Troubleshooting and Maintenance of Air-Powered Pumping Systems

Size: px
Start display at page:

Download "Troubleshooting and Maintenance of Air-Powered Pumping Systems"

Transcription

1 Troubleshooting and Maintenance of Air-Powered Pumping Systems David Kaminski QED Environmental Systems Inc. Ann Arbor, MI / San Leandro, CA Copyright QED Environmental Systems, Inc ; all rights reserved. The information contained within this document may not be published, broadcast, rewritten or otherwise distributed without prior written authorization from QED. Today s Webinar Topics Air-powered pump system components Principles of operation how it works Diagnosing the problem: Look and Listen Common operational issues Safety considerations during pump maintenance Tips on pump removal and installation Pump disassembly tools and tips Cleaning frequency and service life expectations Spare parts and spare pumps save time and $$$ Accessories for improving pump performance 1

2 2 QED AutoPump AP4+ Pump Components Discharge Head & Air Valve Assemblies Discharge Tube/Float Guide Pump Body (Casing) Float Assembly with Guide Plates Actuator Rod Inlet Valve Assembly and Inlet Screen Air-powered automatic pump: How it works Discharge Cycle When float reaches the top of its travel, exhaust valve closes and air inlet valve opens Air pressure against liquid closes inlet check valve and pushes liquid up discharge tube As liquid level drops, float follows and pulls actuator rod down, closing the air inlet valve and opening exhaust valve to repeat Fill Cycle Fill Cycle Hydrostatic pressure opens inlet check valve As pump fills with liquid, air escapes through exhaust valve and internal float rises

3 Normal pump operating characteristics 1. Cycling you should hear a release of air pressure when the pump is cycling (exhaust cycle). 2. Pressure gauge if there is a filter/regulator at the well head, you can see a slight drop in the air pressure (5-10 PSI) with each pump discharge cycle 3. Cycle counter the cycle counter should advance a half count in the discharge cycle, then advance a full count with an audible click during the exhaust cycle What if my pump isn t cycling? Determine if the issue is an operating condition in the well or a pump malfunction Examples of operating conditions: Very low well yield (will eventually cycle check counter) Liquid level has dropped below actuation point Air supply pressure insufficient for discharge Excessive discharge line back pressure Examples of pump malfunction Float sticking due to solids buildup, slime, silt Check valve not working due to debris, sand Air valve mechanism plugged or out of adjustment 3

4 First Step: Look and Listen Look at the well head and connections for an obvious problem broken fittings or loose connections, tubing kinks, etc. Listen for an air leak from a fitting or line at the well cap/flange Look at the air pressure gauge for low or no pressure Listen for a continuous discharge condition you ll hear a hissing sound coming from the pump exhaust line (may be above or below well cap) and/or the liquid discharge line Pump stuck in discharge mode Continuous air from the exhaust line (and sometimes the discharge line) can indicate that the pump is stuck in discharge mode The float may be stuck due to buildup on the discharge tube or debris inside the pump Cleaning will usually resolve the problem, but may require air valve adjustment 4

5 Pump stuck between cycles If the pump is stuck between cycles, both the air inlet and exhaust valves will be open, allowing air to pass continuously out of the exhaust port (and possibly through the discharge line) called a crossover malfunction Additional evidence: the cycle counter may be stuck between cycle counts Possible causes include an air valve mechanism that is worn (e.g., pivot pin, lever half bushing) or is out of adjustment Cleaning, adjustment or repair may be required to resolve the problem Is liquid level above actuation point? To determine if you have sufficient liquid over the pump to actuate the air valve, you need to know: The installed depth of the pump The pump model and its actuation point The liquid level in the well/riser If the liquid level is above the actuation point and there is sufficient air pressure but the pump isn t cycling, there may be a problem with the pump, such as a stuck float, debris, actuator rod hang-up, air valve issue, etc. 5

6 6 Pump Actuation Point The point at which the liquid level inside the pump activates the air valve mechanism is called the actuation point The actuation point is the distance from the bottom of the pump to the top of the float travel (top of inlet on top-fill pumps) This distance varies based on pump body length, float length and inlet position and is specified for each pump model The pump position in the well determines the maximum drawdown level in the well How vacuum affects the pump actuation point A vacuum applied to the well (e.g., landfill gas collection, vapor extraction) will RAISE the actuation point above the design point when the pump exhaust is outside the well The increase in the actuation point is based on the amount of vacuum applied to the well, measured in inches (centimeters) of water column (WC) In the example, a vacuum of 20 (51 cm) WC raises the actuation point of the pump from 33 (84 cm) to 53 (135 cm)

7 How to check if vacuum is preventing the pump from cycling 1. Install a level tape in the well/riser or use a dedicated level measurement system (e.g., bubbler line) 2. Turn off and release vacuum at the well cap/flange 3. Monitor the liquid level and wait for it to begin dropping 4. If the pump starts cycling at the design actuation point, the problem is insufficient submergence under vacuum. Possible solutions: Lower the pump in the well/riser if possible Use a shorter pump model with a lower actuation point If air exhaust is outside the well, change to inside well or install an equalization valve to reference exhaust to vacuum Exhaust air equalization valve Installed in the exhaust line below the well cap/flange with exhaust terminated outside the well Nearly all of the exhaust air is vented through the valve outside the well, with only a small amount of air entering the well when the vacuum reference port opens When exhaust line pressure is equal to atmospheric pressure outside the well, the spring loaded valve closes and allows vacuum to be applied to the exhaust line, allowing the liquid level to be pumped down as low as possible 7

8 8 Pump not cycling - insufficient air pressure at the well head A pump may not cycle if the air pressure is too low to lift the liquid to the surface or to overcome any header loss or force main back pressure Air-powered pumps need a minimum of 0.5 PSI air pressure for every foot of lift desired plus 1.0 PSI for every PSI of back pressure in the header line Test for low air pressure: increase pressure at well head in 5 PSI increments; pump will start cycling if pressure was too low to overcome lift requirement Test for high header line back pressure: turn off air, disconnect discharge line at header and direct it back into well; pump will start cycling if pressure was too low to overcome header back pressure How to jump start your pump Sometimes a quick jump start can get the pump cycling again when it stalls or sticks (i.e., float hung up) Method 1: remove the air line from the filter/regulator, allow all the air to exhaust from the pump, then reconnect the air line; pump should cycle if sufficiently submerged Method 2: unbolt the well cap/flange and shake the pump system up & down to dislodge the float If the jump start method gets the pump cycling again, it s a good indication that the pump needs to be cleaned, serviced or adjusted to maintain consistent operation and maximum performance

9 Air Valve Mechanism Adjustment The air valve mechanism should not require adjustment unless it has been repaired or has some wear from long-term use If adjustment is necessary, contact QED for information and instructions based on pump model Air Valve Out of Adjustment (Gap between valve mechanism and pump head) After Proper Air Valve Adjustment Pump maintenance safety considerations Wear appropriate safety gear Safety glasses with side shields or a full face shield (best for liquids) Protective outer clothing (e.g. Tyvek jump suit) Chemically resistant gloves taped at top to prevent leaks Other safety gear required for the site (hi-vis clothing, hard hat, steel toe boots, etc.) Most importantly make sure the pump and all air and discharge lines are not pressurized before you begin any disassembly! 9

10 10 Shut-offs, check valves and blow-outs Shut off manual valves at the air supply and discharge header to isolate the pump Release any air pressure from the pump If the pump discharge tubing is filled with liquid, you can lighten your load by using the QED Pump Blow-Out Kit (Part Number 40234) to empty the line before lifting the pump Lifting the pump and tubing Wear protective gloves and get a good grip on the tubing or hoses Try to avoid getting kinks in tubing kinks tend to be permanent and can restrict flow or create leaks Use your legs, NOT YOUR BACK! Use a step ladder or tailgate to gain some height and leverage If the system is too heavy to lift, use a winch, crane or automated pump puller

11 11 Pump Pull-E - faster & safer pump pulls Designed to guide pump tubing out of the well without kinking and to reduce lifting effort to avoid worker injuries Deep-vee roller bolts onto flange or straps to outside of 6 and 8 gas well casings

12 Keeping debris out of air lines Debris in air lines (dirt, insects, etc.) can clog filter regulators and plug pump air valve poppets Cap or tape end of tubing after pulling the pump to avoid debris Blow out air header lines before connecting pump air supply hoses 12

13 13 Cleaning air-powered pumps Determining cleaning frequency Cleaning frequency is determined on a site-by-site basis - some sites may go a year or more without cleaning while others may require cleaning as often as monthly or more where high solids or sticky deposits occur If no site history, pull new pumps after 1-3 months of use to gauge need for cleaning or wait for indication of stalling Planned maintenance can be more cost effective than responding to pumps that shut down when dirty

14 14 AutoPump *AP4+ Designed for easier cleaning Easier disassembly: removing four bolts on bottom inlet allows complete pump disassembly in minutes no turning of the inlet assembly or O-ring hang-up/dragging Easier service: quick-release clip on actuator rod allows quick float removal for easier cleaning. Pump body has a high-polish ID finish to reduce solids build-up and precision bore sizing to improve O-ring fit Increased durability: All metal parts are 304SS or higher for improved corrosion resistance; plastic parts are high-strength & hightemperature engineering plastics (PVDF, PEEK) Increased warranty: 5-year full warranty with no pro-rating in later years * Patent Pending AutoPump AP4+ Design Features New Air Valve Mechanism Design The new captured pin design eliminates need for fasteners, clips or cotter pins at valve stem Improved reliability, easier to service exhaust seat is easier to adjust Now on all AP4 models!

15 15 Introducing the first low-maintenance air-powered pump: The Ultra lasts up to 10 times longer between cleanings and takes up to 50% less time to clean The Ultra combines all of the design features and rugged reliability of the AutoPump AP4+ in an innovative design that reduces build-up of solids and sticky deposits on the float and center rod Greater reliability in challenging applications Fewer pump pulls for maintenance Cleaning is faster and easier Design Features Non-stick float and electro-polished center rod reduce solids buildup, low-friction engineered plastic guide plates reduce pump stalling All metallic parts are 316-grade SS for greater corrosion resistance and reliability Non-stick, high polish finishes make cleaning easier can be as easy as wipe and rinse

16 16 Field testers compared the new AutoPump Ultra to existing pumps and reported the following results: Maximum uptime Minimum Downtime Teardown and cleaning took absolutely no effort No soaking required Only needed a water spray to clean Removed residue with some clean water and the swipe of a hand Easier to clean by 50% It s been running for four months and I haven t had to clean it yet! Ultra pump test pulled in October 2015 after one year

17 17 Annual Pump Cleaning Savings with AutoPump Ultra Standard Pump AutoPump Ultra Cleaning Frequency Pump Pulls/Year AP Ultra Frequency Pump Pulls/Year Annual Pulls Saved $100/pull $150/pull $200/pull 4 weeks weeks 3 10 $ 1,000 $ 1,500 $ 2,000 2 weeks 26 8 weeks 7 19 $ 1,900 $ 2,850 $ 3,800 2 weeks weeks 3 23 $ 2,300 $ 3,450 $4,600 1 week weeks 3 49 $ 4,900 $ 7,350 $ 9,800 Using the AutoPump AP4 Ultra and reducing your cleaning frequency from monthly to quarterly at $100 per cleaning event saves $800 annually and frees up as much as 16 hours of technician field time AP4 Ultra Calculator Tool QED s latest calculator tool helps you find your potential pump maintenance time and cost savings using the AP4 Ultra pump Set up for both in-house maintenance and contractor doing field O&M work The calculator will display the time savings or cost savings against alternative air-powered pumps Find it at qedenv.com/ultracalc

18 18 AutoPump AP4.5 Ultra Greater Clearance = Lower Maintenance Incorporates all of the lower-maintenance features of the AutoPump Ultra into a wide-body design with increased internal clearances better handling of solids, precipitates and sticky deposits Larger discharge volume per cycle = less wear, longer service life Greater clearances further reduce cleaning frequency by 3x 5x or more Standard AP Ultra AP4.5 Ultra AutoPump AP4.5 Ultra Greater Clearance = Lower Maintenance Design features Increased clearance between float and discharge tube from to (3x greater) Increased area between float and casing to gallons (1.9L) per cycle Overall dimensions: 4.6 OD x 39.9 long (11.6 cm x 101 cm) Applications Primary application in LFG well dewatering and vertical landfill leachate risers Minimum well diameter is 6 (150mm) ID AutoPump Ultra AutoPump AP4.5 Ultra

19 Getting the right tools QED offers a complete tool kit for AP4 pumps Double pin spanner to remove threaded inlet Honing tool to remove hard deposits from pump body Casing removal tool, punch and Allen wrench Optional pipe vise with rubber jaws to hold pump body What about tools for the AP4 Plus? The newly redesigned AP4+ has a bottom inlet design that comes off easily by removing three small bolts no need for the spanner or casing tool! The honing tool and pipe vise (if desired) can be purchased separately AP4 Service Tool Kit 19

20 20 Cleaning agents and supplies Degreasing agents such as Simple Green or Detergent 8 can remove oily or slimy deposits Scouring pads can remove about 90% of bio-growth and buildup on pump parts (but avoid float damage!) Use brush kits with extended handle to clean inside the pump body and discharge tube Cleaning agents for scale buildup Cleaning solutions such as CLR or common acids such as citric acid and vinegar (acetic acid) can help remove heavy mineral deposits and biorock avoid hydrochloric or sulfuric acids Do not leave metal parts in strong acids overnight! Don t clean acetal (Delrin ) plastic parts with acids it can weaken/damage them NEVER mix acids with other cleaning solutions ALWAYS rinse other cleaners away first to avoid dangerous (and potentially fatal) chemical fumes

21 Spare parts for field repairs Spare parts needed will vary by pump model, but most require only a handful of parts The quantity of spare parts you will need is dependent on the size of your site and how many pumps you have QED Customer Service can help you with recommended parts for your pumps, such as check balls, O-rings, fittings and springs Spare pumps = major cost savings When labor for cleaning or repairs exceeds minutes, having one or more spare pumps can save considerable cost over immediate field repair Less downtime, especially valuable in LFG wells Maintenance can be done in the shop or by the manufacturer rather than under field conditions No need to stock every necessary spare parts Shipping for parts or pump repairs can be done at economy rates rather than overnight shipping 21

22 22 Accessories to improve performance and reduce maintenance in tough applications Silt and Foam Filter Designed to reduce solids loading in pumps to improve performance and extend maintenance intervals Threads into pump inlet assembly (replaces standard inlet screen, requires a modified inlet assembly) Filter pad material can be cleaned or replaced Can also improve pump performance and reduce leachate emitting from external exhaust line in wells with foaming leachate Accessories to improve performance and reduce maintenance in tough applications Wide Slotted Float Can improve performance in wells with silt or where solids deposit on pump components Actuator rod slot is wider for greater clearance between rod and float Now standard on AP4+ models Can be retrofit to existing AP4+ pumps (contact QED Customer Service for details) Standard Float Wide Slot Float

23 23 Accessories to improve performance and reduce maintenance in tough applications Wide-Slot Float with Non-Stick Coating Entire float assembly is coated with a proprietary non-stick coating Greatly reduces build-up of solids on the float, which can extend maintenance intervals Speeds cleaning and reduces chance of damaging float during cleaning Replaces Teflon-wrapped floats for applications with sticky deposits or high dissolved solids Standard on AP4 Ultra; can be retrofit to existing AP4+ pumps contact QED for details Easy Fittings faster and safer Maintenance often requires removing pump tubing Cutting tubing and clamps from barb fittings can be difficult, time consuming, poses a safety risk, and shortens tubing length 2-3 (5-8 cm) each time Easy Fittings are high-flow quick connects with quick-release retainer clips Made of high-quality stainless steel alloys with double Viton O-ring seals Saves valuable field time and cost LESS than conventional quick-connect fittings

24 24 Stand tubes for pump testing A stand tube should be used to verify that a pump is working before you send it back down the well to avoid pulling it again if it s still not working You can make a stand tube from a piece of 4-inch diameter PVC pipe or well casing about 5 feet long, with a flat threaded cap or plug at the bottom PVC is very inexpensive, holds up well to most cleaning solutions and leachates A stand tube can save HOURS of lost time if you find that a pump isn t working properly before it s installed Pump service life expectations Pump service life is dependent on operating conditions of each well (chemistry, temperature, solids, etc.) and proper materials selection for the application The biggest factor you can control is pump maintenance. Many QED pumps have been in use for years and are still operational due to regular maintenance 90% of all pump maintenance is cleaning, not repairs

25 25 Some applications are a bit more challenging than others, but with proper selection of pump model and materials, good installation practices and adequate preventative maintenance, air-powered automatic pumps can handle some of the toughest pumping application seen at landfill and remediation sites with longer service life than other pump designs. Questions? QED Environmental Systems, Inc. info@qedenv.com Toll-Free Numbers Ann Arbor, MI: San Leandro, CA: Website

Troubleshooting and Maintenance of Air-Powered Pumping Systems

Troubleshooting and Maintenance of Air-Powered Pumping Systems Troubleshooting and Maintenance of Air-Powered Pumping Systems David Kaminski QED Environmental Systems Inc. Ann Arbor, MI / San Leandro, CA Copyright QED Environmental Systems, Inc. 2015; all rights reserved.

More information

Troubleshooting and Maintenance of Air-Powered Pumping Systems

Troubleshooting and Maintenance of Air-Powered Pumping Systems Troubleshooting and Maintenance of Air-Powered Pumping Systems David Kaminski QED Environmental Systems Inc. Ann Arbor, MI / San Leandro, CA Copyright QED Environmental Systems, Inc. 2013; all rights reserved.

More information

Innovative Wellhead Products for Landfill Gas Management

Innovative Wellhead Products for Landfill Gas Management Innovative Wellhead Products for Landfill Gas Management QED Environmental Systems Inc. Ann Arbor, Michigan - San Leandro, California Copyright QED Environmental Systems, Inc. 2013; all rights reserved.

More information

Landfill Gas Well Pump Evaluation Guide

Landfill Gas Well Pump Evaluation Guide Landfill Gas Well Pump Evaluation Guide From Manufacturer of AutoPump Landfill Pumps P/N 2348B Rev. 7-7-10 What to look for in a landfill gas well pump. Standard 5-Year Warranty. Superior Landfill Gas

More information

Sample Pro 3/4" Portable MicroPurge Pump. User's Guide P/N REV The World Leader in Air Powered Pumps

Sample Pro 3/4 Portable MicroPurge Pump. User's Guide P/N REV The World Leader in Air Powered Pumps PATENT PENDING Pro 3/4" Portable MicroPurge Pump User's Guide P/N 959 REV. -8-03 The World Leader in Air Powered For Remediation, Landfills and Ground Water Sampling Ground water Sampling Remediation,

More information

Patent Pending EXTENDED-DUTY PISTON PUMP

Patent Pending EXTENDED-DUTY PISTON PUMP TM Patent Pending EXTENDED-DUTY PISTON PUMP O p e r a t i o n & I n s t a l l a t i o n M a n u a l P/N 95222 Rev. 9-29-9 4 2 6 psi 9 1 12 16 14 2 4 6 8 1 INCHES W.C. 4 2 6 N psi IN 1 12 16 14 EXTENDED-DUTY

More information

SLM - Sealing Liquid Monitor INSTRUCTIONS FOR USE

SLM - Sealing Liquid Monitor INSTRUCTIONS FOR USE INSTRUCTIONS FOR USE 1/8 1 INSTALLATION SLM - Sealing Liquid Monitor INSTRUCTIONS FOR USE 1.1 Mounting The SLM has a mounting plate for simple installation. The SML can be mounted using a bolt already

More information

Injector. General Information CAUTION. Use only the specified injector for the engine.

Injector. General Information CAUTION. Use only the specified injector for the engine. Page 1 of 32 006-026 Injector General Information CAUTION Use only the specified injector for the engine. All engines use closed nozzle, hole-type injectors. However, the injectors can have different part

More information

SRX R. Remediation Pumps. Simply Reliable

SRX R. Remediation Pumps. Simply Reliable SRX R Remediation Pumps Simply Reliable The SRX pump is based on a simple, innovative design and built with fi eld-proven components. The result: a reliable pump to meet the demands of your remediation

More information

SRX. Remediation Pumps. Simply Reliable

SRX. Remediation Pumps. Simply Reliable SRX Remediation Pumps Simply Reliable The SRX is a based on a simple, innovative design and built with fi eld-proven components. The result: a reliable pump to meet the demands of your remediation site.

More information

3M Overhaul Service Kit

3M Overhaul Service Kit SERVICE INSTRUCTIONS FOR 3M 12,000 RPM 5 in. (127 mm) and 6 in. (150 mm) RANDOM ORBITAL SANDERS 3M Overhaul Service Kit The part number 20347, 3M Overhaul Service Kit, contains all the replacement parts

More information

3M Overhaul Service Kit

3M Overhaul Service Kit SERVICE INSTRUCTIONS FOR 3M 12,000 RPM 3 in. (77 mm) RANDOM ORBITAL SANDERS 3M Overhaul Service Kit The part number 20346, 3M Overhaul Service Kit, contains all the replacement parts that naturally wear

More information

Backpack Sprayer. Use and Care Manual

Backpack Sprayer. Use and Care Manual Backpack Sprayer Use and Care Manual BACKPACK SPRAYER CAUTION: Read and follow all instructions Do Not Return This Backpack To The Store For Help, Information or Parts, Call : 1-800-311-9903 The Fountainhead

More information

What s Eating Your Pump?

What s Eating Your Pump? What s Eating Your Pump? Selecting Submersible Pumps for Landfill Leachate/Condensate Removal David Kaminski QED Environmental Systems Inc. Copyright QED Environmental Systems, Inc. 2007, 2008, 2009; all

More information

WARNING Carefully Read These Instructions Before Use

WARNING Carefully Read These Instructions Before Use DO NOT RETURN THIS SPRAYER TO STORE Call: 1-800-950-4458 Backpack Sprayer Use and Care Manual Manufactured for Northern Tool + Equipment Co., Inc. WARNING Carefully Read These Instructions Before Use Model

More information

PCC O P E R A T I O N S. Pump Cycle Counter M A N U A L. Environmental Systems

PCC O P E R A T I O N S. Pump Cycle Counter M A N U A L. Environmental Systems O P E R A T I O N S Environmental Systems PCC Pump Cycle Counter M A N U A L PO Box 3726 Ann Arbor, Michigan 48106-3726 (800) 624-2026 North America Only (734) 995-2547 Tele. (734) 995-1170 Fax info@qedenv.com

More information

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE DEFENDER SERIES 5 Gallon, Double Walled, Field Replaceable Spill Container Model 705-550 Series INSTALLATION, OPERATION, & MAINTENANCE Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel:

More information

Installation Instructions Supertop NX Twill

Installation Instructions Supertop NX Twill Installation Instructions Supertop NX Twill Vehicle Application: Jeep Wrangler Unlimited 2007 Current Part Number: 54823 www.bestop.com - We re here to help! Visit our web site and click on Ask a Question.

More information

WEBER CARBURETOR TROUBLESHOOTING GUIDE

WEBER CARBURETOR TROUBLESHOOTING GUIDE This guide is to help pinpoint problems by diagnosing engine symptoms associated with specific vehicle operating conditions. The chart will guide you step by step to help correct these problems. For successful

More information

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance 119 Overview Warning: This bulletin should be used by experienced personnel as a guide to the installation and maintenance

More information

Installation Instructions Supertop NX

Installation Instructions Supertop NX Installation Instructions Supertop NX Vehicle Application: Jeep Wrangler JK 2 Door 2007 Current Part Number: 54722 www.bestop.com - We re here to help! Visit our web site and click on Ask a Question. Click

More information

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES APCO ASR-400/450 SEWAGE AIR RELEASE VALVES Instruction D12005 December 2012 Instructions These instructions provide installation, operation and maintenance information for the APCO ASR- 400/450 Sewage

More information

Insta-Valve 250 Patriot TM

Insta-Valve 250 Patriot TM Insta-Valve 250 Patriot TM 4-12 Nominal Size Installation Instructions for use with the Hydra-Core Pipewall Sampling Kit IV250MAN 4-12 IV 250 PWSK v1.93 Revised 07/11/2018 Covered by United States Patent

More information

Fluid-O-Tech ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL

Fluid-O-Tech ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL Fluid-O-Tech PUMP TECHNOLOGY AT ITS BEST WWW.FLUID-O-TECH.COM Office: 161 Atwater St., Plantsville, CT 06479 Phone: (860) 276-9270 Fax: (860) 620-0193 ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL 08/09 Ed.,

More information

NILFISK BA 500 Service Manual

NILFISK BA 500 Service Manual NILFISK BA 500 Service Manual Model 66324400 12/94 Form Number 043023 TABLE OF CONTENTS Batteries...21 Brush Drive Belt Adjustment Or Replacement...7 Brush Drive Motor - Carbon brush Inspection... 8 Brush

More information

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components Introduction The Pro Manifolds with Integrated adaptor are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options

More information

Installation Instructions Supertop NX

Installation Instructions Supertop NX Installation Instructions Supertop NX Vehicle Application: Jeep Wrangler Unlimited 2007 Current Part Number: 54723 www.bestop.com - We re here to help! Visit our web site and click on Ask a Question. Click

More information

2. Disconnect negative battery cable to avoid possible fuel discharge if an accidental attempt is made to start the engines.

2. Disconnect negative battery cable to avoid possible fuel discharge if an accidental attempt is made to start the engines. PART #25001 LT1 Adjustable Fuel Pressure Regulator, 1994-1997 PACKING LIST Before installation, use this check list to make sure all necessary parts have been included. ITEM QTY CHECK PART NUMBER DESCRIPTION

More information

Installation Instructions Sunrider for Hardtop

Installation Instructions Sunrider for Hardtop Installation Instructions Sunrider for Hardtop Installation Instructions Sunrider for Hardtop Vehicle Application: Jeep Wrangler / Wrangler Unlimited 2007- current Part Number 52450 Installation Tips Before

More information

M-3025CB-AV Fuel Pump

M-3025CB-AV Fuel Pump SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...

More information

Crispin Valves Operating Guide. Crispin

Crispin Valves Operating Guide. Crispin Crispin Valves Operating Guide Crispin Since 1905 Crispin Multiplex Manufacturing Co. 600 Fowler Avenue Berwick, PA 18603 1-800-AIR-VALV T: (570) 752-4524 F: (570) 752-4962 www.crispinvalve.com sales@crispinvalve.com

More information

CUSTOM COMBINATION AIR VALVE

CUSTOM COMBINATION AIR VALVE INSTALLATION / OPERATION / MAINTENANCE CUSTOM COMBINATION AIR VALVE INTRODUCTION This manual will provide you with the information to properly install and maintain this valve to ensure a long service life.

More information

SLOPE INDICATOR Geotechnical Instruments

SLOPE INDICATOR Geotechnical Instruments SLOPE INDICATOR Geotechnical Instruments Environmental Products Materials Testing Equipment Profile Offices in the USA, Canada, Australia and China. Manufacturing in Stone Mountain, GA. and Mukilteo, WA.

More information

Oil Drain Plug Repair Kit. 5. Boring tool (drill bit) 1. Oil cap with regulator. 6. Alignment tool. 2.

Oil Drain Plug Repair Kit. 5. Boring tool (drill bit) 1. Oil cap with regulator. 6. Alignment tool. 2. Oil Drain Plug Repair Kit Part #: AGA-ODP-12-14-K 1. Oil cap with regulator 2. Oil drain plugs 3. Air supply hose with valve 4. Debris shield 5. Boring tool (drill bit) 6. Alignment tool 7. Thread forming

More information

Technical Data P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP SD 9952B

Technical Data P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP SD 9952B Technical Data SD 9952B SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NEW YORK, 12586-2035 P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP Pressures To 250 PSIG (20.7 barg) Temperatures

More information

I. Safety Requirement WARNING. ATV/UTV Winch

I. Safety Requirement WARNING. ATV/UTV Winch 1 2 ATV/UTV Winch Thank you for purchasing a COMEUP Winch. This manual covers operation and maintenance of the winch. All information in this publication is based on the latest production information available

More information

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C D E M A SINGLE-STAGE MODELS SINGLE-STAGE MODELS 1. PARTS A. Injector B. Backup washer (Models 204C & smaller). C. Ceramic Weight. D. Tubing 8 long w/ foot strainer. E. Three brass nozzle bushings Metering

More information

36-1 DP PLEASE READ BEFORE USING THIS EQUIPMENT

36-1 DP PLEASE READ BEFORE USING THIS EQUIPMENT 36-1 DP PLEASE READ BEFORE USING THIS EQUIPMENT DP 36-1 Assembly Instructions PLEASE READ INSTRUCTIONS COMPLETELY BEFORE STARTING We thank you for purchasing the DP-36 pressure system. This system has

More information

INSTALLATION TROUBLESHOOTING SUPPLEMENT

INSTALLATION TROUBLESHOOTING SUPPLEMENT TITAN Fuel Tanks INSTALLATION TROUBLESHOOTING SUPPLEMENT For Midship Replacement Fuel Tanks AND Utility Tanks This supplement is intended to provide additional information for installers to aid in simple

More information

Meeting our clients needs for over 50 years.

Meeting our clients needs for over 50 years. P R O D U C T S C A T A L O G Meeting our clients needs for over 50 years. Over half a century ago, a pipe and fitting specialist noticed that too many field workers were sustaining injuries while trying

More information

1 CONDIMENT DISPENSING SYSTEMS MODELS MCD-1 & MCD-2

1 CONDIMENT DISPENSING SYSTEMS MODELS MCD-1 & MCD-2 1 CONDIMENT DISPENSING SYSTEMS MODELS MCD-1 & MCD-2 THIS EQUIPMENT CHAPTER SHOULD BE INSERTED IN THE EQUIPMENT MANUAL MANUFACTURED FOR McDONALD S BY PERFECTION EQUIPMENT, INC. 4259 LEE AVENUE GURNEE, ILLINOIS

More information

CALIFORNIA TRIMMER MOWER MAINTENANCE MANUAL

CALIFORNIA TRIMMER MOWER MAINTENANCE MANUAL CALIFORNIA TRIMMER MOWER MAINTENANCE MANUAL 2 Table of Contents Section 1: General Information Page Handle Assembly Instructions 4 Maintenance All Models 6 Oil Change Procedures All Models 9 Height Adjustment

More information

AP4/SPG4 Combo Pump. AutoPump/Speci c Gravity Skimmer Controllerless System (for 4-inch wells or larger)

AP4/SPG4 Combo Pump. AutoPump/Speci c Gravity Skimmer Controllerless System (for 4-inch wells or larger) O P E R A T I O N S M A N U A L AutoPump/Speci c Gravity Skimmer Controllerless System (for 4-inch wells or larger) PO Box 3726 6095 Jackson Road Ann Arbor, Michigan 48106-3726 (800) 624-2026 North America

More information

Installation Guidelines

Installation Guidelines JUSV4-K (metal lever handle) & GUSVR (rough) JUSV4-K (white porcelain lever handle) & GUSVR (rough) JUSV43-K (black porcelain lever handle-mto) & GUSVR (rough) 5 " Shower Outlet Tub Outlet 3 "± " IMPORTANT

More information

INSTALLATION AND MAINTENANCE OF TOP LOADING ARM

INSTALLATION AND MAINTENANCE OF TOP LOADING ARM INSTALLATION AND MAINTENANCE OF TOP LOADING ARM D TABLE OF CONTENTS 1. INTRODUCTION 04 2. SPECIFICATION OF THE REDLANDS LOADING ARM 04 3. INSTALLING THE LOADING ARM 3.1. Installation Procedures 05 4.

More information

The Chameleon Trac II Patent Pending M-Series User s Manual

The Chameleon Trac II Patent Pending M-Series User s Manual The Chameleon Trac II Patent Pending M-Series User s Manual YOU MAY ALSO VIEW OUR GENERAL OPERATION VIDEO ONLINE AT: www.marionbrush.com Please read entire manual prior to using this system. Page 1 The

More information

Troubleshooting Guide for Pumps ATD ATD ATD5289

Troubleshooting Guide for Pumps ATD ATD ATD5289 PROBLEM: Your pump does not work? There are Three Basic Problems! Troubleshooting Guide for Pumps ATD5217 - ATD5219 - ATD5289 Air Motor Operates but nothing comes out. This is the most common problem.

More information

SECTION 4A BRAKE SYSTEM TABLE OF CONTENTS

SECTION 4A BRAKE SYSTEM TABLE OF CONTENTS SECTION 4A BRAKE SYSTEM TABLE OF CONTENTS Description and Operation... 4A-2 Braking System Testing... 4A-2 Hydraulic Brake System... 4A-2 Brake Pedal... 4A-2 Master Cylinder... 4A-2 Brake Booster... 4A-3

More information

TREASURE VALLEY IRRIGATION CONFERENCE

TREASURE VALLEY IRRIGATION CONFERENCE TREASURE VALLEY IRRIGATION CONFERENCE CORBY GARRETT AQUA IRRIGATION Four Rivers Cultural Center Ontario, Oregon December 14, 2017 DRIP IRRIGATION MAINTENANCE DRIP IRRIGATION MAINTENANCE SYSTEM STARTUP

More information

Table of Contents Visual Inspection and Neutralizing... 3 Disassembly

Table of Contents Visual Inspection and Neutralizing... 3 Disassembly 1 Table of Contents Visual Inspection and Neutralizing... 3 Disassembly... 3... 4... 4 Cleaning... 4 Inspection... 4 Reconditioning of Valve Seats... 5 Lapping Procedures... 5 Lapping Blocks... 5 Lapping

More information

Installation Instructions

Installation Instructions Preparing your vehicle to install your brake system upgrade 1. Rack the vehicle. 2. If you don t have a rack, then you must take extra safety precautions. 3. Choose a firmly packed and level ground to

More information

Section 10 Chapter 17

Section 10 Chapter 17 Section 10 Chapter 17 24 Valve, 8.3 Liter Engine Air Intake System Note: All coding used in the 8.3 Liter and 9 Liter engine manuals are Cummins engine codes. These engine codes have no meaning to New

More information

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

HIGH PRESSURE CONTROL VALVE PISTON BALANCED PISTON BALANCED All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be

More information

Maintenance Information

Maintenance Information 45761848 Edition 3 February 2014 Air Die Grinder AC4A, SC4A and XC4A Series Maintenance Information Save These Instructions Product Safety Information WARNING Failure to observe the following warnings,

More information

Page 1 of 19. Part# /10/2006

Page 1 of 19. Part# /10/2006 Part# 1002733-01 10/10/2006 This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly and keep for future reference INSTRUCTIONS

More information

AIR CLEANER GENERAL REMOVAL. 1CAUTION Do not run engine without filter element in place. Debris could be drawn into the engine causing damage.

AIR CLEANER GENERAL REMOVAL. 1CAUTION Do not run engine without filter element in place. Debris could be drawn into the engine causing damage. AIR CLEANER GENERAL The air cleaner prevents foreign material from entering the carburetor and engine by trapping airborne dust and dirt in the filter element. Service air cleaner filter element every

More information

User Manual. MVP IV Series Groundwater Pumps. Version 2.2. Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA USA

User Manual. MVP IV Series Groundwater Pumps. Version 2.2. Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA USA MVP IV Series Groundwater Pumps User Manual Version 2.2 Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA 30087 USA Phone: 800-837-0864 or +1.770.465.7557 Fax: 770.465.7447 e-mail: solutions@durhamgeo.com

More information

LEAK TEST PROCEDURE MRTALPCH611LDC REMOTE READY LIFTERS W/ 3 BUTTON CONTROL APPLICABLE TO LIFTERS WITH SERIAL NUMBERS GREATER THAN #

LEAK TEST PROCEDURE MRTALPCH611LDC REMOTE READY LIFTERS W/ 3 BUTTON CONTROL APPLICABLE TO LIFTERS WITH SERIAL NUMBERS GREATER THAN # LEAK TEST PROCEDURE MRTALPCH611LDC REMOTE READY LIFTERS W/ 3 BUTTON CONTROL APPLICABLE TO LIFTERS WITH SERIAL NUMBERS GREATER THAN # 20100742 TESTING AND MAINTENANCE MUST BE DONE BY A QUALIFIED PERSON

More information

INSTALLATION & USER S GUIDE

INSTALLATION & USER S GUIDE REKLUSE MOTOR SPORTS The Rekluse Core EXP Kit with Adjustable Slave Cylinder INSTALLATION & USER S GUIDE Doc ID: 191-7704A Doc Rev: 102915 OVERVIEW This kit replaces the OEM core clutch components including

More information

Installation Instructions for the F2B Pedal Bracket Kit

Installation Instructions for the F2B Pedal Bracket Kit Installation Instructions for the F2B Pedal Bracket Kit A. General Information 1. Before you begin, familiarize yourself with this installation procedure. It is assumed that the installer is an experienced

More information

Cla-Val. Service Training Manual. Simple solutions plus learning with a purpose

Cla-Val. Service Training Manual. Simple solutions plus learning with a purpose Cla-Val Service Training Manual Simple solutions plus learning with a purpose 5 Application Series Section General Identify What Valve You Have 5-1 Rate of Flow 40 Series 5-2 Pressure Relief 50 Series

More information

OWNERS SERVICE MANUAL INSTALLATION, OPERATING AND SERVICING. Model SGMH 781K. Model SGMH 783K

OWNERS SERVICE MANUAL INSTALLATION, OPERATING AND SERVICING. Model SGMH 781K. Model SGMH 783K OWNERS SERVICE MANUAL INSTALLATION, OPERATING AND SERVICING Model SGMH 781K ABC (AMMONIUM PHOSPHATE BASE) Model SGMH 783K PK (Potassium Bicarbonate) RECHARGE FIRE EXTINGUISHERS IMMEDIATELY AFTER ANY USE

More information

Heavy Duty Sprayer Owners Manual Model MS-O

Heavy Duty Sprayer Owners Manual Model MS-O Heavy Duty Sprayer Owners Manual Model MS-O Table of Contents Warranty 4 Warning 5 Assembly and Preparation 6 Operation 7 Cleaning and Storage 7 Standard Spray Gun & Parts List 8 Trigger Style Spray Gun

More information

Regulated Hose Supply Installation, Operation & Maintenance Manual

Regulated Hose Supply Installation, Operation & Maintenance Manual Regulated Hose Supply Installation, Operation & Maintenance Manual For Models: BA-MS-320-00 BA-MS-320-05 BA-MS-320-20 BA-MS-325-00 BA-MS-325-05 BA-MS-325-20 BA-SFS-320-000 BA-SFS-320-012 BL-005 1/30/2007

More information

STEERING COLUMN, LOWER STEERING SHAFT, AND STEERING GEAR BOX ALIGNMENT

STEERING COLUMN, LOWER STEERING SHAFT, AND STEERING GEAR BOX ALIGNMENT Please note: this is a draft document it has not been validated. If you choose to use it please check all steps and, if you find something wrong or have suggestions, contact Rob Mueller. This was presented

More information

Operation and Maintenance Manual Model.75,, 3, 5, 8, 0, 0, 5, 35, 50 http://www.torsionx.com Use the MaxDrv Series Square Drive Torque Wrench Model.75,, 3, 5, 8, 0, 0, 5, 35, 50 to install and remove threaded

More information

Instruction Manual Part No

Instruction Manual Part No U O asics MODEL MP30 Draw Down Meter PATENT PENDING Instruction Manual Part No. 95180 5-31-07 P.O. Box 3726 Ann Arbor, MI 48106-3726 USA 1-800-624-2026 Fax (734) 995-1170 info@qedenv.com www.qedenv.com

More information

Mini Pump Installation, Operation & Maintenance Manual. For Models: BA-MS-633

Mini Pump Installation, Operation & Maintenance Manual. For Models: BA-MS-633 Mini Pump Installation, Operation & Maintenance Manual For Models: BA-MS-633 BL-309 6/08/2012 General Information & Precautions This publication provides detailed instructions for installing the single

More information

Table of Contents Illustrations

Table of Contents Illustrations Principals of Operation Inspection & Troubleshooting Principles of Operation Inspection & Troubleshooting Form No. F 1031 Section 1000 Issue Date 09/19/94 Rev. Date 02/07/07 Table of Contents Illustrations

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC PROXIMITY DUAL FLUSH TOILET FLUSH VALVE. /. GPF,.8/. GPF Certified to comply with ASME A.9.M 00 AS America, Inc. M90 REV.. Exposed Flushometer for -/" Top Spud Bowls

More information

Instruction Manual. Part No Rev 2. A Graco Company

Instruction Manual. Part No Rev 2. A Graco Company Instruction Manual Part No. 95312 8-14-2017 Rev 2 A Graco Company QED Environmental Systems 2355 Bishop Circle West Dexter, MI 48130 US Toll Free: 800-624-2026 Tel: +1 (734) 995-2547 Fax: +1 (734) 995-1170

More information

OWNER S MANUAL. Model: FS-ATV-15 ( ) (15 Gallon Lawn & Garden/ATV Sprayer) Technical Specifications. Assembly Instructions. General Information

OWNER S MANUAL. Model: FS-ATV-15 ( ) (15 Gallon Lawn & Garden/ATV Sprayer) Technical Specifications. Assembly Instructions. General Information OWNER S MANUAL Model: FS-ATV-15 (5301169) (15 Gallon Lawn & Garden/ATV Sprayer) Technical Specifications 15 Gal. Corrosion-Resistant Polyethylene Tank 12 Volt Diaphragm Pump, 1.8 g.p.m. 60 psi Spot Sprayer

More information

EasySelect-Cup Manual Powder Gun

EasySelect-Cup Manual Powder Gun E Operating Instructions and Spare parts list EasySelect-Cup Manual Powder Gun EasySelect-Cup 27 28 EasySelect-Cup Table of Contents Safety rules EasySelect-Cup Manual Powder gun...........................................

More information

Electric Fuel Pump FPM

Electric Fuel Pump FPM INSTRUCTION MANUAL Electric Fuel Pump FPM S1590, Rev B LISTED MOTOR FPM-12, FPM-24, FPM-115, FPM-220 Congratulations on purchase of this World Class Electric Fuel Pump! Elbow This is an Electric Fuel Pump.

More information

Pypes Polished Shorty Headers (05-10 V6):

Pypes Polished Shorty Headers (05-10 V6): Pypes Polished Shorty Headers (05-10 V6): Introduction: The kit comes complete with replacement hardware and gaskets and can be easily done in your driveway. The hardware supplied for install includes

More information

February 26, ch.12.notebook. Ch. 12. Preventative Maintenance and Troubleshooting. Feb 23 5:03 PM

February 26, ch.12.notebook. Ch. 12. Preventative Maintenance and Troubleshooting. Feb 23 5:03 PM Ch. 12 Preventative Maintenance and Troubleshooting Feb 23 5:03 PM 1 Why PM? preventive maintenance certain maintenance tasks must be performed regularly to keep an engine working properly helps premature

More information

OWNER S MANUAL Model: TR-40-EX ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly)

OWNER S MANUAL Model: TR-40-EX ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly) OWNER S MANUAL Model: TR-40-EX (5301338) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly) Technical Specifications 40 Gal. Corrosion-Resistant Polyethylene Tank 12 Volt Diaphragm Pump,

More information

To ensure proper installation, digital pictures with contact information to before startup.

To ensure proper installation,  digital pictures with contact information to before startup. Check List for Optimal Filter Performance? There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and 2 valve should have a 3 waste line. Do not use rubber hosing or

More information

NOTE: Visit our website at for video repair procedures, under the Tools section.

NOTE: Visit our website at   for video repair procedures, under the Tools section. Repair Instructions Hypro Repair Tools: Tool Box No. 3010-0168 1/4" Allen Wrench No. 3020-0008 Support Bars (2) No. 3010-0064 Port Brush No. 3010-0066 1/16" Allen Wrench No. 3020-0009 Brush Holder No.

More information

2005 RADIUM/ METEL SHOCK SERVICE MANUAL

2005 RADIUM/ METEL SHOCK SERVICE MANUAL 2005 RADIUM/ METEL SHOCK SERVICE MANUAL PN 042132,. '05 RADIUM/ METEL SHOCK SERVICE MANUAL Page 1 PN 042132 2005 RADIUM/ METEL SHOCK SERVICE MANUAL INDEX Section Description Page 1 INTRODUCTION 3 2 SETUP,

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM) INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM) IOM-1088 03-16 Model 1088 Vacu-Gard Blanketing Valve ISO Registered Company SECTION I I. DESCRIPTION AND SCOPE The Model 1088 Vacu-Gard is a tank blanketing

More information

GENESIS COUPE(BK) > 2010 > G 3.8 DOHC > Steering System

GENESIS COUPE(BK) > 2010 > G 3.8 DOHC > Steering System GENESIS COUPE(BK) > 2010 > G 3.8 DOHC > Steering System Steering System > General Information > Specifications Specifications Steering gear Oil pump Steering angle Power steering oil Item Specification

More information

BRAKES. Section III REAR AXLE DATA AND SPECIFICATIONS HAND BRAKE CHRYSLER SERVICE MANUAL BRAKES 17

BRAKES. Section III REAR AXLE DATA AND SPECIFICATIONS HAND BRAKE CHRYSLER SERVICE MANUAL BRAKES 17 BRAKES 17 There is no basic design change in the rear axle and sure grip differential except the larger diameter pinion shaft is now used on all models for 1959. The Service Procedures will remain the

More information

Oil Purification Systems, Inc.

Oil Purification Systems, Inc. Oil Purification Systems, Inc. Installation Instructions for Mack Trucks Document Part Number I-003 Document Edition Number 1.0 Edition Release Date August 2006 Table of Contents Table of Contents Safety

More information

MASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL

MASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL MASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL INSTALLATION: CHOOSING THE LOCATION: Locate the coalescer as near to the intended point of use as possible. Avoid high

More information

Installation & Operating Manual

Installation & Operating Manual Installation & Operating Manual VN Series Non-Clog Pumps Congratulations On Your Choice In Purchasing This Webtrol Pump 10/15 Edition Its Quality is unsurpassed in material and workmanship and has been

More information

Operating Manual. Hydra S (W)VAC

Operating Manual. Hydra S (W)VAC Operating Manual Pop up Sprinkler Hydra S (W)VAC PERROT TDP053e.doc Rev. 16.06.2015 Page 1 / 21 Contents 1 SAFETY... 3 1.1 HOW INSTRUCTIONS ARE MARKED IN THIS MANUAL... 3 1.2 HAZARDS OF IGNORING SAFETY

More information

Installation Instructions

Installation Instructions Installation Instructions SELECTRONIC DC POWERED PROXIMITY EXPOSED URINAL FLUSH VALVE 0., 0., 0. &.0 GPF Certified to comply with ASME A.9. 0 AS America, Inc. Exposed Flushometer for /" Top Spud Urinals

More information

!"#! $ #%##&#! '!( ) *!& ##& + #%#&, *!!#" ## -. /%# 0 .!!1!/ 2#1! $ 3 ) "4 + !6%!! -3!!!5%. 7 $* #8#%# # )

!#! $ #%##&#! '!( ) *!& ##& + #%#&, *!!# ## -. /%# 0 .!!1!/ 2#1! $ 3 ) 4 + !6%!! -3!!!5%. 7 $* #8#%# # ) !#! #%##&#! '! *!& ##& + #%#&, *!!# ## -. /%# 0 %#.!!1!/ 2#1! 3 4 + %!5!#,!6%!! -3!!!5%. 7 * #8#%# # 75/ o o!3, o 9! - o!!: 0 o. : ' o /2# ' o ;;!! ''. ' !# % # &'& &*+,, &# - ' #. %&'/!#,,/+ & %#!6&!!%#%

More information

RAMPAGE POWER LIFT RAMP

RAMPAGE POWER LIFT RAMP RAMPAGE POWER LIFT RAMP INSTALLATION AND OPERATING INSTRUCTIONS (3/10/07) The Rampage Power Lift Ramp is the fast, easy, and safe way to load a motorcycle into a truck. One person can load or unload a

More information

TABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color

TABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color Blend Safe II Dispensing System is a modular, locking dispensing system that allows user to dispense chemicals safely, control dispenser inventory and has the flexibility in the field to meet changing

More information

Gas Engine overheat diagnosis

Gas Engine overheat diagnosis Gas Engine overheat diagnosis Introduction... 2 Six Step Troubleshooting Method... 3 Diagnostic Tips... 4 Clear Hose Testing Equipment... 5 Clear Hose Setup (Pump)... 6 Clear Hose Setup (Engine)... 7 Gauge

More information

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013. 172-65177M-02 (TATSU2) 7 August 2013 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Air Trap TATSU2 Copyright 2013 by TLV CO., LTD. All rights reserved 1 Contents

More information

Installation, Operation & Maintenance Manual. For Pro-Fill kits with part numbers beginning in BG

Installation, Operation & Maintenance Manual. For Pro-Fill kits with part numbers beginning in BG Installation, Operation & Maintenance Manual For Pro-Fill kits with part numbers beginning in BG BL-175 6/26/2009 General Information & Precautions This publication provides detailed instructions for installing

More information

Installation Instructions / Warranty

Installation Instructions / Warranty Installation Instructions / Warranty Citterio 39136XX1 39156XX1 Citterio 39236XX1 Axor Citterio Widespread Lav Mixer 39136XX1 Axor Citterio Bidet Mixer 39236XX1 39136XX1 User instructions Turn the right

More information

WATCH GUARD 440 SERIES FLOAT VALVES INSTALLATION INSTRUCTIONS MODELS: T, TX, T, BT,

WATCH GUARD 440 SERIES FLOAT VALVES INSTALLATION INSTRUCTIONS MODELS: T, TX, T, BT, WATCH GUARD 440 SERIES FLOAT VALVES INSTALLATION INSTRUCTIONS MODELS: 440-22T, 440-22TX, 440-23T, 440-23BT, 440-24 Overview The Watch Guard 440 Series of float valves fills and maintains fluids in reservoirs.

More information

Vane Replacement & Complete Rebuild Manual

Vane Replacement & Complete Rebuild Manual National Vacuum Equipment Vane Replacement & Complete Rebuild Manual 607 Challenger Series Rotary Vane Vacuum Pumps MADE IN USA 2013 National Vacuum Equipment, Inc. Revision: 5 (Release) March 2013 No

More information

Wastewater Combination Air Valve. Operation, Maintenance and Installation Manual

Wastewater Combination Air Valve. Operation, Maintenance and Installation Manual Manual No. WCAV-OM1-1 Wastewater Combination Air Valve Operation, Maintenance and Installation Manual INTRODUCTION... 2 RECEIVING AND STORAGE... 2 DESCRIPTION OF OPERATION... 2 INSTALLATION... 3 VALVE

More information

Remove utility bag from plastic and install onto pivot arm with attached straps. Install utility bag with zippers facing away from machine.

Remove utility bag from plastic and install onto pivot arm with attached straps. Install utility bag with zippers facing away from machine. Owner s Manual Packing List: C3XP Unit Spray gun w/ 2 settings 12-volt battery Telescoping handle Removable Cleaning Caddy Pivot arm Utility Bag 10 Gallon water reservoir (integral) 17 ft. discharge hose

More information

4 - Way Control 4 - Way Control 4 - Way Control with lock

4 - Way Control 4 - Way Control 4 - Way Control with lock INSTALLATION / OPERATION / MAINTENANCE 1. DESCRIPTION MODEL 0-02 (Full Internal Port) Powertrol Valve This manual contains information for installation, operation and maintenance of the Cla-Val Co. 0-02

More information