1 MILTON ROY INDIA (P) LTD Metering Pumps Instruction Manual PN-K PACKED PLUNGER PUMP This Manual should be made available to person responsible for installation, maintenance and operation. PUMP MODEL: SERIAL NO: CAPACITY: LPH: PRESSURE: No 4, Rajarajan Street, Visalakshi Nagar, Ekkaduthangal, Chennai , India. Telephone: Fax: Web: Issue Date: 07/2010 1
2 TABLE OF CONTENTS Page No WARRANTY 3 IMPORTANT SAFETY INSTRUCTION 4 QUICK START GUIDE INTRODUCTION 1.1 General Description Principles of Operation Technical Details INSTALLATION 2.1 Unpacking Storage / Idle Service Mounting Electrical Installations Piping START UP LUBRICATION SCHEDULE MAINTENANCE Method of changing Gland Packing BASIC PARTS TROUBLE SHOOTING 20 2
3 METERING PUMP PRODUCTS TWELVE MONTH LIMITED WARRANTY Milton Roy India private Limited Company warrants its metering pump product against defects in workmanship or material for one year under normal use from the date of shipment form our warehouses as indicated in our warranty certificate. All obligations and liabilities under this warranty are limited to refunding, repairing or replacing (at our option) f.o.b, our plant, such allegedly defectives units are returned to our plant, carrier charges prepaid. Repairs or replacement are made subject to factory inspection of returned items. This warranty does not extend to damage by corrosion or atmosphere. The materials of construction offered are recommendations subject in all cases to verification and acceptance by the customer. These recommendations, based on previous company experience and best available information s, do not constitute guarantees against wear and chemicals action. Expressly excluded from this warranty are defects caused by misuse, abuse or improper application/installation, employment or operation of the unit. Expendable items and damage resulting from unauthorized repair are not covered by this warranty. No liability for consequential damage or reinstallation labour is accepted. Milton Roy India Private Limited will not assume responsibility for contingent liability for alleged failure of its products. RETURNING PUMPS TO THE FACTORY Pumps will not be accepted for repair without a written consent from the Factory Service Department. Pumps returned to the Factory for repairs should be clearly labeled to indicate the liquid being pumped. Process liquid should be flushed from the pump liquid end and oil should be drained from the pump housing before the pump is shipped. NOTE: These safety precautions will aid the troubleshooting and repair procedure and preclude serious injury to repair personnel from hazardous residue in pump liquid end. All inquiries or parts orders should be addressed to your local Milton Roy India (P) Ltd., representatives or sent to: MILTON ROY INDIA (P) Ltd., NO.: 4, RAJARAJAN STREET, VISALAKSHI NAGAR EKKADUTHANGAL, CHENNAI PHONE NO.: (044) FAX NO.:
4 IMPORTANT SAFETY INSTRUCTIONS WARNING WARNING WHEN INSTALLING, CALIBRATING, OR OPERATING THIS ACTUATOR, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE RISK OF FIRE, ELECTRIC SHOCK, AND PERSONAL INJURY. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DEATH OR SERIOUS INJURY. Read all instructions before installation, calibration, or operation GENERAL SAFETY CONSIDERATIONS - Read this manual carefully. - Installation, calibration, and maintenance should be performed by trained and qualified personnel. Personnel should be familiar with the precautions required in working with hazardous voltages which exist inside the actuator. Personnel should also be adequately trained on any hazards inherent in the chemicals used in the metering pump. - Always wear protective clothing including gloves and safety glasses when working on or near chemical metering pumps. - Follow directions and warnings provided with the chemicals from the chemical manufacturer. User is responsible for determining the hazards associated with the chemicals being pumped and using the proper safety gear and procedures. - Hazardous voltages are present when cover is removed. Disconnect power when installing or servicing this unit. - Unit must be properly grounded. - Conform to local codes in wiring this equipment. - Pump must be adequately rated if it is to be used in a hazardous location. See product data plate for rating information. This rating must not be exceeded under any circumstances. To prevent ignition of hazardous atmospheres, cover must be tight while circuits are energized. - In order to comply with the requirements of agency approvals (see data plate), specifications for conduit connections, wire gauge and type, fastener torque ratings, and operating conditions must be adhered to. - 4
5 QUICK START GUIDE NOTE: Read and understand safety instructions before proceeding. READ CONNECT VERIFY - Read and comply with all safety instructions presented in this manual. In order to comply with the requirements of agency approvals (see data plate), specifications for conduit connections, wire gauge and type, fastener torque ratings, and operating conditions must be adhered to. - Connect AC power. Use conduit connections or cable glands. - Ground unit. - Connect command signal. - Connect feedback signal. - Voltage selector switch is set to the required voltage (230 VAC). - Command input signal is set to desired operation 4-20 ma. Factory set at 4-20 ma or (1-5V DC). - Feedback signal output is set to desired operation 4-20 ma or (1-5 VDC). Factory set at 4-20 ma. WARNING HAZARDOUS VOLTAGES ARE PRESENT ON THE CIRCUIT BOARD. TO PREVENT IGNITION OF HAZARDOUS ATMOSPHERES, COVER MUST BE TIGHT WHILE CIRCUITS ARE ENERGIZED. APPLY POWER OBSERVE CALIBRATE FINISH - Apply command signal. - Apply AC power. - Actuator should run to command position and stop. - Full range of command signal should result in desired range of actuator travel (factory setting is for full - Travel of 0% to 100%). - If actuator was installed on the pump at the factory, it has been factory calibrated. - If actuator is a retrofit or a non-standard range is desired, follow the calibration instructions in this manual. - Install cover. 5
6 SECTION 1 INTRODUCTION 1.1 GENERAL DESCRIPTION The PN-K packed plunger pumps are dosing pumps equipped with a packed plunger liquid end, oil bath lubricated gears in a sealed casing. Adjustment of stroke length can be carried out as the pump is operating or at stop. It is designed for non-stop industrial service. 1.2 PRINCIPLE OF OPERATION The Worm and worm wheel drive by means of the connecting rod transmits the rotary motion into the reciprocating motion of the plunger. The stroke of the plunger can be adjusted by the double eccentric mechanism. The Double eccentric mechanism consists of a stroke adjustment screw, inner eccentric and outer eccentric. The outer eccentric moves in the slot in the inner eccentric. The connecting rod is connected to outer eccentric. By adjusting the stroke adjustment screw, the relative position of the center of slot in the inner eccentric and the outer eccentric can be varied. When both the eccentric are in 90 degree, maximum stroke is achieved. When both are in 0 degree, Zero stroke is achieved. At the intermediate angles intermediate stroke is achieved. 6
7 1.3 TECHNICAL DETAILS: Maximum Discharge Pressure : Kg/cm2 Maximum Flow : Max Pressure. Stroke per Minute : SPM Reduction Ratio : Stroke Length : mm Motor Power : HP Plunger Diameter : mm Motor Speed : 1440 RPM Motor Input : 415V, 3 Phases, 50 HZ Weight : Kg (Approx.) Repeatability : +/- 3% Linearity : +/- 3% Steady State Accuracy : +/- 1% Flow Temperature : -5 to +10 % 7
8 SECTION 2 INSTALLATION 2.1 UNPACKING Pumps are shipped F.O.B factory and title passes to customer when carrier signs for receipt of pump. In the event that the damages occur during shipment, it is the responsibility of the customer to notify the carrier immediately and to file a damage claim. Carefully examine the shipping crate upon receipt from carrier to be sure there is no obvious damage to contents. Open the crate carefully so that the accessory items fastened to the inside of the crate will not be damaged or lost. Examine all material inside crate and check against packing specification to be sure that all items are accounted for and intact. 2.2 STORAGE & IDLE SERVICE Pumps that are not expected to put in service within 90 days of receipt should be stored in a dry place. Apply grease to all the non-painted surface of the pumps. Protect rubber parts from direct sun and from daily temperature variations. FAILURE TO PROPERLY STORE AND PROTECT THE EQUIPMENT MAY VOID ANY WARRANTY, EXPRESSED OR IMPLIED. OUTDOOR STORAGE IS NOT RECOMMENDED UNDER ANY CIRCUMSTANCES UNLESS SPECIFICALLY PREPARED FOR STORAGE PRIOR TO SHIPMENT FROM THE FACTORY. Maximum Estimated Storage Indoors, dry ambient controlled temperature: Initial months Extend preservation additional months Indoors, dry ambient uncontrolled temperature: Initial months Extend preservation additional months Outdoor storage: Not recommended. 2.3 MOUNTING Support the pump firmly in a level position on a solid, vibration free foundation preferably with the base above floor level to protect the pump from wash downs and to provide easier access for service. The Pump is provided with mounting holes to accommodate anchor bolts. A Roof should protect pumps installed outdoors. 8
9 2.4 ELECTRICAL INSTALLATION Verify the Motor data against your available main supply for the plant before carrying out connections. Connect the motor according to the indications given in the terminal box and the name plate of the motor. Before operating the pump, check the direction of rotation of motor which must be according to the arrow stamped on the motor adaptor base (Counter clockwise direction when seen from top). To reverse the direction of rotation just reverse either of the two phases of incoming power supply. DO NOT FORGET TO CONNECT THE PUMP TO EARTH Electric protection of the motor (Thermal protection or by means of fuse) is to correspond to the rated current indicated on the motor data plane. 2.5 PIPING Connect suitable sizing of suction and discharge piping. The piping material should be suitable for the chemical being pumped. Ensure that the thickness of pipe is suitable for withstanding the pressure requirements. Generally for high discharge pressures use seamless schedule 80 piping on the discharge line. Ensure that a strainer is fitted in the suction line and a suitable pressure relief valve is fitted in the discharge line. If required provide a pulsation dampner of suitable capacity. Capacity of the pulsation dampner is usually selected as 100 times the flow per stroke of the pump for fills and draw type. It is recommended to install a check valve at the point of dosing. 9
10 SECTION 3 START UP 1. Line up the pump with suitable suction piping and suitable accessories. 2. Open the isolation valves in suction and discharge piping. 3. Ensure that all the fasteners are fully tightened. 4. Fill the pump drive with 1 Lts of Hydrol 220 or equivalent oil. 5. Keep the stroke length at 15 to 20 %. 6. Run the motor and check the direction of rotation. It should be counter clockwise when viewed from Top. 7. At Zero discharge pressure ensure that the pump is delivering liquid. 8. Slowly increase the stroke length to 100%. 9. Allow the pump to run for some time. 10. Connect the discharge line with pressure relief valve. 11. Allow the pump to run for some time and ensure the pressure relief valve is relieving at the correct pressure. 12. Adjust the stroke knob to the required percentage and tighten the lock knob. 13. Observe for abnormal noise and vibration. 14. Check for any leak on the suction and discharge valves and tighten suitable. 15. Apply some grease or oil on the cross slide. This will help in reducing friction in the oil seal. Do not remove the cover on the cross slide without stopping the pump. 10
11 SECTION 4 LUBRICATION SCHEDULE The Pump drive should be filled with the specified oil till half of the sight glass (app. 1.0 Lts). The recommended hydraulic oils for the pump are shown below. MANUFACTURER TYPE BHARATH PETROLEUM HYDROL 220 INDIAN OIL CORPORATION SERVO SYSTEM 220 HINDUSTAN PETROLEUM ENCLO SECTION 5 MAINTENANCE The Pumps are designed to provide maintenance free operation for long periods. However, certain maintenance precautions are required for trouble free operation. 1. Ensure oil level in the pump drive unit at least once in 15 days. 2. Ensure that the cross slide is suitably lubricated at least once a week by applying small amounts of oil on the oil seal area to ensure friction free running. 3. Tighten the bolts of the cross slide guide and head periodically once in 15 days. 4. Change the entire drive oil after 500 Hrs of initial running and later every 2000 Hrs of operation. 5. Ensure that the check valves are not blocked or clogged once a month by flushing the liquid end. Clogging of the check valves will result in erratic discharge or no discharge. Complete blockage of the check valves will result in damage to the pump drive. 6. Lubricate the stroke adjustment mechanism once a month through the lock knob with grease or oil. 11
12 5.1 METHOD OF CHANGING GLAND PACKING 1. Loosen the packing gland nut. 2. Remove the entire head from the pump along with the plunger. 3. The Gland rope is to be cut to correct length and the edges have to be cut at 45 degree angle. Use the correct size of the Teflon rope ( For Length and size refer to point 16 in 6.2) 4. Insert the plunger into the head and pack the rope around the plunger using a blunt tool. 5. Remove the plunger. 6. Insert gland bush and gland nut into the head. Ensure that the gland bush is guided into the head. 7. Insert the cross slide lock nut and the cross slide nut into the plunger. 8. Apply grease on to the plunger and the gland packing. 9. Insert the plunger into the head. 10. Assemble the head along with the plunger on to the pump. 11. Hands tighten the cross slide nut. 12. Keep the stroke setting at 15 to 20% and run the pump at atmospheric pressure for 20 minutes. 13. Tighten the cross slide nut and cross slide lock nut. 14. Tighten the gland nut so as to tighten the gland packing slightly. Over tightening of the gland nut will lead to excessive heating of the liquid end even at 100% stroke. 15. Ensure that the plunger does not hit the liquid end even at 100% stroke. 16. Take care to assemble the head in the correct direction of the suction and discharge check valves. 12
13 13
14 6.1 BASIC PARTS: DRIVE END ITEM NO 1 PART NO DESCRIPTION QUANTITY B Motor (3 HP) Motor (2 HP) Motor (1.5 HP) Motor (1 HP) 1A S Motor Adaptor (3 HP) Assy 1Set Coupling Spring (3 HP) Coupling Spring (3 HP) New Coupling Spring (1 HP), GB Oil Level Indicator RECOMMENDED SPARES A Worm Shaft (1/8) for 80 Frame Motor (PNK XXD) B Worm Shaft (1/8) for 90 Frame Motor (PNK XXD) C Worm Shaft (1/8) for 100 Frame Motor (PNK XXD) A Worm Shaft (1/10) for 80 Frame Motor (PNK XXC) B C Worm Shaft (1/10) for 90 Frame Motor (PNK XXC) Worm Shaft (1/10) for 100 Frame Motor (PNK XXC) 1Set A Worm Shaft (1/15) for 80 Frame Motor (PNK XXB) B Worm Shaft (1/15) for 90 Frame Motor (PNK XXB) A Worm Shaft (1/25) for 80 Frame Motor (PNK XXA) B Worm Shaft (1/25) for 90 Frame Motor (PNK XXA) Spring Dowel 5 X 35 (HT) S Housing Assy 1 Set S Oil Drain with O-Ring 1 Set Oil Filling Cap with Gasket S Adjustment Shaft With Inner Eccentric 1 set Bearing Worm Gear 1/8 (PRIMEROYAL-K) P.B (for PNK XX D with 3 HP motor) 1 14
15 Worm Gear 1/10 (PRIMEROYAL-K) P.B (for PNK XX C with 2, 3 HP motors) Worm Gear 1/15 (PRIMEROYAL-K) P.B (for PNK XX B with 1.5HP motors) Worm Gear 1/25 (PRIMEROYAL-K) P.B (for PNK XX A with 1.5HP motors) Worm Gear 1/25 (PRIMEROYAL-K) CI (for PNK XX A with 1HP motors) Worm Gear 1/15 (PRIMEROYAL-K) CI (for PNK XX B with 1HP motors) Worm Gear 1/10 (PRIMEROYAL-K) CI (for PNK XX C with 1, 1.5 HP motors) Worm Gear 1/8 (PRIMEROYAL-K) CI (for PNK XX D with 1, 1.5, 2 HP motor) Guide Pin Connecting Rod Outer Eccentric Cover Stroke Adj. Screw S Stroke Adj. Knob With Grub Screw 1 Set S Lock Knob with O-ring 1 Set Cam Pin (PN-K) 1 21 M01305 Stud SS M10 X 85 (HT) Solid Dowel M10 X 20 (HT) Cross Slide Cross Slide Guide (8~40) Cross Slide Guide (50~70) Cross Slide Guide (71~90) Cross Slide Nut 1 25A Cross Slide Lock Nut Oil Seal Mounting Base Dowel Pin (PN-K) S PNK Drive End Fastener Kit 1 set S Seal Kit for PNK Drive End 1 Set Gear Bearing Stroke Label (PN-K) Lock Bolt Stopper GB,(PN-B,K,P) Bearing Cap (PN-K) 1 15
16 16
17 6.2 BASIC PARTS - LIQUID END (DIA MM) ITEM NO DESCRIPTIONS QUANTITY 16mm 20mm RECOMMENDED SPARES 1 Packing End Ring Nos 2 Packing Gland Rope Size 1 Set 5 mm 2 5mm 2 1 Set 3 Plunger Fixing Nut Plunger Gland Nut Gland Bush Head Suction & Discharge Valve Adaptor Gasket Nos 10 Ball Nos 11 Ball Guide Nos 12 L.E.Fixing Flange Suction & Discharge Valve 2 SETS S S 14 Ball Retainer Nos 15 Allen Bolt Size M8x20 (HT) Allen Bolt Size M12x30 (HT) 2 M01512 M
18 18
19 19
20 6.2 BASIC PARTS - LIQUID END (DIA MM) ITEM NO DESCRIPTIONS QUANTITY 25mm 32mm 40mm RECOMMENDED SPARES 1 Packing End Ring Nos 2 Packing Gland Rope Size 1 Set 5mm 2 8mm 2 8mm 2 1 set 3 Plunger Fixing Nut Plunger Gland Nut N N 6 Gland Bush N N 7 Head N N 8 Suction & Discharge Valve Adaptor Retainer Plate Gasket Nos 11 Suction Ball Seat Ball Seat Ball Ball Guide L.E.Fixing Flange Discharge Valve Assy 1 SET S S S 17 Suction Valve Assy 1 SET S S S 18 Allen Bolt Size M8x20 (HT) Allen Bolt Size M12x30 (HT) 2 M01512 M01512 M Hex Nut 1 - M01268 M HEX BOLT M10 X 65 4 M01682 M01682 M
21 21
22 6.2 BASIC PARTS - LIQUID END (DIA MM) ITEM NO DESCRIPTIONS QUANTITY 50mm 55mm 63mm 70mm RECOMMENDED SPARES 1 Packing End Ring Packing Gland Rope Size 1 Set 8mm 2 8mm 2 8mm 2 8mm 2 1 set 3 Plunger Adaptor Plunger Gland Nut N N N N 6 Gland Bush Head Suction & Discharge Valve Adaptor Retainer Plate Gasket , 12 Ball Seat Ball Ball Guide , SUCTION / DISCHARGE VALVE Hex Bolt M12X35 HT 2 sets S S S Hex Nut 1 M01268 M01268 M01268 M Hex Bolt M10X70 SS 4 M01685 M01685 M01685 M
23 6.2 BASIC PARTS - LIQUID END (DIA 90MM) ITEM NO DESCRIPTIONS QUANTITY 90mm RECOMMENDED SPARES 1 Packing End Ring Packing Gland Rope Size 1 Set 8mm 2 1 set 3 Plunger Adaptor Plunger Gland Nut N 6 Gland Bush N 7 Head N 8 Suction & Discharge Valve Adaptor Retainer Plate Gasket ,12 Ball Seat Ball Ball Guide SUCTION / DISCHARGE VALVE 2 SETS S 19 Hex Bolt M12X35 HT Hex Nut 1 M Hex Bolt M10X100 SS 4 M
24 SECTION 7 TROUBLE SHOOTING SYMPTOMS CAUSES REMEDIES Pump does not Operate Insufficient Delivery Erratic Delivery Gear Shaft Breakage Blown Fuse Motor Trip Low Liquid Level Worn or Dirty Check Valves Blocked Discharge Line Broken Wire Low Voltage Pump not primed Capacity Adjustment Set at Zero. Incorrect Capacity Adjustment Incorrect Pressure Relief valve Settings. Starved Suction Leaky Suction Piping Leaky Pressure Relief Valve Worn or Dirty Check Valves Leaky Suction Piping Leaky Pressure Relief Valve Incorrect Pressure Relief valve Settings. Worn or Dirty Check Valves Clogged or Dirty line Strainer Plunger or cross slide hitting against liquid end. Check for Short Circuit Check for Overload, Correct current setting in relay. Fill Liquid Clean and Replace Clear Line Locate and Repair Investigate and Correct Allow Suction Line and pump head to fill with liquid before pumping against pressure. Readjust. Readjust Capacity Correct the Pressure Relief Valve Settings Increase Pipe Sizing or Suction Head. Repair Piping Repair or Replace Pressure Relief Valve. Clean and Replace Repair Piping Repair or Replace Pressure Relief Valve. Correct the Pressure Relief Valve Settings Clean and Replace Clean Strainer Correct and change the gear shaft. Pump not developing Pressure Leaky Gland Packing Leaky Pressure Relief Valve Incorrect Pressure Relief valve Settings. 24 Tighten Gland Packing Add Rope Change Entire Packing Correct or replace pressure relief valve Correct the Pressure Relief Valve Settings
25 25
26 26
Instruction Manual PN-Z PACKED PLUNGER PUMP. This Manual should be made available to person responsible for installation, maintenance and operation.
MILTON ROY INDIA (P) LTD Metering Pumps Instruction Manual PN-Z PACKED PLUNGER PUMP This Manual should be made available to person responsible for installation, maintenance and operation. PUMP MODEL: SERIAL
More informationInstruction Manual. This Manual should be made available to persons responsible for Installation, Operation and Maintenance. Pump Model No...
MILTON ROY INDIA (P) LTD. Metering Pumps Instruction Manual M -Series This Manual should be made available to persons responsible for Installation, Operation and Maintenance. M- Pump Model No... Serial
More informationElectric Actuator Installation, Operation & Maintenance Manual
ICI Indelac Controls, Inc. Electric Actuator Installation, Operation & Maintenance Manual 6810 Powerline dr.-florence, Ky. 41042 - Telephone 859-727-7890, Tool free 800-662-9424 Fax. 859-727-4070, e-mail:
More informationSELF PRIMING CHEMICAL SERVICE PUMPS
SELF PRIMING CHEMICAL SERVICE PUMPS INSTALLATION AND OPERATING INSTRUCTIONS This Manual covers: SELF PRIMING MODEL RANGE J50ECX TO J250ECX STAINLESS STEEL*, and NON METALLIC SEAL PUMP MODEL: SERIAL NO:
More informationHALLMARK INDUSTRIES INC
Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge
More informationVal-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual
Manual No. 5AOP-OM1-2 Val-Matic Air / Oil Hydraulic Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION...
More informationOperations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD
Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD ----------------------------------------------------------------We Make Clean Air----------------------------------------------------------------
More informationCOMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL
COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL Model Number: Service: Serial Number: Installation Date: Installation Location / Application: PLEASE RECORD THE FOLLOWING DATA (Information is
More informationUSER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i)
USER MANUAL NEMA 48C Flange Mounted, Enclosed, Clutch Brake FMCBE Model 500 (i) In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual
More informationInstruction Manual. Series R Peristaltic Pump. For file reference, please record the following data:
Instruction Manual Series R Peristaltic Pump For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your
More informationEffective June 1, 2013 This guide supersedes all previous versions
Effective June 1, 2013 This guide supersedes all previous versions 3842 Redman Drive 1-800-797-7974 Fort Collins, CO 80524 www.commandlight.com L-CAS THANK YOU Please allow us to express a simple thank
More informationStandard Valves Series Globe Valves Series Angle Valves Series Way-Valves
Installation, Operation, Maintenance Instructions Standard Valves Series 035 000 Globe Valves Series 031 000 Angle Valves Series 033 000 3-Way-Valves 1 GENERAL INFORMATION These instructions are designed
More informationVEGETABLE OIL DISPOSAL UNIT (MSDU) OPERATOR & SERVICE MANUAL
VEGETABLE OIL DISPOSAL UNIT (MSDU) OPERATOR & SERVICE MANUAL MANUFACTURED BY P.O. BOX 51000 SHREVEPORT, LOUISIANA 71135-1000 PHONE 1-318-865-1711 1-800-24 FRYER This equipment chapter is to be inserted
More informationCRD610 Automatic Fitting Inserter
CRD610 Automatic Fitting Inserter OPERATIONS MANUAL VERSION 1.2 LAST EDITED 12.12.2018 cleanroomdevices.com 1 Table of Contents Title Page. 1 Table of Contents...2 1.0 General Product & Safety Information....3
More informationAPCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES
APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES Instruction D12043 June 2016 DeZURIK Instructions These instructions provide installation, operation and maintenance information for APCO CRF-100A Rubber
More informationF-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide
F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com
More informationM-3025CB-AV Fuel Pump
SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...
More informationSafe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual
Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual For Use with: SNS4, SNS6, SNS10 & SNS15 Models Additional supplements may be needed for
More informationBIOACTIVE SOLUTIONS AC DRAIN STATION
BIOACTIVE SOLUTIONS AC DRAIN STATION 98488-00 Overview The BioActive Solutions Drain Station is a chemical dispenser with a programmable timer designed primarily for dispensing chemicals into drains. Its
More informationElectronic Capacity Control
Milton Roy Electronic Capacity Control maxroy B, MacRoy, mroy, and Milroyal Product Family Pumps INSTALLATION, OPERATION, AND MAINTENANCE MANUAL This manual supersedes the following manuals: 339-0002-000,
More informationSOLAROY 12 VDC Metering Pump
SOLAROY 12 VDC Metering Pump INSTALLATION, OPERATION, AND MAINTENANCE MANUAL MODEL NUMBER: SR-1PS-TC250 and SR-1PS-TC375 Manual #23858 Revision 2/2012 Precautions / Warnings: Proper fuse installation (to
More informationInstallation, Operation, and Maintenance Manual
Industrial Process Installation, Operation, and Maintenance Manual Cam-Tite Ball Valve Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health and safety...2
More informationOperator s Manual. Nitro 1000 Nitro 1000X. Nitro 750 Nitro 750X. September REV0
Operator s Manual Nitro 750 Nitro 750X Nitro 1000 Nitro 1000X September.27.2018REV0 Table of Contents Introduction...3 Safety.....4 Equipment Requirements......5 What You Have Received. 5 Serial Number...6
More informationAPCO ASR-400/450 SEWAGE AIR RELEASE VALVES
APCO ASR-400/450 SEWAGE AIR RELEASE VALVES Instruction D12005 December 2012 Instructions These instructions provide installation, operation and maintenance information for the APCO ASR- 400/450 Sewage
More informationInstruction Manual. Series E7 Metering Pumps. For file reference, please record the following data:
Instruction Manual Series E7 Metering Pumps For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your
More informationDeZURIK 2 20" BOS BUTTERFLY VALVES
2 20" BOS BUTTERFLY VALVES Instruction D10459 October 2013 2-20 BOS Butterfly Valves Instructions These instructions provide information about BOS Butterfly Valves. They are for use by personnel who are
More informationfor NEPTUNE SERIES 600 dia-pump MODELS 610 thru 647
for NEPTUNE SERIES 600 dia-pump MODELS 610 thru 647 NEPTUNE CHEMICAL PUMP CO., INC. Lansdale, PA. 19446 * Tel.: 215-699-8700 * FAX: 215-699-0370 WARNING LOCKOUTS ARE REQUIRED BEFORE SERVICING THIS EQUIPMENT.
More information24 Linear Actuator 115 Volts A.C. (Cat. # C430A)
Installation, Operation & Parts Manual Read carefully the information provided. Retain manual for future reference. 24 Linear Actuator 115 Volts A.C. (Cat. # C430A) Page 1 of 8 IS10007.doc 11/15/06 IMPORTANT!
More informationBCFS Belt Driven Centrifugal Filtered Supply Fans
BCFS Belt Driven Centrifugal Filtered Supply Fans INSTALLATION, OPERATION & MAINTENANCE MANUAL IM-4300 August 2014 Throughout this manual, there are a number of HAZARD S that must be read and adhered to
More informationElectronic Capacity Control
Electronic Capacity Control maxroy B, MacRoy, mroy, and Milroyal Product Family Pumps INSTALLATION, OPERATION, AND MAINTENANCE MANUAL This manual supersedes the following manuals: 339-0002-000, 339-0006-000,
More informationTECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:
ACORN SAFETY P.O. BOX 3527 CITY OF INDUSTRY, CA 91744-0527 UNITED STATES OF AMERICA WWW.ACORNSAFETY.COM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS DECK MOUNTED EYE/FACEWASH Model S0730 / S0740
More informationLinear Actuator. Installation Manual. warranty installation parts list. Linear Actuator Installation Manual Page 1
Linear Actuator Installation Manual warranty installation parts list January 2004 Linear Actuator Installation Manual Page 1 MA1221B12 Warranty Information Chore-Time Equipment ( Chore-Time ) warrants
More informationACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump
ACHL Series Pump Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump Catalog: 02-9245ME February 2013 Model # Serial # Drawing # Order # Mfg. Date Table of Contents page
More informationPENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Before installation, these instructions must be read carefully and understood. PRODUCT WARRANTY Emerson warrants its Penberthy products as designed and manufactured to be free of defects in the material
More informationFull View Flow Indicator
Full View Flow Indicator Threaded and Flanged Process Connection Installation / Operation / Maintenance Manual P.O. Box 1116 Twinsburg, OH 44087 Phone: 330/405-3040 Fax: 330/405-3070 E-mail: view@ljstar.com
More informationLifeGuardLift. LifeGuard Power Lift Model #100287A OWNERS MANUAL. Rev: 2/14/11
LifeGuardLift OWNERS MANUAL LifeGuard Power Lift Model #100287A Rev: 2/14/11 Table of Contents 1. ASSEMBLY INSTRUCTIONS A. Lift Assembly B. Setup C. Disassembly 2. CONTROL SYSTEM A. Batteries B. Battery
More informationRaydot LLC 24 Actuator (115 VOLT)
Installation, Operation & Parts Manual Read carefully the information provided. Retain manual for future reference. Raydot LLC 24 Actuator (115 VOLT) 145 Jackson Ave. S. Cokato, MN 55321-USA (320) 286-2103
More informationGRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions
GRUNDFOS INSTRUCTIONS MTC Installation and operating instructions LIMITED WARRANTY Products manufactured by GRUNDFOS PUMPS CORPORATION (Grundfos) are warranted to the original user only to be free of defects
More informationGARDEN HOSE UTILITY PUMP
GARDEN HOSE UTILITY PUMP MODEL #HPP360, HPP12V, 473707 MODEL #HPP360, 473707 MODEL #HPP12V ATTACH YOUR RECEIPT HERE Purchase Date SAFETY INFORMATION Please read and understand this entire manual before
More informationHA/HAB Fiberglass Wall Mount Ventilators
HA/HAB Fiberglass Wall Mount Ventilators INSTALLATION, OPERATION & MAINTENANCE MANUAL IM-3100 August 2015 Throughout this manual, there are a number of HAZARD S that must be read and adhered to in order
More informationCRD600 Automatic Fitting Inserter
CRD600 Automatic Fitting Inserter OPERATIONS MANUAL VERSION 2.3 LAST EDITED 12.07.2018 cleanroomdevices.com 1 Table of Contents Title Page.. 1 Table of Contents. 2 1.0 General Product & Safety Information...3
More informationCLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"
CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER" CRD600 Automatic Fitting Inserter OPERATIONS MANUAL VERSION 2.1 LAST EDITED 7.25.14 DOCUMENT NUMBER 001 cleanroomdevices.com 1 Table of
More informationInstallation Guide Document N Cleanroom Mirrors Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016
Document N0. 1800-09 Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000
More information1250 LB. CAPACITY MECHANICAL WHEEL DOLLY
1250 LB. CAPACITY MECHANICAL WHEEL DOLLY 67287 SET-UP AND OPERATING INSTRUCTIONS Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result
More informationTITAN FLOW CONTROL, INC.
PREFACE: TITAN FLOW This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI)Full Body Swing Check Valves. To ensure efficient and safe
More information24-48 HP250II Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date: Document #: 2448HP250OOOM Revision Date: 1/10/11
24-48 HP250II Butterfly Valve Operation and Maintenance Manual Job Name: Contractor: Date: Document #: 2448HP250OOOM Revision Date: 1/10/11 SAFETY MESSAGES All safety messages in the instructions are flagged
More informationOperation and Maintenance Manual for Multipurpose Actuators. 120 VAC Actuator 12 VDC Actuator 12 VDC Actuator
Joyce/Dayton Corp. Operation and Maintenance Manual for Multipurpose Actuators 120 VAC Actuator 12 VDC Actuator 12 VDC Actuator The recommendations in this manual for installation, operation and maintenance
More informationMV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US
MV Series Motors Operation & Parts Manual Models M3V, M5V, M5V-US Introduction This manual pertains to drum pump motors MV Series. Finish Thompson, Inc. thanks you for choosing our products. We believe
More informationOwner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save Save This This Manual Keep Keep this this manual manual for for the the safety safety warnings warnings and and precautions, assembly, assembly, operating, inspection,
More informationMarlow Series Cast Iron Swimming Pool Pumps
INSTRUCTION MANUAL SECTION 360A AC1683 REVISION C INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER'S USE. Marlow Series Cast Iron Swimming Pool Pumps 3B28EC 3B32EC PLEASE FILL IN DATA FROM YOUR PUMP NAMEPLATE
More informationMV Series Motors Operation & Parts Manual
MV Series Motors Operation & Parts Manual Models M3V, M5V, M5V-US For use with M3V s/n 101057 & below, M3V-UK s/n 103013 & below, M5V & M5V-US s/n 102972 & below. EU Declaration of Conformity Finish Thompson
More informationOPERATIONS MANUAL MODEL MT-500
OPERATIONS MANUAL MODEL MT-500 Machine Serial Number: Specification Number: Engine Serial Number: SOLD & SERVICED BY SAFETY PRECAUTIONS AS STATED IN OSHA, THE EMPLOYER SHALL PERMIT ONLY THOSE EMPLOYEES
More informationFitting Instructions Kit Nos. 9100, 9110, 9120 MECHANICAL POWER TAKE-OFF
Fitting Instructions Kit Nos. 9100, 9110, 9120 MECHANICAL POWER TAKE-OFF Fitting / Operating Instructions Kit Nos. 9100, 9110, 9120 These instructions cover kits from 9/07/1997 i 01 INTRODUCTION 02 GENERAL
More informationOperating Instructions and Parts Manual Long Chassis Service Jacks
Operating Instructions and Parts Manual Long Chassis Service Jacks Models JSJ-3T/JSJ-5T/JSJ-10T WMH TOOL GROUP 2420 Vantage Drive Elgin, Illinois 60123 Part No. M-454430 Ph.: 800-274-6848 Revision A 8/05
More informationAGCO. Corn Header Manual d HEADSIGHT.COM
AGCO Corn Header Manual 09020401d HEADSIGHT.COM 574.546.5022 About Headsight Headsight Contact Info Headsight, Inc. 4845 3B Road Bremen, IN 46506 Phone: 574-546-5022 Fax: 574-546-5760 Email: info@headsight.com
More informationAutomated I.V. Stand Cat. No OPERATOR S MANUAL. Operation& Maintenance Instructions. Raising the Standard of Care!
Automated I.V. Stand Cat. No. 741314 OPERATOR S MANUAL Operation& Maintenance Instructions Raising the Standard of Care! Table of Contents Warranty....................... 2 Hardware.......................
More informationMetroPrime 22MPC Self-Priming Centrifugal Pump
Page 1 of 6 prevent priming or reduce pump capacity. OPERATION The 22 MPC-Metropolitan Pump is a self-priming centrifugal pump and only requires priming prior to its initial start. The pump will retain
More information60 Series End-Mount Brake Instructions Standard Housing
Bulletin No. BK4655 (04/18) 60 Series End-Mount Brake Instructions Standard Housing Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and
More informationCLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"
CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER" CRD600AF Automatic Fitting Inserter With Auto Feed OPERATIONS MANUAL (Shown with optional alcohol dispenser) 1 VERSION 1.1 LAST EDITED
More informationTITAN FLOW CONTROL, INC.
PREFACE: This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) Wafer Style, Dual Plate Check Valves. To ensure efficient and safe operation
More informationJunior Sandblaster. Model #51 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL & WEAR EYE PROTECTION
Junior Sandblaster Model #51 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL & WEAR EYE PROTECTION PARTS LIST AND PART NUMBERS 01.Red Rubber Air Hose (5Ft) P51-01 02. Male Insert
More informationMODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION
SERIES 000/S-X MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION Publication S000X- VER045- For information on this product and other
More informationP-200 Plastic Utility Pump for Petroleum Products
P-200 Plastic Utility Pump for Petroleum Products Owner s Manual 5252 East 36th Street North Wichita, KS USA 67220-3205 TEL: 316-686-7361 FAX: 316-686-6746 A Great Plains Ventures Subsidiary www.gpi.net
More informationAVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"
AMERICAN AVK COMPANY AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12" TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION
More informationUnilift KP 150, KP 250, KP 350
GRUNDFOS INSTRUCTIONS Unilift KP 150, KP 250, KP 350 Installation and operating instructions DRAINAGE PUMP 1Z28 LIMITED WARRANTY Products manufactured by GRUNDFOS PUMPS CORPORATION (Grundfos) are warranted
More informationHydraulic Clutch Jack
Hydraulic Clutch Jack Operating Instructions & Parts Manual Model Number Atd-7404 Capacity 500 Lb. Atd Tools Inc. 160 Enterprise Drive, Wentzville MO 63385 Printed in China ATD7404-M0 05/07 Save these
More information2" - 24" OS Series Butterfly Valves. Operation and Maintenance Manual. Job Name: Contractor: Date:
s Operation and Maintenance Manual Job Name: Contractor: Date: Document #: IOM Revision Date: 10/2/2016 SAFETY MESSAGES All safety messages in the instructions are flagged with an exclamation symbol and
More informationFTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE
FTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE TABLE OF CONTENTS SECTION 1 General Information: Model Description Pg 2 Serial Numbers Description of Operation SECTION 2 Safety Instructions: Pg
More informationNor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves
Instructions Safety Messages These instructions are intended for personnel who are responsible for installation, operation and maintenance of your DeZURIK Actuator. All safety messages in the instructions
More informationOPERATING INSTRUCTIONS PLEASE READ CAREFULLY
OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 925-0330 Rev 0 0416 TABLE OF CONTENTS SAFETY SUMMARY... 3 SPECIFICATIONS... 4 1.0 INTRODUCTION/DESCRIPTION.... 5 2.0 LOCATION AND MOUNTING... 5 3.0 CONNECTIONS
More informationQUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE
QUICK START GUIDE OWNER S MANUAL SAFETY, INSTALLATION, OPERATION & PARTS AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL 877-278-2797 DO NOT RETURN TO STORE! WARNING This equipment must be installed
More informationSUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL
SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM Performance Model HP GPH of Water @ Total Feet Of Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. 25 ft. Max. Lift SUNC1200
More informationShortening Disposal Unit
Shortening Disposal Unit (SDU 50, 90, 100 and BKSDU) Installation, Operation, Service and Parts Manual Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified
More informationOperation and Maintenance Manual for. Joyce/Dayton Linear Actuator Pound Capacity AC Actuator (with limit switch and potentiometer)
Joyce/Dayton Corp. Operation and Maintenance Manual for Joyce/Dayton Linear Actuator 1500 Pound Capacity AC Actuator (with limit switch and potentiometer) WARNING! The recommendations in this manual for
More informationROLLER GRILL Instruction Manual Model #8223, 8224, Part No Revised:March 2008
ROLLER GRILL Instruction Manual Model #8223, 8224, 8225 Part No. 88189 Revised:March 2008 Safety Precautions Models #8223, 2 #8224, #8225 FORWARD This manual covers the model # 8223, # 8223, 8225 ROLLER
More informationBray/ VAAS Slurry Series Knife Gate Valve 760/762/765/766/767/768 Series Operation and Maintenance Manual
Bray/ VAAS Knife Gate Valve 760/762/765/766/767/768 Series Table of Contents Definition of Terms 1 Safety Instructions 1 Introduction 2 Unpacking 2 Storage 2 Installation 3 Commissioning 3 Cylinder-Operated
More informationRead this entire manual before operation begins.
Read this entire manual before operation begins. Record below the following information which is located on the serial number data plate. Serial No. Model No. Date of Installation Contents Specifications.............
More informationInstallation and Maintenance Manual
Installation and Maintenance Manual WorldWide Helical Inline Speed Reducers This operation manual includes important information for the installation, assembly, operation and maintenance of the WorldWide
More informationH.S. MACHINERY RING COMPRESSORS
OPERATION & PARTS MANUAL Thank you for purchasing an H.S Machinery Limited Regenerative Blower. This product is manufactured under strict ISO-9001-2000 quality control guidelines to ensure your satisfaction.
More informationAir Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL
Air Operated Double Diaphragm Pump M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL 0.5 I.O.M rev 05. 12/2015 INDEX Title Section Introduction.1 Safety.2 Warranty, General
More informationHeavy Duty Engine Cranes
Heavy Duty Engine Cranes Operating Instructions & Parts Manual Model Number Atd-7484 Atd-7485 (Foldable Legs) Capacity 2 Ton 2 Ton Model Atd-7484 Model Atd-7485 Atd Tools Inc. 160 Enterprise Drive, Wentzville,
More informationJET METER INSTRUCTIONS
UNPACKING Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you undamaged. If you do find an item that is broken
More informationInstallation, Operation, & Maintenance Instruction. Bulletin #: IOM-PN-LCM D
Installation, Operation, & Maintenance Instruction Bulletin #: IOM-PN-LCM-0403- D Manufacturers of Quality Pumps, Controls and Systems ENGINEERED PUMP OPERATIONS 2883 Brighton Henrietta Townline Road Rochester,
More informationWELDING POSITIONER S OPERATION MANUAL CWP40
WELDING POSITIONER S OPERATION MANUAL CWP40 Revision May 19 2015 Note: The information contained in this manual is intended to be accurate. However the manufacturer retain the rights to make changes in
More informationStraight-Bore Clutch LSCC-32, 44, 54
Straight-Bore Clutch LSCC-32, 44, 54 1 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject to change without notice. Technical
More information3-20 2FII & Groundhog Bonded Seat Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date:
3-20 2FII & Groundhog Bonded Seat Butterfly Valve Operation and Maintenance Manual Job Name: Contractor: Date: Document #:3202FIIGD Revision Date: 1/10/11 SAFETY MESSAGES All safety messages in the instructions
More informationDEMA SQUIRT DRAIN UNIT
DEMA SQUIRT DRAIN UNIT Overview The Squirt is a chemical dispenser with a programmable timer designed primarily for dispensing chemicals into drains. Its most clear intended use is for drain applications
More informationTECHNICAL SERVICE MANUAL
Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com TECHNICAL SERVICE MANUAL VIKING HELICAL GEAR REDUCERS A, B, AND C SIZES SECTION PAGE ISSUE
More informationOperating Instructions & Parts Manual. Truck Drain. Model 48UJ80 and 48UJ81
Operating Instructions & Parts Manual EN Truck Drain Model 48UJ80 and 48UJ81 PLEASE READ AND SAVE THESE INSTRUCTIONS. READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT
More informationWARNING. Electric Recovery Winch. General Safety Precautions
1 Electric Recovery Winch Thanks for purchasing a WINCH. This manual covers operation and maintenance of the winch. All information in this publication is based on the latest production information available
More informationSplit Body Valves with Bellows Seal Series Globe Valves Series Angle Valves Series Way-Valves
Installation, Operation, Maintenance Instructions Split Body Valves with Bellows Seal Series 025 300 Globe Valves Series 027 300 Angle Valves Series 028 300 3-Way-Valves 1 GENERAL INFORMATION These instructions
More informationModel C230 Pump Controller
MANUAL Model C230 Earthsafe Systems, Inc. 7553 S. Madison Willowbrook, IL 60527 T: (630) 794-5100 F: (630) 794-5106 info@earthsafe.com www.earthsafe.com March 1, 2010 The information contained herein is
More informationPARTS AND INSTALLATION MANUAL
PSP-3240 POLYPROPYLENE SELF-PRIMING 2 CENTRIFUGAL PUMP PARTS AND INSTALLATION MANUAL PSP-3240 Shown with GX-160 Honda CDS-JOHN BLUE COMPANY DIVISION OF ADVANCED SYSTEMS TECHNOLOGY, INC. 165 Electronics
More informationThe following precautions should be taken when working with metering pumps. Please read this section carefully prior to installation.
MILROYAL D DISC DIAPHRAGM Low Flow Liquid End Manual No : 54248 Rev. : 00 Rev. Date : 11/2015 PRECAUTIONS The following precautions should be taken when working with metering pumps. Please read this section
More informationMODEL HD-BTC. Installation, Operation & Repair Parts Information REV041416
MODEL HD-BTC Installation, Operation & Repair Parts Information REV041416 TABLE OF CONTENTS SAFETY INSTRUCTIONS 1 DEFINITIONS 1 SPECIFICATIONS 2 INSTALLATION INSTRUCTIONS 2 OPERATING INSTRUCTIONS 2 MAINTENANCE
More informationRead this entire manual before operation begins.
Read this entire manual before operation begins. Record below the following information which is located on the serial number data plate. Serial No. Model No. Date of Installation Contents Specifications.............
More informationBoston Gear Ratiotrol DC Motor Speed Control
Boston Gear Ratiotrol DC Motor Speed Control P-3017-BG Doc. No. 60007 Installation and Operation DCX plus Series II Enclosed Models 1/12-1 HP a division of Altra Industrial Motion Contents l General Information
More informationFIXED DEPTH INSERTION METER INSTRUCTIONS
UNPACKING Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you undamaged. If you do find an item that is broken
More informationp.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.
p.t.o. Slip clutch 65517 Installation Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com Read
More informationCONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1
TECHNICAL SERVICE MANUAL industrial heavy duty motor speed pumps SERIES 4076 AND 4176 SIZES hle, ate and ale SECTION TSM 710.1 PAGE 1 of 8 ISSUE B CONTENTS Introduction....................... 1 Safety
More information