is a quick opening, differential type flood valve with a spring loaded rolling diaphragm clapper. The can be used to facilitate manual or automatic on/off

More information

Model Table of Contents. SERVICE & OPERATING MANUAL Original Instructions. Instructions Sheet:

Model Table of Contents. SERVICE & OPERATING MANUAL Original Instructions. Instructions Sheet: SERVICE & OPERATING MANUAL Original Instructions Instructions Sheet: 670989 Model 8324 Table of Contents Engineering Data and Temperature Limitations... 1 Performance Curve... 2 Dimensions... 3 Metric

More information

4 - Way Control 4 - Way Control 4 - Way Control with lock

4 - Way Control 4 - Way Control 4 - Way Control with lock INSTALLATION / OPERATION / MAINTENANCE 1. DESCRIPTION MODEL 0-02 (Full Internal Port) Powertrol Valve This manual contains information for installation, operation and maintenance of the Cla-Val Co. 0-02

More information

Material Specifications

Material Specifications 5.2012.12.b 6200 Series Specifications The Flomore 6200 Series Pump line consists of a series of basic pump options all developed from a modular power unit. All units are pneumatically driven positive

More information

Model 8329 Table of Contents

Model 8329 Table of Contents SERVICE & OPERATING MANUAL Original Instructions Instructions Sheet: 670991 Model 8329 Table of Contents Engineering Data and Temperature Limitations... 1 Performance Curve... 2 Dimensions... 3 Metric

More information

BLACKMER BYPASS VALVES

BLACKMER BYPASS VALVES BLACKMER BYPASS VALVES INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EBSRAY MODEL: RV18 RV18CBS2, RV18CBS3, RV18VRS10, RV18VRS14, RV18VRS19 967020 INSTRUCTIONS NO. 551-E00 Section Effective Replaces

More information

PV4 - Compact Shut Off Style Pig Valve IOM - Installation, Operation & Maintenance

PV4 - Compact Shut Off Style Pig Valve IOM - Installation, Operation & Maintenance ACECO Valve P.O. Box 9 Mounds, Oklahoma 74047 PV4 - Compact Shut Off Style Pig Valve IOM - Installation, Operation & Maintenance Doc. No.: IOM-PV4-.0 Date: 6/0-00 Revision: A Contents: Installation Operation

More information

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications Page 1 of 11 1. DESCRIPTION The Viking Model F-2 Dry Pipe Valve is a latching differential valve used to separate the water supply from the dry pipe sprinkler system. The valve combines a positive latching

More information

Model DF233 Control Valve

Model DF233 Control Valve Figure 1 DF233 Control Valve TABLE OF CONTENTS Introduction 2 Body and Packing Reassembly 7 Specifications 3 Fail Closed Actuator Reassembly 8 Valve Sizes 3 Fail Open Actuator Reassembly 9 Unpacking 4

More information

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 ) I & M Mark 8 Series 0 Wasson Road Cincinnati, OH 4509 USA Phone 5-5-5600 Fax 5-8-005 info@richardsind.com www.jordanvalve.com Installation & Maintenance Instructions for Mark 8 Control Valves (-/ - ) Warning:

More information

INSTRUCTION AND REPAIR MANUAL MODELS 341A, 342A AND 344A 6

INSTRUCTION AND REPAIR MANUAL MODELS 341A, 342A AND 344A 6 SECTION 6 ITEM 0 DATED JUNE 1998 SUPERSEDES ITEMS 1, 2, DATED MARCH 1992 INSTRUCTION AND REPAIR MANUAL MODELS 1A, 2A AND A 6 NOTE This repair manual is applicable to pump Models 1A, 2A and A. All photos

More information

TITAN FLOW CONTROL, INC.

TITAN FLOW CONTROL, INC. PREFACE: TITAN FLOW This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI)Full Body Swing Check Valves. To ensure efficient and safe

More information

Dodge Cool Lube 2 for Sleevoil Pillow Blocks Part Numbers , , ,

Dodge Cool Lube 2 for Sleevoil Pillow Blocks Part Numbers , , , Dodge Cool Lube for Sleevoil Pillow Blocks Part Numbers 063487, 063488, 07889, 07890 These instructions must be read thoroughly before installation or operation. This instruction manual was accurate at

More information

mroy Series Hydraulic Diaphragm Metering Pumps

mroy Series Hydraulic Diaphragm Metering Pumps mroy Hydraulic Diaphragm Metering Pumps The mroy series of metering pumps have provided users with high performance and reliability since its introduction in 1962. Enhanced and improved over the years,

More information

TITAN FLOW CONTROL, INC.

TITAN FLOW CONTROL, INC. PREFACE: This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) Wafer Style, Dual Plate Check Valves. To ensure efficient and safe operation

More information

ROOTS Meters Series B3 Meter Models 8C175-56M175

ROOTS Meters Series B3 Meter Models 8C175-56M175 ROOTS Meters Series B3 Meter Models 8C175-56M175 Refer to IOM-B3 for Complete Instructions IS:B3 3.03 RECEIVING, HANDLING AND STORAGE ROOTS rotary positive displacement gas meters are precision measurement

More information

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

HIGH PRESSURE CONTROL VALVE PISTON BALANCED PISTON BALANCED All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be

More information

Installation Operation Maintenance ADDENDUM

Installation Operation Maintenance ADDENDUM Installation Operation Maintenance ADDENDUM Bulletin #: PS-IOM-HYPO2-0111-A FACTORY SERVICE POLICY If you are experiencing a problem with your Pulsafeeder pump, first review the IOM, and consult the troubleshooting

More information

Model DF269 Control Valve

Model DF269 Control Valve Figure 1 DF269 Control Valve TABLE OF CONTENTS Introduction 2 Fail Open Actuator Disassembly 6 General 2 Body and Packing Reassembly 7 Scope 2 Fail Closed Actuator Resassembly 8 Specifications 3 Fail Open

More information

TECHNICAL DATA 1-1/2 (dn40)

TECHNICAL DATA 1-1/2 (dn40) July 1, 2011 Deluge Valves 209a DESCRIPTION The Viking Model E-3 1-1/2 Deluge Valve is a quick-opening, differential type flood valve with a rolling diaphragm clapper. The deluge valve is used to control

More information

Pressure Sensor No Series

Pressure Sensor No Series Sales Manual Section 335 PRODUCT SPECIFICATION 84372 SERIES Pressure Sensor No. 84372-Series GENERAL DESCRIPTION The patented* No. 84372-Series Pressure Sensor contains a weatherproof, snap-acting valve

More information

Pressure Relief Valve Maintenance Manual

Pressure Relief Valve Maintenance Manual Technical Manual 1098T Pressure Relief Valve Maintenance Manual Farris Engineering Division of Curtiss-Wright Flow Control Corporation TABLE OF CONTENTS - Manual Revision 0 Introduction & Safety Tips...

More information

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 ) I & M Mark 8 Series 30 Wasson Road Cincinnati, OH 4509 USA Phone 53-533-5600 Fax 53-8-005 info@richardsind.com www.jordanvalve.com Installation & Maintenance Instructions for Mark 8 Control Valves (/ -

More information

OPERATING AND MAINTENANCE MANUAL

OPERATING AND MAINTENANCE MANUAL Series 2200 Series 2220 Engineered Performance TABLE OF CONTENTS INTRODUCTION 1 About the Series 2200/ 2220 Valve 1 Identifying the valves 1 1.0 VALVE INSTALLATION AND START-UP 2 2 0 VALVE MAINTENANCE

More information